1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
|
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-RESILIENT-LINK-MIB.mib
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
--
PRVT-RESILIENT-LINK-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE FROM SNMPv2-SMI
NOTIFICATION-GROUP FROM SNMPv2-CONF
switch FROM PRVT-SWITCH-MIB;
-------------------------------------------------------------------------------
-- PRIVATE BRANCH PRODUCTS
-------------------------------------------------------------------------------
prvtResilientLinkMib MODULE-IDENTITY
LAST-UPDATED "200502160000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The Resilient Link MIB module for managing switch or ipSwitch
resilient link"
-- revision history
REVISION "200502160000Z"
DESCRIPTION
"Fixed spelling errors and changed the contact info."
REVISION "200305060000Z"
DESCRIPTION
"Move to SMI-V2."
REVISION "200201280000Z"
DESCRIPTION
"Initial version."
::= { switch 102 }
-- -----------------------------------------------------------------------------
-- resilient link configuration parameters
-- -----------------------------------------------------------------------------
prvtResilientLinkNotifications OBJECT IDENTIFIER ::= { prvtResilientLinkMib 0 }
resilientLinkConfig OBJECT IDENTIFIER ::= { prvtResilientLinkMib 1 }
resilientLinkStatus OBJECT IDENTIFIER ::= { prvtResilientLinkMib 2 }
prvtResilientLinkConformance OBJECT IDENTIFIER ::= { prvtResilientLinkMib 3 }
resilientLinkConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ResilientLinkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the resilient link configuration."
::= { resilientLinkConfig 1 }
resilientLinkConfigEntry OBJECT-TYPE
SYNTAX ResilientLinkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"resilientLinkIndex"
INDEX { resilientLinkIndex }
::= { resilientLinkConfigTable 1 }
ResilientLinkConfigEntry ::= SEQUENCE {
resilientLinkIndex INTEGER,
resilientLinkEnable INTEGER,
resilientLinkPort1ifIndex INTEGER,
resilientLinkPort2ifIndex INTEGER,
resilientLinkPreferredPort INTEGER,
resilientLinkActivePort INTEGER
}
resilientLinkIndex OBJECT-TYPE
SYNTAX INTEGER(0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the resilient link"
::= { resilientLinkConfigEntry 1 }
resilientLinkEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables or disables the resilient link"
::= { resilientLinkConfigEntry 2 }
resilientLinkPort1ifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the first port belonging to this
resilient link; zero means no port is selected"
::= { resilientLinkConfigEntry 3 }
resilientLinkPort2ifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the second port belonging to this
resilient link; zero means no port is selected"
::= { resilientLinkConfigEntry 4 }
resilientLinkPreferredPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the preferred port (1 or 2) in this
resilient link; zero means no port is preferred"
::= { resilientLinkConfigEntry 5 }
resilientLinkActivePort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the active port (1 or 2) in this
resilient link. Only ports with link up can be configured as active
ports."
::= { resilientLinkConfigEntry 6 }
-- -----------------------------------------------------------------------------
-- resilient link status
-- -----------------------------------------------------------------------------
resilientLinkStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ResilientLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the resilient link status."
::= { resilientLinkStatus 2 }
resilientLinkStatusEntry OBJECT-TYPE
SYNTAX ResilientLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"resilientLinkIndex"
INDEX { resilientLinkIndex }
::= { resilientLinkStatusTable 1 }
ResilientLinkStatusEntry ::= SEQUENCE {
resilientLinkConnectedPort INTEGER,
resilientLinkCurrentActivePort INTEGER
}
resilientLinkConnectedPort OBJECT-TYPE
SYNTAX INTEGER {
notConnected(1),
port1Connected(2),
port2Connected(3),
port1and2Connected(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the connected ports in the resilient link"
::= { resilientLinkStatusEntry 1 }
resilientLinkCurrentActivePort OBJECT-TYPE
SYNTAX INTEGER {
noActivePort (1),
port1Active (2),
port2Active (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the active port (1 or 2) in this
resilient link. Only ports with link up can be configured as active
ports."
::= { resilientLinkStatusEntry 2 }
-- Traps for use by prvtResilientLinkMib
resilientLinkStatusChange NOTIFICATION-TYPE
OBJECTS { resilientLinkIndex, resilientLinkConnectedPort,
resilientLinkCurrentActivePort}
STATUS current
DESCRIPTION
"The resilientLinkStatusChange trap indicates that
the sending agent monitor detected a change in the status of the
resilient link, identified by resilientLinkIndex."
::= {prvtResilientLinkNotifications 1}
-- *******************************************************************
-- Conformance Information
-- *******************************************************************
prvtResilientLinkMIBGroups OBJECT IDENTIFIER ::= { prvtResilientLinkConformance 2 }
resilientLinkNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
resilientLinkStatusChange
}
STATUS current
DESCRIPTION
"Private Notification Group."
::= { prvtResilientLinkMIBGroups 3 }
END
|