summaryrefslogtreecommitdiff
path: root/MIBS/solidoptics/SO-MUX-MIB
blob: d0b7f5758f470825229d26c69236c0ae53f3a2f4 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
SO-MUX-MIB DEFINITIONS ::= BEGIN

--
-- Solid Optics EDFAMUX MIB
--

IMPORTS
	MODULE-IDENTITY, enterprises, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI
	MODULE-COMPLIANCE,OBJECT-GROUP FROM SNMPv2-CONF
;

solidOptics MODULE-IDENTITY
    LAST-UPDATED "202007030000Z"
    ORGANIZATION "Solid Optics"
    CONTACT-INFO
    	"Solid Optics EU
        solid-optics.com
 
        EMail: thijs@solid-optics.eu"
    DESCRIPTION
        "This MIB contains definition of the SNMP objects
        and traps to interface with SO products."
        
    REVISION      "202007030000Z"
    DESCRIPTION
            "RFurch minor adjustments"    
                
::= { enterprises 51628 }

edfaMux	OBJECT IDENTIFIER ::= { solidOptics 1 }
--moniMux OBJECT IDENTIFIER ::= { solidOptics 2 }

---
--- EdfaMux definitions
---

dcmDistance OBJECT-TYPE
	SYNTAX Integer32(1..999)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
		"The current dispersion in kilometers."
::= {edfaMux 1}	

preEdfaSeqTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PreEdfaSeq
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
	"Table for iterator"
    ::= { edfaMux 2 }

preEdfaSeqEntry OBJECT-TYPE
	SYNTAX PreEdfaSeq
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
		"Descriptive and Status Information for the pre EDFA."
	INDEX  { preIndex }
::= {preEdfaSeqTable 1}

postEdfaSeqTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PostEdfaSeq
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
	"Table for iterator"
    ::= { edfaMux 3 }

postEdfaSeqEntry OBJECT-TYPE
	SYNTAX PostEdfaSeq
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
		"Descriptive and Status Information for the post EDFA."
	INDEX  { postIndex }
::= {postEdfaSeqTable	 1}

PreEdfaSeq	::= SEQUENCE	{
	preIndex			Integer32,
	prePowerGainValue	OCTET STRING,
	prePowerIn			OCTET STRING,
	prePowerOut			OCTET STRING,
	preTemperature		OCTET STRING
}

preIndex OBJECT-TYPE
	SYNTAX Integer32 (0..100)
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "Column index."
::= { preEdfaSeqEntry 1}

prePowerGainValue OBJECT-TYPE
	SYNTAX	OCTET STRING
	MAX-ACCESS read-only
	STATUS	current
	DESCRIPTION
	  "Gain value in dBm."
::= { preEdfaSeqEntry 2 }

prePowerIn OBJECT-TYPE
	SYNTAX	OCTET STRING
	MAX-ACCESS read-only
	STATUS	current
	DESCRIPTION
	  "Power in in dBm"
::= { preEdfaSeqEntry 3 }

prePowerOut OBJECT-TYPE
	SYNTAX	OCTET STRING
	MAX-ACCESS read-only
	STATUS	current
	DESCRIPTION
	  "Power out in dBm."
::= { preEdfaSeqEntry 4 }


preTemperature OBJECT-TYPE
	SYNTAX	OCTET STRING
	MAX-ACCESS read-only
	STATUS	current
	DESCRIPTION
	  "Current temperature in degrees Celsius."
::= { preEdfaSeqEntry 5 }

PostEdfaSeq	::= SEQUENCE	{
	postIndex			Integer32,
	postPowerGainValue	OCTET STRING,
	postPowerIn			OCTET STRING,
	postPowerOut		OCTET STRING,
	postTemperature		OCTET STRING
}

postIndex OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Column index."
::= { postEdfaSeqEntry 1}

postPowerGainValue OBJECT-TYPE
	SYNTAX	OCTET STRING
	MAX-ACCESS read-only
	STATUS	current
	DESCRIPTION
	  "Gain value in dBm."
::= { postEdfaSeqEntry 2 }

postPowerIn OBJECT-TYPE
	SYNTAX	OCTET STRING
	MAX-ACCESS read-only
	STATUS	current
	DESCRIPTION
	  "Power in in dBm"
::= { postEdfaSeqEntry 3 }

postPowerOut OBJECT-TYPE
	SYNTAX	OCTET STRING
	MAX-ACCESS read-only
	STATUS	current
	DESCRIPTION
	  "Power out in dBm."
::= { postEdfaSeqEntry 4 }


postTemperature OBJECT-TYPE
	SYNTAX	OCTET STRING
	MAX-ACCESS read-only
	STATUS	current
	DESCRIPTION
	  "Current temperature in degrees Celsius."
::= { postEdfaSeqEntry 5 }

-- conformance information

edfaConformance OBJECT IDENTIFIER ::= { edfaMux 4 }

edfaGroups      OBJECT IDENTIFIER ::= { edfaConformance 1 }
edfaCompliances OBJECT IDENTIFIER ::= { edfaConformance 2 }

-- compliance statements


edfaCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for SNMP  SolidOptics EDFA devices"

    MODULE  -- this module
        MANDATORY-GROUPS { edfaGroup }

-- here we can add optional groups!
--	GROUP       edfaGroup
--        DESCRIPTION
--            "All EDFA values must be in this group"

    ::= { edfaCompliances 1 }


-- units of conformance

-- groups 

edfaGroup    OBJECT-GROUP
    OBJECTS { 
    dcmDistance, prePowerGainValue, prePowerIn, prePowerOut, preTemperature,
    postPowerGainValue, postPowerIn, postPowerOut, postTemperature
	}
    STATUS  current
    DESCRIPTION
            "A collection of objects"
    ::= { edfaGroups 1 }

END