238 lines
		
	
	
		
			8.0 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			238 lines
		
	
	
		
			8.0 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
	-- SmartOptics Enterprise Specific TC MIB.
 | 
						|
--
 | 
						|
-- Copyright (c) 2011, SmartOptics
 | 
						|
-- All rights reserved
 | 
						|
--
 | 
						|
 | 
						|
MSERIES-TC DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
    MODULE-IDENTITY
 | 
						|
        FROM SNMPv2-SMI
 | 
						|
    TEXTUAL-CONVENTION
 | 
						|
        FROM SNMPv2-TC
 | 
						|
    mseries
 | 
						|
        FROM MSERIES-MIB;
 | 
						|
 | 
						|
 | 
						|
smartTcMIB     MODULE-IDENTITY
 | 
						|
                LAST-UPDATED    "201402121327Z"
 | 
						|
                ORGANIZATION    "SmartOptics"
 | 
						|
                CONTACT-INFO    "http://www.smartoptics.com"
 | 
						|
                DESCRIPTION
 | 
						|
                                "This is the enterprise specific TC MIB for SmartOptics M-Series"
 | 
						|
                REVISION        "201402121327Z"
 | 
						|
                DESCRIPTION
 | 
						|
                                "Added PortStatus and PortMode."
 | 
						|
 | 
						|
                REVISION        "201310151341Z"
 | 
						|
                DESCRIPTION
 | 
						|
                                "Descriptions updated."
 | 
						|
                REVISION        "201112050000Z"
 | 
						|
                DESCRIPTION
 | 
						|
                                "Initial revision."
 | 
						|
 | 
						|
                ::=  { mseries 5 }
 | 
						|
 | 
						|
--
 | 
						|
-- definitions of the textual convetions
 | 
						|
--
 | 
						|
 | 
						|
AlarmPerceivedSeverity ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Alarm severity as defined in ITU-T X.733."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        cleared (1),
 | 
						|
        indeterminate (2),
 | 
						|
        critical (3),
 | 
						|
        major (4),
 | 
						|
        minor (5),
 | 
						|
        warning (6)
 | 
						|
    }
 | 
						|
 | 
						|
AlarmNotificationType ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "Type of alarm as defined in ITU-T X.733."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        undefined (0),
 | 
						|
        other (1),
 | 
						|
        communicationsAlarm (2),
 | 
						|
        qualityOfServiceAlarm (3),
 | 
						|
        processingErrorAlarm (4),
 | 
						|
        equipmentAlarm (5),
 | 
						|
        environmental (6),
 | 
						|
        integrityViolation (7),
 | 
						|
        operationalViolation (8),
 | 
						|
        physicalViolation(9),
 | 
						|
        securityServiceOrMechanismViloation (10),
 | 
						|
        timeDomainViolation (11)
 | 
						|
        }
 | 
						|
 | 
						|
AlarmProbableCause ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "Alarm probable cause as defined in ITU-T X.733."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        undefined (0),
 | 
						|
        adapterError (1),                       -- Equipment
 | 
						|
        applicationSubsystemFailure (2),        -- Processing
 | 
						|
        bandwidthReduced (3),                   -- Quality of service
 | 
						|
        callEstablishmentError (4),             -- Communications
 | 
						|
        communicationsProtocolError (5),        -- Communications
 | 
						|
        communicationsSubsystemFailure (6),     -- Communications
 | 
						|
        configurationOrCustomizationError (7),  -- Processing
 | 
						|
        congestion (8),                         -- Quality of service
 | 
						|
        corruptData (9),                        -- Processing
 | 
						|
        cpuCyclesLimitExceeded (10),            -- Processing
 | 
						|
        dTEdCEInterfaceError (11),              -- Communications
 | 
						|
        datasetOrModemError (12),               -- Equipment
 | 
						|
        degradedSignal (13),                    -- Communications
 | 
						|
        enclosureDoorOpen (14),                 -- Environmental
 | 
						|
        equipmentMalfunction (15),              -- Equipment
 | 
						|
        excessiveVibration (16),                -- Environmental
 | 
						|
        fileError (17),                         -- Processing
 | 
						|
        fireDetected (18),                      -- Environmental
 | 
						|
        floodDetected (19),                     -- Environmental
 | 
						|
        framingError (20),                      -- Communications
 | 
						|
        heatingOrVentilationOrCoolingSystemProblem (21), -- Environmental
 | 
						|
        humidityUnacceptable (22),              -- Environmental
 | 
						|
        inputDeviceError (23),                  -- Equipment
 | 
						|
        inputOutputDeviceError (24),            -- Equipment
 | 
						|
        lANError (25),                          -- Communications
 | 
						|
        leakDetected (26),                      -- Environmental
 | 
						|
        localNodeTransmissionError (27),        -- Communications
 | 
						|
        lossOfFrame (28),                       -- Communications
 | 
						|
        lossOfSignal (29),                      -- Communications
 | 
						|
        materialSupplyExhausted (30),           -- Environmental
 | 
						|
        multiplexerProblem (31),                -- Equipment
 | 
						|
        outOfMemory (32),                       -- Processing
 | 
						|
        outputDeviceError (33),                 -- Equipment
 | 
						|
        performanceDegraded (34),               -- Quality of service
 | 
						|
        powerProblem (35),                      -- Equipment
 | 
						|
        pressureUnacceptable (36),              -- Environmental
 | 
						|
        processorProblem (37),                  -- Equipment
 | 
						|
        pumpFailure (38),                       -- Environmental
 | 
						|
        queueSizeExceeded (39),                 -- Quality of service
 | 
						|
        receiveFailure (40),                    -- Equipment
 | 
						|
        receiverFailure (41),                   -- Equipment
 | 
						|
        remoteNodeTransmissionError (42),       -- Communications
 | 
						|
        resourceAtOrNearingCapacity (43),       -- Quality of service
 | 
						|
        responseTimeExcessive (44),             -- Quality of service
 | 
						|
        retransmissionRateExcessive (45),       -- Quality of service
 | 
						|
        softwareProgramError (46),              -- Processing
 | 
						|
        softwareError (47),                     -- Processing
 | 
						|
        softwareProgramAbnormallyTerminated (48), -- Processing
 | 
						|
        storageCapacityProblem (49),            -- Processing
 | 
						|
        temperatureUnacceptable (50),           -- Environmental
 | 
						|
        thresholdCrossed (51),                  -- Quality of service
 | 
						|
        timingProblem (52),                     -- Equipment
 | 
						|
        toxicLeakDetected (53),                 -- Environmental
 | 
						|
        transmitFailure (54),                   -- Equipment
 | 
						|
        transmitterFailure (55),                -- Equipment
 | 
						|
        underlyingResourceUnavailable (56),     -- Processing
 | 
						|
        versionMismatch (57) }                  -- Processing
 | 
						|
 | 
						|
 | 
						|
UnitType ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The unit type in the M-Series.
 | 
						|
 | 
						|
         nmb - Network Management Board. The controlling
 | 
						|
         board of the M-Series.
 | 
						|
 | 
						|
         psu1 - The Power Supply in slot 1 of the M-Series.
 | 
						|
 | 
						|
         psu2 - The Power Supply in slot 2 of the M-Series.
 | 
						|
 | 
						|
         fan  - The Fan of the M-Series.
 | 
						|
 | 
						|
         system - The chassis.
 | 
						|
 | 
						|
         slaveNmb - Network Management Board of the Cascading system.
 | 
						|
 | 
						|
         slavePsu1 - The Power Supply in slot 1 of the Cascading M-Series.
 | 
						|
 | 
						|
         slavePsu2 - The Power Supply in slot 2 of the Cascading M-Series.
 | 
						|
 | 
						|
         slaveFan - The Fan of the Cascading M-Series."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        nmb (1),
 | 
						|
        psu1 (2),
 | 
						|
        psu2 (3),
 | 
						|
        fan (4),
 | 
						|
        system (5),
 | 
						|
        slaveNmb (6),
 | 
						|
        slavePsu1 (7),
 | 
						|
        slavePsu2 (8),
 | 
						|
        slaveFan (9)
 | 
						|
    }
 | 
						|
 | 
						|
PortType ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Port direction.
 | 
						|
 | 
						|
         rx - The port direction is receiving(Rx).
 | 
						|
 | 
						|
         tx - The port direction is transmitting(Tx).
 | 
						|
 | 
						|
         biDi - The port direction is both transmitting and receiving."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        rx (1),
 | 
						|
        tx (2),
 | 
						|
        biDi (3)
 | 
						|
    }
 | 
						|
 | 
						|
PortStatus ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "The operational state for a port.
 | 
						|
 | 
						|
        idle - The port is not activated
 | 
						|
 | 
						|
        down - The port traffic is lost.
 | 
						|
 | 
						|
        up - There is traffic on the port.
 | 
						|
 | 
						|
        high - The port got to high power.
 | 
						|
 | 
						|
        low - The port got to low power.
 | 
						|
 | 
						|
        eyeSafety - The Line Tx port is in Eye Safety Mode.
 | 
						|
        This means that either the connector on the
 | 
						|
        Line Tx port is not inserted or that you have
 | 
						|
        too strong reflection from the line fiber.
 | 
						|
 | 
						|
        cd - Channel detected.
 | 
						|
 | 
						|
        ncd - No channel detected."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        idle (1),
 | 
						|
        down (2),
 | 
						|
        up (3),
 | 
						|
        high (4),
 | 
						|
        low (5),
 | 
						|
        eyeSafety (6),
 | 
						|
        cd (7),
 | 
						|
        ncd (8) }
 | 
						|
 | 
						|
PortMode ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Port Mode.
 | 
						|
 | 
						|
         normal - The port is active. Alarms are not suppressed.
 | 
						|
 | 
						|
         service - the port is in Service Mode. Alarms are
 | 
						|
         beeing suppressed. When service is ready the
 | 
						|
         Port Mode should be set back to normal."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        normal (1),
 | 
						|
        service (2)
 | 
						|
    }
 | 
						|
 | 
						|
END
 |