1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
|
-- *****************************************************************
-- SONET MIB
-- *****************************************************************
SL-SONET-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, Counter64,
Gauge32 FROM SNMPv2-SMI
DisplayString, TruthValue, RowStatus
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
InterfaceIndex, ifIndex FROM IF-MIB
PerfCurrentCount, PerfIntervalCount,
PerfTotalCount FROM PerfHist-TC-MIB
sitelight FROM SL-NE-MIB;
slSonetMib MODULE-IDENTITY
LAST-UPDATED "200008280000Z"
ORGANIZATION "PacketLight Networks Ltd."
CONTACT-INFO
"Omri_Viner@PacketLight.com"
DESCRIPTION
"This MIB module describes the SiteLight SONET Service.
The mib contains the extensions required for the rfc2558."
::= { sitelight 6 }
SignalLabel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"STS path signal label -- one byte, C2, class A, is allocated to
indicate the construction of the STS SPE.
The following hex values of the C2 byte has been defined."
SYNTAX INTEGER {
sigUnequipped(0), -- Unequipped signal (no path originate equipment)
sigEquipped(1), -- Equipped signal (standard payload)
sigPathFloatVt(2), -- Floating VT mode
sigPathLoackedVt(3), -- Locked VT mode
sigPathAsynchDs3(4), -- Asynchronous mapping for DS3
sigPathSyntran(5), -- Mapping byte observable SYNTRAN
sigPathAsyncDs4na(18), -- Asynchronous mapping for 139.264 Mbps
sigPathAtm(19), -- Mapping for ATM
sigPathDqdb(20), -- Mapping for DQDB
sigPathFddi(21), -- Asynchronous mapping for FDDI
sigPathHdlc(22), -- HDLC-Over-SONET Mapping
sigPathGfp(27) -- GFP Mapping
}
slSonetConfig OBJECT IDENTIFIER ::= { slSonetMib 1}
slSonetOh OBJECT IDENTIFIER ::= { slSonetMib 2 }
-- slSonetPmMib OBJECT IDENTIFIER ::= {slSonetMib 3}
-- slSonetAlarmsMib OBJECT IDENTIFIER ::= {slSonetMib 4}
-- slSonetApsMib OBJECT IDENTIFIER ::= {slSonetMib 5}
slSonetPos OBJECT IDENTIFIER ::= { slSonetMib 6 }
slSonetAls OBJECT IDENTIFIER ::= { slSonetMib 7 }
slSonetFs OBJECT IDENTIFIER ::= { slSonetMib 8 }
slSonetTraps OBJECT IDENTIFIER ::= { slSonetMib 11 }
slSonetOhTrace OBJECT IDENTIFIER ::= {slSonetOh 1} -- Trace Message
slSonetOhSl OBJECT IDENTIFIER ::= {slSonetOh 2} -- Signal Label
slSonetOhTraps OBJECT IDENTIFIER ::= {slSonetOh 3} -- Mismatch Traps
------------------------------
--
-- Sonet Config table
--
------------------------------
slSonetConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH configuration table. This table has objects
for configuring sonet lines."
::= { slSonetConfig 1 }
slSonetConfigEntry OBJECT-TYPE
SYNTAX SlSonetConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table. There is an entry for each SONET line
in the table. Entries are automatically created for an
ifType value of sonet(39). 'ifAdminStatus' from the ifTable
must be used to enable or disable a line. By default, the
line state is down."
INDEX { ifIndex }
::= { slSonetConfigTable 1 }
SlSonetConfigEntry ::=
SEQUENCE {
slSonetConfigFrameScramble INTEGER,
slSonetConfigType INTEGER, -- deprecated
slSonetConfigDccSelection INTEGER,
slSonetResetAllCounters INTEGER,
slSonetPortThresholdTrapEnable INTEGER,
slSonetConfigSdThreshold INTEGER,
slSonetConfigSfThreshold INTEGER,
slSonetCompression INTEGER,
slSonetOverheadTunneling INTEGER,
slSonetLopBitmask Counter64, -- deprecated
slSonetTdmTrunk TruthValue,
slSonetFsApply INTEGER, -- deprecated
slSonetTxLte INTEGER,
slSonetReceivedLte INTEGER,
slSonetResetPmThreshold INTEGER,
slSonetResetAlsParams INTEGER,
slSonetTransceiverType INTEGER,
slSonetTransceiverMedia INTEGER
}
slSonetConfigFrameScramble OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to disable or enable the Scrambling
option in SONET line. Please refer to GR-253-CORE for
frame scrambling."
REFERENCE
"GR-253-CORE"
DEFVAL { enabled }
::= {slSonetConfigEntry 1}
slSonetConfigType OBJECT-TYPE
SYNTAX INTEGER {
sonetSts3(1), -- deprecated
sonetSts3c(2), -- deprecated
sonetSts12(3), -- deprecated
sonetSts12c(4), -- deprecated
sonetSts48c(5),
sonetSts3cx4(6), -- deprecated
sonetSts48(7), -- deprecated
sonetSts3cx16(8), -- deprecated
sonetSts3x16(9), -- deprecated
sonetSts12cx4(10), -- deprecated
sonetSts12x4(11), -- deprecated
sonetSts192c(12),
sonetStsOther(13)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the configured line type for Trunks:
sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk)
sonetSts192c(12) - 1 x Sts192 (10Gb Trunk)
sonetStsOther(13) - for OC-n interfaces see slSonetFsTable."
::= {slSonetConfigEntry 2}
slSonetConfigDccSelection OBJECT-TYPE
SYNTAX INTEGER {
sonetLineDcc(1),
sonetSectionDcc(2),
sonetInband(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the DCC type."
::= {slSonetConfigEntry 3 }
slSonetResetAllCounters OBJECT-TYPE
SYNTAX INTEGER {
resetCounters(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this variable to 1 will cause all of the counters
(performance regsters) on this SONET interface to be initialized
to zero (0)."
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
::= { slSonetConfigEntry 4 }
slSonetPortThresholdTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether threshold traps
should be generated for this SONET interface."
REFERENCE "ANSI T1.231-1997 clause 9.1.5.2."
DEFVAL { disabled }
::= { slSonetConfigEntry 5 }
slSonetConfigSdThreshold OBJECT-TYPE
SYNTAX INTEGER (5..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the Bit Error Rate threshold for
Signal Degrade detection on the working line. Once this
threshold is exceeded, an APS switch will occur.
This value is 10 to -n where n is between 5 and 9
(read-write)."
DEFVAL {5}
::= { slSonetConfigEntry 6 }
slSonetConfigSfThreshold OBJECT-TYPE
SYNTAX INTEGER (3..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the Bit Error Rate threshold for
Signal Fault detection on the working line. Once this
threshold is exceeded, an APS switch will occur.
This value is 10 to the -n, where n is between 3 and 5.
(read-write)"
DEFVAL {3}
::= { slSonetConfigEntry 7 }
slSonetCompression OBJECT-TYPE
SYNTAX INTEGER {
uncompress(0),
posCompress32(1),
posCompress16(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object applies only for trunk ports.
It specifies if the packets should be compressed.
0 - Means no POS compression,
1 - Means POS compression with CRC-32.
2 - Means POS compression with CRC-16.
Note that the two connected trunks should be configured
to the same value.
Note also that the BW calculation of the OC-n should
be changed according to this value."
::= { slSonetConfigEntry 9 }
slSonetOverheadTunneling OBJECT-TYPE
SYNTAX INTEGER {
none(0),
lineDcc(1),
k1k2(2),
full(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The section and line overhead tunneling configuration:
none(0) - no tunneling support
lineDcc(1) - line DCC tunneling
k1k2(2) - line DCC + protection k byte
full(3) - all transport overhead bytes are tunneled"
::= { slSonetConfigEntry 10 }
slSonetLopBitmask OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current -- deprecated
DESCRIPTION
"The LOP status. Each bit of the bits represent the status
of the LOP alarm in corresponding STS.
For a path with more than a single STS, only the value of the
first STS in the path is relevant.
This object is relevant only for the OC-N cards and not
for the Trunk.
In the next future this object will be replaced with
an object of a new table that shall describe the OC-N
frame structure."
::= { slSonetConfigEntry 11 }
slSonetTdmTrunk OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only to the OC-n ports.
TRUE - means that the OC-n port is used as a TDM Trunk.
FLASE - means normal OC-n port."
::= { slSonetConfigEntry 12 }
slSonetFsApply OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write -- deprecated
STATUS current
DESCRIPTION
"Writing to this object activate the slSonetFsTable setting.
This allow the NMS to do many changes to the slSonetFsTable
and then APPLY them at once. This prevent from going through
unconsistent steps.
This object always returns the value 0."
::= { slSonetConfigEntry 13 }
slSonetTxLte OBJECT-TYPE
SYNTAX INTEGER {
ssb00(1), -- SONET
ssb10(2), -- SDH
auto(5) -- Tx what is detected
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SS bits to transmit (bits 5,6 in H1,H1*)."
::= { slSonetConfigEntry 14 }
slSonetReceivedLte OBJECT-TYPE
SYNTAX INTEGER {
ssb00(1), -- SONET
ssb10(2), -- SDH
ssb01(3), -- other
ssb11(4), -- other
ssbinv(5) -- invalid
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detected LTE type, according to the received SS bits
(bits 5,6 in H1,H1*)."
::= { slSonetConfigEntry 15 }
slSonetResetPmThreshold OBJECT-TYPE
SYNTAX INTEGER {
resetCounters(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this variable to 1 will reset the PM threshold
parameters to the factory defaults."
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
::= { slSonetConfigEntry 16 }
slSonetResetAlsParams OBJECT-TYPE
SYNTAX INTEGER {
resetCounters(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this variable to 1 will reset the ALS
parameters to the factory defaults."
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
::= { slSonetConfigEntry 17 }
slSonetTransceiverType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
shortWave(2), -- 850nm
longWave(3) -- 1310nm
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tranceiver type."
::= { slSonetConfigEntry 18 }
slSonetTransceiverMedia OBJECT-TYPE
SYNTAX INTEGER {
none(1), --
sm(2), -- Single Mode
mm(3) -- Multi Mode
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tranceiver media."
::= { slSonetConfigEntry 19 }
-- ----------------------------------------------------------------
--
-- Sonet Trace Table
--
-- ----------------------------------------------------------------
slSonetTraceTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetTraceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Trace table. This table contains
objects for tracing the sonet section and path."
::= { slSonetOhTrace 1 }
slSonetTraceEntry OBJECT-TYPE
SYNTAX SlSonetTraceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the trace table. Entries exist for active sonet
interfaces. The objects in this table are used to verify
continued connection between the two ends of the line."
INDEX { ifIndex }
::= { slSonetTraceTable 1 }
SlSonetTraceEntry ::=
SEQUENCE {
slSonetTraceMode INTEGER,
slSonetTraceToTransmit DisplayString,
slSonetTraceToExpect DisplayString,
slSonetTraceFailure TruthValue,
slSonetTraceReceived DisplayString
}
slSonetTraceMode OBJECT-TYPE
SYNTAX INTEGER {
enable(1), -- notification and rdi
disable(2), -- no notification and no rdi
monitoring(3) -- only notification and no rdi
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determine the Trace Message Mode."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 1 }
slSonetTraceToTransmit OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..62))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sonet Trace To Transmit. This is string that
is transmitted to perform Sonet trace
diagnostics. The trace string is repetitively
transmited so that a trace receiving terminal can
verify its continued connection to the intended
transmitter. The default value is a zero-length string.
Unless this object is set to a non-zero length string,
tracing will not be performed.
The Agent is responsible to pad the end of the string with <CR><LF>."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 2 }
slSonetTraceToExpect OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..62))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sonet Trace Massage To Expect. The receiving terminal
verifies if the incoming string matches this string.
The value of 'slSonetTraceFailure' indicates whether a
trace mismatch occurred. The default value is a
zero-length string.
The Agent is responsible to pad the end of the string with <CR><LF>."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 3 }
slSonetTraceFailure OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is set to 'true' when Sonet
Section received trace does not match the
'slSonetTraceToExpect'."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 4 }
slSonetTraceReceived OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..62))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to view the Sonet Trace Message that
is received by the receiving terminal.
The Agent is responsible to pad the end of the string with <CR><LF>."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 5 }
-- ----------------------------------------------------------------
--
-- Signal Label Table
--
-- ----------------------------------------------------------------
slSonetSlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetSlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Signal Label table. This table contains
signal label for the sonet path."
::= { slSonetOhSl 1 }
slSonetSlEntry OBJECT-TYPE
SYNTAX SlSonetSlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH Signal Label table. The entries
exist for active sonet lines. The objects in this table are
used to verify continued connection between the two ends of
the line."
INDEX { ifIndex }
::= { slSonetSlTable 1 }
SlSonetSlEntry ::=
SEQUENCE {
slSonetSlToTransmit SignalLabel,
slSonetSlToExpect SignalLabel,
slSonetSlFailure TruthValue,
slSonetSlReceived INTEGER
}
slSonetSlToTransmit OBJECT-TYPE
SYNTAX SignalLabel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sonet Signal Label To Transmit."
REFERENCE
"GR-253-CORE"
::= { slSonetSlEntry 2 }
slSonetSlToExpect OBJECT-TYPE
SYNTAX SignalLabel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sonet Signal Label To Expect."
REFERENCE
"GR-253-CORE"
::= { slSonetSlEntry 3 }
slSonetSlFailure OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is set to 'true' when Sonet
received signal label does not match the 'slSonetSlToExpect'."
REFERENCE
"GR-253-CORE"
::= { slSonetSlEntry 4 }
slSonetSlReceived OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to view the Sonet Signal Label that is
received by the receiving terminal."
REFERENCE
"GR-253-CORE"
::= { slSonetSlEntry 5 }
-- ----------------------------------------------------------------
--
-- Packets Over Sonet/Sdh (POS) Performance Monitoring (PM) Table
--
-- ----------------------------------------------------------------
slSonetPosTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetPosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The POS PM Table."
::= { slSonetPos 1 }
slSonetPosEntry OBJECT-TYPE
SYNTAX SlSonetPosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries exist for active Trunk sonet lines
ifType = pos(171). The objects in this table are
used to moitor the POS layer."
INDEX { ifIndex }
::= { slSonetPosTable 1 }
SlSonetPosEntry ::=
SEQUENCE {
slSonetPosFcs Gauge32,
slSonetPosAbort Gauge32,
slSonetPosMinViolation Gauge32,
slSonetPosMaxViolation Gauge32,
slSonetPosRxfifoDiscard Gauge32,
slSonetPosPacketReceived Counter64,
slSonetPosPacketReceivedOk Counter64
}
slSonetPosFcs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of FCS Errors."
::= { slSonetPosEntry 1 }
slSonetPosAbort OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of Aborted packets."
::= { slSonetPosEntry 2 }
slSonetPosMinViolation OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of Minimum length violation packets."
::= { slSonetPosEntry 3 }
slSonetPosMaxViolation OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of Maximum length violation packets."
::= { slSonetPosEntry 4 }
slSonetPosRxfifoDiscard OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of packets discarded due to RXFIFO error."
::= { slSonetPosEntry 5 }
slSonetPosPacketReceived OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of packets received."
::= { slSonetPosEntry 6 }
slSonetPosPacketReceivedOk OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of error free packets."
::= { slSonetPosEntry 7 }
-- ----------------------------------------------------------------
--
-- Automatic Laser Shutdown (ALS) Configuration Table
--
-- ----------------------------------------------------------------
slSonetAlsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetAlsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ALS configuration Table."
::= { slSonetAls 1 }
slSonetAlsEntry OBJECT-TYPE
SYNTAX SlSonetAlsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries exist for active sonet lines
ifType = sonet(39). The objects in this table are
used to configure the ALS algorithm."
INDEX { ifIndex }
::= { slSonetAlsTable 1 }
SlSonetAlsEntry ::=
SEQUENCE {
slSonetAlsMode INTEGER,
slSonetLosDeclareTime INTEGER,
slSonetTestPulseTime INTEGER,
slSonetManualPulseTime INTEGER,
slSonetAutomaticPulseTime INTEGER,
slSonetAutomaticDelayTime INTEGER,
slSonetLaserTestActivate INTEGER,
slSonetLaserManualActivate INTEGER
}
slSonetAlsMode OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the ALS algorithm.
Note that the if the Laser Admin Status is 'down' the
ALS mechanism is not operational."
::= { slSonetAlsEntry 1 }
slSonetLosDeclareTime OBJECT-TYPE
SYNTAX INTEGER {
ms500(1), -- 500 ms
ms550(2), -- 550 ms
ms600(3) -- 600 ms
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to declare optical LOS present or clear: 550 +- 50 msec."
::= { slSonetAlsEntry 2 }
slSonetTestPulseTime OBJECT-TYPE
SYNTAX INTEGER {
s80(1), -- 80 sec
s90(2), -- 90 sec
s100(3) -- 100 sec
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual restart for test Pulse time (in manual restart) - 90+-10 sec."
::= { slSonetAlsEntry 3 }
slSonetManualPulseTime OBJECT-TYPE
SYNTAX INTEGER {
ms1750(1), -- 1.75 Sec
ms2000(2), -- 2.0 sec
ms2250(3) -- 2.25 sec
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual restart Pulse time (in manual mode) - 2+-0.25 sec."
::= { slSonetAlsEntry 4 }
slSonetAutomaticPulseTime OBJECT-TYPE
SYNTAX INTEGER {
ms1750(1), -- 1.75 Sec
ms2000(2), -- 2.0 sec
ms2250(3) -- 2.25 sec
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec."
::= { slSonetAlsEntry 5 }
slSonetAutomaticDelayTime OBJECT-TYPE
SYNTAX INTEGER (60..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In Automatic mode. The delay between two laser re-activations."
::= { slSonetAlsEntry 6 }
slSonetLaserTestActivate OBJECT-TYPE
SYNTAX INTEGER { activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate the laser for test operation."
::= { slSonetAlsEntry 7 }
slSonetLaserManualActivate OBJECT-TYPE
SYNTAX INTEGER { activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate the laser manual operation."
::= { slSonetAlsEntry 8 }
-- ----------------------------------------------------------------
--
-- Frame Structure Configuration Table
--
-- ----------------------------------------------------------------
slSonetFsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetFsEntry
MAX-ACCESS not-accessible -- deprecated
STATUS current
DESCRIPTION
"The frame structure configuration Table.
In order to define a new path the NMS should create and configure
an entry in this table.
The table is also used to monitor the status of the LOP
alarm per path."
::= { slSonetFs 1 }
slSonetFsEntry OBJECT-TYPE
SYNTAX SlSonetFsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries exist for sonet paths
ifType = sonet(39). The objects in this table are
used to configure the frame structure.
Each OC-N line interface shall maintain a static
table with number of lines equal to the N.
Initially the table will be initialized to STS-Nc."
INDEX { slSonetFsIfIndex,
slSonetFsSts }
::= { slSonetFsTable 1 }
SlSonetFsEntry ::=
SEQUENCE {
slSonetFsIfIndex InterfaceIndex,
slSonetFsSts INTEGER,
slSonetFsWidth INTEGER,
slSonetFsFullPathTermination TruthValue,
slSonetFsGranularity INTEGER
}
slSonetFsIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index."
::= { slSonetFsEntry 1 }
slSonetFsSts OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the first STS in the path.
Note that no all values are legal because there is no
support for combus with mixed structure"
::= { slSonetFsEntry 2 }
slSonetFsWidth OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number STS's in the path.
The width is only valid for the first STS in the path.
The other STSs of the path will have width=0."
::= { slSonetFsEntry 3 }
slSonetFsFullPathTermination OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FALSE - means partial path termination (only LOP alarm).
TRUE - include full support for path Alarms and PM counters."
::= { slSonetFsEntry 4 }
slSonetFsGranularity OBJECT-TYPE
SYNTAX INTEGER {
vc4(1),
vc3(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is set by the NMS according to the configured frame structure.
Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1).
Otherwise the value should be vc3(2)."
::= { slSonetFsEntry 5 }
-- ----------------------------------------------------------------
--
-- Sonet Traps
--
-- ----------------------------------------------------------------
slSonetFsTableChange NOTIFICATION-TYPE
OBJECTS { slSonetFsIfIndex }
STATUS current
DESCRIPTION
"A slSonetFsTableChange trap is sent when the
content of the slSonetFsTable is changed.
This trap may be used by the NMS to identify
the removal of path interfaces, or addition of
new path interfaces"
::= { slSonetTraps 1 }
END
|