1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
|
-- RPS S.p.A enterprise MIB definition
-- Copyright (c) RPS S.p.A.
-- Version: 1.0 by Michele Marcon
-- Date: 1.04.2016
-- Title: RIELLOMDU-MIB
-- MDU-MIB { iso org(3) dod(6) internet(1) private(4)
-- enterprises(1) riello(5491) }
-- ************************************************************************
-- ************************************************************************
RIELLOMDU-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
rielloMIB
FROM RIELLO-MIB;
mduMIB OBJECT IDENTIFIER ::= { rielloMIB 11 }
mduIdent OBJECT IDENTIFIER ::= { mduMIB 1 }
mduIdentManufacturer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the mdu manufacturer."
::= { mduIdent 1 }
mduIdentModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mdu Model designation."
::= { mduIdent 2 }
mduIdentSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mdu Software version."
::= { mduIdent 3 }
mduIdentIOConfiguration OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mdu input/output configuration (1 for Mono/mono, 4 for Tri/tri)."
::= { mduIdent 4 }
mduIdentInputSockets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of mdu input sockets."
::= { mduIdent 5 }
mduIdentOutputSockets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of mdu output sockets."
::= { mduIdent 6 }
mduIdentNominalCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mdu nominal current (A)."
::= { mduIdent 7 }
mduIdentNominalVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mdu nominal voltage (V)."
::= { mduIdent 8 }
mduIdentNominalFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mdu nominal frequency (0.1 Hz)."
::= { mduIdent 9 }
mduStatus OBJECT IDENTIFIER ::= { mduMIB 2 }
mduLineAFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency of source A (0.1 Hz)."
::= { mduStatus 1 }
mduLineAVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of source 1 (V)."
::= { mduStatus 2 }
mduLineACurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of line A (0.1 A)."
::= { mduStatus 3 }
mduOutput OBJECT-TYPE
SYNTAX SEQUENCE OF MduOutputSockets
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of output table entries."
::= { mduStatus 4 }
mduOutputSockets OBJECT-TYPE
SYNTAX MduOutputSockets
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing information applicable to a
particular output line."
INDEX { mduOutputLineIndex }
::= { mduOutput 1 }
MduOutputSockets ::=
SEQUENCE {
mduOutputLineIndex
INTEGER,
mduOutputCurrent
INTEGER,
mduOutputDisabled
INTEGER,
mduOutputOverload
INTEGER,
mduOutputStatus
INTEGER
}
mduOutputLineIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The line identifier."
::= { mduOutputSockets 1 }
mduOutputCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Output current (0.1 A)"
::= { mduOutputSockets 2 }
mduOutputDisabled OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1->line active, 2->line deactivated"
::= { mduOutputSockets 3 }
mduOutputOverload OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1->line ok, 2->line deactivated for overload"
::= { mduOutputSockets 4 }
mduOutputStatus OBJECT-TYPE
SYNTAX INTEGER{
off(0),
on(1),
shutdownActive(2),
shutdownImminent(3),
restoreActive(4),
overload(5),
locked(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0=OFF
1=ON
2= Shutdown active (when a CS or a CR command is received but shutdown is not yet been executed and the "Imminent time" is not reached)
3= Shutdown imminent (S01 ÷ S08 code)
4= Restore active (when after that a CR command is received and the shutdown has been acted but the restore delay time is not expired)
5= Overload alarm (F01 ÷ F08 code)
6= Locked: OFF for overload (L01 ÷ L08 code)"
::= { mduOutputSockets 5 }
mduLowInputVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1= yes, 0= no."
::= { mduStatus 5 }
mduHighInputVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1= yes, 0= no."
::= { mduStatus 6 }
mduLowInputCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1= yes, 0= no."
::= { mduStatus 7 }
mduHighInputCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1= yes, 0= no."
::= { mduStatus 8 }
mduPowerFailAux1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1= yes, 0= no."
::= { mduStatus 9 }
mduPowerFailAux2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1= yes, 0= no."
::= { mduStatus 10 }
mduManualBypass OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1= on manual bypass, 0= no."
::= { mduStatus 11 }
mduTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The temperature (°C)."
::= { mduStatus 12 }
mduCommand OBJECT IDENTIFIER ::= { mduMIB 3 }
mduCommandCode OBJECT-TYPE
SYNTAX INTEGER {
shutdown(1),
restore(2),
commandDelete(3),
testPanel(22)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determines the nature of the action to be
taken at the time when the countdown of the
mduShutdownDelay and mduRestoreDelay objects reaches zero.
Setting this object to shutdown(1) indicates that
the specified sockets mduOutputSocketApplyCommand will yurn off.
Setting this object to restore(2) indicates that the specified output
sockets will turn on.
command delete(3) will delete the applied command, test panel will perform
a test of LCD panel and audible alarm"
::= { mduCommand 1 }
mduShutdownDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object will shutdown (i.e., turn off)
either the MDU output socket by the value of mduCommandCode
at the time of shutdown after the indicated number of seconds.
Setting this object to 0 will cause the shutdown to occur
immediately"
::= { mduCommand 2 }
mduRestoreDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The restore delay."
::= { mduCommand 3 }
mduOutputSocketApplyCommand OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify the socket to apply the command, the value 0 apply to all sockets."
::= { mduCommand 4 }
mduCommandResult OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The command result, refer to the follow codes:
0+mduCommandCode Command in progress
256+mduCommandCode Wrong Command code
512+mduCommandCode Command is not handled
768+mduCommandCode Parameter out of range
3584+mduCommandCode Command sent to MDU
3840+mduCommandCode Command executed"
::= { mduCommand 5 }
mduTraps OBJECT IDENTIFIER ::= { mduMIB 4 }
-- This section defines the well-known notifications sent by
-- MDU agents.
-- Care must be taken to insure that no particular notification
-- is sent to a single receiving entity more often than once
-- every minute.
mduNormal TRAP-TYPE
ENTERPRISE mduTraps
DESCRIPTION "This trap is sent when MDU is on normal status"
::= 1
mduAnomaly TRAP-TYPE
ENTERPRISE mduTraps
DESCRIPTION "This trap is sent when MDU is has some anomaly and is resent every minute"
::= 2
mduFault TRAP-TYPE
ENTERPRISE mduTraps
DESCRIPTION "This trap is sent when MDU is has some fault and is resent every minute"
::= 3
mduLock TRAP-TYPE
ENTERPRISE mduTraps
DESCRIPTION "This trap is sent when MDU is locked and is resent every minute"
::= 4
mduManualBypassEnabled TRAP-TYPE
ENTERPRISE mduTraps
DESCRIPTION "This trap is sent when MDU is on manual bypass and is resent every minute"
::= 5
END
|