mibs/MIBS/ccpower/CCPOWER-MIB

1550 lines
51 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--
-- C&C Power DC_SYSTEM MIB
-- Management Information Base for SNMP Network Management
--
-- Copyright 2004 C&C Power, Inc.
--
-- C&C Power shall not be liable for technical or
-- editorial errors or omissions contained herein. The information in
-- this document is provided "as is" without warranty of any kind and
-- is subject to change without notice. The warranties for C&C Power products
-- are set forth in the express limited warranty statements
-- accompanying such products. Nothing herein should be construed as
-- constituting an additional warranty.
--
-- The C&C Power Enterprise number is 18642.
-- The ASN.1 prefix to, and including the C&C Power Enterprise is:
-- 1.3.6.1.4.1.18642
--
-- MIB Version 1.0
-- *********************************************************************
-- Release History
-- Initial Release Date: August 9, 2004 (Version 1.0)
-- Author: Jeff Gear
-- Revision History
-- Date:
-- Revision:
-- *********************************************************************
CCPOWER-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215;
ccpower OBJECT IDENTIFIER ::= { enterprises 18642 }
dcSystem OBJECT IDENTIFIER ::= { ccpower 1 }
-- *********************************************************************
-- readWriteObjects definition
-- *********************************************************************
readWriteObjects OBJECT IDENTIFIER ::= { dcSystem 1 }
-- *********************************************************************
-- readWriteObjects.settings definition
-- *********************************************************************
settings OBJECT IDENTIFIER ::= { readWriteObjects 1 }
floatVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Rectifier DC Output Voltage.
Return value is XXX representing XX.X volts."
::= { settings 1 }
overloadCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Current which when exceeded will cause an alarm.
Return value is XXXX representing XXXX amps."
::= { settings 2 }
highVoltageAlarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Voltage which when exceeded will cause an alarm.
Return value is XXX representing XX.X volts."
::= { settings 3 }
lowVoltageAlarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Voltage which when exceeded will cause an alarm.
Return value is XXX representing XX.X volts."
::= { settings 4 }
disconnect1Voltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Voltage which when exceeded will cause a specific load to disconnect.
Return value is XXX representing XX.X volts."
::= { settings 5 }
disconnect1Temperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Temperature which when exceeded will cause a specific load to disconnect.
Return value is XX representing XX <20>C."
::= { settings 6 }
disconnect1LoadShedSundayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Sunday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 7 }
disconnect1LoadShedMondayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Monday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 8 }
disconnect1LoadShedTuesdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Tuesday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 9 }
disconnect1LoadShedWednesdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Wednesday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 10 }
disconnect1LoadShedThursdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Thursday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 11 }
disconnect1LoadShedFridayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Friday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 12 }
disconnect1LoadShedSaturdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Saturday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 13 }
disconnect2Voltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Voltage which when exceeded will cause a specific load to disconnect.
Return value is XXX representing XX.X volts."
::= { settings 14 }
disconnect2Temperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Temperature which when exceeded will cause a specific load to disconnect.
Return value is XX representing XX <20>C."
::= { settings 15 }
disconnect2LoadShedSundayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Sunday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 16 }
disconnect2LoadShedMondayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Monday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 17 }
disconnect2LoadShedTuesdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Tuesday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 18 }
disconnect2LoadShedWednesdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Wednesday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 19 }
disconnect2LoadShedThursdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Thursday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 20 }
disconnect2LoadShedFridayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Friday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 21 }
disconnect2LoadShedSaturdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Saturday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 22 }
disconnect3Voltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Voltage which when exceeded will cause a specific load to disconnect.
Return value is XXX representing XX.X volts."
::= { settings 23 }
disconnect3Temperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Temperature which when exceeded will cause a specific load to disconnect.
Return value is XX representing XX <20>C."
::= { settings 24 }
disconnect3LoadShedSundayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Sunday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 25 }
disconnect3LoadShedMondayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Monday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 26 }
disconnect3LoadShedTuesdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Tuesday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 27 }
disconnect3LoadShedWednesdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Wednesday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 28 }
disconnect3LoadShedThursdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Thursday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 29 }
disconnect3LoadShedFridayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Friday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 30 }
disconnect3LoadShedSaturdayOff OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Saturday which when reached will cause a specific load to disconnect.
Return value is XX:XX representing HH:MM."
::= { settings 31 }
reconnect1Voltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Voltage which when reached will cause a specific load to reconnect.
Return value is XXX representing XX.X volts."
::= { settings 32 }
reconnect1LoadShedSundayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 33 }
reconnect1LoadShedMondayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Monday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 34 }
reconnect1LoadShedTuesdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Tuesday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 35 }
reconnect1LoadShedWednesdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Wednesday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 36 }
reconnect1LoadShedThursdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Thursday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 37 }
reconnect1LoadShedFridayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Friday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 38 }
reconnect1LoadShedSaturdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Saturday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 39 }
reconnect2Voltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Voltage which when reached will cause a specific load to reconnect.
Return value is XXX representing XX.X volts."
::= { settings 40 }
reconnect2LoadShedSundayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Sunday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 41 }
reconnect2LoadShedMondayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Monday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 42 }
reconnect2LoadShedTuesdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Tuesday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 43 }
reconnect2LoadShedWednesdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Wednesday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 44 }
reconnect2LoadShedThursdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Thursday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 45 }
reconnect2LoadShedFridayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Friday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 46 }
reconnect2LoadShedSaturdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Saturday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 47 }
reconnect3Voltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Voltage which when reached will cause a specific load to reconnect.
Return value is XXX representing XX.X volts."
::= { settings 48 }
reconnect3LoadShedSundayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Sunday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 49 }
reconnect3LoadShedMondayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Monday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 50 }
reconnect3LoadShedTuesdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Tuesday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 51 }
reconnect3LoadShedWednesdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Wednesday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 52 }
reconnect3LoadShedThursdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Thursday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 53 }
reconnect3LoadShedFridayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Friday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 54 }
reconnect3LoadShedSaturdayOn OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Time on Saturday which when reached will cause a specific load to reconnect.
Return value is XX:XX representing HH:MM."
::= { settings 55 }
equalizeTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Number of hours the equalize voltage is to be applied.
Return value is XXX representing XX.X hours."
::= { settings 56 }
equalizeVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Equalize voltage to be applied.
Return value is XXX representing XX.X volts."
::= { settings 57 }
batteryResistancePercentChange OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Resistance percentange change that when reached will cause an alarm.
Return value is XXX representing XXX %."
::= { settings 58 }
batteryResistanceTestInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Battery resistance test interval.
Return value is XX representing XX weeks."
::= { settings 59 }
loadShedTimeControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Load shed time control enabled/disabled status.
Return value: 1 = time control enabled, 2 = time control disabled."
::= { settings 60 }
batteryFloatCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Battery float current.
Return value is XXX representing XXX amps."
::= { settings 61 }
-- *********************************************************************
-- readOnlyObjects definition
-- *********************************************************************
readOnlyObjects OBJECT IDENTIFIER ::= { dcSystem 2 }
-- *********************************************************************
-- readOnlyObjects.rectifiers definition
-- *********************************************************************
rectifiers OBJECT IDENTIFIER ::= { readOnlyObjects 1 }
rectifierFloatVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Rectifier float voltage.
Return value is XXX representing XX.X volts. Valid ranges are 24.0 to 57.0 volts."
::= { rectifiers 1 }
rectifierLoadCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Rectifier DC load current.
Return value is XXXX representing XXXX amps. Valid ranges are 0000 to 5000 amps."
::= { rectifiers 2}
-- *********************************************************************
-- readOnlyObjects.batteries definition
-- *********************************************************************
batteries OBJECT IDENTIFIER ::= { readOnlyObjects 2 }
batteryCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery current.
Return value is XXXX representing XXXX amps. Valid ranges are 0000 to 1000 amps."
::= { batteries 1 }
batteryTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery temperature.
Return value is XX representing XX <20>C. Valid ranges are -40 to 99 <20>C."
::= { batteries 2 }
batteryResistanceReference OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Initial battery resistance.
Return value is XXXXX representing X.XXXX ohms. Valid ranges are 0.0000 to 5.0000 ohms."
::= { batteries 3 }
batteryResistanceReading OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Last battery resistance reading.
Return value is XXXXX representing X.XXXX ohms. Valid ranges are 0.0000 to 5.0000 ohms."
::= { batteries 4 }
batteryResistanceChange OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Percent change from last battery resistance reading.
Return value is XXX representing XXX %. Valid ranges are 001 to 999 %."
::= { batteries 5 }
batteryCycles1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Number of discharge/recharge cycles less than 1 minute.
Return value is XXX representing XXX cycles. Valid ranges are 000 to 255 cycles."
::= { batteries 6 }
batteryCycles1to5 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Number of discharge/recharge cycles from 1 to 5 minutes.
Return value is XXX representing XXX cycles. Valid ranges are 000 to 255 cycles."
::= { batteries 7 }
batteryCycles5to15 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Number of discharge/recharge cycles from 5 to 15 minutes.
Return value is XXX representing XXX cycles. Valid ranges are 000 to 255 cycles."
::= { batteries 8 }
batteryCycles15 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Number of discharge/recharge cycles greater than 15 minutes.
Return value is XXX representing XXX cycles. Valid ranges are 000 to 255 cycles."
::= { batteries 9 }
batteryCycles15LastCycleDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Last cycle date of batteryCycles15.
Return value is MM-DD-YY, HH-MM."
::= { batteries 10 }
batteryCycles15LastDuration OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Duration of batteryCycles15 last cycle.
Return value is XXXX representing XXXX minutes."
::= { batteries 11 }
batteryTestFault OBJECT-TYPE
SYNTAX INTEGER {
abort1(1),
abort2(2),
abort3(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery failure has occured during battery restistance test.
Return value: 1 = Abort 1, 2 = Abort 2, 3 = Abort 3, 4 = None."
::= { batteries 12 }
-- *********************************************************************
-- readOnlyObjects.factorySettings definition
-- *********************************************************************
factorySettings OBJECT IDENTIFIER ::= { readOnlyObjects 3 }
floatVoltagePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Float voltage factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 1 }
highVoltageAlarmPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "High voltage alarm factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 2 }
lowVoltageAlarmPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low voltage alarm factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 3 }
disconnect1VoltagePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect voltage 1 factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 4 }
disconnect1TemperaturePreset OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect temperature 1 factory setting.
Return value is XX <20>C."
::= { factorySettings 5 }
disconnect1LoadShedSundayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 1 load shed Sunday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 6 }
disconnect1LoadShedMondayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 1 load shed Monday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 7 }
disconnect1LoadShedTuesdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 1 load shed Tuesday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 8 }
disconnect1LoadShedWednesdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 1 load shed Wednesday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 9 }
disconnect1LoadShedThursdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 1 load shed Thursday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 10 }
disconnect1LoadShedFridayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 1 load shed Friday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 11 }
disconnect1LoadShedSaturdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 1 load shed Saturday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 12 }
reconnectVoltage1Presets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Reconnect voltage 1 factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 13 }
disconnect2VoltagePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect voltage 2 factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 14 }
disconnect2TemperaturePreset OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect temperature 2 factory setting.
Return value is XX <20>C."
::= { factorySettings 15 }
disconnect2LoadShedSundayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 2 load shed Sunday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 16 }
disconnect2LoadShedMondayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 2 load shed Monday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 17 }
disconnect2LoadShedTuesdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 2 load shed Tuesday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 18 }
disconnect2LoadShedWednesdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 2 load shed Wednesday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 19 }
disconnect2LoadShedThursdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 2 load shed Thursday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 20 }
disconnect2LoadShedFridayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 2 load shed Friday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 21 }
disconnect2LoadShedSaturdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 2 load shed Saturday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 22 }
reconnect2VoltagePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Reconnect voltage 2 factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 23 }
disconnect3VoltagePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect voltage 3 factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 24 }
disconnect3TemperaturePreset OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect temperature 3 factory setting.
Return value is XX <20>C."
::= { factorySettings 25 }
disconnect3LoadShedSundayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 3 load shed Sunday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 26 }
disconnect3LoadShedMondayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 3 load shed Monday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 27 }
disconnect3LoadShedTuesdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 3 load shed Tuesday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 28 }
disconnect3LoadShedWednesdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 3 load shed Wednesday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 29 }
disconnect3LoadShedThursdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 3 load shed Thursday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 30 }
disconnect3LoadShedFridayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 3 load shed Friday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 31 }
disconnect3LoadShedSaturdayPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Disconnect 3 load shed Saturday time settings.
Return value is XX:Xx off, XX:XX on."
::= { factorySettings 32 }
reconnect3VoltagePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Reconnect voltage 3 factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 33 }
overloadCurrentPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Overload current factory setting range.
Return value is XXXX amps min, XXXX amps max."
::= { factorySettings 34 }
maximumCurrentPreset OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum current factory setting.
Return value is XXXX amps."
::= { factorySettings 35 }
batteryFloatCurrentPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery float current factory settings.
Return value is XXX amps min, XXX amps max."
::= { factorySettings 36 }
equalizeTimePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Equalize time factory setting range.
Return value is 00.0 hours min, XX.X hours max."
::= { factorySettings 37 }
equalizeVoltagePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Equalize voltage factory setting range.
Return value is XX.X volts min, XX.X volts max."
::= { factorySettings 38 }
batteryResistancePresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery resistance percent change factory setting range.
Return value is XXX % min, XXX % max."
::= { factorySettings 39 }
batteryTestIntervalPresets OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery resistance test interval factory setting range.
Return value is XX weeks min, XX weeks max."
::= { factorySettings 40 }
-- *********************************************************************
-- readOnlyObjects.alarmStatus definition
-- *********************************************************************
alarmStatus OBJECT IDENTIFIER ::= { readOnlyObjects 4 }
highVoltageAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "High voltage alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 1 }
lowVoltageAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low voltage alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 2 }
overloadAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Overload alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 3 }
breakerAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Breaker alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 4 }
acFailureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "AC failure alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 5 }
fanFailureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Fan failure alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 6 }
rectifierFailureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Rectifier failure alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 7 }
majorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Major alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 8 }
lowVoltageDisconnect1TemperatureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low voltage disconnect 1 high temperature alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 9 }
lowVoltageDisconnect2TemperatureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low voltage disconnect 2 high temperature alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 10 }
lowVoltageDisconnect3TemperatureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low voltage disconnect 3 high temperature alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 11 }
lowVoltageDisconnect1VoltageAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low voltage disconnect 1 low voltage alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 12 }
lowVoltageDisconnect2VoltageAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low voltage disconnect 2 low voltage alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 13 }
lowVoltageDisconnect3VoltageAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low voltage disconnect 3 low voltage alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 14 }
batteryResistanceAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery resistance alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 15 }
batteryCurrentAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery resistance alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 16 }
batteryTestAbortCondition1AlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery test abort condition 1 alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 17 }
batteryTestAbortCondition2AlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery test abort condition 2 alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 18 }
batteryTestAbortCondition3AlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery test abort condition 3 alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 19 }
batteryDisconnectAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Battery disconnect alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 20 }
fuseAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Fuse alarm status.
Return value 1 = alarm inactive, 2 = alarm active."
::= { alarmStatus 21 }
-- *********************************************************************
-- readOnlyObjects.digitalSensorAlarms definition
-- *********************************************************************
digitalSensorAlarms OBJECT IDENTIFIER ::= { readOnlyObjects 5 }
breakerTrap TRAP-TYPE
ENTERPRISE ccpower
--#SEVERITY CRITICAL
DESCRIPTION "Breaker has tripped."
::= 0
fuseTrap TRAP-TYPE
ENTERPRISE ccpower
--#SEVERITY CRITICAL
DESCRIPTION "Fuse has opened."
::= 1
batteryDisconnectTrap TRAP-TYPE
ENTERPRISE ccpower
--#SEVERITY CRITICAL
DESCRIPTION "Battery disconnect has operated."
::= 2
programmableTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Programmable alarm has occurred."
--#SEVERITY CRITICAL
::= 3
-- *********************************************************************
-- readOnlyObjects.SystemAlarms definition
-- *********************************************************************
systemAlarms OBJECT IDENTIFIER ::= { readOnlyObjects 6 }
highVoltageTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Float voltage has exceeded preset value.
Return value: High voltage alarm XX.X volts."
--#SEVERITY WARNING
::= 4
lowVoltageTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Float voltage is below preset value.
Return value: Low voltage alarm XX.X volts."
--#SEVERITY WARNING
::= 5
loadOverCurrentTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load current has exceeded preset value.
Return value: Load over current alarm XXXX amps."
--#SEVERITY WARNING
::= 6
batteryFloatCurrentTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery float current has exceeded preset value.
Return value: Battery float current alarm XXXX amps."
--#SEVERITY CRITICAL
::= 7
loadDisconnect1VoltageTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 1 voltage has dropped below preset value.
Return value: Load disconnect 1 voltage XX.X volts."
--#SEVERITY CRITICAL
::= 8
loadDisconnect2VoltageTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 2 voltage has dropped below preset value.
Return value: Load disconnect 2 voltage XX.X volts."
--#SEVERITY CRITICAL
::= 9
loadDisconnect3VoltageTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 3 voltage has dropped below preset value.
Return value: Load disconnect 3 voltage XX.X volts."
--#SEVERITY CRITICAL
::= 10
loadDisconnect1TemperatureTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 1 temperature has exceeded preset value.
Return value: Load disconnect 1 temperature alarm XX <20>C."
--#SEVERITY CRITICAL
::= 11
loadDisconnect2TemperatureTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 2 temperature has exceeded preset value.
Return value: Load disconnect 2 temperature alarm XX <20>C."
--#SEVERITY CRITICAL
::= 12
loadDisconnect3TemperatureTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 3 temperature has exceeded preset value.
Return value: Load disconnect 3 temperature alarm XX <20>C."
--#SEVERITY CRITICAL
::= 13
rectifierFailureTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Rectifier failure.
Return value: Rectifier failure."
--#SEVERITY WARNING
::= 14
fanFailureTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Rectifier fan has failed.
Return value: Fan failure."
--#SEVERITY CRITICAL
::= 15
acFailureTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Rectifier has lost AC input power.
Return value: AC failure."
--#SEVERITY CRITICAL
::= 16
majorFailureTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Multiple failures of AC, rectififers, fans or a programmed alarm.
Return value: Multiple AC, fan, rectifier or optional alarm failures has occurred."
--#SEVERITY CRITICAL
::= 17
batteryResistanceTrap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery resistance has increased by a programmed percentage.
Return value: Battery resistance alarm X.XXXX ohms, XXX %."
--#SEVERITY WARNING
::= 18
batteryTestAbort1Trap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery failure abort 1 has occured during battery resistance test.
Return value: Battery test failure: Abort 1."
--#SEVERITY CRITICAL
::= 19
batteryTestAbort2Trap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery failure abort 2 has occured during battery resistance test.
Return value: Battery test failure: Abort 2."
--#SEVERITY CRITICAL
::= 20
batteryTestAbort3Trap TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery failure abort 3 has occured during battery resistance test.
Return value: Battery test failure: Abort 3."
--#SEVERITY CRITICAL
::= 21
-- *********************************************************************
-- readOnlyObjects.digitalSensorAlarmClears definition
-- *********************************************************************
digitalSensorAlarmClears OBJECT IDENTIFIER ::= { readOnlyObjects 7 }
breakerTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Breaker alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 100
fuseTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Fuse alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 101
batteryDisconnectTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery disconnect alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 102
programmableTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Programmable alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 103
-- *********************************************************************
-- readOnlyObjects.SystemAlarmClears definition
-- *********************************************************************
systemAlarmClears OBJECT IDENTIFIER ::= { readOnlyObjects 8 }
highVoltageTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "High voltage alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 104
lowVoltageTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Low voltage alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 105
loadOverCurrentTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load over current alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 106
batteryFloatCurrentTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery float current alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 107
loadDisconnect1VoltageTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 1 voltage alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 108
loadDisconnect2VoltageTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 2 voltage alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 109
loadDisconnect3VoltageTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 3 voltage alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 110
loadDisconnect1TemperatureTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 1 temperature alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 111
loadDisconnect2TemperatureTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 2 temperature alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 112
loadDisconnect3TemperatureTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Load disconnect 3 temperature alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 113
rectifierFailureTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Rectififer failure alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 114
fanFailureTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Fan failure alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 115
acFailureTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "AC failure alarm been cleared."
--#SEVERITY INFORMATIONAL
::= 116
majorFailureTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Major failure alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 117
batteryResistanceTrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery resistance alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 118
batteryTestAbort1TrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery test abort 1 alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 119
batteryTestAbort2TrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery test abort 2 alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 120
batteryTestAbort3TrapClear TRAP-TYPE
ENTERPRISE ccpower
DESCRIPTION "Battery test abort 3 alarm has been cleared."
--#SEVERITY INFORMATIONAL
::= 121
END