summaryrefslogtreecommitdiff
path: root/MIBS/huawei/HUAWEI-ENERGYMNGT-MIB
blob: 8c8c9a45cf9044eee9cb264fa409cda82450edce (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
-- ============================================================================
-- Copyright (C) 2017 by  HUAWEI TECHNOLOGIES. All rights reserved.
-- Description: This mib is used for defining huawei's energy management MIB objects
-- Reference: None
-- Version:   V2.05
-- ============================================================================
HUAWEI-ENERGYMNGT-MIB DEFINITIONS ::= BEGIN

        IMPORTS

            IpAddress, Integer32, Counter64, OBJECT-TYPE, MODULE-IDENTITY,
            NOTIFICATION-TYPE
                FROM SNMPv2-SMI
            OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
                    FROM SNMPv2-CONF 
            InetAddressType, InetAddress            
                FROM INET-ADDRESS-MIB           
            DisplayString, DateAndTime, TruthValue, RowStatus
                FROM SNMPv2-TC
            huaweiUtility
                FROM HUAWEI-MIB ;

hwEnergyMngt MODULE-IDENTITY
       LAST-UPDATED "201706210000Z"
       ORGANIZATION "Huawei Technologies Co.,Ltd."
       CONTACT-INFO
"Huawei Industrial Base
  Bantian, Longgang
   Shenzhen 518129
   People's Republic of China
   Website: http://www.huawei.com
   Email: support@huawei.com
 "
            DESCRIPTION "huawei energy management MIB."
            REVISION    "201706210000Z"
            DESCRIPTION "V2.05. Modify the description of hwBoardName and hwBoardType ."

            REVISION    "201511110000Z"
            DESCRIPTION "V2.04. Add enum of hwEnergySavingMode:optimal."
            REVISION    "201505300000Z"
            DESCRIPTION "V2.03. Add enum of hwEnergySavingMode:optimal.
                                This is a draft version." 

            REVISION    "201401230000Z"
            DESCRIPTION "V2.02. Add hwEnergyDevId, hwEnergyDevChangeToSleep.
                                This is a draft version."    
        

            REVISION    "201107010000Z"
            DESCRIPTION "V0.114. Add hwPoEType, hwPSEPower.
                                 Modify FTPC table.
                                 This is a draft version."           

            REVISION    "201103141530Z"
            DESCRIPTION "V0.113, add hwEnergyFtpcIpv4TransMode and hwEnergyFtpcTransMode.
                                This is a draft version."           
            
            REVISION    "201103140000Z"
            DESCRIPTION "V0.112, modify hwEnergyFtpcTransFileIpv4Table and hwEnergyFtpcTransFileTable.
                                This is a draft version."           
            
            REVISION    "201103100000Z"
            DESCRIPTION "V0.111, add hwEnergyFtpcObjects, 
                                including hwEnergyFtpcTransFileIpv4Table and hwEnergyFtpcTransFileTable.
                                This is a draft version."

            REVISION    "201102100000Z"
            DESCRIPTION "V0.11, add hwEnergySavingDescReqMode."

            REVISION    "201008060000Z"
            DESCRIPTION "V0.10, modify hwBoardIndex."

            REVISION    "201008050000Z"
            DESCRIPTION "V0.09, modify hwBoardType."

            REVISION    "201008030000Z"
            DESCRIPTION "V0.08, modify watt to milliwatt.
                         Modify enumeration of hwEnergySavingMode.
                         Add boardType and boardDescription."

        REVISION    "201007120000Z"
            DESCRIPTION "V0.08, modify hwPowerStatPeriod."

            REVISION    "201007070000Z"
            DESCRIPTION "V0.06, modify hwPowerStatPeriod."

            REVISION    "201006290000Z"
            DESCRIPTION "V0.05, modify hwEnergySavingMethodEnable value list.
                         Delete hwEnergySavingParameterTable first index 'hwEnergySavingMethodIndex'"

            REVISION    "201006230000Z"
            DESCRIPTION "V0.05, modify hwEnergySavingCapabilityMngtEntry, modify hwEnergySavingMethodTable"

            REVISION    "201006180000Z"
            DESCRIPTION "V0.04, modify hwEnergySavingCapabilityMngtEntry"

            REVISION    "201006170000Z"
            DESCRIPTION "V0.03, modify description for all MIB table"

            REVISION    "201006080000Z"
            DESCRIPTION "V0.02, add hwEnergySavingMethodEntry, add hwEnergySavingCapabilityMngt"

            REVISION    "201005240000Z"
            DESCRIPTION "V0.01 mib initial"

        ::= { huaweiUtility 157 }


    
--
-- Node definitions
--
    
        -- 1.1
        hwSysPowerMgnt OBJECT IDENTIFIER ::= { hwEnergyMngt 1 }

        
        -- 1.1.1
        hwPowerConsumption OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "NE total power consumption, counted from equipment first used.
                 Joule(Watt * second).
                 Note: If the device is a power supplier(PSE), the power consumption includes the outputs."
            ::= { hwSysPowerMgnt 1 }

        
        -- 1.1.2
        hwPowerStatPeriod OBJECT-TYPE
            SYNTAX INTEGER
                          {
                fifteenMinutes(1),
                thirtyMinutes(2),
                oneHour(3),
                oneDay(4),
                oneWeek(5),
                oneMonth(6)
               }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "NE power statistics period: 
                fifteenMinutes(1):  The power statistics generated every 15 minutes.
                thirtyMinutes(2):   The power statistics generated every 30 minutes.
                oneHour(3):         The power statistics generated every hour. 
                oneDay(4):          The power statistics generated every day.
                oneWeek(5):         The power statistics generated every week.
                oneMonth(6):        The power statistics generated every month.
                The defaut statistics intervalue is one hour."
            DEFVAL {oneHour}
            ::= { hwSysPowerMgnt 2 }

        
        -- 1.1.3
        hwAveragePower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "NE average power consumtion during a period: milliwatt"
            ::= { hwSysPowerMgnt 3 }

        
        -- 1.1.4
        hwRatedPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "NE rated power: milliwatt"
            ::= { hwSysPowerMgnt 4 }

        
        -- 1.1.5
        hwThresholdOfPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "NE threshold power: milliwatt"
            ::= { hwSysPowerMgnt 5 }

        
        -- 1.1.6
        hwCurrentPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "NE current power: milliwatt"
            ::= { hwSysPowerMgnt 6 }


        -- 1.1.7
        hwPoEType OBJECT-TYPE
            SYNTAX INTEGER
            {
                pse(1),
                pd(2),
                noPoe(255)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "powered type:
                PSE(1): power supplier.
                PD(2): powered deivce.
                noPoe(255): not PSE or PD"
            ::= { hwSysPowerMgnt 7 }


        -- 1.1.8
        hwPSEPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The output power(milliwatt) by a PSE. For a non-PSE device, the value is zero."
            ::= { hwSysPowerMgnt 8 }


        -- 1.2
        hwBoardPowerMngt OBJECT IDENTIFIER ::= { hwEnergyMngt 2 }

        
        -- 1.2.1
        hwBoardPowerMngtTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwBoardPowerMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table describes current power and rated power of boards. The index is hwBoardIndex."
            ::= { hwBoardPowerMngt 1 }

        
        -- 1.2.1.1
        hwBoardPowerMngtEntry OBJECT-TYPE
            SYNTAX HwBoardPowerMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of hwBoardPowerMngtTable."
            INDEX { hwBoardIndex }
            ::= { hwBoardPowerMngtTable 1 }

        
        HwBoardPowerMngtEntry ::=
            SEQUENCE { 
                hwBoardIndex
                    Integer32,
                hwBoardType
                    DisplayString,
                hwBoardName
                    DisplayString,
                hwBoardCurrentPower
                    Integer32,
                hwBoardRatedPower
                    Integer32,
                hwBoardThresholdOfPower
                    Integer32
                    }

        -- 1.2.1.1.1
        hwBoardIndex OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Index: reserved/shelf/frame/slot.
                The index is format by 4 bytes(8bit for 1 byte): reservedByte(0xFF), shelfID, frameID, slotID.
                e.g. shlef=1, frame=2, slot=17, the index is 0xFF010211(66065).
                If no shelfID or frameID, the corresponding byte is set to be 0xFF.
                e.g. no shlefID, no frameID, slot=17, the index is 0xFFFFFF11(4294967057).
                "
            ::= { hwBoardPowerMngtEntry 1 }


        -- 1.2.1.1.2
        hwBoardType OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "hwBoardType describes main type of board.
                "
            ::= { hwBoardPowerMngtEntry 2 }


        -- 1.2.1.1.3
        hwBoardName OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "hwBoardName describes full name of board.
                "
            ::= { hwBoardPowerMngtEntry 3 }


        -- 1.2.1.1.4
        hwBoardCurrentPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "current power of board(slot): milliwatt"
            ::= { hwBoardPowerMngtEntry 4 }

        
        -- 1.2.1.1.5
        hwBoardRatedPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "rated power of board(slot): milliwatt"
            ::= { hwBoardPowerMngtEntry 5 }


        -- 1.2.1.1.6
        hwBoardThresholdOfPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Threshold power of board(slot): milliwatt"
            ::= { hwBoardPowerMngtEntry 6 }



        
        -- 1.3
        hwEnergySavingMngt OBJECT IDENTIFIER ::= { hwEnergyMngt 3 }

        
        -- 1.3.1
        hwEnergySavingMode OBJECT-TYPE
            SYNTAX INTEGER
                {
                userDefined(1),
                standard(2),
                basic(3),
                deep(4),
                optimal(5)
                }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Power saving mode:
                 UserDefined(1): UserDined energy-saving mode, user can define energy-saving strategy.
                 Standard(2): standard energy-saving mode
                 Basic(3): basic energy-saving mode, many basic energy-saving strategy included.
                 Deep(4): Deep energy-saving mode, many complex energy-saving strategy included, which may effect service.
                 Optimal(5): Optimal energy-saving mode, many complex energy-saving strategy included, which may effect service.
                "
            ::= { hwEnergySavingMngt 1 }

        
        -- 1.3.2
        hwEnergySavingMethodTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEnergySavingMethodEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "hwEnergySavingMethodTable defines energy-saving Method for all mode.
                User can set a method with its parameter.
                The index of this table is hwEnergySavingMethodIndex.
                "
            ::= { hwEnergySavingMngt 2 }

        
        -- 1.3.2.1
        hwEnergySavingMethodEntry OBJECT-TYPE
            SYNTAX HwEnergySavingMethodEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Entry of energy-saveing method table."
            INDEX { hwEnergySavingMethodIndex }
            ::= { hwEnergySavingMethodTable 1 }

        
        HwEnergySavingMethodEntry ::=
            SEQUENCE { 
                hwEnergySavingMethodIndex
                    Integer32,
                hwEnergySavingMethodEnable
                    INTEGER
                }

        -- 1.3.2.1.1
        hwEnergySavingMethodIndex OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The index of method in use.
                "
            ::= { hwEnergySavingMethodEntry 1 }

        -- 1.3.2.1.2
        hwEnergySavingMethodEnable OBJECT-TYPE
            SYNTAX INTEGER
            {
                enable(1),
                disable(2)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "hwEnergySaveingMethodEnable describes the status of energy-saving method: enableed or disabled.
                "
            ::= { hwEnergySavingMethodEntry 2 }


        
        -- 1.3.3
        hwEnergySavingParameterTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEnergySavingParameterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "hwEnergySavingParameterTable defines parameters for all energy-saving methods.
                User can set parameter for a method.
                The index of this table: hwEnergySavingMethodIndex, hwEnergySavingParameterIndex."
            ::= { hwEnergySavingMngt 3 }

        
        -- 1.3.3.1
        hwEnergySavingParameterEntry OBJECT-TYPE
            SYNTAX HwEnergySavingParameterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Entry of energy-saveing parameter table."
            INDEX { hwEnergySavingMethodIndex, hwEnergySavingParameterIndex }
            ::= { hwEnergySavingParameterTable 1 }

        
        HwEnergySavingParameterEntry ::=
            SEQUENCE { 
                hwEnergySavingParameterIndex
                    Integer32,
                hwEnergySavingParameterValue
                    DisplayString (SIZE (0..64))
             }

        -- 1.3.3.1.1
        hwEnergySavingParameterIndex OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The second index of hwEnergySavingParameterTable.
                An energy-saving method might have more than one parameter.
                This index is used to identify the parameter for a method."
            ::= { hwEnergySavingParameterEntry 1 }

        -- 1.3.3.1.2
        hwEnergySavingParameterValue OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The value of an energy-saveing method's parameter.
                 The parameter is a format string. 
                 When NMS sets integer 12 as a parameter for a energy-saving method, the value is a string '12'.
                "
            ::= { hwEnergySavingParameterEntry 2 }

            

        -- 1.3.4
        hwEnergySavingCapabilityMngtTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEnergySavingCapabilityMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table describes the energy-saving capability, including energy-saving methods and parameters.
                The index is hwEnergySavingCapabilityDescIndex.
                "
            ::= { hwEnergySavingMngt 4 }

        
        -- 1.3.4.1
        hwEnergySavingCapabilityMngtEntry OBJECT-TYPE
            SYNTAX HwEnergySavingCapabilityMngtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of hwBoardPowerMngtTable."
            INDEX { hwEnergySavingCapabilityDescIndex }
            ::= { hwEnergySavingCapabilityMngtTable 1 }

        
        HwEnergySavingCapabilityMngtEntry ::=
            SEQUENCE { 
                hwEnergySavingCapabilityDescIndex
                    Integer32,
                hwEnergySavingCapabilityDescLanguage
                    DisplayString (SIZE (0..64)),
                hwEnergySavingCapabilityDesc
                    OCTET STRING
                    }
        
        -- 1.3.4.1.1
        hwEnergySavingCapabilityDescIndex OBJECT-TYPE
            SYNTAX Integer32 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The index of hwEnergySavingCapabilityMngtTable.
                "
            ::= { hwEnergySavingCapabilityMngtEntry 1 }

        -- 1.3.4.1.2
        hwEnergySavingCapabilityDescLanguage OBJECT-TYPE
            SYNTAX DisplayString 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The language of EnergySavingCapabilityDescription file.
                'en-gb'(English-GreatBraitain)
                'zh-cn'(Chinese)
                "
            ::= { hwEnergySavingCapabilityMngtEntry 2 }

        -- 1.3.4.1.3
        hwEnergySavingCapabilityDesc OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..10240)) 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "User can get the description string from hwEnergySavingCapabilityDesc.
                An XML file which is compressed by ZIP to less than 10240 bytes,
                describes the energy-saving capability, including all energy-saving methods and parameters.
                "
            ::= { hwEnergySavingCapabilityMngtEntry 3 }

        
        -- 1.3.5
        hwEnergySavingDescReqMode OBJECT-TYPE
            SYNTAX INTEGER
                {
                snmp(1),
                ftp(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The mode describes how to get energy saving capability description file :
                 snmp(1): Get the file using hwEnergySavingCapabilityDesc.
                 ftp(2): Get the file using FTP, which described by hwEnergyFtpclientReqTable.
                "
            ::= { hwEnergySavingMngt 5 }



    -- 1.4
        hwEnergyFtpcObjects OBJECT IDENTIFIER ::= { hwEnergyMngt 4 }

-- == Ftpc Table ==
        hwEnergyFtpcTransFileTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEnergyFtpcTransFileEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table is used to configure transfer file feature related parameters."
            ::= { hwEnergyFtpcObjects 1 }

        
        hwEnergyFtpcTransFileEntry OBJECT-TYPE
            SYNTAX HwEnergyFtpcTransFileEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Name identifying Transfer configuration"
            INDEX { hwEnergyFtpcSetName }
            ::= { hwEnergyFtpcTransFileTable 1 }

        
        HwEnergyFtpcTransFileEntry ::=
            SEQUENCE { 
                hwEnergyFtpcSetName
                    OCTET STRING,
                hwEnergyFtpcSrcAddrType
                    InetAddressType,
                hwEnergyFtpcSrcAddr
                    InetAddress,
                hwEnergyFtpcVpnName
                    OCTET STRING,
                hwEnergyFtpcHostAddrType
                    InetAddressType,
                hwEnergyFtpcHostAddr
                    InetAddress,
                hwEnergyFtpcServerPort
                    Integer32,
                hwEnergyFtpcUserName
                    OCTET STRING,
                hwEnergyFtpcPassword
                    OCTET STRING,
                hwEnergyFtpcDirectory
                    OCTET STRING,
                hwEnergyFtpcSrcIfName
                    OCTET STRING,
                hwEnergyFtpcTransCfgRowStatus
                    RowStatus,
                    hwEnergyFtpcAction
                    INTEGER,
                hwEnergyFtpcTransMode
                        INTEGER,
                hwEnergyFtpOperStatus
                        INTEGER
             }

        hwEnergyFtpcSetName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..31))
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Name identifying FTPC Transfer configuration"
            ::= { hwEnergyFtpcTransFileEntry 1 }

        
        hwEnergyFtpcSrcAddrType OBJECT-TYPE
            SYNTAX InetAddressType
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Source IP address Type:
                ipv4(1)
                ipv6(2)"
            ::= { hwEnergyFtpcTransFileEntry 2 }

        
        hwEnergyFtpcSrcAddr OBJECT-TYPE
            SYNTAX InetAddress
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Source IP address"
            ::= { hwEnergyFtpcTransFileEntry 3 }

        
        hwEnergyFtpcVpnName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..31))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "VPN name used for the corresponding connection"
            ::= { hwEnergyFtpcTransFileEntry 4 }

        
        hwEnergyFtpcHostAddrType OBJECT-TYPE
            SYNTAX InetAddressType
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Server address type:
                ipv4(1)
                ipv6(2)"
            ::= { hwEnergyFtpcTransFileEntry 5 }

        
        hwEnergyFtpcHostAddr OBJECT-TYPE
            SYNTAX InetAddress
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Server IP address"
            ::= { hwEnergyFtpcTransFileEntry 6 }

        
        hwEnergyFtpcServerPort OBJECT-TYPE
            SYNTAX Integer32 (21 | 1025..55535)
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Server port used for connection"
            ::= { hwEnergyFtpcTransFileEntry 7 }

        
        hwEnergyFtpcUserName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..85))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "User Name used for user validation"
            ::= { hwEnergyFtpcTransFileEntry 8 }

        
        hwEnergyFtpcPassword OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..25))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Password used for user validation. Password Length while setting should not be more than
                16 characters, while querying password will be cipher text"
            ::= { hwEnergyFtpcTransFileEntry 9 }

        
        hwEnergyFtpcDirectory OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..256))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Local working directory"
            ::= { hwEnergyFtpcTransFileEntry 10 }

        
        hwEnergyFtpcSrcIfName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..48))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Interface Name"
            ::= { hwEnergyFtpcTransFileEntry 11 }

        
        hwEnergyFtpcTransCfgRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "The object specifies the status of this table
                entry. When the status is createAndGo, it
                allows to create  and when value is destroy
                it allows to delete the record in the table"
            ::= { hwEnergyFtpcTransFileEntry 12 }

    
        hwEnergyFtpcAction OBJECT-TYPE
            SYNTAX INTEGER {
                                    get(1),
                                    put(2)
                                   }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The type of request.
                              get(1): To request a file from the FTP server.
                              put(2): To send a file to the FTP server."
            ::= { hwEnergyFtpcTransFileEntry 13 }


        hwEnergyFtpcTransMode OBJECT-TYPE
            SYNTAX INTEGER {
                                    ftp(1),
                                    sftp(2),
                                    tftp(3)
                                   }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The file transfer protocol. Default: FTP."
            ::= { hwEnergyFtpcTransFileEntry 14 }


        hwEnergyFtpOperStatus OBJECT-TYPE
            SYNTAX INTEGER {
                                    opInProgress(1),
                                    opSuccess(2),
                                    opInvalid(3),
                                    opInvalidProtocol(4),
                                    opInvalidSourceName(5),
                                    opInvalidDestName(6),
                                    opInvalidServerAddress(7),
                                    opDeviceBusy(8),
                                    opDeviceError(9),
                                    opFileOpenError(10),
                                    opFileTransferError(11),
                                    opFileChecksumError(12),
                                    opAuthFail(13),
                                    opUnknownFailure(14),
                                    opAbort(15),
                                    opInvalidSourceAddress(16),
                                    opInvalidSourceInterface(17)
                                   }            
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The OperStatus:
                 opInProgress(1): the operation is in process.
                                 opSuccess(2): the operation has been completed successfully.
                                 opInvalid(3): the command is invalid or command-protocol-device combination is unsupported by the system.
                                 opInvalidProtocol(4): invalid protocol is specified
                                 opInvalidSourceName(5) :invalid source file name is specified.    
                                 opInvalidDestName(6): invalid target name is specified.    
                                 opInvalidServerAddress(7): invalid server address is specified
                                 opDeviceBusy(8): the device is in use and locked by another process
                                 opDeviceError(9): device read, write or erase error
                                 opFileOpenError(10) :invalid file name; file not found in partition
                                 opFileTransferError(11) :file transfer was unsuccessfull
                                 opFileChecksumError(12) :file checksum in Flash is invalid
                                 opAuthFail(13) :authentication failure
                                 opUnknownFailure(14) :failure which is unknown
                                 opAbort(15) : transfer operation has been aborted
                                 opInvalidSourceAddress(16): invalid source IP is specified.
                                 opInvalidSourceInterface(17): invalid source interface is specified.
"
            ::= { hwEnergyFtpcTransFileEntry 15 }

                                  hwEnergyTrapObjects OBJECT IDENTIFIER ::= { hwEnergyMngt 10 }
    
                                  hwEnergyDevId OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS accessible-for-notify
            STATUS current
            DESCRIPTION
                "This object identifies the device ID."
            ::= { hwEnergyTrapObjects 1 }       
    
    
                                  hwEnergyNotification OBJECT IDENTIFIER ::= { hwEnergyMngt 11 }
    
                                  hwEnergyDevChangeToSleep NOTIFICATION-TYPE
            OBJECTS { hwEnergyDevId }
            STATUS current
            DESCRIPTION 
                "This notification indicates device entering in the sleeping status."
            ::= { hwEnergyNotification 1 }     



        
        hwEnergyConformance OBJECT IDENTIFIER ::= { hwEnergyMngt 6 }

        
        hwEnergyCompliances OBJECT IDENTIFIER ::= { hwEnergyConformance 1 }

        
        hwEnergyCompliance MODULE-COMPLIANCE
            STATUS current
            DESCRIPTION 
                "Description."
            MODULE -- this module
                MANDATORY-GROUPS { hwEnergyFtpcGroup }
            ::= { hwEnergyCompliances 1 }

        
        hwEnergyGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 2 }

        
        hwEnergyFtpcGroup OBJECT-GROUP
            OBJECTS { hwEnergyFtpcSrcAddrType, hwEnergyFtpcSrcAddr, hwEnergyFtpcVpnName, hwEnergyFtpcHostAddrType, hwEnergyFtpcHostAddr, 
                hwEnergyFtpcServerPort, hwEnergyFtpcUserName, hwEnergyFtpcPassword, hwEnergyFtpcDirectory, hwEnergyFtpcSrcIfName, 
                hwEnergyFtpcTransCfgRowStatus }
            STATUS current
            DESCRIPTION 
                "Description."
            ::= { hwEnergyGroups 1 }

--      hwSysPowerMgntGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 3 }
        hwSysPowerMgntGroup OBJECT-GROUP
            OBJECTS { hwThresholdOfPower,hwPowerConsumption,hwPowerStatPeriod,hwAveragePower,hwRatedPower,hwCurrentPower,hwPSEPower,hwPoEType }
            STATUS current
            DESCRIPTION 
                "Description."
            ::= { hwEnergyGroups 2 }

--      hwEnergySavingMngtGroups OBJECT IDENTIFIER ::= { hwEnergyConformance 4 }
        
        hwEnergySavingMngtGroup OBJECT-GROUP
            OBJECTS { hwEnergySavingMode,hwEnergySavingMethodIndex,hwEnergySavingParameterIndex,hwEnergySavingCapabilityDescIndex,hwEnergySavingDescReqMode }
            STATUS current
            DESCRIPTION 
                "Description."
            ::= { hwEnergyGroups 3 }

                                    hwEnergyNotificationGroup NOTIFICATION-GROUP
                                                   NOTIFICATIONS { hwEnergyDevChangeToSleep }
                                                   STATUS        current
                                                   DESCRIPTION
                                                   "Description."
                                                   ::= { hwEnergyGroups 4 }

    END

--
-- HUAWEI-ENERGYMNGT-MIB
--