summaryrefslogtreecommitdiff
path: root/MIBS/linksys/LINKSYS-POE-MIB
blob: 2c320eb72937a9eff023106fc157145734c1d29c (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
LINKSYS-POE-MIB DEFINITIONS ::= BEGIN

-- Title:               Linksys LOCALIZATION ROS
--                      This Private MIB is enhancement for rfc3621.txt - Power Ethernet Mib
-- Version:             7.50
-- Date:                28 Nov 2005

IMPORTS
    rnd                                 FROM LINKSYS-MIB
    DisplayString, TruthValue           FROM SNMPv2-TC
    OBJECT-TYPE, MODULE-IDENTITY        FROM SNMPv2-SMI;


rlPoe    MODULE-IDENTITY
         LAST-UPDATED "200911260000Z"
         ORGANIZATION "Linksys."
         CONTACT-INFO
                "Linksys.com"
         DESCRIPTION
                "Add a new field in the PoE MIB to indicate Max power allocation allowed"
         REVISION "201006020000Z"
         DESCRIPTION
                "The private MIB module definition for Power Over Ethernet."
         REVISION "200911260000Z"
         DESCRIPTION
                "Initial revision."
        ::= { rnd 108 }

rlPethPsePortTable OBJECT-TYPE
    SYNTAX SEQUENCE OF RlPethPsePortEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        " The table listing additional information for Power Over Ethernet ports."
    ::= {rlPoe 1 }

rlPethPsePortEntry  OBJECT-TYPE
    SYNTAX      RlPethPsePortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        " An entry in the rlPethPsePortTable."
    INDEX    { rlPethPsePortGroupIndex , rlPethPsePortIndex  }
    ::= {rlPethPsePortTable  1 }

RlPethPsePortEntry ::= SEQUENCE {
    rlPethPsePortGroupIndex             INTEGER,
    rlPethPsePortIndex                  INTEGER,
    rlPethPsePortOutputVoltage          INTEGER,
    rlPethPsePortOutputCurrent          INTEGER,
    rlPethPsePortOutputPower            INTEGER,
    rlPethPsePortPowerLimit             INTEGER,
    rlPethPsePortStatus                 INTEGER,
    rlPethPsePortStatusDescription      DisplayString,
    rlPethPsePortOperPowerLimit         INTEGER,
    rlPethPsePortSupportPoePlus         TruthValue,
    rlPethPsePortTimeRangeName          DisplayString,
    rlPethPsePortOperStatus             TruthValue,
    rlPethPsePortMaxPowerAllocAllowed   INTEGER,
    rlPethPsePortSupportPoe             TruthValue
}

rlPethPsePortGroupIndex OBJECT-TYPE
    SYNTAX      INTEGER (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This variable uniquely identifies the group
         containing the port to which a power Ethernet PSE is
         connected.  Group means box in the stack, module in a
         rack and the value 1 MUST be used for non-modular devices.
         Furthermore, the same value MUST be used in this variable,
         pethMainPseGroupIndex, and pethNotificationControlGroupIndex
         to refer to a given box in a stack or module in the rack."
    ::= { rlPethPsePortEntry 1 }

rlPethPsePortIndex OBJECT-TYPE
    SYNTAX      INTEGER (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This variable uniquely identifies the power Ethernet PSE
         port within group pethPsePortGroupIndex to which the
         power Ethernet PSE entry is connected."
    ::= { rlPethPsePortEntry 2 }

rlPethPsePortOutputVoltage OBJECT-TYPE
    SYNTAX      INTEGER (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex."
    ::= { rlPethPsePortEntry 3 }

rlPethPsePortOutputCurrent OBJECT-TYPE
    SYNTAX      INTEGER (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates on the output current level in milli amper from rlPethPsePortIndex."
    ::= { rlPethPsePortEntry 4 }

rlPethPsePortOutputPower OBJECT-TYPE
    SYNTAX      INTEGER (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates on the output power level in milli watts from rlPethPsePortIndex."
    ::= { rlPethPsePortEntry 5 }

rlPethPsePortPowerLimit OBJECT-TYPE
    SYNTAX      INTEGER (0..2147483647)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex."
    ::= { rlPethPsePortEntry 6 }

rlPethPsePortStatus OBJECT-TYPE
    SYNTAX      INTEGER (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates on the hardware status of rlPethPsePortIndex."
    ::= { rlPethPsePortEntry 7 }

rlPethPsePortStatusDescription OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..80))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates the description of the hardware status of rlPethPsePortIndex."
    ::= { rlPethPsePortEntry 8 }

rlPethPsePortOperPowerLimit OBJECT-TYPE
    SYNTAX      INTEGER (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex."
    ::= { rlPethPsePortEntry 9 }

rlPethPsePortSupportPoePlus OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates if the port supports poe plus."
    ::= { rlPethPsePortEntry 10 }

rlPethPsePortTimeRangeName OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This variable is used to bind PoE port to time range."
    ::= { rlPethPsePortEntry 11 }

rlPethPsePortOperStatus OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status."
    ::= { rlPethPsePortEntry 12 }

rlPethPsePortMaxPowerAllocAllowed OBJECT-TYPE
    SYNTAX      INTEGER (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex."
    ::= { rlPethPsePortEntry 13 }

rlPethPsePortSupportPoe OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates if the port is a poe port"
    ::= { rlPethPsePortEntry 14 }

rlPethMainPseTable OBJECT-TYPE
    SYNTAX SEQUENCE OF RlPethMainPseEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        " The table listing additional read - only information for Power Over Ethernet."
    ::= {rlPoe 2 }

rlPethMainPseEntry  OBJECT-TYPE
    SYNTAX      RlPethMainPseEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        " An entry in the rlPethMainPseTable."
    INDEX    { rlPethMainPseGroupIndex }
    ::= {rlPethMainPseTable  1 }

RlPethMainPseEntry ::= SEQUENCE {
    rlPethMainPseGroupIndex          INTEGER,
    rlPethMainPseSwVersion           DisplayString,
    rlPethMainPseHwVersion           DisplayString,
    rlPethMainPseHwType              INTEGER,
    rlPethMainPsePowerGuardBand      INTEGER

}

rlPethMainPseGroupIndex OBJECT-TYPE
    SYNTAX      INTEGER (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This variable uniquely identifies the group
         containing the port to which a power Ethernet PSE is
         connected.  Group means box in the stack, module in a
         rack and the value 1 MUST be used for non-modular devices.
         Furthermore, the same value MUST be used in this variable,
         pethMainPseGroupIndex, and pethNotificationControlGroupIndex
         to refer to a given box in a stack or module in the rack."
    ::= { rlPethMainPseEntry 1 }

rlPethMainPseSwVersion OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..20))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable identifies the MCU SW version."
    ::= { rlPethMainPseEntry 2 }

rlPethMainPseHwVersion OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..20))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable identifies the MCU HW version."
    ::= { rlPethMainPseEntry 3 }

rlPethMainPseHwType OBJECT-TYPE
    SYNTAX  INTEGER {
        enhanced(1),
        plus(2),
        auto(3),
        nonPoe(4),
        enhancedPlus(5)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable identifies the MCU HW type (enhanced, plus, none)."
    ::= { rlPethMainPseEntry 4 }

rlPethMainPsePowerGuardBand OBJECT-TYPE
    SYNTAX      INTEGER (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable identifies the guard band in [W] for not connecting
         additional ports."
    ::= { rlPethMainPseEntry 5 }

rlPethPowerPseTable OBJECT-TYPE
    SYNTAX SEQUENCE OF RlPethPowerPseEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        " The table listing additional read-write information for Power Over Ethernet."
    ::= {rlPoe 3 }

rlPethPowerPseEntry  OBJECT-TYPE
    SYNTAX      RlPethPowerPseEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        " An entry in the rlPethPowerPseTable."
    INDEX    { rlPethPowerPseGroupIndex }
    ::= {rlPethPowerPseTable  1 }

RlPethPowerPseEntry ::= SEQUENCE {
    rlPethPowerPseGroupIndex          INTEGER,
    rlPethPowerPsePower               INTEGER,
    rlPethPowerPseRpsPower            INTEGER,
    rlPethPowerPsePowerManagementMode INTEGER,
    rlPethPowerPsedisconnectMethod    INTEGER,
    rlPethPowerPseTemperatureSensor   INTEGER,
    rlPethPowerPseInrushTestEnabled   INTEGER
}

rlPethPowerPseGroupIndex OBJECT-TYPE
    SYNTAX      INTEGER (1..8)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This variable uniquely identifies the group
         containing the port to which a power Ethernet PSE is
         connected.  Group means box in the stack, module in a
         rack and the value 1 MUST be used for non-modular devices.
         Furthermore, the same value MUST be used in this variable,
         PethPowerPseGroupIndex, and pethNotificationControlGroupIndex
         to refer to a given box in a stack or module in the rack."
    ::= { rlPethPowerPseEntry 1 }


-- depricated
rlPethPowerPsePower OBJECT-TYPE
    SYNTAX      INTEGER {
        none(0),
        ps1(1),
        ps2(2),
        ps3(3)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This variable identifies the maximum power in [W] supplied by PSE."
    ::= { rlPethPowerPseEntry 2 }

-- depricated
rlPethPowerPseRpsPower OBJECT-TYPE
    SYNTAX      INTEGER {
        none(0),
        rps1(1),
        rps2(2),
        rps3(3)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This variable identifies the maximum power in [W] supplied by PSE + RPS."
    ::= { rlPethPowerPseEntry 3 }

rlPethPowerPsePowerManagementMode OBJECT-TYPE
    SYNTAX      INTEGER {
        portlimit(0),
        classlimit(5),
        maxlimit(6)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This variable identifies power management mode."
    ::= { rlPethPowerPseEntry 4 }

rlPethPowerPsedisconnectMethod OBJECT-TYPE
    SYNTAX      INTEGER {
        lowestpriority(0),
        nextport(1)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This variable identifies disconnect method. "
    ::= { rlPethPowerPseEntry 5 }

rlPethPowerPseTemperatureSensor OBJECT-TYPE
    SYNTAX      INTEGER (-200..200)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable identifies the pd temperature sensor. "
    ::= { rlPethPowerPseEntry 6 }

rlPethPowerPseInrushTestEnabled OBJECT-TYPE
    SYNTAX      INTEGER {
        enabled(0),
        disabled(1)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This variable identifies if HW inrush test will be disabled.
        by default HW inrush test is enabled."
    ::= { rlPethPowerPseEntry 7 }

END