1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
|
STP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, Counter32, TimeTicks, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
gbnL2 FROM ADMIN-MASTER-MIB;
stpMib MODULE-IDENTITY
LAST-UPDATED "9904230031Z" -- April 23, 1999
ORGANIZATION "admin Inc."
CONTACT-INFO
"admin
E-mail: "
DESCRIPTION "STP module management."
REVISION "9905130000Z" -- May 13, 1999
DESCRIPTION "Initial Version"
::= { gbnL2 3 }
stpMIBObjects OBJECT IDENTIFIER ::= { stpMib 1 }
stpDot1dStp OBJECT IDENTIFIER ::= { stpMIBObjects 1 }
-- All representations of MAC addresses in this MIB Module
-- use, as a textual convention (i.e. this convention does
-- not affect their encoding), the data type:
-- MacAddress ::= OCTET STRING (SIZE (6)) a 6 octet address
-- in the
-- "canonical"
-- order
-- defined by IEEE 802.1a, i.e., as if it were transmitted
-- least significant bit first, even though 802.5 (in
-- contrast to other n802.x protocols) requires MAC
-- addresses to be transmitted most significant bit first.
--
-- 16-bit addresses, if needed, are represented by setting
-- their upper 4 octets to all 0's, i.e., AAFF would be
-- represented as 00000000AAFF.
-- Similarly, all representations of Bridge-Id in this MIB
-- Module use, as a textual convention (i.e. this
-- convention does not affect their encoding), the data
-- type:
BridgeId ::= OCTET STRING (SIZE (8)) -- the
-- Bridge-Identifier
-- as used in the
-- Spanning Tree
-- Protocol to uniquely identify a bridge. Its first two
-- octets (in network byte order) contain a priority
-- value and its last 6 octets contain the MAC address
-- used to refer to a bridge in a unique fashion
-- (typically, the numerically smallest MAC address
-- of all ports on the bridge).
-- Several objects in this MIB module represent values of
-- timers used by the Spanning Tree Protocol. In this
-- MIB, these timers have values in units of hundreths of
-- a second (i.e. 1/100 secs).
-- These timers, when stored in a Spanning Tree Protocol's
-- BPDU, are in units of 1/256 seconds. Note, however,
-- that 802.1D-1990 specifies a settable granularity of
-- no more than 1 second for these timers. To avoid
-- ambiguity, a data type is defined here as a textual
-- convention and all representation of these timers
-- in this MIB module are defined using this data type. An
-- algorithm is also defined for converting between the
-- different units, to ensure a timer's value is not
-- distorted by multiple conversions.
-- The data type is:
Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds
-- To convert a Timeout value into a value in units of
-- 1/256 seconds, the following algorithm should be used:
--
-- b = floor( (n * 256) / 100)
--
-- where:
-- floor = quotient [ignore remainder]
-- n is the value in 1/100 second units
-- b is the value in 1/256 second units
--
-- To convert the value from 1/256 second units back to
-- 1/100 seconds, the following algorithm should be used:
--
-- n = ceiling( (b * 100) / 256)
--
-- where:
-- ceiling = quotient [if remainder is 0], or
-- quotient + 1 [if remainder is non-zero]
-- n is the value in 1/100 second units
-- b is the value in 1/256 second units
--
-- Note: it is important that the arithmetic operations are
-- done in the order specified (i.e., multiply first, divide
-- second).
-- the stpDot1dStp group
-- Implementation of the dot1dStp group is optional. It is
-- implemented by those bridges that support the Spanning Tree
-- Protocol.
stpDot1dStpProtocolSpecification OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
decLb100(2),
ieee8021d(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of what version of the Spanning
Tree Protocol is being run. The value
'decLb100(2)' indicates the DEC LANbridge 100
Spanning Tree protocol. IEEE 802.1d
implementations will return 'ieee8021d(3)'. If
future versions of the IEEE Spanning Tree Protocol
are released that are incompatible with the
current version a new value will be defined."
::= { stpDot1dStp 1 }
stpDot1dStpPriority OBJECT-TYPE
SYNTAX INTEGER (0..61440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { 32768:all }
The value of the write-able portion of the Bridge
ID, i.e., the first two octets of the (8 octet
long) Bridge ID. The other (last) 6 octets of the
Bridge ID are given by the value of
dot1dBaseBridgeAddress.The value has to be a multiple
of 4096"
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.7"
::= { stpDot1dStp 2 }
stpDot1dStpTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.1.1.3"
::= { stpDot1dStp 3 }
stpDot1dStpTopChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.1.1.3"
::= { stpDot1dStp 4 }
stpDot1dStpDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bridge identifier of the root of the spanning
tree as determined by the Spanning Tree Protocol
as executed by this node. This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.1"
::= { stpDot1dStp 5 }
stpDot1dStpRootCost OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cost of the path to the root as seen from
this bridge."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.2"
::= { stpDot1dStp 6 }
stpDot1dStpRootPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number of the port which offers the
lowest cost path from this bridge to the root
bridge."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.3"
::= { stpDot1dStp 7 }
stpDot1dStpMaxAge OBJECT-TYPE
SYNTAX Timeout (600..4000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second. This is the actual value that this
bridge is currently using."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.4"
::= { stpDot1dStp 8 }
stpDot1dStpHelloTime OBJECT-TYPE
SYNTAX Timeout (100..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.5"
::= { stpDot1dStp 9 }
stpDot1dStpHoldTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.14"
::= { stpDot1dStp 10 }
stpDot1dStpForwardDelay OBJECT-TYPE
SYNTAX Timeout (400..3000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state. The value determines how long the port
stays in each of the Listening and Learning
states, which precede the Forwarding state. This
value is also used, when a topology change has
been detected and is underway, to age all dynamic
entries in the Forwarding Database. [Note that
this value is the one that this bridge is
currently using, in contrast to
stpDot1dStpBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.]"
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.6"
::= { stpDot1dStp 11 }
stpDot1dStpBridgeMaxAge OBJECT-TYPE
SYNTAX Timeout (600..4000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { 2000:all }
The value that all bridges use for MaxAge when
this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
stpDot1dStpBridgeHelloTime. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.8"
::= { stpDot1dStp 12 }
stpDot1dStpBridgeHelloTime OBJECT-TYPE
SYNTAX Timeout (100..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { 200:all }
The value that all bridges use for HelloTime when
this bridge is acting as the root. The
granularity of this timer is specified by 802.1D-
1990 to be 1 second. An agent may return a
badValue error if a set is attempted to a value
which is not a whole number of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.9"
::= { stpDot1dStp 13 }
stpDot1dStpBridgeForwardDelay OBJECT-TYPE
SYNTAX Timeout (400..3000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { 1500:all }
The value that all bridges use for ForwardDelay
when this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
stpDot1dStpBridgeMaxAge. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.10"
::= { stpDot1dStp 14 }
stpPropStpEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { enabled:all }
The enabled/disabled status of STP for the bridge entity."
::= { stpDot1dStp 16 }
-- The Spanning Tree Port Table
stpDot1dStpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF StpDot1dStpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains port-specific information
for the Spanning Tree Protocol."
::= { stpDot1dStp 15 }
stpDot1dStpPortEntry OBJECT-TYPE
SYNTAX StpDot1dStpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information maintained by every port
about the Spanning Tree Protocol state for that
port."
INDEX { stpDot1dStpPort }
::= { stpDot1dStpPortTable 1 }
StpDot1dStpPortEntry ::=
SEQUENCE {
stpDot1dStpPort
INTEGER,
stpDot1dStpPortPriority
INTEGER,
stpDot1dStpPortState
INTEGER,
stpDot1dStpPortEnable
INTEGER,
stpDot1dStpPortPathCost
INTEGER,
stpDot1dStpPortDesignatedRoot
BridgeId,
stpDot1dStpPortDesignatedCost
Integer32,
stpDot1dStpPortDesignatedBridge
BridgeId,
stpDot1dStpPortDesignatedPort
OCTET STRING,
stpDot1dStpPortForwardTransitions
Counter32,
stpDot1dRemoteLoopDetect
INTEGER,
stpDot1wRstpPortTxHoldCount
INTEGER,
stpDot1wRstpPortOperP2p
INTEGER,
stpDot1wRstpPortOperEdge
INTEGER,
stpDot1wRstpPortMcheck
INTEGER,
stpDot1wRstpPortTxTcn
INTEGER,
stpDot1wRstpPortTxConfig
INTEGER,
stpDot1wRstpPortTxRstp
INTEGER,
stpDot1wRstpPortRxTcn
INTEGER,
stpDot1wRstpPortRxConfig
INTEGER,
stpDot1wRstpPortRxRstp
INTEGER,
stpDot1wRstpPortClear
INTEGER,
stpDot1wRstpPortAdminP2p
INTEGER,
stpDot1wRstpPortAdminEdge
INTEGER
}
stpDot1dStpPort OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number of the port for which this entry
contains Spanning Tree Protocol management
information."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.2.1.2"
::= { stpDot1dStpPortEntry 1 }
stpDot1dStpPortPriority OBJECT-TYPE
SYNTAX INTEGER (0..240)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { 128:all }
The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID. The other
octet of the Port ID is given by the value of
stpDot1dStpPort.The value has to be a multiple
of 16"
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.1"
::= { stpDot1dStpPortEntry 2 }
stpDot1dStpPortState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
blocking(2),
listening(3),
learning(4),
forwarding(5),
broken(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port's current state as defined by
application of the Spanning Tree Protocol. This
state controls what action a port takes on
reception of a frame. If the bridge has detected
a port that is malfunctioning it will place that
port into the broken(6) state. For ports which
are disabled (see stpDot1dStpPortEnable), this object
will have a value of disabled(1)."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2"
::= { stpDot1dStpPortEntry 3 }
stpDot1dStpPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The enabled/disabled status of the port."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2"
::= { stpDot1dStpPortEntry 4 }
stpDot1dStpPortPathCost OBJECT-TYPE
SYNTAX INTEGER (1..200000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { 10:all }
The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port. 802.1D-1990 recommends that the
default value of this parameter be in inverse
proportion to the speed of the attached LAN."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.3"
::= { stpDot1dStpPortEntry 5 }
stpDot1dStpPortDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.4"
::= { stpDot1dStpPortEntry 6 }
stpDot1dStpPortDesignatedCost OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The path cost of the Designated Port of the
segment connected to this port. This value is
compared to the Root Path Cost field in received
bridge PDUs."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.5"
::= { stpDot1dStpPortEntry 7 }
stpDot1dStpPortDesignatedBridge OBJECT-TYPE
SYNTAX BridgeId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Bridge Identifier of the bridge which this
port considers to be the Designated Bridge for
this port's segment."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.6"
::= { stpDot1dStpPortEntry 8 }
stpDot1dStpPortDesignatedPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port Identifier of the port on the Designated
Bridge for this port's segment."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.7"
::= { stpDot1dStpPortEntry 9 }
stpDot1dStpPortForwardTransitions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times this port has transitioned
from the Learning state to the Forwarding state."
::= { stpDot1dStpPortEntry 10 }
stpDot1dRemoteLoopDetect OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The LOOP DETECT status of the port."
--端口私有生成树的开启/关闭状态
::= { stpDot1dStpPortEntry 11 }
stpDot1wRstpPortTxHoldCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum number of BPDUs allowed to be transmitted during per helloTime"
--端口在每个helloTime时间内允许发送的最大BPDU数
::= { stpDot1dStpPortEntry 12 }
stpDot1wRstpPortOperP2p OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational point-to-point status of the LAN segment attached to this port"
--端口实际工作的点对点链接状态
::= { stpDot1dStpPortEntry 13 }
stpDot1wRstpPortOperEdge OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational value of the Edge Port parameter"
--端口实际工作的边界端口状态
::= { stpDot1dStpPortEntry 14 }
stpDot1wRstpPortMcheck OBJECT-TYPE
SYNTAX INTEGER {
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"force port into transmitting rstp packets"
--强制端口发送RSTP报文
::= { stpDot1dStpPortEntry 15 }
stpDot1wRstpPortTxTcn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output statistics of TCN packets"
--端口发送的TCN报文个数
::= { stpDot1dStpPortEntry 16 }
stpDot1wRstpPortTxConfig OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output statistics of CONFIG packets"
--端口发送的CONFIG报文个数
::= { stpDot1dStpPortEntry 17 }
stpDot1wRstpPortTxRstp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output statistics of RSTP packets"
--端口发送的RSTP报文个数
::= { stpDot1dStpPortEntry 18 }
stpDot1wRstpPortRxTcn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input statistics of TCN packets"
--端口接收的TCN报文个数
::= { stpDot1dStpPortEntry 19 }
stpDot1wRstpPortRxConfig OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input statistics of CONFIG packets"
--端口接收的CONFIG报文个数
::= { stpDot1dStpPortEntry 20 }
stpDot1wRstpPortRxRstp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input statistics of RSTP packets"
--端口接收的RSTP报文个数
::= { stpDot1dStpPortEntry 21 }
stpDot1wRstpPortClear OBJECT-TYPE
SYNTAX INTEGER{
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear port spanning-tree statistics"
--清除端口生成树统计信息
::= { stpDot1dStpPortEntry 22 }
stpDot1wRstpPortAdminP2p OBJECT-TYPE
SYNTAX INTEGER {
forceTrue(1),
forceFalse(2),
auto(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative point-to-point status of the LAN segment attached to this port"
--配置的端口的点对点链接状态
::= { stpDot1dStpPortEntry 23 }
stpDot1wRstpPortAdminEdge OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative value of the Edge Port parameter"
--配置的边界端口状态
::= { stpDot1dStpPortEntry 24 }
spanOnOff OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { enable }
Enable/Disable Spanning Tree for the bridge.
When 'disable(2)', all ports of the device are placed in the
forwarding mode, regardless of current Spanning Tree state.
When 'enable(1)', the normal STP state transitions take place."
::= { stpDot1dStp 17 }
stpDot1wRstpForceVersion OBJECT-TYPE
SYNTAX INTEGER {
ForceStp(0),
ForceRstp(2),
ForceMstp(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"which protocol mode the bridge chooses to execute ,RSTP or STP compatible"
--桥当前的协议模式,RSTP或者STP兼容模式
::= { stpDot1dStp 19 }
stpDot1dStpTrap OBJECT IDENTIFIER ::= { stpDot1dStp 18 }
----------------------------------------------------------------------------------
--STP TRAP MIB--
----------------------------------------------------------------------------------
stpDot1dStpPortBlocking NOTIFICATION-TYPE
OBJECTS { stpDot1dStpPortState }
STATUS current
DESCRIPTION
"Port status is turned from forwarding to blocking."
::= { stpDot1dStpTrap 1 }
stpDot1dStpPortException NOTIFICATION-TYPE
OBJECTS { stpDot1dStpPort }
STATUS current
DESCRIPTION
"Port packet flood to CPU rate is too big, port exception happen."
--如果端口冲击CPU的报文速率太大,则发出端口异常的trap
::= { stpDot1dStpTrap 2 }
stpDot1dStpPortRecover NOTIFICATION-TYPE
OBJECTS { stpDot1dStpPort }
STATUS current
DESCRIPTION
"Port recover time pass after port encounter port CAR exception, and Port packet flood to CPU rate is normal, recover port."
--端口被端口CAR关闭后,过了端口恢复时间,并且该端口下冲击CPU的速率正常,重新打开端口,并发送端口恢复trap
::= { stpDot1dStpTrap 3 }
stpDot1dStpPortRmtLoop NOTIFICATION-TYPE
OBJECTS { stpDot1dStpPort }
STATUS current
DESCRIPTION
"Port is blocked because of remote loop."
--端口因为远端环回而被block
::= { stpDot1dStpTrap 4 }
stpDot1dStpPortRmtLoopFree NOTIFICATION-TYPE
OBJECTS { stpDot1dStpPort }
STATUS current
DESCRIPTION
"Port is released from remote loop."
--端口远端环回解除
::= { stpDot1dStpTrap 5 }
stpDot1dStpNewRoot NOTIFICATION-TYPE
OBJECTS { stpDot1dStpDesignatedRoot }
STATUS current
DESCRIPTION
"Root bridge changed for the stp."
::= { stpDot1dStpTrap 6 }
stpDot1dStpPortForwarding NOTIFICATION-TYPE
OBJECTS { stpDot1dStpPortState }
STATUS current
DESCRIPTION
"Port status is turned from blocking to forwarding."
::= { stpDot1dStpTrap 7 }
-- -----------------------------------------------------------------------------
-- STP MIB - Conformance information
-- Not really necessary other than for strict interpretation of SMIv2
-- (and it doesn't hurt anything)
-- -----------------------------------------------------------------------------
stpMIBConformance OBJECT IDENTIFIER ::= { stpMib 2 }
stpMIBGroups OBJECT IDENTIFIER ::= { stpMIBConformance 1 }
stpMIBCompliances OBJECT IDENTIFIER ::= { stpMIBConformance 2 }
stpMIBBaseGroup OBJECT-GROUP
OBJECTS {
stpDot1dStpProtocolSpecification,
stpDot1dStpPriority,
stpDot1dStpTimeSinceTopologyChange,
stpDot1dStpTopChanges,
stpDot1dStpDesignatedRoot,
stpDot1dStpRootCost,
stpDot1dStpRootPort,
stpDot1dStpMaxAge,
stpDot1dStpHelloTime,
stpDot1dStpHoldTime,
stpDot1dStpForwardDelay,
stpDot1dStpBridgeMaxAge,
stpDot1dStpBridgeHelloTime,
stpDot1dStpBridgeForwardDelay,
stpPropStpEnable,
stpDot1dStpPort,
stpDot1dStpPortPriority,
stpDot1dStpPortState,
stpDot1dStpPortEnable,
stpDot1dStpPortPathCost,
stpDot1dStpPortDesignatedRoot,
stpDot1dStpPortDesignatedCost,
stpDot1dStpPortDesignatedBridge,
stpDot1dStpPortDesignatedPort,
stpDot1dStpPortForwardTransitions
}
STATUS current
DESCRIPTION
"STP module groups."
::= { stpMIBGroups 1 }
-- -----------------------------------------------------------------------------
-- STP MIB - Compliance information
-- -----------------------------------------------------------------------------
stpMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for STP module."
MODULE
MANDATORY-GROUPS {
stpMIBBaseGroup
}
::= { stpMIBCompliances 1 }
END
|