1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
|
-- *****************************************************************
-- SENSATRONICS-ITTM.TXT: MIB corresponding to ITTM firmware v3.0
--
-- February 2004 Andrew F. Thompson--
-- Copyright (c) 2004 by Sensatronics LLC
-- All rights reserved.--
-- *****************************************************************
SENSATRONICS-EM1 DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
IpAddress,
TimeTicks
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
envMonitors
FROM SENSATRONICS-SMI;
productEM1 MODULE-IDENTITY
LAST-UPDATED "200409130900Z"
ORGANIZATION "Sensatronics LLC"
CONTACT-INFO
"Sensatronics LLC
Postal: 20A Dunklee Road
Bow, NH 03304
USA
Tel: +1 603 224 0617
E-mail: dthompson@sensatronics.com"
DESCRIPTION
"Description of EM1 code."
REVISION "200409130900Z"
DESCRIPTION
"Initial version of this MIB module."
::= { envMonitors 3 }
unitInfo OBJECT IDENTIFIER ::= { productEM1 1 } -- Unit info for the Temperature Monitor being accessed.
configData OBJECT IDENTIFIER ::= { productEM1 2 } -- Config data for the Temperature Monitor being accessed.
sensorInfo OBJECT IDENTIFIER ::= { productEM1 3 } -- Sensor data for the Temperature Monitor being accessed.
unitName OBJECT-TYPE
SYNTAX DisplayString (SIZE (32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user-definable unit name for the module being managed."
::= { unitInfo 1 }
unitModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The model number of the module being managed."
::= { unitInfo 2 }
unitManufacturer OBJECT-TYPE
SYNTAX DisplayString (SIZE (12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Company name of unit producer."
::= { unitInfo 3 }
unitWeb OBJECT-TYPE
SYNTAX DisplayString (SIZE (28))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Website of manufacturer"
::= { unitInfo 4 }
unitFirmware OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Firmware revision of unit."
::= { unitInfo 5 }
unitFWReleaseDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (18))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Release date of unit firmware."
::= { unitInfo 6 }
unitSerial OBJECT-TYPE
SYNTAX DisplayString (SIZE (32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of unit being managed."
::= { unitInfo 7 }
unitConfig OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In-house configuration MIB - do not use."
::= { unitInfo 8 }
netInfo OBJECT IDENTIFIER ::= { configData 1 } -- Network info for unit
trapConfig OBJECT IDENTIFIER ::= { configData 2 } -- Trap setup for unit
measurementSystem OBJECT IDENTIFIER ::= { configData 3 } -- Configuration of system of units
netMode OBJECT-TYPE
SYNTAX
INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1 if the unit is self-configuring via DHCP, 0 if static IP assigned."
::= { netInfo 1 }
netIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP address of unit being managed."
::= { netInfo 2 }
netNM OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Netmask of unit being managed."
::= { netInfo 3 }
netGW OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gateway of unit being managed."
::= { netInfo 4 }
netHTTPPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port the unit webserver listens on"
::= { netInfo 5 }
managerConfig OBJECT IDENTIFIER ::= { trapConfig 1 } -- Trap manager setup for unit
unitMode OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set to C for Celsius units in probe data, F for Fahrenheit,
K for Kelvin, R for Rankine, other values disallowed."
::= { measurementSystem 1 }
managerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP of trap manager."
::= { managerConfig 1 }
group1 OBJECT IDENTIFIER ::= { sensorInfo 1 } -- 4 groups
group2 OBJECT IDENTIFIER ::= { sensorInfo 2 }
group3 OBJECT IDENTIFIER ::= { sensorInfo 3 }
group4 OBJECT IDENTIFIER ::= { sensorInfo 4 }
group1Name OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of group 1 - User configurable, 16 characters"
::= { group1 1 }
group1TempName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Temperature probe in group 1 - User configurable, 16 characters"
::= { group1 2 }
group1TempDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Temperature probe in group 1, string format, to 1 decimal place"
::= { group1 3 }
group1TempDataInt OBJECT-TYPE
SYNTAX INTEGER (-1000..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Temperature probe in group 1, integer format, no decimal places"
::= { group1 4 }
group1HumidName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Humidity probe in group 1 - User configurable, 16 characters"
::= { group1 5 }
group1HumidDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Humidity probe in group 1, string format, to 1 decimal place"
::= { group1 6 }
group1HumidDataInt OBJECT-TYPE
SYNTAX INTEGER (0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Humidity probe in group 1, integer format, no decimal places"
::= { group1 7 }
group1WetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Wetness probe in group 1 - User configurable, 16 characters"
::= { group1 8 }
group1WetDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Wetness probe in group 1, string format, to 1 decimal place"
::= { group1 9 }
group1WetDataInt OBJECT-TYPE
SYNTAX INTEGER (-1..110)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Wetness probe in group 1, integer format, no decimal places"
::= { group1 10 }
group2Name OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of group 2 - User configurable, 16 characters"
::= { group2 1 }
group2TempName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Temperature probe in group 2 - User configurable, 16 characters"
::= { group2 2 }
group2TempDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Temperature probe in group 2, string format, to 1 decimal place"
::= { group2 3 }
group2TempDataInt OBJECT-TYPE
SYNTAX INTEGER (-1000..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Temperature probe in group 2, integer format, no decimal places"
::= { group2 4 }
group2HumidName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Humidity probe in group 2 - User configurable, 16 characters"
::= { group2 5 }
group2HumidDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Humidity probe in group 2, string format, to 1 decimal place"
::= { group2 6 }
group2HumidDataInt OBJECT-TYPE
SYNTAX INTEGER (0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Humidity probe in group 2, integer format, no decimal places"
::= { group2 7 }
group2WetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Wetness probe in group 2 - User configurable, 16 characters"
::= { group2 8 }
group2WetDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Wetness probe in group 2, string format, to 1 decimal place"
::= { group2 9 }
group2WetDataInt OBJECT-TYPE
SYNTAX INTEGER (-1..110)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Wetness probe in group 2, integer format, no decimal places"
::= { group2 10 }
group3Name OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of group 3 - User configurable, 16 characters"
::= { group3 1 }
group3TempName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Temperature probe in group 3 - User configurable, 16 characters"
::= { group3 2 }
group3TempDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Temperature probe in group 3, string format, to 1 decimal place"
::= { group3 3 }
group3TempDataInt OBJECT-TYPE
SYNTAX INTEGER (-1000..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Temperature probe in group 3, integer format, no decimal places"
::= { group3 4 }
group3HumidName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Humidity probe in group 3 - User configurable, 16 characters"
::= { group3 5 }
group3HumidDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Humidity probe in group 3, string format, to 1 decimal place"
::= { group3 6 }
group3HumidDataInt OBJECT-TYPE
SYNTAX INTEGER (0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Humidity probe in group 3, integer format, no decimal places"
::= { group3 7 }
group3WetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Wetness probe in group 3 - User configurable, 16 characters"
::= { group3 8 }
group3WetDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Wetness probe in group 3, string format, to 1 decimal place"
::= { group3 9 }
group3WetDataInt OBJECT-TYPE
SYNTAX INTEGER (-1..110)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Wetness probe in group 3, integer format, no decimal places"
::= { group3 10 }
group4Name OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of group 4 - User configurable, 16 characters"
::= { group4 1 }
group4TempName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Temperature probe in group 4 - User configurable, 16 characters"
::= { group4 2 }
group4TempDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Temperature probe in group 4, string format, to 1 decimal place"
::= { group4 3 }
group4TempDataInt OBJECT-TYPE
SYNTAX INTEGER (-1000..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Temperature probe in group 4, integer format, no decimal places"
::= { group4 4 }
group4HumidName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Humidity probe in group 4 - User configurable, 16 characters"
::= { group4 5 }
group4HumidDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Humidity probe in group 4, string format, to 1 decimal place"
::= { group4 6 }
group4HumidDataInt OBJECT-TYPE
SYNTAX INTEGER (0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Humidity probe in group 4, integer format, no decimal places"
::= { group4 7 }
group4WetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of Wetness probe in group 4 - User configurable, 16 characters"
::= { group4 8 }
group4WetDataStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Wetness probe in group 4, string format, to 1 decimal place"
::= { group4 9 }
group4WetDataInt OBJECT-TYPE
SYNTAX INTEGER (-1..110)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data from Wetness probe in group 4, integer format, no decimal places"
::= { group4 10 }
END
|