DKT-CATV-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
IMPORTS
 | 
			
		||||
    MODULE-IDENTITY, OBJECT-TYPE, Integer32,
 | 
			
		||||
    Counter32                   FROM SNMPv2-SMI
 | 
			
		||||
    OBJECT-GROUP				FROM SNMPv2-CONF
 | 
			
		||||
    dkt                         FROM DKT-MIB;
 | 
			
		||||
 | 
			
		||||
catvMIB MODULE-IDENTITY
 | 
			
		||||
    LAST-UPDATED  "200812170000Z"
 | 
			
		||||
    ORGANIZATION "DKT A/S"
 | 
			
		||||
    CONTACT-INFO
 | 
			
		||||
        "postal:  DKT A/S
 | 
			
		||||
                  Fanoevej 6
 | 
			
		||||
                  DK-4060 Kirke Saaby
 | 
			
		||||
                  Denmark
 | 
			
		||||
 | 
			
		||||
         email:   info@dktcomega.com"
 | 
			
		||||
    DESCRIPTION   "DKT CATV MIB."
 | 
			
		||||
    ::= { dkt 11 }
 | 
			
		||||
 | 
			
		||||
catvVersion OBJECT-TYPE
 | 
			
		||||
    SYNTAX	OCTET STRING (SIZE(0..100))
 | 
			
		||||
    MAX-ACCESS	read-only
 | 
			
		||||
    STATUS	current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
	"Version string for the CATV module"
 | 
			
		||||
    ::= { catvMIB 1 }
 | 
			
		||||
 | 
			
		||||
catvSwitch OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER
 | 
			
		||||
    MAX-ACCESS  read-write
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Switch CATV module on or off. 1 = on 0 = off"
 | 
			
		||||
    ::= { catvMIB 2 }
 | 
			
		||||
 | 
			
		||||
catvSignalDetect OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "CATV Rx signal detect. 1 = signal, 0 = no signal"
 | 
			
		||||
    ::= { catvMIB 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
catvModuleGroup OBJECT-GROUP
 | 
			
		||||
    OBJECTS {
 | 
			
		||||
		catvVersion,
 | 
			
		||||
		catvSwitch,
 | 
			
		||||
		catvSignalDetect
 | 
			
		||||
    }
 | 
			
		||||
    STATUS current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "The objects are related to the DKT CATV module."
 | 
			
		||||
    ::= { catvMIB 4 }
 | 
			
		||||
 | 
			
		||||
END
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
							
								
								
									
										1415
									
								
								MIBS/dkt/DKT-FE-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										1415
									
								
								MIBS/dkt/DKT-FE-MIB
									
									
									
									
									
										Normal file
									
								
							
										
											
												File diff suppressed because it is too large
												Load Diff
											
										
									
								
							
							
								
								
									
										1239
									
								
								MIBS/dkt/DKT-GE-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										1239
									
								
								MIBS/dkt/DKT-GE-MIB
									
									
									
									
									
										Normal file
									
								
							
										
											
												File diff suppressed because it is too large
												Load Diff
											
										
									
								
							
							
								
								
									
										61
									
								
								MIBS/dkt/DKT-GENERIC-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										61
									
								
								MIBS/dkt/DKT-GENERIC-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,61 @@
 | 
			
		||||
DKT-GENERIC-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
IMPORTS
 | 
			
		||||
    MODULE-IDENTITY, OBJECT-TYPE, Integer32,
 | 
			
		||||
    Counter32                   FROM SNMPv2-SMI
 | 
			
		||||
    OBJECT-GROUP				FROM SNMPv2-CONF
 | 
			
		||||
    dkt                         FROM DKT-MIB;
 | 
			
		||||
 | 
			
		||||
genericMIB MODULE-IDENTITY
 | 
			
		||||
    LAST-UPDATED  "200812170000Z"
 | 
			
		||||
    ORGANIZATION "DKT A/S"
 | 
			
		||||
    CONTACT-INFO
 | 
			
		||||
        "postal:  DKT A/S
 | 
			
		||||
                  Fanoevej 6
 | 
			
		||||
                  DK-4060 Kirke Saaby
 | 
			
		||||
                  Denmark
 | 
			
		||||
 | 
			
		||||
         email:   info@dktcomega.com"
 | 
			
		||||
    DESCRIPTION   "DKT GENERIC MIB."
 | 
			
		||||
    ::= { dkt 10 }
 | 
			
		||||
 | 
			
		||||
hwVersion OBJECT-TYPE
 | 
			
		||||
    SYNTAX	OCTET STRING (SIZE(0..100))
 | 
			
		||||
    MAX-ACCESS	read-only
 | 
			
		||||
    STATUS	current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
	"Version string for the HW"
 | 
			
		||||
    ::= { genericMIB 1 }
 | 
			
		||||
 | 
			
		||||
swVersion OBJECT-TYPE
 | 
			
		||||
    SYNTAX	OCTET STRING (SIZE(0..100))
 | 
			
		||||
    MAX-ACCESS	read-only
 | 
			
		||||
    STATUS	current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
	"Version string for the SW"
 | 
			
		||||
    ::= { genericMIB 2 }
 | 
			
		||||
 | 
			
		||||
reboot OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER
 | 
			
		||||
    MAX-ACCESS  write-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Set to 1 to reboot the device"
 | 
			
		||||
    ::= { genericMIB 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
genericModuleGroup OBJECT-GROUP
 | 
			
		||||
    OBJECTS {
 | 
			
		||||
		hwVersion,
 | 
			
		||||
		swVersion,
 | 
			
		||||
		reboot
 | 
			
		||||
    }
 | 
			
		||||
    STATUS current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "The objects are related to all DKT modules."
 | 
			
		||||
    ::= { genericMIB 4 }
 | 
			
		||||
 | 
			
		||||
END
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
							
								
								
									
										18
									
								
								MIBS/dkt/DKT-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										18
									
								
								MIBS/dkt/DKT-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,18 @@
 | 
			
		||||
DKT-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
IMPORTS
 | 
			
		||||
    MODULE-IDENTITY, enterprises                FROM SNMPv2-SMI;
 | 
			
		||||
 | 
			
		||||
dkt MODULE-IDENTITY
 | 
			
		||||
    LAST-UPDATED  "200802240000Z"
 | 
			
		||||
    ORGANIZATION  "DKT A/S"
 | 
			
		||||
    CONTACT-INFO
 | 
			
		||||
        "postal: DKT A/S
 | 
			
		||||
                 Fanoevej 6
 | 
			
		||||
                 DK-4060 Kirke Saaby
 | 
			
		||||
                 Denmark
 | 
			
		||||
 | 
			
		||||
         email:  info@dkt.dk"
 | 
			
		||||
    DESCRIPTION   "Base MIB for DKT."
 | 
			
		||||
    ::= { enterprises 27304 }
 | 
			
		||||
END
 | 
			
		||||
							
								
								
									
										1642
									
								
								MIBS/dkt/DKT-RMON-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										1642
									
								
								MIBS/dkt/DKT-RMON-MIB
									
									
									
									
									
										Normal file
									
								
							
										
											
												File diff suppressed because it is too large
												Load Diff
											
										
									
								
							
							
								
								
									
										377
									
								
								MIBS/dkt/IDKT-F2-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										377
									
								
								MIBS/dkt/IDKT-F2-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,377 @@
 | 
			
		||||
IDKT-F2-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
IMPORTS
 | 
			
		||||
    MODULE-IDENTITY, OBJECT-TYPE, Integer32,
 | 
			
		||||
    Counter32                   FROM SNMPv2-SMI
 | 
			
		||||
    OBJECT-GROUP                FROM SNMPv2-CONF
 | 
			
		||||
    dkt                         FROM DKT-MIB
 | 
			
		||||
    MacAddress                  FROM SNMPv2-TC;
 | 
			
		||||
 | 
			
		||||
f2MIB MODULE-IDENTITY
 | 
			
		||||
    LAST-UPDATED  "201504210000Z"
 | 
			
		||||
    ORGANIZATION "DKT A/S"
 | 
			
		||||
    CONTACT-INFO
 | 
			
		||||
        "postal:  DKT A/S
 | 
			
		||||
                  Fanoevej 6
 | 
			
		||||
                  DK-4060 Kirke Saaby
 | 
			
		||||
                  Denmark
 | 
			
		||||
 | 
			
		||||
         email:   info@dktcomega.com"
 | 
			
		||||
    DESCRIPTION   "DKT 797xx series MIB."
 | 
			
		||||
    ::= { dkt 15 }
 | 
			
		||||
 | 
			
		||||
f2SwitchEngine OBJECT IDENTIFIER ::= { f2MIB 1 }
 | 
			
		||||
 | 
			
		||||
f2IGMPSnooping OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-write
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Starts/stops IGMP snooping, input parameter 0 = stops IGMP snooping, 1 = starts IGMP snooping. Per Default IGMP snooping is disabled."
 | 
			
		||||
    ::= { f2SwitchEngine 1 }
 | 
			
		||||
 | 
			
		||||
f2MTU OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..8960)
 | 
			
		||||
    MAX-ACCESS  read-write
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Set and get MTU. The following values are valid: 3072, 4096, 6144, 8960 (3k, 4k, 6k and 8960 bytes)"
 | 
			
		||||
    ::= { f2SwitchEngine 2 }
 | 
			
		||||
 | 
			
		||||
f2FWDTable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SEQUENCE OF F2FWDMacAddressEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Get learned MAC addresses from LAN side of switch engine"
 | 
			
		||||
    ::= { f2SwitchEngine 3 }
 | 
			
		||||
 | 
			
		||||
f2FWDMacAddressEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX      F2FWDMacAddressEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Learned MAC address from LAN side of switch engine"
 | 
			
		||||
    ::= { f2FWDTable 1 }
 | 
			
		||||
 | 
			
		||||
F2FWDMacAddressEntry ::= SEQUENCE {
 | 
			
		||||
    F2FWDMacAddress OCTET STRING
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
F2FWDMacAddress OBJECT-TYPE
 | 
			
		||||
    SYNTAX      MacAddress
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "MAC address from LAN"
 | 
			
		||||
    ::= { f2FWDMacAddressEntry 1 }
 | 
			
		||||
 | 
			
		||||
f2Ports OBJECT IDENTIFIER ::= { f2MIB 2 }
 | 
			
		||||
 | 
			
		||||
f2CPUPort OBJECT IDENTIFIER ::= { f2Ports 1 }
 | 
			
		||||
 | 
			
		||||
f2CPUPortAutoNegotiation OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..10)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays auto negotiation state for the port."
 | 
			
		||||
    ::= { f2CPUPort 1 }
 | 
			
		||||
 | 
			
		||||
f2CPUPortSpeedMode OBJECT-TYPE
 | 
			
		||||
    SYNTAX      OCTET STRING (SIZE(0..10))
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays the speed and duplex mode on the port."
 | 
			
		||||
    ::= { f2CPUPort 2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2CPUPortLinkStatus OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays the Link status for the port"
 | 
			
		||||
    ::= { f2CPUPort 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2CPUPortFlowControl OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
 | 
			
		||||
    ::= { f2CPUPort 4 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2CPUPortEnable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Status for CPU port. Always 1 for enabled."
 | 
			
		||||
    ::= { f2CPUPort 5 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2WANPort OBJECT IDENTIFIER ::= { f2Ports 2 }
 | 
			
		||||
 | 
			
		||||
f2WANPortAutoNegotiation OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..10)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays auto negotiation state for the port."
 | 
			
		||||
    ::= { f2WANPort 1 }
 | 
			
		||||
 | 
			
		||||
f2WANPortSpeedMode OBJECT-TYPE
 | 
			
		||||
    SYNTAX      OCTET STRING (SIZE(0..10))
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
 | 
			
		||||
    ::= { f2WANPort 2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2WANPortLinkStatus OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays the Link status for the port"
 | 
			
		||||
    ::= { f2WANPort 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2WANPortFlowControl OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
 | 
			
		||||
    ::= { f2WANPort 4 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2WANPortEnable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Status for WAN port. Always 1 for enabled."
 | 
			
		||||
    ::= { f2WANPort 5 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN1Port OBJECT IDENTIFIER ::= { f2Ports 3 }
 | 
			
		||||
 | 
			
		||||
f2LAN1PortAutoNegotiation OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays auto negotiation state for the port."
 | 
			
		||||
    ::= { f2LAN1Port 1 }
 | 
			
		||||
 | 
			
		||||
f2LAN1PortSpeedMode OBJECT-TYPE
 | 
			
		||||
    SYNTAX      OCTET STRING (SIZE(0..10))
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
 | 
			
		||||
    ::= { f2LAN1Port 2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN1PortLinkStatus OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays the Link status for the port"
 | 
			
		||||
    ::= { f2LAN1Port 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN1PortFlowControl OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
 | 
			
		||||
    ::= { f2LAN1Port 4 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN1PortEnable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-write
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Enables/Disables LAN1 port. Set to 1 for Enabled set to 0 for Disabled."
 | 
			
		||||
    ::= { f2LAN1Port 5 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN2Port OBJECT IDENTIFIER ::= { f2Ports 4 }
 | 
			
		||||
 | 
			
		||||
f2LAN2PortAutoNegotiation OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays auto negotiation state for the port."
 | 
			
		||||
    ::= { f2LAN2Port 1 }
 | 
			
		||||
 | 
			
		||||
f2LAN2PortSpeedMode OBJECT-TYPE
 | 
			
		||||
    SYNTAX      OCTET STRING (SIZE(0..10))
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
 | 
			
		||||
    ::= { f2LAN2Port 2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN2PortLinkStatus OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays the Link status for the port"
 | 
			
		||||
    ::= { f2LAN2Port 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN2PortFlowControl OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
 | 
			
		||||
    ::= { f2LAN2Port 4 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN2PortEnable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-write
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Enables/Disables LAN2 port. Set to 1 for Enabled set to 0 for Disabled."
 | 
			
		||||
    ::= { f2LAN2Port 5 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN3Port OBJECT IDENTIFIER ::= { f2Ports 5 }
 | 
			
		||||
 | 
			
		||||
f2LAN3PortAutoNegotiation OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays auto negotiation state for the port."
 | 
			
		||||
    ::= { f2LAN3Port 1 }
 | 
			
		||||
 | 
			
		||||
f2LAN3PortSpeedMode OBJECT-TYPE
 | 
			
		||||
    SYNTAX      OCTET STRING (SIZE(0..10))
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
 | 
			
		||||
    ::= { f2LAN3Port 2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN3PortLinkStatus OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays the Link status for the port"
 | 
			
		||||
    ::= { f2LAN3Port 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN3PortFlowControl OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
 | 
			
		||||
    ::= { f2LAN3Port 4 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN3PortEnable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-write
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Enables/Disables LAN3 port. Set to 1 for Enabled set to 0 for Disabled."
 | 
			
		||||
    ::= { f2LAN3Port 5 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN4Port OBJECT IDENTIFIER ::= { f2Ports 6 }
 | 
			
		||||
 | 
			
		||||
f2LAN4PortAutoNegotiation OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays auto negotiation state for the port."
 | 
			
		||||
    ::= { f2LAN4Port 1 }
 | 
			
		||||
 | 
			
		||||
f2LAN4PortSpeedMode OBJECT-TYPE
 | 
			
		||||
    SYNTAX      OCTET STRING (SIZE(0..10))
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION  
 | 
			
		||||
        "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
 | 
			
		||||
    ::= { f2LAN4Port 2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN4PortLinkStatus OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays the Link status for the port"
 | 
			
		||||
    ::= { f2LAN4Port 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN4PortFlowControl OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
 | 
			
		||||
    ::= { f2LAN4Port 4 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2LAN4PortEnable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      INTEGER (0..1)
 | 
			
		||||
    MAX-ACCESS  read-write
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "Enables/Disables LAN4 port. Set to 1 for Enabled set to 0 for Disabled."
 | 
			
		||||
    ::= { f2LAN4Port 5 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
f2ModuleGroup OBJECT-GROUP
 | 
			
		||||
        OBJECTS {
 | 
			
		||||
                f2SwitchEngine,
 | 
			
		||||
                f2IGMPSnooping,
 | 
			
		||||
                f2MTU,
 | 
			
		||||
                f2Ports,
 | 
			
		||||
                f2CPUPort,
 | 
			
		||||
                f2CPUPortAutoNegotiation, f2CPUPortSpeedMode, f2CPUPortLinkStatus, f2CPUPortFlowControl, f2CPUPortEnable, 
 | 
			
		||||
                f2WANPort,
 | 
			
		||||
                f2WANPortAutoNegotiation, f2WANPortSpeedMode, f2WANPortLinkStatus, f2WANPortFlowControl, f2WANPortEnable, 
 | 
			
		||||
                f2LAN1Port,
 | 
			
		||||
                f2LAN1PortAutoNegotiation, f2LAN1PortSpeedMode, f2LAN1PortLinkStatus, f2LAN1PortFlowControl, f2LAN1PortEnable, 
 | 
			
		||||
                f2LAN2Port,
 | 
			
		||||
                f2LAN2PortAutoNegotiation, f2LAN2PortSpeedMode, f2LAN2PortLinkStatus, f2LAN2PortFlowControl, f2LAN2PortEnable, 
 | 
			
		||||
                f2LAN3Port,
 | 
			
		||||
                f2LAN3PortAutoNegotiation, f2LAN3PortSpeedMode, f2LAN3PortLinkStatus, f2LAN3PortFlowControl, f2LAN3PortEnable, 
 | 
			
		||||
                f2LAN4Port,
 | 
			
		||||
                f2LAN4PortAutoNegotiation, f2LAN4PortSpeedMode, f2LAN4PortLinkStatus, f2LAN4PortFlowControl, f2LAN4PortEnable
 | 
			
		||||
        }
 | 
			
		||||
    STATUS current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "The objects are related to the DKT 797xx series module, MIB rev 09."
 | 
			
		||||
    ::= { f2MIB 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
END
 | 
			
		||||
		Reference in New Issue
	
	Block a user