summaryrefslogtreecommitdiff
path: root/MIBS/transition/TN-ENTITY-SENSOR-MIB
blob: dc2920e7d0711325ee56dbbf30a4b35e68b8e30e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
-- *****************************************************************
-- TN-ENTITY-SENSOR-MIB
--
-- Copyright (c) 2011, Transition Networks Inc.
-- All rights reserved.
-- *****************************************************************
--
TN-ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE, 
    NOTIFICATION-TYPE, 
    Integer32   FROM SNMPv2-SMI
    NOTIFICATION-GROUP  FROM SNMPv2-CONF
    TEXTUAL-CONVENTION, TimeStamp,
    TruthValue  FROM SNMPv2-TC
    entPhysicalIndex  FROM ENTITY-MIB
    entPhySensorValue, EntitySensorValue FROM ENTITY-SENSOR-MIB
    tnProducts FROM TRANSITION-SMI;

tnEntitySensorMIB MODULE-IDENTITY
        LAST-UPDATED "201101080000Z"
	ORGANIZATION "Transition Networks, Inc."
	CONTACT-INFO
		"	Transition Networks
			Technical Support

			10900 Red Circle Drive
			Minnetonka, MN 55343 USA
			Tel: +1-800-526-9267
			
		    E-mail: techsupport@transition.com"
	DESCRIPTION
		"The mib module for managing all powersupply and fan modules."                           
		
	REVISION      "200901080000Z"
		DESCRIPTION  
		"Initial Revision of this module"
	::= { tnProducts 6 }

tnEntitySensorMIBNotifications
        OBJECT IDENTIFIER ::= { tnEntitySensorMIB 0 }

tnEntitySensorMIBObjects
        OBJECT IDENTIFIER ::= { tnEntitySensorMIB 1 }

tnEntitySensorMIBConformance
        OBJECT IDENTIFIER ::= { tnEntitySensorMIB 2 }

-- Textual Conventions
TnSensorThresholdSeverity ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "sensor threshold severity.  Valid values are:

        other(1)    : a severity other than those listed below.
        minor(10)   : Minor Problem threshold.
        major(20)   : Major Problem threshold.
        critical(30): Critical problem threshold. A system might shut
                      down the sensor associated FRU automatically if
                      the sensor value reach the critical problem
                      threshold."
    SYNTAX INTEGER {
        other(1),
        minor(10),
        major(20),
        critical(30)
    }

TnSensorThresholdRelation ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "sensor threshold relational operator types.  valid values are:

        lessThan(1):        if the sensor value is less than
                            the threshold value
        lessOrEqual(2):     if the sensor value is less than or equal to
                            the threshold value
        greaterThan(3):     if the sensor value is greater than 
                            the threshold value
        greaterOrEqual(4):  if the sensor value is greater than or equal
                            to the threshold value
        equalTo(5):         if the sensor value is equal to
                            the threshold value
        notEqualTo(6):      if the sensor value is not equal to
                            the threshold value
        "
    SYNTAX INTEGER {
        lessThan(1),
        lessOrEqual(2),
        greaterThan(3),
        greaterOrEqual(4),
        equalTo(5),
        notEqualTo(6)
    }

--
-- MIB variables
-- 

tnEntSensorValues
    OBJECT IDENTIFIER ::= { tnEntitySensorMIBObjects 1 }

tnEntSensorThresholds
    OBJECT IDENTIFIER ::= { tnEntitySensorMIBObjects 2 }
    
tnEntSensorGlobalObjects
    OBJECT IDENTIFIER ::= { tnEntitySensorMIBObjects 3 }
           
--
-- tnEntValueExtTable
--           
tnEntSensorExtTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF TnEntSensorExtEntry 
    MAX-ACCESS    not-accessible
    STATUS        current 
    DESCRIPTION                                   
        "This table is an private extension of the public 
        ENTITY-SENSOR-MIB  entPhySensorTable."
    ::= { tnEntSensorValues 1 }
 
tnEntSensorExtEntry OBJECT-TYPE
    SYNTAX        TnEntSensorExtEntry 
    MAX-ACCESS    not-accessible
    STATUS        current 
    DESCRIPTION                       
        "The entries list the unique properties of the
        ION Power supply module."   
    INDEX { entPhysicalIndex }
    ::= { tnEntSensorExtTable 1 }
                               
TnEntSensorExtEntry ::= SEQUENCE {
    tnEntSensorExtRelayInstalled   TruthValue,
    tnEntSensorExtRelayEnabled     TruthValue,
    tnEntSensorExtModuleType       INTEGER,
    tnEntSensorExtOperMode         INTEGER
    }

tnEntSensorExtRelayInstalled OBJECT-TYPE
    SYNTAX        TruthValue 
    MAX-ACCESS    read-only
    STATUS        current 
    DESCRIPTION
        "This variable indicates if the relay contact is installed
        on the power supply module or not."
    ::= { tnEntSensorExtEntry 1 }

tnEntSensorExtRelayEnabled OBJECT-TYPE
    SYNTAX        TruthValue 
    MAX-ACCESS    read-write
    STATUS        current 
    DESCRIPTION
        "This variable enables or disables the relay contact if
        it is installed (tnEntSensorExtRelayInstalled) in the power supply.
        This relay contact is used to trigger an event to the user by attaching
        an external indicator."
    ::= { tnEntSensorExtEntry 2 }
 
tnEntSensorExtModuleType OBJECT-TYPE
    SYNTAX        INTEGER { acModule(1), dcModule(2) } 
    MAX-ACCESS    read-only
    STATUS        current 
    DESCRIPTION
        "This variable indicates if the power supply is
        AC or DC module."
    ::= { tnEntSensorExtEntry 3 }
      
tnEntSensorExtOperMode OBJECT-TYPE
    SYNTAX        INTEGER { master(1), slave(2) } 
    MAX-ACCESS    read-only
    STATUS        current 
    DESCRIPTION
        "This variable indicates operational mode of the
        power supply when redundant modules exists."
    ::= { tnEntSensorExtEntry 4 }
      
--
-- tnEntSensorThresholdTable 
-- 

tnEntSensorThresholdTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF TnEntSensorThresholdEntry 
    MAX-ACCESS    not-accessible
    STATUS        current 
    DESCRIPTION
        "This table lists the threshold severity, relation, and
        comparison value, for a sensor listed in the Entity-MIB 
        EntPhysicalTable."
    ::= { tnEntSensorThresholds 1 }

tnEntSensorThresholdEntry OBJECT-TYPE
    SYNTAX        TnEntSensorThresholdEntry 
    MAX-ACCESS    not-accessible
    STATUS        current 
    DESCRIPTION   
         "An tnEntSensorThresholdTable Entry describes the 
         thresholds for a sensor: the threshold severity,
         the threshold value, the relation, and the 
         evaluation of the threshold.

         Only Entities of type sensor(8) are listed in this table.
         Only pre-configured thresholds are listed in this table.

         Users can create sensor-value monitoring instrumionEnts
         in differionEnt ways, such as RMON alarms, Expression-MIB, etc.

         Entries are created by the agionEnt at system startup and
         FRU insertion.  Entries are deleted by the agionEnt at
         FRU removal."
    INDEX         { entPhysicalIndex, tnEntSensorThresholdIndex }
    ::= { tnEntSensorThresholdTable 1 }

TnEntSensorThresholdEntry ::= SEQUENCE {
    tnEntSensorThresholdIndex               Integer32,
    tnEntSensorThresholdSeverity            TnSensorThresholdSeverity,
    tnEntSensorThresholdRelation            TnSensorThresholdRelation,
    tnEntSensorThresholdValue               EntitySensorValue,
    tnEntSensorThresholdEvaluation          TruthValue,
    tnEntSensorThresholdNotificationEnable  TruthValue
    }

tnEntSensorThresholdIndex OBJECT-TYPE
    SYNTAX        Integer32 (1..99999999)
    MAX-ACCESS    not-accessible
    STATUS        current 
    DESCRIPTION
        "An index that uniquely identifies an entry
        in the tnEntSensorThresholdTable. This index
        permits the same sensor to have several 
        different thresholds."
    ::= { tnEntSensorThresholdEntry 1 }

tnEntSensorThresholdSeverity OBJECT-TYPE
    SYNTAX        TnSensorThresholdSeverity 
    MAX-ACCESS    read-write
    STATUS        current 
    DESCRIPTION
        "This variable indicates the severity of this threshold."
    ::= { tnEntSensorThresholdEntry 2 }

tnEntSensorThresholdRelation OBJECT-TYPE
    SYNTAX        TnSensorThresholdRelation 
    MAX-ACCESS    read-write
    STATUS        current 
    DESCRIPTION
        "This variable indicates the relation between sensor value 
        (entSensorValue) and threshold value (tnEntSensorThresholdValue), 
        required to trigger the alarm.  when evaluating the relation, 
        entSensorValue is on the left of tnEntSensorThresholdRelation, 
        tnEntSensorThresholdValue is on the right. 

        in pseudo-code, the evaluation-alarm mechanism is:
 
        ...
        if (entSensorStatus == ok) then
            if (evaluate(entSensorValue, tnEntSensorThresholdRelation,  
                tnEntSensorThresholdValue)) 
            then
                if (tnEntSensorThresholdNotificationEnable == true)) 
                then
                    raise_alarm(sensor's entPhysicalIndex);
                endif
            endif
        endif
        ...
        "
    ::= { tnEntSensorThresholdEntry 3 }

tnEntSensorThresholdValue OBJECT-TYPE
    SYNTAX        EntitySensorValue 
    MAX-ACCESS    read-write
    STATUS        current 
    DESCRIPTION
        "This variable indicates the value of the threshold.

        To correctly display or interpret this variable's value, 
        you must also know entSensorType, entSensorScale, and 
        entSensorPrecision.

        However, you can directly compare entSensorValue 
        with the threshold values given in tnEntSensorThresholdTable 
        without any semantic knowledge.
        "
    ::= { tnEntSensorThresholdEntry 4 }

tnEntSensorThresholdEvaluation  OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "This variable indicates the result of the most
        recent evaluation of the threshold.  If the threshold
        condition is true, tnEntSensorThresholdEvaluation 
        is true(1).  If the threshold condition is false, 
        tnEntSensorThresholdEvaluation is false(2).

        Thresholds are evaluated at the rate indicated by 
        entSensorValueUpdateRate.        
        "
    ::= { tnEntSensorThresholdEntry 5 }

tnEntSensorThresholdNotificationEnable OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
        "This variable controls generation of 
        tnEntSensorThresholdNotification for this threshold.

        When this variable is 'true', generation of 
        tnEntSensorThresholdNotification is enabled for this
        threshold. When this variable is 'false', 
        generation of tnEntSensorThresholdNotification is
        disabled for this threshold.
        "      
    ::= { tnEntSensorThresholdEntry 6 }

--
-- Entity Sensor Global Objects
--

 tnEntSensorThreshNotifGlobalEnable  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-write
     STATUS        current
     DESCRIPTION
         "This variable enables the generation of
          tnEntSensorThresholdNotification globally
          on the device. If this object value is
          'false', then no tnEntSensorThresholdNotification
          will be generated on this device. If this object
          value is 'true', then whether a 
          tnEntSensorThresholdNotification for a threshold will
          be generated or not depends on the instance value of
          tnEntSensorThresholdNotificationEnable for that
          threshold.
         "         
     ::= { tnEntSensorGlobalObjects 1}
     
--
-- notifications
--
tnEntSensorThresholdNotification NOTIFICATION-TYPE
    OBJECTS { entPhySensorValue, tnEntSensorThresholdValue, tnEntSensorThresholdSeverity }
    STATUS current
    DESCRIPTION
        "The sensor value crossed the threshold 
        listed in tnEntSensorThresholdTable.

        This notification is generated once each time
        the sensor value crosses the threshold.
        
        The agent implementation guarantees prompt, timely
        evaluation of threshold and generation of this
        notification.
        "
    ::= { tnEntitySensorMIBNotifications 1 }
         
END