1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
|
-- *****************************************************************
-- TN-HQOS-MIB: TN HQOS private MIB
--
-- Copyright (c) 2015 by Transition Networks, Inc.
-- All Rights Reserved.
--
-- ****************************************************************
TN-HQOS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
tnProducts
FROM TRANSITION-SMI
Integer32 FROM SNMPv2-SMI
Unsigned32 FROM SNMPv2-SMI
TruthValue FROM SNMPv2-TC
TNInterfaceIndex FROM TN-TC
TNRowEditorState FROM TN-TC
TNUnsigned8 FROM TN-TC
;
tnHqosMib MODULE-IDENTITY
LAST-UPDATED "201504200000Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
"Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com"
DESCRIPTION
"The mib module for HQOS settings."
REVISION "201504200000Z"
DESCRIPTION
"Initial Revision of this module"
::= { tnProducts 145 }
TNhqosSchMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The HQoS scheduling mode."
SYNTAX INTEGER { normal(0), basic(1), hierarchical(2) }
tnHqosMibObjects OBJECT IDENTIFIER
::= { tnHqosMib 1 }
tnHqosConfig OBJECT IDENTIFIER
::= { tnHqosMibObjects 2 }
tnHqosConfigInterface OBJECT IDENTIFIER
::= { tnHqosConfig 2 }
tnHqosConfigInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF TNHqosConfigInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides HQoS configuration for interfaces"
::= { tnHqosConfigInterface 1 }
tnHqosConfigInterfaceEntry OBJECT-TYPE
SYNTAX TNHqosConfigInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row contains the configuration for an interface"
INDEX { tnHqosConfigInterfaceIfIndex }
::= { tnHqosConfigInterfaceTable 1 }
TNHqosConfigInterfaceEntry ::= SEQUENCE {
tnHqosConfigInterfaceIfIndex TNInterfaceIndex,
tnHqosConfigInterfaceSchMode TNhqosSchMode
}
tnHqosConfigInterfaceIfIndex OBJECT-TYPE
SYNTAX TNInterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Logical interface index."
::= { tnHqosConfigInterfaceEntry 1 }
tnHqosConfigInterfaceSchMode OBJECT-TYPE
SYNTAX TNhqosSchMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"HQoS scheduling mode."
::= { tnHqosConfigInterfaceEntry 2 }
tnHqosConfigInterfaceHqosTable OBJECT-TYPE
SYNTAX SEQUENCE OF TNHqosConfigInterfaceHqosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the configuration for HQoS entries"
::= { tnHqosConfigInterface 2 }
tnHqosConfigInterfaceHqosEntry OBJECT-TYPE
SYNTAX TNHqosConfigInterfaceHqosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row contains the configuration for an HQoS entry"
INDEX { tnHqosConfigInterfaceHqosIfIndex, tnHqosConfigInterfaceHqosHqosId }
::= { tnHqosConfigInterfaceHqosTable 1 }
TNHqosConfigInterfaceHqosEntry ::= SEQUENCE {
tnHqosConfigInterfaceHqosIfIndex TNInterfaceIndex,
tnHqosConfigInterfaceHqosHqosId Integer32,
tnHqosConfigInterfaceHqosDwrrCount TNUnsigned8,
tnHqosConfigInterfaceHqosShaperEnable TruthValue,
tnHqosConfigInterfaceHqosShaperRate Unsigned32,
tnHqosConfigInterfaceHqosMinRate Unsigned32,
tnHqosConfigInterfaceHqosAction TNRowEditorState
}
tnHqosConfigInterfaceHqosIfIndex OBJECT-TYPE
SYNTAX TNInterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Logical interface index."
::= { tnHqosConfigInterfaceHqosEntry 1 }
tnHqosConfigInterfaceHqosHqosId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"HQoS ID, allowed range depends on platform."
::= { tnHqosConfigInterfaceHqosEntry 2 }
tnHqosConfigInterfaceHqosDwrrCount OBJECT-TYPE
SYNTAX TNUnsigned8
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of queues using DWRR."
::= { tnHqosConfigInterfaceHqosEntry 3 }
tnHqosConfigInterfaceHqosShaperEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable shaper."
::= { tnHqosConfigInterfaceHqosEntry 4 }
tnHqosConfigInterfaceHqosShaperRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shaper rate in kbps."
::= { tnHqosConfigInterfaceHqosEntry 5 }
tnHqosConfigInterfaceHqosMinRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum guaranteed bandwidth in kbps."
::= { tnHqosConfigInterfaceHqosEntry 6 }
tnHqosConfigInterfaceHqosAction OBJECT-TYPE
SYNTAX TNRowEditorState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action"
::= { tnHqosConfigInterfaceHqosEntry 10000 }
tnHqosConfigInterfaceHqosTableRowEditor OBJECT IDENTIFIER
::= { tnHqosConfigInterface 3 }
tnHqosConfigInterfaceHqosTableRowEditorIfIndex OBJECT-TYPE
SYNTAX TNInterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Logical interface index."
::= { tnHqosConfigInterfaceHqosTableRowEditor 1 }
tnHqosConfigInterfaceHqosTableRowEditorHqosId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"HQoS ID, allowed range depends on platform."
::= { tnHqosConfigInterfaceHqosTableRowEditor 2 }
tnHqosConfigInterfaceHqosTableRowEditorDwrrCount OBJECT-TYPE
SYNTAX TNUnsigned8
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of queues using DWRR."
::= { tnHqosConfigInterfaceHqosTableRowEditor 3 }
tnHqosConfigInterfaceHqosTableRowEditorShaperEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable shaper."
::= { tnHqosConfigInterfaceHqosTableRowEditor 4 }
tnHqosConfigInterfaceHqosTableRowEditorShaperRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shaper rate in kbps."
::= { tnHqosConfigInterfaceHqosTableRowEditor 5 }
tnHqosConfigInterfaceHqosTableRowEditorMinRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum guaranteed bandwidth in kbps."
::= { tnHqosConfigInterfaceHqosTableRowEditor 6 }
tnHqosConfigInterfaceHqosTableRowEditorAction OBJECT-TYPE
SYNTAX TNRowEditorState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action"
::= { tnHqosConfigInterfaceHqosTableRowEditor 10000 }
tnHqosConfigInterfaceHqosQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF TNHqosConfigInterfaceHqosQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the configuration for HQoS queues"
::= { tnHqosConfigInterface 4 }
tnHqosConfigInterfaceHqosQueueEntry OBJECT-TYPE
SYNTAX TNHqosConfigInterfaceHqosQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row contains the configuration for a queue of an HQoS entry"
INDEX { tnHqosConfigInterfaceHqosQueueIfIndex, tnHqosConfigInterfaceHqosQueueHqosId, tnHqosConfigInterfaceHqosQueueQueue }
::= { tnHqosConfigInterfaceHqosQueueTable 1 }
TNHqosConfigInterfaceHqosQueueEntry ::= SEQUENCE {
tnHqosConfigInterfaceHqosQueueIfIndex TNInterfaceIndex,
tnHqosConfigInterfaceHqosQueueHqosId Integer32,
tnHqosConfigInterfaceHqosQueueQueue Integer32,
tnHqosConfigInterfaceHqosQueueShaperEnable TruthValue,
tnHqosConfigInterfaceHqosQueueShaperRate Unsigned32,
tnHqosConfigInterfaceHqosQueueSchedulerWeight TNUnsigned8
}
tnHqosConfigInterfaceHqosQueueIfIndex OBJECT-TYPE
SYNTAX TNInterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Logical interface index."
::= { tnHqosConfigInterfaceHqosQueueEntry 1 }
tnHqosConfigInterfaceHqosQueueHqosId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"HQoS ID, allowed range depends on platform."
::= { tnHqosConfigInterfaceHqosQueueEntry 2 }
tnHqosConfigInterfaceHqosQueueQueue OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Queue number."
::= { tnHqosConfigInterfaceHqosQueueEntry 3 }
tnHqosConfigInterfaceHqosQueueShaperEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable shaper."
::= { tnHqosConfigInterfaceHqosQueueEntry 4 }
tnHqosConfigInterfaceHqosQueueShaperRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shaper rate in kbps."
::= { tnHqosConfigInterfaceHqosQueueEntry 5 }
tnHqosConfigInterfaceHqosQueueSchedulerWeight OBJECT-TYPE
SYNTAX TNUnsigned8
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Scheduler weight, 1-100."
::= { tnHqosConfigInterfaceHqosQueueEntry 6 }
tnHqosConfigHqos OBJECT IDENTIFIER
::= { tnHqosConfig 4 }
tnHqosMibConformance OBJECT IDENTIFIER
::= { tnHqosMib 2 }
tnHqosMibCompliances OBJECT IDENTIFIER
::= { tnHqosMibConformance 1 }
tnHqosMibGroups OBJECT IDENTIFIER
::= { tnHqosMibConformance 2 }
tnHqosConfigInterfaceTableInfoGroup OBJECT-GROUP
OBJECTS { tnHqosConfigInterfaceSchMode }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { tnHqosMibGroups 1 }
tnHqosConfigInterfaceHqosTableInfoGroup OBJECT-GROUP
OBJECTS { tnHqosConfigInterfaceHqosDwrrCount,
tnHqosConfigInterfaceHqosShaperEnable,
tnHqosConfigInterfaceHqosShaperRate,
tnHqosConfigInterfaceHqosMinRate,
tnHqosConfigInterfaceHqosAction }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { tnHqosMibGroups 2 }
tnHqosConfigInterfaceHqosTableRowEditorInfoGroup OBJECT-GROUP
OBJECTS { tnHqosConfigInterfaceHqosTableRowEditorIfIndex,
tnHqosConfigInterfaceHqosTableRowEditorHqosId,
tnHqosConfigInterfaceHqosTableRowEditorDwrrCount,
tnHqosConfigInterfaceHqosTableRowEditorShaperEnable,
tnHqosConfigInterfaceHqosTableRowEditorShaperRate,
tnHqosConfigInterfaceHqosTableRowEditorMinRate,
tnHqosConfigInterfaceHqosTableRowEditorAction }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { tnHqosMibGroups 3 }
tnHqosConfigInterfaceHqosQueueTableInfoGroup OBJECT-GROUP
OBJECTS { tnHqosConfigInterfaceHqosQueueShaperEnable,
tnHqosConfigInterfaceHqosQueueShaperRate,
tnHqosConfigInterfaceHqosQueueSchedulerWeight }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { tnHqosMibGroups 4 }
tnHqosMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the implementation."
MODULE -- this module
MANDATORY-GROUPS { tnHqosConfigInterfaceTableInfoGroup,
tnHqosConfigInterfaceHqosTableInfoGroup,
tnHqosConfigInterfaceHqosTableRowEditorInfoGroup,
tnHqosConfigInterfaceHqosQueueTableInfoGroup }
::= { tnHqosMibCompliances 1 }
END
|