--MibName=raisecomOpticalMonitorMIB
 | 
						||
-- *****************************************************************
 | 
						||
-- RAISECOM-OPTICAL-MONITOR-MIB.my
 | 
						||
--
 | 
						||
-- May 2006, chenyu
 | 
						||
--
 | 
						||
-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd.
 | 
						||
-- All rights reserved.
 | 
						||
-- *****************************************************************
 | 
						||
 | 
						||
 | 
						||
RAISECOM-OPTICAL-MONITOR-MIB DEFINITIONS ::= BEGIN
 | 
						||
 | 
						||
IMPORTS
 | 
						||
    Integer32, Unsigned32,
 | 
						||
    MODULE-IDENTITY,
 | 
						||
    NOTIFICATION-TYPE,
 | 
						||
    OBJECT-TYPE,
 | 
						||
    TimeTicks                       	FROM SNMPv2-SMI
 | 
						||
    TEXTUAL-CONVENTION                  FROM SNMPv2-TC
 | 
						||
    MODULE-COMPLIANCE,
 | 
						||
    NOTIFICATION-GROUP,
 | 
						||
    OBJECT-GROUP                        FROM SNMPv2-CONF
 | 
						||
    ifIndex                             FROM IF-MIB
 | 
						||
    EnableVar        					FROM SWITCH-TC
 | 
						||
    raisecomAgent                       FROM RAISECOM-BASE-MIB;
 | 
						||
 | 
						||
raisecomOpticalMonitorMIB MODULE-IDENTITY
 | 
						||
    LAST-UPDATED   "200606060000Z"
 | 
						||
    ORGANIZATION   "Raisecom, Inc."
 | 
						||
    CONTACT-INFO
 | 
						||
                "       Raise Systems
 | 
						||
 | 
						||
                Postal: Beijing,
 | 
						||
                        China
 | 
						||
 | 
						||
                   Tel: 86-010-82884499
 | 
						||
 | 
						||
                E-mail: chenyu@raisecom.com"
 | 
						||
    DESCRIPTION
 | 
						||
        "This MIB module defines objects to monitor optical
 | 
						||
        characteristics on the optical interfaces in a network element. "
 | 
						||
        REVISION   "200606060000Z"
 | 
						||
        DESCRIPTION
 | 
						||
            "The initial revision of this MIB."
 | 
						||
        ::={ raisecomAgent 9 }
 | 
						||
 | 
						||
 | 
						||
-- Textual Conventions
 | 
						||
 | 
						||
OpticalParameterType ::= TEXTUAL-CONVENTION
 | 
						||
    STATUS    current
 | 
						||
    DESCRIPTION
 | 
						||
        "This value indicates the optical parameter that is
 | 
						||
        being monitored. Valid values are -
 | 
						||
 | 
						||
        temperature(1)
 | 
						||
        supplyVoltage(2)
 | 
						||
        biasCurrent(3)
 | 
						||
        txOutputPower(4)
 | 
						||
        receivedPower(5)               "
 | 
						||
    SYNTAX    INTEGER {
 | 
						||
 			       		temperature(1),
 | 
						||
    			    	supplyVoltage(2),
 | 
						||
      				  	biasCurrent(3),
 | 
						||
        				txOutputPower(4),
 | 
						||
        				receivedPower(5)
 | 
						||
              }
 | 
						||
 | 
						||
 | 
						||
OpticalParameterValue ::= TEXTUAL-CONVENTION
 | 
						||
    STATUS    current
 | 
						||
    DESCRIPTION
 | 
						||
        "The value of the optical parameter that is being monitored.
 | 
						||
 | 
						||
        The range of values varies depending on the type of optical
 | 
						||
        parameter being monitored, as identified by a corresponding
 | 
						||
        object with syntax OpticalParameterType.
 | 
						||
 | 
						||
        When the optical parameter being monitored is 'temperature',
 | 
						||
        the supported range is from -32768 to 32768, in units of
 | 
						||
        1/256 degrees centigrade.
 | 
						||
        Example: A value of 6016 represents a temperature reading of
 | 
						||
        23.5 degrees C.
 | 
						||
 | 
						||
        When the optical parameter being monitored is 'supplyVoltage',
 | 
						||
        the supported range is from 0 to 65535, in units of 1/10 millivolts.
 | 
						||
        Example: A value of 55000 represents a supplyVoltage reading of
 | 
						||
        5.5 V.
 | 
						||
 | 
						||
        When the optical parameter being monitored is 'biasCurrent',
 | 
						||
        the supported range is from 0 to 65535, in units of 1/500
 | 
						||
        microamperes.
 | 
						||
        Example: A value of 500 represents a bias current reading of
 | 
						||
        1 microamperes.
 | 
						||
 | 
						||
        When the optical parameter being monitored is 'txOutputPower',
 | 
						||
        the supported range is from 0 to 65535, in units of 1/10000 mW ..and express in units of dBm<42><6D>
 | 
						||
        Example: A value of 60000 represents a txOutputPower reading of 7.78 dBm.
 | 
						||
 | 
						||
        When the optical parameter being monitored is 'receivedPower',
 | 
						||
        the supported range is from 0 to 65535, in units of 1/10000 mW ..and express in units of dBm<42><6D>
 | 
						||
        Example: A value of 60000 represents a receivedPower reading of 7.78 dBm.        "
 | 
						||
    SYNTAX    Integer32 (-1000000..65535 )
 | 
						||
 | 
						||
OpticalPMPeriod ::= TEXTUAL-CONVENTION
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This value indicates the time period over which performance
 | 
						||
        monitoring data has been collected."
 | 
						||
    SYNTAX      INTEGER {
 | 
						||
                    fifteenMin(1),
 | 
						||
                    twentyFourHour(2)
 | 
						||
                }
 | 
						||
 | 
						||
-- MIB Object Definitions
 | 
						||
 | 
						||
raisecomOpticalMonitorMIBObjects        OBJECT IDENTIFIER ::=
 | 
						||
                                        {raisecomOpticalMonitorMIB 1 }
 | 
						||
 | 
						||
-- groups in this MIB module
 | 
						||
 | 
						||
raisecomOpticalMonGroup                OBJECT IDENTIFIER ::=
 | 
						||
                                        {raisecomOpticalMonitorMIBObjects 1 }
 | 
						||
 | 
						||
raisecomOpticalPMGroup                 OBJECT IDENTIFIER ::=
 | 
						||
                                        {raisecomOpticalMonitorMIBObjects 2 }
 | 
						||
 | 
						||
-- raisecomTranceiverInfoTable
 | 
						||
 | 
						||
raisecomTranceiverInfoTable OBJECT-TYPE
 | 
						||
        SYNTAX SEQUENCE OF RaisecomTranceiverInfoEntry
 | 
						||
        MAX-ACCESS not-accessible
 | 
						||
        STATUS current
 | 
						||
        DESCRIPTION
 | 
						||
            "Trancetver information Table."
 | 
						||
        ::= { raisecomOpticalMonitorMIBObjects 4 }
 | 
						||
 | 
						||
raisecomTranceiverInfoEntry OBJECT-TYPE
 | 
						||
    SYNTAX      RaisecomTranceiverInfoEntry
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "An entry in the raisecomSfpAccessA0Table."
 | 
						||
    INDEX        { ifIndex }
 | 
						||
    ::={ raisecomTranceiverInfoTable 1 }
 | 
						||
 | 
						||
 | 
						||
RaisecomTranceiverInfoEntry ::= SEQUENCE {
 | 
						||
	raisecomTranceiverType        OCTET STRING,
 | 
						||
	raisecomTranceiverConnectorType       OCTET STRING,
 | 
						||
	raisecomTranceiverWavelength  Integer32,
 | 
						||
	raisecomTranceiverVendorName  OCTET STRING,
 | 
						||
	raisecomTranceiverVendorPN    OCTET STRING,
 | 
						||
	raisecomTranceiverVendorSN    OCTET STRING,
 | 
						||
	raisecomTransceiverFiberType INTEGER,
 | 
						||
	raisecomTransceiverTransferDistance  Integer32
 | 
						||
}
 | 
						||
 | 
						||
raisecomTranceiverType OBJECT-TYPE
 | 
						||
		SYNTAX	OCTET STRING
 | 
						||
		ACCESS	read-only
 | 
						||
		STATUS	current
 | 
						||
		DESCRIPTION
 | 
						||
			"Type of the interface, such as 1000_BASE_SX_SFP"
 | 
						||
		::= { raisecomTranceiverInfoEntry 1 }
 | 
						||
 | 
						||
raisecomTranceiverConnectorType OBJECT-TYPE
 | 
						||
		SYNTAX	OCTET STRING
 | 
						||
		ACCESS	read-only
 | 
						||
		STATUS	current
 | 
						||
		DESCRIPTION
 | 
						||
			"ConnectorType of the interface, such as SC/LC"
 | 
						||
		::= { raisecomTranceiverInfoEntry 2 }
 | 
						||
 | 
						||
raisecomTranceiverWavelength OBJECT-TYPE
 | 
						||
		SYNTAX	Integer32
 | 
						||
		ACCESS	read-only
 | 
						||
		STATUS	current
 | 
						||
		DESCRIPTION
 | 
						||
			"Wavelength of the interface, measured in nm."
 | 
						||
		::= { raisecomTranceiverInfoEntry 3 }
 | 
						||
 | 
						||
raisecomTranceiverVendorName OBJECT-TYPE
 | 
						||
		SYNTAX	OCTET STRING
 | 
						||
		ACCESS	read-only
 | 
						||
		STATUS	current
 | 
						||
		DESCRIPTION
 | 
						||
			"Vendor name of the interface."
 | 
						||
		::= { raisecomTranceiverInfoEntry 4 }
 | 
						||
 | 
						||
raisecomTranceiverVendorPN OBJECT-TYPE
 | 
						||
		SYNTAX	OCTET STRING
 | 
						||
		ACCESS	read-only
 | 
						||
		STATUS	current
 | 
						||
		DESCRIPTION
 | 
						||
			"Vendor part number of the interface."
 | 
						||
		::= { raisecomTranceiverInfoEntry 5 }
 | 
						||
 | 
						||
raisecomTranceiverVendorSN OBJECT-TYPE
 | 
						||
		SYNTAX	OCTET STRING
 | 
						||
		ACCESS	read-only
 | 
						||
		STATUS	current
 | 
						||
		DESCRIPTION
 | 
						||
			"Vendor serial number of the interface."
 | 
						||
		::= { raisecomTranceiverInfoEntry 6 }
 | 
						||
 | 
						||
raisecomTransceiverFiberType OBJECT-TYPE
 | 
						||
		SYNTAX INTEGER
 | 
						||
       {
 | 
						||
          single-mode(1),
 | 
						||
          multi-mode(2),
 | 
						||
          none(3)
 | 
						||
        }
 | 
						||
		ACCESS	read-only
 | 
						||
		STATUS	current
 | 
						||
		DESCRIPTION
 | 
						||
			"Types of the fiber,
 | 
						||
            single_mode, multi_mode, none."
 | 
						||
		::= { raisecomTranceiverInfoEntry 7 }
 | 
						||
 | 
						||
raisecomTransceiverTransferDistance OBJECT-TYPE
 | 
						||
		SYNTAX	Integer32
 | 
						||
		ACCESS	read-only
 | 
						||
		STATUS	current
 | 
						||
		DESCRIPTION
 | 
						||
			"The max distance which the interface could transmit,
 | 
						||
            measured in meter."
 | 
						||
		::= { raisecomTranceiverInfoEntry 8 }
 | 
						||
 | 
						||
 | 
						||
 | 
						||
 | 
						||
-- raisecomOpticalMonTable
 | 
						||
 | 
						||
raisecomOpticalMonTable OBJECT-TYPE
 | 
						||
    SYNTAX      SEQUENCE OF RaisecomOpticalMonEntry
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This table provides objects to monitor optical
 | 
						||
        parameters in a network element. "
 | 
						||
    ::={ raisecomOpticalMonGroup 1 }
 | 
						||
 | 
						||
raisecomOpticalMonEntry OBJECT-TYPE
 | 
						||
    SYNTAX      RaisecomOpticalMonEntry
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "An entry in the raisecomOpticalMonTable provides objects to
 | 
						||
        monitor an optical parameter at an optical interface.
 | 
						||
        "
 | 
						||
    INDEX        { ifIndex, raisecomOpticalMonParameterType }
 | 
						||
    ::={ raisecomOpticalMonTable 1 }
 | 
						||
 | 
						||
 | 
						||
RaisecomOpticalMonEntry ::= SEQUENCE {
 | 
						||
    raisecomOpticalMonParameterType            OpticalParameterType,
 | 
						||
    raisecomOpticalParameterValue              OpticalParameterValue,
 | 
						||
    raisecomOpticalParamHighAlarmThresh        OpticalParameterValue,
 | 
						||
    raisecomOpticalParamHighWarningThresh      OpticalParameterValue,
 | 
						||
    raisecomOpticalParamLowAlarmThresh         OpticalParameterValue,
 | 
						||
    raisecomOpticalParamLowWarningThresh       OpticalParameterValue,
 | 
						||
    raisecomOpticalParamAlarmStatus            INTEGER,
 | 
						||
    raisecomOpticalParamAlarmLastValue         OpticalParameterValue,
 | 
						||
    raisecomOpticalParamAlarmLastChange        TimeTicks,
 | 
						||
    raisecomOpticalMon15MinValidIntervals      Unsigned32,
 | 
						||
    raisecomOpticalMon24HrValidIntervals       Unsigned32,
 | 
						||
    raisecomOpticalMonValidStatus        INTEGER
 | 
						||
}
 | 
						||
 | 
						||
raisecomOpticalMonParameterType OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterType
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object specifies the optical parameter that is being
 | 
						||
        monitored in this entry."
 | 
						||
    ::={ raisecomOpticalMonEntry 1 }
 | 
						||
 | 
						||
raisecomOpticalParameterValue OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the value measured for the particular
 | 
						||
        optical parameter specified by the raisecomOpticalMonParameterType
 | 
						||
        object."
 | 
						||
    ::={ raisecomOpticalMonEntry 2 }
 | 
						||
 | 
						||
raisecomOpticalParamHighAlarmThresh OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the high alarm threshold on the
 | 
						||
        optical parameter being monitored.
 | 
						||
 | 
						||
        An alarm condition will be raised if the value given by
 | 
						||
        raisecomOpticalParameterValue goes from below the value of
 | 
						||
        this object to above the value of this object, or if
 | 
						||
        the initial value of raisecomOpticalParameterValue exceeds the value
 | 
						||
        of this object. This alarm will be indicated in the
 | 
						||
        raisecomOpticalParamAlarmStatus object."
 | 
						||
    ::={ raisecomOpticalMonEntry 3 }
 | 
						||
 | 
						||
raisecomOpticalParamHighWarningThresh OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object is used to set a high warning threshold on
 | 
						||
        the optical parameter being monitored.
 | 
						||
 | 
						||
        A threshold crossing condition will be indicated if the value
 | 
						||
        given by raisecomOpticalParameterValue goes from below the value
 | 
						||
        of this object to above the value of this
 | 
						||
        object, or if the initial value of raisecomOpticalParameterValue
 | 
						||
        exceeds the value of this object. This alarm will be indicated in the
 | 
						||
        raisecomOpticalParamAlarmStatus object.
 | 
						||
        "
 | 
						||
    ::={ raisecomOpticalMonEntry 4 }
 | 
						||
 | 
						||
raisecomOpticalParamLowAlarmThresh OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object is used to set a low alarm threshold on the
 | 
						||
        optical parameter being monitored.
 | 
						||
 | 
						||
        An alarm condition will be raised if the value given by
 | 
						||
        raisecomOpticalParameterValue goes from above the value of
 | 
						||
        this object to below the value of this object, or if
 | 
						||
        the initial value of raisecomOpticalParameterValue is lower than the
 | 
						||
        value of this object. This alarm
 | 
						||
        will be indicated in the raisecomOpticalParamAlarmStatus object .."
 | 
						||
    ::={ raisecomOpticalMonEntry 5 }
 | 
						||
 | 
						||
raisecomOpticalParamLowWarningThresh OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object is used to set a low warning threshold on
 | 
						||
        the optical parameter being monitored.
 | 
						||
 | 
						||
        A threshold crossing condition will be indicated if the value
 | 
						||
        given by raisecomOpticalParameterValue goes from above the value
 | 
						||
        of this object to below the value of this
 | 
						||
        object, or if the initial value of raisecomOpticalParameterValue
 | 
						||
        object is lower than the value of this object. For
 | 
						||
        network elements in the status
 | 
						||
        indications, this threshold violation will be indicated in the
 | 
						||
        raisecomOpticalParamAlarmStatus object ."
 | 
						||
    ::={ raisecomOpticalMonEntry 6 }
 | 
						||
 | 
						||
raisecomOpticalParamAlarmStatus OBJECT-TYPE
 | 
						||
    SYNTAX      INTEGER {
 | 
						||
    		          none(0),
 | 
						||
                          high-alarm-threshold(1),
 | 
						||
                          high-warning-threshold(2),
 | 
						||
                          low-alarm-threshold(3),
 | 
						||
                          low-warning-threshold(4)
 | 
						||
                      }
 | 
						||
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object is used to indicate the current status of
 | 
						||
        the thresholds for the monitored optical parameter
 | 
						||
        on the interface.
 | 
						||
 | 
						||
           If a threshold is currently being exceeded on the
 | 
						||
           interface, the object  will be set. Otherwise,
 | 
						||
           the object will be set to 0."
 | 
						||
    ::={ raisecomOpticalMonEntry 7 }
 | 
						||
 | 
						||
raisecomOpticalParamAlarmLastValue OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object indicates the optical parameter value at the last time
 | 
						||
        a threshold related to a particular optical parameter was
 | 
						||
        exceeded on the interface.
 | 
						||
        If no threshold value is currently being
 | 
						||
        exceeded, then the value '-1000000' is returned."
 | 
						||
    ::={ raisecomOpticalMonEntry 8 }
 | 
						||
 | 
						||
raisecomOpticalParamAlarmLastChange OBJECT-TYPE
 | 
						||
    SYNTAX      TimeTicks
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object specifies the value of sysUpTime at the last time
 | 
						||
        a threshold related to a particular optical parameter was
 | 
						||
        exceeded on the interface."
 | 
						||
    ::={ raisecomOpticalMonEntry 9 }
 | 
						||
 | 
						||
raisecomOpticalMon15MinValidIntervals OBJECT-TYPE
 | 
						||
    SYNTAX      Unsigned32 (0..96)
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the number of previous 15 minute
 | 
						||
        intervals for which valid performance monitoring data
 | 
						||
        has been stored on the interface.
 | 
						||
 | 
						||
        The value of this object will be n (where n is the maximum
 | 
						||
        number of 15 minute intervals supported at this interface),
 | 
						||
        unless the measurement was (re-)started within the last
 | 
						||
        (nx15) minutes, in which case the value will be the
 | 
						||
        number of previous 15 minute intervals for which the agent
 | 
						||
        has some data."
 | 
						||
    ::={ raisecomOpticalMonEntry 10 }
 | 
						||
 | 
						||
raisecomOpticalMon24HrValidIntervals OBJECT-TYPE
 | 
						||
    SYNTAX      Unsigned32 (0..1)
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the number of previous 24 hour
 | 
						||
        intervals for which valid performance monitoring data
 | 
						||
        has been stored on the interface.
 | 
						||
 | 
						||
        The value of this object will be 0 if the measurement
 | 
						||
        was (re-)started within the last 24 hours, or 1 otherwise."
 | 
						||
    ::={ raisecomOpticalMonEntry 11 }
 | 
						||
 | 
						||
raisecomOpticalMonValidStatus OBJECT-TYPE
 | 
						||
    SYNTAX      INTEGER {
 | 
						||
                    valid(1),
 | 
						||
                    invalid(2)
 | 
						||
                }
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object indicates the parameter row is valid or not."
 | 
						||
    ::={ raisecomOpticalMonEntry 12 }
 | 
						||
 | 
						||
-- Notification related objects
 | 
						||
 | 
						||
raisecomOpticalNotifyEnable OBJECT-TYPE
 | 
						||
    SYNTAX      EnableVar
 | 
						||
    MAX-ACCESS  read-write
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object specifies the generation of raisecomOpticalMonParameterStatus notifications.
 | 
						||
        "
 | 
						||
    DEFVAL { enable}
 | 
						||
    ::={ raisecomOpticalMonGroup 2 }
 | 
						||
 | 
						||
raisecomOpticalDigitalDiagnoticEnable OBJECT-TYPE
 | 
						||
    SYNTAX      EnableVar
 | 
						||
    MAX-ACCESS  read-write
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "Enable or disable digitaldiagnotic on the switch."
 | 
						||
    DEFVAL { disable}
 | 
						||
    ::={ raisecomOpticalMonGroup 3 }
 | 
						||
 | 
						||
-- raisecomOpticalPMCurrent Table
 | 
						||
 | 
						||
raisecomOpticalPMCurrentTable OBJECT-TYPE
 | 
						||
    SYNTAX      SEQUENCE OF RaisecomOpticalPMCurrentEntry
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This table contains performance monitoring data for the
 | 
						||
        various optical parameters, collected over the current 15
 | 
						||
        minute or the current 24 hour interval."
 | 
						||
    ::={ raisecomOpticalPMGroup 1 }
 | 
						||
 | 
						||
raisecomOpticalPMCurrentEntry OBJECT-TYPE
 | 
						||
    SYNTAX      RaisecomOpticalPMCurrentEntry
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "An entry in the raisecomOpticalPMCurrentTable. It contains
 | 
						||
        performance monitoring data for a monitored optical
 | 
						||
        parameter at an interface, collected over the current 15
 | 
						||
        minute or the current 24 hour interval.
 | 
						||
        "
 | 
						||
    INDEX       { ifIndex,
 | 
						||
                  raisecomOpticalPMCurrentPeriod,
 | 
						||
				  raisecomOpticalPMCurrentParamType }
 | 
						||
    ::={ raisecomOpticalPMCurrentTable 1 }
 | 
						||
 | 
						||
RaisecomOpticalPMCurrentEntry ::= SEQUENCE {
 | 
						||
    raisecomOpticalPMCurrentPeriod             OpticalPMPeriod,
 | 
						||
    raisecomOpticalPMCurrentParamType          OpticalParameterType,
 | 
						||
    raisecomOpticalPMCurrentMaxParam           OpticalParameterValue,
 | 
						||
    raisecomOpticalPMCurrentMinParam           OpticalParameterValue,
 | 
						||
    raisecomOpticalPMCurrentMeanParam          OpticalParameterValue
 | 
						||
}
 | 
						||
 | 
						||
raisecomOpticalPMCurrentPeriod OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalPMPeriod
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object indicates whether the optical parameter values
 | 
						||
        given in this entry are collected over the current 15 minute or
 | 
						||
        the current 24 hour interval."
 | 
						||
    ::={ raisecomOpticalPMCurrentEntry 1 }
 | 
						||
 | 
						||
raisecomOpticalPMCurrentParamType OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterType
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object specifies the optical parameter that is being
 | 
						||
        monitored, in this entry."
 | 
						||
    ::={ raisecomOpticalPMCurrentEntry 2 }
 | 
						||
 | 
						||
raisecomOpticalPMCurrentMaxParam OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the maximum value measured for the monitored
 | 
						||
        optical parameter, in the current 15 minute or the current
 | 
						||
        24 hour interval."
 | 
						||
    ::={ raisecomOpticalPMCurrentEntry 3 }
 | 
						||
 | 
						||
raisecomOpticalPMCurrentMinParam OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the minimum value measured for the monitored
 | 
						||
        optical parameter, in the current 15 minute or the current
 | 
						||
        24 hour interval."
 | 
						||
    ::={ raisecomOpticalPMCurrentEntry 4 }
 | 
						||
 | 
						||
raisecomOpticalPMCurrentMeanParam OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the average value of the monitored
 | 
						||
        optical parameter, in the current 15 minute or the current
 | 
						||
        24 hour interval."
 | 
						||
    ::={ raisecomOpticalPMCurrentEntry 5 }
 | 
						||
 | 
						||
-- raisecomOpticalPMInterval Table
 | 
						||
 | 
						||
raisecomOpticalPMIntervalTable OBJECT-TYPE
 | 
						||
    SYNTAX      SEQUENCE OF RaisecomOpticalPMIntervalEntry
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This table stores performance monitoring data for the
 | 
						||
        various optical parameters, collected over previous
 | 
						||
        intervals.
 | 
						||
 | 
						||
        This table can have entries for one complete 24 hour
 | 
						||
        interval and up to 96 complete 15 minute
 | 
						||
        intervals. A system is required to store at least
 | 
						||
        4 completed 15 minute intervals. The number of valid
 | 
						||
        15 minute intervals in this table is indicated by the
 | 
						||
        cOpticalMon15MinValidIntervals object and the number of
 | 
						||
        valid 24 hour intervals is indicated by the
 | 
						||
        cOpticalMon24HrValidIntervals object."
 | 
						||
    ::={ raisecomOpticalPMGroup 2 }
 | 
						||
 | 
						||
raisecomOpticalPMIntervalEntry OBJECT-TYPE
 | 
						||
    SYNTAX      RaisecomOpticalPMIntervalEntry
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "An entry in the raisecomOpticalPMIntervalTable. It contains
 | 
						||
        performance monitoring data for an optical parameter,
 | 
						||
        collected over a previous interval.
 | 
						||
        "
 | 
						||
    INDEX      { ifIndex,
 | 
						||
    			raisecomOpticalPMIntervalPeriod,
 | 
						||
                 raisecomOpticalPMIntervalNumber,
 | 
						||
                 raisecomOpticalPMIntervalParamType }
 | 
						||
    ::={ raisecomOpticalPMIntervalTable 1 }
 | 
						||
 | 
						||
RaisecomOpticalPMIntervalEntry ::= SEQUENCE {
 | 
						||
    raisecomOpticalPMIntervalPeriod            OpticalPMPeriod,
 | 
						||
    raisecomOpticalPMIntervalNumber            Integer32,
 | 
						||
    raisecomOpticalPMIntervalParamType         OpticalParameterType,
 | 
						||
    raisecomOpticalPMIntervalMaxParam          OpticalParameterValue,
 | 
						||
    raisecomOpticalPMIntervalMinParam          OpticalParameterValue,
 | 
						||
    raisecomOpticalPMIntervalMeanParam         OpticalParameterValue
 | 
						||
    }
 | 
						||
 | 
						||
raisecomOpticalPMIntervalPeriod OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalPMPeriod
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object indicates whether the optical parameter values,
 | 
						||
        given in this entry, are collected over a period of 15 minutes
 | 
						||
        or 24 hours."
 | 
						||
    ::={ raisecomOpticalPMIntervalEntry 1 }
 | 
						||
 | 
						||
raisecomOpticalPMIntervalNumber OBJECT-TYPE
 | 
						||
    SYNTAX      Integer32 (1..96)
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "A number between 1 and 96, which identifies the
 | 
						||
         interval for which the set of optical parameter values is
 | 
						||
         available. The interval identified by 1 is the most recently
 | 
						||
         completed 15 minute or 24 hour interval, and the interval
 | 
						||
         identified by N is the interval immediately preceding the one
 | 
						||
         identified by N-1."
 | 
						||
    ::={ raisecomOpticalPMIntervalEntry 2 }
 | 
						||
 | 
						||
raisecomOpticalPMIntervalParamType OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterType
 | 
						||
    MAX-ACCESS  not-accessible
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object specifies the optical parameter that is being
 | 
						||
        monitored, in this entry."
 | 
						||
    ::={ raisecomOpticalPMIntervalEntry 3 }
 | 
						||
 | 
						||
raisecomOpticalPMIntervalMaxParam OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the maximum value measured for the optical
 | 
						||
        parameter, in a particular 15 minute or 24 hour interval."
 | 
						||
    ::={ raisecomOpticalPMIntervalEntry 4 }
 | 
						||
 | 
						||
raisecomOpticalPMIntervalMinParam OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the minimum value measured for the optical
 | 
						||
        parameter, in a particular 15 minute or 24 hour interval."
 | 
						||
    ::={ raisecomOpticalPMIntervalEntry 5 }
 | 
						||
 | 
						||
raisecomOpticalPMIntervalMeanParam OBJECT-TYPE
 | 
						||
    SYNTAX      OpticalParameterValue
 | 
						||
    MAX-ACCESS  read-only
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This object gives the average value of the measured optical
 | 
						||
        parameter, in a particular 15 minute or 24 hour interval."
 | 
						||
    ::={ raisecomOpticalPMIntervalEntry 6 }
 | 
						||
 | 
						||
 | 
						||
-- Notifications
 | 
						||
 | 
						||
raisecomOpticalMonitorMIBNotifications OBJECT IDENTIFIER ::=
 | 
						||
                                 { raisecomOpticalMonitorMIB 2 }
 | 
						||
 | 
						||
raisecomOpticalMonParameterStatus NOTIFICATION-TYPE
 | 
						||
    OBJECTS     { raisecomOpticalParameterValue,
 | 
						||
                  raisecomOpticalParamAlarmStatus
 | 
						||
                }
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "This notification is sent when any threshold related to an
 | 
						||
        optical parameter is exceeded on an interface.
 | 
						||
 | 
						||
        This notification may be suppressed under the following
 | 
						||
        conditions:
 | 
						||
        - depending on the value of the raisecomOpticalNotifyEnable object.
 | 
						||
        "
 | 
						||
    ::={ raisecomOpticalMonitorMIBNotifications 1 }
 | 
						||
 | 
						||
-- MIB Conformance Statements
 | 
						||
 | 
						||
raisecomOpticalMonitorMIBConformance  OBJECT IDENTIFIER ::=
 | 
						||
                                { raisecomOpticalMonitorMIB 3 }
 | 
						||
 | 
						||
raisecomOpticalMonitorMIBCompliances  OBJECT IDENTIFIER ::=
 | 
						||
                                { raisecomOpticalMonitorMIBConformance 1 }
 | 
						||
 | 
						||
raisecomOpticalMonitorMIBGroups       OBJECT IDENTIFIER ::=
 | 
						||
                                { raisecomOpticalMonitorMIBConformance 2 }
 | 
						||
 | 
						||
 | 
						||
raisecomOpticalMonitorMIBCompliance MODULE-COMPLIANCE
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "The compliance statement for network elements that
 | 
						||
        monitor optical characteristics and thresholds on the
 | 
						||
        optical interfaces in a network element."
 | 
						||
    MODULE      -- this module
 | 
						||
        MANDATORY-GROUPS { raisecomOpticalMIBMonGroup }
 | 
						||
 | 
						||
    GROUP raisecomOpticalMIBThresholdGroup
 | 
						||
    DESCRIPTION
 | 
						||
        "This group is required for network elements that support
 | 
						||
        thresholds on optical parameters."
 | 
						||
 | 
						||
    GROUP raisecomOpticalMIBPMGroup
 | 
						||
    DESCRIPTION
 | 
						||
        "This group is required for network elements that
 | 
						||
        support collection of optical performance monitoring
 | 
						||
        data for 15 minute or 24 hour intervals."
 | 
						||
 | 
						||
    GROUP raisecomOpticalMIBNotifyEnableGroup
 | 
						||
    DESCRIPTION
 | 
						||
        "This group is required for network elements that
 | 
						||
        support the cOpticalMIBNotifGroup."
 | 
						||
 | 
						||
    GROUP raisecomOpticalMIBNotifGroup
 | 
						||
    DESCRIPTION
 | 
						||
        "This group is required for network elements that
 | 
						||
        generate notifications when a threshold is exceeded or
 | 
						||
        cleared on an interface."
 | 
						||
 | 
						||
    OBJECT     raisecomOpticalParamHighAlarmThresh
 | 
						||
    MIN-ACCESS read-only
 | 
						||
    DESCRIPTION
 | 
						||
        "Write access is not required."
 | 
						||
 | 
						||
    OBJECT     raisecomOpticalParamHighWarningThresh
 | 
						||
    MIN-ACCESS read-only
 | 
						||
    DESCRIPTION
 | 
						||
        "Write access is not required."
 | 
						||
 | 
						||
    OBJECT     raisecomOpticalParamLowAlarmThresh
 | 
						||
    MIN-ACCESS read-only
 | 
						||
    DESCRIPTION
 | 
						||
        "Write access is not required."
 | 
						||
 | 
						||
    OBJECT     raisecomOpticalParamLowWarningThresh
 | 
						||
    MIN-ACCESS read-only
 | 
						||
    DESCRIPTION
 | 
						||
        "Write access is not required."
 | 
						||
 | 
						||
    OBJECT     raisecomOpticalParamHighAlarmSev
 | 
						||
    MIN-ACCESS read-only
 | 
						||
    DESCRIPTION
 | 
						||
        "Write access is not required."
 | 
						||
 | 
						||
    OBJECT     raisecomOpticalParamHighWarningSev
 | 
						||
    MIN-ACCESS read-only
 | 
						||
    DESCRIPTION
 | 
						||
        "Write access is not required."
 | 
						||
 | 
						||
    OBJECT     raisecomOpticalParamLowAlarmSev
 | 
						||
    MIN-ACCESS read-only
 | 
						||
    DESCRIPTION
 | 
						||
        "Write access is not required."
 | 
						||
 | 
						||
    OBJECT     raisecomOpticalParamLowWarningSev
 | 
						||
    MIN-ACCESS read-only
 | 
						||
    DESCRIPTION
 | 
						||
        "Write access is not required."
 | 
						||
 | 
						||
    ::={ raisecomOpticalMonitorMIBCompliances 1 }
 | 
						||
 | 
						||
-- Units of Conformance
 | 
						||
 | 
						||
raisecomOpticalMIBMonGroup OBJECT-GROUP
 | 
						||
    OBJECTS {
 | 
						||
        raisecomOpticalParameterValue
 | 
						||
    }
 | 
						||
    STATUS        current
 | 
						||
    DESCRIPTION
 | 
						||
        "A mandatory object that provides monitoring of optical
 | 
						||
        characteristics."
 | 
						||
    ::={ raisecomOpticalMonitorMIBGroups 1 }
 | 
						||
 | 
						||
raisecomOpticalMIBThresholdGroup OBJECT-GROUP
 | 
						||
    OBJECTS {
 | 
						||
        raisecomOpticalParamHighAlarmThresh,
 | 
						||
        raisecomOpticalParamHighWarningThresh,
 | 
						||
        raisecomOpticalParamLowAlarmThresh,
 | 
						||
        raisecomOpticalParamLowWarningThresh,
 | 
						||
        raisecomOpticalParamAlarmStatus,
 | 
						||
        raisecomOpticalParamAlarmLastValue,
 | 
						||
        raisecomOpticalParamAlarmLastChange
 | 
						||
    }
 | 
						||
    STATUS        current
 | 
						||
    DESCRIPTION
 | 
						||
        "A collection of objects that support thresholds on optical
 | 
						||
        parameters and provide status information when the thresholds
 | 
						||
        are exceeded ."
 | 
						||
    ::={ raisecomOpticalMonitorMIBGroups 2 }
 | 
						||
 | 
						||
raisecomOpticalMIBPMGroup OBJECT-GROUP
 | 
						||
    OBJECTS {
 | 
						||
        raisecomOpticalMon15MinValidIntervals,
 | 
						||
        raisecomOpticalMon24HrValidIntervals,
 | 
						||
        raisecomOpticalPMCurrentMaxParam,
 | 
						||
        raisecomOpticalPMCurrentMinParam,
 | 
						||
        raisecomOpticalPMCurrentMeanParam,
 | 
						||
        raisecomOpticalPMIntervalMaxParam,
 | 
						||
        raisecomOpticalPMIntervalMinParam,
 | 
						||
        raisecomOpticalPMIntervalMeanParam
 | 
						||
    }
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "A collection of objects that provide optical performance
 | 
						||
        monitoring data for 15 minute and 24 hour intervals."
 | 
						||
    ::={ raisecomOpticalMonitorMIBGroups 3 }
 | 
						||
 | 
						||
raisecomOpticalMIBNotifyEnableGroup OBJECT-GROUP
 | 
						||
    OBJECTS {
 | 
						||
        raisecomOpticalNotifyEnable
 | 
						||
    }
 | 
						||
    STATUS        current
 | 
						||
    DESCRIPTION
 | 
						||
        "An object to control the generation of notifications."
 | 
						||
    ::={ raisecomOpticalMonitorMIBGroups 4 }
 | 
						||
 | 
						||
raisecomOpticalMIBNotifGroup NOTIFICATION-GROUP
 | 
						||
    NOTIFICATIONS {
 | 
						||
        raisecomOpticalMonParameterStatus
 | 
						||
    }
 | 
						||
    STATUS      current
 | 
						||
    DESCRIPTION
 | 
						||
        "A notification generated when a threshold on an optical
 | 
						||
         parameter is exceeded or cleared."
 | 
						||
    ::={ raisecomOpticalMonitorMIBGroups 5 }
 | 
						||
 | 
						||
END
 |