summaryrefslogtreecommitdiff
path: root/MIBS/trellix/TRELLIX-SENSOR-CONF-MIB
blob: 24545410af2eb61ae4a9579344e58c5a34de3aa0 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
5535
5536
5537
5538
5539
5540
5541
5542
5543
5544
5545
5546
5547
5548
5549
5550
5551
5552
5553
5554
5555
5556
5557
5558
5559
5560
5561
5562
5563
5564
5565
5566
5567
5568
5569
5570
5571
5572
5573
5574
5575
5576
5577
5578
5579
5580
5581
5582
5583
5584
5585
5586
5587
5588
5589
5590
5591
5592
5593
5594
5595
5596
5597
5598
5599
5600
5601
5602
5603
5604
5605
5606
5607
5608
5609
5610
5611
5612
5613
5614
5615
5616
5617
5618
5619
5620
5621
5622
5623
5624
5625
5626
5627
5628
5629
5630
5631
5632
5633
5634
5635
5636
5637
5638
5639
5640
5641
5642
5643
5644
5645
5646
5647
5648
5649
5650
5651
5652
5653
5654
5655
5656
5657
5658
5659
5660
5661
5662
5663
5664
5665
5666
5667
5668
5669
5670
5671
5672
5673
5674
5675
5676
5677
5678
5679
5680
5681
5682
5683
5684
5685
5686
5687
5688
5689
5690
5691
5692
5693
5694
5695
5696
5697
5698
5699
5700
5701
5702
5703
5704
5705
5706
5707
5708
5709
5710
5711
5712
5713
5714
5715
5716
5717
5718
5719
5720
5721
5722
5723
5724
5725
5726
5727
5728
5729
5730
5731
5732
5733
5734
5735
5736
5737
5738
5739
5740
5741
5742
5743
5744
5745
5746
5747
5748
5749
5750
5751
5752
5753
5754
5755
5756
5757
5758
5759
5760
5761
5762
5763
5764
5765
5766
5767
5768
5769
5770
5771
5772
5773
5774
5775
5776
5777
5778
5779
5780
5781
5782
5783
5784
5785
5786
5787
5788
5789
5790
5791
5792
5793
5794
5795
5796
5797
5798
5799
5800
5801
5802
5803
5804
5805
5806
5807
5808
5809
5810
5811
5812
5813
5814
5815
5816
5817
5818
5819
5820
5821
5822
5823
5824
5825
5826
5827
5828
5829
5830
5831
5832
5833
5834
5835
5836
5837
5838
5839
5840
5841
5842
5843
5844
5845
5846
5847
5848
5849
5850
5851
5852
5853
5854
5855
5856
5857
5858
5859
5860
5861
5862
5863
5864
5865
5866
5867
5868
5869
5870
5871
5872
5873
5874
5875
5876
5877
5878
5879
5880
5881
5882
5883
5884
5885
5886
5887
5888
5889
5890
5891
5892
5893
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5904
5905
5906
5907
5908
5909
5910
5911
5912
5913
5914
5915
5916
5917
5918
5919
5920
5921
5922
5923
5924
5925
5926
5927
5928
5929
5930
5931
5932
5933
5934
5935
5936
5937
5938
5939
5940
5941
5942
5943
5944
5945
5946
5947
5948
5949
5950
5951
5952
5953
5954
5955
5956
5957
5958
5959
5960
5961
5962
5963
5964
5965
5966
5967
5968
5969
5970
5971
5972
5973
5974
5975
5976
5977
5978
5979
5980
5981
5982
5983
5984
5985
5986
5987
5988
5989
5990
5991
5992
5993
5994
5995
5996
5997
5998
5999
6000
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6114
6115
6116
6117
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
6148
6149
6150
6151
6152
6153
6154
6155
6156
6157
6158
6159
6160
6161
6162
6163
6164
6165
6166
6167
6168
6169
6170
6171
6172
6173
6174
6175
6176
6177
6178
6179
6180
6181
6182
6183
6184
6185
6186
6187
6188
6189
6190
6191
6192
6193
6194
6195
6196
6197
6198
6199
6200
6201
6202
6203
6204
6205
6206
6207
6208
6209
6210
6211
6212
6213
6214
6215
6216
6217
6218
6219
6220
6221
6222
6223
6224
6225
6226
6227
6228
6229
6230
6231
6232
6233
6234
6235
6236
6237
6238
6239
6240
6241
6242
6243
6244
6245
6246
6247
6248
6249
6250
6251
6252
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296
6297
6298
6299
6300
6301
6302
6303
6304
6305
6306
6307
6308
6309
6310
6311
6312
6313
6314
6315
6316
6317
6318
6319
6320
6321
6322
6323
6324
6325
6326
6327
6328
6329
6330
6331
6332
6333
6334
6335
6336
6337
6338
6339
6340
6341
6342
6343
6344
6345
6346
6347
6348
6349
6350
6351
6352
6353
6354
6355
6356
6357
6358
6359
6360
6361
6362
6363
6364
6365
6366
6367
6368
6369
6370
6371
6372
6373
6374
6375
6376
6377
6378
6379
6380
6381
6382
6383
6384
6385
6386
6387
6388
6389
6390
6391
6392
6393
6394
6395
6396
6397
6398
6399
6400
6401
6402
6403
6404
6405
6406
6407
6408
6409
6410
6411
6412
6413
6414
6415
6416
6417
6418
6419
6420
6421
6422
6423
6424
6425
6426
6427
6428
6429
6430
6431
6432
6433
6434
6435
6436
6437
6438
6439
6440
6441
6442
6443
6444
6445
6446
6447
6448
6449
6450
6451
6452
6453
6454
6455
6456
6457
6458
6459
6460
6461
6462
6463
6464
6465
6466
6467
6468
6469
6470
6471
6472
6473
6474
6475
6476
6477
6478
6479
6480
6481
6482
6483
6484
6485
6486
6487
6488
6489
6490
6491
6492
6493
6494
6495
6496
6497
6498
6499
6500
6501
6502
6503
6504
6505
6506
6507
6508
6509
6510
6511
6512
6513
6514
6515
6516
6517
6518
6519
6520
6521
6522
6523
6524
6525
6526
6527
6528
6529
6530
6531
6532
6533
6534
6535
6536
6537
6538
6539
6540
6541
6542
6543
6544
6545
6546
6547
6548
6549
6550
6551
6552
6553
6554
6555
6556
6557
6558
6559
6560
6561
6562
6563
6564
6565
6566
6567
6568
6569
6570
6571
6572
6573
6574
6575
6576
6577
6578
6579
6580
6581
6582
6583
6584
6585
6586
6587
6588
6589
6590
6591
6592
6593
6594
6595
6596
6597
6598
6599
6600
6601
6602
6603
6604
6605
6606
6607
6608
6609
6610
6611
6612
6613
6614
6615
6616
6617
6618
6619
6620
6621
6622
6623
6624
6625
6626
6627
6628
6629
6630
6631
6632
6633
6634
6635
6636
6637
6638
6639
6640
6641
6642
6643
6644
6645
6646
6647
6648
6649
6650
6651
6652
6653
6654
6655
6656
6657
6658
6659
6660
6661
6662
6663
6664
6665
6666
6667
6668
6669
6670
6671
6672
6673
6674
6675
6676
6677
6678
6679
6680
6681
6682
6683
6684
6685
6686
6687
6688
6689
6690
6691
6692
6693
6694
6695
6696
6697
6698
6699
6700
6701
6702
6703
6704
6705
6706
6707
6708
6709
6710
6711
6712
6713
6714
6715
6716
6717
6718
6719
6720
6721
6722
6723
6724
6725
6726
6727
6728
6729
6730
6731
6732
6733
6734
6735
6736
6737
6738
6739
6740
6741
6742
6743
6744
6745
6746
6747
6748
6749
6750
6751
6752
6753
6754
6755
6756
6757
6758
6759
6760
6761
6762
6763
6764
6765
6766
6767
6768
6769
6770
6771
6772
6773
6774
6775
6776
6777
6778
6779
6780
6781
6782
6783
6784
6785
6786
6787
6788
6789
6790
6791
6792
6793
6794
6795
6796
6797
6798
6799
6800
6801
6802
6803
6804
6805
6806
6807
6808
6809
6810
6811
6812
6813
6814
6815
6816
6817
6818
6819
6820
6821
6822
6823
6824
6825
6826
6827
6828
6829
6830
6831
6832
6833
6834
6835
6836
6837
6838
6839
6840
6841
6842
6843
6844
6845
6846
6847
6848
6849
6850
6851
6852
6853
6854
6855
6856
6857
6858
6859
6860
6861
6862
6863
6864
6865
6866
6867
6868
6869
6870
6871
6872
6873
6874
6875
6876
6877
6878
6879
6880
6881
6882
6883
6884
6885
6886
6887
6888
6889
6890
6891
6892
6893
6894
6895
6896
6897
6898
6899
6900
6901
6902
6903
6904
6905
6906
6907
6908
6909
6910
6911
6912
6913
6914
6915
6916
6917
6918
6919
6920
6921
6922
6923
6924
6925
6926
6927
6928
6929
6930
6931
6932
6933
6934
6935
6936
6937
6938
6939
6940
6941
6942
6943
6944
6945
6946
6947
6948
6949
6950
6951
6952
6953
6954
6955
6956
6957
6958
6959
6960
6961
6962
6963
6964
6965
6966
6967
6968
6969
6970
6971
6972
6973
6974
6975
6976
6977
6978
6979
6980
6981
6982
6983
6984
6985
6986
6987
6988
6989
6990
6991
6992
6993
6994
6995
6996
6997
6998
6999
7000
7001
7002
7003
7004
7005
7006
7007
7008
7009
7010
7011
7012
7013
7014
7015
7016
7017
7018
7019
7020
7021
7022
7023
7024
7025
7026
7027
7028
7029
7030
7031
7032
7033
7034
7035
7036
7037
7038
7039
7040
7041
7042
7043
7044
7045
7046
7047
7048
7049
7050
7051
7052
7053
7054
7055
7056
7057
7058
7059
7060
7061
7062
7063
7064
7065
7066
7067
7068
7069
7070
7071
7072
7073
7074
7075
7076
7077
7078
7079
7080
7081
7082
7083
7084
7085
7086
7087
7088
7089
7090
7091
7092
7093
7094
7095
7096
7097
7098
7099
7100
7101
7102
7103
7104
7105
7106
7107
7108
7109
7110
7111
7112
7113
7114
7115
7116
7117
7118
7119
7120
7121
7122
7123
7124
7125
7126
7127
7128
7129
7130
7131
7132
7133
7134
7135
7136
7137
7138
7139
7140
7141
7142
7143
7144
7145
7146
7147
7148
7149
7150
7151
7152
7153
7154
7155
7156
7157
7158
7159
7160
7161
7162
7163
7164
7165
7166
7167
7168
7169
7170
7171
7172
7173
7174
7175
7176
7177
7178
7179
7180
7181
7182
7183
7184
7185
7186
7187
7188
7189
7190
7191
7192
7193
7194
7195
7196
7197
7198
7199
7200
7201
7202
7203
7204
7205
7206
7207
7208
7209
7210
7211
7212
7213
7214
7215
7216
7217
7218
7219
7220
7221
7222
7223
7224
7225
7226
7227
7228
7229
7230
7231
7232
7233
7234
7235
7236
7237
7238
7239
7240
7241
7242
7243
7244
7245
7246
7247
7248
7249
7250
7251
7252
7253
7254
7255
7256
7257
7258
7259
7260
7261
7262
7263
7264
7265
7266
7267
7268
7269
7270
7271
7272
7273
7274
7275
7276
7277
7278
7279
7280
7281
7282
7283
7284
7285
7286
7287
7288
7289
7290
7291
7292
7293
7294
7295
7296
7297
7298
7299
7300
7301
7302
7303
7304
7305
7306
7307
7308
7309
7310
7311
7312
7313
7314
7315
7316
7317
7318
7319
7320
7321
7322
7323
7324
7325
7326
7327
7328
7329
7330
7331
7332
7333
7334
7335
7336
7337
7338
7339
7340
7341
7342
7343
7344
7345
7346
7347
7348
7349
7350
7351
7352
7353
7354
7355
7356
7357
7358
7359
7360
7361
7362
7363
7364
7365
7366
7367
7368
7369
7370
7371
7372
7373
7374
7375
7376
7377
7378
7379
7380
7381
7382
7383
7384
7385
7386
7387
7388
7389
7390
7391
7392
7393
7394
7395
7396
7397
7398
7399
7400
7401
7402
7403
7404
7405
7406
7407
7408
7409
7410
7411
7412
7413
7414
7415
7416
7417
7418
7419
7420
7421
7422
7423
7424
7425
7426
7427
7428
7429
7430
7431
7432
7433
7434
7435
7436
7437
7438
7439
7440
7441
7442
7443
7444
7445
7446
7447
7448
7449
7450
7451
7452
7453
7454
7455
7456
7457
7458
7459
7460
7461
7462
7463
7464
7465
7466
7467
7468
7469
7470
7471
7472
7473
7474
7475
7476
7477
7478
7479
7480
7481
7482
7483
7484
7485
7486
7487
7488
7489
7490
7491
7492
7493
7494
7495
7496
7497
7498
7499
7500
7501
7502
7503
7504
7505
7506
7507
7508
7509
7510
7511
7512
7513
7514
7515
7516
7517
7518
7519
7520
7521
7522
7523
7524
7525
7526
7527
7528
7529
7530
7531
7532
7533
7534
7535
7536
7537
7538
7539
7540
7541
7542
7543
7544
7545
7546
7547
7548
7549
7550
7551
7552
7553
7554
7555
7556
7557
7558
7559
7560
7561
7562
7563
7564
7565
7566
7567
7568
7569
7570
7571
7572
7573
7574
7575
7576
7577
7578
7579
7580
7581
7582
7583
7584
7585
7586
7587
7588
7589
7590
7591
7592
7593
7594
7595
7596
7597
7598
7599
7600
7601
7602
7603
7604
7605
7606
7607
7608
7609
7610
7611
7612
7613
7614
7615
7616
7617
7618
7619
7620
7621
7622
7623
7624
7625
7626
7627
7628
7629
7630
7631
7632
7633
7634
7635
7636
7637
7638
7639
7640
7641
7642
7643
7644
7645
7646
7647
7648
7649
7650
7651
7652
7653
7654
7655
7656
7657
7658
7659
7660
7661
7662
7663
7664
7665
7666
7667
7668
7669
7670
7671
7672
7673
7674
7675
7676
7677
7678
7679
7680
7681
7682
7683
7684
7685
7686
7687
7688
7689
7690
7691
7692
7693
7694
7695
7696
7697
7698
7699
7700
7701
7702
7703
7704
7705
7706
7707
7708
7709
7710
7711
7712
7713
7714
7715
7716
7717
7718
7719
7720
7721
7722
7723
7724
7725
7726
7727
7728
7729
7730
7731
7732
7733
7734
7735
7736
7737
7738
7739
7740
7741
7742
7743
7744
7745
7746
7747
7748
7749
7750
7751
7752
7753
7754
7755
7756
7757
7758
7759
7760
7761
7762
7763
7764
7765
7766
7767
7768
7769
7770
7771
7772
7773
7774
7775
7776
7777
7778
7779
7780
7781
7782
7783
7784
7785
7786
7787
7788
7789
7790
7791
7792
7793
7794
7795
7796
7797
7798
7799
7800
7801
7802
7803
7804
7805
7806
7807
7808
7809
7810
7811
7812
7813
7814
7815
7816
7817
7818
7819
7820
7821
7822
7823
7824
7825
7826
7827
7828
7829
7830
7831
7832
7833
7834
7835
7836
7837
7838
7839
7840
7841
7842
7843
7844
7845
7846
7847
7848
7849
7850
7851
7852
7853
7854
7855
7856
7857
7858
7859
7860
7861
7862
7863
7864
7865
7866
7867
7868
7869
7870
7871
7872
7873
7874
7875
7876
7877
7878
7879
7880
7881
7882
7883
7884
7885
7886
7887
7888
7889
7890
7891
7892
7893
7894
7895
7896
7897
7898
7899
7900
7901
7902
7903
7904
7905
7906
7907
7908
7909
7910
7911
7912
7913
7914
7915
7916
7917
7918
7919
7920
7921
7922
7923
7924
7925
7926
7927
7928
7929
7930
7931
7932
7933
7934
7935
7936
7937
7938
7939
7940
7941
7942
7943
7944
7945
7946
7947
7948
7949
7950
7951
7952
7953
7954
7955
7956
7957
7958
7959
7960
7961
7962
7963
7964
7965
7966
7967
7968
7969
7970
7971
7972
7973
7974
7975
7976
7977
7978
7979
7980
7981
7982
7983
7984
7985
7986
7987
7988
7989
7990
7991
7992
7993
7994
7995
7996
7997
7998
7999
8000
8001
8002
8003
8004
8005
8006
8007
8008
8009
8010
8011
8012
8013
8014
8015
8016
8017
8018
8019
8020
8021
8022
8023
8024
8025
8026
8027
8028
8029
8030
8031
8032
8033
8034
8035
8036
8037
8038
8039
8040
8041
8042
8043
8044
8045
8046
8047
8048
8049
8050
8051
8052
8053
8054
8055
8056
8057
8058
8059
8060
8061
8062
8063
8064
8065
8066
8067
8068
8069
8070
8071
8072
8073
8074
8075
8076
8077
8078
8079
8080
8081
8082
8083
8084
8085
8086
8087
8088
8089
8090
8091
8092
8093
8094
8095
8096
8097
8098
8099
8100
8101
8102
8103
8104
8105
8106
8107
8108
8109
8110
8111
8112
8113
8114
8115
8116
8117
8118
8119
8120
8121
8122
8123
8124
8125
8126
8127
8128
8129
8130
8131
8132
8133
8134
8135
8136
8137
8138
8139
8140
8141
8142
8143
8144
8145
8146
8147
8148
8149
8150
8151
8152
8153
8154
8155
8156
8157
8158
8159
8160
8161
8162
8163
8164
8165
8166
8167
8168
8169
8170
8171
8172
8173
8174
8175
8176
8177
8178
8179
8180
8181
8182
8183
8184
8185
8186
8187
8188
8189
8190
8191
8192
8193
8194
8195
8196
8197
8198
8199
8200
8201
8202
8203
8204
8205
8206
8207
8208
8209
8210
8211
8212
8213
8214
8215
8216
8217
8218
8219
8220
8221
8222
8223
8224
8225
8226
8227
8228
8229
8230
8231
8232
8233
8234
8235
8236
8237
8238
8239
8240
8241
8242
8243
8244
8245
8246
8247
8248
8249
8250
8251
8252
8253
8254
8255
8256
8257
8258
8259
8260
8261
8262
8263
8264
8265
8266
8267
8268
8269
8270
8271
8272
8273
8274
8275
8276
8277
8278
8279
8280
8281
8282
8283
8284
8285
8286
8287
8288
8289
8290
8291
8292
8293
8294
8295
8296
8297
8298
8299
8300
8301
8302
8303
8304
8305
8306
8307
8308
8309
8310
8311
8312
8313
8314
8315
8316
8317
8318
8319
8320
8321
8322
8323
8324
8325
8326
8327
8328
8329
8330
8331
8332
8333
8334
8335
8336
8337
8338
8339
8340
8341
8342
8343
8344
8345
8346
8347
8348
8349
8350
8351
8352
8353
8354
8355
8356
8357
8358
8359
8360
8361
8362
8363
8364
8365
8366
8367
8368
8369
8370
8371
8372
8373
8374
8375
8376
8377
8378
8379
8380
8381
8382
8383
8384
8385
8386
8387
8388
8389
8390
8391
8392
8393
8394
8395
8396
8397
8398
8399
8400
8401
8402
8403
8404
8405
8406
8407
8408
8409
8410
8411
8412
8413
8414
8415
8416
8417
8418
8419
8420
8421
8422
8423
8424
8425
8426
8427
8428
8429
8430
8431
8432
8433
8434
8435
8436
8437
8438
8439
8440
8441
8442
8443
8444
8445
8446
8447
8448
8449
8450
8451
8452
8453
8454
8455
8456
8457
8458
8459
8460
8461
8462
8463
8464
8465
8466
8467
8468
8469
8470
8471
8472
8473
8474
8475
8476
8477
8478
8479
8480
8481
8482
8483
8484
8485
8486
8487
8488
8489
8490
8491
8492
8493
8494
8495
8496
8497
8498
8499
8500
8501
8502
8503
8504
8505
8506
8507
8508
8509
8510
8511
8512
8513
8514
8515
8516
8517
8518
8519
8520
8521
8522
8523
8524
8525
8526
8527
8528
8529
8530
8531
8532
8533
8534
8535
8536
8537
8538
8539
8540
8541
8542
8543
8544
8545
8546
8547
8548
8549
8550
8551
8552
8553
8554
8555
8556
8557
8558
8559
8560
8561
8562
8563
8564
8565
8566
8567
8568
8569
8570
8571
8572
8573
8574
8575
8576
8577
8578
8579
8580
8581
8582
8583
8584
8585
8586
8587
8588
8589
8590
8591
8592
8593
8594
8595
8596
8597
8598
8599
8600
8601
8602
8603
8604
8605
8606
8607
8608
8609
8610
8611
8612
8613
8614
8615
8616
8617
8618
8619
8620
8621
8622
8623
8624
8625
8626
8627
8628
8629
8630
8631
8632
8633
8634
8635
8636
8637
8638
8639
8640
8641
8642
8643
8644
8645
8646
8647
8648
8649
8650
8651
8652
8653
8654
8655
8656
8657
8658
8659
8660
8661
8662
8663
8664
8665
8666
8667
8668
8669
8670
8671
8672
8673
8674
8675
8676
8677
8678
8679
8680
8681
8682
8683
8684
8685
8686
8687
8688
8689
8690
8691
8692
8693
8694
8695
8696
8697
8698
8699
8700
8701
8702
8703
8704
8705
8706
8707
8708
8709
8710
8711
8712
8713
8714
8715
8716
8717
8718
8719
8720
8721
8722
8723
8724
8725
8726
8727
8728
8729
8730
8731
8732
8733
8734
8735
8736
8737
8738
8739
8740
8741
8742
8743
8744
8745
8746
8747
8748
8749
8750
8751
8752
8753
8754
8755
8756
8757
8758
8759
8760
8761
8762
8763
8764
8765
8766
8767
8768
8769
8770
8771
8772
8773
8774
8775
8776
8777
8778
8779
8780
8781
8782
8783
8784
8785
8786
8787
8788
8789
8790
8791
8792
8793
8794
8795
8796
8797
8798
8799
8800
8801
8802
8803
8804
8805
8806
8807
8808
8809
8810
8811
8812
8813
8814
8815
8816
8817
8818
8819
8820
8821
8822
8823
8824
8825
8826
8827
8828
8829
8830
8831
8832
8833
8834
8835
8836
8837
8838
8839
8840
8841
8842
8843
8844
8845
8846
8847
8848
8849
8850
8851
8852
8853
8854
8855
8856
8857
8858
8859
8860
8861
8862
8863
8864
8865
8866
8867
8868
8869
8870
8871
8872
8873
8874
8875
8876
8877
8878
8879
8880
8881
8882
8883
8884
8885
8886
8887
8888
8889
8890
8891
8892
8893
8894
8895
8896
8897
8898
8899
8900
8901
8902
8903
8904
8905
8906
8907
8908
8909
8910
8911
8912
8913
8914
8915
8916
8917
8918
8919
8920
8921
8922
8923
8924
8925
8926
8927
8928
8929
8930
8931
8932
8933
8934
8935
8936
8937
8938
8939
8940
8941
8942
8943
8944
8945
8946
8947
8948
8949
8950
8951
8952
8953
8954
8955
8956
8957
8958
8959
8960
8961
8962
8963
8964
8965
8966
8967
8968
8969
8970
8971
8972
8973
8974
8975
8976
8977
8978
8979
8980
8981
8982
8983
8984
8985
8986
8987
8988
8989
8990
8991
8992
8993
8994
8995
8996
8997
8998
8999
9000
9001
9002
9003
9004
9005
9006
9007
9008
9009
9010
9011
9012
9013
9014
9015
9016
9017
9018
9019
9020
9021
9022
9023
9024
9025
9026
9027
9028
9029
9030
9031
9032
9033
9034
9035
9036
9037
9038
9039
9040
9041
9042
9043
9044
9045
9046
9047
9048
9049
9050
9051
9052
9053
9054
9055
9056
9057
9058
9059
9060
9061
9062
9063
9064
9065
9066
9067
9068
9069
9070
9071
9072
9073
9074
9075
9076
9077
9078
9079
9080
9081
9082
9083
9084
9085
9086
9087
9088
9089
9090
9091
9092
9093
9094
9095
9096
9097
9098
9099
9100
9101
9102
9103
9104
9105
9106
9107
9108
9109
9110
9111
9112
9113
9114
9115
9116
9117
9118
9119
9120
9121
9122
9123
9124
9125
9126
9127
9128
9129
9130
9131
9132
9133
9134
9135
9136
9137
9138
9139
9140
9141
9142
9143
9144
9145
9146
9147
9148
9149
9150
9151
9152
9153
9154
9155
9156
9157
9158
9159
9160
9161
9162
9163
9164
9165
9166
9167
9168
9169
9170
9171
9172
9173
9174
9175
9176
9177
9178
9179
9180
9181
9182
9183
9184
9185
9186
9187
9188
9189
9190
9191
9192
9193
9194
9195
9196
9197
9198
9199
9200
9201
9202
9203
9204
9205
9206
9207
9208
9209
9210
9211
9212
9213
9214
9215
9216
9217
9218
9219
9220
9221
9222
9223
9224
9225
9226
9227
9228
9229
9230
9231
9232
9233
9234
9235
9236
9237
9238
9239
9240
9241
9242
9243
9244
9245
9246
9247
9248
9249
9250
9251
9252
9253
9254
9255
9256
9257
9258
9259
9260
9261
9262
9263
9264
9265
9266
9267
9268
9269
9270
9271
9272
9273
9274
9275
9276
9277
9278
9279
9280
9281
9282
9283
9284
9285
9286
9287
9288
9289
9290
9291
9292
9293
9294
9295
9296
9297
9298
9299
9300
9301
9302
9303
9304
9305
9306
9307
9308
9309
9310
9311
9312
9313
9314
9315
9316
9317
9318
9319
9320
9321
9322
9323
9324
9325
9326
9327
9328
9329
9330
9331
9332
9333
9334
9335
9336
9337
9338
9339
9340
9341
9342
9343
9344
9345
9346
9347
9348
9349
9350
9351
9352
9353
9354
9355
9356
9357
9358
9359
9360
9361
9362
9363
9364
9365
9366
9367
9368
9369
9370
9371
9372
9373
9374
9375
9376
9377
9378
9379
9380
9381
9382
9383
9384
9385
9386
9387
9388
9389
9390
9391
9392
9393
9394
9395
9396
9397
9398
9399
9400
9401
9402
9403
9404
9405
9406
9407
9408
9409
9410
9411
9412
9413
9414
9415
9416
9417
9418
9419
9420
9421
9422
9423
9424
9425
9426
9427
9428
9429
9430
9431
9432
9433
9434
9435
9436
9437
9438
9439
9440
9441
9442
9443
9444
9445
9446
9447
9448
9449
9450
9451
9452
9453
9454
9455
9456
9457
9458
9459
9460
9461
9462
9463
9464
9465
9466
9467
9468
9469
9470
9471
9472
9473
9474
9475
9476
9477
9478
9479
9480
9481
9482
9483
9484
9485
9486
9487
9488
9489
9490
9491
9492
9493
9494
9495
9496
9497
9498
9499
9500
9501
9502
9503
9504
9505
9506
9507
9508
9509
9510
9511
9512
9513
9514
9515
9516
9517
9518
9519
9520
9521
9522
9523
9524
9525
9526
9527
9528
9529
9530
9531
9532
9533
9534
9535
9536
9537
9538
9539
9540
9541
9542
9543
9544
9545
9546
9547
9548
9549
9550
9551
9552
9553
9554
9555
9556
9557
9558
9559
9560
9561
9562
9563
9564
9565
9566
9567
9568
9569
9570
9571
9572
9573
9574
9575
9576
9577
9578
9579
9580
9581
9582
9583
9584
9585
9586
9587
9588
9589
9590
9591
9592
9593
9594
9595
9596
9597
9598
9599
9600
9601
9602
9603
9604
9605
9606
9607
9608
9609
9610
9611
9612
9613
9614
9615
9616
9617
9618
9619
9620
9621
9622
9623
9624
9625
9626
9627
9628
9629
9630
9631
9632
9633
9634
9635
9636
9637
9638
9639
9640
9641
9642
9643
9644
9645
9646
9647
9648
9649
9650
9651
9652
9653
9654
9655
9656
9657
9658
9659
9660
9661
9662
9663
9664
9665
9666
9667
9668
9669
9670
9671
9672
9673
9674
9675
9676
9677
9678
9679
9680
9681
9682
9683
9684
9685
9686
9687
9688
9689
9690
9691
9692
9693
9694
9695
9696
9697
9698
9699
9700
9701
9702
9703
9704
9705
9706
9707
9708
9709
9710
9711
9712
9713
9714
9715
9716
9717
9718
9719
9720
9721
9722
9723
9724
9725
9726
9727
9728
9729
9730
9731
9732
9733
9734
9735
9736
9737
9738
9739
9740
9741
9742
9743
9744
9745
9746
9747
9748
9749
9750
9751
9752
9753
9754
9755
9756
9757
9758
9759
9760
9761
9762
9763
9764
9765
9766
9767
9768
9769
9770
9771
9772
9773
9774
9775
9776
9777
9778
9779
9780
9781
9782
9783
9784
9785
9786
9787
9788
9789
9790
9791
9792
9793
9794
9795
9796
9797
9798
9799
9800
9801
9802
9803
9804
9805
9806
9807
9808
9809
9810
9811
9812
9813
9814
9815
9816
9817
9818
9819
9820
9821
9822
9823
9824
9825
9826
9827
9828
9829
9830
9831
9832
9833
9834
9835
9836
9837
9838
9839
9840
9841
9842
9843
9844
9845
9846
9847
9848
9849
9850
9851
9852
9853
9854
9855
9856
9857
9858
9859
9860
9861
9862
9863
9864
9865
9866
9867
9868
9869
9870
9871
9872
9873
9874
9875
9876
9877
9878
9879
9880
9881
9882
9883
9884
9885
9886
9887
9888
9889
9890
9891
9892
9893
9894
9895
9896
9897
9898
9899
9900
9901
9902
9903
9904
9905
9906
9907
9908
9909
9910
9911
9912
9913
9914
9915
9916
9917
9918
9919
9920
9921
9922
9923
9924
9925
9926
9927
9928
9929
9930
9931
9932
9933
9934
9935
9936
9937
9938
9939
9940
9941
9942
9943
9944
9945
9946
9947
9948
9949
9950
9951
9952
9953
9954
9955
9956
9957
9958
9959
9960
9961
9962
9963
9964
9965
9966
9967
9968
9969
9970
9971
9972
9973
9974
9975
9976
9977
9978
9979
9980
9981
9982
9983
9984
9985
9986
9987
9988
9989
9990
9991
9992
9993
9994
9995
9996
9997
9998
9999
10000
10001
10002
10003
10004
10005
10006
10007
10008
10009
10010
10011
10012
10013
10014
10015
10016
10017
10018
10019
10020
10021
10022
10023
10024
10025
10026
10027
10028
10029
10030
10031
10032
10033
10034
10035
10036
10037
10038
10039
10040
10041
10042
10043
10044
10045
10046
10047
10048
10049
10050
10051
10052
10053
10054
10055
10056
10057
10058
10059
10060
10061
10062
10063
10064
10065
10066
10067
10068
10069
10070
10071
10072
10073
10074
10075
10076
10077
10078
10079
10080
10081
10082
10083
10084
10085
10086
10087
10088
10089
10090
10091
10092
10093
10094
10095
10096
10097
10098
10099
10100
10101
10102
10103
10104
10105
10106
10107
10108
10109
10110
10111
10112
10113
10114
10115
10116
10117
10118
10119
10120
10121
10122
10123
10124
10125
10126
10127
10128
10129
10130
10131
10132
10133
10134
10135
10136
10137
10138
10139
10140
10141
10142
10143
10144
10145
10146
10147
10148
10149
10150
10151
10152
10153
10154
10155
10156
10157
10158
10159
10160
10161
10162
10163
10164
10165
10166
10167
10168
10169
10170
10171
10172
10173
10174
10175
10176
10177
10178
10179
10180
10181
10182
10183
10184
10185
10186
10187
10188
10189
10190
10191
10192
10193
10194
10195
10196
10197
10198
10199
10200
10201
10202
10203
10204
10205
10206
10207
10208
10209
10210
10211
10212
10213
10214
10215
10216
10217
10218
10219
10220
10221
10222
10223
10224
10225
10226
10227
10228
10229
10230
10231
10232
10233
10234
10235
10236
10237
10238
10239
10240
10241
10242
10243
10244
10245
10246
10247
10248
10249
10250
10251
10252
10253
10254
10255
10256
10257
10258
10259
10260
10261
10262
10263
10264
10265
10266
10267
10268
10269
10270
10271
10272
10273
10274
10275
10276
10277
10278
10279
10280
10281
10282
10283
10284
10285
10286
10287
10288
10289
10290
10291
10292
10293
10294
10295
10296
10297
10298
10299
10300
10301
10302
10303
10304
10305
10306
10307
10308
10309
10310
10311
10312
10313
10314
10315
10316
10317
10318
10319
10320
10321
10322
10323
10324
10325
10326
10327
10328
10329
10330
10331
10332
10333
10334
10335
10336
10337
10338
10339
10340
10341
10342
10343
10344
10345
10346
10347
10348
10349
10350
10351
10352
10353
10354
10355
10356
10357
10358
10359
10360
10361
10362
10363
10364
10365
10366
10367
10368
10369
10370
10371
10372
10373
10374
10375
10376
10377
10378
10379
10380
10381
10382
10383
10384
10385
10386
10387
10388
10389
10390
10391
10392
10393
10394
10395
10396
10397
10398
10399
10400
10401
10402
10403
10404
10405
10406
10407
10408
10409
10410
10411
10412
10413
10414
10415
10416
10417
10418
10419
10420
10421
10422
10423
10424
10425
10426
10427
10428
10429
10430
10431
10432
10433
10434
10435
10436
10437
10438
10439
10440
10441
10442
10443
10444
10445
10446
10447
10448
10449
10450
10451
10452
10453
10454
10455
10456
10457
10458
10459
10460
10461
10462
10463
10464
10465
10466
10467
10468
10469
10470
10471
10472
10473
10474
10475
10476
10477
10478
10479
10480
10481
10482
10483
10484
10485
10486
10487
10488
10489
10490
10491
10492
10493
10494
10495
10496
10497
10498
10499
10500
10501
10502
10503
10504
10505
10506
10507
10508
10509
10510
10511
10512
10513
10514
10515
10516
10517
10518
10519
10520
10521
10522
10523
10524
10525
10526
10527
10528
10529
10530
10531
10532
10533
10534
10535
10536
10537
10538
10539
10540
10541
10542
10543
10544
10545
10546
10547
10548
10549
10550
10551
10552
10553
10554
10555
10556
10557
10558
10559
10560
10561
10562
10563
10564
10565
10566
10567
10568
10569
10570
10571
10572
10573

-- *****************************************************************
-- MUSARUBRA CONFIDENTIAL
-- TRELLIX-SENSOR-CONF-MIB:
-- Trellix (Sensor Configuration MIB)
--
-- Copyright (c) 2022 MUSARUBRA US, LLC
-- All rights reserved.
--
-- *****************************************************************

TRELLIX-SENSOR-CONF-MIB DEFINITIONS ::= BEGIN

IMPORTS
	OBJECT-TYPE, MODULE-IDENTITY, Integer32, 
	IpAddress, TimeTicks, Unsigned32
		FROM SNMPv2-SMI
	TimeInterval, TruthValue, RowStatus, 
	MacAddress, DateAndTime, DisplayString
		FROM SNMPv2-TC
	Ipv6Address
		FROM IPV6-TC
	ivSensorConfiguration, respPortIndex, intfPortIndex, slotIndex, intfPhysicalPortIndex, ntpServerIndex, sslProbeIpv4Index, sslProbeIpv6Index, processorNumIndex, intfVirtualPortIndex, intfVirtualSlotIndex
		FROM TRELLIX-SENSOR-SMI
	TrellixFEType, TrellixIDSOperatingMode, TrellixIDSPortType, 
	TrellixIDSResponseMode, TrellixIDSActionResult, TrellixIDSActionStatus,
	TrellixIDSAction, TrellixIDSCardType, TrellixTFTPFileType,
	TrellixTFTPFailedResult, TrellixTFTPInProgressResult, TrellixTFTPStatus,
	TrellixTFTPAction, TrellixGEType,TrellixCUGEType, TrellixPortSpeed, TrellixPluggableModuleType,
	TrellixPortLinearIndex
		FROM TRELLIX-INTRUVERT-TC;

ivSensorConfigurationMIB MODULE-IDENTITY
LAST-UPDATED "200707090000Z"
ORGANIZATION 
"MUSARUBRA US LLC"
CONTACT-INFO 
"Trellix Customer Service Department

Postal: 6220 American Center Drive
        San Jose CA 95002-2563
      

Tel: +1 800 338 8754

E-mail: support@mcafee.com"
DESCRIPTION 
"The Configuration MIB for the Trellix IntruShield product.

They are furthur broken down into the following groups:
 systemGrp - configuration of the IntruShield node identification.
 emsGrp - configuration of possible EMSs identification
 chassisGrp - configuration of the chassis slots
 managementCardGrp - configuration of the management card(s)
 tftpGrp - configuration of TFTP based services
 sensorCardGp - configuration of the sensor anlysis card(s)
 interfacePortGrp - configuration of interface port(s)
 responsePortGrp - configuration of response port(s) 
 pktLogGrp - configuration of the Packet Logging Application
 sslGrp - SSL configuration 
"

REVISION "200706140000Z"
DESCRIPTION 
"Initial version of this MIB module."
::= { ivSensorConfiguration 1 }


--This group contains objects that identify the IntruShield network element.

systemGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 1 }


ivSysName  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..80))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"An administratively assigned name for this IntruShied node.  
		By convention, this is the node's fully-qualified domain name."
	::= { systemGrp 1 }

ivSysLocation  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..255))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The physical location of this node (e.g., `Building 6, IS room 443, 3rd floor')."
	::= { systemGrp 2 }

ivSysContact  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..255))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The textual identification of the contact person for this IntruShield node, 
		together with information on how to contact this person."
	::= { systemGrp 3 }

ivSysModel  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..32))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object is where the manufacturer specifies the model identification 
		(number or type) of the network element."
	::= { systemGrp 4 }

-- Support for ivSysSerialNumber is deprecated in V-series sensors(VmIPS).
ivSysSerialNumber  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(1..80))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Manufacturer-provided serial number."
	::= { systemGrp 5 }

ivSysDescr  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..255))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"A textual description of the entity.  This value should include the full name and version
		identification of the system's hardware type, software operating system, and networking
		software.  It is current that this only contains printable ASCII characters."
	::= { systemGrp 6 }

ivSysObjectID  OBJECT-TYPE
	SYNTAX 	OBJECT IDENTIFIER
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The vendor's authoritative identification of the
		network management subsystem contained in the
		entity.  This value is allocated within the SMI
		enterprises subtree (1.3.6.1.4.1) and provides an
		easy and unambiguous means for determining `what
		kind of box' is being managed.  For example, if
		vendor `Flintstones, Inc.' was assigned the
		subtree 1.3.6.1.4.1.4242, it could assign the
		identifier 1.3.6.1.4.1.4242.1.1 to its `Fred
		Router'."
	::= { systemGrp 7 }

ivSysUpTime  OBJECT-TYPE
	SYNTAX 	TimeTicks
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The time (in hundredths of a second) since the network management portion of the system 
		was last re-initialized."
	::= { systemGrp 8 }

ivSysLastCfgTime  OBJECT-TYPE
	SYNTAX 	DateAndTime
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Indicates time when configuration was changed last."
	::= { systemGrp 9 }

-- Support for ivSysDiskSpaceLeft is deprecated in V-series sensors(VmIPS).
ivSysDiskSpaceLeft  OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Returns the numbers of kbytes left on the disk."
	::= { systemGrp 10 }

ivSysAlertChannelStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		down (0),
		up (1),
		errorInGetTimeFromManager (2),
		errorGeneratingCertificates (3),
		errorPersistingCertificates (4),
		errorConnectingToManager (5),
		errorInUntrustedConnectionSetup (6),
		errorInInstall (7),
		errorPersistingManagerPublicCertificate (8),
		errorInMutualTrustMatch (9),
		errorInSnmpKeyExchange (10),
		errorInInitialProtocolMessageExchange (11),
		sensorInstallInProgress (12),
		openingAlertChannelInProgress (13),
		errorInLinkHenceReopening (14),
		errorInChannelReopening (15),
		closingChannelInProgress (16),
		errorClosingChannel (17),
		sendAlertWarning (18),
		keepAliveWarning (19),
		errorDeletingCerts (20),
		errorCreatingSnmpUser (21),
		errorChangingSnmpUserKeys (22)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Returns the status of the alert channel connection with
		EMS."
	::= { systemGrp 11 }

ivSysPacketLogChannelStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
                down (0),
                up (1),
		errorInGetTimeFromManager (2),
		errorGeneratingCertificates (3),
		errorPersistingCertificates (4),
		errorConnectingToManager (5),
		errorInUntrustedConnectionSetup (6),
		errorInInstall (7),
		errorPersistingManagerPublicCertificate (8),
		errorInMutualTrustMatch (9),
		errorInSnmpKeyExchange (10),
		errorInInitialProtocolMessageExchange (11),
		packetLogInstallInProgress (12),
		openingPacketLogInProgress (13),
		errorInLinkHenceReopening (14),
		errorInChannelReopening (15),
		closingChannelInProgress (16),
		errorClosingChannel (17),
		sendLogWarning (18),
		keepAliveWarning (19)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Returns the status of the packet log channel connection with
		EMS."
	::= { systemGrp 12 }

ivSysHealth  OBJECT-TYPE
	SYNTAX 	INTEGER {
                bad (0),
                good (1),
                uninitialized (2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Returns the health of the sensor. uninitialized means
		that the sensor does not have signatures hence does not
		detect attacks"
	::= { systemGrp 13 }

ivSysResetPassword  OBJECT-TYPE
	SYNTAX 	INTEGER {
                not-applicable (0),
                resetPassword (1)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to reset the password back to default
		value. Returns not-applicable(0) upon read."
	::= { systemGrp 14 }

ivSysDeleteSignatures  OBJECT-TYPE
	SYNTAX 	INTEGER {
                not-applicable (0),
                deleteSignatures (1)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to delete the signatures on the sensor if present.
    This also reboots the sensor after deleting the signatures. Does nothing
    if signatures are not present. Returns not-applicable(0) upon read."
	::= { systemGrp 15 }

-- Support for ivSysSlaveSerialNumber is deprecated in V-series sensors(VmIPS).
ivSysSlaveSerialNumber  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(1..80))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Manufacturer-provided slave serial number. This is the serial number
    for a cluster-slave in a palomar cluster"
	::= { systemGrp 16 }

ivSysUIDSeed  OBJECT-TYPE
	SYNTAX 	INTEGER (0..65535)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object contains the portion of the seed value to be used for generating 
		 UIDs' for alerts and logs. In case there is a mismatch, the ISM would set the
		 right value, which would used by the sensor for new alerts and logs."
	::= { systemGrp 17 }

ivSysFipsMode OBJECT-TYPE
        SYNTAX INTEGER {
        enable (1),
        disable (2)
        }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
                "This Object holds the status of the fips mode.If the sensor is operating in FIPS
                mode then this Object will have enable value or else disable value."
        ::= { systemGrp 18 }

 ivSysNumLbPorts OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
                 "This object is set by the NSM to inform the sensors connected to the Load Balancer(LB)
                 of the number of ports on the LB switch."
        ::= { systemGrp 19 }

ivSysUpTimeNew  OBJECT-TYPE
        SYNTAX Counter64
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The time (in hundredths of a second) since the network management portion of the system
                was last re-initialized."
        ::= { systemGrp 20 }

ivSysCapacityMode OBJECT-TYPE
        SYNTAX Counter64
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "To push new license from NSM"
        ::= { systemGrp 21 }

ivSysCurrentCapacityMode OBJECT-TYPE
        SYNTAX Counter64
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
               "To get current license mode of sensor"
        ::= { systemGrp 22 }

ivSysDeviceMode OBJECT-TYPE
        SYNTAX Counter64
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "To get current device mode"
        ::= { systemGrp 23 }

ivSysConfDeviceMode OBJECT-TYPE
        SYNTAX Counter64
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "To get configured device mode"
        ::= { systemGrp 24 }

ivSysRebootStatus  OBJECT-TYPE
        SYNTAX Counter64
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "If a system reboot is required and Why
                REBOOT_DEFAULT_STATUS (0) // No Reboot Required
                REBOOT_UPGRADE_DOWNLOAD (1)
                REBOOT_SETUP_CHANGE (2)
                REBOOT_IPV6_CONFIG_CHANGE (3)
                REBOOT_SSL_MODE_CHANGE (4)
                REBOOT_JUMBOFRAMEPARSING_CONFIG_CHANGE (5)
                REBOOT_PREV_256BYTES_LOGGING_CONFIG_CHANGE (6)
                NMS_USERS_WRITE_ACCESS_CONFIG_CHANGE (7)
                REBOOT_LAYER7_DCAP_NUM_FLOWS_CHANGE (8)
                REBOOT_LAYER7_DCAP_BUFF_SIZE_CHANGE (9)
                REBOOT_LAYER7_DCAP_STATUS_CHANGE (10)
                REBOOT_SBC_CORE_INCREMENT_CONFIG_CHANGE (11)
                REBOOT_REQUIRED_MAX_SNMPD_RESTART_EXCEEDED (12)
                REBOOT_REQUIRED_SBC_TLV_ERROR (13)
                REBOOT_SNORT_CONFIG_CHANGE (15)
                REBOOT_CAPACITY_MODE_CHANGE (16)
                REBOOT_SSL_FLOWALLOC_CHANGE (17)
                "
        ::= { systemGrp 25 }

ivSysRebootReason OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object contains reason for the sensor reboot.
                 NULL is stored in the object if reboot is not required"
        ::= { systemGrp 26 }

--This group contains objects that identify the IP configuration information for the 
--IntruShield network element.
--

systemIPCfgGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 2 }

ivSysIPAddress  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object contains the IP Address of the management card on the IntruShield node,
		that interfaces with the EMS."
	::= { systemIPCfgGrp 1 }

ivSysMACAddress  OBJECT-TYPE
	SYNTAX 	MacAddress
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object contains the MAC address of the management card on the IntruShield node."
	::= { systemIPCfgGrp 2 }

ivSysSubnetMask  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object specifies the Subnet mask of the management card on the IntruShield node."
	::= { systemIPCfgGrp 3 }

ivSysGateway  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object specifies the gateway address of the management card on the IntruShield node."
	::= { systemIPCfgGrp 4 }

ivSysIPv6Address  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object contains the IPv6 Address of the management card on the IntruShield node,
		that interfaces with the EMS."
	::= { systemIPCfgGrp 5 }

ivSysIpv6SubnetMask  OBJECT-TYPE
	SYNTAX 	INTEGER (0..128)
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object specifies the number of bits that need to set to '1' from left to right,
		 int the Ipv6 address Subnet mask of the management card on the IntruShield node."
	::= { systemIPCfgGrp 6 }

ivSysIpv6Gateway  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object specifies the gateway Ipv6 address of the management card on the IntruShield node."
	::= { systemIPCfgGrp 7 }

ivSysVmHostIPAddress  OBJECT-TYPE
        SYNTAX  IpAddress
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object contains the IP Address of the Vm Host on which VIPS will be running.
		This mib object will be available only on V-series sensors."
        ::= { systemIPCfgGrp 8 }

ivSysVmHostIPv6Address  OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object contains the IP Address of the Vm Host on which VIPS will be running.
		This mib object will be available only on v-series sensors."
        ::= { systemIPCfgGrp 9 }

ivSysVmHostName  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255)) 
        MAX-ACCESS  read-only 
        STATUS  current
        DESCRIPTION
                "This object contains the Vm Host name on which VIPS will be running.
                This mib object will be available only on V-series sensors."
        ::= { systemIPCfgGrp 10 }

ivSysVmMgmtAdditionalInfo  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "A textual string containing additional information about the management interface.
                This mib object will be available only on v-series sensors."
        ::= { systemIPCfgGrp 11 }



--
-- System Failover Group
--
--This group contains objects that identify the failover configuration information for the 
--IntruShield network element.

systemFailoverGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 3 }

ivSysFailoverStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		peer-up (1),
		peer-down (2),
		peer-incompatible (3)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Indicates if IDS peer is in peer-down or peer-up mode. Default: peer-down (2)."
	::= { systemFailoverGrp 1 }

ivSysFailoverAction  OBJECT-TYPE
	SYNTAX 	INTEGER {
		on (1),
		off (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to indicate if the sensor is in failover
		configuration or not. If the sensors are in failover
		configuration, then both sensors have to be set to on(1).
		Default: off(2)"
	::= { systemFailoverGrp 2 }

ivSysFailoverMode  OBJECT-TYPE
	SYNTAX 	INTEGER {
		standalone (0),
		primary (1),
		secondary (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Added for the I-3000/I-4010 sensors.
                 This object is used to specify to the sensor if it is primary 
                 or secondary when failover is enabled.
                 This value ( 1 or 2) must be set on the sensor prior to 
                 enabling failover.
		 When failover is disabled, the sensor will automatically
                 update this object to standalone (0). 
                 The manager can opt to explicitly set this after disabling 
                 failover on the sensor, however it is not necessary.
		 Default: standalone(0), since failover is disabled"
	::= { systemFailoverGrp 3 }

ivSysFailopenAction  OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to indicate if the sensor should fail-open when
		 in failover mode.
		Default: disable(2)"
	::= { systemFailoverGrp 4 }


ivSysSTPForwardConfig  OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to indicate if the sensor should forward the STP traffic 
         through peer in failover mode.
		Default: disable(2)"
	::= { systemFailoverGrp 5 }

--
-- EmsGrp 
--
-- This group contians the <emsTable> that identifies two EMSs for this sensor
-- They are indexed by <emsIndex> and identified by their <emsIPAddress>. 
-- The only field that is writable for each EMS is the emsPriority.  All
-- the other fields are updated by the sensor itself.
--
-- An EMS can look at this emsTable to find out the status of sensors 
-- connection to EMSs.  Any changes at the EMS can be communicated to the sensor
-- using the emsChangeAction mib object.  
-- Under error scenarios like sensor getting out of sync with the EMS because it was 
-- offline when the change at EMS took place can also be corrected using the same
-- emsChangeAction mib object. 
--
--

emsGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 4 }

emsTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF EmsEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This table comprises of exactly two possible EMS entries each defined by <emsEntry>.
		
		
		"
	::= { emsGrp 1 }

emsEntry  OBJECT-TYPE
	SYNTAX 	EmsEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Each entry specified is indexed by <emsIndex>. 
		Additonaly it contains the <emsIPAddress> and <emsPriority>
		"
	INDEX { emsIndex }
	::= { emsTable 1 }

EmsEntry ::= SEQUENCE {
	emsIndex
		Integer32,
	emsPriority
		INTEGER,
	emsIPAddress
		IpAddress,
	emsHAMode
		INTEGER,
	emsHAStatus
		INTEGER,
	emsAlertChannelStatus
		INTEGER,
	emsPacketLogChannelStatus
		INTEGER,
	emsIPv6Address
		Ipv6Address,
	emsIPAddressType
		INTEGER,
	emsAuthChannelStatus
		INTEGER
}


emsIndex  OBJECT-TYPE
	SYNTAX 	Integer32 (1..2)
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Fixed index for the two EMS entries. Valid values are [1,2] only."
	::= { emsEntry 1 }


emsPriority  OBJECT-TYPE
	SYNTAX 	INTEGER {
		primary (1),
		secondary (2),
                standalone (3),
		unknown (4)
	}
	MAX-ACCESS  read-only 
	STATUS	current
	DESCRIPTION 
		"Identifies whether the EMS identifed by the IPAddress is the Primary or Secondary. This value
		is only informational from sensor point of view and is set by the EMS when we have established
		connection to it. Note that transition at EMS from Primary to Secondary or vice versa will have
		no effect on the sensor.  The only thing sensor needs to worry about while in MDR mode is the
		active/standby status.
		"
	::= { emsEntry 2 }


emsIPAddress  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"IP Address of a EMS (in this entry)."
	::= { emsEntry 3 }


emsHAMode  OBJECT-TYPE
	SYNTAX 	INTEGER {
		failover (1),
		standalone (2),
		unknown (3)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Identifies the MDR mode of the EMS.  Initially when the system comes up this would be set to
		unknown till we contact the EMS and get its MDR status. This field also gets updated when a 
		MDR-to-Standalone or Standalone-to-MDR action is triggered.
		"
	::= { emsEntry 4 }

emsHAStatus  OBJECT-TYPE
	SYNTAX  INTEGER {
 		unknown(1),
		active (2),
		standby (3)
	}
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
		"This object specifies if the EMS is an active or a standby when operating in failover mode"
	::= { emsEntry 5 }

emsAlertChannelStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		down (0),
		up (1),
		errorInGetTimeFromManager (2),
		errorGeneratingCertificates (3),
		errorPersistingCertificates (4),
		errorConnectingToManager (5),
		errorInUntrustedConnectionSetup (6),
		errorInInstall (7),
		errorPersistingManagerPublicCertificate (8),
		errorInMutualTrustMatch (9),
		errorInSnmpKeyExchange (10),
		errorInInitialProtocolMessageExchange (11),
		sensorInstallInProgress (12),
		openingAlertChannelInProgress (13),
		errorInLinkHenceReopening (14),
		errorInChannelReopening (15),
		closingChannelInProgress (16),
		errorClosingChannel (17),
		sendAlertWarning (18),
		keepAliveWarning (19),
		errorDeletingCerts (20),
		errorCreatingSnmpUser (21),
		errorChangingSnmpUserKeys (22)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Returns the status of the alert channel connection with
		EMS identifed by the emsIPAddress of this entry."
	::= {  emsEntry 6 }

emsPacketLogChannelStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
                down (0),
                up (1),
		errorInGetTimeFromManager (2),
		errorGeneratingCertificates (3),
		errorPersistingCertificates (4),
		errorConnectingToManager (5),
		errorInUntrustedConnectionSetup (6),
		errorInInstall (7),
		errorPersistingManagerPublicCertificate (8),
		errorInMutualTrustMatch (9),
		errorInSnmpKeyExchange (10),
		errorInInitialProtocolMessageExchange (11),
		packetLogInstallInProgress (12),
		openingPacketLogInProgress (13),
		errorInLinkHenceReopening (14),
		errorInChannelReopening (15),
		closingChannelInProgress (16),
		errorClosingChannel (17),
		sendLogWarning (18),
		keepAliveWarning (19)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Returns the status of the packet log channel connection with
		EMS identified by the emsIPAddress of this entry."
	::= {  emsEntry 7 }

emsIPv6Address  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"IPv6 Address of a EMS (in this entry)."
	::= { emsEntry 8 }

emsIPAddressType OBJECT-TYPE
	SYNTAX 	INTEGER {
		ip-v4 (4),
		ip-v6 (6)
	}
	MAX-ACCESS  read-only 
	STATUS	current
	DESCRIPTION 
		"Identifies the type of EMS IPAddress. If set to ip-v4, then the emsIPAddress object
		 would be set else if this object is set to ip-v6, then the empIPv6Address object 
		 would be set.
		"
	::= { emsEntry 9 }

emsAuthChannelStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		down (0),
		up (1)
	}
	MAX-ACCESS  read-only 
	STATUS	current
	DESCRIPTION 
		"Returns the status of the authentication channel connection with 
      EMS identified by the emsIPAddress of this entry."
	::= { emsEntry 10 }

emsChangeAction  OBJECT-TYPE
	SYNTAX  INTEGER {
                other (0),
		standalone-to-ha (1),
		ha-to-standalone (2),
        	switchover (3),
        	add-ism-sec-ip (4)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object is used to indicate to the sensor, changes in the EMS MDR operation mode."
	::= { emsGrp 2 }

emsParamIpAddress  OBJECT-TYPE
	SYNTAX IpAddress
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object is one of the parameters that need to be set before emsChangeAction is triggered.
		If the action is Switchover this specifies the IP address of the Manager that the sensor should switch to.
		If the action is Standalone-to-MDR this specifies the Peer EMS IP address and this will result in using
		a free entry in the emsTable. 
		If the action  is MDR-to-Standalone this specifies the future Standalone EMS IP address which should be
        	one of the two EMSs specified in the emsTable. 
		The acutal swithover or change in MDR opearation mode will be done when indicated by the Manager through the 
		emsChangeAction object.
		Setting this object would reset the emsParamIpv6Address and emsParamAddIpv6Address objects.
        "
	::= { emsGrp 3 }

emsParamPriority  OBJECT-TYPE
	SYNTAX INTEGER {
                other (0),
		primary (1),
		secondary (2),
		standalone (3)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		" This object specifies the priority of the EMS setting the standalone-to-MDR change action."
	::= { emsGrp 4 }

emsParamAddIpAddress  OBJECT-TYPE
	SYNTAX IpAddress
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
       " This object specifies the secondary IP address of the EMS while in MDR mode. If the emsChangeAction
        is standalone-to-MDR, this specifies the secondary IP address of the new peer Manager. If the 
         emsChangeAction is secondary NIC address, this specifies the secondary IP address of the EMS 
         identified by emsParamIpAddress.
	 Setting this object would reset the emsParamIpv6Address and emsParamAddIpv6Address objects."
	::= { emsGrp 5 }

emsParamIpv6Address  OBJECT-TYPE
	SYNTAX Ipv6Address
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object is one of the parameters that need to be set before emsChangeAction is triggered.
		If the action is Switchover this specifies the IPv6 address of the Manager that the sensor should switch to.
		If the action is Standalone-to-MDR this specifies the Peer EMS IPv6 address and this will result in using
		a free entry in the emsTable. 
		If the action  is MDR-to-Standalone this specifies the future Standalone EMS IPv6 address which should be
        	one of the two EMSs specified in the emsTable. 
		The acutal swithover or change in MDR opearation mode will be done when indicated by the Manager through the 
		emsChangeAction object.
		Setting this object would reset the emsParamIpAddress and emsParamAddIpAddress objects.
        "
	::= { emsGrp 6 }

emsParamAddIpv6Address  OBJECT-TYPE
	SYNTAX Ipv6Address
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
       " This object specifies the secondary IPv6 address of the EMS while in MDR mode. If the emsChangeAction
         is standalone-to-MDR, this specifies the secondary IPV6 address of the new peer Manager. If the 
         emsChangeAction is secondary NIC address, this specifies the secondary IPv6 address of the EMS 
         identified by emsParamIpAddress.
	 Setting this object would reset the emsParamIpAddress and emsParamAddIpAddress objects."
	::= { emsGrp 7 }

emsTenantId  OBJECT-TYPE
	SYNTAX OCTET STRING (SIZE(36))
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
       " This object specifies the TenantId. which identifies unique customer in Trellix eco system"
	::= { emsGrp 8 }

emsPrimaryNSMGUID  OBJECT-TYPE
	SYNTAX OCTET STRING (SIZE(36))
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
       " This object specifies the Primary NSM Server GUID. which identifies unique NSM in Trellix eco system"
	::= { emsGrp 9 }

emsSecondaryNSMGUID  OBJECT-TYPE
	SYNTAX OCTET STRING (SIZE(36))
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
       " This object specifies the Secondary NSM Server GUID. which identifies unique NSM in Trellix eco system"
	::= { emsGrp 10 }

--This group contains MIB objects for the configuration of the TFTP service.

tftpGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 5 }

tftpKey  OBJECT-TYPE
	SYNTAX 	OCTET STRING (SIZE(128))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This specifies the tftp shared secret key between the IntruShield Sensor and EMS.
		Default: All 128 octets filled with '0'."
	::= { tftpGrp 1 }

tftpFileSize  OBJECT-TYPE
	SYNTAX 	Integer32 (0..134217727)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The size of the file in bytes. Default: 0 "
	::= { tftpGrp 2 }

tftpFileName  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..128))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This specifies the name of the file to TFTP (with the source path)"
	::= { tftpGrp 3 }

tftpServerAddress  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"TFTP server IP address.
		Is the EMS address when downloading from EMS to management card.
		Setting this object would reset the tftpServerIpv6Address objects."
	::= { tftpGrp 4 }

tftpAction  OBJECT-TYPE
	SYNTAX 	TrellixTFTPAction
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Invokes TFTP service using other (required) parameters defined in <tftpGrp>.
		 Valid values are : (0)-other, (1)-downloadimage, (2)-downloadsigfile, (3)-uploaddos,
				    (4)-uploadtrace, (5)-downloaddos, (6)-aborttransfer, (7)-downloadcertfile,
				    (8)-downloadimageandsigfile, (9)-downloadmperootcertfile,
				    (10)-download_sgap_ssl_cert, (11)-upload_sgap_ssl_csr,
				    (12)-upload_ibac_ad_file, (13)-download_ibac_ad_file,
				    (14)-upload_swh_learned_file,
				    (15)-downloadPacketCaptureFilterFile ,(16)-uploadPacketCaptureFilterFile,
				    (17)-downloadGeoLocationDatabase, (18)-uploadPacketCapturePCAPFile,
					(19)-download_usrid_acl_file,
                    (20)-download-bot-dat-file,
                    (21)-download-ntba-ssl-cert-file,(22)-upload-dev-prof-file,
                    (25)-download_matd_ssl_cert, (28)-download-ffp-bulk-file,
                    (33)-download_zcenter_ssl_cert, (34)-download-gti-private-cloud-cert-file,
                    (35)-upload_suricata_failed_rules, (36)-upload_ca_sensor_csr,
                    (37)-download_ca_sensor_cert, (38)-download_syslog_ssl_cert,
                    (39)-download_ca_cert_store"
	::= { tftpGrp 5 }

tftpActionStatus  OBJECT-TYPE
	SYNTAX 	TrellixTFTPStatus
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The status of the current TFTP action"
	::= { tftpGrp 6 }

tftpActionInProgressResult  OBJECT-TYPE
	SYNTAX 	TrellixTFTPInProgressResult
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Specifies TFTP service completion percentage.
		"
	::= { tftpGrp 7 }

tftpActionFailedResult  OBJECT-TYPE
	SYNTAX 	TrellixTFTPFailedResult
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"See TrellixTFTPFailedResult"
	::= { tftpGrp 8 }

tftpActionTransactionId  OBJECT-TYPE
	SYNTAX 	INTEGER 
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Used to ensure single file transfer at a time. Default: 0."
	::= { tftpGrp 9 }

tftpServerIpv6Address  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"TFTP server IPv6 address.
		Is the EMS IPv6 address when downloading from EMS to management card. 
		Either one of the Ipv4 or Ipv6 address should be set by the ISM.
		Setting this object would reset the tftpServerIpAddress objects."
	::= { tftpGrp 10 }

tftpIVKey  OBJECT-TYPE
  SYNTAX  OCTET STRING (SIZE(128))
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
    "This specifies the tftp Initialization Vector that is used for AES Decryption between the IntruShield Sensor and EMS.
    Default: All 128 octets filled with '0'."
  ::= { tftpGrp 11 }

--Trellix IntruShield chassis.
--The chassis may be a slim line enclosure with no explicit slot concept or a larger enclosure 
--with multiple slots. 
--
--This MIB does not differentiate between the two and models all it's cards 
--as entities that can be associated with a containing slot.
-- Support for chassisGrp is deprecated in V-series sensors(VmIPS).

chassisGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 7 }


temperatureStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		normal (0),
		abnormal (1)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		""
	::= { chassisGrp 1 }

fanStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		normal (0),
		abnormal (1),
		removed (2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		""
	::= { chassisGrp 2 }

primaryPowerSupplyStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		not-present (0),
		present-operational (1),
		present-nonoperational (2),
		error (3)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This powerSupply MIB object gives the primary powerSupply status.
                   (0) - Primary PowerSupply Module is not present.
                   (1) - Primary PowerSupply Module is present and operational.
                   (2) - Primary PowerSupply Module is present and its not operational.
                   (3) - Error while retrieving the powerSupply status, please re-try after some time."
	::= { chassisGrp 3 }

secondaryPowerSupplyStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		not-present (0),
		present-operational (1),
		present-nonoperational (2),
		error (3)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This powerSupply MIB object gives the secondary powerSupply status.
                   (0) - Secondary PowerSupply Module is not present.
                   (1) - Secondary PowerSupply Module is present and operational.
                   (2) - Secondary PowerSupply Module is present and its not operational.
                   (3) - Error while retrieving the powerSupply status, please re-try after some time."
	::= { chassisGrp 4 }

pciLegacyErrorStatus OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..512))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "BMC PCI Legacy Error (parity error (PERR) and system error (SERR))"
    ::= { chassisGrp 5 }

pciFatalError1Status OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..512))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "BMC PCI Fatal Error1 Status"
    ::= { chassisGrp 6 }

pciFatalError2Status OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..512))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "BMC PCI Fatal Error2 Status (Continuation of Fatat Error 1)"
    ::= { chassisGrp 7 }

systemEventLogStatus OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..512))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "BMC System Event Log (SEL buffer) Status"
    ::= { chassisGrp 8 }

bmcWatchdogStatus OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..512))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "BMC Watchdog Status"
    ::= { chassisGrp 9 }

processorStatusTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF ProcessorStatusEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "This table contain list of processors"
    ::= { chassisGrp 10 }

processorStatusEntry OBJECT-TYPE
    SYNTAX ProcessorStatusEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The table entries denotes various processor details for each index (processor) "
    INDEX { processorNumIndex }
    ::= { processorStatusTable 1 }

ProcessorStatusEntry ::= SEQUENCE{
    processorStatus
        DisplayString,
}

processorStatus OBJECT-TYPE
    SYNTAX DisplayString (SIZE(0..512))
    MAX-ACCESS read-only
    STATUS  current
    DESCRIPTION
        "Processor Presence Status"
    ::= { processorStatusEntry 1 }

memoryECCStatus OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..512))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "Memory ECC Status"
    ::= { chassisGrp 11 }

postSysEventStatus OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..512))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "POST Sys Event Status"
    ::= { chassisGrp 12 }

postErrorStatus OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..512))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "POST Error Status"
    ::= { chassisGrp 13 }

--Trellix Sensor Slave chassis.

slave-ChassisGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 9 }

slaveTemperatureStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                normal (0),
                abnormal (1)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                ""
        ::= { slave-ChassisGrp 1 }

slaveFanStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                normal (0),
                abnormal (1)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                ""
        ::= { slave-ChassisGrp 2 }

slavePrimaryPowerSupplyStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                not-present (0),
                present-operational (1),
                present-nonoperational (2),
                error (3)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This powerSupply MIB object gives the primary powerSupply status.
                   (0) - Slave Primary PowerSupply Module is not present.
                   (1) - Slave Primary PowerSupply Module is present and operational.
                   (2) - Slave Primary PowerSupply Module is present and its not operational.
                   (3) - Error while retrieving the powerSupply status, please re-try after some time."
        ::= { slave-ChassisGrp 3 }

slaveSecondaryPowerSupplyStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                not-present (0),
                present-operational (1),
                present-nonoperational (2),
                error (3)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This powerSupply MIB object gives the secondary powerSupply status.
                   (0) - Slave Secondary PowerSupply Module is not present.
                   (1) - Slave Secondary PowerSupply Module is present and operational.
                   (2) - Slave Secondary PowerSupply Module is present and its not operational.
                   (3) - Error while retrieving the powerSupply status, please re-try after some time."
        ::= { slave-ChassisGrp 4 }

--This group conatins all MIB objects that specify the configuration of the
--Trellix IntrusShield management card.
--
--The object mgmtCardTable within this group suggest that each IntruShield chassis
--can contain more than one management card, only for standby purposes.

managementCardGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 8 }

mgmtCardTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF MgmtCardEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This table contains entries, one per management card, indexed by the appropriate slotIndex."
	::= { managementCardGrp 1 }

mgmtCardEntry  OBJECT-TYPE
	SYNTAX 	MgmtCardEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This MIB object contains all the columnar objects, 
		that describe the contents of each management card within the IntruShield node.
		This entry is indexed by a fixed value slotIndex of 1 (one) for all models."
	INDEX { slotIndex }
	::= { mgmtCardTable 1 }

MgmtCardEntry ::= SEQUENCE {
	mcAction
		TrellixIDSAction,
	mcActionStatus
		TrellixIDSActionStatus,
	mcActionResult
		TrellixIDSActionResult,
	mcHwVersion
		DisplayString,
	mcCurrentSwVersion
		DisplayString,
	mcFutureSwFileName
		DisplayString,
	mcDateAndTime
		DateAndTime
}

mcAction  OBJECT-TYPE
	SYNTAX 	TrellixIDSAction
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Actions applicable on this card, uses TC TrellixIDSAction.
		Default: other
		Only 'reset' and 'swupdate' action are supported."
	::= { mgmtCardEntry 1 }

mcActionStatus  OBJECT-TYPE
	SYNTAX 	TrellixIDSActionStatus
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Outcome of a SNMP set on the mcAction object. Uses TC TrellixIDSActionStatus
		
		Default: other"
	::= { mgmtCardEntry 2 }

mcActionResult  OBJECT-TYPE
	SYNTAX 	TrellixIDSActionResult
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Detail information when <mcAction> is set to 'reset', based on <mcActionStatus>
		
		Default: 0, details not defined."
	::= { mgmtCardEntry 3 }

-- Support for mcHwVersion is deprecated in V-series sensors(VmIPS).
mcHwVersion  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..80))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The manufacturer specified hardware version information.
		Typically indicated major, minor, patch information for version."
	::= { mgmtCardEntry 4 }

mcCurrentSwVersion  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..80))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The manufacturer specified software version information that is currently running.
		Typically indicated major, minor, patch information for version."
	::= { mgmtCardEntry 5 }

mcFutureSwFileName  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..128))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The new software (image) file residing on flash."
	::= { mgmtCardEntry 6 }

mcDateAndTime  OBJECT-TYPE
	SYNTAX 	DateAndTime
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"System date and time set by EMS."
	::= { mgmtCardEntry 7 }

--This group conatins all MIB objects that specify the configuration of the
--Trellix IDS sensor (analysis) card.
--
--The object sensorCardTable within this group suggests that each Trellix IDS chassis
--may contain more than one sensor card.
--
--Support for each logical function is defined in its own table.
--Each table in this group contains entries, one per sensor card, indexed by <slotIndex>

sensorCardGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 10 }

sensorCardTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF SensorCardEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This table contains entries, one per sensor card and indexed by the slotIndex.
		"
	::= { sensorCardGrp 1 }

sensorCardEntry  OBJECT-TYPE
	SYNTAX 	SensorCardEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This MIB object contains all the columnar objects, 
		that describe the contents of each sensor card within the Trellix IDS.
		This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
	INDEX { slotIndex }
	::= { sensorCardTable 1 }

SensorCardEntry ::= SEQUENCE {
	scAction
		TrellixIDSAction,
	scSigUpdateResult
		TrellixIDSActionResult,
	scHwVersion
		DisplayString,
	scCurrentSwVersion
		DisplayString,
	scFutureSwFileName
		DisplayString,
	scCurrentSigVersion
		DisplayString,
	scFutureSigFileName
		DisplayString,
	scMACAddress
		MacAddress,
        scCurrentBotDATVersion
		DisplayString
}

scAction  OBJECT-TYPE
	SYNTAX 	TrellixIDSAction
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Actions on this card. See TrellixIDSAction
		Default: other
		Only reset and sigupdate are supported."
	::= { sensorCardEntry 1 }

scSigUpdateResult  OBJECT-TYPE
	SYNTAX 	TrellixIDSActionResult
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Indicates detail results of scAction object.
		Default: 0
		
		"
	::= { sensorCardEntry 2 }

-- Support for scHwVersion is deprecated in V-series sensors(VmIPS).
scHwVersion  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..80))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The manufacturer specified hardware version information.
		Typically indicated major, minor, patch information for version."
	::= { sensorCardEntry 3 }

scCurrentSwVersion  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..80))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The manufacturer specified software version information that is currently running.
		Typically indicated major, minor, patch information for version."
	::= { sensorCardEntry 4 }

scFutureSwFileName  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..80))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The new software (image) file residing on flash."
	::= { sensorCardEntry 5 }

scCurrentSigVersion  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..80))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The manufacturer specified signature file version information that is currently running.
		Typically indicated major, minor, patch information for version."
	::= { sensorCardEntry 6 }

scFutureSigFileName  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..80))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The new signature file residing on flash."
	::= { sensorCardEntry 7 }

scMACAddress  OBJECT-TYPE
	SYNTAX 	MacAddress
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"ReadOnly parameter, to allow SNMP manager to view the MAC address of this card."
	::= { sensorCardEntry 8 }

scCurrentBotDATVersion  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..80))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The manufacturer specified BotDAT file version information that is currently running."
        ::= { sensorCardEntry 9 }


--
-- IP table
--
ipTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF IpEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This table contains entries that define the IP 
		configuration objects per sensor card."
	::= { sensorCardGrp 6 }

ipEntry  OBJECT-TYPE
	SYNTAX 	IpEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This table entry contains the sensor card specific ( <slotIndex> based) 
		IP configuration objects.
		This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
	INDEX { slotIndex }
	::= { ipTable 1 }

IpEntry ::= SEQUENCE {
	ipFragmentTimer
		INTEGER,
	ipOverlapOption
		INTEGER,
	ipTTLConfigMode
		INTEGER,
	ipTTLThreshold
		INTEGER,
	ipTTLResetValue
		INTEGER,
	ipSmallestFragmentSize
		INTEGER,
	ipSmallFragmentThreshold
		INTEGER,
	ipFragmentReassemblyOption
    		INTEGER,
  	ipv6OverlapOption
    		INTEGER,
  	ipv6SmallestFragmentSize
    		INTEGER,
  	ipv6SmallFragmentThreshold
    		INTEGER

}

ipFragmentTimer  OBJECT-TYPE
	SYNTAX 	INTEGER (3..180)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"IP fragment reassembly timer 
		Default: 30 seconds

		"
	::= { ipEntry 1 }

ipOverlapOption OBJECT-TYPE
	SYNTAX 	INTEGER {
		oldData (1),
		newData (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to oldData(1), ip reassembly module takes old data.
		Otherwise it takes new data.

		Default: oldData (1)"
	::= { ipEntry 2 }

ipTTLConfigMode OBJECT-TYPE
	SYNTAX 	INTEGER {
		noTTLChecking (1),
		checkThreshold (2),
		resetTTL (3)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to noTTLChecking(1), the TTL in the packet is not
		checked. If set to checkThreshold(2), then TTL is checked
		against the value in ipTTLThreshold object. If set to
		resetTTL(3), the TTL value is reset to the value set by
		ipTTLResetValue object.

		Default: noTTLChecking (1)"
	::= { ipEntry 3 }

ipTTLThreshold OBJECT-TYPE
	SYNTAX 	INTEGER (1..255)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Specifies the minimum threshold for the TTL value. The TTL
		in the packet is checked against the value configured here.
		If TTL is less than the value configured here, an alert is
		raised.

		Default: 32"
	::= { ipEntry 4 }

ipTTLResetValue OBJECT-TYPE
	SYNTAX 	INTEGER (1..255)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Specifies the value that TTL should be reset to.

		Default: 32"
	::= { ipEntry 5 }

ipSmallestFragmentSize OBJECT-TYPE
	SYNTAX 	INTEGER (8..1480)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Specifies the smallest fragment size that is acceptable.
		Any fragments smaller than the size specified here (other
		than the last one) will be counted and an alert raised if
		exceeds the threshold configured. The size should be multiple
		of 8.

		Default: 256"
	::= { ipEntry 6 }

ipSmallFragmentThreshold OBJECT-TYPE
	SYNTAX 	INTEGER (100..100000)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Count of acceptable small fragments as specified by
		ipSmallestFragmentSize in 1 minute.

		Default: 10000"
	::= { ipEntry 7 }

ipFragmentReassemblyOption OBJECT-TYPE
	SYNTAX 	INTEGER{
		enable (0),
		disable (1)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Flag to indicate if sensor should reassemble IP Framgments.  Default: enable"
	::= { ipEntry 8 }

ipv6OverlapOption OBJECT-TYPE
	SYNTAX 	INTEGER {
		oldData (1),
		newData (2),
		drop (3)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to oldData(1), ipv6 reassembly module takes old data.
		Otherwise it takes new data.

		Default: oldData (1)"
	::= { ipEntry 9 }

ipv6SmallestFragmentSize OBJECT-TYPE
	SYNTAX 	INTEGER (40..1280)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Specifies the smallest ipv6 fragment size that is acceptable.
		Any fragments smaller than the size specified here (other
		than the last one) will be counted and an alert raised if
		exceeds the threshold configured. The size should be multiple
		of 8.

		Default: 48"
	::= { ipEntry 10 }

ipv6SmallFragmentThreshold OBJECT-TYPE
	SYNTAX 	INTEGER (100..100000)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Count of acceptable small fragments as specified by
		ipSmallestFragmentSize in 1 minute.

		Default: 10000"
	::= { ipEntry 11 }

--
-- TCP Table
--
tcpTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF TcpEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This table contains entries that define the TCP configuration objects per sensor card."
	::= { sensorCardGrp 7 }

tcpEntry  OBJECT-TYPE
	SYNTAX 	TcpEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This table entry contains the sensor card specific ( <slotIndex> based) 
		TCP configuration objects.
		This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
	INDEX { slotIndex }
	::= { tcpTable 1 }

TcpEntry ::= SEQUENCE {
	supportedUDPFlows
		Integer32,
	tcbInactivityTimer
		INTEGER,
	tcpSegmentTimer
		INTEGER,
	tcp2MSLTimer
		INTEGER,
	inactiveFlowsRSTEnabled
		TruthValue,
	dropReTxTCPEnabled
		TruthValue,
	coldStartTime
		INTEGER,
	coldStartDropAction
		INTEGER,	
	normalizationOnOffOption
		INTEGER,
	tcpOverlapOption
		INTEGER,
	sAckPermittedOption
		INTEGER,
	tTCPOptionThreshold
		INTEGER,
	dropOnPAWSFail
		INTEGER,
	timestampEchoMatchFail
		INTEGER,
	dropMD5Option
		INTEGER,
	unsolicitedUDPPacketsTimeout
		INTEGER,
	synProxyEnable
		INTEGER,
	ackScanDiscardTime
		INTEGER,
	halfOpenConnectionResetEnable
		INTEGER,
	outOfContextTcpPktEnable
		INTEGER,
	synCookieConfig  
		INTEGER,
	synCookieInboundThreshold  
		INTEGER,
	synCookieOutboundThreshold  
		INTEGER,
	synCookieMss
		INTEGER,
        sinkHoleTimeToLive
                INTEGER,
        sinkHoleIpAddress
                IpAddress

}

supportedUDPFlows  OBJECT-TYPE
	SYNTAX 	Integer32 (8..1000000)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Number of UDP flows supported. 
		Deafult: 1 million, UDP and TCP combined.

		Default: 100000 for I4000, 25000 for I2600, 5000 for I1200, 10000 for I1400"
	::= { tcpEntry 1 }

tcbInactivityTimer	OBJECT-TYPE 
	SYNTAX 	INTEGER (3..1200)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"TCB inactivity timeout  
		
		Default: 10 minutes"
	::= { tcpEntry 2 }

tcpSegmentTimer  OBJECT-TYPE
	SYNTAX 	INTEGER (10..120)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"TCP segment reassembly timer.
		
		Default: 60 seconds
		"
	::= { tcpEntry 3 }

tcp2MSLTimer  OBJECT-TYPE
	SYNTAX 	INTEGER (3..120)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"TCP 2MSL timer 
		
		Default: 10 seconds"
	::= { tcpEntry 4 }

inactiveFlowsRSTEnabled  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Option to RST incative flows enabled (TRUE) or not (FALSE).

		Default: FALSE"
	::= { tcpEntry 5 }

dropReTxTCPEnabled  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"IntruShield may get TCP segments which have already been processed by it apriori
		(due to the segments being dropped in between it and the destination). 
		By default, forward it without any processing, but provide the user with an option 
		to drop such selectively retransmitted segments.
		
		This object enables the dropping of retransmitted TCP packets.
		
		Default: FALSE"
	::= { tcpEntry 6 }

coldStartTime OBJECT-TYPE
	SYNTAX 	INTEGER (0..10080)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"When sensor powers up, it will treat the packets for flows 
		that did not exist without valid TCB as valid packets. After
		the time configured with this object, packets without valid
		flows are considered invalid packets.

		Default: 60min"
	::= { tcpEntry 7 }

coldStartDropAction OBJECT-TYPE
	SYNTAX 	INTEGER {
		dropFlows (1),
		forwardFlows (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"When this object is set to dropFlows(1), in inline mode
		sensor will drop the packets without valid TCB.

		When this object is set to forwardFlows(2), in inline mode
		sensor will forward the packets until coldStartTime. After
		that it will drop the packets without valid TCB.

		Default: forwardFlows(2)"
	::= { tcpEntry 8 }

normalizationOnOffOption OBJECT-TYPE
	SYNTAX 	INTEGER {
		on (1),
		off (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Enable or Disable normalization

		Default: off(2)"
	::= { tcpEntry 9 }

tcpOverlapOption OBJECT-TYPE
	SYNTAX 	INTEGER {
		oldData (1),
		newData (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If this object is set to oldData(1), tcp reassembly module
		will use the old data. Otherwise it will use the newer data.

		Default: newData(2)"
	::= { tcpEntry 10 }

sAckPermittedOption OBJECT-TYPE
	SYNTAX 	INTEGER {
		on (1),
		off (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to on, removes in SYN and clears in further packets.
		This applies only in inline mode."
	::= { tcpEntry 11 }

tTCPOptionThreshold OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Generate alert if too many. TBD"
	::= { tcpEntry 12 }

dropOnPAWSFail OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to enable, drop if fails PAWS test. If set to disable
		always forward the packet."
	::= { tcpEntry 13 }

timestampEchoMatchFail OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to enable, drop if TS-echo was one not sent earlier.
		If set to disable always forward the packet."
	::= { tcpEntry 14 }

dropMD5Option OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to enable, drop packet if SYN=0 and it contains 
		no MD5 but MD5 was used at setup. If set to disable always 
		forward the packet."
	::= { tcpEntry 15 }

unsolicitedUDPPacketsTimeout OBJECT-TYPE
	SYNTAX 	INTEGER (10..3600)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If a UDP response packet is received without a request 
		packet, the packet will be dropped. This object configures 
		the acceptable request to response time.

		Default: 60"
	::= { tcpEntry 16 }

synProxyEnable OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to enable, sensor will do SYN proxy for every SYN
		request. SYN proxy is done only when TCP SYN flood is 
		detected."
	::= { tcpEntry 17 }

ackScanDiscardTime OBJECT-TYPE
        SYNTAX  INTEGER (0..1440)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The time in which ACK scan messages should be discarded.
		Default 15 minutes"
        ::= { tcpEntry 18 }

halfOpenConnectionResetEnable  OBJECT-TYPE
	SYNTAX 	INTEGER {
		resetDisable (1),
		resetAllUnfinished3WHConns (2),
		resetDosUnfinished3WHConns (3)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Resets either all or only DOS packets whose 3 Way Handshake has not finished. Default: Disable(1). "
	::= { tcpEntry 19 }

outOfContextTcpPktEnable  OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2),
		permit-out-of-order (3),
		deny-no-tcb (4),
		stateless-inspection (5)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Used to en/dis able processing of out of context TCP packets. Enable aka PERMIT, Disable aka DENY, PERMIT_OUT_OF_ORDER(3), DENY-NO-TCB (4) aka PERMIT-ACL-MODE, STATELESS_INSPECTION (5). Default: PERMIT(1)"
	::= { tcpEntry 20 }

synCookieConfig  OBJECT-TYPE
	SYNTAX INTEGER {
		disable (0),
		enable-inbound (1),
		enable-outbound (2),
		enable-in-out (3) 
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		" This object specifies the directions in which to enable syn cookie when there is a
		SYN flood.  This option is valid only for monitoring ports operating in inline mode.
		Default: 0"
	::= { tcpEntry 21 }
    
synCookieInboundThreshold  OBJECT-TYPE
	SYNTAX INTEGER (0..420000)
 	MAX-ACCESS  read-write
	STATUS   current
	DESCRIPTION
		"This object specifies the threshold value for the number of incomplete SYNs from outside 
         network beyond which SYN cookie mechanism has to be enabled.
		Default: 4096" 
	::= { tcpEntry 22 }

synCookieOutboundThreshold  OBJECT-TYPE
	SYNTAX INTEGER (0..420000)
 	MAX-ACCESS  read-write
	STATUS   current
	DESCRIPTION
		"This object specifies the threshold value for the number of incomplete SYNs from inside
         network beyond which SYN cookie mechanism has to be enabled.
		Default: 4096" 
	::= { tcpEntry 23 }

synCookieMss OBJECT-TYPE
	SYNTAX INTEGER (536..1460)
 	MAX-ACCESS  read-write
	STATUS   current
	DESCRIPTION
		"This object specifies the maximum segment size to be sent in SYN Ack, with SYN cookie mechanism enabled.
		Default: 536" 
	::= { tcpEntry 24 }

sinkHoleTimeToLive OBJECT-TYPE
        SYNTAX INTEGER (6..18)
        MAX-ACCESS  read-write
        STATUS   current
        DESCRIPTION
                "This object specifies the TTL duration for sinkhole. TTL duration can range from 6 hours to 18 hours,
                Default: 12 hours"
        ::= { tcpEntry 25 }

sinkHoleIpAddress OBJECT-TYPE
        SYNTAX  IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure IPv4 address of sinkhole. It can be any valid ip address apart from 
                broadcast and multicast address.
                Default: 127.0.0.1"
        ::= { tcpEntry 26 }

--
-- TCP/UDP session reset and log table
--
sessionTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF SessionEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Session table is used by user to configure TCP and UDP flows
		in the sensor."
	::= { sensorCardGrp 8 }

sessionEntry  OBJECT-TYPE
	SYNTAX 	SessionEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Indexed with 5-tuple flow parameters and VIDS identifier.
		This table is used only to send sets to the sensor. Doing
		GET on this table will not return any information."
	INDEX {sessionSrcIpAddress, sessionDestIpAddress,
		sessionSrcPortNo, sessionDestPortNo, sessionProtocol,
		sessionVIDSIdentifier }
	::= { sessionTable 1 }

SessionEntry ::= SEQUENCE {
	sessionSrcIpAddress
		IpAddress,
	sessionDestIpAddress
		IpAddress,
	sessionSrcPortNo
		INTEGER,
	sessionDestPortNo
		INTEGER,
	sessionProtocol
		INTEGER,
	sessionVIDSIdentifier
		INTEGER,
	sessionConfigAction
		INTEGER,
	sessionLogTime
		INTEGER,
	sessionIntfPortNo
		TrellixPortLinearIndex
}

sessionSrcIpAddress OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Source ip address."
	::= { sessionEntry 1 }

sessionDestIpAddress OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Destination ip address."
	::= { sessionEntry 2 }

sessionSrcPortNo OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Source port number."
	::= { sessionEntry 3 }

sessionDestPortNo OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Destination port number."
	::= { sessionEntry 4 }

sessionProtocol OBJECT-TYPE
	SYNTAX 	INTEGER {
		tcp (1),
		udp (2)
	}
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Protocol type."
	::= { sessionEntry 5 }

sessionVIDSIdentifier OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"VIDS identifier that owns this flow. If VIDS is not 
		enabled, this oject will be ignored."
	::= { sessionEntry 6 }

sessionConfigAction OBJECT-TYPE
	SYNTAX 	INTEGER {
		resetSession (1),
		logSession (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Setting this object to resetSession(1) causes the flow
		to be reset.

		Setting this object to logSession(2) causes the flow to be
		logged for the time specified with sessionLogTime object."
	::= { sessionEntry 7 }

sessionLogTime OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The time for which the packet needs to be logged."
	::= { sessionEntry 8 }

sessionIntfPortNo OBJECT-TYPE
	SYNTAX 	TrellixPortLinearIndex
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The sensor linear interface port index on which the attack has been detected. 
		This is mandatory when the sessionConfigAction is resetSession. "
	::= { sessionEntry 9 }


--
-- IPV6 TCP/UDP session reset and log table 
--

sessionV6Table  OBJECT-TYPE
	SYNTAX SEQUENCE OF SessionV6Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Session table v6 is used by user to configure TCP and UDP flows
		over Ipv6 in the sensor."
	::= { sensorCardGrp 9 }

sessionV6Entry  OBJECT-TYPE
	SYNTAX 	SessionV6Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Indexed with 5-tuple flow parameters and VIDS identifier.
		This table is used only to send sets to the sensor. Doing
		GET on this table will not return any information."
	INDEX {sessionSrcIpv6Address, sessionDestIpv6Address,
		sessionv6SrcPortNo, sessionv6DestPortNo, sessionv6Protocol,
		sessionv6VIDSIdentifier }
	::= { sessionV6Table 1 }

SessionV6Entry ::= SEQUENCE {
	sessionSrcIpv6Address
		Ipv6Address,
	sessionDestIpv6Address
		Ipv6Address,
	sessionv6SrcPortNo
		INTEGER,
	sessionv6DestPortNo
		INTEGER,
	sessionv6Protocol
		INTEGER,
	sessionv6VIDSIdentifier
		INTEGER,
	sessionv6ConfigAction
		INTEGER,
	sessionv6LogTime
		INTEGER,
	sessionv6IntfPortNo
		TrellixPortLinearIndex
}

sessionSrcIpv6Address OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Source ipv6 address."
	::= { sessionV6Entry 1 }

sessionDestIpv6Address OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Destination ipv6 address."
	::= { sessionV6Entry 2 }

sessionv6SrcPortNo OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Source port number."
	::= { sessionV6Entry 3 }

sessionv6DestPortNo OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Destination port number."
	::= { sessionV6Entry 4 }

sessionv6Protocol OBJECT-TYPE
	SYNTAX 	INTEGER {
		tcp (1),
		udp (2)
	}
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Protocol type."
	::= { sessionV6Entry 5 }

sessionv6VIDSIdentifier OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"VIDS identifier that owns this flow. If VIDS is not 
		enabled, this oject will be ignored."
	::= { sessionV6Entry 6 }

sessionv6ConfigAction OBJECT-TYPE
	SYNTAX 	INTEGER {
		resetSession (1),
		logSession (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Setting this object to resetSession(1) causes the flow
		to be reset.

		Setting this object to logSession(2) causes the flow to be
		logged for the time specified with sessionLogTime object."
	::= { sessionV6Entry 7 }

sessionv6LogTime OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The time for which the packet needs to be logged."
	::= { sessionV6Entry 8 }

sessionv6IntfPortNo OBJECT-TYPE
	SYNTAX 	TrellixPortLinearIndex
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The sensor linear interface port index on which  the attack has been detected. 
		This is mandatory when the sessionConfigAction is resetSession "
	::= { sessionV6Entry 9 }

pluggableModuleState  OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Indicates the state of the pluggable modules in the system. Applicable
    for Rubicon models only. 32 bit  starting from LSB, 4 bits for each 
    slot starting from 2, will contain the moduleSysType enum
    => 0000 0000 0000 0000 0000 <slot4> <slot3> 0000."
	::= { sensorCardGrp 10 }

-- This group conatins all MIB objects that specify the configuration of 
-- the IntruShield interface port.
--
-- The object intfPortTable within this group suggests that the MIB is 
-- designed to support sensor cards that can contain more than one interface 
-- port.
--

interfacePortGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 11 }

intfPortTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF IntfPortEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table containing entries for each interface port (indexed via intfPortIndex) 
		on each sensor card (indexed via appropriate slotIndex).
		
		This table contains Trellix specific configuration objects.
		Tables that contain MIB objects borrowed from MIB-II are in the 
		TRELLIX-SENSOR-PERF-MIB."
	::= { interfacePortGrp 1 }

intfPortEntry  OBJECT-TYPE
	SYNTAX 	IntfPortEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This MIB object contains all the columnar objects, 
		that describe the contents of each interface port on each IntruShield sensor card.
		Indexed by slotIndex/intfPortIndex"
	INDEX { slotIndex, 
		intfPortIndex }
	::= { intfPortTable 1 }

IntfPortEntry ::= SEQUENCE {
	intfPortIfDescr
		DisplayString,
	intfPortIfType
		TrellixIDSPortType,
	intfPortIfAdminStatus
		INTEGER,
	intfPortIfOperStatus
		INTEGER,
	intfPortOperatingMode
		TrellixIDSOperatingMode,
	intfPortEnableFullDuplex
		TruthValue,
	intfPortFullDuplexPeer
		Integer32,
	intfPortSpeed
		INTEGER,
	intfPortSpeedConfig
		TrellixPortSpeed, -- was TrellixFEType, now deprecated
	intfPortEnableInternalTap
		TruthValue,
	intfPortInOutType
		INTEGER,
	intfGEPortSpeedConfig
		INTEGER,
	intfFailOpenSwitchStatus
		INTEGER,
	intfFailOpenPortStatus
		INTEGER,
	intfPortEnableAntiSpoofing
		INTEGER,
	intfPortHostQRActionStatus
		INTEGER,
	intfPortMpeQRActionStatus
		INTEGER,
	intfPortAllowlistACLLookupStatus
		INTEGER,
        intfPortPeerDeviceAdvtStatus
                INTEGER,
        intfPortIsMcafeeConnector
                TruthValue,
        intfPortAllowAnyConnector
                TruthValue,
        intfPortCageType
                INTEGER,
        intfPortGetMediaType
                INTEGER,
        intfPortSetMediaType
                INTEGER,
        intfPortAdditionalInfo
                DisplayString,
	intfPortMonPortIpAddress
		IpAddress,
	intfPortMonPortNetMask
		IpAddress,
	intfPortGatewayIpAddress
		IpAddress,
	intfPortNbadConfigStatus
		TruthValue,
	intfPortVlanId
		Integer32,
	intfPortAppIdStatsConfigStatus
		TruthValue,
  	intfPortConnectorType
    		INTEGER,
	intfPortLinearIndex
		TrellixPortLinearIndex,
	intfPortFecConfig
		INTEGER,
	intfPortTranceiverSerialNumber
		DisplayString
}

intfPortIfDescr  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..255))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"A textual string containing information about the interface.  
		Returns the string that is printed on the box."
	::= { intfPortEntry 1 }

intfPortIfType  OBJECT-TYPE
	SYNTAX 	TrellixIDSPortType
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The type of interface, distinguished according to the 
		physical/link protocol(s) immediately 'below' the network 
		layer in the protocol stack.
		
		For brevity, Trellix options are as specified by the TC, 
		TrellixIDSPortType.
		
		However, the SNMP MIB-II - Interfaces MIB specifies many more 
		valid options. See comments section for details.
		"
	::= { intfPortEntry 2 }

intfPortIfAdminStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		up (1),
		down (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The desired state of the interface.  
		The testing(3) state indicates that no operational packets 
		can be passed.

		Default: down"
	::= { intfPortEntry 3 }

intfPortIfOperStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		up (1),
		down (2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The current operational state of the interface.
		The testing(3) state indicates that no operational packets 
		can be passed.
		
		Default: down"
	::= { intfPortEntry 4 }

intfPortOperatingMode  OBJECT-TYPE
	SYNTAX 	TrellixIDSOperatingMode
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"ReadWrite parameter specifies the operating mode for the 
                Trellix IDS sensor to be used. Different modes supported are
                inline-fo-passive(1), non-inline or tap(2), span(3) and
                inlne-fc(4), inline-fo-active kit(5 - available on M-series only).
		
		Default: non-inline"
	::= { intfPortEntry 5 }

-- Support for intfPortEnableFullDuplex is deprecated in V-series sensors(VmIPS).
intfPortEnableFullDuplex  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"True: Sets interface port to work as a full-duplex one. 
		Otherwise as half-duplex.
		
		Default: True"
	::= { intfPortEntry 6 }

-- Support for intfPortFullDuplexPeer is deprecated in V-series sensors(VmIPS).
intfPortFullDuplexPeer  OBJECT-TYPE
	SYNTAX 	Integer32 (1..32)
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This MIB object returns the intfPortIndex value of the 
		interface port that is a peer. Used only when operating mode
		is inline(1) or monitor-dual-intf(2)."
	::= { intfPortEntry 7 }

-- Support for intfPortSpeed is deprecated in V-series sensors(VmIPS).
intfPortSpeed  OBJECT-TYPE
	SYNTAX 	INTEGER {
		other (0),
		ten-Mbps (1),
		hundred-Mbps (2),
		one-Gbps(3), -- renamed from gig-Mbps
		ten-Gbps(4),  -- support in M-series and R-series only
		forty-Gbps(5)  -- support in R-series only
	}

	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Get current speed/negotiation on the interface."
	::= { intfPortEntry 8 }

-- Support for intfPortSpeedConfig is deprecated in V-series sensors(VmIPS).
intfPortSpeedConfig  OBJECT-TYPE
	SYNTAX 	TrellixPortSpeed -- was TrellixFEType, now deprecated
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Set desired speed/negotiation on the interface.
                 Default values are as follows: 
	I-Series -
		fixed-hundred-Mbps (infinity/hichborn/2x00(1a-3b)
		auto-gig-Mbps on 3000/4010/4000/2x00(4a,4b)
	M-Series -
		auto-ten-gig-Mbps on palomar/pyramid(1a-4b),auto-gig-Mbps(5a-8b)
		Default: see above"
	::= { intfPortEntry 9 }


intfPortEnableInternalTap  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Set to TRUE to enable feature. Applies to Fast Ethernet (FE) 
		ports only (see TrellixIDSPortType).
		For non FE ports, set to 'FALSE' .
		Setting this to 'TRUE' requires that 
		<intfPortCurrentOperatingMode> is already set to 
		'monitor-dual-intf'
		Default: True"

	::= { intfPortEntry 10 }

intfPortInOutType  OBJECT-TYPE
	SYNTAX 	INTEGER {
		inside (1),
		outside (2),
		not-specified (3)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This MIB object reflects the Input or Output labeling 
		of this interface port. Used only when operating mode
		is inline(1) or monitor-dual-intf(2). 

		Default: not-specified(3)"
	::= { intfPortEntry 11 }

-- Definition of intfGEPortSpeedConfig OID stays in the MIB
-- Support for intfGEPortSpeedConfig is deprecated in sensors using new MIB.
-- Support for intfGEPortSpeedConfig is deprecated in M-series sensors and V-series sensors(VmIPS).
intfGEPortSpeedConfig  OBJECT-TYPE
	SYNTAX 	TrellixGEType
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Only applicable to gigabit-ethernet ports, to specify 
		whether auto or 1 Gbps
		See TrellixGEType
		
		Default: 'auto-negotiate'"
	::= { intfPortEntry 12 }

-- Support for intfFailOpenSwitchStatus is availble in V-series sensors(VmIPS)
-- only when port operting mode is inline-fo-active
intfFailOpenSwitchStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		not-applicable(1),
		present(2),
		not-present(3)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Returns the status of the external optical bypass switch
		status. For FE ports, this object will return 
		not-applicable(1). For GE ports, if external optical bypass 
		switch is connected to sensor ports, this will return 
		present(2). Otherwise, it will return not-present(3)."
	::= { intfPortEntry 13 }

-- Support for intfFailOpenPortStatus is availble in V-series sensors(VmIPS)
-- only when port operting mode is inline-fo-active
intfFailOpenPortStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		not-applicable(1),
		inline-fail-open(2),
		bypass(3),
                tap (4),
                absent (5),
                unknown (6),
                layer2-bypass (7)
               
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Returns the packet forwarding status of the sensor ports connected to the optical bypass switch.
		If status is inline-fail-open(2), sensor is doing the
		forwarding. If status is bypass(3), the bypass switch is
		doing the forwarding and sensor will not process any
                traffic in this mode. Tap(4), absent(5) , unknown (6) and layer2-bypass(7)
                are available only in M-series for non RJ45(captive) ports
                when connected to active FO kit and sensor operating mode
                is inline-fail-open-active-kit.
                tap - operational status(up), kit(present), heart-beat(tap)
                absent - operational status(up), kit(absent), hear-beat(none)
                unknown - operational status(down), kit(absent), heart-beat(not available)."
	::= { intfPortEntry 14 }

intfPortEnableAntiSpoofing  OBJECT-TYPE
	SYNTAX 	INTEGER {
		disable-bothsides-spoof-detect (1),
		enable-inside-spoof-detect (2),
		enable-outside-spoof-detect (3),
		enable-bothsides-spoof-detect (4)
	}
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "spoofed packet detect rcvd on the both sides .

                Default: 'disable-bothsides-spoof-detect' (0) "
        ::= { intfPortEntry 15 }

-- unallocated   ::= { intfPortEntry 16 }
-- unallocated   ::= { intfPortEntry 17 }

intfPortHostQRActionStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		disabled(0),
		quarantine(1),
		remediate(2)
	}
	MAX-ACCESS  read-write
	STATUS	obsolete
	DESCRIPTION 
		"This object depicts the sensor level host quarantine and remediation action status 
		 for the specific interface port. The value 'quarantine' indicates just quarantine the host and
		 the value 'remediate' indicates both quarantining and remediating the host.		 
		Default: disabled"
	::= { intfPortEntry 18 }


intfPortMpeQRActionStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		disabled(0),
		mpeNotify(1),
		mpeQuarantine(2),
		mpeRemediate(3)
	}
	MAX-ACCESS  read-write
	STATUS	obsolete
	DESCRIPTION 
		"This object depicts the MPE respone based host quarantine and remediation action status for the 
		 specific interface port. The value 'mpeNotify' indicates just informing the MPE server
		 about the problem host; the value 'mpeQuarantine' indicates first informing the MPE server
		 about the problem host and then quarantine the host based on the response from the MPE-server
		 and the MPE based Quarantine and Remediation scope mib object value; and the value 'mpeRemediate' 
		 indicates first informing the MPE server about the problem host and then remediating the host 
		 based on the response from the MPE-server and the MPE based Quarantine and Remediation scope
		 mib object value.
		Default: disabled"
	::= { intfPortEntry 19 }

intfPortAllowlistACLLookupStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		disabled(0),
		enabled(1)
	}
	MAX-ACCESS  read-write
	STATUS	obsolete
	DESCRIPTION 
		"This object indicates the status of allowlist ACL lookup for this interface port.
		Default: disabled"
	::= { intfPortEntry 20 }

-- intfPortPeerDeviceAdvtStatus support in M-series sensor only
intfPortPeerDeviceAdvtStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		other (0)            -- need to provide enum list
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Applicable if sensor port is set to auto-negotiate, else other(0). Specifies the advertised speed-duplex of the peer appliance port connected to this sensor port."
	::= { intfPortEntry 21 }

-- intfPortIsMcafeeConnector support in M-series sensor only
intfPortIsMcafeeConnector  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"True: connector is not inserted. 
		 True: connector is inserted in port and McAfee certified. 
                 False: connector is inserted and not McAfee certified.  "
	::= { intfPortEntry 22 }

-- intfPortAllowAnyConnector support in M-series sensor only
intfPortAllowAnyConnector  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"True: Permit usage of any connector for port. 
                 False: Restrict usage to McAfee certified connector only. 
		Default: False"
	::= { intfPortEntry 23 }

-- intfPortCageType support in M-series and R-series sensor only
intfPortCageType  OBJECT-TYPE
	SYNTAX 	INTEGER {
		other (0),
		rJ-45 (1),
		rJ-11 (2),
		gBIC (3),
		sFP (4),
		xFP (5),
    sFP-plus (6), -- support in R-series only
    qSFP (7), -- support in R-series only
    rJ-45-plus (8), -- support in R-series only
    sFP-plus-BPFO (9) -- support in R-series only
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Physical connector cage type on sensor chassis panel."
	::= { intfPortEntry 24 }

-- intfPortGetMediaType support in M-series sensor only
intfPortGetMediaType OBJECT-TYPE
	SYNTAX 	INTEGER {
		none (0),
		optical (1),
		electrical (2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Gets the media of the connector present in the port cage. None (0) if cage is empty."
	::= { intfPortEntry 25 }

-- intfPortSetMediaType support in M-series sensor only
intfPortSetMediaType OBJECT-TYPE
	SYNTAX 	INTEGER {
		optical(1),
		electrical (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Sets the media of the connector the user desired for the port.
		Default: optical"
	::= { intfPortEntry 26 }

intfPortAdditionalInfo  OBJECT-TYPE
	SYNTAX 	DisplayString (SIZE(0..255))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"A textual string containing information about the interface.  
		Typically returns connector specific information.
		For V-series sensors(vmips) this object will return monitoring ports label."
	::= { intfPortEntry 27 }

intfPortMonPortIpAddress OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to configure / retrieve the IPv4 address of the monitoring port.
		 Default: 0.0.0.0"
	::= { intfPortEntry 28 }

intfPortMonPortNetMask OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to configure / retrieve netmask for the IPv4 address of the monitoring port.
		 Default: 0.0.0.0"
	::= { intfPortEntry 29 }

intfPortGatewayIpAddress OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to configure / retrieve the IPv4 address of the gateway.
		 Default: 0.0.0.0"
	::= { intfPortEntry 30 }

intfPortNbadConfigStatus OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object value if set to TRUE indicates that flow record generation
		 to be sent to the NBAD server, is enabled over this monitoring port.
		Default: False"
	::= { intfPortEntry 31 }

intfPortVlanId  OBJECT-TYPE
	SYNTAX 	Integer32 (0..2164326399)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This MIB object indicates the Vlan ID of the VLAN to which the monitoring 
		 port is connected."
	::= { intfPortEntry 32 }

intfPortAppIdStatsConfigStatus  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object value if set to TRUE indicates that the appId stats collection is enabled
         over this monitoring port.
		Default: True"
	::= { intfPortEntry 33 }

-- intfPortConnectorType support in R-series sensor only
intfPortConnectorType  OBJECT-TYPE
	SYNTAX 	INTEGER {
		other (0),
		qSFP (1),
		sFP-plus (2),
		sFP-fiber (3),
		sFP-copper (4)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Physical connector type plugged into the port cage."
	::= { intfPortEntry 34 }

intfPortLinearIndex   OBJECT-TYPE
	SYNTAX 	TrellixPortLinearIndex
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This MIB object indicates the Linear Index of the monitoring port. This index is 
		generated by the sensor appliance using the pair of slot index and the port index values.
		The other MIB tables would directly use this linear index, whereever applicable."
	::= { intfPortEntry 35 }

intfPortFecConfig  OBJECT-TYPE
        SYNTAX  INTEGER
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure FEC"
        ::= { intfPortEntry 36 }

intfPortTranceiverSerialNumber  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "A textual string containing information about the interface.
                Typically returns transceiver's serial number."
        ::= { intfPortEntry 37 }

-- Support for intfPortGBICHotSwapTime is deprecated in V-series sensors(VmIPS).
intfPortGBICHotSwapTime  OBJECT-TYPE
	SYNTAX 	DateAndTime
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Indicates time when the front end GBIC for any port was hot swapped last."
	::= { interfacePortGrp 2 }

--This group contains all MIB objects that specify the configuration of the IntruShield 
--response port.
--
--The object respPortTable within this group suggests that the MIB is designed to support
--response cards that can contain more than one response port.

responsePortGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 12 }

respPortTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF RespPortEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table containing entries for each response port (indexed via respPortIndex) 
		on each sensor card (indexed via valid slotIndex).
		
		This table contains Trellix specific MIB objects.
		"
	::= { responsePortGrp 1 }

respPortEntry  OBJECT-TYPE
	SYNTAX 	RespPortEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This MIB object contains all the columnar objects, 
		that describe the contents of each response port within the Trellix IDS sensor card.
		Indexed by slotIndex/respPortIndex"
	INDEX { slotIndex, 
		respPortIndex }
	::= { respPortTable 1 }

RespPortEntry ::= SEQUENCE {
	respPortDescr
		DisplayString,
	respPortType
		TrellixIDSPortType,
	respPortAdminStatus
		INTEGER,
	respPortOperStatus
		INTEGER,
	respPortEnableFullDuplex
		TruthValue,
	respPortSpeed
		TrellixPortSpeed, -- was TrellixFEType,
	respPortPktDestination
		INTEGER,
	respPortMacAddress
		MacAddress,
	respCUGEPortSpeed
		TrellixCUGEType,
	respAdditionalInfo
		DisplayString
}

respPortDescr  OBJECT-TYPE
	SYNTAX 	DisplayString
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"A textual string containing information about the interface.  
		Returns the string that is printed on the box."
	::= { respPortEntry 1 }

respPortType  OBJECT-TYPE
	SYNTAX 	TrellixIDSPortType
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The type of interface, distinguished according to the 
		physical/link protocol(s) immediately 'below' the network 
		layer in the protocol stack.
		
		See  TrellixIDSPortType.
		"
	::= { respPortEntry 2 }

respPortAdminStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		up (1),
		down (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The desired state of the interface.  
		
		Default: Up"
	::= { respPortEntry 3 }

respPortOperStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		up (1),
		down (2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The current operational state of the interface.
		The testing(3) state indicates that no operational packets 
                can be passed."
	::= { respPortEntry 4 }

-- Support for respPortEnableFullDuplex is deprecated in V-series sensors(VmIPS).
respPortEnableFullDuplex  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"True: Sets response port to work as a full-duplex one. 
		otherwise as half-duplex.
		If True, respPortFullDuplexPeer must be specified.
		
		Default: False
		"
	::= { respPortEntry 5 }

-- Support for respPortSpeed is deprecated in V-series sensors(VmIPS).
respPortSpeed  OBJECT-TYPE
	SYNTAX 	TrellixPortSpeed
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"See TrellixPortSpeed

		Default: fixed-hundred-Mbps (2)"
	::= { respPortEntry 6 }

respPortPktDestination OBJECT-TYPE
	SYNTAX 	INTEGER {
		switch (1),
		router (2)
	}

	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used when response ports are chosen for
		sending response packets. When router mode is chosen,
		packets will be sent to router with destination MAC as
		defined in intfRespMacAddress.

		Default value is switch (1)."
	::= { respPortEntry 7 }

respPortMacAddress OBJECT-TYPE
	SYNTAX 	MacAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Specifies the macaddress of the router to which the response
		packets have to be sent to."
	::= { respPortEntry 8 }

-- Support for  respCUGEPortSpeed is deprecated in V-series sensors(VmIPS).
respCUGEPortSpeed  OBJECT-TYPE
	SYNTAX 	TrellixCUGEType
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION
		"Only applicable to copper-gigabit-ethernet ports, to specify whether
		10mbps or 100mbps or 1-gbps or auto-neg. See TrellixCUGEType

		Default: auto-negotiate"
	::= { respPortEntry 9 }


respAdditionalInfo  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "A textual string containing additional information about the response interface.
                This mib object will be available only on V-series sensors."
        ::= { respPortEntry 11 }


-- respPortPktDestination OBJECT-TYPE
--
-- Interface Response Table
--
intfRespTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF IntfRespEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table containing entries for each interface port. The
		table describes how responses have to be sent in monitoring
		mode."
	::= { responsePortGrp 2 }

intfRespEntry  OBJECT-TYPE
	SYNTAX 	IntfRespEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Indexed by slotIndex/intfPortIndex"
	INDEX { slotIndex, intfPortIndex }
	::= { intfRespTable 1 }

IntfRespEntry ::= SEQUENCE {
	intfRespType
		INTEGER,
	intfRespPortNo
		INTEGER
}

intfRespType OBJECT-TYPE
	SYNTAX 	INTEGER {
		responsePort (1),
		inline (2)
	}

	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Setting this object to responsePort (2) causes responses
		to be sent via the response port. The response port no that
		needs to be used is specified with intfRespPortNo object.

		Setting this object to inline (3) causes responses to be
		sent inline. Note that in monitoring mode, responses can
		only be sent inline when the monitoring port is in
		half-duplex mode.

		Default action will be responsePort (1)."
	::= { intfRespEntry 1 }

intfRespPortNo OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Specifies the response port number that needs to be used
		for this monitoring port. The response ports are configured
		by respPortTable."
	::= { intfRespEntry 2 }


--
-- DOS Configuration Group
--
dosConfigGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 14 }

dosLearningModeAction OBJECT-TYPE
	SYNTAX 	INTEGER {
		forceDetection (1),
		learning (2),
		reloadProfile (3)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object can be used to switch the mode to DOS learning or
		force detection mode . 

		The saved profile can be reloaded by setting the object to
		reloadProfile(3).

		When set to forceDetection (1), user must be warned as follows,
                Warning: You are about to force the sensor into Detection Mode 
                         before the required 48-hour learning period. 
                         The traffic profile learned by the sensor may not be 
                         adequate for DOS attack detection and prevention. 
                         It is desirable to place the sensor in learning mode 
                         while receiving normal traffic for at least 48 hours.  
		"
	::= {dosConfigGrp  1 }

--
-- DOS Profile Table
-- 
-- This table will only support GET requests
--
dosProfileTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF DosProfileEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table defines profile data for each DOS VPT entry."
	::= { dosConfigGrp 2 }

dosProfileEntry  OBJECT-TYPE
	SYNTAX 	DosProfileEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Indexed by VIDS ID and Profile ID."
	INDEX { dosProfileVidsId, dosProfileId }
	::= { dosProfileTable 1 }

DosProfileEntry ::= SEQUENCE {
	dosProfileVidsId
		Unsigned32,
	dosProfileId
		Unsigned32,
	dosProfileStatus
		INTEGER,
	dosProfileLearningTime
		Unsigned32
}

dosProfileVidsId OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"The virtual admin domain identifier."
	::= { dosProfileEntry 1 }

dosProfileId OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"The identifier of the profile."
	::= { dosProfileEntry 2 }

dosProfileStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		learning(1),
		detection(2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The status of the profile entry."
	::= { dosProfileEntry 3 }

dosProfileLearningTime OBJECT-TYPE
	SYNTAX Unsigned32
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The time (in hundredths of a second) since learning was started for the profile."
	::= { dosProfileEntry 4 }


--
-- DOS Profile Bulk Table
-- 
dosProfileBulkTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF DosProfileBulkEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table defines profile data for each DOS VPT entry. This table
		is primarily used to get the GETNEXT and GETBULK."
	::= { dosConfigGrp 3 }

dosProfileBulkEntry  OBJECT-TYPE
	SYNTAX 	DosProfileBulkEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Indexed by profile index."
	INDEX { dosProfileBulkIndex }
	::= { dosProfileBulkTable 1 }

DosProfileBulkEntry ::= SEQUENCE {
	dosProfileBulkIndex
		INTEGER,
	dosProfileBulkVidsId
		Unsigned32,
	dosProfileBulkId
		Unsigned32,
	dosProfileBulkStatus
		INTEGER,
	dosProfileBulkLearningTime
		Unsigned32
}

dosProfileBulkIndex OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"The index of the profile table."
	::= { dosProfileBulkEntry 1 }

dosProfileBulkVidsId OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The virtual admin domain identifier."
	::= { dosProfileBulkEntry 2 }

dosProfileBulkId OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The identifier of the profile."
	::= { dosProfileBulkEntry 3 }

dosProfileBulkStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		learning(1),
		detection(2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The status of the profile entry."
	::= { dosProfileBulkEntry 4 }

dosProfileBulkLearningTime OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"The time (in hundredths of a second) since learning was started for the profile."
	::= { dosProfileBulkEntry 5 }


--
-- DOS ShortTerm LongTerm Profile Table
-- This table will onl support GET requests
-- 
dosProfileShortAndLongTermTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF DosProfileShortAndLongTermEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table defines short term and long term profile data per DOS measure per VPT. Each VPT is indexed by the global VIDSID, global NIId."
	::= { dosConfigGrp 4 }

dosProfileShortAndLongTermEntry  OBJECT-TYPE
	SYNTAX 	DosProfileShortAndLongTermEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Indexed by global VIDSIndex, global NIIndex & measureId."
	INDEX { dosProfileShortAndLongTermVIDSIndex, dosProfileShortAndLongTermNIIndex, dosProfileShortAndLongTermMeasureIndex }
	::= { dosProfileShortAndLongTermTable 1 }

DosProfileShortAndLongTermEntry ::= SEQUENCE {
	dosProfileShortAndLongTermVIDSIndex
		Unsigned32,
	dosProfileShortAndLongTermNIIndex
		Unsigned32,
	dosProfileShortAndLongTermMeasureIndex
		INTEGER,
	dosProfileShortAndLongTermBinCount
		INTEGER,
	dosProfileShortTermContent
		OCTET STRING,
	dosProfileLongTermContent
		OCTET STRING
}

dosProfileShortAndLongTermVIDSIndex OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"The VIDS id index."
	::= { dosProfileShortAndLongTermEntry 1 }

dosProfileShortAndLongTermNIIndex OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"The NI id index."
	::= { dosProfileShortAndLongTermEntry 2 }

dosProfileShortAndLongTermMeasureIndex OBJECT-TYPE
	SYNTAX 	INTEGER (1..10)
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"The measure id index."
	::= { dosProfileShortAndLongTermEntry 3 }

dosProfileShortAndLongTermBinCount OBJECT-TYPE
	SYNTAX 	INTEGER (1..32)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The count indicates the number of short or long term values to be interpreted in their respective content objects. Max value is 32. If the value is set to 10, then only the first 80 bytes in each of the strings have valid data. Note: that 256 octet strings can accomodate a max of 32 values (3 octects each) "
        ::= { dosProfileShortAndLongTermEntry 4 }

dosProfileShortTermContent  OBJECT-TYPE
	SYNTAX 	OCTET STRING (SIZE(256))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This specifies the short term profile data. 
		Default: All 256 octets filled with '0'."
	::= { dosProfileShortAndLongTermEntry 5 }

dosProfileLongTermContent  OBJECT-TYPE
	SYNTAX 	OCTET STRING (SIZE(256))
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This specifies the long term profile data. 
		Default: All 256 octets filled with '0'."
	::= { dosProfileShortAndLongTermEntry 6 }

enableDosPktLogging OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object can be used to turn on/off the logging od DOS packets. Default: disable (2)."
	::= { dosConfigGrp  6 }

--
-- Timed Drop DOS Pkt Table
-- This table does not support GET NEXT requests
--
timedDosPktDropTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF TimedDosPktDropEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "Table defines action and duration to enable/disable/extend the duration for which DOS pkts are to be drpped. Also provides the absolute time remaining till when it the sensor will drop these packets. "
        ::= { dosConfigGrp 7 }

timedDosPktDropEntry  OBJECT-TYPE
        SYNTAX  TimedDosPktDropEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "Indexed by VIDS ID NI ID and MeasureId."
        INDEX { timedDosPktDropVidsIdIndex, timedDosPktDropNiIdIndex, timedDosPktDropMsrIdIndex }
        ::= { timedDosPktDropTable 1 }

TimedDosPktDropEntry ::= SEQUENCE {
        timedDosPktDropVidsIdIndex
                Unsigned32,
        timedDosPktDropNiIdIndex
                Unsigned32,
        timedDosPktDropMsrIdIndex
                INTEGER,
        timedDosPktDropAction
                INTEGER,
        timedDosPktDropDuration
                Unsigned32,
        timedDosPktDropEndTime
                Unsigned32
}

timedDosPktDropVidsIdIndex OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "The Vids identifier."
        ::= { timedDosPktDropEntry 1 }

timedDosPktDropNiIdIndex OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "The NI identifier."
        ::= { timedDosPktDropEntry 2 }

timedDosPktDropMsrIdIndex OBJECT-TYPE
        SYNTAX  INTEGER
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "The MeasureId identifier."
        ::= { timedDosPktDropEntry 3 }

timedDosPktDropAction OBJECT-TYPE
        SYNTAX  INTEGER {
                enable(1),
                disable(2),
                extend(3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The action tells the bulkTimedDosPktDropTable to add(enable the duration for), delete(disable), modify(extend the duration for) an entry."
 
        ::= { timedDosPktDropEntry 4 }

timedDosPktDropDuration OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The duration for which the DOS pkt drop has been enabled or extended."
        ::= { timedDosPktDropEntry 5 }

--
timedDosPktDropEndTime OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The absolute end time when the duration for intended action expires."
        ::= { timedDosPktDropEntry 6 }

--
-- Bulk Timed Drop DOS Pkt Table
--
bulkTimedDosPktDropTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF BulkTimedDosPktDropEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "Table lists entries indexed by the bulkTimedDosPktDropIndex, each returns the corresponding VidsId, NiId, MeasureId and the EndTime value."
        ::= { dosConfigGrp 8 }

bulkTimedDosPktDropEntry  OBJECT-TYPE
        SYNTAX  BulkTimedDosPktDropEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "Indexed by bulk index."
        INDEX { bulkTimedDosPktDropIndex }
        ::= { bulkTimedDosPktDropTable 1 }

BulkTimedDosPktDropEntry ::= SEQUENCE {
        bulkTimedDosPktDropIndex
                INTEGER,
        bulkTimedDosPktDropVidsId
                Unsigned32,
        bulkTimedDosPktDropNiId
                Unsigned32,
        bulkTimedDosPktDropMsrId
                INTEGER,
        bulkTimedDosPktDropEndTime
                Unsigned32
}

bulkTimedDosPktDropIndex OBJECT-TYPE
        SYNTAX  INTEGER
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "The bulk index ."
        ::= { bulkTimedDosPktDropEntry 1 }

bulkTimedDosPktDropVidsId OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The Vids identifier."
        ::= { bulkTimedDosPktDropEntry 2 }

bulkTimedDosPktDropNiId OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The NI identifier."
        ::= { bulkTimedDosPktDropEntry 3 }

bulkTimedDosPktDropMsrId OBJECT-TYPE
        SYNTAX  INTEGER
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The MeasureId identifier."
        ::= { bulkTimedDosPktDropEntry 4 }

bulkTimedDosPktDropEndTime OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The absolute end time when the duration for intended action expires."
        ::= { bulkTimedDosPktDropEntry 5 }

internalVLANId  OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object identifies the VLAN ID to be used by the sensor to tag 
                any untagged pkts on Rx, and untag them on Tx. It must not match any 
                other VLAN ID assigned for the customer network. Default: 4095 
                "
        ::= { dosConfigGrp 9 }

--This group contians MIB objects for configuration of packet logging.
--The <pktLogServerIPAddress> identifies the IP address of the server
--receiving packets that the Sensor logs when detecting attacks.
--The <pktLogServerPort> identifies the TCP port on this server
--that receives the logged packets.

pktLogGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 15 }

pktLogServerIPAddress  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"IP Address"
	::= { pktLogGrp 1 }

pktLogServerPort  OBJECT-TYPE
	SYNTAX 	Integer32 (1..10000)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"TCP Port on which the pkt log server can receive packet 
                 logs from the IntruShield IDS."
	::= { pktLogGrp 2 }

pktLogMaxPacketsPerFlow  OBJECT-TYPE
	SYNTAX 	Integer32 (0..64000)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Number of packets per flow which need to be logged,
		 0 means log entire flow.
		 Default: 1000"
	::= { pktLogGrp 3 }

pktLogEncryptionEnable  OBJECT-TYPE
	SYNTAX INTEGER {
		enable (1)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object can be used to enable encryption of packet log channel. 
		RC4 will be used for encryption.
		Default: enable (1)"
	::= { pktLogGrp 4 } 

pktLogServerIPv6Address  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"IPv6 Address of the ISM to which the logs need to be delivered. 
		 ISM should set either the Ipv4 or the Ipv6 address."
	::= { pktLogGrp 5 }

--This group contians MIB objects for configuration of alert throttling.

pktAlertThrottleGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 16 }

pktAlertThrottleGlobalThreshold OBJECT-TYPE
	SYNTAX 	INTEGER (1..32)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Once this threshold is exceeded, sensor will only send one
		summary alert for all addresses (srcip's and destip's) that 
		match the attackid/vidsid.

		Default: 10"
	::= { pktAlertThrottleGrp 1 }

pktAlertThrottleInterval  OBJECT-TYPE
	SYNTAX 	INTEGER (1..3600)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If the number of alerts exceeds the amount configured
		in pktAlertThrottleThreshold or 
		pktAlertThrottleGlobalThreshold in pktAlertThrottleInterval
		seconds, alerts will be throttled.

		Units are in seconds.

		Default: 120 seconds"
	::= { pktAlertThrottleGrp 2 }

pktAlertThrottleAction  OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object can be used to enable and disable alert
		throttling.

		Default: enable(1)"
	::= { pktAlertThrottleGrp 3 }

pktAlertThrottleThreshold  OBJECT-TYPE
	SYNTAX 	INTEGER (1..25)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to configure the number of alerts that
		need to be sent before sensor starts to throttle the alerts.
		For example if this value is 10, it will send the first 10
		alerts with the following key: attackid/vidsid/srcip/destip.
		This parameters will use the pktAlertThrottleInterval as the
		interval.

		Default: 5"
	::= { pktAlertThrottleGrp 4 }

pktAlertCorrelationTime  OBJECT-TYPE
	SYNTAX 	INTEGER (1..20)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to configure the time that the sensor will
                correlate multiple signatures for a single attack and only send
                the signature with the lowest benign trigger probability.

		Default: 5 secs"
	::= { pktAlertThrottleGrp 5 }


sslConfigGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 17 }

sslSessionCacheLifetime OBJECT-TYPE
        SYNTAX  INTEGER (0..4294967296)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Duration in minutes for which the SSL Session is kept alive, inspite of no 
                SSL data transfer between the client/server .
                Default: 5"
        ::= { sslConfigGrp 1 }

sslSupportAction  OBJECT-TYPE
	SYNTAX 	INTEGER (0..100000)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object can be used to enable support for specific ssl flow count (non 0) 
                and disable SSL (0) on sensor.  Sensor reboot is typically required to activate 
                support of requested flow count.
                EMS must check for max requested ssl flows based on product type:
                 I4000: 100K, I2600: 25K , I1200: not supported.
                Default: not supported (0)"
        ::= { sslConfigGrp 2 }

sslSupportStatus  OBJECT-TYPE
	SYNTAX 	INTEGER (0..100000)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object can be used to get SSL support status on sensor. It will show 0 if disabled, or a non 0 value indicating the ssl flow count currently supported. User must reboot sensor to ensure that requested flow count is actually supported by sensor.
     EMS must check for max supported ssl flows based on product type:
                 I4000: 100K, I2600: 25K , I1200: not supported.
                Default: not supported (0)"
        ::= { sslConfigGrp 3 }

sslSessionRemoveCerts  OBJECT-TYPE
        SYNTAX  INTEGER {
                reset (0)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Delete all ssl certs, thereby terminating decryption of related ssl traffic, but leave ssl support enabled within sensor."
        ::= { sslConfigGrp 4 }

sslPktLoggingEnable OBJECT-TYPE
        SYNTAX  INTEGER {
		enable (1),
		disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Specifies if sensor should log decrypted SSL packets or not. 

                Default: 2, disabled"
        ::= { sslConfigGrp 5 }

sslModesofOperation OBJECT-TYPE
        SYNTAX  INTEGER{
               disable (0),
               inbound-known-key-only(1),
               outbound-proxy-only (2),
               inbound-proxy-only (3),
               inbound-and-outbound-proxy (4),
               inbound-known-key-and-outbound-proxy (5)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Determines the SSL decryption direction and method.
                disable(0) - No SSL decryption performed for traffic.
                inbound known key only(1) - Only Inbound SSL decryption using RSA key exchange. 
                outbound proxy only(2) - Only Outbound SSL using MITM proxy
                inbound proxy only(3) - Only Inbound SSL using MITM Proxy
                inbound and outbound proxy(4) - Inbound and Outbound proxy using MITM Proxy
                inbound known key and outbound proxy(5) - Inbound using RSA key exchange and Outbound using MITM Proxy
                Default:  disable (0)"
        ::= { sslConfigGrp 6 }

sslSessionCacheLifetimeOutbound OBJECT-TYPE
        SYNTAX  INTEGER (0..4294967296)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Duration in minutes for which the SSL Session is kept alive, inspite of no
                SSL data transfer between the client/server. This setting will be applied for
                SSL traffic in Outbound direction.
                This is not applicable on I-series and M-series
                Default: 5"
        ::= { sslConfigGrp 7 }

sslPktLoggingOutboundEnable OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Specifies if sensor should log decrypted SSL packets or not on the Outbound direction.
                This is not applicable on I-series and M-series
                Default: 2, disabled"
        ::= { sslConfigGrp 8 }

sslProxyOutboundUnknownServerCertificate OBJECT-TYPE
        SYNTAX  INTEGER {
                ignore (1),
                block (2),
                decrypt (3)
        }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
                "This object will be used to configure the action that the sensor will need to
                 take when the sensor is unable to verify the validaity of the certificate.
                 This is not applicable on I-series and M-series
                Default: decrypt(3)"
        ::= { sslConfigGrp 9 }


sslProxyOutboundUntrustedServerCertficate  OBJECT-TYPE
        SYNTAX  INTEGER {
                ignore (1),
                block (2),
                decrypt (3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object will be used to configure the action that the sensor will need to take
                 when the sensor receives an untrusted certificate from the external server. This could
                 be either due to certificate not being trusted by any root CA, expired, revoked etc.
                 This is not applicable on I-series and M-series
                Default: decrypt (3)"
        ::= { sslConfigGrp 10 }

sslProxyOutboundUnsupportedCipherSuite  OBJECT-TYPE
        SYNTAX  INTEGER {
                ignore (1),
                block (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object will be used to configure the action that the sensor will need to take when an
                 internal client sends a list of ciphers and the sensor does not support any of the cipher suite
                 This is not applicable on I-series and M-series
                Default: ignore (1)"
        ::= { sslConfigGrp 11 }

sslProxyInboundUnsupportedCipherSuite  OBJECT-TYPE
        SYNTAX  INTEGER {
                ignore (1),
                block (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This is reserved for future used. This object is not currently implemented.
                 This object will be used to configure the action that the sensor will need to take when an
                 external client sends a list of ciphers and the sensor does not support any of the cipher suite
                 This is not applicable on I-series and M-series
                Default: ignore (1)"
        ::= { sslConfigGrp 12 }

sslProxyOutboundUnsupportedServerCertificate  OBJECT-TYPE
        SYNTAX  INTEGER {
                ignore (1),
                block (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object will be used to configure the action that the sensor will need to take
                 when the sensor encounters an unsupported server certificate in an outbound direction.
                 This is not applicable on I-series and M-series
                Default: ignore (1)"
        ::= { sslConfigGrp 13 }

sslProxyInboundUnsupportedServerCertificate  OBJECT-TYPE
        SYNTAX  INTEGER {
                ignore (1),
                block (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This is reserved for future used. This object is not currently implemented.
                This object will be used to configure the action that the sensor will need to take
                 when the sensor encounters an unsupported server certificate in an inbound direction.
                 This is not applicable on I-series and M-series
                Default: ignore (1)"
        ::= { sslConfigGrp 14 }

maxSslFlowSupportedInSslDisableMode OBJECT-TYPE
        SYNTAX  INTEGER (0..100000)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "This object specifies the max number of SSL flows supported when SSL is disabled on the sensor."
        ::= { sslConfigGrp 15 }

maxFlowSupportedInSslDisableMode OBJECT-TYPE
        SYNTAX  INTEGER (0..100000)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "This object specifies the max number of flows supported by sensor when SSL is disabled on the sensor."
        ::= { sslConfigGrp 16 }

maxSslFlowSupportedInSslInboundLegacyMode OBJECT-TYPE
        SYNTAX  INTEGER (0..100000)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "This object specifies the max number of SSL flows supported when SSL is enabled in inbound legacy mode."
        ::= { sslConfigGrp 17 }

maxFlowSupportedInSslInboundLegacyMode OBJECT-TYPE
        SYNTAX  INTEGER (0..100000)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "This object specifies the max number of flows supported by sensor when SSL is enabled in inbound legacy mode"
        ::= { sslConfigGrp 18 }

maxSslFlowSupportedInSslOutboundMode OBJECT-TYPE
        SYNTAX  INTEGER (0..100000)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "This object specifies the max number of SSL flows supported when SSL is enabled in outbound mode."
        ::= { sslConfigGrp 19 }

maxFlowSupportedInSslOutboundMode OBJECT-TYPE
        SYNTAX  INTEGER (0..100000)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "This object specifies the max number of flows supported by sensor when SSL is enabled in outbound mode"
        ::= { sslConfigGrp 20 }

sslModesofOperationStatus OBJECT-TYPE
        SYNTAX  INTEGER{
               disable (0),
               inbound-known-key-only(1),
               outbound-proxy-only (2),
               inbound-proxy-only (3),
               inbound-and-outbound-proxy (4),
               inbound-known-key-and-outbound-proxy (5)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "Provides current SSL decryption method used in Sensor for inbound traffic.
                disable(0) - No SSL decryption performed for traffic.
                inbound known key only(1) - Only Inbound SSL decryption using RSA key exchange.
                outbound proxy only(2) - Only Outbound SSL using MITM proxy
                inbound proxy only(3) - Only Inbound SSL using MITM Proxy
                inbound and outbound proxy(4) - Inbound and Outbound proxy using MITM Proxy
                inbound known key and outbound proxy(5) - Inbound using RSA key exchange and Outbound using MITM Proxy
                Default:  disable (0)"
         ::= { sslConfigGrp 21 }

sslProxyOutboundUnknownURLCategory  OBJECT-TYPE
        SYNTAX  INTEGER {
                ignore (1),
                decrypt (3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object will be used to configure the action that the sensor will need to take
                 when the sensor identifies an unknown url category in the ssl packet. This configuration
                 is only supported in case of outbound ssl.
                 This is not applicable on I-series and M-series
                Default: ignore (1)"
        ::= { sslConfigGrp 22 }

sslShKeyDecryptEnable OBJECT-TYPE
        SYNTAX  INTEGER {
		enable (1),
		disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Specifies if sensor should decrypt using shared keys from SSL probes. 
                Default: 2, disabled"
        ::= { sslConfigGrp 23 }

---
---
---


l2ConfigGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 18 }

l2ModeEnable OBJECT-TYPE
        SYNTAX  INTEGER {
		enable (1),
		disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This specifies if sensor is configured to detect failure and go into L2 mode on exceeding cfg threshold within cfg duration.

                Default: 2, disabled"
        ::= { l2ConfigGrp 1 }

l2ModeStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                layer2Mode(1),
                ipsMode(2)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object identifies the mode the sensor is currently in."

        ::= { l2ConfigGrp 2 }

l2ModeCfgDuration  OBJECT-TYPE
        SYNTAX  INTEGER (1..60)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the time duration input criteria for enabling the sensor in layer2 mode.

                Default: 10 mins"
        ::= { l2ConfigGrp 3 }

l2ModeCfgThreshold  OBJECT-TYPE
        SYNTAX  INTEGER (1..10)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the event frequency input criteria for enabling the sensor in layer2 mode.

                Default: 1"
        ::= { l2ConfigGrp 4 }

l2ModeOccCount  OBJECT-TYPE
        SYNTAX  INTEGER (0..10)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object identifies the frequency of event occurence when ensor was last enabled in layer2 mode.

                "
        ::= { l2ConfigGrp 5 }

l2ModeReason  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..127))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object contains reason for sensor to enter into Layer-2 mode."
        ::= { l2ConfigGrp 6 }


-- acl Logging support on the Sensor

aclLogAlertGrp	OBJECT IDENTIFIER ::=  { ivSensorConfigurationMIB 19 }

aclAlertLogging	OBJECT-TYPE
	SYNTAX	INTEGER {
		g-enable-dropped (1),
		g-enable-allowed (2),
		g-enable-all (3),
		enable-per-acl (4),
		disable (5)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION   
 		"This object specifies various ways to enable ACL Alert logging or disable it altogether.
		This is applicable on a sensor wide basis for all ports in inline mode.
		Default: disable (5)"
	::= { aclLogAlertGrp 1 }

aclAlertThrottleMaxIpPair OBJECT-TYPE
        SYNTAX  INTEGER (1..32)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Once this threshold is exceeded, sensor will only send one
                summary acl alert for all addresses (srcip's and destip's) that
                match the aclid/vidsid.

                Default: 10"
        ::= { aclLogAlertGrp 2 }

aclAlertThrottleInterval  OBJECT-TYPE
        SYNTAX  INTEGER (1..3600)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "If the number of acl alerts exceeds the amount configured
                in aclAlertThrottleThreshold in aclAlertThrottleInterval
                seconds, alerts will be throttled.

                Units are in seconds.

                Default: 120 seconds"
        ::= { aclLogAlertGrp 3 }


aclAlertThrottleAction  OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object can be used to enable and disable acl alert
                throttling.

                Default: enable(1)"
        ::= { aclLogAlertGrp 4 }

aclAlertThrottleThreshold  OBJECT-TYPE
        SYNTAX  INTEGER (1..25)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the number of alerts that
                need to be sent before sensor starts to throttle the alerts.
                For example if this value is 10, it will send the first 10
                alerts with the following key: aclid/vidsid/srcip/destip.
                This parameters will use the aclAlertThrottleInterval as the
                interval.

                Default: 5"
        ::= { aclLogAlertGrp 5 }

aclAlertDirectToSyslog  OBJECT-TYPE
        SYNTAX  INTEGER {
                sendViaNSM (1),
                sendDirect (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object can be used to enable sending acl logs directly to syslog viewer instead of sending it via NSM.
         Default: sendViaNSM (1)"
        ::= { aclLogAlertGrp 6 }

--User authentication using TACACS+ 

tacacsPlusAuthGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 20 }

enableTacacsPlusAuth  OBJECT-TYPE
	SYNTAX INTEGER {
		enable (1),
		disable (2)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object can be used to enable or disable user authentication & accounting using TACACS+.
		Default: disable (2)"
	::= { tacacsPlusAuthGrp 1}

enableTacacsPlusTrafficEncr OBJECT-TYPE
	SYNTAX INTEGER {
		enable (1),
		disable	(2)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object can be used to enable or disable encryption of  TACACS+ traffic.
		Default: disable (2)"
	::= { tacacsPlusAuthGrp 2}

tacacsPlusEncrSecret OBJECT-TYPE
	SYNTAX DisplayString (SIZE(0..64))
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object specifies the secret to be used in generating the encrypted TACACS+ traffic"
	::= { tacacsPlusAuthGrp 3}


tacacsPlusServerIPTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF TacacsPlusServerIPEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
		"This table contains entries that specifiy the IP addresses of the TACACS+ servers"
	::= { tacacsPlusAuthGrp 4}

tacacsPlusServerIPEntry  OBJECT-TYPE
	SYNTAX  TacacsPlusServerIPEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	"This table entry specifies the IP address of the TACACS+ server"
	INDEX { tacIndex }
	 ::= { tacacsPlusServerIPTable 1 }


TacacsPlusServerIPEntry ::= SEQUENCE {
	tacIndex
		INTEGER,
	tacacsPlusServerIPAddr
		IpAddress
	}

tacIndex  OBJECT-TYPE
	SYNTAX  INTEGER
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
		"Fixed index for the four TACACS+ Server entries. Valid values are [1,2,3,4] only."
	::= { tacacsPlusServerIPEntry 1 }

tacacsPlusServerIPAddr OBJECT-TYPE
	SYNTAX IpAddress
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
	"This object specifies the IP Address of the TACACS+ server"
	::= { tacacsPlusServerIPEntry 2 }

enableTacacsPlusAuthorization OBJECT-TYPE
    SYNTAX INTEGER
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	        "To enable TACACS Plus authorization"
	::= { tacacsPlusAuthGrp 5 }

-- ipV6  support on sensor 

ipV6ConfigGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 21 }

ipV6TrafficHandling OBJECT-TYPE
        SYNTAX INTEGER {
              dont-parse-block-inline (1),  
              dont-parse-allow-inline (2),   
              parse-and-detect-attacks (3)    
        }
        MAX-ACCESS  read-write
	  STATUS  current
        DESCRIPTION
             "This object can be used to specify how the IPv6 traffic is handled on all ports of a sensor.
              dont-parse-block-inline - Traffic will not be subjected to IPS/IDS.  On Inline ports, traffic will be blocked.
              dont-parse-allow-inline  -  Traffic will not be subjected to IPS/IDS.  On Inline ports , traffic wll be allowed to go through the sensor.
              parse-and-detect-attacks  - Parse and detect attacks in IPv6 traffic and pass the traffic on inline ports
              Default: dont-parse-allow-inline(2)"
                ::= { ipV6ConfigGrp 2}
                
-- Host Quarantine Config Group
--
hostQGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 22 }

--
-- Host Quarantine Config Table
--
-- This group conatins all MIB objects that specify the configuration for
-- reconfiguring the hostQ. 
--
hostQConfigGrp  OBJECT IDENTIFIER ::= { hostQGrp  1 }

hostQFilterTimeOut OBJECT-TYPE
	SYNTAX 	INTEGER (5..60)
	MAX-ACCESS  read-write
	STATUS	obsolete
	DESCRIPTION 
		"The number of minutes for which this entry should be in
		affect.

		Default: 5 minutes"
	::= { hostQConfigGrp 1 }

hostQDeleteAllFilters OBJECT-TYPE
	SYNTAX 	INTEGER {
		not-applicable(0),
		true(1)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"If set to not-applicable(0), applied filters are not 
		deleted. If set to true (1) all filters are deleted.

		Default: not-applicable (0)"
	::= { hostQConfigGrp 2 }

--
-- Host Quarantine Bulk IPV4 Filter table 
--
-- This group defines filter entries that have been applied on the sensor in
-- Inline mode. This table only supports GET-NEXT operations. All entries are
-- read-only. The table will have a maximum of 1000 entries.
--
hostQBulkFilterV4Table  OBJECT-TYPE
	SYNTAX SEQUENCE OF HostQBulkFilterV4Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table containing entries for filters that are applied on the \
		 sensor  in Inline mode. This table supports only GET-NEXT operations"
	::= { hostQGrp  2 }

hostQBulkFilterV4Entry  OBJECT-TYPE
	SYNTAX 	HostQBulkFilterV4Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Indexed by sequence number."
	INDEX { hostQBulkFilterIndexV4 }
	::= { hostQBulkFilterV4Table 1 }

HostQBulkFilterV4Entry ::= SEQUENCE {
	hostQBulkFilterIndexV4
		INTEGER,
	hostQBulkFilterSrcIPAddrV4
		IpAddress,
	hostQBulkFilterVidsIdV4
		INTEGER,
	hostQBulkFilterAttackIdV4
		INTEGER,
	hostQBulkFilterEndTimeV4
		Unsigned32,
	hostQBulkFilterQRStatusV4
		INTEGER,
	hostQBulkFilterMPEReplyMsgV4
		INTEGER,
	hostQBulkFilterMonPortIdV4
		TrellixPortLinearIndex,
	hostQBulkFilterEZIdV4
		INTEGER
}

hostQBulkFilterIndexV4 OBJECT-TYPE
	SYNTAX 	INTEGER  
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Index which uniquely identifies the V4 filter rule"
	::= { hostQBulkFilterV4Entry 1 }

hostQBulkFilterSrcIPAddrV4  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Source IPV4 Address."
	::= { hostQBulkFilterV4Entry 2 }

hostQBulkFilterVidsIdV4  OBJECT-TYPE
   SYNTAX   INTEGER
   MAX-ACCESS  read-only
   STATUS   current
   DESCRIPTION
      "This objects returns the vids id for which this filter
      was applied."
   ::= { hostQBulkFilterV4Entry 3 }

hostQBulkFilterAttackIdV4  OBJECT-TYPE
   SYNTAX   INTEGER
   MAX-ACCESS  read-only
   STATUS   current
   DESCRIPTION
      "This objects returns the attack id for which this filter
      was applied."
   ::= { hostQBulkFilterV4Entry 4 }

hostQBulkFilterEndTimeV4  OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This objects returns the filter expiry time in UTC format "
	::= { hostQBulkFilterV4Entry 5 }


hostQBulkFilterQRStatusV4 OBJECT-TYPE
	SYNTAX 	INTEGER {
		hostQuarantined-local(1),
		hostUnderRemediation-local(2),
		hostQuarantined-mpe(4),
		hostQuarantined-both(5),
		hostUnderRemediation-local-hostQuarantined-mpe(6),
		hostUnderRemediation-mpe(8),
		hostQuarantined-local-hostUnderRemediation-mpe(9),
		hostUnderRemediation-both(10)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This objects returns the host quarantine and remediation action status."
	::= { hostQBulkFilterV4Entry 6 }

hostQBulkFilterMPEReplyMsgV4 OBJECT-TYPE
	SYNTAX 	INTEGER
	{
		notApplicable(0),
		managedHost(1),
		unmanagedHost(2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This objects returns the message returned by the MPE server."
	::= { hostQBulkFilterV4Entry 7 }

hostQBulkFilterMonPortIdV4  OBJECT-TYPE
   SYNTAX   TrellixPortLinearIndex
   MAX-ACCESS  read-only
   STATUS   current
   DESCRIPTION
      "This objects returns the monitoring linear port index on which the attack was detected for 
	the quarantined host."
   ::= { hostQBulkFilterV4Entry 8 }


hostQBulkFilterEZIdV4  OBJECT-TYPE
   SYNTAX   INTEGER
   MAX-ACCESS  read-only
   STATUS   current
   DESCRIPTION
      "This objects returns the applied NAZ Id for the quarantined host."
   ::= { hostQBulkFilterV4Entry 9 }

--
-- Host Quarantine Bulk IPV6 Filter table
--
-- This group defines filter entries that have been applied on the sensor in
-- Inline mode. This table only supports GET-NEXT operations. All entries are
-- read-only. The table will have a maximum of 1000 entries.
--

hostQBulkFilterV6Table  OBJECT-TYPE
	SYNTAX SEQUENCE OF HostQBulkFilterV6Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table containing entries for IPv6 filters that are applied on the 
		 sensor  in Inline mode."
	::= { hostQGrp  3 }

hostQBulkFilterV6Entry  OBJECT-TYPE
	SYNTAX 	HostQBulkFilterV6Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Indexed by sequence number."
	INDEX { hostQBulkFilterIndexV6 }
	::= { hostQBulkFilterV6Table 1 }

HostQBulkFilterV6Entry ::= SEQUENCE {
	hostQBulkFilterIndexV6
		INTEGER,
	hostQBulkFilterSrcIPAddrV6
		Ipv6Address,
	hostQBulkFilterVidsIdV6
		INTEGER,
   	hostQBulkFilterAttackIdV6
      		INTEGER,
   	hostQBulkFilterEndTimeV6
      		Unsigned32,
	hostQBulkFilterQRStatusV6
		INTEGER,
	hostQBulkFilterMPEReplyMsgV6
		INTEGER,
	hostQBulkFilterMonPortIdV6
		TrellixPortLinearIndex
}

hostQBulkFilterIndexV6 OBJECT-TYPE
	SYNTAX 	INTEGER  
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Index which uniquely identifies the IPv6 filter rule."
	::= { hostQBulkFilterV6Entry 1 }

hostQBulkFilterSrcIPAddrV6  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Source IPV6 Address."
	::= { hostQBulkFilterV6Entry 2 }

hostQBulkFilterVidsIdV6  OBJECT-TYPE
   SYNTAX   INTEGER
   MAX-ACCESS  read-only
   STATUS   current
   DESCRIPTION
      "This objects returns the vids id for which this filter
      was applied."
   ::= { hostQBulkFilterV6Entry 3 }

hostQBulkFilterAttackIdV6  OBJECT-TYPE
   SYNTAX   INTEGER
   MAX-ACCESS  read-only
   STATUS   current
   DESCRIPTION
      "This objects returns the attack id for which this filter
      was applied."
   ::= { hostQBulkFilterV6Entry 4 }

hostQBulkFilterEndTimeV6  OBJECT-TYPE
	SYNTAX 	Unsigned32
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This objects returns the filter expiry time in UTC format."
	::= { hostQBulkFilterV6Entry 5 }

hostQBulkFilterQRStatusV6  OBJECT-TYPE
	SYNTAX 	INTEGER {
		hostQuarantined-local(1),
		hostUnderRemediation-local(2),
		hostQuarantined-mpe(4),
		hostQuarantined-both(5),
		hostUnderRemediation-local-hostQuarantined-mpe(6),
		hostUnderRemediation-mpe(8),
		hostQuarantined-local-hostUnderRemediation-mpe(9),
		hostUnderRemediation-both(10)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This objects returns the host quarantine and remediation action status."
	::= { hostQBulkFilterV6Entry 6 }

hostQBulkFilterMPEReplyMsgV6  OBJECT-TYPE
	SYNTAX 	INTEGER
	{
		notApplicable(0),
		managedHost(1),
		unmanagedHost(2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This objects returns the message returned by the MPE server."
	::= { hostQBulkFilterV6Entry 7 }

hostQBulkFilterMonPortIdV6  OBJECT-TYPE
   SYNTAX   TrellixPortLinearIndex
   MAX-ACCESS  read-only
   STATUS   current
   DESCRIPTION
      "This objects returns the monitoring linear port index on which the attack was detected for 
	the quarantined Ipv6 host."
   ::= { hostQBulkFilterV6Entry 8 }

--
-- Host Quarantine Never Deny V4 Table
--
hostQNeverDenyV4Table  OBJECT-TYPE
	SYNTAX SEQUENCE OF HostQNeverDenyV4Entry
	MAX-ACCESS  not-accessible
	STATUS	obsolete
	DESCRIPTION 
		"Table defines ipaddresses from which traffic is never
		blocked. Typically user will add all the critical network
		elements like routers, servers, etc."
	::= { hostQGrp 4 }

hostQNeverDenyV4Entry  OBJECT-TYPE
	SYNTAX 	HostQNeverDenyV4Entry
	MAX-ACCESS  not-accessible
	STATUS	obsolete
	DESCRIPTION 
		"Indexed by hostQNeverDenyIpAddress. Supports up to 100 entries."
	INDEX {hostQNeverDenyIpAddressV4  }
	::= { hostQNeverDenyV4Table 1 }

HostQNeverDenyV4Entry ::= SEQUENCE {
	hostQNeverDenyIpAddressV4
		IpAddress,
	hostQNeverDenyActionV4
		RowStatus
}

hostQNeverDenyIpAddressV4 OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  not-accessible
	STATUS	obsolete
	DESCRIPTION 
		"The ipV4 address from which traffic will never be blocked."
	::= { hostQNeverDenyV4Entry 1 }

hostQNeverDenyActionV4 OBJECT-TYPE
	SYNTAX 	RowStatus
	MAX-ACCESS  read-create
	STATUS	obsolete
	DESCRIPTION 
		"This object is to user to add and delete rows in to the
		table."
	::= { hostQNeverDenyV4Entry 2 }

--
-- Host Quarantine Never Deny V6 Table
--
hostQNeverDenyV6Table  OBJECT-TYPE
	SYNTAX SEQUENCE OF HostQNeverDenyV6Entry
	MAX-ACCESS  not-accessible
	STATUS	obsolete
	DESCRIPTION 
		"Table defines ipaddresses from which traffic is never
		blocked. Typically user will add all the critical network
		elements like routers, servers, etc."
	::= { hostQGrp 5 }

hostQNeverDenyV6Entry  OBJECT-TYPE
	SYNTAX 	HostQNeverDenyV6Entry
	MAX-ACCESS  not-accessible
	STATUS	obsolete
	DESCRIPTION 
		"Indexed by hostQNeverDenyIpAddress. Supports up to 100 entries."
	INDEX {hostQNeverDenyIpAddressV6  }
	::= { hostQNeverDenyV6Table 1 }

HostQNeverDenyV6Entry ::= SEQUENCE {
	hostQNeverDenyIpAddressV6
		Ipv6Address,
	hostQNeverDenyActionV6
		RowStatus
}

hostQNeverDenyIpAddressV6 OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  not-accessible
	STATUS	obsolete
	DESCRIPTION 
		"The ipV6 address from which traffic will never be blocked."
	::= { hostQNeverDenyV6Entry 1 }

hostQNeverDenyActionV6 OBJECT-TYPE
	SYNTAX 	RowStatus
	MAX-ACCESS  read-create
	STATUS	obsolete
	DESCRIPTION 
		"This object is to user to add and delete rows in to the
		table."
	::= { hostQNeverDenyV6Entry 2 }


--
-- Host Quarantine User Define V4 Filter Table (does not support GET-NEXT operations)
--

hostQUserDefFilterV4Table OBJECT-TYPE
	SYNTAX SEQUENCE OF HostQUserDefFilterV4Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table is used to add/delete/extend IPv4 filters on the sensor"
	::= { hostQGrp 6 }

hostQUserDefFilterV4Entry  OBJECT-TYPE
	SYNTAX 	HostQUserDefFilterV4Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		""
	INDEX { hostQUserDefFilterSrcIpV4, hostQUserDefFilterVidsIdV4, hostQUserDefFilterAttackIdV4 }
	::= { hostQUserDefFilterV4Table 1 }

HostQUserDefFilterV4Entry ::= SEQUENCE {
	hostQUserDefFilterSrcIpV4
		IpAddress,
	hostQUserDefFilterVidsIdV4
		INTEGER,
	hostQUserDefFilterAttackIdV4
		INTEGER,
	hostQUserDefFilterDurationV4
		Unsigned32,
	hostQUserDefFilterActionV4
		INTEGER,
	hostQUserDefFilterRemediationV4
		TruthValue	
}

hostQUserDefFilterSrcIpV4 OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Source IPV4 address."
	::= { hostQUserDefFilterV4Entry 1 }

hostQUserDefFilterVidsIdV4 OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Vids ID."
	::= { hostQUserDefFilterV4Entry 2 }

hostQUserDefFilterAttackIdV4 OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS not-accessible
	STATUS	current
	DESCRIPTION 
		"Attack ID."
	::= { hostQUserDefFilterV4Entry 3 }

hostQUserDefFilterDurationV4 OBJECT-TYPE
   SYNTAX  Unsigned32
   MAX-ACCESS  read-write
   STATUS   current
   DESCRIPTION
      "Filter duration"
   ::= { hostQUserDefFilterV4Entry 4 }

hostQUserDefFilterActionV4 OBJECT-TYPE
        SYNTAX  INTEGER {
                not-applicable (0),
                add (1),
					 delete (2)
        }
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
                "Setting this object to add(1) will add the entry."
	::= { hostQUserDefFilterV4Entry 5 }

hostQUserDefFilterRemediationV4 OBJECT-TYPE
        SYNTAX  TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
                "Setting this object to TRUE, will enable host rememdiation for the user defined quarantine rule.
		 Default : FALSE"
	::= { hostQUserDefFilterV4Entry 6 }

--
-- Host Quarantine User Define V6 Filter Table
--

hostQUserDefFilterV6Table OBJECT-TYPE
	SYNTAX SEQUENCE OF HostQUserDefFilterV6Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table is used to add/delete/extend IPv6 filters on the sensor" 
	::= { hostQGrp 7 }

hostQUserDefFilterV6Entry  OBJECT-TYPE
	SYNTAX 	HostQUserDefFilterV6Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		""
	INDEX {hostQUserDefFilterSrcIpV6, hostQUserDefFilterVidsIdV6, hostQUserDefFilterAttackIdV6 }
	::= { hostQUserDefFilterV6Table 1 }

HostQUserDefFilterV6Entry ::= SEQUENCE {
	hostQUserDefFilterSrcIpV6
		Ipv6Address,
	hostQUserDefFilterVidsIdV6
		INTEGER,
	hostQUserDefFilterAttackIdV6
		INTEGER,
	hostQUserDefFilterDurationV6
	      Unsigned32,
	hostQUserDefFilterActionV6
		INTEGER
}

hostQUserDefFilterSrcIpV6 OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Source IPV6 address."
	::= { hostQUserDefFilterV6Entry 1 }

hostQUserDefFilterVidsIdV6 OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Vids ID."
	::= { hostQUserDefFilterV6Entry 2 }

hostQUserDefFilterAttackIdV6 OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS not-accessible
	STATUS	current
	DESCRIPTION 
		"Attack ID."
	::= { hostQUserDefFilterV6Entry 3 }

hostQUserDefFilterDurationV6 OBJECT-TYPE
   SYNTAX  Unsigned32
   MAX-ACCESS  read-write
   STATUS   current
   DESCRIPTION
      "Filter duration"
   ::= { hostQUserDefFilterV6Entry 4 }

hostQUserDefFilterActionV6 OBJECT-TYPE
        SYNTAX  INTEGER {
                not-applicable (0),
                add (1),
                delete(2)
        	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
                "Setting this object to add(1) will add the entry."
	::= { hostQUserDefFilterV6Entry 5 }

--
-- nmsGrp 
--

nmsGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 23 }

nmsUserGrp  OBJECT IDENTIFIER ::= { nmsGrp  1 }

nmsUserTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF NMSUserEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"
		
		"
	::= { nmsUserGrp 1 }

nmsUserEntry  OBJECT-TYPE
	SYNTAX 	NMSUserEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Each entry specified is indexed by <nmsUserIndex>. 
		Additonaly it contains the 
		"
	INDEX { nmsUserName }
	::= { nmsUserTable 1 }

NMSUserEntry ::= SEQUENCE {
	nmsUserName
		DisplayString,
	nmsAuthKey
		DisplayString,
	nmsEncrKey
		DisplayString,
	nmsUserChangeAction
		RowStatus
}

nmsUserName  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(8..31))	
	MAX-ACCESS 	not-accessible 
	STATUS	current
	DESCRIPTION 
		"UserName nms (in this entry)."
	::= { nmsUserEntry 1 }

nmsAuthKey  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(8..15))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"NMS Auth Key"
	::= { nmsUserEntry 2 }

nmsEncrKey  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(8..15))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"NMS Encryption Key."
	::= { nmsUserEntry 3 }

nmsUserChangeAction  OBJECT-TYPE
	SYNTAX  RowStatus
	MAX-ACCESS  read-create
	STATUS  current
	DESCRIPTION
		"This object used for user to add and delete rows in to the table"
	::= { nmsUserEntry 4 }

nmsDeleteAllUsers OBJECT-TYPE
	SYNTAX 	INTEGER {
		true(1)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This action object deletes all user entries in the nmsUserTable."
	::= { nmsUserGrp 2 }

nmsCommitUserEntryChanges OBJECT-TYPE
	SYNTAX 	INTEGER {
		true(1)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This action object commits all the changes made to the user entries in the nmsUserTable."
	::= { nmsUserGrp 3 }


nmsIpGrp  OBJECT IDENTIFIER ::= { nmsGrp  2 }

nmsIpTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF NMSIpEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"
		
		"
	::= { nmsIpGrp 1 }

nmsIpEntry  OBJECT-TYPE
	SYNTAX 	NMSIpEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Each entry specified is indexed by <nmsIpIndex>. 
		Additonaly it contains the 
		"
	INDEX { nmsIpAddress }
	::= { nmsIpTable 1 }

NMSIpEntry ::= SEQUENCE {
	nmsIpAddress
		IpAddress,
	nmsIpChangeAction
		RowStatus	
}

nmsIpAddress  OBJECT-TYPE
	SYNTAX IpAddress	
	MAX-ACCESS	not-accessible 
	STATUS	current
	DESCRIPTION 
		"UserName nms (in this entry)."
	::= { nmsIpEntry 1 }

nmsIpChangeAction  OBJECT-TYPE
	SYNTAX 	RowStatus 
	MAX-ACCESS  read-create
	STATUS  current
	DESCRIPTION
		"This object used for user to add and delete rows in to the table."
	::= { nmsIpEntry 2 }

nmsIpv6Table  OBJECT-TYPE
	SYNTAX SEQUENCE OF NMSIpv6Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"
		
		"
	::= { nmsIpGrp 2 }

nmsIpv6Entry  OBJECT-TYPE
	SYNTAX 	NMSIpv6Entry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Each entry specified is indexed by <nmsIpv6Index>. 
		"
	INDEX { nmsIpv6Address }
	::= { nmsIpv6Table 1 }

NMSIpv6Entry ::= SEQUENCE {
	nmsIpv6Address
		Ipv6Address,
	nmsIpv6ChangeAction
		RowStatus	
}

nmsIpv6Address  OBJECT-TYPE
	SYNTAX Ipv6Address	
	MAX-ACCESS	not-accessible 
	STATUS	current
	DESCRIPTION 
		"IPv6 address of the system having SNMP access to the sensor"
	::= { nmsIpv6Entry 1 }

nmsIpv6ChangeAction  OBJECT-TYPE
	SYNTAX 	RowStatus 
	MAX-ACCESS  read-create
	STATUS  current
	DESCRIPTION
		"This object used for user to add and delete rows in to the table."
	::= { nmsIpv6Entry 2 }

--
-- mpeGrp 
--

mpeGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 24 }

mpeConfigGrp  OBJECT IDENTIFIER ::= { mpeGrp  1 }

mpeQRScope  OBJECT-TYPE
	SYNTAX 	INTEGER {
		unmanaged-hosts(1),
		all-hosts(2)
	}
	MAX-ACCESS  read-write
	STATUS obsolete 
	DESCRIPTION
		"This object describes about the MPE Quarantine and Remediation scope.
		 The value 'unmanaged-hosts', indicates that the MPE interface port based
		 quarantine and remediation action is applicable only to the MPE server's
		 unmanaged host and the value 'all-hosts' indicate that the MPE interface
		 port based qarantine and remediation action is applicable to all the hosts,
		 independent of MPE server.
		 Default: unmanaged-hosts(1)
		 "
	::= { mpeConfigGrp 1 }

mpeThrottleTimeout OBJECT-TYPE
	SYNTAX 	INTEGER (5..300)
	MAX-ACCESS  read-write
	STATUS obsolete	
	DESCRIPTION 
		" This depicts the MPE throttling timeout in seconds.
		Default: 120"
	::= { mpeConfigGrp 2 }

mpeInstallConfigGrp  OBJECT IDENTIFIER ::= { mpeConfigGrp 3 }

mpeIpAddress  OBJECT-TYPE
	SYNTAX IpAddress	
	MAX-ACCESS  read-write 
	STATUS	current
	DESCRIPTION 
		"The ipaddress of the MPE server"
	::= { mpeInstallConfigGrp  1 }

mpeAnonymousPort OBJECT-TYPE
	SYNTAX INTEGER (1..65535)	
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"The Anonymous SSL port on MPE server
		 Default: 8443"
	::= { mpeInstallConfigGrp 2 }

mpeTrustedSSLPort OBJECT-TYPE
	SYNTAX INTEGER (1..65535)	
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"The Trusted SSL port on MPE server
		 Default: 8444"
	::= { mpeInstallConfigGrp 3 }

mpeePOCred  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(3..100))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"ePO credentials in the form of username:password"
	::= { mpeInstallConfigGrp 4 }

mpeAnonymousURI  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(10..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"URI of the MPE server which listens on Anonymous SSL port"
	::= { mpeInstallConfigGrp 5 }

mpeTrustedURI  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(10..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"URI of the MPE server which listens on Trusted SSL port"
	::= { mpeInstallConfigGrp 6 }

mpeInstallConfigAction  OBJECT-TYPE
	SYNTAX 	INTEGER {
		install(1),
		deinstall(2)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object describes about the possible MPE Install configuration actions."
	::= { mpeInstallConfigGrp 7 }

mpeInstallConfigStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
                installInProgress (1),
                installed (2),
		deinstallInProgress (3),
		deinstalled (4),
		certReqFailure(5),
		sSLError(6),
		httpRespError(7),
		mpeURIError(8),
		ePOCredError(9),
		mpeServerError(10),
		mpeTimeoutError(11)
	}
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
		"This describes the possible MPE install configuration states.
		 Default : deinstalled (4)"
	::= { mpeInstallConfigGrp 8 }

mpeRootCertStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		not-found(0),
		found(1)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		" This object informs whether the MPE Root Certificate file is present on the sensor."
	::= { mpeConfigGrp 4 }

mpeDeleteRootCert OBJECT-TYPE
	SYNTAX 	INTEGER {
		delete(1)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object is used to remove the MPE Root Certificate from the sensor. Deletion of the
		 MPE root certificate succeeds only when the MPE is not yet installed."
	::= { mpeConfigGrp 5 }

mnacHealthLevelListenPort OBJECT-TYPE
	SYNTAX INTEGER (1..65535)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION
		"This object is used to configure/retrieve the trusted health level message listen port
		 on the sensor, on which MNAC communication happens asynchronously.
		 Default: 8445"
	::= { mpeConfigGrp 6 }

mnacConnectivityFailureTimeout OBJECT-TYPE
	SYNTAX INTEGER (30..120)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION
		"This object is used to configure/retrieve the MNAC connectivity failure in seconds.
		Default: 32"
	::= { mpeConfigGrp 7 }

mnacAgentGUIDPort OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION
		"This object is used to configure/retrieve the agent GUID request listen port on the 
		MNAC Agent, to which the intrushield sensor would send the agent GUID request.
		Default: 8444"
	::= { mpeConfigGrp 8 }

mpeExcludedMacTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF MPEExcludedMacEntry
	MAX-ACCESS  not-accessible
	STATUS	obsolete
	DESCRIPTION 
		"
			
		"
	::= { mpeGrp 2 }

mpeExcludedMacEntry  OBJECT-TYPE
	SYNTAX 	MPEExcludedMacEntry
	MAX-ACCESS  not-accessible
	STATUS	obsolete
	DESCRIPTION 
		"Each entry specified is indexed by MAC Adress. 
		"
	INDEX { mpeMacAddress }
	::= { mpeExcludedMacTable 1 }

MPEExcludedMacEntry ::= SEQUENCE {
	mpeMacAddress
		MacAddress,
	mpeMacChangeAction
		RowStatus	
}

mpeMacAddress  OBJECT-TYPE
	SYNTAX MacAddress	
	MAX-ACCESS	not-accessible 
	STATUS	obsolete
	DESCRIPTION 
		"Mac address to be excluded from Mpe processing (Floater Mac)"
	::= { mpeExcludedMacEntry 1 }


mpeMacChangeAction  OBJECT-TYPE
	SYNTAX 	RowStatus 
	MAX-ACCESS  read-create
	STATUS  obsolete
	DESCRIPTION
		"This object used for user to add and delete rows in to the table."
	::= { mpeExcludedMacEntry 2 }

--
-- remediationGrp 
--

remediationGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 25 }

remediationConfigGrp  OBJECT IDENTIFIER ::= { remediationGrp  1 }

remediationTimeout OBJECT-TYPE
	SYNTAX 	INTEGER (15..60)
	MAX-ACCESS  read-write
	STATUS obsolete	
	DESCRIPTION 
		"Time in minutes for which the hosts needs to be quarantined so that it can be remediated.
		Default: 30"
	::= { remediationConfigGrp 2 }

-- ez (enforcement zone) Logging support on the Sensor

ezLogAlertGrp	OBJECT IDENTIFIER ::=  { ivSensorConfigurationMIB 26 }

ezAlertLogging	OBJECT-TYPE
	SYNTAX	INTEGER {
		g-enable-dropped (1),
		g-enable-allowed (2),
		g-enable-all (3),
		enable-per-acl (4),
		disable (5)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION   
 		"This object specifies various ways to enable EZ(enforcement zone) alert logging or disable it altogether.
		This is applicable on a sensor wide basis for all ports in inline mode.
		Default: disable (5)"
	::= { ezLogAlertGrp 1 }

ezAlertThrottleMaxIpPair OBJECT-TYPE
        SYNTAX  INTEGER (1..32)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Once this threshold is exceeded, sensor will only send one
                summary ez alert for all addresses (srcip's and destip's) that
                match the aclid/vidsid.
                Default: 10"
        ::= { ezLogAlertGrp 2 }

ezAlertThrottleInterval  OBJECT-TYPE
        SYNTAX  INTEGER (1..3600)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the enforcement zone alert throttle interval.
                Default: 120 seconds"
        ::= { ezLogAlertGrp 3 }


ezAlertThrottleAction  OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object can be used to enable and disable ez alert throttling.
                Default: enable(1)"
        ::= { ezLogAlertGrp 4 }

ezAlertThrottleThreshold  OBJECT-TYPE
        SYNTAX  INTEGER (1..25)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the number of alerts that
                need to be sent before sensor starts to throttle the ez alerts.
                For example if this value is 10, it will send the first 10
                ez alerts with the following key: aclid/vidsid/srcip/destip.
                This parameters will use the ezAlertThrottleInterval as the
                interval.
                Default: 5"
        ::= { ezLogAlertGrp 5 }

ezAlertDirectToSyslog  OBJECT-TYPE
        SYNTAX  INTEGER {
                sendViaNSM (1),
                sendDirect (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object can be used to enable sending EZ logs directly to syslog viewer instead of sending it via NSM.
         Default: sendViaNSM (1)"
        ::= { ezLogAlertGrp 6 }

nbadGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 27 }

nbadConfigGrp  OBJECT IDENTIFIER ::= { nbadGrp 1 }

nbadSensorIpAddress  OBJECT-TYPE
	SYNTAX IpAddress	
	MAX-ACCESS  read-write 
	STATUS	current
	DESCRIPTION 
		"The ipaddress of the NBAD server to which all the collected flowrecords would be sent."
	::= { nbadConfigGrp  1 }

nbadSensorPort OBJECT-TYPE
	SYNTAX INTEGER (1024..65535)	
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"The port on which the NBAD server is listening for flow records."
	::= { nbadConfigGrp 2 }

nbadIPSPriMonPortId OBJECT-TYPE
	SYNTAX TrellixPortLinearIndex
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"This object contains the primary IPS monitoring linear port index to be used 
		 to send flow records to the NBAD sensor."
	::= { nbadConfigGrp 3 }

nbadIPSSecMonPortId OBJECT-TYPE
	SYNTAX TrellixPortLinearIndex 	
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"This object contains the secondary IPS monitoring linear port index to be used 
		 to send flow records to the NBAD sensor. This monitoring port would be used
		 only when the configured primary monitoring port cannot be utilised to send
		 the flow records to the NBAD sensor."
	::= { nbadConfigGrp 4 }

nbadAppFingerPrintingEnabled OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object value if set to TRUE indicates that application finger printing is enabled.
		Default: False"
	::= { nbadConfigGrp 5 }

nbadOSFingerPrintingEnabled OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object value if set to TRUE indicates that OS finger printing is enabled.
		Default: False"
	::= { nbadConfigGrp 6 }

nbadSslFlowDataCaptureEnabled OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object value if set to TRUE indicates that ssl flow data capture is enabled.
		Default: False"
	::= { nbadConfigGrp 7 }

nbadFlowProtocolId OBJECT-TYPE
	SYNTAX	INTEGER {
		netflow (1)
	}
	MAX-ACCESS  read-write
	STATUS  current
        DESCRIPTION
                "This object value set indicates the protocol type of the exported flow records.
                Default: netflow (1)"
        ::= { nbadConfigGrp 8 }

nbadFlowProtocolVersion OBJECT-TYPE
	SYNTAX	INTEGER {
		netFlowVersion9 (1)
	}

	MAX-ACCESS  read-write
	STATUS  current
        DESCRIPTION
                "This object value set indicates the protocol version of the exported flow records.
		Default: netFlowVersion9 (1)"
        ::= { nbadConfigGrp 9 }

nbadCaptureTCP OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2)
        }

	MAX-ACCESS  read-write
	STATUS  current
        DESCRIPTION
                "This object value set indicates whether netflow capture for TCP flows is enabled or not.
                Default: enable (1)"
        ::= { nbadConfigGrp 10 }

nbadCaptureUDP OBJECT-TYPE
	SYNTAX	INTEGER {
		enable (1),
		disable (2)
	}

	MAX-ACCESS  read-write
	STATUS  current
        DESCRIPTION
                "This object value set indicates whether netflow capture for UDP flows is enabled or not.
                Default: enable (1)"
        ::= { nbadConfigGrp 11 }

nbadCaptureICMP OBJECT-TYPE
	SYNTAX	INTEGER {
		enable (1),
		disable (2)
	}

	MAX-ACCESS  read-write
	STATUS  current
        DESCRIPTION
                "This object value set indicates whether netflow capture for ICMP flows is enabled or not.
                Default: disable (2)"
        ::= { nbadConfigGrp 12 }

hostDataGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 28 }

hostDataTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF HostDataEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table containing entries for each discovered host. (indexed via hostDataIndex) 
		This table contains Trellix specific MIB objects.
		"
	::= { hostDataGrp 1 }

hostDataEntry  OBJECT-TYPE
	SYNTAX 	HostDataEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This MIB object contains all the columnar objects, 
		that describe the contents of each discovered host.
		Indexed by hostDataIndex"
	INDEX { hostDataIndex }
	::= { hostDataTable 1 }

HostDataEntry ::= SEQUENCE {
	hostDataIndex
		INTEGER,
	hostIPAddress
		IpAddress,
	hostMacAddress
		MacAddress,
    	hostDetectedDHCPMonPortId
        	TrellixPortLinearIndex,
	hostName
		DisplayString,
	hostUpdatedTimeStamp
		INTEGER,
	hostAgentGuid
		DisplayString,
	hostNACStatus
		INTEGER,
	hostState
		INTEGER,
	hostDeploymentMode
		INTEGER,
	hostHealthLevel
		INTEGER,
	hostEZId
		INTEGER,
	hostUserName	
		DisplayString,
	hostPolicyId
		INTEGER,
	hostDetectedTimeStamp
		INTEGER,
	hostOSInfo
		DisplayString,
	hostMNACAgentOSInfo
		DisplayString,
	hostActive
		TruthValue,
    	hostDetectedStdMonPortId
        	TrellixPortLinearIndex,
    	hostDetectionType
        	INTEGER,
	hostUserAuthProtocol
        	INTEGER,
	hostSwitchId
        	INTEGER,
	hostSwitchPortId
        	INTEGER,
	hostSwitchPortGroupId
        	INTEGER,
	hostQuarantineVlanId
        	INTEGER,
	hostProductionVlanId
        	INTEGER,
	nasIpAddress
		IpAddress,
	nasGroupObjectId
        	INTEGER,
	userGroupObjectId
        	INTEGER,
	deviceProfileString
		DisplayString,
	hostOperationalMode
        	INTEGER,
	hostEnforcementAction
        	INTEGER,
	flexiblePolicyRuleId
        	INTEGER
}

hostDataIndex OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The index of the Host Data Entry"
	::= { hostDataEntry 1 }

hostIPAddress  OBJECT-TYPE
	SYNTAX IpAddress	
	MAX-ACCESS  read-only 
	STATUS	current
	DESCRIPTION 
		"The ipaddress of the detected host."
	::= { hostDataEntry  2 }

hostMacAddress OBJECT-TYPE
	SYNTAX MacAddress	
	MAX-ACCESS  read-only 
	STATUS	current
	DESCRIPTION 
		"The MAC address of the detected host."
	::= { hostDataEntry  3 }

hostDetectedDHCPMonPortId OBJECT-TYPE
    	SYNTAX TrellixPortLinearIndex 
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"The monitoring interface linear port index over which the host was detected in DHCP mode."
    ::= { hostDataEntry 4 }

hostName OBJECT-TYPE
	SYNTAX DisplayString (SIZE(0..16))
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The name of the detected host."
	::= { hostDataEntry 5 }

hostUpdatedTimeStamp OBJECT-TYPE
        SYNTAX  INTEGER (0..4294967295)
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The time of the host getting updated last. This would be zero intilially 
		 at the time of host getting detected."
	::= { hostDataEntry 6 }

hostAgentGuid OBJECT-TYPE
	SYNTAX DisplayString (SIZE(0..16))
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The agent GUID of the detected host."
	::= { hostDataEntry 7 }

hostNACStatus OBJECT-TYPE
	SYNTAX INTEGER {
                managed (1),
                unmanaged (2),
                unmanageable (3),
                unknown (4)
        }
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The detected host NAC status."
	::= { hostDataEntry 8 }

hostState OBJECT-TYPE
        SYNTAX  INTEGER {
                preadmit-new (1),
                preadmit-sgap (2),
                preadmit-user-detect (3),
                preadmit-host-detect (4),
                preadmit-remediate (5),
                postadmit (6),
                postadmit-remediate (7),
                post-boot (8),
		ib-host-detect (9),
		ib-auth-wait (10),
		ib-host-sgap (11),
		ib-user-detect (12),
		ib-host-remediate (13),
		ib-host-admit (14),
		oob-host-admit (15),
		ib-host-offline (16)
        }
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The state of the detected host entry."
	::= { hostDataEntry 9 }

hostDeploymentMode OBJECT-TYPE
        SYNTAX  INTEGER {
                dhcp (1),
                standard (2),
                hybrid (3),
		oob (4)
        }
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"The deployment mode of the detected host."
    ::= { hostDataEntry 10 }

hostHealthLevel OBJECT-TYPE
        SYNTAX  INTEGER (1..6)
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The health level of the detected host."
	::= { hostDataEntry 11 }

hostEZId OBJECT-TYPE
        SYNTAX  INTEGER
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The applied enforcement zone id for the detected host."
	::= { hostDataEntry 12 }
	
hostUserName OBJECT-TYPE
	SYNTAX DisplayString (SIZE(0..255))
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The IBAC username of the detected host."
	::= { hostDataEntry 13 }

hostPolicyId OBJECT-TYPE
        SYNTAX  INTEGER
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The IBAC policy id of the detected host."
	::= { hostDataEntry 14 }

hostDetectedTimeStamp OBJECT-TYPE
        SYNTAX  INTEGER (0..4294967295)
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The time of the host getting detected."
	::= { hostDataEntry 15 }
		
hostOSInfo OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The Operation system information of the detected host."
	::= { hostDataEntry 16 }

hostMNACAgentOSInfo OBJECT-TYPE
	SYNTAX DisplayString (SIZE(0..8))
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The OS information of the detected host provided by the MNAC agent."
	::= { hostDataEntry 17 }

hostActive OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Indicates whether the host is Active or not. If set to true, it indicates the host is active"
	::= { hostDataEntry 18 }

hostDetectedStdMonPortId OBJECT-TYPE
    	SYNTAX TrellixPortLinearIndex 
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"The monitoring interface linear port index over which the host was detected in Standard mode."
    ::= { hostDataEntry 19 }

hostDetectionType OBJECT-TYPE
        SYNTAX  INTEGER {
		other (0),
                l2 (1),
                l3 (2),
                vpn (3),
		snmp (4),
		radiusMac (5),
		radius8021x (6),
                l3-snmp(7),
                l3-radiusMac(8),
                l3-radius8021x(9)
        }
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"The detection type of the detected host. For OOB cases, this includes the discovery mechanism as well."
    ::= { hostDataEntry 20 }

hostUserAuthProtocol OBJECT-TYPE
        SYNTAX  INTEGER {
		authGuest (0),
                authRadius (1),
                authAD (2),
                authSelfReg (3),
		authADSGAP (4),
		auth8021xRadius (5)
        }
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"Authentication type of the logged in IBAC user."
    ::= { hostDataEntry 21 }

hostSwitchId OBJECT-TYPE
        SYNTAX  INTEGER
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"Switch instance ID on which host was detected in OOB mode."
    ::= { hostDataEntry 22 }

hostSwitchPortId OBJECT-TYPE
        SYNTAX  INTEGER
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"Switch port ID on which host was detected in OOB mode"
    ::= { hostDataEntry 23 }

hostSwitchPortGroupId OBJECT-TYPE
        SYNTAX  INTEGER
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"Switch port group ID on which host was detected in OOB mode"
    ::= { hostDataEntry 24 }

hostQuarantineVlanId OBJECT-TYPE
        SYNTAX  INTEGER
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
		"Quarantine VLAN Id corresponding to the host which was detected in OOB mode."
    ::= { hostDataEntry 25 }

hostProductionVlanId OBJECT-TYPE
        SYNTAX  INTEGER
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"Production VLAN Id corresponding to the host which was detected in OOB mode."
    ::= { hostDataEntry 26 }

nasIpAddress  OBJECT-TYPE
	SYNTAX IpAddress	
	MAX-ACCESS  read-only 
	STATUS	current
	DESCRIPTION 
		"The Network Server Access Ipaddress of the switch where the host is connecting to."
	::= { hostDataEntry  27 }

nasGroupObjectId OBJECT-TYPE
        SYNTAX  INTEGER
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"Flexible policy Network Server Access Group Object Id for the host."
    ::= { hostDataEntry 28 }

userGroupObjectId OBJECT-TYPE
        SYNTAX  INTEGER
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"Flexible policy User Group Object Id for the host."
    ::= { hostDataEntry 29 }


deviceProfileString OBJECT-TYPE
	SYNTAX DisplayString (SIZE(0..128))
	MAX-ACCESS read-only 
	STATUS	current
	DESCRIPTION 
		"The device profile string provided by the third party device profiling ldap server for the host."
	::= { hostDataEntry 30 }

hostOperationalMode OBJECT-TYPE
        SYNTAX  INTEGER {
		enforcement (1),
                audit (2),
                simulation (3)
        }
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"This object indicates the operational mode for the host."
    ::= { hostDataEntry 31 }

hostEnforcementAction OBJECT-TYPE
        SYNTAX  INTEGER {
		deny (1),
                allow (2),
                custom-enforce (3)
        }
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"This object indicates the kind of enforcement done for the host."
    ::= { hostDataEntry 32 }

flexiblePolicyRuleId OBJECT-TYPE
        SYNTAX  INTEGER
    	MAX-ACCESS read-only
    	STATUS  current
    	DESCRIPTION
        	"This indicates the flexible policy rule for the host."
    ::= { hostDataEntry 33 }

hostConfigGrp OBJECT IDENTIFIER ::= {  hostDataGrp 2 }

hostEntryAttribute OBJECT-TYPE
        SYNTAX  INTEGER {
                ip (1),
                mac (2)
        }
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"Host entry attribute to be considered for config action."
	::= { hostConfigGrp 1 }

hostEntryIpAddress OBJECT-TYPE
	SYNTAX IpAddress	
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"Host entry Ip address to be considered for config action."
	::= { hostConfigGrp 2 }

hostEntryMac OBJECT-TYPE
	SYNTAX MacAddress	
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"Host entry Mac address to be considered for config action."
	::= { hostConfigGrp 3 }

hostEntryConfig OBJECT-TYPE
        SYNTAX  INTEGER {
                delete-host (1),
		modify-naz (2),
                revert-naz (3),
		host-oob-to-inline (4),
		host-inline-to-oob (5)
        }
	MAX-ACCESS read-write
	STATUS	current
	DESCRIPTION
		"Host entry config action."
	::= { hostConfigGrp 4 }

hostEntryEZId OBJECT-TYPE
        SYNTAX  INTEGER
	MAX-ACCESS read-write
	STATUS	current
	DESCRIPTION 
		"EZ-ID to be considered for modifying the NAZ of the given host entry."
	::= { hostConfigGrp 5 }

hostDataAvailabilityStatus OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object indicates the availability of the hostData through SNMP. This information
                 is useful immediately after the sensor reboot, as the Host Data even if
                 present on the sensor would be available through SNMP only after the
                 system health becomes GOOD, as the host data would be initialised only
                 during the initial sigfile processing.
                 True: Host Data available after the sensor initialisation or no persisted hostdata.
                 False: In other scenarios. "
        ::= { hostDataGrp 3 }
 
--This group contains MIB objects related to SGAP Configuration

sgapGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 29 }

sgapConfigGrp  OBJECT IDENTIFIER ::= { sgapGrp 1 }

sgapAuthTimeout OBJECT-TYPE
  SYNTAX  INTEGER (10..600)
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
    "Authentication channel timeout in seconds.
    Default: 30"
  ::= { sgapConfigGrp 1 }

sgapCSRConfigGrp OBJECT IDENTIFIER ::= { sgapConfigGrp 2 }

sgapCSRCountryName  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(1..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Country name for generating the CSR. Use the two-letter code
		without punctuation for country like US or CA."
	::= { sgapCSRConfigGrp 1 }

sgapCSRStateProvince  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(1..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"State or Province name for generating the CSR. Spell out the
		state completely."
	::= { sgapCSRConfigGrp 2 }

sgapCSRLocality  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(1..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"City or town name for generating the CSR."
	::= { sgapCSRConfigGrp 3 }

sgapCSRCompany  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(1..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Company name for generating the CSR. If the company name has
		symbols, spell out the symbol or omit it to enroll."
	::= { sgapCSRConfigGrp 4 }

sgapCSROrganizationalUnit  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(1..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The organizational unit is the name of the department or organization unit
		making the request. This is an optional field"
	::= { sgapCSRConfigGrp 5 }

sgapCSRCommonName  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(1..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The common name is the host plus domain name. It looks like
		www.company.com or company.com."
	::= { sgapCSRConfigGrp 6 }

sgapCSRGenerateAction  OBJECT-TYPE
	SYNTAX 	INTEGER {
		other(0),
		generateCSR(1),
    generateSelfSigned(2)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This action is used to generate the CSR/self signed certificate.
		 Default : other (0)"
	::= { sgapCSRConfigGrp 7 }

sgapCSRGenerateStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		    other (0),
                generationInProgress (1),
                generationComplete (2),
		    generationFailed (3)
	}
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
		"This object describes the possible CSR generation states.
		 Default : other (0)"
	::= { sgapCSRConfigGrp 8 }

sgapCertStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		    other (0),
        certAbsent (1),
        defaultCert (2),
        selfsignedCert (3),
        casignedCert (4)
	}
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
    "This object indicates the sgap cert status on the sensor.
    Default: 0"
  ::= { sgapConfigGrp 3 }

--
-- This group contains MIB objects related to threshold alarm and historical trends related configuration
--

alarmAndTrendsGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 30 }

sensorPerfAlertGrp  OBJECT IDENTIFIER ::= { alarmAndTrendsGrp  1 }

sensorPerfAlertEnable  OBJECT-TYPE
	SYNTAX 	TruthValue 
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object is used to enable/disable generation of sensor performance alerts,
		for the purpose of historical trends.
                Default: false(2)"
	::= { sensorPerfAlertGrp 1 }

sensorPerfAlertDuration  OBJECT-TYPE
	SYNTAX INTEGER (1..60) 
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"This object is used to configure the duration of sensor performance alerts in minutes,
		for the purpose of historical trends.
                Default: 5"
	::= { sensorPerfAlertGrp 2 }

sensorPerfAlertParameters  OBJECT-TYPE
	SYNTAX OCTET STRING
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
		"This object is used to configure the parameters of sensor performance alerts,
		for the purpose of historical trends. The parameter bit positions are as given below.
		msb-bit(1) : cpu-utilization,
		msb-bit(2) : tcpudp-flows,
		msb-bit(3) : sensor-throughput,
		msb-bit(4) : mon-port-data-rate,
                msb-bit(5) : reserved
                msb-bit(6) : reserved
                msb-bit(7) : system-memory,
                msb-bit(8) : packet-buffers,
                msb-bit(9) : decrypted-ssl-flows"
	::= { sensorPerfAlertGrp 3 }

alarmConfigGrp OBJECT IDENTIFIER ::= { alarmAndTrendsGrp  2 }

alarmStatus  OBJECT-TYPE
	SYNTAX 	TruthValue 
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object is used to enable/disable generation of threshold based alarms.
                Default: false(2)"
	::= { alarmConfigGrp 1 }

alarmDeleteAllEntries OBJECT-TYPE
	SYNTAX 	INTEGER {
		true(1)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object is used to delete all alarm entries in a single operation."
	::= { alarmConfigGrp 2 }

alarmDuration OBJECT-TYPE
	SYNTAX INTEGER (1..60)
	MAX-ACCESS read-write
	STATUS	current
	DESCRIPTION
		"This object indicates the duration in minutes, at which the sensor needs to perform
		threshold checks and if required generate the specific alarm.
		Default : 1"
	::= { alarmConfigGrp 3 }

alarmTable OBJECT-TYPE
	SYNTAX SEQUENCE OF AlarmEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"Table containing entries for configured threshold based alarms. (indexed via alarmIndex) 
		This table contains Trellix specific MIB objects.
		"
	::= { alarmConfigGrp 4 }

alarmEntry  OBJECT-TYPE
	SYNTAX 	AlarmEntry
	MAX-ACCESS  not-accessible
	STATUS	current
	DESCRIPTION 
		"This MIB object contains all the columnar objects, 
		that describe the contents of each threshold based alarm.
		Indexed by alarmIndex"
	INDEX { alarmIndex }
	::= { alarmTable 1 }

AlarmEntry ::= SEQUENCE {
	alarmIndex
		INTEGER,
	alarmSampleType
		INTEGER,
	alarmSampleTypeIndexBitmap
		OCTET STRING,
	alarmSampleTypeDesc
		DisplayString,
    	alarmRaisingThreshold
        	Unsigned32,
	alarmFallingThreshold
		Unsigned32,
	alarmStartupType
		INTEGER,
	alarmEntryStatus
		RowStatus
}

alarmIndex OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS not-accessible 
	STATUS	current
	DESCRIPTION 
		"The index of the threshold based alarm entry"
	::= { alarmEntry 1 }

alarmSampleType OBJECT-TYPE
	SYNTAX INTEGER
	{
		cpu-utilization-abs (0),
                tcpudp-flows (1),
		sensor-throughput-delta (2),
		mon-port-throughput-delta (3),
		sensor-l2-error-drop-delta (4),
		sensor-l3-l4-error-drop-delta (5),
                system-memory (6),
                packet-buffers (7),
                decrypted-ssl-flows (8)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
		"This object indicates the alarm sample type for which the sensor needs to generate alarms
		based on alarm threshold settings. The threshold value range vary based on the sample types :
		cpu-utilization-abs : 0 - 100,
                tcpudp-flows : 0 - 100,
		sensor-throughput-delta : 0 - 100,
		mon-port-throughput-delta : 0 - 100, 
		l2-error-drop-delta : 0 - 4294967295,
		l3-l4-error-drop-delta : 0 - 4294967295,
                system-memory : 0 - 100,
                packet-buffers : 0 - 100,
                decrypted-ssl-flows : 0 - 100
 		"
	::= { alarmEntry 2 }

alarmSampleTypeIndexBitmap  OBJECT-TYPE
	SYNTAX OCTET STRING (SIZE (1..16))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object provides the index bit map for the alarm sample type id. The bit
		setting would be similar to the BITS type and in network order. The bitmap would be as
		given below :
			cpu-utilization-abs - 0,
			sensor-throughput-delta - 0,
			mon-port-throughput-delta - Bit position indicates the <linear portIndex> 
			sensor-l2-error-drop-delta - 0,
			sensor-l3-l4-error-drop-delta - 0 
		"
	::= { alarmEntry 3 }

alarmSampleTypeDesc OBJECT-TYPE
	SYNTAX DisplayString (SIZE(1..32))
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object provides the alarm sample type description such as 'lower-band', 'higher-band', etc."
	::= { alarmEntry 4 }

alarmRaisingThreshold OBJECT-TYPE
	SYNTAX Unsigned32
	MAX-ACCESS read-write
	STATUS	current
	DESCRIPTION
		"This object indicates the raising threshold value. The sensor would generate raising
		threshold alarm when the sample type counter exceeds this value."
	::= { alarmEntry 5 }

alarmFallingThreshold OBJECT-TYPE
	SYNTAX Unsigned32
	MAX-ACCESS read-write
	STATUS	current
	DESCRIPTION
		"This object indicates the falling threshold value. The sensor would generate falling
		threshold alarm when the sample type counter reduces below this value."
	::= { alarmEntry 6 }

alarmStartupType OBJECT-TYPE
	SYNTAX INTEGER {
		raising (1),
                falling (2),
		both (3)
                }
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"This object indicates the first alarm type that the sensor must generate before 
		generating the other threshold based alarm. For eg; if the value is set to 'raising (1)',
		then the sensor has to first raise an alarm based on raising threshold value and only 
		then based on falling threshold value.
		Default : raising (1)"
	::= { alarmEntry 7 }

alarmEntryStatus OBJECT-TYPE
	SYNTAX RowStatus
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"This object is used to create a new threshold based alarm."
	::= { alarmEntry 8 }


bwSavingStatus OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to enable/disable bandwidth saving.
                Default: false(2)"
        ::= { alarmConfigGrp 5 }
	

--
-- This group contains MIB objects applicable to NAC-only Appliances.
--

oobnacGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 31 }
-- Support for oobnacGrp is deprecated in V-series sensors(VmIPS).
-- This group consists of scalars for pre-discovery phase and swInstanceTable(based on switch ID).
oobnacSwDiscoveryGrp  OBJECT IDENTIFIER ::= { oobnacGrp 1 }

-- This table creates an entry for the switch (indexed based on switch id ).

swInstanceTable       OBJECT-TYPE
                      SYNTAX SEQUENCE OF SwInstanceEntry
                      MAX-ACCESS  not-accessible
                      STATUS  current
                      DESCRIPTION
                        "Table containing entries for each switch instance(indexed via switch id)."
                ::= { oobnacSwDiscoveryGrp 1 }

swInstanceEntry       OBJECT-TYPE
                      SYNTAX  SwInstanceEntry
                      MAX-ACCESS  not-accessible
                      STATUS  current
                      DESCRIPTION
                        "This MIB object contains all the attributes that are specific to the switch instance. Indexed by swIdIndex"
                      INDEX { swIdIndex }
                ::= { swInstanceTable 1 }

SwInstanceEntry ::= SEQUENCE {
                swIdIndex
                        INTEGER,
                swDetDesc
                        DisplayString,
                swProfileId
                        INTEGER,
                swIPAddress
                        IpAddress,
                swIPV6Address
                        Ipv6Address,
		swName
			DisplayString,
                swDesc
                        DisplayString,
                swEnable
                        TruthValue,
                swSNMPsupport
                        TruthValue,
                swSnmpVerSupport
                        INTEGER,
                swREADCommunityStr
                        DisplayString,
                swWRITECommunityStr
                        DisplayString,
                swTRAPCommunityStr
                        DisplayString,
                swSNMPPort
                        INTEGER,
                swV3UserName
                        DisplayString,
                swV3SecurityLevel
                        INTEGER,
                swV3AuthProtocol
                        INTEGER,
                swV3AuthKey
                        DisplayString,
                swV3EncrProtocol
                        INTEGER,
                swV3EncrKey
                        DisplayString,
                swCLIsupport
                        TruthValue,
                swCLINwProtocol
                        INTEGER,
                swCLIUserName
                        DisplayString,
                swCLIPwd
                        DisplayString,
                swCLIEnablePwd
                        DisplayString,
                swCLIAutoSaveConfig
                        TruthValue,
                swRadiusSupport
                        TruthValue,
                swRadiusSharedSecret
                        DisplayString,
                swPlaceHolderVlan
                        DisplayString,
                swUseDefaultQVlanPool
                        TruthValue,
                swQVlanPoolRange
                        DisplayString,
                swDiscoverAction
                        RowStatus,
		swCLILoginType
                        INTEGER,
	 	swAuthMacAddRadSrvOption
                        TruthValue,
                swActionStatus
                        INTEGER,
                swPortDefaultVlan
                        INTEGER,
                swActionStatusTime
                        INTEGER


}

swIdIndex             OBJECT-TYPE
                      SYNTAX     INTEGER
                      MAX-ACCESS not-accessible
                      STATUS     current
                      DESCRIPTION
                        "The index"
                ::= { swInstanceEntry 1 }

swDetDesc             OBJECT-TYPE
                      SYNTAX          DisplayString(SIZE(0..256))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Description  returned by the switch. "
                ::= { swInstanceEntry 2 }

swProfileId           OBJECT-TYPE
                      SYNTAX          INTEGER
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "switch profile id returned by the switch."
                ::= { swInstanceEntry 3 }

swIPAddress           OBJECT-TYPE
                      SYNTAX          IpAddress
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "IP address of the switch instance sent down from ISM when a new switch is being added."
                ::= { swInstanceEntry 4 }

swIPV6Address         OBJECT-TYPE
                      SYNTAX          Ipv6Address
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "IPV6 address of the switch instance sent down from ISM when a new switch is being added."
                ::= { swInstanceEntry 5 }

swName                OBJECT-TYPE
                      SYNTAX          DisplayString(SIZE(0..256))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Switch name returned by the switch."
                  ::= { swInstanceEntry 6 }



swDesc                OBJECT-TYPE
                      SYNTAX          DisplayString(SIZE(0..256))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Switch name returned by the switch. This can be modified by ISM."
                ::= { swInstanceEntry 7 }

swEnable              OBJECT-TYPE
                      SYNTAX          TruthValue
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Option to enable/disable the specific switch upon discovery. The default value is enable(1)."
                ::= { swInstanceEntry 8 }

swSNMPsupport         OBJECT-TYPE
                      SYNTAX          TruthValue
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Support for snmp communication between sensor and the switch.Currently the value always remains true."
                ::= { swInstanceEntry 9 }

swSnmpVerSupport      OBJECT-TYPE
                      SYNTAX         INTEGER {
                        snmpv1(1),
                        snmpv2(2),
                        snmpv3(3)
                      }
                      MAX-ACCESS     read-write
                      STATUS         current
                      DESCRIPTION
                        "snmp version supported by the switch. The default will be version 2."
                ::= { swInstanceEntry 10 }

swREADCommunityStr    OBJECT-TYPE
                      SYNTAX       DisplayString (SIZE(0..80))
                      MAX-ACCESS   read-write
                      STATUS       current
                      DESCRIPTION
                        "String used for all read-only snmp data communication between sensor and the switch. The default string is public."
                ::= { swInstanceEntry 11 }

swWRITECommunityStr   OBJECT-TYPE
                      SYNTAX       DisplayString (SIZE(0..80))
                      MAX-ACCESS   read-write
                      STATUS       current
                      DESCRIPTION
                        "String used for all read-write snmp data communication between sensor and the switch."
                ::= { swInstanceEntry 12 }

swTRAPCommunityStr    OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "community string used for the all the traps received from the switch."
                ::= { swInstanceEntry 13 }


swSNMPPort            OBJECT-TYPE
                      SYNTAX          INTEGER
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "snmp port for snmp communication with the switch(161)."
                ::= { swInstanceEntry 14 }


swV3UserName          OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..31))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "User name for snmp v3 communication."
                ::= { swInstanceEntry 15 }

swV3SecurityLevel     OBJECT-TYPE
                      SYNTAX          INTEGER {
                                noAuthNoPriv(1),
                                authNoPriv(2),
                                authPriv(3)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Level of security supported by the switch. The default value is authPriv(3)."
                ::= { swInstanceEntry 16 }

swV3AuthProtocol      OBJECT-TYPE
                      SYNTAX          INTEGER {
                                mD5(1),
                                sHA(2)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "protocol for authentication of the user. The default value is Md5(1)."
                ::= { swInstanceEntry 17 }

swV3AuthKey           OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..15))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Key for authentication of the user."
                ::= { swInstanceEntry 18 }

swV3EncrProtocol      OBJECT-TYPE
                      SYNTAX          INTEGER {
                                dES(1),
                                aES(2)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "protocol for encryption of snmp communication messages. The default value is DES(1)."
                ::= { swInstanceEntry 19 }
swV3EncrKey           OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..15))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "key for encryting messages."
                ::= { swInstanceEntry 20 }

swCLIsupport          OBJECT-TYPE
                      SYNTAX          TruthValue
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Support for CLI communication between sensor and the switch."
                ::= { swInstanceEntry 21 }

swCLINwProtocol       OBJECT-TYPE
                      SYNTAX          INTEGER {
                                telnet(1),
                                ssh(2)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "support for a command line interfaces network protocol such as TELNET or ssh. Default value is telnet(1)."
                ::= { swInstanceEntry 22 }

swCLIUserName         OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "user name for CLI communication."
                ::= { swInstanceEntry 23 }

swCLIPwd              OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "password to authenticate CLI user."
                ::= { swInstanceEntry 24 }

swCLIEnablePwd        OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Enable password to authenticate CLI user."
                ::= { swInstanceEntry 25 }

swCLIAutoSaveConfig   OBJECT-TYPE
                      SYNTAX  TruthValue
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                            "If this option is enabled then auto save CLI  configuration changes to flash."
                ::= { swInstanceEntry 26 }

swRadiusSupport       OBJECT-TYPE
                      SYNTAX          TruthValue
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Support for radius communication between sensor and the switch. The default value is enable(1)."
                ::= { swInstanceEntry 27 }

swRadiusSharedSecret  OBJECT-TYPE
                      SYNTAX       DisplayString (SIZE(0..80))
                      MAX-ACCESS   read-write
                      STATUS       current
                      DESCRIPTION
                        "A case-sensitive text string used to validate communications between two radius devices."
                ::= { swInstanceEntry 28 }

swPlaceHolderVlan     OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                                "special vlan value used for assigning qvlan value to an empty port."
                ::= { swInstanceEntry 29 }

swUseDefaultQVlanPool OBJECT-TYPE
                      SYNTAX          TruthValue
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Option to use globally set qvlan pool range."
                ::= { swInstanceEntry 30 }

swQVlanPoolRange      OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..30))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                                "Qvlan pool range assigned for the switch instance."
                ::= { swInstanceEntry 31 }

swDiscoverAction      OBJECT-TYPE
                      SYNTAX  RowStatus
                      MAX-ACCESS      read-create
                      STATUS          current
                      DESCRIPTION
                                "This action data will add a switch entry in the table. Default action is createAndGo(4)."
                ::= { swInstanceEntry 32 }


swCLILoginType	      OBJECT-TYPE
                      SYNTAX          INTEGER {
                                userPwd(1),
                                pwdEnable(2),
                                userPwdEnable(3)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Different login types supported for CLI. "
                ::= { swInstanceEntry 33 }

swAuthMacAddRadSrvOption       OBJECT-TYPE
                      SYNTAX          TruthValue
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Support for option to authenticate MAC addresses against radius server.Default option is to disabled(0)."
                ::= { swInstanceEntry 34 }


swActionStatus        OBJECT-TYPE
                      SYNTAX          INTEGER {
                                active(1),
                                inactive(2),
                                in-deletion-mode(3),
                                in-addition-mode(4)
                      }
                      MAX-ACCESS      read-only
                      STATUS          current
                      DESCRIPTION
                        "Variable to poll the status of the switch(in case sw goes down). "
                ::= { swInstanceEntry 35 }


swPortDefaultVlan     OBJECT-TYPE
                      SYNTAX          INTEGER
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Variable used for updating port default vlan for universal control point (UCP)switches. For non-ucp switches the value will default to zero."
                ::= { swInstanceEntry 36 }


swActionStatusTime    OBJECT-TYPE
                      SYNTAX  INTEGER (0..4294967295)
                      MAX-ACCESS  read-only
                      STATUS  current
                      DESCRIPTION
                        "Time when swActionStatus variable was updated."
                ::= { swInstanceEntry 37 }








--Scalar for the pre-discovery phase. No entry is created for the switch during this time.
-- Also scalars for switch snmp/cli test.

swIpAddress           OBJECT-TYPE
                      SYNTAX      IpAddress
                      MAX-ACCESS  read-write
                      STATUS      current
                      DESCRIPTION
                        "IP address of the switch instance sent down from ISM when a new switch is being added."
                ::= { oobnacSwDiscoveryGrp 2 }

swIpV6Address          OBJECT-TYPE
                      SYNTAX          Ipv6Address
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "IPV6 address of the switch instance sent down from ISM when a new switch is being added."
                ::= { oobnacSwDiscoveryGrp 3 }

readCommunityString   OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "This string is used for all read-only snmp data communication between sensor and the switch. The default string is public."
                ::= { oobnacSwDiscoveryGrp 4 }

snmpPort              OBJECT-TYPE
                      SYNTAX          INTEGER
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "The default port on which snmp runs(161)."
                ::= { oobnacSwDiscoveryGrp 5 }

snmpVerSupport        OBJECT-TYPE
                      SYNTAX         INTEGER {
                        snmpv1(1),
                        snmpv2(2),
                        snmpv3(3)
                      }
                      MAX-ACCESS     read-write
                      STATUS         current
                      DESCRIPTION
                        "snmp version supported by the switch. The default will be version 2."
                ::= { oobnacSwDiscoveryGrp 6 }

writeCommunityStr     OBJECT-TYPE
                      SYNTAX       DisplayString (SIZE(0..80))
                      MAX-ACCESS   read-write
                      STATUS       current
                      DESCRIPTION
                        "String used for all read-write snmp data communication between sensor and the switch."
                ::= { oobnacSwDiscoveryGrp 7 }

trapCommunityStr      OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "community string used for the all the traps received from the switch."
                ::= { oobnacSwDiscoveryGrp 8}


v3UserName            OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..31))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "User name for snmp v3 communication."
                ::= { oobnacSwDiscoveryGrp 9 }

v3SecurityLevel       OBJECT-TYPE
                      SYNTAX          INTEGER {
                                noAuthNoPriv(1),
                                authNoPriv(2),
                                authPriv(3)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Level of security supported by the switch. The default value is authPriv(3)."
                ::= { oobnacSwDiscoveryGrp 10 }

v3AuthProtocol        OBJECT-TYPE
                      SYNTAX          INTEGER {
                                mD5(1),
                                sHA(2)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "protocol for authentication of the user. The default value is Md5(1)."
                ::= { oobnacSwDiscoveryGrp 11 }

v3AuthKey             OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..15))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Key for authentication of the user."
                ::= { oobnacSwDiscoveryGrp 12 }

v3EncrProtocol        OBJECT-TYPE
                      SYNTAX          INTEGER {
                                dES(1),
                                aES(2)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "protocol for encryption of snmp communication messages. The default value is DES(1)."
                ::= { oobnacSwDiscoveryGrp 13 }

v3EncrKey             OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..15))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "key for encryting messages."
                ::= { oobnacSwDiscoveryGrp 14 }

cliNwProtocol         OBJECT-TYPE
                      SYNTAX          INTEGER {
                                telnet(1),
                                ssh(2)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "support for a command line interfaces network protocol such as TELNET or ssh. Default value is telnet(1)."
                ::= { oobnacSwDiscoveryGrp 15 }

cliUserName           OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "user name for CLI communication."
                ::= { oobnacSwDiscoveryGrp 16}


cliPwd                OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "password to authenticate CLI user."
                ::= { oobnacSwDiscoveryGrp 17 }

cliEnablePwd          OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..80))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Enable password to authenticate CLI user."
                ::= { oobnacSwDiscoveryGrp 18 }

swQueryAction         OBJECT-TYPE
                      SYNTAX  INTEGER {
                          initialQuery(1),
                          testSnmp(2),
                          testCli(3),
                          deleteAllSwEntries(4),
                          reLearnSwitch(5)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "action to get preliminary data (like sys uptime, sys description etc) from the switch. also to test cli and snmp."
                ::= { oobnacSwDiscoveryGrp 19}


cliLoginType        OBJECT-TYPE
                      SYNTAX          INTEGER {
                                userPwd(1),
                                pwdEnable(2),
                                userPwdEnable(3)
                      }
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "Different login types supported for CLI. "
                ::= { oobnacSwDiscoveryGrp 20 }

profileId             OBJECT-TYPE
                      SYNTAX          INTEGER
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "switch profile id returned by the switch."
                ::= { oobnacSwDiscoveryGrp 21 }

switchId              OBJECT-TYPE
                      SYNTAX     INTEGER
                      MAX-ACCESS read-write
                      STATUS     current
                      DESCRIPTION
                        "The sw global id used to re-learn the switch."
                ::= { oobnacSwDiscoveryGrp 22 }









-- This group consists of scalars applicable to all switches.
oobnacAllSwitchesGrp  OBJECT IDENTIFIER ::= { oobnacGrp 2 }


oobnDefaultQvlanPool  OBJECT-TYPE
                      SYNTAX          DisplayString (SIZE(0..30))
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                                "default qvlan pool range assigned for the all switches using default qvlan pool."

                ::= { oobnacAllSwitchesGrp 1 }


oobnacRadNumRetries   OBJECT-TYPE
                      SYNTAX          INTEGER
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "The default number of retries(3) allowed for radius users."
                ::= { oobnacAllSwitchesGrp 2 }


oobnacRadRespTimeOut  OBJECT-TYPE
                      SYNTAX          INTEGER
                      MAX-ACCESS      read-write
                      STATUS          current
                      DESCRIPTION
                        "The default timeout value(3 seconds) for radius response timeout."
                ::= { oobnacAllSwitchesGrp 3 }



--
-- OOB NAC Failover Group
--
--This group contains objects that identify the OOB NAC failover configuration information 
--

oobnacFailoverGrp  OBJECT IDENTIFIER ::= { oobnacGrp 3 }

oobnacFloatingIpAddress  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Floating Management Port IP Address."
	::= { oobnacFailoverGrp 1 }

oobnacFloatingIpv6Address  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Floating Management Port IPv6 Address."
	::= { oobnacFailoverGrp 2 }

oobnacFloatingNetMask  OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Floating Management Port Network mask as a IPAddress prefix."
	::= { oobnacFailoverGrp 3 }

oobnacFloatingv6NetMask  OBJECT-TYPE
	SYNTAX 	INTEGER
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Floating Management Port IPv6 Network mask as a IPAddress prefix."
	::= { oobnacFailoverGrp 4 }

oobnacFloatingGatewayIpAddress  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Floating Management Port Gateway IP Address."
	::= { oobnacFailoverGrp 5 }

oobnacFloatingGatewayIpv6Address  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Floating Management Port Gateway IP Address."
	::= { oobnacFailoverGrp 6 }

oobnacPeerIpAddress  OBJECT-TYPE
	SYNTAX 	IpAddress
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Failover Peer Management Port IP Address."
	::= { oobnacFailoverGrp 7 }

oobnacPeerIpv6Address  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-write  
	STATUS	current
	DESCRIPTION 
		"Failover Peer Management Port IPv6 Address."
	::= { oobnacFailoverGrp 8 }

oobnacFailoverSensorStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		standalone (0),
		standby (1),
		active (2)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"Status of the sensor in OOBNac failover."
	::= { oobnacFailoverGrp 9 }

--
-- This group contains Malware related MIB objects. These are applicable to
-- all M-series except NAC-only appliances.
--


malwareGrp     OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 32 }

-- Support for malwarePriDNSServerIp is now deprecated in sensors using new MIB.
malwarePriDNSServerIp   OBJECT-TYPE
                        SYNTAX          IpAddress
                        MAX-ACCESS      read-write
                        STATUS          obsolete
                        DESCRIPTION
                                "IP address of the primary DNS server."
        ::= { malwareGrp 1 }

-- Support for malwareSecDNSServerIp is now deprecated in sensors using new MIB.
malwareSecDNSServerIp   OBJECT-TYPE
                        SYNTAX          IpAddress
                        MAX-ACCESS      read-write
                        STATUS          obsolete
                        DESCRIPTION
                                "IP address of the secondary DNS server."
        ::= { malwareGrp 2 }

-- Support for malwarePriDNSServerIpV6 is now deprecated in sensors using new MIB.
malwarePriDNSServerIpV6 OBJECT-TYPE
                        SYNTAX          Ipv6Address
                        MAX-ACCESS      read-write
                        STATUS          obsolete
                        DESCRIPTION
                                "IPV6 address of the primary DNS server."
        ::= { malwareGrp 3 }

-- Support for malwareSecDNSServerIpV6 is now deprecated in sensors using new MIB.
malwareSecDNSServerIpV6 OBJECT-TYPE
                        SYNTAX          Ipv6Address
                        MAX-ACCESS      read-write
                        STATUS          obsolete
                        DESCRIPTION
                                "IPV6 address of the secondary DNS server."
        ::= { malwareGrp 4 }

malwareRiskLevel        OBJECT-TYPE
                        SYNTAX          INTEGER {
                                veryLow(1),
                                low(2),
                                medium(3),
                                high(4),
                                veryHigh(5)
                        }
                        MAX-ACCESS      read-write
                        STATUS          current
                        DESCRIPTION
                                " Malware risk level threshold value set by the user. The default level is Very Low."
        ::= { malwareGrp 5 }

-- Support for malwareArtemisDetectionMode is deprecated in sensors using new MIB.
malwareArtemisDetectionMode    OBJECT-TYPE
                        SYNTAX          INTEGER {
                                alertOnly(1),
                                alertAndBlock(2),
				alertBlockAndTCP-Reset(3)
                        }
                        MAX-ACCESS      read-write
                        STATUS          current
                        DESCRIPTION
                                "artemis configuration to do either of the settings
                                 Alert only,
                                 Alert and Block or
                                 Alert, Block and TCP-Reset."
        ::= { malwareGrp 6 }


-- Support for malwareUDFDetectionMode is deprecated in sensors using new MIB.
malwareUDFDetectionMode    OBJECT-TYPE
                        SYNTAX          INTEGER {
                                alertOnly(1),
                                alertAndBlock(2),
				alertBlockAndTCP-Reset(3)
                        }
                        MAX-ACCESS      read-write
                        STATUS          current
                        DESCRIPTION
                                "user-defined configuration to do either of the settings
                                 Alert only,
                                 Alert and Block or
                                 Alert, Block and TCP-Reset."
        ::= { malwareGrp 7 }


gamEngSensorCfgGrp     OBJECT IDENTIFIER ::= { malwareGrp 8 }

gamEngSensorAutoUpdateConfig OBJECT-TYPE
	SYNTAX TruthValue
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	       "Enable / disable the Sensor auto update config.
                Default : True (Enable)"
	::= { gamEngSensorCfgGrp  1}

gamEngSensorAutoUpdateInterval OBJECT-TYPE
	SYNTAX INTEGER (90..1440)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	       "Sets the Sensor auto update Interval in minutes.
                Default : 90"
	::= { gamEngSensorCfgGrp  2}

gamEngVer  OBJECT-TYPE 
        SYNTAX  DisplayString (SIZE(1..63))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "Provides the current gam engine version available on sensor."
        ::= { gamEngSensorCfgGrp  3}

gamDatVer  OBJECT-TYPE 
        SYNTAX  DisplayString (SIZE(1..63))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "Provides the current gam dat version available on sensor."
        ::= { gamEngSensorCfgGrp  4}

avEngVer  OBJECT-TYPE 
        SYNTAX  DisplayString (SIZE(1..63))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "Provides the current AV engine version available on sensor."
        ::= { gamEngSensorCfgGrp  5 }

avDatVer  OBJECT-TYPE 
        SYNTAX  DisplayString (SIZE(1..63))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "Provides the current AV dat version available on sensor."
        ::= { gamEngSensorCfgGrp  6}

gamEngUpdatedTime  OBJECT-TYPE 
        SYNTAX  Unsigned32
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "Provides the time in UTC format when sensor had updated GAM engine successfully."
        ::= { gamEngSensorCfgGrp  7}

gamManualFullUpdateFileUploadStatus OBJECT-TYPE
        SYNTAX INTEGER {
               readyForGAMUpdate (1),
               gAMUpdateTransferInProgress (2),
               gAMUpdateTransferError (3),
               gAMUpdateQueued (4),
               applyingGAMUpdate (5),
               gAMUpdateCompleted (6),
               gAMUpdateError (7)
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               "Provides the current file upload status."
        ::= { gamEngSensorCfgGrp  8}

--This group contains MIB objects related to Miscellaneous Configuration Group
miscCfgGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 33 }

jumboframeParsingConfig OBJECT-TYPE
                SYNTAX INTEGER {
                        enable (1),
                        disable (2)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Configuration option to enable/disable jumboframe parsing.
                         The new setting would be effective only after a sensor reboot.
                         Default: disable"
                ::= {miscCfgGrp 1 }

currentJumboframeParsingStatus OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The current running jumboframe parsing status."
                ::= {miscCfgGrp 2 }

appIdStatsConfigStatus  OBJECT-TYPE
	SYNTAX 	TruthValue
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"This object value if set to TRUE indicates that the appId stats collection is enabled for the sensor.
		Default: False"
	::= { miscCfgGrp 3 }

hitlessRebootStatus OBJECT-TYPE
                SYNTAX INTEGER {
                        available (1),
                        notavailable (2)
                }
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Status option to read whether hitless reboot is possible or not at this time."
                ::= {miscCfgGrp 4 }

existingGeoDBFilename OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE(0..256))
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "This specifies the name of geo database file present in sensor. NULL would be returned
                         when there is no geo DB file on the sensor."
                ::= {miscCfgGrp 5 }

nsmTrackUserLoggingStatus OBJECT-TYPE
                SYNTAX INTEGER {
                        enable (1),
                        disable (2)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Configuration option to enable/disable NSM audit logging.
                         Default: disable"
                ::= {miscCfgGrp 6 }

accelerateFTPInboundConfig OBJECT-TYPE
                SYNTAX TruthValue
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Configuration option to enable/disable accelerate ftp in inbound direction 
                         Default: false (2)"
                ::= {miscCfgGrp 7 }
                

accelerateFTPOutboundConfig OBJECT-TYPE
                SYNTAX TruthValue
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Configuration option to enable/disable accelerate ftp in outbound direction.
                         Default: false (2)"
                ::= {miscCfgGrp 8 }

parseTunnellingConfig OBJECT-TYPE
                 SYNTAX TruthValue
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                         "Configuration option to enable/disable parsing of tunnelled packet.
                          Default: false (2)"
                 ::= {miscCfgGrp 9 }

prev256ByteLoggingConfig OBJECT-TYPE
                 SYNTAX TruthValue
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                         "Configuration option to enable/disable prev 256 byte logging.
                          Default: false (2)"
                 ::= {miscCfgGrp 10 }

cliAuditLoggingConfig OBJECT-TYPE
                 SYNTAX TruthValue
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                         "Configuration option to enable/disable cli audit logging through SNMP.
                          Default: false (2)"
                 ::= {miscCfgGrp 11 }

snortRuleEngineConfig OBJECT-TYPE
                SYNTAX INTEGER {
                        traditional (1),
                        nextGeneration (2)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Configuration option to switch snort rule engine between traditional and next generation.
                         The new setting would be effective only after a sensor reboot.
                         Default: traditional"
                ::= {miscCfgGrp 12 }

currentSnortRuleEngineStatus OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The current running snort rule engine on sensor."
                ::= {miscCfgGrp 13 }

insightsTelemetryConfig OBJECT-TYPE
                SYNTAX  TruthValue
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Configuration option to enable/disable usage of configured telemetry data for Insights"
                ::= {miscCfgGrp 14}

--
-- This group contains MIB objects applicable to Layer2 forwarding.
--

layer2FwdGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 34 }

-- This group consists of scalars for configuring layer2 fwd feature.

layer2FwdCfgGrp OBJECT IDENTIFIER ::= { layer2FwdGrp 1 }


layer2FwdType   OBJECT-TYPE
                SYNTAX INTEGER {
                        tcp (1),
                        udp (2),
                        vlan(3),
                        all (4),
                        ip  (5)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        " Different modes for using layer2 forward feature."
                ::= { layer2FwdCfgGrp 1 }


layer2IntfPort OBJECT-TYPE
               SYNTAX     TrellixPortLinearIndex
               MAX-ACCESS read-write
               STATUS     current
               DESCRIPTION
                "The intf linear port index of the sensor for the mode chosen."
              ::= { layer2FwdCfgGrp 2 }


layer2FwdAction OBJECT-TYPE
                SYNTAX INTEGER {
                        enable (1),
                        disable (2),
                        clearAll(3)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        " Action to take for the specified port(s)."
                ::= { layer2FwdCfgGrp 3 }

layer2FwdBeginId OBJECT-TYPE
                 SYNTAX INTEGER
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                        " Start port id(range 1-65535) for the mode selected(tcp/udp/vlan)."
                ::= { layer2FwdCfgGrp 4 }


layer2FwdEndId   OBJECT-TYPE
                 SYNTAX INTEGER
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                        " End port id(range 1-65535) for the mode selected(tcp/udp/vlan)."
                ::= { layer2FwdCfgGrp 5 }

layer2FwdConfig OBJECT-TYPE
                SYNTAX  INTEGER (0..7)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        " Layer2 forward configuration to enable or disable this feature. Each bit represents the
                          layer2 forward type. From the LSB the 1st bit for TCP, 2nd bit for UDP, 3rd bit for VLAN.
                          Default will be 7, indicating this feature is enable"
                ::= { layer2FwdCfgGrp 6 }

--
-- This table has entries for layer2Fwd TCP Table.
--

layer2FwdTCPTable OBJECT-TYPE
                  SYNTAX SEQUENCE OF Layer2FwdTCPEntry
                  MAX-ACCESS  not-accessible
                  STATUS  current
                  DESCRIPTION
                    "Table containing TCP port ranges configured for L2 forwarding.(indexed via intf port number and entry number)."
                  ::= { layer2FwdGrp 2 }


layer2FwdTCPEntry   OBJECT-TYPE
                    SYNTAX Layer2FwdTCPEntry
                    MAX-ACCESS  not-accessible
                    STATUS  current
                    DESCRIPTION
                      "This MIB object contains all the attributes that are specific to the L2 fwd entry for TCP table. Indexed by intfPortLinearIndex and entry number."
                      INDEX { tcpIntfPortIndex,
                              tcpEntryIndex }
                ::= { layer2FwdTCPTable 1 }

Layer2FwdTCPEntry ::= SEQUENCE {
                tcpIntfPortIndex
                        TrellixPortLinearIndex,
                tcpEntryIndex
                        INTEGER,
                tcpPortRange
                        DisplayString
                }

tcpIntfPortIndex OBJECT-TYPE
              SYNTAX     TrellixPortLinearIndex
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                "The intfPort linear index"
              ::= { layer2FwdTCPEntry 1 }

tcpEntryIndex    OBJECT-TYPE
              SYNTAX     INTEGER
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                "The index"
              ::= { layer2FwdTCPEntry 2 }

tcpPortRange     OBJECT-TYPE
              SYNTAX          DisplayString(SIZE(0..20))
              MAX-ACCESS      read-only
              STATUS          current
              DESCRIPTION
                "range for which L2 forwarding feature is enabled. "
             ::= { layer2FwdTCPEntry 3 }



--
-- This table has entries for layer2Fwd UDP Table.
--

layer2FwdUDPTable OBJECT-TYPE
                  SYNTAX SEQUENCE OF Layer2FwdUDPEntry
                  MAX-ACCESS  not-accessible
                  STATUS  current
                  DESCRIPTION
                    "Table containing UDP port ranges configured for L2 forwarding.(indexed via intfPortIndex and entry number)."
                  ::= { layer2FwdGrp 3 }


layer2FwdUDPEntry   OBJECT-TYPE
                    SYNTAX Layer2FwdUDPEntry
                    MAX-ACCESS  not-accessible
                    STATUS  current
                    DESCRIPTION
                      "This MIB object contains all the attributes that are specific to the L2 fwd entry for UDP table. Indexed by intfPortLinearIndex and entry number."
                      INDEX { udpIntfPortIndex,
                              udpEntryIndex }
                ::= { layer2FwdUDPTable 1 }


Layer2FwdUDPEntry ::= SEQUENCE {
                udpIntfPortIndex
                        TrellixPortLinearIndex,
                udpEntryIndex
                        INTEGER,
                udpPortRange
                        DisplayString
                }
udpIntfPortIndex OBJECT-TYPE
              SYNTAX     TrellixPortLinearIndex
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                "The intfPort linear index"
              ::= { layer2FwdUDPEntry 1 }

udpEntryIndex    OBJECT-TYPE
              SYNTAX     INTEGER
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                "The index"
              ::= { layer2FwdUDPEntry 2 }

udpPortRange     OBJECT-TYPE
              SYNTAX          DisplayString(SIZE(0..20))
              MAX-ACCESS      read-only
              STATUS          current
              DESCRIPTION
                "range for which L2 forwarding feature is enabled. "
             ::= { layer2FwdUDPEntry 3 }


--
-- This table has entries for layer2Fwd VLAN Table.
--

layer2FwdVLANTable OBJECT-TYPE
        SYNTAX SEQUENCE OF Layer2FwdVLANEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                    "Table containing VLAN port ranges configured for L2 forwarding.(indexed via interface number and entry number)."
                  ::= { layer2FwdGrp 4 }


layer2FwdVLANEntry   OBJECT-TYPE
                    SYNTAX Layer2FwdVLANEntry
                    MAX-ACCESS  not-accessible
                    STATUS  current
                    DESCRIPTION
                      "This MIB object contains all the attributes that are specific to the
                       L2 fwd entry for VLAN table(indexed via intfPortLinearIndex and entry number)."
                INDEX { vlanIntfPortIndex,
                        vlanEntryIndex }
                ::= { layer2FwdVLANTable 1 }


Layer2FwdVLANEntry ::= SEQUENCE {
                vlanIntfPortIndex 
                        TrellixPortLinearIndex,
                vlanEntryIndex
                        INTEGER,
                vlanPortRange
                        DisplayString
                }

vlanIntfPortIndex OBJECT-TYPE
              SYNTAX     TrellixPortLinearIndex
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                "The intfPort linear index"
              ::= { layer2FwdVLANEntry 1 }

vlanEntryIndex    OBJECT-TYPE
              SYNTAX     INTEGER
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                "The entry index "
              ::= { layer2FwdVLANEntry 2 }

vlanPortRange OBJECT-TYPE
              SYNTAX          DisplayString(SIZE(0..20))
              MAX-ACCESS      read-only
              STATUS          current
              DESCRIPTION
                "range for which L2 forwarding feature is enabled. Maximum vlan range supported on each interface is 4k. "
             ::= { layer2FwdVLANEntry 3 }

layer2FwdIPTable OBJECT-TYPE
                  SYNTAX SEQUENCE OF Layer2FwdIPEntry
                  MAX-ACCESS not-accessible
                  STATUS current
                  DESCRIPTION
                    "Table containing IP protocol ranges configured for L2 forwarding.(indexed via intfPortIndex and entry number)."
                  ::= { layer2FwdGrp 5 }


layer2FwdIPEntry   OBJECT-TYPE
                    SYNTAX Layer2FwdIPEntry
                    MAX-ACCESS not-accessible
                    STATUS current
                    DESCRIPTION
                      "This MIB object contains all the attributes that are specific to the L2 fwd. entry for IP table. Indexed by intfPortLinearIndex and entry number."
                      INDEX { ipIntfPortIndex,
                              ipEntryIndex }
                ::= { layer2FwdIPTable 1 }


Layer2FwdIPEntry ::= SEQUENCE {
                ipIntfPortIndex
                        TrellixPortLinearIndex,
                ipEntryIndex
                        INTEGER,
                ipPortRange
                        DisplayString
                }
ipIntfPortIndex OBJECT-TYPE
              SYNTAX     TrellixPortLinearIndex
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                "The intfPort linear index"
              ::= { layer2FwdIPEntry 1 }

ipEntryIndex    OBJECT-TYPE
              SYNTAX     INTEGER
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                "The index"
              ::= { layer2FwdIPEntry 2 }

ipPortRange     OBJECT-TYPE
              SYNTAX          DisplayString(SIZE(0..20))
              MAX-ACCESS      read-only
              STATUS          current
              DESCRIPTION
                "range for which L2 forwarding feature is enabled. "
             ::= { layer2FwdIPEntry 3 }

--This group contains MIB objects related to ARP Configuration
arpCfgGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 103 }

arpSDEnable     OBJECT-TYPE
                SYNTAX INTEGER {
                        enable (1),
                        disable (2)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Option to enable/disable ARP Spoof Detection.
                         Default: enable"
                ::= {arpCfgGrp 1 }

--This group contains MIB objects related to ARP Configuration

--This group contains MIB objects related to Packet Capture Configuration

pktCapCfgGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 35 }

pktCapMode     OBJECT-TYPE
                SYNTAX INTEGER {
                        disable (1),
                        portModeEnable (2),
                        fileModeEnable (3)
                        
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Option to select packet capture Mode.
                         File mode is not supported in 6.x release.
                         Default: disable"
                ::= {pktCapCfgGrp 1 }

pktCapDuration   OBJECT-TYPE
                 SYNTAX  INTEGER (0..315360000)
                 MAX-ACCESS  read-write
                 STATUS  current
                 DESCRIPTION
                 "The duration for which capture will be enabled..
                 Units are in seconds. Default: 120 seconds
                 duration value 0 indicate indefinite capture till the capture 
                 is stopped.
                 Default: 120"
                  ::= { pktCapCfgGrp 2 }

pktCapPmSpanPortForCapture  OBJECT-TYPE
               SYNTAX     TrellixPortLinearIndex 
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Span linear port index for the capture: 
                ISM also needs to verify that port should be configured 
                as Span port.
                Applicable only for port mode capture. Zero indicates no port assigned.
		Default: 0"
                ::= { pktCapCfgGrp 3 }


pktCapFmLocation  OBJECT-TYPE
                 SYNTAX INTEGER {
                        manager  (1),
                        tftpServer (2),
			scpServer (3)
                 }
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                 "This will determine whether capture file is to be uploaded to manager, tftpServer or ScpServer.
                 Note :Applicable only for file mode capture
                 Default: manager"
                 ::= {pktCapCfgGrp 4 }

pktCapFmMaxSize  OBJECT-TYPE
                SYNTAX  INTEGER (1..100)
                MAX-ACCESS  read-write
                STATUS  current
                DESCRIPTION
                "The size of the maximum capture file. 
                 It will be configurable but to the maximum value
                 of sensor define limit.
                 Default: 100 MB for M8000, M6050, M4050, M3050
                           58 MB for N450, Wilson
			   40 MB for Eagle, Diablo
                 Note :Applicable only for file mode capture"
                 ::= { pktCapCfgGrp 5 }

pktCapFmFUServerAddress  OBJECT-TYPE
                 SYNTAX  OCTET STRING (SIZE(50))
                 MAX-ACCESS  read-write
                 STATUS  current
                 DESCRIPTION
                 "File Upload server IPv4 / IPv6 address.
                 Note :Applicable only for file mode capture"
                 ::= { pktCapCfgGrp 6 }


pktCapFmFUFileName     OBJECT-TYPE
                 SYNTAX  DisplayString (SIZE(0..128))
                 MAX-ACCESS  read-write
                 STATUS  current
                 DESCRIPTION
                 "This specifies the name of the file with the source path on the file upload server.
		  This is optional. If not set, the filename used will be of the format 
		  '%DEVICE_NAME%-PacketCapture-%TimeStamp%.
                  Note :Applicable only for file mode capture"
                 ::= { pktCapCfgGrp 7 }

pktCapFmFUSetting      OBJECT-TYPE
                 SYNTAX INTEGER {
                        manual    (1),
                        automatic (2)
                 }
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                 " This option will determine whether user needs to
                  initiate the file upload or it will be done automatically.
                  Default: automatic
                  Note :Applicable only for file mode capture"
                 ::= {pktCapCfgGrp 8 }

pktCapFilterFileName     OBJECT-TYPE
                SYNTAX   DisplayString (SIZE(0..255)) 
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Packet Capture Filter File Name send by NSM using secure TFTP channel"
               ::= {pktCapCfgGrp 9 }
               
               
pktCapFilterFileTimeStamp     OBJECT-TYPE
                SYNTAX   INTEGER (0..4294967295) 
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Packet Capture FilterFile creationTimeStamp"
               ::= {pktCapCfgGrp 10 }

pktCapFmSCPUserName     OBJECT-TYPE
                SYNTAX   DisplayString (SIZE(0..128)) 
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "SCP Server Username.
			 Note :Applicable only for file mode capture and upload method is SCP"
               ::= {pktCapCfgGrp 12 }

pktCapFmSCPPassword     OBJECT-TYPE
                SYNTAX   DisplayString (SIZE(0..128)) 
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "SCP Server Password.
			 Note :Applicable only for file mode capture and upload method is SCP"
               ::= {pktCapCfgGrp 13 }

                        
pktCapCommandGrp  OBJECT IDENTIFIER ::= { pktCapCfgGrp 11 }

pktCapCmd     OBJECT-TYPE
                SYNTAX INTEGER {
                        start (1),
                        stop (2),
                        delete-filter-file(3),
                        cancel(4),
                        delete-pcap-file(5)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Option to start/stop packet capture feature and also
                         to delete filter file.
                         Default:  stop"
               ::= {pktCapCommandGrp 1 }

pktCapStatus     OBJECT-TYPE
                SYNTAX INTEGER {
                        running (1),
                        not-running (2)
                      }
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Option to access packet capture Status.
                         Default:  idle"
               ::= {pktCapCommandGrp 2 }

packetCaptureFmFUControl    OBJECT-TYPE
                SYNTAX INTEGER {
                        start (1),
                        stop (2),
			upload-to-NSM (3)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Option to control manual upload of the file.
                         Note :Applicable only for file mode capture
                         Default:  stop"
               ::= {pktCapCommandGrp 3 }

packetCaptureFmFileStatus     OBJECT-TYPE
                SYNTAX INTEGER {
                        fileUploadInProgress (1),
                        fileExistNotUploaded (2),
                        fileNotExist (3),
			fileUploadFailed (4),
			fileUploadDone (5),
			fileUploadNotStarted (6)
                        }
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Packet Capture File status.
                        Note :Applicable only for file mode capture
			Default : fileUploadNotStarted"
                        ::= {pktCapCommandGrp 4 }

packetCaptureFmTest    OBJECT-TYPE
                SYNTAX INTEGER {
                        start (1),
                        stop (2)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Option to test packet capture file upload function.
                         Note :Applicable only for file mode capture
                         Default:  stop"
               ::= {pktCapCommandGrp 5 }

packetCaptureFmTestStatus     OBJECT-TYPE
                SYNTAX INTEGER {
                        success (1),
                        failure (2),
                        resultNotValid (3),
			fileUploadServerConnectFailure (4),
			fileUploadServerConnectTimeout (5),
			fileUploadServerAuthenticationFailure (6),
                        fileUploadInProgress (7)
                        }
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Packet Capture File upload test status.
                        Note :Applicable only for file mode capture
			Default : resultNotValid"
                        ::= {pktCapCommandGrp 6 }

dnsCfgGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 36 }

priDNSServerIp   OBJECT-TYPE
                        SYNTAX          IpAddress
                        MAX-ACCESS      read-write
                        STATUS          current
                        DESCRIPTION
                                "IP address of the primary DNS server."
        ::= { dnsCfgGrp 1 }

secDNSServerIp   OBJECT-TYPE
                        SYNTAX          IpAddress
                        MAX-ACCESS      read-write
                        STATUS          current
                        DESCRIPTION
                                "IP address of the secondary DNS server."
        ::= { dnsCfgGrp 2 }

priDNSServerIpV6 OBJECT-TYPE
                        SYNTAX          Ipv6Address
                        MAX-ACCESS      read-write
                        STATUS          current
                        DESCRIPTION
                                "IPV6 address of the primary DNS server."
        ::= { dnsCfgGrp 3 }

secDNSServerIpV6 OBJECT-TYPE
                        SYNTAX          Ipv6Address
                        MAX-ACCESS      read-write
                        STATUS          current
                        DESCRIPTION
                                "IPV6 address of the secondary DNS server."
        ::= { dnsCfgGrp 4 }

dnsSearchList OBJECT-TYPE
                        SYNTAX          OCTET STRING (SIZE(0..1024))
                        MAX-ACCESS      read-write
                        STATUS          current
                        DESCRIPTION
                                "This specifies the space separated list of search suffix for DNS lookup"
        ::= { dnsCfgGrp 5 }





--
-- This table has entries for layer7DCap Table.
--

layer7DCapConfigGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 37 }

layer7DCapPercentageOfFlows  OBJECT-TYPE
        SYNTAX  INTEGER (1..100)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies percentage of flows allocated for L7 Dcap when
                 layer7 DCap feature is enabled."
        ::= { layer7DCapConfigGrp 1 }

layer7DCapBuffSize  OBJECT-TYPE
        SYNTAX  INTEGER (128..1500)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the size of the buffer to be captured when L7 Dap feature is enabled .
.                Default: 1500"
        ::= { layer7DCapConfigGrp 2 }


layer7DCapMaxSupportedFlows  OBJECT-TYPE
        SYNTAX  INTEGER (1..4294967295)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object specifies maximum number of flows supported for L7 Dcap when L7 Dap feature is enabled ."
        ::= { layer7DCapConfigGrp 3 }


 interfacePhysicalPortGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 38 }

 intfPhysicalPortTable  OBJECT-TYPE
   SYNTAX SEQUENCE OF IntfPhysicalPortEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
       "Table containing entries for each interface physical port (indexed via intfPhysicalPortIndex)
       on each sensor card (indexed via appropriate slotIndex).

       This table contains Trellix specific configuration objects.
       Tables that contain MIB objects borrowed from MIB-II are in the
       TRELLIX-SENSOR-PERF-MIB."
   ::= { interfacePhysicalPortGrp 1 }

 intfPhysicalPortEntry  OBJECT-TYPE
   SYNTAX  IntfPhysicalPortEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
       "This MIB object contains all the columnar objects,
       that describe the contents of each interface physical port on each IntruShield sensor card.
       Indexed by slotIndex/intfPhysicalPortIndex"
   INDEX { slotIndex,
       intfPhysicalPortIndex }
   ::= { intfPhysicalPortTable 1 }

 IntfPhysicalPortEntry ::= SEQUENCE {
   intfPhysicalPortIfDescr
       DisplayString,
   intfPhysicalPortIfType
       TrellixIDSPortType,
   intfPhysicalPortIfAdminStatus
       INTEGER,
   intfPhysicalPortIfOperStatus
       INTEGER,
   intfPhysicalPortEnableFullDuplex
       TruthValue,
   intfPhysicalPortSpeed
       INTEGER,
   intfPhysicalPortSpeedConfig
       TrellixPortSpeed, -- was TrellixFEType, now deprecated
   intfPhysicalPortIsMcafeeConnector
         TruthValue,
     intfPhysicalPortAllowAnyConnector
         TruthValue,
     intfPhysicalPortCageType
         INTEGER,
     intfPhysicalPortGetMediaType
         INTEGER,
     intfPhysicalPortSetMediaType
         INTEGER,
   intfPhysicalPortMonPortIpAddress
       IpAddress,
   intfPhysicalPortMonPortNetMask
       IpAddress,
   intfPhysicalPortGatewayIpAddress
       IpAddress,
   intfPhysicalPortNbadConfigStatus
       TruthValue,
   intfPhysicalPortVlanId
       Integer32,
     intfPhysicalPortLBSerialNumber
         DisplayString,
     intfPhysicalPortLBPortNumber
         Integer32,
     intfPhysicalPortConnectorType
         INTEGER,
     intfPhysicalPortLinearIndex
         TrellixPortLinearIndex
 }
intfPhysicalPortIfDescr  OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..255))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "A textual string containing information about the interface.
        Returns the string that is printed on the box."
    ::= { intfPhysicalPortEntry 1 }

intfPhysicalPortIfType  OBJECT-TYPE
    SYNTAX  TrellixIDSPortType
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "The type of interface, distinguished according to the
        physical/link protocol(s) immediately 'below' the network
        layer in the protocol stack.

        For brevity, Trellix options are as specified by the TC,
        TrellixIDSPortType.

        However, the SNMP MIB-II - Interfaces MIB specifies many more
        valid options. See comments section for details.
        "
    ::= { intfPhysicalPortEntry 2 }

intfPhysicalPortIfAdminStatus  OBJECT-TYPE
    SYNTAX  INTEGER {
        up (1),
        down (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "The desired state of the interface.
        The testing(3) state indicates that no operational packets
        can be passed.

        Default: down"
    ::= { intfPhysicalPortEntry 3 }
intfPhysicalPortIfOperStatus  OBJECT-TYPE
    SYNTAX  INTEGER {
        up (1),
        down (2)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "The current operational state of the interface.
        The testing(3) state indicates that no operational packets
        can be passed.

        Default: down"
    ::= { intfPhysicalPortEntry 4 }

intfPhysicalPortEnableFullDuplex  OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "True: Sets interface port to work as a full-duplex one.
        Otherwise as half-duplex.

        Default: True"
    ::= { intfPhysicalPortEntry 5 }

intfPhysicalPortSpeed  OBJECT-TYPE
    SYNTAX  INTEGER {
        other (0),
        ten-Mbps (1),
        hundred-Mbps (2),
        one-Gbps(3), -- renamed from gig-Mbps
        ten-Gbps(4)  -- support in M-series only
    }

    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "Get current speed/negotiation on the interface."
    ::= { intfPhysicalPortEntry 6 }
intfPhysicalPortSpeedConfig  OBJECT-TYPE
    SYNTAX  TrellixPortSpeed -- was TrellixFEType, now deprecated
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "Set desired speed/negotiation on the interface.
                 Default values are as follows:
    I-Series -
        fixed-hundred-Mbps (infinity/hichborn/2x00(1a-3b)
        auto-gig-Mbps on 3000/4010/4000/2x00(4a,4b)
    M-Series -
        auto-ten-gig-Mbps on palomar/pyramid(1a-4b),auto-gig-Mbps(5a-8b)
        Default: see above"
    ::= { intfPhysicalPortEntry 7 }

-- intfPhysicalPortIsMcafeeConnector support in M-series sensor only
intfPhysicalPortIsMcafeeConnector  OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "True: connector is not inserted.
         True: connector is inserted in port and McAfee certified.
                 False: connector is inserted and not McAfee certified.  "
    ::= { intfPhysicalPortEntry 8 }

-- intfPhysicalPortAllowAnyConnector support in M-series sensor only
intfPhysicalPortAllowAnyConnector  OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "True: Permit usage of any connector for port.
                 False: Restrict usage to McAfee certified connector only.
        Default: False"
    ::= { intfPhysicalPortEntry 9 }
-- intfPhysicalPortCageType support in M-series sensor only
intfPhysicalPortCageType  OBJECT-TYPE
    SYNTAX  INTEGER {
        other (0),
        rJ-45 (1),
        rJ-11 (2),
        gBIC (3),
        sFP (4),
        xFP (5)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "Physical connector cage type on sensor chassis panel."
    ::= { intfPhysicalPortEntry 10 }

-- intfPhysicalPortGetMediaType support in M-series sensor only
intfPhysicalPortGetMediaType OBJECT-TYPE
    SYNTAX  INTEGER {
        none (0),
        optical (1),
        electrical (2)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "Gets the media of the connector present in the port cage. None (0) if cage is empty."
    ::= { intfPhysicalPortEntry 11 }

-- intfPhysicalPortSetMediaType support in M-series sensor only
intfPhysicalPortSetMediaType OBJECT-TYPE
    SYNTAX  INTEGER {
        optical(1),
        electrical (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "Sets the media of the connector the user desired for the port.
        Default: optical"
    ::= { intfPhysicalPortEntry 12 }
intfPhysicalPortMonPortIpAddress OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object is used to configure / retrieve the IPv4 address of the monitoring port.
         Default: 0.0.0.0"
    ::= { intfPhysicalPortEntry 13 }

intfPhysicalPortMonPortNetMask OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object is used to configure / retrieve netmask for the IPv4 address of the monitoring port.
         Default: 0.0.0.0"
    ::= { intfPhysicalPortEntry 14 }

intfPhysicalPortGatewayIpAddress OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object is used to configure / retrieve the IPv4 address of the gateway.
         Default: 0.0.0.0"
    ::= { intfPhysicalPortEntry 15 }

intfPhysicalPortNbadConfigStatus OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object value if set to TRUE indicates that flow record generation
         to be sent to the NBAD server, is enabled over this monitoring port.
        Default: False"
    ::= { intfPhysicalPortEntry 16 }
intfPhysicalPortVlanId  OBJECT-TYPE
    SYNTAX  Integer32 (0..2164326399)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This MIB object indicates the Vlan ID of the VLAN to which the monitoring
         port is connected."
    ::= { intfPhysicalPortEntry 17 }

intfPhysicalPortLBSerialNumber OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(1..80))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
             "This MIB object indicates the manufacturer provided serial number of
              the Load Balancer switch to which the sensor port is connected."
    ::= { intfPhysicalPortEntry 18 }


intfPhysicalPortLBPortNumber OBJECT-TYPE
    SYNTAX Integer32 (1..16)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
             "This MIB object returns the port number on the Load Balancer switch to
              which the sensor port is connected."
    ::= { intfPhysicalPortEntry 19 }

-- intfPhysicalPortConnectorType support in R-series sensor only
intfPhysicalPortConnectorType  OBJECT-TYPE
        SYNTAX  INTEGER {
                other (0),
                qSFP (1),
                sFP-plus (2),
                sFP-fiber (3),
                sFP-copper (4)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "Physical connector type plugged into the port cage."
        ::= { intfPhysicalPortEntry 20 }

intfPhysicalPortLinearIndex   OBJECT-TYPE
        SYNTAX  TrellixPortLinearIndex
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This MIB object indicates the Linear Index of the monitoring port. This index is
                generated by the sensor appliance using the pair of slot index and the port index values.
                The other MIB tables would directly use this linear index, whereever applicable."
        ::= { intfPhysicalPortEntry 21 }

--
-- This group has entries for GTI configuration.
--

gtiConfigGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 39 }

gtiProxyServerName  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(1..80))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The proxy server name is the domain name of the HTTP proxy
         server in front of the sensor. It looks like www.company.com.
         It can also be the IP address of the HTTP proxy server.
         0.0.0.0 is the default value"
	::= { gtiConfigGrp 1 }

gtiProxyPort  OBJECT-TYPE
	SYNTAX Integer32 (0..10000)
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"TCP Port on which the HTTP proxy server is listening. 
    0 is the default value"
	::= { gtiConfigGrp 2 }

gtiProxyUsername  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(0..80))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The username to be used to connect to the HTTP proxy server."
	::= { gtiConfigGrp 3 }

gtiProxyPassword  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(0..128))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"The password to be used to connect to the HTTP proxy server."
	::= { gtiConfigGrp 4 }

gtiConfigPrivateCloudGrp  OBJECT IDENTIFIER ::= { gtiConfigGrp 5 }

gtiPrivateCloudServerIPAddressType OBJECT-TYPE
        SYNTAX  INTEGER {
                ip-v4 (4),
                ip-v6 (6)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Identifies the type of GTI Private Cloud Server IP Address. If set to ip-v4, then the
                gtiPrivateCloudServerIPv4Address object would be set else if this object is set to ip-v6, then
                the gtiPrivateCloudServerIPv6Address object would be set. "
        ::= { gtiConfigPrivateCloudGrp 1 }

gtiPrivateCloudServerIPv4Address  OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IPv4 address of the GTI Private Cloud server.
                 The gtiPrivateCloudServerIPv6Address would be zero if the current object is initialized."
        ::= { gtiConfigPrivateCloudGrp 2 }

gtiPrivateCloudServerIPv6Address  OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IPv6 address of the GTI Private Cloud server.
                 The gtiPrivateCloudServerIPv4Address would be zero if the current object is initialized."
        ::= { gtiConfigPrivateCloudGrp 3 }

gtiPrivateCloudServerConnectionConfig OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2),
		reconnect (3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to enable or disable or reconnect the Connection with
                 the GTI Private Cloud Server.
                 Default: 2, disable"
        ::= { gtiConfigPrivateCloudGrp 4 }

gtiPrivateCloudServerDeleteCertificate  OBJECT-TYPE
        SYNTAX  INTEGER {
                delete (1),
                dont-delete (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to delete the GTI Private Cloud Server Certificate at the sensor.
              For deleting this certificate, the gtiPrivateCloudServerConnectionConfig should be
              disabled.  DEFAULT: 2, dont-delete"
        ::= { gtiConfigPrivateCloudGrp 5 }

gtiPrivateCloudServerCertificateStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                present (1),
                not-Present (2)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object is used to indicate the GTI Private Cloud server
                 certificate status at the sensor"
        ::= { gtiConfigPrivateCloudGrp 6 }

gtiPrivateCloudChannelStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                gtiPrivateCloud-TrustedSource-Channel-Down (0),
                gtiPrivateCloud-TrustedSource-Channel-InProgress (1),
                gtiPrivateCloud-TrustedSource-Channel-Established (2),
                gtiPrivateCloud-TrustedSource-Channel-Status-Unknown (3),
                gtiPrivateCloud-TrustedSource-Channel-Down-Error-In-Cert-ret(4),
                gtiPrivateCloud-Network-Issue (5)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object is used to indicate the gtiPrivateCloud channel status at
                 the sensor"
        ::= { gtiConfigPrivateCloudGrp 7 }

gtiUnifiedConfigGrp OBJECT IDENTIFIER ::= { gtiConfigGrp 6 }

gtiFileRESTGTIType OBJECT-TYPE
        SYNTAX  INTEGER {
                private-gti-server (1),
                public-gti-server (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to send type of GTI server to use for file reputation feature.
              DEFAULT: 2, public-gti-server"
        ::= { gtiUnifiedConfigGrp 1 }

gtiFileRESTPublicGTIFQDN OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(1..80))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to send Name Server or FQDN of File Rep GTI server.
              Default value is NULL"
        ::= { gtiUnifiedConfigGrp 2 }

gtiFileRESTUsername OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(1..80))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to send username for configured GTI server.
              It should be sent in both cases, public server and private server.
              Default value is NULL"
        ::= { gtiUnifiedConfigGrp 3 }

gtiFileRESTPassword OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(1..80))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to send password for configured GTI server.
              It should be sent in both cases, public server and private server.
              Default value is NULL"
        ::= { gtiUnifiedConfigGrp 4 }

gtiFileRESTConnectionConfig OBJECT-TYPE
        SYNTAX  INTEGER {
                connect-private-gti-server (1),
                connect-public-gti-server (2),
                reconnect-private-gti-server (3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to send action to take with the recieved config.
              Value 1 will be sent when config is changed to private GTI server first time.
              Value 2 will be sent when config is changed to public GTI server.
              Value 3 will be sent when private GTI server config is changed, given that
              private GTI server is enabled already. Default value: 2"
        ::= { gtiUnifiedConfigGrp 5 }

gtiFileRESTPvtGTIIPType OBJECT-TYPE
        SYNTAX  INTEGER {
                fqdn (1),
                ipv4 (4),
                ipv6 (6)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to send address type of configured GTI server.
              Default value: 4, IPv4"
        ::= { gtiUnifiedConfigGrp 6 }

gtiFileRESTPvtGTIIPv4Address OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IPv4 address of the GTI File-Rep REST Cloud server.
                 The gtiFileRESTPvtGTIIPV6Address would be zero if the current object is initialized.
                 Default Value: NULL"
        ::= { gtiUnifiedConfigGrp 7 }

gtiFileRESTPvtGTIIPV6Address OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IPv6 address of the GTI File-Rep REST Cloud server.
                 The gtiFileRESTPvtGTIIPv4Address would be zero if the current object is initialized.
                 Default Value: NULL"
        ::= { gtiUnifiedConfigGrp 8 }

 ntpConfigGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 40 }
 ntpConfigTable  OBJECT-TYPE
   SYNTAX SEQUENCE OF NtpConfigEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
       "Table containing entries for each NTP(Network Time Protocol) server that is specified (indexed via ntpServerIndex).
	A maximum of two entries will be supported. Valid ntpServerIndex values are 1 and 2."
   ::= { ntpConfigGrp 1 }

 ntpConfigEntry  OBJECT-TYPE
   SYNTAX  NtpConfigEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
       "Each entry comprises the ntp client side configuration for each of the ntp servers specified."
   INDEX { ntpServerIndex }
   ::= { ntpConfigTable 1 }

 NtpConfigEntry ::= SEQUENCE {
   ntpConfigServerIPv4
       IpAddress,
   ntpConfigServerIPv6
       Ipv6Address,
   ntpConfigPollInterval
       INTEGER,
   ntpConfigAuthenticationEnable
       TruthValue,
   ntpConfigKeyId
       Integer32,
   ntpConfigKeyType
       INTEGER,
   ntpConfigKeyValue
        OCTET STRING
 }
ntpConfigServerIPv4 OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object is used to specify the IPv4 address of the remote NTP server.
         Default: 0.0.0.0"
    ::= { ntpConfigEntry 1 }

ntpConfigServerIPv6  OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to specify the IPv6 address of the remote NTP server."
        ::= { ntpConfigEntry 2 }

ntpConfigPollInterval  OBJECT-TYPE
    SYNTAX  INTEGER (3..17)       
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object specifies the minimum poll interval. 
	 The value which is received represents the exponent of 2. If the received value is
	 x then NTPD daemon process will calculate the min poll as 2^x seconds.  
         Default: 6"

    ::= { ntpConfigEntry 3 }

ntpConfigAuthenticationEnable  OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object specifies if ntp server authentication is enabled or not for the specified
         ntp server.
	 False : Authentication Disable
	 True  : Authentication Enable
         Default: False"

    ::= { ntpConfigEntry 4 }

ntpConfigKeyId OBJECT-TYPE
    SYNTAX Integer32 (1..65534)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This MIB object specifies the key id for the corresponding association between an 
	 ntp server and ntp client. This object is used only if ntp server authentication is enabled. 
	 Default: 1"
    ::= { ntpConfigEntry 5 }

ntpConfigKeyType OBJECT-TYPE
    SYNTAX  INTEGER {
        md5 (1),
        sha (2),
	    sha1 (3),
		not-supported (4)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object specifies the key type for the corresponding key id. This object is used 
         only if ntp server authentication is enabled.	
         Default: MD5(1)"
    ::= { ntpConfigEntry 6 }

ntpConfigKeyValue  OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..128))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "This object specifies the symmetric key value for the corresponding key id. This object
	 is used only if ntp server authentication is enabled."
    ::= { ntpConfigEntry 7 }

ntpConfigFileCreate  OBJECT-TYPE
        SYNTAX  INTEGER {
                stop-ntpd (0),
                start-ntpd (1)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to (create ntp.conf file and start)/(stop) ntpd process.
		 Default: stop-ntpd (0)"
        ::= { ntpConfigGrp 2 }

-- This group conatins all MIB objects that specify the configuration of 
-- the IntruShield pluggable modules.
--
-- The object pluggableModuleTable within this group suggests that the MIB is 
-- designed to support pluggable modules that can contain more than one interface 
-- port.
--
-- Support for pluggableModuleGrp is deprecated in V-series sensors(VmIPS).
pluggableModuleGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 41 }

pluggableModuleTable  OBJECT-TYPE
  SYNTAX SEQUENCE OF PluggableModuleEntry
  MAX-ACCESS  not-accessible
  STATUS  current
  DESCRIPTION
    "Table containing entries for each pluggable Module (indexed via slotIndex)."
    ::= { pluggableModuleGrp 1 }

pluggableModuleEntry  OBJECT-TYPE
  SYNTAX  PluggableModuleEntry
  MAX-ACCESS  not-accessible
  STATUS  current
  DESCRIPTION
    "This MIB object contains all the columnar objects,
     that describe the contents of each pluggable module on each IntruShield sensor
     card. Indexed by slotIndex"
     INDEX { slotIndex }
     ::= { pluggableModuleTable 1 }

PluggableModuleEntry ::= SEQUENCE {
  moduleSerialNumber
   DisplayString,
  moduleSysType
   TrellixPluggableModuleType,
  modulePresent
   TruthValue,
  moduleNumPorts
   INTEGER,
  moduleRebootRequired
	 TruthValue
}

moduleSerialNumber  OBJECT-TYPE
  SYNTAX  DisplayString (SIZE(0..255))
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
		"This object describes the Manufacturer-provided serial number 
		 of the pluggable module."
  ::= { pluggableModuleEntry 1 }

moduleSysType  OBJECT-TYPE
  SYNTAX  TrellixPluggableModuleType
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
    "This object describes the type of the module plugged in."
  ::= { pluggableModuleEntry 2 }

modulePresent  OBJECT-TYPE
  SYNTAX  TruthValue
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
    "True: Indicates the module is present.
     Otherwise not present.
     Default: False"
  ::= { pluggableModuleEntry 3}

moduleNumPorts  OBJECT-TYPE
  SYNTAX  INTEGER (0..12)
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
    "This MIB object returns the number of ports in this module."
  ::= { pluggableModuleEntry 4 }

moduleRebootRequired  OBJECT-TYPE
	SYNTAX 	TruthValue
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
    "This MIB object returns whether a reboot is needed to apply the module.
		Default: False"
  ::= { pluggableModuleEntry 5 }


--
-- insightixNetworkGrp
--

insightixNetworkGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 42 }

insightixCfgGrp  OBJECT IDENTIFIER ::= { insightixNetworkGrp 1 }

ldapServerIPAddressType OBJECT-TYPE
        SYNTAX  INTEGER {
                ip-v4 (4),
                ip-v6 (6)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "Identifies the type of  Insightix LDAP server IPAddress. If set to ip-v4, then the
                ldapServerIpv4Address object would be set else if this object is set to ip-v6, then
                the ldapServerIpv6Address object would be set. "
        ::= { insightixCfgGrp 1 }

ldapServerIPv4Address  OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The IPv4 address of the Insightix LDAP server"
        ::= { insightixCfgGrp 2 }

ldapServerIPv6Address  OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "IPv6 Address of the Insightix LDAP server."
        ::= { insightixCfgGrp 3 }

ldapServerPort OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
                "The ldap server listener port on the insightix server. If SSL is enabled, the standard portnum is 636,
                else if ssl is disabled, the standard portnum is 389.
                 Default: 636"
        ::= { insightixCfgGrp 4 }

ldapServerSSLConfig OBJECT-TYPE
        SYNTAX  INTEGER {
		enable (1),
		disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Specifies if SSL is enabled for insightix ldap server. 
                Default: 1, enable"
        ::= { insightixCfgGrp 5 }

ldapServerBaseDN  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(3..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Base Distinguished Name to be used for retrieving device profile information from the Insightix ldap server.
		Default : dc=insightix"
	::= { insightixCfgGrp 6 }

ldapServerUserName  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(3..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"UserName to be used for authenticating to the Insightix ldap server."
	::= { insightixCfgGrp 7 }

ldapServerPassword  OBJECT-TYPE
	SYNTAX DisplayString (SIZE(3..255))	
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
		"Password to be used for authenticating to the Insightix ldap server."
	::= { insightixCfgGrp 8 }

ldapServerConfigAction  OBJECT-TYPE
	SYNTAX 	INTEGER {
		enable(1),
		disable(2)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"This object describes about the sensor's possible configuration actions with the insightix ldap server.
		Default: 2, disable"
	::= { insightixCfgGrp 9 }

ldapServerConfigStatus  OBJECT-TYPE
	SYNTAX 	INTEGER {
		disConnected (1),
                inProgress (2),
                connected (3),
		sslError(4),
		baseDNError(5),
		credError(6),
		ldapServerError(7),
		ldapServerTimeoutError(8),
		ldapServerConnectionError(9)
	}
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
		"This describes the sensor's possible insightix ldap server configuration states.
		 Default : deinstalled (4)"
	::= { insightixCfgGrp 10 }

--------------------------------------------------

--
-- ntbaChannelCfgGrp 
--

ntbaChannelCfgGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 43 }

ntbaServerIPAddressType OBJECT-TYPE
	SYNTAX 	INTEGER {
		ip-v4 (4),
		ip-v6 (6)
	}
	MAX-ACCESS  read-write 
	STATUS	current
	DESCRIPTION 
                "This object is used to configure the IP address type of the
                 mgmt port at the NTBA end"
	::= { ntbaChannelCfgGrp 1 }

ntbaServerIPv4Address  OBJECT-TYPE
	SYNTAX IpAddress	
	MAX-ACCESS  read-write 
	STATUS	current
	DESCRIPTION 
		"This object is used to configure the IPv4 address of the NTBA server.
                 The ntbaServerIPv6Address would be zero if the current object is initialized"
	::= { ntbaChannelCfgGrp 2 }

ntbaServerIPv6Address  OBJECT-TYPE
	SYNTAX 	Ipv6Address
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
                "This object is used to configure the IPv6 address of the NTBA server.
                 The ntbaServerIPv4Address would be zero if the current object is initialized"
	::= { ntbaChannelCfgGrp 3 }

ntbaServerPort OBJECT-TYPE
	SYNTAX INTEGER (1..65535)	
	MAX-ACCESS read-write 
	STATUS	current
	DESCRIPTION 
		"This object is used to configure the NTBA Server Listening TCP port
                 Default: 8505" 
	::= { ntbaChannelCfgGrp 4 }

ntbaServerConnectionConfig OBJECT-TYPE
        SYNTAX  INTEGER {
		enable (1),
		disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to enable or disable the TCP Connection with
                 the NTBA server 
                Default: 2, disable"
        ::= { ntbaChannelCfgGrp 5 }

ntbaServerDeleteCertificate  OBJECT-TYPE
        SYNTAX  INTEGER {
                    delete (1),
                    dont-delete (2)
        }
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION 
             "This object is used to delete the ntba Server Certificate at the sensor.
              For deleting this certificate, the ntbaServerConnectionConfig should be
              disabled.  DEFAULT: 2, dont-delete"
	::= { ntbaChannelCfgGrp 6 }

ntbaServerCertificateStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                     present (1),
                     not-present (2)
        }
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION 
		"This object is used to indicate the NTBA server certificate status at
                 the sensor"
	::= { ntbaChannelCfgGrp 7 }

ntbaShdKeySHAValue  OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE(128))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object contains the SHA1 hashed value of sensor name and sensormodel from NSM"
        ::= { ntbaChannelCfgGrp 8 }

ntbaChannelStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                     ntba-Channel-Down (0),
                     ntba-Channel-InProgress (1),
                     ntba-Channel-Established (2),
                     ntba-Channel-Status-Unknown (3),
                     ntba-Cert-Mismatch (4),
                     ntba-Hash-Mismatch (5),
                     ntba-Network-Issue (6)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object is used to indicate the NTBA SSL channel status at
                 the sensor"
        ::= { ntbaChannelCfgGrp 9 }

--------------------------------------------------

--
-- validEdgeChannelCfgGrp
--

validEdgeChannelCfgGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 44 }

validEdgeServerIPAddressType OBJECT-TYPE
        SYNTAX  INTEGER {
                ip-v4 (4),
                ip-v6 (6)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IP address type of the
                 mgmt port at the validEdge end"
        ::= { validEdgeChannelCfgGrp 1 }

validEdgeServerIPv4Address  OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IPv4 address of the validEdge server.
                 The validEdgeServerIPv6Address would be zero if the current object is initialized"
        ::= { validEdgeChannelCfgGrp 2 }

validEdgeServerIPv6Address  OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IPv6 address of the validEdge server.
                 The validEdgeServerIPv4Address would be zero if the current object is initialized"
        ::= { validEdgeChannelCfgGrp 3 }

validEdgeServerPort OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the validEdge Server Listening TCP port
                 Default: 8505"
        ::= { validEdgeChannelCfgGrp 4 }

validEdgeServerConnectionConfig OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to enable or disable the TCP Connection with
                 the validEdge server
                Default: 2, disable"
        ::= { validEdgeChannelCfgGrp 5 }

validEdgeServerDeleteCertificate  OBJECT-TYPE
        SYNTAX  INTEGER {
                    delete (1),
                    dont-delete (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to delete the validEdge Server Certificate at the sensor.
              For deleting this certificate, the validEdgeServerConnectionConfig should be
              disabled.  DEFAULT: 2, dont-delete"
        ::= { validEdgeChannelCfgGrp 6 }

validEdgeServerCertificateStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                     present (1),
                     not-present (2)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object is used to indicate the validEdge server certificate status at
                 the sensor"
        ::= { validEdgeChannelCfgGrp 7 }

validEdgeShdKeySHAValue  OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE(128))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object contains the SHA1 hashed value of sensor name and sensormodel from NSM"
        ::= { validEdgeChannelCfgGrp 8 }

validEdgeChannelStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                     validEdge-Channel-Down (0),
                     validEdge-Channel-InProgress (1),
                     validEdge-Channel-Established (2),
                     validEdge-Channel-Status-Unknown (3),
                     validEdge-Cert-Mismatch (4),
                     validEdge-Hash-Mismatch (5),
                     validEdge-Network-Issue (6),
                     validEdge-Channel-Down-Error-In-Cert-ret(7),
                     validEdge-Channel-Down-No-Config(8),
                     validEdge-Channel-Down-Wrong-Config(9),
                     validEdge-Channel-Down-Cert-Absent(10),
                     validEdge-Channel-SSL-HandShake-Fail(11),
                     validEdge-Channel-Down-Reason-Unknown(12),
                     validEdge-Channel-Down-Config-Disable(13),
                     validEdge-Channel-Down-Closed-By-NTBA(14),
                     validEdge-Channel-Down-Large-Pkt-From-NTBA(15),
                     validEdge-Channel-Down-Missed-KeepAlives(16),
                     validEdge-Channel-Up-No-Reason(17)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object is used to indicate the validEdge SSL channel status at
                 the sensor"
        ::= { validEdgeChannelCfgGrp 9 }

validEdgeChannelGlobalUserId  OBJECT-TYPE
        SYNTAX  INTEGER 
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure  global matd user id/profile id assigned to a sensor."
        ::= { validEdgeChannelCfgGrp 10 }


validEdgeChannelGlobalUserName OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE(32))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                " This object is used to configure global matd user name/profile name assigned to a sensor."
        ::= { validEdgeChannelCfgGrp 11 }


--------------------------------------------------

--
-- dxlCfgGrp
--

dxlCfgGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 45 }

dxlConfig  OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Option to enable(1) or dissable(2) the DXL on Sensor."
        ::= {dxlCfgGrp 1 }

epoCfgGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 46 }

epoIPAddressType OBJECT-TYPE
        SYNTAX  INTEGER {
                ip-v4 (4),
                ip-v6 (6)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "Identifies the type of EPO IPAddress. If set to ip-v4, then the epoIPAddress object
                 would be set else if this object is set to ip-v6, then the epoIPv6Address object
                 would be set."
        ::= { epoCfgGrp 1 }

epoIpAddress  OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The IPv4 Address of the EPO Server"
        ::= { epoCfgGrp 2 }

epoIPv6Address  OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "IPv6 Address of a EPO Server"
        ::= { epoCfgGrp 3 }
                                
epoPort OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
                "The EPO port through which MA connects to EPO Server Default: 8443"
        ::= { epoCfgGrp 4 }

epoCredUsername  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(3..100))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "EPO server :username"
        ::= { epoCfgGrp 5 }

epoCredPasswd  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(3..100))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "EPO server :Password"
        ::= { epoCfgGrp  6 }
                                
epoAction OBJECT-TYPE
        SYNTAX INTEGER {
                    connect (1),
                    disconnect (2),
                    reconnect (3)
        }
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
                "This config object indicates the epo action (1-Connect, 2-Disconnect, 3-Reconnect) to be taken 
                                                                by all the dependent modules in the sensor."
        ::= { epoCfgGrp 7 }

--User authentication using RADIUS

radiusAuthGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 47 }

radiusAuthConfig  OBJECT-TYPE
        SYNTAX INTEGER {
               enable (1),
               disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "This action object can be used to enable/re-init or disable user authentication using RADIUS.
         The value of 'True/Enable' would be interpreted as 're-init', when the configuration is already set to True/Enable.
        Default: False (2)"
        ::= { radiusAuthGrp 1}

radiusPrimaryServerIPAddrType OBJECT-TYPE
        SYNTAX  INTEGER {
                ip-v4 (4),
                ip-v6 (6)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Identifies the type of IPAddress of the Primary Radius Server. If set to ip-v4, then the radiusPrimaryServerIPAddr object
                 would be set else if this object is set to ip-v6, then the radiusPrimaryServerIPv6Addr object
                 would be set."
        ::= { radiusAuthGrp 2 }

radiusPrimaryServerIPAddr OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
        "This object specifies the IPv4 Address of the Primary RADIUS server"
        ::= { radiusAuthGrp 3 }

radiusPrimaryServerIPv6Addr OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the IPv6 Address of the Primary RADIUS Server"
        ::= { radiusAuthGrp 4 }


radiusPrimaryServerEncrSecret OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..64))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the secret to be used in generating the encrypted RADIUS traffic between the client and Primary Radius Server"
        ::= { radiusAuthGrp 5}

radiusPriServerAuthPort OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the port on which Primary RADIUS Server is listening for authentication requests.
                 Default: 1812"
        ::= { radiusAuthGrp 6}

radiusPriServerAccConfig OBJECT-TYPE
	SYNTAX TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "This object specifies whether accounting has to be enabled on the Primary Radius Server or not.
        Default: True (1)"
        ::= { radiusAuthGrp 7}

radiusPriServerAccPort OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the port on which Primary RADIUS Server is listening for accounting requests.
                 Default: 1813"
        ::= { radiusAuthGrp 8}

radiusPriServerConnTimeOut OBJECT-TYPE
        SYNTAX INTEGER (1..60)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
           "This object specifies the time in seconds the client  has to wait before it can contact the Backup RADIUS Server in case the Primary RADIUS Server fails.
            Default: 6"
        ::= { radiusAuthGrp 9}

radiusBackupServerIPAddrType OBJECT-TYPE
        SYNTAX  INTEGER {
                ip-v4 (4),
                ip-v6 (6)
        }
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
        "This object specifies the IP Address Type of the Backup RADIUS server"
        ::= { radiusAuthGrp 10 }


radiusBackupServerIPAddr OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
        "This object specifies the IPv4 Address of the Backup RADIUS server"
        ::= { radiusAuthGrp 11 }

radiusBackupServerIPv6Addr OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the IPv6 Address of the Backup RADIUS Server"
        ::= { radiusAuthGrp 12 }

radiusBackupServerEncrSecret OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..256))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the secret to be used in generating the encrypted RADIUS traffic between the client and Backup Radius Server"
        ::= { radiusAuthGrp 13 }

radiusBackupServerAuthPort OBJECT-TYPE
	SYNTAX INTEGER (1..65535)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the port on which Backup RADIUS Server is listening for authentication requests.
                 Default: 1812"
        ::= { radiusAuthGrp 14}

radiusBackupServerAccConfig OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "This object specifies whether accounting has to be enabled on the Backup Radius Server or not.
        Default: True (1)"
        ::= { radiusAuthGrp 15}

radiusBackupServerAccPort OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
                "This object specifies the port on which Backup RADIUS Server is listening for accounting requests.
                 Default: 1813"
        ::= { radiusAuthGrp 16}

radiusBackupServerConnTimeOut OBJECT-TYPE
        SYNTAX INTEGER (1..60)
        MAX-ACCESS read-write
        STATUS  current
        DESCRIPTION
           "This object specifies the time in seconds before which the the sensor decides that the Backup server is not responding.
            Default: 6"
        ::= { radiusAuthGrp 17}


sshAccessGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 48 }

sshAccessCfgGrp  OBJECT IDENTIFIER ::= { sshAccessGrp  1 }

sshAccessControlStatus OBJECT-TYPE
                 SYNTAX TruthValue
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                         "Configuration option to enable/disable ssh access control list for ipv4.
                          Default: false (2)"
                 ::= {sshAccessCfgGrp 1 }

sshAccessControlResetIpv4 OBJECT-TYPE
                 SYNTAX TruthValue
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                         "Configuration option to to delete/reset the ssh access ipv4 contol list.
                          Default: false (2)"
                 ::= {sshAccessCfgGrp 2 }

sshAccessLogSupport OBJECT-TYPE
                 SYNTAX TruthValue
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                         "Configuration option to enable/disable ssh access messages logging support.
                          Default: false (2)"
                 ::= {sshAccessCfgGrp 3 }

sshAccessControlResetIpv6 OBJECT-TYPE
                 SYNTAX TruthValue
                 MAX-ACCESS read-write
                 STATUS current
                 DESCRIPTION
                         "Configuration option to delete/reset ssh access control list for ipv6.
                          Default: false (2)"
                 ::= {sshAccessCfgGrp 4 }

sshAccessNumIpv4Entries  OBJECT-TYPE
        SYNTAX INTEGER (0..100)
        MAX-ACCESS read-only
        STATUS  current
        DESCRIPTION
            "This object ranges from 1 to 100, as only a maximum of 100 entries are supported."
        ::= { sshAccessGrp 2 }


sshAccessIpTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF SSHAccessIpEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
        "

        "
        ::= { sshAccessGrp 3 }

sshAccessIpEntry  OBJECT-TYPE
        SYNTAX  SSHAccessIpEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "Each entry specified is indexed by <sshIpv4Index>. "
        INDEX { sshIpv4Index }
        ::= { sshAccessIpTable 1 }

SSHAccessIpEntry ::= SEQUENCE {
        sshIpv4Index
            INTEGER,
        sshIpAddress
            IpAddress,
        sshMaskIpv4
            INTEGER,
        sshAccessIpConfig
            RowStatus
}

sshIpv4Index  OBJECT-TYPE
        SYNTAX INTEGER
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "This object sshIpv4Index ranges from 1 to 100, It support only 100 entries."
        ::= { sshAccessIpEntry 1 }

sshIpAddress  OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "IP Address of a SSH Access Control(ipv4)."
        ::= { sshAccessIpEntry 2 }

sshMaskIpv4  OBJECT-TYPE
        SYNTAX INTEGER (1..32)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Mask of a SSH Access Control(ipv4)."
        ::= { sshAccessIpEntry 3 }

sshAccessIpConfig  OBJECT-TYPE
    SYNTAX  RowStatus
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "This object used for user to add and delete rows in to the table."
    ::= { sshAccessIpEntry 4 }

sshAccessNumIpv6Entries  OBJECT-TYPE
        SYNTAX INTEGER (0..100)
        MAX-ACCESS read-only
        STATUS  current
        DESCRIPTION
            "This object ranges from 1 to 100, as only a maximum of 100 entries are supported."
        ::= { sshAccessGrp 4 }

sshAccessIpv6Table  OBJECT-TYPE
        SYNTAX SEQUENCE OF SSHAccessIpv6Entry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
        "

        "
        ::= { sshAccessGrp 5 }

sshAccessIpv6Entry  OBJECT-TYPE
        SYNTAX  SSHAccessIpv6Entry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
        "Each entry specified is indexed by <sshIpv6Index>.
        "
        INDEX { sshIpv6Index  }
        ::= { sshAccessIpv6Table  1}

SSHAccessIpv6Entry ::= SEQUENCE {
        sshIpv6Index
            INTEGER,
        sshAccessIpv6Address
            Ipv6Address,
        sshAccessIpv6Mask
            INTEGER,
        sshAccessIpv6Config
            RowStatus
}

sshIpv6Index  OBJECT-TYPE
        SYNTAX INTEGER
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
        "This object sshIpv6Index range from 1 to 100, It support max
100 entries"
        ::= { sshAccessIpv6Entry 1 }


sshAccessIpv6Address  OBJECT-TYPE
        SYNTAX Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "IPv6 address for the ssh access control list"
        ::= { sshAccessIpv6Entry 2 }

sshAccessIpv6Mask  OBJECT-TYPE
        SYNTAX INTEGER (1..128)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "IPv6 Mask for the ssh access control list"
        ::= { sshAccessIpv6Entry 3 }

sshAccessIpv6Config  OBJECT-TYPE
    SYNTAX  RowStatus
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "This object used for user to add and delete rows in to the table."
    ::= { sshAccessIpv6Entry 4 }

--------------------------------------------------
-- This group contains all MIB objects that specify the configuration of
-- pluggable modules for the VSS Switch Load Balancer to be used in conjunction with
-- existing MIB interfacePortGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 11 } which will be used as virtual interface port group of VSS switch.

virtualPluggableModuleGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 49 }

moduleOneNumPorts OBJECT-TYPE
  SYNTAX  INTEGER (0..16)
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
    "This MIB object returns the number of ports in the first module of VSS Box.
     To be used in conjunction with interfacePortGrp of { ivSensorConfigurationMIB 11 } to represent attributes of VSS switch virtual ports.
     Default: 0 (If the module is not inserted)"
  ::= { virtualPluggableModuleGrp 1 }

moduleTwoNumPorts OBJECT-TYPE
  SYNTAX  INTEGER (0..16)
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
    "This MIB object returns the number of ports in the first module of VSS Box.
     To be used in conjunction with interfacePortGrp of { ivSensorConfigurationMIB 11 } to represent attributes of VSS switch virtual ports.
     Default: 0 (If the module is not inserted)"
  ::= { virtualPluggableModuleGrp 2 }

--------------------------------------------------
--
-- sslProbeAccessGrp
--

sslProbeAccessGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 51 }

sslProbeAccessCfgGrp  OBJECT IDENTIFIER ::= { sslProbeAccessGrp  1 }

sslProbeAccessMaxAgentConn OBJECT-TYPE
		SYNTAX  INTEGER (1..1024)
		MAX-ACCESS  read-write
		STATUS  current
		DESCRIPTION
             "Configuration option to restrict the total number of  connections
			 that the sensor can handle from the SSL Probes.
                	Default: 1024"
		::= {sslProbeAccessCfgGrp 1 }

sslProbeAccessNumIpv4Entries  OBJECT-TYPE
        SYNTAX INTEGER (0..64)
        MAX-ACCESS read-only
        STATUS  current
        DESCRIPTION
            "This object ranges from 1 to 64, as only a maximum of 64 entries are supported."
        ::= { sslProbeAccessGrp 2 }


sslProbeAccessIpTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF SSLProbeAccessIpEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
        "

        "
        ::= { sslProbeAccessGrp 3 }

sslProbeAccessIpEntry  OBJECT-TYPE
        SYNTAX  SSLProbeAccessIpEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "Each entry specified is indexed by <sslProbeIpv4Index>. "
        INDEX { sslProbeIpv4Index }
        ::= { sslProbeAccessIpTable 1 }

SSLProbeAccessIpEntry ::= SEQUENCE {
        sslProbeIpAddress
            IpAddress,
        sslProbeMaskIpv4
            INTEGER,
        sslProbeAccessIpConfig
            RowStatus
}

sslProbeIpAddress  OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "IP Address of a SSL Probe Access Control(ipv4)."
        ::= { sslProbeAccessIpEntry 1 }

sslProbeMaskIpv4  OBJECT-TYPE
        SYNTAX INTEGER (1..32)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Mask of a SSL Probe Access Control(ipv4)."
        ::= { sslProbeAccessIpEntry 2 }

sslProbeAccessIpConfig  OBJECT-TYPE
    SYNTAX  RowStatus
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "This object used for user to add and delete rows in to the table."
    ::= { sslProbeAccessIpEntry 3 }

sslProbeAccessNumIpv6Entries  OBJECT-TYPE
        SYNTAX INTEGER (0..64)
        MAX-ACCESS read-only
        STATUS  current
        DESCRIPTION
            "This object ranges from 1 to 64, as only a maximum of 64 entries are supported."
        ::= { sslProbeAccessGrp 4 }

sslProbeAccessIpv6Table  OBJECT-TYPE
        SYNTAX SEQUENCE OF SSLProbeAccessIpv6Entry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
        "

        "
        ::= { sslProbeAccessGrp 5 }

sslProbeAccessIpv6Entry  OBJECT-TYPE
        SYNTAX  SSLProbeAccessIpv6Entry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
        "Each entry specified is indexed by <sslProbeIpv6Index>.
        "
        INDEX { sslProbeIpv6Index  }
        ::= { sslProbeAccessIpv6Table  1}

SSLProbeAccessIpv6Entry ::= SEQUENCE {
        sslProbeAccessIpv6Address
            Ipv6Address,
        sslProbeAccessIpv6Mask
            INTEGER,
        sslProbeAccessIpv6Config
            RowStatus
}

sslProbeAccessIpv6Address  OBJECT-TYPE
        SYNTAX Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "IPv6 address for the sslProbe access control list"
        ::= { sslProbeAccessIpv6Entry 1 }

sslProbeAccessIpv6Mask  OBJECT-TYPE
        SYNTAX INTEGER (1..128)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "IPv6 Mask for the sslProbe access control list"
        ::= { sslProbeAccessIpv6Entry 2 }

sslProbeAccessIpv6Config  OBJECT-TYPE
    SYNTAX  RowStatus
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "This object used for user to add and delete rows in to the table."
    ::= { sslProbeAccessIpv6Entry 3 }

--------------------------------------------------

--This group contains MIB objects related to Sensor Certificate Configuration

sensorCertificateGroup  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 52 }

sensorCertificateConfigGrp  OBJECT IDENTIFIER ::= { sensorCertificateGroup 1 }

sensorCertificateCSRConfigGrp OBJECT IDENTIFIER ::= { sensorCertificateConfigGrp 1 }

sensorCertificateCSRCountryName  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(1..255))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Country name for generating the CSR. Use the two-letter code
                without punctuation for country like US or CA."
        ::= { sensorCertificateCSRConfigGrp 1 }

sensorCertificateCSRStateProvince  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(1..255))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "State or Province name for generating the CSR. Spell out the
                state completely."
        ::= { sensorCertificateCSRConfigGrp 2 }

sensorCertificateCSRLocality  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(1..255))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "City or town name for generating the CSR."
        ::= { sensorCertificateCSRConfigGrp 3 }

sensorCertificateCSRCompany  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(1..255))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Company name for generating the CSR. If the company name has
                symbols, spell out the symbol or omit it to enroll."
        ::= { sensorCertificateCSRConfigGrp 4 }

sensorCertificateCSROrganizationalUnit  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(1..255))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The organizational unit is the name of the department or organization unit
                making the request. This is an optional field"
        ::= { sensorCertificateCSRConfigGrp 5 }

sensorCertificateCSRCommonName  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(1..255))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The common name is the host plus domain name. It looks like
                www.company.com or company.com."
        ::= { sensorCertificateCSRConfigGrp 6 }

sensorCertificateCSRGenerateAction  OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),
                generateCSR(1),
    generateSelfSigned(2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This action is used to generate the CSR/self signed certificate.
                 Default : other (0)"
        ::= { sensorCertificateCSRConfigGrp 7 }

sensorCertificateCSRGenerateStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                    other (0),
                generationInProgress (1),
                generationComplete (2),
                    generationFailed (3)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This object describes the possible CSR generation states.
                 Default : other (0)"
        ::= { sensorCertificateCSRConfigGrp 8 }

sensorCertSubAltName OBJECT-TYPE
        SYNTAX  INTEGER
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "To push sensorCert subject alternative name"
        ::= { sensorCertificateCSRConfigGrp 9 }

sensorCertificateStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                    other (0),
        certAbsent (1),
        defaultCert (2),
        selfsignedCert (3),
        casignedCert (4)
        }
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
    "This object indicates the cert status on the sensor.
    Default: 0"
  ::= { sensorCertificateConfigGrp 2 }

sensorCertMigrateAction OBJECT-TYPE
        SYNTAX  INTEGER
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
    "To push request for sensor cert migration"
  ::= { sensorCertificateConfigGrp 3 }

--------------------------------------------------

sensorStackGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 53 }

stackName  OBJECT-TYPE
        SYNTAX DisplayString (SIZE(1..80))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "Stack Name"
        ::= { sensorStackGrp 1 }

stackNodeId OBJECT-TYPE
        SYNTAX  INTEGER (1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "ID of stackNode."
        ::= { sensorStackGrp 2 }

stackNodeLeftNeighbour OBJECT-TYPE
        SYNTAX  INTEGER (1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "Node id of Left Neighbour, configured in stack"
        ::= { sensorStackGrp 3 }

stackNodeRightNeighbour OBJECT-TYPE
        SYNTAX  INTEGER (1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "Node id of Right Neighbour, configured in stack"
        ::= { sensorStackGrp 4 }


interfaceVirtualPortGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 54 }

intfVirtualPortTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF IntfVirtualPortEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "Table containing entries for each interface port (indexed via intfPortIndex)
                on each sensor card (indexed via appropriate slotIndex).

                This table contains Trellix specific configuration objects.
                Tables that contain MIB objects borrowed from MIB-II are in the
                TRELLIX-SENSOR-PERF-MIB."
        ::= { interfaceVirtualPortGrp 1 }

intfVirtualPortEntry  OBJECT-TYPE
        SYNTAX  IntfVirtualPortEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "This MIB object contains all the columnar objects,
                that describe the contents of each interface port on each IntruShield sensor card.
                Indexed by slotIndex/intfPortIndex"
        INDEX { intfVirtualSlotIndex,
                intfVirtualPortIndex }
        ::= { intfVirtualPortTable 1 }

IntfVirtualPortEntry ::= SEQUENCE {
        intfVirtualPortIfDescr
                DisplayString,
        intfVirtualPortIfType
                TrellixIDSPortType,
        intfVirtualPortIfAdminStatus
                INTEGER,
        intfVirtualPortOperatingMode
                TrellixIDSOperatingMode,
        intfVirtualPortEnableFullDuplex
                TruthValue,
        intfVirtualPortSpeedConfig
                TrellixPortSpeed,
        intfVirtualPortEnableInternalTap
                TruthValue,
        intfVirtualPortInOutType
                INTEGER,
        intfVirtualFailOpenSwitchStatus
                INTEGER,
        intfVirtualFailOpenPortStatus
                INTEGER,
        intfVirtualPortEnableAntiSpoofing
                INTEGER,
        intfVirtualPortAllowAnyConnector
                TruthValue,
        intfVirtualPortCageType
                INTEGER,
        intfVirtualPortSetMediaType
                INTEGER,
        intfVirtualPortMonPortIpAddress
                IpAddress,
        intfVirtualPortMonPortNetMask
                IpAddress,
        intfVirtualPortGatewayIpAddress
                IpAddress,
        intfVirtualPortNbadConfigStatus
                TruthValue,
        intfVirtualPortVlanId
                Integer32,
        intfVirtualPortAppIdStatsConfigStatus
                TruthValue,
        intfVirtualPortLinearIndex
                TrellixPortLinearIndex,
        intfVirtualPortFECConfig
                TruthValue
}

intfVirtualPortIfDescr  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "A textual string containing information about the interface.
                Returns the string that is printed on the box."
        ::= { intfVirtualPortEntry 1 }

intfVirtualPortIfType  OBJECT-TYPE
        SYNTAX  TrellixIDSPortType
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The type of interface, distinguished according to the
                physical/link protocol(s) immediately 'below' the network
                layer in the protocol stack.

                For brevity, Trellix options are as specified by the TC,
                TrellixIDSPortType.

                However, the SNMP MIB-II - Interfaces MIB specifies many more
                valid options. See comments section for details.
                "
        ::= { intfVirtualPortEntry 2 }

intfVirtualPortIfAdminStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                up (1),
                down (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The desired state of the interface.
                The testing(3) state indicates that no operational packets
                can be passed.

                Default: down"
        ::= { intfVirtualPortEntry 3 }

intfVirtualPortOperatingMode  OBJECT-TYPE
        SYNTAX  TrellixIDSOperatingMode
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "ReadWrite parameter specifies the operating mode for the
                Trellix IDS sensor to be used. Different modes supported are
                inline-fo-passive(1), non-inline or tap(2), span(3) and
                inlne-fc(4), inline-fo-active kit(5 - available on M-series only).

                Default: non-inline"
        ::= { intfVirtualPortEntry 4 }

intfVirtualPortEnableFullDuplex  OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "True: Sets interface port to work as a full-duplex one.
                Otherwise as half-duplex.

                Default: True"
        ::= { intfVirtualPortEntry 5 }

intfVirtualPortSpeedConfig  OBJECT-TYPE
        SYNTAX  TrellixPortSpeed -- was TrellixFEType, now deprecated
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Set desired speed/negotiation on the interface."
        ::= { intfVirtualPortEntry 6 }

intfVirtualPortEnableInternalTap  OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Set to TRUE to enable feature. Applies to Fast Ethernet (FE)
                ports only (see TrellixIDSPortType).
                For non FE ports, set to 'FALSE' .
                Setting this to 'TRUE' requires that
                <intfPortCurrentOperatingMode> is already set to
                'monitor-dual-intf'
                Default: True"

        ::= { intfVirtualPortEntry 7 }

intfVirtualPortInOutType  OBJECT-TYPE
        SYNTAX  INTEGER {
                inside (1),
                outside (2),
                not-specified (3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This MIB object reflects the Input or Output labeling
                of this interface port. Used only when operating mode
                is inline(1) or monitor-dual-intf(2).

                Default: not-specified(3)"
        ::= { intfVirtualPortEntry 8 }

intfVirtualFailOpenSwitchStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                not-applicable(1),
                present(2),
                not-present(3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Returns the status of the external optical bypass switch
                status. For FE ports, this object will return
                not-applicable(1). For GE ports, if external optical bypass
                switch is connected to sensor ports, this will return
                present(2). Otherwise, it will return not-present(3)."
        ::= { intfVirtualPortEntry 9 }

intfVirtualFailOpenPortStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                not-applicable(1),
                inline-fail-open(2),
                bypass(3),
                tap (4),
                absent (5),
                unknown (6),
                layer2-bypass (7)

        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Returns the packet forwarding status of the sensor ports connected to the optical bypass switch.
                If status is inline-fail-open(2), sensor is doing the
                forwarding. If status is bypass(3), the bypass switch is
                doing the forwarding and sensor will not process any
                traffic in this mode. Tap(4), absent(5) , unknown (6) and layer2-bypass(7)
                are available only in M-series for non RJ45(captive) ports
                when connected to active FO kit and sensor operating mode
                is inline-fail-open-active-kit.
                tap - operational status(up), kit(present), heart-beat(tap)
                absent - operational status(up), kit(absent), hear-beat(none)
                unknown - operational status(down), kit(absent), heart-beat(not available)."
        ::= { intfVirtualPortEntry 10 }

intfVirtualPortEnableAntiSpoofing  OBJECT-TYPE
        SYNTAX  INTEGER {
                disable-bothsides-spoof-detect (1),
                enable-inside-spoof-detect (2),
                enable-outside-spoof-detect (3),
                enable-bothsides-spoof-detect (4)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "spoofed packet detect rcvd on the both sides .

                Default: 'disable-bothsides-spoof-detect' (0) "
        ::= { intfVirtualPortEntry 11 }

intfVirtualPortAllowAnyConnector  OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "True: Permit usage of any connector for port.
                 False: Restrict usage to McAfee certified connector only.
                Default: False"
        ::= { intfVirtualPortEntry 12 }

intfVirtualPortCageType  OBJECT-TYPE
        SYNTAX  INTEGER {
                other (0),
                rJ-45 (1),
                rJ-11 (2),
                gBIC (3),
                sFP (4),
                xFP (5),
                sFP-plus (6), -- support in R-series only
                qSFP (7), -- support in R-series only
                rJ-45-plus (8), --  support in R-series only
                sFP-plus-BPFO (9) --  support in R-series only
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Physical connector cage type on sensor chassis panel."
        ::= { intfVirtualPortEntry 13 }

intfVirtualPortSetMediaType OBJECT-TYPE
        SYNTAX  INTEGER {
                optical(1),
                electrical (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Sets the media of the connector the user desired for the port.
                Default: optical"
        ::= { intfVirtualPortEntry 14 }

intfVirtualPortMonPortIpAddress OBJECT-TYPE
        SYNTAX  IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure / retrieve the IPv4 address of the monitoring port.
                 Default: 0.0.0.0"
        ::= { intfVirtualPortEntry 15 }

intfVirtualPortMonPortNetMask OBJECT-TYPE
        SYNTAX  IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure / retrieve netmask for the IPv4 address of the monitoring port.
                 Default: 0.0.0.0"
        ::= { intfVirtualPortEntry 16 }

intfVirtualPortGatewayIpAddress OBJECT-TYPE
        SYNTAX  IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure / retrieve the IPv4 address of the gateway.
                 Default: 0.0.0.0"
        ::= { intfVirtualPortEntry 17 }

intfVirtualPortNbadConfigStatus OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object value if set to TRUE indicates that flow record generation
                 to be sent to the NBAD server, is enabled over this monitoring port.
                Default: False"
        ::= { intfVirtualPortEntry 18 }

intfVirtualPortVlanId  OBJECT-TYPE
        SYNTAX  Integer32 (0..2164326399)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This MIB object indicates the Vlan ID of the VLAN to which the monitoring
                 port is connected."
        ::= { intfVirtualPortEntry 19 }

intfVirtualPortAppIdStatsConfigStatus  OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object value if set to TRUE indicates that the appId stats collection is enabled
         over this monitoring port.
                Default: True"
        ::= { intfVirtualPortEntry 20 }


intfVirtualPortLinearIndex   OBJECT-TYPE
        SYNTAX  TrellixPortLinearIndex
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This MIB object indicates the Linear Index of the monitoring port. This index is
                generated by the sensor appliance using the pair of slot index and the port index values.
                The other MIB tables would directly use this linear index, whereever applicable."
        ::= { intfVirtualPortEntry 21 }

intfVirtualPortFECConfig OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object value if set to TRUE indicates that FEC is enabled, FALSE for FEC disbaled
                Default: False"
        ::= { intfVirtualPortEntry 22 }

-- responseVirtualPortGrp 'ivSensorConfigurationMIB 55' is not supported currently, reserved for future use
responseVirtualPortGrp  OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 55 }

respVirtualPortTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF RespVirtualPortEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "Table containing entries for each response port (indexed via respPortIndex)
                on each sensor card (indexed via valid slotIndex).

                This table contains Trellix specific MIB objects.
                "
        ::= { responseVirtualPortGrp 1 }

respVirtualPortEntry  OBJECT-TYPE
        SYNTAX  RespVirtualPortEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "This MIB object contains all the columnar objects,
                that describe the contents of each response port within the Trellix IDS sensor card.
                Indexed by slotIndex/respPortIndex"
        INDEX { slotIndex,
                respPortIndex }
        ::= { respVirtualPortTable 1 }

RespVirtualPortEntry ::= SEQUENCE {
        respVirtualPortDescr
                DisplayString,
        respVirtualPortType
                TrellixIDSPortType,
        respVirtualPortAdminStatus
                INTEGER,
        respVirtualPortOperStatus
                INTEGER,
        respVirtualPortEnableFullDuplex
                TruthValue,
        respVirtualPortSpeed
                TrellixPortSpeed, -- was TrellixFEType,
        respVirtualPortPktDestination
                INTEGER,
        respVirtualPortMacAddress
                MacAddress,
        respVirtualCUGEPortSpeed
                TrellixCUGEType,
        respVirtualAdditionalInfo
                DisplayString

}

respVirtualPortDescr  OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "A textual string containing information about the interface.
                Returns the string that is printed on the box."
        ::= { respVirtualPortEntry 1 }

respVirtualPortType  OBJECT-TYPE
        SYNTAX  TrellixIDSPortType
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The type of interface, distinguished according to the
                physical/link protocol(s) immediately 'below' the network
                layer in the protocol stack.
                See  TrellixIDSPortType.
                "
        ::= { respVirtualPortEntry 2 }

respVirtualPortAdminStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                up (1),
                down (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "The desired state of the interface.
                Default: Up"
        ::= { respVirtualPortEntry 3 }

respVirtualPortOperStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                up (1),
                down (2)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "The current operational state of the interface.
                The testing(3) state indicates that no operational packets
                can be passed."
        ::= { respVirtualPortEntry 4 }

respVirtualPortEnableFullDuplex  OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "True: Sets response port to work as a full-duplex one.
                otherwise as half-duplex.
                If True, respPortFullDuplexPeer must be specified.

                Default: False
                "
        ::= { respVirtualPortEntry 5 }

-- Support for respPortSpeed is deprecated in V-series sensors(VmIPS).
respVirtualPortSpeed  OBJECT-TYPE
        SYNTAX  TrellixPortSpeed
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "See TrellixPortSpeed

                Default: fixed-hundred-Mbps (2)"
        ::= { respVirtualPortEntry 6 }

respVirtualPortPktDestination OBJECT-TYPE
        SYNTAX  INTEGER {
                switch (1),
                router (2)
        }

        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used when response ports are chosen for
                sending response packets. When router mode is chosen,
                packets will be sent to router with destination MAC as
                defined in intfRespMacAddress.

                Default value is switch (1)."
        ::= { respVirtualPortEntry 7 }

respVirtualPortMacAddress OBJECT-TYPE
        SYNTAX  MacAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Specifies the macaddress of the router to which the response
                packets have to be sent to."
        ::= { respVirtualPortEntry 8 }

-- Support for  respCUGEPortSpeed is deprecated in V-series sensors(VmIPS).
respVirtualCUGEPortSpeed  OBJECT-TYPE
        SYNTAX  TrellixCUGEType
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Only applicable to copper-gigabit-ethernet ports, to specify whether
                10mbps or 100mbps or 1-gbps or auto-neg. See TrellixCUGEType

                Default: auto-negotiate"
        ::= { respVirtualPortEntry 9 }

respVirtualAdditionalInfo  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "A textual string containing additional information about the response interface.
                This mib object will be available only on V-series sensors."
        ::= { respVirtualPortEntry 11 }


--
-- Interface Virtual Response Table
--
intfVirtualRespTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF IntfVirtualRespEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "Table containing entries for each interface port. The
                table describes how responses have to be sent in monitoring
                mode."
        ::= { responseVirtualPortGrp 2 }

intfVirtualRespEntry  OBJECT-TYPE
        SYNTAX  IntfVirtualRespEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                "Indexed by slotIndex/intfPortIndex"
        INDEX { slotIndex, intfPortIndex }
        ::= { intfVirtualRespTable 1 }

IntfVirtualRespEntry ::= SEQUENCE {
        intfVirtualRespType
                INTEGER,
        intfVirtualRespPortNo
                INTEGER
}

intfVirtualRespType OBJECT-TYPE
        SYNTAX  INTEGER {
                responsePort (1),
                inline (2)
        }

        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Setting this object to responsePort (2) causes responses
                to be sent via the response port. The response port no that
                needs to be used is specified with intfRespPortNo object.

                Setting this object to inline (3) causes responses to be
                sent inline. Note that in monitoring mode, responses can
                only be sent inline when the monitoring port is in
                half-duplex mode.

                Default action will be responsePort (1)."
        ::= { intfVirtualRespEntry 1 }

intfVirtualRespPortNo OBJECT-TYPE
        SYNTAX  INTEGER
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "Specifies the response port number that needs to be used
                for this monitoring port. The response ports are configured
                by respPortTable."
        ::= { intfVirtualRespEntry 2 }



--------------------------------------------------

--
-- mvxCfgGrp
--

mvxCfgGrp OBJECT IDENTIFIER ::= { ivSensorConfigurationMIB 56 }

mvxConnectionConfig OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to enable or disable the MVX integration
                Default: 2, disable"
        ::= { mvxCfgGrp 1 }


mvxIPAddressType OBJECT-TYPE
        SYNTAX  INTEGER {
                ip-v4 (4),
                ip-v6 (6)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IP address type of the
                 mgmt port at the MVX engine end"
        ::= { mvxCfgGrp 2 }

mvxBrokerIPv4Address  OBJECT-TYPE
        SYNTAX IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IPv4 address of the MVX engine.
                 The mvxBrokerIPv4Address would be zero if the current object is initialized"
        ::= { mvxCfgGrp 3 }

mvxBrokerIPv6Address  OBJECT-TYPE
        SYNTAX  Ipv6Address
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to configure the IPv6 address of the MVX engine.
                 The mvxBrokerIPv6Address would be zero if the current object is initialized"
        ::= { mvxCfgGrp 4 }

mvxUserName OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(1..80))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to send username for configured MVX engine.
              Default value is NULL"
        ::= { mvxCfgGrp 5 }

mvxPassword OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(1..80))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "This object is used to send password for configured MVX engine.
              Default value is NULL"
        ::= { mvxCfgGrp 6 }

mvxCertificateValidation  OBJECT-TYPE
        SYNTAX  INTEGER {
                     enable (1),
                     disable (2)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                "This object is used to indicate the MVX server certificate flag at
                 the sensor"
        ::= { mvxCfgGrp 7 }

mvxAuthStatus OBJECT-TYPE
	SYNTAX 	INTEGER {
		down(2),
		up (1)
	}
	MAX-ACCESS  read-only
	STATUS	current
	DESCRIPTION
		"This object is used to indicate the authentication status between
                 sensor and MVX engine "
	::= { mvxCfgGrp 8 }

mvxUseProxy OBJECT-TYPE
       SYNTAX 	INTEGER {
		disable(2),
		enable(1)
	}
	MAX-ACCESS  read-write
	STATUS	current
	DESCRIPTION
		"This object is used to indicate the configured proxy is used by the MVX engine or not "
	::= { mvxCfgGrp 9 }


--------------------------------------------------

END