1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
|
--==================================================================
-- Copyright (C) 2015 by HUAWEI TECHNOLOGIES. All rights reserved.
--
-- Description: HUAWEI DATASYNC MIB
-- Reference:
-- Version: V2.02
-- History:
-- <author>, <date>, <contents>
-- fengchong 2009-03-17
-- ==================================================================
-- ==================================================================
--
-- Variables and types are imported
--
-- ==================================================================
HUAWEI-DATASYNC-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TimeTicks, Integer32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
hwDataSync MODULE-IDENTITY
LAST-UPDATED "201507161349Z"
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION
"Modified hwCfgChgTerminalID."
REVISION "201507161349Z"
DESCRIPTION
"Add hwCfgLastSaveFailNotify ."
REVISION "201409041710Z"
DESCRIPTION
"The MIB module for Data sync between host and netmanager."
REVISION "200903171027Z"
DESCRIPTION
"The initial revision of this MIB module ."
::= { hwDatacomm 191 }
DateAndTime ::= TEXTUAL-CONVENTION
DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d"
STATUS current
DESCRIPTION
"A date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes:
- the value of year is in network-byte order
- daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone
information (fields 8-10) is not present."
SYNTAX OCTET STRING (SIZE (8 | 11))
--
-- Node definitions
--
-- ==================================================================
--
-- ======================= definition begin =========================
--
-- ==================================================================
hwDataSyncScalarObjects OBJECT IDENTIFIER ::= { hwDataSync 1 }
hwDataSyncTableObjects OBJECT IDENTIFIER ::= { hwDataSync 2 }
hwDataSyncNotifications OBJECT IDENTIFIER ::= { hwDataSync 3 }
hwDataSyncConformance OBJECT IDENTIFIER ::= { hwDataSync 4 }
hwCurrentCfgChgSeqID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the ID of the current configuration change.
The value ranges from 0 to 65535. After the ID of the configuration change reaches
the maximum value, the value of the ID starts from 1 again.
After the device is restarted, the value of the ID becomes 0."
::= { hwDataSyncScalarObjects 1 }
hwCfgChgSeqIDReveralCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the cycle count of the index of configuration change table."
::= { hwDataSyncScalarObjects 2 }
hwCfgChgTableMaxItem OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the maximum number of entries in hwCfgChgTable. "
::= { hwDataSyncScalarObjects 3 }
hwCfgBaselineTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the time of system confiuration was baseline."
::= { hwDataSyncScalarObjects 4 }
hwDataSyncGroups OBJECT IDENTIFIER ::= { hwDataSyncConformance 1 }
hwDataSyncScalarObjectsGroup OBJECT-GROUP
OBJECTS { hwCurrentCfgChgSeqID, hwCfgChgSeqIDReveralCount, hwCfgChgTableMaxItem, hwCfgBaselineTime}
STATUS current
DESCRIPTION
"A collection of objects on DataSync ScalarObjects Information."
::= { hwDataSyncGroups 1 }
hwCfgChgNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS { hwCfgChgNotify}
STATUS current
DESCRIPTION
"A collection of objects on Configuration Change Information."
::= { hwDataSyncGroups 2 }
hwDataSyncNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS { hwCfgLastSaveFailNotify }
STATUS current
DESCRIPTION
"A collection of objects on synchronization Configuration Notify Information."
::= { hwDataSyncGroups 3 }
hwDataSyncCompliances OBJECT IDENTIFIER ::= { hwDataSyncConformance 2 }
hwDataSyncCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for
entities that support the huawei DataSync MIB."
MODULE -- this module
::= { hwDataSyncCompliances 1 }
hwCfgChgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCfgChgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to record configuration changes.
In this table, you can find the configuration change based on the specific index."
::= { hwDataSyncTableObjects 1 }
hwCfgChgEntry OBJECT-TYPE
SYNTAX HwCfgChgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of hwCfgChgTable."
INDEX { hwCfgChgSeqID }
::= { hwCfgChgTable 1 }
HwCfgChgEntry::=
SEQUENCE {
hwCfgChgSeqID
Integer32,
hwCfgChgTime
DateAndTime,
hwCfgChgTerminalType
INTEGER,
hwCfgChgTerminalID
Integer32,
hwCfgChgType
INTEGER,
hwCfgChgViewName
OCTET STRING,
hwCfgChgCmdID
Integer32,
hwCfgChgDetailInfo
OCTET STRING
}
hwCfgChgSeqID OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the configuration change ID.
When configuration is changed, the sequence id will plus 1."
::= { hwCfgChgEntry 1 }
hwCfgChgTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the configuration change time."
::= { hwCfgChgEntry 2 }
hwCfgChgTerminalType OBJECT-TYPE
SYNTAX INTEGER {snmp(1),telnet(2),netconf(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the type of the terminal."
::= { hwCfgChgEntry 3 }
hwCfgChgTerminalID OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the terminal ID."
::= { hwCfgChgEntry 4 }
hwCfgChgType OBJECT-TYPE
SYNTAX INTEGER {create(1),modify(2),delete(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the configuration change type."
::= { hwCfgChgEntry 5 }
hwCfgChgViewName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the name of the view in which the configuration change occurs.
For the command operation, the object is the name of the view in which the command is run.
For the SNMP operation, the object is the OID of the MIB table or the scalar object."
::= { hwCfgChgEntry 6 }
hwCfgChgCmdID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the ID of the configuration change command.
For the SNMP operation, the value is 0."
::= { hwCfgChgEntry 7 }
hwCfgChgDetailInfo OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates detailed configuration change information.
For the command operation, the object is the command line.
For the SNMP operation, the object is the index of the MIB table.
When there are multiple indexes, the format of index1.index2.index3 is adopted."
::= { hwCfgChgEntry 8 }
hwCollectTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCollectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to enable the NMS to send the collecting script to the device to trigger the collection,
and then monitor the collection status."
::= { hwDataSyncTableObjects 2 }
hwCollectEntry OBJECT-TYPE
SYNTAX HwCollectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of hwCollectTable."
INDEX { hwCollectIndex }
::= { hwCollectTable 1 }
HwCollectEntry ::=
SEQUENCE {
hwCollectIndex
Integer32,
hwCollectNetManageId
Integer32,
hwCollectOperation
INTEGER,
hwCollectInScriptFile
OCTET STRING,
hwCollectInResultFile
OCTET STRING,
hwCollectState
INTEGER,
hwCollectRowStatus
RowStatus
}
hwCollectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object identifies the collection index."
::= { hwCollectEntry 1 }
hwCollectNetManageId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the NMS ID."
::= { hwCollectEntry 2 }
hwCollectOperation OBJECT-TYPE
SYNTAX INTEGER {begin(1),stop(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the instruction for the collection operation.
Default value is stop."
::= { hwCollectEntry 3 }
hwCollectInScriptFile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the name of the script file. T
he length of the file name ranges from 1 character to 255 characters."
::= { hwCollectEntry 4 }
hwCollectInResultFile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the name of the result file.
The length of the file name ranges from 1 character to 255 characters."
::= { hwCollectEntry 5 }
hwCollectState OBJECT-TYPE
SYNTAX INTEGER {idle(1),collecting(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the collection status."
::= { hwCollectEntry 6 }
hwCollectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the row status."
::= { hwCollectEntry 7 }
hwCfgChgNotify NOTIFICATION-TYPE
OBJECTS {hwCurrentCfgChgSeqID, hwCfgChgSeqIDReveralCount, hwCfgChgTableMaxItem, hwCfgBaselineTime}
STATUS current
DESCRIPTION
"This trap is generated when a configuration change occurs
on the device within a specified period."
::= { hwDataSyncNotifications 1 }
hwCfgLastSaveFailNotify NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The last save operation failed, please check the configuration."
::= { hwDataSyncNotifications 2 }
END
--
-- HUAWEI-BULKSTAT-MIB.mib
--
|