427 lines
		
	
	
		
			14 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			427 lines
		
	
	
		
			14 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
-- *********************************************************************
 | 
						|
-- **
 | 
						|
-- ** BATM Advanced Communications.
 | 
						|
-- **
 | 
						|
-- *********************************************************************
 | 
						|
-- ** Filename: PRVT-LMM-MIB.mib
 | 
						|
-- ** Project: T-Metro Switches.
 | 
						|
-- ** Purpose: Private MIB
 | 
						|
-- *********************************************************************
 | 
						|
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
 | 
						|
-- WARNING:
 | 
						|
--
 | 
						|
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
 | 
						|
--
 | 
						|
-- This file is the property of BATM Advanced Communications and contains
 | 
						|
-- proprietary and confidential information. This file is made
 | 
						|
-- available to authorized BATM customers on the express
 | 
						|
-- condition that neither it, nor any of the information contained
 | 
						|
-- therein, shall be disclosed to third parties or be used for any
 | 
						|
-- purpose other than to replace, modify or upgrade firmware and/or
 | 
						|
-- software components of BATM manufactured equipment within the
 | 
						|
-- authorized customer's network, and that such transfer be
 | 
						|
-- completed in accordance with the instructions provided by
 | 
						|
-- BATM. Any other use is strictly prohibited.
 | 
						|
--
 | 
						|
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
 | 
						|
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
 | 
						|
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
 | 
						|
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
 | 
						|
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
 | 
						|
--
 | 
						|
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
 | 
						|
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
 | 
						|
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
 | 
						|
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
 | 
						|
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
 | 
						|
--
 | 
						|
-- ----------------------------------------------------------------------------
 | 
						|
 | 
						|
PRVT-LMM-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
    ifIndex
 | 
						|
        FROM IF-MIB
 | 
						|
    switch
 | 
						|
        FROM PRVT-SWITCH-MIB
 | 
						|
    Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
 | 
						|
        FROM SNMPv2-SMI
 | 
						|
    TruthValue
 | 
						|
        FROM SNMPv2-TC;
 | 
						|
 | 
						|
prvtLmmMIB MODULE-IDENTITY
 | 
						|
    LAST-UPDATED "201110110000Z"
 | 
						|
    ORGANIZATION 
 | 
						|
        "BATM Advanced Communication"
 | 
						|
    CONTACT-INFO 
 | 
						|
        "BATM/Telco Systems Support team
 | 
						|
         Email:
 | 
						|
         For North America: techsupport@telco.com
 | 
						|
         For North Europe: support@batm.de, info@batm.de
 | 
						|
         For the rest of the world: techsupport@telco.com"
 | 
						|
    DESCRIPTION 
 | 
						|
        "Initial version. This MIB will configure laser monitoring"
 | 
						|
    REVISION    "201110110000Z"
 | 
						|
    DESCRIPTION 
 | 
						|
        "Initial release"
 | 
						|
    ::= { switch 172 }
 | 
						|
 | 
						|
 | 
						|
prvtLmmNotifications OBJECT IDENTIFIER
 | 
						|
    ::= { prvtLmmMIB 0 }
 | 
						|
 | 
						|
prvtLmmObjects OBJECT IDENTIFIER
 | 
						|
    ::= { prvtLmmMIB 1 }
 | 
						|
 | 
						|
prvtLmmShutdown OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Enable/disable laser monitoring"
 | 
						|
    ::= { prvtLmmObjects 1 }
 | 
						|
 | 
						|
prvtLmmDebug OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Enable/Disable laser monitoring"
 | 
						|
    ::= { prvtLmmObjects 2 }
 | 
						|
 | 
						|
prvtLmmPeriod OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the monitoring interval (sec)."
 | 
						|
    ::= { prvtLmmObjects 3 }
 | 
						|
 | 
						|
prvtLmmTrap OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Enable/Disable sending SNMP traps when thresholds are crossed"
 | 
						|
    ::= { prvtLmmObjects 4 }
 | 
						|
 | 
						|
prvtLmmLog OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Enable/Disable alert notification logging when thresholds are crossed"
 | 
						|
    ::= { prvtLmmObjects 5 }
 | 
						|
 | 
						|
prvtLmmLed OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Enable/Disable LED-alert notifications when thresholds are crossed"
 | 
						|
    ::= { prvtLmmObjects 6 }
 | 
						|
 | 
						|
prvtLmmTemperatureHighThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-128..128)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the low threshold value for global temperature (-128 up to 128).
 | 
						|
         prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold"
 | 
						|
    ::= { prvtLmmObjects 7 }
 | 
						|
 | 
						|
prvtLmmTemperatureLowThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-128..128)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the low threshold value for global temperature (-128 up to 128).
 | 
						|
         prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold"
 | 
						|
    ::= { prvtLmmObjects 8 }
 | 
						|
 | 
						|
prvtLmmRxPowerLowThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-40..8)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the low threshold value for global RX-power (-40 up to 8)
 | 
						|
         prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold"
 | 
						|
    ::= { prvtLmmObjects 9 }
 | 
						|
 | 
						|
prvtLmmRxPowerHighThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-40..8)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the high threshold value for global RX-power (-40 up to 8)
 | 
						|
         prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold"
 | 
						|
    ::= { prvtLmmObjects 10 }
 | 
						|
 | 
						|
prvtLmmTxPowerLowThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-40..8)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the low threshold value for global RX-power (-40 up to 8)
 | 
						|
         prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold"
 | 
						|
    ::= { prvtLmmObjects 11 }
 | 
						|
 | 
						|
prvtLmmTxPowerHighThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-40..8)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the high threshold value for global RX-power (-40 up to 8)
 | 
						|
         prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold"
 | 
						|
    ::= { prvtLmmObjects 12 }
 | 
						|
 | 
						|
prvtLmmInterfaceTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF PrvtLmmInterfaceEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Lmm configuration per ethernet port"
 | 
						|
    ::= { prvtLmmObjects 13 }
 | 
						|
 | 
						|
prvtLmmInterfaceEntry OBJECT-TYPE
 | 
						|
    SYNTAX      PrvtLmmInterfaceEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The Stack table entry"
 | 
						|
    INDEX       { ifIndex }
 | 
						|
    ::= { prvtLmmInterfaceTable 1 }
 | 
						|
 | 
						|
PrvtLmmInterfaceEntry ::= SEQUENCE {
 | 
						|
    prvtLmmInterfaceShutdown                TruthValue,
 | 
						|
    prvtLmmInterfaceTempLowThreshold        Integer32,
 | 
						|
    prvtLmmInterfaceTempHighThreshold       Integer32,
 | 
						|
    prvtLmmInterfaceTempValue               Integer32,
 | 
						|
    prvtLmmInterfaceTempThresholdLo         Integer32,
 | 
						|
    prvtLmmInterfaceTempThresholdHi         Integer32,
 | 
						|
    prvtLmmInterfaceTempTestState           TruthValue,
 | 
						|
    prvtLmmInterfaceRxPowerLowThreshold     Integer32,
 | 
						|
    prvtLmmInterfaceRxPowerHighThreshold    Integer32,
 | 
						|
    prvtLmmInterfaceRxPowerValue            Integer32,
 | 
						|
    prvtLmmInterfaceRxPowerThresholdRxLo    Integer32,
 | 
						|
    prvtLmmInterfaceRxPowerThresholdRxHi    Integer32,
 | 
						|
    prvtLmmInterfaceRxPowerTestState        TruthValue,
 | 
						|
    prvtLmmInterfaceTxPowerLowThreshold     Integer32,
 | 
						|
    prvtLmmInterfaceTxPowerHighThreshold    Integer32,
 | 
						|
    prvtLmmInterfaceTxPowerValue            Integer32,
 | 
						|
    prvtLmmInterfaceTxPowerThresholdTxLo    Integer32,
 | 
						|
    prvtLmmInterfaceTxPowerThresholdTxHi    Integer32,
 | 
						|
    prvtLmmInterfaceTxPowerTestState        TruthValue,
 | 
						|
    prvtLmmInterfaceOperStatus              TruthValue
 | 
						|
}
 | 
						|
 | 
						|
prvtLmmInterfaceShutdown OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Enable/Disable laser monitoring on port"
 | 
						|
    ::= { prvtLmmInterfaceEntry 1 }
 | 
						|
 | 
						|
prvtLmmInterfaceTempLowThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-128..128)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the low threshold value for port temperature"
 | 
						|
    ::= { prvtLmmInterfaceEntry 2 }
 | 
						|
 | 
						|
prvtLmmInterfaceTempHighThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-128..128)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the high threshold value for port temperature.
 | 
						|
         Value of prvtLmmInterfaceTempHighThreshold must be greater than 
 | 
						|
         prvtLmmInterfaceTempLowThreshold"
 | 
						|
    ::= { prvtLmmInterfaceEntry 3 }
 | 
						|
 | 
						|
prvtLmmInterfaceTempValue OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Display laser Temperature current value"
 | 
						|
    ::= { prvtLmmInterfaceEntry 4 }
 | 
						|
 | 
						|
prvtLmmInterfaceTempThresholdLo OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The thresholds read from hardware or set by user"
 | 
						|
    ::= { prvtLmmInterfaceEntry 5 }
 | 
						|
 | 
						|
prvtLmmInterfaceTempThresholdHi OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The thresholds read from hardware or set by user"
 | 
						|
    ::= { prvtLmmInterfaceEntry 6 }
 | 
						|
 | 
						|
prvtLmmInterfaceTempTestState OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The state test"
 | 
						|
    ::= { prvtLmmInterfaceEntry 7 }
 | 
						|
 | 
						|
prvtLmmInterfaceRxPowerLowThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-40..8)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the low threshold value for port RX-power."
 | 
						|
    ::= { prvtLmmInterfaceEntry 8 }
 | 
						|
 | 
						|
prvtLmmInterfaceRxPowerHighThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-40..8)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the high threshold value for port RX-power.
 | 
						|
         Value of prvtLmmInterfaceRxPowerHighThreshold must be greater than
 | 
						|
         prvtLmmInterfaceRxPowerLowThreshold"
 | 
						|
    ::= { prvtLmmInterfaceEntry 9 }
 | 
						|
 | 
						|
prvtLmmInterfaceRxPowerValue OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Display laser Rx Power current value"
 | 
						|
    ::= { prvtLmmInterfaceEntry 10 }
 | 
						|
 | 
						|
prvtLmmInterfaceRxPowerThresholdRxLo OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The thresholds read from hardware or set by user"
 | 
						|
    ::= { prvtLmmInterfaceEntry 11 }
 | 
						|
 | 
						|
prvtLmmInterfaceRxPowerThresholdRxHi OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The thresholds read from hardware or set by user"
 | 
						|
    ::= { prvtLmmInterfaceEntry 12 }
 | 
						|
 | 
						|
prvtLmmInterfaceRxPowerTestState OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The state test"
 | 
						|
    ::= { prvtLmmInterfaceEntry 13 }
 | 
						|
 | 
						|
prvtLmmInterfaceTxPowerLowThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-40..8)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the low threshold value for port TX-power"
 | 
						|
    ::= { prvtLmmInterfaceEntry 14 }
 | 
						|
 | 
						|
prvtLmmInterfaceTxPowerHighThreshold OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (-40..8)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Specify the high threshold value for port TX-power
 | 
						|
         Value of prvtLmmInterfaceTxPowerHighThreshold must be greater than
 | 
						|
         prvtLmmInterfaceTxPowerLowThreshold"
 | 
						|
    ::= { prvtLmmInterfaceEntry 15 }
 | 
						|
 | 
						|
prvtLmmInterfaceTxPowerValue OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Display laser Tx Power current value"
 | 
						|
    ::= { prvtLmmInterfaceEntry 16 }
 | 
						|
 | 
						|
prvtLmmInterfaceTxPowerThresholdTxLo OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The thresholds read from hardware or set by user"
 | 
						|
    ::= { prvtLmmInterfaceEntry 17 }
 | 
						|
 | 
						|
prvtLmmInterfaceTxPowerThresholdTxHi OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The thresholds read from hardware or set by user"
 | 
						|
    ::= { prvtLmmInterfaceEntry 18 }
 | 
						|
 | 
						|
prvtLmmInterfaceTxPowerTestState OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The state test"
 | 
						|
    ::= { prvtLmmInterfaceEntry 19 }
 | 
						|
 | 
						|
prvtLmmInterfaceOperStatus OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "Operational status"
 | 
						|
    ::= { prvtLmmInterfaceEntry 20 }
 | 
						|
 | 
						|
prvtLmmTemperatureThresholdCrossed NOTIFICATION-TYPE
 | 
						|
    OBJECTS     { prvtLmmInterfaceTempValue, 
 | 
						|
                  prvtLmmInterfaceTempThresholdHi, 
 | 
						|
                  prvtLmmInterfaceTempThresholdLo }
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The prvtLmmTemperatureThresholdCrossed shall be generated 
 | 
						|
         when prvtLmmInterfaceTempValue rises above prvtLmmInterfaceTempThresholdHi
 | 
						|
         or falls below prvtLmmInterfaceTempThresholdLo. Also the 
 | 
						|
         notification shall be generated when prvtLmmInterfaceTempValue
 | 
						|
         returns to the normal range between prvtLmmInterfaceTempThresholdHi 
 | 
						|
         and prvtLmmInterfaceTempThresholdLo."
 | 
						|
    ::= { prvtLmmNotifications 1 }
 | 
						|
 | 
						|
prvtLmmTxPowerThresholdCrossed NOTIFICATION-TYPE
 | 
						|
    OBJECTS     { prvtLmmInterfaceTxPowerValue, 
 | 
						|
                  prvtLmmInterfaceTxPowerThresholdTxHi, 
 | 
						|
                  prvtLmmInterfaceTxPowerThresholdTxLo }
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The prvtLmmTxPowerThresholdCrossed shall be generated 
 | 
						|
         when prvtLmmInterfaceTxPowerValue rises above prvtLmmInterfaceTxPowerThresholdTxHi
 | 
						|
         or falls below prvtLmmInterfaceTxPowerThresholdTxLo. Also the 
 | 
						|
         notification shall be generated when prvtLmmInterfaceTxPowerValue
 | 
						|
         returns to the normal range between prvtLmmInterfaceTxPowerThresholdTxHi 
 | 
						|
         and prvtLmmInterfaceTxPowerThresholdTxLo."
 | 
						|
    ::= { prvtLmmNotifications 2 }
 | 
						|
 | 
						|
prvtLmmRxPowerThresholdCrossed NOTIFICATION-TYPE
 | 
						|
    OBJECTS     { prvtLmmInterfaceRxPowerValue, 
 | 
						|
                  prvtLmmInterfaceRxPowerThresholdRxHi, 
 | 
						|
                  prvtLmmInterfaceRxPowerThresholdRxLo }
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION 
 | 
						|
        "The prvtLmmRxPowerThresholdCrossed shall be generated 
 | 
						|
         when prvtLmmInterfaceRxPowerValue rises above prvtLmmInterfaceRxPowerThresholdRxHi
 | 
						|
         or falls below prvtLmmInterfaceRxPowerThresholdRxLo. Also the 
 | 
						|
         notification shall be generated when prvtLmmInterfaceRxPowerValue
 | 
						|
         returns to the normal range between prvtLmmInterfaceRxPowerThresholdRxHi 
 | 
						|
         and prvtLmmInterfaceRxPowerThresholdRxLo."
 | 
						|
    ::= { prvtLmmNotifications 3 }
 | 
						|
 | 
						|
END -- end of module PRVT-LMM-MIB.
 |