summaryrefslogtreecommitdiff
path: root/MIBS/imco/IMCO-LS110-MIB
blob: 0961e2ff824dae17af0c832e5ce358d51c492c4e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
IMCO-LS110-MIB DEFINITIONS ::= BEGIN

IMPORTS
     MODULE-IDENTITY, OBJECT-TYPE,
     Counter32, Integer32, Gauge32,
     TimeTicks, IpAddress,
     enterprises
    FROM SNMPv2-SMI
    TRAP-TYPE FROM RFC-1215;
 

mib-AN-Dcz-SDS MODULE-IDENTITY
    LAST-UPDATED "201702090000Z"
    ORGANIZATION "ViaNet.sk"
    CONTACT-INFO
            "   Ivan Mochnac
                ViaNet
                -
                -
                SK EUROPE

                -
                vianet@vianet.sk"
    DESCRIPTION
            "The MIB module to describe PSMSmicro version of SDS."


    REVISION      "201702090000Z"
    DESCRIPTION
            "PSMSmicro, by ViaNet.sk."
    ::= { enterprises 33283 }


--
-- MIB file definition for device: PSMSmicro
--

sdsxpublic OBJECT IDENTIFIER ::= { mib-AN-Dcz-SDS 1 }

sdsBIGandSTSW   OBJECT IDENTIFIER ::= { sdsxpublic 30 }

-- ****************************************************************************

sdsOptoInput OBJECT IDENTIFIER ::= { sdsBIGandSTSW 2 }

opto1 OBJECT-TYPE
    SYNTAX  INTEGER {
                activeSignalPresent(0),
                noSignal(32768)
            }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Current OPTO1 binary input status."
    ::= { sdsOptoInput 1 }

opto2 OBJECT-TYPE
    SYNTAX  INTEGER {
                activeSignalPresent(0),
                noSignal(1)
            }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Current OPTO2 binary input status."
    ::= { sdsOptoInput 2 }

opto3 OBJECT-TYPE
    SYNTAX  INTEGER {
                activeSignalPresent(0),
                noSignal(2)
            }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Current Mains (OPTO3) binary input status."
    ::= { sdsOptoInput 3 }

-- ****************************************************************************

sdsOutputRelays OBJECT IDENTIFIER ::= { sdsBIGandSTSW 3 }

sdsOutputRelay1 OBJECT IDENTIFIER ::= { sdsOutputRelays 1 }

sdsRE1state OBJECT-TYPE
    SYNTAX  INTEGER {
                off(0),
                activated(255)
            }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "Current RELAY 1 output status."
    ::= { sdsOutputRelay1 1 }

sdsOutputRelay2 OBJECT IDENTIFIER ::= { sdsOutputRelays 2 }

sdsRE2state OBJECT-TYPE
    SYNTAX  INTEGER {
                off(0),
                activated(255)
            }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "Current RELAY 2 output status."
    ::= { sdsOutputRelay2 1 }

sdsOutputRelay3 OBJECT IDENTIFIER ::= { sdsOutputRelays 3 }

sdsRE3state OBJECT-TYPE
    SYNTAX  INTEGER {
                off(0),
                activated(255)
            }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
            "Current RELAY 3 output status."
    ::= { sdsOutputRelay3 1 }    

-- ****************************************************************************

sdsADCinputs OBJECT IDENTIFIER ::= { sdsBIGandSTSW 5 }

sdsADCitem0 OBJECT IDENTIFIER ::= { sdsADCinputs 1 }

sdsTempSensValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Temperature Sensor (C) multiplied by 100."
    ::= { sdsADCitem0 3 }

sdsTempSensName OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "User name for the analog temperature sensor."
    ::= { sdsADCitem0 4 }
 
-- ****************************************************************************

sdsADCvalues OBJECT IDENTIFIER ::= { sdsBIGandSTSW 7 }

sdsMaximumLoad OBJECT-TYPE
    SYNTAX    Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Maximum Load (W) multiplied by 10."
    ::= { sdsADCvalues 2 }

sdsAlarmText OBJECT-TYPE
    SYNTAX    OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "SDS Alarm Text."
    ::= { sdsADCvalues 3 }

sdsOutputVoltage1 OBJECT-TYPE
    SYNTAX    Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Output voltage U1 (V) multiplied by 100."
    ::= { sdsADCvalues 4 }

sdsOutputVoltage2 OBJECT-TYPE
    SYNTAX    Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Output voltage U2 (V) multiplied by 100."
    ::= { sdsADCvalues 5 }

sdsOutputCurrent OBJECT-TYPE
    SYNTAX    Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Output current I (A) multiplied by 10."
    ::= { sdsADCvalues 6 }

sdsBatteryCapacity OBJECT-TYPE
    SYNTAX    Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Battery Capacity (%) multiplied by 10."
    ::= { sdsADCvalues 7 }
    
sdsLoad OBJECT-TYPE
    SYNTAX    Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Load (%) multiplied by 10."
    ::= { sdsADCvalues 8 }
    
sdsCapTestTime OBJECT-TYPE
    SYNTAX    Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Time (min) of last Capacity Test."
    ::= { sdsADCvalues 9 }    

-- ****************************************************************************

sdsGeneralInfoEntry OBJECT IDENTIFIER ::= { sdsBIGandSTSW 8 }

sdsManufacturer OBJECT-TYPE
    SYNTAX    OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Manufacturer of the device."
    ::= { sdsGeneralInfoEntry 80 }

sdsModel OBJECT-TYPE
    SYNTAX    OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Model (type) of the device."
    ::= { sdsGeneralInfoEntry 81 }

sdsName OBJECT-TYPE
    SYNTAX    OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Name/Location of the device."
    ::= { sdsGeneralInfoEntry 82 }

sdsSerialNumber OBJECT-TYPE
    SYNTAX    OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Serial number of the device."
    ::= { sdsGeneralInfoEntry 83 }

sdsSoftware OBJECT-TYPE
    SYNTAX    OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Software version of the device."
    ::= { sdsGeneralInfoEntry 84 }

-- ****************************************************************************

-- ****************************************************************************
-- TRAP-SDS-MICRO-MIB DEFINITIONS 
-- ****************************************************************************

opto1-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { opto1 }
	DESCRIPTION "TRAP: optical input 1 status."
	::= 100

opto2-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { opto2 }
	DESCRIPTION "TRAP: optical input 2 status."
	::= 101

opto3-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { opto3 }
	DESCRIPTION "TRAP: optical input 3 status."
	::= 102

-- next

sdsRE1state-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsRE1state }
	DESCRIPTION "TRAP: Current RELAY 1 output status."
    ::= 150

sdsRE2state-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsRE2state }
	DESCRIPTION "TRAP: Current RELAY 2 output status."
    ::= 153

-- next

sdsTempSensValue-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsTempSensValue }
	DESCRIPTION "TRAP: Temperature Sensor (C) multiplied by 100."
    ::= 222

sdsTempSensName-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsTempSensName }
	DESCRIPTION "TRAP: User name for analog temperature sensor."
    ::= 223

-- next

sdsMaximumLoad-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsMaximumLoad }
        DESCRIPTION "TRAP: SDS Maximum Load-trap."
    ::= 401

sdsAlarmText-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsAlarmText }
        DESCRIPTION "TRAP: SDS Alarm Text."
    ::= 402

sdsOutputVoltage1-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsOutputVoltage1 }
        DESCRIPTION "TRAP: SDS Output Voltage1-trap."
    ::= 403

sdsOutputVoltage2-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsOutputVoltage2 }
        DESCRIPTION "TRAP: SDS Outpur Voltage2-trap."
    ::= 404

sdsOutputCurrent-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsOutputCurrent }
        DESCRIPTION "TRAP: SDS Output current-trap."
    ::= 405

sdsBatteryCapacity-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsBatteryCapacity }
        DESCRIPTION "TRAP: SDS Battery Capacity-trap."
    ::= 406
    
sdsLoad-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsLoad }
        DESCRIPTION "TRAP: SDS Load-trap."
    ::= 407

sdsCapTestTime-trap TRAP-TYPE
	-- STATUS current
	ENTERPRISE mib-AN-Dcz-SDS
	VARIABLES { sdsCapTestTime }
        DESCRIPTION "TRAP: SDS CapTestTime-trap."
    ::= 408

-- end

END