1611 lines
		
	
	
		
			59 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			1611 lines
		
	
	
		
			59 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
-- =================================================================
 | 
						|
-- Copyright (c) 2004-2019 New H3C Tech. Co., Ltd.  All rights reserved.
 | 
						|
--
 | 
						|
-- Description: Power over ethernet extend MIB
 | 
						|
-- Reference: POWER-ETHERNET-MIB
 | 
						|
-- Version: V1.7
 | 
						|
-- History:
 | 
						|
--   V1.0 2004-07-24 Created by Gaolong
 | 
						|
--   V1.1 2004-09-08 Update file by Gaolong for some syntax errors.
 | 
						|
--   V1.2 2004-11-19 Update file by liuhongxu for poe need.
 | 
						|
--                   add hh3cMainPsePriorityMode¡¢hh3cPsePowerMaxValue¡¢
 | 
						|
--                   hh3cpsePDChangNotification adjust the objects' sequence of
 | 
						|
--                   hh3cPsePortTable and hh3cMainPseTable add the description
 | 
						|
--                   of MANDATORY-GROUPS in hh3cPseCompliance.
 | 
						|
--   V1.3 2004-12-16 Update file by liuhongxu for poe profile
 | 
						|
--                   add hh3cPsePortProfile, hh3cPseProfilesTable
 | 
						|
--                   change the name of hh3cPseProfileIndex add
 | 
						|
--                   hh3cPseProfileApplyNum.  adjust the format of this mib.
 | 
						|
--   V1.4 2005-03-29 Update file by Wangzhaoyan for poe pow need.
 | 
						|
--                   add hh3cPOEPowerObjects, hh3cPOEThresholdLimitObjs,
 | 
						|
--                   hh3cPOESupModuleInfoObjs, hh3cPOEDCOutStateObjects,
 | 
						|
--                   hh3cPOEDCDCOutInfoObjects, hh3cPOEACSwitchStateModuleObjs,
 | 
						|
--                   hh3cPOEInCurStateObjects, hh3cPOEAlarmStateObjects and the
 | 
						|
--                   sub-nodes.  add 17 traps change the node name from
 | 
						|
--                   hh3cpsePDChangNotification to hh3cpsePDChangeNotification
 | 
						|
--                   change some detail as the suggestion from Wangyingxia and
 | 
						|
--                   Yangyang.  adjust the format of this mib.
 | 
						|
--   V1.5 2005-11-21 Update file by Liweizhen for controling the power-management
 | 
						|
--                   policy of PSE or PD.  Add hh3cPsePolicyMode, hh3cPDPolicyMode,
 | 
						|
--                   hh3cMainPsePowerPriority.
 | 
						|
--                   Delete some description of hh3cPsePortProfileIndex node.
 | 
						|
--                   Change the description of hh3cPseProfilePowerMode node.
 | 
						|
--                   Change SYNTAX OCTET STRING range for the following nodes:
 | 
						|
--                   hh3cPOEPowerType, hh3cPOESupervisionModuleName,
 | 
						|
--                   hh3cPOESMFactorName, hh3cPOEModuleHardVerInfo.
 | 
						|
--                   Adjust the format of this mib.
 | 
						|
--   V1.6 2015-07-21 Update file by Fangliwen for profile power limit.
 | 
						|
--                   Change the syntax of hh3cPseProfilePowerLimit node.
 | 
						|
--   V1.7 2019-5-23  Update file for PoE-AI. Add the following nodes:
 | 
						|
--                   hh3cPsePDDisableNotification,hh3cPsePortGroupIndex,
 | 
						|
--                   hh3cPsePortIndex and hh3cPsePortDisableInfo.
 | 
						|
-- =================================================================
 | 
						|
HH3C-POWER-ETH-EXT-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
      hh3cCommon
 | 
						|
              FROM HH3C-OID-MIB
 | 
						|
      pethPsePortGroupIndex, pethPsePortIndex,
 | 
						|
      pethMainPseGroupIndex, pethPsePortDetectionStatus
 | 
						|
              FROM POWER-ETHERNET-MIB
 | 
						|
      OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
 | 
						|
              FROM SNMPv2-CONF
 | 
						|
      Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
 | 
						|
              FROM SNMPv2-SMI
 | 
						|
      DisplayString, RowStatus, TEXTUAL-CONVENTION
 | 
						|
              FROM SNMPv2-TC;
 | 
						|
 | 
						|
 | 
						|
hh3cPowerEthernetExt MODULE-IDENTITY
 | 
						|
      LAST-UPDATED "201905230000Z"      -- May 23, 2019 at 00:00 GMT
 | 
						|
 | 
						|
      ORGANIZATION
 | 
						|
          "New H3C Tech. Co., Ltd."
 | 
						|
      CONTACT-INFO
 | 
						|
          "Platform Team New H3C Tech. Co., Ltd.
 | 
						|
          Hai-Dian District Beijing P.R. China
 | 
						|
          http://www.h3c.com
 | 
						|
          Zip:100085
 | 
						|
          "
 | 
						|
      DESCRIPTION
 | 
						|
              "Description."
 | 
						|
      REVISION "201905230000Z"
 | 
						|
      DESCRIPTION
 | 
						|
          "Add the following nodes:
 | 
						|
          hh3cPsePDDisableNotification,hh3cPsePortGroupIndex,
 | 
						|
          hh3cPsePortIndex and hh3cPsePortDisableInfo."
 | 
						|
      REVISION      "201507250000Z"
 | 
						|
      DESCRIPTION
 | 
						|
          "The initial version of this MIB module."
 | 
						|
          ::= { hh3cCommon 14 }
 | 
						|
 | 
						|
 | 
						|
--
 | 
						|
-- Node definitions
 | 
						|
--
 | 
						|
 | 
						|
hh3cPsePortTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cPsePortEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The indexing scheme is taken form that used by
 | 
						|
             the IETF Power MIB.  The same indexing scheme is
 | 
						|
             used to give continuity in behaviour between
 | 
						|
             that standard and this extensions definitioin."
 | 
						|
      ::= { hh3cPowerEthernetExt 1 }
 | 
						|
 | 
						|
 | 
						|
hh3cPsePortEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPsePortEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The pethPsePortGroupIndex is imported from the IETF Power MIB
 | 
						|
             and uniquely identifies the group containing the port to which
 | 
						|
             power ethernet PSE is connected.  Group means (box in the stack,
 | 
						|
             module in a rack).
 | 
						|
 | 
						|
             The pethPsePortPowerIndex is imported from the IETF Power MIB
 | 
						|
             and uniquely identifies the power ethernet PSE port within group
 | 
						|
             pethPseGroupIndex to which the power Ethernet PSE entry is
 | 
						|
             connected.  This value will match the local port number on a
 | 
						|
             switch."
 | 
						|
      INDEX { pethPsePortGroupIndex, pethPsePortIndex }
 | 
						|
      ::= { hh3cPsePortTable 1 }
 | 
						|
 | 
						|
 | 
						|
Hh3cPsePortEntry ::=
 | 
						|
      SEQUENCE {
 | 
						|
              hh3cPsePortFaultDescription
 | 
						|
                      DisplayString,
 | 
						|
              hh3cPsePortPeakPower
 | 
						|
                      Integer32,
 | 
						|
              hh3cPsePortAveragePower
 | 
						|
                      Integer32,
 | 
						|
              hh3cPsePortCurrentPower
 | 
						|
                      Integer32,
 | 
						|
              hh3cPsePortPowerLimit
 | 
						|
                      Integer32,
 | 
						|
              hh3cPsePortProfileIndex
 | 
						|
                      Integer32
 | 
						|
      }
 | 
						|
 | 
						|
hh3cPsePortFaultDescription OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object supports the fault category of the IETF Power MIB [1]
 | 
						|
             pethPsePortDetectionStatus object.  A textual description
 | 
						|
             containing more information about the nature of this fault is
 | 
						|
             provided by this object.  Typically this will detail the precise
 | 
						|
             PoE hardware state which is causing the pethPsePortDetectionStatus
 | 
						|
             object to be in the 'fault' state.
 | 
						|
             It is a DisplayString of up to 255 characters."
 | 
						|
      ::= { hh3cPsePortEntry 2 }
 | 
						|
 | 
						|
 | 
						|
hh3cPsePortPeakPower OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the peak power which has been consumed by
 | 
						|
             the port.  It is defined as the highest measured value of power
 | 
						|
             in milliWatts that has been consumed by the port.  Its value
 | 
						|
             is only reset when link is lost, the port is PoE disabled or
 | 
						|
             when it is manually reset by the user asspecified below.
 | 
						|
             It is a read/write integer value with units of milliWatts.
 | 
						|
             Writing a value of zero to this object resets its value
 | 
						|
             to zero.  Writing any other value to this object has no
 | 
						|
             effect on its value and an error is returned."
 | 
						|
      ::= { hh3cPsePortEntry 3 }
 | 
						|
 | 
						|
 | 
						|
hh3cPsePortAveragePower OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the average power which has been consumed
 | 
						|
             by the port.  This object is a read/write integer value with
 | 
						|
             units of milliWatts.  Writing a value of zero to this object
 | 
						|
             resets its value to zero.  Writing any other value to this
 | 
						|
             object has no effect on its value and an error is returned."
 | 
						|
      ::= { hh3cPsePortEntry 4 }
 | 
						|
 | 
						|
 | 
						|
hh3cPsePortCurrentPower OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
              "The object specifies the power currently being consumed by the port.
 | 
						|
              It is a read only integer value with units of milliWatts."
 | 
						|
      ::= { hh3cPsePortEntry 5 }
 | 
						|
 | 
						|
 | 
						|
hh3cPsePortPowerLimit OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
              "The object specifies the power limit set for this port.
 | 
						|
              The PSE will not supply more than this level of power to the
 | 
						|
              specified port.
 | 
						|
              It is a read/write integer value with units of milliWatts."
 | 
						|
      ::= { hh3cPsePortEntry 6 }
 | 
						|
 | 
						|
hh3cPsePortProfileIndex OBJECT-TYPE
 | 
						|
      SYNTAX Integer32 (0..100)
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Indicates the power profile which is currently associated
 | 
						|
             with this port.  This object references the corresponding
 | 
						|
             hh3cPseProfileIndex object in the power profiles table.  A
 | 
						|
             value of zero is a special case and indicates that no
 | 
						|
             power profile is currently associated with this port.  When
 | 
						|
             hh3cPseProfileIndex is set to an index of existent profile,
 | 
						|
             pethPsePortPowerPairs, pethPsePortPowerPriority,
 | 
						|
             pethPsePortAdminEnable and hh3cPsePortPowerLimit will be
 | 
						|
             set to the same as corresponding value.  PethPsePortPowerPairs,
 | 
						|
             pethPsePortPowerPriority and pethPsePortAdminEnable are objects
 | 
						|
             of rfc3621-Power-Ethernet.mib."
 | 
						|
      ::= { hh3cPsePortEntry 7 }
 | 
						|
 | 
						|
 | 
						|
hh3cMainPseTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cMainPseEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
              "Description."
 | 
						|
      ::= { hh3cPowerEthernetExt 2 }
 | 
						|
 | 
						|
 | 
						|
hh3cMainPseEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cMainPseEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The pethMainPseGroupIndex is imported from the IETF Power MIB
 | 
						|
             and uniquely identifies the group containing the port to which
 | 
						|
             power ethernet PSE is connected.  Group means (box in the stack,
 | 
						|
             module in a rack) and the value 1 MUST be used for non-modular
 | 
						|
             devices."
 | 
						|
      INDEX { pethMainPseGroupIndex }
 | 
						|
      ::= { hh3cMainPseTable 1 }
 | 
						|
 | 
						|
 | 
						|
Hh3cMainPseEntry ::=
 | 
						|
      SEQUENCE {
 | 
						|
              hh3cMainPsePowerLimit
 | 
						|
                         Integer32,
 | 
						|
              hh3cMainPseAveragePower
 | 
						|
                         Integer32,
 | 
						|
              hh3cMainPsePeakPower
 | 
						|
                         Integer32,
 | 
						|
              hh3cMainGuaranteedPowerRemaining
 | 
						|
                         Integer32,
 | 
						|
              hh3cMainPsePriorityMode
 | 
						|
                         INTEGER,
 | 
						|
              hh3cMainPseLegacy
 | 
						|
                         INTEGER,
 | 
						|
              hh3cMainPsePowerPriority
 | 
						|
                         INTEGER
 | 
						|
              }
 | 
						|
 | 
						|
hh3cMainPsePowerLimit OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the power limit set for the unit as a whole.
 | 
						|
             The PoE unit will already have a nominal power defined by the
 | 
						|
             IETF Power MIB [1] pethMainPsePower object.  This OPTIONAL object
 | 
						|
             specifies a further limit to this nominal power value.  This may
 | 
						|
             be useful to control the thermals of the unit, or for internal
 | 
						|
             testing purposes.  One possible use for this object may be to lower
 | 
						|
             the power consumption of the unit if one or more of the internal
 | 
						|
             fans have broken.  It is a read/write integer value with units of
 | 
						|
             Watts (note - Watts is chosen instead of milliWatts here since
 | 
						|
             the IETF Power MIB [1] measures unit based parameters, such as
 | 
						|
             the pethMainPsePower object, in units of Watts)."
 | 
						|
      ::= { hh3cMainPseEntry 1 }
 | 
						|
 | 
						|
 | 
						|
hh3cMainPseAveragePower OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the average power which has been consumed
 | 
						|
             by the port.  It is a read/write integer value with units of
 | 
						|
             Watts (note - Watts is chosen instead of milliWatts here since
 | 
						|
             the IETF Power MIB [1] measures unit based parameters, such as
 | 
						|
             the pethMainPsePower object, in units of Watts).  Writing a value
 | 
						|
             of zero to this object resets its value to zero.  Writing any
 | 
						|
             other value to this object has no effect on its value and an error
 | 
						|
             is returned."
 | 
						|
      ::= { hh3cMainPseEntry 2 }
 | 
						|
 | 
						|
 | 
						|
hh3cMainPsePeakPower OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the peak power which has been consumed for PoE.
 | 
						|
             It is defined as the highest measured value of power in milliWatts
 | 
						|
             that has been consumed at any one point in time by the sum of the PoE
 | 
						|
             ports.  Its value is only reset when the unit is powered on or when
 | 
						|
             it is manually reset by the user as specifiedbelow.  It is a read/write
 | 
						|
             integer value with units of Watts (note - Watts is chosen instead of
 | 
						|
             milliWatts here since the IETF Power MIB [1] measures unit based
 | 
						|
             parameters, such as the pethMainPsePower object, in units of Watts).
 | 
						|
             Writing a value of zero to this object resets its value to zero.
 | 
						|
             Writing any other value to this object has noeffect on its value
 | 
						|
             and an error is returned."
 | 
						|
      ::= { hh3cMainPseEntry 3 }
 | 
						|
 | 
						|
 | 
						|
hh3cMainGuaranteedPowerRemaining OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the amount of power remaining in the guaranteed
 | 
						|
             power pool.  Each time a port is placed into guaranteed mode it
 | 
						|
             reserves a set amount of power out of the total guaranteed power
 | 
						|
             pool for the system.  This intention of this object is to give the
 | 
						|
             client of this MIB (whether that be the CLI or the Web interface or
 | 
						|
             the end user) an indication of how many ports can still be placed
 | 
						|
             into guaranteed mode.  It is a read only integer value with units of
 | 
						|
             Watts(note - Watts is chosen instead of milliWatts here since the
 | 
						|
             IETF Power MIB [1] measures unit based parameters,such as the
 | 
						|
             pethMainPsePower object, in units of Watts)."
 | 
						|
      ::= { hh3cMainPseEntry 4 }
 | 
						|
 | 
						|
 | 
						|
hh3cMainPsePriorityMode OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER   {
 | 
						|
              disconnection(0),
 | 
						|
              non-disconnection(1)
 | 
						|
              }
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Describes or controls the priority mode on slot which must be
 | 
						|
             enabled firstly.  When a new board is inserted, and the power is
 | 
						|
             over-load, a value of disconnection(0) means that the power will
 | 
						|
             stop supply to the low priority slot ; A value of non-disconnection(1)
 | 
						|
             means that the slot still supply when a new board is inserted, and
 | 
						|
             the power is over-load too."
 | 
						|
      ::= { hh3cMainPseEntry 5 }
 | 
						|
 | 
						|
hh3cMainPseLegacy OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER   {
 | 
						|
             enable(0),
 | 
						|
             disable(1)
 | 
						|
              }
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Describes or controls the legacy mode on slot which must be enabled
 | 
						|
             firstly.  Legacy mode: standard or nonstandard PD detection mode."
 | 
						|
      ::= { hh3cMainPseEntry 6 }
 | 
						|
 | 
						|
hh3cMainPsePowerPriority OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER   {
 | 
						|
             critical(1),
 | 
						|
             high(2),
 | 
						|
             low(3)
 | 
						|
              }
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Describes or controls the priority of the PSE.  The priority
 | 
						|
             will be used by the PSE policy to prevent from power overloading.
 | 
						|
             If the priority of PSE is set to critical, the PSE will turn into
 | 
						|
             guaranteed mode.  The priority could be used by a control mechanism
 | 
						|
             that prevents power overloading by disconnecting PSEs with lower
 | 
						|
             power priority.  PSEs that connect devices critical to the
 | 
						|
             application should be set to higher priority."
 | 
						|
      ::= { hh3cMainPseEntry 7 }
 | 
						|
 | 
						|
-- Power Profile PSE table
 | 
						|
hh3cPseProfilesTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cPseProfilesEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "A table of objects representing a set of power profiles.
 | 
						|
             Power profiles can be applied to PoE ports, which have the
 | 
						|
             effect of automatically setting the priority, power limit
 | 
						|
             and PoE enable MIB objects to the values specified in the
 | 
						|
             power profile."
 | 
						|
      ::= { hh3cPowerEthernetExt 7 }
 | 
						|
 | 
						|
hh3cPseProfilesEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPseProfilesEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "A set of objects that display and control the Main power of a PSE."
 | 
						|
      INDEX    { hh3cPseProfileIndex }
 | 
						|
      ::= { hh3cPseProfilesTable 1 }
 | 
						|
 | 
						|
Hh3cPseProfilesEntry ::= SEQUENCE {
 | 
						|
             hh3cPseProfileIndex     Integer32,
 | 
						|
             hh3cPseProfileName      DisplayString,
 | 
						|
             hh3cPseProfilePowerMode      INTEGER,
 | 
						|
             hh3cPseProfilePowerLimit     Integer32,
 | 
						|
             hh3cPseProfilePriority       INTEGER,
 | 
						|
             hh3cPseProfilePairs          INTEGER,
 | 
						|
             hh3cPseProfileApplyNum       Integer32,
 | 
						|
             hh3cPseProfileRowStatus      RowStatus
 | 
						|
                }
 | 
						|
 | 
						|
hh3cPseProfileIndex OBJECT-TYPE
 | 
						|
      SYNTAX Integer32 (1..100)
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The index of the profile.  This uniquely allow the profile to be
 | 
						|
             identified."
 | 
						|
      ::= { hh3cPseProfilesEntry 1 }
 | 
						|
 | 
						|
hh3cPseProfileName OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString (SIZE(1..15))
 | 
						|
      MAX-ACCESS read-create
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
            "Assigns the profile a name with which the settings
 | 
						|
            can be assiciated with.  For example, 'NBX Phone'."
 | 
						|
      ::= { hh3cPseProfilesEntry 2 }
 | 
						|
 | 
						|
hh3cPseProfilePowerMode OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER {
 | 
						|
                powerDisabled (1),
 | 
						|
                powerEnabled (2)
 | 
						|
               }
 | 
						|
      MAX-ACCESS read-create
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The power mode associated with this power profile.  There
 | 
						|
             are two possible power modes as follows: powerDisabled,
 | 
						|
             powerEnabled.  When a power profile is applied to a PSE port,
 | 
						|
             this value dictates the settings of the ports pethPsePortPowerPriority
 | 
						|
             and pethPsePortAdminEnable objects."
 | 
						|
      ::= { hh3cPseProfilesEntry 3 }
 | 
						|
 | 
						|
hh3cPseProfilePowerLimit OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-create
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The power limit to be applied to the ports hh3cPsePortPowerLimit
 | 
						|
              object when the profile is applied to the PSE port.  Expressed in
 | 
						|
              milliWatts."
 | 
						|
      ::= { hh3cPseProfilesEntry 4 }
 | 
						|
 | 
						|
hh3cPseProfilePriority OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER   {
 | 
						|
                critical(1),
 | 
						|
                high(2),
 | 
						|
                low(3)
 | 
						|
               }
 | 
						|
      MAX-ACCESS read-create
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This object controls the priority of the port from the point of
 | 
						|
             view of a power management algorithm.  The priority that is set
 | 
						|
             by this variable could be used by a control mechanism that
 | 
						|
             prevents over current situations by disconnecting first ports
 | 
						|
             with lower power priority.  Ports that connect devices critical
 | 
						|
             to the operation of the network - like the E911 telephones
 | 
						|
             ports - should be set to higher priority."
 | 
						|
      ::= { hh3cPseProfilesEntry 5 }
 | 
						|
 | 
						|
hh3cPseProfilePairs OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER   {
 | 
						|
                signal(1),
 | 
						|
                spare(2)
 | 
						|
                }
 | 
						|
      MAX-ACCESS read-create
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Describes or controls the pairs in use.  If the value of
 | 
						|
             pethPsePortPowerPairsControl is true, this object is writable.
 | 
						|
             A value of signal(1) means that the signal pairs only are in use.
 | 
						|
             A value of spare(2) means that the spare pairs only are in use."
 | 
						|
      REFERENCE
 | 
						|
             "IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
 | 
						|
      ::= { hh3cPseProfilesEntry 6 }
 | 
						|
 | 
						|
hh3cPseProfileApplyNum OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The number of this profile which has been applied.
 | 
						|
             If hh3cPseProfileApplyNum is not zero, user can't
 | 
						|
             change the current line."
 | 
						|
      ::= { hh3cPseProfilesEntry 7 }
 | 
						|
 | 
						|
hh3cPseProfileRowStatus OBJECT-TYPE
 | 
						|
      SYNTAX RowStatus
 | 
						|
      MAX-ACCESS read-create
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The status of this classifier.
 | 
						|
             If hh3cPseProfileApplyNum is not zero, user can't
 | 
						|
             delete the current line."
 | 
						|
      ::= { hh3cPseProfilesEntry 8 }
 | 
						|
 | 
						|
hh3cPseAutoDetectActive OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                notSupported(1),
 | 
						|
                disabled(2),
 | 
						|
                enabled(3)
 | 
						|
                }
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies whether the device auto-detection feature is
 | 
						|
             active.  If this object is set to Active, and a known powered device
 | 
						|
             is detected, then the port will automatically switch to Auto-Guaranteed
 | 
						|
             mode.  This is a stackwide object (ie. it is not referenced by
 | 
						|
             group index)."
 | 
						|
      ::= { hh3cPowerEthernetExt 3 }
 | 
						|
 | 
						|
hh3cPsePowerMaxValue OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the max poe power for lanswitch.
 | 
						|
             The value should between the power currently and the max power."
 | 
						|
      ::= { hh3cPowerEthernetExt 5 }
 | 
						|
 | 
						|
hh3cPsePolicyMode OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
              {
 | 
						|
              disabled(1),
 | 
						|
              priority(2)
 | 
						|
              }
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The PSE policy only applies to the situation that when a new
 | 
						|
             board (PSE) is inserted, and the power is overload.
 | 
						|
             A value of priority(2) means that the power will stop supplying
 | 
						|
             to the low priority PSE.  About PSE priority, please refer to
 | 
						|
             hh3cMainPsePowerPriority.  A value of disabled(1) means that the
 | 
						|
             power will stop supplying to the new inserted PSE.  The default
 | 
						|
             value of this object is disabled(1)."
 | 
						|
      ::= { hh3cPowerEthernetExt 9 }
 | 
						|
 | 
						|
hh3cPDPolicyMode OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
              {
 | 
						|
              disabled(1),
 | 
						|
              priority(2)
 | 
						|
              }
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The PD policy only applies to the situation that when a new
 | 
						|
             PD is inserted, and the power of PSE is overload.
 | 
						|
             A value of priority(2) means that the power will stop supplying
 | 
						|
             to the low priority port PD.  About port priority, please refer
 | 
						|
             to pethPsePortPowerPriority.  A value of disabled(1) means that
 | 
						|
             the slot stop supplying to the new inserted PD.  The default
 | 
						|
             value of this object is disabled(1)."
 | 
						|
      ::= { hh3cPowerEthernetExt 10 }
 | 
						|
 | 
						|
hh3cpseportNotification  OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 6 }
 | 
						|
 | 
						|
-- Notification  Control  Objects
 | 
						|
 | 
						|
hh3cpsePDChangeNotification NOTIFICATION-TYPE
 | 
						|
      OBJECTS { pethPsePortDetectionStatus }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates if PD has been inserted or pulled out."
 | 
						|
      ::= { hh3cpseportNotification 1 }
 | 
						|
 | 
						|
hh3cPOEDisconnectNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleDisconnect }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the POE power module does not disconnect."
 | 
						|
      ::= { hh3cpseportNotification 2 }
 | 
						|
 | 
						|
hh3cPOEInputErrorNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleInputError }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the POE power module input error."
 | 
						|
      ::= { hh3cpseportNotification 3 }
 | 
						|
 | 
						|
hh3cPOEOutputErrorNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOutputError }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the POE power module output error."
 | 
						|
      ::= { hh3cpseportNotification 4 }
 | 
						|
 | 
						|
hh3cPOEOverVoltageNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverVoltage }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the POE power module overruns the
 | 
						|
             voltage limit."
 | 
						|
      ::= { hh3cpseportNotification 5 }
 | 
						|
 | 
						|
hh3cPOEOverTempNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverTemp }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the POE power module overruns the
 | 
						|
             temperature limit."
 | 
						|
      ::= { hh3cpseportNotification 6 }
 | 
						|
 | 
						|
hh3cPOEFanErrorNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleFanError }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the POE power module fan error."
 | 
						|
      ::= { hh3cpseportNotification 7 }
 | 
						|
 | 
						|
hh3cPOEModuleShutdownNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleShutdown }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the POE power module is closed."
 | 
						|
      ::= { hh3cpseportNotification 8 }
 | 
						|
 | 
						|
hh3cPOECurRestrictedNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleCurRestricted }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the POE power module current is restricted."
 | 
						|
      ::= { hh3cpseportNotification 9 }
 | 
						|
 | 
						|
hh3cPOEACSwitchNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEACSwitchStateIndex, hh3cPOEACSwitchState }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the AC input switch alarm of this POE power."
 | 
						|
      ::= { hh3cpseportNotification 10 }
 | 
						|
 | 
						|
hh3cPOEACInCurANotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEInCurAState }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the AC input current A alarm state of
 | 
						|
             this POE power."
 | 
						|
      ::= { hh3cpseportNotification 11 }
 | 
						|
 | 
						|
hh3cPOEACInCurBNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEInCurBState }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the AC input current B alarm state of
 | 
						|
             this POE power."
 | 
						|
      ::= { hh3cpseportNotification 12 }
 | 
						|
 | 
						|
hh3cPOEACInCurCNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEInCurCState }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the AC input current C alarm state of
 | 
						|
             this POE power."
 | 
						|
      ::= { hh3cpseportNotification 13 }
 | 
						|
 | 
						|
hh3cPOEACSwitchVolABNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolAB}
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the AC input voltage AB alarm state of
 | 
						|
             this POE power."
 | 
						|
      ::= { hh3cpseportNotification 14 }
 | 
						|
 | 
						|
hh3cPOEACSwitchVolBCNotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolBC}
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the AC input voltage BC alarm state of
 | 
						|
             this POE power."
 | 
						|
      ::= { hh3cpseportNotification 15 }
 | 
						|
 | 
						|
hh3cPOEACSwitchVolCANotification  NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolCA }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the AC input voltage CA alarm state of
 | 
						|
             this POE power."
 | 
						|
      ::= { hh3cpseportNotification 16 }
 | 
						|
 | 
						|
hh3cPOEDCOutVolNotification NOTIFICATION-TYPE
 | 
						|
      OBJECTS { hh3cPOEDCOutStateIndex, hh3cPOEDCOutDCVolAlarm }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the DC output alarm of this POE power."
 | 
						|
      ::= { hh3cpseportNotification 17 }
 | 
						|
 | 
						|
hh3cPOEShutdownNotification NOTIFICATION-TYPE
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "This notification indicates the whole POE power has been shutdown."
 | 
						|
      ::= { hh3cpseportNotification 18 }
 | 
						|
hh3cPseComformance OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 4 }
 | 
						|
 | 
						|
hh3cPseCompliances OBJECT IDENTIFIER ::= { hh3cPseComformance 1 }
 | 
						|
 | 
						|
hh3cPseCompliance MODULE-COMPLIANCE
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Description."
 | 
						|
      MODULE  -- this module
 | 
						|
      MANDATORY-GROUPS {    hh3cPsePortGroup,
 | 
						|
                            hh3cMainPseGroup,
 | 
						|
                            hh3cPseScalarGroup,
 | 
						|
                            hh3cPsePDNotificationGroup
 | 
						|
                       }
 | 
						|
      GROUP hh3cPseProfilesGroup
 | 
						|
      DESCRIPTION
 | 
						|
             "This group is mandatory only for executing POE commands as a batch."
 | 
						|
      ::= { hh3cPseCompliances 1 }
 | 
						|
 | 
						|
hh3cPseGroup OBJECT IDENTIFIER ::= { hh3cPseComformance 2 }
 | 
						|
 | 
						|
hh3cPsePortGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPsePortProfileIndex, hh3cPsePortPowerLimit, hh3cPsePortCurrentPower,
 | 
						|
                hh3cPsePortAveragePower, hh3cPsePortPeakPower, hh3cPsePortFaultDescription,
 | 
						|
                hh3cMainPsePriorityMode
 | 
						|
              }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "A collection of objects should be supported at the same time."
 | 
						|
      ::= { hh3cPseGroup 1 }
 | 
						|
 | 
						|
hh3cMainPseGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cMainPsePowerLimit, hh3cMainPseAveragePower, hh3cMainPsePeakPower,
 | 
						|
                hh3cMainGuaranteedPowerRemaining }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "A collection of objects should be supported at the same time."
 | 
						|
      ::= { hh3cPseGroup 2 }
 | 
						|
 | 
						|
hh3cPseScalarGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPseAutoDetectActive, hh3cPsePowerMaxValue, hh3cPsePolicyMode ,
 | 
						|
                hh3cPDPolicyMode }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "A collection of scalar objects supported."
 | 
						|
      ::= { hh3cPseGroup 3 }
 | 
						|
 | 
						|
hh3cPsePDNotificationGroup NOTIFICATION-GROUP
 | 
						|
      NOTIFICATIONS { hh3cpsePDChangeNotification }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "PD Change Notification."
 | 
						|
      ::= { hh3cPseGroup 4 }
 | 
						|
 | 
						|
hh3cPseProfilesGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPseProfileName, hh3cPseProfilePowerMode,
 | 
						|
                hh3cPseProfilePowerLimit, hh3cPseProfilePriority,
 | 
						|
                hh3cPseProfilePairs, hh3cPseProfileApplyNum, hh3cPseProfileRowStatus}
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "A collection of objects should be supported at the same time."
 | 
						|
      ::= { hh3cPseGroup 5 }
 | 
						|
 | 
						|
hh3cPOEPowerThresholdLimitGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPOEThresholdACMimimum, hh3cPOEThresholdACMaximum,
 | 
						|
                hh3cPOEThresholdDCMinimum, hh3cPOEThresholdDCMaximum }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Power threshold limits group."
 | 
						|
      ::= { hh3cPseGroup 6 }
 | 
						|
 | 
						|
hh3cPOEPowerSupInfoGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPOEPowerType, hh3cPOEPowerModuleNum, hh3cPOESupervisionModuleName,
 | 
						|
                hh3cPOESMMajorVersion, hh3cPOESMMinorVersion, hh3cPOESMFactorName}
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The basic Power information group."
 | 
						|
      ::= { hh3cPseGroup 7 }
 | 
						|
 | 
						|
hh3cPOEPowerDCOutStateGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPOEDCOutStateModuleNum }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The DC out power state group."
 | 
						|
      ::= { hh3cPseGroup 8 }
 | 
						|
 | 
						|
hh3cPOEPowerDCOutInfoGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPOEDCOutCurNum }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The power AC input switch information group"
 | 
						|
      ::= { hh3cPseGroup 9 }
 | 
						|
 | 
						|
hh3cPOEPowerACSwitchStateModuleGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPOEACSwitchStateModuleNum}
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "PD Change Notification."
 | 
						|
      ::= { hh3cPseGroup 10 }
 | 
						|
 | 
						|
hh3cPOEPowerInCurStateGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPOEInCurStateModuleNum, hh3cPOEInCurAState, hh3cPOEInCurBState,
 | 
						|
                hh3cPOEInCurCState}
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "PD Change Notification."
 | 
						|
      ::= { hh3cPseGroup 11 }
 | 
						|
 | 
						|
hh3cPOEPowerAlarmStateGroup OBJECT-GROUP
 | 
						|
      OBJECTS { hh3cPOEAlarmStateModuleNum }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
              "PD Change Notification."
 | 
						|
      ::= { hh3cPseGroup 12 }
 | 
						|
 | 
						|
ACAlarmState ::= TEXTUAL-CONVENTION
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
           "AC Alarm State."
 | 
						|
      SYNTAX INTEGER{
 | 
						|
                normal     (1),
 | 
						|
                underLimit (2),
 | 
						|
                aboveLimit (3),
 | 
						|
                lackPhrase (4),
 | 
						|
                fuseBroken (5),
 | 
						|
                switchOff  (6),
 | 
						|
                otherError (7)
 | 
						|
                   }
 | 
						|
 | 
						|
DCAlarmState ::= TEXTUAL-CONVENTION
 | 
						|
     STATUS current
 | 
						|
     DESCRIPTION
 | 
						|
         "DC Alarm State."
 | 
						|
     SYNTAX INTEGER{
 | 
						|
                normal     (1),
 | 
						|
                underLimit (2),
 | 
						|
                aboveLimit (3),
 | 
						|
                fuseBroken (4),
 | 
						|
                switchOff  (5),
 | 
						|
                otherError (6)
 | 
						|
                   }
 | 
						|
 | 
						|
SwitchState ::= TEXTUAL-CONVENTION
 | 
						|
     STATUS current
 | 
						|
     DESCRIPTION
 | 
						|
        "Switch State."
 | 
						|
SYNTAX INTEGER   {
 | 
						|
               on            (1),
 | 
						|
               off           (2),
 | 
						|
               highVoltInput (3),
 | 
						|
               lowVoltInput  (4)
 | 
						|
                  }
 | 
						|
 | 
						|
ModuleAlarmState ::= TEXTUAL-CONVENTION
 | 
						|
   STATUS current
 | 
						|
   DESCRIPTION
 | 
						|
      "Module Alarm State."
 | 
						|
   SYNTAX INTEGER   {
 | 
						|
                    normal (1),
 | 
						|
                    alarm  (2)
 | 
						|
                      }
 | 
						|
 | 
						|
hh3cPOEPowerObjects OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 8 }
 | 
						|
 | 
						|
hh3cPOEThresholdLimitObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 1 }
 | 
						|
 | 
						|
hh3cPOEThresholdACMimimum OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..10))
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Input threshold AC minimum.
 | 
						|
             It is a read-write node.
 | 
						|
             The value of this node is 'OCTET STRING',
 | 
						|
             it is used to describe a float value.
 | 
						|
             So this string should fit the following rule:
 | 
						|
             1. This string should be terminated by '\0';
 | 
						|
             2. Every characters should be number or radix point;
 | 
						|
             3. The radix point should occur only once, and it should not
 | 
						|
             be the first or the last character of the string.
 | 
						|
             The value of this node should be smaller than 264.0V and larger than 90.0V.
 | 
						|
             And it should be smaller than the hh3cPOEThresholdACMaximum."
 | 
						|
      ::= { hh3cPOEThresholdLimitObjs 1 }
 | 
						|
 | 
						|
hh3cPOEThresholdACMaximum OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..10))
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Input threshold AC maximum.
 | 
						|
             It is a read-write node.
 | 
						|
             The value of this node is 'OCTET STRING',
 | 
						|
             it is used to describe a float value.
 | 
						|
             So this string should fit the following rule:
 | 
						|
             1. This string should be terminated by '\0';
 | 
						|
             2. Every characters should be number or radix point;
 | 
						|
             3. The radix point should occur only once, and it should not
 | 
						|
             be the first or the last character of the string.
 | 
						|
             It should be smaller than 264.0V and larger than 90.0V.
 | 
						|
             And it should be larger than the hh3cPOEThresholdACMinimum."
 | 
						|
      ::= { hh3cPOEThresholdLimitObjs 2 }
 | 
						|
 | 
						|
hh3cPOEThresholdDCMinimum OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..10))
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Input threshold DC minimum.
 | 
						|
             It is a read-write node.
 | 
						|
             The value of this node is 'OCTET STRING',
 | 
						|
             it is used to describe a float value.
 | 
						|
             So this string should fit the following rule:
 | 
						|
             1. This string should be terminated by '\0';
 | 
						|
             2. Every characters should be number or radix point;
 | 
						|
             3. The radix point should occur only once, and it should not
 | 
						|
             be the first or the last character of the string.
 | 
						|
             It should be smaller than 47.0V and larger than 45.0V."
 | 
						|
      ::= { hh3cPOEThresholdLimitObjs 3 }
 | 
						|
 | 
						|
hh3cPOEThresholdDCMaximum OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..10))
 | 
						|
      MAX-ACCESS read-write
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "Input threshold DC maximum.
 | 
						|
             It is a read-write node.
 | 
						|
             The value of this node is 'OCTET STRING',
 | 
						|
             it is used to describe a float value.
 | 
						|
             So this string should fit the following rule:
 | 
						|
             1. This string should be terminated by '\0';
 | 
						|
             2. Every characters should be number or radix point;
 | 
						|
             3. The radix point should occur only once, and it should not
 | 
						|
             be the first or the last character of the string.
 | 
						|
             It should be smaller than 57.0V and larger than 55.0V."
 | 
						|
      ::= { hh3cPOEThresholdLimitObjs 4 }
 | 
						|
 | 
						|
hh3cPOESupModuleInfoObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 2 }
 | 
						|
 | 
						|
hh3cPOEPowerType OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..127))
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The type of the power."
 | 
						|
      ::= { hh3cPOESupModuleInfoObjs 1 }
 | 
						|
 | 
						|
hh3cPOEPowerModuleNum OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The number of the power modules."
 | 
						|
      ::= { hh3cPOESupModuleInfoObjs 2 }
 | 
						|
 | 
						|
hh3cPOESupervisionModuleName OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..127))
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the Supervision Module name on this POE power."
 | 
						|
      ::= { hh3cPOESupModuleInfoObjs 3 }
 | 
						|
 | 
						|
hh3cPOESMMajorVersion OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the high byte of the monitor module version."
 | 
						|
      ::= { hh3cPOESupModuleInfoObjs 4 }
 | 
						|
 | 
						|
hh3cPOESMMinorVersion OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the low byte of the monitor module version."
 | 
						|
      ::= { hh3cPOESupModuleInfoObjs 5 }
 | 
						|
 | 
						|
hh3cPOESMFactorName OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..127))
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the name of the manufactor."
 | 
						|
      ::= { hh3cPOESupModuleInfoObjs 6 }
 | 
						|
 | 
						|
hh3cPOEModuleInfoTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cPOEModuleInfoEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The table of the module information on this POE power."
 | 
						|
      ::= { hh3cPOESupModuleInfoObjs 7 }
 | 
						|
 | 
						|
hh3cPOEModuleInfoEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPOEModuleInfoEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The entry of the module information on this POE power."
 | 
						|
      INDEX { hh3cPOEModuleIndex }
 | 
						|
      ::= { hh3cPOEModuleInfoTable 1 }
 | 
						|
 | 
						|
Hh3cPOEModuleInfoEntry ::=
 | 
						|
      SEQUENCE {
 | 
						|
                 hh3cPOEModuleIndex
 | 
						|
                         Integer32,
 | 
						|
                 hh3cPOEModuleID
 | 
						|
                         Integer32,
 | 
						|
                 hh3cPOEModuleInfoPower
 | 
						|
                         Integer32,
 | 
						|
                 hh3cPOEModuleHardVerInfo
 | 
						|
                         OCTET STRING
 | 
						|
                }
 | 
						|
 | 
						|
hh3cPOEModuleIndex OBJECT-TYPE
 | 
						|
      SYNTAX Integer32 (1..2147483647)
 | 
						|
      MAX-ACCESS accessible-for-notify
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The index of the current module on this POE power.
 | 
						|
             It is also the index of hh3cPOEModuleInfoTable.
 | 
						|
             The range of this node is from 1 to hh3cPOEPowerModuleNum."
 | 
						|
      ::= { hh3cPOEModuleInfoEntry 1 }
 | 
						|
 | 
						|
hh3cPOEModuleID OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The ID of the current module on this POE power."
 | 
						|
      ::= { hh3cPOEModuleInfoEntry 2 }
 | 
						|
 | 
						|
hh3cPOEModuleInfoPower OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The power of the current module on this POE power."
 | 
						|
      ::= { hh3cPOEModuleInfoEntry 3 }
 | 
						|
 | 
						|
hh3cPOEModuleHardVerInfo OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..127))
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The hardware version information of the current module on this POE power."
 | 
						|
      ::= { hh3cPOEModuleInfoEntry 4 }
 | 
						|
 | 
						|
hh3cPOEDCOutStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 3 }
 | 
						|
 | 
						|
hh3cPOEDCOutStateModuleNum OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The module number on this POE power.
 | 
						|
             It is the maximum of the hh3cPOEDCOutStateIndex."
 | 
						|
      ::= { hh3cPOEDCOutStateObjects 1 }
 | 
						|
 | 
						|
hh3cPOEDCOutStateTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cPOEDCOutStateEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The table of DC output power state on this POE power."
 | 
						|
      ::= { hh3cPOEDCOutStateObjects 2 }
 | 
						|
 | 
						|
hh3cPOEDCOutStateEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPOEDCOutStateEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The entry of the DC output power state on this POE power."
 | 
						|
      INDEX { hh3cPOEDCOutStateIndex }
 | 
						|
      ::= { hh3cPOEDCOutStateTable 1 }
 | 
						|
 | 
						|
      Hh3cPOEDCOutStateEntry ::=
 | 
						|
              SEQUENCE {
 | 
						|
                       hh3cPOEDCOutStateIndex
 | 
						|
                               Integer32,
 | 
						|
                       hh3cPOEDCOutDCVolAlarm
 | 
						|
                               DCAlarmState
 | 
						|
                    }
 | 
						|
 | 
						|
hh3cPOEDCOutStateIndex OBJECT-TYPE
 | 
						|
      SYNTAX Integer32 (1..2147483647)
 | 
						|
      MAX-ACCESS accessible-for-notify
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The index of the DC output power state on this POE power.
 | 
						|
             The range of this node is from 1 to hh3cPOEDCOutStateModuleNum."
 | 
						|
      ::= { hh3cPOEDCOutStateEntry 1 }
 | 
						|
 | 
						|
hh3cPOEDCOutDCVolAlarm OBJECT-TYPE
 | 
						|
      SYNTAX DCAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The DC output alarm of the DC output power state on this POE power.
 | 
						|
             The value of this node will be the following values:
 | 
						|
                                 normal     (1),
 | 
						|
                                 underLimit (2),
 | 
						|
                                 aboveLimit (3),
 | 
						|
                                 fuseBroken (4),
 | 
						|
                                 switchOff  (5),
 | 
						|
                                 otherError (6)."
 | 
						|
      ::= { hh3cPOEDCOutStateEntry 2 }
 | 
						|
 | 
						|
hh3cPOEDCOutInfoObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 4 }
 | 
						|
 | 
						|
hh3cPOEDCOutCurNum OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The number of DC output current on this POE power.
 | 
						|
             It is the maximum of hh3cPOEDCOutInfoIndex."
 | 
						|
      ::= { hh3cPOEDCOutInfoObjects 1 }
 | 
						|
 | 
						|
hh3cPOEDCOutInfoTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cPOEDCOutInfoEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The table of the DC output information on this POE power."
 | 
						|
      ::= { hh3cPOEDCOutInfoObjects 2 }
 | 
						|
 | 
						|
hh3cPOEDCOutInfoEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPOEDCOutInfoEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The entry of the DC output information on this POE power."
 | 
						|
      INDEX { hh3cPOEDCOutInfoIndex }
 | 
						|
      ::= { hh3cPOEDCOutInfoTable 1 }
 | 
						|
 | 
						|
Hh3cPOEDCOutInfoEntry ::=
 | 
						|
      SEQUENCE {
 | 
						|
                hh3cPOEDCOutInfoIndex
 | 
						|
                        Integer32,
 | 
						|
                hh3cPOEDCOutVol
 | 
						|
                        OCTET STRING,
 | 
						|
                hh3cPOEDCOutInfoLoadCur
 | 
						|
                        OCTET STRING
 | 
						|
              }
 | 
						|
 | 
						|
hh3cPOEDCOutInfoIndex OBJECT-TYPE
 | 
						|
      SYNTAX Integer32 (1..2147483647)
 | 
						|
      MAX-ACCESS accessible-for-notify
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The index of the DC output information on this POE POWER.
 | 
						|
             The range of this node is from 1 to hh3cPOEDCOutCurNum."
 | 
						|
      ::= { hh3cPOEDCOutInfoEntry 1 }
 | 
						|
 | 
						|
hh3cPOEDCOutVol OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..10))
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The DC output voltage of the current DC output on this POE power."
 | 
						|
      ::= { hh3cPOEDCOutInfoEntry 2 }
 | 
						|
 | 
						|
hh3cPOEDCOutInfoLoadCur OBJECT-TYPE
 | 
						|
      SYNTAX OCTET STRING (SIZE (1..10))
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The total load current of the current DC output on this POE power."
 | 
						|
      ::= { hh3cPOEDCOutInfoEntry 3 }
 | 
						|
 | 
						|
hh3cPOEACSwitchStateModuleObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 5 }
 | 
						|
 | 
						|
hh3cPOEACSwitchStateModuleNum OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The number of the AC swtich state module on this POE power.
 | 
						|
             It is the maximum of hh3cPOEACSwitchStateIndex."
 | 
						|
      ::= { hh3cPOEACSwitchStateModuleObjs 1 }
 | 
						|
 | 
						|
hh3cPOEACSwitchStateTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cPOEACSwitchStateEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The table of the AC switch state on this POE power."
 | 
						|
      ::= { hh3cPOEACSwitchStateModuleObjs 2 }
 | 
						|
 | 
						|
hh3cPOEACSwitchStateEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPOEACSwitchStateEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The entry of the AC switch state on this POE power."
 | 
						|
      INDEX { hh3cPOEACSwitchStateIndex }
 | 
						|
      ::= { hh3cPOEACSwitchStateTable 1 }
 | 
						|
 | 
						|
Hh3cPOEACSwitchStateEntry ::=
 | 
						|
      SEQUENCE {
 | 
						|
                hh3cPOEACSwitchStateIndex
 | 
						|
                        Integer32,
 | 
						|
                hh3cPOEACSwitchState
 | 
						|
                        SwitchState
 | 
						|
               }
 | 
						|
 | 
						|
hh3cPOEACSwitchStateIndex OBJECT-TYPE
 | 
						|
      SYNTAX Integer32 (1..2147483647)
 | 
						|
      MAX-ACCESS accessible-for-notify
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The index of the AC switch state on this POE power.
 | 
						|
             The range of this node is from 1 to hh3cPOEACSwitchStateModuleNum."
 | 
						|
      ::= { hh3cPOEACSwitchStateEntry 1 }
 | 
						|
 | 
						|
hh3cPOEACSwitchState OBJECT-TYPE
 | 
						|
      SYNTAX SwitchState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The AC switch state on this POE power.
 | 
						|
             The value of this node will be one of the following values:
 | 
						|
                                 on             (1),
 | 
						|
                                 off            (2),
 | 
						|
                                 highVoltInput  (3),
 | 
						|
                                 lowVoltInput   (4)"
 | 
						|
      ::= { hh3cPOEACSwitchStateEntry 2 }
 | 
						|
 | 
						|
hh3cPOEInCurStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 6 }
 | 
						|
 | 
						|
hh3cPOEInCurStateModuleNum OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The DC input current state of the module on this POE power.
 | 
						|
             It is the maximum of the hh3cPOESwitchStateVolExIndex."
 | 
						|
      ::= { hh3cPOEInCurStateObjects 1 }
 | 
						|
 | 
						|
hh3cPOEInCurAState OBJECT-TYPE
 | 
						|
      SYNTAX ACAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The current A state in the DC input on this POE power.
 | 
						|
                                 normal     (1),
 | 
						|
                                 underLimit (2),
 | 
						|
                                 aboveLimit (3),
 | 
						|
                                 lackPhrase (4),
 | 
						|
                                 fuseBroken (5),
 | 
						|
                                 switchOff  (6),
 | 
						|
                                 otherError (7)."
 | 
						|
      ::= { hh3cPOEInCurStateObjects 2 }
 | 
						|
 | 
						|
hh3cPOEInCurBState OBJECT-TYPE
 | 
						|
      SYNTAX ACAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The current B state in the DC input on this POE power.
 | 
						|
             The value of this node will be one of the following values:
 | 
						|
                                 normal     (1),
 | 
						|
                                 underLimit (2),
 | 
						|
                                 aboveLimit (3),
 | 
						|
                                 lackPhrase (4),
 | 
						|
                                 fuseBroken (5),
 | 
						|
                                 switchOff  (6),
 | 
						|
                                 otherError (7)."
 | 
						|
      ::= { hh3cPOEInCurStateObjects 3 }
 | 
						|
 | 
						|
hh3cPOEInCurCState OBJECT-TYPE
 | 
						|
      SYNTAX ACAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The current C state in the DC input on this POE power.
 | 
						|
             The value of this node will be one of the following values:
 | 
						|
                                 normal     (1),
 | 
						|
                                 underLimit (2),
 | 
						|
                                 aboveLimit (3),
 | 
						|
                                 lackPhrase (4),
 | 
						|
                                 fuseBroken (5),
 | 
						|
                                 switchOff  (6),
 | 
						|
                                 otherError (7)."
 | 
						|
      ::= { hh3cPOEInCurStateObjects 4 }
 | 
						|
 | 
						|
hh3cPOESwitchStateVolExTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cPOESwitchStateVolExEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "All alarm status of the VOL status.
 | 
						|
             The value of this node will be one of the following values:
 | 
						|
                                 normal     (1),
 | 
						|
                                 underLimit (2),
 | 
						|
                                 aboveLimit (3),
 | 
						|
                                 lackPhrase (4),
 | 
						|
                                 fuseBroken (5),
 | 
						|
                                 switchOff  (6),
 | 
						|
                                 otherError (7)."
 | 
						|
      ::= { hh3cPOEInCurStateObjects 5 }
 | 
						|
 | 
						|
hh3cPOESwitchStateVolExEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPOESwitchStateVolExEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The hh3cPOESwitchStateVolExIndex will match the number of the VOL status."
 | 
						|
      INDEX { hh3cPOESwitchStateVolExIndex }
 | 
						|
      ::= { hh3cPOESwitchStateVolExTable 1 }
 | 
						|
 | 
						|
Hh3cPOESwitchStateVolExEntry ::=
 | 
						|
      SEQUENCE {
 | 
						|
               hh3cPOESwitchStateVolExIndex
 | 
						|
                       Integer32,
 | 
						|
               hh3cPOESwitchStateInVolAB
 | 
						|
                       ACAlarmState,
 | 
						|
               hh3cPOESwitchStateInVolBC
 | 
						|
                       ACAlarmState,
 | 
						|
               hh3cPOESwitchStateInVolCA
 | 
						|
                       ACAlarmState
 | 
						|
               }
 | 
						|
 | 
						|
hh3cPOESwitchStateVolExIndex OBJECT-TYPE
 | 
						|
      SYNTAX Integer32 (1..2147483647)
 | 
						|
      MAX-ACCESS accessible-for-notify
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object species the index of the VOL status.
 | 
						|
             The range of this node is from 1 to hh3cPOEInCurStateModuleNum."
 | 
						|
      ::= { hh3cPOESwitchStateVolExEntry 1 }
 | 
						|
 | 
						|
hh3cPOESwitchStateInVolAB OBJECT-TYPE
 | 
						|
      SYNTAX ACAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the VOL AB alarm in each VOL status.
 | 
						|
             The value of this node will be one of the following values:
 | 
						|
                                 normal     (1),
 | 
						|
                                 underLimit (2),
 | 
						|
                                 aboveLimit (3),
 | 
						|
                                 lackPhrase (4),
 | 
						|
                                 fuseBroken (5),
 | 
						|
                                 switchOff  (6),
 | 
						|
                                 otherError (7)."
 | 
						|
      ::= { hh3cPOESwitchStateVolExEntry 2 }
 | 
						|
 | 
						|
hh3cPOESwitchStateInVolBC OBJECT-TYPE
 | 
						|
      SYNTAX ACAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the VOL BC alarm in each VOL status.
 | 
						|
             The value of this node will be one of the following values:
 | 
						|
                                 normal     (1),
 | 
						|
                                 underLimit (2),
 | 
						|
                                 aboveLimit (3),
 | 
						|
                                 lackPhrase (4),
 | 
						|
                                 fuseBroken (5),
 | 
						|
                                 switchOff  (6),
 | 
						|
                                 otherError (7)."
 | 
						|
      ::= { hh3cPOESwitchStateVolExEntry 3 }
 | 
						|
 | 
						|
hh3cPOESwitchStateInVolCA OBJECT-TYPE
 | 
						|
      SYNTAX ACAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the VOL CA alarm in each VOL status.
 | 
						|
             The value of this node will be one of the following values:
 | 
						|
                                 normal     (1),
 | 
						|
                                 underLimit (2),
 | 
						|
                                 aboveLimit (3),
 | 
						|
                                 lackPhrase (4),
 | 
						|
                                 fuseBroken (5),
 | 
						|
                                 switchOff  (6),
 | 
						|
                                 otherError (7)."
 | 
						|
      ::= { hh3cPOESwitchStateVolExEntry 4 }
 | 
						|
 | 
						|
hh3cPOEAlarmStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 7 }
 | 
						|
 | 
						|
hh3cPOEAlarmStateModuleNum OBJECT-TYPE
 | 
						|
      SYNTAX Integer32
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The object specifies the number of the power modules in alarm state."
 | 
						|
      ::= { hh3cPOEAlarmStateObjects 1 }
 | 
						|
 | 
						|
hh3cPOEAlarmStateInfoTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF Hh3cPOEAlarmStateInfoEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "All alarm states in the POE power modules."
 | 
						|
      ::= { hh3cPOEAlarmStateObjects 2 }
 | 
						|
 | 
						|
hh3cPOEAlarmStateInfoEntry OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPOEAlarmStateInfoEntry
 | 
						|
      MAX-ACCESS not-accessible
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The hh3cPOEAlarmModuleInfoIndex will match the number
 | 
						|
             of the power module."
 | 
						|
INDEX { hh3cPOEAlarmModuleInfoIndex }
 | 
						|
      ::= { hh3cPOEAlarmStateInfoTable 1 }
 | 
						|
 | 
						|
Hh3cPOEAlarmStateInfoEntry ::=
 | 
						|
      SEQUENCE {
 | 
						|
               hh3cPOEAlarmModuleInfoIndex
 | 
						|
                       Integer32,
 | 
						|
               hh3cPOEModuleDisconnect
 | 
						|
                       ModuleAlarmState,
 | 
						|
               hh3cPOEModuleInputError
 | 
						|
                       ModuleAlarmState,
 | 
						|
               hh3cPOEModuleOutputError
 | 
						|
                       ModuleAlarmState,
 | 
						|
               hh3cPOEModuleOverVoltage
 | 
						|
                       ModuleAlarmState,
 | 
						|
               hh3cPOEModuleOverTemp
 | 
						|
                       ModuleAlarmState,
 | 
						|
               hh3cPOEModuleFanError
 | 
						|
                       ModuleAlarmState,
 | 
						|
               hh3cPOEModuleShutdown
 | 
						|
                       ModuleAlarmState,
 | 
						|
               hh3cPOEModuleCurRestricted
 | 
						|
                       ModuleAlarmState
 | 
						|
               }
 | 
						|
 | 
						|
hh3cPOEAlarmModuleInfoIndex OBJECT-TYPE
 | 
						|
      SYNTAX Integer32 (1..2147483647)
 | 
						|
      MAX-ACCESS accessible-for-notify
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The index specifies the index of the Hh3cPOEAlarmStateInfoEntry table.
 | 
						|
             The range of this node is from 1 to hh3cPOEAlarmStateModuleNum."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 1 }
 | 
						|
 | 
						|
hh3cPOEModuleDisconnect OBJECT-TYPE
 | 
						|
      SYNTAX ModuleAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The node specifies the alarm state:
 | 
						|
             The module does not link.
 | 
						|
             The value of this node is one of the following values:
 | 
						|
                              normal (1),
 | 
						|
                              alarm  (2)."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 2 }
 | 
						|
 | 
						|
hh3cPOEModuleInputError OBJECT-TYPE
 | 
						|
      SYNTAX ModuleAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The node specifies the alarm state:
 | 
						|
                                 Input error.
 | 
						|
             The value of this node is one of the following values:
 | 
						|
                                 normal (1),
 | 
						|
                                 alarm  (2)."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 3 }
 | 
						|
 | 
						|
hh3cPOEModuleOutputError OBJECT-TYPE
 | 
						|
      SYNTAX ModuleAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The node specifies the alarm state:
 | 
						|
                                 Output error.
 | 
						|
             The value of this node is one of the following values:
 | 
						|
                                 normal (1),
 | 
						|
                                 alarm  (2)."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 4 }
 | 
						|
 | 
						|
hh3cPOEModuleOverVoltage OBJECT-TYPE
 | 
						|
      SYNTAX ModuleAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The node specifies the alarm state:
 | 
						|
                                 The voltage is too high.
 | 
						|
             The value of this node is one of the following values:
 | 
						|
                                 normal (1),
 | 
						|
                                 alarm  (2)."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 5 }
 | 
						|
 | 
						|
hh3cPOEModuleOverTemp OBJECT-TYPE
 | 
						|
      SYNTAX ModuleAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The node specifies the alarm state:
 | 
						|
                                 The temperature is too high.
 | 
						|
             The value of this node is one of the following values:
 | 
						|
                                 normal (1),
 | 
						|
                                 alarm  (2)."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 6 }
 | 
						|
 | 
						|
hh3cPOEModuleFanError OBJECT-TYPE
 | 
						|
      SYNTAX ModuleAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The node specifies the alarm state:
 | 
						|
                                 The fan error.
 | 
						|
             The value of this node is one of the following values:
 | 
						|
                                 normal (1),
 | 
						|
                                 alarm  (2)."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 7 }
 | 
						|
 | 
						|
hh3cPOEModuleShutdown OBJECT-TYPE
 | 
						|
      SYNTAX ModuleAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The node specifies the alarm state:
 | 
						|
                                 The module is shutdown.
 | 
						|
             The value of this node is one of the following values:
 | 
						|
                                 normal (1),
 | 
						|
                                 alarm  (2)."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 8 }
 | 
						|
 | 
						|
hh3cPOEModuleCurRestricted OBJECT-TYPE
 | 
						|
      SYNTAX ModuleAlarmState
 | 
						|
      MAX-ACCESS read-only
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
             "The node specifies the alarm state:
 | 
						|
                                 The module limit the current.
 | 
						|
             The value of this node is one of the following values:
 | 
						|
                                 normal (1),
 | 
						|
                                 alarm  (2)."
 | 
						|
      ::= { hh3cPOEAlarmStateInfoEntry 9 }
 | 
						|
 | 
						|
Hh3cPDDisableState ::= TEXTUAL-CONVENTION
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
           "PD disabled State."
 | 
						|
      SYNTAX INTEGER{
 | 
						|
             unknown(0),
 | 
						|
             overInrush(1),
 | 
						|
             lessMPSCurrent(2),
 | 
						|
             peakPower(3),
 | 
						|
             overVoltage(4),
 | 
						|
             underVoltage(5),
 | 
						|
             overTemperature(6),
 | 
						|
             shortCircuit(7)
 | 
						|
                   }
 | 
						|
 | 
						|
hh3cPseNotification  OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 11 }
 | 
						|
hh3cPseNotificationPrefix OBJECT IDENTIFIER ::= { hh3cPseNotification 0 }
 | 
						|
 | 
						|
    hh3cPsePDDisableNotification NOTIFICATION-TYPE
 | 
						|
      OBJECTS{ hh3cPsePortGroupIndex, hh3cPsePortIndex, hh3cPsePortDisableInfo }
 | 
						|
      STATUS current
 | 
						|
      DESCRIPTION
 | 
						|
            "The PD has been powered off."
 | 
						|
      ::= { hh3cPseNotificationPrefix 1 }
 | 
						|
 | 
						|
hh3cPseNotificationObjects OBJECT IDENTIFIER ::= { hh3cPseNotification 1 }
 | 
						|
 | 
						|
       hh3cPsePortGroupIndex OBJECT-TYPE
 | 
						|
       SYNTAX      Integer32 (1..2147483647)
 | 
						|
       MAX-ACCESS  accessible-for-notify
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "This variable uniquely identifies the group
 | 
						|
            containing the port to which a power Ethernet PSE is
 | 
						|
            connected."
 | 
						|
       ::= { hh3cPseNotificationObjects 1 }
 | 
						|
 | 
						|
     hh3cPsePortIndex OBJECT-TYPE
 | 
						|
       SYNTAX      Integer32 (1..2147483647)
 | 
						|
       MAX-ACCESS  accessible-for-notify
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "This variable uniquely identifies the power Ethernet PSE
 | 
						|
            port within group pethPsePortGroupIndex to which the
 | 
						|
            power Ethernet PSE entry is connected."
 | 
						|
       ::= { hh3cPseNotificationObjects 2 }
 | 
						|
 | 
						|
     hh3cPsePortDisableInfo OBJECT-TYPE
 | 
						|
      SYNTAX Hh3cPDDisableState
 | 
						|
          MAX-ACCESS  accessible-for-notify
 | 
						|
          STATUS      current
 | 
						|
          DESCRIPTION
 | 
						|
              "
 | 
						|
              Reason that caused PSE port power failure.
 | 
						|
              The calue of this node is one of the following values:
 | 
						|
              unknown(0),
 | 
						|
              overInrush(1),
 | 
						|
              lessMPSCurrent(2),
 | 
						|
              peakPower(3),
 | 
						|
              overVoltage(4),
 | 
						|
              underVoltage(5),
 | 
						|
              overTemperature(6),
 | 
						|
              shortCircuit(7).
 | 
						|
              "
 | 
						|
          ::= { hh3cPseNotificationObjects 3 }
 | 
						|
 | 
						|
END
 | 
						|
 |