1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
|
--
-- Juniper Enterprise Specific MIB: Ping MIB
--
-- Copyright (c) 2001-2012, Juniper Networks, Inc.
-- All rights reserved.
--
-- The contents of this document are subject to change without notice.
--
JUNIPER-PING-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, Unsigned32,
NOTIFICATION-TYPE
FROM SNMPv2-SMI -- RFC2578
InterfaceIndexOrZero
FROM IF-MIB -- RFC2863
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC2571
DisplayString, DateAndTime, TruthValue
FROM SNMPv2-TC
pingResultsEntry, pingProbeHistoryEntry, pingCtlTargetAddressType,
pingCtlTargetAddress, pingResultsOperStatus, pingResultsIpTargetAddressType,
pingResultsIpTargetAddress, pingResultsMinRtt, pingResultsMaxRtt,
pingResultsAverageRtt, pingResultsProbeResponses, pingResultsSentProbes,
pingResultsRttSumOfSquares, pingResultsLastGoodProbe,
OperationResponseStatus
FROM DISMAN-PING-MIB
InetPortNumber
FROM INET-ADDRESS-MIB
jnxMibs, jnxPingNotifications
FROM JUNIPER-SMI;
jnxPingMIB MODULE-IDENTITY
LAST-UPDATED "200911180000Z" -- November 18 00:00:00 2009 UTC
ORGANIZATION "Juniper Networks, Inc."
CONTACT-INFO
" Juniper Technical Assistance Center
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, CA 94089
E-mail: support@juniper.net"
DESCRIPTION
"This is Juniper Networks' implementation of enterprise specific
portions of pingMib. Any data stored in this MIB has directly
related entries in mib-2, pingMIB."
-- revision history
REVISION "201109200000Z" -- September 20 00:00:00 2011 UTC
DESCRIPTION
"Updated the jnxPingCtlTargetPort description."
REVISION "200911180000Z" -- November 18 00:00:00 2009 UTC
DESCRIPTION
"Added jnxPingCtlEXseriesHWTimeStamp to jnxPingCtlTable."
REVISION "200904200000Z" -- April 20 00:00:00 2009 UTC
DESCRIPTION
"Added jnxPingCtlTargetPort to jnxPingCtlTable."
REVISION "200505010000Z" -- May 1 00:00:00 2005 UTC
DESCRIPTION
"Added jnxPingCtlTargetPort to jnxPingCtlTable."
REVISION "200404150000Z" -- April 15 00:00:00 2004 UTC
DESCRIPTION
"Added traps plus additional results & history data."
::= { jnxMibs 7 }
jnxPingObjects OBJECT IDENTIFIER ::= { jnxPingMIB 1 }
-- The registration node for ping implementation types
jnxPingImplementationTypeDomains OBJECT IDENTIFIER ::= { jnxPingMIB 2 }
jnxPingIcmpTimeStamp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using the Internet
Control Message Protocol (ICMP) 'TimeStamp' facility.
This probe-type provides egress and ingress delay measurements."
::= { jnxPingImplementationTypeDomains 1 }
jnxPingHttpGet OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using an HTTP GET query to
calculate a round trip time."
::= { jnxPingImplementationTypeDomains 2 }
jnxPingHttpGetMetadata OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using an HTTP GET Metadata query to
calculate a round trip time."
::= { jnxPingImplementationTypeDomains 3 }
jnxPingDnsQuery OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using a DNS query to
calculate a round trip time."
::= { jnxPingImplementationTypeDomains 4 }
jnxPingNtpQuery OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using an NTP query to
calculate a round trip time."
::= { jnxPingImplementationTypeDomains 5 }
jnxPingUdpTimestamp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using a UDP timestamp query to
calculate a round trip time. This probe-type provides egress and
ingress delay measurements"
::= { jnxPingImplementationTypeDomains 6 }
--
-- pingCtlTable extensions
--
jnxPingCtlTable OBJECT-TYPE
SYNTAX SEQUENCE OF JnxPingCtlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the jnxPing Control Table for providing enterprise specific
options to the corresponding pingCtlTable entry."
::= { jnxPingObjects 2 }
jnxPingCtlEntry OBJECT-TYPE
SYNTAX JnxPingCtlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the jnxPingCtlTable. This essentially
augments the pingCtlTable with additional objects."
INDEX {
jnxPingCtlOwnerIndex,
jnxPingCtlTestName
}
::= { jnxPingCtlTable 1 }
JnxPingCtlEntry ::=
SEQUENCE {
jnxPingCtlOwnerIndex SnmpAdminString,
jnxPingCtlTestName SnmpAdminString,
jnxPingCtlIfName DisplayString,
jnxPingCtlRoutingIfIndex InterfaceIndexOrZero,
jnxPingCtlRoutingIfName DisplayString,
jnxPingCtlRoutingInstanceName DisplayString,
jnxPingCtlRttThreshold Unsigned32,
jnxPingCtlRttStdDevThreshold Unsigned32,
jnxPingCtlRttJitterThreshold Unsigned32,
jnxPingCtlEgressTimeThreshold Unsigned32,
jnxPingCtlEgressStdDevThreshold Unsigned32,
jnxPingCtlEgressJitterThreshold Unsigned32,
jnxPingCtlIngressTimeThreshold Unsigned32,
jnxPingCtlIngressStddevThreshold Unsigned32,
jnxPingCtlIngressJitterThreshold Unsigned32,
jnxPingCtlTrapGeneration BITS,
jnxPingCtlTargetPort InetPortNumber,
jnxPingCtlJseriesHWTimeStamp TruthValue,
jnxPingCtlOneWayHWTimeStamp TruthValue,
jnxPingCtlMovAvgSize Unsigned32,
jnxPingCtlMXseriesHWTimeStamp TruthValue,
jnxPingCtlEXseriesHWTimeStamp TruthValue
}
jnxPingCtlOwnerIndex OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"To facilitate the provisioning of access control by a
security administrator using the View-Based Access
Control Model (RFC 2575, VACM) for tables in which
multiple users may need to independently create or
modify entries, the initial index is used as an 'owner
index'. Such an initial index has a syntax of
SnmpAdminString, and can thus be trivially mapped to a
securityName or groupName as defined in VACM, in
accordance with a security policy.
When used in conjunction with such a security policy all
entries in the table belonging to a particular user (or
group) will have the same value for this initial index.
For a given user's entries in a particular table, the
object identifiers for the information in these entries
will have the same subidentifiers (except for the 'column'
subidentifier) up to the end of the encoded owner index.
To configure VACM to permit access to this portion of the
table, one would create vacmViewTreeFamilyTable entries
with the value of vacmViewTreeFamilySubtree including
the owner index portion, and vacmViewTreeFamilyMask
'wildcarding' the column subidentifier. More elaborate
configurations are possible."
::= { jnxPingCtlEntry 1 }
jnxPingCtlTestName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name of the ping test. This is locally unique, within
the scope of an pingCtlOwnerIndex."
::= { jnxPingCtlEntry 2 }
jnxPingCtlIfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Setting this object to an interface name prior to starting a remote
ping operation directs the ping probes to be transmitted over the
specified interface. To specify the interface index instead, see
pingCtlIfIndex. The interface name must be specified under interfaces
statement of the JUNOS configuration. A zero length string value for
this object means that this option is not enabled. The following
values may be set simultaneously, however, only one value is used.
The precedence order is a follows:
pingCtlIfIndex (see pingCtlTable in pingMIB)
jnxPingCtlIfName
jnxPingCtlRoutingIfIndex (deprecated)
jnxPingCtlRoutingIfName (deprecated)
jnxPingCtlRoutingInstanceName"
DEFVAL { ''H }
::= { jnxPingCtlEntry 3 }
jnxPingCtlRoutingIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Use this option to specify the routing instance used when directing
outgoing ping packets. The interface ifIndex specified should be in
the desired routing instance table. The interface specified will not
necessarily be the interface packets are transmitted on. By default,
the source address of the packets will be set to the address of the
interface chosen. pingCtlSourceAddress should be used to override
the choice for source address if necessary. A value of zero for this
object means that this option is not enabled.
NOTE: deprecated by jnxPingCtlRoutingInstanceName"
DEFVAL { 0 }
::= { jnxPingCtlEntry 4 }
jnxPingCtlRoutingIfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Use this option to specify the routing instance used when directing
outgoing ping packets. The interface name specified should be in
the desired routing instance table. The interface specified will not
necessarily be the interface packets are transmitted on. By default,
the source address of the packets will be set to the address of the
interface chosen. pingCtlSourceAddress should be used to override
the choice for source address if necessary.
NOTE: deprecated by jnxPingCtlRoutingInstanceName"
DEFVAL { ''H }
::= { jnxPingCtlEntry 5 }
jnxPingCtlRoutingInstanceName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use this option to specify the name of the routing instance used when
directing outgoing ping packets. The instance name specified must be
configured under routing-instances of the JUNOS configuration."
DEFVAL { ''H }
::= { jnxPingCtlEntry 6 }
jnxPingCtlRttThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..6000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum round trip time allowed. If this threshold is crossed
by any probe, a jnxPingRttThresholdExceeded trap will be sent."
DEFVAL { 0 }
::= { jnxPingCtlEntry 7 }
jnxPingCtlRttStdDevThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..6000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum round trip time standard deviation allowed over the
course of any test. If the calculated standard deviation of the
round trip time at the end of any test exceeds this threshold,
a jnxPingRttStdDevThresholdExceeded trap will be sent."
DEFVAL { 0 }
::= { jnxPingCtlEntry 8 }
jnxPingCtlRttJitterThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..6000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum allowed jitter in the round trip time over the course
of any test. Jitter is defined as the difference between the
maximum and minimum round trip times measured over the course of
a single test (jnxPingResultsMaxRttUs minus jnxPingResultsMinRttUs).
If the measured jitter exceeds this threshold, a
jnxPingRttJitterThresholdExceeded trap will be sent."
DEFVAL { 0 }
::= { jnxPingCtlEntry 9 }
jnxPingCtlEgressTimeThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..60000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum egress trip time allowed. If this threshold is crossed by
any probe, a jnxPingEgressThresholdExceeded trap will be sent.
This applies only if the probe type (pingCtlType) provides one way
delay measurements. Currently jnxPingIcmpTimeStamp is the only
supported probe type with this property."
DEFVAL { 0 }
::= { jnxPingCtlEntry 10 }
jnxPingCtlEgressStdDevThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..60000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum egress trip time standard deviation allowed over the
course of any test. If the calculated standard deviation of the
egress trip time at the end of any test exceeds this threshold,
a jnxPingEgressStdDevThresholdExceeded trap will be sent.
This applies only if the probe type (pingCtlType) provides one way
delay measurements. Currently jnxPingIcmpTimeStamp is the only
supported probe type with this property."
DEFVAL { 0 }
::= { jnxPingCtlEntry 11 }
jnxPingCtlEgressJitterThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..60000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum allowed jitter in the egress trip time over the course
of any test. Jitter is defined as the difference between the
maximum and minimum egress trip times measured over the course of
a single test (jnxPingResultsMaxSrcDstt minus jnxPingResultsMinSrcDstt).
If the measured jitter exceeds this threshold, a
jnxPingEgressJitterThresholdExceeded trap will be sent.
This applies only if the probe type (pingCtlType) provides one way
delay measurements. Currently jnxPingIcmpTimeStamp is the only
supported probe type with this property."
DEFVAL { 0 }
::= { jnxPingCtlEntry 12 }
jnxPingCtlIngressTimeThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..60000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum ingress trip time allowed. If this threshold is crossed by
any probe, a jnxPingIngressThresholdExceeded trap will be sent.
This applies only if the probe type (pingCtlType) provides one way
delay measurements. Currently jnxPingIcmpTimeStamp is the only
supported probe type with this property."
DEFVAL { 0 }
::= { jnxPingCtlEntry 13 }
jnxPingCtlIngressStddevThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..60000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum ingress trip time standard deviation allowed over the
course of any test. If the calculated standard deviation of the
ingress trip time at the end of any test exceeds this threshold,
a jnxPingIngressStddevThresholdExceeded trap will be sent.
This applies only if the probe type (pingCtlType) provides one way
delay measurements. Currently jnxPingIcmpTimeStamp is the only
supported probe type with this property."
DEFVAL { 0 }
::= { jnxPingCtlEntry 14 }
jnxPingCtlIngressJitterThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..60000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum allowed jitter in the ingress trip time over the course
of any test. Jitter is defined as the difference between the
maximum and minimum ingress trip times measured over the course of
a single test (jnxPingResultsMaxDstSrct minus jnxPingResultsMinDstSrct).
If the measured jitter exceeds this threshold, a
jnxPingIngressJitterThresholdExceeded trap will be sent.
This applies only if the probe type (pingCtlType) provides one way
delay measurements. Currently jnxPingIcmpTimeStamp is the only
supported probe type with this property."
DEFVAL { 0 }
::= { jnxPingCtlEntry 15 }
jnxPingCtlTrapGeneration OBJECT-TYPE
SYNTAX BITS {
rttThreshold(0),
rttStdDevThreshold(1),
rttJitterThreshold(2),
egressThreshold(3),
egressStdDevThreshold(4),
egressJitterThreshold(5),
ingressThreshold(6),
ingressStdDevThreshold(7),
ingressJitterThreshold(8),
maxrttThreshold(9)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object determines when and if
to generate a notification for this entry:
rttThreshold(0) - Generate a jnxPingRttThresholdExceeded
notification when the configured rtt threshold
is exceeded.
rttStdDevThreshold(1) - Generate a jnxPingRttStdDevThresholdExceeded
notification when the configured rtt standard deviation
threshold is exceeded.
rttJitterThreshold(2) - Generate a jnxPingRttJitterThresholdExceeded
notification when the configured rtt jitter threshold
is exceeded.
egressThreshold(3) - Generate a jnxPingEgressThresholdExceeded
notification when the configured egress threshold is exceeded.
This applies only if the probe type supports one way measurments.
egressStdDevThreshold(4) - Generate a
jnxPingEgressStdDevThresholdExceeded notification when the
configured egress standard deviation threshold is exceeded.
This applies only if the probe type supports one way measurments.
egressJitterThreshold(5) - Generate a
jnxPingEgressJitterThresholdExceeded notification when the
configured egress jitter threshold is exceeded.
This applies only if the probe type supports one way measurments.
ingressThreshold(6) - Generate a jnxPingIngressThresholdExceeded
notification when the configured ingress threshold is exceeded.
This applies only if the probe type supports one way measurments.
ingressStdDevThreshold(7) - Generate a
jnxPingIngressStdDevThresholdExceeded notification when the
configured ingress standard deviation threshold is exceeded.
This applies only if the probe type supports one way measurments.
ingressJitterThreshold(8) - Generate a
jnxPingIngressJitterThresholdExceeded notification when the
configured ingress jitter threshold is exceeded.
This applies only if the probe type supports one way measurments.
The value of this object defaults to zero, indicating
that none of the above options have been selected.
maxrttThreshold(9) - Generate a jnxPingMaxRttThresholdExceeded
notification when the configured max rtt threshold
is exceeded."
::= { jnxPingCtlEntry 16 }
jnxPingCtlTargetPort OBJECT-TYPE
SYNTAX InetPortNumber (7 | 49152..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The target UDP/TCP port used by the probe.
When ICMP ping is used, jnxPingCtlTargetPort value will be shown as 0."
::= { jnxPingCtlEntry 17 }
jnxPingCtlJseriesHWTimeStamp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use to enable the RPM Hardware Timestamp feature on J-series routers.
For M/T series routers, use the jnxPingCtlIfName and
pingCtlByPassRouteTable objects to redirect probes to the AS Pic.
For those routers, this object must have the value: false."
DEFVAL { false }
::= { jnxPingCtlEntry 18 }
jnxPingCtlOneWayHWTimeStamp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use this object to enable Hardware Timestamp-based one-way
measurements. If this object is not enabled (ie, set to true),
no Hardware Timestamp based one way measurements or calculations
will be performed for this control entry. This object applies to
all Juniper routers. Note, due to clock synchronization artifacts,
many one-way jitter measurements & calculations may include signifacant
variations, in some cases orders of magnitude greater than the round
trip times."
DEFVAL { false }
::= { jnxPingCtlEntry 19 }
jnxPingCtlMovAvgSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Juniper RPM feature maintains a set of the most recent probe
measurements & provides the same calculations over that collection
as provided over a test (ie, average, standard deviation, etc). This
data is available via the jnx-rpm mib or via the CLI/XML. The
number of samples maintained in this moving collection is specified
by this object. This value must be less than the number of samples
maintained in the history table (ie, pingCtlMaxRows)."
DEFVAL { 0 }
::= { jnxPingCtlEntry 20 }
jnxPingCtlMXseriesHWTimeStamp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use to enable the RPM Hardware Timestamp feature on MX-series routers.
For M/T series routers, use the jnxPingCtlIfName and
pingCtlByPassRouteTable objects to redirect probes to the AS PIC.
For those routers, this object must have the value: false."
DEFVAL { false }
::= { jnxPingCtlEntry 21 }
jnxPingCtlEXseriesHWTimeStamp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use to enable the RPM Hardware Timestamp feature on EX-series switches.
For thoses, this object must have the value: false."
DEFVAL { false }
::= { jnxPingCtlEntry 22 }
jnxPingMaxRttThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..6000000)
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum round trip time allowed. If this threshold is crossed
by any probe of a test, a jnxPingMaxRttThresholdExceeded trap will be sent."
DEFVAL { 0 }
::= { jnxPingCtlEntry 23 }
--
-- Ping Results Table extensions
--
jnxPingResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF JnxPingResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Augments the pingResultsTable with additional data."
::= { jnxPingObjects 3 }
jnxPingResultsEntry OBJECT-TYPE
SYNTAX JnxPingResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides additional ping test results."
AUGMENTS { pingResultsEntry }
::= { jnxPingResultsTable 1 }
JnxPingResultsEntry ::=
SEQUENCE {
jnxPingResultsRttUs Unsigned32,
jnxPingResultsSumRttUs Unsigned32,
jnxPingResultsMinRttUs Unsigned32,
jnxPingResultsMaxRttUs Unsigned32,
jnxPingResultsAvgRttUs Unsigned32,
jnxPingResultsStdDevRttUs Unsigned32,
jnxPingResultsEgressUs Unsigned32,
jnxPingResultsMinEgressUs Unsigned32,
jnxPingResultsMaxEgressUs Unsigned32,
jnxPingResultsAvgEgressUs Unsigned32,
jnxPingResultsStddevEgressUs Unsigned32,
jnxPingResultsIngressUs Unsigned32,
jnxPingResultsMinIngressUs Unsigned32,
jnxPingResultsMaxIngressUs Unsigned32,
jnxPingResultsAvgIngressUs Unsigned32,
jnxPingResultsStddevIngressUs Unsigned32,
jnxPingResultsJitterRttUs Unsigned32,
jnxPingResultsJitterEgressUs Unsigned32,
jnxPingResultsJitterIngressUs Unsigned32,
jnxPingResultsStatus OperationResponseStatus,
jnxPingResultsTime DateAndTime,
jnxPingResultsOwnerIndex SnmpAdminString,
jnxPingResultsTestName SnmpAdminString
}
jnxPingResultsRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The round trip delays measured for the most recent successful probe
during this test. Measured in microseconds."
::= { jnxPingResultsEntry 1 }
jnxPingResultsSumRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of the round trip delays measured for all the probes
during this test. Measured in microseconds."
::= { jnxPingResultsEntry 2 }
jnxPingResultsMinRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum of the round trip delays measured for all the probes
during this test. Measured in microseconds."
::= { jnxPingResultsEntry 3 }
jnxPingResultsMaxRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum of the round trip delays measured for all the probes
during this test. Measured in microseconds."
::= { jnxPingResultsEntry 4 }
jnxPingResultsAvgRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average of the round trip delays measured for all the probes
during this test. Measured in microseconds."
::= { jnxPingResultsEntry 5 }
jnxPingResultsStdDevRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The standard deviation of the round trip delays measured
during this test. Measured in microseconds."
::= { jnxPingResultsEntry 6 }
jnxPingResultsEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The egress trip delays measured for the most recent successful probe
during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 7 }
jnxPingResultsMinEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum of the egress trip delays measured over all
probes during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 8 }
jnxPingResultsMaxEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum of the egress trip delays measured over all
probes during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 9 }
jnxPingResultsAvgEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average of the egress trip delays measured over all
probes during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 10 }
jnxPingResultsStddevEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The standard deviation of the egress trip delays measured over all
probes during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 11 }
jnxPingResultsIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ingress trip delays measured for the most recent successful probe
during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 12 }
jnxPingResultsMinIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum of the ingress trip delays measured for over all
probes during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 13 }
jnxPingResultsMaxIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum of the ingress trip delays measured over all
probes during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 14 }
jnxPingResultsAvgIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average of the ingress trip delays measured over all
probes during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 15 }
jnxPingResultsStddevIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The standard deviation of the ingress trip delays measured over all
probes during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 16 }
jnxPingResultsJitterRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The jitter of the round trip delays measured for all the probes
during this test. Measured in microseconds."
::= { jnxPingResultsEntry 17 }
jnxPingResultsJitterEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The jitter of the egress trip delays measured for all the probes
during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 18 }
jnxPingResultsJitterIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The jitter of the ingress trip delays measured for all the probes
during this test. Measured in microseconds.
This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingResultsEntry 19 }
jnxPingResultsStatus OBJECT-TYPE
SYNTAX OperationResponseStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the most recent probe."
::= { jnxPingResultsEntry 20 }
jnxPingResultsTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp for when the most recent probe result was determined."
::= { jnxPingResultsEntry 21 }
jnxPingResultsOwnerIndex OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object has the same value as pingCtlOwnerIndex and is provided
for those applications that are unable to parse the value of
pingCtlOwnerIndex from the instance portion of the OIDs belonging to
this table."
::= { jnxPingResultsEntry 22 }
jnxPingResultsTestName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object has the same value as pingCtlTestName and is provided
for those applications that are unable to parse the value of
pingCtlTestName from the instance portion of the OIDs belonging to
this table."
::= { jnxPingResultsEntry 23 }
--
-- Ping History Table extensions
--
jnxPingProbeHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF JnxPingProbeHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Augments the pingHistoryTable with additional data."
::= { jnxPingObjects 4 }
jnxPingProbeHistoryEntry OBJECT-TYPE
SYNTAX JnxPingProbeHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides additional ping history data."
AUGMENTS { pingProbeHistoryEntry }
::= { jnxPingProbeHistoryTable 1 }
JnxPingProbeHistoryEntry ::=
SEQUENCE {
jnxPingProbeHistoryResponseUs Unsigned32,
jnxPingProbeHistoryJitterUs Unsigned32,
jnxPingProbeHistoryResponseEgressUs Unsigned32,
jnxPingProbeHistoryResponseIngressUs Unsigned32,
jnxPingProbeHistoryEgressJitterUs Unsigned32,
jnxPingProbeHistoryIngressJitterUs Unsigned32
}
jnxPingProbeHistoryResponseUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time measured in microseconds from when
a probe was sent to when its response was received or
when it timed out. The value of this object is reported
as 0 when it is not possible to transmit a probe."
::= { jnxPingProbeHistoryEntry 1 }
jnxPingProbeHistoryJitterUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time difference measured in microseconds between the maximum
and minimum round trip times. Each history entry provides a running
calculation of the jitter (calculated over the current test) at the
time a probe was completed."
::= { jnxPingProbeHistoryEntry 2 }
jnxPingProbeHistoryResponseEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time measured in microseconds from when
a probe was sent to when it was received by destination.
This applies only if the probe type (pingCtlType) provides one way
delay measurements.
For all other probe types, the value is irrelevant and will return 0."
::= { jnxPingProbeHistoryEntry 3 }
jnxPingProbeHistoryResponseIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time measured in microseconds from when
a probe was sent from the destination to when it was received.
This applies only if the probe type (pingCtlType) provides one way
delay measurements.
For all other probe types, the value is irrelevant and will return 0."
::= { jnxPingProbeHistoryEntry 4 }
jnxPingProbeHistoryEgressJitterUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time difference measured in microseconds between the maximum
and minimum egress trip times. Each history entry provides a running
calculation of the jitter (calculated over the current test) at the
time a probe was completed.
This applies only if the probe type (pingCtlType) provides one way
delay measurements.
For all other probe types, the value is irrelevant and will return 0."
::= { jnxPingProbeHistoryEntry 5 }
jnxPingProbeHistoryIngressJitterUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time difference measured in microseconds between the maximum
and minimum ingress trip times. Each history entry provides a running
calculation of the jitter (calculated over the current test) at the
time a probe was completed.
This applies only if the probe type (pingCtlType) provides one way
delay measurements.
For all other probe types, the value is irrelevant and will return 0."
::= { jnxPingProbeHistoryEntry 6 }
--
-- Last ping test Results Table
--
jnxPingLastTestResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF JnxPingLastTestResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Stores result of the most recently completed test. Entry corresponding
to a test will be created only after completion of first test."
::= { jnxPingObjects 5 }
jnxPingLastTestResultEntry OBJECT-TYPE
SYNTAX JnxPingLastTestResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides most recently completed test result."
INDEX {
jnxPingCtlOwnerIndex,
jnxPingCtlTestName
}
::= { jnxPingLastTestResultTable 1 }
JnxPingLastTestResultEntry ::=
SEQUENCE {
jnxPingLastTestResultProbeResponses Unsigned32,
jnxPingLastTestResultSentProbes Unsigned32,
jnxPingLastTestResultSumRttUs Unsigned32,
jnxPingLastTestResultMinRttUs Unsigned32,
jnxPingLastTestResultMaxRttUs Unsigned32,
jnxPingLastTestResultAvgRttUs Unsigned32,
jnxPingLastTestResultStdDevRttUs Unsigned32,
jnxPingLastTestResultMinEgressUs Unsigned32,
jnxPingLastTestResultMaxEgressUs Unsigned32,
jnxPingLastTestResultAvgEgressUs Unsigned32,
jnxPingLastTestResultStddevEgressUs Unsigned32,
jnxPingLastTestResultMinIngressUs Unsigned32,
jnxPingLastTestResultMaxIngressUs Unsigned32,
jnxPingLastTestResultAvgIngressUs Unsigned32,
jnxPingLastTestResultStddevIngressUs Unsigned32,
jnxPingLastTestResultPeakToPeakJitterRttUs Unsigned32,
jnxPingLastTestResultPeakToPeakJitterEgressUs Unsigned32,
jnxPingLastTestResultPeakToPeakJitterIngressUs Unsigned32,
jnxPingLastTestResultTime DateAndTime
}
jnxPingLastTestResultProbeResponses OBJECT-TYPE
SYNTAX Unsigned32
UNITS "responses"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of responses received in the most recently completed test."
::= { jnxPingLastTestResultEntry 1 }
jnxPingLastTestResultSentProbes OBJECT-TYPE
SYNTAX Unsigned32
UNITS "probes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object reflects the number of probes sent in the
most recently completed test."
::= { jnxPingLastTestResultEntry 2 }
jnxPingLastTestResultSumRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of the round trip delays measured for all the probes
during the most recently completed test. Measured in microseconds."
::= { jnxPingLastTestResultEntry 3 }
jnxPingLastTestResultMinRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum of the round trip delays measured for all the probes
during the most recently completed test. Measured in microseconds."
::= { jnxPingLastTestResultEntry 4 }
jnxPingLastTestResultMaxRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum of the round trip delays measured for all the probes
during the most recently completed test. Measured in microseconds."
::= { jnxPingLastTestResultEntry 5 }
jnxPingLastTestResultAvgRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average of the round trip delays measured for all the probes
during the most recently completed test. Measured in microseconds."
::= { jnxPingLastTestResultEntry 6 }
jnxPingLastTestResultStdDevRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The standard deviation of the round trip delays measured during
the most recently completed test. Measured in microseconds."
::= { jnxPingLastTestResultEntry 7 }
jnxPingLastTestResultMinEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum of the egress trip delays measured over all probes
during the most recently completed test. Measured in microseconds.
This applies only if the probe type (pingCtlType) provides
one-way delay measurements. For all other probe types, their
values are irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 8 }
jnxPingLastTestResultMaxEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum of the egress trip delays measured over all probes
during the most recently completed test. Measured in microseconds.
This applies only if the probe type (pingCtlType) provides
one-way delay measurements. For all other probe types, their
values are irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 9 }
jnxPingLastTestResultAvgEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average of the egress trip delays measured over all probes
during the most recently completed test. Measured in microseconds.
This applies only if the probe type (pingCtlType) provides
one-way delay measurements. For all other probe types, their
values are irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 10 }
jnxPingLastTestResultStddevEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The standard deviation of the egress trip delays measured over all
probes during the most recently completed test. Measured in
microseconds. This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types, their
values are irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 11 }
jnxPingLastTestResultMinIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum of the ingress trip delays measured for over all probes
during the most recently completed test. Measured in microseconds.
This applies only if the probe type (pingCtlType) provides
one-way delay measurements. For all other probe types, their
values are irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 12 }
jnxPingLastTestResultMaxIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum of the ingress trip delays measured over all probes
during the most recently completed test. Measured in microseconds.
This applies only if the probe type (pingCtlType) provides
one-way delay measurements. For all other probe types, their
values are irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 13 }
jnxPingLastTestResultAvgIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average of the ingress trip delays measured over all probes
during the most recently completed test. Measured in microseconds.
This applies only if the probe type (pingCtlType) provides
one-way delay measurements. For all other probe types, their
values are irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 14 }
jnxPingLastTestResultStddevIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The standard deviation of the ingress trip delays measured over all
probes during the most recently completed test. Measured in
microseconds. This applies only if the probe type (pingCtlType)
provides one-way delay measurements. For all other probe types,
their values are irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 15 }
jnxPingLastTestResultPeakToPeakJitterRttUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the difference between the min and max delays over
the course of the last completed test. Measured in microseconds."
::= { jnxPingLastTestResultEntry 16 }
jnxPingLastTestResultPeakToPeakJitterEgressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the difference between the min and max egress trip
delays over the course of the last completed test. Measured in
microseconds. This applies only if the probe type (pingCtlType) provides
one-way delay measurements. For all other probe types, their values are
irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 17 }
jnxPingLastTestResultPeakToPeakJitterIngressUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the difference between the min and max ingress trip
delays over the course of the last completed test. Measured in
microseconds. This applies only if the probe type (pingCtlType) provides
one-way delay measurements. For all other probe types, their values are
irrelevant and will return 0."
::= { jnxPingLastTestResultEntry 18 }
jnxPingLastTestResultTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp for when the last test was completed."
::= { jnxPingLastTestResultEntry 19 }
--
-- Notification definitions
--
jnxPingNotificationPrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"All Juniper-specific ping notifications are registered under
this branch."
::= { jnxPingNotifications 0 }
jnxPingRttThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinRttUs,
jnxPingResultsMaxRttUs,
jnxPingResultsAvgRttUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingResultsLastGoodProbe,
jnxPingCtlRttThreshold,
jnxPingResultsRttUs
}
STATUS current
DESCRIPTION
"This notification is generated when the round trip time
(jnxPingCtlRttThreshold) exceeds the configured
threshold (jnxPingCtlRttThreshold) and the rttThreshold bit is
set in jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 1 }
jnxPingRttStdDevThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinRttUs,
jnxPingResultsMaxRttUs,
jnxPingResultsAvgRttUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingResultsLastGoodProbe,
jnxPingCtlRttStdDevThreshold,
jnxPingResultsStdDevRttUs
}
STATUS current
DESCRIPTION
"This notification is generated when the standard deviation of
the round trip time (jnxPingResultsStdDevRttUs) exceeds the
configured threshold (jnxPingCtlRttStdDevThreshold) and the
rttStdDevThreshold bit is set in jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 2 }
jnxPingRttJitterThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinRttUs,
jnxPingResultsMaxRttUs,
jnxPingResultsAvgRttUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingResultsLastGoodProbe,
jnxPingCtlRttJitterThreshold
}
STATUS current
DESCRIPTION
"This notification is generated when the round trip time jitter
(jnxPingResultsMaxRttUs minus jnxPingResultsMinRttUs) exceeds the
configured threshold (jnxPingCtlRttJitterThreshold) and the
rttJitterThreshold bit is set in jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 3 }
jnxPingEgressThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinEgressUs,
jnxPingResultsMaxEgressUs,
jnxPingResultsAvgEgressUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsLastGoodProbe,
jnxPingCtlEgressTimeThreshold,
jnxPingResultsEgressUs
}
STATUS current
DESCRIPTION
"This notification is generated when the egress time
(jnxPingResultsEgressUs) exceeds the configured
threshold (jnxPingCtlEgressTimeThreshold) and the
egressThreshold bit is set in jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 4 }
jnxPingEgressStdDevThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinEgressUs,
jnxPingResultsMaxEgressUs,
jnxPingResultsAvgEgressUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsLastGoodProbe,
jnxPingResultsStddevEgressUs,
jnxPingCtlEgressStdDevThreshold,
jnxPingResultsStddevEgressUs
}
STATUS current
DESCRIPTION
"This notification is generated when the standard deviation of
the egress time (jnxPingResultsStddevEgressUs) exceeds the
configured threshold (jnxPingCtlEgressStdDevThreshold) and the
egressStdDevThreshold bit is set in jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 5 }
jnxPingEgressJitterThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinEgressUs,
jnxPingResultsMaxEgressUs,
jnxPingResultsAvgEgressUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsLastGoodProbe,
jnxPingCtlEgressJitterThreshold
}
STATUS current
DESCRIPTION
"This notification is generated when the egress time jitter
(jnxPingResultsMaxEgressUs minus jnxPingResultsMinEgressUs)
exceeds the configured threshold (jnxPingCtlEgressJitterThreshold)
and the egressJitterThreshold bit is set in
jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 6 }
jnxPingIngressThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinIngressUs,
jnxPingResultsMaxIngressUs,
jnxPingResultsAvgIngressUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsLastGoodProbe,
jnxPingCtlIngressTimeThreshold,
jnxPingResultsIngressUs
}
STATUS current
DESCRIPTION
"This notification is generated when the ingress time
(jnxPingResultsIngressUs) exceeds the configured
threshold (jnxPingCtlIngressTimeThreshold) and the
ingressThreshold bit is set in jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 7 }
jnxPingIngressStddevThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinIngressUs,
jnxPingResultsMaxIngressUs,
jnxPingResultsAvgIngressUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsLastGoodProbe,
jnxPingResultsStddevIngressUs,
jnxPingCtlIngressStddevThreshold,
jnxPingResultsStddevIngressUs
}
STATUS current
DESCRIPTION
"This notification is generated when the standard deviation of
the ingress time (jnxPingResultsStddevIngressUs) exceeds the
configured threshold (jnxPingCtlIngressStddevThreshold) and the
ingressStdDevThreshold bit is set in jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 8 }
jnxPingIngressJitterThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinIngressUs,
jnxPingResultsMaxIngressUs,
jnxPingResultsAvgIngressUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsLastGoodProbe,
jnxPingCtlIngressJitterThreshold
}
STATUS current
DESCRIPTION
"This notification is generated when the ingress time jitter
(jnxPingResultsMaxIngressUs minus jnxPingResultsMinIngressUs)
exceeds the configured threshold (jnxPingCtlIngressJitterThreshold)
and the ingressJitterThreshold bit is set in
jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 9 }
jnxPingMaxRttThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
jnxPingResultsMinRttUs,
jnxPingResultsMaxRttUs,
jnxPingResultsAvgRttUs,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingResultsLastGoodProbe,
jnxPingCtlRttThreshold,
jnxPingResultsRttUs
}
STATUS current
DESCRIPTION
"This notification is generated when the max round trip time
(jnxPingCtlMaxRttThreshold) exceeds the configured
threshold (jnxPingCtlMaxRttThreshold) and the maxrttThreshold bit is
set in jnxPingCtlTrapGeneration."
::= { jnxPingNotificationPrefix 10 }
END
|