1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
|
RUGGEDCOM-SYS-INFO-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-IDENTITY,
OBJECT-TYPE, Integer32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue,
DisplayString FROM SNMPv2-TC
OBJECT-GROUP FROM SNMPv2-CONF
ruggedcomMgmt FROM RUGGEDCOM-MIB;
rcSysInfo MODULE-IDENTITY
LAST-UPDATED "201711021000Z" -- Nov. 02, 10:00 EST 2017
ORGANIZATION "Siemens Canada Ltd., Process Industries and Drives"
CONTACT-INFO
"Postal: Siemens Canad Ltd.
300 Applewood Crescent
Concord, Ontario,
L4K 5C7 Canada
Tel: 1-905-856-5288
E-Mail: support.canada.automation@siemens.com"
DESCRIPTION
"RuggedCom system information MIB."
REVISION "201711021000Z" -- Nov. 02, 10:00 EST 2017
DESCRIPTION
"Added new object rcDeviceErrSystem."
REVISION "201709201100Z" -- Sept. 20, 11:00 EST 2017
DESCRIPTION
"Updated DESCRIPTION of objects rcDeviceErrRadiusServerUnreachable and
rcDeviceErrTacacsServerUnreachable."
REVISION "201702151000Z" -- Feb 15, 10:00 EST 2017
DESCRIPTION
"Updated ORGANIZATION and CONTACT-INFO. Updated DESCRIPTION of
object rcDeviceErrNtpServerUnreachable."
REVISION "201410081700Z" -- Oct 08, 17:00 EST 2014
DESCRIPTION
"Added new board IDs in RcMainBoard TEXTUAL-CONVENTION."
REVISION "201208301700Z" -- Aug 30, 17:00 EST 2012
DESCRIPTION
"Added new objects: rcDeviceStsKeysDflt and rcDeviceInfoMinBootSwVer
related to the device security in the group
rcSysDeviceSecurityGroup01."
REVISION "201206011700Z" -- Jun 01, 17:00 EST 2012
DESCRIPTION
"Added new objects rcDeviceStsPwdsWeak related to the device
security in the group rcSysDeviceSecurityGroup."
REVISION "201104051000Z" -- Apr 05, 10:00 EST 2011
DESCRIPTION
"Extended RcHardwareStatus textual convention. Added
'notConnected(4)' value."
REVISION "201009161300Z" -- Sep 16, 13:00 EST 2010
DESCRIPTION
"Added Fan Bank Module hardware status elements.
Added new objects:
rcDeviceStsFanBank1 and rcDeviceStsFanBank2
Added new types related to module Slot and state change."
REVISION "200905171300Z" -- May 17, 13:00 EST 2009
DESCRIPTION
"Fixed description for object rcDeviceCommClearSyslog.
Added new object:
rcDeviceCommClearLogs
Removed statement about mandatory groups from groups descriptions."
REVISION "200812171300Z" -- Dec 17, 13:00 EST 2008
DESCRIPTION
"Fixed mistyped object name for rcDeviceStsErrorAlarm in
rcSysStsObjectsGroup objects list.
Added new object:
rcDeviceCommIdentify."
REVISION "200810091000Z" -- Oct 09, 10:00 EST 2008
DESCRIPTION
"Added new objects:
rcDeviceStsErrorAlarm,
rcDeviceStsFailSafeRelay,
rcDeviceStsNoOfActiveAlarms."
REVISION "200809121400Z" -- Sep 12, 14:00 EST 2008
DESCRIPTION
"Adde new enumeration labels for rcDeviceInfoMainBoardType
for new hardware platform support."
REVISION "200802151400Z" -- Feb 15, 14:00 EST 2008
DESCRIPTION
"Removed '_' characters from enumeration labels.
Added new objects:
rcDeviceInfoPendingBootSwVersion
rcDeviceInfoPendingMainSwVersion
rcDeviceInfoCfgRevision
rcDeviceCommReset
rcDeviceCommLoadDefaultCfg,
rcDeviceCommClearAlarms,
rcDeviceCommClearSyslog
"
REVISION "200609061400Z" -- Sept 6, 14:00 EST 2006
DESCRIPTION
"The initial version of RuggedCom system information MIB."
::= { ruggedcomMgmt 2 }
RcHardwareStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A status of a hardware module in the RuggedCom device."
SYNTAX INTEGER {
notPresent(1), -- the module is not present
functional(2), -- the module is present and functional
notFunctional(3), -- the module is present, but not
-- functional
notConnected(4) -- the module is present, but not connected
}
RcFanStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The status of a fan-bank."
SYNTAX INTEGER {
notPresent(1), -- this bank is not present
failed(2), -- this bank has failed due to a mechanical
-- or sensor problem
standby(3), -- the fan system is active, but this bank
-- is designated as a backup and not
off(4), -- currently spinning this bank is off
on(5) -- this bank is currently spinning
}
RcHotswapModuleSlot ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A physical slot holding the hotswapable module (ROX 2 specific).
As the value 0 is forbidden in SNMP enumerations, this value is the
value 1 higher than some other ROX 2 slot values"
SYNTAX INTEGER {
pm1(1),
lm1(2),
lm2(3),
lm3(4),
cm(5),
sm(6),
lm4(7),
lm5(8),
lm6(9),
pm2(10),
main(11), -- The backplane is not hotswapable
em(12) -- This is a logical slot not a physical one,
-- not hotswapable
}
RcHotswapModuleState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A status of a hardware module in the RuggedCom device."
SYNTAX INTEGER {
empty(1), -- the module is not present
disabled(2), -- the module is present, but has been
-- disabled by configuration.
resetting(3), -- the module is present and is on its way
-- to either operating or failed.
operating(4), -- the module is present and has reached
-- the operating state
failed(5), -- the module is present, but cannot be
unknown(255) -- booted unknown status
}
RcMainBoard ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A main board type code. This textual convention will be updated
any time when new main board type is developed."
SYNTAX INTEGER {
rsMCPU2(1), -- RSMCPU, otherwise known as
-- 40-00-0026 Rev A1
rs400revB2(2),
rmc30(3),
rs900revB1F(4), -- RS900 with 6 copper,
-- 2 fiber and 1 optional port
rs900revB1noF(5), -- RS900 with 8 copper and 1
-- optional port
rs1600M(6), -- RS1600 Modular, obsolete
rs400revC1(7),
rsG2100(8),
rs900G(9),
rsG2200(10),
rs969(11),
rs900v2F(12), -- RS900 88E6095 based with
-- 6 copper, 2 fiber and
rs900v2noF(13), -- 1 optional port RS900
-- 88E6095 based with 8 copper
-- and 1 optional port
rs416(15),
rsRMC30Ksz80001(16),
rs930(17),
rs969v2(18),
rs910(19),
rs920(20),
rs940G(21),
rsi80x(22),
rsG2300(23),
rs416v2(24),
rsg2288(25),
rp110(26),
rs900GP(27),
rs900M(28),
rs950G(29),
rsG2488(61),
rsG2488v2(62),
rsG2488v3(63),
rmc8388A(64),
rmc8388B(65),
rmc8388C(66),
rsG920P(67),
rsMCPU(255), -- RSMCPU, otherwise known
-- as 40-00-0008 Rev B1
rx1000(256),
rx1100(257),
rx1500(258),
rx1501(259),
rx1510(260),
rx1511(261),
rx1512(262),
rx5000(263),
mx5000(264),
rx1400(265)
}
rcSysInfoConformance OBJECT IDENTIFIER ::= { rcSysInfo 5 }
-- rcSysInfoCompliances OBJECT IDENTIFIER ::= { rcSysInfoConformance 1 }
rcSysInfoGroups OBJECT IDENTIFIER ::= { rcSysInfoConformance 2 }
-- ---------------------------------------------------------------------- --
-- SysInfo subtrees
-- ---------------------------------------------------------------------- --
rcDeviceError OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main subtree for various errors detected in RuggedCom devices."
::= { rcSysInfo 1 }
rcDeviceStatus OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main subtree for various status information detected in
RuggedCom devices."
::= { rcSysInfo 2 }
rcDeviceInfo OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main subtree for RuggedCom devices manufacturing information."
::= { rcSysInfo 3 }
rcDeviceCommands OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main subtree for device control commands."
::= { rcSysInfo 4 }
-- ---------------------------------------------------------------------- --
-- Device errors objects
-- ---------------------------------------------------------------------- --
rcDeviceErrBootupError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The error discovered during bootup process.
If there was no error during device bootup, zero length string
will be retreived."
::= { rcDeviceError 1}
rcDeviceErrWatchdogReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the last device reboot was caused by wachdog."
::= { rcDeviceError 2}
rcDeviceErrConfigurationFailure OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether errors were detected while applying configuration
settings from configuration file.
Configuration is updated from the configureation file at bootup time
when file is loaded from nonvolatile memory, or when new file is
downloaded to the device.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 3}
rcDeviceErrCrashLogCreated OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the device error that caused creation of an
entry in crashlog.txt file was detected.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 4}
rcDeviceErrStackOverflow OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the stack of any of the system tasks is used
over the system threshold.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 5}
rcDeviceErrHeapError OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the system memory corruption was detected.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 6}
rcDeviceErrDateAndTimeSetFailed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the date and time setting in the device falied.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 7}
rcDeviceErrNtpServerUnreachable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether any of NTP servers (if required) can be reached.
The value of this object is 'false' if both servers become unreachable.
Whenever the value of this object changes, the device will generate
the ntpServiceAvailableChange notification."
REFERENCE
"ntpServiceAvailableChange notification is defined in RUGGEDCOM-NTP-MIB file."
::= { rcDeviceError 8 }
rcDeviceErrBootPTftpTrFailed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the the file was transfered properly after
obtaining IP address from the BootP server.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 9 }
rcDeviceErrRadiusServerUnreachable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the RADIUS server (if required) can be reached.
Whenever the value of this object changes, the device will generate
the radiusServiceAvailableChange notification."
REFERENCE
"radiusServiceAvailableChange notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 10 }
rcDeviceErrTacacsServerUnreachable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the TACACS+ server (if required) can be reached.
Whenever the value of this object changes, the device will generate
the tacacsServiceAvailableChange notification."
REFERENCE
"tacacsServiceAvailableChange notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 11 }
rcDeviceErrSystem OBJECT-TYPE
SYNTAX BITS {
errCrashLog(0),
errWatchdogRst(1),
errBootupErr(2),
errCfgFailure(3),
errStackOvfl(4),
errHeapErr(5),
errRealTimeClk(6),
errRxBuffersLow(7),
errClockManager_OutOfResources(8),
errClockManager_PrimarySourceFailed(9),
errFpgaCompatibility(10),
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicated whether a device failure occured. Whenever the value of this object
changes, the device will generate the deviceErrTrap notification."
REFERENCE
"deviceErrTrap notification is defined in ruggedcomTrapsModule."
::= {rcDeviceError 12 }
-- ---------------------------------------------------------------------- --
-- Device Status information objects
-- ---------------------------------------------------------------------- --
rcDeviceStsCpuUsage OBJECT-TYPE
SYNTAX Integer32
UNITS "tenths of percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage in tenths of percent of available CPU cycles used
for device operation as measured over the last second when
object was retreived."
::= { rcDeviceStatus 1 }
rcDeviceStsAvailableRam OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes of RAM still available in the system
control CPU."
::= { rcDeviceStatus 2 }
rcDeviceStsTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature measured in the device."
::= { rcDeviceStatus 3 }
rcDeviceStsPowerSupply1 OBJECT-TYPE
SYNTAX RcHardwareStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of Power Supply Module 1.
Whenever the value of this object changes from functional(2) to
notFunctional(3), or from notFunctionl(3) to functional(2),
the device will generate powerSupplyTrap notification."
REFERENCE
"powerSupplyTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 4 }
rcDeviceStsPowerSupply2 OBJECT-TYPE
SYNTAX RcHardwareStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of Power Supply Module 2.
Whenever the value of this object changes from functional(2) to
notFunctional(3), or from notFunctionl(3) to functional(2),
the device will generate powerSupplyTrap notification."
REFERENCE
"powerSupplyTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 5 }
rcDeviceStsCpuUsagePercent OBJECT-TYPE
SYNTAX Integer32
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of available CPU cycles used for device operation
as measured over the last second when object was retreived."
::= { rcDeviceStatus 6 }
rcDeviceStsFailSafeRelay OBJECT-TYPE
SYNTAX INTEGER {
energized(1),
deEnergized(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates status of fail safe relay in the device.
Fail safe relay is deEnergized(2) if there is at least one active
alarm recorded in the device."
::= { rcDeviceStatus 7 }
rcDeviceStsErrorAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates that at least one alarm of level ERROR, ALERT or CRITICAL
is active in the device."
::= { rcDeviceStatus 8 }
rcDeviceStsNoOfActiveAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of active alarms currently recorded in device."
::= { rcDeviceStatus 9 }
rcDeviceStsFanBank1 OBJECT-TYPE
SYNTAX RcFanStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of Fan Bank Module 1."
REFERENCE
"fanBankTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 10 }
rcDeviceStsFanBank2 OBJECT-TYPE
SYNTAX RcFanStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of Fan Bank Module 2."
REFERENCE
"fanBankTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 11 }
rcDeviceStsPwdsWeak OBJECT-TYPE
SYNTAX BITS {
adminPwd(0),
operPwd(1),
guestPwd(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if any of passwords is configured as 'weak'.
Change in the value of the bit in this object from '0' to '1'
will generate weakPasswordTrap."
REFERENCE
"weakPasswordTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 12 }
rcDeviceStsKeysDflt OBJECT-TYPE
SYNTAX BITS {
sshDfltKeys(0),
sslDfltKeys(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if any of secure services uses default keys and/or
certificates. Customer is advised to update keys for secure
services if defaults are used.
Change in the value of the bit in this object from '0' to '1'
will generate defaultKeysTrap notification."
REFERENCE
"defaultKeysTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 13 }
-- ---------------------------------------------------------------------- --
-- General System Information objects
-- ---------------------------------------------------------------------- --
rcDeviceInfoSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturing serial number of the device."
::= { rcDeviceInfo 1 }
rcDeviceInfoBootSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version and the build date of the boot loader software."
::= { rcDeviceInfo 2 }
rcDeviceInfoMainSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version and the build date of the main operating system
software."
::= { rcDeviceInfo 3 }
rcDeviceInfoMainBoardType OBJECT-TYPE
SYNTAX RcMainBoard
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The identification code of the device main board."
::= { rcDeviceInfo 4 }
rcDeviceInfoTotalRam OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes of RAM in the system control CPU."
::= { rcDeviceInfo 5 }
rcDeviceInfoPendingBootSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version and the build date of the boot loader software
that has been loaded to the device and is pending reboot.
Whenever the value of this object changes from zero-length string
to any string of non-zero length, the device will generate
swUpgradeTrap notification."
REFERENCE
"swUpgradeTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceInfo 6 }
rcDeviceInfoPendingMainSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version and the build date of the main operating system
software that has been loaded to the device and is pending reboot.
Whenever the value of this object changes from zero-length string
to any string of non-zero length, the device will generate
swUpgradeTrap notification."
REFERENCE
"swUpgradeTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceInfo 7 }
rcDeviceInfoCfgRevision OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configuration file revision.
The revision number will be updated whenever file is saved to the
flash memory. This number is recorded in config.csv at the time file
is uploaded from the device.
Whenever the value of this object changes the device will generate
cfgChangeTrap notification."
REFERENCE
"cfgChangeTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceInfo 8 }
rcDeviceInfoMinBootSwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum version of the boot loader software required by
ROS device. If this version is not newer than the version
retreived as a value of object rcDeviceInfoBootSwVersion, trap
bootVersionMismatchTrap will be generated."
REFERENCE
"bootVersionMismatchTrap notification is defined in
ruggedcomTrapsModule."
::= { rcDeviceInfo 9 }
-- ---------------------------------------------------------------------- --
-- Device control commands objects
-- ---------------------------------------------------------------------- --
rcDeviceCommReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will cause device
to reboot.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 1}
rcDeviceCommLoadDefaultCfg OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will force device
to load default configuration to all tables.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 2}
rcDeviceCommClearAlarms OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will cause device
to clear all alarms.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 3}
rcDeviceCommClearSyslog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will cause device
to clear syslog.txt file.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 4}
rcDeviceCommClearLogs OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will cause device
to clear syslog.txt and crashlog.txt files.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 5}
rcDeviceCommIdentify OBJECT-TYPE
SYNTAX Integer32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time Period in seconds for which the device should continue flashing
the LEDs when possible so that device is visually recognized.
Setting this value to any value greater than 0 will start LED flash
timer on the device.Setting the value to 0 will stop the LED flash
timer. On Read request agent always sends back the existing Timeout
value for LED flash Timer."
::= { rcDeviceCommands 6 }
-- ---------------------------------------------------------------------- --
-- Object Groups
-- ---------------------------------------------------------------------- --
rcSysErrObjectsGroup OBJECT-GROUP
OBJECTS {
rcDeviceErrBootupError,
rcDeviceErrWatchdogReset,
rcDeviceErrConfigurationFailure,
rcDeviceErrCrashLogCreated,
rcDeviceErrStackOverflow,
rcDeviceErrHeapError,
rcDeviceErrDateAndTimeSetFailed,
rcDeviceErrNtpServerUnreachable,
rcDeviceErrBootPTftpTrFailed,
rcDeviceErrRadiusServerUnreachable,
rcDeviceErrTacacsServerUnreachable
}
STATUS obsolete
DESCRIPTION
"A group of objects providing information about irregularities
in the device."
::= { rcSysInfoGroups 1 }
rcSysStsObjectsGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsCpuUsage,
rcDeviceStsCpuUsagePercent,
rcDeviceStsAvailableRam
}
STATUS obsolete
DESCRIPTION
"A group of objects providing information device resources."
::= { rcSysInfoGroups 2 }
rcSysStsObjectsTemperatureGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsTemperature
}
STATUS current
DESCRIPTION
"This group is created to allow MIBs for products that do not have
temperature sensore installed to exclude rcDeviceStsTemperature
object."
::= { rcSysInfoGroups 3 }
rcSysStsPowerSupplyGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsPowerSupply1,
rcDeviceStsPowerSupply2
}
STATUS current
DESCRIPTION
"A group of objects providing information about power supply modules
in the device. This group is mandatory for products with redundant
power supply."
::= { rcSysInfoGroups 4 }
rcSysInfoDeviceInfoGroup OBJECT-GROUP
OBJECTS {
rcDeviceInfoMainBoardType,
rcDeviceInfoTotalRam,
rcDeviceInfoBootSwVersion,
rcDeviceInfoMainSwVersion,
rcDeviceInfoPendingBootSwVersion,
rcDeviceInfoPendingMainSwVersion,
rcDeviceInfoCfgRevision,
rcDeviceInfoSerialNumber
}
STATUS current
DESCRIPTION
"A group of object providing manufacturer's information about
product's main board hardware, software, identification."
::= { rcSysInfoGroups 5 }
rcSysDeviceCommGroup OBJECT-GROUP
OBJECTS {
rcDeviceCommReset,
rcDeviceCommLoadDefaultCfg,
rcDeviceCommClearAlarms,
rcDeviceCommClearSyslog,
rcDeviceCommClearLogs
}
STATUS current
DESCRIPTION
"A group of object providing device control commands."
::= { rcSysInfoGroups 6 }
rcSysDeviceCommIdentifyGroup OBJECT-GROUP
OBJECTS {
rcDeviceCommIdentify
}
STATUS current
DESCRIPTION
"A group of object providing device control commands for
visual recognisation of the device (LED flashing)."
::= { rcSysInfoGroups 7 }
rcSysStsObjectsGroup1 OBJECT-GROUP
OBJECTS {
rcDeviceStsCpuUsage,
rcDeviceStsCpuUsagePercent,
rcDeviceStsAvailableRam,
rcDeviceStsErrorAlarm,
rcDeviceStsFailSafeRelay,
rcDeviceStsNoOfActiveAlarms
}
STATUS current
DESCRIPTION
"A group of objects providing information about device resources."
::= { rcSysInfoGroups 8 }
rcSysStsFanBankGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsFanBank1,
rcDeviceStsFanBank2
}
STATUS current
DESCRIPTION
"A group of objects providing information about fan bank modules
in the device. This group is mandatory for products with redundant
fan banks."
::= { rcSysInfoGroups 9 }
rcSysDeviceSecurityGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsPwdsWeak
}
STATUS current
DESCRIPTION
"A group of object providing device control commands."
::= { rcSysInfoGroups 10 }
rcSysDeviceSecurityGroup01 OBJECT-GROUP
OBJECTS {
rcDeviceStsPwdsWeak,
rcDeviceStsKeysDflt,
rcDeviceInfoMinBootSwVer
}
STATUS current
DESCRIPTION
"A group of object providing device control commands."
::= { rcSysInfoGroups 11 }
rcSysErrObjectsGroup1 OBJECT-GROUP
OBJECTS {
rcDeviceErrSystem
}
STATUS current
DESCRIPTION
"A group of objects providing information about device system errors."
::= { rcSysInfoGroups 12 }
END
|