summaryrefslogtreecommitdiff
path: root/MIBS/siae/SIAE-PMTXPWR-MIB
blob: 5d6bde8d97d5e14454783ff86502675fd18c406e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
-- ----------------------------------------------------------------------------
--
--  SIAE MICROELETTRONICA s.p.a.
--                 
--  Via Michelangelo Buonarroti, 21
--  20093 - Cologno Monzese
--  Milano 
--  ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------

SIAE-PMTXPWR-MIB
        DEFINITIONS ::= BEGIN

        IMPORTS
             MODULE-IDENTITY, OBJECT-TYPE,
             Counter32, Integer32, Unsigned32
        FROM SNMPv2-SMI
             DisplayString, RowStatus
        FROM SNMPv2-TC
             siaeMib
        FROM SIAE-TREE-MIB
             AlarmStatus, AlarmSeverityCode
        FROM SIAE-ALARM-MIB;

    pmTxPwr MODULE-IDENTITY
        LAST-UPDATED "201410070000Z"
        ORGANIZATION "SIAE MICROELETTRONICA spa"
        CONTACT-INFO
            "SIAE MICROELETTONICA s.p.a.
             Via Michelangelo Buonarroti, 21
             20093 - Cologno Monzese
             Milano - ITALY
             Phone :  +39-02-27325-1
             E-mail: tbd@siaemic.com
            "
        DESCRIPTION
            "Performance Monitoring on Transmitted (TX) RF Power.
            "
        REVISION "201410070000Z"
        DESCRIPTION
            "Changed MAX-ACCESS caluse of some object of pmTxPwrTpClassTable
             from read-write to read-create
            "
        REVISION "201402030000Z"
        DESCRIPTION
            "Improved description of pmTxPwrMibVersion
            "
        REVISION "201304160000Z"
        DESCRIPTION 
            "Initial version 01.00.00
            "
    ::= { siaeMib 13 }

----------------------------------------------------------------------------------
--  object identifier inside the module
----------------------------------------------------------------------------------

----------------------------------------------------------------------------------
--  pmTxPwr (PERFORMANCE MONITORING TRANSMITTED POWER LEVEL) GROUP
----------------------------------------------------------------------------------
--
--  The following objects are used to manage the Transmitted Power Performance
--  Monitoring function.
--
----------------------------------------------------------------------------------

------ Beginning --------------------------------------------------------------

--
-------  The following table contains the records with the counters used to monitor
-------  the Transmitted power of the radio.
-------  Begin of pmTxPwrCounterTable
--

    pmTxPwrMibVersion  OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Numerical version of this module.
             The string version of this MIB have the following format:
                XX.YY.ZZ
             so, for example, the value 1 should be interpreted as 00.00.01
             and the value 10001 should be interpreted as 01.00.01."
        DEFVAL {1}
    ::= {pmTxPwr 1}

    pmTxPwrCounterTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF     PmTxPwrCounterRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with PmTxPwr records: one record for 1+0 configuration and two
             record for 1+1 configuration."
    ::= {pmTxPwr 2}

    pmTxPwrCounterRecord  OBJECT-TYPE
        SYNTAX      PmTxPwrCounterRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmTxPwrCounter record."
        INDEX {pmTxPwrBranchId, pmTxPwrCounterBlockId}
    ::= {pmTxPwrCounterTable 1}

    PmTxPwrCounterRecord  ::=
        SEQUENCE {
            pmTxPwrBranchId            Integer32,
            pmTxPwrCounterBlockId      Integer32,
            pmTxPwrCounterBlockType    INTEGER,
            pmTxPwrCounterBlockStatus  INTEGER,
            pmTxPwrCounterTimeStamp    Unsigned32,
            pmTxPwrTlts1Counter        Counter32,
            pmTxPwrTlts2Counter        Counter32,
            pmTxPwrTlts3Counter        Counter32,
            pmTxPwrTlts4Counter        Counter32,
            pmTxPwrTMMax               Integer32,
            pmTxPwrTMMin               Integer32,
            pmTxPwrAverageTxLevel      Integer32
        }

    pmTxPwrBranchId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies the Radio Branch"
    ::= {pmTxPwrCounterRecord 1}

    pmTxPwrCounterBlockId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies  the counters block and the counter type according to the following code:
             1   Current Daily counters
             2   Daily counters (Day before counters)
             3   Current 15 minutes counters
             4   15 minutes counters N. 1 (The most recent 15 minutes counters)
                 ..............................................
             n   15 minutes counters N. n
            19   15 minutes counters N. 16 (The oldest 15 minutes counters - 4 hours before)."
    ::= {pmTxPwrCounterRecord 2}

    pmTxPwrCounterBlockType  OBJECT-TYPE
        SYNTAX      INTEGER {
                             daily      (1),
                             fifteenMin (2)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The type of the counter block."
    ::= {pmTxPwrCounterRecord 3}

    pmTxPwrCounterBlockStatus  OBJECT-TYPE
        SYNTAX      INTEGER {
                             meaningless   (1),
                             meaningfull   (2),
                             incomplete    (3),
                             dummy         (4),
                             lost          (5),
                             restarted     (6)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "block counter status."
    ::= {pmTxPwrCounterRecord 4}

    pmTxPwrCounterTimeStamp  OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The object is the time when the performance record is closed reported
             as the second number since 1-Gen-1970."
    ::= {pmTxPwrCounterRecord 5}

    pmTxPwrTlts1Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Transmitted power is greater than the threshold 1."
    ::= {pmTxPwrCounterRecord 6}

    pmTxPwrTlts2Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Transmitted power is greater than the threshold 2"
    ::= {pmTxPwrCounterRecord 7}

    pmTxPwrTlts3Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Transmitted power is greater than the threshold 3"
    ::= {pmTxPwrCounterRecord 8}

    pmTxPwrTlts4Counter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of seconds when the Transmitted power is greater than the threshold 4"
    ::= {pmTxPwrCounterRecord 9}

    pmTxPwrTMMax  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Maximum Transmitted Power Level Tide Mark."
    ::= {pmTxPwrCounterRecord 10}

    pmTxPwrTMMin  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Minimum  Transmitted Power Level Tide Mark."
    ::= {pmTxPwrCounterRecord 11}

    pmTxPwrAverageTxLevel OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            " Power Transmitted  Level  (Average value)"
    ::=  { pmTxPwrCounterRecord 12}
--
-------  End of pmTxPwrCounterTable

--
-------  The following table contains the records used to manage the P.M. on both
-------  radio branch and the threshold cross alarms
-------  Begin of pmTxPwrTpClassTable
--
    pmTxPwrTpClassTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF     PmTxPwrTpClassRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with PmTxPwrTpClass records: one record for 1+0 configuration and two record
             for 1+1 configuration."
    ::= {pmTxPwr 3}

    pmTxPwrTpClassRecord  OBJECT-TYPE
        SYNTAX      PmTxPwrTpClassRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmTxPwrTpClass record."
        INDEX {pmTxPwrTpClassBranchId}
    ::= {pmTxPwrTpClassTable 1}

    PmTxPwrTpClassRecord  ::=
        SEQUENCE {
            pmTxPwrTpClassBranchId            Integer32,
            pmTxPwrTpClassStartStop           INTEGER,
            pmTxPwrTpClassLabel               DisplayString,
            pmTxPwrTpClassTimeStamp           Unsigned32,
            pmTxPwrTpClass15MTlts1Alarm       AlarmStatus,
            pmTxPwrTpClass15MTlts2Alarm       AlarmStatus,
            pmTxPwrTpClass15MTlts3Alarm       AlarmStatus,
            pmTxPwrTpClass15MTlts4Alarm       AlarmStatus,
            pmTxPwrTpClass24HTlts1Alarm       AlarmStatus,
            pmTxPwrTpClass24HTlts2Alarm       AlarmStatus,
            pmTxPwrTpClass24HTlts3Alarm       AlarmStatus,
            pmTxPwrTpClass24HTlts4Alarm       AlarmStatus,
            pmTxPwrTpClassTlt1Threshold       INTEGER,
            pmTxPwrTpClassTlt2Threshold       INTEGER,
            pmTxPwrTpClassTlt3Threshold       INTEGER,
            pmTxPwrTpClassTlt4Threshold       INTEGER,
            pmTxPwrTpClass15MTlts1Threshold   Integer32,
            pmTxPwrTpClass15MTlts2Threshold   Integer32,
            pmTxPwrTpClass15MTlts3Threshold   Integer32,
            pmTxPwrTpClass15MTlts4Threshold   Integer32,
            pmTxPwrTpClass24HTlts1Threshold   Integer32,
            pmTxPwrTpClass24HTlts2Threshold   Integer32,
            pmTxPwrTpClass24HTlts3Threshold   Integer32,
            pmTxPwrTpClass24HTlts4Threshold   Integer32,
            pmTxPwrTpClassRowStatus           RowStatus
        }

    pmTxPwrTpClassBranchId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies the Radio Branch"
    ::= {pmTxPwrTpClassRecord 1}

    pmTxPwrTpClassStartStop  OBJECT-TYPE
        SYNTAX      INTEGER {
                             start   (1),
                             stop    (2)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object is used to start and to stop the Perfomance Monitoring
             counter evaluation."
    ::= {pmTxPwrTpClassRecord 2}

    pmTxPwrTpClassLabel  OBJECT-TYPE
        SYNTAX      DisplayString   (SIZE(0..31))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "ASCII string used to identify the Tp class:
             pmTxPwrTpClassBranchId = 1 label = Radio 1
             pmTxPwrTpClassBranchId = 2 label = Radio 2."
    ::= {pmTxPwrTpClassRecord 3}

    pmTxPwrTpClassTimeStamp  OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The object is the time when the performance record is closed reported
             as the second number since 1/1/70."
    ::= {pmTxPwrTpClassRecord 4}

    pmTxPwrTpClass15MTlts1Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Tlts1 threshold cross alarm with associated severity."
    ::= {pmTxPwrTpClassRecord 5}

    pmTxPwrTpClass15MTlts2Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Tlts2 threshold cross alarm with associated severity."
    ::= {pmTxPwrTpClassRecord 6}

    pmTxPwrTpClass15MTlts3Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Tlts3 threshold cross alarm with associated severity."
    ::= {pmTxPwrTpClassRecord 7}

    pmTxPwrTpClass15MTlts4Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes Tlts4 threshold cross alarm with associated severity."
    ::= {pmTxPwrTpClassRecord 8}

    pmTxPwrTpClass24HTlts1Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Tlts1 threshold cross alarm with associated severity."
    ::= {pmTxPwrTpClassRecord 9}

    pmTxPwrTpClass24HTlts2Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Tlts2 threshold cross alarm with associated severity."
    ::= {pmTxPwrTpClassRecord 10}

    pmTxPwrTpClass24HTlts3Alarm  OBJECT-TYPE
        SYNTAX     AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Tlts3 threshold cross alarm with associated severity."
    ::= {pmTxPwrTpClassRecord 11}

    pmTxPwrTpClass24HTlts4Alarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily Tlts4 threshold cross alarm with associated severity."
    ::= {pmTxPwrTpClassRecord 12}

    pmTxPwrTpClassTlt1Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 1 (dBm value); range -100 to -20"
        DEFVAL {-30}
    ::= {pmTxPwrTpClassRecord 13}

    pmTxPwrTpClassTlt2Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 2 (dBm value); range -100 to -20"
        DEFVAL {-40}
    ::= {pmTxPwrTpClassRecord 14}

    pmTxPwrTpClassTlt3Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 3 (dBm value); range -100 to -20"
        DEFVAL {-50}
    ::= {pmTxPwrTpClassRecord 15}

    pmTxPwrTpClassTlt4Threshold  OBJECT-TYPE
        SYNTAX      INTEGER     (-100..-20)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Received Power Level Threshold 4 (dBm value); range -100 to -20"
        DEFVAL {-60}
    ::= {pmTxPwrTpClassRecord 16}

    pmTxPwrTpClass15MTlts1Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmTxPwrTpClass15MTlts1Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmTxPwrTpClassRecord 17}

    pmTxPwrTpClass15MTlts2Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmTxPwrTpClass15MTlts2Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmTxPwrTpClassRecord 18}

    pmTxPwrTpClass15MTlts3Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmTxPwrTpClass15MTlts3Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmTxPwrTpClassRecord 19}

    pmTxPwrTpClass15MTlts4Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within 15 minutes to set
             pmTxPwrTpClass15MTlts4Alarm (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmTxPwrTpClassRecord 20}

    pmTxPwrTpClass24HTlts1Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmTxPwrTpClass24HTlts1Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmTxPwrTpClassRecord 21}

    pmTxPwrTpClass24HTlts2Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmTxPwrTpClass24HTlts2Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmTxPwrTpClassRecord 22}

    pmTxPwrTpClass24HTlts3Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmTxPwrTpClass24HTlts3Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmTxPwrTpClassRecord 23}

    pmTxPwrTpClass24HTlts4Threshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a day to set pmTxPwrTpClass24HTlts4Alarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmTxPwrTpClassRecord 24}

    pmTxPwrTpClassRowStatus   OBJECT-TYPE 
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Status of this row of pmTxPwrTpClass.
            "
    ::= {pmTxPwrTpClassRecord 25}

--
-------   End of pmTxPwrTpClassTable

--
--  MAINTENANCE TABLE
--

-------  Begin of PmTxPwrTpMaintRecord
--
    pmTxPwrTpMaintTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF     PmTxPwrTpMaintRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with Command for maintenance of Termination Point.
             Objects in this table is not persistent. An Instance of this 
             table is created on creation of pmTxPwrTpClassTable"
    ::= {pmTxPwr 4}

    pmTxPwrTpMaintRecord  OBJECT-TYPE
        SYNTAX      PmTxPwrTpMaintRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmG828 Termination Point Maintenance record."
        INDEX {pmTxPwrTpClassBranchId}
    ::= {pmTxPwrTpMaintTable 1}

    PmTxPwrTpMaintRecord  ::=
        SEQUENCE {
            pmTxPwrTpMaintCounterClear      INTEGER,
            pmTxPwrTpMaintAlarmClear        INTEGER
        }

    pmTxPwrTpMaintCounterClear  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive   (0),
                             clear       (1)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object is used to clear the Perfomance Monitoring counters."
    ::= {pmTxPwrTpMaintRecord 1}

    pmTxPwrTpMaintAlarmClear  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive   (0),
                             clear       (1)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object is used to clear the Perfomance Monitoring threshold cross alarms."
    ::= {pmTxPwrTpMaintRecord 2}
--
-------  End of PmTxPwrTpMaintRecord

--
-------  The following objects are common to all radio branches.
--
    pmTxPwrTpClass15MTltsAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmTxPwrTpClass15MTltsAlarm
             and enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmTxPwr 5}

    pmTxPwrTpClass24HTltsAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmTxPwrTpClass24HTltsAlarm
             and enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmTxPwr 6}

------ End group -----------------------------------------------------------------

END