1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
|
ALCATEL-IND1-PORT-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, Counter64,
NOTIFICATION-TYPE, MODULE-IDENTITY,
TimeTicks, Integer32 FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
ifIndex, ifInErrors, ifOutErrors
FROM IF-MIB
softentIND1Port, cmmEsmDrvTraps
FROM ALCATEL-IND1-BASE
DisplayString FROM SNMPv2-TC;
alcatelIND1PortMIB MODULE-IDENTITY
LAST-UPDATED "200704030000Z"
ORGANIZATION "Alcatel-Lucent"
CONTACT-INFO
"Please consult with Customer Service to ensure the most appropriate
version of this document is used with the products in question:
Alcatel-Lucent, Enterprise Solutions Division
(Formerly Alcatel Internetworking, Incorporated)
26801 West Agoura Road
Agoura Hills, CA 91301-5122
United States Of America
Telephone: North America +1 800 995 2696
Latin America +1 877 919 9526
Europe +31 23 556 0100
Asia +65 394 7933
All Other +1 818 878 4507
Electronic Mail: support@ind.alcatel.com
World Wide Web: http://alcatel-lucent.com/wps/portal/enterprise
File Transfer Protocol: ftp://ftp.ind.alcatel.com/pub/products/mibs"
DESCRIPTION
"This module describes an authoritative enterprise-specific Simple
Network Management Protocol (SNMP) Management Information Base (MIB):
This group contains the configuration information data
for the Ethernet Switching Module.
The right to make changes in specification and other information
contained in this document without prior notice is reserved.
No liability shall be assumed for any incidental, indirect, special, or
consequential damages whatsoever arising from or related to this
document or the information contained herein.
Vendors, end-users, and other interested parties are granted
non-exclusive license to use this specification in connection with
management of the products for which it is intended to be used.
Copyright (C) 1995-2007 Alcatel-Lucent
ALL RIGHTS RESERVED WORLDWIDE"
REVISION "200704030000Z"
DESCRIPTION
"The latest version of this MIB Module."
::= { softentIND1Port 1}
alcatelIND1PortNotifications OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 0 }
alcatelIND1PortMIBObjects OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 1 }
alcatelIND1PortMIBConformance OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 2 }
--
-- alcatelIND1PortMIBObjects
--
esmConfTrap OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 1 }
physicalPort OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 2 }
ddmConfiguration OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 4 }
ddmNotifications OBJECT IDENTIFIER ::= { alcatelIND1PortNotifications 1 }
esmViolationRecovery OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 5 }
esmViolationNotifications OBJECT IDENTIFIER ::= { alcatelIND1PortNotifications 2 }
-- Ethernet Driver object related to Trap *********************
esmDrvTrapDrops OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Partitioned port (separated due to errors)."
::= { esmConfTrap 1 }
-- Ethernet Driver Tables *****************************
-- EsmConf group. This group contains the configuration
-- information data for the Ethernet Switching Module.
-- Implementation of this group is mandantory.
--
-- Note that this MIB can NOT be used for row creation (this
-- would imply that you could override the actual physical
-- characteristics of the physical card!).
esmConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF EsmConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of ESM Physical Port instances."
::= { physicalPort 1 }
esmConfEntry OBJECT-TYPE
SYNTAX EsmConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A ESM Physical Port entry."
INDEX { ifIndex }
::= { esmConfTable 1 }
EsmConfEntry ::= SEQUENCE {
esmPortSlot
Integer32,
esmPortIF
Integer32,
esmPortAutoSpeed
INTEGER,
esmPortAutoDuplexMode
INTEGER,
esmPortCfgSpeed
INTEGER,
esmPortCfgDuplexMode
INTEGER,
esmPortCfgIFG
Integer32,
esmPortPauseSlotTime
Integer32,
esmPortMaxFloodRate
INTEGER,
esmPortFloodMcastEnable
INTEGER,
esmPortCfgMaxFrameSize
Integer32,
esmPortCfgLongEnable
INTEGER,
esmPortCfgRuntEnable
INTEGER,
esmPortCfgRuntSize
Integer32,
esmPortCfgAutoNegotiation
INTEGER,
esmPortCfgCrossover
INTEGER,
esmPortCfgFlow
INTEGER,
esmPortCfgHybridActiveType
INTEGER,
esmPortCfgHybridMode
INTEGER,
esmPortOperationalHybridType
INTEGER,
esmPortCfgMMULowWaterMarkCellSetLimit
INTEGER,
esmPortCfgMMUDynamicCellSetLimit
INTEGER,
esmPortViolationBitMap
BITS,
esmPortViolationClearAll
INTEGER,
esmPortFloodBcastEnable
INTEGER,
esmPortFloodUnknownUcastEnable
INTEGER,
esmPortMaxUnknownUcastFloodRate
INTEGER,
esmPortMaxMcastFloodRate
INTEGER,
esmPortMaxFloodRateLimit
Integer32,
esmPortMaxUnknownUcastFloodRateLimit
Integer32,
esmPortMaxMcastFloodRateLimit
Integer32,
esmPortCfgSFPType
DisplayString
}
esmPortSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical Slot number for this Ethernet Port.
Slot number has been added to be used by the private Trap."
::= { esmConfEntry 1 }
esmPortIF OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The on-board interface number for this Ethernet Port.
Port Number has been added to be used by the private Trap."
::= { esmConfEntry 2 }
esmPortAutoSpeed OBJECT-TYPE
SYNTAX INTEGER {
speed100(1),
speed10(2),
speedAuto(3),
unknown(4),
speed1000(5),
speed10000(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The automatically detected port line speed
of this ESM port."
::= { esmConfEntry 3 }
esmPortAutoDuplexMode OBJECT-TYPE
SYNTAX INTEGER {
fullDuplex(1),
halfDuplex(2),
autoDuplex(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The automatically detected port duplex mode
of this ESM port.
Note: GigaEthernet supports only Full duplex mode.
Default value for 10/100 = Half duplex mode."
::= { esmConfEntry 4 }
esmPortCfgSpeed OBJECT-TYPE
SYNTAX INTEGER {
speed100(1),
speed10(2),
speedAuto(3),
speed1000(5),
speed10000(6),
speedMax100(8),
speedMax1000(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured port line speed of this ESM port."
::= { esmConfEntry 5 }
esmPortCfgDuplexMode OBJECT-TYPE
SYNTAX INTEGER {
fullDuplex(1),
halfDuplex(2),
autoDuplex(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured port duplex mode of this ESM port.
Note: GigaEthernet support only full-duplex."
::= { esmConfEntry 6 }
esmPortCfgIFG OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Contains the setting of Inter-Frame Gap (IFG), in bytes
for receive and transmit.
The range is from 9 to 12 bytes.
Note: The default value changed according to the Port type
Default Bandwidth value
12 bytes 10Mbps 9600 nsec
100Mbps 960 nsec
1Gbps 96 nsec
10Gbps 9.6 nsec."
DEFVAL { 12 }
::= { esmConfEntry 7 }
esmPortPauseSlotTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the number of microseconds the other
end-station waits after the reception
of a pause frame.
Note: Pause Flow control is not available for 10Mbps.
For 100Mbps, the possible value range is
5120 nanosec to 0.3 sec.
For 1Gbps, the possible value range is
512 nanosec to 0.03 sec."
::= { esmConfEntry 8 }
esmPortMaxFloodRate OBJECT-TYPE
SYNTAX INTEGER {
mbps(1),
percentage(2),
pps(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Broadcast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also."
DEFVAL { mbps }
::= { esmConfEntry 9 }
esmPortFloodMcastEnable OBJECT-TYPE
SYNTAX INTEGER {
disableMulticastFlood(2),
enableMulticastFlood(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the maximum flood rate
for multicast."
DEFVAL { disableMulticastFlood }
::= { esmConfEntry 10 }
esmPortCfgMaxFrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure the value of the maximum frame
size allow.
For 10/100:
It is a range between 1518(untagged) and 1553 bytes.
For GigaEthernet:
It is a range between 1518 and 10240 bytes.(OS7700,OS7800,OS8800)
It is a range between 1518 and 9216 bytes.(OS6800)"
::= { esmConfEntry 11 }
esmPortCfgLongEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allow the user to change the maximun Frame size.
Note: It is not configurable for 10/100 Ethernet port."
DEFVAL { disable }
::= { esmConfEntry 12 }
esmPortCfgRuntEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(2),
enable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allow the user to change the minimum Frame size."
DEFVAL { disable }
::= { esmConfEntry 13 }
esmPortCfgRuntSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure the value of the minimum frame
size allow per ports.
The range is 0 to 64."
DEFVAL { 64 }
::= { esmConfEntry 14 }
esmPortCfgAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allow the user to enable or disable the port auto negotiation."
DEFVAL { disable }
::= { esmConfEntry 15 }
esmPortCfgCrossover OBJECT-TYPE
SYNTAX INTEGER {
mdi(1),
mdix(2),
auto(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allow the user to configure port crossover."
DEFVAL { auto }
::= { esmConfEntry 16 }
esmPortCfgFlow OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Use the dot3PauseAdminMode from the standard MIB to configure the flow control."
DEFVAL { disable }
::= { esmConfEntry 17 }
esmPortCfgHybridActiveType OBJECT-TYPE
SYNTAX INTEGER {
notapplicable(0),
fiber(1),
copper(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is only applicable to hybrid ports .
It indicates configured active media type.(the operational media
type may be different if esmPortCfgHybridMode is configured to be
preferredFiber or preferredCopper)
For non hybrid ports notapplicable is returned as a status."
::= { esmConfEntry 18 }
esmPortCfgHybridMode OBJECT-TYPE
SYNTAX INTEGER {
notapplicable(0),
preferredCopper(1),
forcedCopper(2),
preferredFiber(3),
forcedFiber(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is only applicable to hybrid ports.
This allows the user the user to configure the media type
with which the port should come up.
The user can configure the port to come as copper only
or fiber only or either fiber/copper
(with preference to one of them)."
DEFVAL { preferredFiber }
::= { esmConfEntry 19 }
esmPortOperationalHybridType OBJECT-TYPE
SYNTAX INTEGER {
none(0),
fiber(1),
copper(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is only applicable to hybrid ports .
It indicates the actual media type that has link up and is or will be
passing traffic. If link is not present the object will return none(0) value."
::= { esmConfEntry 20 }
esmPortCfgMMULowWaterMarkCellSetLimit OBJECT-TYPE
SYNTAX INTEGER (0..16383)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Per-port-per-CoS Head of Line blocking cell limits. Range is 0 - 16383
Firebolt register Offset: 0x006pp30 - 0x37
Bits: 13:0 CellSetLimit , Default: 0x0100
This setting allocates the guaranteed cells for one port's CoSx queue.
After cell count over this limit, it will start using dynamic cells in
port dynamic space."
DEFVAL { 256 }
::= { esmConfEntry 21 }
esmPortCfgMMUDynamicCellSetLimit OBJECT-TYPE
SYNTAX INTEGER (0..16383)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Per-egress port cell-based dynamic (shared buffer pool) memory
usage drop and resume thresholds. This sets the limit for which
the eight CoS-Qs within a port may share once the LWMCOSCELL
limit is exceeded. Range is 0 - 16383
Firebolt register Offset: 0x006pp040
Bits: 13:0 Dynamic CellSetLimit ,
Chip Default: 0x0400 (1024).
The system default value for Dynamic CellSetLimit is 0x100 (256)."
DEFVAL { 1024 }
::= { esmConfEntry 22 }
esmPortViolationBitMap OBJECT-TYPE
SYNTAX BITS{
bEniSecurityBlockPortENI(0), -- ENI App blocking this port
bEniSecurityBlockPortSTP(1), -- STP App blocking this port
bEniSecurityBlockPortSL(2), -- SL App blocking this port
bEniSecurityBlockPortQoS(3), -- QoS App blocking this port
bEniSecurityBlockPortUDLD(4), -- UDLD App blocking this port
bEniSecurityBlockPortETHBLK(5) -- ETHBLK App blocking this port
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A bit map that identifies the set of Application that have blocked
a port as a result of a particular violation "
::= { esmConfEntry 23 }
esmPortViolationClearAll OBJECT-TYPE
SYNTAX INTEGER(0)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Clear all port vioaltion "
::= { esmConfEntry 24 }
esmPortFloodBcastEnable OBJECT-TYPE
SYNTAX INTEGER {
disableBcastFlood(2),
enableBcastFlood(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the maximum flood rate
for Broadcast."
DEFVAL { enableBcastFlood }
::= { esmConfEntry 25 }
esmPortFloodUnknownUcastEnable OBJECT-TYPE
SYNTAX INTEGER {
disableUnknownUcastFlood(2),
enableUnknownUcastFlood(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the maximum flood rate
for unknown unicast."
DEFVAL { enableUnknownUcastFlood }
::= { esmConfEntry 26 }
esmPortMaxUnknownUcastFloodRate OBJECT-TYPE
SYNTAX INTEGER {
mbps(1),
percentage(2),
pps(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unknown-Unicast flood threshold type. To set the type, set esmPortMaxUnknownUcastFloodRateLimit also"
DEFVAL { mbps }
::= { esmConfEntry 27 }
esmPortMaxMcastFloodRate OBJECT-TYPE
SYNTAX INTEGER {
mbps(1),
percentage(2),
pps(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Multicast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also."
DEFVAL { mbps }
::= { esmConfEntry 28 }
esmPortMaxFloodRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the maximum broadcast flood limit.
The actual range of the flood limit depends on the port speed.
example:
Percentage: 1 - 100
Mbps: 1 - 1000 (1G speed)
PPS: 244 - 244262 (1G speed)
To set the limit, set esmPortMaxFloodRate first"
::= { esmConfEntry 29 }
esmPortMaxUnknownUcastFloodRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the maximum unknown-unicast flood limit
The actual range of the flood limit depends on the port speed.
example:
Percentage: 1 - 100
Mbps: 1 - 1000 (1G speed)
PPS: 244 - 244262 (1G speed)
To set the limit, set esmPortMaxUnknownUcastFloodRate first"
::= { esmConfEntry 30 }
esmPortMaxMcastFloodRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the maximum multicast flood limit
The actual range of the flood limit depends on the port speed.
example:
Percentage: 1 - 100
Mbps: 1 - 1000 (1G speed)
PPS: 244 - 244262 (1G speed)
To set the limit, set esmPortMaxMcastFloodRate first"
::= { esmConfEntry 31 }
esmPortCfgSFPType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is only applicable to fiber ports.
The string indicates the type of SFP/GBIC of active media."
::= { esmConfEntry 32 }
-- Ethernet Port Mode Tables *****************************
-- EsmPortMode group. This group contains the configuration
-- information data for the Ethernet Switching Module.
-- Implementation of this group is mandantory.
--
-- Note that this MIB can NOT be used for row creation (this
-- would imply that you could override the actual physical
-- characteristics of the physical card!).
esmPortModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF EsmPortModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of ESM Physical Port Mode instances."
::= { physicalPort 6 }
esmPortModeEntry OBJECT-TYPE
SYNTAX EsmPortModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A ESM Physical Port Mode entry."
INDEX { esmPortModeIndex }
::= { esmPortModeTable 1 }
EsmPortModeEntry ::= SEQUENCE {
esmPortModeIndex
INTEGER,
esmPortRunningMode
INTEGER,
esmPortSavedMode
INTEGER
}
esmPortModeIndex OBJECT-TYPE
SYNTAX INTEGER (1001..8128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Valid ni/port values"
::= { esmPortModeEntry 1 }
esmPortRunningMode OBJECT-TYPE
SYNTAX INTEGER {
uplink(1),
stackable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Currently configured Etna port 25,26 as 10G uplink user port or stacking port.
Default is uplink 10G port. User can not set the current mode."
::= { esmPortModeEntry 2 }
esmPortSavedMode OBJECT-TYPE
SYNTAX INTEGER {
uplink(1),
stackable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Next configured Etna port 25,26 as 10G uplink user port or stacking port.
At boot up, it has the same value as current esmPortRunningMode. It takes some time to
write to the EEPROM. Have at least more than 7 sec between each write operation"
::= { esmPortModeEntry 3 }
-- The Ethernet Statistics Group
--
-- The ethernet statistics group contains statistics
-- measured by the probe for each monitored interface on
-- this device. These statistics take the form of free
-- running counters that start from zero when a valid entry
-- is created.
--
-- This group currently has statistics defined only for
-- Ethernet interfaces. Each alcetherStatsEntry contains
-- statistics for one Ethernet interface. The probe must
-- create one alcetherStats entry for each monitored Ethernet
-- interface on the device.
alcetherStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlcetherStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Ethernet statistics entries."
::= { physicalPort 2 }
alcetherStatsEntry OBJECT-TYPE
SYNTAX AlcetherStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of statistics kept for a particular
Ethernet interface. As an example, an instance of the
etherStatsPkts object might be named alcetherStatsPkts.1"
INDEX { ifIndex }
::= { alcetherStatsTable 1 }
AlcetherStatsEntry ::= SEQUENCE {
alcetherClearStats INTEGER,
alcetherLastClearStats TimeTicks,
alcetherStatsCRCAlignErrors Counter64,
alcetherStatsRxUndersizePkts Counter64,
alcetherStatsTxUndersizePkts Counter64,
alcetherStatsTxOversizePkts Counter64,
alcetherStatsRxJabbers Counter64,
alcetherStatsRxCollisions Counter64,
alcetherStatsTxCollisions Counter64,
alcetherStatsPkts64Octets Counter64,
alcetherStatsPkts65to127Octets Counter64,
alcetherStatsPkts128to255Octets Counter64,
alcetherStatsPkts256to511Octets Counter64,
alcetherStatsPkts512to1023Octets Counter64,
alcetherStatsPkts1024to1518Octets Counter64,
gigaEtherStatsPkts1519to4095Octets Counter64,
gigaEtherStatsPkts4096to9215Octets Counter64,
alcetherStatsPkts1519to2047Octets Counter64,
alcetherStatsPkts2048to4095Octets Counter64,
alcetherStatsPkts4096Octets Counter64,
alcetherStatsRxGiantPkts Counter64,
alcetherStatsRxDribbleNibblePkts Counter64,
alcetherStatsRxLongEventPkts Counter64,
alcetherStatsRxVlanTagPkts Counter64,
alcetherStatsRxControlPkts Counter64,
alcetherStatsRxLenChkErrPkts Counter64,
alcetherStatsRxCodeErrPkts Counter64,
alcetherStatsRxDvEventPkts Counter64,
alcetherStatsRxPrevPktDropped Counter64,
alcetherStatsTx64Octets Counter64,
alcetherStatsTx65to127Octets Counter64,
alcetherStatsTx128to255Octets Counter64,
alcetherStatsTx256to511Octets Counter64,
alcetherStatsTx512to1023Octets Counter64,
alcetherStatsTx1024to1518Octets Counter64,
alcetherStatsTx1519to2047Octets Counter64,
alcetherStatsTx2048to4095Octets Counter64,
alcetherStatsTx4096Octets Counter64,
alcetherStatsTxRetryCount Counter64,
alcetherStatsTxVlanTagPkts Counter64,
alcetherStatsTxControlPkts Counter64,
alcetherStatsTxLatePkts Counter64,
alcetherStatsTxTotalBytesOnWire Counter64,
alcetherStatsTxLenChkErrPkts Counter64,
alcetherStatsTxExcDeferPkts Counter64
}
alcetherClearStats OBJECT-TYPE
SYNTAX INTEGER
{ default(0),
reset(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to Clear all Statistics counters.
By default, this object contains zero value."
::= { alcetherStatsEntry 1 }
alcetherLastClearStats OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of SysUpTime at the time of all
the statistics counters are cleared.
By default, this object contains a zero value."
::= { alcetherStatsEntry 2 }
alcetherStatsCRCAlignErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that
had a length (excluding framing bits, but
including FCS octets) of between 64 and 1518
octets, inclusive, but but had either a bad
Frame Check Sequence (FCS) with an integral
number of octets (FCS Error) or a bad FCS with
a non-integral number of octets (Alignment Error)."
::= { alcetherStatsEntry 3 }
alcetherStatsRxUndersizePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { alcetherStatsEntry 4 }
alcetherStatsTxUndersizePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { alcetherStatsEntry 5 }
alcetherStatsTxOversizePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted that were
longer than 1518 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { alcetherStatsEntry 6 }
alcetherStatsRxJabbers OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and had either a bad
Frame Check Sequence (FCS) with an integral number
of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error).
Note that this definition of jabber is different
than the definition in IEEE-802.3 section 8.2.1.5
(10BASE5) and section 10.3.1.4 (10BASE2). These
documents define jabber as the condition where any
packet exceeds 20 ms. The allowed range to detect
jabber is between 20 ms and 150 ms."
::= { alcetherStatsEntry 7 }
alcetherStatsRxCollisions OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment (in reception).
Only for Ethernet Interfaces.
The value returned will depend on the location of
the RMON probe. Section 8.2.1.3 (10BASE-5) and
section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
states that a station must detect a collision, in
the receive mode, if three or more stations are
transmitting simultaneously. A repeater port must
detect a collision when two or more stations are
transmitting simultaneously. Thus a probe placed on
a repeater port could record more collisions than a
probe connected to a station on the same segment
would.
Probe location plays a much smaller role when
considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE
standard 802.3 defines a collision as the
simultaneous presence of signals on the DO and RD
circuits (transmitting and receiving at the same
time). A 10BASE-T station can only detect
collisions when it is transmitting. Thus probes
placed on a station and a repeater, should report
the same number of collisions.
Note also that an RMON probe inside a repeater
should ideally report collisions between the
repeater and one or more other hosts (transmit
collisions as defined by IEEE 802.3k) plus receiver
collisions observed on any coax segments to which
the repeater is connected."
::= { alcetherStatsEntry 8 }
alcetherStatsTxCollisions OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment (in transmition).
Only for Ethernet Interfaces.
The value returned will depend on the location of
the RMON probe. Section 8.2.1.3 (10BASE-5) and
section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
states that a station must detect a collision, in
the receive mode, if three or more stations are
transmitting simultaneously. A repeater port must
detect a collision when two or more stations are
transmitting simultaneously. Thus a probe placed on
a repeater port could record more collisions than a
probe connected to a station on the same segment
would.
Probe location plays a much smaller role when
considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE
standard 802.3 defines a collision as the
simultaneous presence of signals on the DO and RD
circuits (transmitting and receiving at the same
time). A 10BASE-T station can only detect
collisions when it is transmitting. Thus probes
placed on a station and a repeater, should report
the same number of collisions.
Note also that an RMON probe inside a repeater
should ideally report collisions between the
repeater and one or more other hosts (transmit
collisions as defined by IEEE 802.3k) plus receiver
collisions observed on any coax segments to which
the repeater is connected."
::= { alcetherStatsEntry 9 }
alcetherStatsPkts64Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were 64 octets in length
(excluding framing bits but including FCS octets)."
::= { alcetherStatsEntry 10 }
alcetherStatsPkts65to127Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { alcetherStatsEntry 11 }
alcetherStatsPkts128to255Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { alcetherStatsEntry 12 }
alcetherStatsPkts256to511Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { alcetherStatsEntry 13 }
alcetherStatsPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { alcetherStatsEntry 14 }
alcetherStatsPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets).
For both Ethernet and GigaEthernet."
::= { alcetherStatsEntry 15 }
gigaEtherStatsPkts1519to4095Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
1519 and 4095 octets in length inclusive
(excluding framing bits but including FCS octets).
Only for GigaEthernet interfaces"
::= { alcetherStatsEntry 16 }
gigaEtherStatsPkts4096to9215Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
4096 and 9215 octets in length inclusive
(excluding framing bits but including FCS octets).
Only for GigaEthernet interfaces"
::= { alcetherStatsEntry 17 }
alcetherStatsPkts1519to2047Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames(including error packets) received
that were between 1519 and 2047 bytes in length inclusive
(excluding framing bits but including FCS bytes).
"
::= { alcetherStatsEntry 18 }
alcetherStatsPkts2048to4095Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames(including error packets) received
that were between 2048 and 4095 bytes in length inclusive
(excluding framing bits but including FCS bytes).
"
::= { alcetherStatsEntry 19 }
alcetherStatsPkts4096Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames(including error packets) received
that were greater than or equal to 4096 bytes in length inclusive
(excluding framing bits but including FCS bytes).
"
::= { alcetherStatsEntry 20 }
alcetherStatsRxGiantPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames that are greater than the specified
Max length value, with a valid CRC, dropped because too long.
"
::= { alcetherStatsEntry 21 }
alcetherStatsRxDribbleNibblePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames for which a dribble nibble has been
received and CRC is correct.
"
::= { alcetherStatsEntry 22 }
alcetherStatsRxLongEventPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames for which the Carrier sense exceeds
50000 bit times for 10 Mbits/sec or 80000 bit times for
100 Mbits/sec."
::= { alcetherStatsEntry 23 }
alcetherStatsRxVlanTagPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames for which Type/Length field
contains the VLAN protocol identifier (0x8100). "
::= { alcetherStatsEntry 24 }
alcetherStatsRxControlPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames that were recognized as control frames."
::= { alcetherStatsEntry 25 }
alcetherStatsRxLenChkErrPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames for which the frame length field value
in the Type/Length field does not match the actual data bytes
length and is NOT a type field."
::= { alcetherStatsEntry 26 }
alcetherStatsRxCodeErrPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames for which one or more nibbles were
signaled as errors during reception of the frame."
::= { alcetherStatsEntry 27 }
alcetherStatsRxDvEventPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames for which a RX_DV event (packet not
too long enough to be valid packet) has been seen before the
correct frame."
::= { alcetherStatsEntry 28 }
alcetherStatsRxPrevPktDropped OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames for which a packet has been dropped
(because of too small IFG) before the correct frame."
::= { alcetherStatsEntry 29 }
alcetherStatsTx64Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames of 64 bytes."
::= { alcetherStatsEntry 30 }
alcetherStatsTx65to127Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were between
65 and 127 bytes in length inclusive (excluding framing bits
but including FCS bytes)."
::= { alcetherStatsEntry 31 }
alcetherStatsTx128to255Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were between
128 and 255 bytes in length inclusive (excluding framing bits
but including FCS bytes)."
::= { alcetherStatsEntry 32 }
alcetherStatsTx256to511Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were between
256 and 511 bytes in length inclusive (excluding framing bits
but including FCS bytes)."
::= { alcetherStatsEntry 33 }
alcetherStatsTx512to1023Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were between
512 and 1023 bytes in length inclusive (excluding framing bits
but including FCS bytes)."
::= { alcetherStatsEntry 34 }
alcetherStatsTx1024to1518Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were between
1024 and 1518 bytes in length inclusive (excluding framing bits
but including FCS bytes)."
::= { alcetherStatsEntry 35 }
alcetherStatsTx1519to2047Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were between
1519 and 2047 bytes in length inclusive (excluding framing bits
but including FCS bytes)."
::= { alcetherStatsEntry 36 }
alcetherStatsTx2048to4095Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were between
2048 and 4095 bytes in length inclusive (excluding framing bits
but including FCS bytes)."
::= { alcetherStatsEntry 37 }
alcetherStatsTx4096Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were greater than
or equal to 4096 bytes in length and less than Max frame length
(excluding framing bits but including FCS bytes)."
::= { alcetherStatsEntry 38 }
alcetherStatsTxRetryCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of collisions that the frames faced during
transmission attempts."
::= { alcetherStatsEntry 39 }
alcetherStatsTxVlanTagPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames for which Type/Length field contains the
VLAN protocol identifier (0x8100)."
::= { alcetherStatsEntry 40 }
alcetherStatsTxControlPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames that were recognised as control frames."
::= { alcetherStatsEntry 41 }
alcetherStatsTxLatePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of late collisions that occured beyond the collision window."
::= { alcetherStatsEntry 42 }
alcetherStatsTxTotalBytesOnWire OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes transmitted on wire, including all bytes from collided
attempts."
::= { alcetherStatsEntry 43 }
alcetherStatsTxLenChkErrPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted frames for which the frame length field value
in the Type/Length field does not match the actual data bytes length and
is NOT a Type field."
::= { alcetherStatsEntry 44 }
alcetherStatsTxExcDeferPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames that were deferred in excess of 6071 nibble-times
in 100 Mbps, 24287 bit-times in 10 Mbps mode. These frames are dropped.(This
stat is only in case of Half duplex and excessive defer bit reset)."
::= { alcetherStatsEntry 45 }
-- 10 GIG specifics parameters
alcether10GigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Alcether10GigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of 10 Gig specifics entries."
::= { physicalPort 4 }
alcether10GigEntry OBJECT-TYPE
SYNTAX Alcether10GigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table will be populated with the 10 gig only entries.
The management interface can use it to specify if A or B is the primary."
INDEX { ifIndex }
::= { alcether10GigTable 1 }
Alcether10GigEntry ::= SEQUENCE {
alcether10GigPrimary INTEGER
}
alcether10GigPrimary OBJECT-TYPE
SYNTAX INTEGER
{ phyAprimary(1),
phyBprimary(2),
notApplicable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the object to 1 will make phy A as primary, 2- phy B as pirmary.
Value 3 should not be set. "
::= { alcether10GigEntry 1 }
-- End of 10 GIG specifics parameters
-- Ethernet Driver Tables *****************************
-- EsmHybridConf table contains the configuration
-- information about the configured inactive media for the
-- hybrid port only.
-- Implementation of this group is mandantory.
--
-- Note that entries in this MIB Table can NOT be created by the user, only modified
esmHybridConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF EsmHybridConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of inactive hybrid port instances."
::= { physicalPort 3 }
esmHybridConfEntry OBJECT-TYPE
SYNTAX EsmHybridConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A ESM Physical Port entry."
INDEX { ifIndex }
::= { esmHybridConfTable 1 }
EsmHybridConfEntry ::= SEQUENCE {
esmHybridPortCfgSpeed
INTEGER,
esmHybridPortCfgDuplexMode
INTEGER,
esmHybridPortCfgAutoNegotiation
INTEGER,
esmHybridPortCfgCrossover
INTEGER,
esmHybridPortCfgFlow
INTEGER,
esmHybridPortCfgInactiveType
INTEGER,
esmHybridPortCfgSFPType
DisplayString
}
esmHybridPortCfgSpeed OBJECT-TYPE
SYNTAX INTEGER {
speed100(1),
speed10(2),
speedAuto(3),
speed1000(5),
speed10000(6),
speedMax100(8),
speedMax1000(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured port line speed of this ESM port."
::= { esmHybridConfEntry 1 }
esmHybridPortCfgDuplexMode OBJECT-TYPE
SYNTAX INTEGER {
fullDuplex(1),
halfDuplex(2),
autoDuplex(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured port duplex mode of this ESM port.
Note: GigaEthernet support only full-duplex."
::= { esmHybridConfEntry 2 }
esmHybridPortCfgAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allow the user to enable or disable the port auto negotiation."
DEFVAL { disable }
::= { esmHybridConfEntry 3 }
esmHybridPortCfgCrossover OBJECT-TYPE
SYNTAX INTEGER {
mdi(1),
mdix(2),
auto(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allow the user to configure port crossover."
DEFVAL { auto }
::= { esmHybridConfEntry 4 }
esmHybridPortCfgFlow OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enabledXmit(2),
enabledRcv(3),
enabledXmitAndRcv(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for flow control of hybrid ports. It is similar to the dot3PauseAdminMode
object in dot3PauseTable. It is used to configure pause for fiber media."
DEFVAL { disable }
::= { esmHybridConfEntry 5 }
esmHybridPortCfgInactiveType OBJECT-TYPE
SYNTAX INTEGER {
fiber(1),
copper(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is only applicable to hybrid ports .
It indicates the configured inactive media type."
::= { esmHybridConfEntry 6 }
esmHybridPortCfgSFPType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is only applicable to fiber ports.
The string indicates the type of SFP/GBIC of active media."
::= { esmHybridConfEntry 7 }
-- End-to-End Flow Vlan Configuration *****************
esmE2EFlowVlan OBJECT-TYPE
SYNTAX INTEGER (0 .. 4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"0 - Deleting End-to-End flow control
1-4094 - Enable End-to-End flow control and use the Vlan configured as for End-to-End flow"
::= { alcatelIND1PortMIBObjects 3 }
-- Digital Diagnostics Monitoring (DDM) **************************
ddmConfig OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables DDM software feature in the system."
DEFVAL { disable }
::= { ddmConfiguration 1 }
ddmTrapConfig OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects enables/disables traps for DDM warning/alarm threshold violations."
DEFVAL { disable }
::= { ddmConfiguration 2 }
ddmNotificationType OBJECT-TYPE
SYNTAX INTEGER
{
clearViolation(1),
highAlarm(2),
highWarning(3),
lowWarning(4),
lowAlarm(5)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object defines the trap type for monitored DDM parameters."
::= { ddmConfiguration 3 }
-- esmViolationRecoveryTime Configuration *****************
esmViolationRecoveryTrap OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects enables/disables traps for user-port shutdown"
DEFVAL { disable }
::= { esmViolationRecovery 1 }
esmViolationRecoveryTime OBJECT-TYPE
SYNTAX INTEGER (0 .. 600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"0 - Disable the timer
30 - 600 - timeout value to re-enable the UserPort ports"
::= { esmViolationRecovery 2 }
esmViolationRecoveryNotificationType OBJECT-TYPE
SYNTAX INTEGER
{
clearViolation(1)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object defines the trap type for monitored violation-recovery parameters."
::= { esmViolationRecovery 3 }
ddmInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF DdmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ddmInfoTable has an entry for each SFP/XFP in the
system that supports Digital Diagnostic Monitoring (DDM). The table is
indexed by ifIndex. Each row in this table is dynamically added
and removed internally by the system based on the presence or absence
of DDM capable SFP/XFP components."
::= { physicalPort 5 }
ddmInfoEntry OBJECT-TYPE
SYNTAX DdmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row represents a particular SFP/XFP that supports Digital
Diagnostic Monitoring.
Entries are created and deleted internally by the system."
INDEX { ifIndex }
::= { ddmInfoTable 1}
DdmEntry ::= SEQUENCE
{
ddmTemperature Integer32,
ddmTempLowWarning Integer32,
ddmTempLowAlarm Integer32,
ddmTempHiWarning Integer32,
ddmTempHiAlarm Integer32,
ddmSupplyVoltage Integer32,
ddmSupplyVoltageLowWarning Integer32,
ddmSupplyVoltageLowAlarm Integer32,
ddmSupplyVoltageHiWarning Integer32,
ddmSupplyVoltageHiAlarm Integer32,
ddmTxBiasCurrent Integer32,
ddmTxBiasCurrentLowWarning Integer32,
ddmTxBiasCurrentLowAlarm Integer32,
ddmTxBiasCurrentHiWarning Integer32,
ddmTxBiasCurrentHiAlarm Integer32,
ddmTxOutputPower Integer32,
ddmTxOutputPowerLowWarning Integer32,
ddmTxOutputPowerLowAlarm Integer32,
ddmTxOutputPowerHiWarning Integer32,
ddmTxOutputPowerHiAlarm Integer32,
ddmRxOpticalPower Integer32,
ddmRxOpticalPowerLowWarning Integer32,
ddmRxOpticalPowerLowAlarm Integer32,
ddmRxOpticalPowerHiWarning Integer32,
ddmRxOpticalPowerHiAlarm Integer32
}
ddmTemperature OBJECT-TYPE
SYNTAX Integer32 (-200000 | -150000..150000)
UNITS "thousandth of a degree celcius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTemperature indicates the current temperature
of the SFP/XFP in 1000s of degrees Celsius.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 1 }
ddmTempLowWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | -150000..150000)
UNITS "thousandth of a degree celcius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTempLowWarning indicates the temperature
of the SFP/XFP in 1000s of degrees Celsius that triggers a low-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 2 }
ddmTempLowAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | -150000..150000)
UNITS "thousandth of a degree celcius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTempLowAlarm indicates the temperature
of the SFP/XFP in 1000s of degrees Celsius that triggers a low-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 3 }
ddmTempHiWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | -150000..150000)
UNITS "thousandth of a degree celcius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTempHiWarning indicates the temperature
of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 4 }
ddmTempHiAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | -150000..150000)
UNITS "thousandth of a degree celcius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTempHiAlarm indicates the temperature
of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 5 }
ddmSupplyVoltage OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmSupplyVoltage indicates the current supply
voltage of the SFP/XFP in 1000s of Volts (V).
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 6 }
ddmSupplyVoltageLowWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmSupplyVoltageLowWarning indicates the supply
voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 7 }
ddmSupplyVoltageLowAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmSupplyVoltageLowAlarm indicates the supply
voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 8 }
ddmSupplyVoltageHiWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmSupplyVoltageHiWarning indicates the supply
voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 9 }
ddmSupplyVoltageHiAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmSupplyVoltageHiAlarm indicates the supply
voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 10 }
ddmTxBiasCurrent OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a milli-Ampere"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxBiasCurrent indicates the current Transmit
Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA).
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 11 }
ddmTxBiasCurrentLowWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a milli-Ampere"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxBiasCurrentLowWarning indicates the Transmit
Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a
low-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 12 }
ddmTxBiasCurrentLowAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a milli-Ampere"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxBiasCurrentLowAlarm indicates the Transmit
Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a
low-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 13 }
ddmTxBiasCurrentHiWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a milli-Ampere"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxBiasCurrentHiWarning indicates the Transmit
Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a
hi-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 14 }
ddmTxBiasCurrentHiAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | 0..10000)
UNITS "thousandth of a milli-Ampere"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxBiasCurrentHiAlarm indicates the Transmit
Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a
hi-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 15 }
ddmTxOutputPower OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxOutputPower indicates the current Output
Power of the SFP/XFP in 1000s of dBm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 16 }
ddmTxOutputPowerLowWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxOutputPowerLowWarning indicates the Output Power
of the SFP/XFP in 1000s of dBm that triggers a low-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 17 }
ddmTxOutputPowerLowAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxOutputPowerLowAlarm indicates the Output Power
of the SFP/XFP in 1000s of dBm that triggers a low-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 18 }
ddmTxOutputPowerHiWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxOutputPowerHiWarning indicates the Output Power
of the SFP/XFP in 1000s of dBm that triggers a hi-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 19 }
ddmTxOutputPowerHiAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmTxOutputPowerHiAlarm indicates the Output Power
of the SFP/XFP in 1000s of dBm that triggers a hi-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 20 }
ddmRxOpticalPower OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmRxOpticalPower indicates the current Received
Optical Power of the SFP/XFP in 1000s of dBm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 21 }
ddmRxOpticalPowerLowWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmRxOpticalPowerLowWarning indicates the Received
Optical Power of the SFP/XFP in 1000s of dBm that triggers a
low-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 22 }
ddmRxOpticalPowerLowAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmRxOpticalPowerLowAlarm indicates the Received
Optical Power of the SFP/XFP in 1000s of dBm that triggers a
low-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 23 }
ddmRxOpticalPowerHiWarning OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmRxOpticalPowerHiWarning indicates the Received
Optical Power of the SFP/XFP in 1000s of dBm that triggers a
hi-warning.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 24 }
ddmRxOpticalPowerHiAlarm OBJECT-TYPE
SYNTAX Integer32 (-200000 | -40000..10000)
UNITS "thousandth of a dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ddmRxOpticalPowerHiAlarm indicates the Received
Optical Power of the SFP/XFP in 1000s of dBm that triggers a
hi-alarm.
A value of -200000 indicates this object is not applicable."
::= { ddmInfoEntry 25 }
-- Ethernet Driver Trap *********************
esmDrvTrapDropsLink NOTIFICATION-TYPE
OBJECTS {
esmPortSlot,
esmPortIF,
ifInErrors,
ifOutErrors,
esmDrvTrapDrops
}
STATUS current
DESCRIPTION
"When the Ethernet code drops the link because of
excessive errors, a Trap is sent."
::= { cmmEsmDrvTraps 0 1 }
e2eStackTopoChangeTrap NOTIFICATION-TYPE
OBJECTS {
esmE2EFlowVlan
}
STATUS current
DESCRIPTION
"Trap Generated when Stack Topology changes."
::= { cmmEsmDrvTraps 0 2 }
ddmTemperatureThresholdViolated NOTIFICATION-TYPE
OBJECTS {
ifIndex,
ddmNotificationType,
ddmTemperature
}
STATUS current
DESCRIPTION
"This object notifies management station if an SFP/XFP/SFP+ temperature has crossed any
threshold or reverted from previous threshold violation for a port represented by ifIndex.
It also provides the current realtime value of SFP/XFP/SFP+ temperature."
::= { ddmNotifications 0 1 }
ddmVoltageThresholdViolated NOTIFICATION-TYPE
OBJECTS {
ifIndex,
ddmNotificationType,
ddmSupplyVoltage
}
STATUS current
DESCRIPTION
"This object notifies management station if an SFP/XFP/SFP+ supply voltage has crossed any
threshold or reverted from previous threshold violation for a port represented by ifIndex.
It also provides the current realtime value of SFP/XFP/SFP+ supply voltage."
::= { ddmNotifications 0 2 }
ddmCurrentThresholdViolated NOTIFICATION-TYPE
OBJECTS {
ifIndex,
ddmNotificationType,
ddmTxBiasCurrent
}
STATUS current
DESCRIPTION
"This object notifies management station if an SFP/XFP/SFP+ Tx bias current has crossed any
threshold or reverted from previous threshold violation for a port represented by ifIndex.
It also provides the current realtime value of SFP/XFP/SFP+ Tx bias current."
::= { ddmNotifications 0 3 }
ddmTxPowerThresholdViolated NOTIFICATION-TYPE
OBJECTS {
ifIndex,
ddmNotificationType,
ddmTxOutputPower
}
STATUS current
DESCRIPTION
"This object notifies management station if an SFP/XFP/SFP+ Tx output power has crossed any
threshold or reverted from previous threshold violation for a port represented by ifIndex.
It also provides the current realtime value of SFP/XFP/SFP+ Tx output power."
::= { ddmNotifications 0 4 }
ddmRxPowerThresholdViolated NOTIFICATION-TYPE
OBJECTS {
ifIndex,
ddmNotificationType,
ddmRxOpticalPower
}
STATUS current
DESCRIPTION
"This object notifies management station if an SFP/XFP/SFP+ Rx optical power has crossed any
threshold or reverted from previous threshold violation for a port represented by ifIndex.
It also provides the current realtime value of SFP/XFP/SFP+ Rx optical power."
::= { ddmNotifications 0 5 }
esmViolationRecoveryTimeout NOTIFICATION-TYPE
OBJECTS {
ifIndex,
esmViolationRecoveryNotificationType
}
STATUS current
DESCRIPTION
"This object notifies management station if User-Port ports get re-enabled after esm violation recovery time"
::= { esmViolationNotifications 0 1 }
-- conformance information
alcatelIND1PortMIBCompliances OBJECT IDENTIFIER ::= { alcatelIND1PortMIBConformance 1 }
alcatelIND1PortMIBGroups OBJECT IDENTIFIER ::= { alcatelIND1PortMIBConformance 2 }
-- compliance statements
esmConfPortCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the configuration of Ethernet
ports."
MODULE -- this module
MANDATORY-GROUPS { esmConfMIBGroup,
esmDetectedConfMIBGroup,
esmPortModeMIBGroup,
ddmInfoGroup,
ddmConfigGroup,
ddmNotificationsGroup,
violationRecoveryGroup,
violationNotificationsGroup
}
::= { alcatelIND1PortMIBCompliances 1 }
alcEtherStatsCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Statistics of the Ethernet
ports."
MODULE -- this module
MANDATORY-GROUPS { alcEtherStatsMIBGroup }
::= { alcatelIND1PortMIBCompliances 2 }
-- units of conformance
esmConfMIBGroup OBJECT-GROUP
OBJECTS { esmPortCfgSpeed,
esmPortCfgDuplexMode, esmPortCfgIFG,
esmPortPauseSlotTime, esmPortMaxFloodRate,
esmPortFloodMcastEnable, esmPortCfgMaxFrameSize, esmPortCfgAutoNegotiation,
esmPortCfgCrossover, esmPortCfgFlow, esmPortFloodUnknownUcastEnable,
esmPortMaxUnknownUcastFloodRate,esmPortMaxMcastFloodRate,esmPortFloodBcastEnable,
esmPortMaxFloodRateLimit,esmPortMaxUnknownUcastFloodRateLimit,esmPortMaxMcastFloodRateLimit, esmPortCfgSFPType
}
STATUS current
DESCRIPTION
"A collection of objects to support the management of global
configuration parameters of the Ethernet ports."
::= { alcatelIND1PortMIBGroups 1 }
esmDetectedConfMIBGroup OBJECT-GROUP
OBJECTS { esmPortAutoSpeed, esmPortAutoDuplexMode
}
STATUS current
DESCRIPTION
"A collection of objects to support the Detected
configuration parameters of the Ethernet ports."
::= { alcatelIND1PortMIBGroups 2 }
alcEtherStatsMIBGroup OBJECT-GROUP
OBJECTS { alcetherClearStats, alcetherLastClearStats,
alcetherStatsCRCAlignErrors, alcetherStatsRxUndersizePkts,
alcetherStatsTxUndersizePkts, alcetherStatsTxOversizePkts,
alcetherStatsRxJabbers, alcetherStatsRxCollisions,
alcetherStatsTxCollisions, alcetherStatsPkts64Octets,
alcetherStatsPkts65to127Octets, alcetherStatsPkts128to255Octets,
alcetherStatsPkts256to511Octets,
alcetherStatsPkts512to1023Octets,
alcetherStatsPkts1024to1518Octets,
gigaEtherStatsPkts1519to4095Octets,
gigaEtherStatsPkts4096to9215Octets,
alcetherStatsPkts1519to2047Octets,
alcetherStatsPkts2048to4095Octets,
alcetherStatsPkts4096Octets,
alcetherStatsRxGiantPkts,
alcetherStatsRxDribbleNibblePkts,
alcetherStatsRxLongEventPkts,
alcetherStatsRxVlanTagPkts,
alcetherStatsRxControlPkts,
alcetherStatsRxLenChkErrPkts,
alcetherStatsRxCodeErrPkts,
alcetherStatsRxDvEventPkts,
alcetherStatsRxPrevPktDropped,
alcetherStatsTx64Octets,
alcetherStatsTx65to127Octets,
alcetherStatsTx128to255Octets,
alcetherStatsTx256to511Octets,
alcetherStatsTx512to1023Octets,
alcetherStatsTx1024to1518Octets,
alcetherStatsTx1519to2047Octets,
alcetherStatsTx2048to4095Octets,
alcetherStatsTx4096Octets,
alcetherStatsTxRetryCount,
alcetherStatsTxVlanTagPkts,
alcetherStatsTxControlPkts,
alcetherStatsTxLatePkts,
alcetherStatsTxTotalBytesOnWire,
alcetherStatsTxLenChkErrPkts,
alcetherStatsTxExcDeferPkts
}
STATUS current
DESCRIPTION
"A collection of objects to provide all the statistics related
to the Ethernet and GigaEthernert ports."
::= { alcatelIND1PortMIBGroups 3 }
alcPortNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
esmDrvTrapDropsLink
}
STATUS current
DESCRIPTION
"The Port MIB Notification Group."
::= { alcatelIND1PortMIBGroups 4 }
esmPortModeMIBGroup OBJECT-GROUP
OBJECTS { esmPortRunningMode,
esmPortSavedMode
}
STATUS current
DESCRIPTION
"A collection of objects to support the management of global
configuration parameters of the stacking ports."
::= { alcatelIND1PortMIBGroups 5 }
ddmInfoGroup OBJECT-GROUP
OBJECTS {
ddmTemperature,
ddmTempLowWarning,
ddmTempLowAlarm,
ddmTempHiWarning,
ddmTempHiAlarm,
ddmSupplyVoltage,
ddmSupplyVoltageLowWarning,
ddmSupplyVoltageLowAlarm,
ddmSupplyVoltageHiWarning,
ddmSupplyVoltageHiAlarm,
ddmTxBiasCurrent,
ddmTxBiasCurrentLowWarning,
ddmTxBiasCurrentLowAlarm,
ddmTxBiasCurrentHiWarning,
ddmTxBiasCurrentHiAlarm,
ddmTxOutputPower,
ddmTxOutputPowerLowWarning,
ddmTxOutputPowerLowAlarm,
ddmTxOutputPowerHiWarning,
ddmTxOutputPowerHiAlarm,
ddmRxOpticalPower,
ddmRxOpticalPowerLowWarning,
ddmRxOpticalPowerLowAlarm,
ddmRxOpticalPowerHiWarning,
ddmRxOpticalPowerHiAlarm
}
STATUS current
DESCRIPTION
"A collection of objects to provide digital diagnostics information
related to SFPs, XFPs, and SFP+s."
::= { alcatelIND1PortMIBGroups 6 }
ddmConfigGroup OBJECT-GROUP
OBJECTS {
ddmConfig,
ddmTrapConfig
}
STATUS current
DESCRIPTION
"A collection of objects to allow configuration of DDM and DDM traps."
::= { alcatelIND1PortMIBGroups 7 }
ddmNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
ddmTemperatureThresholdViolated,
ddmVoltageThresholdViolated,
ddmCurrentThresholdViolated,
ddmTxPowerThresholdViolated,
ddmRxPowerThresholdViolated
}
STATUS current
DESCRIPTION
"A collection of notifications used to indicate DDM threshold violations."
::= { alcatelIND1PortMIBGroups 8 }
violationRecoveryGroup OBJECT-GROUP
OBJECTS {
esmViolationRecoveryTrap,
esmViolationRecoveryTime
}
STATUS current
DESCRIPTION
"A collection of objects to allow configuration of violationRecovery."
::= { alcatelIND1PortMIBGroups 9 }
violationNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
esmViolationRecoveryTimeout
}
STATUS current
DESCRIPTION
"A collection of notifications used to indicate esm violation recovery timeout."
::= { alcatelIND1PortMIBGroups 10 }
END
|