summaryrefslogtreecommitdiff
path: root/MIBS/siae/SIAE-EQUIP-MIB
blob: 42e0f6824b5b1766bc01083b6eadec2577cd67ff (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
-- ----------------------------------------------------------------------------
--
--  SIAE MICROELETTRONICA s.p.a.
--                 
--  Via Michelangelo Buonarroti, 21
--  20093 - Cologno Monzese
--  Milano 
--  ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------

SIAE-EQUIP-MIB
        DEFINITIONS ::= BEGIN

        IMPORTS
             MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
             Integer32, IpAddress, TimeTicks
        FROM SNMPv2-SMI
             DisplayString, AutonomousType
        FROM SNMPv2-TC
             InterfaceIndex
        FROM IF-MIB
             siaeMib
        FROM SIAE-TREE-MIB
             AlarmStatus, AlarmSeverityCode, alarmTrap
        FROM SIAE-ALARM-MIB
             equipTypeUnknown
        FROM SIAE-EQUIPTYPE-MIB;
           
    equipment MODULE-IDENTITY
        LAST-UPDATED "201503230000Z"
        ORGANIZATION "SIAE MICROELETTRONICA spa"
        CONTACT-INFO
            "SIAE MICROELETTONICA s.p.a.
             Via Michelangelo Buonarroti, 21
             20093 - Cologno Monzese
             Milano - ITALY
             Phone :  +39-02-27325-1
             E-mail: help@siaemic.com
            "
        DESCRIPTION
            "Common parameters of SIAE equipments.
            "
        REVISION "201503230000Z"
        DESCRIPTION
            "Removed alarmTrapNumber from TRAPs and IMPORTS.
            "
        REVISION "201412030000Z"
        DESCRIPTION
            "MIB version 01.00.02
             Added equipIpEthDefGatewayIfIndex
            "
        REVISION "201407010000Z"
        DESCRIPTION
            "MIB version 01.00.01
             Added equipIpEthVlanId and equipIpEthDefGateway
            "
        REVISION "201406230000Z"
        DESCRIPTION
            "Fixed IMPORTS clause
            "
        REVISION "201402030000Z"
        DESCRIPTION
            "Improved description of equipMibVersion
            "
        REVISION "201304160000Z"
        DESCRIPTION 
            "Initial version 01.00.00
            "
    ::= { siaeMib 1 }

----------------------------------------------------------------------------------
--  SIAE equipment GROUP
----------------------------------------------------------------------------------
--
--  The following listed objects are general object common to all SIAE equipment.
--
----------------------------------------------------------------------------------

------ Beginning --------------------------------------------------------------


    equipMibVersion  OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Numerical version of this module.
             The string version of this MIB have the following format:
                XX.YY.ZZ
             so, for example, the value 1 should be interpreted as 00.00.01
             and the value 10001 should be interpreted as 01.00.01."
        DEFVAL {1}
    ::= {equipment 1}

    equipCurrentTime  OBJECT-TYPE
        SYNTAX      TimeTicks
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Seconds since 1/1/1970."
    ::= {equipment 2}

    equipUpTime  OBJECT-TYPE
        SYNTAX      TimeTicks
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The time since the system was last re-initialized (in seconds
             since 1/1/1970)."
    ::= {equipment 3}

    equipType  OBJECT-TYPE
        SYNTAX      AutonomousType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Type of SIAE MICROELETTRONICA's equipment"
        DEFVAL { equipTypeUnknown }
    ::= {equipment 4}

    -- OBJECT-IDENTIFIER {equipment 5} is used in sm_equiptype.mib

    equipIpEthOsiAddress  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Ip address of the equipment on Ethernet-OSI interface."
    ::= {equipment 6}

    equipGosipAddress  OBJECT-TYPE
        SYNTAX      OCTET STRING    (SIZE(0..20))
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "GOSIP address of the equipment."
    ::= {equipment 7}

    equipIpEthOsiNetMask  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The subnet Mask associated with the IP address of OSI ethernet interface.
             The value of the Mask is an IP address with all the network bits set to 1
             and all the hosts bits set to 0."
    ::= {equipment 8}

    equipL1L2IsIsRouting  OBJECT-TYPE
        SYNTAX      INTEGER {
                             l1  (1),
                             l2  (2)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "It defines the IS-IS routing type: L1 within the same area, L2 among
             different areas."
        DEFVAL {l1}
    ::= {equipment 9}

    equipStationID  OBJECT-TYPE
        SYNTAX      DisplayString    (SIZE(0..63))
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "ASCII string assigned by the operator to identify the specific equipment."
    ::= {equipment 10}

    equipLOMConfigEnable  OBJECT-TYPE
        SYNTAX      INTEGER {
                             disable  (1),
                             enable   (2)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Enables/disables the capabilityto connect a LOM in Configuration Mode."
    ::= {equipment 11}

    equipLOMConnected  OBJECT-TYPE
        SYNTAX      INTEGER {
                             cleared              (1),
                             connectionAsMonitor  (2),
                             connectionAsConfig   (3)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Signal when the LOM is connected to the NE and if the connection
             is for monitor or configuration."
    ::= {equipment 12}

    equipLOMConnectedTrapEnable  OBJECT-TYPE
        SYNTAX      INTEGER {
                             trapDisable        (1),
                             trapEnable         (2),
                             trapEnableWithAck  (3)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Enables/disables the trap generation on EquipLOMConnected status change event."
        DEFVAL {trapEnable}
    ::= {equipment 13}

    equipConfigChange  OBJECT-TYPE
        SYNTAX      OCTET STRING    (SIZE(6))
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Set by the NE when the equipment configuration is changed by the local
             or Remote LOM.
             The octet string is a bit stream of flags; a set bit is a change on a
             specific item. We had:
             Byte 0.7: change in configuration for equipment group
             Byte 0.6: change in configuration for userInput group
             Byte 0.5: change in configuration for userOutput group
             Byte 0.4: change in configuration for alarmLog group
             ......
             Byte 3.7: change in a severity for equipment group
             Byte 3.6: change in a severity for userInput group
             Byte 3.5: change in a severity for userOutput group
             Byte 3.4: change in a severity for alarmLog group
             CEM can reset the change condition writing one to desired bit flag
             ......"
    ::= {equipment 14}

    equipConfigChangeTrapEnable  OBJECT-TYPE
        SYNTAX      INTEGER {
                             trapDisable        (1),
                             trapEnable         (2),
                             trapEnableWithACK  (3)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Enables/disables the trap generation on EquipConfigChange status
             change event."
        DEFVAL {trapEnable}
    ::= {equipment 15}

    equipRequest  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive              (0), -- no write-only in v2
                             restart                (1),
                             applyIfChange          (2),
                             revertIfChange         (3),
                             configClearAndRestart  (4),
                             routeTableClear        (5),
                             uploadBaseBand         (6),
                             offLineRouteRetrieve   (7),
                             offLineRouteSave       (8),
                             hotApplyIfChange       (11),
                             ipStackConfigure       (20),
                             osiStackConfigure      (21),
                             atuTableReset          (50),
                             siaeReservedReq1       (100),
                             siaeReservedReq26      (125),
                             siaeReservedReq27      (126),
                             switchFactoryDefault   (127)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Force Equipment Controller restart or change in interface properties."
    ::= {equipment 16}

    equipIpEthAddress  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Ip address of the equipment on Ethernet interface."
    ::= {equipment 17}

    equipIpEthNetMask  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The subnet Mask associated with the IP address of ethernet interface.
             The value of the Mask is an IP address with all the network bits set to 1
             and all the hosts bits set to 0."
    ::= {equipment 18}

    equipOsiamParameter  OBJECT-TYPE
        SYNTAX      OCTET STRING (SIZE(0..41))
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "It defines the set-up parameter for OSI stack."
    ::= {equipment 19}

    equipIpSnmpAgentAddress  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Ip address used by SNMP Agent for mark generated TRAP."
    ::= {equipment 20}

    equipOperationInProgress  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "A value different from 0 means operation in progress."
        DEFVAL {0}
    ::= {equipment 21}

    equipManagerWakeUpAlarm  OBJECT-TYPE
       SYNTAX       AlarmStatus
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
           "This alarm switches on when periodic connection wake-up trap starts.
            The trap related to this alarm is also sent periodically only to the
            manager specified by the leaf equipManagerWakeUpIpAddr when
            equipManagerWakeUpAlarmSeverityCode differs from disable."
    ::= {equipment 22}

    equipManagerWakeUpAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Defines the severity associated to the equipManagerWakeUpAlarm
             and enables/disables the trap generation on status change event."
        DEFVAL {disable}
    ::= {equipment 23}

    equipManagerWakeUpTimeout  OBJECT-TYPE
        SYNTAX      INTEGER    (0..1440)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the time (in minutes) after which the periodic
             connection wake-up trap is stopped.
             The maximium value is equivalent to 24 hours.
             When the timeout elapses the equipManagerWakeUpAlarmSeverityCode
             is set to disable.
             A zero means no timeout."
        DEFVAL {60}
    ::= {equipment 24}

    equipManagerWakeUpIpAddr  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Ip Address of manager wich to send a periodic connection wake-up trap.
             The periodic trap is sent only if the equipManagerWakeUpAlarmSeverityCode
             differs from disable.
             If Ip Address equals 0 no trap will be sent."
        DEFVAL {'00'H}
    ::= {equipment 25}

    equipManagerWakeUpGosipAddress  OBJECT-TYPE
        SYNTAX      OCTET STRING    (SIZE(0..20))
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Gosip Address of manager wich to send a periodic connection wake-up trap."
    ::= {equipment 26}

    equipManagerWakeUpTrapVersion  OBJECT-TYPE
        SYNTAX      INTEGER {
                              trapV1  (1),
                              trapV2  (2),
                              trapV3  (3)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Trap version supported by Manager to wake-up."
        DEFVAL {trapV1}
    ::= {equipment 27}

    equipManager1IpAddr  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "First IP address of a SNMP Manager always logged to this equipment.
             The address 0.0.0.0 mean that manager is not present."
    ::= {equipment 28}

    equipManager2IpAddr  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Second IP address of a SNMP Manager always logged to this equipment.
             The address 0.0.0.0 mean that manager is not present."
    ::= {equipment 29}

    equipManager1TrapVersion  OBJECT-TYPE
        SYNTAX      INTEGER {
                             trapV1  (1),
                             trapV2  (2),
                             trapV3  (3)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Trap version supported by Manager 1 (related to equipManager1IpAddr)."
        DEFVAL {trapV1}
    ::= {equipment 30}

    equipManager2TrapVersion  OBJECT-TYPE
        SYNTAX      INTEGER {
                             trapV1  (1),
                             trapV2  (2),
                             trapV3  (3)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Trap version supported by Manager 2 (related to equipManager2IpAddr)."
        DEFVAL {trapV1}
    ::= {equipment 31}

    equipDailyPmTimeZone  OBJECT-TYPE
        SYNTAX      INTEGER    (-12..12)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Reference GMT Time Zone to close the daily P.M. records."
        DEFVAL {0}
    ::= {equipment 32}

   equipOperationMngtControl OBJECT-TYPE
       SYNTAX      INTEGER {
                             notActive         (0), -- no write-only in v2
                             startOperation    (1),
                             confirmOperation  (2)
                           }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "startOperation means the apply of the 'management parameters
            set' on the E6165 switch.
            confirmOperation means the backup of the 'management
            parameters set'."
       DEFVAL {0}
   ::= {equipment 33}

   equipOperationMngtInProgress OBJECT-TYPE
       SYNTAX      INTEGER
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "A value different from 0 means Mngt operation in progress."
   ::= {equipment 34}

   equipLocation  OBJECT-TYPE
       SYNTAX      DisplayString   (SIZE(0..31))
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "ASCII string assigned by the operator to identify the location of
            specific equipment."
   ::= {equipment 35}

   equipLongitude OBJECT-TYPE
       SYNTAX      INTEGER
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "Geographic coordinate that specifies the east-west position of
            the equipment.
            In order to calculate the latitude in degrees the formula to be
            applied is
               Longitude = equipLongitude*180/2^31
            This object is used with equipLatitude to locate the equipment
            on a map.
           "
   ::= {equipment 36}

   equipLatitude OBJECT-TYPE
       SYNTAX      INTEGER
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "Geographic coordinate that specifies the north-south position of
            the equipment.
            In order to calculate the latitude in degrees the formula to be
            applied is
               Latitude = equipLatitude*180/2^31
            This object is used with equipLongitude to locate the equipment
            on a map.
           "
   ::= {equipment 37}

    equipIpEthVlanId  OBJECT-TYPE
       SYNTAX      Integer32 (1..4094)
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
          "Ethernet vlan id on top of which management is built"
           DEFVAL  { 1 }
       ::= { equipment 38 }

    equipIpEthDefGateway  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Ip address of the default gateway on Ethernet interface."
    ::= {equipment 39}

    equipIpEthDefGatewayIfIndex  OBJECT-TYPE
        SYNTAX      InterfaceIndex(1..999)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Ip address of the default gateway on Ethernet interface."
    ::= {equipment 40}

-----------------------
--
--  The equipment Group generates the following TRAPs:
--
-----------------------
    equipLOMConnectedMonitor  NOTIFICATION-TYPE
        OBJECTS  {equipIpSnmpAgentAddress, equipLOMConnected}
        STATUS current
        DESCRIPTION
            "This event is generated by ALFOHD-NE when equipLOMConnected is set to Monitor mode.
             The data passed with the event are:
                1) equipIpSnmpAgentAddress
                2) equipLOMConnected"
    ::= {alarmTrap 109}

    equipLOMConnectedConfig  NOTIFICATION-TYPE
        OBJECTS  {equipIpSnmpAgentAddress, equipLOMConnected}
        STATUS current
        DESCRIPTION
            "This event is generated by ALFOHD-NE when equipLOMConnected is set to Configuration mode.
             The data passed with the event are:
                1) equipIpSnmpAgentAddress
                2) equipLOMConnected"
    ::= {alarmTrap 110}

    equipLOMDisconnected  NOTIFICATION-TYPE
        OBJECTS  {equipIpSnmpAgentAddress, equipLOMConnected}
        STATUS current
        DESCRIPTION
            "This event is generated by ALFOHD-NE when LOMConnected is cleared.
             The data passed with the event are:
                1) equipIpSnmpAgentAddress
                2) equipLOMConnected"
    ::= {alarmTrap 111}


    equipConfigChangeStatus  NOTIFICATION-TYPE
        OBJECTS  {equipIpSnmpAgentAddress, equipConfigChange}
        STATUS current
        DESCRIPTION
            "This event is generated by ALFOHD-NE when equipConfigChange is changed.
             The data passed with the event are:
                1) equipIpSnmpAgentAddress
                2) equipConfigChange"
    ::= {alarmTrap 114}

    equipManagerWakeUpNotify  NOTIFICATION-TYPE
        OBJECTS {equipIpSnmpAgentAddress, equipStationID, equipLocation, equipIpSnmpAgentAddress, equipGosipAddress,
                 equipManagerWakeUpIpAddr, equipManagerWakeUpAlarm}
        STATUS current
        DESCRIPTION
            " This trap is sent periodically only to the manager specified by
             the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode
             differs from disable.
             The data passed with the event are:
                1) equipIpSnmpAgentAddress
                2) equipStationID
                3) equipLocation
                4) equipIpSnmpAgentAddress
                5) equipGosipAddress
                6) equipManagerWakeUpIpAddr
                7) equipManagerWakeUpAlarm"
    ::= {alarmTrap 123}

------ End group -----------------------------------------------------------------