summaryrefslogtreecommitdiff
path: root/MIBS/ubiquoss/UBQS-ENTITY-MIB
blob: 8c9a108a54dd83b7795cad0b07706320eb72a235 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
-- *****************************************************************
-- UBQS-ENTITY-MIB  : Ubiquoss FRU Control MIB file
--
-- June 2009, Hyung Eun Park
--
-- Copyright (c) 2009 by Ubiquoss, Corp.
-- All rights reserved.    
--
-- *****************************************************************
--

UBQS-ENTITY-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    NOTIFICATION-TYPE,
    Unsigned32,
    Integer32
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE,
    OBJECT-GROUP,
    NOTIFICATION-GROUP
        FROM SNMPv2-CONF
    TEXTUAL-CONVENTION,
    DisplayString,
    TimeStamp,
    TruthValue
        FROM SNMPv2-TC
    entPhysicalIndex,
    entPhysicalName,
    entPhysicalDescr,
    entPhysicalContainedIn
        FROM ENTITY-MIB
    ubiMgmtv2
        FROM UBQS-SMI;
  
  
ubiEntityMIB MODULE-IDENTITY
    LAST-UPDATED    "200906160000Z"
    ORGANIZATION 	"Ubiquoss Corp."
	CONTACT-INFO
		"	Ubiquoss
			Customer Service

		 Postal: 24F Milennium B/D,
		 	467-12, Dogok-Dong,
			GangNam-Gu, Seoul 135-270
			Korea

		   Tel: 82-2-2190-3100"     
    DESCRIPTION
        "The UBQS-ENTITY-MIB is used to monitor
        and configure operational status of 
        Field Replaceable Units (FRUs) and other managable 
        physical entities of the system listed in the 
        Entity-MIB (RFC 2737) entPhysicalTable."
    ::= { ubiMgmtv2 3 }


-- ***********************************************************   
-- TEXTUAL-CONVENTION
-- Define the composed syntax 
-- ***********************************************************

ModuleOperType ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "Operational module states.  Valid values are :

        	unknown(1)            Module is not in one of other states
         					  normal operational states:

        	ok(2)                 Module is operational.

        	disabled(3)           Module is administratively disabled.

        	selfTest(6)           Module is performing selfTest.


         failure states:

        	failed(7)              Module has failed due to some condition
                              not stated above.
                              
        	dormant(12)            Module is waiting for an external or
                              internal event to become operational.
		"
    SYNTAX          INTEGER  {
                        other(1),
                        ok(2),
                        disabled(3)
     }      

UbiSensorDataType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "sensor measurement data types.  valid values are:
        other(1):        a measure other than those listed below
        unknown(2):      unknown measurement, or 
                         arbitrary, relative numbers    
        volts(3):      electric potential
        amperes(4):      electric current
        celsius(5):      temperature
        dBm(6):         dB relative to 1mW of power     
        percentRH(8):    percent relative humidity
        rpm(9):         shaft revolutions per minute
        cmm(10),:        cubic meters per minute (airflow)
        truthvalue(11):  value takes { true(1), false(2) }
        specialEnum(12): value takes user defined enumerated values
        watts(13):        power
        hertz(14):        frequency
        "
    SYNTAX INTEGER {
        other(1),
        unknown(2),
        volts(3),
        amperes(4),   
        celsius(5),
        dBm(6),
        percentRH(8),
        rpm(9),
        cmm(10),
        truthvalue(11),
        specialEnum(12),
        watts(13),
        hertz(14)
    }          
    
UbiSensorDataScale ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "International System of Units (SI) prefixes."
    SYNTAX INTEGER {
        yocto(1),   -- 10^-24
        zepto(2),   -- 10^-21
        atto(3),    -- 10^-18
        femto(4),   -- 10^-15
        pico(5),    -- 10^-12
        nano(6),    -- 10^-9
        micro(7),   -- 10^-6
        milli(8),   -- 10^-3
        units(9),   -- 10^0
        kilo(10),   -- 10^3
        mega(11),   -- 10^6
        giga(12),   -- 10^9
        tera(13),   -- 10^12
        exa(14),    -- 10^15
        peta(15),   -- 10^18
        zetta(16),  -- 10^21
        yotta(17)   -- 10^24
    }

UbiSensorPrecision ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "When in the range 1 to 9, SensorPrecision is the number 
        of decimal places in the fractional part of 
        a SensorValue fixed-point number.  When in the range -8 to
        -1, SensorPrecision is the number of accurate digits in 
        a SensorValue fixed-point number.

        SensorPrecision is 0 for non-fixed-point numbers.

        Agent implementors must choose a value for SensorPrecision 
        so that the precision and accuracy of a SensorValue is 
        correctly indicated.

        For example, a temperature sensor that can measure 0o to 
        100o C in 0.1o increments, +/- 0.05o, would have a 
        SensorPrecision of 1, a SensorDataScale of units(0), and a 
        SensorValue ranging from 0 to 1000.  
        The SensorValue would be interpreted as (degrees C * 10).

        If that temperature sensor's precision were 0.1o but its 
        accuracy were only +/- 0.5o, then the SensorPrecision would 
        be 0. The SensorValue would be interpreted as degrees C.

        Another example: a fan rotation speed sensor that measures RPM 
        from 0 to 10,000 in 100 RPM increments, with an accuracy of 
        +50/-37 RPM, would have a SensorPrecision of -2, a 
        SensorDataScale of units(9), and a SensorValue ranging from 0 
        to 10000. The 10s and 1s digits of SensorValue would always 
        be 0.
        "
    SYNTAX INTEGER (-8..9)

UbiSensorValue_cisco ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "For sensors that measure voltsAC, voltsDC, 
        amperes, watts, hertz, celsius, cmm
        this item is a fixed point number ranging from 
        -999,999,999 to +999,999,999.  Use the value 
        -1000000000 to indicate underflow. Use the value 
        +1000000000 to indicate overflow.  Use SensorPrecision
        to indicate how many fractional digits the SensorValue
        has.


        For sensors that measure percentRH, this item
        is a number ranging from 0 to 100.

        For sensors that measure rpm, this item
        can take only nonnegative values, 0..999999999.

        For sensors of type truthvalue, this item 
        can take only two values: true(1), false(2).

        For sensors of type specialEnum, this item
        can take any value in the range (-1000000000..1000000000),
        but the meaning of each value is specific to the 
        sensor.

        For sensors of type other and unknown, 
        this item can take any value in the range 
        (-1000000000..1000000000), but the meaning of the values 
        are specific to the sensor.

        Use Entity-MIB entPhysicalTable.entPhysicalVendorType
        to learn about the sensor type.
    "
    SYNTAX INTEGER (-1000000000..1000000000)
 				         
 				         
UbiSensorValue ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Represent the sensor value"
    SYNTAX OCTET STRING 				         

    
UbiTcIdentifier ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        ""
    SYNTAX INTEGER {     
   		unknown(0),  
    	other(1),
		gbic(2),
		module(3),
		sfp(4),
		xbi(5),
		xenpak(6),
		xfp(7),
		xff(8),
		xfp_e(9),
		xpak(10),
		x2(11)
    }

    
UbiTcEncodingType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        ""
    SYNTAX INTEGER {
		unknown(0),     
		other(1),
		enc_64b(2),    
		enc_4b5b(3),		
		enc_8b10b(4),
		enc_sonet(5),
		enc_nrz(6),
		enc_rz(7),
		enc_manchester(8)
	}

UbiTcConnectorType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        ""
    SYNTAX INTEGER {
		unknown(0),     
		other(1),
		sc(2),
		fiber_style1_copper(3),
		fiber_stype2_copper(4),
		bnc_tnc(5),
		fiber_coaxial(6),
		fiberjack(7),     
		lc(8),
		mt_rj(9),
		sg(10),
		optical_pigtail(11),
		hssdc2(12),
		copper_pigtail(13)			
	}


   
-- ***********************************************************
-- ubiEntityMIB
-- *********************************************************** 

ubiEntityMIBObjects  			OBJECT IDENTIFIER		::= { ubiEntityMIB 1 }
ubiEntityMIBNotificationPrefix  OBJECT IDENTIFIER		::= { ubiEntityMIB 2 }
ubiEntityMIBConformance  		OBJECT IDENTIFIER	 	::= { ubiEntityMIB 3 }
        

ubiEntityNotificationEnables  	OBJECT IDENTIFIER		::= { ubiEntityMIBObjects 1 }
ubiExtSlot  					OBJECT IDENTIFIER		::= { ubiEntityMIBObjects 4 }
ubiTransceiver  				OBJECT IDENTIFIER		::= { ubiEntityMIBObjects 5 }

ubiFruNotifications  				OBJECT IDENTIFIER	 	::= { ubiEntityMIBNotificationPrefix 0 }
ubiEntitySensorNotifications  		OBJECT IDENTIFIER	 	::= { ubiEntityMIBNotificationPrefix 1 }

    	 
-- ***********************************************************
-- ubiEntityEnableFruControlNotification
-- ***********************************************************      


	ubiFRUControlEnabled OBJECT-TYPE
    	SYNTAX          TruthValue
    	MAX-ACCESS      read-write
    	STATUS          current
    	DESCRIPTION
        	"This variable indicates whether the system
        	produces the following notifications:
        	ubiEntityFRUInserted, ubiEntityFRURemoved.

        	A false value will prevent these notifications
       	 from being generated."
  	 	DEFVAL          { false } 
    	::= { ubiEntityNotificationEnables 1 }         
    	
  	ubiEntSensorThresholdNotificationEnabled OBJECT-TYPE
    	SYNTAX          TruthValue
    	MAX-ACCESS      read-write
    	STATUS          current
    	DESCRIPTION
        	"This variable indicates whether the system
        	produces the following notification:
        	ubiEntSensorThreshold.

        	A false value will prevent these notifications 
        	from being generated."
  	 	DEFVAL          { false } 
    	::= { ubiEntityNotificationEnables 2 }     

                                                                    
-- ***********************************************************
-- ubiEntityModuleTable
-- *********************************************************** 

	ubiModuleTable OBJECT-TYPE
    	SYNTAX          SEQUENCE OF UbiModuleEntry 
    	MAX-ACCESS      not-accessible
    	STATUS          current
    	DESCRIPTION
        	"This table contains one row per module entity."
    	::= { ubiEntityMIBObjects 2 }


	ubiModuleEntry OBJECT-TYPE
    	SYNTAX          UbiModuleEntry
    	MAX-ACCESS      not-accessible
    	STATUS          current
    	DESCRIPTION
        	"Information about a particular module entity."
    	INDEX           { entPhysicalIndex } 
    	::= { ubiModuleTable 1 }

	UbiModuleEntry ::= SEQUENCE {                  
		ubiModuleId								INTEGER,
		ubiModuleType							DisplayString,
        ubiModuleOperStatus             		ModuleOperType,
        ubiModuleStatusLastChangeTime   		TimeStamp,
        ubiModuleSerialNumber			  		DisplayString, 
        ubiModuleSlotNumber     				Integer32,
       	ubiModulePortNumber     				Integer32,
       	ubiModuleAction            				INTEGER,
       }
 
   	ubiModuleId OBJECT-TYPE
    	SYNTAX          INTEGER
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"The unique module ID." 
    	::= { ubiModuleEntry 1 }
 
  	ubiModuleType OBJECT-TYPE
    	SYNTAX          DisplayString
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"The textual type of this module." 
    	::= { ubiModuleEntry 2 }

	ubiModuleOperStatus OBJECT-TYPE
    	SYNTAX          ModuleOperType
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"The operational state of this module." 
    	::= { ubiModuleEntry 3 }
  
	ubiModuleStatusLastChangeTime OBJECT-TYPE
    	SYNTAX          TimeStamp
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
       		"The value of sysUpTime when ubiModuleOperStatus
        	is changed." 
    	::= { ubiModuleEntry 4 }     
    	
 	ubiModuleSerialNumber OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   
        	"The serial number of this module."
        ::= { ubiModuleEntry 5 }
 
  	ubiModuleSlotNumber OBJECT-TYPE
    	SYNTAX          Integer32
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"This value is determined by the number of slot 
        	where the module is located." 
    	::= { ubiModuleEntry 6 }   

 	ubiModulePortNumber OBJECT-TYPE
    	SYNTAX          Integer32
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"This value is determined by the number of port 
        	where the module is located." 
    	::= { ubiModuleEntry 7 }   

	ubiModuleAction 		OBJECT-TYPE
    	SYNTAX          INTEGER    	   
    	{   
    			other(1),
				reset(2)
    	}
    	MAX-ACCESS      read-write
    	STATUS          current
    	DESCRIPTION
        	"This object, when read, returns one of the
 			following results:
 	    		other(1):   module permanently enabled
 			
 			Setting this object to one of the acceptable values 
 			gives the following results:
 	  			other(1):  gives an error
 	  			reset(2):  resets the module's control logic
 				Setting this object to any other values results in
 				an error." 
    	::= { ubiModuleEntry 8 }
 
 
 
-- ***********************************************************
-- ubiSlotEntity
-- ***********************************************************   

	ubiSlotTable OBJECT-TYPE
    	SYNTAX          SEQUENCE OF UbiSlotEntry
    	MAX-ACCESS      not-accessible
    	STATUS          current
    	DESCRIPTION
        	"This table contains one row per slot entity."
    	::= { ubiEntityMIBObjects 3 }

	ubiSlotEntry OBJECT-TYPE
    	SYNTAX          UbiSlotEntry
    	MAX-ACCESS      not-accessible
    	STATUS          current
    	DESCRIPTION
        	"Information about a particular slot entity."
    	INDEX           { entPhysicalIndex } 
    	::= { ubiSlotTable 1 }

	UbiSlotEntry ::= SEQUENCE { 
		ubiSlotModuleId					INTEGER,       
		ubiSlotId						INTEGER,  
		ubiSlotType						DisplayString,
		ubiSlotOperStatus 			 	ModuleOperType,
       	ubiSlotPortNumber     			Integer32,
       	ubiSlotSerialNumber             DisplayString
	}                       
	
 	ubiSlotModuleId OBJECT-TYPE
    	SYNTAX          INTEGER
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"The unique module ID." 
    	::= { ubiSlotEntry 1 } 
 
  	ubiSlotId OBJECT-TYPE
    	SYNTAX          INTEGER
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"The unique slot ID." 
    	::= { ubiSlotEntry 2 }
 
  	ubiSlotType OBJECT-TYPE
    	SYNTAX          DisplayString
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"The textual type of this slot." 
    	::= { ubiSlotEntry 3 }

	ubiSlotOperStatus OBJECT-TYPE
    	SYNTAX          ModuleOperType 
    	MAX-ACCESS      read-only
   	 	STATUS          current
    	DESCRIPTION
        	"The status of this slot." 
    	::= { ubiSlotEntry 4 }

 	ubiSlotPortNumber OBJECT-TYPE
    	SYNTAX          Integer32
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"This value is determined by the number of port 
        	where the slot is located." 
    	::= { ubiSlotEntry 5 }   
   
 	ubiSlotSerialNumber OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION   
        	"The serial number of this slot."
        ::= { ubiSlotEntry 6 }
                 
                 
-- ***********************************************************
-- ubiExtSlotTable
-- *********************************************************** 

 	ubiIEEE1588SlotOperStatus OBJECT-TYPE
    	SYNTAX          INTEGER {           
    		equip(1),
    		unequip(2)
    	}
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"The operational status of the slot for 
        	IEEE 1588 specification." 
    	::= { ubiExtSlot 1 }   
                 

 	ubiMngSlotOperStatus OBJECT-TYPE
    	SYNTAX          INTEGER {           
    		equip(1),
    		unequip(2)
    	}
    	MAX-ACCESS      read-only
    	STATUS          current
    	DESCRIPTION
        	"The operational status of the slot for 
        	mng specification." 
    	::= { ubiExtSlot 2 }   
                 
-- ***********************************************************
-- ubiTransceiver
-- ***********************************************************
  
 	ubiTransceiverMonitoring OBJECT-TYPE
    	SYNTAX          TruthValue
     	MAX-ACCESS      read-write
    	STATUS          current    
    	DESCRIPTION
        "This variable indicates whether the system produces 
        the log and notification for transceiver sensor."
	   	::= { ubiTransceiver 3 }         
	   	
	   	
-- ***********************************************************
-- ubiEntitySensorTable
-- ***********************************************************
  
	ubiEntitySensorTable OBJECT-TYPE
    	SYNTAX          SEQUENCE OF UbiEntitySensorEntry 
    	MAX-ACCESS      not-accessible
    	STATUS          current
    	DESCRIPTION
        	"This table contains objects which provide information 
        	 about the transceiver sensor of physical entity."
    	::= { ubiTransceiver 1 }

	ubiEntitySensorEntry OBJECT-TYPE
    	SYNTAX          UbiEntitySensorEntry
    	MAX-ACCESS      not-accessible
    	STATUS          current
    	DESCRIPTION
        	"An entry containing management information applicable 
        	to the transceiver sensor of a particular physical entity."
    	INDEX           { entPhysicalIndex  } 
    	::= { ubiEntitySensorTable 1 }
                                                
	UbiEntitySensorEntry ::= SEQUENCE {            
			ubiEntSensorType							UbiSensorDataType,     
			ubiEntSensorScale							UbiSensorDataScale,
			ubiEntSensorValue                       	UbiSensorValue,
			ubiEntSensorEventStatus 					INTEGER,
			ubiEntSensorEventUpdateTime					TimeStamp,		
			ubiEntSensorAlarmHighThreshold				UbiSensorValue,   
			ubiEntSensorWarningHighThreshold			UbiSensorValue,    
			ubiEntSensorWarningLowThreshold				UbiSensorValue,
			ubiEntSensorAlarmLowThreshold				UbiSensorValue,			
			--ubiEntSensorPrecision 					UbiSensorPrecision,    
			ubiEntSensorName							DisplayString

	}
  
 	ubiEntSensorType OBJECT-TYPE
    	SYNTAX          UbiSensorDataType
     	MAX-ACCESS      read-only
    	STATUS          current    
    	DESCRIPTION
        "This variable indicates the type of data reported 
         by the entSensorValue.  
         valid values are:
	        other(1):        a measure other than those listed below
	        unknown(2):      unknown measurement, or 
	                         arbitrary, relative numbers    
	        voltsAC(3):      electric potential
	        voltsDC(4):      electric potential
	        amperes(5):      electric current
	        celsius(6):      temperature
	        dBm(7):         dB relative to 1mW of power     
		"
	   	::= { ubiEntitySensorEntry 1 }   
  
  	ubiEntSensorScale OBJECT-TYPE
    	SYNTAX          UbiSensorDataScale
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates the exponent to apply
            to sensor values reported by entSensorValue." 
    	::= { ubiEntitySensorEntry 2 }    
 
 -- 	ubiEntSensorPrecision OBJECT-TYPE
 --   	SYNTAX          UbiSensorPrecision
 --   	MAX-ACCESS      read-only
 --   	STATUS          current
 --  		DESCRIPTION
 --       	"" 
 --   	::= { ubiEntitySensorEntry 3 }  

 
  	ubiEntSensorValue OBJECT-TYPE
    	SYNTAX          UbiSensorValue
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"This variable reports the most recent measurement seen
             by the sensor." 
    	::= { ubiEntitySensorEntry 3 } 
 
 	ubiEntSensorEventStatus OBJECT-TYPE
    	SYNTAX          INTEGER {     
    		none(0),
    	 	normal(1),
    	 	highAlarm(2),   
     	 	highWarning(3),
     	 	lowWarning(4),  
    	 	lowAlarm(5)
       	}
    	MAX-ACCESS      read-only
    	STATUS          current    
    	DESCRIPTION
        	"This variable indicates the present 
        	current event status of the sensor."
	   	::= { ubiEntitySensorEntry 4 }    

 
  	ubiEntSensorEventUpdateTime OBJECT-TYPE
    	SYNTAX          TimeStamp
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"The value of sysUpTime when the status of 
        	entity sensor is changed." 
    	::= { ubiEntitySensorEntry 5 } 

   	ubiEntSensorAlarmHighThreshold OBJECT-TYPE
        SYNTAX			UbiSensorValue
        MAX-ACCESS      read-write
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates the value of 
        	the high alarm threshold."
       	::= { ubiEntitySensorEntry 6 }    				 
  
  
   	ubiEntSensorWarningHighThreshold OBJECT-TYPE
        SYNTAX			UbiSensorValue
        MAX-ACCESS      read-write
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates the value of 
        	the high warning threshold."
       	::= { ubiEntitySensorEntry 7 }    				 

   	ubiEntSensorWarningLowThreshold OBJECT-TYPE
        SYNTAX			UbiSensorValue
        MAX-ACCESS      read-write
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates the value of 
        	the low warning threshold."
       	::= { ubiEntitySensorEntry 8 }   

   	ubiEntSensorAlarmLowThreshold OBJECT-TYPE
        SYNTAX			UbiSensorValue
        MAX-ACCESS      read-write
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates the value of 
        	the low alarm threshold."
       	::= { ubiEntitySensorEntry 9 }    
       	
   	ubiEntSensorName OBJECT-TYPE
        SYNTAX			DisplayString
        MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates the name of 
        	 the sensor entity."
       	::= { ubiEntitySensorEntry 10 }    
                                        
-- ***********************************************************
-- ubiTransceiverInfoTable
-- ***********************************************************
  
	ubiTransceiverInfoTable OBJECT-TYPE
    	SYNTAX          SEQUENCE OF UbiTransceiverInfoEntry 
    	MAX-ACCESS      not-accessible
    	STATUS          current
    	DESCRIPTION
        	"This table contains objects which provide information 
        	 about the transceiver of physical entity."
    	::= { ubiTransceiver 2 }

	ubiTransceiverInfoEntry OBJECT-TYPE
    	SYNTAX          UbiTransceiverInfoEntry
    	MAX-ACCESS      not-accessible
    	STATUS          current
    	DESCRIPTION
        	"An entry containing management information applicable 
        	to the transceiver of a particular physical entity."
    	INDEX           { entPhysicalIndex  } 
    	::= { ubiTransceiverInfoTable 1 }
                                                
	UbiTransceiverInfoEntry ::= SEQUENCE {            
			ubiTcIdentifier           			UbiTcIdentifier,
			ubiTcVendorOUI						DisplayString,
			ubiTcVendorName						DisplayString,
			ubiTcVendorPartNumber				DisplayString,
			ubiTcVendorRevisionLevel			DisplayString,	
			ubiTcVendorSerialNumber				DisplayString,	
			ubiTcVendorManufacturingDate		DisplayString,	
			ubiTcWaveLength						Integer32,
			ubiTcConnector			    		UbiTcConnectorType,
			ubiTcLength							Integer32,   
	}
  
 	ubiTcIdentifier OBJECT-TYPE
    	SYNTAX          UbiTcIdentifier
     	MAX-ACCESS      read-only
    	STATUS          current    
    	DESCRIPTION
		"This variable indicates the transceiver indentifier.
		 valid value are:
		      	unknown(0),  
		    	other(1),
				gbic(2),
				module(3),
				sfp(4),
				xbi(5),
				xenpak(6),
				xfp(7),
				xff(8),
				xfp_e(9),
				xpak(10),
				x2(11)
		"
	   	::= { ubiTransceiverInfoEntry 1 }   
  
  	ubiTcVendorOUI OBJECT-TYPE
    	SYNTAX          DisplayString
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION      
 			"This variable indicates a textual string containing 
			information about the IEEE company ID of transceiver vendor"  
    	::= { ubiTransceiverInfoEntry 2 }    

  	ubiTcVendorName OBJECT-TYPE
    	SYNTAX          DisplayString
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"A textual string containing information about the
            transceiver name." 
    	::= { ubiTransceiverInfoEntry 3 }   

  	ubiTcVendorPartNumber OBJECT-TYPE
    	SYNTAX          DisplayString
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"A textual string containing information about the
            part number of the transceiver." 
    	::= { ubiTransceiverInfoEntry 4 }   
 
  	ubiTcVendorRevisionLevel OBJECT-TYPE
    	SYNTAX          DisplayString
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
       	    "A textual string containing information about the
             revision level of the transceiver part number." 
    	::= { ubiTransceiverInfoEntry 5 }   
 
  	ubiTcVendorSerialNumber OBJECT-TYPE
    	SYNTAX          DisplayString
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
			"This variable indicates a textual string containing 
			information about the transceiver serial number."   	
       	::= { ubiTransceiverInfoEntry 6 }  
                                                 
  	ubiTcVendorManufacturingDate OBJECT-TYPE
    	SYNTAX          DisplayString
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates a manufacturing date 
        	of transceiver"
    	::= { ubiTransceiverInfoEntry 7 }    
       
  	ubiTcWaveLength OBJECT-TYPE
    	SYNTAX          Integer32      
    	UNITS			"Nanometer"
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates a wave length 
        	of transceiver." 
    	::= { ubiTransceiverInfoEntry 8 }        
       
  	ubiTcConnector OBJECT-TYPE
    	SYNTAX          UbiTcConnectorType
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates a connector type 
        	of transceiver."  
    	::= { ubiTransceiverInfoEntry 9 }    

  	ubiTcLength OBJECT-TYPE
    	SYNTAX          Integer32   
    	UNITS			"Meter"
    	MAX-ACCESS      read-only
    	STATUS          current
   		DESCRIPTION
        	"This variable indicates a length 
        	of transceiver." 
    	::= { ubiTransceiverInfoEntry 10 }    
                
                                                 
-- ***********************************************************
-- ubiEntityFRUMIBNotificationPrefix
-- ***********************************************************  
	ubiFRUInserted NOTIFICATION-TYPE
    	OBJECTS         { 
    					entPhysicalContainedIn,    
    					entPhysicalDescr,
    				  	entPhysicalName	  	 
    					}
    	STATUS          current
    	DESCRIPTION
        	"The ubiEntityFRUInserted notification indicates that a FRU was
        	inserted. The varbind for this notification indicates the
        	entPhysicalIndex of the inserted FRU, and the entPhysicalIndex
        	of the FRU's container."
   		::= { ubiFruNotifications 1 }

	ubiFRURemoved NOTIFICATION-TYPE
    	OBJECTS         { 
    					entPhysicalContainedIn,    
    					entPhysicalDescr,
    				  	entPhysicalName	  
    				    }
    	STATUS          current
    	DESCRIPTION
       		"The ubiEntityFRURemoved notification indicates that a FRU was
        	removed. The varbind for this notification indicates the
        	entPhysicalIndex of the removed FRU, and the entPhysicalIndex
        	of the FRU's container."
   		::= { ubiFruNotifications 2 }
 
-- ***********************************************************
-- ubiDdmMIBNotificationPrefix
-- ***********************************************************       
         
	ubiEntSensorThreshold NOTIFICATION-TYPE
    	OBJECTS {
    			entPhysicalDescr,  
    			ubiEntSensorEventStatus,
    			ubiEntSensorValue,       
    			ubiEntSensorAlarmHighThreshold,      
       			ubiEntSensorWarningHighThreshold,
    			ubiEntSensorWarningLowThreshold, 
    			ubiEntSensorAlarmLowThreshold, 
    	}             
    	STATUS          current
    	DESCRIPTION
        	"The ubiEntSensorThreshold notification indicates that 
        	the status of transceiver sensor was changed."
   	::= { ubiEntitySensorNotifications 1 }
          
 
-- ***********************************************************
-- ubiEntityMIBConformance
-- ***********************************************************  

-- conformance information

ubiEntityMIBCompliances  OBJECT IDENTIFIER		::= { ubiEntityMIBConformance 1 }
ubiEntityMIBGroups  OBJECT IDENTIFIER			::= { ubiEntityMIBConformance 2 }


--
-- compliance statements
--
	ubiEntityMIBCompliance MODULE-COMPLIANCE
    	STATUS          current
    	DESCRIPTION
        	"An Entity-MIB implementation can implement this group to
        	provide FRU status and control."
   	 	MODULE          -- this module
    	MANDATORY-GROUPS {
    					ubiEntityMIBModuleGroup,
    					ubiEntityMIBSlotGroup,
                        ubiEntityMIBNotificationGroup,
                        ubiEntiryMIBIEEE1588SlotGroup,
                        ubiEntityMIBTransceiverGroup
                        }

    	GROUP           ubiEntityMIBModuleGroup
    	DESCRIPTION
        	"The ubiEntityMIBModuleGroup must be implemented for
        	FRUs that are of module type."

    	GROUP           ubiEntityMIBSlotGroup
    	DESCRIPTION
        	"The ubiEntityMIBSlotGroup must be
        	implemented for FRUs that of slot type"
        	   
    	GROUP           ubiEntityMIBNotificationGroup
    	DESCRIPTION
        	"The ubiEntityMIBNotificationGroup must be
        	implemented for FRUs that have notification"           	
        
        GROUP			ubiEntiryMIBIEEE1588SlotGroup
        DESCRIPTION
        	"The ubiEntiryMIBIEEE1588SlotGroup must be
        	 implemented for FRUs that of slot for 
        	 IEEE 1588 specification."     
        GROUP		ubiEntityMIBTransceiverGroup
        DESCRIPTION
        	"The ubiEntityMIBTransceiverGroup must be implemented 
        	for transceiver."
    	::= { ubiEntityMIBCompliances 1 }

-- units of conformance

	ubiEntityMIBModuleGroup OBJECT-GROUP
    	OBJECTS         {
                        ubiEntityModuleAdminStatus,
                        ubiEntityModuleOperStatus,
                        ubiEntityModuleStatusLastChangeTime
                    	}
    	STATUS          current
    	DESCRIPTION
        	"The collection of objects which are used to get the
        	operational state and redundancy state of the modules"
    	::= { ubiEntityMIBGroups 1 }

	ubiEntitySlotGroup NOTIFICATION-GROUP
   		NOTIFICATIONS    { ubiEntitySlotOperStatus }
    	STATUS          current
    	DESCRIPTION
        	"The collection of objects which are used to get the
        	operational state and redundancy state of the slot."
    	::= { ubiEntityMIBGroups 2 }    
 
	ubiEntityMIBNotificationGroup OBJECT-GROUP
    	OBJECTS         { 
      						ubiEntityEnableFruControlNotification,
    						ubiEntityFRUInserted,
    					  	ubiEntityFRURemoved
    					}
    	STATUS          current
    	DESCRIPTION
        	"TThe collection of objects which are 
        	used to send a notification."
    	::= { ubiEntityMIBGroups 3 }


	ubiEntiryMIBIEEE1588SlotGroup   OBJECT-GROUP
    	OBJECTS         { 
      						ubiIEEE1588SlotOperStatus
      		}
    	STATUS          current
    	DESCRIPTION
        	"The collection of objects which are used to get the
        	operational state of the slot for IEEE 1588."
    	::= { ubiEntityMIBGroups 4 }

	
	ubiEntityMIBTransceiverGroup    OBJECT-GROUP
    	OBJECTS         { 
     		ubiEntSensorType,     
			ubiEntSensorScale,
			ubiEntSensorValue,
			ubiEntSensorEventStatus,
			ubiEntSensorEventUpdateTime,		
			ubiEntSensorAlarmHighThreshold,   
			ubiEntSensorWarningHighThreshold,    
			ubiEntSensorWarningLowThreshold	,
			ubiEntSensorAlarmLowThreshold,	      		
			ubiTcIdentifier,
			ubiTcVendorOUI,
			ubiTcVendorName,
			ubiTcVendorPartNumber,
			ubiTcVendorRevisionLevel,	
			ubiTcVendorSerialNumber,	
			ubiTcVendorManufacturingDate,	
			ubiTcWaveLength	,
			ubiTcConnector,
			ubiTcLength
		}
    	STATUS          current
    	DESCRIPTION
        	"The collection of objects which are used to get the
        	information of transceiver."
    	::= { ubiEntityMIBGroups 5 }


END