1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
|
NETTRACK-E3METER-SNMP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32,
enterprises
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
TruthValue
FROM SNMPv2-TC
;
nettrack OBJECT IDENTIFIER
::= { enterprises 21695 }
public OBJECT IDENTIFIER
::= { nettrack 1 }
e3Mib
MODULE-IDENTITY
LAST-UPDATED "201810090000Z"
ORGANIZATION "net-track GmbH"
CONTACT-INFO "net-track GmbH
Duensstrasse 1
3186 Duedingen
Switzerland
www.net-track.ch"
DESCRIPTION "Management Information for E3METER IPM products
www.e3meter.com"
REVISION "201810090000Z"
DESCRIPTION "Added RCM traps."
REVISION "201810080000Z"
DESCRIPTION "Added RCM-related stuff."
REVISION "201604180000Z"
DESCRIPTION "Added e3IpmAlarmTable."
REVISION "201602030000Z"
DESCRIPTION "Added traps."
REVISION "201204120000Z"
DESCRIPTION "Added import of TEXTUAL-CONVENTION."
REVISION "201111020000Z"
DESCRIPTION "Added channel type and channel groups."
REVISION "201108190000Z"
DESCRIPTION "Added e3IpmChannelName."
REVISION "201101260000Z"
DESCRIPTION "Corrected some syntax errors for very picky parsers."
REVISION "201012060000Z"
DESCRIPTION "Added sensor data."
REVISION "201010200000Z"
DESCRIPTION "Initial version of this MIB module."
::= { public 10 }
e3Ipm OBJECT IDENTIFIER
::= { e3Mib 7 }
-- ===========================================================================
-- Textual conventions
--
Watts ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Watts"
SYNTAX INTEGER
VoltAmpereReactives ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Volt-ampere reactives"
SYNTAX Integer32
VoltAmperes ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Volt-amperes"
SYNTAX Integer32
WattHours ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Watt hours"
SYNTAX Integer32
VoltAmpereReactiveHours ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Volt-ampere reactive hours"
SYNTAX Integer32
VoltAmpereHours ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Volt-ampere hours"
SYNTAX Integer32
MilliAmperes ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Milli-amperes"
SYNTAX Integer32
MilliVolts ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Milli-volts"
SYNTAX Integer32
MilliHertz ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Milli-hertz"
SYNTAX Integer32
DeciDegreesCelsius ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Deci-degrees celsius"
SYNTAX Integer32
Permil ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Per mil"
SYNTAX INTEGER
-- ===========================================================================
-- Agent information
--
e3IpmInfo OBJECT IDENTIFIER
::= { e3Ipm 1 }
e3IpmInfoSerial OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number."
::= { e3IpmInfo 1 }
e3IpmInfoModel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Model number."
::= { e3IpmInfo 2 }
e3IpmInfoHWVersion OBJECT-TYPE
SYNTAX INTEGER {
rev-a (0),
rev-b (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware revision."
::= { e3IpmInfo 3 }
e3IpmInfoFWVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Integer representation of the firmware revision
(major.minor) represented as a 16 bit integer."
::= { e3IpmInfo 4 }
e3IpmInfoMeters OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of power meters in this IPS."
::= { e3IpmInfo 5 }
-- ===========================================================================
-- IPM meters
--
e3IpmMeterTable OBJECT-TYPE
SYNTAX SEQUENCE OF E3IpmMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The e3IpmMeterTable holds information related to the
powermeters of all IPS nodes."
::= { e3Ipm 2 }
e3IpmMeterEntry OBJECT-TYPE
SYNTAX E3IpmMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Holds the information related to one specific powermeter."
INDEX { e3IpmMeter }
::= { e3IpmMeterTable 1 }
E3IpmMeterEntry ::= SEQUENCE {
e3IpmMeter Integer32,
e3IpmEnergyP WattHours,
e3IpmEnergyQ VoltAmpereReactiveHours,
e3IpmEnergyS VoltAmpereHours,
e3IpmPowerP Watts,
e3IpmPowerQ VoltAmpereReactives,
e3IpmPowerS VoltAmperes,
e3IpmUrms MilliVolts,
e3IpmIrms MilliAmperes,
e3IpmFrequency MilliHertz,
e3IpmChannelName OCTET STRING,
e3IpmChannelType INTEGER
}
e3IpmMeter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the powermeter of this IPS."
::= { e3IpmMeterEntry 1 }
e3IpmEnergyP OBJECT-TYPE
SYNTAX WattHours
UNITS "Wh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active energy in watt hours."
::= { e3IpmMeterEntry 2 }
e3IpmEnergyQ OBJECT-TYPE
SYNTAX VoltAmpereReactiveHours
UNITS "varh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reactive energy in volt-ampere reactives hours."
::= { e3IpmMeterEntry 3 }
e3IpmEnergyS OBJECT-TYPE
SYNTAX VoltAmpereHours
UNITS "VAh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Apparent energy in volt-ampere hours."
::= { e3IpmMeterEntry 4 }
e3IpmPowerP OBJECT-TYPE
SYNTAX Watts
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active power at a given instant."
::= { e3IpmMeterEntry 5 }
e3IpmPowerQ OBJECT-TYPE
SYNTAX VoltAmpereReactives
UNITS "var"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reactive power at a given instant."
::= { e3IpmMeterEntry 6 }
e3IpmPowerS OBJECT-TYPE
SYNTAX VoltAmperes
UNITS "VA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Apparent power at a given instant."
::= { e3IpmMeterEntry 7 }
e3IpmUrms OBJECT-TYPE
SYNTAX MilliVolts
UNITS "mV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RMS voltage at a given instant."
::= { e3IpmMeterEntry 8 }
e3IpmIrms OBJECT-TYPE
SYNTAX MilliAmperes
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RMS current at a given instant."
::= { e3IpmMeterEntry 9 }
e3IpmFrequency OBJECT-TYPE
SYNTAX MilliHertz
UNITS "mHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency measured a given instant."
::= { e3IpmMeterEntry 10 }
e3IpmChannelName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel name."
::= { e3IpmMeterEntry 11 }
e3IpmChannelType OBJECT-TYPE
SYNTAX INTEGER {
live-wire (0),
neutral-wire (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel type: For neutral wire channels, only I_rms will
contain meaningful values."
::= { e3IpmMeterEntry 12 }
-- ===========================================================================
-- IPM sensors
--
e3IpmSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF E3IpmSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The e3IpmSensorTable holds information related to the
sensor of this IPM."
::= { e3Ipm 3 }
e3IpmSensorEntry OBJECT-TYPE
SYNTAX E3IpmSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Holds the information related to one specific sensor."
INDEX { e3IpmSensor }
::= { e3IpmSensorTable 1 }
E3IpmSensorEntry ::= SEQUENCE {
e3IpmSensor Integer32,
e3IpmSensorType INTEGER,
e3IpmSensorVersion OCTET STRING,
e3IpmSensorTemperatureCelsius DeciDegreesCelsius,
e3IpmSensorHumidity Permil
}
e3IpmSensor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sensor port number."
::= { e3IpmSensorEntry 1 }
e3IpmSensorType OBJECT-TYPE
SYNTAX INTEGER {
none (0),
temp (1),
temp-humidity (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sensor type."
::= { e3IpmSensorEntry 2 }
e3IpmSensorVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sensor version."
::= { e3IpmSensorEntry 3 }
e3IpmSensorTemperatureCelsius OBJECT-TYPE
SYNTAX DeciDegreesCelsius
UNITS "deg-C/10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature in tenth degrees."
::= { e3IpmSensorEntry 4 }
e3IpmSensorHumidity OBJECT-TYPE
SYNTAX Permil
UNITS "/1000"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Relative humidity in per mil."
::= { e3IpmSensorEntry 5 }
-- ===========================================================================
-- IPM predefined channel groups
--
e3IpmPGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF E3IpmPGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The e3IpmPGroupTable holds information related to predefined
channel groups."
::= { e3Ipm 4 }
e3IpmPGroupEntry OBJECT-TYPE
SYNTAX E3IpmPGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Holds the information related to one specific group."
INDEX { e3IpmPGroup }
::= { e3IpmPGroupTable 1 }
E3IpmPGroupEntry ::= SEQUENCE {
e3IpmPGroup Integer32,
e3IpmPGName OCTET STRING,
e3IpmPGMembers Integer32,
e3IpmPGEnergyP WattHours,
e3IpmPGEnergyQ VoltAmpereReactiveHours,
e3IpmPGEnergyS VoltAmpereHours,
e3IpmPGPowerP Watts,
e3IpmPGPowerQ VoltAmpereReactives,
e3IpmPGPowerS VoltAmperes,
e3IpmPGIrms MilliAmperes
}
e3IpmPGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Predefined channel group number."
::= { e3IpmPGroupEntry 1 }
e3IpmPGName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group name."
::= { e3IpmPGroupEntry 2 }
e3IpmPGMembers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit set specifying the channels which are
members of this channel group. If bit 0 is set,
this means that channel CH1 is member of this
group. Bit 1 stands for CH2 and so on."
::= { e3IpmPGroupEntry 3 }
e3IpmPGEnergyP OBJECT-TYPE
SYNTAX WattHours
UNITS "Wh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group active energy in watt hours."
::= { e3IpmPGroupEntry 4 }
e3IpmPGEnergyQ OBJECT-TYPE
SYNTAX VoltAmpereReactiveHours
UNITS "varh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group reactive energy in volt-ampere reactives hours."
::= { e3IpmPGroupEntry 5 }
e3IpmPGEnergyS OBJECT-TYPE
SYNTAX VoltAmpereHours
UNITS "VAh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group apparent energy in volt-ampere hours."
::= { e3IpmPGroupEntry 6 }
e3IpmPGPowerP OBJECT-TYPE
SYNTAX Watts
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group active power at a given instant."
::= { e3IpmPGroupEntry 7 }
e3IpmPGPowerQ OBJECT-TYPE
SYNTAX VoltAmpereReactives
UNITS "var"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group reactive power at a given instant."
::= { e3IpmPGroupEntry 8 }
e3IpmPGPowerS OBJECT-TYPE
SYNTAX VoltAmperes
UNITS "VA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group apparent power at a given instant."
::= { e3IpmPGroupEntry 9 }
e3IpmPGIrms OBJECT-TYPE
SYNTAX MilliAmperes
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group RMS current at a given instant."
::= { e3IpmPGroupEntry 10 }
-- ===========================================================================
-- IPM user defined channel groups
--
e3IpmUGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF E3IpmUGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The e3IpmUGroupTable holds information related to user
defined channel groups."
::= { e3Ipm 5 }
e3IpmUGroupEntry OBJECT-TYPE
SYNTAX E3IpmUGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Holds the information related to one specific group."
INDEX { e3IpmUGroup }
::= { e3IpmUGroupTable 1 }
E3IpmUGroupEntry ::= SEQUENCE {
e3IpmUGroup Integer32,
e3IpmUGName OCTET STRING,
e3IpmUGMembers Integer32,
e3IpmUGEnergyP WattHours,
e3IpmUGEnergyQ VoltAmpereReactiveHours,
e3IpmUGEnergyS VoltAmpereHours,
e3IpmUGPowerP Watts,
e3IpmUGPowerQ VoltAmpereReactives,
e3IpmUGPowerS VoltAmperes,
e3IpmUGIrms MilliAmperes
}
e3IpmUGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"User defined channel group number."
::= { e3IpmUGroupEntry 1 }
e3IpmUGName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group name."
::= { e3IpmUGroupEntry 2 }
e3IpmUGMembers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit set specifying the channels which are
members of this channel group. If bit 0 is set,
this means that channel CH1 is member of this
group. Bit 1 stands for CH2 and so on. If no
members are configured, the group is inactive."
::= { e3IpmUGroupEntry 3 }
e3IpmUGEnergyP OBJECT-TYPE
SYNTAX WattHours
UNITS "Wh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group active energy in watt hours."
::= { e3IpmUGroupEntry 4 }
e3IpmUGEnergyQ OBJECT-TYPE
SYNTAX VoltAmpereReactiveHours
UNITS "varh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group reactive energy in volt-ampere reactives hours."
::= { e3IpmUGroupEntry 5 }
e3IpmUGEnergyS OBJECT-TYPE
SYNTAX VoltAmpereHours
UNITS "VAh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group apparent energy in volt-ampere hours."
::= { e3IpmUGroupEntry 6 }
e3IpmUGPowerP OBJECT-TYPE
SYNTAX Watts
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group active power at a given instant."
::= { e3IpmUGroupEntry 7 }
e3IpmUGPowerQ OBJECT-TYPE
SYNTAX VoltAmpereReactives
UNITS "var"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group reactive power at a given instant."
::= { e3IpmUGroupEntry 8 }
e3IpmUGPowerS OBJECT-TYPE
SYNTAX VoltAmperes
UNITS "VA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group apparent power at a given instant."
::= { e3IpmUGroupEntry 9 }
e3IpmUGIrms OBJECT-TYPE
SYNTAX MilliAmperes
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel group RMS current at a given instant."
::= { e3IpmUGroupEntry 10 }
-- ===========================================================================
-- IPM Alarm Settings
--
e3IpmAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF E3IpmAlarmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Holds alarm settings."
::= { e3Ipm 6 }
e3IpmAlarmTableEntry OBJECT-TYPE
SYNTAX E3IpmAlarmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Holds alarm settings for one specific measured value."
INDEX { e3IpmAlarmIndex }
::= { e3IpmAlarmTable 1 }
E3IpmAlarmTableEntry ::= SEQUENCE {
e3IpmAlarmIndex INTEGER,
e3IpmAlarmState INTEGER,
e3IpmAlarmCritLowSet TruthValue,
e3IpmAlarmCritLow Integer32,
e3IpmAlarmWarnLowSet TruthValue,
e3IpmAlarmWarnLow Integer32,
e3IpmAlarmWarnHighSet TruthValue,
e3IpmAlarmWarnHigh Integer32,
e3IpmAlarmCritHighSet TruthValue,
e3IpmAlarmCritHigh Integer32
}
e3IpmAlarmIndex OBJECT-TYPE
SYNTAX INTEGER {
current-l1 (0),
current-l2 (1),
current-l3 (2),
current-n (3),
temp-int (4),
temp-ext1 (5),
temp-ext2 (6),
rh-ext1 (7),
rh-ext2 (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the alarm described by the current entry. There
are alarms for the current of all phases, for the
temperature and the relative humidity."
::= { e3IpmAlarmTableEntry 1 }
e3IpmAlarmState OBJECT-TYPE
SYNTAX INTEGER {
critical-low (0),
warn-low (1),
normal (2),
warn-high (3),
critical-high (4),
unknown (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows this alarm entries' state. If no alarm settings
are defined, the state is unknown."
::= { e3IpmAlarmTableEntry 2 }
e3IpmAlarmCritLowSet OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if a 'critical low' alarm level for the current
entry is defined, false otherwise."
::= { e3IpmAlarmTableEntry 3 }
e3IpmAlarmCritLow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 'critical low' alarm level for the current entry
in hundredths of the relevant unit (i.e. amperes, degrees
celsius and %RH). If no alarm level is configured, this
reads 0."
::= { e3IpmAlarmTableEntry 4 }
e3IpmAlarmWarnLowSet OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if a 'warn low' alarm level for the current
entry is defined, false otherwise."
::= { e3IpmAlarmTableEntry 5 }
e3IpmAlarmWarnLow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 'warn low' alarm level for the current entry
in hundredths of the relevant unit (i.e. amperes, degrees
celsius and %RH). If no alarm level is configured, this
reads 0."
::= { e3IpmAlarmTableEntry 6 }
e3IpmAlarmWarnHighSet OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if a 'warn high' alarm level for the current
entry is defined, false otherwise."
::= { e3IpmAlarmTableEntry 7 }
e3IpmAlarmWarnHigh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 'warn high' alarm level for the current entry
in hundredths of the relevant unit (i.e. amperes, degrees
celsius and %RH). If no alarm level is configured, this
reads 0."
::= { e3IpmAlarmTableEntry 8 }
e3IpmAlarmCritHighSet OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if a 'critical high' alarm level for the current
entry is defined, false otherwise."
::= { e3IpmAlarmTableEntry 9 }
e3IpmAlarmCritHigh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 'critical high' alarm level for the current entry
in hundredths of the relevant unit (i.e. amperes, degrees
celsius and %RH). If no alarm level is configured, this
reads 0."
::= { e3IpmAlarmTableEntry 10 }
-- ===========================================================================
-- IPM RCM Data
--
e3IpmRcmTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Table holding all residual current monitoring (RCM)
data of this IPS."
::= { e3Ipm 7 }
e3IpmRcmTableEntry OBJECT-TYPE
SYNTAX E3IpmRcmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"One entry in the RCM table."
INDEX { e3IpmRcmChannel }
::= { e3IpmRcmTable 1 }
E3IpmRcmTableEntry ::= SEQUENCE {
e3IpmRcmChannel Integer32,
e3IpmRcmAcLimit MilliAmperes,
e3IpmRcmDcLimit MilliAmperes,
e3IpmRcmStatus Integer32,
e3IpmRcmAc MilliAmperes,
e3IpmRcmDc MilliAmperes
}
e3IpmRcmChannel OBJECT-TYPE
SYNTAX INTEGER {
total(0)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RCM channel: 0 (total) is the total of all phases in this IPS."
::= { e3IpmRcmTableEntry 1 }
e3IpmRcmAcLimit OBJECT-TYPE
SYNTAX MilliAmperes
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The factory configured AC RCM limit. Any measurement
higher than this limit is considered a critical problem."
::= { e3IpmRcmTableEntry 2 }
e3IpmRcmDcLimit OBJECT-TYPE
SYNTAX MilliAmperes
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The factory configured DC RCM limit. Any measurement
higher than this limit is considered a critical problem."
::= { e3IpmRcmTableEntry 3 }
e3IpmRcmStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
valid(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the RcmAc/RcmDc data. If the residual
current cannot be measured, 0 (unknown) is signalled
here, otherwise 1 (valid)."
::= { e3IpmRcmTableEntry 4 }
e3IpmRcmAc OBJECT-TYPE
SYNTAX MilliAmperes
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The latest AC RCM measurement."
::= { e3IpmRcmTableEntry 5 }
e3IpmRcmDc OBJECT-TYPE
SYNTAX MilliAmperes
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The latest DC RCM measurement."
::= { e3IpmRcmTableEntry 6 }
-- ===========================================================================
-- IPM Traps
--
e3IpmTraps OBJECT IDENTIFIER
::= { e3Mib 8 }
-- Current
e3IpmCurrentCritLow NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms }
STATUS current
DESCRIPTION
"The e3IpmCurrentCritLow is triggered when the current
on the given channel is less than or equal to the configured
critical low threshold."
::= { e3IpmTraps 1 }
e3IpmCurrentWarnLow NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms }
STATUS current
DESCRIPTION
"The e3IpmCurrentWarnLow is triggered when the current
on the given channel is less than or equal to the configured
warn low threshold."
::= { e3IpmTraps 2 }
e3IpmCurrentNormal NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms }
STATUS current
DESCRIPTION
"The e3IpmCurrentNormal is triggered when the current
on the given channel is not outside any configured
limits."
::= { e3IpmTraps 3 }
e3IpmCurrentWarnHigh NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms }
STATUS current
DESCRIPTION
"The e3IpmCurrentWarnHigh is triggered when the current
on the given channel is greater than or equal to the
configured warn high threshold."
::= { e3IpmTraps 4 }
e3IpmCurrentCritHigh NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms }
STATUS current
DESCRIPTION
"The e3IpmCurrentCritHigh is triggered when the current
on the given channel is greater than or equal to the
configured critical high threshold."
::= { e3IpmTraps 5 }
-- Temperature
e3IpmTempCritLow NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius }
STATUS current
DESCRIPTION
"The e3IpmTempCritLow is triggered when the temperature
on the given sensor is less than or equal to the configured
critical low threshold."
::= { e3IpmTraps 6 }
e3IpmTempWarnLow NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius }
STATUS current
DESCRIPTION
"The e3IpmTempWarnLow is triggered when the temperature
on the given sensor is less than or equal to the configured
warn low threshold."
::= { e3IpmTraps 7 }
e3IpmTempNormal NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius }
STATUS current
DESCRIPTION
"The e3IpmTempNormal is triggered when the temperature
on the given sensor is not outside any configured
limits."
::= { e3IpmTraps 8 }
e3IpmTempWarnHigh NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius }
STATUS current
DESCRIPTION
"The e3IpmTempWarnHigh is triggered when the temperature
on the given sensor is greater than or equal to the
configured warn high threshold."
::= { e3IpmTraps 9 }
e3IpmTempCritHigh NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius }
STATUS current
DESCRIPTION
"The e3IpmTempCritHigh is triggered when the temperature
on the given sensor is greater than or equal to the
configured critical high threshold."
::= { e3IpmTraps 10 }
-- Relative Humidity
e3IpmRHCritLow NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity }
STATUS current
DESCRIPTION
"The e3IpmRHCritLow is triggered when the relative humidity
on the given sensor is less than or equal to the configured
critical low threshold."
::= { e3IpmTraps 11 }
e3IpmRHWarnLow NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity }
STATUS current
DESCRIPTION
"The e3IpmRHWarnLow is triggered when the relative humidity
on the given sensor is less than or equal to the configured
warn low threshold."
::= { e3IpmTraps 12 }
e3IpmRHNormal NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity }
STATUS current
DESCRIPTION
"The e3IpmRHNormal is triggered when the relative humidity
on the given sensor is not outside any configured
limits."
::= { e3IpmTraps 13 }
e3IpmRHWarnHigh NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity }
STATUS current
DESCRIPTION
"The e3IpmRHWarnHigh is triggered when the relative humidity
on the given sensor is greater than or equal to the
configured warn high threshold."
::= { e3IpmTraps 14 }
e3IpmRHCritHigh NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity }
STATUS current
DESCRIPTION
"The e3IpmRHCritHigh is triggered when the relative humidity
on the given sensor is greater than or equal to the
configured critical high threshold."
::= { e3IpmTraps 15 }
-- RCM Alarms
e3IpmRcmAcNormal NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmRcmChannel, e3IpmRcmAc }
STATUS current
DESCRIPTION
"The e3IpmRcmAcNormal is triggered when the AC part of
the residual current falls below the
factory-configured limit."
::= { e3IpmTraps 16 }
e3IpmRcmAcCritHigh NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmRcmChannel, e3IpmRcmAc }
STATUS current
DESCRIPTION
"The e3IpmRcmAcCritHigh is triggered when the AC part
of the residual current is greater than the
factory-configured limit."
::= { e3IpmTraps 17 }
e3IpmRcmDcNormal NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmRcmChannel, e3IpmRcmDc }
STATUS current
DESCRIPTION
"The e3IpmRcmDcNormal is triggered when the DC part of
the residual current falls below the
factory-configured limit."
::= { e3IpmTraps 18 }
e3IpmRcmDcCritHigh NOTIFICATION-TYPE
OBJECTS { e3IpmInfoSerial, e3IpmRcmChannel, e3IpmRcmDc }
STATUS current
DESCRIPTION
"The e3IpmRcmDcCritHigh is triggered when the DC part
of the residual current is greater than the
factory-configured limit."
::= { e3IpmTraps 19 }
END
|