summaryrefslogtreecommitdiff
path: root/MIBS/transition/TN-SYNCE-MIB
blob: 42fa67057488513859c5740b1455d82c839751c6 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
-- ***********************************************************************************************
-- TN-SYNCE-MIB.smi:  Transition Networks Enterprise MIB for TN device SyncE feature
--
-- Copyright (c) 2013 by Transition Networks, Inc.
-- All rights reserved.
--
-- ***********************************************************************************************
--

TN-SYNCE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    TruthValue FROM SNMPv2-TC
    MODULE-IDENTITY,
    OBJECT-IDENTITY,
    entPhysicalIndex FROM ENTITY-MIB
    tnProducts FROM TRANSITION-SMI;

tnSynceMIB MODULE-IDENTITY
    LAST-UPDATED "201305160000Z"
    ORGANIZATION "Transition Networks, Inc."
    CONTACT-INFO
                "       Transition Networks
                        Technical Support

                        10900 Red Circle Drive
                        Minnetonka, MN 55343 USA
                        Tel: +1-800-526-9267

                    E-mail: techsupport@transition.com"
    DESCRIPTION
        "The mib provides functionalities for managing SyncE."

    REVISION      "201305160000Z"
    DESCRIPTION
        "Initial Revision of this module"
        ::= { tnProducts 122 }

tnSynce            OBJECT IDENTIFIER ::= { tnSynceMIB 1 }

tnSyncETable OBJECT-TYPE
    SYNTAX     SEQUENCE OF TnSyncEEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "Table to manage SyncE for each device."
    ::= { tnSynce 1 }

tnSyncEEntry OBJECT-TYPE
    SYNTAX TnSyncEEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "An entry containing SyncE for each device."
    INDEX   { entPhysicalIndex }
    ::= { tnSyncETable 1 }

TnSyncEEntry ::=
    SEQUENCE {
        tnSyncEStateMode        INTEGER,
        tnSyncEStateWTRTime     INTEGER,
        tnSyncEStateSSMHoldOver INTEGER,
        tnSyncEStateSSMFreeRun  INTEGER,
        tnSyncEAlarmStateLOL    TruthValue,
        tnSyncEAlarmStateDHOLD  TruthValue,
        tnSyncESelState         INTEGER,
        tnSyncEClkSrc           INTEGER
    }

tnSyncEStateMode OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    manual(1),
                    selected(2),
                    nonrevertive(3),
                    revertive(4),
                    holdover(5),
                    freerun(6)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Clock source selection mode
     manual:       Selector is manually set to the chosen clock source
     selected:     Selector is manually set to the pt. selected clock source (not possible in unlocked mode)
     nonrevertive: Selector is automatically selecting the best clock source - non revertively
     revertive:    Selector is automatically selecting the best clock source - revertively
     holdover:     Selector is forced in holdover
     freerun:      Selector is forced in free run"
    ::= { tnSyncEEntry 1 }

tnSyncEStateWTRTime OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "WTR (Wait-to-Restore) time in minutes(0-12 min) '0' is disable"
    ::= { tnSyncEEntry 2 }

tnSyncEStateSSMHoldOver  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    none(0),
                    prc(1),
                    ssua(2),
                    ssub(3),
                    eec2(4),
                    eec1(5),
                    dnu(6),
                    inv(7)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Synchronization Status Messaging Hold Over.
    Hold Over is switching over to Local Reference Clock if primary and secondary nodes fail
    prc = Primary Reference Clock
    eec2 Ethernet Equipment Clock 1.544 kpbs
    eec1 Ethernet Equipment Clock 2.048 kpbs"
    ::= { tnSyncEEntry 3 }

tnSyncEStateSSMFreeRun OBJECT-TYPE
    SYNTAX      INTEGER
                {
                     none(0),
                     prc(1),
                     ssua(2),
                     ssub(3),
                     eec2(4),
                     eec1(5),
                     dnu(6),
                     inv(7)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Synchronization Status Messaging Free Run"
    ::= { tnSyncEEntry 4 }

tnSyncEAlarmStateLOL OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Alarm State Loss of Lock (LOL)"
    ::= { tnSyncEEntry 5 }

tnSyncEAlarmStateDHOLD OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Alarm State Digital Hold (DHOLD)"
    ::= { tnSyncEEntry 6 }

tnSyncESelState OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    lockedto(1),
                    holdover(2),
                    freerun(3),
                    prelock2(4),
                    prelock(5),
                    lossoflock(6)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Clock Selection State
                 Note: prelock2, prelock and lossoflock
                 are not available on all products"
    ::= { tnSyncEEntry 7 }

tnSyncEClkSrc OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Clock Source"
    ::= { tnSyncEEntry 8 }

--
-- SyncEClkSource
--
tnSyncEClkSourceTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF TnSyncEClkSourceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Table of SyncE ClkSource"
    ::= { tnSynce 2 }

tnSyncEClkSourceEntry  OBJECT-TYPE
    SYNTAX      TnSyncEClkSourceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "An entry in the table,tnSyncEClkSourceTable"
    INDEX       { entPhysicalIndex, tnSyncEClkSourceIndex }
    ::= { tnSyncEClkSourceTable 1 }

TnSyncEClkSourceEntry ::= SEQUENCE
{
    tnSyncEClkSourceIndex    INTEGER,
    tnSyncEConfPort          INTEGER,
    tnSyncEConfSSMOverwrite  INTEGER,
    tnSyncEConfHoldOff       INTEGER,
    tnSyncEConfANEG          INTEGER,
    tnSyncEPriority          INTEGER,
    tnSyncEClear             TruthValue,
    tnSyncEAlarmStateLOCS    TruthValue,
    tnSyncEAlarmStateSSM     TruthValue,
    tnSyncEAlarmStateWTR     TruthValue,
    tnSyncENominated         TruthValue
}

tnSyncEClkSourceIndex  OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Index of SyncE ClkSource table. 1-SYNCE_NOMINATED_MAX"
    ::= { tnSyncEClkSourceEntry 1 }

tnSyncEConfPort  OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "SyncE Configuration Port. 0-MAX_PORT.
                 a port value of 0 means not nominated"
    ::= { tnSyncEClkSourceEntry 2 }

tnSyncEConfSSMOverwrite OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    none(0),
                    prc(1),
                    ssua(2),
                    ssub(3),
                    eec2(4),
                    eec1(5),
                    dnu(6)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Clock source SSM overwrite"
    ::= { tnSyncEClkSourceEntry 3 }

tnSyncEConfHoldOff  OBJECT-TYPE
    SYNTAX     INTEGER
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION "The hold off timer value in 100 ms.
           Valid values are: 0 for disable. The range 3-18. The value 100 for test"
    ::= { tnSyncEClkSourceEntry 4 }

tnSyncEConfANEG OBJECT-TYPE
    SYNTAX      INTEGER
                {
                     none(0),
                     slave(1),
                     master(2),
                     forced(3)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Auto Negotiate : 1000BaseT ANEG mode
        slave:  Activate prefer slave negotiation
        master: Activate prefer master negotiation
        forced: Activate forced slave negotiation."
    ::= { tnSyncEClkSourceEntry 5 }

tnSyncEPriority OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Clock source priority setting. (SYNCE_PRIORITY_MAX = CLOCK_INPUT_MAX = 2 i.e. 0,1)"
    ::= { tnSyncEClkSourceEntry 6 }

tnSyncEClear OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "SyncE Clear."
    ::= { tnSyncEClkSourceEntry 7 }

tnSyncEAlarmStateLOCS OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "SyncE Alarm State LOCS."
    ::= { tnSyncEClkSourceEntry 8 }

tnSyncEAlarmStateSSM OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION " SyncE Alarm State SSM."
    ::= { tnSyncEClkSourceEntry 9 }

tnSyncEAlarmStateWTR OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "SyncE Alarm State WRT."
    ::= { tnSyncEClkSourceEntry 10 }

tnSyncENominated OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "SyncE Nominated."
    ::= { tnSyncEClkSourceEntry 11 }

--
-- SyncE port table
--
tnSyncEPortTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF TnSyncEPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Table of SyncEPort."
    ::= { tnSynce 3 }


tnSyncEPortEntry OBJECT-TYPE
    SYNTAX TnSyncEPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "An entry containing tnSynce."
    INDEX   { entPhysicalIndex, tnSyncEStatePortIndex }
    ::= { tnSyncEPortTable 1 }

TnSyncEPortEntry ::=
    SEQUENCE {
                tnSyncEStatePortIndex INTEGER,
                tnSyncEStateTxSSM INTEGER,
                tnSyncEStateRxSSM INTEGER,
                tnSyncEStateSSMMode INTEGER,
                tnSyncESSMEnabled  INTEGER
             }

tnSyncEStatePortIndex OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "SyncE Port index, 0-SYNCE_PORT_COUNT."
    ::= { tnSyncEPortEntry 1 }

tnSyncEStateTxSSM OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    none(0),
                    prc(1),
                    ssua(2),
                    ssub(3),
                    dnu(4),
                    eec2(5),
                    eec1(6),
                    inv(7),
                    fail(8),
                    link(9)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "SyncE Transmit SSM State."
    ::= { tnSyncEPortEntry 2 }

tnSyncEStateRxSSM OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    none(0),
                    prc(1),
                    ssua(2),
                    ssub(3),
                    dnu(4),
                    eec2(5),
                    eec1(6),
                    inv(7),
                    fail(8),
                    link(9)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "SyncE Receive SSM State."
    ::= { tnSyncEPortEntry 3 }

tnSyncEStateSSMMode OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    master(1),
                    slave(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "SyncE SSM Mode."
    ::= { tnSyncEPortEntry 4 }

tnSyncESSMEnabled OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    enable(1),
                    disable(2)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "SyncE SSM Enabled."
    ::= { tnSyncEPortEntry 5 }

--
-- SyncE External I/O
--
tnSyncEExtTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF TnSyncEExtEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Table of SyncE External I/O"
    ::= { tnSynce 4 }

tnSyncEExtEntry  OBJECT-TYPE
    SYNTAX      TnSyncEExtEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "An entry in the table,tnSyncEExtTable"
    INDEX       { entPhysicalIndex }
    ::= { tnSyncEExtTable 1 }

TnSyncEExtEntry ::= SEQUENCE
{
    tnSyncEExtInState        INTEGER,
    tnSyncEExtOutState       INTEGER,
    tnSyncEExtInFreq         INTEGER,
    tnSyncEExtOutFreq        INTEGER,
    tnSyncEExtImpedance      INTEGER,
    tnSyncEActualInFreq      INTEGER,
    tnSyncEActualOutFreq     INTEGER
}

tnSyncEExtInState  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    enable(1),
                    disable(2)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "External I/O in direction state."
    ::= { tnSyncEExtEntry 1 }

tnSyncEExtOutState  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    enable(1),
                    disable(2)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "External I/O out direction state."
    ::= { tnSyncEExtEntry 2 }

tnSyncEExtInFreq  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    f8kHz(1),
                    f64kHz(2),
                    f1544kHz(3),
                    f2048kHz(4),
                    f10000kHz(5),
                    f19440kHz(6),
                    f25Mhz(7)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "External I/O in direction frequency
                 8k-25Mhz table of values."
    ::= { tnSyncEExtEntry 3 }

tnSyncEExtOutFreq  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    f8kHz(1),
                    f64kHz(2),
                    f1544kHz(3),
                    f2048kHz(4),
                    f10000kHz(5),
                    f19440kHz(6),
                    f25Mhz(7)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "External I/O out direction frequency
                 8k-25Mhz table of values"
    ::= { tnSyncEExtEntry 4 }

tnSyncEExtImpedance  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                    imp50(1),
                    imp75(2),
                    hi-Z(3)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "External I/O Impedance."
    ::= { tnSyncEExtEntry 5 }

tnSyncEActualInFreq  OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The actual input frequency in Hz."
    ::= { tnSyncEExtEntry 6 }

tnSyncEActualOutFreq  OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The actual output frequency in Hz. If output state is disabled set to 0"
    ::= { tnSyncEExtEntry 7 }
END