summaryrefslogtreecommitdiff
path: root/MIBS/pbn/NMS-IF-MIB.MIB
blob: 758f3c00b54120f58348b00f5ac9cfedba884fd9 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
NMS-IF-MIB  DEFINITIONS ::= BEGIN

	IMPORTS
        MODULE-IDENTITY,
        OBJECT-TYPE,
            FROM SNMPv2-SMI
        
     	Gauge,TimeTicks
      		FROM RFC1155-SMI
                  
        DisplayString
			FROM RFC1213-MIB
        nmsMgmt
            FROM NMS-SMI 
        PhysAddress 
            FROM SNMPv2-TC;
                        
nmsIfMIB  MODULE-IDENTITY
        LAST-UPDATED    "200509070000Z"
        ORGANIZATION    ""
        CONTACT-INFO
                	""
			
        DESCRIPTION
                "Analog Voice Interface MIB module.
                 This MIB manages the E&M, FXO, FXS         
                 Interfaces in the router.
                "
        ::= { nmsMgmt 63 }



nmsIfObjects   OBJECT IDENTIFIER ::= { nmsIfMIB 1 }  


--***************************************************************************
--The Aanalog Voice Interface Group
--***************************************************************************

          -- the Voice Interfaces group

          -- Implementation of the Voice Interfaces group is mandatory for
          -- all systems having VOICE interfaces
          -- the Voice Interfaces table

          -- The Voice Interfaces table contains information on the entity's
          -- Voice interfaces.  Each Voice interface is thought of as being
          -- attached to a `subnetwork'.  Note that this term should
          -- not be confused with `subnet' which refers to an
          -- addressing partitioning scheme used in the Internet suite
          -- of protocols.

          vifTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF VIfEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "A list of voice interface entries.  The number of
                      entries is given by the value of ifNumber."
              ::= { nmsIfObjects 1 }

          vifEntry OBJECT-TYPE
              SYNTAX  VIfEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An interface entry containing objects at the
                      subnetwork layer and below for a particular
                      interface."
              INDEX   { vifIndex }
              ::= { vifTable 1 }

          VIfEntry ::=
              SEQUENCE {
                  vifIndex
                      INTEGER,
                  vifDescr
                      DisplayString,
                  vifType
                      INTEGER,
                  vifMtu
                      INTEGER,
                  vifSpeed
                      Gauge,
                  vifPhysAddress
                      PhysAddress,
                  vifAdminStatus
                      INTEGER,
                  vifOperStatus
                      INTEGER,
                  vifLastChange
                      TimeTicks
              }
          vifIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory

              DESCRIPTION
                      "A unique value for each voice interface.  Its value
                      ranges between 1 and the value of vifNumber.  The
                      value for each voice interface must remain constant at
                      least from one re-initialization of the entity's
                      network management system to the next re-
                      initialization."
              ::= { vifEntry 1 }

          vifDescr OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "A textual string containing information about the
                      voice interface.  This string should include the name of
                      the manufacturer, the product name and the version
                      of the hardware interface."
              ::= { vifEntry 2 }

          vifType OBJECT-TYPE
              SYNTAX  INTEGER {
                          other(1),          -- none of the following
                          voiceEM(100),       -- voice recEive and transMit
                   		  voiceFXO(101),      -- voice Foreign Exchange Office
                   		  voiceFXS(102)       -- voice Foreign Exchange Station
                      }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The type of Voice interface, distinguished according to
                      the physical/link protocol(s) immediately `below'
                      the network layer in the protocol stack."
              ::= { vifEntry 3 }

          vifMtu OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The size of the largest datagram which can be
                      sent/received on the voice interface, specified in
                      octets.  in fact,for voice interface,this value should be 0"
              ::= { vifEntry 4 }

          vifSpeed OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "contains a zero value."
              ::= { vifEntry 5 }

          vifPhysAddress OBJECT-TYPE
              SYNTAX  PhysAddress
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "contains an octet string of zero length."
              ::= { vifEntry 6 }

          vifAdminStatus OBJECT-TYPE
              SYNTAX  INTEGER {
                          up(1),       -- ready to pass packets
                   		  down(2),
                   		  testing(3)   -- in some test mode
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The desired administrative status of the
                      Analog Telephony interface port."
              ::= { vifEntry 7 }

          vifOperStatus OBJECT-TYPE
              SYNTAX  INTEGER {
                          up(1),       -- ready to pass packets
                   		  down(2),
                   		  testing(3),  -- in some test mode
                   		  unknown(4),  -- status can not be determined
                                	   -- for some reason.
                   		  dormant(5)
                      }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The current operational state of the interface.
                      The testing(3) state indicates that no operational
                      packets can be passed."
              ::= { vifEntry 8 }

          vifLastChange OBJECT-TYPE
              SYNTAX  TimeTicks
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The value of sysUpTime at the time the interface
                      entered its current operational state.  If the
                      current state was entered prior to the last re-
                      initialization of the local network management
                      subsystem, then this object contains a zero
                      value."
              ::= { vifEntry 9 }              
              
              

          ifStormControlTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF IfStormControlEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "A list of interface entries.  The number of
                      entries is given by the value of ifNumber."
              ::= { nmsIfObjects 2 }

          ifStormControlEntry OBJECT-TYPE
              SYNTAX  IfStormControlEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An interface entry containing objects at the
                      subnetwork layer and below for a particular
                      interface."
              INDEX   { ifIndex }
              ::= { ifStormControlTable 1 }

          IfStormControlEntry ::=
              SEQUENCE {
                  ifIndex
                      INTEGER,
                  ifStormControlBroadcast
                      INTEGER,
                  ifStormControlMulticast
                      INTEGER,
                  ifStormControlUnicast
                      INTEGER,
              }
          ifIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory

              DESCRIPTION
                      "A unique value for each voice interface.  Its value
                      ranges between 1 and the value of vifNumber.  The
                      value for each voice interface must remain constant at
                      least from one re-initialization of the entity's
                      network management system to the next re-
                      initialization."
              ::= { ifStormControlEntry 1 }


          ifStormControlBroadcast OBJECT-TYPE
              SYNTAX  INTEGER(10..1000000)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "Interface Storm Control Broadcast, range is 10-1000000kbps"
              ::= { ifStormControlEntry 2 }

          ifStormControlMulticast OBJECT-TYPE
              SYNTAX  INTEGER(10..1000000)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "Interface Storm Control Multicast, range is 10-1000000kbps"
              ::= { ifStormControlEntry 3 }

          ifStormControlUnicast OBJECT-TYPE
              SYNTAX  INTEGER(10..1000000)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "Interface Storm Control Unicast, range is 10-1000000kbps"
              ::= { ifStormControlEntry 4 }

 --ifSfpParameterTable
             ifSfpParameterTable OBJECT-TYPE
                 SYNTAX  SEQUENCE OF ifSfpParameterEntry
                 ACCESS  not-accessible
                 STATUS  mandatory
                 DESCRIPTION
                          "A list of sfp property table entries."
                 ::= { nmsIfObjects 7 }

             ifSfpParameterEntry OBJECT-TYPE
                 SYNTAX ifSfpParameterEntry
                 ACCESS  not-accessible
                 STATUS  mandatory
                 DESCRIPTION
                          "A collection of additional objects in the
                          sfp property table."
                 INDEX { IfIndex }
             ::= { ifSfpParameterTable 1 }

             ifSfpParameterEntry ::=
                 SEQUENCE {
                     IfIndex
                         INTEGER,
                     txPower
                         INTEGER,
                     rxPower
                         INTEGER,   
                     temperature
                         INTEGER,
                     voltage
                         INTEGER,
                     curr
                         INTEGER                           
                 }

             IfIndex OBJECT-TYPE
                 SYNTAX  INTEGER
                 ACCESS  read-only
                 STATUS  mandatory
                 DESCRIPTION
                         "The only diid of port in System."
                 ::= { ifSfpParameterEntry 1 } 
        
             txPower OBJECT-TYPE
                 SYNTAX  INTEGER
                 ACCESS  read-only
                 STATUS  mandatory
                 DESCRIPTION
                         "The tx power of optical module. The unit is 0.1DBm."
                 ::= { ifSfpParameterEntry 2 } 
    
             rxPower OBJECT-TYPE
                 SYNTAX  INTEGER
                 ACCESS  read-only
                 STATUS  mandatory
                 DESCRIPTION
                         "The rx power of optical module. The unit is 0.1DBm."
                 ::= { ifSfpParameterEntry 3 } 
     
             temperature OBJECT-TYPE
                 SYNTAX  INTEGER
                 ACCESS  read-only
                 STATUS  mandatory
                 DESCRIPTION
                         "Sfp module temperature. The unit is 1/256 degree."
                 ::= { ifSfpParameterEntry 4 } 
    
             voltage OBJECT-TYPE
                 SYNTAX  INTEGER
                 ACCESS  read-only
                 STATUS  mandatory
                 DESCRIPTION
                         "Sfp module volt. The unit is 0.1mV."
                 ::= { ifSfpParameterEntry 5 } 
    
             curr OBJECT-TYPE
                 SYNTAX  INTEGER
                 ACCESS  read-only
                 STATUS  mandatory
                 DESCRIPTION
                         "Sfp module bias current. The unit is 2mA."
                 ::= { ifSfpParameterEntry 6 }
              
              
              
                 
END