summaryrefslogtreecommitdiff
path: root/MIBS/junose/Juniper-UNI-ATM-MIB
blob: ef2c7a12ea948b65d44a394e286e655ab48deeeb (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
5535
5536
5537
5538
5539
5540
5541
5542
5543
5544
5545
5546
5547
5548
5549
5550
5551
5552
5553
5554
5555
5556
5557
5558
5559
5560
5561
5562
5563
5564
5565
5566
5567
5568
5569
5570
5571
5572
5573
5574
5575
5576
5577
5578
5579
5580
5581
5582
5583
5584
5585
5586
5587
5588
5589
5590
5591
5592
5593
5594
5595
5596
5597
5598
5599
5600
5601
5602
5603
5604
5605
5606
5607
5608
5609
5610
5611
5612
5613
5614
5615
5616
5617
5618
5619
5620
5621
5622
5623
5624
5625
5626
5627
5628
5629
5630
5631
5632
5633
5634
5635
5636
5637
5638
5639
5640
5641
5642
5643
5644
5645
5646
5647
5648
5649
5650
5651
5652
5653
5654
5655
5656
5657
5658
5659
5660
5661
5662
5663
5664
5665
5666
5667
5668
5669
5670
5671
5672
5673
5674
5675
5676
5677
5678
5679
5680
5681
5682
5683
5684
5685
5686
5687
5688
5689
5690
5691
5692
5693
5694
5695
5696
5697
5698
5699
5700
5701
5702
5703
5704
5705
5706
5707
5708
5709
5710
5711
5712
5713
5714
5715
5716
5717
5718
5719
5720
5721
5722
5723
5724
5725
5726
5727
5728
5729
5730
5731
5732
5733
5734
5735
5736
5737
5738
5739
5740
5741
5742
5743
5744
5745
5746
5747
5748
5749
5750
5751
5752
5753
5754
5755
5756
5757
5758
5759
5760
5761
5762
5763
5764
5765
5766
5767
5768
5769
5770
5771
5772
5773
5774
5775
5776
5777
5778
5779
5780
5781
5782
5783
5784
5785
5786
5787
5788
5789
5790
5791
5792
5793
5794
5795
5796
5797
5798
5799
5800
5801
5802
5803
5804
5805
5806
5807
5808
5809
5810
5811
5812
5813
5814
5815
5816
5817
5818
5819
5820
5821
5822
5823
5824
5825
5826
5827
5828
5829
5830
5831
5832
5833
5834
5835
5836
5837
5838
5839
5840
5841
5842
5843
5844
5845
5846
5847
5848
5849
5850
5851
5852
5853
5854
5855
5856
5857
5858
5859
5860
5861
5862
5863
5864
5865
5866
5867
5868
5869
5870
5871
5872
5873
5874
5875
5876
5877
5878
5879
5880
5881
5882
5883
5884
5885
5886
5887
5888
5889
5890
5891
5892
5893
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5904
5905
5906
5907
5908
5909
5910
5911
5912
5913
5914
5915
5916
5917
5918
5919
5920
5921
5922
5923
5924
5925
5926
5927
5928
5929
5930
5931
5932
5933
5934
5935
5936
5937
5938
5939
5940
5941
5942
5943
5944
5945
5946
5947
5948
5949
5950
5951
5952
5953
5954
5955
5956
5957
5958
5959
5960
5961
5962
5963
5964
5965
5966
5967
5968
5969
5970
5971
5972
5973
5974
5975
5976
5977
5978
5979
5980
5981
5982
5983
5984
5985
5986
5987
5988
5989
5990
5991
5992
5993
5994
5995
5996
5997
5998
5999
6000
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6114
6115
6116
6117
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
6148
6149
6150
6151
6152
6153
6154
6155
6156
6157
6158
6159
6160
6161
6162
6163
6164
6165
6166
6167
6168
6169
6170
6171
6172
6173
6174
6175
6176
6177
6178
6179
6180
6181
6182
6183
6184
6185
6186
6187
6188
6189
6190
6191
6192
6193
6194
6195
6196
6197
6198
6199
6200
6201
6202
6203
6204
6205
6206
6207
6208
6209
6210
6211
6212
6213
6214
6215
6216
6217
6218
6219
6220
6221
6222
6223
6224
6225
6226
6227
6228
6229
6230
6231
6232
6233
6234
6235
6236
6237
6238
6239
6240
6241
6242
6243
6244
6245
6246
6247
6248
6249
6250
6251
6252
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296
6297
6298
6299
6300
6301
6302
6303
6304
6305
6306
6307
6308
6309
6310
6311
6312
6313
6314
6315
6316
6317
6318
6319
6320
6321
6322
6323
6324
6325
6326
6327
6328
6329
6330
6331
6332
6333
6334
6335
6336
6337
6338
6339
6340
6341
6342
6343
6344
6345
6346
6347
6348
6349
6350
6351
6352
6353
6354
6355
6356
6357
6358
6359
6360
6361
6362

-- *****************************************************************************
-- Juniper-UNI-ATM-MIB
--
-- Juniper Networks Enterprise MIB
--   ATM MIB
--
-- Copyright (c) 1999 Redstone Communications, Inc.
-- Copyright (c) 1999, 2002 Unisphere Networks, Inc.
-- Copyright (c) 2002, 2005 Juniper Networks, Inc.
--   All Rights Reserved.
-- *****************************************************************************

Juniper-UNI-ATM-MIB  DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32,
    Unsigned32, Counter64, Counter32, IpAddress, TimeTicks
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, RowStatus, TruthValue, TimeStamp, DisplayString
        FROM SNMPv2-TC
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
        FROM SNMPv2-CONF
    InterfaceIndex, InterfaceIndexOrZero, ifIndex
        FROM IF-MIB
    AtmVpIdentifier, AtmVcIdentifier, AtmVorXAdminStatus, AtmAddr
        FROM ATM-TC-MIB
    atmVplVpi, atmVclVpi, atmVclVci
        FROM ATM-MIB
    atmfM4VpTestObject, atmfM4VpTestId, atmfM4VpTestType, atmfM4VpTestResult,
    atmfM4VcTestObject, atmfM4VcTestId, atmfM4VcTestType, atmfM4VcTestResult,
    atmfM4VpTestCode, atmfM4VcTestCode
        FROM ATM-FORUM-SNMP-M4-MIB
    juniMibs
        FROM Juniper-MIBs
    JuniNextIfIndex, JuniEnable, JuniInterfaceLocationType,
    JuniInterfaceLocationValue
        FROM Juniper-TC;

juniAtmMIB  MODULE-IDENTITY
    LAST-UPDATED "200511151133Z"  -- 15-Nov-05 11:33 AM EST - JUNOSe 7.3
    ORGANIZATION "Juniper Networks, Inc."
    CONTACT-INFO
        "       Juniper Networks, Inc.
        Postal: 10 Technology Park Drive
                Westford, MA  01886-3146
                USA
        Tel:    +1 978 589 5800
        Email:  mib@Juniper.net"
    DESCRIPTION
        "The ATM MIB for the Juniper enterprise."
	REVISION "200511151133Z"  -- 15-Nov-05 11:33 AM EST - JUNOSe 7.3
	DESCRIPTION
		"Added ATM VC Class support"
    -- Revision History
    REVISION    "200508171726Z"  -- 17-Aug-05 01:26 PM EDT  - JUNOSe 7.3
    DESCRIPTION
        "Removed support for:
            juniAtmIfSvcSignallingTable
            juniAtmIfPnniRccTable
            juniAtmSubIfAddress
            juniAtmSubIfSvcConfigTable."
    REVISION    "200502172315Z"  -- 17-Feb-05 06:15 PM EST  - JUNOSe 7.1
    DESCRIPTION
        "Added the following to juniAtmCircuitOamTable:
            juniAtmCircuitInOamF5EndToEndLoopbackCmds
            juniAtmCircuitInOamF5EndToEndLoopbackRsps
            juniAtmCircuitInOamF5SegmentLoopbackCmds
            juniAtmCircuitInOamF5SegmentLoopbackRsps
            juniAtmCircuitOutOamF5EndToEndLoopbackCmds
            juniAtmCircuitOutOamF5EndToEndLoopbackRsps
            juniAtmCircuitOutOamF5SegmentLoopbackCmds
            juniAtmCircuitOutOamF5SegmentLoopbackRsps
            juniAtmCircuitOamUpCount
            juniAtmCircuitOamDownCount
            juniAtmCircuitOamRetryFrequency
            juniAtmCircuitOamAlarmDownCount
            juniAtmCircuitOamAlarmClearTimeout
        Added the following to juniAtmF4FlowOamEndToEndStatsTable:
            juniAtmF4FlowEndToEndInLoopbackCmds
            juniAtmF4FlowEndToEndInLoopbackRsps
            juniAtmF4FlowEndToEndOutLoopbackCmds
            juniAtmF4FlowEndToEndOutLoopbackRsps
        Added the following to juniAtmF4FlowOamSegmentStatsTable:
            juniAtmF4FlowSegmentInLoopbackCmds
            juniAtmF4FlowSegmentInLoopbackRsps
            juniAtmF4FlowSegmentOutLoopbackCmds
            juniAtmF4FlowSegmentOutLoopbackRsps"
    REVISION    "200412081522Z"  -- 08-Dec-04 10:22 AM EST  - JUNOSe 7.0
    DESCRIPTION
        "Added aal0 and aal5 values to juniAtmSubIfVccType enumeration.
         Added ATM Martini cell aggregation configuration objects.
         Added profile override support.
         Added bulk-configuration modification support."
    REVISION    "200312301507Z"  -- 25-Feb-04 03:23 PM EST - JUNOSe 6.0
    DESCRIPTION
        "Added second generation E-series platform support:
            Imported JuniInterfaceLocationType and JuniInterfaceLocationValue
            from Juniper-TC to replace JuniAtmLocationType and
            JuniAtmLocationValue textual conventions, respectively."
    REVISION    "200402252023Z"  -- 25-Feb-04 03:23 PM EST  - JUNOSe 5.3
    DESCRIPTION
        "Added support to export the subinterface description to the line
         cards.  Added advisory receive support for subinterfaces."
    REVISION    "200309192201Z"  -- 19-Sep-03 06:01 PM EDT  - JUNOSe 5.2
    DESCRIPTION
        "Added JuniAtmLocationType and JuniAtmLocationValue textual conventions.
         Added juniAtmSubIfLocationType and juniAtmSubIfLocationTable."
    REVISION    "200307141537Z"  -- 14-Jul-03 11:37 AM EDT  - JUNOSe 5.1
    DESCRIPTION
        "Added F4 flow OAM circuit support.
         Added ATM VP description support.
         Added bulk circuit configuration support.
         Corrected enumeration values for UNI signalling versions."
    REVISION    "200301151932Z"  -- 15-Jan-03 02:32 PM EST  - JUNOSe 5.0
    DESCRIPTION
        "Replaced Unisphere names with Juniper names.
         Changed the juniAtmVcPingProbeCount Range to match CLI.
         Added null value for juniAtmSubIfVccType."
    REVISION    "200208091403Z"  -- 09-Aug-02 10:03 AM EDT  - JUNOSe 4.1
    DESCRIPTION
        "Added receive bandwith support to CAC.
         Added E164 public addressing support.
         Added PNNI RCC table support.
         Added ATM1483 interface MTU config support."
    REVISION    "200208091340Z"  -- 09-Aug-02 09:40 AM EDT  - JUNOSe 4.0
    DESCRIPTION
        "Added support for CAC used bandwidth.
         Added ATM switched virtual connection (SVC) support.
         Added juniAtmSubIfAddress to the juniAtmSubIfTable."
    REVISION    "200201241400Z"  -- 24-Jan-02 09:00 AM EST  - JUNOSe 3.4
    DESCRIPTION
        "Added support for connection admission control (CAC)."
    REVISION    "200112141804Z"  -- 14-Dec-01 01:04 PM EST  - JUNOSe 3.3
    DESCRIPTION
        "Added support from ATM traffic shaping."
    REVISION    "200111261639Z"  -- 26-Nov-01 11:39 AM EST  - JUNOSe 3.2
    DESCRIPTION
        "Added support for NBMA map lists.
         Added support for ATM ping.
         Changed juniAtmSubIfVccVcd and juniAtmIfIlmiVcd ranges to
         (0..2147483647).
         Added range to juniAtmIfCapabilityMaxVcd.
         Added rtVbr service catagory to juniAtmSubIfVccTable.
         Added support for OAM cell filter.
         Added PVC counter for reveived unknown protocol."
    REVISION    "200011271951Z"  -- 27-Nov-00 02:51 PM EST  - JUNOSe 3.0
    DESCRIPTION
        "Added autoconfig value for juniAtmSubIfVccType.
         Added in/out summary cell counters.
         Added juniVpTunnelServiceCategory to juniAtmVpTunnelTable.
         Added support for atm interface capability traversal."
    REVISION    "200008020000Z"  -- 02-Aug-00               - JUNOSe 2.3
    DESCRIPTION
        "Added the juniAtmCircuitOamTable."
    REVISION    "200005120000Z"  -- 12-May-00               - JUNOSe 2.0
    DESCRIPTION
        "Added the juniAtmVpTunnelTable."
    REVISION    "200001130000Z"  -- 13-Jan-00               - JUNOSe 1.3
    DESCRIPTION
        "Added the juniAtmPvcStatisticsTable."
    REVISION      "9908040000Z"  -- 04-Aug-99               - JUNOSe 1.1
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { juniMibs 8 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
JuniAtmNbmaMapName  ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "32a"
    STATUS      current
    DESCRIPTION
        "An administratively assigned map name.  Represents textual information
        taken from the NVT ASCII character set.  The name must be unique per
        system."
    REFERENCE
        "RFC 854: NVT ASCII character set.  See SNMPv2-TC.DisplayString
        DESCRIPTION for a summary."
    SYNTAX      OCTET STRING (SIZE(1..32))

JuniAtmNbmaMapNameOrNull  ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "32a"
    STATUS      current
    DESCRIPTION
        "An administratively assigned map name.  Represents textual information
        taken from the NVT ASCII character set.  The name must be unique per
        system.

        Differs from JuniAtmNbmaMapName in that it permits a zero-length
        string."
    REFERENCE
        "RFC 854: NVT ASCII character set.  See SNMPv2-TC.DisplayString
        DESCRIPTION for a summary."
    SYNTAX      OCTET STRING (SIZE(0..32))

JuniAtmLocationType  ::= TEXTUAL-CONVENTION
    STATUS      obsolete
    DESCRIPTION
        "Obsolete description of the platform-dependent interpretation of a
        JuniAtmLocationValue object.  This textual convention has been relpaced
        by Juniper-TC.JuniInterfaceLocationType."
    SYNTAX      INTEGER {
                    unknown(0),
                    slotPort(1) }

JuniAtmLocationValue  ::= TEXTUAL-CONVENTION
    STATUS      obsolete
    DESCRIPTION
        "Obsolete value of a platform-dependent interface location, represented
        as an OCTET STRING.  A corresponding JuniAtmLocationType object
        identified the mapping of octets to location elements, e.g. 'slot.port'.
        This textual convention has been replaced by
        Juniper-TC.JuniInterfaceLocationValue."
    SYNTAX      OCTET STRING (SIZE(1..16))


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniAtmObjects     OBJECT IDENTIFIER ::= { juniAtmMIB 1 }

--
-- This MIB contains managed objects for each of three interface layers:  ATM;
-- AAL5; and ATM Subinterface.  For each of these layers, management objects are
-- provided to query for an available interface index, and to create/delete
-- interfaces of that type.  Creating/deleting these interface types using this
-- MIB has the side effect of creating/deleting corresponding entries in the
-- Interface MIB ifTable/ifXTable, and in the Juniper Enterprise Interface MIB
-- juniIfTable.
--
juniAtmIfLayer        OBJECT IDENTIFIER ::= { juniAtmObjects 1 }
juniAtmAal5IfLayer    OBJECT IDENTIFIER ::= { juniAtmObjects 2 }
juniAtmSubIfLayer     OBJECT IDENTIFIER ::= { juniAtmObjects 3 }
juniAtmNbma           OBJECT IDENTIFIER ::= { juniAtmObjects 4 }
juniAtmPing           OBJECT IDENTIFIER ::= { juniAtmObjects 5 }
juniAtmLocation       OBJECT IDENTIFIER ::= { juniAtmObjects 6 }
juniAtmVcClass 		OBJECT IDENTIFIER ::= { juniAtmObjects 7}

-- /////////////////////////////////////////////////////////////////////////////
--
-- ATM LAYER
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- IfIndex selection for creating new ATM interfaces
--
juniAtmNextIfIndex OBJECT-TYPE
    SYNTAX      JuniNextIfIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Coordinate ifIndex value allocation for entries in juniAtmIfTable.

        A GET of this object returns the next available ifIndex value to be used
        to create an entry in the associated interface table; or zero, if no
        valid ifIndex value is available.  This object also returns a value of
        zero when it is the lexicographic successor of a varbind presented in an
        SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
        that ifIndex allocation is unintended.

        Successive GETs will typically return different values, thus avoiding
        collisions among cooperating management clients seeking to create table
        entries simultaneously."
    ::= { juniAtmIfLayer 1 }

--
-- The ATM Interface Table
--
juniAtmIfTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmIfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM interfaces present in the system."
    ::= { juniAtmIfLayer 2 }

juniAtmIfEntry OBJECT-TYPE
    SYNTAX      JuniAtmIfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics of an ATM interface.
        Creating/deleting entries in this table causes corresponding entries for
        be created/deleted in ifTable/ifXTable/juniIfTable."
    INDEX     { juniAtmIfIndex }
    ::= { juniAtmIfTable 1 }

JuniAtmIfEntry ::= SEQUENCE {
    juniAtmIfIndex                       InterfaceIndex,
    juniAtmIfRowStatus                   RowStatus,
    juniAtmIfLowerIfIndex                InterfaceIndexOrZero,
    juniAtmIfIlmiVpi                     AtmVpIdentifier,
    juniAtmIfIlmiVci                     AtmVcIdentifier,
    juniAtmIfIlmiVcd                     Integer32,
    juniAtmIfIlmiPollFrequency           Integer32,
    juniAtmIfIlmiAdminState              INTEGER,
    juniAtmIfUniVersion                  INTEGER,
    juniAtmIfOamCellRxAdminState         INTEGER,
    juniAtmIfInCells                     Counter64,
    juniAtmIfOutCells                    Counter64,
    juniAtmIfVcCount                     Integer32,
    juniAtmIfMapGroup                    JuniAtmNbmaMapNameOrNull,
    juniAtmIfCacAdminState               JuniEnable,
    juniAtmIfCacUbrWeight                Integer32,
    juniAtmIfCacSubscriptionBandwidth    Integer32,
    juniAtmIfCacAvailableBandwidth       Integer32,
    juniAtmIfCacAvailableBandwidthRx     Integer32,
    juniAtmIfE164Autoconversion          INTEGER,
    juniAtmIfE164Gateway                 INTEGER,
    juniAtmIfE164OneToOneAddrTrans       INTEGER,
    juniAtmIfOamCellFilter               INTEGER,
    juniAtmIfCacUsedBandwidthUpper       Unsigned32,
    juniAtmIfCacUsedBandwidthLower       Unsigned32,
	juniAtmIfAssociatedVcClassId       Unsigned32 }

juniAtmIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM interface.  When creating entries in this table,
        suitable values for this object are determined by reading
        juniAtmNextIfIndex."
    ::= { juniAtmIfEntry 1 }

juniAtmIfRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy

        To create an entry in this table, the following entry objects MUST be
        explicitly configured:
            juniAtmIfRowStatus
            juniAtmIfLowerIfIndex

        In addition, when creating an entry the following condition must hold:
            A value for juniAtmIfIndex must have been determined previously, by
            reading juniAtmNextIfIndex.

        A corresponding entry in ifTable/ifXTable/juniIfTable is created or
        destroyed as a result of creating/destroying an entry in this table."
    ::= { juniAtmIfEntry 2 }

juniAtmIfLowerIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The ifIndex of an interface over which this ATM interface is to be
        layered.  A value of zero indicates no layering.  An implementation may
        choose to require that a nonzero value be configured at entry creation."
    ::= { juniAtmIfEntry 3 }

juniAtmIfIlmiVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The VPI of the ILMI of a major ATM interface."
    DEFVAL    { 0 }
    ::= { juniAtmIfEntry 4 }

juniAtmIfIlmiVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The VCI of the ILMI of a major ATM interface."
    DEFVAL    { 16 }
    ::= { juniAtmIfEntry 5 }

juniAtmIfIlmiVcd OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "An integer identifier for the ILMI, used in conjunction with the
        command-line interface.

        The value must be unique among VCs configured on the same ATM
        interface."
    DEFVAL    { 0 }
    ::= { juniAtmIfEntry 6 }

juniAtmIfIlmiPollFrequency OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The amount of time in seconds between successive transmissions of ILMI
        messages on this interface for the purpose of detecting loss of ILMI
        connectivity.  The distinguished value zero disables ILMI connectivity
        procedures on this interface."
    ::= { juniAtmIfEntry 7 }

juniAtmIfIlmiAdminState OBJECT-TYPE
    SYNTAX      INTEGER {
                    disabled(0),
                    enabled(1) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The administrative status of ILMI in the ATM interface."
    ::= { juniAtmIfEntry 8 }

juniAtmIfUniVersion OBJECT-TYPE
    SYNTAX      INTEGER {
                    uniVersionAutoConfig(0),
                    version3Dot0(1),
                    version3Dot1(2),
                    version4Dot0(3) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Use to specify the User Network Interface (UNI) the router should use
        when ILMI link auto determination is unsuccesful or ILMI is disabled."
    ::= { juniAtmIfEntry 9 }

juniAtmIfOamCellRxAdminState OBJECT-TYPE
    SYNTAX      INTEGER {
                    oamCellAdminStateDisabled(0),
                    oamCellAdminStateEnabled(1) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Use to specify the OAM Cell Receive Administrative state on this
        interface."
    DEFVAL { oamCellAdminStateEnabled }
    ::= { juniAtmIfEntry 10 }

juniAtmIfInCells OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total number of cells received on this major interface."
    ::= { juniAtmIfEntry 11 }

juniAtmIfOutCells OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total number of cells transmitted on this major interface."
    ::= { juniAtmIfEntry 12 }

juniAtmIfVcCount  OBJECT-TYPE
    SYNTAX      Integer32 (0..268431360)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total number of circuits configured on this interface."
    ::= { juniAtmIfEntry 13 }

juniAtmIfMapGroup OBJECT-TYPE
    SYNTAX      JuniAtmNbmaMapNameOrNull
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The NBMA map group this interface is associated with."
    DEFVAL    { "" }
    ::= { juniAtmIfEntry 14 }

juniAtmIfCacAdminState OBJECT-TYPE
    SYNTAX      JuniEnable
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The administrative staus of CAC on this ATM major interface."
    DEFVAL    { disable }
    ::= { juniAtmIfEntry 15 }

juniAtmIfCacUbrWeight OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The bandwidth associated with every UBR and UBR with PCR connection
        configured on the ATM major interface.  This value is used for CAC
        computation.  The units are kilo-bits per second (kbps)."
    DEFVAL    { 0 }
    ::= { juniAtmIfEntry 16 }

juniAtmIfCacSubscriptionBandwidth OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The subscribed bandwidth of the ATM major interface.  If this value is
        not specified or set to 0, the effective port bandwidth is used.  When a
        Get operation is performed the current effective bandwidth is returned.
        The units are kilo-bits per second (kbps)."
    DEFVAL    { 0 }
    ::= { juniAtmIfEntry 17 }

juniAtmIfCacAvailableBandwidth OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The available bandwidth in Tx direction of the ATM major interface.  As
        connections are added or deleted on the interface, this value is
        updated.  The units are kilo-bits per second (kbps)."
    ::= { juniAtmIfEntry 18 }

juniAtmIfCacAvailableBandwidthRx OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION
        "The available bandwidth in Rx direction of the ATM major interface.  As
        connections are added or deleted on the interface, this value is
        updated.  The units are kilo-bits per second (kbps)."
    ::= { juniAtmIfEntry 19 }

juniAtmIfE164Autoconversion OBJECT-TYPE
    SYNTAX      INTEGER {
                    disabled(0),
                    enabled(1) }
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The status of E164 autoconversion feature in the ATM interface."
    ::= { juniAtmIfEntry 20 }

juniAtmIfE164Gateway OBJECT-TYPE
    SYNTAX      INTEGER {
                    disabled(0),
                    enabled(1) }
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The status of E164 gateway feature in the ATM interface."
    ::= { juniAtmIfEntry 21 }

juniAtmIfE164OneToOneAddrTrans OBJECT-TYPE
    SYNTAX      INTEGER {
                    disabled(0),
                    enabled(1) }
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The status of E164 one-to-one address translation feature in the ATM
        interface."
    ::= { juniAtmIfEntry 22 }

juniAtmIfOamCellFilter OBJECT-TYPE
    SYNTAX      INTEGER {
                    oamCellFilterAll(0),
                    oamCellFilterAlarm(1) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The type of OAM cells to discard when juniAtmIfOamCellRxAdminState is
        set to oamCellAdminStateDisabled.  The value oamCellFilterAlarm discards
        received OAM AIS and RDI cells.  The value oamCellFilterAll discards all
        received OAM cells.  Note that when juniAtmIfOamCellRxAdminState is set
        to oamCellAdminStateEnabled, this object has no effect."
    DEFVAL    { oamCellFilterAll }
    ::= { juniAtmIfEntry 23 }

juniAtmIfCacUsedBandwidthUpper OBJECT-TYPE
    SYNTAX       Unsigned32
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The most significant 32 bits of the CAC used bandwidth on the ATM major
        interface.  The least significant 32 bits of the CAC used bandwidth are
        specified by juniAtmIfCacUsedBandwidthLower."
    ::= { juniAtmIfEntry 24 }

juniAtmIfCacUsedBandwidthLower OBJECT-TYPE
    SYNTAX       Unsigned32
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The least significant 32 bits of the CAC used bandwidth on the ATM
        major interface.  The most significant 32 bits of the CAC used bandwidth
        are specified by juniAtmIfCacUsedBandwidthUpper."
    ::= { juniAtmIfEntry 25 }

juniAtmIfAssociatedVcClassId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
"The integer identifier of the ATM VC class associated with this ATM interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface."
DEFVAL    { 0 }
    ::= { juniAtmIfEntry 26 }


--
-- The ATM VPI/VCI Statistics Table
--
juniAtmPvcStatisticsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmPvcStatisticsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains statistics for PVC entries."
    ::= { juniAtmIfLayer 3 }

juniAtmPvcStatisticsEntry OBJECT-TYPE
    SYNTAX      JuniAtmPvcStatisticsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry provides statistics on an ATM PVC."
    INDEX     { juniAtmPvcStatsIfIndex,
                juniAtmPvcStatsVpi,
                juniAtmPvcStatsVci }
    ::= { juniAtmPvcStatisticsTable 1 }

JuniAtmPvcStatisticsEntry ::= SEQUENCE {
    juniAtmPvcStatsIfIndex                       InterfaceIndex,
    juniAtmPvcStatsVpi                           AtmVpIdentifier,
    juniAtmPvcStatsVci                           AtmVcIdentifier,
    juniAtmPvcStatsInCells                       Counter64,
    juniAtmPvcStatsInCellOctets                  Counter64,
    juniAtmPvcStatsInPackets                     Counter64,
    juniAtmPvcStatsInPacketOctets                Counter64,
    juniAtmPvcStatsOutCells                      Counter64,
    juniAtmPvcStatsOutCellOctets                 Counter64,
    juniAtmPvcStatsOutPackets                    Counter64,
    juniAtmPvcStatsOutPacketOctets               Counter64,
    juniAtmPvcStatsInCellErrors                  Counter32,
    juniAtmPvcStatsinPacketErrors                Counter32,
    juniAtmPvcStatsOutCellErrors                 Counter32,
    juniAtmPvcStatsOutPacketErrors               Counter32,
    juniAtmPvcStatsInPacketDiscards              Counter32,
    juniAtmPvcStatsInPacketOctetDiscards         Counter32,
    juniAtmPvcStatsInPacketUnknownProtocol       Counter32 }

juniAtmPvcStatsIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM interface."
    ::= { juniAtmPvcStatisticsEntry 1 }

juniAtmPvcStatsVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VPI of the ATM VCC used by this ATM interface and PVC."
    ::= { juniAtmPvcStatisticsEntry 2 }

juniAtmPvcStatsVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VCI of the ATM VCC used by this ATM interface and PVC."
    ::= { juniAtmPvcStatisticsEntry 3 }

juniAtmPvcStatsInCells OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received cells."
    ::= { juniAtmPvcStatisticsEntry 4 }

juniAtmPvcStatsInCellOctets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received cells octets."
    ::= { juniAtmPvcStatisticsEntry 5 }

juniAtmPvcStatsInPackets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received AAL PDUs."
    ::= { juniAtmPvcStatisticsEntry 6 }

juniAtmPvcStatsInPacketOctets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received AAL PDU octets."
    ::= { juniAtmPvcStatisticsEntry 7 }

juniAtmPvcStatsOutCells OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted cells."
    ::= { juniAtmPvcStatisticsEntry 8 }

juniAtmPvcStatsOutCellOctets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted cell octets."
    ::= { juniAtmPvcStatisticsEntry 9 }

juniAtmPvcStatsOutPackets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted AAL PDUs."
    ::= { juniAtmPvcStatisticsEntry 10 }

juniAtmPvcStatsOutPacketOctets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted AAL PDU octets."
    ::= { juniAtmPvcStatisticsEntry 11 }

juniAtmPvcStatsInCellErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received cells dropped due to errors."
    ::= { juniAtmPvcStatisticsEntry 12 }

juniAtmPvcStatsinPacketErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received packets dropped due to errors."
    ::= { juniAtmPvcStatisticsEntry 13 }

juniAtmPvcStatsOutCellErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Cells not transmitted due to errors."
    ::= { juniAtmPvcStatisticsEntry 14 }

juniAtmPvcStatsOutPacketErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Packets not transmitted due to errors."
    ::= { juniAtmPvcStatisticsEntry 15 }

juniAtmPvcStatsInPacketDiscards OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received packets w/o errors discarded."
    ::= { juniAtmPvcStatisticsEntry 16 }

juniAtmPvcStatsInPacketOctetDiscards OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received bytes w/o errors discarded."
    ::= { juniAtmPvcStatisticsEntry 17 }

juniAtmPvcStatsInPacketUnknownProtocol OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received packets that are discarded because the interface can not
        discern or is not configured to support this protocol."
    ::= { juniAtmPvcStatisticsEntry 18 }

--
-- The ATM Virtual Path Tunnel Table
--
juniAtmVpTunnelTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmVpTunnelEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM VP Tunnels present in the system."
    ::= { juniAtmIfLayer 4 }

juniAtmVpTunnelEntry OBJECT-TYPE
    SYNTAX      JuniAtmVpTunnelEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics of an ATM VP Tunnel."
    INDEX     { juniAtmVpTunnelIfIndex,
                juniAtmVpTunnelVpi }
    ::= { juniAtmVpTunnelTable 1 }

JuniAtmVpTunnelEntry ::= SEQUENCE {
    juniAtmVpTunnelIfIndex           InterfaceIndex,
    juniAtmVpTunnelVpi               AtmVpIdentifier,
    juniAtmVpTunnelKbps              Integer32,
    juniAtmVpTunnelRowStatus         RowStatus,
    juniAtmVpTunnelServiceCategory   INTEGER }

juniAtmVpTunnelIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM interface.  The value of this object is the same
        as the juniAtmIfIndex object in the juniAtmIfTable.

        Entries in this table cannot be created unless the underlying ATM
        interface entry is created first in the juniAtmIfTable."
    ::= { juniAtmVpTunnelEntry 1 }

juniAtmVpTunnelVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VPI value for this VP tunnel entry."
    ::= { juniAtmVpTunnelEntry 2 }

juniAtmVpTunnelKbps OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The tunnel rate in kilobits per second (kbps) for this entry."
    ::= { juniAtmVpTunnelEntry 3 }

juniAtmVpTunnelRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy

        To create an entry in this table, the following entry objects MUST be
        explicitly configured:
            juniAtmVpTunnelRowStatus
            juniAtmVpTunnelKbps

        In addition, when creating an entry the following condition must hold:
            A correponding juniAtmVpTunnelIfIndex value must have been created
            in the juniAtmIfTable previously."
    ::= { juniAtmVpTunnelEntry 4 }

juniAtmVpTunnelServiceCategory OBJECT-TYPE
    SYNTAX      INTEGER {
                    nrtVbr(1),
                    cbr(2) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The ATM service category for the tunnel."
    ::= { juniAtmVpTunnelEntry 5 }


--
-- The ATM Interface Capability Table
--
juniAtmIfCapabilityTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmIfCapabilityEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM interfaces present in the system."
    ::= { juniAtmIfLayer 5 }

juniAtmIfCapabilityEntry OBJECT-TYPE
    SYNTAX      JuniAtmIfCapabilityEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the capabilities of an ATM interface.  A
        management client can use this table to determine differences in the
        configurable level of support across entries in this table."
    INDEX     { juniAtmIfCapabilityIndex }
    ::= { juniAtmIfCapabilityTable 1 }

JuniAtmIfCapabilityEntry ::= SEQUENCE {
    juniAtmIfCapabilityIndex             InterfaceIndex,
    juniAtmIfCapabilityTrafficShaping    TruthValue,
    juniAtmIfCapabilityOam               TruthValue,
    juniAtmIfCapabilityDefaultVcPerVp    Integer32,
    juniAtmIfCapabilityNumVpiVciBits     Integer32,
    juniAtmIfCapabilityMaxVcd            Integer32,
    juniAtmIfCapabilityMaxVpi            AtmVpIdentifier,
    juniAtmIfCapabilityMaxVci            AtmVcIdentifier,
    juniAtmIfCapabilityOamCellFilter     TruthValue }

juniAtmIfCapabilityIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM interface.  The value of this object is the same
        as juniAtmIfIndex in the juniAtmIfTable."
    ::= { juniAtmIfCapabilityEntry 1 }

juniAtmIfCapabilityTrafficShaping OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates whether traffic shaping is supported on this interface;
        true(1) indicates that it is, false(2) indicates that it is not."
    ::= { juniAtmIfCapabilityEntry 2 }

juniAtmIfCapabilityOam OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates whether OAM is supported on this interface; true(1) indicates
        that it is, false(2) indicates that it is not."
    ::= { juniAtmIfCapabilityEntry 3 }

juniAtmIfCapabilityDefaultVcPerVp OBJECT-TYPE
    SYNTAX      Integer32 (0..65536)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The default number of VCs per VP for this interface."
    ::= { juniAtmIfCapabilityEntry 4 }

juniAtmIfCapabilityNumVpiVciBits OBJECT-TYPE
    SYNTAX      Integer32 (8..28)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total range of bits used for constructing VPI/VCI identifiers for
        this interface."
    ::= { juniAtmIfCapabilityEntry 5 }

juniAtmIfCapabilityMaxVcd OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The maximum configurable value for a VCD on this interface."
    ::= { juniAtmIfCapabilityEntry 6 }

juniAtmIfCapabilityMaxVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The maximum configurable value for a VPI on this interface."
    ::= { juniAtmIfCapabilityEntry 7 }

juniAtmIfCapabilityMaxVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The maximum configurable value for a VCI on this interface."
    ::= { juniAtmIfCapabilityEntry 8 }

juniAtmIfCapabilityOamCellFilter OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates whether OAM cell filter is supported on this interface;
        true(1) indicates that it is, false(2) indicates that it is not."
    ::= { juniAtmIfCapabilityEntry 9 }


--
-- The juniAtmIfSvcSignallingTable extends the juniAtmIfTable for ATM switched
-- virtual connections (SVCs).
--
juniAtmIfSvcSignallingTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmIfSvcSignallingEntry
    MAX-ACCESS  not-accessible
    STATUS      deprecated
    DESCRIPTION
        "This table contains entries for extending the juniAtmIfTable for
        configuring signalling information for switched virtual connection
        (SVC)."
    ::= { juniAtmIfLayer 6 }

juniAtmIfSvcSignallingEntry OBJECT-TYPE
    SYNTAX      JuniAtmIfSvcSignallingEntry
    MAX-ACCESS  not-accessible
    STATUS      deprecated
    DESCRIPTION
        "Each entry provides configuration parameters for ATM signalling on the
        interface."
    INDEX     { juniAtmIfIndex }
    ::= { juniAtmIfSvcSignallingTable 1 }

JuniAtmIfSvcSignallingEntry ::= SEQUENCE {
    juniAtmIfSvcSignallingVpi            AtmVpIdentifier,
    juniAtmIfSvcSignallingVci            AtmVcIdentifier,
    juniAtmIfSvcSignallingVcd            Integer32,
    juniAtmIfSvcSignallingAdminStatus    AtmVorXAdminStatus }

juniAtmIfSvcSignallingVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  read-write
    STATUS      deprecated
    DESCRIPTION
        "The VPI identifier of the ATM circuit used for signalling for this
        interface."
    DEFVAL    { 0 }
    ::= { juniAtmIfSvcSignallingEntry 1 }

juniAtmIfSvcSignallingVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  read-write
    STATUS      deprecated
    DESCRIPTION
        "The VCI identifier of the ATM circuit used for signalling for this
        interface."
    DEFVAL    { 5 }
    ::= { juniAtmIfSvcSignallingEntry 2 }

juniAtmIfSvcSignallingVcd OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-write
    STATUS      deprecated
    DESCRIPTION
        "An integer identifier for the ATM circuit used for signalling on this
        interface."
    DEFVAL    { 0 }
    ::= { juniAtmIfSvcSignallingEntry 3 }

juniAtmIfSvcSignallingAdminStatus OBJECT-TYPE
    SYNTAX      AtmVorXAdminStatus
    MAX-ACCESS  read-write
    STATUS      deprecated
    DESCRIPTION
        "The administrative status of signalling on the ATM interface."
    ::= { juniAtmIfSvcSignallingEntry 4 }


--
-- The juniAtmIfPnniRccTable extends the juniAtmIfTable for PNNI Routing
-- Control Channel
--
juniAtmIfPnniRccTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmIfPnniRccEntry
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "This table contains entries for extending the juniAtmIfTable for
        configuring PNNI RCC information."
    ::= { juniAtmIfLayer 7 }

juniAtmIfPnniRccEntry OBJECT-TYPE
    SYNTAX      JuniAtmIfPnniRccEntry
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "Each entry provides configuration parameters for PNNI RCC on the
        interface."
    INDEX     { juniAtmIfIndex }
    ::= { juniAtmIfPnniRccTable 1 }

JuniAtmIfPnniRccEntry ::= SEQUENCE {
    juniAtmIfPnniRccVpi            AtmVpIdentifier,
    juniAtmIfPnniRccVci            AtmVcIdentifier,
    juniAtmIfPnniRccVcd            Integer32,
    juniAtmIfPnniRccAdminStatus    AtmVorXAdminStatus }

juniAtmIfPnniRccVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  read-write
    STATUS      obsolete
    DESCRIPTION
        "The VPI identifier of the ATM circuit used for PNNI RCC on this
        interface."
    DEFVAL    { 0 }
    ::= { juniAtmIfPnniRccEntry 1 }

juniAtmIfPnniRccVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  read-write
    STATUS      obsolete
    DESCRIPTION
        "The VCI identifier of the ATM circuit used for PNNI RCC on this
        interface."
    DEFVAL    { 18 }
    ::= { juniAtmIfPnniRccEntry 2 }

juniAtmIfPnniRccVcd OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-write
    STATUS      obsolete
    DESCRIPTION
        "An integer identifier for the ATM circuit used for PNNI RCC on this
        interface."
    DEFVAL    { 0 }
    ::= { juniAtmIfPnniRccEntry 3 }

juniAtmIfPnniRccAdminStatus OBJECT-TYPE
    SYNTAX      AtmVorXAdminStatus
    MAX-ACCESS  read-write
    STATUS      obsolete
    DESCRIPTION
        "The administrative status of PNNI on the ATM interface."
    ::= { juniAtmIfPnniRccEntry 4 }


--
-- The juniAtmOamF4FlowEndToEndConfigTable
--
juniAtmOamF4FlowEndToEndCfgTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmOamF4FlowEndToEndCfgEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for F4 OAM end-to-end flows configured."
    ::= { juniAtmIfLayer 8 }

juniAtmOamF4FlowEndToEndCfgEntry OBJECT-TYPE
    SYNTAX      JuniAtmOamF4FlowEndToEndCfgEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry provides configuration parameters for one F4 OAM end-to-end
        flow configured for each VPI."
    INDEX     { juniAtmOamF4FlowEndToEndIfIndex,
                juniAtmOamF4FlowEndToEndVpi }
    ::= { juniAtmOamF4FlowEndToEndCfgTable 1 }

JuniAtmOamF4FlowEndToEndCfgEntry ::= SEQUENCE {
    juniAtmOamF4FlowEndToEndIfIndex       InterfaceIndex,
    juniAtmOamF4FlowEndToEndVpi           Integer32,
    juniAtmOamF4FlowEndToEndLoopbackTimer Integer32,
    juniAtmOamF4FlowEndToEndCCSink        TruthValue,
    juniAtmOamF4FlowEndToEndCCSource      TruthValue,
    juniAtmOamF4FlowEndToEndRowStatus     RowStatus }

juniAtmOamF4FlowEndToEndIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM interface to configure the F4 OAM end-to-end
        flow."
    ::= { juniAtmOamF4FlowEndToEndCfgEntry 1 }

juniAtmOamF4FlowEndToEndVpi OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Select the VPI for F4 OAM end-to-end flow configuration."
    ::= { juniAtmOamF4FlowEndToEndCfgEntry 2 }

juniAtmOamF4FlowEndToEndLoopbackTimer OBJECT-TYPE
    SYNTAX      Integer32 (-1..600)
    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Configure the timer for sending the F4 flow end-to-end loopback OAM
        cells. Setting this value will enable sending the F4 end cells on the
        circuit.  It is not allowed to set the value to -1 and whenever it is
        read as -1 that means sending end loopback is not enabled.  Setting the
        loopback timer, other than -1, will enable sending the end cells."
    DEFVAL    { -1 }
    ::= { juniAtmOamF4FlowEndToEndCfgEntry 3 }

juniAtmOamF4FlowEndToEndCCSink OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Enable/Disable F4 flow end-to-end continuity check sink end point for
        this VP."
    DEFVAL    { false }
    ::= { juniAtmOamF4FlowEndToEndCfgEntry 4 }

juniAtmOamF4FlowEndToEndCCSource OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Enable/Disable F4 flow end-to-end continuity check source end point for
        this VP."
    DEFVAL    { false }
    ::= { juniAtmOamF4FlowEndToEndCfgEntry 5 }

juniAtmOamF4FlowEndToEndRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy

        To create/delete an entry in this table, the following entry objects
        MUST be explicitly configured:
            juniAtmOamF4FlowEndToEndRowStatus

        F4 OAM end loopback and CC tests are mutually exclusive, enabling one
        will disable the other automatically.  So, it is not allowed either at
        the circuit creation time or after the circuit creation to issue a
        request to enable end-to-end loopback and CC tests simultaneouly.
        Enabling/disabling CC sink and source is one time operation.  To
        re-enable either CC source and sink in way different to earlier, both
        has to be disabled from the previous."
    ::= { juniAtmOamF4FlowEndToEndCfgEntry 6 }


--
-- The juniAtmOamF4FlowSegmentConfigTable
--
juniAtmOamF4FlowSegmentCfgTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmOamF4FlowSegmentCfgEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for F4 OAM Segment flows configured."
    ::= { juniAtmIfLayer 9 }

juniAtmOamF4FlowSegmentCfgEntry OBJECT-TYPE
    SYNTAX      JuniAtmOamF4FlowSegmentCfgEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry provides configuration parameters for one F4 OAM Segment
        flow configured for each VPI."
    INDEX     { juniAtmOamF4FlowSegmentIfIndex,
                juniAtmOamF4FlowSegmentVpi }
    ::= { juniAtmOamF4FlowSegmentCfgTable 1 }

JuniAtmOamF4FlowSegmentCfgEntry ::= SEQUENCE {
    juniAtmOamF4FlowSegmentIfIndex       InterfaceIndex,
    juniAtmOamF4FlowSegmentVpi           Integer32,
    juniAtmOamF4FlowSegmentCCSink        TruthValue,
    juniAtmOamF4FlowSegmentCCSource      TruthValue,
    juniAtmOamF4FlowSegmentRowStatus     RowStatus }

juniAtmOamF4FlowSegmentIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM interface to configure the F4 OAM segment flow."
    ::= { juniAtmOamF4FlowSegmentCfgEntry 1 }

juniAtmOamF4FlowSegmentVpi OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Select the VPI for F4 OAM segment flow configuration."
    ::= { juniAtmOamF4FlowSegmentCfgEntry 2 }

juniAtmOamF4FlowSegmentCCSink OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Enable/Disable F4 flow segment continuity check sink end point for
        this VP."
    DEFVAL    { false }
    ::= { juniAtmOamF4FlowSegmentCfgEntry 3 }

juniAtmOamF4FlowSegmentCCSource OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Enable/Disable F4 flow segment continuity check source end point for
        this VP."
    DEFVAL    { false }
    ::= { juniAtmOamF4FlowSegmentCfgEntry 4 }

juniAtmOamF4FlowSegmentRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy

        To create/delete an entry in this table, the following entry objects
        MUST be explicitly configured:
            juniAtmOamF4FlowSegmentRowStatus

        Enabling/disabling CC sink and source is one time operation.  To
        re-enable either CC source and sink in way different to earlier, both
        has to be disabled from the previous.  F4 OAM segment loopback test is
        not supported."
    ::= { juniAtmOamF4FlowSegmentCfgEntry 5 }


--
-- juniAtmVpDescrTable
--
juniAtmVpDescrTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmVpDescrEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM VP Description present in the
        system.  The user can configure a description of up to 32 characters for
        every VP in the ATM interface.  A row exists for every VP on the ATM
        interface.  These rows get created as soon as the ATM major interface
        created."
    ::= { juniAtmIfLayer 10 }

juniAtmVpDescrEntry OBJECT-TYPE
    SYNTAX      JuniAtmVpDescrEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry contains the description of the VP."
    INDEX     { ifIndex,
                atmVplVpi }
    ::= { juniAtmVpDescrTable 1 }

JuniAtmVpDescrEntry ::= SEQUENCE {
    juniAtmVpDescription     SnmpAdminString }

juniAtmVpDescription OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE(0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The description for this VP.  The default value of this object is null
        string."
    DEFVAL    { "" }
    ::= { juniAtmVpDescrEntry 1 }


--
-- The juniAtmF4FlowOamEndToEndStatsTable
--
juniAtmF4FlowOamEndToEndStatsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmF4FlowOamEndToEndStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for F4 flow EndToEnd OAM circuits stats."
    ::= { juniAtmIfLayer 11 }

juniAtmF4FlowOamEndToEndStatsEntry OBJECT-TYPE
    SYNTAX      JuniAtmF4FlowOamEndToEndStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry provides stats for one F4 OAM circuit for each VPI."
    INDEX     { juniAtmOamF4FlowEndToEndIfIndex,
                juniAtmOamF4FlowEndToEndVpi }
    ::= { juniAtmF4FlowOamEndToEndStatsTable 1 }

JuniAtmF4FlowOamEndToEndStatsEntry ::= SEQUENCE {
    juniAtmF4FlowInOamEndAisCells             Counter32,
    juniAtmF4FlowInOamEndRdiCells             Counter32,
    juniAtmF4FlowInOamEndCCCells              Counter32,
    juniAtmF4FlowInOamEndCCActDeActCells      Counter32,
    juniAtmF4FlowInOamEndLoopbackCells        Counter32,
    juniAtmF4FlowOutEndRdiCells               Counter32,
    juniAtmF4FlowOutEndCCCells                Counter32,
    juniAtmF4FlowOutEndCCActDeActCells        Counter32,
    juniAtmF4FlowOutEndToEndLoopbackCells     Counter32,
    juniAtmF4FlowEndActualLoopbackFreq        Integer32,
    juniAtmF4FlowEndLastTimeChanged           TimeTicks,
    juniAtmF4FlowOamEndVpOperationState       INTEGER,
    juniAtmF4FlowOamEndVpAdminState           INTEGER,
    juniAtmF4FlowEndInOamCells                Counter32,
    juniAtmF4FlowEndOutOamCells               Counter32,
    juniAtmF4FlowEndInOamCellsDropped         Counter32,
    juniAtmF4FlowEndToEndInLoopbackCmds       Counter32,
    juniAtmF4FlowEndToEndInLoopbackRsps       Counter32,
    juniAtmF4FlowEndToEndOutLoopbackCmds      Counter32,
    juniAtmF4FlowEndToEndOutLoopbackRsps      Counter32 }

juniAtmF4FlowInOamEndAisCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 AIS cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 1 }

juniAtmF4FlowInOamEndRdiCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 RDI cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 2 }

juniAtmF4FlowInOamEndCCCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 CC cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 3 }

juniAtmF4FlowInOamEndCCActDeActCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 activation/de-activation cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 4 }

juniAtmF4FlowInOamEndLoopbackCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total received OAM F4 end-to-end loopback cells. Aggregate of
         juniAtmF4FlowEndToEndInLoopbackCmds and
         juniAtmF4FlowEndToEndInLoopbackRsps"
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 5 }

juniAtmF4FlowOutEndRdiCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted end-to-end OAM F4 RDI cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 6 }

juniAtmF4FlowOutEndCCCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted end-to-end OAM F4 CC cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 7 }

juniAtmF4FlowOutEndCCActDeActCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted end-to-end OAM F4 activation/de-activation cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 8 }

juniAtmF4FlowOutEndToEndLoopbackCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total transmitted OAM F4 end-to-end loopback cells. Aggregate of
         juniAtmF4FlowEndToEndOutLoopbackCmds and
         juniAtmF4FlowEndToEndOutLoopbackRsps"
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 9 }

juniAtmF4FlowEndActualLoopbackFreq OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Actual end-to-end loopback Frequecy calculated for OAM cells
        transmission."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 10 }

juniAtmF4FlowEndLastTimeChanged OBJECT-TYPE
    SYNTAX      TimeTicks
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Last time end-to-end F4 OAM flow got changed."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 11 }

juniAtmF4FlowOamEndVpOperationState OBJECT-TYPE
    SYNTAX      INTEGER {
                    vcAisState(0),
                    vcRdiState(1),
                    vcDownRetry(2),
                    vcUpRetry(3),
                    vcUp(4),
                    vcDown(5),
                    vcNotManaged(6),
                    vpAisState(7),
                    vpRdiState(8),
                    vcInVpRdiState(9),
                    vcInVpAisState(10),
                    vcSegmentAisState(11),
                    vcSegRdiState(12) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Represents the F4 end-to-end OAM flow VP operation states.  It can take
        one of the following operational state values:
            vcAisState        - AIS cell received or underlying physical layer
                                reporting transmission path AIS.
            vcRdiState        - RDI cell received.
            vcDownRetry       - OAM loopback failed, using retry frequency to
                                verify that the VC is really down.
            vcUpRetry         - OAM loopback successful, using retry frequency
                                to verify that the VC is really up.
            vcUp              - OAM loopback successful after up retry
                                verification.
            vcDown            - OAM loopback failed after down retry
                                verification.
            vcNotManaged      - No verification via loopback cells being
                                performed.
            vpAisState        - State when F4 AIS cell is received.
            vpRdiState        - State when F4 RDI cell is received.
            vcInVpRdiState    - The data vc is down as a result of VP failure
                                thorugh F4 Rdi oam cell.
            vcInVpAisState    - The data vc is down as a result of VP failure
                                through F4  Ais oam cell.
            vcSegmentAisState - Segment AIS cell received.
            vcSegRdiState     - Segment RDI cell received."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 12 }

juniAtmF4FlowOamEndVpAdminState OBJECT-TYPE
    SYNTAX      INTEGER {
                    down(0),
                    up(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "End-to-end VP admin state."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 13 }

juniAtmF4FlowEndInOamCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 loopback cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 14 }

juniAtmF4FlowEndOutOamCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted end-to-end OAM F4 loopback cells."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 15 }

juniAtmF4FlowEndInOamCellsDropped OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM cells that were dropped."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 16 }

juniAtmF4FlowEndToEndInLoopbackCmds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F4 end-to-end loopback commands."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 17 }

juniAtmF4FlowEndToEndInLoopbackRsps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F4 end-to-end loopback responses."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 18 }

juniAtmF4FlowEndToEndOutLoopbackCmds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F4 end-to-end loopback commands."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 19 }

juniAtmF4FlowEndToEndOutLoopbackRsps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F4 end-to-end loopback responses."
    ::= { juniAtmF4FlowOamEndToEndStatsEntry 20 }


--
-- The juniAtmF4FlowOamSegmentStatsTable
--
juniAtmF4FlowOamSegmentStatsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmF4FlowOamSegmentStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for F4 flow Segment OAM circuits stats."
    ::= { juniAtmIfLayer 12 }

juniAtmF4FlowOamSegmentStatsEntry OBJECT-TYPE
    SYNTAX      JuniAtmF4FlowOamSegmentStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry provides stats for one F4 OAM circuit for each VPI."
    INDEX     { juniAtmOamF4FlowSegmentIfIndex,
                juniAtmOamF4FlowSegmentVpi }
    ::= { juniAtmF4FlowOamSegmentStatsTable 1 }

JuniAtmF4FlowOamSegmentStatsEntry ::= SEQUENCE {
    juniAtmF4FlowInOamSegmentAisCells             Counter32,
    juniAtmF4FlowInOamSegmentRdiCells             Counter32,
    juniAtmF4FlowInOamSegmentCCCells              Counter32,
    juniAtmF4FlowInOamSegmentCCActDeActCells      Counter32,
    juniAtmF4FlowInOamSegmentLoopbackCells        Counter32,
    juniAtmF4FlowOutSegmentRdiCells               Counter32,
    juniAtmF4FlowOutSegmentCCCells                Counter32,
    juniAtmF4FlowOutSegmentCCActDeActCells        Counter32,
    juniAtmF4FlowOutSegmentLoopbackCells          Counter32,
    juniAtmF4FlowSegmentLastTimeChanged           TimeTicks,
    juniAtmF4FlowOamSegmentVpOperationState       INTEGER,
    juniAtmF4FlowOamSegmentVpAdminState           INTEGER,
    juniAtmF4FlowSegmentInOamCells                Counter32,
    juniAtmF4FlowSegmentOutOamCells               Counter32,
    juniAtmF4FlowSegmentInOamCellsDropped         Counter32,
    juniAtmF4FlowSegmentInLoopbackCmds            Counter32,
    juniAtmF4FlowSegmentInLoopbackRsps            Counter32,
    juniAtmF4FlowSegmentOutLoopbackCmds           Counter32,
    juniAtmF4FlowSegmentOutLoopbackRsps           Counter32 }

juniAtmF4FlowInOamSegmentAisCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 AIS cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 1 }

juniAtmF4FlowInOamSegmentRdiCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 RDI cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 2 }

juniAtmF4FlowInOamSegmentCCCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 CC cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 3 }

juniAtmF4FlowInOamSegmentCCActDeActCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 activation/de-activation cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 4 }

juniAtmF4FlowInOamSegmentLoopbackCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total received OAM F4 segment loopback cells. Aggregate of
         juniAtmF4FlowSegmentInLoopbackCmds and
         juniAtmF4FlowSegmentInLoopbackRsps"
    ::= { juniAtmF4FlowOamSegmentStatsEntry 5 }

juniAtmF4FlowOutSegmentRdiCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted end-to-end OAM F4 RDI cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 6 }

juniAtmF4FlowOutSegmentCCCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted end-to-end OAM F4 CC cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 7 }

juniAtmF4FlowOutSegmentCCActDeActCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted end-to-end OAM F4 activation/de-activation cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 8 }

juniAtmF4FlowOutSegmentLoopbackCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total transmitted OAM F4 segment loopback cells. Aggregate of
         juniAtmF4FlowSegmentOutLoopbackCmds and
         juniAtmF4FlowSegmentOutLoopbackRsps"
    ::= { juniAtmF4FlowOamSegmentStatsEntry 9 }

juniAtmF4FlowSegmentLastTimeChanged OBJECT-TYPE
    SYNTAX      TimeTicks
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Last time end-to-end F4 OAM flow got changed."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 10 }

juniAtmF4FlowOamSegmentVpOperationState OBJECT-TYPE
    SYNTAX      INTEGER {
                    vcAisState(0),
                    vcRdiState(1),
                    vcDownRetry(2),
                    vcUpRetry(3),
                    vcUp(4),
                    vcDown(5),
                    vcNotManaged(6),
                    vpAisState(7),
                    vpRdiState(8),
                    vcInVpRdiState(9),
                    vcInVpAisState(10),
                    vcSegmentAisState(11),
                    vcSegRdiState(12) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Represents the F4 end-to-end OAM flow VP operation states.  It can take
        one of the following operational state values:
            vcAisState        - AIS cell received or underlying physical layer
                                reporting transmission path AIS.
            vcRdiState        - RDI cell received.
            vcDownRetry       - OAM loopback failed, using retry frequency to
                                verify that the VC is really down.
            vcUpRetry         - OAM loopback successful, using retry frequency
                                to verify that the VC is really up.
            vcUp              - OAM loopback successful after up retry
                                verification.
            vcDown            - OAM loopback failed after down retry
                                verification.
            vcNotManaged      - No verification via loopback cells being
                                performed.
            vpAisState        - State when F4 AIS cell is received.
            vpRdiState        - State when F4 RDI cell is received.
            vcInVpRdiState    - The data vc is down as a result of VP failure
                                thorugh F4 Rdi oam cell.
            vcInVpAisState    - The data vc is down as a result of VP failure
                                through F4  Ais oam cell.
            vcSegmentAisState - Segment AIS cell received.
            vcSegRdiState     - Segment RDI cell received."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 11 }

juniAtmF4FlowOamSegmentVpAdminState OBJECT-TYPE
    SYNTAX      INTEGER {
                    down(0),
                    up(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Segment VP admin state."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 12 }

juniAtmF4FlowSegmentInOamCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM F4 loopback cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 13 }

juniAtmF4FlowSegmentOutOamCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted end-to-end OAM F4 loopback cells."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 14 }

juniAtmF4FlowSegmentInOamCellsDropped OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received end-to-end OAM cells that were dropped."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 15 }

juniAtmF4FlowSegmentInLoopbackCmds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F4 segment loopback commands."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 16 }

juniAtmF4FlowSegmentInLoopbackRsps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F4 segment loopback responses."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 17 }

juniAtmF4FlowSegmentOutLoopbackCmds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F4 segment loopback commands."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 18 }

juniAtmF4FlowSegmentOutLoopbackRsps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F4 segment loopback responses."
    ::= { juniAtmF4FlowOamSegmentStatsEntry 19 }


--
-- juniAtmMartiniTimeoutTimerTable
--
juniAtmMartiniTimeoutTimerTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmMartiniTimeoutTimerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM Martini cell aggregation timeout
        detection.  The user can configure timeout values for three timers.
        A row exists for every separate timer supported.  These rows get 
        created as soon as the ERX system comes up."
    ::= { juniAtmIfLayer 13 }

juniAtmMartiniTimeoutTimerEntry OBJECT-TYPE
    SYNTAX      JuniAtmMartiniTimeoutTimerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry contains the timeout value of ATM Martini 
        cell aggregation timer."
    INDEX     { juniAtmMartiniTimeoutTimerIndex }
    ::= { juniAtmMartiniTimeoutTimerTable 1 }

JuniAtmMartiniTimeoutTimerEntry ::= SEQUENCE {
    juniAtmMartiniTimeoutTimerIndex       INTEGER,
    juniAtmMartiniTimeoutTimerValue       Integer32 }

juniAtmMartiniTimeoutTimerIndex OBJECT-TYPE
    SYNTAX      INTEGER {
                        timer1(1),
                        timer2(2),
                        timer3(3) }
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ATM Martini cell aggregation timeout timer identifier."
    ::= { juniAtmMartiniTimeoutTimerEntry 1 }

juniAtmMartiniTimeoutTimerValue OBJECT-TYPE
    SYNTAX      Integer32 (100..4095)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The ATM Martini cell aggregation timeout timer value in microseconds."
    DEFVAL    { 100 }
    ::= { juniAtmMartiniTimeoutTimerEntry 2 }

-- ///////////////////
-- ATM VP Statistics 
--
-- //////////////////
--
-- juniAtmVpStatsTable
--
juniAtmVpStatsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmVpStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM VP statistics present in the
        system. A row exists for every VP on the ATM
        interface. These rows get created as soon as the ATM major interface
        created."
    ::= { juniAtmIfLayer 14 }

juniAtmVpStatsEntry OBJECT-TYPE
    SYNTAX      JuniAtmVpStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry contain the VP statistics."
    INDEX     { ifIndex,
                atmVplVpi }
    ::= { juniAtmVpStatsTable 1 }

JuniAtmVpStatsEntry ::= SEQUENCE {	
      juniAtmVpStatsIfIndex                       InterfaceIndex,
      juniAtmVpStatsVpi                           AtmVpIdentifier,
	  juniAtmVpStatsInCells                       Counter64,
	  juniAtmVpStatsInPackets                     Counter64,
	  juniAtmVpStatsInPacketOctets                Counter64,
	  juniAtmVpStatsOutCells                      Counter64,
	  juniAtmVpStatsOutPackets                    Counter64,
	  juniAtmVpStatsOutPacketOctets               Counter64,
	  juniAtmVpStatsInPacketErrors                Counter32,
	  juniAtmVpStatsOutPacketErrors               Counter32,
	  juniAtmVpStatsInPacketDiscards              Counter32,
	  juniAtmVpStatsInPacketOctetDiscards         Counter32,
	  juniAtmVpStatsInPacketUnknownProtocol       Counter32,
	  juniAtmVpStatsCrcErrors                     Counter32,
	  juniAtmVpStatsSarTimeouts                   Counter32,
	  juniAtmVpStatsOverSizedPackets              Counter32
}

juniAtmVpStatsIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM interface."
    ::= { juniAtmVpStatsEntry 1 }

juniAtmVpStatsVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VPI value of the virtual path for which statistics are retrieved."
    ::= { juniAtmVpStatsEntry 2 }


juniAtmVpStatsInCells OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received cells."
    ::= { juniAtmVpStatsEntry 3 }

juniAtmVpStatsInPackets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received AAL5 PDUs."
    ::= { juniAtmVpStatsEntry 4 }

juniAtmVpStatsInPacketOctets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received AAL5 PDU octets."
    ::= { juniAtmVpStatsEntry 5 }

juniAtmVpStatsOutCells OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted cells."
    ::= { juniAtmVpStatsEntry 6 }

juniAtmVpStatsOutPackets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted AAL5 PDUs"
    ::= { juniAtmVpStatsEntry 7 }

juniAtmVpStatsOutPacketOctets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted AAL5 PDU octets."
    ::= { juniAtmVpStatsEntry 8 }

juniAtmVpStatsInPacketErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received packets dropped due to errors."
    ::= { juniAtmVpStatsEntry 9 }


juniAtmVpStatsOutPacketErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Packets not transmitted due to errors."
    ::= { juniAtmVpStatsEntry 10 }
juniAtmVpStatsInPacketDiscards OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received packets without errors discarded."
    ::= { juniAtmVpStatsEntry 11 }

juniAtmVpStatsInPacketOctetDiscards OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received bytes without errors discarded."
    ::= { juniAtmVpStatsEntry 12 }

juniAtmVpStatsInPacketUnknownProtocol OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received packets that are discarded because the interface can not
        discern or is not configured to support this protocol."
    ::= { juniAtmVpStatsEntry 13 }

juniAtmVpStatsCrcErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received packets that are discarded because of check sum erros"
    ::= { juniAtmVpStatsEntry 14 }

juniAtmVpStatsSarTimeouts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received packets that are discarded because of SAR timeout"
    ::= { juniAtmVpStatsEntry 15 }

juniAtmVpStatsOverSizedPackets OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Over sized packets that are received on this VP."
    ::= { juniAtmVpStatsEntry 16 }




-- /////////////////////////////////////////////////////////////////////////////
--
-- AAL5 LAYER
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- IfIndex selection for creating new ATM AAL5 interfaces
--
juniAtmAal5NextIfIndex OBJECT-TYPE
    SYNTAX      JuniNextIfIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Coordinate ifIndex value allocation for entries in juniAtmAal5IfTable.

        A GET of this object returns the next available ifIndex value to be used
        to create an entry in the associated interface table; or zero, if no
        valid ifIndex value is available.  This object also returns a value of
        zero when it is the lexicographic successor of a varbind presented in an
        SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
        that ifIndex allocation is unintended.

        Successive GETs will typically return different values, thus avoiding
        collisions among cooperating management clients seeking to create table
        entries simultaneously."
    ::= { juniAtmAal5IfLayer 1 }


--
-- The ATM AAL5 Interface Table
--
juniAtmAal5IfTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmAal5IfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM AAL5 interfaces present in the
        system."
    ::= { juniAtmAal5IfLayer 2 }

juniAtmAal5IfEntry OBJECT-TYPE
    SYNTAX      JuniAtmAal5IfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics of an ATM AAL5 interface.
        Creating/deleting entries in this table causes corresponding entries for
        be created/deleted in ifTable/ifXTable/juniIfTable."
    INDEX     { juniAtmAal5IfIndex }
    ::= { juniAtmAal5IfTable 1 }

JuniAtmAal5IfEntry ::= SEQUENCE {
    juniAtmAal5IfIndex           InterfaceIndex,
    juniAtmAal5IfRowStatus       RowStatus,
    juniAtmAal5IfLowerIfIndex    InterfaceIndexOrZero }

juniAtmAal5IfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM AAL5 interface.  When creating entries in this
        table, suitable values for this object are determined by reading
        juniAtmAal5NextIfIndex."
    ::= { juniAtmAal5IfEntry 1 }

juniAtmAal5IfRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy

        To create an entry in this table, the following entry objects MUST be
        explicitly configured:
            juniAtmAal5IfRowStatus
            juniAtmAal5IfLowerIfIndex

        In addition, when creating an entry the following condition must hold:
            A value for juniAtmAal5IfIndex must have been determined previously,
            by reading juniAtmAal5NextIfIndex.

        A corresponding entry in ifTable/ifXTable/juniIfTable is created or
        destroyed as a result of creating/destroying an entry in this table."
    ::= { juniAtmAal5IfEntry 2 }

juniAtmAal5IfLowerIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The ifIndex of an ATM interface over which this ATM AAL5 interface is
        to be layered.  A value of zero indicates no layering.  An
        implementation may choose to require that a nonzero value be configured
        at entry creation."
    ::= { juniAtmAal5IfEntry 3 }


--
-- ATM Bulk Circuites Name Table
--
juniAtmBulkCircuitsNameTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmBulkCircuitsNameEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The entries in this table provide mappings of ATM bulk virtual circuit
        range names to local integer identifiers for those profiles.  These
        integers are used as indexes into other MIB tables containing profile
        configuration parameters associated with the same profile name."
    ::= { juniAtmAal5IfLayer 3 }

juniAtmBulkCircuitsNameEntry OBJECT-TYPE
    SYNTAX      JuniAtmBulkCircuitsNameEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A mapping of a ATM bulk virtual circuit range name to an integer
        identifier for that name."
    INDEX     { juniAtmBulkCircuitsNameAal5IfIndex,
                juniAtmBulkCircuitsNameName }
    ::= { juniAtmBulkCircuitsNameTable 1 }

JuniAtmBulkCircuitsNameEntry ::= SEQUENCE {
    juniAtmBulkCircuitsNameAal5IfIndex        InterfaceIndex,
    juniAtmBulkCircuitsNameName               DisplayString,
    juniAtmBulkCircuitsNameRowStatus          RowStatus,
    juniAtmBulkCircuitsNameId                 Unsigned32 }

juniAtmBulkCircuitsNameAal5IfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM AAL5 interface."
    ::= { juniAtmBulkCircuitsNameEntry 1 }

juniAtmBulkCircuitsNameName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(1..80))
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ATM bulk virtual circuit range name uniquely identifying this
        entry."
    ::= { juniAtmBulkCircuitsNameEntry 2 }

juniAtmBulkCircuitsNameRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table.  Only the values
        'createAndGo' and 'destroy' may be SET.

        Creating an entry in this table creates corresponding entry in
        juniAtmBulkCircuitsIdTable. Deleting an entry in this table deletes
        corresponding entries in juniAtmBulkCircuitsIdTable, 
        juniAtmBulkCircuitsTable and 
        juniAtmProfileOverrideAssignIfCircuitTable."
    ::= { juniAtmBulkCircuitsNameEntry 3 }

juniAtmBulkCircuitsNameId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The integer identifier associated with this ATM bulk virtual circuit
        range name.

        This value of this identifier is assigned by the device when an entry in
        this table is created."
    ::= { juniAtmBulkCircuitsNameEntry 4 }


--
-- ATM Bulk Circuits ID Table
--
juniAtmBulkCircuitsIdTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmBulkCircuitsIdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Provides inverse mapping of ATM bulk virtual circuit IDs to ATM bulk
        virtual circuit names."
    ::= { juniAtmAal5IfLayer 4 }

juniAtmBulkCircuitsIdEntry OBJECT-TYPE
    SYNTAX      JuniAtmBulkCircuitsIdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A mapping of an integer identifier to a ATM bulk virtual circuit name."
    INDEX     { juniAtmBulkCircuitsIdAal5IfIndex,
                juniAtmBulkCircuitsIdId }
    ::= { juniAtmBulkCircuitsIdTable 1 }

JuniAtmBulkCircuitsIdEntry ::= SEQUENCE {
    juniAtmBulkCircuitsIdAal5IfIndex        InterfaceIndex,
    juniAtmBulkCircuitsIdId                 Unsigned32,
    juniAtmBulkCircuitsIdName               DisplayString,
    juniAtmBulkCircuitsIdNextInstance       Unsigned32 }

juniAtmBulkCircuitsIdAal5IfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM AAL5 interface."
    ::= { juniAtmBulkCircuitsIdEntry 1 }

juniAtmBulkCircuitsIdId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The integer identifier associated with this ATM bulk virtual circuit
        name."
    ::= { juniAtmBulkCircuitsIdEntry 2 }

juniAtmBulkCircuitsIdName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(1..80))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ATM bulk virtual circuit name having the associated identifier."
    ::= { juniAtmBulkCircuitsIdEntry 3 }

juniAtmBulkCircuitsIdNextInstance OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The next available instance value for juniAtmBulkCircuitsEntry."
    ::= { juniAtmBulkCircuitsIdEntry 4 }


--
-- ATM Bulk Circuits Table
--
juniAtmBulkCircuitsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmBulkCircuitsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains bulk virtual circuit range parameters."
    ::= { juniAtmAal5IfLayer 5 }

juniAtmBulkCircuitsEntry OBJECT-TYPE
    SYNTAX      JuniAtmBulkCircuitsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics of VC range."
    INDEX     { juniAtmBulkCircuitsAal5IfIndex,
                juniAtmBulkCircuitsId,
                juniAtmBulkCircuitsInstance }
    ::= { juniAtmBulkCircuitsTable 1 }

JuniAtmBulkCircuitsEntry ::= SEQUENCE {
    juniAtmBulkCircuitsAal5IfIndex  InterfaceIndex,
    juniAtmBulkCircuitsId           Unsigned32,
    juniAtmBulkCircuitsInstance     Unsigned32,
    juniAtmBulkCircuitsRowStatus    RowStatus,
    juniAtmBulkCircuitsMinVpi       AtmVpIdentifier,
    juniAtmBulkCircuitsMaxVpi       AtmVpIdentifier,
    juniAtmBulkCircuitsMinVci       AtmVcIdentifier,
    juniAtmBulkCircuitsMaxVci       AtmVcIdentifier,
    juniAtmBulkCircuitsAdminState   JuniEnable }

juniAtmBulkCircuitsAal5IfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM AAL5 interface on which this bulk virtual
        circuit sub-range is created."
    ::= { juniAtmBulkCircuitsEntry 1 }

juniAtmBulkCircuitsId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The integer identifier associated with this ATM bulk virtual circuit
        name."
    ::= { juniAtmBulkCircuitsEntry 2 }

juniAtmBulkCircuitsInstance OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The unique identifier of the ATM bulk virtual circuit sub-range."
    ::= { juniAtmBulkCircuitsEntry 3 }

juniAtmBulkCircuitsRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table.  Only the values
        'createAndGo' and 'destroy' may be SET.

        Since none of the VPI/VCI minimum and maximum values have default
        values, all these values must be specified before setting RowStatus to
        'createAndGo'.  The VPI/VCI minimum and maximum values can only be
        configured upon creation.

        Deleting an entry in this table deletes corresponding entries in 
        juniAtmProfileOverrideAssignIfCircuitTable."
    ::= { juniAtmBulkCircuitsEntry 4 }

juniAtmBulkCircuitsMinVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The minimum value of VPI for this circuit sub-range. This value must
        be less than or equal to the value of juniAtmBulkCircuitsMaxVpi."
    ::= { juniAtmBulkCircuitsEntry 5 }

juniAtmBulkCircuitsMaxVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The maximum value of VPI for this cicuit sub-range. This value must
        be equal to or greater than the value of juniAtmBulkCircuitsMinVpi."
    ::= { juniAtmBulkCircuitsEntry 6 }

juniAtmBulkCircuitsMinVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The minimum value of VCI for this circuit sub-range. This value must
        be less than or equal to the value of juniAtmBulkCircuitsMaxVci."
    ::= { juniAtmBulkCircuitsEntry 7 }

juniAtmBulkCircuitsMaxVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The maximum value of VCI for this circuit sub-range. This value must
        be equal to or greater than the value of juniAtmBulkCircuitsMinVci."
    ::= { juniAtmBulkCircuitsEntry 8 }

juniAtmBulkCircuitsAdminState OBJECT-TYPE
    SYNTAX      JuniEnable
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The administrative status of this circuit sub-range."
    DEFVAL      { enable }
    ::= { juniAtmBulkCircuitsEntry 9 }



--
-- Assign overriding profile to interface/vpi/vci.
--
juniAtmProfileOverrideAssignIfCircuitTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmProfileOverrideAssignIfCircuitEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table providing overriding profile assignment to a circuit configured 
        as part of bulk-configuration. Circuit is identified by interface index 
        and vpi, vci.

        The entries in this table specify which profile to use when creating and
        configuring a dynamic interface above a circuit specified by vpi and 
        vci.

        This entry is effective when the circuit specified by 
        juniAtmProfileOverrideAssignIfCircuitAal5Index, 
        juniAtmProfileOverrideAssignIfCircuitRangeId,             
        juniAtmProfileOverrideAssignIfCircuitVpi, 
        juniAtmProfileOverrideAssignIfCircuitVci 
		is part of bulk-configuration."
    ::= { juniAtmAal5IfLayer 6 }

juniAtmProfileOverrideAssignIfCircuitEntry OBJECT-TYPE
    SYNTAX      JuniAtmProfileOverrideAssignIfCircuitEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
	    "An assignment of a profile to a circuit configured as part of 
        bulk-configuration on an AAL5 interface."
    INDEX     { juniAtmProfileOverrideAssignIfCircuitAal5Index,
                juniAtmProfileOverrideAssignIfCircuitRangeId,
                juniAtmProfileOverrideAssignIfCircuitVpi,
                juniAtmProfileOverrideAssignIfCircuitVci }
    ::= { juniAtmProfileOverrideAssignIfCircuitTable 1 }

JuniAtmProfileOverrideAssignIfCircuitEntry ::= SEQUENCE {
    juniAtmProfileOverrideAssignIfCircuitAal5Index           InterfaceIndex,
    juniAtmProfileOverrideAssignIfCircuitRangeId             Unsigned32,
    juniAtmProfileOverrideAssignIfCircuitVpi                 AtmVpIdentifier,
    juniAtmProfileOverrideAssignIfCircuitVci                 AtmVcIdentifier,
    juniAtmProfileOverrideAssignIfCircuitRowStatus           RowStatus,
    juniAtmProfileOverrideAssignIfCircuitProfileId           Unsigned32,
    juniAtmProfileOverrideAssignIfCircuitOperStatus          INTEGER }

juniAtmProfileOverrideAssignIfCircuitAal5Index OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the AAL5 interface to which the profile is assigned."
    ::= { juniAtmProfileOverrideAssignIfCircuitEntry 1 }

juniAtmProfileOverrideAssignIfCircuitRangeId  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The integer identifier associated with the ATM bulk circuit 
        configuration." 
    ::= { juniAtmProfileOverrideAssignIfCircuitEntry 2 }    

juniAtmProfileOverrideAssignIfCircuitVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VPI value of the circuit to which the profile is assigned."
    ::= { juniAtmProfileOverrideAssignIfCircuitEntry 3 }

juniAtmProfileOverrideAssignIfCircuitVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VCI value of the circuit to which the profile is assigned." 
    ::= { juniAtmProfileOverrideAssignIfCircuitEntry 4 }


juniAtmProfileOverrideAssignIfCircuitRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table.  Only the values
        'createAndGo' and 'destroy' may be SET.

        Since the VPI, VCI and profileId values do not have any default
        values, all these values must be specified before setting RowStatus to
        'createAndGo'.  The VPI, VCI and profileId values can only be
        configured upon creation.  None of these values can be modified except
        by deleting the entry."
    ::= { juniAtmProfileOverrideAssignIfCircuitEntry 5 }

juniAtmProfileOverrideAssignIfCircuitProfileId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The ID of the profile assigned to the circuit configured as part of 
        bulk-configuration. Circuit is identified by interface index and vpi, 
        vci."
    ::= { juniAtmProfileOverrideAssignIfCircuitEntry 6 }

juniAtmProfileOverrideAssignIfCircuitOperStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    inactive(0),
                    active(1)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The operational status of the profile override assignment identified
        by this entry.

        It returns inactive(0), if a static ATM circuit with identical VPI/VCI 
        values is present on the same ATM interface. In this case, this
        profile override will not be used to configure upper dynamic 
        interfaces.

        It returns active(1), if no static ATM circuit with identical VPI/VCI 
        values is present on the same ATM interface. In this case, this 
        profile override will be used to configure upper dynamic interfaces."
     ::= { juniAtmProfileOverrideAssignIfCircuitEntry 7 } 


-- /////////////////////////////////////////////////////////////////////////////
--
-- ATM SUBINTERFACE LAYER
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- IfIndex selection for creating new ATM Subinterfaces
--
juniAtmSubIfNextIfIndex OBJECT-TYPE
    SYNTAX      JuniNextIfIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Coordinate ifIndex value allocation for entries in juniAtmSubIfTable.

        A GET of this object returns the next available ifIndex value to be used
        to create an entry in the associated interface table; or zero, if no
        valid ifIndex value is available.  This object also returns a value of
        zero when it is the lexicographic successor of a varbind presented in an
        SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
        that ifIndex allocation is unintended.

        Successive GETs will typically return different values, thus avoiding
        collisions among cooperating management clients seeking to create table
        entries simultaneously."
    ::= { juniAtmSubIfLayer 1 }

--
-- The ATM Subinterface Table
--
juniAtmSubIfTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmSubIfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM Subinterfaces present in the
        system."
    ::= { juniAtmSubIfLayer 2 }

juniAtmSubIfEntry OBJECT-TYPE
    SYNTAX      JuniAtmSubIfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics of an ATM Subinterface.
        Creating/deleting entries in this table causes corresponding entries for
        be created/deleted in ifTable/ifXTable/juniIfTable."
    INDEX     { juniAtmSubIfIndex }
    ::= { juniAtmSubIfTable 1 }

JuniAtmSubIfEntry ::= SEQUENCE {
    juniAtmSubIfIndex                     InterfaceIndex,
    juniAtmSubIfRowStatus                 RowStatus,
    juniAtmSubIfDistinguisher             Integer32,
    juniAtmSubIfLowerIfIndex              InterfaceIndexOrZero,
    juniAtmSubIfNbma                      TruthValue,
    juniAtmSubIfAddress                   AtmAddr,
    juniAtmSubIfMtu                       Integer32,
    juniAtmSubIfAdvisoryRxSpeed           Integer32,
    juniAtmSubIfMartiniMaxCellsPerPacket  Integer32,
    juniAtmSubIfMartiniTimeoutTimerId     Integer32,
	juniAtmSubIfAssociatedVcClassId	  	Unsigned32
 }

juniAtmSubIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM Subinterface.  When creating entries in this
        table, suitable values for this object are determined by reading
        juniAtmSubNextIfIndex."
    ::= { juniAtmSubIfEntry 1 }

juniAtmSubIfRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy

        To create an entry in this table, the following entry objects MUST be
        explicitly configured:
            juniAtmSubIfRowStatus
            juniAtmSubIfLowerIndex

        In addition, when creating an entry the following condition must hold:
            A value for juniAtmSubIfIndex must have been determined previously,
            by reading juniAtmSubIfNextIfIndex.

        A corresponding entry in ifTable/ifXTable/juniIfTable is created or
        destroyed as a result of creating/destroying an entry in this table."
    ::= { juniAtmSubIfEntry 2 }

juniAtmSubIfDistinguisher OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "An integer identifier for the subinterface, used in conjunction with
        the command-line interface.  It is provided here for cross-reference
        purposes only.

        The value must be unique among subinterfaces configured on the same
        underlying ATM adaptation layer.  The upper bound for the value is
        further constrained to be identical with the maximum number of
        subinterfaces supported by the lower interface.

        If this object is not configured, a value will be allocated internally
        and can be queried after table entry creation has succeeded."
    ::= { juniAtmSubIfEntry 3 }

juniAtmSubIfLowerIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The ifIndex of an ATM AAL5 interface over which this ATM subinterface
        is to be layered.  A value of zero indicates no layering.  An
        implementation may choose to require that a nonzero value be configured
        at entry creation."
    ::= { juniAtmSubIfEntry 4 }

juniAtmSubIfNbma OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The NBMA administrative setting.  Setting this value of this object to
        true(1) will enable multipoint access on this interface.  Setting the
        value to false(2), will enable point to point access on this interface."
    DEFVAL    { false }
    ::= { juniAtmSubIfEntry 5 }

juniAtmSubIfAddress OBJECT-TYPE
    SYNTAX      AtmAddr (SIZE(0|7|20))
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Specifies the local ATM NSAP address of the circuit.  A GET operation
        returns a full 20-octet NSAP.  A SET operation only requires 7 octets,
        since the prefix can be implied."
    DEFVAL    { ''H }
    ::= { juniAtmSubIfEntry 6 }

juniAtmSubIfMtu OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The size of the largest packet which can be sent/received on the
        interface, specified in octets."
    DEFVAL    { 9180 }
       ::= { juniAtmSubIfEntry 7 }

juniAtmSubIfAdvisoryRxSpeed OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Advisory receive speed, in kilobits per second (kbps),
        of this subinterface. This object has no impact on
        forwarding performance but may be used as a hint for
        underlying circuit receive speed."
    DEFVAL    { 0 }
       ::= { juniAtmSubIfEntry 8 }

juniAtmSubIfMartiniMaxCellsPerPacket OBJECT-TYPE
    SYNTAX      Integer32 (1..190)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The number of cells that can be aggregated in a single ATM Martini
        packet in cell-relay mode."
    DEFVAL    { 1 }
       ::= { juniAtmSubIfEntry 9 }

juniAtmSubIfMartiniTimeoutTimerId OBJECT-TYPE
    SYNTAX      Integer32 (1..3)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The timer identifier used to abandon cell aggregation when no
        cells are supplied for transmission in ATM Martini cell-relay mode."
    DEFVAL    { 1 }
       ::= { juniAtmSubIfEntry 10 }

juniAtmSubIfAssociatedVcClassId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
		"The integer identifier of the ATM VC class associated with this ATM 
		sub interface. A value for this identifier is determined by locating or 
		creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 
		means no VC class association exists for this interface."
    DEFVAL    { 0 }
    ::= { juniAtmSubIfEntry 11 }


--
-- The ATM Subinterface VCC Table
--
juniAtmSubIfVccTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmSubIfVccEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM VCCs configured on ATM
        subinterfaces present in the system.

        An implementation may constrain the number of VCCs permitted to be
        configured per ATM Subinterface; in particular, an implementation may
        restrict each ATM Subinterface to have a single VCC.

        Attributes in this entry can only be configured at entry creation, and
        remain fixed for the lifetime of the entry."
    ::= { juniAtmSubIfLayer 3 }

juniAtmSubIfVccEntry OBJECT-TYPE
    SYNTAX      JuniAtmSubIfVccEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics of an ATM subinterface VCC."
    INDEX     { juniAtmSubIfIndex,
                juniAtmSubIfVccVpi,
                juniAtmSubIfVccVci }
    ::= { juniAtmSubIfVccTable 1 }

JuniAtmSubIfVccEntry ::= SEQUENCE {
    juniAtmSubIfVccVpi               		AtmVpIdentifier,
    juniAtmSubIfVccVci               		AtmVcIdentifier,
    juniAtmSubIfVccRowStatus         		RowStatus,
    juniAtmSubIfVccVcd               		Integer32,
    juniAtmSubIfVccType              		INTEGER,
    juniAtmSubIfVccServiceCategory   		INTEGER,
    juniAtmSubIfVccPcr               		Integer32,
    juniAtmSubIfVccScr               		Integer32,
    juniAtmSubIfVccMbs               		Integer32,
    juniAtmSubIfInverseArp              	TruthValue,
    juniAtmSubIfInverseArpRefresh       	Integer32,
	juniAtmSubIfVccAssociatedVcClassId  	Unsigned32  }

juniAtmSubIfVccVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VPI of the ATM VCC used by this subinterface."
    ::= { juniAtmSubIfVccEntry 1 }

juniAtmSubIfVccVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VCI of the ATM VCC used by this subinterface."
    ::= { juniAtmSubIfVccEntry 2 }

juniAtmSubIfVccRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy

        To create an entry in this table, the following entry objects MUST be
        explicitly configured:
            juniAtmSubIfVccRowStatus

        In addition, when creating an entry the following conditions must hold:
            The ATM Subinterface identified by juniAtmSubIfIndex must exist.

            A positive value configured for juniAtmSubIfVccVcd must not already
            be assigned to an existing VCC.

            For each value of juniAtmSubIfVccServiceCategory, additional
            dependent objects in the entry require configuration as identified
            here:

            juniAtmSubIfVccServiceCategory    Requires configuration of:
            ------------------------------------------------------------
            ubr                             <none>

            ubrPcr                          juniAtmSubIfVccPcr

            nrtVbr                          juniAtmSubIfVccPcr
                                            juniAtmSubIfVccScr
                                            juniAtmSubIfVccMbs

            cbr                             juniAtmSubIfVccPcr

            rtVbr                           juniAtmSubIfVccPcr
                                            juniAtmSubIfVccScr
                                            juniAtmSubIfVccMbs
            ------------------------------------------------------------

        Attributes in this entry can only be configured at entry creation,
        and remain fixed for the lifetime of the entry."
    ::= { juniAtmSubIfVccEntry 3 }

juniAtmSubIfVccVcd OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "An integer identifier for the circuit, used in conjunction with the
        command-line interface.  It is provided here for cross-reference
        purposes only.

        The value must be unique among VCCs configured on the same underlying
        ATM interface.

        If this object is not configured, or is configured with a value of zero,
        a value will be allocated internally and can be queried after table
        entry creation has succeeded."
    ::= { juniAtmSubIfVccEntry 4 }

juniAtmSubIfVccType OBJECT-TYPE
    SYNTAX      INTEGER {
                    rfc1483VcMux(0),
                    rfc1483Llc(1),
                    autoconfig(2),
                    aal5(3),
                    aal0(4) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Specifies the encapsulation used by the circuit to carry IP datagrams.
        Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
        over ATM.  The 'autoconfig' value will recognize both VcMux and LLC
        formats.  The 'aal5' and 'aal0' values are used for encapsulation 
        methods for transport of ATM frames and cells over IP and MPLS networks
        when no encapsulation method is specified."
    DEFVAL    { rfc1483VcMux }
    ::= { juniAtmSubIfVccEntry 5 }

juniAtmSubIfVccServiceCategory OBJECT-TYPE
    SYNTAX      INTEGER {
                    ubr(0),
                    ubrPcr(1),
                    nrtVbr(2),
                    cbr(3),
                    rtVbr(4) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Service category for this circuit:
            ubr         Unspecified Bit Rate (best effort).
            ubrPcr      Unspecified Bit Rate with Peak Cell Rate limit.
            nrtVbr      Non-RealTime Variable Bit Rate.
            cbr         Constant Bit Rate.
            rtVbr       Realtime Variable Bit Rate."
    DEFVAL    { ubr }
    ::= { juniAtmSubIfVccEntry 6 }

juniAtmSubIfVccPcr OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Peak Cell Rate, in kilobits per second (kbps), of this circuit.

        This parameter is only required when juniAtmSubIfVccServiceCategory is
        configured to have one of the following values:
            ubrPcr
            nrtVbr
            cbr
            rtVbr "
    DEFVAL    { 0 }
    ::= { juniAtmSubIfVccEntry 7 }

juniAtmSubIfVccScr OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Sustained Cell Rate, in kilobits per second (kbps), of this circuit.

        This parameter is only required when juniAtmSubIfVccServiceCategory is
        configured to have the following value:
            nrtVbr
            rtVbr "
    DEFVAL    { 0 }
    ::= { juniAtmSubIfVccEntry 8 }

juniAtmSubIfVccMbs OBJECT-TYPE
    SYNTAX      Integer32 (0..16777215)
    UNITS       "cells"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Maximum Burst Size, in cells, of this circuit.

        This parameter is only required when juniAtmSubIfVccServiceCategory is
        configured to have the following value:
            nrtVbr
            rtVbr "
    DEFVAL    { 0 }
    ::= { juniAtmSubIfVccEntry 9 }

juniAtmSubIfInverseArp OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Enables the inverse ARP protocol on this VCC; true(1) enables the
        protocol, false(2) disables it."
    ::= { juniAtmSubIfVccEntry 10 }

juniAtmSubIfInverseArpRefresh OBJECT-TYPE
    SYNTAX      Integer32 (0..60)
    UNITS       "minutes"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
       "The refresh rate in minutes between inverse ARP protocol messages."
    ::= { juniAtmSubIfVccEntry 11 }

juniAtmSubIfVccAssociatedVcClassId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
		"The integer identifier of the ATM VC class associated with this ATM 
		sub interface. A value for this identifier is determined by locating or 
		creating an ATM VC class name in the juniAtmVcClassNameTable. A value 
		of 0 means no VC class association exists for this VC."
    DEFVAL    { 0 }
    ::= { juniAtmSubIfVccEntry 12 }


--
-- The ATM OAM Table
--
juniAtmCircuitOamTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmCircuitOamEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains circuit OAM data for a PVC."
    ::= { juniAtmSubIfLayer 4 }

juniAtmCircuitOamEntry OBJECT-TYPE
    SYNTAX      JuniAtmCircuitOamEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry provides OAM data on an ATM PVC."
    INDEX     { juniAtmCircuitOamIfIndex,
                juniAtmCircuitOamVpi,
                juniAtmCircuitOamVci }
    ::= { juniAtmCircuitOamTable 1 }

JuniAtmCircuitOamEntry ::= SEQUENCE {
    juniAtmCircuitOamIfIndex                     InterfaceIndex,
    juniAtmCircuitOamVpi                         AtmVpIdentifier,
    juniAtmCircuitOamVci                         AtmVcIdentifier,
    juniAtmCircuitOamAdminStatus                 INTEGER,
    juniAtmCircuitOamLoopbackOperStatus          INTEGER,
    juniAtmCircuitVcOamOperStatus                INTEGER,
    juniAtmCircuitOamLoopbackFrequency           Integer32,
    juniAtmCircuitInOamF5Cells                   Counter32,
    juniAtmCircuitInOamCellsDropped              Counter32,
    juniAtmCircuitOutOamF5Cells                  Counter32,
    juniAtmCircuitInOamF5EndToEndLoopbackCells   Counter32,
    juniAtmCircuitInOamF5SegmentLoopbackCells    Counter32,
    juniAtmCircuitInOamF5AisCells                Counter32,
    juniAtmCircuitInOamF5RdiCells                Counter32,
    juniAtmCircuitOutOamF5EndToEndLoopbackCells  Counter32,
    juniAtmCircuitOutOamF5SegmentLoopbackCells   Counter32,
    juniAtmCircuitOutOamF5RdiCells               Counter32,
    juniAtmCircuitInOamF5EndToEndLoopbackCmds    Counter32,
    juniAtmCircuitInOamF5EndToEndLoopbackRsps    Counter32,
    juniAtmCircuitInOamF5SegmentLoopbackCmds     Counter32,
    juniAtmCircuitInOamF5SegmentLoopbackRsps     Counter32,
    juniAtmCircuitOutOamF5EndToEndLoopbackCmds   Counter32,
    juniAtmCircuitOutOamF5EndToEndLoopbackRsps   Counter32,
    juniAtmCircuitOutOamF5SegmentLoopbackCmds    Counter32,
    juniAtmCircuitOutOamF5SegmentLoopbackRsps    Counter32,
    juniAtmCircuitOamUpCount                     Integer32,
    juniAtmCircuitOamDownCount                   Integer32,
    juniAtmCircuitOamRetryFrequency              Integer32,
    juniAtmCircuitOamAlarmDownCount              Integer32,
    juniAtmCircuitOamAlarmClearTimeout           Integer32 }

juniAtmCircuitOamIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM subinterface."
    ::= { juniAtmCircuitOamEntry 1 }

juniAtmCircuitOamVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VPI of the ATM VCC used by this ATM interface and PVC."
    ::= { juniAtmCircuitOamEntry 2 }

juniAtmCircuitOamVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The VCI of the ATM VCC used by this ATM interface and PVC."
    ::= { juniAtmCircuitOamEntry 3 }

juniAtmCircuitOamAdminStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    oamAdminStateDisabled(1),
                    oamAdminStateEnabled(2) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The administrative state of OAM for the interface identified by this
        entry."
    DEFVAL    { oamAdminStateDisabled }
    ::= { juniAtmCircuitOamEntry 4 }

juniAtmCircuitOamLoopbackOperStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    oamOperStatusNotSupported(0),
                    oamOperStatusDisabled(1),
                    oamOperStatusSent(2),
                    oamOperStatusReceived(3),
                    oamOperStatusFailed(4) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The operational status of OAM for the interface identified by this
        entry.
            oamOperStatusNotSupported(0) - OAM not supported on this interface
            oamOperStatusDisabled(1)     - VC integrity disabled
            oamOperStatusSent(2)         - Loopback sent, awaiting response
            oamOperStatusReceived(3)     - Loopback response received, awaiting
                                           frequency
            oamOperStatusFailed(4)       - Loopback response not received, or
                                           invalid response received"
    ::= { juniAtmCircuitOamEntry 5 }

juniAtmCircuitVcOamOperStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    oamVcOperStateAisState(0),
                    oamVcOperStateRdiState(1),
                    oamVcOperStateDownRetry(2),
                    oamVcOperStateUpRetry(3),
                    oamVcOperStateUp(4),
                    oamVcOperStateDown(5),
                    oamVcOperStateNotManaged(6),
                    oamVcOperStateVpAis(7),
                    oamVcOperStateVpRdi(8),
                    oamVcOperStateVcInVpRdi(9),
                    oamVcoperStateVcInVpAis(10),
                    oamVcOperStateSegAis(11),
                    oamVcOperStateSegRdi(12),
                    oamVcOperStateGenAis(13)}
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The OAM VC operational status of this entry.
            oamVcOperStateAisState(0)  - AIS cell received or underlying
                                         physical layer reporting transmission
                                         path AIS
            oamVcOperStateRdiState(1)  - RDI cell received
            oamVcOperStateDownRetry(2) - OAM loopback failed, using retry
                                         frequency to verify that the VC is
                                         really down
            oamVcOperStateUpRetry(3)   - OAM loopback successful, using retry
                                         frequency to verify that the VC is
                                         really up
            oamVcOperStateUp(4)        - OAM loopback successful after up retry
                                         verification
            oamVcOperStateDown(5)      - OAM loopback failed after down retry
                                         verification
            oamVcOperStateNotManaged(6)- No verification via loopback cells
                                         being performed
            oamVcOperStateVpAis(7)     - F4 AIS cell received
            oamVcOperStateVpRdi(8)     - F4 RDI cell received
            oamVcOperStateVcInVpRdi(9) - F4 RDI cell received; path failure
            oamVcOperStateVcInVpAis(10)- F4 AIS cell received; path failure
            oamVcOperStateSegAis(11)   - Segment AIS cell received
            oamVcOperStateSegRdi(12)   - Segment RDI cell received
            oamVcOperStateGenAis(13)   - Connection failure; generating AIS 
                                         cells."
    ::= { juniAtmCircuitOamEntry 6 }

juniAtmCircuitOamLoopbackFrequency OBJECT-TYPE
    SYNTAX      Integer32 (1..600)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The OAM loopback frequency in seconds."
    DEFVAL    { 10 }
    ::= { juniAtmCircuitOamEntry 7 }

juniAtmCircuitInOamF5Cells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F5 cells."
    ::= { juniAtmCircuitOamEntry 8 }

juniAtmCircuitInOamCellsDropped OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM cells that were dropped."
    ::= { juniAtmCircuitOamEntry 9 }

juniAtmCircuitOutOamF5Cells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F5 cells."
    ::= { juniAtmCircuitOamEntry 10 }

juniAtmCircuitInOamF5EndToEndLoopbackCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total received OAM F5 end-to-end loopback cells. Aggregate of
         juniAtmCircuitInOamF5EndToEndLoopbackCmds and
         juniAtmCircuitInOamF5EndToEndLoopbackRsps"
    ::= { juniAtmCircuitOamEntry 11 }

juniAtmCircuitInOamF5SegmentLoopbackCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total received OAM F5 segment loopback cells. Aggregate of
         juniAtmCircuitInOamF5SegmentLoopbackCmds and
         juniAtmCircuitInOamF5SegmentLoopbackRsps"
    ::= { juniAtmCircuitOamEntry 12 }

juniAtmCircuitInOamF5AisCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F5 AIS cells."
    ::= { juniAtmCircuitOamEntry 13 }

juniAtmCircuitInOamF5RdiCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F5 RDI cells."
    ::= { juniAtmCircuitOamEntry 14 }

juniAtmCircuitOutOamF5EndToEndLoopbackCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total transmitted OAM F5 end-to-end loopback cells. Aggregate of
         juniAtmCircuitOutOamF5EndToEndLoopbackCmds and
         juniAtmCircuitOutOamF5EndToEndLoopbackRsps"
    ::= { juniAtmCircuitOamEntry 15 }

juniAtmCircuitOutOamF5SegmentLoopbackCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total transmitted OAM F5 segment loopback cells. Aggregate of
         juniAtmCircuitOutOamF5SegmentLoopbackCmds and
         juniAtmCircuitOutOamF5SegmentLoopbackRsps"
    ::= { juniAtmCircuitOamEntry 16 }

juniAtmCircuitOutOamF5RdiCells OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F5 RDI cells."
    ::= { juniAtmCircuitOamEntry 17 }

juniAtmCircuitInOamF5EndToEndLoopbackCmds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F5 end-to-end loopback commands."
    ::= { juniAtmCircuitOamEntry 18 }

juniAtmCircuitInOamF5EndToEndLoopbackRsps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F5 end-to-end loopback responses."
    ::= { juniAtmCircuitOamEntry 19 }

juniAtmCircuitInOamF5SegmentLoopbackCmds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F5 segment loopback commands."
    ::= { juniAtmCircuitOamEntry 20 }

juniAtmCircuitInOamF5SegmentLoopbackRsps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received OAM F5 segment loopback responses."
    ::= { juniAtmCircuitOamEntry 21 }

juniAtmCircuitOutOamF5EndToEndLoopbackCmds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F5 end-to-end loopback commands."
    ::= { juniAtmCircuitOamEntry 22 }

juniAtmCircuitOutOamF5EndToEndLoopbackRsps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F5 end-to-end loopback responses."
    ::= { juniAtmCircuitOamEntry 23 }

juniAtmCircuitOutOamF5SegmentLoopbackCmds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F5 segment loopback commands."
    ::= { juniAtmCircuitOamEntry 24 }

juniAtmCircuitOutOamF5SegmentLoopbackRsps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "cells"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted OAM F5 segment loopback responses."
    ::= { juniAtmCircuitOamEntry 25 }

juniAtmCircuitOamUpCount OBJECT-TYPE
    SYNTAX      Integer32 (1..60)
    UNITS       "cells"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Specifies the number of successive loopback cell responses to receive
         before a PVC is up for connectivity verification."
    DEFVAL    { 3 }
    ::= { juniAtmCircuitOamEntry 26 }

juniAtmCircuitOamDownCount OBJECT-TYPE
    SYNTAX      Integer32 (1..60)
    UNITS       "cells"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Specifies the number of successive loopback cell responses not received
         before declaring a PVC down for connectivity verification."
    DEFVAL    { 5 }
    ::= { juniAtmCircuitOamEntry 27 }

juniAtmCircuitOamRetryFrequency OBJECT-TYPE
    SYNTAX      Integer32 (1..600)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Specifies the frequency (in seconds) to transmit loopback cells when
         verifying PVC state (up or down) for connectivity verification."
    DEFVAL    { 1 }
    ::= { juniAtmCircuitOamEntry 28 }

juniAtmCircuitOamAlarmDownCount OBJECT-TYPE
    SYNTAX      Integer32 (1..60)
    UNITS       "cells"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Specifies the number of successive alarm (AIS or RDI) cells to receive
         before declaring a PVC down."
    DEFVAL    { 1 }
    ::= { juniAtmCircuitOamEntry 29 }

juniAtmCircuitOamAlarmClearTimeout OBJECT-TYPE
    SYNTAX      Integer32 (3..60)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Specifies how long to wait (in seconds) before declaring a PVC up after
         it has stopped receiving alarm cells."
    DEFVAL    { 3 }
    ::= { juniAtmCircuitOamEntry 30 }

--
-- The ATM Subinterface VCC Traffic Shaping Table
--
juniAtmSubIfVccTrafficShapingTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmSubIfVccTrafficShapingEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for traffic shaping of ATM VCCs configured
        on ATM subinterfaces present in the system.  This table augments the
        juniAtmSubIfVccTable only for VCCs that support traffic shapping.

        Attributes in this entry can only be configured at entry creation, and
        remain fixed for the lifetime of the entry."
    ::= { juniAtmSubIfLayer 5 }

juniAtmSubIfVccTrafficShapingEntry OBJECT-TYPE
    SYNTAX      JuniAtmSubIfVccTrafficShapingEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the traffic shping characteristics of an ATM
        subinterface VCC."
    AUGMENTS  { juniAtmSubIfVccEntry }
    ::= { juniAtmSubIfVccTrafficShapingTable 1 }

JuniAtmSubIfVccTrafficShapingEntry ::= SEQUENCE {
    juniAtmSubIfVccTrafficShapingCdvt            Unsigned32,
    juniAtmSubIfVccTrafficShapingClp0            TruthValue,
    juniAtmSubIfVccTrafficShapingTagging         TruthValue,
    juniAtmSubIfVccTrafficShapingPoliceObserve   TruthValue,
    juniAtmSubIfVccTrafficShapingPacketShaping   TruthValue }

juniAtmSubIfVccTrafficShapingCdvt OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "tenths of a microsecond"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The network cell delay variation tolerance (CDVT) in tenths of a
        microsecond."
    ::= { juniAtmSubIfVccTrafficShapingEntry 1 }

juniAtmSubIfVccTrafficShapingClp0 OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Specifies whether or not only CLP0 cells are to be policed according to
        the traffic contract.  CLP1 cells are forwarded on a best-effort basis
        CLP-significant model for (VBR.2, VBR.3 conformance).  Applicable only
        for VBR circuits."
    ::= { juniAtmSubIfVccTrafficShapingEntry 2 }

juniAtmSubIfVccTrafficShapingTagging OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Specifies whether or not CLP0 cells should be tagged for SCR policing
        (VBR.3 conformance).  Applicable only for VBR circuits."
    ::= { juniAtmSubIfVccTrafficShapingEntry 3 }

juniAtmSubIfVccTrafficShapingPoliceObserve OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Specifies whether of not no policing action is to be taken (note the
        double negative; if true(1) then no policing action will be taken; if
        false(2) then policing action will be taken).  Regardless of the state
        of this object, all counters will be incremented."
    ::= { juniAtmSubIfVccTrafficShapingEntry 4 }

juniAtmSubIfVccTrafficShapingPacketShaping OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Specifies whether of not to shape output traffic on a packet boundary."
    ::= { juniAtmSubIfVccTrafficShapingEntry 5 }


--
-- The juniAtmSubIfSvcConfigTable for ATM switched
-- virtual connections (SVCs).
--
juniAtmSubIfSvcConfigTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmSubIfSvcConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      deprecated
    DESCRIPTION
        "This table contains entries for extending the juniAtmSubIfTable to
        configure switched virtual connection (SVC) on the subinterfaces."
    ::= { juniAtmSubIfLayer 6 }

juniAtmSubIfSvcConfigEntry OBJECT-TYPE
    SYNTAX      JuniAtmSubIfSvcConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      deprecated
    DESCRIPTION
        "Each entry provides configuration parameters for an ATM SVC on the
        subinterface."
    INDEX     { juniAtmSubIfIndex }
    ::= { juniAtmSubIfSvcConfigTable 1 }

JuniAtmSubIfSvcConfigEntry ::= SEQUENCE {
    juniAtmSubIfSvcRowStatus             RowStatus,
    juniAtmSubIfSvcConfigDestAtmAddress  AtmAddr,
    juniAtmSubIfSvcConfigCircuitType     INTEGER,
    juniAtmSubIfSvcConfigServiceCategory INTEGER,
    juniAtmSubIfSvcConfigPcr             Unsigned32,
    juniAtmSubIfSvcConfigScr             Unsigned32,
    juniAtmSubIfSvcConfigMbs             Unsigned32,
    juniAtmSubIfSvcConfigCdvt            Unsigned32,
    juniAtmSubIfSvcConfigClp0            TruthValue,
    juniAtmSubIfSvcConfigTagging         TruthValue,
    juniAtmSubIfSvcConfigObserve         TruthValue,
    juniAtmSubIfSvcConfigPacketDiscard   TruthValue,
    juniAtmSubIfSvcConfigDestE164Address AtmAddr }

juniAtmSubIfSvcRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy "
    ::= { juniAtmSubIfSvcConfigEntry 1 }

juniAtmSubIfSvcConfigDestAtmAddress OBJECT-TYPE
    SYNTAX      AtmAddr (SIZE(20))
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Specifies the destination ATM NSAP address of the circuit."
    ::= { juniAtmSubIfSvcConfigEntry 2 }

juniAtmSubIfSvcConfigCircuitType OBJECT-TYPE
    SYNTAX      INTEGER {
                    rfc1483VcMux(0),
                    rfc1483Llc(1) }
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Specifies the encapsulation used by the circuit to carry IP datagrams.
        Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
        over ATM."
    DEFVAL    { rfc1483VcMux }
    ::= { juniAtmSubIfSvcConfigEntry 3 }

juniAtmSubIfSvcConfigServiceCategory OBJECT-TYPE
    SYNTAX      INTEGER {
                    ubr(0),
                    ubrPcr(1),
                    nrtVbr(2),
                    cbr(3),
                    rtVbr(4) }
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Service category for this circuit:
            ubr         Unspecified Bit Rate (best effort).
            ubrPcr      Unspecified Bit Rate with Peak Cell Rate limit.
            nrtVbr      Non-RealTime Variable Bit Rate.
            cbr         Constant Bit Rate.
            rtVbr       Realtime Variable Bit Rate."
    DEFVAL    { ubr }
    ::= { juniAtmSubIfSvcConfigEntry 4 }

juniAtmSubIfSvcConfigPcr OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "kbps"
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Peak Cell Rate, in kilo-bits per second (kbps), of this circuit."
    DEFVAL    { 0 }
    ::= { juniAtmSubIfSvcConfigEntry 5 }

juniAtmSubIfSvcConfigScr OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "kbps"
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit."
    DEFVAL    { 0 }
    ::= { juniAtmSubIfSvcConfigEntry 6 }

juniAtmSubIfSvcConfigMbs OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "cells"
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Maximum Burst Size, in cells, of this circuit."
    DEFVAL    { 0 }
    ::= { juniAtmSubIfSvcConfigEntry 7 }

juniAtmSubIfSvcConfigCdvt OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "100us"
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "Specify the network Cell Delay Variation Tolerance."
    ::= { juniAtmSubIfSvcConfigEntry 8 }

juniAtmSubIfSvcConfigClp0 OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Specify that only CLP0 cells are to be policed according to the traffic
        contract.  CLP1 cells are forwarded on a best-effort basis
        CLP-significant model for (VBR.2, VBR.3 conformance)."
    ::= { juniAtmSubIfSvcConfigEntry 9 }

juniAtmSubIfSvcConfigTagging OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Specify that CLP0 cells should be tagged for SCR policing (VBR.3
        conformance)."
    ::= { juniAtmSubIfSvcConfigEntry 10 }

juniAtmSubIfSvcConfigObserve OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "Specify that no policing action is to be taken; only counters are
        incremented."
    ::= { juniAtmSubIfSvcConfigEntry 11 }

juniAtmSubIfSvcConfigPacketDiscard OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      deprecated
    DESCRIPTION
        "Enable early packet Discard  for this circuit."
    ::= { juniAtmSubIfSvcConfigEntry 12 }

juniAtmSubIfSvcConfigDestE164Address OBJECT-TYPE
    SYNTAX      AtmAddr (SIZE(0|8))
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "Specifies the destination ATM E164 address of the circuit."
    ::= { juniAtmSubIfSvcConfigEntry 13 }

--
-- The ATM subinterface description export object
--
juniAtmSubIfDescriptionExport OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Enabling of this object will program the subinterface description down
        to the applicable line card.  Note, the subinterface description sent
        down to the line card is a truncated version (32 bytes) of the ifAlias."
    DEFVAL    { false }
    ::= { juniAtmSubIfLayer 7 }


--
-- The ATM NBMA table
--
juniAtmNbmaMapTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmNbmaMapEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM NBMA maps."
    ::= { juniAtmNbma 1 }

juniAtmNbmaMapEntry OBJECT-TYPE
    SYNTAX      JuniAtmNbmaMapEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics of an ATM NBMA map."
    INDEX     { juniAtmNbmaMapName,
                juniAtmNbmaMapVcd }
    ::= { juniAtmNbmaMapTable 1 }

JuniAtmNbmaMapEntry ::= SEQUENCE {
    juniAtmNbmaMapName       JuniAtmNbmaMapName,
    juniAtmNbmaMapVcd        Integer32,
    juniAtmNbmaMapIpAddress  IpAddress,
    juniAtmNbmaMapVpi        AtmVpIdentifier,
    juniAtmNbmaMapVci        AtmVcIdentifier,
    juniAtmNbmaMapIfIndex    InterfaceIndexOrZero,
    juniAtmNbmaMapBroadcast  TruthValue,
    juniAtmNbmaMapRowStatus  RowStatus }

juniAtmNbmaMapName OBJECT-TYPE
    SYNTAX      JuniAtmNbmaMapName
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The NBMA map name."
    ::= { juniAtmNbmaMapEntry 1 }

juniAtmNbmaMapVcd OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An integer identifier for the ATM circuit, used in conjunction with the
        command-line interface.

        The value must be unique among VCs configured on the same ATM
        interface."
    ::= { juniAtmNbmaMapEntry 2 }

juniAtmNbmaMapIpAddress OBJECT-TYPE
    SYNTAX      IpAddress
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The IP address associated with this entry."
    ::= { juniAtmNbmaMapEntry 3 }

juniAtmNbmaMapVpi OBJECT-TYPE
    SYNTAX      AtmVpIdentifier
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The VPI identifier of the ATM circuit."
    ::= { juniAtmNbmaMapEntry 4 }

juniAtmNbmaMapVci OBJECT-TYPE
    SYNTAX      AtmVcIdentifier
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The VCI identifier of the ATM circuit."
    ::= { juniAtmNbmaMapEntry 5 }

juniAtmNbmaMapIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ifIndex of the ATM major interface associated with this entry.
         The value of this object will be zero when the map is not applied
         to an interface. "
    ::= { juniAtmNbmaMapEntry 6 }

juniAtmNbmaMapBroadcast OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The broadcast enable/disable setting for this entry.  The value true(1)
        enable broadcast support; disable(2) disabled broadcast support for this
        entry."
    ::= { juniAtmNbmaMapEntry 7 }

juniAtmNbmaMapRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy

        Additional notes to aid the network manager:
         - NBMA maps are not supported on dynamic interface.
         - NBMA maps can only be applied to a single major ATM interface at a
           time.
         - NBMA maps cannot be deleted unless the map is removed from the ATM
           interface (juniAtmNbmaMapIfIndex = 0).
         - The values of juniAtmNbmaMapVpi, juniAtmNbmaMapVci and
           juniAtmNbmaMapIfIndex are zero until the map is applied to a major
           ATM interface.
         - To create an entry in this table, the following objects must be
           present in the set PDU:
               juniAtmNbmaMapIpAddress
               juniAtmNbmaMapBroadcast
               juniAtmNbmaMapRowStatus
         - Once created, only the following objects can be modified:
               juniAtmNbmaMapBroadcast "
    ::= { juniAtmNbmaMapEntry 8 }

juniAtmNbmaMapListTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmNbmaMapListEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for ATM NBMA map lists."
    ::= { juniAtmNbma 2 }

juniAtmNbmaMapListEntry OBJECT-TYPE
    SYNTAX      JuniAtmNbmaMapListEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics of an ATM NBMA map."
    INDEX     { IMPLIED juniAtmNbmaMapListName }
    ::= { juniAtmNbmaMapListTable 1 }

JuniAtmNbmaMapListEntry ::= SEQUENCE {
    juniAtmNbmaMapListName       JuniAtmNbmaMapName,
    juniAtmNbmaMapListRowStatus  RowStatus }

juniAtmNbmaMapListName OBJECT-TYPE
    SYNTAX      JuniAtmNbmaMapName
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The NBMA Map List name."
    ::= { juniAtmNbmaMapListEntry 1 }

juniAtmNbmaMapListRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Controls creation/deletion of entries in this table according to the
        RowStatus textual convention, constrained to support the following
        values only:
            createAndGo
            destroy "
    ::= { juniAtmNbmaMapListEntry 2 }


--
-- The ATM ping tests.
--

--
-- ATM ping test types.
--
juniAtmPingTestTypes  OBJECT IDENTIFIER
    ::= { juniAtmPing 1 }

juniAtmPingTestOamSeg  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
        "This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC,
        VCL, or VCC termination point, using segment OAM cells.

        The test type must have appended to it a code that uniquely identifies
        an intermediate point responsible for looping back each cell.  If this
        is absent, the loopbacks are performed at the end of the segment or
        connection.

        E.g., the OID { juniAtmPingTestOamSeg 5 } identifies that the loopbacks
        should be performed at the intermediate point labeled 5."
    ::= { juniAtmPingTestTypes 1 }

juniAtmPingTestOamE2E  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
        "This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC,
        VCL, or VCC termination point, using end-to-end OAM cells."
    ::= { juniAtmPingTestTypes 2 }


--
-- The juniAtmVpPingTable extends the ATM-FORUM-SNMP-M4-MIB.atmM4VpTestTable.
--
juniAtmVpPingTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmVpPingEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB
        atmM4VpTestTable to do ping (multiple loopback) type testing."
    ::= { juniAtmPing 2 }

juniAtmVpPingEntry OBJECT-TYPE
    SYNTAX      JuniAtmVpPingEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics, status and results of the
        most recent ATM ping test."
    INDEX     { ifIndex,
                atmVplVpi,
                atmfM4VpTestObject }
    ::= { juniAtmVpPingTable 1 }

JuniAtmVpPingEntry ::= SEQUENCE {
    juniAtmVpPingProbeCount          Unsigned32,
    juniAtmVpPingTimeOut             Unsigned32,
    juniAtmVpPingCtlTrapGeneration   BITS,
    juniAtmVpPingSentProbes          Unsigned32,
    juniAtmVpPingProbeResponses      Unsigned32,
    juniAtmVpPingStartTime           TimeStamp,
    juniAtmVpPingMinRtt              Unsigned32,
    juniAtmVpPingMaxRtt              Unsigned32,
    juniAtmVpPingAverageRtt          Unsigned32 }

juniAtmVpPingProbeCount OBJECT-TYPE
    SYNTAX      Unsigned32 (1..32)
    UNITS       "probes"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The number of ping probes (OAM cells) to be sent to complete the test."
    DEFVAL    { 5 }
    ::= { juniAtmVpPingEntry 1 }

juniAtmVpPingTimeOut OBJECT-TYPE
    SYNTAX      Unsigned32 (1..5)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Specifies the time-out value, in seconds, for a remote ping operation."
    DEFVAL    { 5 }
    ::= { juniAtmVpPingEntry 2 }

juniAtmVpPingCtlTrapGeneration OBJECT-TYPE
    SYNTAX      BITS {
                    testCompletion(0) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of this object determines when and if to generate a
        notification for this entry:

        testCompletion(0) - Generate a juniPingTestCompleted notification.

        The value of this object defaults to zero, indicating that no
        notification has been selected."
    DEFVAL    { { } }
    ::= { juniAtmVpPingEntry 3 }

juniAtmVpPingSentProbes OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "probes"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of ping probes (OAM cells) that have been sent thus far for
        this test.  The value of this object MUST be set to zero when the
        atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1)."
    DEFVAL    { 0 }
    ::= { juniAtmVpPingEntry 4 }

juniAtmVpPingProbeResponses OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "probes"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of ping responses that have been received thus far for this
        test.  The value of this object MUST be set to zero when the
        atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1)."
    DEFVAL    { 0 }
    ::= { juniAtmVpPingEntry 5 }

juniAtmVpPingStartTime OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time (sysUpTime) when the test started."
    DEFVAL    { 0 }
    ::= { juniAtmVpPingEntry 6 }

juniAtmVpPingMinRtt OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliseconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The shortest round-trip-time (RTT) for the pings that have received
        responses.  The value of this object MUST be set to zero when the
        atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).  A
        value of zero for this object implies that no ping responses have been
        received for the current test."
    ::= { juniAtmVpPingEntry 7 }

juniAtmVpPingMaxRtt OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliseconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The longest round-trip-time (RTT) for the pings that have received
        responses.  The value of this object MUST be set to zero when the
        atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).  A
        value of zero for this object implies that no ping responses have been
        received for the current test."
    ::= { juniAtmVpPingEntry 8 }

juniAtmVpPingAverageRtt OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliseconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The average round-trip-time (RTT) for all the pings that have received
        responses.  The value of this object MUST be set to zero when the
        atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).  A
        value of zero for this object implies that no ping responses have been
        received for the current test."
    ::= { juniAtmVpPingEntry 9 }


--
-- The juniAtmVcPingTable extends the ATM-FORUM-SNMP-M4-MIB.atmM4VcTestTable.
--
juniAtmVcPingTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmVcPingEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB
        atmM4VcTestTable to do ping (multiple loopback) type testing."
    ::= { juniAtmPing 3 }

juniAtmVcPingEntry OBJECT-TYPE
    SYNTAX      JuniAtmVcPingEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry describes the characteristics, status and results of the
        most recent ATM ping test."
    INDEX     { ifIndex,
                atmVclVpi,
                atmVclVci,
                atmfM4VcTestObject }
    ::= { juniAtmVcPingTable 1 }

JuniAtmVcPingEntry ::= SEQUENCE {
    juniAtmVcPingProbeCount          Unsigned32,
    juniAtmVcPingTimeOut             Unsigned32,
    juniAtmVcPingCtlTrapGeneration   BITS,
    juniAtmVcPingSentProbes          Unsigned32,
    juniAtmVcPingProbeResponses      Unsigned32,
    juniAtmVcPingStartTime           TimeStamp,
    juniAtmVcPingMinRtt              Unsigned32,
    juniAtmVcPingMaxRtt              Unsigned32,
    juniAtmVcPingAverageRtt          Unsigned32 }

juniAtmVcPingProbeCount OBJECT-TYPE
    SYNTAX      Unsigned32 (1..32)
    UNITS       "probes"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The number of ping probes (OAM cells) to be sent to complete the test."
    DEFVAL    { 5 }
    ::= { juniAtmVcPingEntry 1 }

juniAtmVcPingTimeOut OBJECT-TYPE
    SYNTAX      Unsigned32 (1..5)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Specifies the time-out value, in seconds, for a remote ping operation."
    DEFVAL    { 5 }
    ::= { juniAtmVcPingEntry 2 }

juniAtmVcPingCtlTrapGeneration OBJECT-TYPE
    SYNTAX      BITS {
                    testCompletion(0) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of this object determines when and if to generate a
        notification for this entry:
            testCompletion(0) - Generate a juniPingTestCompleted notification.

        The value of this object defaults to zero, indicating that no
        notification has been selected."
    DEFVAL    { { } }
    ::= { juniAtmVcPingEntry 3 }

juniAtmVcPingSentProbes OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "probes"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of ping probes (OAM cells) that have been sent thus far for
        this test.  The value of this object MUST be set to zero when the
        atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1)."
    DEFVAL    { 0 }
    ::= { juniAtmVcPingEntry 4 }

juniAtmVcPingProbeResponses OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "probes"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of ping responses that have been received thus far for this
        test.  The value of this object MUST be set to zero when the
        atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1)."
    DEFVAL    { 0 }
    ::= { juniAtmVcPingEntry 5 }

juniAtmVcPingStartTime OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time (sysUpTime) when the test started."
    DEFVAL    { 0 }
    ::= { juniAtmVcPingEntry 6 }

juniAtmVcPingMinRtt OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliseconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The shortest round-trip-time (RTT) for the pings that have received
        responses.  The value of this object MUST be set to zero when the
        atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).  A
        value of zero for this object implies that no ping responses have been
        received for the current test."
    ::= { juniAtmVcPingEntry 7 }

juniAtmVcPingMaxRtt OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliseconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The longest round-trip-time (RTT) for the pings that have received
        responses.  The value of this object MUST be set to zero when the
        atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).  A
        value of zero for this object implies that no ping responses have been
        received for the current test."
    ::= { juniAtmVcPingEntry 8 }

juniAtmVcPingAverageRtt OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliseconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The average round-trip-time (RTT) for all the pings that have received
        responses.  The value of this object MUST be set to zero when the
        atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).  A
        value of zero for this object implies that no ping responses have been
        received for the current test."
    ::= { juniAtmVcPingEntry 9 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- ATM ping test codes.
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniAtmPingTestCode  OBJECT IDENTIFIER ::= { juniAtmPing 4 }

juniAtmPingTestCodeOamDisabled  OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "This test code indicates that the ATM ping operation cannot be
        initiated or is aborted because the juniAtmIfOamCellRxAdminState is set
        to disabled."
    ::= { juniAtmPingTestCode 1 }

juniAtmPingTestCodeCircuitDown  OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "This test code indicates that the ATM ping operation cannot be
        initiated or is aborted because the operational status of the ATM
        circuit is down."
    ::= { juniAtmPingTestCode 2 }

juniAtmPingTestCodeStopped  OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "This test code indicates that the ATM ping operation is
        administratively stopped by an External Management."
    ::= { juniAtmPingTestCode 3 }

juniAtmPingTestCodeOamVcOperState  OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "This test code indicates that the ATM ping operation cannot be
        initiated or is aborted because the circuit is down because of a OAM
        fault condition.  This is possible if juniAtmCircuitVcOamOperStatus is
        one of the following:
            oamVcOperStateAisState(0)  - AIS cell received or underlying
                                         physical layer reporting transmission
                                         path AIS.
            oamVcOperStateRdiState(1)  - RDI cell received."
    ::= { juniAtmPingTestCode 4 }

juniAtmPingTestCodeMaxPingCountReached  OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "This test code indicates that the ping operation cannot be initiated as
        the maximum number of ping possible on this interfaces exceeds the
        allowable limit."
    ::= { juniAtmPingTestCode 5 }

juniAtmPingTestCodeInvalidParams  OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "This Test Code identities the Ping operation cannot be initiated as one
        or more of the Ping Parameters is Invalid."
    ::= { juniAtmPingTestCode 6 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- ATM Subinterface information by interface location
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniAtmSubIfLocationType OBJECT-TYPE
    SYNTAX      JuniInterfaceLocationType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Describes the interpretation of JuniInterfaceLocationValue object
        values into platform-dependent interface location components, e.g.,
        'slot.port' on an ERX."
    ::= { juniAtmLocation 1 }

juniAtmSubIfLocationTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmSubIfLocationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The entries in this table report the ifIndex of ATM Subinterfaces by
        location."
    ::= { juniAtmLocation 2 }

juniAtmSubIfLocationEntry OBJECT-TYPE
    SYNTAX      JuniAtmSubIfLocationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A specification of ATM subinterfaces by location."
    INDEX     { juniAtmSubIfLocationIndex,
                juniAtmSubIfDistinguisher }
    ::= { juniAtmSubIfLocationTable 1 }

JuniAtmSubIfLocationEntry ::= SEQUENCE {
    juniAtmSubIfLocationIndex       JuniInterfaceLocationValue,
    juniAtmSubIfLocationIfIndex     InterfaceIndex }

juniAtmSubIfLocationIndex OBJECT-TYPE
    SYNTAX      JuniInterfaceLocationValue
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of a platform interface location."
    ::= { juniAtmSubIfLocationEntry 1 }

juniAtmSubIfLocationIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ifIndex value of this subinterface."
    ::= { juniAtmSubIfLocationEntry 2 }


juniAtmVcClassNameTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmVcClassNameEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
		"The entries in this table provide mappings of ATM VC class names to 
		local integer identifiers. These integers are used as indexes into other 
		MIB tables containing ATM VC attributes associated with the same VC class name."
    ::= { juniAtmVcClass 1 }

juniAtmVcClassNameEntry OBJECT-TYPE
    SYNTAX      JuniAtmVcClassNameEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
		"A mapping of ATM VC class name to an integer identifier for the ATM VC class."
    INDEX     { IMPLIED juniAtmVcClassName }
    ::= { juniAtmVcClassNameTable 1 }

JuniAtmVcClassNameEntry ::= SEQUENCE {
    juniAtmVcClassName               DisplayString,
    juniAtmVcClassNameRowStatus      RowStatus,
    juniAtmVcClassNameId             Unsigned32 }

juniAtmVcClassName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(1..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ATM VC class name uniquely identifying this entry."
    ::= { juniAtmVcClassNameEntry 1 }

juniAtmVcClassNameRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
		"Controls creation/deletion of entries in this table.  Only the values 
		'createAndGo' ,'destroy', 'active' and 'notInService' may be SET. 
		The SNMP manager would set the row status to notInService before making 
		any VC class attribute changes explained in juniAtmVcClassTable. Once the 
		VC class attribute changes are complete, the SNMP manager would set the 
		row status to active, upon which the VC class attribute changes would 
		be committed. Any ATM VC class attribute changes that are made when the 
		row status is 'active' are committed right away."
    ::= { juniAtmVcClassNameEntry 2 }

juniAtmVcClassNameId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
		"The integer identifier associated with this VC class name. The value of 
		this identifier is assigned by the device when an entry in this table 
		is created."
    ::= { juniAtmVcClassNameEntry 3 }

juniAtmVcClassIdTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmVcClassIdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
		"Provides inverse mapping of ATM VC class IDs to ATM VC class names."
    ::= { juniAtmVcClass 2 }

juniAtmVcClassIdEntry OBJECT-TYPE
    SYNTAX      JuniAtmVcClassIdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
		"A mapping of an integer identifier to an ATM VC class name."
    INDEX     { juniAtmVcClassIdId }
    ::= { juniAtmVcClassIdTable 1 }

JuniAtmVcClassIdEntry ::= SEQUENCE {
    juniAtmVcClassIdId                  Unsigned32,
    juniAtmVcClassIdName                DisplayString }

juniAtmVcClassIdId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
		"The integer identifier associated with this ATM VC class name."
    ::= { juniAtmVcClassIdEntry 1 }

juniAtmVcClassIdName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(1..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
		"The ATM VC class name having the associated identifier."
    ::= { juniAtmVcClassIdEntry 2 }

--
--ATM VC class table
--
juniAtmVcClassTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF JuniAtmVcClassEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
		"This table contains Juniper ATM VC Class entries which can be used 
		to specify the ATM PVC attributes either at creation or modification 
		time. A row in this table with default values is created when an entry 
		in juniAtmVcClassNameTable is created."
    ::= { juniAtmVcClass 3 }
juniAtmVcClassEntry OBJECT-TYPE
    SYNTAX      JuniAtmVcClassEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
		"Each entry contains the attributes of the ATM VC which would be 
		applied to the VC either at creation or modification time when this 
		ATM VC class is associated to it."
    INDEX     { juniAtmVcClassId }
             
    ::= { juniAtmVcClassTable 1 }


JuniAtmVcClassEntry ::= SEQUENCE {
	juniAtmVcClassId 							Unsigned32,
	juniAtmVcClassVccType 					INTEGER,
	juniAtmVcClassVccServiceCategory			INTEGER,
	juniAtmVcClassVccPcr						Integer32,
	juniAtmVcClassVccScr						Integer32,
	juniAtmVcClassVccMbs						Integer32,
	juniAtmVcClassVccOamAdminStatus			INTEGER,
	juniAtmVcClassVccOamLoopbackFrequency		Integer32,
	juniAtmVcClassVccOamUpCount				Integer32,
	juniAtmVcClassVccOamDownCount				Integer32,
	juniAtmVcClassVccOamRetryFrequency		Integer32,
	juniAtmVcClassVccOamAlarmDownCount		Integer32,
	juniAtmVcClassVccOamAlarmClearTimeout		Integer32,
	juniAtmVcClassVccInverseArp				TruthValue,
	juniAtmVcClassVccInverseArpRefresh		Integer32 }

juniAtmVcClassId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
		"The integer identifier associated with this ATM VC class.  A value 
		for this identifier is determined by locating or creating an ATM VC 
		class name in the juniAtmVcClassNameTable."
    ::= { juniAtmVcClassEntry 1 }
     
juniAtmVcClassVccType OBJECT-TYPE
    SYNTAX      INTEGER {
                    rfc1483VcMux(0),
                    rfc1483Llc(1),
                    autoconfig(2),
                    aal5(3),
                    aal0(4) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"Specifies the encapsulation used by the circuit to carry IP datagrams. 
		Encapsulations are as specified in RFC1483 Multiprotocol Interconnect 
		over ATM. The 'autoconfig' value will recognize both VC Mux and LLC 
		formats. The 'aal5' and 'aal0' values are used for encapsulation 
		methods for transport of ATM frames and cells over IP and MPLS networks 
		when no encapsulation method is specified."
    DEFVAL    { rfc1483VcMux }

    ::= { juniAtmVcClassEntry 2 }

juniAtmVcClassVccServiceCategory OBJECT-TYPE
    SYNTAX      INTEGER {
                    ubr(0),
                    ubrPcr(1),
                    nrtVbr(2),
                    cbr(3),
                    rtVbr(4) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Service category for this circuit:
            ubr         Unspecified Bit Rate (best effort).
            ubrPcr      Unspecified Bit Rate with Peak Cell Rate limit.
            nrtVbr      Non-RealTime Variable Bit Rate.
            cbr         Constant Bit Rate.
            rtVbr       Realtime Variable Bit Rate."
    DEFVAL    { ubr }
    ::= { juniAtmVcClassEntry 3 }

juniAtmVcClassVccPcr OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Peak Cell Rate, in kilobits per second (kbps), of this circuit.

        This parameter is only required when juniAtmVcClassVccServiceCategory is
        configured to have one of the following values:
            ubrPcr
            nrtVbr
            cbr
            rtVbr "
    DEFVAL    { 0 }
    ::= { juniAtmVcClassEntry 4 }

juniAtmVcClassVccScr OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    UNITS       "kbps"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"Sustained Cell Rate, in kilobits per second (kbps), of this circuit.
		This parameter is only required when juniAtmVcClassVccServiceCategory 
		is configured to have the following value:
            nrtVbr
            rtVbr "
    DEFVAL    { 0 }
    ::= { juniAtmVcClassEntry 5 }


juniAtmVcClassVccMbs OBJECT-TYPE
    SYNTAX      Integer32 (0..16777215)
    UNITS       "cells"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"Maximum Burst Size, in cells, of this circuit.
		This parameter is only required when juniAtmVcClassVccServiceCategory 
		is configured to have the following value:
		nrtVbr
		rtVbr "
    DEFVAL    { 0 }
    ::= { juniAtmVcClassEntry 6 }

juniAtmVcClassVccOamAdminStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    oamAdminStateDisabled(1),
                    oamAdminStateEnabled(2) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"The OAM VC integrity administrative state of the ATM VC associated 
		with this class."
    DEFVAL    { oamAdminStateDisabled }
    ::= { juniAtmVcClassEntry 7 }

juniAtmVcClassVccOamLoopbackFrequency OBJECT-TYPE
    SYNTAX      Integer32 (1..600)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The OAM loopback frequency in seconds."
    DEFVAL    { 10 }
    ::= { juniAtmVcClassEntry 8 }

juniAtmVcClassVccOamUpCount OBJECT-TYPE
    SYNTAX      Integer32 (1..60)
    UNITS       "cells"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"Specifies the number of successive loopback cell responses to 
		receive before the ATM VC associated with this class is declared 
		up for connectivity verification."
    DEFVAL    { 3 }
    ::= { juniAtmVcClassEntry 9 }

juniAtmVcClassVccOamDownCount OBJECT-TYPE
    SYNTAX      Integer32 (1..60)
    UNITS       "cells"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"Specifies the number of successive loopback cell responses not 
		received before declaring the ATM VC associated with this class 
		as down for connectivity verification."
    DEFVAL    { 5 }
    ::= { juniAtmVcClassEntry 10 }

juniAtmVcClassVccOamRetryFrequency OBJECT-TYPE
    SYNTAX      Integer32 (1..600)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"Specifies the frequency (in seconds) to transmit loopback cells 
		when verifying the ATM VC operational state associated with this 
		class (up or down) for connectivity verification."
    DEFVAL    { 1 }
    ::= { juniAtmVcClassEntry 11 }

juniAtmVcClassVccOamAlarmDownCount OBJECT-TYPE
    SYNTAX      Integer32 (1..60)
    UNITS       "cells"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"Specifies the number of successive alarm (AIS or RDI) cells to 
		receive before declaring the ATM VC associated with class as down."
    DEFVAL    { 1 }
    ::= { juniAtmVcClassEntry 12 }

juniAtmVcClassVccOamAlarmClearTimeout OBJECT-TYPE
    SYNTAX      Integer32 (3..60)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
	DESCRIPTION
		"Specifies how long to wait (in seconds) before declaring the ATM VC 
		associated with class as up after it has stopped receiving alarm cells."
    DEFVAL    { 3 }
    ::= { juniAtmVcClassEntry 13 }


juniAtmVcClassVccInverseArp OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"Enables the inverse ARP protocol on the ATM VC associated with this 
		class; true(1) enables the protocol, false(2) disables it."
    ::= { juniAtmVcClassEntry 14 }

juniAtmVcClassVccInverseArpRefresh OBJECT-TYPE
    SYNTAX      Integer32 (0..60)
    UNITS       "minutes"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
		"The refresh rate in minutes between inverse ARP protocol messages."
    ::= { juniAtmVcClassEntry 15 }



-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notification control objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- No global notification controls are defined.  Placeholder follows.
-- juniAtmTrapControl      OBJECT IDENTIFIER ::= { juniAtmMIB 2 }

-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notifications
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- The following two OBJECT IDENTIFIERS are used to define SNMPv2
-- Notifications that are easily translated into SNMPv1 Traps.

juniAtmTraps            OBJECT IDENTIFIER ::= { juniAtmMIB 3 }
juniAtmTrapPrefix       OBJECT IDENTIFIER ::= { juniAtmTraps 0 }

juniAtmVpPingTestCompleted NOTIFICATION-TYPE
    OBJECTS {
        atmfM4VpTestId,
        atmfM4VpTestType,
        atmfM4VpTestResult,
        juniAtmVpPingProbeCount,
        juniAtmVpPingSentProbes,
        juniAtmVpPingProbeResponses,
        juniAtmVpPingMinRtt,
        juniAtmVpPingMaxRtt,
        juniAtmVpPingAverageRtt,
        atmfM4VpTestCode }
    STATUS      current
    DESCRIPTION
        "Generated at the completion of a AtmfM4VpTest when the corresponding
        juniAtmVpPingCtlTrapGeneration object has the testCompletion(0) bit
        set."
    ::= { juniAtmTrapPrefix 1 }

juniAtmVcPingTestCompleted NOTIFICATION-TYPE
    OBJECTS {
        atmfM4VcTestId,
        atmfM4VcTestType,
        atmfM4VcTestResult,
        juniAtmVcPingProbeCount,
        juniAtmVcPingSentProbes,
        juniAtmVcPingProbeResponses,
        juniAtmVcPingMinRtt,
        juniAtmVcPingMaxRtt,
        juniAtmVcPingAverageRtt,
        atmfM4VcTestCode }
    STATUS      current
    DESCRIPTION
        "Generated at the completion of a AtmfM4VcTest when the corresponding
        juniAtmVcPingCtlTrapGeneration object has the testCompletion(0) bit
        set."
    ::= { juniAtmTrapPrefix 2 }


-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniAtmConformance OBJECT IDENTIFIER ::= { juniAtmMIB 4 }
juniAtmCompliances OBJECT IDENTIFIER ::= { juniAtmConformance 1 }
juniAtmGroups      OBJECT IDENTIFIER ::= { juniAtmConformance 2 }

--
-- compliance statements
--
juniAtmCompliance  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when support was added for NBMA
        map lists and ATM ping."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup,
            juniAtmAal5Group,
            juniAtmSubIfGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
    ::= { juniAtmCompliances 1 }                                   -- JUNOSe 3.0

juniAtmCompliance2  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when support was added for
        traffic shapping on VCC subinterfaces."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup2,
            juniAtmAal5Group,
            juniAtmSubIfGroup2,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
    ::= { juniAtmCompliances 2 }                                   -- JUNOSe 3.2

juniAtmCompliance3  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when support was added for
        connection admission control (CAC)."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup2,
            juniAtmAal5Group,
            juniAtmSubIfGroup2,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
    ::= { juniAtmCompliances 3 }                                   -- JUNOSe 3.3

juniAtmCompliance4  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when ATM SVC, CAC used
        bandwidth and sub-interface address objects were added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup3,
            juniAtmAal5Group,
            juniAtmSubIfGroup2,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
    ::= { juniAtmCompliances 4 }                                   -- JUNOSe 3.4

juniAtmCompliance5  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when CAC recieve bandwith and
        E164 public addressing support was added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup4,
            juniAtmAal5Group,
            juniAtmSubIfGroup3,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
    ::= { juniAtmCompliances 5 }                                   -- JUNOSe 4.0

juniAtmCompliance6  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when F4 flow OAM circuit config
        and stats tables were added to the Juniper ATM MIB."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup5,
            juniAtmAal5Group,
            juniAtmSubIfGroup4,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2 }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
    ::= { juniAtmCompliances 6 }                                   -- JUNOSe 4.1

juniAtmCompliance7  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when the juniAtmLocationGroup
        was added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup6,
            juniAtmAal5Group,
            juniAtmSubIfGroup4,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2,
            juniAtmF4OamCircuitGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
    ::= { juniAtmCompliances 7 }                                   -- JUNOSe 5.1

juniAtmCompliance8  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when support was added to
        export the subinterface description to the line cards."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup6,
            juniAtmAal5Group,
            juniAtmSubIfGroup4,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2,
            juniAtmF4OamCircuitGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
        GROUP       juniAtmLocationGroup
            DESCRIPTION
                "The juniAtmLocationGroup is mandatory only for entities that
                support slot and port interface location information"
    ::= { juniAtmCompliances 8 }                                   -- JUNOSe 5.2

juniAtmCompliance9  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement was obsoleted when the juniAtmMartiniGroup was
        added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup6,
            juniAtmAal5Group,
            juniAtmSubIfGroup5,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2,
            juniAtmF4OamCircuitGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
        GROUP       juniAtmLocationGroup
            DESCRIPTION
                "The juniAtmLocationGroup is mandatory only for entities that
                support slot and port interface location information"
    ::= { juniAtmCompliances 9 }                                   -- JUNOSe 5.3

juniAtmCompliance10  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when 
        juniAtmIfCacAvailableBandwidthRx, juniAtmIfE164Autoconversion, 
        juniAtmIfE164Gateway, and juniAtmIfE164OneToOneAddrTrans were 
        deprecated."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup6,
            juniAtmAal5Group,
            juniAtmSubIfGroup5,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2,
            juniAtmF4OamCircuitGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
        GROUP       juniAtmLocationGroup
            DESCRIPTION
                "The juniAtmLocationGroup is mandatory only for entities that
                support slot and port interface location information"
        GROUP       juniAtmMartiniGroup
            DESCRIPTION
                "The juniAtmMartiniGroup is mandatory only for entities that
                support ATM Martini cell aggregation configuration"
    ::= { juniAtmCompliances 10 }                                  -- JUNOSe 6.0

juniAtmCompliance11  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "Obsolete compliance statement for entities which implement the Juniper
        ATM MIB.  This statement became obsolete when juniAtmGroup8 was 
        added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup7,
            juniAtmAal5Group,
            juniAtmSubIfGroup5,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2,
            juniAtmF4OamCircuitGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
        GROUP       juniAtmLocationGroup
            DESCRIPTION
                "The juniAtmLocationGroup is mandatory only for entities that
                support slot and port interface location information"
        GROUP       juniAtmMartiniGroup
            DESCRIPTION
                "The juniAtmMartiniGroup is mandatory only for entities that
                support ATM Martini cell aggregation configuration"
    ::= { juniAtmCompliances 11 }                                 -- JUNOSe 6.1

juniAtmCompliance12  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for entities which implement the Juniper ATM
        MIB. This statement became obsolete when juniAtmVpStatsGroup was added."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup8,
            juniAtmAal5Group,
            juniAtmSubIfGroup5,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2,
            juniAtmF4OamCircuitGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
        GROUP       juniAtmLocationGroup
            DESCRIPTION
                "The juniAtmLocationGroup is mandatory only for entities that
                support slot and port interface location information"
        GROUP       juniAtmMartiniGroup
            DESCRIPTION
                "The juniAtmMartiniGroup is mandatory only for entities that
                support ATM Martini cell aggregation configuration"
    ::= { juniAtmCompliances 12 }                                  -- JUNOSe 7.0

juniAtmCompliance13  MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for entities which implement the Juniper ATM
        MIB.  This statement became obsolete when SVC support was removed."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup8,
            juniAtmAal5Group,
            juniAtmSubIfGroup6,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2,
            juniAtmF4OamCircuitGroup2,
            juniAtmVpStatsGroup }
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
        GROUP       juniAtmLocationGroup
            DESCRIPTION
                "The juniAtmLocationGroup is mandatory only for entities that
                support slot and port interface location information"
        GROUP       juniAtmMartiniGroup
            DESCRIPTION
                "The juniAtmMartiniGroup is mandatory only for entities that
                support ATM Martini cell aggregation configuration"
    ::= { juniAtmCompliances 13 }                                  -- JUNOSe 7.1

juniAtmCompliance14  MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for entities which implement the Juniper ATM
        MIB."
    MODULE   -- this module
        MANDATORY-GROUPS {
            juniAtmGroup9,
            juniAtmAal5Group,
            juniAtmSubIfGroup7,
            juniAtmVpPingControlGroup,
            juniAtmVcPingControlGroup,
            juniAtmPingTrapGroup,
            juniAtmSvcGroup2,
            juniAtmF4OamCircuitGroup2,
			juniAtmVpStatsGroup,
			juniAtmVcClassGroup}
        GROUP       juniAtmVpTunnelGroup
            DESCRIPTION
                "The juniAtmVpTunnelGroup is mandatory only for entities that
                support a VP Tunnel functionality."
        GROUP       juniAtmNbmaMapGroup
            DESCRIPTION
                "The juniAtmNbmaMapGroup is mandatory only for entities that
                support NBMA interfaces over ATM."
        GROUP       juniAtmTrafficShapingGroup
            DESCRIPTION
                "The juniAtmTrafficShapingGroup is mandatory only for entities
                that support ATM traffic shaping."
        GROUP       juniAtmPnniGroup
            DESCRIPTION
                "The juniAtmPnniGroup is mandatory only for entities that
                support PNNI routing for ATM networks."
        GROUP       juniAtmLocationGroup
            DESCRIPTION
                "The juniAtmLocationGroup is mandatory only for entities that
                support slot and port interface location information"
        GROUP       juniAtmMartiniGroup
            DESCRIPTION
                "The juniAtmMartiniGroup is mandatory only for entities that
                support ATM Martini cell aggregation configuration"
		GROUP  		juniAtmVcClassGroup
			DESCRIPTION
				"The juniAtmVcClassGroup is mandatory only for entities that
                support ATM VC class configuration"
    ::= { juniAtmCompliances 14 }                                  -- JUNOSe 7.3


--
-- units of conformance
--
juniAtmGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,

        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM interfaces
        in a Juniper product.  This group became obsolete when the
        juniAtmIfMapGroup object was added."
    ::= { juniAtmGroups 1 }                                        -- JUNOSe 3.0

juniAtmAal5Group  OBJECT-GROUP
    OBJECTS {
        juniAtmAal5NextIfIndex,

        juniAtmAal5IfRowStatus,
        juniAtmAal5IfLowerIfIndex }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing management of AAL5 interfaces in a
        Juniper product."
    ::= { juniAtmGroups 2 }                                        -- JUNOSe 3.0

juniAtmSubIfGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfNextIfIndex,

        juniAtmSubIfRowStatus,
        juniAtmSubIfDistinguisher,
        juniAtmSubIfLowerIfIndex,

        juniAtmSubIfVccRowStatus,
        juniAtmSubIfVccVcd,
        juniAtmSubIfVccType,
        juniAtmSubIfVccServiceCategory,
        juniAtmSubIfVccPcr,
        juniAtmSubIfVccScr,
        juniAtmSubIfVccMbs,

        juniAtmCircuitOamAdminStatus,
        juniAtmCircuitOamLoopbackOperStatus,
        juniAtmCircuitVcOamOperStatus,
        juniAtmCircuitOamLoopbackFrequency,
        juniAtmCircuitInOamF5Cells,
        juniAtmCircuitInOamCellsDropped,
        juniAtmCircuitOutOamF5Cells,
        juniAtmCircuitInOamF5EndToEndLoopbackCells,
        juniAtmCircuitInOamF5SegmentLoopbackCells,
        juniAtmCircuitInOamF5AisCells,
        juniAtmCircuitInOamF5RdiCells,
        juniAtmCircuitOutOamF5EndToEndLoopbackCells,
        juniAtmCircuitOutOamF5SegmentLoopbackCells,
        juniAtmCircuitOutOamF5RdiCells }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM
        subinterfaces in a Juniper product.  This group became obsolete when
        juniAtmSubIfNbma, juniAtmSubIfInverseArp, and
        juniAtmSubIfInverseArpRefresh were added."
    ::= { juniAtmGroups 3 }                                        -- JUNOSe 3.0

juniAtmVpTunnelGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmVpTunnelKbps,
        juniAtmVpTunnelRowStatus,
        juniAtmVpTunnelServiceCategory }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing management of VP tunnels in a Juniper
        product."
    ::= { juniAtmGroups 4 }                                        -- JUNOSe 3.0

juniAtmNbmaMapGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmNbmaMapIpAddress,
        juniAtmNbmaMapVpi,
        juniAtmNbmaMapVci,
        juniAtmNbmaMapIfIndex,
        juniAtmNbmaMapBroadcast,
        juniAtmNbmaMapRowStatus,
        juniAtmNbmaMapListRowStatus }
    STATUS      current
    DESCRIPTION
        "A collection of object providing management of NBMA in a Juniper
        product."
    ::= { juniAtmGroups 5 }                                        -- JUNOSe 3.2

juniAtmSubIfGroup2  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfNextIfIndex,

        juniAtmSubIfRowStatus,
        juniAtmSubIfDistinguisher,
        juniAtmSubIfLowerIfIndex,
        juniAtmSubIfNbma,

        juniAtmSubIfVccRowStatus,
        juniAtmSubIfVccVcd,
        juniAtmSubIfVccType,
        juniAtmSubIfVccServiceCategory,
        juniAtmSubIfVccPcr,
        juniAtmSubIfVccScr,
        juniAtmSubIfVccMbs,
        juniAtmSubIfInverseArp,
        juniAtmSubIfInverseArpRefresh,

        juniAtmCircuitOamAdminStatus,
        juniAtmCircuitOamLoopbackOperStatus,
        juniAtmCircuitVcOamOperStatus,
        juniAtmCircuitOamLoopbackFrequency,
        juniAtmCircuitInOamF5Cells,
        juniAtmCircuitInOamCellsDropped,
        juniAtmCircuitOutOamF5Cells,
        juniAtmCircuitInOamF5EndToEndLoopbackCells,
        juniAtmCircuitInOamF5SegmentLoopbackCells,
        juniAtmCircuitInOamF5AisCells,
        juniAtmCircuitInOamF5RdiCells,
        juniAtmCircuitOutOamF5EndToEndLoopbackCells,
        juniAtmCircuitOutOamF5SegmentLoopbackCells,
        juniAtmCircuitOutOamF5RdiCells }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM
        subinterfaces in a Juniper product.  This group became obsolete when
        juniAtmSubIfAddress was added."
    ::= { juniAtmGroups 6 }                                        -- JUNOSe 3.2

juniAtmVpPingControlGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmVpPingProbeCount,
        juniAtmVpPingTimeOut,
        juniAtmVpPingCtlTrapGeneration,
        juniAtmVpPingSentProbes,
        juniAtmVpPingProbeResponses,
        juniAtmVpPingStartTime,
        juniAtmVpPingMinRtt,
        juniAtmVpPingMaxRtt,
        juniAtmVpPingAverageRtt }
    STATUS      current
    DESCRIPTION
        "A collection of object providing management of ATM VPL Ping testing in
        a Juniper product."
    ::= { juniAtmGroups 7 }                                        -- JUNOSe 3.2

juniAtmVcPingControlGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmVcPingProbeCount,
        juniAtmVcPingTimeOut,
        juniAtmVcPingCtlTrapGeneration,
        juniAtmVcPingSentProbes,
        juniAtmVcPingProbeResponses,
        juniAtmVcPingStartTime,
        juniAtmVcPingMinRtt,
        juniAtmVcPingMaxRtt,
        juniAtmVcPingAverageRtt }
    STATUS      current
    DESCRIPTION
        "A collection of object providing management of ATM VCL Ping testing in
        a Juniper product."
    ::= { juniAtmGroups 8 }                                        -- JUNOSe 3.2

juniAtmPingTrapGroup  NOTIFICATION-GROUP
    NOTIFICATIONS {
        juniAtmVpPingTestCompleted,
        juniAtmVcPingTestCompleted }
    STATUS      current
    DESCRIPTION
        "A collection of notifications supporting ATM Ping testing in a Juniper
        product."
    ::= { juniAtmGroups 9 }                                        -- JUNOSe 3.2

juniAtmGroup2  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,

        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmIfMapGroup,
        juniAtmIfOamCellFilter,

        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmPvcStatsInPacketUnknownProtocol,

        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci,
        juniAtmIfCapabilityOamCellFilter }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM interfaces
        in a Juniper product.  This group became obsolete when support was
        added for connection admission control (CAC)."
    ::= { juniAtmGroups 10 }                                       -- JUNOSe 3.2

juniAtmTrafficShapingGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfVccTrafficShapingCdvt,
        juniAtmSubIfVccTrafficShapingClp0,
        juniAtmSubIfVccTrafficShapingTagging,
        juniAtmSubIfVccTrafficShapingPoliceObserve,
        juniAtmSubIfVccTrafficShapingPacketShaping }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing management of ATM traffic shaping in
        a Juniper product."
    ::= { juniAtmGroups 11 }                                       -- JUNOSe 3.3

juniAtmGroup3  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,

        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmIfMapGroup,
        juniAtmIfCacAdminState,
        juniAtmIfCacUbrWeight,
        juniAtmIfCacSubscriptionBandwidth,
        juniAtmIfCacAvailableBandwidth,
        juniAtmIfOamCellFilter,

        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmPvcStatsInPacketUnknownProtocol,

        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci,
        juniAtmIfCapabilityOamCellFilter }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM interfaces
        in a Juniper product.  This group became obsolete when support was added
        for connection admission control (CAC) used bandwidth."
    ::= { juniAtmGroups 12 }                                       -- JUNOSe 3.4

juniAtmGroup4  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,

        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmIfMapGroup,
        juniAtmIfCacAdminState,
        juniAtmIfCacUbrWeight,
        juniAtmIfCacSubscriptionBandwidth,
        juniAtmIfCacAvailableBandwidth,
        juniAtmIfOamCellFilter,
        juniAtmIfCacUsedBandwidthUpper,
        juniAtmIfCacUsedBandwidthLower,

        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmPvcStatsInPacketUnknownProtocol,

        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci,
        juniAtmIfCapabilityOamCellFilter }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM interfaces
        in a Juniper product.  This group became obsolete when CAC recieve
        bandwith and E164 public addressing objects were added."
    ::= { juniAtmGroups 13 }                                       -- JUNOSe 4.0

juniAtmSvcGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmIfSvcSignallingVpi,
        juniAtmIfSvcSignallingVci,
        juniAtmIfSvcSignallingVcd,
        juniAtmIfSvcSignallingAdminStatus,

        juniAtmSubIfSvcRowStatus,
        juniAtmSubIfSvcConfigDestAtmAddress,
        juniAtmSubIfSvcConfigCircuitType,
        juniAtmSubIfSvcConfigServiceCategory,
        juniAtmSubIfSvcConfigPcr,
        juniAtmSubIfSvcConfigScr,
        juniAtmSubIfSvcConfigMbs,
        juniAtmSubIfSvcConfigCdvt,
        juniAtmSubIfSvcConfigClp0,
        juniAtmSubIfSvcConfigTagging,
        juniAtmSubIfSvcConfigObserve,
        juniAtmSubIfSvcConfigPacketDiscard }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM SVC
        interfaces in a Juniper product.  This group became obsolete when E164
        public addressing support was added."
    ::= { juniAtmGroups 14 }                                       -- JUNOSe 4.0

juniAtmSubIfGroup3  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfNextIfIndex,

        juniAtmSubIfRowStatus,
        juniAtmSubIfDistinguisher,
        juniAtmSubIfLowerIfIndex,
        juniAtmSubIfNbma,
        juniAtmSubIfAddress,

        juniAtmSubIfVccRowStatus,
        juniAtmSubIfVccVcd,
        juniAtmSubIfVccType,
        juniAtmSubIfVccServiceCategory,
        juniAtmSubIfVccPcr,
        juniAtmSubIfVccScr,
        juniAtmSubIfVccMbs,
        juniAtmSubIfInverseArp,
        juniAtmSubIfInverseArpRefresh,

        juniAtmCircuitOamAdminStatus,
        juniAtmCircuitOamLoopbackOperStatus,
        juniAtmCircuitVcOamOperStatus,
        juniAtmCircuitOamLoopbackFrequency,
        juniAtmCircuitInOamF5Cells,
        juniAtmCircuitInOamCellsDropped,
        juniAtmCircuitOutOamF5Cells,
        juniAtmCircuitInOamF5EndToEndLoopbackCells,
        juniAtmCircuitInOamF5SegmentLoopbackCells,
        juniAtmCircuitInOamF5AisCells,
        juniAtmCircuitInOamF5RdiCells,
        juniAtmCircuitOutOamF5EndToEndLoopbackCells,
        juniAtmCircuitOutOamF5SegmentLoopbackCells,
        juniAtmCircuitOutOamF5RdiCells }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM
        subinterfaces in a Juniper product.  This group became obsolete when
        juniAtmSubIfMtu was added."
    ::= { juniAtmGroups 15 }                                       -- JUNOSe 4.0

juniAtmGroup5  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,

        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmIfMapGroup,
        juniAtmIfCacAdminState,
        juniAtmIfCacUbrWeight,
        juniAtmIfCacSubscriptionBandwidth,
        juniAtmIfCacAvailableBandwidth,
        juniAtmIfCacAvailableBandwidthRx,
        juniAtmIfE164Autoconversion,
        juniAtmIfE164Gateway,
        juniAtmIfE164OneToOneAddrTrans,

        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmPvcStatsInPacketUnknownProtocol,

        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM interfaces
        in a Juniper product.  This group became obsolete when ATM VP
        description support was added."
    ::= { juniAtmGroups 16 }                                       -- JUNOSe 4.1

juniAtmSvcGroup2  OBJECT-GROUP
    OBJECTS {
        juniAtmIfSvcSignallingVpi,
        juniAtmIfSvcSignallingVci,
        juniAtmIfSvcSignallingVcd,
        juniAtmIfSvcSignallingAdminStatus,

        juniAtmSubIfSvcRowStatus,
        juniAtmSubIfSvcConfigDestAtmAddress,
        juniAtmSubIfSvcConfigCircuitType,
        juniAtmSubIfSvcConfigServiceCategory,
        juniAtmSubIfSvcConfigPcr,
        juniAtmSubIfSvcConfigScr,
        juniAtmSubIfSvcConfigMbs,
        juniAtmSubIfSvcConfigClp0,
        juniAtmSubIfSvcConfigTagging,
        juniAtmSubIfSvcConfigPacketDiscard,
        juniAtmSubIfSvcConfigDestE164Address }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing management of ATM SVC interfaces in a
        Juniper product."
    ::= { juniAtmGroups 17 }                                       -- JUNOSe 4.1

juniAtmPnniGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmIfPnniRccVpi,
        juniAtmIfPnniRccVci,
        juniAtmIfPnniRccVcd,
        juniAtmIfPnniRccAdminStatus }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing management of PNNI Routing Control
        Channels in a Juniper product."
    ::= { juniAtmGroups 18 }                                       -- JUNOSe 4.1

juniAtmSubIfGroup4  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfNextIfIndex,

        juniAtmSubIfRowStatus,
        juniAtmSubIfDistinguisher,
        juniAtmSubIfLowerIfIndex,
        juniAtmSubIfNbma,
        juniAtmSubIfAddress,
        juniAtmSubIfMtu,

        juniAtmSubIfVccRowStatus,
        juniAtmSubIfVccVcd,
        juniAtmSubIfVccType,
        juniAtmSubIfVccServiceCategory,
        juniAtmSubIfVccPcr,
        juniAtmSubIfVccScr,
        juniAtmSubIfVccMbs,
        juniAtmSubIfInverseArp,
        juniAtmSubIfInverseArpRefresh,

        juniAtmCircuitOamAdminStatus,
        juniAtmCircuitOamLoopbackOperStatus,
        juniAtmCircuitVcOamOperStatus,
        juniAtmCircuitOamLoopbackFrequency,
        juniAtmCircuitInOamF5Cells,
        juniAtmCircuitInOamCellsDropped,
        juniAtmCircuitOutOamF5Cells,
        juniAtmCircuitInOamF5EndToEndLoopbackCells,
        juniAtmCircuitInOamF5SegmentLoopbackCells,
        juniAtmCircuitInOamF5AisCells,
        juniAtmCircuitInOamF5RdiCells,
        juniAtmCircuitOutOamF5EndToEndLoopbackCells,
        juniAtmCircuitOutOamF5SegmentLoopbackCells,
        juniAtmCircuitOutOamF5RdiCells }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM
        subinterfaces in a Juniper product.  This group became obsolete when
        support was added to export the subinterface description to the line
        cards."
    ::= { juniAtmGroups 19 }                                       -- JUNOSe 4.1

juniAtmF4OamCircuitGroup  OBJECT-GROUP
    OBJECTS {
--      End-to-end configs
        juniAtmOamF4FlowEndToEndLoopbackTimer,
        juniAtmOamF4FlowEndToEndCCSink,
        juniAtmOamF4FlowEndToEndCCSource,
        juniAtmOamF4FlowEndToEndRowStatus,
--      Segment configs
        juniAtmOamF4FlowSegmentCCSink,
        juniAtmOamF4FlowSegmentCCSource,
        juniAtmOamF4FlowSegmentRowStatus,

--      End-to-end stats
        juniAtmF4FlowInOamEndAisCells,
        juniAtmF4FlowInOamEndRdiCells,
        juniAtmF4FlowInOamEndCCCells,
        juniAtmF4FlowInOamEndCCActDeActCells,
        juniAtmF4FlowInOamEndLoopbackCells,
        juniAtmF4FlowOutEndRdiCells,
        juniAtmF4FlowOutEndCCCells,
        juniAtmF4FlowOutEndCCActDeActCells,
        juniAtmF4FlowOutEndToEndLoopbackCells,
        juniAtmF4FlowEndActualLoopbackFreq,
        juniAtmF4FlowEndLastTimeChanged,
        juniAtmF4FlowOamEndVpOperationState,
        juniAtmF4FlowOamEndVpAdminState,
        juniAtmF4FlowEndInOamCells,
        juniAtmF4FlowEndOutOamCells,
        juniAtmF4FlowEndInOamCellsDropped,
--      Segment stats
        juniAtmF4FlowInOamSegmentAisCells,
        juniAtmF4FlowInOamSegmentRdiCells,
        juniAtmF4FlowInOamSegmentCCCells,
        juniAtmF4FlowInOamSegmentCCActDeActCells,
        juniAtmF4FlowInOamSegmentLoopbackCells,
        juniAtmF4FlowOutSegmentRdiCells,
        juniAtmF4FlowOutSegmentCCCells,
        juniAtmF4FlowOutSegmentCCActDeActCells,
        juniAtmF4FlowOutSegmentLoopbackCells,
        juniAtmF4FlowSegmentLastTimeChanged,
        juniAtmF4FlowOamSegmentVpOperationState,
        juniAtmF4FlowOamSegmentVpAdminState,
        juniAtmF4FlowSegmentInOamCells,
        juniAtmF4FlowSegmentOutOamCells,
        juniAtmF4FlowSegmentInOamCellsDropped }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM F4 flow OAM
        circuits in a Juniper product."
    ::= { juniAtmGroups 20 }                                       -- JUNOSe 4.1

juniAtmGroup6  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,

        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmIfMapGroup,
        juniAtmIfCacAdminState,
        juniAtmIfCacUbrWeight,
        juniAtmIfCacSubscriptionBandwidth,
        juniAtmIfCacAvailableBandwidth,
        juniAtmIfCacAvailableBandwidthRx,
        juniAtmIfE164Autoconversion,
        juniAtmIfE164Gateway,
        juniAtmIfE164OneToOneAddrTrans,

        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmPvcStatsInPacketUnknownProtocol,

        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci,

        juniAtmVpDescription,
        juniAtmBulkCircuitsNameRowStatus,
        juniAtmBulkCircuitsNameId,
        juniAtmBulkCircuitsIdName,
        juniAtmBulkCircuitsIdNextInstance,
        juniAtmBulkCircuitsRowStatus,
        juniAtmBulkCircuitsMinVpi,
        juniAtmBulkCircuitsMaxVpi,
        juniAtmBulkCircuitsMinVci,
        juniAtmBulkCircuitsMaxVci }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM interfaces 
        in a Juniper product. This group became obsolete when bulk-configuration
        profile override support was added."
    ::= { juniAtmGroups 21 }                                       -- JUNOSe 5.1

juniAtmLocationGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfLocationType,
        juniAtmSubIfLocationIfIndex }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing interface location information in a
        Juniper product."
    ::= { juniAtmGroups 22 }                                       -- JUNOSe 5.2

juniAtmSubIfGroup5  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfNextIfIndex,

        juniAtmSubIfRowStatus,
        juniAtmSubIfDistinguisher,
        juniAtmSubIfLowerIfIndex,
        juniAtmSubIfNbma,
        juniAtmSubIfAddress,
        juniAtmSubIfMtu,
        juniAtmSubIfAdvisoryRxSpeed,

        juniAtmSubIfVccRowStatus,
        juniAtmSubIfVccVcd,
        juniAtmSubIfVccType,
        juniAtmSubIfVccServiceCategory,
        juniAtmSubIfVccPcr,
        juniAtmSubIfVccScr,
        juniAtmSubIfVccMbs,
        juniAtmSubIfInverseArp,
        juniAtmSubIfInverseArpRefresh,

        juniAtmCircuitOamAdminStatus,
        juniAtmCircuitOamLoopbackOperStatus,
        juniAtmCircuitVcOamOperStatus,
        juniAtmCircuitOamLoopbackFrequency,
        juniAtmCircuitInOamF5Cells,
        juniAtmCircuitInOamCellsDropped,
        juniAtmCircuitOutOamF5Cells,
        juniAtmCircuitInOamF5EndToEndLoopbackCells,
        juniAtmCircuitInOamF5SegmentLoopbackCells,
        juniAtmCircuitInOamF5AisCells,
        juniAtmCircuitInOamF5RdiCells,
        juniAtmCircuitOutOamF5EndToEndLoopbackCells,
        juniAtmCircuitOutOamF5SegmentLoopbackCells,
        juniAtmCircuitOutOamF5RdiCells,

        juniAtmSubIfDescriptionExport }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM 
        subinterfaces in a Juniper product."
    ::= { juniAtmGroups 23 }   

juniAtmMartiniGroup  OBJECT-GROUP
    OBJECTS {
        juniAtmMartiniTimeoutTimerValue,
        
        juniAtmSubIfMartiniMaxCellsPerPacket,
        juniAtmSubIfMartiniTimeoutTimerId }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing ATM Martini cell aggregation
        configuration."
    ::= { juniAtmGroups 24 } 

juniAtmGroup7  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,

        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmIfMapGroup,
        juniAtmIfCacAdminState,
        juniAtmIfCacUbrWeight,
        juniAtmIfCacSubscriptionBandwidth,
        juniAtmIfCacAvailableBandwidth,
        juniAtmIfCacAvailableBandwidthRx,
        juniAtmIfE164Autoconversion,
        juniAtmIfE164Gateway,
        juniAtmIfE164OneToOneAddrTrans,

        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmPvcStatsInPacketUnknownProtocol,

        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci,

        juniAtmVpDescription,
        juniAtmBulkCircuitsNameRowStatus,
        juniAtmBulkCircuitsNameId,
        juniAtmBulkCircuitsIdName,
        juniAtmBulkCircuitsIdNextInstance,
        juniAtmBulkCircuitsRowStatus,
        juniAtmBulkCircuitsMinVpi,
        juniAtmBulkCircuitsMaxVpi,
        juniAtmBulkCircuitsMinVci,
        juniAtmBulkCircuitsMaxVci,
        juniAtmBulkCircuitsAdminState,

    	juniAtmProfileOverrideAssignIfCircuitRowStatus,
    	juniAtmProfileOverrideAssignIfCircuitProfileId,
        juniAtmProfileOverrideAssignIfCircuitOperStatus }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM 
        interfaces in a Juniper product."
    ::= { juniAtmGroups 25 }                                       -- JUNOSe 6.1

juniAtmGroup8  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,
        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmIfMapGroup,
        juniAtmIfCacAdminState,
        juniAtmIfCacUbrWeight,
        juniAtmIfCacSubscriptionBandwidth,
        juniAtmIfCacAvailableBandwidth,

        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmPvcStatsInPacketUnknownProtocol,

        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci,

        juniAtmVpDescription,
        juniAtmBulkCircuitsNameRowStatus,
        juniAtmBulkCircuitsNameId,
        juniAtmBulkCircuitsIdName,
        juniAtmBulkCircuitsIdNextInstance,
        juniAtmBulkCircuitsRowStatus,
        juniAtmBulkCircuitsMinVpi,
        juniAtmBulkCircuitsMaxVpi,
        juniAtmBulkCircuitsMinVci,
        juniAtmBulkCircuitsMaxVci,
        juniAtmBulkCircuitsAdminState,

    	juniAtmProfileOverrideAssignIfCircuitRowStatus,
    	juniAtmProfileOverrideAssignIfCircuitProfileId,
        juniAtmProfileOverrideAssignIfCircuitOperStatus }
    STATUS      obsolete
    DESCRIPTION
        "A collection of objects providing management of ATM interfaces in a
        Juniper product."
    ::= { juniAtmGroups 26 }                                       -- JUNOSe 7.0


juniAtmVpStatsGroup  OBJECT-GROUP
    OBJECTS {
		juniAtmVpStatsInCells,
		juniAtmVpStatsInPackets,
		juniAtmVpStatsInPacketOctets,
		juniAtmVpStatsOutCells,
		juniAtmVpStatsOutPackets,
		juniAtmVpStatsOutPacketOctets,
		juniAtmVpStatsInPacketErrors,
		juniAtmVpStatsOutPacketErrors,
		juniAtmVpStatsInPacketDiscards,
		juniAtmVpStatsInPacketOctetDiscards,
		juniAtmVpStatsInPacketUnknownProtocol,
		juniAtmVpStatsCrcErrors,
		juniAtmVpStatsSarTimeouts,
		juniAtmVpStatsOverSizedPackets}
    STATUS      current
    DESCRIPTION
        "A collection of objects providing ATM VP level statistics."
    ::= { juniAtmGroups 27 }                                       -- JUNOSe 7.1

juniAtmSubIfGroup6  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfNextIfIndex,
        juniAtmSubIfRowStatus,
        juniAtmSubIfDistinguisher,
        juniAtmSubIfLowerIfIndex,
        juniAtmSubIfNbma,
        juniAtmSubIfAddress,
        juniAtmSubIfMtu,
        juniAtmSubIfAdvisoryRxSpeed,
        juniAtmSubIfVccRowStatus,
        juniAtmSubIfVccVcd,
        juniAtmSubIfVccType,
        juniAtmSubIfVccServiceCategory,
        juniAtmSubIfVccPcr,
        juniAtmSubIfVccScr,
        juniAtmSubIfVccMbs,
        juniAtmSubIfInverseArp,
        juniAtmSubIfInverseArpRefresh,
        juniAtmCircuitOamAdminStatus,
        juniAtmCircuitOamLoopbackOperStatus,
        juniAtmCircuitVcOamOperStatus,
        juniAtmCircuitOamLoopbackFrequency,
        juniAtmCircuitInOamF5Cells,
        juniAtmCircuitInOamCellsDropped,
        juniAtmCircuitOutOamF5Cells,
        juniAtmCircuitInOamF5EndToEndLoopbackCells,
        juniAtmCircuitInOamF5SegmentLoopbackCells,
        juniAtmCircuitInOamF5AisCells,
        juniAtmCircuitInOamF5RdiCells,
        juniAtmCircuitOutOamF5EndToEndLoopbackCells,
        juniAtmCircuitOutOamF5SegmentLoopbackCells,
        juniAtmCircuitOutOamF5RdiCells,
        juniAtmCircuitInOamF5EndToEndLoopbackCmds,
        juniAtmCircuitInOamF5EndToEndLoopbackRsps,    
        juniAtmCircuitInOamF5SegmentLoopbackCmds,
        juniAtmCircuitInOamF5SegmentLoopbackRsps,    
        juniAtmCircuitOutOamF5EndToEndLoopbackCmds,
        juniAtmCircuitOutOamF5EndToEndLoopbackRsps,
        juniAtmCircuitOutOamF5SegmentLoopbackCmds,
        juniAtmCircuitOutOamF5SegmentLoopbackRsps,
        juniAtmCircuitOamUpCount,
        juniAtmCircuitOamDownCount,
        juniAtmCircuitOamRetryFrequency,
        juniAtmCircuitOamAlarmDownCount,
        juniAtmCircuitOamAlarmClearTimeout,
        juniAtmSubIfDescriptionExport }
    STATUS      obsolete
    DESCRIPTION
        "Obsolete collection of objects providing management of ATM 
        subinterfaces in a Juniper product. This group became obsolete
        when ATM SVC support was removed."

    ::= { juniAtmGroups 28 }                                       -- JUNOSe 7.1

juniAtmF4OamCircuitGroup2  OBJECT-GROUP
    OBJECTS {
        juniAtmOamF4FlowEndToEndLoopbackTimer,
        juniAtmOamF4FlowEndToEndCCSink,
        juniAtmOamF4FlowEndToEndCCSource,
        juniAtmOamF4FlowEndToEndRowStatus,
        juniAtmOamF4FlowSegmentCCSink,
        juniAtmOamF4FlowSegmentCCSource,
        juniAtmOamF4FlowSegmentRowStatus,
        juniAtmF4FlowInOamEndAisCells,
        juniAtmF4FlowInOamEndRdiCells,
        juniAtmF4FlowInOamEndCCCells,
        juniAtmF4FlowInOamEndCCActDeActCells,
        juniAtmF4FlowInOamEndLoopbackCells,
        juniAtmF4FlowOutEndRdiCells,
        juniAtmF4FlowOutEndCCCells,
        juniAtmF4FlowOutEndCCActDeActCells,
        juniAtmF4FlowOutEndToEndLoopbackCells,
        juniAtmF4FlowEndActualLoopbackFreq,
        juniAtmF4FlowEndLastTimeChanged,
        juniAtmF4FlowOamEndVpOperationState,
        juniAtmF4FlowOamEndVpAdminState,
        juniAtmF4FlowEndInOamCells,
        juniAtmF4FlowEndOutOamCells,
        juniAtmF4FlowEndInOamCellsDropped,
        juniAtmF4FlowInOamSegmentAisCells,
        juniAtmF4FlowInOamSegmentRdiCells,
        juniAtmF4FlowInOamSegmentCCCells,
        juniAtmF4FlowInOamSegmentCCActDeActCells,
        juniAtmF4FlowInOamSegmentLoopbackCells,
        juniAtmF4FlowOutSegmentRdiCells,
        juniAtmF4FlowOutSegmentCCCells,
        juniAtmF4FlowOutSegmentCCActDeActCells,
        juniAtmF4FlowOutSegmentLoopbackCells,
        juniAtmF4FlowSegmentLastTimeChanged,
        juniAtmF4FlowOamSegmentVpOperationState,
        juniAtmF4FlowOamSegmentVpAdminState,
        juniAtmF4FlowSegmentInOamCells,
        juniAtmF4FlowSegmentOutOamCells,
        juniAtmF4FlowSegmentInOamCellsDropped,
        juniAtmF4FlowEndToEndInLoopbackCmds,
        juniAtmF4FlowEndToEndInLoopbackRsps,
        juniAtmF4FlowSegmentInLoopbackCmds,
        juniAtmF4FlowSegmentInLoopbackRsps,
        juniAtmF4FlowEndToEndOutLoopbackCmds,
        juniAtmF4FlowEndToEndOutLoopbackRsps,
        juniAtmF4FlowSegmentOutLoopbackCmds,
        juniAtmF4FlowSegmentOutLoopbackRsps }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing management of ATM F4 flow OAM
        circuits in a Juniper product."
    ::= { juniAtmGroups 29 }                                       -- JUNOSe 7.1

juniAtmGroup9  OBJECT-GROUP
    OBJECTS {
        juniAtmNextIfIndex,
        juniAtmIfRowStatus,
        juniAtmIfLowerIfIndex,
        juniAtmIfIlmiVpi,
        juniAtmIfIlmiVci,
        juniAtmIfIlmiVcd,
        juniAtmIfIlmiPollFrequency,
        juniAtmIfIlmiAdminState,
        juniAtmIfUniVersion,
        juniAtmIfOamCellRxAdminState,
        juniAtmIfInCells,
        juniAtmIfOutCells,
        juniAtmIfVcCount,
        juniAtmIfMapGroup,
        juniAtmIfCacAdminState,
        juniAtmIfCacUbrWeight,
        juniAtmIfCacSubscriptionBandwidth,
        juniAtmIfCacAvailableBandwidth,
		juniAtmIfAssociatedVcClassId,

        juniAtmPvcStatsInCells,
        juniAtmPvcStatsInCellOctets,
        juniAtmPvcStatsInPackets,
        juniAtmPvcStatsInPacketOctets,
        juniAtmPvcStatsOutCells,
        juniAtmPvcStatsOutCellOctets,
        juniAtmPvcStatsOutPackets,
        juniAtmPvcStatsOutPacketOctets,
        juniAtmPvcStatsInCellErrors,
        juniAtmPvcStatsinPacketErrors,
        juniAtmPvcStatsOutCellErrors,
        juniAtmPvcStatsOutPacketErrors,
        juniAtmPvcStatsInPacketDiscards,
        juniAtmPvcStatsInPacketOctetDiscards,
        juniAtmPvcStatsInPacketUnknownProtocol,

        juniAtmIfCapabilityTrafficShaping,
        juniAtmIfCapabilityOam,
        juniAtmIfCapabilityDefaultVcPerVp,
        juniAtmIfCapabilityNumVpiVciBits,
        juniAtmIfCapabilityMaxVcd,
        juniAtmIfCapabilityMaxVpi,
        juniAtmIfCapabilityMaxVci,

        juniAtmVpDescription,
        juniAtmBulkCircuitsNameRowStatus,
        juniAtmBulkCircuitsNameId,
        juniAtmBulkCircuitsIdName,
        juniAtmBulkCircuitsIdNextInstance,
        juniAtmBulkCircuitsRowStatus,
        juniAtmBulkCircuitsMinVpi,
        juniAtmBulkCircuitsMaxVpi,
        juniAtmBulkCircuitsMinVci,
        juniAtmBulkCircuitsMaxVci,
        juniAtmBulkCircuitsAdminState,

    	juniAtmProfileOverrideAssignIfCircuitRowStatus,
    	juniAtmProfileOverrideAssignIfCircuitProfileId,
		juniAtmProfileOverrideAssignIfCircuitOperStatus }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing management of ATM interfaces in a
        Juniper product."
    ::= { juniAtmGroups 30 }                                       -- JUNOSe 7.3

juniAtmSubIfGroup7  OBJECT-GROUP
    OBJECTS {
        juniAtmSubIfNextIfIndex,
        juniAtmSubIfRowStatus,
        juniAtmSubIfDistinguisher,
        juniAtmSubIfLowerIfIndex,
        juniAtmSubIfNbma,
        juniAtmSubIfAddress,
        juniAtmSubIfMtu,
        juniAtmSubIfAdvisoryRxSpeed,
		juniAtmSubIfAssociatedVcClassId,
        juniAtmSubIfVccRowStatus,
        juniAtmSubIfVccVcd,
        juniAtmSubIfVccType,
        juniAtmSubIfVccServiceCategory,
        juniAtmSubIfVccPcr,
        juniAtmSubIfVccScr,
        juniAtmSubIfVccMbs,
        juniAtmSubIfInverseArp,
        juniAtmSubIfInverseArpRefresh,
		juniAtmSubIfVccAssociatedVcClassId,
        juniAtmCircuitOamAdminStatus,
        juniAtmCircuitOamLoopbackOperStatus,
        juniAtmCircuitVcOamOperStatus,
        juniAtmCircuitOamLoopbackFrequency,
        juniAtmCircuitInOamF5Cells,
        juniAtmCircuitInOamCellsDropped,
        juniAtmCircuitOutOamF5Cells,
        juniAtmCircuitInOamF5EndToEndLoopbackCells,
        juniAtmCircuitInOamF5SegmentLoopbackCells,
        juniAtmCircuitInOamF5AisCells,
        juniAtmCircuitInOamF5RdiCells,
        juniAtmCircuitOutOamF5EndToEndLoopbackCells,
        juniAtmCircuitOutOamF5SegmentLoopbackCells,
        juniAtmCircuitOutOamF5RdiCells,
        juniAtmCircuitInOamF5EndToEndLoopbackCmds,
        juniAtmCircuitInOamF5EndToEndLoopbackRsps,    
        juniAtmCircuitInOamF5SegmentLoopbackCmds,
        juniAtmCircuitInOamF5SegmentLoopbackRsps,    
        juniAtmCircuitOutOamF5EndToEndLoopbackCmds,
        juniAtmCircuitOutOamF5EndToEndLoopbackRsps,
        juniAtmCircuitOutOamF5SegmentLoopbackCmds,
        juniAtmCircuitOutOamF5SegmentLoopbackRsps,
        juniAtmCircuitOamUpCount,
        juniAtmCircuitOamDownCount,
        juniAtmCircuitOamRetryFrequency,
        juniAtmCircuitOamAlarmDownCount,
        juniAtmCircuitOamAlarmClearTimeout,
        juniAtmSubIfDescriptionExport }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing management of ATM subinterfaces in a
        Juniper product."
    ::= { juniAtmGroups 31 }                                       -- JUNOSe 7.3

juniAtmVcClassGroup  OBJECT-GROUP
    OBJECTS {
		juniAtmVcClassName,	    
		juniAtmVcClassNameRowStatus,
		juniAtmVcClassNameId,
		juniAtmVcClassIdName, 
		juniAtmVcClassVccType,
		juniAtmVcClassVccServiceCategory,
		juniAtmVcClassVccPcr,juniAtmVcClassVccScr,
		juniAtmVcClassVccMbs,
		juniAtmVcClassVccOamAdminStatus,
		juniAtmVcClassVccOamLoopbackFrequency,
		juniAtmVcClassVccOamUpCount,
		juniAtmVcClassVccOamDownCount,
		juniAtmVcClassVccOamRetryFrequency,
		juniAtmVcClassVccOamAlarmDownCount,
		juniAtmVcClassVccOamAlarmClearTimeout,
		juniAtmVcClassVccInverseArp,
		juniAtmVcClassVccInverseArpRefresh}
    STATUS 		current
	DESCRIPTION 
		"A collection of objects providing management of ATM VC class in a 
		Juniper product."                                       -- JUNOSe7.3
	::= { juniAtmGroups 32 }  		
END