summaryrefslogtreecommitdiff
path: root/MIBS/transition/TN-TT-LOOP-MIB
blob: 81edc1cd4b00823733cf2635eb192fb91e719b04 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
-- *****************************************************************
-- TT-LOOP-MIB : TN LOOPBACK private MIB
--
-- Copyright (c) 2015 by Transition Networks, Inc.
-- All rights reserved.
--
-- *****************************************************************

TN-TT-LOOP-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF
    MODULE-IDENTITY, OBJECT-TYPE
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION
        FROM SNMPv2-TC
    tnProducts
        FROM TRANSITION-SMI
    Integer32 FROM SNMPv2-SMI
    Unsigned32 FROM SNMPv2-SMI   
    DisplayString FROM SNMPv2-TC
    InterfaceIndex FROM IF-MIB
    ;

tnTtLoopMib MODULE-IDENTITY
    LAST-UPDATED "201507160000Z"
    ORGANIZATION "Transition Networks, Inc."
    CONTACT-INFO
        "Transition Networks
        Technical Support

        10900 Red Circle Drive
        Minnetonka, MN 55343 USA
        Tel: +1-800-526-9267

            E-mail: techsupport@transition.com"
    DESCRIPTION
        "This is a private Traffic Test Loop MIB that can be used for RFC2544
         and Y.1564 (remote end) testing"
    REVISION    "201507160000Z"
    DESCRIPTION
        "Initial version"
    ::= { tnProducts 149 }


TNTtLoopInstanceAdminState ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The instance Administrative State."
    SYNTAX      INTEGER { adminDisabled(0), adminEnabled(1) }

TNTtLoopInstanceDomain ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Domain."
    SYNTAX      INTEGER { port(0), evc(1), vlan(2) }

TNTtLoopInstanceDirection ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The instance direction."
    SYNTAX      INTEGER { facility(0), terminal(1) }

TNTtLoopInstanceSubscriber ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The instance subscriber mode."
    SYNTAX      INTEGER { none(0), all(1), test(2) }

TNTtLoopInstanceType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The instance type."
    SYNTAX      INTEGER { macLoop(0), oamLoop(1) }
             
TNTtLoopInstanceOperState ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The instance Operational State."
    SYNTAX      INTEGER { operDown(0), operUp(1) }
    
tnTtLoopCapabilitiesInstanceMax OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Max number of TT_LOOP instance"
    ::= { tnTtLoopMib 1 }

tnTtLoopCapabilitiesNameMax OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Max length of instance name"
    ::= { tnTtLoopMib 2 }
 
tnTtLoopConfigInstanceTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF TNTtLoopConfigInstanceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "This is a table of created instance configuration parameters"
    ::= { tnTtLoopMib 3 }

tnTtLoopConfigInstanceEntry OBJECT-TYPE
    SYNTAX      TNTtLoopConfigInstanceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "This is a created instance configuration parameters. Not all parameters
         can be changed"
    INDEX       { tnTtLoopConfigInstanceId }
    ::= { tnTtLoopConfigInstanceTable 1 }

TNTtLoopConfigInstanceEntry ::= SEQUENCE {
    tnTtLoopConfigInstanceId      		Integer32,
    tnTtLoopConfigInstanceName    		DisplayString, 
    tnTtLoopConfigInstanceDomain        TNTtLoopInstanceDomain,
    tnTtLoopConfigInstanceType    		TNTtLoopInstanceType,
    tnTtLoopConfigInstanceDirection 	TNTtLoopInstanceDirection,
    tnTtLoopConfigInstanceFlow    		InterfaceIndex,
    tnTtLoopConfigInstancePort    		InterfaceIndex,
    tnTtLoopConfigInstanceLevel   		Unsigned32,
    tnTtLoopConfigInstanceSubscriber    TNTtLoopInstanceSubscriber,  
    tnTtLoopStatusInstanceOperState     TNTtLoopInstanceOperState,
    tnTtLoopConfigInstanceAdminState    TNTtLoopInstanceAdminState, 
    tnTtLoopConfigInstanceAction     	INTEGER
}

tnTtLoopConfigInstanceName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "Instance name"
    DEFVAL { "TRAFFIC_TEST_LOOP_INSTANCE" }
    ::= { tnTtLoopConfigInstanceEntry 1 }

tnTtLoopConfigInstanceDomain OBJECT-TYPE
    SYNTAX      TNTtLoopInstanceDomain
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "Domain"
    ::= { tnTtLoopConfigInstanceEntry 2 }

tnTtLoopConfigInstanceType OBJECT-TYPE
    SYNTAX      TNTtLoopInstanceType
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "The Traffic Test loop type. Currently OAM Loop is only supported in EVC
         domain."
    ::= { tnTtLoopConfigInstanceEntry 3 }

tnTtLoopConfigInstanceDirection OBJECT-TYPE
    SYNTAX      TNTtLoopInstanceDirection
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "The instance direction. Currently Terminal Loop is only supported in
         EVC domain."
    ::= { tnTtLoopConfigInstanceEntry 4 }

tnTtLoopConfigInstanceFlow OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "The flow instance. Currently VLAN domain is not supported."
    DEFVAL         { 1 }
    ::= { tnTtLoopConfigInstanceEntry 5 }

tnTtLoopConfigInstancePort OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "The instance residence port."
    DEFVAL         { 1 }
    ::= { tnTtLoopConfigInstanceEntry 6 }

tnTtLoopConfigInstanceLevel OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "The instance MEG level"
    ::= { tnTtLoopConfigInstanceEntry 7 }

tnTtLoopConfigInstanceSubscriber OBJECT-TYPE
    SYNTAX      TNTtLoopInstanceSubscriber
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "The EVC OAM loop subscriber mode"
    ::= { tnTtLoopConfigInstanceEntry 8 }

tnTtLoopStatusInstanceOperState OBJECT-TYPE
    SYNTAX      TNTtLoopInstanceOperState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The instance Operational state."
    ::= { tnTtLoopConfigInstanceEntry 9 }

tnTtLoopConfigInstanceAdminState OBJECT-TYPE
    SYNTAX      TNTtLoopInstanceAdminState
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "The instance Administrative state."
    ::= { tnTtLoopConfigInstanceEntry 10 }

tnTtLoopConfigInstanceAction OBJECT-TYPE
    SYNTAX       INTEGER{ noAction(0), save(1), delete(2) }

    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION 
        "Action"  
    DEFVAL         { 1 }
    ::= { tnTtLoopConfigInstanceEntry 11 }

END