summaryrefslogtreecommitdiff
path: root/MIBS/meinberg/MBG-SNMP-FDMXPT-MIB
blob: 0b820ae552dbbbf86674f314c091d0ef2c58981c (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
MBG-SNMP-FDMXPT-MIB DEFINITIONS ::= BEGIN

--
-- Top-level infrastructure of the MBG FDMXPT-SNMP project enterprise MIB tree
--

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE FROM SNMPv2-SMI
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
    DisplayString                           FROM SNMPv2-TC

   mbgSnmpRoot FROM MBG-SNMP-ROOT-MIB;

mbgFDM MODULE-IDENTITY
    LAST-UPDATED "201201250000Z"
    ORGANIZATION "www.meinberg.de"
    CONTACT-INFO
	 "postal:   Meinberg Funkuhren
                    Auf der Landwehr 22
                    31812 Bad Pyrmont
	            Germany

          email:    info@meinberg.de"
    DESCRIPTION
	"Top-level infrastructure of the MBG-SNMP project enterprise MIB tree"
    REVISION     "201201250000Z"
    DESCRIPTION
       "Update to new format using MBG-SNMP-ROOT-MIB"
    REVISION     "200601200000Z"
    DESCRIPTION
       "Covering FDMXPT modules from Meinberg"
    ::= { mbgSnmpRoot 15 }


--
--  MBG-SNMP enterprise-specific management objects
--
-- 
-- Copy everything from here into your MBG-SNMP-MIB.txt file, if you are using several different SNMP-supporting Meinberg systems 
--

mbgFDMData		OBJECT IDENTIFIER ::= {mbgFDM 2}
mbgFDMTraps             OBJECT IDENTIFIER ::= {mbgFDM 3}



mbgFDMMode OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "current Mode of FDM"
    ::= { mbgFDMData 1 }

mbgFDMModeVal OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "current Mode of FDM as value"
    --- " 0: Normal Operation"
    --- " 1: Direct Mode (no automatic monitoring)"
    --- " 2: Timeout Error (no communication with FDM)"
    --- " 3: Error (check error bits)"
    DEFVAL { 0 }
    ::= { mbgFDMData 2 }

mbgFDMFrequency OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "current powerline frequency in Hz as measured by FDM"
    --- Example: "49.997" represents 49.997 Hz
    ::= { mbgFDMData 3 }

mbgFDMFrequencyVal OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "current powerline frequency in Hz*1000 as value"
    --- Example: 50034 represents 50.034 Hz
    DEFVAL { 0 }
    ::= { mbgFDMData 4 }


mbgFDMRefTime OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "current reference time of FDM"
    --- Example: "15:35:01", is provided by the reference clock (e.g. GPS)
    ::= { mbgFDMData 5 }

mbgFDMPLTime OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "current powerline time of FDM"
    --- Example: "15:35:01", is initially read from the reference clock and then 
    --- the powerline frequency is used as a clock frequency 
    ::= { mbgFDMData 6 }

mbgFDMFreqDev OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Frequency Devidation in Hz"
    --- Example: "-00.002" represents a difference of -0.002 Hz 
    --- (current powerline frequency compared to nominal powerline frequency)
    ::= { mbgFDMData 7 }

mbgFDMFreqDevVal OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "current frequency deviation in Hz*1000 as value"
    --- Example: -22 represents -0.022 Hz
    DEFVAL { 0 }
    ::= { mbgFDMData 8 }

mbgFDMTimeDev OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time Devidation in seconds"
    --- Example: "-00.102" represents a time difference of -102 ms or -0.102 seconds" 
    --- (reftime compared to pltime)
    ::= { mbgFDMData 9 }

mbgFDMTimeDevVal OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "current time deviation in ms"
    --- Example: -22 represents -22 ms
    DEFVAL { 0 }
    ::= { mbgFDMData 10 }

mbgFDMErrorStatus OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The 8 error bits of the FDM in string format"
    --- Example: "00000000" says "no error bits set" 
    --- and "00000101" says Error bits 1 and 3 set
    ::= { mbgFDMData 11 }

--
-- SNMP trap definitions
--

mbgFDMTrapInternalError NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when an internal error occurs (see error bits)"
    ::= { mbgFDMTraps 1 }

mbgFDMTrapNoTimeString NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when no time string can be read from reference clock"
    ::= { mbgFDMTraps 2 }

mbgFDMTrapNo10Mhz NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when the reference frequency is not available"
    ::= { mbgFDMTraps 3 }

mbgFDMTrapNoPPS NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when the reference Pulse Per Second is not available"
    ::= { mbgFDMTraps 4 }
    
mbgFDMTrapNoPowerline NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when powerline frequency could not be detected"
	-- is the powerline connected?
    ::= { mbgFDMTraps 5 }

mbgFDMTrapTimeDeviationOverflow NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when a time deviation overflow happens"
    ::= { mbgFDMTraps 6 }
    
mbgFDMTrapA1Overflow NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when Analog1 overflows"
    ::= { mbgFDMTraps 7 }

mbgFDMTrapA2Overflow NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when Analog2 overflows"
    ::= { mbgFDMTraps 8 }

mbgFDMTrapFreqLimitExceeded NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when the current frequency exceeds the valid frequency range"
    ::= { mbgFDMTraps 9 }

mbgFDMXPTReboot NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when the FDMXPT module starts up"
	-- happens at system startup and if the FDMXPT module reboots
    ::= { mbgFDMTraps 10 }

mbgFDMNormalOperation NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "trap to be sent when the FDM status is OK (Normal Operation)"
	-- happens at system startup and as soon as all error conditions have been cleared
    ::= { mbgFDMTraps 99 }

--
-- Conformance Statements
--


mbgFDMConformance		OBJECT IDENTIFIER ::= { mbgFDM 90 }
mbgFDMCompliances		OBJECT IDENTIFIER ::= { mbgFDMConformance 1 }
mbgFDMGroups			OBJECT IDENTIFIER ::= { mbgFDMConformance 2 }

mbgFDMCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
	"The compliance statement for SNMP entities which implement version 2
        of the XPT MIB"
    MODULE  -- this module
        MANDATORY-GROUPS {
                mbgFDMObjectsGroup,
                mbgFDMTrapsGroup
        }
    ::= { mbgFDMCompliances 1 }


mbgFDMObjectsGroup	OBJECT-GROUP
    OBJECTS {
	mbgFDMMode,
	mbgFDMModeVal,
	mbgFDMFrequency,
	mbgFDMFrequencyVal,
	mbgFDMRefTime,
	mbgFDMPLTime,
	mbgFDMFreqDev,
	mbgFDMFreqDevVal,
	mbgFDMTimeDev,
	mbgFDMTimeDevVal,
	mbgFDMErrorStatus
    }			
    STATUS	current
    DESCRIPTION
	"The collection of objects for the MBG FDMXPT MIB"
	
    ::= { mbgFDMGroups 1 }
    
mbgFDMTrapsGroup 	NOTIFICATION-GROUP
    NOTIFICATIONS {
	mbgFDMTrapInternalError,
	mbgFDMTrapNoTimeString,
        mbgFDMTrapNo10Mhz,
        mbgFDMTrapNoPPS,
        mbgFDMTrapNoPowerline,
        mbgFDMTrapTimeDeviationOverflow,
        mbgFDMTrapA1Overflow,
        mbgFDMTrapA2Overflow,
        mbgFDMTrapFreqLimitExceeded,
        mbgFDMXPTReboot,
        mbgFDMNormalOperation
    }																
    STATUS	current
    DESCRIPTION
	"The collection of traps for the MBG FDMXPT MIB"
	
    ::= { mbgFDMGroups 2 }

END