summaryrefslogtreecommitdiff
path: root/MIBS/wti/WTI-MPC-MIB
blob: db9abec316ca494978eea74ca76aebcd81c62a2e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
 --
 -- Copyright(C) 2008 Western Telematic, Inc.
 --
        WTI-MPC-MIB DEFINITIONS ::= BEGIN

        IMPORTS
        MODULE-IDENTITY, NOTIFICATION-TYPE,
        OBJECT-TYPE, enterprises FROM SNMPv2-SMI
        DisplayString FROM SNMPv2-TC;
        westernTelematic OBJECT IDENTIFIER ::= { enterprises 2634 }

        wti MODULE-IDENTITY
                LAST-UPDATED "200812171530Z" -- 17 Dec 2008
                ORGANIZATION "Western Telematic, Inc."
                CONTACT-INFO
                "Western Telematic, Inc.
		5 Sterling
		Irvine, Ca 92618
		Email: anthonyb@wti.com"
                DESCRIPTION
                        "This is the MIB module for the MPC"

                REVISION "200812171530Z" -- 17 Dec 2008

                DESCRIPTION
                        "V3.00 for the MPC 1.60"

        ::= { westernTelematic 3 }

        --
        -- System Tables
        --

        systemTables OBJECT IDENTIFIER ::= { wti 100 }
        --
        -- Plug Table
        --

        plugTable OBJECT-TYPE
                SYNTAX SEQUENCE OF PlugEntry
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "A table of plugs."
        ::= { systemTables 200 }

        plugEntry OBJECT-TYPE
                SYNTAX PlugEntry
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "Row definition for the plug table."
                INDEX { plugIndex }
        ::= { plugTable 1 }

        PlugEntry ::= SEQUENCE {
                plugIndex INTEGER,
                plugID DisplayString,
                plugStatus INTEGER,
                plugAction INTEGER,
                plugName DisplayString
        }

        plugIndex OBJECT-TYPE
                SYNTAX INTEGER (0..80)
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "Index for the plug table."
        ::= { plugEntry 1 }

        plugID OBJECT-TYPE
                SYNTAX DisplayString(SIZE(9..11))
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The ID of the plug."
        ::= { plugEntry 2 }

        plugStatus OBJECT-TYPE
                SYNTAX INTEGER (0..1)
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Plug status"
        ::= { plugEntry 3 }

        plugAction OBJECT-TYPE
                SYNTAX INTEGER (0..8)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Plug action"
        ::= { plugEntry 4 }

        plugName OBJECT-TYPE
                SYNTAX DisplayString
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The Name of the plug."
        ::= { plugEntry 5 }

        --
        -- Plug Group Table
        --

        plugGroupTable OBJECT-TYPE
                SYNTAX SEQUENCE OF PlugGroupEntry
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "A table of plug groups."
        ::= { systemTables 300 }

        plugGroupEntry OBJECT-TYPE
                SYNTAX PlugGroupEntry
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "Row definition for the plug group table."
                INDEX { plugGroupIndex }
        ::= { plugGroupTable 1 }

        PlugGroupEntry ::= SEQUENCE {
                plugGroupIndex INTEGER,
                plugGroupName DisplayString,
                plugGroupAction INTEGER
        }

        plugGroupIndex OBJECT-TYPE
                SYNTAX INTEGER (0..54)
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "Index for the plug group table."
        ::= { plugGroupEntry 1 }

        plugGroupName OBJECT-TYPE
                SYNTAX DisplayString(SIZE(1..24))
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The name of the plug group."
        ::= { plugGroupEntry 2 }

        plugGroupAction OBJECT-TYPE
                SYNTAX INTEGER (0..8)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Plug group action"
        ::= { plugGroupEntry 3 }

        --
        -- User Table
        --

        userTable OBJECT-TYPE
                SYNTAX SEQUENCE OF UserEntry
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "A table of users."
        ::= { systemTables 400 }

        userEntry OBJECT-TYPE
                SYNTAX UserEntry
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "Row definition for the user table."
                INDEX { userIndex }
        ::= { userTable 1 }

        UserEntry ::= SEQUENCE {
                userIndex INTEGER,
                userName DisplayString,
                userPasswd DisplayString,
                userAccessLevel INTEGER,
                userPortAccess DisplayString,
                userLocalAccess DisplayString,
                userAux1Access DisplayString,
                userAux2Access DisplayString,
                userAux3Access DisplayString,
                userGroupAccess DisplayString,
                userSerialAccess INTEGER,
                userTelnetSshAccess INTEGER,
                userWebAccess INTEGER,
                userCurrentPowerMetering INTEGER,
                userCallbackNum DisplayString,
                userSubmit INTEGER
        }

        userIndex OBJECT-TYPE
                SYNTAX INTEGER (0..128)
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "Index for the user table."
        ::= { userEntry 1 }

        userName OBJECT-TYPE
                SYNTAX DisplayString(SIZE(0..32))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "The name of the user."
        ::= { userEntry 2 }

        userPasswd OBJECT-TYPE
                SYNTAX DisplayString(SIZE(1..16))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "The password of the user."
        ::= { userEntry 3 }

        userAccessLevel OBJECT-TYPE
                SYNTAX INTEGER (0..3)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Users access level"
        ::= { userEntry 4 }

        userPortAccess OBJECT-TYPE
                SYNTAX DisplayString(SIZE(1..5))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to ports."
        ::= { userEntry 5 }

        userLocalAccess OBJECT-TYPE
                SYNTAX DisplayString(SIZE(1..20))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to LOCAL plugs."
        ::= { userEntry 6 }

        userAux1Access OBJECT-TYPE
                SYNTAX DisplayString(SIZE(1..20))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to AUX1 plugs."
        ::= { userEntry 7 }

        userAux2Access OBJECT-TYPE
                SYNTAX DisplayString(SIZE(1..20))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to AUX2 plugs."
        ::= { userEntry 8 }

        userAux3Access OBJECT-TYPE
                SYNTAX DisplayString(SIZE(1..20))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to AUX3 plugs."
        ::= { userEntry 9 }

        userGroupAccess OBJECT-TYPE
                SYNTAX DisplayString(SIZE(1..54))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to plug groups."
        ::= { userEntry 10 }

        userSerialAccess OBJECT-TYPE
                SYNTAX INTEGER (0..1)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to serial interface."
        ::= { userEntry 11 }

        userTelnetSshAccess OBJECT-TYPE
                SYNTAX INTEGER (0..1)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to Telnet/SSH interface."
        ::= { userEntry 12 }

        userWebAccess OBJECT-TYPE
                SYNTAX INTEGER (0..1)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to web interface."
        ::= { userEntry 13 }

        userCurrentPowerMetering OBJECT-TYPE
                SYNTAX INTEGER (0..1)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Access to Current/Power Metering."
        ::= { userEntry 15 }

        userCallbackNum OBJECT-TYPE
                SYNTAX DisplayString(SIZE(0..32))
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Callback number."
        ::= { userEntry 16 }

        userSubmit OBJECT-TYPE
                SYNTAX INTEGER (0..1)
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                        "Submit changes to user."
        ::= { userEntry 31 }

        --
        -- Environment Tables
        --

        environmentTables OBJECT IDENTIFIER ::= { wti 200 }

        environmentUnitTable OBJECT-TYPE
                SYNTAX SEQUENCE OF EnvironmentUnitEntry
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "A table of environment status for units."
        ::= { environmentTables 10 }

        environmentUnitEntry OBJECT-TYPE
                SYNTAX EnvironmentUnitEntry
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "Row definition for the environment unit table."
                INDEX { environmentUnitIndex }
        ::= { environmentUnitTable 1 }

        EnvironmentUnitEntry ::= SEQUENCE {
                environmentUnitIndex INTEGER,
                environmentUnitName DisplayString,
                environmentUnitTemperature INTEGER,
                environmentUnitCurrentA INTEGER,
                environmentUnitVoltageA INTEGER,
                environmentUnitPowerA INTEGER,
                environmentUnitCurrentB INTEGER,
                environmentUnitVoltageB INTEGER,
                environmentUnitPowerB INTEGER,
                environmentUnitCurrentC INTEGER,
                environmentUnitVoltageC INTEGER,
                environmentUnitPowerC INTEGER,
                environmentUnitCurrentD INTEGER,
                environmentUnitVoltageD INTEGER,
                environmentUnitPowerD INTEGER
        }

        environmentUnitIndex OBJECT-TYPE
                SYNTAX INTEGER (0..3)
                MAX-ACCESS not-accessible
                STATUS current
                DESCRIPTION
                        "Index for the environment unit table."
        ::= { environmentUnitEntry 1 }

        environmentUnitName OBJECT-TYPE
                SYNTAX DisplayString(SIZE(0..10))
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The name of the unit."
        ::= { environmentUnitEntry 2 }

        environmentUnitTemperature OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The name of the unit."
        ::= { environmentUnitEntry 3 }

        environmentUnitCurrentA OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The number of amps in branch A for unit (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentUnitEntry 4 }

        environmentUnitVoltageA OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The voltage of branch A for unit."
        ::= { environmentUnitEntry 5 }

        environmentUnitPowerA OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The number of watts used by branch A for unit."
        ::= { environmentUnitEntry 6 }

        environmentUnitCurrentB OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The number of amps in branch B for unit (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentUnitEntry 7 }

        environmentUnitVoltageB OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The voltage of branch B for unit."
        ::= { environmentUnitEntry 8 }

        environmentUnitPowerB OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The number of watts used by branch b for unit."
        ::= { environmentUnitEntry 9 }

        environmentUnitCurrentC OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The number of amps in branch C for unit (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentUnitEntry 10 }

        environmentUnitVoltageC OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The voltage of branch C for unit."
        ::= { environmentUnitEntry 11 }

        environmentUnitPowerC OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The number of watts used by branch c for unit."
        ::= { environmentUnitEntry 12 }

        environmentUnitCurrentD OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The number of amps in branch D for unit (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentUnitEntry 13 }

        environmentUnitVoltageD OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The voltage of branch D for unit."
        ::= { environmentUnitEntry 14 }

        environmentUnitPowerD OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The number of watts used by branch d for unit."
        ::= { environmentUnitEntry 15 }

        environmentBranchATotalCurrent OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total Current on BRANCH A (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentTables 20 }

        environmentBranchATotalPower OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total Power on BRANCH A."
        ::= { environmentTables 30 }

        environmentBranchBTotalCurrent OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total Current on BRANCH B (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentTables 40 }

        environmentBranchBTotalPower OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total Power on BRANCH B."
        ::= { environmentTables 50 }

        environmentBranchCTotalCurrent OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total Current on BRANCH C (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentTables 51 }

        environmentBranchCTotalPower OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total Power on BRANCH C."
        ::= { environmentTables 52 }

        environmentBranchDTotalCurrent OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total Current on BRANCH D (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentTables 53 }

        environmentBranchDTotalPower OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total Power on BRANCH D."
        ::= { environmentTables 54 }

        environmentSystemTotalCurrent OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total current for system  (In tenths of amps, divide by 10 for value in amps)."
        ::= { environmentTables 60 }

        environmentSystemTotalPower OBJECT-TYPE
                SYNTAX INTEGER
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Total power on system."
        ::= { environmentTables 70 }

        environmentMonthlyPowerLog OBJECT-TYPE
                SYNTAX DisplayString
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "The monthly power usage log"
        ::= { environmentTables 80 }

        --
        -- Traps
        --

        wtiTraps OBJECT IDENTIFIER ::= { wti 300 }

        -- Trap Info

        trapInfo OBJECT-TYPE
                SYNTAX DisplayString
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                        "Alarm information"
        ::= { wtiTraps 1 }

        -- Test Traps

        testTraps OBJECT IDENTIFIER ::= { wtiTraps 2}

        testTrap TRAP-TYPE
                ENTERPRISE testTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "A test trap"
        ::= 1

        -- Alarm Traps

        overCurrentInitialTraps OBJECT IDENTIFIER ::= { wtiTraps 4}

        overCurrentInitialSetTrap TRAP-TYPE
                ENTERPRISE overCurrentInitialTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Over Current Initial Alarm"
        ::= 1

        overCurrentInitialClearTrap TRAP-TYPE
                ENTERPRISE overCurrentInitialTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Over Current Initial Alarm (Clear)"
        ::= 2

        overCurrentCriticalTraps OBJECT IDENTIFIER ::= { wtiTraps 5}

        overCurrentCriticalSetTrap TRAP-TYPE
                ENTERPRISE overCurrentCriticalTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Over Current Critical Alarm"
        ::= 1

        overCurrentCriticalClearTrap TRAP-TYPE
                ENTERPRISE overCurrentCriticalTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Over Current Critical Alarm (Clear)"
        ::= 2

        overTemperatureInitialTraps OBJECT IDENTIFIER ::= { wtiTraps 6}

        overTemperatureInitialSetTrap TRAP-TYPE
                ENTERPRISE overTemperatureInitialTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Over Temperature Initial Alarm"
        ::= 1

        overTemperatureInitialClearTrap TRAP-TYPE
                ENTERPRISE overTemperatureInitialTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Over Temperature Initial Alarm (Clear)"
        ::= 2

        overTemperatureCriticalTraps OBJECT IDENTIFIER ::= { wtiTraps 7}

        overTemperatureCriticalSetTrap TRAP-TYPE
                ENTERPRISE overTemperatureCriticalTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Over Temperature Critical Alarm"
        ::= 1

        overTemperatureCriticalClearTrap TRAP-TYPE
                ENTERPRISE overTemperatureCriticalTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Over Temperature Critical Alarm (Clear)"
        ::= 2

        circuitBreakerOpenTraps OBJECT IDENTIFIER ::= { wtiTraps 8}

        circuitBreakerOpenSetTrap TRAP-TYPE
                ENTERPRISE circuitBreakerOpenTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Circuit Breaker Open Alarm"
        ::= 1

        circuitBreakerOpenClearTrap TRAP-TYPE
                ENTERPRISE circuitBreakerOpenTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Circuit Breaker Open Alarm (Clear)"
        ::= 2

        lostCommTraps OBJECT IDENTIFIER ::= { wtiTraps 9}

        lostCommSetTrap TRAP-TYPE
                ENTERPRISE lostCommTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Lost Communication with AUX Unit"
        ::= 1

        lostCommClearTrap TRAP-TYPE
                ENTERPRISE lostCommTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Lost Communication with AUX Unit (Clear)"
        ::= 2

        lostVoltageTraps OBJECT IDENTIFIER ::= { wtiTraps 10}

        lostVoltageSetTrap TRAP-TYPE
                ENTERPRISE lostVoltageTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Lost Voltage (Line In)"
        ::= 1

        lostVoltageClearTrap TRAP-TYPE
                ENTERPRISE lostVoltageTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Lost Voltage (Line In) (Clear)"
        ::= 2

        pingNoAnswerTraps OBJECT IDENTIFIER ::= { wtiTraps 11}

        pingNoAnswerSetTrap TRAP-TYPE
                ENTERPRISE pingNoAnswerTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Ping No Answer"
        ::= 1

        pingNoAnswerClearTrap TRAP-TYPE
                ENTERPRISE pingNoAnswerTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Ping No Answer (Clear)"
        ::= 2

        lockoutTraps OBJECT IDENTIFIER ::= { wtiTraps 12}

        lockoutSetTrap TRAP-TYPE
                ENTERPRISE lockoutTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Invalid Access Lockout"
        ::= 1

        lockoutClearTrap TRAP-TYPE
                ENTERPRISE lockoutTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Invalid Access Lockout (Clear)"
        ::= 2

        powercycleTraps OBJECT IDENTIFIER ::= { wtiTraps 13}

        powercycleSetTrap TRAP-TYPE
                ENTERPRISE powercycleTraps
                VARIABLES {
                trapInfo
                }
                DESCRIPTION
                        "Power Cycle"
        ::= 1

 END