-rw-r--r--MIBS/asentria/ASENTRIA-ROOT-MIB25
-rw-r--r--MIBS/asentria/SITEBOSS-530-STD-MIB15784
-rw-r--r--MIBS/asentria/SITEBOSS-550-STD-MIB25637
-rw-r--r--MIBS/asentria/SITEBOSS-571-STD-MIB18303
4 files changed, 59749 insertions, 0 deletions
diff --git a/MIBS/asentria/ASENTRIA-ROOT-MIB b/MIBS/asentria/ASENTRIA-ROOT-MIB
new file mode 100644
index 0000000..9c06a6c
--- /dev/null
+++ b/MIBS/asentria/ASENTRIA-ROOT-MIB
@@ -0,0 +1,25 @@
+ASENTRIA-ROOT-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY,
+ enterprises
+ FROM SNMPv2-SMI;
+
+asentria MODULE-IDENTITY
+ LAST-UPDATED "201003090000Z"
+ ORGANIZATION "Asentria Corporation"
+ CONTACT-INFO
+ "Phone: 206-344-8800
+ Fax: 206-344-2116
+ Email: support@asentria.com"
+ DESCRIPTION
+ "Asentria root MIB module"
+ REVISION "201003090000Z"
+ DESCRIPTION
+ "Updated CONTACT-INFO comment."
+ REVISION "200709090000Z"
+ DESCRIPTION
+ "Asentria root MIB module"
+ ::= { enterprises 3052 }
+ --1.3.6.1.4.1.3052
+END
diff --git a/MIBS/asentria/SITEBOSS-530-STD-MIB b/MIBS/asentria/SITEBOSS-530-STD-MIB
new file mode 100644
index 0000000..043c305
--- /dev/null
+++ b/MIBS/asentria/SITEBOSS-530-STD-MIB
@@ -0,0 +1,15784 @@
+-- SiteBoss 530 MIB
+
+-- v 1.43 January 07 2016
+
+-- Copyright (c) 2016 by Asentria Corporation. All rights reserved.
+
+
+SITEBOSS-530-STD-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ DisplayString
+ FROM SNMPv2-TC
+ IpAddress, TimeTicks, Integer32,
+ MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
+ FROM SNMPv2-SMI
+ asentria
+ FROM ASENTRIA-ROOT-MIB;
+
+--***************************************************************************************
+--MODULE IDENTITY
+--***************************************************************************************
+
+ s530 MODULE-IDENTITY
+ LAST-UPDATED "201601070143Z"
+ ORGANIZATION "Asentria Corporation"
+ CONTACT-INFO
+ "Phone: 206-344-8800
+ Fax: 206-344-2116
+ Email: support@asentria.com"
+ DESCRIPTION
+ "MIB module for managing Asentria SiteBoss 530"
+
+ REVISION "201601070143Z"
+ DESCRIPTION
+ "-v1.43
+ -Added Event Sensor Alias and Class OID for event states.
+ -Added Fuel Sensor Fuel Type.
+ -Applicable since unit version 2.11.140."
+
+ REVISION "201504030157Z"
+ DESCRIPTION
+ "-v1.42
+ -Allow read access for serial number, product name, software version
+ -Applicable since unit version 2.10.700."
+
+ REVISION "201412300141Z"
+ DESCRIPTION
+ "-v1.41
+ -Removed wirelessPIN and scSecret objects (OMX-1064).
+ -Applicable since unit version 2.10.610."
+
+ REVISION "201412110140Z"
+ DESCRIPTION
+ "-v1.40
+ -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
+ -Applicable since unit version 2.10.580."
+
+ REVISION "201410160139Z"
+ DESCRIPTION
+ "-v1.39
+ -Added espcAIDisplayFormat object (OMX-1112).
+ -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201410030138Z"
+ DESCRIPTION
+ "-v1.38
+ -Changed analog input objects from Integer32 to DisplayString.
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201408140137Z"
+ DESCRIPTION
+ "-v1.37
+ -Fixed description for wirelessConnIP objects (OMX-1061).
+ -Applicable since unit version 2.10.390."
+
+ REVISION "201407030136Z"
+ DESCRIPTION
+ "-v1.36
+ -Fixed wirelessIdleTimeout (OMX-1037).
+ -Fixed CPE status objects (OMX-1036).
+ -Applicable since unit version 2.10.390."
+
+ REVISION "201406240135Z"
+ DESCRIPTION
+ "-v1.35
+ -Fixed CPE status objects.
+ -Applicable since unit version 2.10.340."
+
+ REVISION "201405290134Z"
+ DESCRIPTION
+ "-v1.34
+ -Added various missing objects (OMX-751).
+ -Added CPE objects (OMX-162).
+ -Applicable since unit version 2.10.320."
+
+ REVISION "201404110133Z"
+ DESCRIPTION
+ "-v1.33
+ -Clarified relay and power output function and documentation (OMX-926).
+ -Applicable since unit version 2.10.300."
+
+ REVISION "201401170132Z"
+ DESCRIPTION
+ "-v1.32
+ -Added power distribution objects (powerDistributionStatus branch) (OMX-708).
+ -Fixed ipRestrictionMask wrong type (OMX-743).
+ -Added ftpPushPermissions (OMX-737).
+ -Applicable since unit version 2.10.150."
+
+ REVISION "201312040131Z"
+ DESCRIPTION
+ "-v1.31
+ -Added fsGenEnable (OMX-661).
+ -Applicable since unit version 2.10.110."
+
+ REVISION "201308010130Z"
+ DESCRIPTION
+ "-v1.30
+ -Added missing trapEventTypeNumber available values in description (OMX-437).
+ -Applicable since unit version 2.09.510."
+
+ REVISION "201306120129Z"
+ DESCRIPTION
+ "-v1.29
+ -Renamed EX10 to Ethernet Expansion (OMX-364)
+ -Applicable since unit version 2.09.510."
+
+ REVISION "201305280128Z"
+ DESCRIPTION
+ "-v1.28
+ -Fixed incorrect SYNTAX for sysCharMask (OMX-328).
+ -Applicable since unit version 2.09.380."
+
+ REVISION "201305100127Z"
+ DESCRIPTION
+ "-v1.27
+ -Fixed incorrect SYNTAX statements for various objects (OMX-314).
+ -Applicable since unit version 2.09.380."
+
+ REVISION "201303150126Z"
+ DESCRIPTION
+ "-v1.26
+ -Renamed sysLocation branch to sysLoc (OMX-198).
+ -Applicable since unit version 2.09.240."
+
+ REVISION "201302060125Z"
+ DESCRIPTION
+ "-v1.25
+ -Added ex10 branch.
+ -Renamed telnet* objects.
+ -Applicable since unit version 2.09.240."
+
+ REVISION "201301140124Z"
+ DESCRIPTION
+ "-v1.24
+ -Added evReset branch and associated notification (OMX-83).
+ -Applicable since unit version 2.09.220."
+
+ REVISION "201211260123Z"
+ DESCRIPTION
+ "-v1.23
+ -Removed ethRouting* objects.
+ -Fixed backwards pppRoutingEnable comment. (BN 4620)"
+
+ REVISION "201208220122Z"
+ DESCRIPTION
+ "-v1.22
+ -Added additional AC power monitor items."
+
+ REVISION "201207090121Z"
+ DESCRIPTION
+ "-v1.21
+ -Removed wirelessBand object."
+
+ REVISION "201206120120Z"
+ DESCRIPTION
+ "-v1.20
+ -Removed user credentials objects."
+
+ REVISION "201205020119Z"
+ DESCRIPTION
+ "-v1.19
+ -Added object for location."
+
+ REVISION "201204050118Z"
+ DESCRIPTION
+ "-v1.18
+ -Added combined eventsensor status objects."
+
+ REVISION "201203060117Z"
+ DESCRIPTION
+ "-v1.17
+ -Added AC power monitor config objects."
+
+ REVISION "201108080900Z"
+ DESCRIPTION
+ "-v1.16
+ -Added s530StockOutputTrap notification definition."
+
+ REVISION "201108010900Z"
+ DESCRIPTION
+ "-v1.15
+ -Added evMgmtReprocess object."
+
+ REVISION "201107080900Z"
+ DESCRIPTION
+ "-v1.14
+ -Added wirelessModemStatus branch."
+
+ REVISION "201101050900Z"
+ DESCRIPTION
+ "-v1.13
+ -Added espcCCNormalThreshold object."
+
+ REVISION "201011030900Z"
+ DESCRIPTION
+ "-v1.12
+ -Changed deadband, threshold, and current values for temperature
+ sensors from integer to floating-point type. This means the
+ SNMP object type for the temperature settings (deadbands and
+ thresholds) changed from Integer32 to DisplayString.
+ -Fixed bug where SNMP integer range defined in the MIB for
+ trapIncludedValue was 16-bit instead of 32-bit."
+
+ REVISION "201008240900Z"
+ DESCRIPTION
+ "-v1.11
+ -Fixed bug where some stock traps had too few varbinds declared.
+ -Removed useless trap definitions."
+
+ REVISION "201003160900Z"
+ DESCRIPTION
+ "-v1.10
+ -Removed useless objects consoleInlineHsk, consoleBaud, consoleFormat, consoleHsk."
+
+ REVISION "201001190900Z"
+ DESCRIPTION
+ "-v1.09
+ -Increased range for esPointValueInt"
+
+ REVISION "200903310900Z"
+ DESCRIPTION
+ "-v1.08
+ -Corrected missing ActionPagerConfig definition."
+
+ REVISION "200811120900Z"
+ DESCRIPTION
+ "-v1.07
+ -Corrected comments for stock trap definitions."
+
+ REVISION "200806090900Z"
+ DESCRIPTION
+ "-v1.06
+ -Added sysLocation branch.
+ -Updated phone numbers in contact info block."
+
+ REVISION "200806021100Z"
+ DESCRIPTION
+ "-v1.05
+ -Added SitePath CPE routing authorization requested stock trap."
+
+ REVISION "200805151500Z"
+ DESCRIPTION
+ "-v1.04
+ -Added pager settings"
+
+ REVISION "200804221652Z"
+ DESCRIPTION
+ "-v1.03
+ -Added missing wireless objects
+ -Removed wirelessBaud object which broke mib walk
+ -Fixed issue where snmpNotificationTx branch was defined wrong."
+
+ REVISION "200804091640Z"
+ DESCRIPTION
+ "-v1.02
+ -Removed scripting object references"
+
+ REVISION "200803211650Z"
+ DESCRIPTION
+ "-v1.01
+ -Added missing CPEDown/VPNGDow notification definitions"
+
+ REVISION "200802131420Z"
+ DESCRIPTION
+ "-v1.00
+ -Initial MIB"
+ ::= { asentria 12 }
+ --1.3.6.1.4.1.3052.12
+
+
+--***************************************************************************************
+--Concise MIB View: Top Level Branches
+--***************************************************************************************
+
+-- status .1
+-- eventSensorStatus .1.1
+-- esPointTable .1.1.1
+-- dataEventStatus .1.2
+-- deStatusTable .1.2.1
+-- modemStatus .1.3
+-- modemCLIDLogTable .1.4
+-- powerDistributionStatus .1.5
+-- fuelSensorStatus .1.6
+-- fsStatusTable .1.6.1
+-- wirelessModemStatus .1.7
+-- acPowerMonitorStatus .1.8
+-- acpmStatusTable .1.8.1
+-- config .2
+-- eventSensorBasics .2.1
+-- esNumberEventSensors .2.1.1
+-- esTable .2.1.2
+-- esNewSensors .2.1.3
+-- eventSensorPointConfig .2.2
+-- esPointConfigTempTable .2.2.1
+-- esPointConfigCCTable .2.2.2
+-- esPointConfigHumidTable .2.2.3
+-- esPointConfigAITable .2.2.5
+-- esPointConfigOutputTable .2.2.6
+-- serialPorts .2.3
+-- numberPorts .2.3.1
+-- portConfigTable .2.3.2
+-- network .2.4
+-- interface .2.4.1
+-- defaultRouter .2.4.2
+-- dnsTable .2.4.3
+-- hostname .2.4.4
+-- hostTable .2.4.5
+-- ncpDuplex .2.4.6
+-- ncpTimeout .2.4.7
+-- snmp .2.4.8
+-- ftpPush .2.4.9
+-- ppp .2.4.10
+-- routing .2.4.11
+-- netSecurity .2.4.12
+-- rts .2.4.13
+-- trap .2.4.14
+-- routeTest .2.4.15
+-- gprs .2.4.16
+-- email .2.4.17
+-- netAdvanced .2.4.18
+-- web .2.4.19
+-- ethExpan .2.4.20
+-- cpe .2.4.22
+-- modem .2.5
+-- time .2.8
+-- clock .2.8.1
+-- console .2.10
+-- unitSecurity .2.11
+-- secCore .2.11.1
+-- secUserTable .2.11.2
+-- secFactory .2.11.3
+-- secVPN .2.11.5
+-- event .2.12
+-- evCore .2.12.1
+-- evData .2.12.2
+-- evNoData1 .2.12.3
+-- evNoData2 .2.12.4
+-- evSched1 .2.12.5
+-- evSched2 .2.12.6
+-- evShskLowTable .2.12.7
+-- evShskHighTable .2.12.8
+-- evNoSensor .2.12.9
+-- fuelSensor .2.12.11
+-- fuelSensorGeneralTable .2.12.11.1
+-- fuelSensorTankTable .2.12.11.2
+-- fuelSensorCustomTankTable .2.12.11.3
+-- fuelSensorVolumeTable .2.12.11.4
+-- fuelSensorDisconnectTable .2.12.11.5
+-- acPowerMonitor .2.12.12
+-- evReset .2.12.16
+-- action .2.14
+-- actionCallNumberTable .2.14.1
+-- actionPagerTable .2.14.2
+-- actionSched .2.14.3
+-- actionAsentria .2.14.4
+-- actionHostTable .2.14.6
+-- actionEmailTable .2.14.7
+-- actionParseError .2.14.8
+-- sys .2.16
+-- sysTime .2.16.1
+-- sysPT .2.16.2
+-- sysMTU .2.16.3
+-- sysAnswerString .2.16.4
+-- sysEventFileID .2.16.6
+-- sysEscapeCharacter .2.16.7
+-- sysTimeStamp .2.16.8
+-- sysLog .2.16.9
+-- sysCRDB .2.16.10
+-- sysCharMask .2.16.11
+-- sysPrompt .2.16.12
+-- sysBootStatus .2.16.13
+-- sysLoc .2.16.14
+-- sysAssetMgmt .2.16.15
+-- auditLog .2.17
+-- productIds .3
+-- siteName 3.1
+-- thisProduct .3.2
+-- stockTrapString .3.3
+-- trapEventTypeNumber .3.4
+-- trapEventTypeName .3.5
+-- trapIncludedValue .3.6
+-- trapIncludedString .3.7
+-- trapTypeString .3.8
+-- trapEventClassNumber .3.9
+-- trapEventClassName .3.10
+-- keyInterface .4.0
+
+--***************************************************************************************
+--Complete MIB View: All Objects
+--***************************************************************************************
+
+-- status .1
+-- eventSensorStatus .1.1
+-- esPointTable .1.1.1
+-- esPointEntry .1.1.1.1
+-- esIndexES .1.1.1.1.1
+-- esIndexPC .1.1.1.1.2
+-- esIndexPoint .1.1.1.1.3
+-- esPointName .1.1.1.1.4
+-- esPointInEventState .1.1.1.1.5
+-- esPointValueInt .1.1.1.1.6
+-- esPointValueStr .1.1.1.1.7
+-- esPointTimeLastChange .1.1.1.1.8
+-- esPointTimetickLastChange .1.1.1.1.9
+-- esPointAliasValueStr .1.1.1.1.10
+-- esPointClassValueStr .1.1.1.1.11
+-- dataEventStatus .1.2
+-- deStatusTable .1.2.1
+-- deStatusEntry .1.2.1.1
+-- deStatusIndex .1.2.1.1.1
+-- deStatusName .1.2.1.1.2
+-- deStatusCounter .1.2.1.1.3
+-- deStatusThreshold .1.2.1.1.4
+-- modemStatus .1.3
+-- modemCLIDLogTable .1.4
+-- modemCLIDLogEntry .1.4.1
+-- modemCLIDLogIndex .1.4.1.1
+-- modemCLIDLogNumber .1.4.1.2
+-- powerDistributionStatus .1.5
+-- pdConfig .1.5.1
+-- pdNextGen .1.5.4
+-- pdnTable .1.5.4.1
+-- pdnEntry .1.5.4.1.1
+-- pdnIndexPD .1.5.4.1.1.1
+-- pdnIndexOutput .1.5.4.1.1.2
+-- pdnConfig .1.5.4.1.1.3
+-- pdnMainCurrentInEventState .1.5.4.1.1.4
+-- pdnMainCurrentValue .1.5.4.1.1.5
+-- pdnMainCurrentValueStr .1.5.4.1.1.6
+-- pdnMainCurrentDeadband .1.5.4.1.1.7
+-- pdnMainCurrentVHighCurrent .1.5.4.1.1.8
+-- pdnMainCurrentHighCurrent .1.5.4.1.1.9
+-- pdnMainCurrentLowCurrent .1.5.4.1.1.10
+-- pdnMainCurrentVLowCurrent .1.5.4.1.1.11
+-- pdnMainVoltageInEventState .1.5.4.1.1.12
+-- pdnMainVoltageValue .1.5.4.1.1.13
+-- pdnMainVoltageValueStr .1.5.4.1.1.14
+-- pdnMainVoltageDeadband .1.5.4.1.1.15
+-- pdnMainVoltageVHighVoltage .1.5.4.1.1.16
+-- pdnMainVoltageHighVoltage .1.5.4.1.1.17
+-- pdnMainVoltageLowVoltage .1.5.4.1.1.18
+-- pdnMainVoltageVLowVoltage .1.5.4.1.1.19
+-- pdnMainPowerValue .1.5.4.1.1.20
+-- pdnMainPowerValueStr .1.5.4.1.1.21
+-- pdnOutputCurrentInEventState .1.5.4.1.1.22
+-- pdnOutputCurrentValue .1.5.4.1.1.23
+-- pdnOutputCurrentValueStr .1.5.4.1.1.24
+-- pdnOutputCurrentDeadband .1.5.4.1.1.25
+-- pdnOutputCurrentVHighCurrent .1.5.4.1.1.26
+-- pdnOutputCurrentHighCurrent .1.5.4.1.1.27
+-- pdnOutputCurrentLowCurrent .1.5.4.1.1.28
+-- pdnOutputCurrentVLowCurrent .1.5.4.1.1.29
+-- pdnOutputFuseInEventState .1.5.4.1.1.30
+-- pdnOutputFuseValueStr .1.5.4.1.1.31
+-- pdnMainCombinedStatus .1.5.4.1.1.32
+-- pdnOutputCombinedStatusBlock1 .1.5.4.1.1.33
+-- pdnOutputCombinedStatusBlock2 .1.5.4.1.1.34
+-- pdnDeviceCurrentValue .1.5.4.1.1.35
+-- pdnDeviceCurrentValueStr .1.5.4.1.1.36
+-- pdSystem .1.5.5
+-- pdSystemCurrent .1.5.5.1
+-- pdSystemPower .1.5.5.2
+-- fuelSensorStatus .1.6
+-- fsStatusTable .1.6.1
+-- fsStatusEntry .1.6.1.1
+-- fsStatusIndex .1.6.1.1.1
+-- fsStatusName .1.6.1.1.2
+-- fsStatusDeviceState .1.6.1.1.3
+-- fsStatusVolumeValueString .1.6.1.1.4
+-- fsStatusVolumePercentLevel .1.6.1.1.7
+-- fsStatusVolumeInEventState .1.6.1.1.8
+-- fsStatusCombined .1.6.1.1.9
+-- wirelessModemStatus .1.7
+-- wmsStatus .1.7.1
+-- wmsSignal .1.7.2
+-- wmsRSSI .1.7.3
+-- wmsBER .1.7.4
+-- wmsUpdated .1.7.5
+-- wmsRegistration .1.7.6
+-- wmsLAC .1.7.7
+-- wmsCellID .1.7.8
+-- wmsIMSI .1.7.9
+-- wmsPhnum .1.7.10
+-- wmsLocalIP .1.7.11
+-- wmsMgfID .1.7.12
+-- wmsModelID .1.7.13
+-- wmsIMEI .1.7.14
+-- wmsRevID .1.7.15
+-- wmsNetName .1.7.16
+-- wmsGPRSStatus .1.7.17
+-- wmsBand .1.7.18
+-- wmsChannel .1.7.19
+-- wmsCountryCode .1.7.20
+-- wmsNetCode .1.7.21
+-- wmsPLMNColor .1.7.22
+-- wmsBScolor .1.7.23
+-- wmsMpRACH .1.7.24
+-- wmsMinRxLevel .1.7.25
+-- wmsBaseCoeff .1.7.26
+-- wmsSIMStatus .1.7.27
+-- wmsICCID .1.7.28
+-- wmsModemType .1.7.29
+-- acPowerMonitorStatus .1.8
+-- acpmStatusTable .1.8.1
+-- acpmStatusEntry .1.8.1.1
+-- acpmsIndex .1.8.1.1.1
+-- acpmsName .1.8.1.1.2
+-- acpmsAvgVoltageValueStr .1.8.1.1.3
+-- acpmsAvgVoltageMinStr .1.8.1.1.4
+-- acpmsAvgVoltageMaxStr .1.8.1.1.5
+-- acpmsAvgVoltageAvgStr .1.8.1.1.6
+-- acpmsAvgVoltageInEventState .1.8.1.1.7
+-- acpmsVoltagePhaseAValueStr .1.8.1.1.8
+-- acpmsVoltagePhaseBValueStr .1.8.1.1.9
+-- acpmsVoltagePhaseCValueStr .1.8.1.1.10
+-- acpmsAvgCurrentValueStr .1.8.1.1.11
+-- acpmsAvgCurrentMinStr .1.8.1.1.12
+-- acpmsAvgCurrentMaxStr .1.8.1.1.13
+-- acpmsAvgCurrentAvgStr .1.8.1.1.14
+-- acpmsAvgCurrentInEventState .1.8.1.1.15
+-- acpmsCurrentPhaseAValueStr .1.8.1.1.16
+-- acpmsCurrentPhaseBValueStr .1.8.1.1.17
+-- acpmsCurrentPhaseCValueStr .1.8.1.1.18
+-- acpmsFreqValueStr .1.8.1.1.19
+-- acpmsFreqMinStr .1.8.1.1.20
+-- acpmsFreqMaxStr .1.8.1.1.21
+-- acpmsFreqAvgStr .1.8.1.1.22
+-- acpmsFreqInEventState .1.8.1.1.23
+-- acpmsTRPValueStr .1.8.1.1.24
+-- acpmsTRPMinStr .1.8.1.1.25
+-- acpmsTRPMaxStr .1.8.1.1.26
+-- acpmsTRPAvgStr .1.8.1.1.27
+-- acpmsTRPInEventState .1.8.1.1.28
+-- acpmsRPPhaseAValueStr .1.8.1.1.29
+-- acpmsRPPhaseBValueStr .1.8.1.1.30
+-- acpmsRPPhaseCValueStr .1.8.1.1.31
+-- acpmsCombined .1.8.1.1.32
+-- acpmsTPFValueStr .1.8.1.1.33
+-- acpmsTPFMinStr .1.8.1.1.34
+-- acpmsTPFMaxStr .1.8.1.1.35
+-- acpmsTPFAvgStr .1.8.1.1.36
+-- acpmsTPFInEventState .1.8.1.1.37
+-- acpmsPFPhaseAValueStr .1.8.1.1.38
+-- acpmsPFPhaseBValueStr .1.8.1.1.39
+-- acpmsPFPhaseCValueStr .1.8.1.1.40
+-- acpmsTRcPValueStr .1.8.1.1.41
+-- acpmsTRcPMinStr .1.8.1.1.42
+-- acpmsTRcPMaxStr .1.8.1.1.43
+-- acpmsTRcPAvgStr .1.8.1.1.44
+-- acpmsRcPPhaseAValueStr .1.8.1.1.45
+-- acpmsRcPPhaseBValueStr .1.8.1.1.46
+-- acpmsRcPPhaseCValueStr .1.8.1.1.47
+-- acpmsTAPValueStr .1.8.1.1.48
+-- acpmsTAPMinStr .1.8.1.1.49
+-- acpmsTAPMaxStr .1.8.1.1.50
+-- acpmsTAPAvgStr .1.8.1.1.51
+-- acpmsAPPhaseAValueStr .1.8.1.1.52
+-- acpmsAPPhaseBValueStr .1.8.1.1.53
+-- acpmsAPPhaseCValueStr .1.8.1.1.54
+-- acpmsTotalEnergyWh .1.8.1.1.55
+-- acpmsTotalEnergyVAR .1.8.1.1.56
+-- acpmsTotalEnergyVA .1.8.1.1.57
+
+-- config .2
+-- eventSensorBasics .2.1
+-- esNumberEventSensors .2.1.1
+-- esTable .2.1.2
+-- esEntry .2.1.2.1
+-- esIndex .2.1.2.1.1
+-- esName .2.1.2.1.2
+-- esID .2.1.2.1.3
+-- esNumberTempSensors .2.1.2.1.4
+-- esTempReportingMode .2.1.2.1.5
+-- esNumberCCs .2.1.2.1.6
+-- esCCReportingMode .2.1.2.1.7
+-- esNumberHumidSensors .2.1.2.1.8
+-- esHumidReportingMode .2.1.2.1.9
+-- esNumberNoiseSensors .2.1.2.1.10
+-- esNoiseReportingMode .2.1.2.1.11
+-- esNumberAirflowSensors .2.1.2.1.12
+-- esAirflowReportingMode .2.1.2.1.13
+-- esNumberAnalog .2.1.2.1.14
+-- esAnalogReportingMode .2.1.2.1.15
+-- esNumberOutputs .2.1.2.1.16
+-- esOutputReportingMode .2.1.2.1.17
+-- esTempCombinedStatus .2.1.2.1.18
+-- esCCCombinedStatusBlock1 .2.1.2.1.19
+-- esCCCombinedStatusBlock2 .2.1.2.1.20
+-- esCCCombinedStatusBlock3 .2.1.2.1.21
+-- esCCCombinedStatusBlock4 .2.1.2.1.22
+-- esCCCombinedStatusBlock5 .2.1.2.1.23
+-- esCCCombinedStatusBlock6 .2.1.2.1.24
+-- esCCCombinedStatusBlock7 .2.1.2.1.25
+-- esCCCombinedStatusBlock8 .2.1.2.1.26
+-- esHumidCombinedStatus .2.1.2.1.27
+-- esAnalogCombinedStatusBlock1 .2.1.2.1.28
+-- esAnalogCombinedStatusBlock2 .2.1.2.1.29
+-- esAnalogCombinedStatusBlock3 .2.1.2.1.30
+-- esAnalogCombinedStatusBlock4 .2.1.2.1.31
+-- esAnalogCombinedStatusBlock5 .2.1.2.1.32
+-- esAnalogCombinedStatusBlock6 .2.1.2.1.33
+-- esOutputCombinedStatusBlock1 .2.1.2.1.34
+-- esOutputCombinedStatusBlock2 .2.1.2.1.35
+-- esNewSensors .2.1.3
+-- eventSensorPointConfig .2.2
+-- esPointConfigTempTable .2.2.1
+-- esPointConfigTempEntry .2.2.1.1
+-- espcTempIndexES .2.2.1.1.1
+-- espcTempIndexPoint .2.2.1.1.2
+-- espcTempEnable .2.2.1.1.3
+-- espcTempScale .2.2.1.1.4
+-- espcTempDeadband .2.2.1.1.5
+-- espcTempVHighTemp .2.2.1.1.6
+-- espcTempVHighActions .2.2.1.1.7
+-- espcTempVHighTrapnum .2.2.1.1.8
+-- espcTempVHighClass .2.2.1.1.9
+-- espcTempHighTemp .2.2.1.1.10
+-- espcTempHighActions .2.2.1.1.11
+-- espcTempHighTrapnum .2.2.1.1.12
+-- espcTempHighClass .2.2.1.1.13
+-- espcTempNormalActions .2.2.1.1.14
+-- espcTempNormalTrapnum .2.2.1.1.15
+-- espcTempNormalClass .2.2.1.1.16
+-- espcTempLowTemp .2.2.1.1.17
+-- espcTempLowActions .2.2.1.1.18
+-- espcTempLowTrapnum .2.2.1.1.19
+-- espcTempLowClass .2.2.1.1.20
+-- espcTempVLowTemp .2.2.1.1.21
+-- espcTempVLowActions .2.2.1.1.22
+-- espcTempVLowTrapnum .2.2.1.1.23
+-- espcTempVLowClass .2.2.1.1.24
+-- esPointConfigCCTable .2.2.2
+-- esPointConfigCCEntry .2.2.2.1
+-- espcCCIndexES .2.2.2.1.1
+-- espcCCIndexPoint .2.2.2.1.2
+-- espcCCEnable .2.2.2.1.3
+-- espcCCName .2.2.2.1.4
+-- espcCCEventState .2.2.2.1.5
+-- espcCCThreshold .2.2.2.1.6
+-- espcCCEventActions .2.2.2.1.7
+-- espcCCEventTrapnum .2.2.2.1.8
+-- espcCCEventClass .2.2.2.1.9
+-- espcCCNormalActions .2.2.2.1.10
+-- espcCCNormalTrapnum .2.2.2.1.11
+-- espcCCNormalClass .2.2.2.1.12
+-- espcCCAlarmAlias .2.2.2.1.13
+-- espcCCNormalAlias .2.2.2.1.14
+-- espcCCNormalThreshold .2.2.2.1.15
+-- espcCCOverrideGlobalReminder .2.2.2.1.16
+-- espcCCReminderInterval .2.2.2.1.17
+-- esPointConfigHumidTable .2.2.3
+-- esPointConfigHumidEntry .2.2.3.1
+-- espcHumidIndexES .2.2.3.1.1
+-- espcHumidIndexPoint .2.2.3.1.2
+-- espcHumidEnable .2.2.3.1.3
+-- espcHumidDeadband .2.2.3.1.4
+-- espcHumidVHighHumid .2.2.3.1.5
+-- espcHumidVHighActions .2.2.3.1.6
+-- espcHumidVHighTrapnum .2.2.3.1.7
+-- espcHumidVHighClass .2.2.3.1.8
+-- espcHumidHighHumid .2.2.3.1.9
+-- espcHumidHighActions .2.2.3.1.10
+-- espcHumidHighTrapnum .2.2.3.1.11
+-- espcHumidHighClass .2.2.3.1.12
+-- espcHumidNormalActions .2.2.3.1.13
+-- espcHumidNormalTrapnum .2.2.3.1.14
+-- espcHumidNormalClass .2.2.3.1.15
+-- espcHumidLowHumid .2.2.3.1.16
+-- espcHumidLowActions .2.2.3.1.17
+-- espcHumidLowTrapnum .2.2.3.1.18
+-- espcHumidLowClass .2.2.3.1.19
+-- espcHumidVLowHumid .2.2.3.1.20
+-- espcHumidVLowActions .2.2.3.1.21
+-- espcHumidVLowTrapnum .2.2.3.1.22
+-- espcHumidVLowClass .2.2.3.1.23
+-- esPointConfigAITable .2.2.5
+-- esPointConfigAIEntry .2.2.5.1
+-- espcAIIndexES .2.2.5.1.1
+-- espcAIIndexPoint .2.2.5.1.2
+-- espcAIEnable .2.2.5.1.3
+-- espcAIDeadband .2.2.5.1.5
+-- espcAIVhighValue .2.2.5.1.6
+-- espcAIVhighActions .2.2.5.1.7
+-- espcAIVhighTrapnum .2.2.5.1.8
+-- espcAIVhighClass .2.2.5.1.9
+-- espcAIHighValue .2.2.5.1.10
+-- espcAIHighActions .2.2.5.1.11
+-- espcAIHighTrapnum .2.2.5.1.12
+-- espcAIHighClass .2.2.5.1.13
+-- espcAINormalActions .2.2.5.1.14
+-- espcAINormalTrapnum .2.2.5.1.15
+-- espcAINormalClass .2.2.5.1.16
+-- espcAILowValue .2.2.5.1.17
+-- espcAILowActions .2.2.5.1.18
+-- espcAILowTrapnum .2.2.5.1.19
+-- espcAILowClass .2.2.5.1.20
+-- espcAIVlowValue .2.2.5.1.21
+-- espcAIVlowActions .2.2.5.1.22
+-- espcAIVlowTrapnum .2.2.5.1.23
+-- espcAIVlowClass .2.2.5.1.24
+-- espcAIConvUnitName .2.2.5.1.25
+-- espcAIConvHighValue .2.2.5.1.26
+-- espcAIConvHighUnit .2.2.5.1.27
+-- espcAIConvLowValue .2.2.5.1.29
+-- espcAIConvLowUnit .2.2.5.1.30
+-- espcAIDisplayFormat .2.2.5.1.32
+-- esPointConfigOutputTable .2.2.6
+-- esPointConfigOutputEntry .2.2.6.1
+-- espcOutputIndexES .2.2.6.1.1
+-- espcOutputIndexPoint .2.2.6.1.2
+-- espcOutputEnable .2.2.6.1.3
+-- espcOutputActiveState .2.2.6.1.4
+-- espcOutputType .2.2.6.1.5
+-- espcOutputAliasValue .2.2.6.1.6
+-- espcOutputAliasColor .2.2.6.1.7
+-- espcOutputActiveAlias .2.2.6.1.10
+-- espcOutputActiveColor .2.2.6.1.11
+-- espcOutputActiveActions .2.2.6.1.12
+-- espcOutputActiveTrapnum .2.2.6.1.13
+-- espcOutputActiveClass .2.2.6.1.14
+-- espcOutputInactiveAlias .2.2.6.1.20
+-- espcOutputInactiveColor .2.2.6.1.21
+-- espcOutputInactiveActions .2.2.6.1.22
+-- espcOutputInactiveTrapnum .2.2.6.1.23
+-- espcOutputInactiveClass .2.2.6.1.24
+-- serialPorts .2.3
+-- numberPorts .2.3.1
+-- portConfigTable .2.3.2
+-- portConfigEntry .2.3.2.1
+-- portConfigIndex .2.3.2.1.1
+-- portConfigBaud .2.3.2.1.2
+-- portConfigDataFormat .2.3.2.1.3
+-- portConfigStripPtOutputLfs .2.3.2.1.4
+-- portConfigStripPtInputLfs .2.3.2.1.5
+-- portConfigMaskEnable .2.3.2.1.7
+-- portConfigDAEnable .2.3.2.1.8
+-- portConfigStoreAlarmsDPT .2.3.2.1.9
+-- portConfigRecordTimeout .2.3.2.1.10
+-- portConfigDataType .2.3.2.1.11
+-- portConfigEtxToCRLF .2.3.2.1.12
+-- portConfigMLREnable .2.3.2.1.13
+-- portConfigMLRStartField1Pos .2.3.2.1.14
+-- portConfigMLRStartField1Text .2.3.2.1.15
+-- portConfigMLRStartField2Pos .2.3.2.1.16
+-- portConfigMLRStartField2Text .2.3.2.1.17
+-- portConfigMLRNumLinesBefore .2.3.2.1.18
+-- portConfigMLREndDetection .2.3.2.1.19
+-- portConfigMLRLineCount .2.3.2.1.20
+-- portConfigMLREndField1Pos .2.3.2.1.21
+-- portConfigMLREndField1Text .2.3.2.1.22
+-- portConfigMLREndField2Pos .2.3.2.1.23
+-- portConfigMLREndField2Text .2.3.2.1.24
+-- portConfigMLRUseComplexRules .2.3.2.1.25
+-- portConfigBufferPT .2.3.2.1.26
+-- portConfigId .2.3.2.1.27
+-- portConfigMode .2.3.2.1.28
+-- portConfigHsk .2.3.2.1.29
+-- network .2.4
+-- interface .2.4.1
+-- ethernet .2.4.1.1
+-- ethernet1 .2.4.1.1.1
+-- eth1Mode .2.4.1.1.1.1
+-- eth1Address .2.4.1.1.1.2
+-- eth1SubnetMask .2.4.1.1.1.3
+-- eth1Router .2.4.1.1.1.4
+-- eth1MAC .2.4.1.1.1.6
+-- ethernet2 .2.4.1.1.2
+-- eth2Mode .2.4.1.1.2.1
+-- eth2Address .2.4.1.1.2.2
+-- eth2SubnetMask .2.4.1.1.2.3
+-- eth2Router .2.4.1.1.2.4
+-- eth2MAC .2.4.1.1.2.6
+-- defaultRouter .2.4.2
+-- dnsTable .2.4.3
+-- dnsEntry .2.4.3.1
+-- dnsIndex .2.4.3.1.1
+-- dnsAddress .2.4.3.1.2
+-- hostname .2.4.4
+-- hostTable .2.4.5
+-- hostEntry .2.4.5.1
+-- hostIndex .2.4.5.1.1
+-- hostDeclaration .2.4.5.1.2
+-- ncpDuplex .2.4.6
+-- ncpTimeout .2.4.7
+-- snmp .2.4.8
+-- snmpAgentEnable .2.4.8.1
+-- snmpNotificationCaptureEnable .2.4.8.5
+-- snmpNotificationCaptureFile .2.4.8.6
+-- snmpNotificationTx .2.4.8.7
+-- snmpNtfnAttempts .2.4.8.7.1
+-- snmpNtfnTimeout .2.4.8.7.2
+-- snmpNtfnCycles .2.4.8.7.3
+-- snmpNtfnSnooze .2.4.8.7.4
+-- ftpPush .2.4.9
+-- ftpPushEnable .2.4.9.1
+-- ftpPushServer .2.4.9.2
+-- ftpPushAccount .2.4.9.5
+-- ftpPushDirectory .2.4.9.6
+-- ftpPushperiod .2.4.9.7
+-- ftpPushPushFileTable .2.4.9.8
+-- ftpPushPushFileEntry .2.4.9.8.1
+-- ftpPushPushFileIndex .2.4.9.8.1.1
+-- ftpPushPushFile .2.4.9.8.1.2
+-- ftpPushPushAudit .2.4.9.9
+-- ftpPushPushAlarms .2.4.9.10
+-- ftpPushRemoteFileTable .2.4.9.11
+-- ftpPushRemoteFileEntry .2.4.9.11.1
+-- ftpPushRemoteFileIndex .2.4.9.11.1.1
+-- ftpPushRemoteFileName .2.4.9.11.1.2
+-- ftpPushRemoteAlarmName .2.4.9.12
+-- ftpPushPassive .2.4.9.13
+-- ftpPushIncludeDate .2.4.9.14
+-- ftpPushIncludeTime .2.4.9.15
+-- ftpPushIncludeSeq .2.4.9.16
+-- ftpPushPermissions .2.4.9.17
+-- ppp .2.4.10
+-- pppDial .2.4.10.1
+-- pppDialEnable .2.4.10.1.1
+-- pppDialNumber .2.4.10.1.2
+-- pppDialIdleTimeout .2.4.10.1.5
+-- pppDialRetries .2.4.10.1.6
+-- pppDialCDTimeout .2.4.10.1.7
+-- pppDialLoginTimeout .2.4.10.1.8
+-- pppDialMdmInit .2.4.10.1.9
+-- pppDialSuggestIP .2.4.10.1.10
+-- pppDialPlainLogin .2.4.10.1.11
+-- pppHost .2.4.10.2
+-- pppHostEnable .2.4.10.2.1
+-- pppHostIdleTimeout .2.4.10.2.2
+-- pppHostLocalIP .2.4.10.2.3
+-- pppHostRemoteIP .2.4.10.2.4
+-- routing .2.4.11
+-- pppRoutingEnable .2.4.11.1
+-- routingInterface .2.4.11.4
+-- netSecurity .2.4.12
+-- ipRestriction .2.4.12.1
+-- ipRestrictionTable .2.4.12.1.1
+-- ipRestrictionEntry .2.4.12.1.1.1
+-- ipRestrictionIndex .2.4.12.1.1.1.1
+-- ipRestrictionEnable .2.4.12.1.1.1.2
+-- ipRestrictionMask .2.4.12.1.1.1.3
+-- rts .2.4.13
+-- rtsFileTable .2.4.13.1
+-- rtsFileEntry .2.4.13.1.1
+-- rtsFileIndex .2.4.13.1.1.1
+-- rtsFileMode .2.4.13.1.1.2
+-- rtsFileShowAnswer .2.4.13.1.1.3
+-- rtsFileReqXON .2.4.13.1.1.4
+-- rtsFileTimeout .2.4.13.1.1.5
+-- rtsFileEmptyClose .2.4.13.1.1.6
+-- rtsFilePushHost .2.4.13.1.1.7
+-- rtsFilePushPort .2.4.13.1.1.8
+-- rtsFilePushRetryTimer .2.4.13.1.1.9
+-- rtsAlarms .2.4.13.2
+-- rtsAlarmsMode .2.4.13.2.1
+-- rtsAlarmsShowAnswer .2.4.13.2.2
+-- rtsAlarmsReqXON .2.4.13.2.3
+-- rtsAlarmsTimeout .2.4.13.2.4
+-- rtsAlarmsEmptyClose .2.4.13.2.5
+-- rtsAlarmsPushHost .2.4.13.2.6
+-- rtsAlarmsPushPort .2.4.13.2.7
+-- rtsAlarmsPushRetryTimer .2.4.13.2.8
+-- trap .2.4.14
+-- trapInclude .2.4.14.1
+-- trapIncludeDateTime .2.4.14.1.1
+-- trapIncludeSiteName .2.4.14.1.2
+-- trapIncludeSensorID .2.4.14.1.3
+-- trapIncludeUDName .2.4.14.1.4
+-- trapIncludeUDState .2.4.14.1.5
+-- trapIncludeSourceAddress .2.4.14.1.6
+-- trapAuthFailEnable .2.4.14.2
+-- routeTest .2.4.15
+-- routeTestEnable .2.4.15.1
+-- routeTestPeriod .2.4.15.2
+-- routeTestAddressTable .2.4.15.3
+-- routeTestAddressEntry .2.4.15.3.1
+-- routeTestAddressIndex .2.4.15.3.1.1
+-- routeTestAddress .2.4.15.3.1.2
+-- wireless .2.4.16
+-- wirelessMode .2.4.16.1
+-- wirelessAPN .2.4.16.2
+-- wirelessIdleTimeout .2.4.16.3
+-- wirelessDRE .2.4.16.9
+-- wirelessPPPUsername .2.4.16.10
+-- wirelessFirewall .2.4.16.11
+-- wirelessKeepaliveThreshold .2.4.16.12
+-- wirelessPPPDebug .2.4.16.13
+-- wirelessConnectivity .2.4.16.20
+-- wirelessConnEnable .2.4.16.20.1
+-- wirelessConnCheckInterval .2.4.16.20.2
+-- wirelessConnFailThreshold .2.4.16.20.3
+-- wirelessConnIP1 .2.4.16.20.10
+-- wirelessConnIP2 .2.4.16.20.11
+-- email .2.4.17
+-- emailServer .2.4.17.1
+-- emailDomain .2.4.17.2
+-- emailAuthEnable .2.4.17.3
+-- netAdvanced .2.4.18
+-- arpFilter .2.4.18.1
+-- web .2.4.19
+-- webEnable .2.4.19.1
+-- webPort .2.4.19.1
+-- webTimeout .2.4.19.1
+-- ethExpan .2.4.20
+-- ethExpanIp .2.4.20.1
+-- ethExpanMask .2.4.20.2
+-- ethExpanCardTable .2.4.20.3
+-- ethExpanCardEntry .2.4.20.3.1
+-- ethExpanCardIndex .2.4.20.3.1.1
+-- ethExpanCardMAC .2.4.20.3.1.2
+-- ethExpanDHCP .2.4.20.6
+-- ethExpanDHCPStartIp .2.4.20.6.1
+-- ethExpanDHCPLeaseTime .2.4.20.6.2
+-- cpe .2.4.22
+-- cpeTable .2.4.22.1
+-- cpeEntry .2.4.22.1.1
+-- cpeIndex .2.4.22.1.1.1
+-- cpeHost .2.4.22.1.1.2
+-- cpeName .2.4.22.1.1.3
+-- cpeDescription .2.4.22.1.1.4
+-- cpeKeepalive .2.4.22.1.1.5
+-- cpeThreshold .2.4.22.1.1.6
+-- cpeEventReminderInterval .2.4.22.1.1.7
+-- cpeKeepaliveTicks .2.4.22.1.1.20
+-- cpePingSize .2.4.22.1.1.21
+-- cpeInfoReset .2.4.22.1.1.30
+-- cpeInfoNumReq .2.4.22.1.1.31
+-- cpeInfoNumGoodResp .2.4.22.1.1.32
+-- cpeInfoNumBadResp .2.4.22.1.1.33
+-- cpeInfoNumLostResp .2.4.22.1.1.34
+-- cpeInfoPercentLoss .2.4.22.1.1.35
+-- cpeInfoPercentBad .2.4.22.1.1.36
+-- modem .2.5
+-- modemFormat .2.5.1
+-- modemInitString .2.5.2
+-- modemCallAttempts .2.5.4
+-- modemCallDelay .2.5.5
+-- modemCmdTimout .2.5.6
+-- modemGoto .2.5.7
+-- modemClid .2.5.8
+-- modemCLIDEnable .2.5.8.1
+-- modemCLIDNumberTable .2.5.8.2
+-- modemCLIDNumberEntry .2.5.8.2.1
+-- modemCLIDNumberIndex .2.5.8.2.1.1
+-- modemCLIDNumber .2.5.8.2.1.2
+-- modemTAPInitString .2.5.9
+-- modemTAP8N1 .2.5.10
+-- time .2.8
+-- clock .2.8.1
+-- console .2.10
+-- consoleDuplex .2.10.1
+-- consoleTimeout .2.10.2
+-- consoleConfirm .2.10.7
+-- unitSecurity .2.11
+-- secCore .2.11.1
+-- scShowPasswordPrompt .2.11.1.1
+-- scConsoleLoginRequired .2.11.1.2
+-- scModemLoginRequired .2.11.1.3
+-- scTelnetLoginRequired .2.11.1.4
+-- scTelnetPTLoginRequired .2.11.1.5
+-- scRTSLoginRequired .2.11.1.6
+-- scAuthMode .2.11.1.7
+-- scRightsGroup .2.11.1.8
+-- secUserTable .2.11.2
+-- secUserEntry .2.11.2.1
+-- secUserIndex .2.11.2.1.1
+-- secUserEnable .2.11.2.1.2
+-- secUserConnectVia .2.11.2.1.5
+-- secUserLoginTo .2.11.2.1.6
+-- secUserAccessFile .2.11.2.1.7
+-- secUserPTEscapeTo .2.11.2.1.9
+-- secUserPPPType .2.11.2.1.10
+-- secUserRights .2.11.2.1.11
+-- secUserEventsReadAccess .2.11.2.1.13
+-- secUserAuditReadAccess .2.11.2.1.14
+-- secUserEventsWriteAccess .2.11.2.1.16
+-- secUserAuditWriteAccess .2.11.2.1.17
+-- secUserExpiration .2.11.2.1.18
+-- secUserCallbackNumber1 .2.11.2.1.19
+-- secUserCallbackNumber2 .2.11.2.1.20
+-- secUserCallbackNumber3 .2.11.2.1.21
+-- secUserChallengeTelnetMode .2.11.2.1.22
+-- secUserChallengeModemMode .2.11.2.1.23
+-- secUserChallengeConsoleMode .2.11.2.1.24
+-- secUserChallengeTelnetSendTo .2.11.2.1.25
+-- secUserChallengeModemSendTo .2.11.2.1.26
+-- secUserChallengeExpiration .2.11.2.1.27
+-- secFactory .2.11.3
+-- sfEnable .2.11.3.1
+-- sfSecret .2.11.3.2
+-- secVPN .2.11.5
+-- event .2.12
+-- evCore .2.12.1
+-- evClassNameTable .2.12.1.1
+-- evClassNameEntry .2.12.1.1.1
+-- evClassNameIndex .2.12.1.1.1.1
+-- evClassName .2.12.1.1.1.2
+-- evReminderInterval .2.12.1.2
+-- evLog .2.12.1.3
+-- evLogEnable .2.12.1.3.1
+-- evLogStoreAlarm .2.12.1.3.2
+-- evLogMaxSize .2.12.1.3.3
+-- evLogStoreSensor .2.12.1.3.4
+-- evLogTimeStampAlarms .2.12.1.3.5
+-- evLogPrependName .2.12.1.3.6
+-- evMgmt .2.12.1.4
+-- evMgmtReprocess .2.12.1.4.3
+-- evData .2.12.2
+-- evdCore .2.12.2.1
+-- evdExitOnTrue .2.12.2.1.1
+-- evdFilterAction .2.12.2.1.2
+-- evdWildCardChar .2.12.2.1.3
+-- evdTable .2.12.2.2
+-- evdEntry .2.12.2.2.1
+-- evdIndex .2.12.2.2.1.1
+-- evdEnable .2.12.2.2.1.2
+-- evdName .2.12.2.2.1.3
+-- evdEquation .2.12.2.2.1.4
+-- evdThreshold .2.12.2.2.1.5
+-- evdAutoclear .2.12.2.2.1.6
+-- evdClearInterval .2.12.2.2.1.7
+-- evdClearTime .2.12.2.2.1.8
+-- evdActions .2.12.2.2.1.9
+-- evdClass .2.12.2.2.1.10
+-- evdTrapNum .2.12.2.2.1.11
+-- evdMode .2.12.2.2.1.12
+-- evdFieldTable .2.12.2.3
+-- evdFieldEntry .2.12.2.3.1
+-- evdFieldIndex .2.12.2.3.1.1
+-- evdFieldStart .2.12.2.3.1.2
+-- evdFieldLength .2.12.2.3.1.3
+-- evdFieldName .2.12.2.3.1.4
+-- evdFieldLine .2.12.2.3.1.5
+-- evdFieldType .2.12.2.3.1.6
+-- evdMacroTable .2.12.2.4
+-- evdMacroEntry .2.12.2.4.1
+-- evdMacroIndex .2.12.2.4.1.1
+-- evdMacroName .2.12.2.4.1.2
+-- evdMacroEquation .2.12.2.4.1.3
+-- evNoData1 .2.12.3
+-- evNoData1Enable .2.12.3.1
+-- evNoData1Actions .2.12.3.2
+-- evNoData1Message .2.12.3.3
+-- evNoData1TrapNum .2.12.3.4
+-- evNoData1Class .2.12.3.5
+-- evNoData1Sched1Begin .2.12.3.6
+-- evNoData1Sched1End .2.12.3.7
+-- evNoData1Sched1Duration .2.12.3.8
+-- evNoData1Sched2Begin .2.12.3.9
+-- evNoData1Sched2End .2.12.3.10
+-- evNoData1Sched2Duration .2.12.3.11
+-- evNoData1PortEnableTable .2.12.3.12
+-- evNoData1PortEnableEntry .2.12.3.12.1
+-- evNoData1PortEnableIndex .2.12.3.12.1.1
+-- evNoData1PortEnable .2.12.3.12.1.2
+-- evNoData1Exclusions .2.12.3.13
+-- evNoData1Days .2.12.3.14
+-- evNoData2 .2.12.4
+-- evNoData2Enable .2.12.4.1
+-- evNoData2Actions .2.12.4.2
+-- evNoData2Message .2.12.4.3
+-- evNoData2TrapNum .2.12.4.4
+-- evNoData2Class .2.12.4.5
+-- evNoData2Sched1Begin .2.12.4.6
+-- evNoData2Sched1End .2.12.4.7
+-- evNoData2Sched1Duration .2.12.4.8
+-- evNoData2Sched2Begin .2.12.4.9
+-- evNoData2Sched2End .2.12.4.10
+-- evNoData2Sched2Duration .2.12.4.11
+-- evNoData2PortEnableTable .2.12.4.12
+-- evNoData2PortEnableEntry .2.12.4.12.1
+-- evNoData2PortEnableIndex .2.12.4.12.1.1
+-- evNoData2PortEnable .2.12.4.12.1.2
+-- evNoData2Exclusions .2.12.4.13
+-- evNoData2Days .2.12.4.14
+-- evSched1 .2.12.5
+-- evSched1Enable .2.12.5.1
+-- evSched1Actions .2.12.5.2
+-- evSched1Message .2.12.5.3
+-- evSched1TrapNum .2.12.5.4
+-- evSched1Class .2.12.5.5
+-- evSched1Sunday .2.12.5.6
+-- evSched1Monday .2.12.5.7
+-- evSched1Tuesday .2.12.5.8
+-- evSched1Wednesday .2.12.5.9
+-- evSched1Thursday .2.12.5.10
+-- evSched1Friday .2.12.5.11
+-- evSched1Saturday .2.12.5.12
+-- evSched1Exclusions .2.12.5.13
+-- evSched2 .2.12.6
+-- evSched2Enable .2.12.6.1
+-- evSched2Actions .2.12.6.2
+-- evSched2Message .2.12.6.3
+-- evSched2TrapNum .2.12.6.4
+-- evSched2Class .2.12.6.5
+-- evSched2Sunday .2.12.6.6
+-- evSched2Monday .2.12.6.7
+-- evSched2Tuesday .2.12.6.8
+-- evSched2Wednesday .2.12.6.9
+-- evSched2Thursday .2.12.6.10
+-- evSched2Friday .2.12.6.11
+-- evSched2Saturday .2.12.6.12
+-- evSched2Exclusions .2.12.6.13
+-- evShskLowTable .2.12.7
+-- evShskLowEntry .2.12.7.1
+-- evShskLowIndex .2.12.7.1.1
+-- evShskLowEnable .2.12.7.1.2
+-- evShskLowActions .2.12.7.1.3
+-- evShskLowMessage .2.12.7.1.4
+-- evShskLowClass .2.12.7.1.5
+-- evShskLowTrapNum .2.12.7.1.6
+-- evShskHighTable .2.12.8
+-- evShskHighEntry .2.12.8.1
+-- evShskHighIndex .2.12.8.1.1
+-- evShskHighEnable .2.12.8.1.2
+-- evShskHighActions .2.12.8.1.3
+-- evShskHighMessage .2.12.8.1.4
+-- evShskHighClass .2.12.8.1.5
+-- evShskHighTrapNum .2.12.8.1.6
+-- evNoSensor .2.12.9
+-- evNoSensorTimeout .2.12.9.1
+-- evNoSensorActions .2.12.9.2
+-- evNoSensorTrapNum .2.12.9.3
+-- evNoSensorClass .2.12.9.4
+-- fuelSensor .2.12.11
+-- fuelSensorGeneralTable .2.12.11.1
+-- fsGenEntry .2.12.11.1.1
+-- fsGenIndex .2.12.11.1.1.1
+-- fsGenName .2.12.11.1.1.2
+-- fsGenSensorType .2.12.11.1.1.3
+-- fsGenDistanceUnit .2.12.11.1.1.4
+-- fsGenRawValueTop .2.12.11.1.1.5
+-- fsGenTopOffset .2.12.11.1.1.6
+-- fsGenRawValueBottom .2.12.11.1.1.7
+-- fsGenBottomOffset .2.12.11.1.1.8
+-- fsGenInputES .2.12.11.1.1.9
+-- fsGenInputPoint .2.12.11.1.1.10
+-- fsGenFilterAveraging .2.12.11.1.1.11
+-- fsGenSysrepEnable .2.12.11.1.1.12
+-- fsGenSysrepThreshold .2.12.11.1.1.13
+-- fsGenSysrepLimit .2.12.11.1.1.14
+-- fsGenSysrepPackage .2.12.11.1.1.15
+-- fsGenSysrepType .2.12.11.1.1.16
+-- fsGenEnable .2.12.11.1.1.17
+-- fsGenFuelType .2.12.11.1.1.18
+-- fuelSensorTankTable .2.12.11.2
+-- fsTankEntry .2.12.11.2.1
+-- fsTankIndex .2.12.11.2.1.1
+-- fsTankHeight .2.12.11.2.1.2
+-- fsTankDimA .2.12.11.2.1.3
+-- fsTankDimB .2.12.11.2.1.4
+-- fsTankVolume .2.12.11.2.1.5
+-- fsTankVolumeUnit .2.12.11.2.1.6
+-- fsTankShape .2.12.11.2.1.7
+-- fuelSensorCustomTankTable .2.12.11.3
+-- fsCustomTankEntry .2.12.11.3.1
+-- fsCustomTankIndexFS .2.12.11.3.1.1
+-- fsCustomTankIndexDatum .2.12.11.3.1.2
+-- fsCustomTankHeight .2.12.11.3.1.3
+-- fsCustomTankVolume .2.12.11.3.1.4
+-- fuelSensorVolumeTable .2.12.11.4
+-- fsVolumeEntry .2.12.11.4.1
+-- fsVolumeIndex .2.12.11.4.1.1
+-- fsVolumeEnable .2.12.11.4.1.2
+-- fsVolumeDeadband .2.12.11.4.1.3
+-- fsVolumeVHighValue .2.12.11.4.1.4
+-- fsVolumeVHighActions .2.12.11.4.1.5
+-- fsVolumeVHighTrapNum .2.12.11.4.1.6
+-- fsVolumeVHighClass .2.12.11.4.1.7
+-- fsVolumeHighValue .2.12.11.4.1.8
+-- fsVolumeHighActions .2.12.11.4.1.9
+-- fsVolumeHighTrapNum .2.12.11.4.1.10
+-- fsVolumeHighClass .2.12.11.4.1.11
+-- fsVolumeNormalActions .2.12.11.4.1.12
+-- fsVolumeNormalTrapNum .2.12.11.4.1.13
+-- fsVolumeNormalClass .2.12.11.4.1.14
+-- fsVolumeLowValue .2.12.11.4.1.15
+-- fsVolumeLowActions .2.12.11.4.1.16
+-- fsVolumeLowTrapNum .2.12.11.4.1.17
+-- fsVolumeLowClass .2.12.11.4.1.18
+-- fsVolumeVLowValue .2.12.11.4.1.19
+-- fsVolumeVLowActions .2.12.11.4.1.20
+-- fsVolumeVLowTrapNum .2.12.11.4.1.21
+-- fsVolumeVLowClass .2.12.11.4.1.22
+-- fuelSensorDisconnectTable .2.12.11.5
+-- fsDiscEntry .2.12.11.5.1
+-- fsDiscIndex .2.12.11.5.1.1
+-- fsDiscEnable .2.12.11.5.1.2
+-- fsDiscHighValue .2.12.11.5.1.3
+-- fsDiscLowValue .2.12.11.5.1.4
+-- fsDiscActions .2.12.11.5.1.5
+-- fsDiscTrapNum .2.12.11.5.1.6
+-- fsDiscClass .2.12.11.5.1.7
+-- fsDiscNormalActions .2.12.11.5.1.8
+-- fsDiscNormalTrapNum .2.12.11.5.1.9
+-- fsDiscNormalClass .2.12.11.5.1.10
+-- acPowerMonitor .2.12.12
+-- acpmGeneralTable .2.12.12.1
+-- acpmGenEntry .2.12.12.1.1
+-- acpmGenIndex .2.12.12.1.1.1
+-- acpmGenDevice .2.12.12.1.1.2
+-- acpmGenName .2.12.12.1.1.3
+-- acpmGenAddress .2.12.12.1.1.4
+-- acpmGenPtRatio .2.12.12.1.1.5
+-- acpmGenCtRatio .2.12.12.1.1.6
+-- acpmGenPowerType .2.12.12.1.1.7
+-- acpmGenSysrepPackage .2.12.12.1.1.8
+-- acpmGenSysrepType .2.12.12.1.1.9
+-- acpmGenEnable .2.12.12.1.1.10
+-- acpmAvgVoltageTable .2.12.12.2
+-- acpmAvgVoltageEntry .2.12.12.2.1
+-- acpmAvgVoltageIndex .2.12.12.2.1.1
+-- acpmAvgVoltageEnable .2.12.12.2.1.2
+-- acpmAvgVoltageDeadband .2.12.12.2.1.3
+-- acpmAvgVoltageVHighValue .2.12.12.2.1.4
+-- acpmAvgVoltageVHighActions .2.12.12.2.1.5
+-- acpmAvgVoltageVHighTrapNum .2.12.12.2.1.6
+-- acpmAvgVoltageVHighClass .2.12.12.2.1.7
+-- acpmAvgVoltageHighValue .2.12.12.2.1.8
+-- acpmAvgVoltageHighActions .2.12.12.2.1.9
+-- acpmAvgVoltageHighTrapNum .2.12.12.2.1.10
+-- acpmAvgVoltageHighClass .2.12.12.2.1.11
+-- acpmAvgVoltageNormalActions .2.12.12.2.1.12
+-- acpmAvgVoltageNormalTrapNum .2.12.12.2.1.13
+-- acpmAvgVoltageNormalClass .2.12.12.2.1.14
+-- acpmAvgVoltageLowValue .2.12.12.2.1.15
+-- acpmAvgVoltageLowActions .2.12.12.2.1.16
+-- acpmAvgVoltageLowTrapNum .2.12.12.2.1.17
+-- acpmAvgVoltageLowClass .2.12.12.2.1.18
+-- acpmAvgVoltageVLowValue .2.12.12.2.1.19
+-- acpmAvgVoltageVLowActions .2.12.12.2.1.20
+-- acpmAvgVoltageVLowTrapNum .2.12.12.2.1.21
+-- acpmAvgVoltageVLowClass .2.12.12.2.1.22
+-- acpmAvgVoltageSysrepEnable .2.12.12.2.1.23
+-- acpmAvgVoltageSysrepThreshold .2.12.12.2.1.24
+-- acpmAvgVoltageSysrepLimit .2.12.12.2.1.25
+-- acpmAvgCurrentTable .2.12.12.3
+-- acpmAvgCurrentEntry .2.12.12.3.1
+-- acpmAvgCurrentIndex .2.12.12.3.1.1
+-- acpmAvgCurrentEnable .2.12.12.3.1.2
+-- acpmAvgCurrentDeadband .2.12.12.3.1.3
+-- acpmAvgCurrentVHighValue .2.12.12.3.1.4
+-- acpmAvgCurrentVHighActions .2.12.12.3.1.5
+-- acpmAvgCurrentVHighTrapNum .2.12.12.3.1.6
+-- acpmAvgCurrentVHighClass .2.12.12.3.1.7
+-- acpmAvgCurrentHighValue .2.12.12.3.1.8
+-- acpmAvgCurrentHighActions .2.12.12.3.1.9
+-- acpmAvgCurrentHighTrapNum .2.12.12.3.1.10
+-- acpmAvgCurrentHighClass .2.12.12.3.1.11
+-- acpmAvgCurrentNormalActions .2.12.12.3.1.12
+-- acpmAvgCurrentNormalTrapNum .2.12.12.3.1.13
+-- acpmAvgCurrentNormalClass .2.12.12.3.1.14
+-- acpmAvgCurrentLowValue .2.12.12.3.1.15
+-- acpmAvgCurrentLowActions .2.12.12.3.1.16
+-- acpmAvgCurrentLowTrapNum .2.12.12.3.1.17
+-- acpmAvgCurrentLowClass .2.12.12.3.1.18
+-- acpmAvgCurrentVLowValue .2.12.12.3.1.19
+-- acpmAvgCurrentVLowActions .2.12.12.3.1.20
+-- acpmAvgCurrentVLowTrapNum .2.12.12.3.1.21
+-- acpmAvgCurrentVLowClass .2.12.12.3.1.22
+-- acpmAvgCurrentSysrepEnable .2.12.12.3.1.23
+-- acpmAvgCurrentSysrepThreshold .2.12.12.3.1.24
+-- acpmAvgCurrentSysrepLimit .2.12.12.3.1.25
+-- acpmFreqTable .2.12.12.4
+-- acpmFreqEntry .2.12.12.4.1
+-- acpmFreqIndex .2.12.12.4.1.1
+-- acpmFreqEnable .2.12.12.4.1.2
+-- acpmFreqDeadband .2.12.12.4.1.3
+-- acpmFreqVHighValue .2.12.12.4.1.4
+-- acpmFreqVHighActions .2.12.12.4.1.5
+-- acpmFreqVHighTrapNum .2.12.12.4.1.6
+-- acpmFreqVHighClass .2.12.12.4.1.7
+-- acpmFreqHighValue .2.12.12.4.1.8
+-- acpmFreqHighActions .2.12.12.4.1.9
+-- acpmFreqHighTrapNum .2.12.12.4.1.10
+-- acpmFreqHighClass .2.12.12.4.1.11
+-- acpmFreqNormalActions .2.12.12.4.1.12
+-- acpmFreqNormalTrapNum .2.12.12.4.1.13
+-- acpmFreqNormalClass .2.12.12.4.1.14
+-- acpmFreqLowValue .2.12.12.4.1.15
+-- acpmFreqLowActions .2.12.12.4.1.16
+-- acpmFreqLowTrapNum .2.12.12.4.1.17
+-- acpmFreqLowClass .2.12.12.4.1.18
+-- acpmFreqVLowValue .2.12.12.4.1.19
+-- acpmFreqVLowActions .2.12.12.4.1.20
+-- acpmFreqVLowTrapNum .2.12.12.4.1.21
+-- acpmFreqVLowClass .2.12.12.4.1.22
+-- acpmFreqSysrepEnable .2.12.12.4.1.23
+-- acpmFreqSysrepThreshold .2.12.12.4.1.24
+-- acpmFreqSysrepLimit .2.12.12.4.1.25
+-- acpmTotalRealPowerTable .2.12.12.5
+-- acpmTRPEntry .2.12.12.5.1
+-- acpmTRPIndex .2.12.12.5.1.1
+-- acpmTRPEnable .2.12.12.5.1.2
+-- acpmTRPDeadband .2.12.12.5.1.3
+-- acpmTRPVHighValue .2.12.12.5.1.4
+-- acpmTRPVHighActions .2.12.12.5.1.5
+-- acpmTRPVHighTrapNum .2.12.12.5.1.6
+-- acpmTRPVHighClass .2.12.12.5.1.7
+-- acpmTRPHighValue .2.12.12.5.1.8
+-- acpmTRPHighActions .2.12.12.5.1.9
+-- acpmTRPHighTrapNum .2.12.12.5.1.10
+-- acpmTRPHighClass .2.12.12.5.1.11
+-- acpmTRPNormalActions .2.12.12.5.1.12
+-- acpmTRPNormalTrapNum .2.12.12.5.1.13
+-- acpmTRPNormalClass .2.12.12.5.1.14
+-- acpmTRPLowValue .2.12.12.5.1.15
+-- acpmTRPLowActions .2.12.12.5.1.16
+-- acpmTRPLowTrapNum .2.12.12.5.1.17
+-- acpmTRPLowClass .2.12.12.5.1.18
+-- acpmTRPVLowValue .2.12.12.5.1.19
+-- acpmTRPVLowActions .2.12.12.5.1.20
+-- acpmTRPVLowTrapNum .2.12.12.5.1.21
+-- acpmTRPVLowClass .2.12.12.5.1.22
+-- acpmTRPSysrepEnable .2.12.12.5.1.23
+-- acpmTRPSysrepThreshold .2.12.12.5.1.24
+-- acpmTRPSysrepLimit .2.12.12.5.1.25
+-- acpmDisconnectTable .2.12.12.6
+-- acpmDisconnectEntry .2.12.12.6.1
+-- acpmDisconnectIndex .2.12.12.6.1.1
+-- acpmDisconnectEnable .2.12.12.6.1.2
+-- acpmDisconnectActions .2.12.12.6.1.3
+-- acpmDisconnectTrapNum .2.12.12.6.1.4
+-- acpmDisconnectClass .2.12.12.6.1.5
+-- acpmDisconnectNormalActions .2.12.12.6.1.6
+-- acpmDisconnectNormalTrapNum .2.12.12.6.1.7
+-- acpmDisconnectNormalClass .2.12.12.6.1.8
+-- acpmTotalPowerFactorTable .2.12.12.7
+-- acpmTPFEntry .2.12.12.7.1
+-- acpmTPFIndex .2.12.12.7.1.1
+-- acpmTPFEnable .2.12.12.7.1.2
+-- acpmTPFDeadband .2.12.12.7.1.3
+-- acpmTPFNormalActions .2.12.12.7.1.4
+-- acpmTPFNormalTrapNum .2.12.12.7.1.5
+-- acpmTPFNormalClass .2.12.12.7.1.6
+-- acpmTPFLowValue .2.12.12.7.1.7
+-- acpmTPFLowActions .2.12.12.7.1.8
+-- acpmTPFLowTrapNum .2.12.12.7.1.9
+-- acpmTPFLowClass .2.12.12.7.1.10
+-- acpmTPFVLowValue .2.12.12.7.1.11
+-- acpmTPFVLowActions .2.12.12.7.1.12
+-- acpmTPFVLowTrapNum .2.12.12.7.1.13
+-- acpmTPFVLowClass .2.12.12.7.1.14
+-- acpmTPFSysrepEnable .2.12.12.7.1.15
+-- acpmTPFSysrepThreshold .2.12.12.7.1.16
+-- acpmTPFSysrepLimit .2.12.12.7.1.17
+-- evReset .2.12.16
+-- evResetEnable .2.12.16.1
+-- evResetDelay .2.12.16.2
+-- evResetActions .2.12.16.3
+-- evResetMessage .2.12.16.4
+-- evResetTrapnum .2.12.16.5
+-- evResetClass .2.12.16.6
+-- action .2.14
+-- actionCallNumberTable .2.14.1
+-- actionCallNumberEntry .2.14.1.1
+-- actionCallNumberIndex .2.14.1.1.1
+-- actionCallNumber .2.14.1.1.2
+-- actionPagerTable .2.14.2
+-- actionPagerEntry .2.14.2.1
+-- actionPagerIndex .2.14.2.1.1
+-- actionPagerType .2.14.2.1.2
+-- actionPagerNumber .2.14.2.1.3
+-- actionPagerID .2.14.2.1.4
+-- actionPagerMessage .2.14.2.1.5
+-- actionPagerPostCalloutDelay .2.14.2.1.6
+-- actionPagerPostIDDelay .2.14.2.1.7
+-- actionSched .2.14.3
+-- actionSchedEnable .2.14.3.1
+-- actionSchedBegin .2.14.3.2
+-- actionSchedEnd .2.14.3.3
+-- actionSchedWeekdaysOnly .2.14.3.4
+-- actionAsentria .2.14.4
+-- actionAsentriaRequireAck .2.14.4.1
+-- actionAsentriaVersion .2.14.4.2
+-- actionAsentriaTCPPort .2.14.4.3
+-- actionHostTable .2.14.6
+-- actionHostEntry .2.14.6.1
+-- actionHostIndex .2.14.6.1.1
+-- actionHost .2.14.6.1.2
+-- actionEmailTable .2.14.7
+-- actionEmailEntry .2.14.7.1
+-- actionEmailIndex .2.14.7.1.1
+-- actionEmail .2.14.7.1.2
+-- actionParseError .2.14.8
+-- sys .2.16
+-- sysTime .2.16.1
+-- sysTimeAutoDST .2.16.1.1
+-- sysTimeGMTOffset .2.16.1.2
+-- sysTimeGMTDirection .2.16.1.3
+-- sysTimeNet .2.16.1.4
+-- sysTimeNetEnable .2.16.1.4.1
+-- sysTimeNetHostTable .2.16.1.4.2
+-- sysTimeNetHostEntry .2.16.1.4.2.1
+-- sysTimeNetHostIndex .2.16.1.4.2.1.1
+-- sysTimeNetHost .2.16.1.4.2.1.2
+-- sysPT .2.16.2
+-- sysPTTimeout .2.16.2.1
+-- sysPTEndPause .2.16.2.2
+-- sysPTJoinable .2.16.2.3
+-- sysMTU .2.16.3
+-- sysAnswerString .2.16.4
+-- sysEventFileID .2.16.6
+-- sysEscapeCharacter .2.16.7
+-- sysTimeStamp .2.16.8
+-- sysTimeStampTimeFormat .2.16.8.1
+-- sysTimeStampDateFormat .2.16.8.2
+-- sysTimeStampSpaceAfter .2.16.8.3
+-- sysLog .2.16.9
+-- sysLogMode .2.16.9.1
+-- sysLoghost .2.16.9.2
+-- sysLogFilter .2.16.9.3
+-- sysLogFileSize .2.16.9.4
+-- sysLogFileCount .2.16.9.5
+-- sysLogListenPort .2.16.9.6
+-- sysCRDB .2.16.10
+-- sysCRDBCapacity .2.16.10.1
+-- sysCRDBPercentFull .2.16.10.2
+-- sysCRDBFileIDTable .2.16.10.3
+-- sysCRDBFileIDEntry .2.16.10.3.1
+-- sysCRDBFileIDIndex .2.16.10.3.1.1
+-- sysCRDBFileID .2.16.10.3.1.2
+-- sysCRDBFileEnforceMinTable .2.16.10.4
+-- sysCRDBFileEnforceMinEntry .2.16.10.4.1
+-- sysCRDBFileEnforceMinIndex .2.16.10.4.1.1
+-- sysCRDBFileEnforceMin .2.16.10.4.1.2
+-- sysCharMask .2.16.11
+-- sysPrompt .2.16.12
+-- sysBootStatus .2.16.13
+-- sysLoc .2.16.14
+-- sysLocLatitude .2.16.14.1
+-- sysLocLongitude .2.16.14.2
+-- sysLocXOffset .2.16.14.3
+-- sysLocYOffset .2.16.14.4
+-- sysLocAngle .2.16.14.5
+-- sysLocAltitude .2.16.14.6
+-- sysAssetMgmt .2.16.15
+-- sysAMManufacturer .2.16.15.1
+-- sysAMProduct .2.16.15.2
+-- sysAMSerialNumber .2.16.15.3
+-- sysAMHardwareOptions .2.16.15.4
+-- sysAMSoftwareVersion .2.16.15.5
+-- sysAMSiteName .2.16.15.6
+-- auditLog .2.17
+-- auditLogEnable .2.17.1
+-- auditLogStoreResets .2.17.2
+-- auditLogStoreCommands .2.17.3
+-- auditLogStoreOutputs .2.17.4
+-- auditLogStoreAlarmActions .2.17.5
+-- auditLogStorePwdFailures .2.17.6
+-- auditLogStoreLogins .2.17.7
+-- auditLogStoreSHSK .2.17.8
+-- auditLogStorePassthrough .2.17.9
+-- auditLogStoreInactivity .2.17.10
+-- auditLogStorePolling .2.17.11
+-- auditLogMaxSize .2.17.12
+
+-- productIds .3
+-- siteName 3.1
+-- thisProduct .3.2
+-- stockTrapString .3.3
+-- trapEventTypeNumber .3.4
+-- trapEventTypeName .3.5
+-- trapIncludedValue .3.6
+-- trapIncludedString .3.7
+-- trapTypeString .3.8
+-- trapEventClassNumber .3.9
+-- trapEventClassName .3.10
+
+-- keyInterface .4.0
+
+
+--***************************************************************************************
+--TOP-LEVEL OBJECT IDENTIFIERS
+--***************************************************************************************
+
+
+
+ status OBJECT IDENTIFIER ::= { s530 1 }
+ --1.3.6.1.4.1.3052.12.1
+
+ eventSensorStatus OBJECT IDENTIFIER ::= { status 1 }
+ --1.3.6.1.4.1.3052.12.1.1
+
+ dataEventStatus OBJECT IDENTIFIER ::= { status 2 }
+ --1.3.6.1.4.1.3052.12.1.2
+
+ powerDistributionStatus OBJECT IDENTIFIER ::= { status 5 }
+ --1.3.6.1.4.1.3052.12.1.5
+
+ pdNextGen OBJECT IDENTIFIER ::= { powerDistributionStatus 4 }
+ --1.3.6.1.4.1.3052.12.1.5.4
+
+ pdSystem OBJECT IDENTIFIER ::= { powerDistributionStatus 5 }
+ --1.3.6.1.4.1.3052.12.1.5.5
+
+ fuelSensorStatus OBJECT IDENTIFIER ::= { status 6 }
+ --1.3.6.1.4.1.3052.12.1.6
+
+ wirelessModemStatus OBJECT IDENTIFIER ::= { status 7 }
+ --1.3.6.1.4.1.3052.12.1.7
+
+ acPowerMonitorStatus OBJECT IDENTIFIER ::= { status 8 }
+ --1.3.6.1.4.1.3052.12.1.8
+
+ config OBJECT IDENTIFIER ::= { s530 2 }
+ --1.3.6.1.4.1.3052.12.2
+
+ eventSensorBasics OBJECT IDENTIFIER ::= { config 1 }
+ --1.3.6.1.4.1.3052.12.2.1
+
+ eventSensorPointConfig OBJECT IDENTIFIER ::= { config 2 }
+ --1.3.6.1.4.1.3052.12.2.2
+
+ serialPorts OBJECT IDENTIFIER ::= { config 3 }
+ --1.3.6.1.4.1.3052.12.2.3
+
+ network OBJECT IDENTIFIER ::= { config 4 }
+ --1.3.6.1.4.1.3052.12.2.4
+
+ interface OBJECT IDENTIFIER ::= { network 1 }
+ --1.3.6.1.4.1.3052.12.2.4
+
+ ethernet OBJECT IDENTIFIER ::= { interface 1 }
+ --1.3.6.1.4.1.3052.12.2.4.1
+
+ ethernet1 OBJECT IDENTIFIER ::= { ethernet 1 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1
+
+ ethernet2 OBJECT IDENTIFIER ::= { ethernet 2 }
+ --1.3.6.1.4.1.3052.12.2.4.1.2
+
+ snmp OBJECT IDENTIFIER ::= { network 8 }
+ --1.3.6.1.4.1.3052.12.2.4.8
+
+ snmpNotificationTx OBJECT IDENTIFIER ::= { snmp 7 }
+ --1.3.6.1.4.1.3052.12.2.4.8.7
+
+ ftpPush OBJECT IDENTIFIER ::= { network 9 }
+ --1.3.6.1.4.1.3052.12.2.4.9
+
+ ppp OBJECT IDENTIFIER ::= { network 10 }
+ --1.3.6.1.4.1.3052.12.2.4.10
+
+ pppDial OBJECT IDENTIFIER ::= { ppp 1 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1
+
+ pppHost OBJECT IDENTIFIER ::= { ppp 2 }
+ --1.3.6.1.4.1.3052.12.2.4.10.2
+
+ routing OBJECT IDENTIFIER ::= { network 11 }
+ --1.3.6.1.4.1.3052.12.2.4.11
+
+ netSecurity OBJECT IDENTIFIER ::= { network 12 }
+ --1.3.6.1.4.1.3052.12.2.4.12
+
+ ipRestriction OBJECT IDENTIFIER ::= { netSecurity 1 }
+ --1.3.6.1.4.1.3052.12.2.4.12.1
+
+ rts OBJECT IDENTIFIER ::= { network 13 }
+ --1.3.6.1.4.1.3052.12.2.4.13
+
+ rtsAlarms OBJECT IDENTIFIER ::= { rts 2 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2
+
+ trap OBJECT IDENTIFIER ::= { network 14 }
+ --1.3.6.1.4.1.3052.12.2.4.14
+
+ trapInclude OBJECT IDENTIFIER ::= { trap 1}
+ --1.3.6.1.4.1.3052.12.2.4.14.1
+
+ routeTest OBJECT IDENTIFIER ::= { network 15 }
+ --1.3.6.1.4.1.3052.12.2.4.15
+
+ wireless OBJECT IDENTIFIER ::= { network 16 }
+ --1.3.6.1.4.1.3052.12.2.4.16
+
+ wirelessConnectivity OBJECT IDENTIFIER ::= { wireless 20 }
+ --1.3.6.1.4.1.3052.12.2.4.16.20
+
+ email OBJECT IDENTIFIER ::= { network 17 }
+ --1.3.6.1.4.1.3052.12.2.4.17
+
+ netAdvanced OBJECT IDENTIFIER ::= { network 18 }
+ --1.3.6.1.4.1.3052.12.2.4.18
+
+ web OBJECT IDENTIFIER ::= { network 19 }
+ --1.3.6.1.4.1.3052.12.2.4.19
+
+ ethExpan OBJECT IDENTIFIER ::= { network 20 }
+ --1.3.6.1.4.1.3052.12.2.4.20
+
+ ethExpanDHCP OBJECT IDENTIFIER ::= { ethExpan 6 }
+ --1.3.6.1.4.1.3052.12.2.4.20.6
+
+ ipv6 OBJECT IDENTIFIER ::= { network 21 }
+ --1.3.6.1.4.1.3052.12.2.4.21
+
+ cpe OBJECT IDENTIFIER ::= { network 22 }
+ --1.3.6.1.4.1.3052.12.2.4.22
+
+ modem OBJECT IDENTIFIER ::= { config 5 }
+ --1.3.6.1.4.1.3052.12.2.5
+
+ modemClid OBJECT IDENTIFIER ::= { modem 8 }
+ --1.3.6.1.4.1.3052.12.2.5.7
+
+ time OBJECT IDENTIFIER ::= { config 8 }
+ --1.3.6.1.4.1.3052.12.2.8
+
+ console OBJECT IDENTIFIER ::= { config 10 }
+ --1.3.6.1.4.1.3052.12.2.10
+
+ unitSecurity OBJECT IDENTIFIER ::= { config 11 }
+ --1.3.6.1.4.1.3052.12.2.11
+
+ secCore OBJECT IDENTIFIER ::= { unitSecurity 1 }
+ --1.3.6.1.4.1.3052.12.2.11.1
+
+ secFactory OBJECT IDENTIFIER ::= { unitSecurity 3 }
+ --1.3.6.1.4.1.3052.12.2.11.3
+
+ secVPN OBJECT IDENTIFIER ::= { unitSecurity 5 }
+ --1.3.6.1.4.1.3052.12.2.11.5
+
+ event OBJECT IDENTIFIER ::= { config 12 }
+ --1.3.6.1.4.1.3052.12.2.12
+
+ evCore OBJECT IDENTIFIER ::= { event 1 }
+ --1.3.6.1.4.1.3052.12.2.12.1
+
+ evLog OBJECT IDENTIFIER ::= { evCore 3 }
+ --1.3.6.1.4.1.3052.12.2.12.1.3
+
+ evMgmt OBJECT IDENTIFIER ::= { evCore 4 }
+ --1.3.6.1.4.1.3052.12.2.12.1.4
+
+ evData OBJECT IDENTIFIER ::= { event 2 }
+ --1.3.6.1.4.1.3052.12.2.12.1
+
+ evdCore OBJECT IDENTIFIER ::= { evData 1 }
+ --1.3.6.1.4.1.3052.12.2.12.2.1
+
+ evNoData1 OBJECT IDENTIFIER ::= { event 3 }
+ --1.3.6.1.4.1.3052.12.2.12.1
+
+ evNoData2 OBJECT IDENTIFIER ::= { event 4 }
+ --1.3.6.1.4.1.3052.12.2.12.1
+
+ evSched1 OBJECT IDENTIFIER ::= { event 5 }
+ --1.3.6.1.4.1.3052.12.2.12.1
+
+ evSched2 OBJECT IDENTIFIER ::= { event 6 }
+ --1.3.6.1.4.1.3052.12.2.12.1
+
+ evNoSensor OBJECT IDENTIFIER ::= { event 9 }
+ --1.3.6.1.4.1.3052.12.2.12.1
+
+ fuelSensor OBJECT IDENTIFIER ::= { event 11 }
+ --1.3.6.1.4.1.3052.12.2.12.11
+
+ acPowerMonitor OBJECT IDENTIFIER ::= { event 12 }
+ --1.3.6.1.4.1.3052.12.2.12.12
+
+ evReset OBJECT IDENTIFIER ::= { event 16 }
+ --1.3.6.1.4.1.3052.12.2.12.16
+
+ action OBJECT IDENTIFIER ::= { config 14 }
+ --1.3.6.1.4.1.3052.12.2.14
+
+ actionSched OBJECT IDENTIFIER ::= { action 3 }
+ --1.3.6.1.4.1.3052.12.2.14.3
+
+ actionAsentria OBJECT IDENTIFIER ::= { action 4 }
+ --1.3.6.1.4.1.3052.12.2.14.4
+
+ sys OBJECT IDENTIFIER ::= { config 16 }
+ --1.3.6.1.4.1.3052.12.2.16
+
+ sysTime OBJECT IDENTIFIER ::= { sys 1 }
+ --1.3.6.1.4.1.3052.12.2.16.1
+
+ sysTimeNet OBJECT IDENTIFIER ::= { sysTime 4 }
+ --1.3.6.1.4.1.3052.12.2.16.1.4
+
+ sysPT OBJECT IDENTIFIER ::= { sys 2 }
+ --1.3.6.1.4.1.3052.12.2.16.2
+
+ sysTimeStamp OBJECT IDENTIFIER ::= { sys 8 }
+ --1.3.6.1.4.1.3052.12.2.16.8
+
+ sysLog OBJECT IDENTIFIER ::= { sys 9 }
+ --1.3.6.1.4.1.3052.12.2.16.9
+
+ sysCRDB OBJECT IDENTIFIER ::= { sys 10 }
+ --1.3.6.1.4.1.3052.12.2.16.10
+
+ sysLoc OBJECT IDENTIFIER ::= { sys 14 }
+ --1.3.6.1.4.1.3052.12.2.16.14
+
+ sysAssetMgmt OBJECT IDENTIFIER ::= { sys 15 }
+ --1.3.6.1.4.1.3052.12.2.16.14
+
+ auditLog OBJECT IDENTIFIER ::= { config 17 }
+ --1.3.6.1.4.1.3052.12.2.17
+
+ productIds OBJECT IDENTIFIER ::= { s530 3 }
+ --1.3.6.1.4.1.3052.12.3
+
+--***************************************************************************************
+--OBJECT DEFINITIONS
+--***************************************************************************************
+
+--***************************************************************************************
+--EventSensor Status Section 1.1
+--***************************************************************************************
+
+esPointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "
+ This table organizes 4 basic attributes of points. A point
+ is a particular sensor on an EventSensor (e.g., temperature,
+ humidity, contact closure 2, output 5, etc.). The 4 point
+ attributes are its name, whether it's in its event state,
+ the point's value as a number and its value as a string.
+
+ Points are referenced by a point index. The point index
+ is a string of 3 numbers separated by periods.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor; namely, which EventSensor,
+ point class, and which-sensor-of-that-class (a.k.a. point).
+ "
+ ::= { eventSensorStatus 1 }
+ --1.3.6.1.4.1.3052.12.1.1.1
+
+esPointEntry OBJECT-TYPE
+ SYNTAX ESPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point table"
+ INDEX { esIndexES, esIndexPC, esIndexPoint }
+ ::= { esPointTable 1 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1
+
+esIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point index is a string of 3 numbers separated
+ by periods. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor; namely, which EventSensor, point class,
+ and which-sensor-of-that-class (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndexES=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esPointEntry 1 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.1
+
+esIndexPC OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to point class.
+
+ The point index is a string of 3 numbers separated by periods.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor; namely, which EventSensor,
+ point class, and which-sensor-of-that-class (a.k.a. point).
+
+ The values for this object are:
+ 1=temperature sensor
+ 2=contact closure
+ 3=humidity sensor
+ 4=noise sensor
+ 5=analog input
+ 6=output (relay output or power output)
+ "
+ ::= { esPointEntry 2 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.2
+
+esIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with esIndexPC (Point Class or type)
+ and esIndexES (which EventSensor) uniquely defines each
+ point (sensor or output) attached to a unit. For
+ example, if esIndexES is 3, esIndexPC is 1 and
+ esIndexPoint is 4 then this is the Fourth Temperature
+ Sensor on EventSensor number 3."
+ ::= { esPointEntry 3 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.3
+
+esPointName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the point on an EventSensor. For example,
+ 'AC temp' (in the case of the temperature sensor on an
+ EventSensor).
+
+ There can be multiple points of the same point class on an
+ EventSensor (e.g., 8 contact closures) and multiple sensor
+ classes on an EventSensor (e.g., temperature, contact closure,
+ humidity).
+
+ If the point referenced by a given point index is solitary
+ (e.g., temperature sensor, because there can be only one on
+ an EventSensor), then this object reads as '<EventSensor
+ name>'. Setting this object for solitary point indices sets
+ the EventSensor name only.
+
+ On the other hand, if a given point is among other points of
+ the same point class on an EventSensor, then this object reads
+ as '<Sensor name>'. Setting this object for these NON-
+ solitary point indices sets the sensor name only - not the
+ EventSensor name."
+ ::= { esPointEntry 4 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.4
+
+esPointInEventState OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A number referring to the event state of a point
+ on an EventSensor. This number can have different
+ meanings depending on the point class.
+
+ If the point class is temperature, humidity, or
+ analog input, then the values of this object are:
+ 1=very low
+ 2=low
+ 3=normal
+ 4=high
+ 5=very high
+
+ For contact closures the values of this object are:
+ 1=point in event state
+ 2=point in normal state
+
+ For outputs the values of this object is the numeric
+ code for the logical state of the output: 1 or 2. The
+ logical state of the output is either active/inactive for
+ relay outputs or on/off for power outputs. The logical
+ state of the output has different nomenclature depending
+ on the type of the output (relay output or power output):
+
+ 1=active (for relay output) or on (for power output)
+ 2=inactive (for relay output) or off (for power output)
+
+ This is not necessarily representative of physical state
+ of the output. Physical state is energized/de-energized,
+ for both relay and power outputs. For relay outputs,
+ the active logical state corresponds to either the energized
+ physical state or the de-energized physical state depending
+ on how the relay output is configured. For power outputs,
+ the on logical state always corresponds to the energized
+ physical state.
+
+ For any point class and any point, if the event
+ state is undefined, then the value of this object
+ is 0.
+
+ For any point class except output, this object is read-only.
+ For outputs, setting this object to 1 puts the output into
+ its active logical state.
+
+ Setting this object to 2 puts the output into its inactive
+ logical state.
+
+ Setting this object to any value greater than 2 puts the
+ output into its active logical state for that many seconds
+ (up to 3600), after which time it puts the output into its
+ inactive logical state.
+ "
+ ::= { esPointEntry 5 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.5
+
+esPointValueInt OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A read-only number referring to the value of a
+ point on an EventSensor.
+
+ If the point class is temperature, then this object
+ is the temperature in its configured scale (default
+ is Fahrenheit).
+
+ If the point class is contact closure, then
+ this object is either 0 (open) or 1 (closed).
+
+ If the point class is humidity, then this object
+ is the percent relative humidity.
+
+ If the point class is analog input, then this
+ object is the signed input value in tenths of the
+ configured units.
+
+ If the point class is an output, then this object is
+ the numeric code for the physical state of the output.
+ 0=de-energized
+ 1=energized
+
+ This object cannot be used to control the output, i.e,
+ change its logical or physical state (instead use
+ the esPointInEventState object).
+ "
+ ::= { esPointEntry 6 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.6
+
+esPointValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string referring to the value of a point on an
+ EventSensor.
+
+ For contact closures this object is either 'Open'
+ or 'Closed'.
+
+ For outputs this object is a concatenation of the
+ logical state and physical state, separated by '/'.
+
+ For a relay output this object can be one of the
+ following 4 possible values:
+
+ Active/Energized
+ Inactive/Energized
+ Active/De-energized
+ Inactve/De-energized
+
+ For a power output this object can be one of the
+ following 2 possible values:
+
+ On/Energized
+ Off/De-energized
+
+ For temperature and humidity point classes, this
+ object is the string representation of the
+ esPointValueInt object. For temperature, 'C' or
+ 'F' is including in the string to indicate scale.
+
+ For analog inputs, this object is the string
+ representation of the plus/minus input in the
+ configured units appended with the unit name.
+ "
+ ::= { esPointEntry 7 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.7
+
+esPointTimeLastChange OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last time an event was
+ triggerred for a point on an EventSensor in
+ MM/DD/YY HH:MM:SS format.
+
+ For contact closures, the possible events are
+ Active and Inactive. For temperature, humidity,
+ and analog inputs, the possible events are Normal,
+ High, Very High, Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { esPointEntry 8 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.8
+
+esPointTimetickLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last time an event was
+ triggerred for a point on an EventSensor in
+ 100ths of seconds since reset.
+
+ For contact closures, the possible events are
+ Active and Inactive. For temperature, humidity,
+ and analog inputs, the possible events are Normal,
+ High, Very High, Low, and Very Low.
+
+ For outputs, this object is 0."
+ ::= { esPointEntry 9 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.9
+
+esPointAliasValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For CC inputs, this is the CC active/inactive alias setting
+ setting value that currently corresponds to the event state.
+ So if the CC input is in the event state, then this object
+ is the active alias setting value. If the CC input is in the
+ normal state, then this object is the inactive alias setting
+ value.
+
+ For relay/power outputs, this is the output active/inactive
+ alias setting value that currently corresponds to the output
+ state. So if the output is in the active state, then this
+ object is the active alias setting value. If the output is
+ in hte inactive state, then this object is the inactive alias
+ setting value.
+
+ For non-CC and non-output sensors, this is the same as the
+ esPointValueStr object."
+ ::= { esPointEntry 10 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.10
+
+
+esPointClassValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For CC inputs, this is the CC active/inactive class setting
+ setting value that currently corresponds to the event state.
+ So if the CC input is in the event state, then this object
+ is the active class setting value. If the CC input is in the
+ normal state, then this object is the inactive class setting
+ value.
+
+ For relay/power, analog and temp outputs, this is the output
+ class string given the event (Very High, High, Normal, Low and
+ Very Low). The class string is based upon the chosen string in
+ the class table for e.g. Info, Minor, Major, Minor, Critical etc.
+ If the given event is High, the chosen Class string for this event
+ is what returned.
+ "
+ ::= { esPointEntry 11 }
+ --1.3.6.1.4.1.3052.12.1.1.1.1.11
+--***************************************************************************************
+--Data Event Status Section 1.2
+--***************************************************************************************
+
+deStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DEStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Data Event Status Table"
+ ::= { dataEventStatus 1 }
+ --1.3.6.1.4.1.3052.12.1.2.1
+
+deStatusEntry OBJECT-TYPE
+ SYNTAX DEStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "EventSensor status entry"
+ INDEX { deStatusIndex }
+ ::= { deStatusTable 1 }
+ --1.3.6.1.4.1.3052.12.1.2.1.1
+
+deStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Data Events"
+ ::= { deStatusEntry 1 }
+ --1.3.6.1.4.1.3052.12.1.2.1.1.1
+
+deStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Data Event name"
+ ::= { deStatusEntry 2 }
+ --1.3.6.1.4.1.3052.12.1.2.1.1.2
+
+deStatusCounter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times a data record has matched this
+ event's equation.
+ Range: 1-999999999"
+ ::= { deStatusEntry 3 }
+ --1.3.6.1.4.1.3052.12.1.2.1.1.3
+
+deStatusThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times the equation is matched before
+ an event is triggered.
+ Range: 1-999999999"
+ ::= { deStatusEntry 4 }
+ --1.3.6.1.4.1.3052.12.1.2.1.1.4
+
+modemStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status of modem (idle, dialing, connected, etc.)"
+ ::= { status 3 }
+ --1.3.6.1.4.1.3052.12.1.3
+
+modemCLIDLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ModemCLIDLogConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of numbers of recent dialing parties"
+ ::= { status 4 }
+ --1.3.6.1.4.1.3052.12.1.4
+
+modemCLIDLogEntry OBJECT-TYPE
+ SYNTAX ModemCLIDLogConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CLID log entries"
+ INDEX { modemCLIDLogIndex }
+ ::= { modemCLIDLogTable 1 }
+ --1.3.6.1.4.1.3052.12.1.4.1
+
+modemCLIDLogIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CLID log entries"
+ ::= { modemCLIDLogEntry 1 }
+ --1.3.6.1.4.1.3052.12.1.4.1.1
+
+modemCLIDLogNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "recently logged number of dialing party"
+ ::= { modemCLIDLogEntry 2 }
+ --1.3.6.1.4.1.3052.12.1.4.1.2
+
+--***************************************************************************************
+--Power Distribution Status Section 1.5
+--***************************************************************************************
+
+pdConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution output configuration"
+ ::= { powerDistributionStatus 1 }
+ --1.3.6.1.4.1.3052.12.1.5.1
+
+PowerDistribNextGen ::=
+ SEQUENCE {
+ pdnIndexPD
+ Integer32,
+ pdnIndexOutput
+ Integer32,
+ pdnConfig
+ DisplayString,
+ pdnMainCurrentInEventState
+ DisplayString,
+ pdnMainCurrentValue
+ Integer32,
+ pdnMainCurrentValueStr
+ DisplayString,
+ pdnMainCurrentDeadband
+ Integer32,
+ pdnMainCurrentVHighCurrent
+ Integer32,
+ pdnMainCurrentHighCurrent
+ Integer32,
+ pdnMainCurrentLowCurrent
+ Integer32,
+ pdnMainCurrentVLowCurrent
+ Integer32,
+ pdnMainVoltageInEventState
+ DisplayString,
+ pdnMainVoltageValue
+ Integer32,
+ pdnMainVoltageValueStr
+ DisplayString,
+ pdnMainVoltageDeadband
+ Integer32,
+ pdnMainVoltageVHighVoltage
+ Integer32,
+ pdnMainVoltageHighVoltage
+ Integer32,
+ pdnMainVoltageLowVoltage
+ Integer32,
+ pdnMainVoltageVLowVoltage
+ Integer32,
+ pdnMainPowerValue
+ Integer32,
+ pdnMainPowerValueStr
+ DisplayString,
+ pdnOutputCurrentInEventState
+ DisplayString,
+ pdnOutputCurrentValue
+ Integer32,
+ pdnOutputCurrentValueStr
+ DisplayString,
+ pdnOutputCurrentDeadband
+ Integer32,
+ pdnOutputCurrentVHighCurrent
+ Integer32,
+ pdnOutputCurrentHighCurrent
+ Integer32,
+ pdnOutputCurrentLowCurrent
+ Integer32,
+ pdnOutputCurrentVLowCurrent
+ Integer32,
+ pdnOutputFuseInEventState
+ DisplayString,
+ pdnOutputFuseValueStr
+ DisplayString,
+ pdnMainCombinedStatus
+ DisplayString,
+ pdnOutputCombinedStatusBlock1
+ DisplayString,
+ pdnOutputCombinedStatusBlock2
+ DisplayString,
+ pdnDeviceCurrentValue
+ Integer32,
+ pdnDeviceCurrentValueStr
+ DisplayString
+}
+
+pdnTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerDistribNextGen
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of power distribution objects arranged according
+ to next-generation methodology (i.e., using multiple PowerBoss
+ power distributors in addition to the on-board power
+ distributor)."
+ ::= { pdNextGen 1 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1
+
+pdnEntry OBJECT-TYPE
+ SYNTAX PowerDistribNextGen
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of power distribution objects arranged according
+ to next-generation methodology (i.e., using multiple PowerBoss
+ power distributors in addition to the on-board power
+ distributor)."
+ INDEX { pdnIndexPD, pdnIndexOutput }
+ ::= { pdnTable 1 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1
+
+pdnIndexPD OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power distribution objects, specifically the
+ index that refers to which power distributor. A value of 200 means
+ the internal power distributor. A value from 1 to 16 refers to an
+ external power distributor (PowerBoss), and is the same value as esIndexES,
+ which refers to the PowerBoss as an EventSensor in the eventSensorStatus
+ object table. In other words, pdnIndexPD is the same as esIndexES:
+ esIndexES is used to refer to the PowerBoss as an eventsensor (i.e., control
+ outputs), while pdnIndexPD is used to refer to the PowerBoss when used for
+ power distribution monitoring (i.e., to alarm on output
+ current/voltage/fuse status)."
+ ::= { pdnEntry 1 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.1
+
+pdnIndexOutput OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power distribution objects, specifically the
+ index that refers to which output on the power distributor specified
+ by pdnIndexPD. For objects where the output is irrelevant, this index
+ should be 1."
+ ::= { pdnEntry 2 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.2
+
+pdnConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs on the power distributor specified by pdnIndexPD.
+ pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 3 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.3
+
+pdnMainCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the current (i.e. Amps) event of the power distributor
+ specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
+ Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
+ 'Very High'."
+ ::= { pdnEntry 4 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.4
+
+pdnMainCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current drawn, in mA, for the power distributor specified by pdnIndexPD.
+ If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss)
+ and refers to the current drawn by that PowerBoss and all equipment powered
+ by that PowerBoss. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 5 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.5
+
+pdnMainCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnMainCurrentValue formatted as a string in units of Amps, with
+ 3 decimal places. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 6 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.6
+
+pdnMainCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mA, for the main current sensor for the power distributor
+ specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 7 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.7
+
+pdnMainCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Very High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 8 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.8
+
+pdnMainCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 9 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.9
+
+pdnMainCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 10 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.10
+
+pdnMainCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Very Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 11 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.11
+
+pdnMainVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the voltage event of the power distributor
+ specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
+ Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
+ 'Very High'."
+ ::= { pdnEntry 12 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.12
+
+pdnMainVoltageValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, at the power distributor specified by pdnIndexPD.
+ If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and
+ refers to the voltage at that PowerBoss and all equipment powered by that
+ PowerBoss. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 13 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.13
+
+pdnMainVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnMainVoltageValue formatted as a string in units of Volts, with
+ 3 decimal places. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 14 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.14
+
+pdnMainVoltageDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mV, for the main voltage sensor for the power distributor
+ specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 15 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.15
+
+pdnMainVoltageVHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mA, for the main voltage sensor's Very High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 16 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.16
+
+pdnMainVoltageHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 17 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.17
+
+pdnMainVoltageLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 18 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.18
+
+pdnMainVoltageVLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's Very Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 19 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.19
+
+pdnMainPowerValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power, in Watts, for the power distributor specified by pdIndexPD.
+ pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 20 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.20
+
+pdnMainPowerValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power, in Watts, for the power distributor specified by pdIndexPD,
+ formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 21 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.21
+
+pdnOutputCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the current (i.e. Amps) event of the power distributor
+ output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200
+ and pdnIndexOutput=2, this refers to power output #2 of the internal power
+ distributor. Possible values for this object are: 'Very Low', 'Low', 'Normal',
+ 'High', 'Very High'."
+ ::= { pdnEntry 22 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.22
+
+pdnOutputCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current drawn, in mA, for the power distributor output specified by
+ pdnIndexPD and pdIndexOutput. E.g., if pdIndexPD is 3 then this is an external
+ power distributor (PowerBoss) identified as 'power distributor 3' and refers to
+ the current drawn by a specific power output on that PowerBoss. The specific
+ power output is specified by pdIndexOutput."
+ ::= { pdnEntry 23 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.23
+
+pdnOutputCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnOutputCurrentValue formatted as a string in units of Amps, with
+ 3 decimal places."
+ ::= { pdnEntry 24 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.24
+
+pdnOutputCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mA, for the main current sensor for the power distributor
+ specified by pdIndexPD. The power output is specified by pdnIndexOutput."
+ ::= { pdnEntry 25 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.25
+
+pdnOutputCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Very High
+ event threshold, for the power distributor specified by pdIndexPD. The power
+ output is specified by pdnIndexOutput."
+ ::= { pdnEntry 26 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.26
+
+pdnOutputCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor High event
+ threshold, for the power distributor specified by pdIndexPD. The power output
+ is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 27 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.27
+
+pdnOutputCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Low event
+ threshold, for the power distributor specified by pdIndexPD. The power output
+ is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 28 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.28
+
+pdnOutputCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Very Low
+ event threshold, for the power distributor specified by pdIndexPD. The power
+ output is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 29 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.29
+
+pdnOutputFuseInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the fuse event of the power distributor output specified
+ by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2,
+ this refers to power output #2 of the external power distributor (PowerBoss),
+ identified as 'power distributor 14'. Possible values for this object are:
+ 'Very Low', 'Low', 'Normal', 'High', 'Very High'. This object exists only for
+ power distributors with fuse monitoring support."
+ ::= { pdnEntry 30 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.30
+
+pdnOutputFuseValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the fuse of the power distributor output specified
+ by pdnIndexPD and pdnIndexOutput. Possible values for this object are:
+ 'BLOWN' and 'OK'. This object exists only for power distributors with
+ fuse monitoring support."
+ ::= { pdnEntry 31 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.31
+
+pdnMainCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValue"
+ ::= { pdnEntry 32 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.32
+
+pdnOutputCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
+ ::= { pdnEntry 33 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.33
+
+pdnOutputCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
+ ::= { pdnEntry 34 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.34
+
+pdnDeviceCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current drawn by device in mA. For the internal power distributor device,
+ this is the current drawn by the SiteBoss 571. For an external power
+ distributor device (PowerBoss), this is the current drawn by the
+ PowerBoss. This object exists only for power distributors with device
+ current monitoring support."
+ ::= { pdnEntry 35 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.35
+
+pdnDeviceCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current drawn by device as a string with units (Amps). For the internal
+ power distributor device, this is the current drawn by the SiteBoss 571.
+ For an external power distributor device (PowerBoss), this is the
+ current drawn by the PowerBoss. This object exists only for power
+ distributors with device current monitoring support."
+ ::= { pdnEntry 36 }
+ --1.3.6.1.4.1.3052.12.1.5.4.1.1.36
+
+pdSystemCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total current drawn by all power distributors in system; that is, the
+ sum of all pdnMainCurrentValue objects for all connected power
+ distributors: internal and external."
+ ::= { pdSystem 1 }
+ --1.3.6.1.4.1.3052.12.1.5.5.1
+
+pdSystemPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power used by all power distributors in system; that is, the
+ sum of all pdnMainPowerValue objects for all connected power
+ distributors: internal and external."
+ ::= { pdSystem 2 }
+ --1.3.6.1.4.1.3052.12.1.5.5.2
+
+
+--***************************************************************************************
+--Fuel Sensor 1.6
+--***************************************************************************************
+
+fsStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FSStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor status table"
+ ::= { fuelSensorStatus 1 }
+ --1.3.6.1.4.1.3052.12.1.6.1
+
+fsStatusEntry OBJECT-TYPE
+ SYNTAX FSStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor status table entry"
+ INDEX { fsStatusIndex }
+ ::= { fsStatusTable 1 }
+ --1.3.6.1.4.1.3052.12.1.6.1.1
+
+fsStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for fuel sensors"
+ ::= { fsStatusEntry 1 }
+ --1.3.6.1.4.1.3052.12.1.6.1.1.1
+
+fsStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor name"
+ ::= { fsStatusEntry 2 }
+ --1.3.6.1.4.1.3052.12.1.6.1.1.2
+
+fsStatusDeviceState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor device state"
+ ::= { fsStatusEntry 3 }
+ --1.3.6.1.4.1.3052.12.1.6.1.1.3
+
+fsStatusVolumeValueString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads
+ -999 when the fuel sensor is disconnected"
+ ::= { fsStatusEntry 4 }
+ --1.3.6.1.4.1.3052.12.1.6.1.1.4
+
+fsStatusVolumePercentLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Height of the fluid in the tank expressed as a percentage of the tank
+ height, in hundredths of a percent."
+ ::= { fsStatusEntry 7 }
+ --1.3.6.1.4.1.3052.12.1.6.1.1.7
+
+fsStatusVolumeInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current event status of the fuel sensor."
+ ::= { fsStatusEntry 8 }
+ --1.3.6.1.4.1.3052.12.1.6.1.1.8
+
+fsStatusCombined OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`name"
+ ::= { fsStatusEntry 9 }
+ --1.3.6.1.4.1.3052.12.1.6.1.1.9
+
+--***************************************************************************************
+--Wireless Modem Status Section 1.7
+--***************************************************************************************
+
+wmsStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem status"
+ ::= { wirelessModemStatus 1 }
+ --1.3.6.1.4.1.3052.12.1.7.1
+
+wmsSignal OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Signal strength"
+ ::= { wirelessModemStatus 2 }
+ --1.3.6.1.4.1.3052.12.1.7.2
+
+wmsRSSI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Signal strength (RSSI)"
+ ::= { wirelessModemStatus 3 }
+ --1.3.6.1.4.1.3052.12.1.7.3
+
+wmsBER OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Bit Error Rate"
+ ::= { wirelessModemStatus 4 }
+ --1.3.6.1.4.1.3052.12.1.7.4
+
+wmsUpdated OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem info last update time"
+ ::= { wirelessModemStatus 5 }
+ --1.3.6.1.4.1.3052.12.1.7.5
+
+wmsRegistration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem registration status"
+ ::= { wirelessModemStatus 6 }
+ --1.3.6.1.4.1.3052.12.1.7.6
+
+wmsLAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Location Area Code"
+ ::= { wirelessModemStatus 7 }
+ --1.3.6.1.4.1.3052.12.1.7.7
+
+wmsCellID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Cell ID"
+ ::= { wirelessModemStatus 8 }
+ --1.3.6.1.4.1.3052.12.1.7.8
+
+wmsIMSI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Internation Mobile Subscriber Identity number"
+ ::= { wirelessModemStatus 9 }
+ --1.3.6.1.4.1.3052.12.1.7.9
+
+wmsPhnum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem phone number"
+ ::= { wirelessModemStatus 10 }
+ --1.3.6.1.4.1.3052.12.1.7.10
+
+wmsLocalIP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Local IP address of modem on wireless network"
+ ::= { wirelessModemStatus 11 }
+ --1.3.6.1.4.1.3052.12.1.7.11
+
+wmsMgfID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem manufacturer ID"
+ ::= { wirelessModemStatus 12 }
+ --1.3.6.1.4.1.3052.12.1.7.12
+
+wmsModelID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem model ID"
+ ::= { wirelessModemStatus 13 }
+ --1.3.6.1.4.1.3052.12.1.7.13
+
+wmsIMEI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem International Mobile Equipment Identity number"
+ ::= { wirelessModemStatus 14 }
+ --1.3.6.1.4.1.3052.12.1.7.14
+
+wmsRevID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem revision ID"
+ ::= { wirelessModemStatus 15 }
+ --1.3.6.1.4.1.3052.12.1.7.15
+
+wmsNetName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem network name"
+ ::= { wirelessModemStatus 16 }
+ --1.3.6.1.4.1.3052.12.1.7.16
+
+wmsGPRSStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem (E)GPRS status"
+ ::= { wirelessModemStatus 17 }
+ --1.3.6.1.4.1.3052.12.1.7.17
+
+wmsBand OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem band"
+ ::= { wirelessModemStatus 18 }
+ --1.3.6.1.4.1.3052.12.1.7.18
+
+wmsChannel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem channel"
+ ::= { wirelessModemStatus 19 }
+ --1.3.6.1.4.1.3052.12.1.7.19
+
+wmsCountryCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem country code"
+ ::= { wirelessModemStatus 20 }
+ --1.3.6.1.4.1.3052.12.1.7.20
+
+wmsNetCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem network code"
+ ::= { wirelessModemStatus 21 }
+ --1.3.6.1.4.1.3052.12.1.7.21
+
+wmsPLMNColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem PLMN color"
+ ::= { wirelessModemStatus 22 }
+ --1.3.6.1.4.1.3052.12.1.7.22
+
+wmsBScolor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem BS color"
+ ::= { wirelessModemStatus 23 }
+ --1.3.6.1.4.1.3052.12.1.7.23
+
+wmsMpRACH OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem max power RACH"
+ ::= { wirelessModemStatus 24 }
+ --1.3.6.1.4.1.3052.12.1.7.24
+
+wmsMinRxLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem minimum receive level"
+ ::= { wirelessModemStatus 25 }
+ --1.3.6.1.4.1.3052.12.1.7.25
+
+wmsBaseCoeff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem base coefficient"
+ ::= { wirelessModemStatus 26 }
+ --1.3.6.1.4.1.3052.12.1.7.26
+
+wmsSIMStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "WWireless modem SIM status"
+ ::= { wirelessModemStatus 27 }
+ --1.3.6.1.4.1.3052.12.1.7.27
+
+wmsICCID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem SIM ICCID"
+ ::= { wirelessModemStatus 28 }
+ --1.3.6.1.4.1.3052.12.1.7.28
+
+wmsModemType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem type"
+ ::= { wirelessModemStatus 29 }
+ --1.3.6.1.4.1.3052.12.1.7.29
+
+
+--***************************************************************************************
+--AC Power Monitor Section 1.8
+--***************************************************************************************
+
+acpmStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "AC power monitor status table"
+ ::= { acPowerMonitorStatus 1 }
+ --1.3.6.1.4.1.3052.12.1.8.1
+
+acpmStatusEntry OBJECT-TYPE
+ SYNTAX ACPMStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "AC power monitor status table entry"
+ INDEX { acpmsIndex }
+ ::= { acpmStatusTable 1 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1
+
+acpmsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AC power monitors"
+ ::= { acpmStatusEntry 1 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.1
+
+acpmsName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name for the AC power monitor device."
+ ::= { acpmStatusEntry 2 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.2
+
+acpmsAvgVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1). This could be either the average of
+ the phase voltages, or the sum of the phase voltages, depending
+ on device configuration."
+ ::= { acpmStatusEntry 3 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.3
+
+acpmsAvgVoltageMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum average voltage value since last reset, in volts."
+ ::= { acpmStatusEntry 4 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.4
+
+acpmsAvgVoltageMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum average voltage value since last reset, in volts."
+ ::= { acpmStatusEntry 5 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.5
+
+acpmsAvgVoltageAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average average voltage value since last reset, in volts. This is
+ the unit's average of its measurements of the average voltage
+ reported by the AC power monitor device."
+ ::= { acpmStatusEntry 6 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.6
+
+acpmsAvgVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor voltage (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 7 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.7
+
+acpmsVoltagePhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 8 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.8
+
+acpmsVoltagePhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 9 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.9
+
+acpmsVoltagePhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 10 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.10
+
+acpmsAvgCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001). This could be either the average of
+ the phase currents, or the sum of the phase currents, depending on
+ device configuration."
+ ::= { acpmStatusEntry 11 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.11
+
+acpmsAvgCurrentMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum average current value since last reset, in amps."
+ ::= { acpmStatusEntry 12 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.12
+
+acpmsAvgCurrentMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum average current value since last reset, in amps."
+ ::= { acpmStatusEntry 13 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.13
+
+acpmsAvgCurrentAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average average current value since last reset, in amps. This is
+ the unit's average of its measurements of the average current reported
+ by the AC power monitor device."
+ ::= { acpmStatusEntry 14 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.14
+
+acpmsAvgCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor current (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 15 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.15
+
+acpmsCurrentPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 16 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.16
+
+acpmsCurrentPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 17 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.17
+
+acpmsCurrentPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 18 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.18
+
+acpmsAvgFreqValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency, in hertz. On the YD2010, this is calculated using the
+ formula (register * 0.00106813). On the WattsOn, this is calculated
+ using the formula (register * 0.1)."
+ ::= { acpmStatusEntry 19 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.19
+
+acpmsAvgFreqMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum frequency value since last reset, in hertz."
+ ::= { acpmStatusEntry 20 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.20
+
+acpmsAvgFreqMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum frequency value since last reset, in hertz."
+ ::= { acpmStatusEntry 21 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.21
+
+acpmsAvgFreqAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average frequency value since last reset, in hertz. This is the
+ unit's average of its measurements of the average frequency reported
+ by the AC power monitor device."
+ ::= { acpmStatusEntry 22 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.22
+
+acpmsAvgFreqInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor frequency (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 23 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.23
+
+acpmsTRPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn models,
+ this is calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 24 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.24
+
+acpmsTRPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum total real power value since last reset, in watts."
+ ::= { acpmStatusEntry 25 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.25
+
+acpmsTRPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum total real power value since last reset, in watts."
+ ::= { acpmStatusEntry 26 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.26
+
+acpmsTRPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average total real power value since last reset, in watts. This is
+ the unit's average of its measurements of the average total real power
+ reported by the AC power monitor device."
+ ::= { acpmStatusEntry 27 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.27
+
+acpmsTRPInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor total real power (Low, Normal,
+ High, etc.)."
+ ::= { acpmStatusEntry 28 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.28
+
+acpmsRPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 29 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.29
+
+acpmsRPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 30 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.30
+
+acpmsRPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 31 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.31
+
+acpmsCombined OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`freuencyColorCode`powerEventState`powerColorCode"
+ ::= { acpmStatusEntry 32 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.32
+
+acpmsTPFValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor."
+ ::= { acpmStatusEntry 33 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.33
+
+acpmsTPFMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor minimum value since last reset."
+ ::= { acpmStatusEntry 34 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.34
+
+acpmsTPFMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor maximum value since last reset."
+ ::= { acpmStatusEntry 35 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.35
+
+acpmsTPFAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor average value since last reset."
+ ::= { acpmStatusEntry 36 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.36
+
+acpmsTPFInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor event state."
+ ::= { acpmStatusEntry 37 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.37
+
+acpmsPFPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A power factor."
+ ::= { acpmStatusEntry 38 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.38
+
+acpmsPFPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B power factor."
+ ::= { acpmStatusEntry 39 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.39
+
+acpmsPFPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C power factor."
+ ::= { acpmStatusEntry 40 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.40
+
+acpmsTRcPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power, in VAR."
+ ::= { acpmStatusEntry 41 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.41
+
+acpmsTRcPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power minimum value since last reset, in VAR."
+ ::= { acpmStatusEntry 42 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.42
+
+acpmsTRcPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power maximum value since last reset, in VAR."
+ ::= { acpmStatusEntry 43 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.43
+
+acpmsTRcPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power average value since last reset, in VAR."
+ ::= { acpmStatusEntry 44 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.44
+
+acpmsRcPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A reactive power, in VAR."
+ ::= { acpmStatusEntry 45 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.45
+
+acpmsRcPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B reactive power, in VAR."
+ ::= { acpmStatusEntry 46 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.46
+
+acpmsRcPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C reactive power, in VAR."
+ ::= { acpmStatusEntry 47 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.47
+
+acpmsTAPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power, in VA."
+ ::= { acpmStatusEntry 48 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.48
+
+acpmsTAPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power minimum value since last reset, in VA."
+ ::= { acpmStatusEntry 49 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.49
+
+acpmsTAPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power maximum value since last reset, in VA."
+ ::= { acpmStatusEntry 50 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.50
+
+acpmsTAPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power average value since last reset, in VA."
+ ::= { acpmStatusEntry 51 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.51
+
+acpmsAPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A apparent power, in VA."
+ ::= { acpmStatusEntry 52 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.52
+
+acpmsAPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B apparent power, in VA."
+ ::= { acpmStatusEntry 53 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.53
+
+acpmsAPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C apparent power, in VA."
+ ::= { acpmStatusEntry 54 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.54
+
+acpmsTotalEnergyWh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total energy, in Wh."
+ ::= { acpmStatusEntry 55 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.55
+
+acpmsTotalEnergyVAR OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive energy, in VAR."
+ ::= { acpmStatusEntry 56 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.56
+
+acpmsTotalEnergyVA OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent energy, in VA."
+ ::= { acpmStatusEntry 57 }
+ --1.3.6.1.4.1.3052.12.1.8.1.1.57
+
+
+--***************************************************************************************
+--EventSensor Basics Section 2.1
+--***************************************************************************************
+
+esNumberEventSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of EventSensors recognized by the unit,
+ including the internal EventSensor.
+ Range: 1-17"
+ ::= { eventSensorBasics 1 }
+ --1.3.6.1.4.1.3052.12.2.1.1
+
+esTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESExist
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of what EventSensors are attached to the unit,
+ including the internal EventSensor"
+ ::= { eventSensorBasics 2 }
+ --1.3.6.1.4.1.3052.12.2.1.2
+
+esEntry OBJECT-TYPE
+ SYNTAX ESExist
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for EventSensor table"
+ INDEX { esIndex }
+ ::= { esTable 1 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1
+
+esIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This number refers to an EventSensor; it has the
+ same meaning as the esIndexES object (see above),
+ except that this object is used only within the
+ esTable branch.
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndex=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.1
+
+esName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the EventSensor"
+ ::= { esEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.2
+
+esID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The factory-assigned ID of the EventSensor"
+ ::= { esEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.3
+
+esNumberTempSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of temperature sensors on the EventSensor"
+ ::= { esEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.4
+
+esTempReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how temperature values should
+ be interpreted."
+ ::= { esEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.5
+
+esNumberCCs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of contact closures on the EventSensor."
+ ::= { esEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.6
+
+esCCReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how CC values should be interpreted."
+ ::= { esEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.7
+
+esNumberHumidSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of humidity sensors on the EventSensor."
+ ::= { esEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.8
+
+esHumidReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how humidity sensor values should be
+ interpreted."
+ ::= { esEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.9
+
+esNumberNoiseSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of noise sensors on the EventSensor."
+ ::= { esEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.10
+
+esNoiseReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how noise sensor values should be
+ interpreted."
+ ::= { esEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.11
+
+esNumberAirflowSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of airflow sensors on the EventSensor."
+ ::= { esEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.12
+
+esAirflowReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how airflow sensor values should be
+ interpreted."
+ ::= { esEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.13
+
+esNumberAnalog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of analog inputs on the EventSensor."
+ ::= { esEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.14
+
+esAnalogReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how analog input values should be
+ interpreted."
+ ::= { esEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.15
+
+esNumberOutputs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs (relay or power) on the EventSensor"
+ ::= { esEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.16
+
+esOutputReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how output values should be interpreted."
+ ::= { esEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.17
+
+esTempCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`value`scale`eventState`eventColorCode"
+ ::= { esEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.18
+
+esCCCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8"
+ ::= { esEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.19
+
+esCCCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16"
+ ::= { esEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.20
+
+esCCCombinedStatusBlock3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24"
+ ::= { esEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.21
+
+esCCCombinedStatusBlock4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32"
+ ::= { esEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.22
+
+esCCCombinedStatusBlock5 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40"
+ ::= { esEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.23
+
+esCCCombinedStatusBlock6 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48"
+ ::= { esEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.24
+
+esCCCombinedStatusBlock7 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56"
+ ::= { esEntry 25 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.25
+
+esCCCombinedStatusBlock8 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64"
+ ::= { esEntry 26 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.26
+
+esHumidCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`value`eventState`eventColorCode"
+ ::= { esEntry 27 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.27
+
+esAnalogCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~..."
+ ::= { esEntry 28 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.28
+
+esAnalogCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name9`value9`units9`eventState9`eventColorCode9~..."
+ ::= { esEntry 29 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.29
+
+esAnalogCombinedStatusBlock3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 30 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.31
+
+esAnalogCombinedStatusBlock4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 31 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.31
+
+esAnalogCombinedStatusBlock5 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 32 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.32
+
+esAnalogCombinedStatusBlock6 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 33 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.33
+
+esOutputCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 34 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.34
+
+esOutputCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz"
+ ::= { esEntry 35 }
+ --1.3.6.1.4.1.3052.12.2.1.2.1.35
+
+esNewSensors OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "String representing the number of new (attached but unconfigured) EventSensors"
+ ::= { eventSensorBasics 3 }
+ --1.3.6.1.4.1.3052.12.2.1.3
+
+
+--***************************************************************************************
+--EventSensor Point Config Section 2.2
+--***************************************************************************************
+
+
+
+esPointConfigTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigTemp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of temperature
+ sensor points. A point is a particular sensor on an
+ EventSensor. The 3 point attributes organizes in this table
+ are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number (always 1 for temp sensors)
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by periods.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ emperature point config table ; namely, which EventSensor,
+ and which sensor (a.k.a. point) (always 1 for temperature
+ sensors).
+ "
+ ::= { eventSensorPointConfig 1 }
+ --1.3.6.1.4.1.3052.12.2.2.1
+
+esPointConfigTempEntry OBJECT-TYPE
+ SYNTAX ESPointConfigTemp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config temperature table"
+ INDEX { espcTempIndexES, espcTempIndexPoint }
+ ::= { esPointConfigTempTable 1 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1
+
+espcTempIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config temperature table; namely, which EventSensor,
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndexES=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esPointConfigTempEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.1
+
+espcTempIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcTempIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of temperature point configuration."
+ ::= { esPointConfigTempEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.2
+
+espcTempEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this temperature sensor"
+ ::= { esPointConfigTempEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.3
+
+espcTempScale OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Scale (C/F) for this temperature sensor"
+ ::= { esPointConfigTempEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.4
+
+espcTempDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this temperature sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.5
+
+espcTempVHighTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.6
+
+espcTempVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event actions for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.7
+
+espcTempVHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event trap number for this
+ temperature sensor"
+ ::= { esPointConfigTempEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.8
+
+espcTempVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event class for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.9
+
+espcTempHighTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.10
+
+espcTempHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.11
+
+espcTempHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.12
+
+espcTempHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.13
+
+espcTempNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.14
+
+espcTempNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.15
+
+espcTempNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.16
+
+espcTempLowTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event threshold for this temperature sensor
+ (in floating-point format)"
+ ::= { esPointConfigTempEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.17
+
+espcTempLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.18
+
+espcTempLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.19
+
+espcTempLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.20
+
+espcTempVLowTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.21
+
+espcTempVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event actions for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.22
+
+espcTempVLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.23
+
+espcTempVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.2.1.1.24
+
+
+
+
+
+esPointConfigCCTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigCC
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of contact closure
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor within the context of this
+ contact closure point config table ; namely, which
+ EventSensor and which sensor.
+ "
+ ::= { eventSensorPointConfig 2 }
+ --1.3.6.1.4.1.3052.12.2.2.2
+
+esPointConfigCCEntry OBJECT-TYPE
+ SYNTAX ESPointConfigCC
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config contact closure table"
+ INDEX { espcCCIndexES, espcCCIndexPoint }
+ ::= { esPointConfigCCTable 1 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1
+
+espcCCIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigCCEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.1
+
+espcCCIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcCCIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigCCEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.2
+
+espcCCEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable for this contact closure"
+ ::= { esPointConfigCCEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.3
+
+espcCCName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this contact closure"
+ ::= { esPointConfigCCEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.4
+
+espcCCEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event state for this contact closure"
+ ::= { esPointConfigCCEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.5
+
+espcCCThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event threshold (seconds) for this contact closure"
+ ::= { esPointConfigCCEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.6
+
+espcCCEventActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event actions for this contact closure"
+ ::= { esPointConfigCCEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.7
+
+espcCCEventTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event trap number for this contact closure"
+ ::= { esPointConfigCCEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.8
+
+espcCCEventClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event class for this contact closure"
+ ::= { esPointConfigCCEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.9
+
+espcCCNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this contact closure"
+ ::= { esPointConfigCCEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.10
+
+espcCCNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this contact closure"
+ ::= { esPointConfigCCEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.11
+
+espcCCNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this contact closure"
+ ::= { esPointConfigCCEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.12
+
+espcCCAlarmAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event alias for this contact closure"
+ ::= { esPointConfigCCEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.13
+
+espcCCNormalAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal alias for this contact closure"
+ ::= { esPointConfigCCEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.14
+
+espcCCNormalThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event threshold (seconds) for this contact closure to return to normal"
+ ::= { esPointConfigCCEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.15
+
+espcCCOverrideGlobalReminder OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Override global reminder interval (evReminderInterval) for this CC."
+ ::= { esPointConfigCCEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.16
+
+espcCCReminderInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Individual reminder interval for this CC, applicable when the global
+ reminder is overriden."
+ ::= { esPointConfigCCEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.2.2.1.17
+
+
+
+esPointConfigHumidTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigHumid
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of humidity points.
+ A point is a particular sensor on an EventSensor. The 3
+ point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number (always 1 for humidity sensors)
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor within the context of this
+ humidity point config table ; namely, which EventSensor and
+ which sensor.
+ "
+ ::= { eventSensorPointConfig 3 }
+ --1.3.6.1.4.1.3052.12.2.2.3
+
+esPointConfigHumidEntry OBJECT-TYPE
+ SYNTAX ESPointConfigHumid
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config humidity table"
+ INDEX { espcHumidIndexES, espcHumidIndexPoint }
+ ::= { esPointConfigHumidTable 1 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1
+
+espcHumidIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigHumidEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.1
+
+espcHumidIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcHumidIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigHumidEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.2
+
+espcHumidEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable for this humidity sensor"
+ ::= { esPointConfigHumidEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.3
+
+espcHumidDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this humidity sensor"
+ ::= { esPointConfigHumidEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.4
+
+espcHumidVHighHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.5
+
+espcHumidVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.6
+
+espcHumidVHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.7
+
+espcHumidVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.8
+
+espcHumidHighHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.9
+
+espcHumidHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.10
+
+espcHumidHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.11
+
+espcHumidHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.12
+
+espcHumidNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.13
+
+espcHumidNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.14
+
+espcHumidNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.15
+
+espcHumidLowHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.16
+
+espcHumidLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.17
+
+espcHumidLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.18
+
+espcHumidLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.19
+
+espcHumidVLowHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.20
+
+espcHumidVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.21
+
+espcHumidVLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.22
+
+espcHumidVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.2.3.1.23
+
+
+esPointConfigAITable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigAnalogInput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of analog input
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ analog input point config table ; namely, which EventSensor
+ and which sensor.
+ "
+ ::= { eventSensorPointConfig 5 }
+ --1.3.6.1.4.1.3052.12.2.2.5
+
+esPointConfigAIEntry OBJECT-TYPE
+ SYNTAX ESPointConfigAnalogInput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config analog input table"
+ INDEX { espcHumidIndexES, espcHumidIndexPoint }
+ ::= { esPointConfigAITable 1 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1
+
+espcAIIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigAIEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.1
+
+espcAIIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcAIIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigAIEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.2
+
+espcAIEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for this analog input sensor"
+ ::= { esPointConfigAIEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.3
+
+espcAIDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this analog input sensor"
+ ::= { esPointConfigAIEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.5
+
+espcAIVhighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold (decivolts or tenths of
+ milliamps) for this analog input sensor"
+ ::= { esPointConfigAIEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.6
+
+espcAIVhighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.7
+
+espcAIVhighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.8
+
+espcAIVhighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.9
+
+espcAIHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold (decivolts or tenths of milliamps) for
+ this analog input sensor"
+ ::= { esPointConfigAIEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.10
+
+espcAIHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.11
+
+espcAIHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.12
+
+espcAIHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.13
+
+espcAINormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.14
+
+espcAINormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.15
+
+espcAINormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this analog input sensor"
+ ::= { esPointConfigAIEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.16
+
+espcAILowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold (decivolts or tenths of milliamps) for
+ this analog input sensor"
+ ::= { esPointConfigAIEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.17
+
+espcAILowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.18
+
+espcAILowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.19
+
+espcAILowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.20
+
+espcAIVlowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold (decivolts or tenths of milliamps)
+ for this analog input sensor"
+ ::= { esPointConfigAIEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.21
+
+espcAIVlowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.22
+
+espcAIVlowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.23
+
+espcAIVlowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.24
+
+espcAIConvUnitName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Converstion unit name for this analog input sensor"
+ ::= { esPointConfigAIEntry 25 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.25
+
+espcAIConvHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion high value for this analog input sensor"
+ ::= { esPointConfigAIEntry 26 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.26
+
+espcAIConvHighUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion high unit value for this analog input sensor"
+ ::= { esPointConfigAIEntry 27 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.27
+
+espcAIConvLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion low value for this analog input sensor"
+ ::= { esPointConfigAIEntry 29 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.29
+
+espcAIConvLowUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion unit low unit value for this analog input sensor"
+ ::= { esPointConfigAIEntry 30 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.30
+
+espcAIDisplayFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input display format"
+ ::= { esPointConfigAIEntry 32 }
+ --1.3.6.1.4.1.3052.12.2.2.5.1.32
+
+esPointConfigOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigOutput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes configuration items for output
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organized in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ output config table ; namely, which EventSensor
+ and which sensor.
+ "
+ ::= { eventSensorPointConfig 6 }
+ --1.3.6.1.4.1.3052.12.2.2.6
+
+esPointConfigOutputEntry OBJECT-TYPE
+ SYNTAX ESPointConfigOutput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config output table"
+ INDEX { espcOutputIndexES, espcOutputIndexPoint }
+ ::= { esPointConfigOutputTable 1 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1
+
+espcOutputIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigOutputEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.1
+
+espcOutputIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcOutputIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of output point configuration."
+ ::= { esPointConfigOutputEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.2
+
+espcOutputEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables the output event for this output. This has no effect
+ on whether the relay changes state, only on whether a state change
+ triggers an event."
+ ::= { esPointConfigOutputEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.3
+
+espcOutputActiveState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which state is considered the active state: energized/de-energized."
+ ::= { esPointConfigOutputEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.4
+
+espcOutputType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output type: RELAY, POWER, SSR, TTL."
+ ::= { esPointConfigOutputEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.5
+
+espcOutputAliasValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output alias corresponding to its event state."
+ ::= { esPointConfigOutputEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.6
+
+espcOutputAliasColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output color corresponding to its event state."
+ ::= { esPointConfigOutputEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.7
+
+espcOutputActiveAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alias for the output active state."
+ ::= { esPointConfigOutputEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.10
+
+espcOutputActiveColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output color (as rendered in the web UI, in RGB hex format) corresponding
+ to the output active state."
+ ::= { esPointConfigOutputEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.11
+
+espcOutputActiveActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output active event."
+ ::= { esPointConfigOutputEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.12
+
+espcOutputActiveTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (150..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output active event."
+ ::= { esPointConfigOutputEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.13
+
+espcOutputActiveClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the output active event."
+ ::= { esPointConfigOutputEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.14
+
+espcOutputInactiveAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alias for the output inactive state."
+ ::= { esPointConfigOutputEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.20
+
+espcOutputInactiveColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output color (as rendered in the web UI, in RGB hex format) corresponding
+ to the output inactive state."
+ ::= { esPointConfigOutputEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.21
+
+espcOutputInactiveActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output inactive event."
+ ::= { esPointConfigOutputEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.22
+
+espcOutputInactiveTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (150..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output inactive event."
+ ::= { esPointConfigOutputEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.23
+
+espcOutputInactiveClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the output inactive event."
+ ::= { esPointConfigOutputEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.2.6.1.24
+
+
+--***************************************************************************************
+--Serial Port Section 2.3
+--***************************************************************************************
+
+numberPorts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of RS-232 ports found.
+ Range: 2 or 4"
+ ::= { serialPorts 1 }
+ --1.3.6.1.4.1.3052.12.2.3.1
+
+portConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port config table"
+ ::= { serialPorts 2 }
+ --1.3.6.1.4.1.3052.12.2.3.2
+
+portConfigEntry OBJECT-TYPE
+ SYNTAX PortConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port config entry"
+ INDEX { portConfigIndex }
+ ::= { portConfigTable 1 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1
+
+portConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for ports"
+ ::= { portConfigEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.1
+
+portConfigBaud OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Baud rate, 19200, 9600, etc."
+ ::= { portConfigEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.2
+
+portConfigDataFormat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Value representing word length, parity, and
+ stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2"
+ ::= { portConfigEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.3
+
+portConfigStripPtOutputLfs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Strip passthrough LFs sent to device on this port:
+ 1=yes, 0=no."
+ ::= { portConfigEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.4
+
+portConfigStripPtInputLfs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Strip passthrough LFs received from device on this
+ port: 1=yes, 0=no."
+ ::= { portConfigEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.5
+
+portConfigMaskEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1=Use the character mask on this port. 0=Do
+ not use the mask. When the mask is enabled,
+ the following ASCII characters are ignored
+ on the port:
+ 0, 1, 4-9, 11, 12, 14-31, 128-255.
+ When the mask is disabled, all characters are
+ accepted on the port."
+ ::= { portConfigEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.7
+
+portConfigDAEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1=Enable the Data Alarm Evaluator for data
+ on this port. 0=Do not evaluate data on this
+ port."
+ ::= { portConfigEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.8
+
+portConfigStoreAlarmsDPT OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: store alarms received during passthrough"
+ ::= { portConfigEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.9
+
+portConfigRecordTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout after last unterminated data received upon
+ which data collected so far is stored as a record."
+ ::= { portConfigEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.10
+
+portConfigDataType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How the port interprets incoming data: ASCII/BINARY"
+ ::= { portConfigEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.11
+
+portConfigEtxToCRLF OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF whether the port translates incoming ETX to CRLF"
+ ::= { portConfigEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.12
+
+portConfigMLREnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Whether Multiline Records are collected on this port."
+ ::= { portConfigEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.13
+
+portConfigMLRStartField1Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR start field 1"
+ ::= { portConfigEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.14
+
+portConfigMLRStartField1Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR start field 1"
+ ::= { portConfigEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.15
+
+portConfigMLRStartField2Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR start field 2"
+ ::= { portConfigEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.16
+
+portConfigMLRStartField2Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR start field 2"
+ ::= { portConfigEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.17
+
+portConfigMLRNumLinesBefore OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of lines before the starting line which should
+ be included in the MLR"
+ ::= { portConfigEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.18
+
+portConfigMLREndDetection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How the MLR parser determines what ends an MLR: by FORMULA,
+ number of lines received so far (COUNT), or number of blank
+ lines received so far (BLANKS)"
+ ::= { portConfigEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.19
+
+portConfigMLRLineCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of lines in the MLR (used by the end detection mode)"
+ ::= { portConfigEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.20
+
+portConfigMLREndField1Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR end field 1"
+ ::= { portConfigEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.21
+
+portConfigMLREndField1Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR end field 1"
+ ::= { portConfigEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.22
+
+portConfigMLREndField2Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR end field 2"
+ ::= { portConfigEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.23
+
+portConfigMLREndField2Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR end field 2"
+ ::= { portConfigEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.24
+
+portConfigMLRUseComplexRules OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF MLR parser uses complex rules (field possitions/
+ formulas, etc.)"
+ ::= { portConfigEntry 25 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.25
+
+portConfigBufferPT OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF records received during passthrough mode are
+ buffered/stored in the database"
+ ::= { portConfigEntry 26 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.26
+
+portConfigId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The text identifer for the port"
+ ::= { portConfigEntry 27 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.27
+
+portConfigMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Mode of the serial port."
+ ::= { portConfigEntry 28 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.28
+
+portConfigHsk OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Handshaking mode of the serial port."
+ ::= { portConfigEntry 29 }
+ --1.3.6.1.4.1.3052.12.2.3.2.1.29
+
+
+--***************************************************************************************
+--Network Section 2.4
+--***************************************************************************************
+
+eth1Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of the Ethernet1 interface: STATIC,DHCP"
+ ::= { ethernet1 1 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.1.1
+
+eth1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 IP address"
+ ::= { ethernet1 2 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.1.2
+
+eth1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 subnet mask"
+ ::= { ethernet1 3 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.1.3
+
+eth1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 router"
+ ::= { ethernet1 4 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.1.4
+
+eth1MAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 MAC"
+ ::= { ethernet1 6 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.1.6
+
+
+eth2Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of the Ethernet2 interface: STATIC,DHCP"
+ ::= { ethernet2 1 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.2.1
+
+eth2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 IP address"
+ ::= { ethernet2 2 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.2.2
+
+eth2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 subnet mask"
+ ::= { ethernet2 3 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.2.3
+
+eth2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 router"
+ ::= { ethernet2 4 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.2.4
+
+eth2MAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 MAC"
+ ::= { ethernet2 6 }
+ --1.3.6.1.4.1.3052.12.2.4.1.1.2.6
+
+
+defaultRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default router/gateway"
+ ::= { network 2 }
+ --1.3.6.1.4.1.3052.12.2.4.2
+
+-- DNS
+
+dnsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DNSConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DNS server address table"
+ ::= { network 3 }
+ --1.3.6.1.4.1.3052.12.2.4.3
+
+dnsEntry OBJECT-TYPE
+ SYNTAX DNSConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DNS server address entry"
+ INDEX { dnsIndex }
+ ::= { dnsTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.3.1
+
+dnsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for DNS server address"
+ ::= { dnsEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.3.1.1
+
+dnsAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNS server address"
+ ::= { dnsEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.3.1.2
+
+hostname OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hostname of the unit"
+ ::= { network 4 }
+ --1.3.6.1.4.1.3052.12.2.4.4
+
+hostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Static host table"
+ ::= { network 5 }
+ --1.3.6.1.4.1.3052.12.2.4.5
+
+hostEntry OBJECT-TYPE
+ SYNTAX HostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Static host entry"
+ INDEX { hostIndex }
+ ::= { hostTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.5.1
+
+hostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for static host"
+ ::= { hostEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.5.1.1
+
+hostDeclaration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Static host declaration string (i.e. 'address hostname')"
+ ::= { hostEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.5.1.2
+
+-- Network Command Processor
+
+ncpDuplex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "For network command processor: 1=Input characters are echoed; 0=no echo."
+ ::= { network 6 }
+ --1.3.6.1.4.1.3052.12.2.4.6
+
+ncpTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Network command processor inactivity timeout"
+ ::= { network 7 }
+ --1.3.6.1.4.1.3052.12.2.4.7
+
+-- SNMP
+
+snmpAgentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for snmp agent"
+ ::= { snmp 1 }
+ --1.3.6.1.4.1.3052.12.2.4.8.1
+
+snmpNotificationCaptureEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit receives and stores SNMP traps/informs"
+ ::= { snmp 5 }
+ --1.3.6.1.4.1.3052.12.2.4.8.5
+
+snmpNotificationCaptureFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "File to which unit stores received SNMP traps/informs"
+ ::= { snmp 6 }
+ --1.3.6.1.4.1.3052.12.2.4.8.6
+
+snmpNtfnAttempts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum of times the unit attempts to send a notification
+ (trap/inform) in 1 cycle"
+ ::= { snmpNotificationTx 1 }
+ --1.3.6.1.4.1.3052.12.2.4.8.7.1
+
+snmpNtfnTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds between retries of sending a notification"
+ ::= { snmpNotificationTx 2 }
+ --1.3.6.1.4.1.3052.12.2.4.8.7.2
+
+snmpNtfnCycles OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of times the unit attempts a group of attempts to send
+ a notification (a cycle)"
+ ::= { snmpNotificationTx 3 }
+ --1.3.6.1.4.1.3052.12.2.4.8.7.3
+
+snmpNtfnSnooze OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes between cycles"
+ ::= { snmpNotificationTx 4 }
+ --1.3.6.1.4.1.3052.12.2.4.8.7.4
+
+
+-- FTP
+
+ftpPushEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable FTP push for REGULAR (protocol: FTP) or SECURE (protocol:
+ SFTP) operation, or disable it (OFF)"
+ ::= { ftpPush 1 }
+ --1.3.6.1.4.1.3052.12.2.4.9.1
+
+ftpPushServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP server to which data should be pushed"
+ ::= { ftpPush 2 }
+ --1.3.6.1.4.1.3052.12.2.4.9.2
+
+ftpPushAccount OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP push account"
+ ::= { ftpPush 5 }
+ --1.3.6.1.4.1.3052.12.2.4.9.5
+
+ftpPushDirectory OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP push directory"
+ ::= { ftpPush 6 }
+ --1.3.6.1.4.1.3052.12.2.4.9.6
+
+ftpPushperiod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes between pushes"
+ ::= { ftpPush 7 }
+ --1.3.6.1.4.1.3052.12.2.4.9.7
+
+ftpPushPushFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FTPPushPushFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of files to push"
+ ::= { ftpPush 8 }
+ --1.3.6.1.4.1.3052.12.2.4.9.8
+
+ftpPushPushFileEntry OBJECT-TYPE
+ SYNTAX FTPPushPushFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of files to push"
+ INDEX { ftpPushPushFileIndex }
+ ::= { ftpPushPushFileTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.9.8.1
+
+ftpPushPushFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of files to push"
+ ::= { ftpPushPushFileEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.9.8.1.1
+
+ftpPushPushFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push this local FILEx"
+ ::= { ftpPushPushFileEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.9.8.1.2
+
+ftpPushPushAudit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push the audit log"
+ ::= { ftpPush 9 }
+ --1.3.6.1.4.1.3052.12.2.4.9.9
+
+ftpPushPushAlarms OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push the alarms/events file"
+ ::= { ftpPush 10 }
+ --1.3.6.1.4.1.3052.12.2.4.9.10
+
+ftpPushRemoteFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FTPPushRemoteFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of remote names of files to push"
+ ::= { ftpPush 11 }
+ --1.3.6.1.4.1.3052.12.2.4.9.11
+
+ftpPushRemoteFileEntry OBJECT-TYPE
+ SYNTAX FTPPushRemoteFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of remote names of files to push"
+ INDEX { ftpPushRemoteFileIndex }
+ ::= { ftpPushRemoteFileTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.9.11.1
+
+ftpPushRemoteFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of remote names of files to push"
+ ::= { ftpPushRemoteFileEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.9.11.1
+
+ftpPushRemoteFileName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "remote name of pushed FILEx (name on server)"
+ ::= { ftpPushRemoteFileEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.9.11.2
+
+ftpPushRemoteAlarmName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filename on server for alarms"
+ ::= { ftpPush 12 }
+ --1.3.6.1.4.1.3052.12.2.4.9.12
+
+ftpPushPassive OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF use ftp passive mode"
+ ::= { ftpPush 13 }
+ --1.3.6.1.4.1.3052.12.2.4.9.13
+
+ftpPushIncludeDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include the date in the name of the pushed file"
+ ::= { ftpPush 14 }
+ --1.3.6.1.4.1.3052.12.2.4.9.14
+
+ftpPushIncludeTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include the time in the name of the pushed file"
+ ::= { ftpPush 15 }
+ --1.3.6.1.4.1.3052.12.2.4.9.15
+
+ftpPushIncludeSeq OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include a sequence number in the name of the pushed file"
+ ::= { ftpPush 16 }
+ --1.3.6.1.4.1.3052.12.2.4.9.16
+
+ftpPushPermissions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Unix permissions to apply to pushed files (octal notation)."
+ ::= { ftpPush 17 }
+ --1.3.6.1.4.1.3052.12.2.4.9.17
+
+
+pppDialEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF PPP dialout enabled"
+ ::= { pppDial 1 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.1
+
+pppDialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "phone number to dial"
+ ::= { pppDial 2 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.2
+
+pppDialIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds of inactivity after which the unit disconnects"
+ ::= { pppDial 5 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.5
+
+pppDialRetries OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of dialing retries for PPP"
+ ::= { pppDial 6 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.6
+
+pppDialCDTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds to wait after dialing for CD before
+ giving up"
+ ::= { pppDial 7 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.7
+
+pppDialLoginTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait to negotiate PPP after connecting"
+ ::= { pppDial 8 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.8
+
+pppDialMdmInit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem init string to use when dialing PPP"
+ ::= { pppDial 9 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.9
+
+pppDialSuggestIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address to suggest as the unit's end (local end) of the
+ PPP link"
+ ::= { pppDial 10 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.10
+
+pppDialPlainLogin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF look for login/password prompt before negotiating
+ PPP"
+ ::= { pppDial 11 }
+ --1.3.6.1.4.1.3052.12.2.4.10.1.11
+
+pppHostEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Unit accepts PPP negotiation"
+ ::= { pppHost 1 }
+ --1.3.6.1.4.1.3052.12.2.4.10.2.1
+
+pppHostIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds of inactivity after which PPP-hosted link will
+ terminate"
+ ::= { pppHost 2 }
+ --1.3.6.1.4.1.3052.12.2.4.10.2.2
+
+pppHostLocalIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Local IP address to negotiate"
+ ::= { pppHost 3 }
+ --1.3.6.1.4.1.3052.12.2.4.10.2.3
+
+pppHostRemoteIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote IP address to hand out to PPP peer"
+ ::= { pppHost 4 }
+ --1.3.6.1.4.1.3052.12.2.4.10.2.4
+
+-- Routing
+
+pppRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit routes IP traffic from PPP/Wireless to Ethernet"
+ ::= { routing 1 }
+ --1.3.6.1.4.1.3052.12.2.4.11.1
+
+routingInterface OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When pppRoutingEnable is enabled, this is the
+ Ethernet interface to which IP frames received on PPP are
+ routed"
+ ::= { routing 4 }
+ --1.3.6.1.4.1.3052.12.2.4.11.4
+
+-- IP Restrictions
+
+ipRestrictionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IPRestrictionConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of IP restrictions"
+ ::= { ipRestriction 1 }
+ --1.3.6.1.4.1.3052.12.2.4.12.1.1
+
+ipRestrictionEntry OBJECT-TYPE
+ SYNTAX IPRestrictionConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of IP restrictions"
+ INDEX { ipRestrictionIndex }
+ ::= { ipRestrictionTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.12.1.1
+
+ipRestrictionIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of IP restrictions"
+ ::= { ipRestrictionEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.12.1.1.1.1
+
+ipRestrictionEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this IP restriction"
+ ::= { ipRestrictionEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.12.1.1.1.2
+
+ipRestrictionMask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP restriction mask"
+ ::= { ipRestrictionEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.4.12.1.1.1.3
+
+
+-- RTS
+
+
+rtsFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RTSFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of RTS files"
+ ::= { rts 1 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1
+
+rtsFileEntry OBJECT-TYPE
+ SYNTAX RTSFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of RTS files"
+ INDEX { rtsFileIndex }
+ ::= { rtsFileTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1
+
+rtsFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of RTS files"
+ ::= { rtsFileEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.1
+
+rtsFileMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RTS mode (OFF,LISTEN,PUSH) for FILEx"
+ ::= { rtsFileEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.2
+
+rtsFileShowAnswer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Show answer string upon RTS connect for FILEx"
+ ::= { rtsFileEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.3
+
+rtsFileReqXON OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF require XON to start flow for FILEx"
+ ::= { rtsFileEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.4
+
+rtsFileTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Idle connection close timer (0 means no timeout) for FILEx"
+ ::= { rtsFileEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.5
+
+rtsFileEmptyClose OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF close the socket when FILEx is empty"
+ ::= { rtsFileEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.6
+
+rtsFilePushHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Host to which FILEx should be pushed via RTS"
+ ::= { rtsFileEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.7
+
+rtsFilePushPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port to which FILEx should be pushed via RTS"
+ ::= { rtsFileEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.8
+
+rtsFilePushRetryTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Retry timer (seconds) for retrying failed RTS push connect
+ attempts"
+ ::= { rtsFileEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.4.13.1.1.9
+
+-- RTS Alarms
+
+rtsAlarmsMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RTS mode (OFF,LISTEN,PUSH) for alarms file"
+ ::= { rtsAlarms 1 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2.1
+
+rtsAlarmsShowAnswer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Show answer string upon RTS connect for alarms file"
+ ::= { rtsAlarms 2 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2.2
+
+rtsAlarmsReqXON OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF require XON to start flow for alarms file"
+ ::= { rtsAlarms 3 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2.3
+
+rtsAlarmsTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Idle connection close timer (0 means no timeout) for alarms
+ file"
+ ::= { rtsAlarms 4 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2.4
+
+rtsAlarmsEmptyClose OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF close the socket when this file is empty for alarms
+ file"
+ ::= { rtsAlarms 5 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2.5
+
+rtsAlarmsPushHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Host to which alarms file should be pushed via RTS"
+ ::= { rtsAlarms 6 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2.6
+
+rtsAlarmsPushPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port to which alarms file should be pushed via RTS"
+ ::= { rtsAlarms 7 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2.7
+
+rtsAlarmsPushRetryTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Retry timer (seconds) for retrying failed RTS push connect
+ attempts"
+ ::= { rtsAlarms 8 }
+ --1.3.6.1.4.1.3052.12.2.4.13.2.8
+
+-- Traps
+
+trapIncludeDateTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include date and time in stock trap message"
+ ::= { trapInclude 1 }
+ --1.3.6.1.4.1.3052.12.2.4.14.1.1
+
+trapIncludeSiteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include site name in stock trap message"
+ ::= { trapInclude 2 }
+ --1.3.6.1.4.1.3052.12.2.4.14.1.2
+
+trapIncludeSensorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include sensor ID in stock trap message"
+ ::= { trapInclude 3 }
+ --1.3.6.1.4.1.3052.12.2.4.14.1.3
+
+trapIncludeUDName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include user defined name in stock trap message"
+ ::= { trapInclude 4 }
+ --1.3.6.1.4.1.3052.12.2.4.14.1.4
+
+trapIncludeUDState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include user defined state in stock trap message"
+ ::= { trapInclude 5 }
+ --1.3.6.1.4.1.3052.12.2.4.14.1.5
+
+trapIncludeSourceAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include source IP address in stock trap message"
+ ::= { trapInclude 6 }
+ --1.3.6.1.4.1.3052.12.2.4.14.1.6
+
+trapAuthFailEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable trap sent upon SNMP authentication failure"
+ ::= { trap 2 }
+ --1.3.6.1.4.1.3052.12.2.4.14.2
+
+-- Route testing
+
+routeTestEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable route testing"
+ ::= { routeTest 1 }
+ --1.3.6.1.4.1.3052.12.2.4.15.1
+
+
+routeTestPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The period which a route is considered valid"
+ ::= { routeTest 2 }
+ --1.3.6.1.4.1.3052.12.2.4.15.2
+
+routeTestAddressTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RouteTestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of route testing addresses"
+ ::= { routeTest 3 }
+ --1.3.6.1.4.1.3052.12.2.4.15.3
+
+routeTestAddressEntry OBJECT-TYPE
+ SYNTAX RouteTestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of RTS files"
+ INDEX { routeTestAddressIndex }
+ ::= { routeTestAddressTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.15.3.1
+
+routeTestAddressIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of RTS files"
+ ::= { routeTestAddressEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.15.3.1.1
+
+routeTestAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Address to ping to see if the route to it is valid"
+ ::= { routeTestAddressEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.15.3.1.2
+
+
+-- Wireless
+
+
+wirelessMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless mode (OFF,PERMANENT-EDGE)"
+ ::= { wireless 1 }
+ --1.3.6.1.4.1.3052.12.2.4.16.1
+
+wirelessAPN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless access point name"
+ ::= { wireless 2 }
+ --1.3.6.1.4.1.3052.12.2.4.16.2
+
+wirelessIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless idle timeout"
+ ::= { wireless 3 }
+ --1.3.6.1.4.1.3052.12.2.4.16.3
+
+wirelessDRE OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Default route enable for wireless network interface.
+ When this is ON, the wireless link, if up, becomes
+ the default route, overriding the default route setting
+ (defaultRouter object). When OFF, the default route
+ setting controls the default route and the wireless link
+ does not become the default route."
+ ::= { wireless 9 }
+ --1.3.6.1.4.1.3052.12.2.4.16.9
+
+wirelessPPPUsername OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Username for PPP-based wireless modem connections."
+ ::= { wireless 10 }
+ --1.3.6.1.4.1.3052.12.2.4.16.10
+
+wirelessFirewall OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem firewall."
+ ::= { wireless 11 }
+ --1.3.6.1.4.1.3052.12.2.4.16.11
+
+wirelessKeepaliveThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes of no RX activity before sending keep-alive."
+ ::= { wireless 12 }
+ --1.3.6.1.4.1.3052.12.2.4.16.12
+
+wirelessPPPDebug OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem PPP debug."
+ ::= { wireless 13 }
+ --1.3.6.1.4.1.3052.12.2.4.16.13
+
+wirelessConnEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem connectivity check."
+ ::= { wirelessConnectivity 1 }
+ --1.3.6.1.4.1.3052.12.2.4.16.20.1
+
+wirelessConnCheckInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check interval in minutes."
+ ::= { wirelessConnectivity 2 }
+ --1.3.6.1.4.1.3052.12.2.4.16.20.2
+
+wirelessConnFailThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity fail threshold."
+ ::= { wirelessConnectivity 3 }
+ --1.3.6.1.4.1.3052.12.2.4.16.20.3
+
+wirelessConnIP1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check IP address 1."
+ ::= { wirelessConnectivity 10 }
+ --1.3.6.1.4.1.3052.12.2.4.16.20.10
+
+wirelessConnIP2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check IP address 2."
+ ::= { wirelessConnectivity 11 }
+ --1.3.6.1.4.1.3052.12.2.4.16.20.11
+
+
+-- Email
+
+
+emailServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SMTP server to which the unit sends email"
+ ::= { email 1 }
+ --1.3.6.1.4.1.3052.12.2.4.17.1
+
+emailDomain OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Domain to use in recipient address"
+ ::= { email 2 }
+ --1.3.6.1.4.1.3052.12.2.4.17.2
+
+emailAuthEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable SMTP authentication"
+ ::= { email 3 }
+ --1.3.6.1.4.1.3052.12.2.4.17.3
+
+-- Advanced network config
+
+arpFilter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ARP filter code"
+ ::= { netAdvanced 1 }
+ --1.3.6.1.4.1.3052.12.2.4.18.1
+
+
+-- Web interface
+
+webEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for the web interface"
+ ::= { web 1 }
+ --1.3.6.1.4.1.3052.12.2.4.19.1
+
+webPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which web interface listens"
+ ::= { web 2 }
+ --1.3.6.1.4.1.3052.12.2.4.19.2
+
+webTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Web interface session timeout (seconds)"
+ ::= { web 3 }
+ --1.3.6.1.4.1.3052.12.2.4.19.3
+
+
+-- Ethernet Expansion
+
+ethExpanIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPv4 address of the unit reachable by nodes on the network interface
+ consisting of the Ethernet Expansion Card(s). If this is default
+ (0.0.0.0), then each card will still convey Ethernet traffic
+ (acting as Ethernet switch) among its nodes but those nodes will not
+ be able to communicate with the unit."
+ ::= { ethExpan 1 }
+ --1.3.6.1.4.1.3052.12.2.4.20.1
+
+ethExpanMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPv4 subnet mask for the Ethernet Expansion network interface."
+ ::= { ethExpan 2 }
+ --1.3.6.1.4.1.3052.12.2.4.20.2
+
+ethExpanCardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EthernetExpansionCardConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of Ethernet Expansion cards"
+ ::= { ethExpan 3 }
+ --1.3.6.1.4.1.3052.12.2.4.20.3
+
+ethExpanCardEntry OBJECT-TYPE
+ SYNTAX EthernetExpansionCardConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of Ethernet Expansion cards"
+ INDEX { ethExpanCardIndex }
+ ::= { ethExpanCardTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.20.3.1
+
+ethExpanCardIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of Ethernet Expansion cards"
+ ::= { ethExpanCardEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.20.3.1.1
+
+ethExpanCardMAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MAC address for each Ethernet Expansion Card that is bridged
+ together to form the Ethernet Expansion network interface."
+ ::= { ethExpanCardEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.20.3.1.2
+
+ethExpanDHCPStartIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Starting IP address for serving DHCP addresses on the Ethernet
+ Expansion network interface. If this is default (0.0.0.0) then
+ the unit will not run DHCP to serve addresses."
+ ::= { ethExpanDHCP 1 }
+ --1.3.6.1.4.1.3052.12.2.4.20.6.1
+
+ethExpanDHCPLeaseTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lease time for Ethernet Expansion DHCP clients in minutes."
+ ::= { ethExpanDHCP 2 }
+ --1.3.6.1.4.1.3052.12.2.4.20.6.2
+
+
+
+-- IPv6
+
+ipv6DefaultRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 default router in use."
+ ::= { ipv6 1 }
+ --1.3.6.1.4.1.3052.12.2.4.21.1
+
+
+
+-- CPE table
+
+cpeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CPEConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CPEs"
+ ::= { cpe 1 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1
+
+cpeEntry OBJECT-TYPE
+ SYNTAX CPEConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CPEs"
+ INDEX { cpeIndex }
+ ::= { cpeTable 1 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1
+
+cpeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CPEs"
+ ::= { cpeEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.1
+
+cpeHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE host (IP address or DNS name)"
+ ::= { cpeEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.2
+
+cpeName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE name, informational only"
+ ::= { cpeEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.3
+
+cpeDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE description, informational only"
+ ::= { cpeEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.4
+
+cpeKeepalive OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds between each successful ping request."
+ ::= { cpeEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.5
+
+cpeThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of unsuccessful pings that triggers the CPE event."
+ ::= { cpeEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.6
+
+cpeEventReminderInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE event reminder interval (minutes)."
+ ::= { cpeEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.7
+
+cpeKeepaliveTicks OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE ping period in 16ths of a second (nonzero overrides keepalive)."
+ ::= { cpeEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.20
+
+cpePingSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of bytes in CPE ping payload"
+ ::= { cpeEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.11
+
+cpeInfoReset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Set any number to reset CPE ping stats."
+ ::= { cpeEntry 30 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.30
+
+cpeInfoNumReq OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of requests transmitted."
+ ::= { cpeEntry 31 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.31
+
+cpeInfoNumGoodResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of non-corrupt responses."
+ ::= { cpeEntry 32 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.32
+
+cpeInfoNumBadResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of corrupt responses."
+ ::= { cpeEntry 33 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.33
+
+cpeInfoNumLostResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of requests with no response."
+ ::= { cpeEntry 34 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.34
+
+cpeInfoPercentLoss OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent loss (missing responses / total requests)."
+ ::= { cpeEntry 35 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.35
+
+cpeInfoPercentBad OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent corrupt (corrupt responses / total requests)."
+ ::= { cpeEntry 36 }
+ --1.3.6.1.4.1.3052.12.2.4.22.1.1.36
+
+--***************************************************************************************
+--Modem Section 2.5
+--***************************************************************************************
+
+
+
+
+
+modemFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem data format (8N1,7E1,7O1,7N1)"
+ ::= { modem 1 }
+ --1.3.6.1.4.1.3052.12.2.5.1
+
+modemInitString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Init string for modem"
+ ::= { modem 2 }
+ --1.3.6.1.4.1.3052.12.2.5.2
+
+
+modemCallAttempts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Max mumber of times the modem should try to call out until
+ successful connect"
+ ::= { modem 4 }
+ --1.3.6.1.4.1.3052.12.2.5.4
+
+modemCallDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum delay (seconds) between callouts"
+ ::= { modem 5 }
+ --1.3.6.1.4.1.3052.12.2.5.6
+
+
+modemCmdTimout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of minutes after which an idle command session via
+ modem is terminated"
+ ::= { modem 6 }
+ --1.3.6.1.4.1.3052.12.2.5.6
+
+modemGoto OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When a user connects, where that user is routed (command
+ session, passthrough to port 1, passthrough to port 2, etc.)"
+ ::= { modem 7 }
+ --1.3.6.1.4.1.3052.12.2.5.7
+
+
+modemCLIDEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Calling Line Identification security"
+ ::= { modemClid 1 }
+ --1.3.6.1.4.1.3052.12.2.5.8.1
+
+
+modemCLIDNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ModemCLIDNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of authorized callers identified by phone number"
+ ::= { modemClid 2 }
+ --1.3.6.1.4.1.3052.12.2.5.8.2
+
+modemCLIDNumberEntry OBJECT-TYPE
+ SYNTAX ModemCLIDNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CLID numbers"
+ INDEX { modemCLIDNumberIndex }
+ ::= { modemCLIDNumberTable 1 }
+ --1.3.6.1.4.1.3052.12.2.5.8.2.1
+
+modemCLIDNumberIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CLID numbers"
+ ::= { modemCLIDNumberEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.5.8.2.1.1
+
+modemCLIDNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "auhorized CLID number"
+ ::= { modemCLIDNumberEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.5.8.2.1.2
+
+modemTAPInitString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Init string to use for TAP (pager) connections"
+ ::= { modem 9 }
+ --1.3.6.1.4.1.3052.12.2.5.9
+
+modemTAP8N1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: use 8N1 data/parity/stop for TAP connections"
+ ::= { modem 10 }
+ --1.3.6.1.4.1.3052.12.2.5.10
+
+--***************************************************************************************
+--Time Section 2.8
+--***************************************************************************************
+
+clock OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text string for date and time;
+ e.g. 'SUN 01/02/98 12:34:27'. When setting
+ this object, only the date and time are
+ required; the unit will ignore a specified
+ day of week because it is calculated from
+ the date and time. When this object is included
+ in a notification as a varbind, it represents
+ the time that the triggering event occurred."
+ ::= { time 1 }
+ --1.3.6.1.4.1.3052.12.2.8.1
+
+--***************************************************************************************
+--Console Section 2.10
+--***************************************************************************************
+
+
+consoleDuplex OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF characters echoed on telnet command session"
+ ::= { console 1 }
+ --1.3.6.1.4.1.3052.12.2.10.1
+
+consoleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes of inactivity after which telnet command session is terminated"
+ ::= { console 2 }
+ --1.3.6.1.4.1.3052.12.2.10.2
+
+consoleConfirm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Prompt to confirm certain actions"
+ ::= { console 7 }
+ --1.3.6.1.4.1.3052.12.2.10.7
+
+--***************************************************************************************
+--Core Security Section 2.11.1
+--***************************************************************************************
+
+scShowPasswordPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF show password prompt upon login"
+ ::= { secCore 1 }
+ --1.3.6.1.4.1.3052.12.2.11.1.1
+
+scConsoleLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via console"
+ ::= { secCore 2 }
+ --1.3.6.1.4.1.3052.12.2.11.1.2
+
+scModemLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via modem"
+ ::= { secCore 3 }
+ --1.3.6.1.4.1.3052.12.2.11.1.3
+
+scTelnetLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via Telnet"
+ ::= { secCore 4 }
+ --1.3.6.1.4.1.3052.12.2.11.1.4
+
+scTelnetPTLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via Telnet to pass-
+ through ports (TCP ports 210x)"
+ ::= { secCore 5 }
+ --1.3.6.1.4.1.3052.12.2.11.1.5
+
+scRTSLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting to RTS (TCP ports 220x)"
+ ::= { secCore 6 }
+ --1.3.6.1.4.1.3052.12.2.11.1.6
+
+scAuthMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Authentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)"
+ ::= { secCore 7 }
+ --1.3.6.1.4.1.3052.12.2.11.1.7
+
+scRightsGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The set of aliases used for the 8 available rights levels"
+ ::= { secCore 8 }
+ --1.3.6.1.4.1.3052.12.2.11.1.8
+
+
+--***************************************************************************************
+--User Security Section 2.11.2
+--***************************************************************************************
+
+
+secUserTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SecUserConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of users"
+ ::= { unitSecurity 2 }
+ --1.3.6.1.4.1.3052.12.2.11.2
+
+secUserEntry OBJECT-TYPE
+ SYNTAX SecUserConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of users"
+ INDEX { secUserIndex }
+ ::= { secUserTable 1 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1
+
+secUserIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of users"
+ ::= { secUserEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.1
+
+secUserEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable user"
+ ::= { secUserEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.2
+
+secUserConnectVia OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Methods by which user is allowed to connect:
+ L=local (console)
+ T=Telnet
+ M=modem
+ F=FTP
+ R=RTS
+ S=SSH
+ "
+ ::= { secUserEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.5
+
+secUserLoginTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The function presented to the user upon login (COMMAND,
+ PASSTHROUGH,MENU)"
+ ::= { secUserEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.6
+
+secUserAccessFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default access file associated with the user"
+ ::= { secUserEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.7
+
+secUserPTEscapeTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The function presented to the user upon escaping pass-
+ through: currently only MENU"
+ ::= { secUserEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.9
+
+secUserPPPType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The kind of PPP access allowed to this user cannot connect
+ via PPP (NONE), can connect but only to the unit (LOCAL), or
+ can connect and route to Ethernet (ROUTING)"
+ ::= { secUserEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.10
+
+secUserRights OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The rights level granted to this user"
+ ::= { secUserEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.11
+
+secUserEventsReadAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to read the events/alarms file"
+ ::= { secUserEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.13
+
+secUserAuditReadAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to read the audit log"
+ ::= { secUserEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.14
+
+secUserEventsWriteAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to delete the events file"
+ ::= { secUserEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.16
+
+secUserAuditWriteAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to write to the audit log"
+ ::= { secUserEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.17
+
+secUserExpiration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Expiration date/time of this user"
+ ::= { secUserEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.18
+
+secUserCallbackNumber1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 1 the unit calls for dialback"
+ ::= { secUserEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.19
+
+secUserCallbackNumber2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 2 the unit calls for dialback"
+ ::= { secUserEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.20
+
+secUserCallbackNumber3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 3 the unit calls for dialback"
+ ::= { secUserEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.21
+
+secUserChallengeTelnetMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Telnet challenge mode: when user logs in via telnet, unit
+ allows access (OFF), presents a challenge (CHALLENGE), or
+ unit sends a one-time-password (SEND PASSWORD) to a
+ destination configured by secUserChallengeTelnetSendTo"
+ ::= { secUserEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.22
+
+secUserChallengeModemMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem challenge mode: when user logs in via modem, unit
+ allows access (OFF), presents a challenge (CHALLENGE), sends
+ a one-time-password (SEND PASSWORD) to a destination
+ configured by secUserChallengeTelnetSendTo, or dials a
+ number (CALLBACK) configured with secUserCallbackNumberx"
+ ::= { secUserEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.23
+
+secUserChallengeConsoleMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console challenge mode: when user logs in via console, unit
+ allows access (OFF), or presents a challenge (CHALLENGE)"
+ ::= { secUserEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.24
+
+secUserChallengeTelnetSendTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Email action used as the destination address for one-time-
+ password when a user logs in with a challenge mode of
+ SEND PASSWORD"
+ ::= { secUserEntry 25 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.25
+
+secUserChallengeModemSendTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem action used as the destination phone number for one-
+ time-password when a user logs in with a challenge mode of
+ SEND PASSWORD"
+ ::= { secUserEntry 26 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.26
+
+secUserChallengeExpiration OBJECT-TYPE
+ SYNTAX Integer32 (0..180)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time (in minutes) after which a one-time-password is sent
+ that it can be used to log in"
+ ::= { secUserEntry 27 }
+ --1.3.6.1.4.1.3052.12.2.11.2.1.27
+
+
+--***************************************************************************************
+--Factory Security Section 2.11.3
+--***************************************************************************************
+
+sfEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable factory access"
+ ::= { secFactory 1 }
+ --1.3.6.1.4.1.3052.12.2.11.3.1
+
+sfSecret OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Secret used for factory access"
+ ::= { secFactory 2 }
+ --1.3.6.1.4.1.3052.12.2.11.3.2
+
+
+
+--***************************************************************************************
+--Event Section 2.12
+--***************************************************************************************
+
+--***************************************************************************************
+--Event Core Section 2.12.1
+--***************************************************************************************
+
+
+evClassNameTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventClassConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of classes"
+ ::= { evCore 1 }
+ --1.3.6.1.4.1.3052.12.2.12.1.1
+
+evClassNameEntry OBJECT-TYPE
+ SYNTAX EventClassConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of classes"
+ INDEX { evClassNameIndex }
+ ::= { evClassNameTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.1.1.1
+
+evClassNameIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of classes"
+ ::= { evClassNameEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.1.1.1.1
+
+evClassName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class name for this slot"
+ ::= { evClassNameEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.1.1.1.2
+
+evReminderInterval OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval (minutes) between EventSensor reminder events"
+ ::= { evCore 2 }
+ --1.3.6.1.4.1.3052.12.2.12.1.2
+
+evLogEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable event log"
+ ::= { evLog 1 }
+ --1.3.6.1.4.1.3052.12.2.12.1.3.1
+
+evLogStoreAlarm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF store data alarms in event log"
+ ::= { evLog 2 }
+ --1.3.6.1.4.1.3052.12.2.12.1.3.2
+
+evLogMaxSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "max size (in KB) of event log"
+ ::= { evLog 3 }
+ --1.3.6.1.4.1.3052.12.2.12.1.3.3
+
+evLogStoreSensor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF store EventSensor events in event log"
+ ::= { evLog 4 }
+ --1.3.6.1.4.1.3052.12.2.12.1.3.4
+
+evLogTimeStampAlarms OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF put timestamps on event log entries"
+ ::= { evLog 5 }
+ --1.3.6.1.4.1.3052.12.2.12.1.3.5
+
+evLogPrependName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF prepend data event name to data alarm records in event
+ log"
+ ::= { evLog 6 }
+ --1.3.6.1.4.1.3052.12.2.12.1.3.6
+
+
+evMgmtReprocess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of sensors that have generated events since reset.
+ Write this to reprocess each sensor's last generated event
+ since reset. The value to write determines what kind of
+ events should be reprocessed:
+ 'all': all sensor events
+ 'cc': cc events
+ 'temperature': temperature events
+ 'humidity': humidity events
+ 'analog': analog input events"
+ ::= { evMgmt 3 }
+ --1.3.6.1.4.1.3052.12.2.12.1.4.3
+
+
+
+
+
+
+--***************************************************************************************
+--Data event section 2.12.2
+--***************************************************************************************
+
+evdExitOnTrue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: Data alarm evaluator stops checking record against
+ alarm equations when it finds an equation that matches"
+ ::= { evdCore 1 }
+ --1.3.6.1.4.1.3052.12.2.12.2.1.1.1
+
+evdFilterAction OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "What happens to a record that matches an equation:
+ REJECT/ACCEPT"
+ ::= { evdCore 2 }
+ --1.3.6.1.4.1.3052.12.2.12.2.1.1.2
+
+evdWildCardChar OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Character (in decimal ASCII code format) used to indicate
+ wildcards in data alarm equation"
+ ::= { evdCore 3 }
+ --1.3.6.1.4.1.3052.12.2.12.2.1.1.3
+
+
+evdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data events"
+ ::= { evData 2 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2
+
+evdEntry OBJECT-TYPE
+ SYNTAX DataEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data events"
+ INDEX { evdIndex }
+ ::= { evdTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1
+
+evdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data events"
+ ::= { evdEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.1
+
+evdEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this data event"
+ ::= { evdEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.2
+
+evdName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this data event"
+ ::= { evdEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.3
+
+evdEquation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Equation for this data event"
+ ::= { evdEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.4
+
+evdThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of equation matches that must happen to trigger this
+ data event"
+ ::= { evdEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.5
+
+evdAutoClear OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF this data alarm is automatically cleared (re-armed)
+ upon reaching the threshold number of matches"
+ ::= { evdEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.6
+
+evdClearInterval OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval at which this alarm is automatically cleared (no
+ bearing with evdAutoClear)"
+ ::= { evdEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.7
+
+evdClearTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tie of day (HH:MM) at which this data alarm is cleared (no
+ bearing with evdAutoClear)"
+ ::= { evdEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.8
+
+evdActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this data event"
+ ::= { evdEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.9
+
+evdClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this data event"
+ ::= { evdEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.10
+
+evdTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this event"
+ ::= { evdEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.11
+
+evdMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ALARM/FILTER: what is happens when this data event
+ triggers: either generate actions (mode=ALARM) )or
+ ACCEPT/REJECT (via evdFilterAction) the record
+ (mode=FILTER)"
+ ::= { evdEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.12.2.2.1.12
+
+evdFieldTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventFieldConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data event fields"
+ ::= { evData 3 }
+ --1.3.6.1.4.1.3052.12.2.12.2.3
+
+evdFieldEntry OBJECT-TYPE
+ SYNTAX DataEventFieldConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data event fields"
+ INDEX { evdFieldIndex }
+ ::= { evdFieldTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.2.3.1
+
+evdFieldIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data event fields"
+ ::= { evdFieldEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.2.3.1.1
+
+evdFieldStart OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start position (1-based) for this data event field"
+ ::= { evdFieldEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.2.3.1.2
+
+evdFieldLength OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of characters this data event field occupies"
+ ::= { evdFieldEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.2.3.1.3
+
+evdFieldName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start position (1-based) for this data event field"
+ ::= { evdFieldEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.2.3.1.4
+
+evdFieldLine OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Line number (1-based, for multiline records) for this data
+ event field"
+ ::= { evdFieldEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.2.3.1.5
+
+evdFieldType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alpha/Numeric type for this data event field"
+ ::= { evdFieldEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.2.3.1.6
+
+evdMacroTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventMacroConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data event macros"
+ ::= { evData 4 }
+ --1.3.6.1.4.1.3052.12.2.12.2.4
+
+evdMacroEntry OBJECT-TYPE
+ SYNTAX DataEventMacroConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data event macros"
+ INDEX { evdMacroIndex }
+ ::= { evdMacroTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.2.4.1
+
+evdMacroIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data event macros"
+ ::= { evdMacroEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.2.4.1.1
+
+evdMacroName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of this macro for use in data event equations"
+ ::= { evdMacroEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.2.4.1.2
+
+evdMacroEquation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Equation for this data event macro"
+ ::= { evdMacroEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.2.4.1.3
+
+--***************************************************************************************
+--No data event 1 Section 2.12.3
+--***************************************************************************************
+
+evNoData1Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this no data event"
+ ::= { evNoData1 1 }
+ --1.3.6.1.4.1.3052.12.2.12.3.1
+
+evNoData1Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this no data event"
+ ::= { evNoData1 2 }
+ --1.3.6.1.4.1.3052.12.2.12.3.2
+
+evNoData1Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this no data event"
+ ::= { evNoData1 3 }
+ --1.3.6.1.4.1.3052.12.2.12.3.3
+
+evNoData1TrapNum OBJECT-TYPE
+ SYNTAX Integer32 (505..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this no data event"
+ ::= { evNoData1 4 }
+ --1.3.6.1.4.1.3052.12.2.12.3.4
+
+evNoData1Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this no data event"
+ ::= { evNoData1 5 }
+ --1.3.6.1.4.1.3052.12.2.12.3.5
+
+evNoData1Sched1Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 begin time (HH:MM) for this no data event"
+ ::= { evNoData1 6 }
+ --1.3.6.1.4.1.3052.12.2.12.3.6
+
+evNoData1Sched1End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 end time (HH:MM) for this no data event"
+ ::= { evNoData1 7 }
+ --1.3.6.1.4.1.3052.12.2.12.3.7
+
+evNoData1Sched1Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 1 of this no data event"
+ ::= { evNoData1 8 }
+ --1.3.6.1.4.1.3052.12.2.12.3.8
+
+evNoData1Sched2Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 begin time (HH:MM) for this no data event"
+ ::= { evNoData1 9 }
+ --1.3.6.1.4.1.3052.12.2.12.3.9
+
+evNoData1Sched2End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 end time (HH:MM) for this no data event"
+ ::= { evNoData1 10 }
+ --1.3.6.1.4.1.3052.12.2.12.3.10
+
+evNoData1Sched2Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 2 of this no data event"
+ ::= { evNoData1 11 }
+ --1.3.6.1.4.1.3052.12.2.12.3.11
+
+evNoData1PortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NoDataEvent1PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of no data event 1 port enables"
+ ::= { evNoData1 12 }
+ --1.3.6.1.4.1.3052.12.2.12.3.12
+
+evNoData1PortEnableEntry OBJECT-TYPE
+ SYNTAX NoDataEvent1PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of no data event 1 port enables"
+ INDEX { evNoData1PortEnableIndex }
+ ::= { evNoData1PortEnableTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.3.12.1
+
+evNoData1PortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of no data event 1 port enables"
+ ::= { evNoData1PortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.3.12.1.1
+
+evNoData1PortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: no data event 1 observes this port"
+ ::= { evNoData1PortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.3.12.1.2
+
+evNoData1Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ no data event"
+ ::= { evNoData1 13 }
+ --1.3.6.1.4.1.3052.12.2.12.3.13
+
+evNoData1Days OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Days of the week on which this no event is active"
+ ::= { evNoData1 14 }
+ --1.3.6.1.4.1.3052.12.2.12.3.14
+
+--***************************************************************************************
+--No data event 2 Section 2.12.4
+--***************************************************************************************
+
+evNoData2Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this no data event"
+ ::= { evNoData2 1 }
+ --1.3.6.1.4.1.3052.12.2.12.4.1
+
+evNoData2Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this no data event"
+ ::= { evNoData2 2 }
+ --1.3.6.1.4.1.3052.12.2.12.4.2
+
+evNoData2Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this no data event"
+ ::= { evNoData2 3 }
+ --1.3.6.1.4.1.3052.12.2.12.4.3
+
+evNoData2TrapNum OBJECT-TYPE
+ SYNTAX Integer32 (505..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this no data event"
+ ::= { evNoData2 4 }
+ --1.3.6.1.4.1.3052.12.2.12.4.4
+
+evNoData2Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this no data event"
+ ::= { evNoData2 5 }
+ --1.3.6.1.4.1.3052.12.2.12.4.5
+
+evNoData2Sched1Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 begin time (HH:MM) for this no data event"
+ ::= { evNoData2 6 }
+ --1.3.6.1.4.1.3052.12.2.12.4.6
+
+evNoData2Sched1End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 end time (HH:MM) for this no data event"
+ ::= { evNoData2 7 }
+ --1.3.6.1.4.1.3052.12.2.12.4.7
+
+evNoData2Sched1Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 1 of this no data event"
+ ::= { evNoData2 8 }
+ --1.3.6.1.4.1.3052.12.2.12.4.8
+
+evNoData2Sched2Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 begin time (HH:MM) for this no data event"
+ ::= { evNoData2 9 }
+ --1.3.6.1.4.1.3052.12.2.12.4.9
+
+evNoData2Sched2End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 end time (HH:MM) for this no data event"
+ ::= { evNoData2 10 }
+ --1.3.6.1.4.1.3052.12.2.12.4.10
+
+evNoData2Sched2Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 2 of this no data event"
+ ::= { evNoData2 11 }
+ --1.3.6.1.4.1.3052.12.2.12.4.11
+
+evNoData2PortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NoDataEvent2PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of no data event 2 port enables"
+ ::= { evNoData2 12 }
+ --1.3.6.1.4.1.3052.12.2.12.4.12
+
+evNoData2PortEnableEntry OBJECT-TYPE
+ SYNTAX NoDataEvent2PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of no data event 2 port enables"
+ INDEX { evNoData2PortEnableIndex }
+ ::= { evNoData2PortEnableTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.4.12.1
+
+evNoData2PortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of no data event 2 port enables"
+ ::= { evNoData2PortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.4.12.1.1
+
+evNoData2PortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: no data event 2 observes this port"
+ ::= { evNoData2PortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.4.12.1.2
+
+evNoData2Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ no data event"
+ ::= { evNoData2 13 }
+ --1.3.6.1.4.1.3052.12.2.12.4.13
+
+evNoData2Days OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Days of the week on which this no event is active"
+ ::= { evNoData2 14 }
+ --1.3.6.1.4.1.3052.12.2.12.4.14
+
+--***************************************************************************************
+--Scheduled Event 1 Section 2.12.5
+--***************************************************************************************
+
+evSched1Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this scheduled event"
+ ::= { evSched1 1 }
+ --1.3.6.1.4.1.3052.12.2.12.5.1
+
+evSched1Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this scheduled event"
+ ::= { evSched1 2 }
+ --1.3.6.1.4.1.3052.12.2.12.5.2
+
+evSched1Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this scheduled event"
+ ::= { evSched1 3 }
+ --1.3.6.1.4.1.3052.12.2.12.5.3
+
+evSched1TrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this scheduled event"
+ ::= { evSched1 4 }
+ --1.3.6.1.4.1.3052.12.2.12.5.4
+
+evSched1Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this scheduled event"
+ ::= { evSched1 5 }
+ --1.3.6.1.4.1.3052.12.2.12.5.5
+
+evSched1Sunday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Sunday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 6 }
+ --1.3.6.1.4.1.3052.12.2.12.5.6
+
+evSched1Monday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Monday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 7 }
+ --1.3.6.1.4.1.3052.12.2.12.5.7
+
+evSched1Tuesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Tuesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 8 }
+ --1.3.6.1.4.1.3052.12.2.12.5.8
+
+evSched1Wednesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Wednesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 9 }
+ --1.3.6.1.4.1.3052.12.2.12.5.9
+
+evSched1Thursday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Thursday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 10 }
+ --1.3.6.1.4.1.3052.12.2.12.5.10
+
+evSched1Friday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Friday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 11 }
+ --1.3.6.1.4.1.3052.12.2.12.5.11
+
+evSched1Saturday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Saturday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 12 }
+ --1.3.6.1.4.1.3052.12.2.12.5.12
+
+evSched1Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ scheduled event"
+ ::= { evSched1 13 }
+ --1.3.6.1.4.1.3052.12.2.12.5.13
+
+
+--***************************************************************************************
+--Scheduled Event 2 Section 2.12.6
+--***************************************************************************************
+
+evSched2Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this scheduled event"
+ ::= { evSched2 1 }
+ --1.3.6.1.4.1.3052.12.2.12.6.1
+
+evSched2Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this scheduled event"
+ ::= { evSched2 2 }
+ --1.3.6.1.4.1.3052.12.2.12.6.2
+
+evSched2Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this scheduled event"
+ ::= { evSched2 3 }
+ --1.3.6.1.4.1.3052.12.2.12.6.3
+
+evSched2TrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this scheduled event"
+ ::= { evSched2 4 }
+ --1.3.6.1.4.1.3052.12.2.12.6.4
+
+evSched2Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this scheduled event"
+ ::= { evSched2 5 }
+ --1.3.6.1.4.1.3052.12.2.12.6.5
+
+evSched2Sunday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Sunday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 6 }
+ --1.3.6.1.4.1.3052.12.2.12.6.6
+
+evSched2Monday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Monday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 7 }
+ --1.3.6.1.4.1.3052.12.2.12.6.7
+
+evSched2Tuesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Tuesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 8 }
+ --1.3.6.1.4.1.3052.12.2.12.6.8
+
+evSched2Wednesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Wednesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 9 }
+ --1.3.6.1.4.1.3052.12.2.12.6.9
+
+evSched2Thursday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Thursday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 10 }
+ --1.3.6.1.4.1.3052.12.2.12.6.10
+
+evSched2Friday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Friday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 11 }
+ --1.3.6.1.4.1.3052.12.2.12.6.11
+
+evSched2Saturday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Saturday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 12 }
+ --1.3.6.1.4.1.3052.12.2.12.6.12
+
+evSched2Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ scheduled event"
+ ::= { evSched2 13 }
+ --1.3.6.1.4.1.3052.12.2.12.6.13
+
+--***************************************************************************************
+--Serial Handshaking Low Section 2.12.7
+--***************************************************************************************
+
+evShskLowTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SerialHandshakingLowEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of serial handshaking low events"
+ ::= { event 7 }
+ --1.3.6.1.4.1.3052.12.2.12.7
+
+evShskLowEntry OBJECT-TYPE
+ SYNTAX SerialHandshakingLowEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of serial handshaking low events"
+ INDEX { evShskLowIndex }
+ ::= { evShskLowTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.7.1
+
+evShskLowIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of serial handshaking low events"
+ ::= { evShskLowEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.7.1.1
+
+evShskLowEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enable the serial handshaking low event for this port"
+ ::= { evShskLowEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.7.1.2
+
+evShskLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.7.1.3
+
+evShskLowMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.7.1.4
+
+evShskLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.7.1.5
+
+evShskLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.7.1.6
+
+
+--***************************************************************************************
+--Serial Handshaking High Section 2.12.8
+--***************************************************************************************
+
+evShskHighTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SerialHandshakingHighEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of serial handshaking high events"
+ ::= { event 8 }
+ --1.3.6.1.4.1.3052.12.2.12.8
+
+evShskHighEntry OBJECT-TYPE
+ SYNTAX SerialHandshakingHighEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of serial handshaking high events"
+ INDEX { evShskHighIndex }
+ ::= { evShskHighTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.8.1
+
+evShskHighIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of serial handshaking high events"
+ ::= { evShskHighEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.8.1.1
+
+evShskHighEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enable the serial handshaking high event for this
+ port"
+ ::= { evShskHighEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.8.1.2
+
+evShskHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.8.1.3
+
+evShskHighMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.8.1.4
+
+evShskHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.8.1.5
+
+evShskHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the serial handshaking high event for this
+ port"
+ ::= { evShskHighEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.8.1.6
+
+
+
+--***************************************************************************************
+--No Sensor Event Section 2.12.9
+--***************************************************************************************
+
+evNoSensorTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout (seconds) after which an EventSensor becomes
+ unresponsive that this event is triggered"
+ ::= { evNoSensor 1 }
+ --1.3.6.1.4.1.3052.12.2.12.9.1
+
+evNoSensorActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for no sensor event"
+ ::= { evNoSensor 2 }
+ --1.3.6.1.4.1.3052.12.2.12.9.2
+
+evNoSensorTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for no sensor event"
+ ::= { evNoSensor 3 }
+ --1.3.6.1.4.1.3052.12.2.12.9.3
+
+evNoSensorClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for no sensor event"
+ ::= { evNoSensor 4 }
+ --1.3.6.1.4.1.3052.12.2.12.9.4
+
+
+
+--***************************************************************************************
+--Fuel Sensor Config Section 2.12.11
+--***************************************************************************************
+
+
+fuelSensorGeneralTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes general fuel sensor attributes."
+ ::= { fuelSensor 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1
+
+fsGenEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor general config table."
+ INDEX { fsGenIndex }
+ ::= { fuelSensorGeneralTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1
+
+fsGenIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor general config table."
+ ::= { fsGenEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.1
+
+fsGenName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor name."
+ ::= { fsGenEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.2
+
+fsGenSensorType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of fuel sensor in use; NONE disables the fuel sensor."
+ ::= { fsGenEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.3
+
+fsGenDistanceUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance units in use when setting and indicating tank dimensions."
+ ::= { fsGenEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.4
+
+fsGenRawValueTop OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input reading corresponding to the SENSOR FULL point."
+ ::= { fsGenEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.5
+
+fsGenTopOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance, in the specified distance unit, between the SENSOR FULL
+ point and the TANK FULL point. The value is positive if the
+ SENSOR FULL point is above the TANK FULL point, and negative if it is
+ below."
+ ::= { fsGenEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.6
+
+fsGenRawValueBottom OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input reading corresponding to the minimum fluid height
+ measurable by the fuel sensor."
+ ::= { fsGenEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.7
+
+fsGenBottomOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance, in the specified distance unit, between the SENSOR EMPTY
+ point and the TANK EMPTY point. The value is positive if the
+ SENSOR EMPTY point is above the TANK EMPTY point, and negative if it
+ is below."
+ ::= { fsGenEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.8
+
+fsGenInputES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which eventsensor contains the analog input associated with this fuel
+ sensor. Allowed values are 200 (for internal ES), or 1-16."
+ ::= { fsGenEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.9
+
+fsGenInputPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which analog input point, on the specified eventsensor, that is
+ associated with the fuel sensor."
+ ::= { fsGenEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.10
+
+fsGenFilterAveraging OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor filter averaging factor."
+ ::= { fsGenEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.11
+
+fsGenSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting enable."
+ ::= { fsGenEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.12
+
+fsGenSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting threshold (floating point value)."
+ ::= { fsGenEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.13
+
+fsGenSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting limit."
+ ::= { fsGenEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.14
+
+fsGenSysrepPackage OBJECT-TYPE
+ SYNTAX Integer32 (0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting package number."
+ ::= { fsGenEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.15
+
+fsGenSysrepType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor ASM profile type."
+ ::= { fsGenEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.16
+
+fsGenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor enable."
+ ::= { fsGenEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.17
+
+fsGenFuelType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of fuel being measured: DIESEL, PROPANE,
+ NATURAL GAS, HYDROGEN, GASOLINE, OTHER."
+ ::= { fsGenEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.12.11.1.1.18
+
+fuelSensorTankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigTank
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes tank-specific fuel sensor attributes."
+ ::= { fuelSensor 2 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2
+
+fsTankEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigTank
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor tank config table."
+ INDEX { fsTankIndex }
+ ::= { fuelSensorTankTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2.1
+
+fsTankIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor tank config table."
+ ::= { fsTankEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2.1.1
+
+fsTankHeight OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Height of the tank, from the TANK EMPTY point to the TANK FULL point,
+ in the specified distance unit (i.e. TANK HEIGHT). This is a
+ floating point value."
+ ::= { fsTankEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2.1.2
+
+fsTankDimA OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tank dimension measurement A for certain tank profiles. For
+ HORIZ OVAL, this is the length of the straight section. This is a
+ floating point value."
+ ::= { fsTankEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2.1.3
+
+fsTankDimB OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tank dimension measurement B for certain tank profiles. For
+ HORIZ OVAL, this is the radius of the curved section. This is a
+ floating point value."
+ ::= { fsTankEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2.1.4
+
+fsTankVolume OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How many volume units the tank contains, when full. This is a
+ floating point value."
+ ::= { fsTankEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2.1.5
+
+fsTankVolumeUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of the unit representing fluid volume in the tank. This is only
+ used for display purposes; it does not affect the volume calculation."
+ ::= { fsTankEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2.1.6
+
+fsTankShape OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The shape of the fuel tank. A value of LINEAR produces a fluid
+ volume reading that is directly proportional to fluid height. The
+ HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to
+ calculate the volume. The CUSTOM setting uses a strapping table that
+ must be configured as well (see fuelSensorCustomTankTable)."
+ ::= { fsTankEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.11.2.1.7
+
+
+fuelSensorCustomTankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigCustomTankStrapping
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes the custom tank strapping table. Each fuel
+ sensor has a table of height/volume pairs in service only when the tank
+ shape (fsTankShape) in CUSTOM. This allows the unit to calculate
+ volumes for nonstandard tank shapes, to the degree that accurate
+ height/volume measurements can be configured. This SNMP table has two
+ indexes: the first for which fuel sensor and the second for which
+ height/volume pair."
+ ::= { fuelSensor 3 }
+ --1.3.6.1.4.1.3052.12.2.12.11.3
+
+fsCustomTankEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigCustomTankStrapping
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor custom tank config table."
+ INDEX { fsCustomTankIndexFS, fsCustomTankIndexDatum }
+ ::= { fuelSensorCustomTankTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.3.1
+
+fsCustomTankIndexFS OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor tank config table. This is the
+ first of two indexes for this SNMP table."
+ ::= { fsCustomTankEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.3.1.1
+
+fsCustomTankIndexDatum OBJECT-TYPE
+ SYNTAX Integer32 (1..32)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which hight/volume pair: there are 32 pairs per fuel sensor. This is
+ the second of two indexes for this SNMP table."
+ ::= { fsCustomTankEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.11.3.1.2
+
+fsCustomTankHeight OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Height of custom tank height/volume pair. This is a floating point
+ value."
+ ::= { fsCustomTankEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.11.3.1.3
+
+fsCustomTankVolume OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volume of custom tank height/volume pair. This is a floating point
+ value."
+ ::= { fsCustomTankEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.11.3.1.4
+
+
+fuelSensorVolumeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigVolume
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes volume-event-specific fuel sensor attributes."
+ ::= { fuelSensor 4 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4
+
+fsVolumeEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigVolume
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor volume event config table."
+ INDEX { fsVolumeIndex }
+ ::= { fuelSensorVolumeTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1
+
+fsVolumeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor volume event config table."
+ ::= { fsVolumeEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.1
+
+fsVolumeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable fuel sensor volume events."
+ ::= { fsVolumeEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.2
+
+fsVolumeDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor deadband (hysteresis). This is a floating point value."
+ ::= { fsVolumeEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.3
+
+fsVolumeVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold value. This is a
+ floating point value."
+ ::= { fsVolumeEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.4
+
+fsVolumeVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold actions."
+ ::= { fsVolumeEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.5
+
+fsVolumeVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold trap number."
+ ::= { fsVolumeEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.6
+
+fsVolumeVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold class (severity)."
+ ::= { fsVolumeEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.7
+
+fsVolumeHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold value. This is a floating
+ point value."
+ ::= { fsVolumeEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.8
+
+fsVolumeHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold actions."
+ ::= { fsVolumeEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.9
+
+fsVolumeHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold trap number."
+ ::= { fsVolumeEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.10
+
+fsVolumeHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold class (severity)."
+ ::= { fsVolumeEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.11
+
+fsVolumeNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal actions."
+ ::= { fsVolumeEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.12
+
+fsVolumeNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal trap number."
+ ::= { fsVolumeEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.13
+
+fsVolumeNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal class (severity)."
+ ::= { fsVolumeEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.14
+
+fsVolumeLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold value. This is a floating
+ point value."
+ ::= { fsVolumeEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.15
+
+fsVolumeLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold actions."
+ ::= { fsVolumeEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.16
+
+fsVolumeLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold trap number."
+ ::= { fsVolumeEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.17
+
+fsVolumeLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold class (severity)."
+ ::= { fsVolumeEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.18
+
+fsVolumeVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold value. This is a
+ floating point value."
+ ::= { fsVolumeEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.19
+
+fsVolumeVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold actions."
+ ::= { fsVolumeEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.20
+
+fsVolumeVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold trap number."
+ ::= { fsVolumeEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.21
+
+fsVolumeVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold class (severity)."
+ ::= { fsVolumeEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.12.11.4.1.22
+
+
+
+fuelSensorDisconnectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes disconnect-event-specific fuel sensor attributes."
+ ::= { fuelSensor 5 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5
+
+fsDiscEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor disconnect event config table."
+ INDEX { fsDiscIndex }
+ ::= { fuelSensorDisconnectTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1
+
+fsDiscIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor disconnect event config table."
+ ::= { fsDiscEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.1
+
+fsDiscEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event enable."
+ ::= { fsDiscEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.2
+
+fsDiscHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High end of input value range when fuel sensor is disconnected. This
+ is in the units of the analog input value."
+ ::= { fsDiscEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.3
+
+fsDiscLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low end of input value range when fuel sensor is disconnected. This
+ is in the units of the analog input value."
+ ::= { fsDiscEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.4
+
+fsDiscActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event actions."
+ ::= { fsDiscEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.5
+
+fsDiscTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (515..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event trap number."
+ ::= { fsDiscEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.6
+
+fsDiscClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event class (severity)."
+ ::= { fsDiscEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.7
+
+fsDiscNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal actions."
+ ::= { fsDiscEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.8
+
+fsDiscNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (515..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal trap number."
+ ::= { fsDiscEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.9
+
+fsDiscNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal class (severity)."
+ ::= { fsDiscEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.11.5.1.10
+
+
+--***************************************************************************************
+--AC Power Monitor Config Section 2.12.12
+--***************************************************************************************
+
+acpmGeneralTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes general AC power monitor attributes."
+ ::= { acPowerMonitor 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1
+
+acpmGenEntry OBJECT-TYPE
+ SYNTAX ACPMConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor general config table."
+ INDEX { acpmGenIndex }
+ ::= { acpmGeneralTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1
+
+acpmGenIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor general config table."
+ ::= { acpmGenEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.1
+
+acpmGenDevice OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Model of the AC power monitor device. The unit needs this setting to
+ know which registers to poll for the various data items, among other
+ things."
+ ::= { acpmGenEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.2
+
+acpmGenName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for the AC power monitor device."
+ ::= { acpmGenEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.3
+
+acpmGenAddress OBJECT-TYPE
+ SYNTAX Integer32 (1..247)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modbus address of the AC power monitor device."
+ ::= { acpmGenEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.4
+
+acpmGenPtRatio OBJECT-TYPE
+ SYNTAX Integer32 (1..10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ratio of secondary turns to primary turns on potential transformers
+ (PT)."
+ ::= { acpmGenEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.5
+
+acpmGenCtRatio OBJECT-TYPE
+ SYNTAX Integer32 (1..10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ratio of secondary turns to primary turns on current transformers
+ (CT)."
+ ::= { acpmGenEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.6
+
+acpmGenPowerType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of power being monitored."
+ ::= { acpmGenEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.7
+
+acpmGenSysrepPackage OBJECT-TYPE
+ SYNTAX Integer32 (0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting package number."
+ ::= { acpmGenEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.8
+
+acpmGenSysrepType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ASM profile type."
+ ::= { acpmGenEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.9
+
+acpmGenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "AC power monitor enable."
+ ::= { acpmGenEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.12.1.1.10
+
+
+acpmAvgVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigAvgVoltage
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor average voltage attributes."
+ ::= { acPowerMonitor 2 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2
+
+acpmAvgVoltageEntry OBJECT-TYPE
+ SYNTAX ACPMConfigAvgVoltage
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor average voltage config table."
+ INDEX { acpmAvgVoltageIndex }
+ ::= { acpmAvgVoltageTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1
+
+acpmAvgVoltageIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor average voltage config
+ table."
+ ::= { acpmAvgVoltageEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.1
+
+acpmAvgVoltageEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor average voltage events."
+ ::= { acpmAvgVoltageEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.2
+
+acpmAvgVoltageDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for average voltage event. This is a floating
+ point value."
+ ::= { acpmAvgVoltageEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.3
+
+acpmAvgVoltageVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.4
+
+acpmAvgVoltageVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmAvgVoltageEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.5
+
+acpmAvgVoltageVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmAvgVoltageEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.6
+
+acpmAvgVoltageVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmAvgVoltageEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.7
+
+acpmAvgVoltageHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.8
+
+acpmAvgVoltageHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmAvgVoltageEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.9
+
+acpmAvgVoltageHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmAvgVoltageEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.10
+
+acpmAvgVoltageHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmAvgVoltageEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.11
+
+acpmAvgVoltageNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmAvgVoltageEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.12
+
+acpmAvgVoltageNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmAvgVoltageEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.13
+
+acpmAvgVoltageNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmAvgVoltageEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.14
+
+acpmAvgVoltageLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.15
+
+acpmAvgVoltageLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmAvgVoltageEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.16
+
+acpmAvgVoltageLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmAvgVoltageEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.17
+
+acpmAvgVoltageLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmAvgVoltageEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.18
+
+acpmAvgVoltageVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.19
+
+acpmAvgVoltageVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmAvgVoltageEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.20
+
+acpmAvgVoltageVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmAvgVoltageEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.21
+
+acpmAvgVoltageVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmAvgVoltageEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.22
+
+acpmAvgVoltageSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for average voltage telemetry."
+ ::= { acpmAvgVoltageEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.23
+
+acpmAvgVoltageSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for average voltage telemetry. This is a
+ floating point value."
+ ::= { acpmAvgVoltageEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.24
+
+acpmAvgVoltageSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for average voltage telemetry."
+ ::= { acpmAvgVoltageEntry 25 }
+ --1.3.6.1.4.1.3052.12.2.12.12.2.1.25
+
+
+acpmAvgCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigAvgCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor average current attributes."
+ ::= { acPowerMonitor 3 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3
+
+acpmAvgCurrentEntry OBJECT-TYPE
+ SYNTAX ACPMConfigAvgCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor average current config table."
+ INDEX { acpmAvgCurrentIndex }
+ ::= { acpmAvgCurrentTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1
+
+acpmAvgCurrentIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor average current config
+ table."
+ ::= { acpmAvgCurrentEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.1
+
+acpmAvgCurrentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor average current events."
+ ::= { acpmAvgCurrentEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.2
+
+acpmAvgCurrentDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for average current event. This is a floating
+ point value."
+ ::= { acpmAvgCurrentEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.3
+
+acpmAvgCurrentVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.4
+
+acpmAvgCurrentVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmAvgCurrentEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.5
+
+acpmAvgCurrentVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmAvgCurrentEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.6
+
+acpmAvgCurrentVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmAvgCurrentEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.7
+
+acpmAvgCurrentHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.8
+
+acpmAvgCurrentHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmAvgCurrentEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.9
+
+acpmAvgCurrentHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmAvgCurrentEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.10
+
+acpmAvgCurrentHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmAvgCurrentEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.11
+
+acpmAvgCurrentNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmAvgCurrentEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.12
+
+acpmAvgCurrentNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmAvgCurrentEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.13
+
+acpmAvgCurrentNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmAvgCurrentEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.14
+
+acpmAvgCurrentLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.15
+
+acpmAvgCurrentLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmAvgCurrentEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.16
+
+acpmAvgCurrentLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmAvgCurrentEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.17
+
+acpmAvgCurrentLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmAvgCurrentEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.18
+
+acpmAvgCurrentVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.19
+
+acpmAvgCurrentVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmAvgCurrentEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.20
+
+acpmAvgCurrentVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmAvgCurrentEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.21
+
+acpmAvgCurrentVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmAvgCurrentEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.22
+
+acpmAvgCurrentSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for average current telemetry."
+ ::= { acpmAvgCurrentEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.23
+
+acpmAvgCurrentSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for average current telemetry. This is
+ a floating point value."
+ ::= { acpmAvgCurrentEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.24
+
+acpmAvgCurrentSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for average current telemetry."
+ ::= { acpmAvgCurrentEntry 25 }
+ --1.3.6.1.4.1.3052.12.2.12.12.3.1.25
+
+
+acpmFreqTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigFreq
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor frequency attributes."
+ ::= { acPowerMonitor 4 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4
+
+acpmFreqEntry OBJECT-TYPE
+ SYNTAX ACPMConfigFreq
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor frequency config table."
+ INDEX { acpmFreqIndex }
+ ::= { acpmFreqTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1
+
+acpmFreqIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor frequency config table."
+ ::= { acpmFreqEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.1
+
+acpmFreqEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor frequency events."
+ ::= { acpmFreqEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.2
+
+acpmFreqDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for frequency event. This is a floating point
+ value."
+ ::= { acpmFreqEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.3
+
+acpmFreqVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.4
+
+acpmFreqVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmFreqEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.5
+
+acpmFreqVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmFreqEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.6
+
+acpmFreqVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmFreqEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.7
+
+acpmFreqHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.8
+
+acpmFreqHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmFreqEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.9
+
+acpmFreqHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmFreqEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.10
+
+acpmFreqHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmFreqEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.11
+
+acpmFreqNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmFreqEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.12
+
+acpmFreqNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmFreqEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.13
+
+acpmFreqNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmFreqEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.14
+
+acpmFreqLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.15
+
+acpmFreqLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmFreqEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.16
+
+acpmFreqLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmFreqEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.17
+
+acpmFreqLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmFreqEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.18
+
+acpmFreqVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.19
+
+acpmFreqVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmFreqEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.20
+
+acpmFreqVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmFreqEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.21
+
+acpmFreqVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmFreqEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.22
+
+acpmFreqSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for frequency telemetry."
+ ::= { acpmFreqEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.23
+
+acpmFreqSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for frequency telemetry. This is a
+ floating point value."
+ ::= { acpmFreqEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.24
+
+acpmFreqSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for frequency telemetry."
+ ::= { acpmFreqEntry 25 }
+ --1.3.6.1.4.1.3052.12.2.12.12.4.1.25
+
+
+acpmTotalRealPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigTRP
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor total real power attributes."
+ ::= { acPowerMonitor 5 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5
+
+acpmTRPEntry OBJECT-TYPE
+ SYNTAX ACPMConfigTRP
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor total real power config table."
+ INDEX { acpmTRPIndex }
+ ::= { acpmTotalRealPowerTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1
+
+acpmTRPIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor total real power
+ config table."
+ ::= { acpmTRPEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.1
+
+acpmTRPEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor total real power events."
+ ::= { acpmTRPEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.2
+
+acpmTRPDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for total real power event. This is a
+ floating point value."
+ ::= { acpmTRPEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.3
+
+acpmTRPVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.4
+
+acpmTRPVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmTRPEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.5
+
+acpmTRPVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmTRPEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.6
+
+acpmTRPVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmTRPEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.7
+
+acpmTRPHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.8
+
+acpmTRPHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmTRPEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.9
+
+acpmTRPHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmTRPEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.10
+
+acpmTRPHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmTRPEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.11
+
+acpmTRPNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmTRPEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.12
+
+acpmTRPNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmTRPEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.13
+
+acpmTRPNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmTRPEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.14
+
+acpmTRPLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.15
+
+acpmTRPLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmTRPEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.16
+
+acpmTRPLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmTRPEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.17
+
+acpmTRPLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmTRPEntry 18 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.18
+
+acpmTRPVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 19 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.19
+
+acpmTRPVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmTRPEntry 20 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.20
+
+acpmTRPVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmTRPEntry 21 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.21
+
+acpmTRPVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmTRPEntry 22 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.22
+
+acpmTRPSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for total real power telemetry."
+ ::= { acpmTRPEntry 23 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.23
+
+acpmTRPSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for total real power telemetry. This is a
+ floating point value."
+ ::= { acpmTRPEntry 24 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.24
+
+acpmTRPSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for total real power telemetry."
+ ::= { acpmTRPEntry 25 }
+ --1.3.6.1.4.1.3052.12.2.12.12.5.1.25
+
+
+acpmDisconnectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor device disconnect event
+ attributes."
+ ::= { acPowerMonitor 6 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6
+
+acpmDisconnectEntry OBJECT-TYPE
+ SYNTAX ACPMConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor device disconnect event config table."
+ INDEX { acpmDisconnectIndex }
+ ::= { acpmDisconnectTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1
+
+acpmDisconnectIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor device disconnect event
+ config table."
+ ::= { acpmDisconnectEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1.1
+
+acpmDisconnectEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor device disconnect event."
+ ::= { acpmDisconnectEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1.2
+
+acpmDisconnectActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for disconnect event."
+ ::= { acpmDisconnectEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1.3
+
+acpmDisconnectTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (524..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for disconnect event."
+ ::= { acpmDisconnectEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1.4
+
+acpmDisconnectClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for disconnect event."
+ ::= { acpmDisconnectEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1.5
+
+acpmDisconnectNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1.6
+
+acpmDisconnectNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (524..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1.7
+
+acpmDisconnectNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.12.6.1.8
+
+acpmTotalPowerFactorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigTotalPowerFactor
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor device total power factor
+ event attributes."
+ ::= { acPowerMonitor 7 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7
+
+acpmTPFEntry OBJECT-TYPE
+ SYNTAX ACPMConfigTotalPowerFactor
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor device total power factor event config
+ table."
+ INDEX { acpmTPFIndex }
+ ::= { acpmTotalPowerFactorTable 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1
+
+acpmTPFIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor device disconnect
+ event config table."
+ ::= { acpmTPFEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.1
+
+acpmTPFEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor device disconnect event."
+ ::= { acpmTPFEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.2
+
+acpmTPFDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis)."
+ ::= { acpmTPFEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.3
+
+acpmTPFNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal actions."
+ ::= { acpmTPFEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.4
+
+acpmTPFNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal trap number."
+ ::= { acpmTPFEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.5
+
+acpmTPFNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal class."
+ ::= { acpmTPFEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.6
+
+acpmTPFLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold."
+ ::= { acpmTPFEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.7
+
+acpmTPFLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low actions."
+ ::= { acpmTPFEntry 8 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.8
+
+acpmTPFLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low trap number."
+ ::= { acpmTPFEntry 9 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.9
+
+acpmTPFLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low class."
+ ::= { acpmTPFEntry 10 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.10
+
+acpmTPFVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low threshold."
+ ::= { acpmTPFEntry 11 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.11
+
+acpmTPFVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low actions."
+ ::= { acpmTPFEntry 12 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.12
+
+acpmTPFVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low trap number."
+ ::= { acpmTPFEntry 13 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.13
+
+acpmTPFVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low class."
+ ::= { acpmTPFEntry 14 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.14
+
+acpmTPFSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable."
+ ::= { acpmTPFEntry 15 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.15
+
+acpmTPFSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold."
+ ::= { acpmTPFEntry 16 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.16
+
+acpmTPFSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit."
+ ::= { acpmTPFEntry 17 }
+ --1.3.6.1.4.1.3052.12.2.12.12.7.1.17
+
+
+
+--***************************************************************************************
+--Reset Event Section 2.12.16
+--***************************************************************************************
+
+
+evResetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable reset event. This event is triggered when the unit
+ finishes booting."
+ ::= { evReset 1 }
+ --1.3.6.1.4.1.3052.12.2.12.16.1
+
+evResetDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..3600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds to wait after unit finishes booting before triggering
+ the reset event."
+ ::= { evReset 2 }
+ --1.3.6.1.4.1.3052.12.2.12.16.2
+
+evResetActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for reset event."
+ ::= { evReset 3 }
+ --1.3.6.1.4.1.3052.12.2.12.16.3
+
+evResetMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for reset event."
+ ::= { evReset 4 }
+ --1.3.6.1.4.1.3052.12.2.12.16.4
+
+evResetTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (543..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for reset event."
+ ::= { evReset 5 }
+ --1.3.6.1.4.1.3052.12.2.12.16.5
+
+evResetClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for reset event."
+ ::= { evReset 6 }
+ --1.3.6.1.4.1.3052.12.2.12.16.6
+
+
+--***************************************************************************************
+--Action Section 2.14
+--***************************************************************************************
+
+
+
+actionCallNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionCallNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of phone numbers to dial for modem actions"
+ ::= { action 1 }
+ --1.3.6.1.4.1.3052.12.2.14.1
+
+actionCallNumberEntry OBJECT-TYPE
+ SYNTAX ActionCallNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of phone numbers to dial for modem actions"
+ INDEX { actionCallNumberIndex }
+ ::= { actionCallNumberTable 1 }
+ --1.3.6.1.4.1.3052.12.2.14.1.1
+
+actionCallNumberIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of phone numbers to dial for modem actions"
+ ::= { actionCallNumberEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.14.1.1.1
+
+actionCallNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number to dial for this action slot"
+ ::= { actionCallNumberEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.14.1.1.2
+
+actionPagerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionPagerConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of pager configurations"
+ ::= { action 2 }
+ --1.3.6.1.4.1.3052.12.2.14.2
+
+actionPagerEntry OBJECT-TYPE
+ SYNTAX ActionPagerConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of pager configurations"
+ INDEX { actionPagerIndex }
+ ::= { actionPagerTable 1 }
+ --1.3.6.1.4.1.3052.12.2.14.2.1
+
+actionPagerIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "index for table of pager configurations"
+ ::= { actionPagerEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.14.2.1.1
+
+actionPagerType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "type of this pager configuration"
+ ::= { actionPagerEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.14.2.1.2
+
+actionPagerNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "phone number to dial for this pager configuration"
+ ::= { actionPagerEntry 3 }
+ --1.3.6.1.4.1.3052.12.2.14.2.1.3
+
+actionPagerID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID to use for this pager configuration"
+ ::= { actionPagerEntry 4 }
+ --1.3.6.1.4.1.3052.12.2.14.2.1.4
+
+actionPagerMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "message to use for this pager configuration"
+ ::= { actionPagerEntry 5 }
+ --1.3.6.1.4.1.3052.12.2.14.2.1.5
+
+actionPagerPostCalloutDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait after dialing before sending ID"
+ ::= { actionPagerEntry 6 }
+ --1.3.6.1.4.1.3052.12.2.14.2.1.6
+
+actionPagerPostIDDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait after sending ID to send message"
+ ::= { actionPagerEntry 7 }
+ --1.3.6.1.4.1.3052.12.2.14.2.1.7
+
+actionSchedEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable action schedule"
+ ::= { actionSched 1 }
+ --1.3.6.1.4.1.3052.12.2.14.3.1
+
+actionSchedBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "action schedule begin time (HH:MM)"
+ ::= { actionSched 2 }
+ --1.3.6.1.4.1.3052.12.2.14.3.2
+
+actionSchedEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "action schedule end time (HH:MM)"
+ ::= { actionSched 3 }
+ --1.3.6.1.4.1.3052.12.2.14.3.3
+
+actionSchedWeekdaysOnly OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF whether the action schedule applies to weekdays only
+ (ON) or all days (OFF)"
+ ::= { actionSched 4 }
+ --1.3.6.1.4.1.3052.12.2.14.3.4
+
+actionAsentriaRequireAck OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Asentria action requires an ack from the receiver"
+ ::= { actionAsentria 1 }
+ --1.3.6.1.4.1.3052.12.2.14.4.1
+
+actionAsentriaVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "version 1.0 or 1.1"
+ ::= { actionAsentria 2 }
+ --1.3.6.1.4.1.3052.12.2.14.4.2
+
+actionAsentriaTCPPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port used for TCP-based Asentria alarms"
+ ::= { actionAsentria 3 }
+ --1.3.6.1.4.1.3052.12.2.14.4.3
+
+actionHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of network hosts to use for network-based actions"
+ ::= { action 6 }
+ --1.3.6.1.4.1.3052.12.2.14.6
+
+actionHostEntry OBJECT-TYPE
+ SYNTAX ActionHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of network hosts to use for network-based
+ actions"
+ INDEX { actionHostIndex }
+ ::= { actionHostTable 1 }
+ --1.3.6.1.4.1.3052.12.2.14.6.1
+
+actionHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of network hosts to use for network-based
+ actions"
+ ::= { actionHostEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.14.6.1.1
+
+actionHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Hostname/IP address used as destination for network-based
+ action (e.g., trap)"
+ ::= { actionHostEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.14.6.1.2
+
+actionEmailTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionEmailConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of email addresses to use for email actions"
+ ::= { action 7 }
+ --1.3.6.1.4.1.3052.12.2.14.7
+
+actionEmailEntry OBJECT-TYPE
+ SYNTAX ActionEmailConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of email addresses to use for email actions"
+ INDEX { actionEmailIndex }
+ ::= { actionEmailTable 1 }
+ --1.3.6.1.4.1.3052.12.2.14.7.1
+
+actionEmailIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of email addresses to use for email actions"
+ ::= { actionEmailEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.14.7.1.1
+
+actionEmail OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "email address"
+ ::= { actionEmailEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.14.7.1.2
+
+actionParseError OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When a user attempts to configure an invalid action setting/
+ object, this object says why it was invalid."
+ ::= { action 8 }
+ --1.3.6.1.4.1.3052.12.2.14.8
+
+--***************************************************************************************
+--System Section 2.16
+--***************************************************************************************
+
+
+sysTimeAutoDST OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF automatically adjust for Daylight Savings Time"
+ ::= { sysTime 1 }
+ --1.3.6.1.4.1.3052.12.2.16.1.1
+
+sysTimeGMTOffset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Absolute value of offset (hours) from GMT of the timezone"
+ ::= { sysTime 2 }
+ --1.3.6.1.4.1.3052.12.2.16.1.2
+
+sysTimeGMTDirection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Direction (AHEAD/BEHIND) of timezone relative to GMT"
+ ::= { sysTime 3 }
+ --1.3.6.1.4.1.3052.12.2.16.1.3
+
+
+sysTimeNetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Network time mode"
+ ::= { sysTimeNet 1 }
+ --1.3.6.1.4.1.3052.12.2.16.1.4.1
+
+sysTimeNetHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NetworkTimeHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of hosts to use for network time services"
+ ::= { sysTimeNet 2 }
+ --1.3.6.1.4.1.3052.12.2.16.1.4.2
+
+sysTimeNetHostEntry OBJECT-TYPE
+ SYNTAX NetworkTimeHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of hosts to use for network time services"
+ INDEX { sysTimeNetHostIndex }
+ ::= { sysTimeNetHostTable 1 }
+ --1.3.6.1.4.1.3052.12.2.16.1.4.2.1
+
+sysTimeNetHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of hosts to use for network time services"
+ ::= { sysTimeNetHostEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.16.1.4.2.1.1
+
+sysTimeNetHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "host to use for network time services"
+ ::= { sysTimeNetHostEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.16.1.4.2.1.2
+
+sysPTTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout (minutes) of inactivity after which a pass-through
+ session is terminated (0 means it never terminates)"
+ ::= { sysPT 1 }
+ --1.3.6.1.4.1.3052.12.2.16.2.1
+
+sysPTEndPause OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "number of 16ths of a second between escape characters
+ received on pass-through origin IO handle that are reuired
+ for the escape characters to register as pass-through escape
+ characters in the pass-through escape sequence. Set to 0 to
+ make the escape character register as part of the pass-
+ through escape sequence without requiring a pause."
+ ::= { sysPT 2 }
+ --1.3.6.1.4.1.3052.12.2.16.2.2
+
+sysPTJoinable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable joinable pass-through sessions."
+ ::= { sysPT 3 }
+ --1.3.6.1.4.1.3052.12.2.16.2.3
+
+sysMTU OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum transfer unit for ethernet interfaces"
+ ::= { sys 3 }
+ --1.3.6.1.4.1.3052.12.2.16.3
+
+sysAnswerString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String displayed upon login"
+ ::= { sys 4 }
+ --1.3.6.1.4.1.3052.12.2.16.4
+
+sysEventFileID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID string for events file"
+ ::= { sys 6 }
+ --1.3.6.1.4.1.3052.12.2.16.6
+
+sysEscapeCharacter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Decimal ASCII code of the system escape character"
+ ::= { sys 7 }
+ --1.3.6.1.4.1.3052.12.2.16.7
+
+sysTimeStampTimeFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Format of time stamp: HH:MM,HH:MM:SS,BLANK"
+ ::= { sysTimeStamp 1 }
+ --1.3.6.1.4.1.3052.12.2.16.8.1
+
+sysTimeStampDateFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Format of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK"
+ ::= { sysTimeStamp 2 }
+ --1.3.6.1.4.1.3052.12.2.16.8.2
+
+sysTimeStampSpaceAfter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Inlude a space after timestamp"
+ ::= { sysTimeStamp 3 }
+ --1.3.6.1.4.1.3052.12.2.16.8.3
+
+sysLogMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Syslog mode: disabled, emit UDP (REMOTE), save in a
+ rotating file set (FILE), or emit on a listening socket
+ (SERVER)"
+ ::= { sysLog 1 }
+ --1.3.6.1.4.1.3052.12.2.16.9.1
+
+sysLoghost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Syslog host: destination machine when syslog mode is REMOTE"
+ ::= { sysLog 2 }
+ --1.3.6.1.4.1.3052.12.2.16.9.2
+
+sysLogFilter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String describing what functions place data in the syslog"
+ ::= { sysLog 3 }
+ --1.3.6.1.4.1.3052.12.2.16.9.3
+
+sysLogFileSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Size (in KB) of syslog files (when syslog mode is SERVER or
+ FILE)"
+ ::= { sysLog 4 }
+ --1.3.6.1.4.1.3052.12.2.16.9.4
+
+sysLogFileCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of files in syslog file set (when syslog mode is
+ SERVER or FILE)"
+ ::= { sysLog 5 }
+ --1.3.6.1.4.1.3052.12.2.16.9.5
+
+sysLogListenPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which the unit listens for a connection on
+ which syslog data is dumped (when syslog mode is SERVER)"
+ ::= { sysLog 6 }
+ --1.3.6.1.4.1.3052.12.2.16.9.6
+
+sysCRDBCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacity of Call Record Database (in KB)"
+ ::= { sysCRDB 1 }
+ --1.3.6.1.4.1.3052.12.2.16.10.1
+
+sysCRDBPercentFull OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of the CRDB used"
+ ::= { sysCRDB 2 }
+ --1.3.6.1.4.1.3052.12.2.16.10.2
+
+
+sysCRDBFileIDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CRDBFileIDConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CRDB file IDs"
+ ::= { sysCRDB 3 }
+ --1.3.6.1.4.1.3052.12.2.16.10.3
+
+sysCRDBFileIDEntry OBJECT-TYPE
+ SYNTAX CRDBFileIDConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CRDB file IDs"
+ INDEX { sysCRDBFileIDIndex }
+ ::= { sysCRDBFileIDTable 1 }
+ --1.3.6.1.4.1.3052.12.2.16.10.3.1
+
+sysCRDBFileIDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CRDB file IDs"
+ ::= { sysCRDBFileIDEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.16.10.3.1.1
+
+sysCRDBFileID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID of CRDB file for this port-associated file x"
+ ::= { sysCRDBFileIDEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.16.10.3.1.2
+
+sysCRDBFileEnforceMinTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CRDBFileEnforceMinConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CRDB file minimum size enforcement settings"
+ ::= { sysCRDB 4 }
+ --1.3.6.1.4.1.3052.12.2.16.10.4
+
+sysCRDBFileEnforceMinEntry OBJECT-TYPE
+ SYNTAX CRDBFileEnforceMinConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CRDB file minimum size enforcement
+ settings"
+ INDEX { sysCRDBFileEnforceMinIndex }
+ ::= { sysCRDBFileEnforceMinTable 1 }
+ --1.3.6.1.4.1.3052.12.2.16.10.4.1
+
+sysCRDBFileEnforceMinIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..24)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CRDB file minimum size enforcement
+ settings"
+ ::= { sysCRDBFileEnforceMinEntry 1 }
+ --1.3.6.1.4.1.3052.12.2.16.10.4.1.1
+
+sysCRDBFileEnforceMin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enforce minimum size for this CRDB file x"
+ ::= { sysCRDBFileEnforceMinEntry 2 }
+ --1.3.6.1.4.1.3052.12.2.16.10.4.1.2
+
+sysCharMask OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Character mask used for ignoring certain characters on
+ serial ports when assembling data records (when port mode is
+ ASCII)"
+ ::= { sys 11 }
+ --1.3.6.1.4.1.3052.12.2.16.11
+
+sysPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Prompt to use in a commnand session"
+ ::= { sys 12 }
+ --1.3.6.1.4.1.3052.12.2.16.12
+
+sysBootStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "String describing the boot status of the unit (Booted OK/
+ still booting"
+ ::= { sys 13 }
+ --1.3.6.1.4.1.3052.12.2.16.13
+
+sysLocLatitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Latitude portion of geographic coordinates as string"
+ ::= { sysLoc 1 }
+ --1.3.6.1.4.1.3052.12.2.16.14.1
+
+sysLocLongitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Longitude portion of geographic coordinates as string"
+ ::= { sysLoc 2 }
+ --1.3.6.1.4.1.3052.12.2.16.14.2
+
+sysLocXOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "X-offset portion of geographic coordinates as string"
+ ::= { sysLoc 3 }
+ --1.3.6.1.4.1.3052.12.2.16.14.3
+
+sysLocYOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Y offset portion of geographic coordinates as string"
+ ::= { sysLoc 4 }
+ --1.3.6.1.4.1.3052.12.2.16.14.4
+
+sysLocAngle OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Angle portion of geographic coordinates as string"
+ ::= { sysLoc 5 }
+ --1.3.6.1.4.1.3052.12.2.16.14.5
+
+sysLocAltitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Altitude as string"
+ ::= { sysLoc 6 }
+ --1.3.6.1.4.1.3052.12.2.16.14.6
+
+--***************************************************************************************
+--Sys Asset Managment 2.16.15
+--***************************************************************************************
+sysAMManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device manufacturer"
+ ::= { sysAssetMgmt 1 }
+ --1.3.6.1.4.1.3052.12.2.16.15.1
+
+sysAMProduct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device product description (i.e., model or model number)"
+ ::= { sysAssetMgmt 2 }
+ --1.3.6.1.4.1.3052.12.2.16.15.2
+
+sysAMSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manufacturer serial number for device"
+ ::= { sysAssetMgmt 3 }
+ --1.3.6.1.4.1.3052.12.2.16.15.3
+
+sysAMHardwareOptions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hardware options currently installed on device"
+ ::= { sysAssetMgmt 4 }
+ --1.3.6.1.4.1.3052.12.2.16.15.4
+
+sysAMSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently-running software version on device"
+ ::= { sysAssetMgmt 5 }
+ --1.3.6.1.4.1.3052.12.2.16.15.5
+
+sysAMSiteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Site Name of device (user definable, also known as the
+ siteName object under the productIds branch."
+ ::= { sysAssetMgmt 6 }
+ --1.3.6.1.4.1.3052.12.2.16.15.6
+
+--***************************************************************************************
+--Audit Log Section 2.17
+--***************************************************************************************
+
+auditLogEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable audit log"
+ ::= { auditLog 1 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStoreResets OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when the unit resets"
+ ::= { auditLog 2 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStoreCommands OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores commands entered in a command
+ session"
+ ::= { auditLog 3 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStoreOutputs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores output (relay output and power output)
+ activity"
+ ::= { auditLog 4 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStoreAlarmActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores action delivery activity"
+ ::= { auditLog 5 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStorePwdFailures OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when user was denied login"
+ ::= { auditLog 6 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStoreLogins OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when a user was allowed login"
+ ::= { auditLog 7 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStoreSHSK OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores serial handshaking status
+ (regardless of serial handshaking event)"
+ ::= { auditLog 8 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStorePassthrough OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores pass-through activity"
+ ::= { auditLog 9 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStoreInactivity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when sessions expire due to
+ inactivity"
+ ::= { auditLog 10 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogStorePolling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores CRDB polling activity"
+ ::= { auditLog 11 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+auditLogMaxSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum size (in KB) of audit log"
+ ::= { auditLog 12 }
+ --1.3.6.1.4.1.3052.12.2.17.1
+
+--***************************************************************************************
+--Product IDs Section 3
+--***************************************************************************************
+
+siteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Site Name string; Max 40 characters."
+ ::= { productIds 1 }
+ --1.3.6.1.4.1.3052.12.3.1
+
+thisProduct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is a factory configured string for the
+ product name."
+ ::= { productIds 2 }
+ --1.3.6.1.4.1.3052.12.3.2
+
+stockTrapString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The message defined for the event that triggers a trap."
+ ::= { productIds 3 }
+ --1.3.6.1.4.1.3052.12.3.3
+
+trapEventTypeNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the type of
+ event that happened. Definitions:
+ 4 Scheduled
+ 7 Serial Handshaking Low
+ 8 Serial Handshaking High
+ 10 Contact Closure Active
+ 11 Contact Closure Inactive
+ 12 Temperature High
+ 13 Temperature Very High
+ 14 Temperature Low
+ 15 Temperature Very Low
+ 16 Temperature Return to Normal
+ 17 Humidity High
+ 18 Humidity Very High
+ 19 Humidity Low
+ 20 Humidity Very Low
+ 21 Humidity Return to Normal
+ 26 Analog High
+ 27 Analog Very High
+ 28 Analog Low
+ 29 Analog Very Low
+ 30 Analog Normal
+ 40 EventSensor Unresponsive
+ 41 Custom
+ 42 CPE Down
+ 44 CPE Normal
+ 83 CPE Down Reminder
+ 100 Contact Closure Active Reminder
+ 101 Temperature High Reminder
+ 102 Temperature High Very Reminder
+ 103 Temperature Low Reminder
+ 104 Temperature Very Low Reminder
+ 105 Humidity High Reminder
+ 106 Humidity Very High Reminder
+ 107 Humidity Low Reminder
+ 108 Humidity Very Low Reminder
+ 109 Analog High Reminder
+ 110 Analog Very High Reminder
+ 111 Analog Low Reminder
+ 112 Analog Very Low Reminder
+ 130 Relay Output Active
+ 131 Relay Output Inactive
+ 132 Power Output On
+ 133 Power Output Off
+ 164 Reset
+ "
+ ::= { productIds 4 }
+ --1.3.6.1.4.1.3052.12.3.4
+
+trapEventTypeName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the string
+ corresponding to the event type."
+ ::= { productIds 5 }
+ --1.3.6.1.4.1.3052.12.3.5
+
+trapIncludedValue OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the generic
+ included value."
+ ::= { productIds 6 }
+ --1.3.6.1.4.1.3052.12.3.6
+
+trapIncludedString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the generic
+ included string."
+ ::= { productIds 7 }
+ --1.3.6.1.4.1.3052.12.3.7
+
+trapTypeString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The cause of the trap, added for DL880 compatibility."
+ ::= { productIds 8 }
+ --1.3.6.1.4.1.3052.12.3.8
+
+trapEventClassNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the configurable
+ class number associated with the triggering event."
+ ::= { productIds 9 }
+ --1.3.6.1.4.1.3052.12.3.9
+
+trapEventClassName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the configurable
+ class name associated with the class number."
+ ::= { productIds 10 }
+ --1.3.6.1.4.1.3052.12.3.10
+
+
+--***************************************************************************************
+--Product IDs Section 3
+--***************************************************************************************
+
+keyInterface OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object represents a setting key interface. When
+ setting this object, the value to set is the 'sk' command
+ you would enter on the command line (without the 'sk'). To
+ get the result of the operation, read this object after you
+ write it.
+
+ For example, to configure EventSensor 1 contact closure 34
+ event actions to be an SNMP InformRequest to host foo, set
+ this object to:
+ 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP
+ response is the result of the operation: if setting that key
+ to that value was a success then the SNMP response will be a
+ success and the response value will be what you had set. If
+ you subsequently read this object then you will see a
+ message 'OK: ...'.
+
+ If setting that key to that value failed then the SNMP
+ response will be a failure (a badValue response). If you
+ subsequently read this object then the value returned is the
+ reason that setting that key to that value failed.
+
+ For another example, to read user 3's pass-through access
+ for port 7, set this object to:
+ 'sec.user[3].port[7].ptaccess'. The SNMP response is the
+ result of the operation: if reading that key is a success
+ then the SNMP response will be a success and the response
+ value will be what you had SET (i.e., the opertion of
+ reading a key, which is just the key itself with no '='
+ operator, and this is not the key value you want to read).
+ If you subsequently read this object then the value
+ returned is the value of the key you want to read.
+
+ If reading that key failed (e.g., if the key is invalid)
+ then the SNMP response to your SNMP set operation (the
+ value you set being the invalid key to read) will be a
+ failure (a badValue response). If you subsequently read
+ this object then the value returned is the reason that
+ reading that key failed (i.e., 'invalid key')."
+ ::= { s530 4 }
+ --1.3.6.1.4.1.3052.12.4
+
+
+--***************************************************************************************
+--TABLE DEFINITIONS
+--***************************************************************************************
+
+ESPointConfigTemp ::=
+ SEQUENCE {
+ espcTempIndexES
+ Integer32,
+ espcTempIndexPoint
+ Integer32,
+ espcTempEnable
+ DisplayString,
+ espcTempScale
+ DisplayString,
+ espcTempDeadband
+ DisplayString,
+ espcTempVHighTemp
+ DisplayString,
+ espcTempVHighActions
+ DisplayString,
+ espcTempVHighTrapnum
+ Integer32,
+ espcTempVHighClass
+ DisplayString,
+ espcTempHighTemp
+ DisplayString,
+ espcTempHighActions
+ DisplayString,
+ espcTempHighTrapnum
+ Integer32,
+ espcTempHighClass
+ DisplayString,
+ espcTempNormalActions
+ DisplayString,
+ espcTempNormalTrapnum
+ Integer32,
+ espcTempNormalClass
+ DisplayString,
+ espcTempLowTemp
+ DisplayString,
+ espcTempLowActions
+ DisplayString,
+ espcTempLowTrapnum
+ Integer32,
+ espcTempLowClass
+ DisplayString,
+ espcTempVLowTemp
+ DisplayString,
+ espcTempVLowActions
+ DisplayString,
+ espcTempVLowTrapnum
+ Integer32,
+ espcTempVLowClass
+ DisplayString
+}
+
+
+ESPointConfigCC ::=
+ SEQUENCE {
+ espcCCIndexES
+ Integer32,
+ espcCCIndexPoint
+ Integer32,
+ espcCCEnable
+ DisplayString,
+ espcCCName
+ DisplayString,
+ espcCCEventState
+ DisplayString,
+ espcCCThreshold
+ Integer32,
+ espcCCEventActions
+ DisplayString,
+ espcCCEventTrapnum
+ Integer32,
+ espcCCEventClass
+ DisplayString,
+ espcCCNormalActions
+ DisplayString,
+ espcCCNormalTrapnum
+ Integer32,
+ espcCCNormalClass
+ DisplayString,
+ espcCCAlarmAlias
+ DisplayString,
+ espcCCNormalAlias
+ DisplayString,
+ espcCCNormalThreshold
+ Integer32,
+ espcCCOverrideGlobalReminder
+ DisplayString,
+ espcCCReminderInterval
+ Integer32
+}
+
+ESPointConfigHumid ::=
+ SEQUENCE {
+ espcHumidIndexES
+ Integer32,
+ espcHumidIndexPoint
+ Integer32,
+ espcHumidEnable
+ DisplayString,
+ espcHumidDeadband
+ Integer32,
+ espcHumidVHighHumid
+ Integer32,
+ espcHumidVHighActions
+ DisplayString,
+ espcHumidVHighTrapnum
+ Integer32,
+ espcHumidVHighClass
+ DisplayString,
+ espcHumidHighHumid
+ Integer32,
+ espcHumidHighActions
+ DisplayString,
+ espcHumidHighTrapnum
+ Integer32,
+ espcHumidHighClass
+ DisplayString,
+ espcHumidNormalActions
+ DisplayString,
+ espcHumidNormalTrapnum
+ Integer32,
+ espcHumidNormalClass
+ DisplayString,
+ espcHumidLowHumid
+ Integer32,
+ espcHumidLowActions
+ DisplayString,
+ espcHumidLowTrapnum
+ Integer32,
+ espcHumidLowClass
+ DisplayString,
+ espcHumidVLowHumid
+ Integer32,
+ espcHumidVLowActions
+ DisplayString,
+ espcHumidVLowTrapnum
+ Integer32,
+ espcHumidVLowClass
+ DisplayString
+}
+
+ESPointConfigAnalogInput ::=
+ SEQUENCE {
+ espcAIIndexES
+ Integer32,
+ espcAIIndexPoint
+ Integer32,
+ espcAIEnable
+ DisplayString,
+ espcAIDeadband
+ DisplayString,
+ espcAIVhighValue
+ DisplayString,
+ espcAIVhighActions
+ DisplayString,
+ espcAIVhighTrapnum
+ Integer32,
+ espcAIVhighClass
+ DisplayString,
+ espcAIHighValue
+ DisplayString,
+ espcAIHighActions
+ DisplayString,
+ espcAIHighTrapnum
+ Integer32,
+ espcAIHighClass
+ DisplayString,
+ espcAINormalActions
+ DisplayString,
+ espcAINormalTrapnum
+ Integer32,
+ espcAINormalClass
+ DisplayString,
+ espcAILowValue
+ DisplayString,
+ espcAILowActions
+ DisplayString,
+ espcAILowTrapnum
+ Integer32,
+ espcAILowClass
+ DisplayString,
+ espcAIVlowValue
+ DisplayString,
+ espcAIVlowActions
+ DisplayString,
+ espcAIVlowTrapnum
+ Integer32,
+ espcAIVlowClass
+ DisplayString,
+ espcAIConvUnitName
+ DisplayString,
+ espcAIConvHighValue
+ DisplayString,
+ espcAIConvHighUnit
+ DisplayString,
+ espcAIConvLowValue
+ DisplayString,
+ espcAIConvLowUnit
+ DisplayString,
+ espcAIDisplayFormat
+ DisplayString
+}
+
+
+ActionCallNumberConfig ::=
+ SEQUENCE {
+ actionCallNumberIndex
+ Integer32,
+ actionCallNumber
+ DisplayString
+
+}
+
+ActionPagerConfig ::=
+ SEQUENCE {
+ actionPagerIndex
+ Integer32,
+ actionPagerType
+ DisplayString,
+ actionPagerNumber
+ DisplayString,
+ actionPagerID
+ DisplayString,
+ actionPagerMessage
+ DisplayString,
+ actionPagerPostCalloutDelay
+ Integer32,
+ actionPagerPostIDDelay
+ Integer32
+}
+
+ESPointConfigOutput ::=
+ SEQUENCE {
+ espcOutputIndexES
+ Integer32,
+ espcOutputIndexPoint
+ Integer32,
+ espcOutputEnable
+ DisplayString,
+ espcOutputActiveState
+ DisplayString,
+ espcOutputType
+ DisplayString,
+ espcOutputAliasValue
+ DisplayString,
+ espcOutputAliasColor
+ DisplayString,
+ espcOutputActiveAlias
+ DisplayString,
+ espcOutputActiveColor
+ DisplayString,
+ espcOutputActiveActions
+ DisplayString,
+ espcOutputActiveTrapnum
+ Integer32,
+ espcOutputActiveClass
+ DisplayString,
+ espcOutputInactiveAlias
+ DisplayString,
+ espcOutputInactiveColor
+ DisplayString,
+ espcOutputInactiveActions
+ DisplayString,
+ espcOutputInactiveTrapnum
+ Integer32,
+ espcOutputInactiveClass
+ DisplayString
+}
+
+CPEConfig ::=
+ SEQUENCE {
+ cpeIndex
+ Integer32,
+ cpeHost
+ DisplayString,
+ cpeName
+ DisplayString,
+ cpeDescription
+ DisplayString,
+ cpeKeepalive
+ Integer32,
+ cpeThreshold
+ Integer32,
+ cpeEventReminderInterval
+ Integer32,
+ cpeKeepaliveTicks
+ Integer32,
+ cpePingSize
+ Integer32,
+ cpeInfoReset
+ Integer32,
+ cpeInfoNumReq
+ Integer32,
+ cpeInfoNumGoodResp
+ Integer32,
+ cpeInfoNumBadResp
+ Integer32,
+ cpeInfoNumLostResp
+ Integer32,
+ cpeInfoPercentLoss
+ DisplayString,
+ cpeInfoPercentBad
+ DisplayString
+}
+
+EventClassConfig ::=
+ SEQUENCE {
+ evClassNameIndex
+ Integer32,
+ evClassName
+ DisplayString
+}
+
+RTSFileConfig ::=
+ SEQUENCE {
+ rtsFileIndex
+ Integer32,
+ rtsFileMode
+ DisplayString,
+ rtsFileShowAnswer
+ DisplayString,
+ rtsFileReqXON
+ DisplayString,
+ rtsFileTimeout
+ Integer32,
+ rtsFileEmptyClose
+ DisplayString,
+ rtsFilePushHost
+ DisplayString,
+ rtsFilePushPort
+ Integer32,
+ rtsFilePushRetryTimer
+ Integer32
+}
+
+
+ModemCLIDLogConfig ::=
+ SEQUENCE {
+ modemCLIDLogIndex
+ Integer32,
+ modemCLIDLogNumber
+ DisplayString
+}
+
+CRDBFileEnforceMinConfig ::=
+ SEQUENCE {
+ sysCRDBFileEnforceMinIndex
+ Integer32,
+ sysCRDBFileEnforceMin
+ DisplayString
+}
+
+CRDBFileIDConfig ::=
+ SEQUENCE {
+ sysCRDBFileIDIndex
+ Integer32,
+ sysCRDBFileID
+ DisplayString
+}
+
+NetworkTimeHostConfig ::=
+ SEQUENCE {
+ sysTimeNetHostIndex
+ Integer32,
+ sysTimeNetHost
+ DisplayString
+}
+
+ActionHostConfig ::=
+ SEQUENCE {
+ actionHostIndex
+ Integer32,
+ actionHost
+ DisplayString
+}
+
+ActionEmailConfig ::=
+ SEQUENCE {
+ actionEmailIndex
+ Integer32,
+ actionEmail
+ DisplayString
+}
+
+FileEnforceMinimumConfig ::=
+ SEQUENCE {
+ sysCRDBFileEnforceMinIndex
+ Integer32,
+ sysCRDBFileEnforceMin
+ DisplayString
+}
+
+SerialHandshakingLowEventConfig ::=
+ SEQUENCE {
+ evShskLowIndex
+ Integer32,
+ evShskLowEnable
+ DisplayString,
+ evShskLowActions
+ DisplayString,
+ evShskLowMessage
+ DisplayString,
+ evShskLowClass
+ DisplayString,
+ evShskLowTrapNum
+ Integer32
+}
+
+SerialHandshakingHighEventConfig ::=
+ SEQUENCE {
+ evShskHighIndex
+ Integer32,
+ evShskHighEnable
+ DisplayString,
+ evShskHighActions
+ DisplayString,
+ evShskHighMessage
+ DisplayString,
+ evShskHighClass
+ DisplayString,
+ evShskHighTrapNum
+ Integer32
+}
+
+NoDataEvent1PortEnableConfig ::=
+ SEQUENCE {
+ evNoData1PortEnableIndex
+ Integer32,
+ evNoData1PortEnable
+ DisplayString
+}
+
+NoDataEvent2PortEnableConfig ::=
+ SEQUENCE {
+ evNoData2PortEnableIndex
+ Integer32,
+ evNoData2PortEnable
+ DisplayString
+}
+
+DataEventMacroConfig ::=
+ SEQUENCE {
+ evdMacroIndex
+ Integer32,
+ evdMacroName
+ DisplayString,
+ evdMacroEquation
+ DisplayString
+}
+
+DataEventFieldConfig ::=
+ SEQUENCE {
+ evdFieldIndex
+ Integer32,
+ evdFieldStart
+ Integer32,
+ evdFieldLength
+ Integer32,
+ evdFieldName
+ DisplayString,
+ evdFieldLine
+ Integer32,
+ evdFieldType
+ DisplayString
+}
+
+DataEventConfig ::=
+ SEQUENCE {
+ evdIndex
+ Integer32,
+ evdEnable
+ DisplayString,
+ evdName
+ DisplayString,
+ evdEquation
+ DisplayString,
+ evdThreshold
+ Integer32,
+ evdAutoClear
+ DisplayString,
+ evdClearInterval
+ DisplayString,
+ evdClearTime
+ DisplayString,
+ evdActions
+ DisplayString,
+ evdClass
+ DisplayString,
+ evdTrapNum
+ Integer32,
+ evdMode
+ DisplayString
+}
+
+SecUserConfig ::=
+ SEQUENCE {
+ secUserIndex
+ Integer32,
+ secUserEnable
+ DisplayString,
+ secUserConnectVia
+ DisplayString,
+ secUserLoginTo
+ DisplayString,
+ secUserAccessFile
+ DisplayString,
+ secUserPTEscapeTo
+ DisplayString,
+ secUserPPPType
+ DisplayString,
+ secUserRights
+ DisplayString,
+ secUserEventsReadAccess
+ DisplayString,
+ secUserAuditReadAccess
+ DisplayString,
+ secUserEventsWriteAccess
+ DisplayString,
+ secUserAuditWriteAccess
+ DisplayString,
+ secUserExpiration
+ DisplayString,
+ secUserCallbackNumber1
+ DisplayString,
+ secUserCallbackNumber2
+ DisplayString,
+ secUserCallbackNumber3
+ DisplayString,
+ secUserChallengeTelnetMode
+ DisplayString,
+ secUserChallengeModemMode
+ DisplayString,
+ secUserChallengeConsoleMode
+ DisplayString,
+ secUserChallengeTelnetSendTo
+ DisplayString,
+ secUserChallengeModemSendTo
+ DisplayString,
+ secUserChallengeExpiration
+ Integer32
+}
+
+
+
+
+ModemCLIDNumberConfig ::=
+ SEQUENCE {
+ modemCLIDNumberIndex
+ Integer32,
+ modemCLIDNumber
+ DisplayString
+}
+
+
+RouteTestConfig ::=
+ SEQUENCE {
+ routeTestAddressIndex
+ Integer32,
+ routeTestAddress
+ DisplayString
+}
+
+IPRestrictionConfig ::=
+ SEQUENCE {
+ ipRestrictionIndex
+ Integer32,
+ ipRestrictionEnable
+ DisplayString,
+ ipRestrictionMask
+ DisplayString
+}
+
+DNSConfig ::=
+ SEQUENCE {
+ dnsIndex
+ Integer32,
+ dnsAddress
+ IpAddress
+}
+
+HostConfig ::=
+ SEQUENCE {
+ hostIndex
+ Integer32,
+ hostDeclaration
+ DisplayString
+}
+
+FTPPushPushFileConfig ::=
+ SEQUENCE {
+ ftpPushPushFileIndex
+ Integer32,
+ ftpPushPushFile
+ DisplayString
+}
+
+FTPPushRemoteFileConfig ::=
+ SEQUENCE {
+ ftpPushRemoteFileIndex
+ Integer32,
+ ftpPushRemoteFileName
+ DisplayString
+}
+
+PortConfig ::=
+ SEQUENCE {
+ portConfigIndex
+ Integer32,
+ portConfigBaud
+ Integer32,
+ portConfigDataFormat
+ Integer32,
+ portConfigStripPtOutputLfs
+ Integer32,
+ portConfigStripPtInputLfs
+ Integer32,
+ portConfigMaskEnable
+ Integer32,
+ portConfigDAEnable
+ Integer32,
+ portConfigStoreAlarmsDPT
+ DisplayString,
+ portConfigRecordTimeout
+ Integer32,
+ portConfigDataType
+ DisplayString,
+ portConfigEtxToCRLF
+ DisplayString,
+ portConfigMLREnable
+ DisplayString,
+ portConfigMLRStartField1Pos
+ Integer32,
+ portConfigMLRStartField1Text
+ DisplayString,
+ portConfigMLRStartField2Pos
+ Integer32,
+ portConfigMLRStartField2Text
+ DisplayString,
+ portConfigMLRNumLinesBefore
+ Integer32,
+ portConfigMLREndDetection
+ DisplayString,
+ portConfigMLRLineCount
+ Integer32,
+ portConfigMLREndField1Pos
+ Integer32,
+ portConfigMLREndField1Text
+ DisplayString,
+ portConfigMLREndField2Pos
+ Integer32,
+ portConfigMLREndField2Text
+ DisplayString,
+ portConfigMLRUseComplexRules
+ DisplayString,
+ portConfigBufferPT
+ DisplayString,
+ portConfigId
+ DisplayString,
+ portConfigMode
+ DisplayString,
+ portConfigHsk
+ DisplayString
+
+}
+
+ESPoint ::=
+ SEQUENCE {
+ esIndexES
+ Integer32,
+ esIndexPC
+ Integer32,
+ esIndexPoint
+ Integer32,
+ esPointName
+ DisplayString,
+ esPointInEventState
+ Integer32,
+ esPointValueInt
+ Integer32,
+ esPointValueStr
+ DisplayString,
+ esPointTimeLastChange
+ DisplayString,
+ esPointTimetickLastChange
+ TimeTicks,
+ esPointAliasValueStr
+ DisplayString,
+ esPointClassValueStr
+ DisplayString
+}
+
+ESExist ::=
+ SEQUENCE {
+ esIndex
+ Integer32,
+ esName
+ DisplayString,
+ esID
+ DisplayString,
+ esNumberTempSensors
+ Integer32,
+ esTempReportingMode
+ DisplayString,
+ esNumberCCs
+ Integer32,
+ esCCReportingMode
+ DisplayString,
+ esNumberHumidSensors
+ Integer32,
+ esHumidReportingMode
+ DisplayString,
+ esNumberNoiseSensors
+ Integer32,
+ esNoiseReportingMode
+ DisplayString,
+ esNumberAirflowSensors
+ Integer32,
+ esAirflowReportingMode
+ DisplayString,
+ esNumberAnalog
+ Integer32,
+ esAnalogReportingMode
+ DisplayString,
+ esNumberOutputs
+ Integer32,
+ esOutputReportingMode
+ DisplayString,
+ esTempCombinedStatus
+ DisplayString,
+ esCCCombinedStatusBlock1
+ DisplayString,
+ esCCCombinedStatusBlock2
+ DisplayString,
+ esCCCombinedStatusBlock3
+ DisplayString,
+ esCCCombinedStatusBlock4
+ DisplayString,
+ esCCCombinedStatusBlock5
+ DisplayString,
+ esCCCombinedStatusBlock6
+ DisplayString,
+ esCCCombinedStatusBlock7
+ DisplayString,
+ esCCCombinedStatusBlock8
+ DisplayString,
+ esHumidCombinedStatus
+ DisplayString,
+ esAnalogCombinedStatusBlock1
+ DisplayString,
+ esAnalogCombinedStatusBlock2
+ DisplayString,
+ esAnalogCombinedStatusBlock3
+ DisplayString,
+ esAnalogCombinedStatusBlock4
+ DisplayString,
+ esAnalogCombinedStatusBlock5
+ DisplayString,
+ esAnalogCombinedStatusBlock6
+ DisplayString,
+ esOutputCombinedStatusBlock1
+ DisplayString,
+ esOutputCombinedStatusBlock2
+ DisplayString
+}
+
+DEStatus ::=
+ SEQUENCE {
+ deStatusIndex
+ Integer32,
+ deStatusName
+ DisplayString,
+ deStatusCounter
+ Integer32,
+ deStatusThreshold
+ Integer32
+}
+
+
+FSStatus ::=
+ SEQUENCE {
+ fsStatusIndex
+ Integer32,
+ fsStatusName
+ DisplayString,
+ fsStatusDeviceState
+ DisplayString,
+ fsStatusVolumeValueString
+ DisplayString,
+ fsStatusVolumePercentLevel
+ DisplayString,
+ fsStatusVolumeInEventState
+ DisplayString,
+ fsStatusCombined
+ DisplayString
+}
+
+ACPMStatus ::=
+ SEQUENCE {
+ acpmsIndex
+ Integer32,
+ acpmsName
+ DisplayString,
+ acpmsAvgVoltageValueStr
+ DisplayString,
+ acpmsAvgVoltageMinStr
+ DisplayString,
+ acpmsAvgVoltageMaxStr
+ DisplayString,
+ acpmsAvgVoltageAvgStr
+ DisplayString,
+ acpmsAvgVoltageInEventState
+ DisplayString,
+ acpmsVoltagePhaseAValueStr
+ DisplayString,
+ acpmsVoltagePhaseBValueStr
+ DisplayString,
+ acpmsVoltagePhaseCValueStr
+ DisplayString,
+ acpmsAvgCurrentValueStr
+ DisplayString,
+ acpmsAvgCurrentMinStr
+ DisplayString,
+ acpmsAvgCurrentMaxStr
+ DisplayString,
+ acpmsAvgCurrentAvgStr
+ DisplayString,
+ acpmsAvgCurrentInEventState
+ DisplayString,
+ acpmsCurrentPhaseAValueStr
+ DisplayString,
+ acpmsCurrentPhaseBValueStr
+ DisplayString,
+ acpmsCurrentPhaseCValueStr
+ DisplayString,
+ acpmsAvgFreqValueStr
+ DisplayString,
+ acpmsAvgFreqMinStr
+ DisplayString,
+ acpmsAvgFreqMaxStr
+ DisplayString,
+ acpmsAvgFreqAvgStr
+ DisplayString,
+ acpmsAvgFreqInEventState
+ DisplayString,
+ acpmsTRPValueStr
+ DisplayString,
+ acpmsTRPMinStr
+ DisplayString,
+ acpmsTRPMaxStr
+ DisplayString,
+ acpmsTRPAvgStr
+ DisplayString,
+ acpmsTRPInEventState
+ DisplayString,
+ acpmsRPPhaseAValueStr
+ DisplayString,
+ acpmsRPPhaseBValueStr
+ DisplayString,
+ acpmsRPPhaseCValueStr
+ DisplayString,
+ acpmsCombined
+ DisplayString,
+ acpmsTPFValueStr
+ DisplayString,
+ acpmsTPFMinStr
+ DisplayString,
+ acpmsTPFMaxStr
+ DisplayString,
+ acpmsTPFAvgStr
+ DisplayString,
+ acpmsTPFInEventState
+ DisplayString,
+ acpmsPFPhaseAValueStr
+ DisplayString,
+ acpmsPFPhaseBValueStr
+ DisplayString,
+ acpmsPFPhaseCValueStr
+ DisplayString,
+ acpmsTRcPValueStr
+ DisplayString,
+ acpmsTRcPMinStr
+ DisplayString,
+ acpmsTRcPMaxStr
+ DisplayString,
+ acpmsTRcPAvgStr
+ DisplayString,
+ acpmsRcPPhaseAValueStr
+ DisplayString,
+ acpmsRcPPhaseBValueStr
+ DisplayString,
+ acpmsRcPPhaseCValueStr
+ DisplayString,
+ acpmsTAPValueStr
+ DisplayString,
+ acpmsTAPMinStr
+ DisplayString,
+ acpmsTAPMaxStr
+ DisplayString,
+ acpmsTAPAvgStr
+ DisplayString,
+ acpmsAPPhaseAValueStr
+ DisplayString,
+ acpmsAPPhaseBValueStr
+ DisplayString,
+ acpmsAPPhaseCValueStr
+ DisplayString,
+ acpmsTotalEnergyWh
+ Integer32,
+ acpmsTotalEnergyVAR
+ Integer32,
+ acpmsTotalEnergyVA
+ Integer32
+}
+
+FuelSensorConfigGeneral ::=
+ SEQUENCE {
+ fsGenIndex
+ Integer32,
+ fsGenName
+ DisplayString,
+ fsGenSensorType
+ DisplayString,
+ fsGenDistanceUnit
+ DisplayString,
+ fsGenRawValueTop
+ DisplayString,
+ fsGenTopOffset
+ DisplayString,
+ fsGenRawValueBottom
+ DisplayString,
+ fsGenBottomOffset
+ DisplayString,
+ fsGenInputES
+ Integer32,
+ fsGenInputPoint
+ Integer32,
+ fsGenFilterAveraging
+ Integer32,
+ fsGenSysrepEnable
+ DisplayString,
+ fsGenSysrepThreshold
+ DisplayString,
+ fsGenSysrepLimit
+ Integer32,
+ fsGenSysrepPackage
+ Integer32,
+ fsGenSysrepType
+ DisplayString,
+ fsGenEnable
+ DisplayString,
+ fsGenFuelType
+ DisplayString
+}
+
+FuelSensorConfigTank ::=
+ SEQUENCE {
+ fsTankIndex
+ Integer32,
+ fsTankHeight
+ DisplayString,
+ fsTankDimA
+ DisplayString,
+ fsTankDimB
+ DisplayString,
+ fsTankVolume
+ DisplayString,
+ fsTankVolumeUnit
+ DisplayString,
+ fsTankShape
+ DisplayString
+}
+
+FuelSensorConfigCustomTankStrapping ::=
+ SEQUENCE {
+ fsCustomTankIndexFS
+ Integer32,
+ fsCustomTankIndexDatum
+ Integer32,
+ fsCustomTankHeight
+ DisplayString,
+ fsCustomTankVolume
+ DisplayString
+}
+
+FuelSensorConfigVolume ::=
+ SEQUENCE {
+ fsVolumeIndex
+ Integer32,
+ fsVolumeEnable
+ DisplayString,
+ fsVolumeDeadband
+ DisplayString,
+ fsVolumeVHighValue
+ DisplayString,
+ fsVolumeVHighActions
+ DisplayString,
+ fsVolumeVHighTrapNum
+ Integer32,
+ fsVolumeVHighClass
+ DisplayString,
+ fsVolumeHighValue
+ DisplayString,
+ fsVolumeHighActions
+ DisplayString,
+ fsVolumeHighTrapNum
+ Integer32,
+ fsVolumeHighClass
+ DisplayString,
+ fsVolumeNormalActions
+ DisplayString,
+ fsVolumeNormalTrapNum
+ Integer32,
+ fsVolumeNormalClass
+ DisplayString,
+ fsVolumeLowValue
+ DisplayString,
+ fsVolumeLowActions
+ DisplayString,
+ fsVolumeLowTrapNum
+ Integer32,
+ fsVolumeLowClass
+ DisplayString,
+ fsVolumeVLowValue
+ DisplayString,
+ fsVolumeVLowActions
+ DisplayString,
+ fsVolumeVLowTrapNum
+ Integer32,
+ fsVolumeVLowClass
+ DisplayString
+}
+
+FuelSensorConfigDisconnect ::=
+ SEQUENCE {
+ fsDiscIndex
+ Integer32,
+ fsDiscEnable
+ DisplayString,
+ fsDiscHighValue
+ DisplayString,
+ fsDiscLowValue
+ DisplayString,
+ fsDiscActions
+ DisplayString,
+ fsDiscTrapNum
+ Integer32,
+ fsDiscClass
+ DisplayString,
+ fsDiscNormalActions
+ DisplayString,
+ fsDiscNormalTrapNum
+ Integer32,
+ fsDiscNormalClass
+ DisplayString
+}
+
+ACPMConfigGeneral ::=
+ SEQUENCE {
+ acpmGenIndex
+ Integer32,
+ acpmGenDevice
+ DisplayString,
+ acpmGenName
+ DisplayString,
+ acpmGenAddress
+ Integer32,
+ acpmGenPtRatio
+ Integer32,
+ acpmGenCtRatio
+ Integer32,
+ acpmGenPowerType
+ DisplayString,
+ acpmGenSysrepPackage
+ Integer32,
+ acpmGenSysrepType
+ DisplayString,
+ acpmGenEnable
+ DisplayString
+}
+
+ACPMConfigAvgVoltage ::=
+ SEQUENCE {
+ acpmAvgVoltageIndex
+ Integer32,
+ acpmAvgVoltageEnable
+ DisplayString,
+ acpmAvgVoltageDeadband
+ DisplayString,
+ acpmAvgVoltageVHighValue
+ DisplayString,
+ acpmAvgVoltageVHighActions
+ DisplayString,
+ acpmAvgVoltageVHighTrapNum
+ Integer32,
+ acpmAvgVoltageVHighClass
+ DisplayString,
+ acpmAvgVoltageHighValue
+ DisplayString,
+ acpmAvgVoltageHighActions
+ DisplayString,
+ acpmAvgVoltageHighTrapNum
+ Integer32,
+ acpmAvgVoltageHighClass
+ DisplayString,
+ acpmAvgVoltageNormalActions
+ DisplayString,
+ acpmAvgVoltageNormalTrapNum
+ Integer32,
+ acpmAvgVoltageNormalClass
+ DisplayString,
+ acpmAvgVoltageLowValue
+ DisplayString,
+ acpmAvgVoltageLowActions
+ DisplayString,
+ acpmAvgVoltageLowTrapNum
+ Integer32,
+ acpmAvgVoltageLowClass
+ DisplayString,
+ acpmAvgVoltageVLowValue
+ DisplayString,
+ acpmAvgVoltageVLowActions
+ DisplayString,
+ acpmAvgVoltageVLowTrapNum
+ Integer32,
+ acpmAvgVoltageVLowClass
+ DisplayString,
+ acpmAvgVoltageSysrepEnable
+ DisplayString,
+ acpmAvgVoltageSysrepThreshold
+ DisplayString,
+ acpmAvgVoltageSysrepLimit
+ Integer32
+}
+
+ACPMConfigAvgCurrent ::=
+ SEQUENCE {
+ acpmAvgCurrentIndex
+ Integer32,
+ acpmAvgCurrentEnable
+ DisplayString,
+ acpmAvgCurrentDeadband
+ DisplayString,
+ acpmAvgCurrentVHighValue
+ DisplayString,
+ acpmAvgCurrentVHighActions
+ DisplayString,
+ acpmAvgCurrentVHighTrapNum
+ Integer32,
+ acpmAvgCurrentVHighClass
+ DisplayString,
+ acpmAvgCurrentHighValue
+ DisplayString,
+ acpmAvgCurrentHighActions
+ DisplayString,
+ acpmAvgCurrentHighTrapNum
+ Integer32,
+ acpmAvgCurrentHighClass
+ DisplayString,
+ acpmAvgCurrentNormalActions
+ DisplayString,
+ acpmAvgCurrentNormalTrapNum
+ Integer32,
+ acpmAvgCurrentNormalClass
+ DisplayString,
+ acpmAvgCurrentLowValue
+ DisplayString,
+ acpmAvgCurrentLowActions
+ DisplayString,
+ acpmAvgCurrentLowTrapNum
+ Integer32,
+ acpmAvgCurrentLowClass
+ DisplayString,
+ acpmAvgCurrentVLowValue
+ DisplayString,
+ acpmAvgCurrentVLowActions
+ DisplayString,
+ acpmAvgCurrentVLowTrapNum
+ Integer32,
+ acpmAvgCurrentVLowClass
+ DisplayString,
+ acpmAvgCurrentSysrepEnable
+ DisplayString,
+ acpmAvgCurrentSysrepThreshold
+ DisplayString,
+ acpmAvgCurrentSysrepLimit
+ Integer32
+}
+
+ACPMConfigFreq ::=
+ SEQUENCE {
+ acpmFreqIndex
+ Integer32,
+ acpmFreqEnable
+ DisplayString,
+ acpmFreqDeadband
+ DisplayString,
+ acpmFreqVHighValue
+ DisplayString,
+ acpmFreqVHighActions
+ DisplayString,
+ acpmFreqVHighTrapNum
+ Integer32,
+ acpmFreqVHighClass
+ DisplayString,
+ acpmFreqHighValue
+ DisplayString,
+ acpmFreqHighActions
+ DisplayString,
+ acpmFreqHighTrapNum
+ Integer32,
+ acpmFreqHighClass
+ DisplayString,
+ acpmFreqNormalActions
+ DisplayString,
+ acpmFreqNormalTrapNum
+ Integer32,
+ acpmFreqNormalClass
+ DisplayString,
+ acpmFreqLowValue
+ DisplayString,
+ acpmFreqLowActions
+ DisplayString,
+ acpmFreqLowTrapNum
+ Integer32,
+ acpmFreqLowClass
+ DisplayString,
+ acpmFreqVLowValue
+ DisplayString,
+ acpmFreqVLowActions
+ DisplayString,
+ acpmFreqVLowTrapNum
+ Integer32,
+ acpmFreqVLowClass
+ DisplayString,
+ acpmFreqSysrepEnable
+ DisplayString,
+ acpmFreqSysrepThreshold
+ DisplayString,
+ acpmFreqSysrepLimit
+ Integer32
+}
+
+ACPMConfigTRP ::=
+ SEQUENCE {
+ acpmTRPIndex
+ Integer32,
+ acpmTRPEnable
+ DisplayString,
+ acpmTRPDeadband
+ DisplayString,
+ acpmTRPVHighValue
+ DisplayString,
+ acpmTRPVHighActions
+ DisplayString,
+ acpmTRPVHighTrapNum
+ Integer32,
+ acpmTRPVHighClass
+ DisplayString,
+ acpmTRPHighValue
+ DisplayString,
+ acpmTRPHighActions
+ DisplayString,
+ acpmTRPHighTrapNum
+ Integer32,
+ acpmTRPHighClass
+ DisplayString,
+ acpmTRPNormalActions
+ DisplayString,
+ acpmTRPNormalTrapNum
+ Integer32,
+ acpmTRPNormalClass
+ DisplayString,
+ acpmTRPLowValue
+ DisplayString,
+ acpmTRPLowActions
+ DisplayString,
+ acpmTRPLowTrapNum
+ Integer32,
+ acpmTRPLowClass
+ DisplayString,
+ acpmTRPVLowValue
+ DisplayString,
+ acpmTRPVLowActions
+ DisplayString,
+ acpmTRPVLowTrapNum
+ Integer32,
+ acpmTRPVLowClass
+ DisplayString,
+ acpmTRPSysrepEnable
+ DisplayString,
+ acpmTRPSysrepThreshold
+ DisplayString,
+ acpmTRPSysrepLimit
+ Integer32
+}
+
+ACPMConfigDisconnect ::=
+ SEQUENCE {
+ acpmDisconnectIndex
+ Integer32,
+ acpmDisconnectEnable
+ DisplayString,
+ acpmDisconnectActions
+ DisplayString,
+ acpmDisconnectTrapNum
+ Integer32,
+ acpmDisconnectClass
+ DisplayString,
+ acpmDisconnectNormalActions
+ DisplayString,
+ acpmDisconnectNormalTrapNum
+ Integer32,
+ acpmDisconnectNormalClass
+ DisplayString
+}
+
+ACPMConfigTotalPowerFactor ::=
+ SEQUENCE {
+ acpmTPFIndex
+ Integer32,
+ acpmTPFEnable
+ DisplayString,
+ acpmTPFDeadband
+ DisplayString,
+ acpmTPFNormalActions
+ DisplayString,
+ acpmTPFNormalTrapNum
+ Integer32,
+ acpmTPFNormalClass
+ DisplayString,
+ acpmTPFLowValue
+ DisplayString,
+ acpmTPFLowActions
+ DisplayString,
+ acpmTPFLowTrapNum
+ Integer32,
+ acpmTPFLowClass
+ DisplayString,
+ acpmTPFVLowValue
+ DisplayString,
+ acpmTPFVLowActions
+ DisplayString,
+ acpmTPFVLowTrapNum
+ Integer32,
+ acpmTPFVLowClass
+ DisplayString,
+ acpmTPFSysrepEnable
+ DisplayString,
+ acpmTPFSysrepThreshold
+ DisplayString,
+ acpmTPFSysrepLimit
+ Integer32
+}
+
+EthernetExpansionCardConfig ::=
+ SEQUENCE {
+ ethExpanCardIndex
+ Integer32,
+ ethExpanCardMAC
+ DisplayString
+}
+
+--***************************************************************************************
+--TRAP DEFINITIONS
+--***************************************************************************************
+
+s530StockContactClosureTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock contact closure trap is issued when a contact closure
+ event happens."
+ ::= { s530 110 }
+
+s530StockTempTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock temperature trap is issued when a temperature event
+ happens."
+ ::= { s530 120 }
+
+s530StockHumidityTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock humidity trap is issued when a humidity event
+ happens."
+ ::= { s530 130 }
+
+s530StockAnalogTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when an analog sensor event
+ happens."
+ ::= { s530 140 }
+
+s530StockOutputTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock output trap is issued when an output event
+ happens. That is, depending on the configuration,
+ when an output changes state for any reason, this
+ trap will be sent."
+ ::= { s530 150 }
+
+s530StockPDCurrentTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ current event happens."
+ ::= { s530 180 }
+
+s530StockPDVoltageTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ voltage event happens."
+ ::= { s530 190 }
+
+s530StockPDFuseTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ fuse event happens."
+ ::= { s530 210 }
+
+s530StockDbasePfullTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock database percent full trap is issued
+ when the database size surpasses the threshold."
+ ::= { s530 501 }
+
+s530StockDataAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock data alarm trap is issued when a
+ data alarm happens."
+ ::= { s530 503 }
+
+s530StockNoDataAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock no-data alarm trap is issued when
+ the unit has received no data for a configured
+ interval within a configured schedule."
+ ::= { s530 505 }
+
+s530StockSchedTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock scheduled alarm trap is issued
+ when the current time reaches the scheduled
+ alarm time."
+ ::= { s530 506 }
+
+s530StockImmediateTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock immediate alarm trap is issued
+ when the user enters the DOTRAP command."
+ ::= { s530 507 }
+
+s530StockCTSTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock CTS trap is issued when an RS-232 CTS event
+ happens."
+ ::= { s530 510 }
+
+s530CPEDownTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock CPE Down trap is issued when a CPE Down event
+ happens."
+ ::= { s530 511 }
+
+s530FuelSensorDisconnectTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Disconnect trap is issued when a Fuel
+ Sensor Disconnect or Connect (Return to Normal) event happens."
+ ::= { s530 515 }
+
+s530FuelSensorVolumeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume trap is issued when a Fuel
+ Sensor Volume event happens"
+ ::= { s530 519 }
+
+s530ACPowerMonitorAvgVoltageTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor average voltage trap is issued when an
+ AC power monitor average voltage event happens."
+ ::= { s530 520 }
+
+s530ACPowerMonitorAvgCurrentTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor average current trap is issued when an
+ AC power monitor average current event happens."
+ ::= { s530 521 }
+
+s530ACPowerMonitorFrequencyTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor frequency trap is issued when an
+ AC power monitor frequency event happens."
+ ::= { s530 522 }
+
+s530ACPowerMonitorTRPTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor TRP (total real power) trap is issued
+ when an AC power monitor TRP event happens."
+ ::= { s530 523 }
+
+s530ACPowerMonitorDisconnectTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor disconnect trap is issued
+ when an AC power monitor disconnect event happens."
+ ::= { s530 524 }
+
+s530ACTotalPowerFactorTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor total power factor trap is issued
+ when an AC power monitor total power factor event happens."
+ ::= { s530 540 }
+
+s530ResetTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock reset trap is issued when a reset event happens."
+ ::= { s530 543 }
+
+s530UserTrap1000 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1000."
+ ::= { s530 1000 }
+
+s530UserTrap1001 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1001."
+ ::= { s530 1001 }
+
+s530UserTrap1002 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1002."
+ ::= { s530 1002 }
+
+s530UserTrap1003 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1003."
+ ::= { s530 1003 }
+
+s530UserTrap1004 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1004."
+ ::= { s530 1004 }
+
+s530UserTrap1005 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1005."
+ ::= { s530 1005 }
+
+s530UserTrap1006 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1006."
+ ::= { s530 1006 }
+
+s530UserTrap1007 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1007."
+ ::= { s530 1007 }
+
+s530UserTrap1008 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1008."
+ ::= { s530 1008 }
+
+s530UserTrap1009 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1009."
+ ::= { s530 1009 }
+
+s530UserTrap1010 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1010."
+ ::= { s530 1010 }
+
+s530UserTrap1011 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1011."
+ ::= { s530 1011 }
+
+s530UserTrap1012 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1012."
+ ::= { s530 1012 }
+
+s530UserTrap1013 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1013."
+ ::= { s530 1013 }
+
+s530UserTrap1014 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1014."
+ ::= { s530 1014 }
+
+s530UserTrap1015 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1015."
+ ::= { s530 1015 }
+
+s530UserTrap1016 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1016."
+ ::= { s530 1016 }
+
+s530UserTrap1017 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1017."
+ ::= { s530 1017 }
+
+s530UserTrap1018 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1018."
+ ::= { s530 1018 }
+
+s530UserTrap1019 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1019."
+ ::= { s530 1019 }
+
+s530UserTrap1020 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1020."
+ ::= { s530 1020 }
+
+s530UserTrap1021 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1021."
+ ::= { s530 1021 }
+
+s530UserTrap1022 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1022."
+ ::= { s530 1022 }
+
+s530UserTrap1023 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1023."
+ ::= { s530 1023 }
+
+s530UserTrap1024 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1024."
+ ::= { s530 1024 }
+
+s530UserTrap1025 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1025."
+ ::= { s530 1025 }
+
+s530UserTrap1026 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1026."
+ ::= { s530 1026 }
+
+s530UserTrap1027 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1027."
+ ::= { s530 1027 }
+
+s530UserTrap1028 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1028."
+ ::= { s530 1028 }
+
+s530UserTrap1029 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1029."
+ ::= { s530 1029 }
+
+s530UserTrap1030 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1030."
+ ::= { s530 1030 }
+
+s530UserTrap1031 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1031."
+ ::= { s530 1031 }
+
+s530UserTrap1032 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1032."
+ ::= { s530 1032 }
+
+s530UserTrap1033 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1033."
+ ::= { s530 1033 }
+
+s530UserTrap1034 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1034."
+ ::= { s530 1034 }
+
+s530UserTrap1035 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1035."
+ ::= { s530 1035 }
+
+s530UserTrap1036 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1036."
+ ::= { s530 1036 }
+
+s530UserTrap1037 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1037."
+ ::= { s530 1037 }
+
+s530UserTrap1038 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1038."
+ ::= { s530 1038 }
+
+s530UserTrap1039 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1039."
+ ::= { s530 1039 }
+
+s530UserTrap1040 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1040."
+ ::= { s530 1040 }
+
+s530UserTrap1041 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1041."
+ ::= { s530 1041 }
+
+s530UserTrap1042 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1042."
+ ::= { s530 1042 }
+
+s530UserTrap1043 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1043."
+ ::= { s530 1043 }
+
+s530UserTrap1044 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1044."
+ ::= { s530 1044 }
+
+s530UserTrap1045 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1045."
+ ::= { s530 1045 }
+
+s530UserTrap1046 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1046."
+ ::= { s530 1046 }
+
+s530UserTrap1047 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1047."
+ ::= { s530 1047 }
+
+s530UserTrap1048 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1048."
+ ::= { s530 1048 }
+
+s530UserTrap1049 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1049."
+ ::= { s530 1049 }
+
+s530UserTrap1050 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1050."
+ ::= { s530 1050 }
+
+s530UserTrap1051 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1051."
+ ::= { s530 1051 }
+
+s530UserTrap1052 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1052."
+ ::= { s530 1052 }
+
+s530UserTrap1053 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1053."
+ ::= { s530 1053 }
+
+s530UserTrap1054 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1054."
+ ::= { s530 1054 }
+
+s530UserTrap1055 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1055."
+ ::= { s530 1055 }
+
+s530UserTrap1056 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1056."
+ ::= { s530 1056 }
+
+s530UserTrap1057 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1057."
+ ::= { s530 1057 }
+
+s530UserTrap1058 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1058."
+ ::= { s530 1058 }
+
+s530UserTrap1059 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1059."
+ ::= { s530 1059 }
+
+s530UserTrap1060 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1060."
+ ::= { s530 1060 }
+
+s530UserTrap1061 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1061."
+ ::= { s530 1061 }
+
+s530UserTrap1062 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1062."
+ ::= { s530 1062 }
+
+s530UserTrap1063 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1063."
+ ::= { s530 1063 }
+
+s530UserTrap1064 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1064."
+ ::= { s530 1064 }
+
+s530UserTrap1065 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1065."
+ ::= { s530 1065 }
+
+s530UserTrap1066 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1066."
+ ::= { s530 1066 }
+
+s530UserTrap1067 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1067."
+ ::= { s530 1067 }
+
+s530UserTrap1068 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1068."
+ ::= { s530 1068 }
+
+s530UserTrap1069 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1069."
+ ::= { s530 1069 }
+
+s530UserTrap1070 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1070."
+ ::= { s530 1070 }
+
+s530UserTrap1071 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1071."
+ ::= { s530 1071 }
+
+s530UserTrap1072 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1072."
+ ::= { s530 1072 }
+
+s530UserTrap1073 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1073."
+ ::= { s530 1073 }
+
+s530UserTrap1074 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1074."
+ ::= { s530 1074 }
+
+s530UserTrap1075 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1075."
+ ::= { s530 1075 }
+
+s530UserTrap1076 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1076."
+ ::= { s530 1076 }
+
+s530UserTrap1077 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1077."
+ ::= { s530 1077 }
+
+s530UserTrap1078 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1078."
+ ::= { s530 1078 }
+
+s530UserTrap1079 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1079."
+ ::= { s530 1079 }
+
+s530UserTrap1080 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1080."
+ ::= { s530 1080 }
+
+s530UserTrap1081 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1081."
+ ::= { s530 1081 }
+
+s530UserTrap1082 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1082."
+ ::= { s530 1082 }
+
+s530UserTrap1083 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1083."
+ ::= { s530 1083 }
+
+s530UserTrap1084 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1084."
+ ::= { s530 1084 }
+
+s530UserTrap1085 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1085."
+ ::= { s530 1085 }
+
+s530UserTrap1086 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1086."
+ ::= { s530 1086 }
+
+s530UserTrap1087 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1087."
+ ::= { s530 1087 }
+
+s530UserTrap1088 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1088."
+ ::= { s530 1088 }
+
+s530UserTrap1089 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1089."
+ ::= { s530 1089 }
+
+s530UserTrap1090 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1090."
+ ::= { s530 1090 }
+
+s530UserTrap1091 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1091."
+ ::= { s530 1091 }
+
+s530UserTrap1092 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1092."
+ ::= { s530 1092 }
+
+s530UserTrap1093 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1093."
+ ::= { s530 1093 }
+
+s530UserTrap1094 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1094."
+ ::= { s530 1094 }
+
+s530UserTrap1095 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1095."
+ ::= { s530 1095 }
+
+s530UserTrap1096 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1096."
+ ::= { s530 1096 }
+
+s530UserTrap1097 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1097."
+ ::= { s530 1097 }
+
+s530UserTrap1098 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1098."
+ ::= { s530 1098 }
+
+s530UserTrap1099 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1099."
+ ::= { s530 1099 }
+
+s530UserTrap1100 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1100."
+ ::= { s530 1100 }
+
+s530UserTrap1101 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1101."
+ ::= { s530 1101 }
+
+s530UserTrap1102 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1102."
+ ::= { s530 1102 }
+
+s530UserTrap1103 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1103."
+ ::= { s530 1103 }
+
+s530UserTrap1104 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1104."
+ ::= { s530 1104 }
+
+s530UserTrap1105 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1105."
+ ::= { s530 1105 }
+
+s530UserTrap1106 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1106."
+ ::= { s530 1106 }
+
+s530UserTrap1107 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1107."
+ ::= { s530 1107 }
+
+s530UserTrap1108 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1108."
+ ::= { s530 1108 }
+
+s530UserTrap1109 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1109."
+ ::= { s530 1109 }
+
+s530UserTrap1110 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1110."
+ ::= { s530 1110 }
+
+s530UserTrap1111 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1111."
+ ::= { s530 1111 }
+
+s530UserTrap1112 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1112."
+ ::= { s530 1112 }
+
+s530UserTrap1113 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1113."
+ ::= { s530 1113 }
+
+s530UserTrap1114 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1114."
+ ::= { s530 1114 }
+
+s530UserTrap1115 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1115."
+ ::= { s530 1115 }
+
+s530UserTrap1116 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1116."
+ ::= { s530 1116 }
+
+s530UserTrap1117 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1117."
+ ::= { s530 1117 }
+
+s530UserTrap1118 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1118."
+ ::= { s530 1118 }
+
+s530UserTrap1119 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1119."
+ ::= { s530 1119 }
+
+s530UserTrap1120 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1120."
+ ::= { s530 1120 }
+
+s530UserTrap1121 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1121."
+ ::= { s530 1121 }
+
+s530UserTrap1122 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1122."
+ ::= { s530 1122 }
+
+s530UserTrap1123 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1123."
+ ::= { s530 1123 }
+
+s530UserTrap1124 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1124."
+ ::= { s530 1124 }
+
+s530UserTrap1125 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1125."
+ ::= { s530 1125 }
+
+s530UserTrap1126 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1126."
+ ::= { s530 1126 }
+
+s530UserTrap1127 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1127."
+ ::= { s530 1127 }
+
+s530UserTrap1128 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1128."
+ ::= { s530 1128 }
+
+s530UserTrap1129 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1129."
+ ::= { s530 1129 }
+
+s530UserTrap1130 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1130."
+ ::= { s530 1130 }
+
+s530UserTrap1131 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1131."
+ ::= { s530 1131 }
+
+s530UserTrap1132 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1132."
+ ::= { s530 1132 }
+
+s530UserTrap1133 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1133."
+ ::= { s530 1133 }
+
+s530UserTrap1134 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1134."
+ ::= { s530 1134 }
+
+s530UserTrap1135 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1135."
+ ::= { s530 1135 }
+
+s530UserTrap1136 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1136."
+ ::= { s530 1136 }
+
+s530UserTrap1137 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1137."
+ ::= { s530 1137 }
+
+s530UserTrap1138 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1138."
+ ::= { s530 1138 }
+
+s530UserTrap1139 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1139."
+ ::= { s530 1139 }
+
+s530UserTrap1140 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1140."
+ ::= { s530 1140 }
+
+s530UserTrap1141 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1141."
+ ::= { s530 1141 }
+
+s530UserTrap1142 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1142."
+ ::= { s530 1142 }
+
+s530UserTrap1143 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1143."
+ ::= { s530 1143 }
+
+s530UserTrap1144 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1144."
+ ::= { s530 1144 }
+
+s530UserTrap1145 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1145."
+ ::= { s530 1145 }
+
+s530UserTrap1146 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1146."
+ ::= { s530 1146 }
+
+s530UserTrap1147 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1147."
+ ::= { s530 1147 }
+
+s530UserTrap1148 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1148."
+ ::= { s530 1148 }
+
+s530UserTrap1149 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1149."
+ ::= { s530 1149 }
+
+s530UserTrap1150 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1150."
+ ::= { s530 1150 }
+
+s530UserTrap1151 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1151."
+ ::= { s530 1151 }
+
+s530UserTrap1152 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1152."
+ ::= { s530 1152 }
+
+s530UserTrap1153 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1153."
+ ::= { s530 1153 }
+
+s530UserTrap1154 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1154."
+ ::= { s530 1154 }
+
+s530UserTrap1155 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1155."
+ ::= { s530 1155 }
+
+s530UserTrap1156 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1156."
+ ::= { s530 1156 }
+
+s530UserTrap1157 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1157."
+ ::= { s530 1157 }
+
+s530UserTrap1158 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1158."
+ ::= { s530 1158 }
+
+s530UserTrap1159 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1159."
+ ::= { s530 1159 }
+
+s530UserTrap1160 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1160."
+ ::= { s530 1160 }
+
+s530UserTrap1161 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1161."
+ ::= { s530 1161 }
+
+s530UserTrap1162 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1162."
+ ::= { s530 1162 }
+
+s530UserTrap1163 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1163."
+ ::= { s530 1163 }
+
+s530UserTrap1164 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1164."
+ ::= { s530 1164 }
+
+s530UserTrap1165 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1165."
+ ::= { s530 1165 }
+
+s530UserTrap1166 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1166."
+ ::= { s530 1166 }
+
+s530UserTrap1167 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1167."
+ ::= { s530 1167 }
+
+s530UserTrap1168 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1168."
+ ::= { s530 1168 }
+
+s530UserTrap1169 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1169."
+ ::= { s530 1169 }
+
+s530UserTrap1170 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1170."
+ ::= { s530 1170 }
+
+s530UserTrap1171 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1171."
+ ::= { s530 1171 }
+
+s530UserTrap1172 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1172."
+ ::= { s530 1172 }
+
+s530UserTrap1173 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1173."
+ ::= { s530 1173 }
+
+s530UserTrap1174 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1174."
+ ::= { s530 1174 }
+
+s530UserTrap1175 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1175."
+ ::= { s530 1175 }
+
+s530UserTrap1176 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1176."
+ ::= { s530 1176 }
+
+s530UserTrap1177 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1177."
+ ::= { s530 1177 }
+
+s530UserTrap1178 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1178."
+ ::= { s530 1178 }
+
+s530UserTrap1179 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1179."
+ ::= { s530 1179 }
+
+s530UserTrap1180 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1180."
+ ::= { s530 1180 }
+
+s530UserTrap1181 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1181."
+ ::= { s530 1181 }
+
+s530UserTrap1182 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1182."
+ ::= { s530 1182 }
+
+s530UserTrap1183 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1183."
+ ::= { s530 1183 }
+
+s530UserTrap1184 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1184."
+ ::= { s530 1184 }
+
+s530UserTrap1185 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1185."
+ ::= { s530 1185 }
+
+s530UserTrap1186 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1186."
+ ::= { s530 1186 }
+
+s530UserTrap1187 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1187."
+ ::= { s530 1187 }
+
+s530UserTrap1188 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1188."
+ ::= { s530 1188 }
+
+s530UserTrap1189 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1189."
+ ::= { s530 1189 }
+
+s530UserTrap1190 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1190."
+ ::= { s530 1190 }
+
+s530UserTrap1191 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1191."
+ ::= { s530 1191 }
+
+s530UserTrap1192 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1192."
+ ::= { s530 1192 }
+
+s530UserTrap1193 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1193."
+ ::= { s530 1193 }
+
+s530UserTrap1194 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1194."
+ ::= { s530 1194 }
+
+s530UserTrap1195 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1195."
+ ::= { s530 1195 }
+
+s530UserTrap1196 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1196."
+ ::= { s530 1196 }
+
+s530UserTrap1197 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1197."
+ ::= { s530 1197 }
+
+s530UserTrap1198 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1198."
+ ::= { s530 1198 }
+
+s530UserTrap1199 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1199."
+ ::= { s530 1199 }
+
+END
diff --git a/MIBS/asentria/SITEBOSS-550-STD-MIB b/MIBS/asentria/SITEBOSS-550-STD-MIB
new file mode 100644
index 0000000..7c6f742
--- /dev/null
+++ b/MIBS/asentria/SITEBOSS-550-STD-MIB
@@ -0,0 +1,25637 @@
+-- SiteBoss 550 MIB
+
+-- v 4.66 Mar 8 2019
+
+-- Copyright (c) 2019 by Asentria Corporation. All rights reserved.
+
+
+SITEBOSS-550-STD-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ DisplayString
+ FROM SNMPv2-TC
+ IpAddress, TimeTicks, Integer32,
+ MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
+ FROM SNMPv2-SMI
+ asentria
+ FROM ASENTRIA-ROOT-MIB;
+
+--***************************************************************************************
+--MODULE IDENTITY
+--***************************************************************************************
+
+ s550 MODULE-IDENTITY
+ LAST-UPDATED "201903081530Z"
+ ORGANIZATION "Asentria Corporation"
+ CONTACT-INFO
+ "Phone: 206-344-8800
+ Fax: 206-344-2116
+ Email: support@asentria.com"
+ DESCRIPTION
+ "MIB module for managing Asentria SiteBoss 550"
+
+ REVISION "201903081530Z"
+ DESCRIPTION
+ "-v4.66
+ -Add objects for Power Meter line-to-line voltage (OMX-2143) and modified OID numbering for ACMON.
+ -Applicable since unit version 2.11.760."
+
+
+ REVISION "201902111345Z"
+ DESCRIPTION
+ "-v4.65
+ -Added objects for Site Security (OMX-2021).
+ -Applicable since unit version 2.11.760."
+
+ REVISION "201710311049Z"
+ DESCRIPTION
+ "-v4.64
+ -Added objects for Bard HVAC controller (OMX-1852).
+ -Applicable since unit version 2.11.550."
+
+ REVISION "201705251028Z"
+ DESCRIPTION
+ "-v4.63
+ -Added trap 545 and 548 to the mibs
+ -Applicable since unit version 2.11.500."
+
+ REVISION "201704260945Z"
+ DESCRIPTION
+ "-v4.62
+ -Added ACMON Alarm datetime to the mibs
+ -Applicable since unit version 2.11.490."
+
+ REVISION "201603160850Z"
+ DESCRIPTION
+ "-v4.61
+ -Fixed missing IP Camera trap notifications
+ -Applicable since unit version 2.11.210."
+
+ REVISION "201603150500Z"
+ DESCRIPTION
+ "-v4.60
+ -Replace existing sensor .type setting with new system .group
+ -Added Objects espcCCGroup, espcTempGroup, espcHumidGroup,
+ espcAIGroup espcOutputGroup
+ -Applicable since unit version 2.11.210."
+
+
+ REVISION "201601070459Z"
+ DESCRIPTION
+ "-v4.59
+ -Added Event Sensor Alias and Class OID for event states.
+ -Added Fuel Sensor Fuel Type.
+ -Applicable since unit version 2.11.140."
+
+
+ REVISION "201510290458Z"
+ DESCRIPTION
+ "-v4.58
+ -Allow read access for battery backup - percent charge and running
+ status.
+ -Add trap for power up/down or running on battery/main
+ -Applicable since unit version 2.10.930."
+
+ REVISION "201504030457Z"
+ DESCRIPTION
+ "-v4.57
+ -Allow read access for serial number, product name, software version
+ -Add trap for General Sensor Unresponsive (OMX-1257)
+ -Applicable since unit version 2.10.700."
+
+ REVISION "201503200456Z"
+ DESCRIPTION
+ "-v4.56
+ -Removed non-essential Bard settings (OMX-1203).
+ -Removed wirelessPIN and scSecret objects (OMX-1064).
+ -Added HVAC status and settings objects.
+ -Added ACDM wiegand point object.
+ -Applicable since unit version 2.10.670."
+
+ REVISION "201412110455Z"
+ DESCRIPTION
+ "-v4.55
+ -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
+ -Added missing ipv6DefaultRouter object (OMX-1175).
+ -Applicable since unit version 2.10.580."
+
+ REVISION "201410160454Z"
+ DESCRIPTION
+ "-v4.54
+ -Added espcAIDisplayFormat object (OMX-1112).
+ -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201410030453Z"
+ DESCRIPTION
+ "-v4.53
+ -Changed analog input objects from Integer32 to DisplayString.
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201409100452Z"
+ DESCRIPTION
+ "-v4.52
+ -Added dnp3 and telemetry branches (OMX-454).
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201408140451Z"
+ DESCRIPTION
+ "-v4.51
+ -Fixed description for wirelessConnIP objects (OMX-1061).
+ -Applicable since unit version 2.10.390."
+
+ REVISION "201407030450Z"
+ DESCRIPTION
+ "-v4.50
+ -Fixed wirelessIdleTimeout (OMX-1037).
+ -Fixed CPE status objects (OMX-1036).
+ -Applicable since unit version 2.10.390."
+
+ REVISION "201406240449Z"
+ DESCRIPTION
+ "-v4.49
+ -Fixed CPE status objects.
+ -Applicable since unit version 2.10.340."
+
+ REVISION "201406170448Z"
+ DESCRIPTION
+ "-v4.48
+ -Added various missing objects (OMX-751).
+ -Added CPE objects (OMX-162).
+ -Added ACDM objects (OMX-683).
+ -Applicable since unit version 2.10.340."
+
+ REVISION "201404110447Z"
+ DESCRIPTION
+ "-v4.47
+ -Clarified relay and power output function and documentation (OMX-926).
+ -Applicable since unit version 2.10.300."
+
+ REVISION "201401170146Z"
+ DESCRIPTION
+ "-v4.46
+ -Added IPv6 objects (OMX-705).
+ -Added power distribution objects (powerDistributionStatus branch) (OMX-708).
+ -Fixed ipRestrictionMask wrong type (OMX-743).
+ -Added ftpPushPermissions (OMX-737).
+ -Added snmpProxy objects (OMX-747).
+ -Applicable since unit version 2.10.150."
+
+ REVISION "201312160445Z"
+ DESCRIPTION
+ "-v4.45
+ -Changed evHVACStatus branch OIDs (OMX-702).
+ -Applicable since unit version 2.10.130."
+
+ REVISION "201312040444Z"
+ DESCRIPTION
+ "-v4.44
+ -Added fsGenEnable (OMX-661).
+ -Applicable since unit version 2.10.110."
+
+ REVISION "201310300443Z"
+ DESCRIPTION
+ "-v4.43
+ -Added genSetRelayTable for multiple genset ignition relays (OMX-577).
+ -Added genSetCCDelay object (OMX-589).
+ -Added webXMLProxy branch (OMX-629).
+ -Applicable since unit version 2.09.625."
+
+ REVISION "201310040442Z"
+ DESCRIPTION
+ "-v4.42
+ -Added objects for Emerson Vortex Power System (OMX-578).
+ -Applicable since unit version 2.09.624."
+
+ REVISION "201309260441Z"
+ DESCRIPTION
+ "-v4.41
+ -Added objects for Bard HVAC controller (OMX-563).
+ -Applicable since unit version 2.09.623."
+
+ REVISION "201308010440Z"
+ DESCRIPTION
+ "-v4.40
+ -Added missing trapEventTypeNumber available values in description (OMX-437).
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201307170439Z"
+ DESCRIPTION
+ "-v4.39
+ -Corrected snmpPBufferAllPeriod object.
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201307020438Z"
+ DESCRIPTION
+ "-v4.38
+ -Added snmpPoll objects (OMX-394).
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201306120437Z"
+ DESCRIPTION
+ "-v4.37
+ -Renamed EX10 to Ethernet Expansion (OMX-364)
+ -Applicable since unit version 2.09.510."
+
+ REVISION "201305280436Z"
+ DESCRIPTION
+ "-v4.36
+ -Fixed incorrect SYNTAX for sysCharMask (OMX-328).
+ -Added evGlobal branch (OMX-228).
+ -Applicable since unit version 2.09.500."
+
+ REVISION "201305100435Z"
+ DESCRIPTION
+ "-v4.35
+ -Fixed incorrect SYNTAX statements for various objects (OMX-314).
+ -Applicable since unit version 2.09.380."
+
+ REVISION "201304100434Z"
+ DESCRIPTION
+ "-v4.34
+ -Added non-weekly job scheduling objects (OMX-252).
+ -Applicable since unit version 2.09.310."
+
+ REVISION "201303150433Z"
+ DESCRIPTION
+ "-v4.33
+ -Renamed sysLocation branch to sysLoc (OMX-198).
+ -Applicable since unit version 2.09.240."
+
+ REVISION "201303140432Z"
+ DESCRIPTION
+ "-v4.32
+ -Added snmpProxy branch (OMX-190).
+ -Applicable since unit version 2.09.280."
+
+ REVISION "201302060431Z"
+ DESCRIPTION
+ "-v4.31
+ -Added ex10 branch.
+ -Renamed telnet* objects.
+ -Applicable since unit version 2.09.240."
+
+ REVISION "201301140430Z"
+ DESCRIPTION
+ "-v4.30
+ -Added evReset branch and associated notification (OMX-83).
+ -Applicable since unit version 2.09.220."
+
+ REVISION "201211190429Z"
+ DESCRIPTION
+ "-v4.29
+ -Added sysFileTransfer and sysUpdate objects. (BN 4632)
+ -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)
+ -Applicable since unit version 2.09.120."
+
+ REVISION "201208220428Z"
+ DESCRIPTION
+ "-v4.28
+ -Added additional AC power monitor items."
+
+ REVISION "201208020427Z"
+ DESCRIPTION
+ "-v4.27
+ -Removed non-weekly job schedule objects."
+
+ REVISION "201206120425Z"
+ DESCRIPTION
+ "-v4.25
+ -Removed user credentials objects."
+
+ REVISION "201205010424Z"
+ DESCRIPTION
+ "-v4.24
+ -Added object for location.
+ -Fixed objects for Generator Exercising Non-Start event."
+
+ REVISION "201204300423Z"
+ DESCRIPTION
+ "-v4.23
+ -Added objects for fuel sensor sudden/slow change."
+
+ REVISION "201204120422Z"
+ DESCRIPTION
+ "-v4.22
+ -Added objects for job scheduling and generator exercising."
+
+ REVISION "201204090421Z"
+ DESCRIPTION
+ "-v4.21
+ -Added eth2WanRoutingEnable object."
+
+ REVISION "201204050420Z"
+ DESCRIPTION
+ "-v4.20
+ -Added combined eventsensor status objects."
+
+ REVISION "201203060419Z"
+ DESCRIPTION
+ "-v4.19
+ -Added objects and trap definitions for fuel sensor and AC power monitor."
+
+ REVISION "201201160902Z"
+ DESCRIPTION
+ "-v4.18
+ -Jumped to 4.xx Asentria version series. The version 4
+ series officially may improve compatibility with certain
+ NMS installations by grouping all notifications in a
+ dedicated branch.
+ -Added stockScriptTrap notification definition."
+
+ REVISION "201109150900Z"
+ DESCRIPTION
+ "-v1.17
+ -Moved notification definitions to dedicated branch."
+
+ REVISION "201108080900Z"
+ DESCRIPTION
+ "-v1.16
+ -Added s550StockOutputTrap notification definition."
+
+ REVISION "201108010900Z"
+ DESCRIPTION
+ "-v1.15
+ -Added evMgmtReprocess object."
+
+ REVISION "201107080900Z"
+ DESCRIPTION
+ "-v1.14
+ -Added wirelessModemStatus branch."
+
+ REVISION "201101050900Z"
+ DESCRIPTION
+ "-v1.13
+ -Added espcCCNormalThreshold object."
+
+ REVISION "201011030900Z"
+ DESCRIPTION
+ "-v1.12
+ -Changed deadband, threshold, and current values for temperature
+ sensors from integer to floating-point type. This means the
+ SNMP object type for the temperature settings (deadbands and
+ thresholds) changed from Integer32 to DisplayString.
+ -Fixed bug where SNMP integer range defined in the MIB for
+ trapIncludedValue was 16-bit instead of 32-bit."
+
+ REVISION "201008240900Z"
+ DESCRIPTION
+ "-v1.11
+ -Fixed bug where some stock traps had too few varbinds declared.
+ -Removed useless trap definitions."
+
+ REVISION "201003160900Z"
+ DESCRIPTION
+ "-v1.10
+ -Removed useless objects consoleInlineHsk, consoleBaud, consoleFormat, consoleHsk."
+
+ REVISION "201001190900Z"
+ DESCRIPTION
+ "-v1.09
+ -Increased range for esPointValueInt"
+
+ REVISION "200811210900Z"
+ DESCRIPTION
+ "-v1.08
+ -Added scripting variable objects."
+
+ REVISION "200811120900Z"
+ DESCRIPTION
+ "-v1.07
+ -Corrected comments for stock trap definitions."
+
+ REVISION "200806090900Z"
+ DESCRIPTION
+ "-v1.06
+ -Added sysLocation branch.
+ -Updated phone numbers in contact info block."
+
+ REVISION "200806021100Z"
+ DESCRIPTION
+ "-v1.05
+ -Added SitePath CPE routing authorization requested stock trap."
+
+ REVISION "200805151500Z"
+ DESCRIPTION
+ "-v1.04
+ -Added pager settings"
+
+ REVISION "200805081426Z"
+ DESCRIPTION
+ "-v1.03
+ -Fixed issue where commented OIDs used wrong module identity number"
+
+ REVISION "200804221652Z"
+ DESCRIPTION
+ "-v1.02
+ -Added missing wireless objects
+ -Removed wirelessBaud object which broke mib walk
+ -Fixed issue where snmpNotificationTx branch was defined wrong."
+
+ REVISION "200803211650Z"
+ DESCRIPTION
+ "-v1.01
+ -Added missing CPEDown/VPNGDow notification definitions"
+
+ REVISION "200712070030Z"
+ DESCRIPTION
+ "-v1.00
+ -Branched new MIB off of SiteBoss 570 MIB"
+
+ ::= { asentria 10 }
+ --1.3.6.1.4.1.3052.10
+
+
+--***************************************************************************************
+--Concise MIB View: Top Level Branches
+--***************************************************************************************
+
+-- status .1
+-- eventSensorStatus .1.1
+-- esPointTable .1.1.1
+-- dataEventStatus .1.2
+-- deStatusTable .1.2.1
+-- modemStatus .1.3
+-- modemCLIDLogTable .1.4
+-- powerDistributionStatus .1.5
+-- fuelSensorStatus .1.6
+-- fsStatusTable .1.6.1
+-- wirelessModemStatus .1.7
+-- acPowerMonitorStatus .1.8
+-- acpmStatusTable .1.8.1
+-- evHVACStatus .1.11
+-- evHVACStatusBard .1.11.2
+-- evHVACStatusAsentria .1.11.3
+-- evHVACStatusAirsys .1.11.4
+-- backupBattStatus .1.12
+-- liBattStatus .1.12.1
+-- config .2
+-- eventSensorBasics .2.1
+-- esNumberEventSensors .2.1.1
+-- esTable .2.1.2
+-- esNewSensors .2.1.3
+-- eventSensorPointConfig .2.2
+-- esPointConfigTempTable .2.2.1
+-- esPointConfigCCTable .2.2.2
+-- esPointConfigHumidTable .2.2.3
+-- esPointConfigAITable .2.2.5
+-- esPointConfigOutputTable .2.2.6
+-- serialPorts .2.3
+-- numberPorts .2.3.1
+-- portConfigTable .2.3.2
+-- network .2.4
+-- interface .2.4.1
+-- defaultRouter .2.4.2
+-- dnsTable .2.4.3
+-- hostname .2.4.4
+-- hostTable .2.4.5
+-- ncpDuplex .2.4.6
+-- ncpTimeout .2.4.7
+-- snmp .2.4.8
+-- ftpPush .2.4.9
+-- ppp .2.4.10
+-- routing .2.4.11
+-- netSecurity .2.4.12
+-- rts .2.4.13
+-- trap .2.4.14
+-- routeTest .2.4.15
+-- gprs .2.4.16
+-- email .2.4.17
+-- netAdvanced .2.4.18
+-- web .2.4.19
+-- ethExpan .2.4.20
+-- ipv6 .2.4.21
+-- cpe .2.4.22
+-- dnp3 .2.4.23
+-- modem .2.5
+-- time .2.8
+-- clock .2.8.1
+-- console .2.10
+-- unitSecurity .2.11
+-- secCore .2.11.1
+-- secUserTable .2.11.2
+-- secFactory .2.11.3
+-- secSSH .2.11.4
+-- secVPN .2.11.5
+-- event .2.12
+-- evCore .2.12.1
+-- evData .2.12.2
+-- evNoData1 .2.12.3
+-- evNoData2 .2.12.4
+-- evSched1 .2.12.5
+-- evSched2 .2.12.6
+-- evShskLowTable .2.12.7
+-- evShskHighTable .2.12.8
+-- evNoSensor .2.12.9
+-- fuelSensor .2.12.11
+-- fuelSensorGeneralTable .2.12.11.1
+-- fuelSensorTankTable .2.12.11.2
+-- fuelSensorCustomTankTable .2.12.11.3
+-- fuelSensorVolumeTable .2.12.11.4
+-- fuelSensorDisconnectTable .2.12.11.5
+-- fuelSensorSuddenChangeTable .2.12.11.6
+-- fuelSensorSlowChangeTable .2.12.11.7
+-- acPowerMonitor .2.12.12
+-- evReset .2.12.16
+-- evGlobal .2.12.18
+-- evHVAC .2.12.19
+-- evHVACGeneral .2.12.19.1
+-- evHVACBard .2.12.19.2
+-- evHVACAsentria .2.12.19.3
+-- evHVACAirsys .2.12.19.4
+-- evEvps .2.12.20
+-- accessControl .2.12.21
+-- telemetry .2.12.22
+-- siteSecurity .2.12.23
+-- action .2.14
+-- actionCallNumberTable .2.14.1
+-- actionPagerTable .2.14.2
+-- actionSched .2.14.3
+-- actionAsentria .2.14.4
+-- actionHostTable .2.14.6
+-- actionEmailTable .2.14.7
+-- actionParseError .2.14.8
+-- sys .2.16
+-- sysTime .2.16.1
+-- sysPT .2.16.2
+-- sysMTU .2.16.3
+-- sysAnswerString .2.16.4
+-- sysEventFileID .2.16.6
+-- sysEscapeCharacter .2.16.7
+-- sysTimeStamp .2.16.8
+-- sysLog .2.16.9
+-- sysCRDB .2.16.10
+-- sysCharMask .2.16.11
+-- sysPrompt .2.16.12
+-- sysBootStatus .2.16.13
+-- sysLoc .2.16.14
+-- sysAssetMgmt .2.16.15
+-- sysFileTransfer .2.16.17
+-- sysUpdate .2.16.18
+-- auditLog .2.17
+-- scripting .2.18
+-- scrGlobalEnable .2.18.1
+-- scrDTRCtrlPortEnableTable .2.18.2
+-- scrTable .2.18.3
+-- scrVolatileStringTable .2.18.4
+-- scrVolatileIntTable .2.18.5
+-- scrNonVolatileStringTable .2.18.6
+-- scrNonVolatileIntTable .2.18.7
+-- generator .2.19
+-- genSet .2.19.1
+-- genSetRelay .2.19.1.2
+-- genSetCc .2.19.1.3
+-- genRun .2.19.2
+-- genRunNonstartEvent .2.19.2.7
+-- calendar .2.20
+-- productIds .3
+-- siteName 3.1
+-- thisProduct .3.2
+-- stockTrapString .3.3
+-- trapEventTypeNumber .3.4
+-- trapEventTypeName .3.5
+-- trapIncludedValue .3.6
+-- trapIncludedString .3.7
+-- trapTypeString .3.8
+-- trapEventClassNumber .3.9
+-- trapEventClassName .3.10
+-- keyInterface .4.0
+
+--***************************************************************************************
+--Complete MIB View: All Objects
+--***************************************************************************************
+
+-- status .1
+-- eventSensorStatus .1.1
+-- esPointTable .1.1.1
+-- esPointEntry .1.1.1.1
+-- esIndexES .1.1.1.1.1
+-- esIndexPC .1.1.1.1.2
+-- esIndexPoint .1.1.1.1.3
+-- esPointName .1.1.1.1.4
+-- esPointInEventState .1.1.1.1.5
+-- esPointValueInt .1.1.1.1.6
+-- esPointValueStr .1.1.1.1.7
+-- esPointTimeLastChange .1.1.1.1.8
+-- esPointTimetickLastChange .1.1.1.1.9
+-- esPointAliasValueStr .1.1.1.1.10
+-- esPointClassValueStr .1.1.1.1.11
+-- dataEventStatus .1.2
+-- deStatusTable .1.2.1
+-- deStatusEntry .1.2.1.1
+-- deStatusIndex .1.2.1.1.1
+-- deStatusName .1.2.1.1.2
+-- deStatusCounter .1.2.1.1.3
+-- deStatusThreshold .1.2.1.1.4
+-- modemStatus .1.3
+-- modemCLIDLogTable .1.4
+-- modemCLIDLogEntry .1.4.1
+-- modemCLIDLogIndex .1.4.1.1
+-- modemCLIDLogNumber .1.4.1.2
+-- powerDistributionStatus .1.5
+-- pdConfig .1.5.1
+-- pdNextGen .1.5.4
+-- pdnTable .1.5.4.1
+-- pdnEntry .1.5.4.1.1
+-- pdnIndexPD .1.5.4.1.1.1
+-- pdnIndexOutput .1.5.4.1.1.2
+-- pdnConfig .1.5.4.1.1.3
+-- pdnMainCurrentInEventState .1.5.4.1.1.4
+-- pdnMainCurrentValue .1.5.4.1.1.5
+-- pdnMainCurrentValueStr .1.5.4.1.1.6
+-- pdnMainCurrentDeadband .1.5.4.1.1.7
+-- pdnMainCurrentVHighCurrent .1.5.4.1.1.8
+-- pdnMainCurrentHighCurrent .1.5.4.1.1.9
+-- pdnMainCurrentLowCurrent .1.5.4.1.1.10
+-- pdnMainCurrentVLowCurrent .1.5.4.1.1.11
+-- pdnMainVoltageInEventState .1.5.4.1.1.12
+-- pdnMainVoltageValue .1.5.4.1.1.13
+-- pdnMainVoltageValueStr .1.5.4.1.1.14
+-- pdnMainVoltageDeadband .1.5.4.1.1.15
+-- pdnMainVoltageVHighVoltage .1.5.4.1.1.16
+-- pdnMainVoltageHighVoltage .1.5.4.1.1.17
+-- pdnMainVoltageLowVoltage .1.5.4.1.1.18
+-- pdnMainVoltageVLowVoltage .1.5.4.1.1.19
+-- pdnMainPowerValue .1.5.4.1.1.20
+-- pdnMainPowerValueStr .1.5.4.1.1.21
+-- pdnOutputCurrentInEventState .1.5.4.1.1.22
+-- pdnOutputCurrentValue .1.5.4.1.1.23
+-- pdnOutputCurrentValueStr .1.5.4.1.1.24
+-- pdnOutputCurrentDeadband .1.5.4.1.1.25
+-- pdnOutputCurrentVHighCurrent .1.5.4.1.1.26
+-- pdnOutputCurrentHighCurrent .1.5.4.1.1.27
+-- pdnOutputCurrentLowCurrent .1.5.4.1.1.28
+-- pdnOutputCurrentVLowCurrent .1.5.4.1.1.29
+-- pdnOutputFuseInEventState .1.5.4.1.1.30
+-- pdnOutputFuseValueStr .1.5.4.1.1.31
+-- pdnMainCombinedStatus .1.5.4.1.1.32
+-- pdnOutputCombinedStatusBlock1 .1.5.4.1.1.33
+-- pdnOutputCombinedStatusBlock2 .1.5.4.1.1.34
+-- pdnDeviceCurrentValue .1.5.4.1.1.35
+-- pdnDeviceCurrentValueStr .1.5.4.1.1.36
+-- pdSystem .1.5.5
+-- pdSystemCurrent .1.5.5.1
+-- pdSystemPower .1.5.5.2
+-- fuelSensorStatus .1.6
+-- fsStatusTable .1.6.1
+-- fsStatusEntry .1.6.1.1
+-- fsStatusIndex .1.6.1.1.1
+-- fsStatusName .1.6.1.1.2
+-- fsStatusDeviceState .1.6.1.1.3
+-- fsStatusVolumeValueString .1.6.1.1.4
+-- fsStatusVolumePercentLevel .1.6.1.1.7
+-- fsStatusVolumeInEventState .1.6.1.1.8
+-- fsStatusCombined .1.6.1.1.9
+-- wirelessModemStatus .1.7
+-- wmsStatus .1.7.1
+-- wmsSignal .1.7.2
+-- wmsRSSI .1.7.3
+-- wmsBER .1.7.4
+-- wmsUpdated .1.7.5
+-- wmsRegistration .1.7.6
+-- wmsLAC .1.7.7
+-- wmsCellID .1.7.8
+-- wmsIMSI .1.7.9
+-- wmsPhnum .1.7.10
+-- wmsLocalIP .1.7.11
+-- wmsMgfID .1.7.12
+-- wmsModelID .1.7.13
+-- wmsIMEI .1.7.14
+-- wmsRevID .1.7.15
+-- wmsNetName .1.7.16
+-- wmsGPRSStatus .1.7.17
+-- wmsBand .1.7.18
+-- wmsChannel .1.7.19
+-- wmsCountryCode .1.7.20
+-- wmsNetCode .1.7.21
+-- wmsPLMNColor .1.7.22
+-- wmsBScolor .1.7.23
+-- wmsMpRACH .1.7.24
+-- wmsMinRxLevel .1.7.25
+-- wmsBaseCoeff .1.7.26
+-- wmsSIMStatus .1.7.27
+-- wmsICCID .1.7.28
+-- wmsModemType .1.7.29
+-- acPowerMonitorStatus .1.8
+-- acpmStatusTable .1.8.1
+-- acpmStatusEntry .1.8.1.1
+-- acpmsIndex .1.8.1.1.1
+-- acpmsName .1.8.1.1.2
+-- acpmsAvgVoltageValueStr .1.8.1.1.3
+-- acpmsAvgVoltageMinStr .1.8.1.1.4
+-- acpmsAvgVoltageMaxStr .1.8.1.1.5
+-- acpmsAvgVoltageAvgStr .1.8.1.1.6
+-- acpmsAvgVoltageInEventState .1.8.1.1.7
+-- acpmsVoltagePhaseAValueStr .1.8.1.1.8
+-- acpmsVoltagePhaseBValueStr .1.8.1.1.9
+-- acpmsVoltagePhaseCValueStr .1.8.1.1.10
+-- acpmsVoltageL1L2Value .1.8.1.1.11
+-- acpmsVoltageL2L3Value .1.8.1.1.12
+-- acpmsVoltageL3L1Value .1.8.1.1.13
+-- acpmsAvgCurrentValueStr .1.8.1.1.14
+-- acpmsAvgCurrentMinStr .1.8.1.1.15
+-- acpmsAvgCurrentMaxStr .1.8.1.1.16
+-- acpmsAvgCurrentAvgStr .1.8.1.1.17
+-- acpmsAvgCurrentInEventState .1.8.1.1.18
+-- acpmsCurrentPhaseAValueStr .1.8.1.1.19
+-- acpmsCurrentPhaseBValueStr .1.8.1.1.20
+-- acpmsCurrentPhaseCValueStr .1.8.1.1.21
+-- acpmsFreqValueStr .1.8.1.1.22
+-- acpmsFreqMinStr .1.8.1.1.23
+-- acpmsFreqMaxStr .1.8.1.1.24
+-- acpmsFreqAvgStr .1.8.1.1.25
+-- acpmsFreqInEventState .1.8.1.1.26
+-- acpmsTRPValueStr .1.8.1.1.27
+-- acpmsTRPMinStr .1.8.1.1.28
+-- acpmsTRPMaxStr .1.8.1.1.29
+-- acpmsTRPAvgStr .1.8.1.1.30
+-- acpmsTRPInEventState .1.8.1.1.31
+-- acpmsRPPhaseAValueStr .1.8.1.1.32
+-- acpmsRPPhaseBValueStr .1.8.1.1.33
+-- acpmsRPPhaseCValueStr .1.8.1.1.34
+-- acpmsCombined .1.8.1.1.35
+-- acpmsTPFValueStr .1.8.1.1.36
+-- acpmsTPFMinStr .1.8.1.1.37
+-- acpmsTPFMaxStr .1.8.1.1.38
+-- acpmsTPFAvgStr .1.8.1.1.39
+-- acpmsTPFInEventState .1.8.1.1.40
+-- acpmsPFPhaseAValueStr .1.8.1.1.41
+-- acpmsPFPhaseBValueStr .1.8.1.1.42
+-- acpmsPFPhaseCValueStr .1.8.1.1.43
+-- acpmsTRcPValueStr .1.8.1.1.44
+-- acpmsTRcPMinStr .1.8.1.1.45
+-- acpmsTRcPMaxStr .1.8.1.1.46
+-- acpmsTRcPAvgStr .1.8.1.1.47
+-- acpmsRcPPhaseAValueStr .1.8.1.1.48
+-- acpmsRcPPhaseBValueStr .1.8.1.1.49
+-- acpmsRcPPhaseCValueStr .1.8.1.1.50
+-- acpmsTAPValueStr .1.8.1.1.51
+-- acpmsTAPMinStr .1.8.1.1.52
+-- acpmsTAPMaxStr .1.8.1.1.53
+-- acpmsTAPAvgStr .1.8.1.1.54
+-- acpmsAPPhaseAValueStr .1.8.1.1.55
+-- acpmsAPPhaseBValueStr .1.8.1.1.56
+-- acpmsAPPhaseCValueStr .1.8.1.1.57
+-- acpmsTotalEnergyWh .1.8.1.1.58
+-- acpmsTotalEnergyVAR .1.8.1.1.59
+-- acpmsTotalEnergyVA .1.8.1.1.60
+-- acmpsAvgVoltageAlarmDatetime .1.8.1.1.61
+-- acmpsAvgCurrentAlarmDatetime .1.8.1.1.62
+-- acmpsFreqAlarmDatetime .1.8.1.1.63
+-- acmpsRealPowerAlarmDatetime .1.8.1.1.64
+-- acmpsPowerFactorAlarmDatetime .1.8.1.1.65
+-- evHVACStatus .1.11
+-- evHVACStatusBard .1.11.2
+-- evHVACStatusBardSystem1 .1.11.2.1
+-- evHVACStatusBardSystem1Stage1 .1.11.2.1.1
+-- evHVACStatusBardSystem1Stage1Cooling .1.11.2.1.1.1
+-- evHVACStatusBardSystem1Stage2 .1.11.2.1.2
+-- evHVACStatusBardSystem1Stage2Cooling .1.11.2.1.2.1
+-- evHVACStatusBardSystem1Blower .1.11.2.1.3
+-- evHVACStatusBardSystem1Heating .1.11.2.1.4
+-- evHVACStatusBardSystem1Economizer .1.11.2.1.5
+-- evHVACStatusBardSystem2 .1.11.2.2
+-- evHVACStatusBardSystem2Stage1 .1.11.2.2.1
+-- evHVACStatusBardSystem2Stage1Cooling .1.11.2.2.1.1
+-- evHVACStatusBardSystem2Stage2 .1.11.2.2.2
+-- evHVACStatusBardSystem2Stage2Cooling .1.11.2.2.2.1
+-- evHVACStatusBardSystem2Blower .1.11.2.2.3
+-- evHVACStatusBardSystem2Heating .1.11.2.2.4
+-- evHVACStatusBardSystem2Economizer .1.11.2.2.5
+-- evHVACStatusBardTempAvg .1.11.2.3
+-- evHVACStatusBardTempLocal .1.11.2.4
+-- evHVACStatusBardTempRemote .1.11.2.5
+-- evHVACStatusBardTempRemote1 .1.11.2.5.1
+-- evHVACStatusBardTempRemote2 .1.11.2.5.2
+-- evHVACStatusBardDehumidification .1.11.2.6
+-- evHVACStatusBardLEDs .1.11.2.7
+-- evHVACStatusBardLEDsCooling .1.11.2.7.1
+-- evHVACStatusBardLEDsCooling1 .1.11.2.7.1.1
+-- evHVACStatusBardLEDsCooling2 .1.11.2.7.1.2
+-- evHVACStatusBardLEDsCooling3 .1.11.2.7.1.3
+-- evHVACStatusBardLEDsCooling4 .1.11.2.7.1.4
+-- evHVACStatusBardLEDsHeating .1.11.2.7.2
+-- evHVACStatusBardLEDsHeating1 .1.11.2.7.2.1
+-- evHVACStatusBardLEDsHeating2 .1.11.2.7.2.2
+-- evHVACStatusBardLEDsHeating3 .1.11.2.7.2.3
+-- evHVACStatusBardLEDsHeating4 .1.11.2.7.2.4
+-- evHVACStatusBardLEDsDeHumid .1.11.2.7.3
+-- evHVACStatusBardLEDsDeHumid1 .1.11.2.7.3.1
+-- evHVACStatusBardGenerator .1.11.2.8
+-- evHVACStatusBardAlarmBoardState .1.11.2.9
+-- evHVACStatusBardAlarmStatus .1.11.2.10
+-- evHVACStatusBardASSystem1 .1.11.2.10.1
+-- evHVACStatusBardASSystem1PowerLoss .1.11.2.10.1.1
+-- evHVACStatusBardASSystem1Lockout .1.11.2.10.1.2
+-- evHVACStatusBardASSystem2 .1.11.2.10.2
+-- evHVACStatusBardASSystem2PowerLoss .1.11.2.10.2.1
+-- evHVACStatusBardASSystem2Lockout .1.11.2.10.2.2
+-- evHVACStatusBardASFire .1.11.2.10.3
+-- evHVACStatusBardASTemp .1.11.2.10.4
+-- evHVACStatusBardASTempLowAlarm .1.11.2.10.4.1
+-- evHVACStatusBardASTempHighAlarm .1.11.2.10.4.2
+-- evHVACStatusBardASTempVHighAlarm .1.11.2.10.4.3
+-- evHVACStatusBardASFailure .1.11.2.10.5
+-- evHVACStatusBardConnState .1.11.2.11
+-- evHVACStatusAsentria .1.11.3
+-- evHVACStatusAsentriaSequenceTable .1.11.3.1
+-- evHVACStatusAsentriaSequenceEntry .1.11.3.1.1
+-- evHVACStatusAsentriaSequenceIndex .1.11.3.1.1.1
+-- evHVACStatusAsentriaSeqVentTime .1.11.3.1.1.2
+-- evHVACStatusAsentriaSeqCoolTime .1.11.3.1.1.3
+-- evHVACStatusAsentriaSeqHeatTime .1.11.3.1.1.4
+-- evHVACStatusAsentriaSeqIdleTime .1.11.3.1.1.5
+-- evHVACStatusAsentriaUnitTable .1.11.3.2
+-- evHVACStatusAsentriaUnitEntry .1.11.3.2.1
+-- evHVACStatusAsentriaUnitIndex .1.11.3.2.1.1
+-- evHVACStatusAsentriaUnitState .1.11.3.2.1.2
+-- evHVACStatusAsentriaUnitVentTime .1.11.3.2.1.3
+-- evHVACStatusAsentriaUnitCoolTime .1.11.3.2.1.4
+-- evHVACStatusAsentriaUnitHeatTime .1.11.3.2.1.5
+-- evHVACStatusAsentriaUnitIdleTime .1.11.3.2.1.6
+-- evHVACStatusAsentriaBackupEvent .1.11.3.3
+-- evHVACStatusAsentriaFireEvent .1.11.3.4
+-- evHVACStatusAsentriaTemp .1.11.3.5
+-- evHVACStatusAsentriaTempOut .1.11.3.5.1
+-- evHVACStatusAsentriaTempIn .1.11.3.5.2
+-- evHVACStatusAsentriaHumid .1.11.3.6
+-- evHVACStatusAsentriaHumidOut .1.11.3.6.1
+-- evHVACStatusAsentriaHumidIn .1.11.3.6.2
+-- evHVACStatusAirsys .1.11.4
+-- evHVACStatusAirsysAlarm .1.11.4.1
+-- evHVACStatusAirsysAlarmUnitTable .1.11.4.1.1
+-- evHVACStatusAirsysAlarmUnitEntry .1.11.4.1.1.1
+-- evHVACStatusAirsysAlarmUnitIndex .1.11.4.1.1.1.1
+-- evHVACStatusAirsysAlarmUnitLowPress .1.11.4.1.1.1.2
+-- evHVACStatusAirsysAlarmUnitHighPress .1.11.4.1.1.1.3
+-- evHVACStatusAirsysAlarmUnitEvapFan .1.11.4.1.1.1.4
+-- evHVACStatusAirsysAlarmUnitDirty .1.11.4.1.1.1.5
+-- evHVACStatusAirsysAlarmUnitDamper .1.11.4.1.1.1.6
+-- evHVACStatusAirsysAlarmUnitSupProbe .1.11.4.1.1.1.7
+-- evHVACStatusAirsysAlarmSmokeFire .1.11.4.1.2
+-- evHVACStatusAirsysAlarmLowRoomTemp .1.11.4.1.3
+-- evHVACStatusAirsysAlarmHighRoomTemp .1.11.4.1.4
+-- evHVACStatusAirsysAlarmPower .1.11.4.1.5
+-- evHVACStatusAirsysAlarmpLAN .1.11.4.1.6
+-- evHVACStatusAirsysAlarmClock .1.11.4.1.7
+-- evHVACStatusAirsysAlarmHumidProbe .1.11.4.1.8
+-- evHVACStatusAirsysAlarmOutProbe .1.11.4.1.9
+-- evHVACStatusAirsysAlarmBothCompress .1.11.4.1.10
+-- evHVACStatusAirsysAlarmGenerator .1.11.4.1.11
+-- evHVACStatusAirsysAlarmConnection .1.11.4.1.12
+-- evHVACStatusAirsysAlarmInProbe1 .1.11.4.1.13
+-- evHVACStatusAirsysAlarmInProbe2 .1.11.4.1.14
+-- evHVACStatusAirsysTempOut .1.11.4.2
+-- evHVACStatusAirsysTempIn .1.11.4.3
+-- evHVACStatusAirsysTempInBackup .1.11.4.4
+-- evHVACStatusAirsysHumidIn .1.11.4.5
+-- evHVACStatusAirsysUnitTable .1.11.4.6
+-- evHVACStatusAirsysUnitEntry .1.11.4.6.1
+-- evHVACStatusAirsysUnitIndex .1.11.4.6.1.1
+-- evHVACStatusAirsysUnitTempSupply .1.11.4.6.1.2
+-- evHVACStatusAirsysUnitFanspeed .1.11.4.6.1.3
+-- evHVACStatusAirsysUnitFreeOpening .1.11.4.6.1.4
+-- evHVACStatusAirsysUnitStatus .1.11.4.6.1.5
+-- evHVACStatusAirsysUnitLocked .1.11.4.6.1.6
+-- evHVACStatusAirsysUnitCompressor .1.11.4.6.1.7
+-- evHVACStatusAirsysUnitHeater .1.11.4.6.1.8
+-- evHVACStatusAirsysURuntimeSupplyFan .1.11.4.6.1.9
+-- evHVACStatusAirsysURuntimeCompressor .1.11.4.6.1.10
+-- evHVACStatusAirsysURuntimeHeat .1.11.4.6.1.11
+-- evHVACStatusAirsysURuntimeFreeCooling .1.11.4.6.1.12
+-- evHVACStatusAirsysUCountSupplyFan .1.11.4.6.1.13
+-- evHVACStatusAirsysUCountCompressor .1.11.4.6.1.14
+-- evHVACStatusAirsysUCountHeat .1.11.4.6.1.15
+-- evHVACStatusAirsysUCountFreeCooling .1.11.4.6.1.16
+-- evHVACStatusAirsysDay .1.11.4.7
+-- evHVACStatusAirsysDate .1.11.4.8
+-- evHVACStatusAirsysTime .1.11.4.9
+-- evHVACStatusAirsysVersion .1.11.4.10
+-- backupBattStatus .1.12
+-- liBattStatus .1.12.1
+-- liBattPercentCharge .1.12.1.1
+-- liBattRunning .1.12.1.2
+-- config .2
+-- eventSensorBasics .2.1
+-- esNumberEventSensors .2.1.1
+-- esTable .2.1.2
+-- esEntry .2.1.2.1
+-- esIndex .2.1.2.1.1
+-- esName .2.1.2.1.2
+-- esID .2.1.2.1.3
+-- esNumberTempSensors .2.1.2.1.4
+-- esTempReportingMode .2.1.2.1.5
+-- esNumberCCs .2.1.2.1.6
+-- esCCReportingMode .2.1.2.1.7
+-- esNumberHumidSensors .2.1.2.1.8
+-- esHumidReportingMode .2.1.2.1.9
+-- esNumberNoiseSensors .2.1.2.1.10
+-- esNoiseReportingMode .2.1.2.1.11
+-- esNumberAirflowSensors .2.1.2.1.12
+-- esAirflowReportingMode .2.1.2.1.13
+-- esNumberAnalog .2.1.2.1.14
+-- esAnalogReportingMode .2.1.2.1.15
+-- esNumberOutputs .2.1.2.1.16
+-- esOutputReportingMode .2.1.2.1.17
+-- esTempCombinedStatus .2.1.2.1.18
+-- esCCCombinedStatusBlock1 .2.1.2.1.19
+-- esCCCombinedStatusBlock2 .2.1.2.1.20
+-- esCCCombinedStatusBlock3 .2.1.2.1.21
+-- esCCCombinedStatusBlock4 .2.1.2.1.22
+-- esCCCombinedStatusBlock5 .2.1.2.1.23
+-- esCCCombinedStatusBlock6 .2.1.2.1.24
+-- esCCCombinedStatusBlock7 .2.1.2.1.25
+-- esCCCombinedStatusBlock8 .2.1.2.1.26
+-- esHumidCombinedStatus .2.1.2.1.27
+-- esAnalogCombinedStatusBlock1 .2.1.2.1.28
+-- esAnalogCombinedStatusBlock2 .2.1.2.1.29
+-- esAnalogCombinedStatusBlock3 .2.1.2.1.30
+-- esAnalogCombinedStatusBlock4 .2.1.2.1.31
+-- esAnalogCombinedStatusBlock5 .2.1.2.1.32
+-- esAnalogCombinedStatusBlock6 .2.1.2.1.33
+-- esOutputCombinedStatusBlock1 .2.1.2.1.34
+-- esOutputCombinedStatusBlock2 .2.1.2.1.35
+-- esNewSensors .2.1.3
+-- eventSensorPointConfig .2.2
+-- esPointConfigTempTable .2.2.1
+-- esPointConfigTempEntry .2.2.1.1
+-- espcTempIndexES .2.2.1.1.1
+-- espcTempIndexPoint .2.2.1.1.2
+-- espcTempEnable .2.2.1.1.3
+-- espcTempScale .2.2.1.1.4
+-- espcTempDeadband .2.2.1.1.5
+-- espcTempVHighTemp .2.2.1.1.6
+-- espcTempVHighActions .2.2.1.1.7
+-- espcTempVHighTrapnum .2.2.1.1.8
+-- espcTempVHighClass .2.2.1.1.9
+-- espcTempHighTemp .2.2.1.1.10
+-- espcTempHighActions .2.2.1.1.11
+-- espcTempHighTrapnum .2.2.1.1.12
+-- espcTempHighClass .2.2.1.1.13
+-- espcTempNormalActions .2.2.1.1.14
+-- espcTempNormalTrapnum .2.2.1.1.15
+-- espcTempNormalClass .2.2.1.1.16
+-- espcTempLowTemp .2.2.1.1.17
+-- espcTempLowActions .2.2.1.1.18
+-- espcTempLowTrapnum .2.2.1.1.19
+-- espcTempLowClass .2.2.1.1.20
+-- espcTempVLowTemp .2.2.1.1.21
+-- espcTempVLowActions .2.2.1.1.22
+-- espcTempVLowTrapnum .2.2.1.1.23
+-- espcTempVLowClass .2.2.1.1.24
+-- espcTempGroup .2.2.1.1.25
+-- esPointConfigCCTable .2.2.2
+-- esPointConfigCCEntry .2.2.2.1
+-- espcCCIndexES .2.2.2.1.1
+-- espcCCIndexPoint .2.2.2.1.2
+-- espcCCEnable .2.2.2.1.3
+-- espcCCName .2.2.2.1.4
+-- espcCCEventState .2.2.2.1.5
+-- espcCCThreshold .2.2.2.1.6
+-- espcCCEventActions .2.2.2.1.7
+-- espcCCEventTrapnum .2.2.2.1.8
+-- espcCCEventClass .2.2.2.1.9
+-- espcCCNormalActions .2.2.2.1.10
+-- espcCCNormalTrapnum .2.2.2.1.11
+-- espcCCNormalClass .2.2.2.1.12
+-- espcCCAlarmAlias .2.2.2.1.13
+-- espcCCNormalAlias .2.2.2.1.14
+-- espcCCNormalThreshold .2.2.2.1.15
+-- espcCCOverrideGlobalReminder .2.2.2.1.16
+-- espcCCReminderInterval .2.2.2.1.17
+-- espcCCGroup .2.2.2.1.18
+-- esPointConfigHumidTable .2.2.3
+-- esPointConfigHumidEntry .2.2.3.1
+-- espcHumidIndexES .2.2.3.1.1
+-- espcHumidIndexPoint .2.2.3.1.2
+-- espcHumidEnable .2.2.3.1.3
+-- espcHumidDeadband .2.2.3.1.4
+-- espcHumidVHighHumid .2.2.3.1.5
+-- espcHumidVHighActions .2.2.3.1.6
+-- espcHumidVHighTrapnum .2.2.3.1.7
+-- espcHumidVHighClass .2.2.3.1.8
+-- espcHumidHighHumid .2.2.3.1.9
+-- espcHumidHighActions .2.2.3.1.10
+-- espcHumidHighTrapnum .2.2.3.1.11
+-- espcHumidHighClass .2.2.3.1.12
+-- espcHumidNormalActions .2.2.3.1.13
+-- espcHumidNormalTrapnum .2.2.3.1.14
+-- espcHumidNormalClass .2.2.3.1.15
+-- espcHumidLowHumid .2.2.3.1.16
+-- espcHumidLowActions .2.2.3.1.17
+-- espcHumidLowTrapnum .2.2.3.1.18
+-- espcHumidLowClass .2.2.3.1.19
+-- espcHumidVLowHumid .2.2.3.1.20
+-- espcHumidVLowActions .2.2.3.1.21
+-- espcHumidVLowTrapnum .2.2.3.1.22
+-- espcHumidVLowClass .2.2.3.1.23
+-- espcHumidGroup .2.2.3.1.24
+-- esPointConfigAITable .2.2.5
+-- esPointConfigAIEntry .2.2.5.1
+-- espcAIIndexES .2.2.5.1.1
+-- espcAIIndexPoint .2.2.5.1.2
+-- espcAIEnable .2.2.5.1.3
+-- espcAIDeadband .2.2.5.1.5
+-- espcAIVhighValue .2.2.5.1.6
+-- espcAIVhighActions .2.2.5.1.7
+-- espcAIVhighTrapnum .2.2.5.1.8
+-- espcAIVhighClass .2.2.5.1.9
+-- espcAIHighValue .2.2.5.1.10
+-- espcAIHighActions .2.2.5.1.11
+-- espcAIHighTrapnum .2.2.5.1.12
+-- espcAIHighClass .2.2.5.1.13
+-- espcAINormalActions .2.2.5.1.14
+-- espcAINormalTrapnum .2.2.5.1.15
+-- espcAINormalClass .2.2.5.1.16
+-- espcAILowValue .2.2.5.1.17
+-- espcAILowActions .2.2.5.1.18
+-- espcAILowTrapnum .2.2.5.1.19
+-- espcAILowClass .2.2.5.1.20
+-- espcAIVlowValue .2.2.5.1.21
+-- espcAIVlowActions .2.2.5.1.22
+-- espcAIVlowTrapnum .2.2.5.1.23
+-- espcAIVlowClass .2.2.5.1.24
+-- espcAIConvUnitName .2.2.5.1.25
+-- espcAIConvHighValue .2.2.5.1.26
+-- espcAIConvHighUnit .2.2.5.1.27
+-- espcAIConvLowValue .2.2.5.1.29
+-- espcAIConvLowUnit .2.2.5.1.30
+-- espcAIDisplayFormat .2.2.5.1.32
+-- espcAIGroup .2.2.5.1.33
+-- esPointConfigOutputTable .2.2.6
+-- esPointConfigOutputEntry .2.2.6.1
+-- espcOutputIndexES .2.2.6.1.1
+-- espcOutputIndexPoint .2.2.6.1.2
+-- espcOutputEnable .2.2.6.1.3
+-- espcOutputActiveState .2.2.6.1.4
+-- espcOutputType .2.2.6.1.5
+-- espcOutputAliasValue .2.2.6.1.6
+-- espcOutputAliasColor .2.2.6.1.7
+-- espcOutputActiveAlias .2.2.6.1.10
+-- espcOutputActiveColor .2.2.6.1.11
+-- espcOutputActiveActions .2.2.6.1.12
+-- espcOutputActiveTrapnum .2.2.6.1.13
+-- espcOutputActiveClass .2.2.6.1.14
+-- espcOutputInactiveAlias .2.2.6.1.20
+-- espcOutputInactiveColor .2.2.6.1.21
+-- espcOutputInactiveActions .2.2.6.1.22
+-- espcOutputInactiveTrapnum .2.2.6.1.23
+-- espcOutputInactiveClass .2.2.6.1.24
+-- espcOutputGroup .2.2.6.1.25
+-- serialPorts .2.3
+-- numberPorts .2.3.1
+-- portConfigTable .2.3.2
+-- portConfigEntry .2.3.2.1
+-- portConfigIndex .2.3.2.1.1
+-- portConfigBaud .2.3.2.1.2
+-- portConfigDataFormat .2.3.2.1.3
+-- portConfigStripPtOutputLfs .2.3.2.1.4
+-- portConfigStripPtInputLfs .2.3.2.1.5
+-- portConfigMaskEnable .2.3.2.1.7
+-- portConfigDAEnable .2.3.2.1.8
+-- portConfigStoreAlarmsDPT .2.3.2.1.9
+-- portConfigRecordTimeout .2.3.2.1.10
+-- portConfigDataType .2.3.2.1.11
+-- portConfigEtxToCRLF .2.3.2.1.12
+-- portConfigMLREnable .2.3.2.1.13
+-- portConfigMLRStartField1Pos .2.3.2.1.14
+-- portConfigMLRStartField1Text .2.3.2.1.15
+-- portConfigMLRStartField2Pos .2.3.2.1.16
+-- portConfigMLRStartField2Text .2.3.2.1.17
+-- portConfigMLRNumLinesBefore .2.3.2.1.18
+-- portConfigMLREndDetection .2.3.2.1.19
+-- portConfigMLRLineCount .2.3.2.1.20
+-- portConfigMLREndField1Pos .2.3.2.1.21
+-- portConfigMLREndField1Text .2.3.2.1.22
+-- portConfigMLREndField2Pos .2.3.2.1.23
+-- portConfigMLREndField2Text .2.3.2.1.24
+-- portConfigMLRUseComplexRules .2.3.2.1.25
+-- portConfigBufferPT .2.3.2.1.26
+-- portConfigId .2.3.2.1.27
+-- portConfigMode .2.3.2.1.28
+-- portConfigHsk .2.3.2.1.29
+-- network .2.4
+-- interface .2.4.1
+-- ethernet .2.4.1.1
+-- ethernet1 .2.4.1.1.1
+-- eth1Mode .2.4.1.1.1.1
+-- eth1Address .2.4.1.1.1.2
+-- eth1SubnetMask .2.4.1.1.1.3
+-- eth1Router .2.4.1.1.1.4
+-- eth1VLAN .2.4.1.1.1.5
+-- eth1VLAN1 .2.4.1.1.1.5.1
+-- eth1VLAN1ID .2.4.1.1.1.5.1.1
+-- eth1VLAN1Priority .2.4.1.1.1.5.1.2
+-- eth1VLAN1Address .2.4.1.1.1.5.1.3
+-- eth1VLAN1SubnetMask .2.4.1.1.1.5.1.4
+-- eth1VLAN1Router .2.4.1.1.1.5.1.5
+-- eth1VLAN2 .2.4.1.1.1.5.2
+-- eth1VLAN2ID .2.4.1.1.1.5.2.1
+-- eth1VLAN2Priority .2.4.1.1.1.5.2.2
+-- eth1VLAN2Address .2.4.1.1.1.5.2.3
+-- eth1VLAN2SubnetMask .2.4.1.1.1.5.2.4
+-- eth1VLAN2Router .2.4.1.1.1.5.2.5
+-- eth1VLAN3 .2.4.1.1.1.5.3
+-- eth1VLAN3ID .2.4.1.1.1.5.3.1
+-- eth1VLAN3Priority .2.4.1.1.1.5.3.2
+-- eth1VLAN3Address .2.4.1.1.1.5.3.3
+-- eth1VLAN3SubnetMask .2.4.1.1.1.5.3.4
+-- eth1VLAN3Router .2.4.1.1.1.5.3.5
+-- eth1VLAN4 .2.4.1.1.1.5.4
+-- eth1VLAN4ID .2.4.1.1.1.5.4.1
+-- eth1VLAN4Priority .2.4.1.1.1.5.4.2
+-- eth1VLAN4Address .2.4.1.1.1.5.4.3
+-- eth1VLAN4SubnetMask .2.4.1.1.1.5.4.4
+-- eth1VLAN4Router .2.4.1.1.1.5.4.5
+-- eth1VLAN5 .2.4.1.1.1.5.5
+-- eth1VLAN5ID .2.4.1.1.1.5.5.1
+-- eth1VLAN5Priority .2.4.1.1.1.5.5.2
+-- eth1VLAN5Address .2.4.1.1.1.5.5.3
+-- eth1VLAN5SubnetMask .2.4.1.1.1.5.5.4
+-- eth1VLAN5Router .2.4.1.1.1.5.5.5
+-- eth1VLAN6 .2.4.1.1.1.5.6
+-- eth1VLAN6ID .2.4.1.1.1.5.6.1
+-- eth1VLAN6Priority .2.4.1.1.1.5.6.2
+-- eth1VLAN6Address .2.4.1.1.1.5.6.3
+-- eth1VLAN6SubnetMask .2.4.1.1.1.5.6.4
+-- eth1VLAN6Router .2.4.1.1.1.5.6.5
+-- eth1MAC .2.4.1.1.1.6
+-- eth1IPv6 .2.4.1.1.1.7
+-- eth1IPv6Mode .2.4.1.1.1.7.1
+-- eth1IPv6Static .2.4.1.1.1.7.2
+-- eth1IPv6StaticAddress .2.4.1.1.1.7.2.1
+-- eth1IPv6StaticRouter .2.4.1.1.1.7.2.2
+-- eth1IPv6Auto .2.4.1.1.1.7.3
+-- eth1IPv6AutoAddress1 .2.4.1.1.1.7.3.1
+-- eth1IPv6AutoAddress2 .2.4.1.1.1.7.3.2
+-- eth1IPv6AutoAddress3 .2.4.1.1.1.7.3.3
+-- eth1IPv6AutoAddress4 .2.4.1.1.1.7.3.4
+-- eth1IPv6LinkLocalAddress .2.4.1.1.1.7.4
+-- ethernet2 .2.4.1.1.2
+-- eth2Mode .2.4.1.1.2.1
+-- eth2Address .2.4.1.1.2.2
+-- eth2SubnetMask .2.4.1.1.2.3
+-- eth2Router .2.4.1.1.2.4
+-- eth2VLAN .2.4.1.1.2.5
+-- eth2VLAN1 .2.4.1.1.2.5.1
+-- eth2VLAN1ID .2.4.1.1.2.5.1.1
+-- eth2VLAN1Priority .2.4.1.1.2.5.1.2
+-- eth2VLAN1Address .2.4.1.1.2.5.1.3
+-- eth2VLAN1SubnetMask .2.4.1.1.2.5.1.4
+-- eth2VLAN1Router .2.4.1.1.2.5.1.5
+-- eth2VLAN2 .2.4.1.1.2.5.2
+-- eth2VLAN2ID .2.4.1.1.2.5.2.1
+-- eth2VLAN2Priority .2.4.1.1.2.5.2.2
+-- eth2VLAN2Address .2.4.1.1.2.5.2.3
+-- eth2VLAN2SubnetMask .2.4.1.1.2.5.2.4
+-- eth2VLAN2Router .2.4.1.1.2.5.2.5
+-- eth2VLAN3 .2.4.1.1.2.5.3
+-- eth2VLAN3ID .2.4.1.1.2.5.3.1
+-- eth2VLAN3Priority .2.4.1.1.2.5.3.2
+-- eth2VLAN3Address .2.4.1.1.2.5.3.3
+-- eth2VLAN3SubnetMask .2.4.1.1.2.5.3.4
+-- eth2VLAN3Router .2.4.1.1.2.5.3.5
+-- eth2VLAN4 .2.4.1.1.2.5.4
+-- eth2VLAN4ID .2.4.1.1.2.5.4.1
+-- eth2VLAN4Priority .2.4.1.1.2.5.4.2
+-- eth2VLAN4Address .2.4.1.1.2.5.4.3
+-- eth2VLAN4SubnetMask .2.4.1.1.2.5.4.4
+-- eth2VLAN4Router .2.4.1.1.2.5.4.5
+-- eth2VLAN5 .2.4.1.1.2.5.5
+-- eth2VLAN5ID .2.4.1.1.2.5.5.1
+-- eth2VLAN5Priority .2.4.1.1.2.5.5.2
+-- eth2VLAN5Address .2.4.1.1.2.5.5.3
+-- eth2VLAN5SubnetMask .2.4.1.1.2.5.5.4
+-- eth2VLAN5Router .2.4.1.1.2.5.5.5
+-- eth2VLAN6 .2.4.1.1.2.5.6
+-- eth2VLAN6ID .2.4.1.1.2.5.6.1
+-- eth2VLAN6Priority .2.4.1.1.2.5.6.2
+-- eth2VLAN6Address .2.4.1.1.2.5.6.3
+-- eth2VLAN6SubnetMask .2.4.1.1.2.5.6.4
+-- eth2VLAN6Router .2.4.1.1.2.5.6.5
+-- eth2MAC .2.4.1.1.2.6
+-- eth2IPv6 .2.4.1.1.2.7
+-- eth2IPv6Mode .2.4.1.1.2.7.1
+-- eth2IPv6Static .2.4.1.1.2.7.2
+-- eth2IPv6StaticAddress .2.4.1.1.2.7.2.1
+-- eth2IPv6StaticRouter .2.4.1.1.2.7.2.2
+-- eth2IPv6Auto .2.4.1.1.2.7.3
+-- eth2IPv6AutoAddress1 .2.4.1.1.2.7.3.1
+-- eth2IPv6AutoAddress2 .2.4.1.1.2.7.3.2
+-- eth2IPv6AutoAddress3 .2.4.1.1.2.7.3.3
+-- eth2IPv6AutoAddress4 .2.4.1.1.2.7.3.4
+-- eth2IPv6LinkLocalAddress .2.4.1.1.2.7.4
+-- defaultRouter .2.4.2
+-- dnsTable .2.4.3
+-- dnsEntry .2.4.3.1
+-- dnsIndex .2.4.3.1.1
+-- dnsAddress .2.4.3.1.2
+-- hostname .2.4.4
+-- hostTable .2.4.5
+-- hostEntry .2.4.5.1
+-- hostIndex .2.4.5.1.1
+-- hostDeclaration .2.4.5.1.2
+-- ncpDuplex .2.4.6
+-- ncpTimeout .2.4.7
+-- snmp .2.4.8
+-- snmpAgentEnable .2.4.8.1
+-- snmpNotificationCaptureEnable .2.4.8.5
+-- snmpNotificationCaptureFile .2.4.8.6
+-- snmpNotificationTx .2.4.8.7
+-- snmpNtfnAttempts .2.4.8.7.1
+-- snmpNtfnTimeout .2.4.8.7.2
+-- snmpNtfnCycles .2.4.8.7.3
+-- snmpNtfnSnooze .2.4.8.7.4
+-- snmpProxy .2.4.8.8
+-- snmpProxyTable .2.4.8.8.1
+-- snmpProxyEntry .2.4.8.8.1.1
+-- snmpProxyIndex .2.4.8.8.1.1.1
+-- snmpProxyEgressOIDBranch .2.4.8.8.1.1.2
+-- snmpProxyIP .2.4.8.8.1.1.3
+-- snmpProxyPort .2.4.8.8.1.1.4
+-- snmpProxyIngressOIDBranch .2.4.8.8.1.1.5
+-- snmpProxyName .2.4.8.8.1.1.6
+-- snmpPoll .2.4.8.9
+-- snmpPMode .2.4.8.9.1
+-- snmpPBufferFile .2.4.8.9.2
+-- snmpPBufferAllPeriod .2.4.8.9.3
+-- snmpPRequestTable .2.4.8.9.4
+-- snmpPRequestEntry .2.4.8.9.4.1
+-- snmpPRequestIndex .2.4.8.9.4.1.1
+-- snmpPRequestDescription .2.4.8.9.4.1.2
+-- snmpPRequestAgent .2.4.8.9.4.1.3
+-- snmpPRequestReadcom .2.4.8.9.4.1.4
+-- snmpPRequestOID .2.4.8.9.4.1.5
+-- snmpPRequestPeriod .2.4.8.9.4.1.6
+-- snmpPRequestID .2.4.8.9.4.1.7
+-- snmpPRequestThreshold .2.4.8.9.4.1.8
+-- snmpPRequestResultStatus .2.4.8.9.4.1.10
+-- snmpPRequestResultValue .2.4.8.9.4.1.11
+-- snmpPRequestResultTime .2.4.8.9.4.1.12
+-- snmpPRequestResultType .2.4.8.9.4.1.13
+-- ftpPush .2.4.9
+-- ftpPushEnable .2.4.9.1
+-- ftpPushServer .2.4.9.2
+-- ftpPushAccount .2.4.9.5
+-- ftpPushDirectory .2.4.9.6
+-- ftpPushperiod .2.4.9.7
+-- ftpPushPushFileTable .2.4.9.8
+-- ftpPushPushFileEntry .2.4.9.8.1
+-- ftpPushPushFileIndex .2.4.9.8.1.1
+-- ftpPushPushFile .2.4.9.8.1.2
+-- ftpPushPushAudit .2.4.9.9
+-- ftpPushPushAlarms .2.4.9.10
+-- ftpPushRemoteFileTable .2.4.9.11
+-- ftpPushRemoteFileEntry .2.4.9.11.1
+-- ftpPushRemoteFileIndex .2.4.9.11.1.1
+-- ftpPushRemoteFileName .2.4.9.11.1.2
+-- ftpPushRemoteAlarmName .2.4.9.12
+-- ftpPushPassive .2.4.9.13
+-- ftpPushIncludeDate .2.4.9.14
+-- ftpPushIncludeTime .2.4.9.15
+-- ftpPushIncludeSeq .2.4.9.16
+-- ftpPushPermissions .2.4.9.17
+-- ppp .2.4.10
+-- pppDial .2.4.10.1
+-- pppDialEnable .2.4.10.1.1
+-- pppDialNumber .2.4.10.1.2
+-- pppDialIdleTimeout .2.4.10.1.5
+-- pppDialRetries .2.4.10.1.6
+-- pppDialCDTimeout .2.4.10.1.7
+-- pppDialLoginTimeout .2.4.10.1.8
+-- pppDialMdmInit .2.4.10.1.9
+-- pppDialSuggestIP .2.4.10.1.10
+-- pppDialPlainLogin .2.4.10.1.11
+-- pppHost .2.4.10.2
+-- pppHostEnable .2.4.10.2.1
+-- pppHostIdleTimeout .2.4.10.2.2
+-- pppHostLocalIP .2.4.10.2.3
+-- pppHostRemoteIP .2.4.10.2.4
+-- routing .2.4.11
+-- pppRoutingEnable .2.4.11.1
+-- ethRoutingEnable .2.4.11.2
+-- ethRoutingNATEnable .2.4.11.3
+-- routingInterface .2.4.11.4
+-- eth2WanRoutingEnable .2.4.11.5
+-- netSecurity .2.4.12
+-- ipRestriction .2.4.12.1
+-- ipRestrictionTable .2.4.12.1.1
+-- ipRestrictionEntry .2.4.12.1.1.1
+-- ipRestrictionIndex .2.4.12.1.1.1.1
+-- ipRestrictionEnable .2.4.12.1.1.1.2
+-- ipRestrictionMask .2.4.12.1.1.1.3
+-- rts .2.4.13
+-- rtsFileTable .2.4.13.1
+-- rtsFileEntry .2.4.13.1.1
+-- rtsFileIndex .2.4.13.1.1.1
+-- rtsFileMode .2.4.13.1.1.2
+-- rtsFileShowAnswer .2.4.13.1.1.3
+-- rtsFileReqXON .2.4.13.1.1.4
+-- rtsFileTimeout .2.4.13.1.1.5
+-- rtsFileEmptyClose .2.4.13.1.1.6
+-- rtsFilePushHost .2.4.13.1.1.7
+-- rtsFilePushPort .2.4.13.1.1.8
+-- rtsFilePushRetryTimer .2.4.13.1.1.9
+-- rtsAlarms .2.4.13.2
+-- rtsAlarmsMode .2.4.13.2.1
+-- rtsAlarmsShowAnswer .2.4.13.2.2
+-- rtsAlarmsReqXON .2.4.13.2.3
+-- rtsAlarmsTimeout .2.4.13.2.4
+-- rtsAlarmsEmptyClose .2.4.13.2.5
+-- rtsAlarmsPushHost .2.4.13.2.6
+-- rtsAlarmsPushPort .2.4.13.2.7
+-- rtsAlarmsPushRetryTimer .2.4.13.2.8
+-- trap .2.4.14
+-- trapInclude .2.4.14.1
+-- trapIncludeDateTime .2.4.14.1.1
+-- trapIncludeSiteName .2.4.14.1.2
+-- trapIncludeSensorID .2.4.14.1.3
+-- trapIncludeUDName .2.4.14.1.4
+-- trapIncludeUDState .2.4.14.1.5
+-- trapIncludeSourceAddress .2.4.14.1.6
+-- trapAuthFailEnable .2.4.14.2
+-- routeTest .2.4.15
+-- routeTestEnable .2.4.15.1
+-- routeTestPeriod .2.4.15.2
+-- routeTestAddressTable .2.4.15.3
+-- routeTestAddressEntry .2.4.15.3.1
+-- routeTestAddressIndex .2.4.15.3.1.1
+-- routeTestAddress .2.4.15.3.1.2
+-- wireless .2.4.16
+-- wirelessMode .2.4.16.1
+-- wirelessAPN .2.4.16.2
+-- wirelessIdleTimeout .2.4.16.3
+-- wirelessDRE .2.4.16.9
+-- wirelessPPPUsername .2.4.16.10
+-- wirelessFirewall .2.4.16.11
+-- wirelessKeepaliveThreshold .2.4.16.12
+-- wirelessPPPDebug .2.4.16.13
+-- wirelessConnectivity .2.4.16.20
+-- wirelessConnEnable .2.4.16.20.1
+-- wirelessConnCheckInterval .2.4.16.20.2
+-- wirelessConnFailThreshold .2.4.16.20.3
+-- wirelessConnIP1 .2.4.16.20.10
+-- wirelessConnIP2 .2.4.16.20.11
+-- email .2.4.17
+-- emailServer .2.4.17.1
+-- emailDomain .2.4.17.2
+-- emailAuthEnable .2.4.17.3
+-- netAdvanced .2.4.18
+-- arpFilter .2.4.18.1
+-- web .2.4.19
+-- webEnable .2.4.19.1
+-- webPort .2.4.19.2
+-- webTimeout .2.4.19.3
+-- webXMLProxy .2.4.19.4
+-- wxpEnable .2.4.19.4.1
+-- wxpDeviceTable .2.4.19.4.2
+-- wxpDeviceEntry .2.4.19.4.2.1
+-- wxpDeviceIndex .2.4.19.4.2.1.1
+-- wxpDeviceEnable .2.4.19.4.2.1.2
+-- wxpDeviceIPAddress .2.4.19.4.2.1.3
+-- wxpDevicePort .2.4.19.4.2.1.4
+-- wxpDeviceRemoteFile .2.4.19.4.2.1.5
+-- wxpDeviceLocalFile .2.4.19.4.2.1.6
+-- wxpDeviceTimeout .2.4.19.4.2.1.7
+-- wxpDeviceTimestamp .2.4.19.4.2.1.8
+-- ethExpan .2.4.20
+-- ethExpanIp .2.4.20.1
+-- ethExpanMask .2.4.20.2
+-- ethExpanCardTable .2.4.20.3
+-- ethExpanCardEntry .2.4.20.3.1
+-- ethExpanCardIndex .2.4.20.3.1.1
+-- ethExpanCardMAC .2.4.20.3.1.2
+-- ethExpanDHCP .2.4.20.6
+-- ethExpanDHCPStartIp .2.4.20.6.1
+-- ethExpanDHCPLeaseTime .2.4.20.6.2
+-- ipv6 .2.4.21
+-- ipv6DefaultRouter .2.4.21.1
+-- cpe .2.4.22
+-- cpeTable .2.4.22.1
+-- cpeEntry .2.4.22.1.1
+-- cpeIndex .2.4.22.1.1.1
+-- cpeHost .2.4.22.1.1.2
+-- cpeName .2.4.22.1.1.3
+-- cpeDescription .2.4.22.1.1.4
+-- cpeKeepalive .2.4.22.1.1.5
+-- cpeThreshold .2.4.22.1.1.6
+-- cpeEventReminderInterval .2.4.22.1.1.7
+-- cpeKeepaliveTicks .2.4.22.1.1.20
+-- cpePingSize .2.4.22.1.1.21
+-- cpeInfoReset .2.4.22.1.1.30
+-- cpeInfoNumReq .2.4.22.1.1.31
+-- cpeInfoNumGoodResp .2.4.22.1.1.32
+-- cpeInfoNumBadResp .2.4.22.1.1.33
+-- cpeInfoNumLostResp .2.4.22.1.1.34
+-- cpeInfoPercentLoss .2.4.22.1.1.35
+-- cpeInfoPercentBad .2.4.22.1.1.36
+-- dnp3 .2.4.23
+-- dnp3General .2.4.23.1
+-- dnp3Mode .2.4.23.1.1
+-- dnp3SelfAddressEnable .2.4.23.1.2
+-- dnp3KeepaliveTimeout .2.4.23.1.3
+-- dnp3MaxRXFragmentSize .2.4.23.1.4
+-- dnp3MaxTXFragmentSize .2.4.23.1.5
+-- dnp3UnsolResponseEnable .2.4.23.1.6
+-- dnp3UnsolResponseTimeout .2.4.23.1.7
+-- dnp3UnsolResponseRetries .2.4.23.1.8
+-- dnp3LogFilter .2.4.23.1.9
+-- dnp3Outstation .2.4.23.2
+-- dnp3OutstationTCPPort .2.4.23.2.1
+-- dnp3OutstationDNP3Address .2.4.23.2.2
+-- dnp3OutstationMasterIPAddress .2.4.23.2.3
+-- dnp3OutstationMasterDNP3Address .2.4.23.2.4
+-- dnp3OutstationUnsolResponseDNP3Address .2.4.23.2.5
+-- dnp3Master .2.4.23.3
+-- dnp3Error .2.4.23.4
+-- dnp3DuplicateFragmentCount .2.4.23.4.1
+-- dnp3CollidingFragmentCount .2.4.23.4.2
+-- dnp3UnsolResponseCfmFailCount .2.4.23.4.3
+-- dnp3SolCfmFailCount .2.4.23.4.4
+-- dnp3ObjParseErrorCount .2.4.23.4.5
+-- dnp3FrameParseErrorCount .2.4.23.4.6
+-- dnp3DiscardedFrameCount .2.4.23.4.7
+-- dnp3BadBlockCount .2.4.23.4.8
+-- dnp3UnsolResponseRetryCount .2.4.23.4.9
+-- dnp3UnsupportedFrameCount .2.4.23.4.10
+-- dnp3Status .2.4.23.5
+-- dnp3OutstationCount .2.4.23.5.1
+-- dnp3ConnPeer .2.4.23.5.2
+-- dnp3StartTime .2.4.23.5.3
+-- dnp3EventAwaitingSolCfmCount .2.4.23.5.4
+-- dnp3EventAwaitingUnsolCfmCount .2.4.23.5.5
+-- dnp3EventCount .2.4.23.5.6
+-- dnp3EventClass1Count .2.4.23.5.7
+-- dnp3EventClass2Count .2.4.23.5.8
+-- dnp3EventClass3Count .2.4.23.5.9
+-- dnp3RxFragmentTime .2.4.23.5.10
+-- dnp3TxFragmentTime .2.4.23.5.11
+-- dnp3TxCachedResponseCount .2.4.23.5.12
+-- dnp3TxUnsolResponseCount .2.4.23.5.13
+-- dnp3TxSolResponseCount .2.4.23.5.14
+-- dnp3TxFragmentReqCfmCount .2.4.23.5.15
+-- dnp3RxUnsolResponseCfmCount .2.4.23.5.16
+-- dnp3RxSolResponseCfmCount .2.4.23.5.17
+-- dnp3RxFunctionCount .2.4.23.5.18
+-- dnp3RxReadFunctionCount .2.4.23.5.19
+-- dnp3RxWriteFunctionCount .2.4.23.5.20
+-- dnp3RxDirOpFunctionCount .2.4.23.5.21
+-- dnp3RxEnableURCount .2.4.23.5.22
+-- dnp3RxDisableURCount .2.4.23.5.23
+-- dnp3RxSolObjectCount .2.4.23.5.40
+-- dnp3TxSolObjectCount .2.4.23.5.41
+-- dnp3RxFrameTime .2.4.23.5.42
+-- dnp3TxFrameTime .2.4.23.5.43
+-- dnp3TxFrameCount .2.4.23.5.44
+-- dnp3RxAcceptedFrameCount .2.4.23.5.45
+-- dnp3RxSupportedFrameCount .2.4.23.5.46
+-- modem .2.5
+-- modemFormat .2.5.1
+-- modemInitString .2.5.2
+-- modemCallAttempts .2.5.4
+-- modemCallDelay .2.5.5
+-- modemCmdTimout .2.5.6
+-- modemGoto .2.5.7
+-- modemClid .2.5.8
+-- modemCLIDEnable .2.5.8.1
+-- modemCLIDNumberTable .2.5.8.2
+-- modemCLIDNumberEntry .2.5.8.2.1
+-- modemCLIDNumberIndex .2.5.8.2.1.1
+-- modemCLIDNumber .2.5.8.2.1.2
+-- modemTAPInitString .2.5.9
+-- modemTAP8N1 .2.5.10
+-- time .2.8
+-- clock .2.8.1
+-- console .2.10
+-- consoleDuplex .2.10.1
+-- consoleTimeout .2.10.2
+-- consoleConfirm .2.10.7
+-- unitSecurity .2.11
+-- secCore .2.11.1
+-- scShowPasswordPrompt .2.11.1.1
+-- scConsoleLoginRequired .2.11.1.2
+-- scModemLoginRequired .2.11.1.3
+-- scTelnetLoginRequired .2.11.1.4
+-- scTelnetPTLoginRequired .2.11.1.5
+-- scRTSLoginRequired .2.11.1.6
+-- scAuthMode .2.11.1.7
+-- scRightsGroup .2.11.1.8
+-- secUserTable .2.11.2
+-- secUserEntry .2.11.2.1
+-- secUserIndex .2.11.2.1.1
+-- secUserEnable .2.11.2.1.2
+-- secUserConnectVia .2.11.2.1.5
+-- secUserLoginTo .2.11.2.1.6
+-- secUserAccessFile .2.11.2.1.7
+-- secUserPTEscapeTo .2.11.2.1.9
+-- secUserPPPType .2.11.2.1.10
+-- secUserRights .2.11.2.1.11
+-- secUserEventsReadAccess .2.11.2.1.13
+-- secUserAuditReadAccess .2.11.2.1.14
+-- secUserEventsWriteAccess .2.11.2.1.16
+-- secUserAuditWriteAccess .2.11.2.1.17
+-- secUserExpiration .2.11.2.1.18
+-- secUserCallbackNumber1 .2.11.2.1.19
+-- secUserCallbackNumber2 .2.11.2.1.20
+-- secUserCallbackNumber3 .2.11.2.1.21
+-- secUserChallengeTelnetMode .2.11.2.1.22
+-- secUserChallengeModemMode .2.11.2.1.23
+-- secUserChallengeConsoleMode .2.11.2.1.24
+-- secUserChallengeTelnetSendTo .2.11.2.1.25
+-- secUserChallengeModemSendTo .2.11.2.1.26
+-- secUserChallengeExpiration .2.11.2.1.27
+-- secFactory .2.11.3
+-- sfEnable .2.11.3.1
+-- sfSecret .2.11.3.2
+-- secSSH .2.11.4
+-- secVPN .2.11.5
+-- event .2.12
+-- evCore .2.12.1
+-- evClassNameTable .2.12.1.1
+-- evClassNameEntry .2.12.1.1.1
+-- evClassNameIndex .2.12.1.1.1.1
+-- evClassName .2.12.1.1.1.2
+-- evReminderInterval .2.12.1.2
+-- evLog .2.12.1.3
+-- evLogEnable .2.12.1.3.1
+-- evLogStoreAlarm .2.12.1.3.2
+-- evLogMaxSize .2.12.1.3.3
+-- evLogStoreSensor .2.12.1.3.4
+-- evLogTimeStampAlarms .2.12.1.3.5
+-- evLogPrependName .2.12.1.3.6
+-- evMgmt .2.12.1.4
+-- evMgmtReprocess .2.12.1.4.3
+-- evData .2.12.2
+-- evdCore .2.12.2.1
+-- evdExitOnTrue .2.12.2.1.1
+-- evdFilterAction .2.12.2.1.2
+-- evdWildCardChar .2.12.2.1.3
+-- evdTable .2.12.2.2
+-- evdEntry .2.12.2.2.1
+-- evdIndex .2.12.2.2.1.1
+-- evdEnable .2.12.2.2.1.2
+-- evdName .2.12.2.2.1.3
+-- evdEquation .2.12.2.2.1.4
+-- evdThreshold .2.12.2.2.1.5
+-- evdAutoclear .2.12.2.2.1.6
+-- evdClearInterval .2.12.2.2.1.7
+-- evdClearTime .2.12.2.2.1.8
+-- evdActions .2.12.2.2.1.9
+-- evdClass .2.12.2.2.1.10
+-- evdTrapNum .2.12.2.2.1.11
+-- evdMode .2.12.2.2.1.12
+-- evdFieldTable .2.12.2.3
+-- evdFieldEntry .2.12.2.3.1
+-- evdFieldIndex .2.12.2.3.1.1
+-- evdFieldStart .2.12.2.3.1.2
+-- evdFieldLength .2.12.2.3.1.3
+-- evdFieldName .2.12.2.3.1.4
+-- evdFieldLine .2.12.2.3.1.5
+-- evdFieldType .2.12.2.3.1.6
+-- evdMacroTable .2.12.2.4
+-- evdMacroEntry .2.12.2.4.1
+-- evdMacroIndex .2.12.2.4.1.1
+-- evdMacroName .2.12.2.4.1.2
+-- evdMacroEquation .2.12.2.4.1.3
+-- evNoData1 .2.12.3
+-- evNoData1Enable .2.12.3.1
+-- evNoData1Actions .2.12.3.2
+-- evNoData1Message .2.12.3.3
+-- evNoData1TrapNum .2.12.3.4
+-- evNoData1Class .2.12.3.5
+-- evNoData1Sched1Begin .2.12.3.6
+-- evNoData1Sched1End .2.12.3.7
+-- evNoData1Sched1Duration .2.12.3.8
+-- evNoData1Sched2Begin .2.12.3.9
+-- evNoData1Sched2End .2.12.3.10
+-- evNoData1Sched2Duration .2.12.3.11
+-- evNoData1PortEnableTable .2.12.3.12
+-- evNoData1PortEnableEntry .2.12.3.12.1
+-- evNoData1PortEnableIndex .2.12.3.12.1.1
+-- evNoData1PortEnable .2.12.3.12.1.2
+-- evNoData1Exclusions .2.12.3.13
+-- evNoData1Days .2.12.3.14
+-- evNoData2 .2.12.4
+-- evNoData2Enable .2.12.4.1
+-- evNoData2Actions .2.12.4.2
+-- evNoData2Message .2.12.4.3
+-- evNoData2TrapNum .2.12.4.4
+-- evNoData2Class .2.12.4.5
+-- evNoData2Sched1Begin .2.12.4.6
+-- evNoData2Sched1End .2.12.4.7
+-- evNoData2Sched1Duration .2.12.4.8
+-- evNoData2Sched2Begin .2.12.4.9
+-- evNoData2Sched2End .2.12.4.10
+-- evNoData2Sched2Duration .2.12.4.11
+-- evNoData2PortEnableTable .2.12.4.12
+-- evNoData2PortEnableEntry .2.12.4.12.1
+-- evNoData2PortEnableIndex .2.12.4.12.1.1
+-- evNoData2PortEnable .2.12.4.12.1.2
+-- evNoData2Exclusions .2.12.4.13
+-- evNoData2Days .2.12.4.14
+-- evSched1 .2.12.5
+-- evSched1Enable .2.12.5.1
+-- evSched1Actions .2.12.5.2
+-- evSched1Message .2.12.5.3
+-- evSched1TrapNum .2.12.5.4
+-- evSched1Class .2.12.5.5
+-- evSched1Sunday .2.12.5.6
+-- evSched1Monday .2.12.5.7
+-- evSched1Tuesday .2.12.5.8
+-- evSched1Wednesday .2.12.5.9
+-- evSched1Thursday .2.12.5.10
+-- evSched1Friday .2.12.5.11
+-- evSched1Saturday .2.12.5.12
+-- evSched1Exclusions .2.12.5.13
+-- evSched2 .2.12.6
+-- evSched2Enable .2.12.6.1
+-- evSched2Actions .2.12.6.2
+-- evSched2Message .2.12.6.3
+-- evSched2TrapNum .2.12.6.4
+-- evSched2Class .2.12.6.5
+-- evSched2Sunday .2.12.6.6
+-- evSched2Monday .2.12.6.7
+-- evSched2Tuesday .2.12.6.8
+-- evSched2Wednesday .2.12.6.9
+-- evSched2Thursday .2.12.6.10
+-- evSched2Friday .2.12.6.11
+-- evSched2Saturday .2.12.6.12
+-- evSched2Exclusions .2.12.6.13
+-- evShskLowTable .2.12.7
+-- evShskLowEntry .2.12.7.1
+-- evShskLowIndex .2.12.7.1.1
+-- evShskLowEnable .2.12.7.1.2
+-- evShskLowActions .2.12.7.1.3
+-- evShskLowMessage .2.12.7.1.4
+-- evShskLowClass .2.12.7.1.5
+-- evShskLowTrapNum .2.12.7.1.6
+-- evShskHighTable .2.12.8
+-- evShskHighEntry .2.12.8.1
+-- evShskHighIndex .2.12.8.1.1
+-- evShskHighEnable .2.12.8.1.2
+-- evShskHighActions .2.12.8.1.3
+-- evShskHighMessage .2.12.8.1.4
+-- evShskHighClass .2.12.8.1.5
+-- evShskHighTrapNum .2.12.8.1.6
+-- evNoSensor .2.12.9
+-- evNoSensorTimeout .2.12.9.1
+-- evNoSensorActions .2.12.9.2
+-- evNoSensorTrapNum .2.12.9.3
+-- evNoSensorClass .2.12.9.4
+-- fuelSensor .2.12.11
+-- fuelSensorGeneralTable .2.12.11.1
+-- fsGenEntry .2.12.11.1.1
+-- fsGenIndex .2.12.11.1.1.1
+-- fsGenName .2.12.11.1.1.2
+-- fsGenSensorType .2.12.11.1.1.3
+-- fsGenDistanceUnit .2.12.11.1.1.4
+-- fsGenRawValueTop .2.12.11.1.1.5
+-- fsGenTopOffset .2.12.11.1.1.6
+-- fsGenRawValueBottom .2.12.11.1.1.7
+-- fsGenBottomOffset .2.12.11.1.1.8
+-- fsGenInputES .2.12.11.1.1.9
+-- fsGenInputPoint .2.12.11.1.1.10
+-- fsGenFilterAveraging .2.12.11.1.1.11
+-- fsGenSysrepEnable .2.12.11.1.1.12
+-- fsGenSysrepThreshold .2.12.11.1.1.13
+-- fsGenSysrepLimit .2.12.11.1.1.14
+-- fsGenSysrepPackage .2.12.11.1.1.15
+-- fsGenGroup .2.12.11.1.1.16
+-- fsGenEnable .2.12.11.1.1.17
+-- fsGenFuelType .2.12.11.1.1.18
+-- fuelSensorTankTable .2.12.11.2
+-- fsTankEntry .2.12.11.2.1
+-- fsTankIndex .2.12.11.2.1.1
+-- fsTankHeight .2.12.11.2.1.2
+-- fsTankDimA .2.12.11.2.1.3
+-- fsTankDimB .2.12.11.2.1.4
+-- fsTankVolume .2.12.11.2.1.5
+-- fsTankVolumeUnit .2.12.11.2.1.6
+-- fsTankShape .2.12.11.2.1.7
+-- fuelSensorCustomTankTable .2.12.11.3
+-- fsCustomTankEntry .2.12.11.3.1
+-- fsCustomTankIndexFS .2.12.11.3.1.1
+-- fsCustomTankIndexDatum .2.12.11.3.1.2
+-- fsCustomTankHeight .2.12.11.3.1.3
+-- fsCustomTankVolume .2.12.11.3.1.4
+-- fuelSensorVolumeTable .2.12.11.4
+-- fsVolumeEntry .2.12.11.4.1
+-- fsVolumeIndex .2.12.11.4.1.1
+-- fsVolumeEnable .2.12.11.4.1.2
+-- fsVolumeDeadband .2.12.11.4.1.3
+-- fsVolumeVHighValue .2.12.11.4.1.4
+-- fsVolumeVHighActions .2.12.11.4.1.5
+-- fsVolumeVHighTrapNum .2.12.11.4.1.6
+-- fsVolumeVHighClass .2.12.11.4.1.7
+-- fsVolumeHighValue .2.12.11.4.1.8
+-- fsVolumeHighActions .2.12.11.4.1.9
+-- fsVolumeHighTrapNum .2.12.11.4.1.10
+-- fsVolumeHighClass .2.12.11.4.1.11
+-- fsVolumeNormalActions .2.12.11.4.1.12
+-- fsVolumeNormalTrapNum .2.12.11.4.1.13
+-- fsVolumeNormalClass .2.12.11.4.1.14
+-- fsVolumeLowValue .2.12.11.4.1.15
+-- fsVolumeLowActions .2.12.11.4.1.16
+-- fsVolumeLowTrapNum .2.12.11.4.1.17
+-- fsVolumeLowClass .2.12.11.4.1.18
+-- fsVolumeVLowValue .2.12.11.4.1.19
+-- fsVolumeVLowActions .2.12.11.4.1.20
+-- fsVolumeVLowTrapNum .2.12.11.4.1.21
+-- fsVolumeVLowClass .2.12.11.4.1.22
+-- fuelSensorDisconnectTable .2.12.11.5
+-- fsDiscEntry .2.12.11.5.1
+-- fsDiscIndex .2.12.11.5.1.1
+-- fsDiscEnable .2.12.11.5.1.2
+-- fsDiscHighValue .2.12.11.5.1.3
+-- fsDiscLowValue .2.12.11.5.1.4
+-- fsDiscActions .2.12.11.5.1.5
+-- fsDiscTrapNum .2.12.11.5.1.6
+-- fsDiscClass .2.12.11.5.1.7
+-- fsDiscNormalActions .2.12.11.5.1.8
+-- fsDiscNormalTrapNum .2.12.11.5.1.9
+-- fsDiscNormalClass .2.12.11.5.1.10
+-- fuelSensorSuddenChangeTable .2.12.11.6
+-- fsSuddenChangeEntry .2.12.11.6.1
+-- fsSuddenChangeIndex .2.12.11.6.1.1
+-- fsSuddenChangeEnable .2.12.11.6.1.2
+-- fsSuddenChangeTime .2.12.11.6.1.3
+-- fsSuddenChangeAmplitude .2.12.11.6.1.4
+-- fsSuddenChangeActions .2.12.11.6.1.5
+-- fsSuddenChangeTrapNum .2.12.11.6.1.6
+-- fsSuddenChangeClass .2.12.11.6.1.7
+-- fuelSensorSlowChangeTable .2.12.11.7
+-- fuelSensorSlowChangeEntry .2.12.11.7.1
+-- fsSlowChangeIndex .2.12.11.7.1.1
+-- fsSlowChangeEnable .2.12.11.7.1.2
+-- fsSlowChangeTime .2.12.11.7.1.3
+-- fsSlowChangeAmplitude .2.12.11.7.1.4
+-- fsSlowChangeActions .2.12.11.7.1.5
+-- fsSlowChangeTrapNum .2.12.11.7.1.6
+-- fsSlowChangeClass .2.12.11.7.1.7
+-- acPowerMonitor .2.12.12
+-- acpmGeneralTable .2.12.12.1
+-- acpmGenEntry .2.12.12.1.1
+-- acpmGenIndex .2.12.12.1.1.1
+-- acpmGenDevice .2.12.12.1.1.2
+-- acpmGenName .2.12.12.1.1.3
+-- acpmGenAddress .2.12.12.1.1.4
+-- acpmGenPtRatio .2.12.12.1.1.5
+-- acpmGenCtRatio .2.12.12.1.1.6
+-- acpmGenPowerType .2.12.12.1.1.7
+-- acpmGenSysrepPackage .2.12.12.1.1.8
+-- acpmGenGroup .2.12.12.1.1.9
+-- acpmGenEnable .2.12.12.1.1.10
+-- acpmAvgVoltageTable .2.12.12.2
+-- acpmAvgVoltageEntry .2.12.12.2.1
+-- acpmAvgVoltageIndex .2.12.12.2.1.1
+-- acpmAvgVoltageEnable .2.12.12.2.1.2
+-- acpmAvgVoltageDeadband .2.12.12.2.1.3
+-- acpmAvgVoltageVHighValue .2.12.12.2.1.4
+-- acpmAvgVoltageVHighActions .2.12.12.2.1.5
+-- acpmAvgVoltageVHighTrapNum .2.12.12.2.1.6
+-- acpmAvgVoltageVHighClass .2.12.12.2.1.7
+-- acpmAvgVoltageHighValue .2.12.12.2.1.8
+-- acpmAvgVoltageHighActions .2.12.12.2.1.9
+-- acpmAvgVoltageHighTrapNum .2.12.12.2.1.10
+-- acpmAvgVoltageHighClass .2.12.12.2.1.11
+-- acpmAvgVoltageNormalActions .2.12.12.2.1.12
+-- acpmAvgVoltageNormalTrapNum .2.12.12.2.1.13
+-- acpmAvgVoltageNormalClass .2.12.12.2.1.14
+-- acpmAvgVoltageLowValue .2.12.12.2.1.15
+-- acpmAvgVoltageLowActions .2.12.12.2.1.16
+-- acpmAvgVoltageLowTrapNum .2.12.12.2.1.17
+-- acpmAvgVoltageLowClass .2.12.12.2.1.18
+-- acpmAvgVoltageVLowValue .2.12.12.2.1.19
+-- acpmAvgVoltageVLowActions .2.12.12.2.1.20
+-- acpmAvgVoltageVLowTrapNum .2.12.12.2.1.21
+-- acpmAvgVoltageVLowClass .2.12.12.2.1.22
+-- acpmAvgVoltageSysrepEnable .2.12.12.2.1.23
+-- acpmAvgVoltageSysrepThreshold .2.12.12.2.1.24
+-- acpmAvgVoltageSysrepLimit .2.12.12.2.1.25
+-- acpmAvgCurrentTable .2.12.12.3
+-- acpmAvgCurrentEntry .2.12.12.3.1
+-- acpmAvgCurrentIndex .2.12.12.3.1.1
+-- acpmAvgCurrentEnable .2.12.12.3.1.2
+-- acpmAvgCurrentDeadband .2.12.12.3.1.3
+-- acpmAvgCurrentVHighValue .2.12.12.3.1.4
+-- acpmAvgCurrentVHighActions .2.12.12.3.1.5
+-- acpmAvgCurrentVHighTrapNum .2.12.12.3.1.6
+-- acpmAvgCurrentVHighClass .2.12.12.3.1.7
+-- acpmAvgCurrentHighValue .2.12.12.3.1.8
+-- acpmAvgCurrentHighActions .2.12.12.3.1.9
+-- acpmAvgCurrentHighTrapNum .2.12.12.3.1.10
+-- acpmAvgCurrentHighClass .2.12.12.3.1.11
+-- acpmAvgCurrentNormalActions .2.12.12.3.1.12
+-- acpmAvgCurrentNormalTrapNum .2.12.12.3.1.13
+-- acpmAvgCurrentNormalClass .2.12.12.3.1.14
+-- acpmAvgCurrentLowValue .2.12.12.3.1.15
+-- acpmAvgCurrentLowActions .2.12.12.3.1.16
+-- acpmAvgCurrentLowTrapNum .2.12.12.3.1.17
+-- acpmAvgCurrentLowClass .2.12.12.3.1.18
+-- acpmAvgCurrentVLowValue .2.12.12.3.1.19
+-- acpmAvgCurrentVLowActions .2.12.12.3.1.20
+-- acpmAvgCurrentVLowTrapNum .2.12.12.3.1.21
+-- acpmAvgCurrentVLowClass .2.12.12.3.1.22
+-- acpmAvgCurrentSysrepEnable .2.12.12.3.1.23
+-- acpmAvgCurrentSysrepThreshold .2.12.12.3.1.24
+-- acpmAvgCurrentSysrepLimit .2.12.12.3.1.25
+-- acpmFreqTable .2.12.12.4
+-- acpmFreqEntry .2.12.12.4.1
+-- acpmFreqIndex .2.12.12.4.1.1
+-- acpmFreqEnable .2.12.12.4.1.2
+-- acpmFreqDeadband .2.12.12.4.1.3
+-- acpmFreqVHighValue .2.12.12.4.1.4
+-- acpmFreqVHighActions .2.12.12.4.1.5
+-- acpmFreqVHighTrapNum .2.12.12.4.1.6
+-- acpmFreqVHighClass .2.12.12.4.1.7
+-- acpmFreqHighValue .2.12.12.4.1.8
+-- acpmFreqHighActions .2.12.12.4.1.9
+-- acpmFreqHighTrapNum .2.12.12.4.1.10
+-- acpmFreqHighClass .2.12.12.4.1.11
+-- acpmFreqNormalActions .2.12.12.4.1.12
+-- acpmFreqNormalTrapNum .2.12.12.4.1.13
+-- acpmFreqNormalClass .2.12.12.4.1.14
+-- acpmFreqLowValue .2.12.12.4.1.15
+-- acpmFreqLowActions .2.12.12.4.1.16
+-- acpmFreqLowTrapNum .2.12.12.4.1.17
+-- acpmFreqLowClass .2.12.12.4.1.18
+-- acpmFreqVLowValue .2.12.12.4.1.19
+-- acpmFreqVLowActions .2.12.12.4.1.20
+-- acpmFreqVLowTrapNum .2.12.12.4.1.21
+-- acpmFreqVLowClass .2.12.12.4.1.22
+-- acpmFreqSysrepEnable .2.12.12.4.1.23
+-- acpmFreqSysrepThreshold .2.12.12.4.1.24
+-- acpmFreqSysrepLimit .2.12.12.4.1.25
+-- acpmTotalRealPowerTable .2.12.12.5
+-- acpmTRPEntry .2.12.12.5.1
+-- acpmTRPIndex .2.12.12.5.1.1
+-- acpmTRPEnable .2.12.12.5.1.2
+-- acpmTRPDeadband .2.12.12.5.1.3
+-- acpmTRPVHighValue .2.12.12.5.1.4
+-- acpmTRPVHighActions .2.12.12.5.1.5
+-- acpmTRPVHighTrapNum .2.12.12.5.1.6
+-- acpmTRPVHighClass .2.12.12.5.1.7
+-- acpmTRPHighValue .2.12.12.5.1.8
+-- acpmTRPHighActions .2.12.12.5.1.9
+-- acpmTRPHighTrapNum .2.12.12.5.1.10
+-- acpmTRPHighClass .2.12.12.5.1.11
+-- acpmTRPNormalActions .2.12.12.5.1.12
+-- acpmTRPNormalTrapNum .2.12.12.5.1.13
+-- acpmTRPNormalClass .2.12.12.5.1.14
+-- acpmTRPLowValue .2.12.12.5.1.15
+-- acpmTRPLowActions .2.12.12.5.1.16
+-- acpmTRPLowTrapNum .2.12.12.5.1.17
+-- acpmTRPLowClass .2.12.12.5.1.18
+-- acpmTRPVLowValue .2.12.12.5.1.19
+-- acpmTRPVLowActions .2.12.12.5.1.20
+-- acpmTRPVLowTrapNum .2.12.12.5.1.21
+-- acpmTRPVLowClass .2.12.12.5.1.22
+-- acpmTRPSysrepEnable .2.12.12.5.1.23
+-- acpmTRPSysrepThreshold .2.12.12.5.1.24
+-- acpmTRPSysrepLimit .2.12.12.5.1.25
+-- acpmDisconnectTable .2.12.12.6
+-- acpmDisconnectEntry .2.12.12.6.1
+-- acpmDisconnectIndex .2.12.12.6.1.1
+-- acpmDisconnectEnable .2.12.12.6.1.2
+-- acpmDisconnectActions .2.12.12.6.1.3
+-- acpmDisconnectTrapNum .2.12.12.6.1.4
+-- acpmDisconnectClass .2.12.12.6.1.5
+-- acpmDisconnectNormalActions .2.12.12.6.1.6
+-- acpmDisconnectNormalTrapNum .2.12.12.6.1.7
+-- acpmDisconnectNormalClass .2.12.12.6.1.8
+-- acpmTotalPowerFactorTable .2.12.12.7
+-- acpmTPFEntry .2.12.12.7.1
+-- acpmTPFIndex .2.12.12.7.1.1
+-- acpmTPFEnable .2.12.12.7.1.2
+-- acpmTPFDeadband .2.12.12.7.1.3
+-- acpmTPFNormalActions .2.12.12.7.1.4
+-- acpmTPFNormalTrapNum .2.12.12.7.1.5
+-- acpmTPFNormalClass .2.12.12.7.1.6
+-- acpmTPFLowValue .2.12.12.7.1.7
+-- acpmTPFLowActions .2.12.12.7.1.8
+-- acpmTPFLowTrapNum .2.12.12.7.1.9
+-- acpmTPFLowClass .2.12.12.7.1.10
+-- acpmTPFVLowValue .2.12.12.7.1.11
+-- acpmTPFVLowActions .2.12.12.7.1.12
+-- acpmTPFVLowTrapNum .2.12.12.7.1.13
+-- acpmTPFVLowClass .2.12.12.7.1.14
+-- acpmTPFSysrepEnable .2.12.12.7.1.15
+-- acpmTPFSysrepThreshold .2.12.12.7.1.16
+-- acpmTPFSysrepLimit .2.12.12.7.1.17
+-- evReset .2.12.16
+-- evResetEnable .2.12.16.1
+-- evResetDelay .2.12.16.2
+-- evResetActions .2.12.16.3
+-- evResetMessage .2.12.16.4
+-- evResetTrapnum .2.12.16.5
+-- evResetClass .2.12.16.6
+-- evGlobal .2.12.18
+-- evGlobalActions .2.12.18.1
+-- evGlobalTrapnum .2.12.18.2
+-- evHVAC .2.12.19
+-- evHVACGeneral .2.12.19.1
+-- evHVACBard .2.12.19.2
+-- evHVACBardLocal .2.12.19.2.1
+-- evHVACBardIPAddress .2.12.19.2.1.1
+-- evHVACBardPort .2.12.19.2.1.2
+-- evHVACBardTimeout .2.12.19.2.1.3
+-- evHVACBardXMLStatus .2.12.19.2.1.4
+-- evHVACBardXMLSettings .2.12.19.2.1.5
+-- evHVACBardWebSettingsHTML .2.12.19.2.1.6
+-- evHVACBardAlarm .2.12.19.2.1.7
+-- evHVACBardAlarmEnable .2.12.19.2.1.7.1
+-- evHVACBardAlarmActions .2.12.19.2.1.7.2
+-- evHVACBardAlarmTrapnum .2.12.19.2.1.7.3
+-- evHVACBardAlarmClass .2.12.19.2.1.7.4
+-- evHVACBardAlarmNormalActions .2.12.19.2.1.7.5
+-- evHVACBardAlarmNormalTrapnum .2.12.19.2.1.7.6
+-- evHVACBardAlarmNormalClass .2.12.19.2.1.7.7
+-- evHVACBardReset .2.12.19.2.1.8
+-- evHVACBardDefault .2.12.19.2.1.9
+-- evHVACBardSynchronized .2.12.19.2.2
+-- evHVACBardTempScale .2.12.19.2.2.1
+-- evHVACBardCoolThreshold .2.12.19.2.2.2
+-- evHVACBardCoolThresholdState .2.12.19.2.2.3
+-- evHVACBardHeatThreshold .2.12.19.2.2.4
+-- evHVACBardHeatDiff .2.12.19.2.2.5
+-- evHVACBardHeatDiffState .2.12.19.2.2.6
+-- evHVACBardBlower .2.12.19.2.2.7
+-- evHVACBardBlowerState .2.12.19.2.2.8
+-- evHVACBardAlternate .2.12.19.2.2.9
+-- evHVACBardAlternateState .2.12.19.2.2.10
+-- evHVACBardChangeover .2.12.19.2.2.11
+-- evHVACBardChangeoverState .2.12.19.2.2.12
+-- evHVACBardBlowDiff .2.12.19.2.2.13
+-- evHVACBardBlowDiffState .2.12.19.2.2.14
+-- evHVACBardOffDelay .2.12.19.2.2.15
+-- evHVACBardOffDelayState .2.12.19.2.2.16
+-- evHVACBardRunMin .2.12.19.2.2.17
+-- evHVACBardRunMinState .2.12.19.2.2.18
+-- evHVACBardDiff .2.12.19.2.2.19
+-- evHVACBardStage1Diff .2.12.19.2.2.19.1
+-- evHVACBardStage1DiffState .2.12.19.2.2.19.2
+-- evHVACBardStage2Diff .2.12.19.2.2.19.3
+-- evHVACBardStage2DiffState .2.12.19.2.2.19.4
+-- evHVACBardStage3Diff .2.12.19.2.2.19.5
+-- evHVACBardStage3DiffState .2.12.19.2.2.19.6
+-- evHVACBardCoolDisableDb .2.12.19.2.2.20
+-- evHVACBardCoolDisableDbState .2.12.19.2.2.21
+-- evHVACBardCoolEnableDb .2.12.19.2.2.22
+-- evHVACBardCoolEnableDbState .2.12.19.2.2.23
+-- evHVACBardHeatDb .2.12.19.2.2.24
+-- evHVACBardHeatDbState .2.12.19.2.2.25
+-- evHVACBardHeatPump .2.12.19.2.2.26
+-- evHVACBardHeatPumpState .2.12.19.2.2.27
+-- evHVACBardCompressors .2.12.19.2.2.28
+-- evHVACBardCompressorsState .2.12.19.2.2.29
+-- evHVACBardEconomizer .2.12.19.2.2.30
+-- evHVACBardEconomizerState .2.12.19.2.2.31
+-- evHVACBardTemp .2.12.19.2.2.32
+-- evHVACBardTempLowValue .2.12.19.2.2.32.1
+-- evHVACBardTempLowValueState .2.12.19.2.2.32.2
+-- evHVACBardTempHighValue .2.12.19.2.2.32.3
+-- evHVACBardTempHighValueState .2.12.19.2.2.32.4
+-- evHVACBardTempVHighValue .2.12.19.2.2.32.5
+-- evHVACBardTempVHighValueState .2.12.19.2.2.32.6
+-- evHVACBardOverride .2.12.19.2.2.33
+-- evHVACBardOverrideState .2.12.19.2.2.34
+-- evHVACBardLock .2.12.19.2.2.35
+-- evHVACBardLockState .2.12.19.2.2.36
+-- evHVACBardLeadUnit .2.12.19.2.2.37
+-- evHVACBardLeadUnitState .2.12.19.2.2.38
+-- evHVACBardComfort .2.12.19.2.2.39
+-- evHVACBardComfortState .2.12.19.2.2.40
+-- evHVACAsentria .2.12.19.3
+-- evHVACAsentriaSensorListTable .2.12.19.3.1
+-- evHVACAsentriaSensorListEntry .2.12.19.3.1.1
+-- evHVACAsentriaSensorListIndex .2.12.19.3.1.1.1
+-- evHVACAsentriaSensorListES .2.12.19.3.1.1.2
+-- evHVACAsentriaSensorListPT .2.12.19.3.1.1.3
+-- evHVACAsentriaSensorListType .2.12.19.3.1.1.4
+-- evHVACAsentriaSensorListLoc .2.12.19.3.1.1.5
+-- evHVACAsentriaOverride .2.12.19.3.2
+-- evHVACAsentriaSchedule .2.12.19.3.3
+-- evHVACAsentriaPrimary .2.12.19.3.4
+-- evHVACAsentriaMethod .2.12.19.3.5
+-- evHVACAsentriaAlarm .2.12.19.3.6
+-- evHVACAsentriaAlarmLagNormEnable .2.12.19.3.6.1
+-- evHVACAsentriaAlarmLagNormActions .2.12.19.3.6.2
+-- evHVACAsentriaAlarmLagNormTrapNum .2.12.19.3.6.3
+-- evHVACAsentriaAlarmLagNormClass .2.12.19.3.6.4
+-- evHVACAsentriaAlarmLagVentEnable .2.12.19.3.6.5
+-- evHVACAsentriaAlarmLagVentActions .2.12.19.3.6.6
+-- evHVACAsentriaAlarmLagVentTrapNum .2.12.19.3.6.7
+-- evHVACAsentriaAlarmLagVentClass .2.12.19.3.6.8
+-- evHVACAsentriaAlarmLagCoolEnable .2.12.19.3.6.9
+-- evHVACAsentriaAlarmLagCoolActions .2.12.19.3.6.10
+-- evHVACAsentriaAlarmLagCoolTrapNum .2.12.19.3.6.11
+-- evHVACAsentriaAlarmLagCoolClass .2.12.19.3.6.12
+-- evHVACAsentriaAlarmLagHeatEnable .2.12.19.3.6.13
+-- evHVACAsentriaAlarmLagHeatActions .2.12.19.3.6.14
+-- evHVACAsentriaAlarmLagHeatTrapNum .2.12.19.3.6.15
+-- evHVACAsentriaAlarmLagHeatClass .2.12.19.3.6.16
+-- evHVACAsentriaFire .2.12.19.3.7
+-- evHVACAsentriaFireES .2.12.19.3.7.1
+-- evHVACAsentriaFirePT .2.12.19.3.7.2
+-- evHVACAsentriaFireActions .2.12.19.3.7.3
+-- evHVACAsentriaFireTrapNum .2.12.19.3.7.4
+-- evHVACAsentriaFireClass .2.12.19.3.7.5
+-- evHVACAsentriaFireNormActions .2.12.19.3.7.6
+-- evHVACAsentriaFireNormTrapNum .2.12.19.3.7.7
+-- evHVACAsentriaFireNormClass .2.12.19.3.7.8
+-- evHVACAsentriaUnitTable .2.12.19.3.8
+-- evHVACAsentriaUnitEntry .2.12.19.3.8.1
+-- evHVACAsentriaUnitIndex .2.12.19.3.8.1.1
+-- evHVACAsentriaUnitEnable .2.12.19.3.8.1.2
+-- evHVACAsentriaUnitFanRelayES .2.12.19.3.8.1.3
+-- evHVACAsentriaUnitFanRelayPT .2.12.19.3.8.1.4
+-- evHVACAsentriaUnitVentRelayES .2.12.19.3.8.1.5
+-- evHVACAsentriaUnitVentRelayPT .2.12.19.3.8.1.6
+-- evHVACAsentriaUnitTimereset .2.12.19.3.8.1.7
+-- evHVACAsentriaSeqTimereset .2.12.19.3.8.1.8
+-- evHVACAsentriaUnitStage1CoolES .2.12.19.3.8.1.20
+-- evHVACAsentriaUnitStage1CoolPT .2.12.19.3.8.1.21
+-- evHVACAsentriaUnitStage1HeatES .2.12.19.3.8.1.22
+-- evHVACAsentriaUnitStage1HeatPT .2.12.19.3.8.1.23
+-- evHVACAsentriaUnitStage2CoolES .2.12.19.3.8.1.30
+-- evHVACAsentriaUnitStage2CoolPT .2.12.19.3.8.1.31
+-- evHVACAsentriaUnitStage2HeatES .2.12.19.3.8.1.32
+-- evHVACAsentriaUnitStage2HeatPT .2.12.19.3.8.1.33
+-- evHVACAsentriaTemp .2.12.19.3.9
+-- evHVACAsentriaTempScale .2.12.19.3.9.1
+-- evHVACAsentriaTempCoolThresh .2.12.19.3.9.2
+-- evHVACAsentriaTempHeatThresh .2.12.19.3.9.3
+-- evHVACAsentriaTempEnable .2.12.19.3.9.4
+-- evHVACAsentriaTempEventDeadband .2.12.19.3.9.5
+-- evHVACAsentriaTempVLowValue .2.12.19.3.9.6
+-- evHVACAsentriaTempVLowActions .2.12.19.3.9.7
+-- evHVACAsentriaTempVLowTrapNum .2.12.19.3.9.8
+-- evHVACAsentriaTempVLowClass .2.12.19.3.9.9
+-- evHVACAsentriaTempLowValue .2.12.19.3.9.10
+-- evHVACAsentriaTempLowActions .2.12.19.3.9.11
+-- evHVACAsentriaTempLowTrapNum .2.12.19.3.9.12
+-- evHVACAsentriaTempLowClass .2.12.19.3.9.13
+-- evHVACAsentriaTempNormalActions .2.12.19.3.9.14
+-- evHVACAsentriaTempNormalTrapNum .2.12.19.3.9.15
+-- evHVACAsentriaTempNormalClass .2.12.19.3.9.16
+-- evHVACAsentriaTempHighValue .2.12.19.3.9.17
+-- evHVACAsentriaTempHighActions .2.12.19.3.9.18
+-- evHVACAsentriaTempHighTrapNum .2.12.19.3.9.19
+-- evHVACAsentriaTempHighClass .2.12.19.3.9.20
+-- evHVACAsentriaTempVHighValue .2.12.19.3.9.21
+-- evHVACAsentriaTempVHighActions .2.12.19.3.9.22
+-- evHVACAsentriaTempVHighTrapNum .2.12.19.3.9.23
+-- evHVACAsentriaTempVHighClass .2.12.19.3.9.24
+-- evHVACAsentriaTempDeadband .2.12.19.3.9.25
+-- evHVACAsentriaTempDifference .2.12.19.3.9.26
+-- evHVACAsentriaHumid .2.12.19.3.10
+-- evHVACAsentriaHumidInThresh .2.12.19.3.10.2
+-- evHVACAsentriaHumidOutThresh .2.12.19.3.10.3
+-- evHVACAsentriaHumidEnable .2.12.19.3.10.4
+-- evHVACAsentriaHumidEventDeadband .2.12.19.3.10.5
+-- evHVACAsentriaHumidVLowValue .2.12.19.3.10.6
+-- evHVACAsentriaHumidVLowActions .2.12.19.3.10.7
+-- evHVACAsentriaHumidVLowTrapNum .2.12.19.3.10.8
+-- evHVACAsentriaHumidVLowClass .2.12.19.3.10.9
+-- evHVACAsentriaHumidLowValue .2.12.19.3.10.10
+-- evHVACAsentriaHumidLowActions .2.12.19.3.10.11
+-- evHVACAsentriaHumidLowTrapNum .2.12.19.3.10.12
+-- evHVACAsentriaHumidLowClass .2.12.19.3.10.13
+-- evHVACAsentriaHumidNormalActions .2.12.19.3.10.14
+-- evHVACAsentriaHumidNormalTrapNum .2.12.19.3.10.15
+-- evHVACAsentriaHumidNormalClass .2.12.19.3.10.16
+-- evHVACAsentriaHumidHighValue .2.12.19.3.10.17
+-- evHVACAsentriaHumidHighActions .2.12.19.3.10.18
+-- evHVACAsentriaHumidHighTrapNum .2.12.19.3.10.19
+-- evHVACAsentriaHumidHighClass .2.12.19.3.10.20
+-- evHVACAsentriaHumidVHighValue .2.12.19.3.10.21
+-- evHVACAsentriaHumidVHighActions .2.12.19.3.10.22
+-- evHVACAsentriaHumidVHighTrapNum .2.12.19.3.10.23
+-- evHVACAsentriaHumidVHighClass .2.12.19.3.10.24
+-- evHVACAsentriaHumidDeadband .2.12.19.3.10.25
+-- evHVACAsentriaHumidDifference .2.12.19.3.10.26
+-- evHVACAirsys .2.12.19.4
+-- evHVACAirsysGeneral .2.12.19.4.1
+-- evHVACAirsysGeneratorLogic .2.12.19.4.1.1
+-- evHVACAirsysFreeMode .2.12.19.4.1.2
+-- evHVACAirsysRemoteEnable .2.12.19.4.1.3
+-- evHVACAirsysHVACRotation .2.12.19.4.1.4
+-- evHVACAirsysRotationRuntime .2.12.19.4.1.5
+-- evHVACAirsysAlarm .2.12.19.4.2
+-- evHVACAirsysUnitTable .2.12.19.4.2.1
+-- evHVACAirsysUnitEntry .2.12.19.4.2.1.1
+-- evHVACAirsysUnitIndex .2.12.19.4.2.1.1.1
+-- evHVACAirsysULowPEnable .2.12.19.4.2.1.1.2
+-- evHVACAirsysULowPActions .2.12.19.4.2.1.1.3
+-- evHVACAirsysULowPClass .2.12.19.4.2.1.1.4
+-- evHVACAirsysULowPTrapNum .2.12.19.4.2.1.1.5
+-- evHVACAirsysULowPNormActions .2.12.19.4.2.1.1.6
+-- evHVACAirsysULowPNormClass .2.12.19.4.2.1.1.7
+-- evHVACAirsysULowPNormTrapNum .2.12.19.4.2.1.1.8
+-- evHVACAirsysUHighPEnable .2.12.19.4.2.1.1.9
+-- evHVACAirsysUHighPActions .2.12.19.4.2.1.1.10
+-- evHVACAirsysUHighPClass .2.12.19.4.2.1.1.11
+-- evHVACAirsysUHighPTrapNum .2.12.19.4.2.1.1.12
+-- evHVACAirsysUHighPNormActions .2.12.19.4.2.1.1.13
+-- evHVACAirsysUHighPNormClass .2.12.19.4.2.1.1.14
+-- evHVACAirsysUHighPNormTrapNum .2.12.19.4.2.1.1.15
+-- evHVACAirsysUEvapFanEnable .2.12.19.4.2.1.1.16
+-- evHVACAirsysUEvapFanActions .2.12.19.4.2.1.1.17
+-- evHVACAirsysUEvapFanClass .2.12.19.4.2.1.1.18
+-- evHVACAirsysUEvapFanTrapNum .2.12.19.4.2.1.1.19
+-- evHVACAirsysUEvapFanNormActions .2.12.19.4.2.1.1.20
+-- evHVACAirsysUEvapFanNormClass .2.12.19.4.2.1.1.21
+-- evHVACAirsysUEvapFanNormTrapNum .2.12.19.4.2.1.1.22
+-- evHVACAirsysUDirtyEnable .2.12.19.4.2.1.1.23
+-- evHVACAirsysUDirtyActions .2.12.19.4.2.1.1.24
+-- evHVACAirsysUDirtyClass .2.12.19.4.2.1.1.25
+-- evHVACAirsysUDirtyTrapNum .2.12.19.4.2.1.1.26
+-- evHVACAirsysUDirtyNormActions .2.12.19.4.2.1.1.27
+-- evHVACAirsysUDirtyNormClass .2.12.19.4.2.1.1.28
+-- evHVACAirsysUDirtyNormTrapNum .2.12.19.4.2.1.1.29
+-- evHVACAirsysUInProbeEnable .2.12.19.4.2.1.1.30
+-- evHVACAirsysUInProbeActions .2.12.19.4.2.1.1.31
+-- evHVACAirsysUInProbeClass .2.12.19.4.2.1.1.32
+-- evHVACAirsysUInProbeTrapNum .2.12.19.4.2.1.1.33
+-- evHVACAirsysUInProbeNormActions .2.12.19.4.2.1.1.34
+-- evHVACAirsysUInProbeNormClass .2.12.19.4.2.1.1.35
+-- evHVACAirsysUInProbeNormTrapNum .2.12.19.4.2.1.1.36
+-- evHVACAirsysUDamperEnable .2.12.19.4.2.1.1.37
+-- evHVACAirsysUDamperActions .2.12.19.4.2.1.1.38
+-- evHVACAirsysUDamperClass .2.12.19.4.2.1.1.39
+-- evHVACAirsysUDamperTrapNum .2.12.19.4.2.1.1.40
+-- evHVACAirsysUDamperNormActions .2.12.19.4.2.1.1.41
+-- evHVACAirsysUDamperNormClass .2.12.19.4.2.1.1.42
+-- evHVACAirsysUDamperNormTrapNum .2.12.19.4.2.1.1.43
+-- evHVACAirsysUSupProbeEnable .2.12.19.4.2.1.1.44
+-- evHVACAirsysUSupProbeActions .2.12.19.4.2.1.1.45
+-- evHVACAirsysUSupProbeClass .2.12.19.4.2.1.1.46
+-- evHVACAirsysUSupProbeTrapNum .2.12.19.4.2.1.1.47
+-- evHVACAirsysUSupProbeNormActions .2.12.19.4.2.1.1.48
+-- evHVACAirsysUSupProbeNormClass .2.12.19.4.2.1.1.49
+-- evHVACAirsysUSupProbeNormTrapNum .2.12.19.4.2.1.1.50
+-- evHVACAirsysSmokeFireEnable .2.12.19.4.2.2
+-- evHVACAirsysSmokeFireAction .2.12.19.4.2.3
+-- evHVACAirsysSmokeFireClass .2.12.19.4.2.4
+-- evHVACAirsysSmokeFireTrapNum .2.12.19.4.2.5
+-- evHVACAirsysSmokeFireNormAction .2.12.19.4.2.6
+-- evHVACAirsysSmokeFireNormClass .2.12.19.4.2.7
+-- evHVACAirsysSmokeFireNormTrapNum .2.12.19.4.2.8
+-- evHVACAirsysLowRoomTempEnable .2.12.19.4.2.9
+-- evHVACAirsysLowRoomTempAction .2.12.19.4.2.10
+-- evHVACAirsysLowRoomTempClass .2.12.19.4.2.11
+-- evHVACAirsysLowRoomTempTrapNum .2.12.19.4.2.12
+-- evHVACAirsysLowRoomTempNormAction .2.12.19.4.2.13
+-- evHVACAirsysLowRoomTempNormClass .2.12.19.4.2.14
+-- evHVACAirsysLowRoomTempNormTrapNum .2.12.19.4.2.15
+-- evHVACAirsysHighRoomTempEnable .2.12.19.4.2.16
+-- evHVACAirsysHighRoomTempAction .2.12.19.4.2.17
+-- evHVACAirsysHighRoomTempClass .2.12.19.4.2.18
+-- evHVACAirsysHighRoomTempTrapNum .2.12.19.4.2.19
+-- evHVACAirsysHighRoomTempNormAction .2.12.19.4.2.20
+-- evHVACAirsysHighRoomTempNormClass .2.12.19.4.2.21
+-- evHVACAirsysHighRoomTempNormTrapNum .2.12.19.4.2.22
+-- evHVACAirsysPowerEnable .2.12.19.4.2.23
+-- evHVACAirsysPowerAction .2.12.19.4.2.24
+-- evHVACAirsysPowerClass .2.12.19.4.2.25
+-- evHVACAirsysPowerTrapNum .2.12.19.4.2.26
+-- evHVACAirsysPowerNormAction .2.12.19.4.2.27
+-- evHVACAirsysPowerNormClass .2.12.19.4.2.28
+-- evHVACAirsysPowerNormTrapNum .2.12.19.4.2.29
+-- evHVACAirsyspLANEnable .2.12.19.4.2.30
+-- evHVACAirsyspLANAction .2.12.19.4.2.31
+-- evHVACAirsyspLANClass .2.12.19.4.2.32
+-- evHVACAirsyspLANTrapNum .2.12.19.4.2.33
+-- evHVACAirsyspLANNormAction .2.12.19.4.2.34
+-- evHVACAirsyspLANNormClass .2.12.19.4.2.35
+-- evHVACAirsyspLANNormTrapNum .2.12.19.4.2.36
+-- evHVACAirsysClockEnable .2.12.19.4.2.37
+-- evHVACAirsysClockAction .2.12.19.4.2.38
+-- evHVACAirsysClockClass .2.12.19.4.2.39
+-- evHVACAirsysClockTrapNum .2.12.19.4.2.40
+-- evHVACAirsysClockNormAction .2.12.19.4.2.41
+-- evHVACAirsysClockNormClass .2.12.19.4.2.42
+-- evHVACAirsysClockNormTrapNum .2.12.19.4.2.43
+-- evHVACAirsysHumidProbeEnable .2.12.19.4.2.44
+-- evHVACAirsysHumidProbeAction .2.12.19.4.2.45
+-- evHVACAirsysHumidProbeClass .2.12.19.4.2.46
+-- evHVACAirsysHumidProbeTrapNum .2.12.19.4.2.47
+-- evHVACAirsysHumidProbeNormAction .2.12.19.4.2.48
+-- evHVACAirsysHumidProbeNormClass .2.12.19.4.2.49
+-- evHVACAirsysHumidProbeNormTrapNum .2.12.19.4.2.50
+-- evHVACAirsysOutProbeEnable .2.12.19.4.2.51
+-- evHVACAirsysOutProbeAction .2.12.19.4.2.52
+-- evHVACAirsysOutProbeClass .2.12.19.4.2.53
+-- evHVACAirsysOutProbeTrapNum .2.12.19.4.2.54
+-- evHVACAirsysOutProbeNormAction .2.12.19.4.2.55
+-- evHVACAirsysOutProbeNormClass .2.12.19.4.2.56
+-- evHVACAirsysOutProbeNormTrapNum .2.12.19.4.2.57
+-- evHVACAirsysBothCompressEnable .2.12.19.4.2.58
+-- evHVACAirsysBothCompressAction .2.12.19.4.2.59
+-- evHVACAirsysBothCompressClass .2.12.19.4.2.60
+-- evHVACAirsysBothCompressTrapNum .2.12.19.4.2.61
+-- evHVACAirsysBothCompressNormAction .2.12.19.4.2.62
+-- evHVACAirsysBothCompressNormClass .2.12.19.4.2.63
+-- evHVACAirsysBothCompressNormTrapNum .2.12.19.4.2.64
+-- evHVACAirsysGeneratorEnable .2.12.19.4.2.65
+-- evHVACAirsysGeneratorAction .2.12.19.4.2.66
+-- evHVACAirsysGeneratorClass .2.12.19.4.2.67
+-- evHVACAirsysGeneratorTrapNum .2.12.19.4.2.68
+-- evHVACAirsysGeneratorNormAction .2.12.19.4.2.69
+-- evHVACAirsysGeneratorNormClass .2.12.19.4.2.70
+-- evHVACAirsysGeneratorNormTrapNum .2.12.19.4.2.71
+-- evHVACAirsysConnectionEnable .2.12.19.4.2.72
+-- evHVACAirsysConnectionAction .2.12.19.4.2.73
+-- evHVACAirsysConnectionClass .2.12.19.4.2.74
+-- evHVACAirsysConnectionTrapNum .2.12.19.4.2.75
+-- evHVACAirsysConnectionNormAction .2.12.19.4.2.76
+-- evHVACAirsysConnectionNormClass .2.12.19.4.2.77
+-- evHVACAirsysConnectionNormTrapNum .2.12.19.4.2.78
+-- evHVACAirsysTemp .2.12.19.4.3
+-- evHVACAirsysTempBaseThresh .2.12.19.4.3.1
+-- evHVACAirsysTempCoolDeadband .2.12.19.4.3.2
+-- evHVACAirsysTempHeatDeadband .2.12.19.4.3.3
+-- evHVACAirsysTempHighValue .2.12.19.4.3.4
+-- evHVACAirsysTempLowValue .2.12.19.4.3.5
+-- evHVACAirsysHumid .2.12.19.4.4
+-- evHVACAirsysHumidMaxFree .2.12.19.4.4.1
+-- evHVACAirsysHumidDeadband .2.12.19.4.4.2
+-- evEvps .2.12.20
+-- evpsEnable .2.12.20.1
+-- evpsIPAddress .2.12.20.2
+-- evpsPort .2.12.20.3
+-- evpsTimeout .2.12.20.4
+-- accessControl .2.12.21
+-- acActions .2.12.21.2
+-- acTrapnum .2.12.21.3
+-- acClass .2.12.21.4
+-- accessControlDeviceTable .2.12.21.10
+-- accessControlDeviceEntry .2.12.21.10.1
+-- acdIndex .2.12.21.10.1.1
+-- acdEnable .2.12.21.10.1.2
+-- acdName .2.12.21.10.1.3
+-- acdReader .2.12.21.10.1.4
+-- acdWiegandES .2.12.21.10.1.5
+-- acdWiegandPoint .2.12.21.10.1.6
+-- acdRelayType .2.12.21.10.1.7
+-- acdRelayES .2.12.21.10.1.8
+-- acdRelayPoint .2.12.21.10.1.9
+-- acdOpenTime .2.12.21.10.1.10
+-- acdUserGroup .2.12.21.10.1.11
+-- accessControlUserTable .2.12.21.11
+-- accessControlUserEntry .2.12.21.11.1
+-- acuIndexUserGroup .2.12.21.11.1.1
+-- acuIndexUser .2.12.21.11.1.2
+-- acuEnable .2.12.21.11.1.3
+-- acuName .2.12.21.11.1.4
+-- acuSn .2.12.21.11.1.5
+-- acuSunBegin .2.12.21.11.1.6
+-- acuSunEnd .2.12.21.11.1.7
+-- acuMonBegin .2.12.21.11.1.8
+-- acuMonEnd .2.12.21.11.1.9
+-- acuTueBegin .2.12.21.11.1.10
+-- acuTueEnd .2.12.21.11.1.11
+-- acuWedBegin .2.12.21.11.1.12
+-- acuWedEnd .2.12.21.11.1.13
+-- acuThuBegin .2.12.21.11.1.14
+-- acuThuEnd .2.12.21.11.1.15
+-- acuFriBegin .2.12.21.11.1.16
+-- acuFriEnd .2.12.21.11.1.17
+-- acuSatBegin .2.12.21.11.1.18
+-- acuSatEnd .2.12.21.11.1.19
+-- telemetry .2.12.22
+-- telemetryTable .2.12.22.1
+-- telemetryTableEntry .2.12.22.1.1
+-- telemetryPointIndex .2.12.22.1.1.1
+-- telemetryPointName .2.12.22.1.1.2
+-- telemetryPointKey .2.12.22.1.1.3
+-- telemetryPointType .2.12.22.1.1.4
+-- telemetryPointClass .2.12.22.1.1.5
+-- telemetryPointDeadband .2.12.22.1.1.6
+-- telemetryPointShortcode .2.12.22.1.1.7
+-- siteSecurity .2.12.23
+-- siteSecIntrusionTable .2.12.23.1
+-- siteSecEnable .2.12.23.1.1
+-- siteSecDisarmed .2.12.23.1.2
+-- siteSecName .2.12.23.1.3
+-- siteSecState .2.12.23.1.4
+-- siteSecSensorES .2.12.23.1.5
+-- siteSecSensorPoint .2.12.23.1.6
+-- siteSecIntrusionThreshold .2.12.23.1.7
+-- siteSecReader .2.12.23.1.8
+-- siteSecReaderThreshold .2.12.23.1.9
+-- siteSecButtonEnable .2.12.23.1.10
+-- siteSecButtonES .2.12.23.1.11
+-- siteSecButtonPoint .2.12.23.1.12
+-- siteSecButtonType .2.12.23.1.13
+-- siteSecButtonThresholdArm .2.12.23.1.14
+-- siteSecButtonThresholdDisarm .2.12.23.1.15
+-- siteSecSirenEnable .2.12.23.1.16
+-- siteSecSirenES .2.12.23.1.17
+-- siteSecSirenPoint .2.12.23.1.18
+-- siteSecRearmDelay .2.12.23.1.19
+-- siteSecMotionTable .2.12.23.2
+-- siteSecMotionES .2.12.23.2.1
+-- siteSecMotionPoint .2.12.23.2.2
+-- siteSecMotionEnable .2.12.23.2.3
+-- siteSecMotionName .2.12.23.2.4
+-- siteSecMotionThresholdRearm .2.12.23.2.5
+-- siteSecDoorAjarTable .2.12.23.3
+-- siteSecDoorAjarEnable .2.12.23.3.1
+-- siteSecDoorAjarName .2.12.23.3.2
+-- siteSecDoorAjarES .2.12.23.3.3
+-- siteSecDoorAjarPoint .2.12.23.3.4
+-- siteSecDoorAjarThresholdNormal .2.12.23.3.5
+-- siteSecDoorAjarThresholdExtraTime .2.12.23.3.6
+-- action .2.
+-- actionCallNumberTable .2.14.1
+-- actionCallNumberEntry .2.14.1.1
+-- actionCallNumberIndex .2.14.1.1.1
+-- actionCallNumber .2.14.1.1.2
+-- actionPagerTable .2.14.2
+-- actionPagerEntry .2.14.2.1
+-- actionPagerIndex .2.14.2.1.1
+-- actionPagerType .2.14.2.1.2
+-- actionPagerNumber .2.14.2.1.3
+-- actionPagerID .2.14.2.1.4
+-- actionPagerMessage .2.14.2.1.5
+-- actionPagerPostCalloutDelay .2.14.2.1.6
+-- actionPagerPostIDDelay .2.14.2.1.7
+-- actionSched .2.14.3
+-- actionSchedEnable .2.14.3.1
+-- actionSchedBegin .2.14.3.2
+-- actionSchedEnd .2.14.3.3
+-- actionSchedWeekdaysOnly .2.14.3.4
+-- actionAsentria .2.14.4
+-- actionAsentriaRequireAck .2.14.4.1
+-- actionAsentriaVersion .2.14.4.2
+-- actionAsentriaTCPPort .2.14.4.3
+-- actionHostTable .2.14.6
+-- actionHostEntry .2.14.6.1
+-- actionHostIndex .2.14.6.1.1
+-- actionHost .2.14.6.1.2
+-- actionEmailTable .2.14.7
+-- actionEmailEntry .2.14.7.1
+-- actionEmailIndex .2.14.7.1.1
+-- actionEmail .2.14.7.1.2
+-- actionParseError .2.14.8
+-- sys .2.16
+-- sysTime .2.16.1
+-- sysTimeAutoDST .2.16.1.1
+-- sysTimeGMTOffset .2.16.1.2
+-- sysTimeGMTDirection .2.16.1.3
+-- sysTimeNet .2.16.1.4
+-- sysTimeNetEnable .2.16.1.4.1
+-- sysTimeNetHostTable .2.16.1.4.2
+-- sysTimeNetHostEntry .2.16.1.4.2.1
+-- sysTimeNetHostIndex .2.16.1.4.2.1.1
+-- sysTimeNetHost .2.16.1.4.2.1.2
+-- sysPT .2.16.2
+-- sysPTTimeout .2.16.2.1
+-- sysPTEndPause .2.16.2.2
+-- sysPTJoinable .2.16.2.3
+-- sysMTU .2.16.3
+-- sysAnswerString .2.16.4
+-- sysEventFileID .2.16.6
+-- sysEscapeCharacter .2.16.7
+-- sysTimeStamp .2.16.8
+-- sysTimeStampTimeFormat .2.16.8.1
+-- sysTimeStampDateFormat .2.16.8.2
+-- sysTimeStampSpaceAfter .2.16.8.3
+-- sysLog .2.16.9
+-- sysLogMode .2.16.9.1
+-- sysLoghost .2.16.9.2
+-- sysLogFilter .2.16.9.3
+-- sysLogFileSize .2.16.9.4
+-- sysLogFileCount .2.16.9.5
+-- sysLogListenPort .2.16.9.6
+-- sysCRDB .2.16.10
+-- sysCRDBCapacity .2.16.10.1
+-- sysCRDBPercentFull .2.16.10.2
+-- sysCRDBFileIDTable .2.16.10.3
+-- sysCRDBFileIDEntry .2.16.10.3.1
+-- sysCRDBFileIDIndex .2.16.10.3.1.1
+-- sysCRDBFileID .2.16.10.3.1.2
+-- sysCRDBFileEnforceMinTable .2.16.10.4
+-- sysCRDBFileEnforceMinEntry .2.16.10.4.1
+-- sysCRDBFileEnforceMinIndex .2.16.10.4.1.1
+-- sysCRDBFileEnforceMin .2.16.10.4.1.2
+-- sysCharMask .2.16.11
+-- sysPrompt .2.16.12
+-- sysBootStatus .2.16.13
+-- sysLoc .2.16.14
+-- sysLocLatitude .2.16.14.1
+-- sysLocLongitude .2.16.14.2
+-- sysLocXOffset .2.16.14.3
+-- sysLocYOffset .2.16.14.4
+-- sysLocAngle .2.16.14.5
+-- sysLocAltitude .2.16.14.6
+-- sysAssetMgmt .2.16.15
+-- sysAMManufacturer .2.16.15.1
+-- sysAMProduct .2.16.15.2
+-- sysAMSerialNumber .2.16.15.3
+-- sysAMHardwareOptions .2.16.15.4
+-- sysAMSoftwareVersion .2.16.15.5
+-- sysAMSiteName .2.16.15.6
+-- sysFileTransfer .2.16.17
+-- sysFileTransferStatus .2.16.17.1
+-- sysFileTransferURL .2.16.17.2
+-- sysFileTransferUsername .2.16.17.3
+-- sysFileTransferPassword .2.16.17.4
+-- sysUpdate .2.16.18
+-- sysUpdateStatus .2.16.18.1
+-- auditLog .2.17
+-- auditLogEnable .2.17.1
+-- auditLogStoreResets .2.17.2
+-- auditLogStoreCommands .2.17.3
+-- auditLogStoreOutputs .2.17.4
+-- auditLogStoreAlarmActions .2.17.5
+-- auditLogStorePwdFailures .2.17.6
+-- auditLogStoreLogins .2.17.7
+-- auditLogStoreSHSK .2.17.8
+-- auditLogStorePassthrough .2.17.9
+-- auditLogStoreInactivity .2.17.10
+-- auditLogStorePolling .2.17.11
+-- auditLogMaxSize .2.17.12
+-- scripting .2.18
+-- scrGlobalEnable .2.18.1
+-- scrDTRCtrlPortEnableTable .2.18.2
+-- scrDTRCtrlPortEnableEnabletry .2.18.2.1
+-- scrDTRCtrlPortEnableIndex .2.18.2.1.1
+-- scrDTRCtrlPortEnable .2.18.2.1.2
+-- scrTable .2.18.3
+-- scrEntry .2.18.3.1
+-- scrIndex .2.18.3.1.1
+-- scrEnable .2.18.3.1.2
+-- scrName .2.18.3.1.3
+-- scrFilename .2.18.3.1.4
+-- scrRunAlways .2.18.3.1.5
+-- scrRunAtStartup .2.18.3.1.6
+-- scrRunScheduled .2.18.3.1.7
+-- scrScheduleTime .2.18.3.1.8
+-- scrArguments .2.18.3.1.9
+-- scrRepeatInterval .2.18.3.1.10
+-- scrVolatileStringTable .2.18.4
+-- scrVolatileStringEntry .2.18.4.1
+-- scrVolatileStringIndex .2.18.4.1.1
+-- scrVolatileString .2.18.4.1.2
+-- scrVolatileIntTable .2.18.5
+-- scrVolatileIntEntry .2.18.5.1
+-- scrVolatileIntIndex .2.18.5.1.1
+-- scrVolatileInt .2.18.5.1.2
+-- scrNonVolatileStringTable .2.18.6
+-- scrNonVolatileStringEntry .2.18.6.1
+-- scrNonVolatileStringIndex .2.18.6.1.1
+-- scrNonVolatileString .2.18.6.1.2
+-- scrNonVolatileIntTable .2.18.7
+-- scrNonVolatileIntEntry .2.18.7.1
+-- scrNonVolatileIntIndex .2.18.7.1.1
+-- scrNonVolatileInt .2.18.7.1.2
+-- generator .2.19
+-- genSet .2.19.1
+-- genSetEnable .2.19.1.1
+-- genSetRelay .2.19.1.2
+-- genSetRelayEs .2.19.1.2.1
+-- genSetRelayPoint .2.19.1.2.2
+-- genSetRelayRunningstate .2.19.1.2.3
+-- genSetRelayTable .2.19.1.2.5
+-- genSetRelayTableEntry .2.19.1.2.5.1
+-- genSetRelayTableIndex .2.19.1.2.5.1.1
+-- genSetRelayTableEnable .2.19.1.2.5.1.2
+-- genSetRelayTableEs .2.19.1.2.5.1.3
+-- genSetRelayTablePoint .2.19.1.2.5.1.4
+-- genSetRelayTableRunningstate .2.19.1.2.5.1.5
+-- genSetCc .2.19.1.3
+-- genSetCcEnable .2.19.1.3.1
+-- genSetCcEs .2.19.1.3.2
+-- genSetCcPoint .2.19.1.3.3
+-- genSetCcRunningstate .2.19.1.3.4
+-- genSetCCDelay .2.19.1.3.5
+-- genRun .2.19.2
+-- genRunMode .2.19.2.1
+-- genRunSched .2.19.2.2
+-- genRunDuration .2.19.2.3
+-- genRunForce .2.19.2.4
+-- genRunReqasm .2.19.2.5
+-- genRunStatus .2.19.2.6
+-- genRunNonstartEvent .2.19.2.7
+-- genRunNonstartEventEnable .2.19.2.7.1
+-- genRunNonstartEventActions .2.19.2.7.2
+-- genRunNonstartEventTrap .2.19.2.7.3
+-- genRunNonstartEventClass .2.19.2.7.4
+-- calendar .2.20
+-- schedTable .2.20.1
+-- schedEntry .2.20.1.1
+-- schedIndex .2.20.1.1.1
+-- schedEnable .2.20.1.1.2
+-- schedStart .2.20.1.1.3
+-- schedRepeatMode .2.20.1.1.4
+-- schedRepeatFreq .2.20.1.1.5
+-- schedRepeatEndMode .2.20.1.1.6
+-- schedRepeatEndAfter .2.20.1.1.7
+-- schedRepeatEndOn .2.20.1.1.8
+-- schedRepeatWeeklySun .2.20.1.1.9
+-- schedRepeatWeeklyMon .2.20.1.1.10
+-- schedRepeatWeeklyTue .2.20.1.1.11
+-- schedRepeatWeeklyWed .2.20.1.1.12
+-- schedRepeatWeeklyThu .2.20.1.1.13
+-- schedRepeatWeeklyFri .2.20.1.1.14
+-- schedRepeatWeeklySat .2.20.1.1.15
+-- schedRepeatMonthlyMode .2.20.1.1.16
+-- schedRepeatMonthlyDates .2.20.1.1.17
+-- schedRepeatMonthlyOnThe .2.20.1.1.18
+-- schedRepeatMonthlyOnDay .2.20.1.1.19
+-- schedRepeatYearlyJan .2.20.1.1.20
+-- schedRepeatYearlyFeb .2.20.1.1.21
+-- schedRepeatYearlyMar .2.20.1.1.22
+-- schedRepeatYearlyApr .2.20.1.1.23
+-- schedRepeatYearlyMay .2.20.1.1.24
+-- schedRepeatYearlyJun .2.20.1.1.25
+-- schedRepeatYearlyJul .2.20.1.1.26
+-- schedRepeatYearlyAug .2.20.1.1.27
+-- schedRepeatYearlySep .2.20.1.1.28
+-- schedRepeatYearlyOct .2.20.1.1.29
+-- schedRepeatYearlyNov .2.20.1.1.30
+-- schedRepeatYearlyDec .2.20.1.1.31
+-- schedRepeatYearlyOnThe .2.20.1.1.32
+-- schedRepeatYearlyOnDay .2.20.1.1.33
+-- schedNextTrigger .2.20.1.1.34
+
+-- productIds .3
+-- siteName 3.1
+-- thisProduct .3.2
+-- stockTrapString .3.3
+-- trapEventTypeNumber .3.4
+-- trapEventTypeName .3.5
+-- trapIncludedValue .3.6
+-- trapIncludedString .3.7
+-- trapTypeString .3.8
+-- trapEventClassNumber .3.9
+-- trapEventClassName .3.10
+
+-- keyInterface .4.0
+
+
+--***************************************************************************************
+--TOP-LEVEL OBJECT IDENTIFIERS
+--***************************************************************************************
+
+s550notifications OBJECT IDENTIFIER ::= { s550 0 }
+ --1.3.6.1.4.1.3052.10.0
+
+ status OBJECT IDENTIFIER ::= { s550 1 }
+ --1.3.6.1.4.1.3052.10.1
+
+ eventSensorStatus OBJECT IDENTIFIER ::= { status 1 }
+ --1.3.6.1.4.1.3052.10.1.1
+
+ dataEventStatus OBJECT IDENTIFIER ::= { status 2 }
+ --1.3.6.1.4.1.3052.10.1.2
+
+ powerDistributionStatus OBJECT IDENTIFIER ::= { status 5 }
+ --1.3.6.1.4.1.3052.10.1.5
+
+ pdNextGen OBJECT IDENTIFIER ::= { powerDistributionStatus 4 }
+ --1.3.6.1.4.1.3052.10.1.5.4
+
+ pdSystem OBJECT IDENTIFIER ::= { powerDistributionStatus 5 }
+ --1.3.6.1.4.1.3052.10.1.5.5
+
+ fuelSensorStatus OBJECT IDENTIFIER ::= { status 6 }
+ --1.3.6.1.4.1.3052.10.1.6
+
+ wirelessModemStatus OBJECT IDENTIFIER ::= { status 7 }
+ --1.3.6.1.4.1.3052.10.1.7
+
+ acPowerMonitorStatus OBJECT IDENTIFIER ::= { status 8 }
+ --1.3.6.1.4.1.3052.10.1.8
+
+ evHVACStatus OBJECT IDENTIFIER ::= { status 11 }
+ --1.3.6.1.4.1.3052.10.1.11
+
+ evHVACStatusBard OBJECT IDENTIFIER ::= { evHVACStatus 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2
+
+ evHVACStatusBardSystem1 OBJECT IDENTIFIER ::= { evHVACStatusBard 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.1
+
+ evHVACStatusBardSystem1Stage1 OBJECT IDENTIFIER ::= { evHVACStatusBardSystem1 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.1.1
+
+ evHVACStatusBardSystem1Stage2 OBJECT IDENTIFIER ::= { evHVACStatusBardSystem1 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.1.2
+
+ evHVACStatusBardSystem2 OBJECT IDENTIFIER ::= { evHVACStatusBard 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.2
+
+ evHVACStatusBardSystem2Stage1 OBJECT IDENTIFIER ::= { evHVACStatusBardSystem2 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.2.1
+
+ evHVACStatusBardSystem2Stage2 OBJECT IDENTIFIER ::= { evHVACStatusBardSystem2 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.2.2
+
+ evHVACStatusBardTempRemote OBJECT IDENTIFIER ::= { evHVACStatusBard 5 }
+ --1.3.6.1.4.1.3052.10.1.11.2.5
+
+ evHVACStatusBardLEDs OBJECT IDENTIFIER ::= { evHVACStatusBard 7 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.1
+
+ evHVACStatusBardLEDsCooling OBJECT IDENTIFIER ::= { evHVACStatusBardLEDs 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.1
+
+ evHVACStatusBardLEDsHeating OBJECT IDENTIFIER ::= { evHVACStatusBardLEDs 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.2
+
+ evHVACStatusBardLEDsDeHumid OBJECT IDENTIFIER ::= { evHVACStatusBardLEDs 3 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.3
+
+ evHVACStatusBardAlarmStatus OBJECT IDENTIFIER ::= { evHVACStatusBard 10 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10
+
+ evHVACStatusBardASSystem1 OBJECT IDENTIFIER ::= { evHVACStatusBardAlarmStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.1
+
+ evHVACStatusBardASSystem2 OBJECT IDENTIFIER ::= { evHVACStatusBardAlarmStatus 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.2
+
+ evHVACStatusBardASTemp OBJECT IDENTIFIER ::= { evHVACStatusBardAlarmStatus 4 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.4
+
+ evHVACStatusAsentria OBJECT IDENTIFIER ::= { evHVACStatus 3 }
+ --1.3.6.1.4.1.3052.10.1.11.3
+
+ evHVACStatusAsentriaTemp OBJECT IDENTIFIER ::= { evHVACStatusAsentria 5 }
+ --1.3.6.1.4.1.3052.10.1.11.3.5
+
+ evHVACStatusAsentriaHumid OBJECT IDENTIFIER ::= { evHVACStatusAsentria 6 }
+ --1.3.6.1.4.1.3052.10.1.11.3.6
+
+ evHVACStatusAirsys OBJECT IDENTIFIER ::= { evHVACStatus 4 }
+ --1.3.6.1.4.1.3052.10.1.11.4
+
+ evHVACStatusAirsysAlarm OBJECT IDENTIFIER ::= { evHVACStatusAirsys 1 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1
+
+ backupBattStatus OBJECT IDENTIFIER ::= { status 12 }
+ --1.3.6.1.4.1.3052.10.1.12
+
+ liBattStatus OBJECT IDENTIFIER ::= { backupBattStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.12.1
+ config OBJECT IDENTIFIER ::= { s550 2 }
+ --1.3.6.1.4.1.3052.10.2
+
+ eventSensorBasics OBJECT IDENTIFIER ::= { config 1 }
+ --1.3.6.1.4.1.3052.10.2.1
+
+ eventSensorPointConfig OBJECT IDENTIFIER ::= { config 2 }
+ --1.3.6.1.4.1.3052.10.2.2
+
+ serialPorts OBJECT IDENTIFIER ::= { config 3 }
+ --1.3.6.1.4.1.3052.10.2.3
+
+ network OBJECT IDENTIFIER ::= { config 4 }
+ --1.3.6.1.4.1.3052.10.2.4
+
+ interface OBJECT IDENTIFIER ::= { network 1 }
+ --1.3.6.1.4.1.3052.10.2.4
+
+ ethernet OBJECT IDENTIFIER ::= { interface 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1
+
+ ethernet1 OBJECT IDENTIFIER ::= { ethernet 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1
+
+ eth1VLAN OBJECT IDENTIFIER ::= { ethernet1 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.5
+
+ eth1VLAN1 OBJECT IDENTIFIER ::= { eth1VLAN 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.5.1
+
+ eth1VLAN2 OBJECT IDENTIFIER ::= { eth1VLAN 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.5.2
+
+ eth1VLAN3 OBJECT IDENTIFIER ::= { eth1VLAN 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.5.3
+
+ eth1VLAN4 OBJECT IDENTIFIER ::= { eth1VLAN 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.5.4
+
+ eth1VLAN5 OBJECT IDENTIFIER ::= { eth1VLAN 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.5.5
+
+ eth1VLAN6 OBJECT IDENTIFIER ::= { eth1VLAN 6 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.5.6
+
+ eth1IPv6 OBJECT IDENTIFIER ::= { ethernet1 7 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.7
+
+ eth1IPv6Static OBJECT IDENTIFIER ::= { eth1IPv6 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.7.2
+
+ eth1IPv6Auto OBJECT IDENTIFIER ::= { eth1IPv6 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.7.3
+
+ ethernet2 OBJECT IDENTIFIER ::= { ethernet 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2
+
+ eth2VLAN OBJECT IDENTIFIER ::= { ethernet2 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.5
+
+ eth2VLAN1 OBJECT IDENTIFIER ::= { eth2VLAN 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.5.1
+
+ eth2VLAN2 OBJECT IDENTIFIER ::= { eth2VLAN 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.5.2
+
+ eth2VLAN3 OBJECT IDENTIFIER ::= { eth2VLAN 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.5.3
+
+ eth2VLAN4 OBJECT IDENTIFIER ::= { eth2VLAN 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.5.4
+
+ eth2VLAN5 OBJECT IDENTIFIER ::= { eth2VLAN 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.5.5
+
+ eth2VLAN6 OBJECT IDENTIFIER ::= { eth2VLAN 6 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.5.6
+
+ eth2IPv6 OBJECT IDENTIFIER ::= { ethernet2 7 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.7
+
+ eth2IPv6Static OBJECT IDENTIFIER ::= { eth2IPv6 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.7.2
+
+ eth2IPv6Auto OBJECT IDENTIFIER ::= { eth2IPv6 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.2.7.3
+
+ snmp OBJECT IDENTIFIER ::= { network 8 }
+ --1.3.6.1.4.1.3052.10.2.4.8
+
+ snmpNotificationTx OBJECT IDENTIFIER ::= { snmp 7 }
+ --1.3.6.1.4.1.3052.10.2.4.8.7
+
+ snmpProxy OBJECT IDENTIFIER ::= { snmp 8 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8
+
+ snmpPoll OBJECT IDENTIFIER ::= { snmp 9 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9
+
+ ftpPush OBJECT IDENTIFIER ::= { network 9 }
+ --1.3.6.1.4.1.3052.10.2.4.9
+
+ ppp OBJECT IDENTIFIER ::= { network 10 }
+ --1.3.6.1.4.1.3052.10.2.4.10
+
+ pppDial OBJECT IDENTIFIER ::= { ppp 1 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1
+
+ pppHost OBJECT IDENTIFIER ::= { ppp 2 }
+ --1.3.6.1.4.1.3052.10.2.4.10.2
+
+ routing OBJECT IDENTIFIER ::= { network 11 }
+ --1.3.6.1.4.1.3052.10.2.4.11
+
+ netSecurity OBJECT IDENTIFIER ::= { network 12 }
+ --1.3.6.1.4.1.3052.10.2.4.12
+
+ ipRestriction OBJECT IDENTIFIER ::= { netSecurity 1 }
+ --1.3.6.1.4.1.3052.10.2.4.12.1
+
+ rts OBJECT IDENTIFIER ::= { network 13 }
+ --1.3.6.1.4.1.3052.10.2.4.13
+
+ rtsAlarms OBJECT IDENTIFIER ::= { rts 2 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2
+
+ trap OBJECT IDENTIFIER ::= { network 14 }
+ --1.3.6.1.4.1.3052.10.2.4.14
+
+ trapInclude OBJECT IDENTIFIER ::= { trap 1}
+ --1.3.6.1.4.1.3052.10.2.4.14.1
+
+ routeTest OBJECT IDENTIFIER ::= { network 15 }
+ --1.3.6.1.4.1.3052.10.2.4.15
+
+ wireless OBJECT IDENTIFIER ::= { network 16 }
+ --1.3.6.1.4.1.3052.10.2.4.16
+
+ wirelessConnectivity OBJECT IDENTIFIER ::= { wireless 20 }
+ --1.3.6.1.4.1.3052.10.2.4.16.20
+
+ email OBJECT IDENTIFIER ::= { network 17 }
+ --1.3.6.1.4.1.3052.10.2.4.17
+
+ netAdvanced OBJECT IDENTIFIER ::= { network 18 }
+ --1.3.6.1.4.1.3052.10.2.4.18
+
+ web OBJECT IDENTIFIER ::= { network 19 }
+ --1.3.6.1.4.1.3052.10.2.4.19
+
+ webXMLProxy OBJECT IDENTIFIER ::= { web 4 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4
+
+ ethExpan OBJECT IDENTIFIER ::= { network 20 }
+ --1.3.6.1.4.1.3052.10.2.4.20
+
+ ethExpanDHCP OBJECT IDENTIFIER ::= { ethExpan 6 }
+ --1.3.6.1.4.1.3052.10.2.4.20.6
+
+ ipv6 OBJECT IDENTIFIER ::= { network 21 }
+ --1.3.6.1.4.1.3052.10.2.4.21
+
+ cpe OBJECT IDENTIFIER ::= { network 22 }
+ --1.3.6.1.4.1.3052.10.2.4.22
+
+ dnp3 OBJECT IDENTIFIER ::= { network 23 }
+ --1.3.6.1.4.1.3052.10.2.4.23
+
+ dnp3General OBJECT IDENTIFIER ::= { dnp3 1 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1
+
+ dnp3Outstation OBJECT IDENTIFIER ::= { dnp3 2 }
+ --1.3.6.1.4.1.3052.10.2.4.23.2
+
+ dnp3Master OBJECT IDENTIFIER ::= { dnp3 3 }
+ --1.3.6.1.4.1.3052.10.2.4.23.3
+
+ dnp3Error OBJECT IDENTIFIER ::= { dnp3 4 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4
+
+ dnp3Status OBJECT IDENTIFIER ::= { dnp3 5 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5
+
+ modem OBJECT IDENTIFIER ::= { config 5 }
+ --1.3.6.1.4.1.3052.10.2.5
+
+ modemClid OBJECT IDENTIFIER ::= { modem 8 }
+ --1.3.6.1.4.1.3052.10.2.5.7
+
+ time OBJECT IDENTIFIER ::= { config 8 }
+ --1.3.6.1.4.1.3052.10.2.8
+
+ console OBJECT IDENTIFIER ::= { config 10 }
+ --1.3.6.1.4.1.3052.10.2.10
+
+ unitSecurity OBJECT IDENTIFIER ::= { config 11 }
+ --1.3.6.1.4.1.3052.10.2.11
+
+ secCore OBJECT IDENTIFIER ::= { unitSecurity 1 }
+ --1.3.6.1.4.1.3052.10.2.11.1
+
+ secFactory OBJECT IDENTIFIER ::= { unitSecurity 3 }
+ --1.3.6.1.4.1.3052.10.2.11.3
+
+ secSSH OBJECT IDENTIFIER ::= { unitSecurity 4 }
+ --1.3.6.1.4.1.3052.10.2.11.4
+
+ secVPN OBJECT IDENTIFIER ::= { unitSecurity 5 }
+ --1.3.6.1.4.1.3052.10.2.11.5
+
+ event OBJECT IDENTIFIER ::= { config 12 }
+ --1.3.6.1.4.1.3052.10.2.12
+
+ evCore OBJECT IDENTIFIER ::= { event 1 }
+ --1.3.6.1.4.1.3052.10.2.12.1
+
+ evLog OBJECT IDENTIFIER ::= { evCore 3 }
+ --1.3.6.1.4.1.3052.10.2.12.1.3
+
+ evMgmt OBJECT IDENTIFIER ::= { evCore 4 }
+ --1.3.6.1.4.1.3052.10.2.12.1.4
+
+ evData OBJECT IDENTIFIER ::= { event 2 }
+ --1.3.6.1.4.1.3052.10.2.12.1
+
+ evdCore OBJECT IDENTIFIER ::= { evData 1 }
+ --1.3.6.1.4.1.3052.10.2.12.2.1
+
+ evNoData1 OBJECT IDENTIFIER ::= { event 3 }
+ --1.3.6.1.4.1.3052.10.2.12.3
+
+ evNoData2 OBJECT IDENTIFIER ::= { event 4 }
+ --1.3.6.1.4.1.3052.10.2.12.4
+
+ evSched1 OBJECT IDENTIFIER ::= { event 5 }
+ --1.3.6.1.4.1.3052.10.2.12.5
+
+ evSched2 OBJECT IDENTIFIER ::= { event 6 }
+ --1.3.6.1.4.1.3052.10.2.12.6
+
+ evNoSensor OBJECT IDENTIFIER ::= { event 9 }
+ --1.3.6.1.4.1.3052.10.2.12.9
+
+ fuelSensor OBJECT IDENTIFIER ::= { event 11 }
+ --1.3.6.1.4.1.3052.10.2.12.11
+
+ acPowerMonitor OBJECT IDENTIFIER ::= { event 12 }
+ --1.3.6.1.4.1.3052.10.2.12.12
+
+ evReset OBJECT IDENTIFIER ::= { event 16 }
+ --1.3.6.1.4.1.3052.10.2.12.16
+
+ evGlobal OBJECT IDENTIFIER ::= { event 18 }
+ --1.3.6.1.4.1.3052.10.2.12.18
+
+ evHVAC OBJECT IDENTIFIER ::= { event 19 }
+ --1.3.6.1.4.1.3052.10.2.12.19
+
+ evHVACBard OBJECT IDENTIFIER ::= { evHVAC 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2
+
+ evHVACBardLocal OBJECT IDENTIFIER ::= { evHVACBard 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1
+
+ evHVACBardAlarm OBJECT IDENTIFIER ::= { evHVACBardLocal 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.7
+
+ evHVACBardSynchronized OBJECT IDENTIFIER ::= { evHVACBard 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2
+
+ evHVACBardDiff OBJECT IDENTIFIER ::= { evHVACBardSynchronized 19 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.19
+
+ evHVACBardTemp OBJECT IDENTIFIER ::= { evHVACBardSynchronized 32 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.32
+
+ evHVACAsentria OBJECT IDENTIFIER ::= { evHVAC 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3
+
+ evHVACAsentriaAlarm OBJECT IDENTIFIER ::= { evHVACAsentria 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6
+
+ evHVACAsentriaFire OBJECT IDENTIFIER ::= { evHVACAsentria 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7
+
+ evHVACAsentriaTemp OBJECT IDENTIFIER ::= { evHVACAsentria 9 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9
+
+ evHVACAsentriaHumid OBJECT IDENTIFIER ::= { evHVACAsentria 10 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.10
+
+ evHVACAirsys OBJECT IDENTIFIER ::= { evHVAC 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4
+
+ evHVACAirsysGeneral OBJECT IDENTIFIER ::= { evHVACAirsys 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.1
+
+ evHVACAirsysAlarm OBJECT IDENTIFIER ::= { evHVACAirsys 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2
+
+ evHVACAirsysTemp OBJECT IDENTIFIER ::= { evHVACAirsys 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.3
+
+ evHVACAirsysHumid OBJECT IDENTIFIER ::= { evHVACAirsys 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.4
+
+ evEvps OBJECT IDENTIFIER ::= { event 20 }
+ --1.3.6.1.4.1.3052.10.2.12.20
+
+ accessControl OBJECT IDENTIFIER ::= { event 21 }
+ --1.3.6.1.4.1.3052.10.2.12.21
+
+ telemetry OBJECT IDENTIFIER ::= { event 22 }
+ --1.3.6.1.4.1.3052.10.2.12.22
+
+ siteSecurity OBJECT IDENTIFIER ::= { event 23 }
+ --1.3.6.1.4.1.3052.10.2.12.23
+
+
+ action OBJECT IDENTIFIER ::= { config 14 }
+ --1.3.6.1.4.1.3052.10.2.14
+
+ actionSched OBJECT IDENTIFIER ::= { action 3 }
+ --1.3.6.1.4.1.3052.10.2.14.3
+
+ actionAsentria OBJECT IDENTIFIER ::= { action 4 }
+ --1.3.6.1.4.1.3052.10.2.14.4
+
+ sys OBJECT IDENTIFIER ::= { config 16 }
+ --1.3.6.1.4.1.3052.10.2.16
+
+ sysTime OBJECT IDENTIFIER ::= { sys 1 }
+ --1.3.6.1.4.1.3052.10.2.16.1
+
+ sysTimeNet OBJECT IDENTIFIER ::= { sysTime 4 }
+ --1.3.6.1.4.1.3052.10.2.16.1.4
+
+ sysPT OBJECT IDENTIFIER ::= { sys 2 }
+ --1.3.6.1.4.1.3052.10.2.16.2
+
+ sysTimeStamp OBJECT IDENTIFIER ::= { sys 8 }
+ --1.3.6.1.4.1.3052.10.2.16.8
+
+ sysLog OBJECT IDENTIFIER ::= { sys 9 }
+ --1.3.6.1.4.1.3052.10.2.16.9
+
+ sysCRDB OBJECT IDENTIFIER ::= { sys 10 }
+ --1.3.6.1.4.1.3052.10.2.16.10
+
+ sysLoc OBJECT IDENTIFIER ::= { sys 14 }
+ --1.3.6.1.4.1.3052.10.2.16.14
+
+ sysAssetMgmt OBJECT IDENTIFIER ::= { sys 15 }
+ --1.3.6.1.4.1.3052.10.2.16.15
+
+ sysFileTransfer OBJECT IDENTIFIER ::= { sys 17 }
+ --1.3.6.1.4.1.3052.10.2.16.17
+
+ sysUpdate OBJECT IDENTIFIER ::= { sys 18 }
+ --1.3.6.1.4.1.3052.10.2.16.18
+
+ auditLog OBJECT IDENTIFIER ::= { config 17 }
+ --1.3.6.1.4.1.3052.10.2.17
+
+ scripting OBJECT IDENTIFIER ::= { config 18 }
+ --1.3.6.1.4.1.3052.10.2.18
+
+ generator OBJECT IDENTIFIER ::= { config 19 }
+ --1.3.6.1.4.1.3052.10.2.19
+
+ genSet OBJECT IDENTIFIER ::= { generator 1 }
+ --1.3.6.1.4.1.3052.10.2.19.1
+
+ genSetRelay OBJECT IDENTIFIER ::= { genSet 2 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2
+
+ genSetCC OBJECT IDENTIFIER ::= { genSet 3 }
+ --1.3.6.1.4.1.3052.10.2.19.1.3
+
+ genRun OBJECT IDENTIFIER ::= { generator 2 }
+ --1.3.6.1.4.1.3052.10.2.19.2
+
+ genRunNonstartEvent OBJECT IDENTIFIER ::= { genRun 7 }
+ --1.3.6.1.4.1.3052.10.2.19.2.7
+
+ calendar OBJECT IDENTIFIER ::= { config 20 }
+ --1.3.6.1.4.1.3052.10.2.20
+
+ productIds OBJECT IDENTIFIER ::= { s550 3 }
+ --1.3.6.1.4.1.3052.10.3
+
+--***************************************************************************************
+--OBJECT DEFINITIONS
+--***************************************************************************************
+
+--***************************************************************************************
+--EventSensor Status Section 1.1
+--***************************************************************************************
+
+esPointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "
+ This table organizes 4 basic attributes of points. A point
+ is a particular sensor on an EventSensor (e.g., temperature,
+ humidity, contact closure 2, output 5, etc.). The 4 point
+ attributes are its name, whether it's in its event state,
+ the point's value as a number and its value as a string.
+
+ Points are referenced by a point index. The point index
+ is a string of 3 numbers separated by periods.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor; namely, which EventSensor,
+ point class, and which-sensor-of-that-class (a.k.a. point).
+ "
+ ::= { eventSensorStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.1.1
+
+esPointEntry OBJECT-TYPE
+ SYNTAX ESPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point table"
+ INDEX { esIndexES, esIndexPC, esIndexPoint }
+ ::= { esPointTable 1 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1
+
+esIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point index is a string of 3 numbers separated
+ by periods. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor; namely, which EventSensor, point class,
+ and which-sensor-of-that-class (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndexES=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esPointEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.1
+
+esIndexPC OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to point class.
+
+ The point index is a string of 3 numbers separated by periods.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor; namely, which EventSensor,
+ point class, and which-sensor-of-that-class (a.k.a. point).
+
+ The values for this object are:
+ 1=temperature sensor
+ 2=contact closure
+ 3=humidity sensor
+ 4=noise sensor
+ 5=analog input
+ 6=output (relay output or power output)
+ "
+ ::= { esPointEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.2
+
+esIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with esIndexPC (Point Class or type)
+ and esIndexES (which EventSensor) uniquely defines each
+ point (sensor or output) attached to a unit. For
+ example, if esIndexES is 3, esIndexPC is 1 and
+ esIndexPoint is 4 then this is the Fourth Temperature
+ Sensor on EventSensor number 3."
+ ::= { esPointEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.3
+
+esPointName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the point on an EventSensor. For example,
+ 'AC temp' (in the case of the temperature sensor on an
+ EventSensor).
+
+ There can be multiple points of the same point class on an
+ EventSensor (e.g., 8 contact closures) and multiple sensor
+ classes on an EventSensor (e.g., temperature, contact closure,
+ humidity).
+
+ If the point referenced by a given point index is solitary
+ (e.g., temperature sensor, because there can be only one on
+ an EventSensor), then this object reads as '<EventSensor
+ name>'. Setting this object for solitary point indices sets
+ the EventSensor name only.
+
+ On the other hand, if a given point is among other points of
+ the same point class on an EventSensor, then this object reads
+ as '<Sensor name>'. Setting this object for these NON-
+ solitary point indices sets the sensor name only - not the
+ EventSensor name."
+ ::= { esPointEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.4
+
+esPointInEventState OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A number referring to the event state of a point
+ on an EventSensor. This number can have different
+ meanings depending on the point class.
+
+ If the point class is temperature, humidity, or
+ analog input, then the values of this object are:
+ 1=very low
+ 2=low
+ 3=normal
+ 4=high
+ 5=very high
+
+ For contact closures the values of this object are:
+ 1=point in event state
+ 2=point in normal state
+
+ For outputs the values of this object is the numeric
+ code for the logical state of the output: 1 or 2. The
+ logical state of the output is either active/inactive for
+ relay outputs or on/off for power outputs. The logical
+ state of the output has different nomenclature depending
+ on the type of the output (relay output or power output):
+
+ 1=active (for relay output) or on (for power output)
+ 2=inactive (for relay output) or off (for power output)
+
+ This is not necessarily representative of physical state
+ of the output. Physical state is energized/de-energized,
+ for both relay and power outputs. For relay outputs,
+ the active logical state corresponds to either the energized
+ physical state or the de-energized physical state depending
+ on how the relay output is configured. For power outputs,
+ the on logical state always corresponds to the energized
+ physical state.
+
+ For any point class and any point, if the event
+ state is undefined, then the value of this object
+ is 0.
+
+ For any point class except output, this object is read-only.
+ For outputs, setting this object to 1 puts the output into
+ its active logical state.
+
+ Setting this object to 2 puts the output into its inactive
+ logical state.
+
+ Setting this object to any value greater than 2 puts the
+ output into its active logical state for that many seconds
+ (up to 3600), after which time it puts the output into its
+ inactive logical state.
+ "
+ ::= { esPointEntry 5 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.5
+
+esPointValueInt OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A read-only number referring to the value of a
+ point on an EventSensor.
+
+ If the point class is temperature, then this object
+ is the temperature in its configured scale (default
+ is Fahrenheit).
+
+ If the point class is contact closure, then
+ this object is either 0 (open) or 1 (closed).
+
+ If the point class is humidity, then this object
+ is the percent relative humidity.
+
+ If the point class is analog input, then this
+ object is the signed input value in tenths of the
+ configured units.
+
+ If the point class is an output, then this object is
+ the numeric code for the physical state of the output.
+ 0=de-energized
+ 1=energized
+
+ This object cannot be used to control the output, i.e,
+ change its logical or physical state (instead use
+ the esPointInEventState object).
+ "
+ ::= { esPointEntry 6 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.6
+
+esPointValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string referring to the value of a point on an
+ EventSensor.
+
+ For contact closures this object is either 'Open'
+ or 'Closed'.
+
+ For outputs this object is a concatenation of the
+ logical state and physical state, separated by '/'.
+
+ For a relay output this object can be one of the
+ following 4 possible values:
+
+ Active/Energized
+ Inactive/Energized
+ Active/De-energized
+ Inactve/De-energized
+
+ For a power output this object can be one of the
+ following 2 possible values:
+
+ On/Energized
+ Off/De-energized
+
+ For temperature and humidity point classes, this
+ object is the string representation of the
+ esPointValueInt object. For temperature, 'C' or
+ 'F' is including in the string to indicate scale.
+
+ For analog inputs, this object is the string
+ representation of the plus/minus input in the
+ configured units appended with the unit name.
+ "
+ ::= { esPointEntry 7 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.7
+
+esPointTimeLastChange OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last time an event was
+ triggerred for a point on an EventSensor in
+ MM/DD/YY HH:MM:SS format.
+
+ For contact closures, the possible events are
+ Active and Inactive. For temperature, humidity,
+ and analog inputs, the possible events are Normal,
+ High, Very High, Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { esPointEntry 8 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.8
+
+esPointTimetickLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last time an event was
+ triggerred for a point on an EventSensor in
+ 100ths of seconds since reset.
+
+ For contact closures, the possible events are
+ Active and Inactive. For temperature, humidity,
+ and analog inputs, the possible events are Normal,
+ High, Very High, Low, and Very Low.
+
+ For outputs, this object is 0."
+ ::= { esPointEntry 9 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.9
+
+esPointAliasValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For CC inputs, this is the CC active/inactive alias setting
+ setting value that currently corresponds to the event state.
+ So if the CC input is in the event state, then this object
+ is the active alias setting value. If the CC input is in the
+ normal state, then this object is the inactive alias setting
+ value.
+
+ For relay/power outputs, this is the output active/inactive
+ alias setting value that currently corresponds to the output
+ state. So if the output is in the active state, then this
+ object is the active alias setting value. If the output is
+ in hte inactive state, then this object is the inactive alias
+ setting value.
+
+ For non-CC and non-output sensors, this is the same as the
+ esPointValueStr object."
+ ::= { esPointEntry 10 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.10
+
+
+
+esPointClassValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For CC inputs, this is the CC active/inactive class setting
+ setting value that currently corresponds to the event state.
+ So if the CC input is in the event state, then this object
+ is the active class setting value. If the CC input is in the
+ normal state, then this object is the inactive class setting
+ value.
+
+ For relay/power, analog and temp outputs, this is the output
+ class string given the event (Very High, High, Normal, Low and
+ Very Low). The class string is based upon the chosen string in
+ the class table for e.g. Info, Minor, Major, Minor, Critical etc.
+ If the given event is High, the chosen Class string for this event
+ is what returned.
+ "
+ ::= { esPointEntry 11 }
+ --1.3.6.1.4.1.3052.10.1.1.1.1.11
+
+--***************************************************************************************
+--Data Event Status Section 1.2
+--***************************************************************************************
+
+deStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DEStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Data Event Status Table"
+ ::= { dataEventStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.2.1
+
+deStatusEntry OBJECT-TYPE
+ SYNTAX DEStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "EventSensor status entry"
+ INDEX { deStatusIndex }
+ ::= { deStatusTable 1 }
+ --1.3.6.1.4.1.3052.10.1.2.1.1
+
+deStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Data Events"
+ ::= { deStatusEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.2.1.1.1
+
+deStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Data Event name"
+ ::= { deStatusEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.2.1.1.2
+
+deStatusCounter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times a data record has matched this
+ event's equation.
+ Range: 1-999999999"
+ ::= { deStatusEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.2.1.1.3
+
+deStatusThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times the equation is matched before
+ an event is triggered.
+ Range: 1-999999999"
+ ::= { deStatusEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.2.1.1.4
+
+modemStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status of modem (idle, dialing, connected, etc.)"
+ ::= { status 3 }
+ --1.3.6.1.4.1.3052.10.1.3
+
+modemCLIDLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ModemCLIDLogConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of numbers of recent dialing parties"
+ ::= { status 4 }
+ --1.3.6.1.4.1.3052.10.1.4
+
+modemCLIDLogEntry OBJECT-TYPE
+ SYNTAX ModemCLIDLogConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CLID log entries"
+ INDEX { modemCLIDLogIndex }
+ ::= { modemCLIDLogTable 1 }
+ --1.3.6.1.4.1.3052.10.1.4.1
+
+modemCLIDLogIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CLID log entries"
+ ::= { modemCLIDLogEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.4.1.1
+
+modemCLIDLogNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "recently logged number of dialing party"
+ ::= { modemCLIDLogEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.4.1.2
+
+--***************************************************************************************
+--Power Distribution Status Section 1.5
+--***************************************************************************************
+
+pdConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution output configuration"
+ ::= { powerDistributionStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.5.1
+
+PowerDistribNextGen ::=
+ SEQUENCE {
+ pdnIndexPD
+ Integer32,
+ pdnIndexOutput
+ Integer32,
+ pdnConfig
+ DisplayString,
+ pdnMainCurrentInEventState
+ DisplayString,
+ pdnMainCurrentValue
+ Integer32,
+ pdnMainCurrentValueStr
+ DisplayString,
+ pdnMainCurrentDeadband
+ Integer32,
+ pdnMainCurrentVHighCurrent
+ Integer32,
+ pdnMainCurrentHighCurrent
+ Integer32,
+ pdnMainCurrentLowCurrent
+ Integer32,
+ pdnMainCurrentVLowCurrent
+ Integer32,
+ pdnMainVoltageInEventState
+ DisplayString,
+ pdnMainVoltageValue
+ Integer32,
+ pdnMainVoltageValueStr
+ DisplayString,
+ pdnMainVoltageDeadband
+ Integer32,
+ pdnMainVoltageVHighVoltage
+ Integer32,
+ pdnMainVoltageHighVoltage
+ Integer32,
+ pdnMainVoltageLowVoltage
+ Integer32,
+ pdnMainVoltageVLowVoltage
+ Integer32,
+ pdnMainPowerValue
+ Integer32,
+ pdnMainPowerValueStr
+ DisplayString,
+ pdnOutputCurrentInEventState
+ DisplayString,
+ pdnOutputCurrentValue
+ Integer32,
+ pdnOutputCurrentValueStr
+ DisplayString,
+ pdnOutputCurrentDeadband
+ Integer32,
+ pdnOutputCurrentVHighCurrent
+ Integer32,
+ pdnOutputCurrentHighCurrent
+ Integer32,
+ pdnOutputCurrentLowCurrent
+ Integer32,
+ pdnOutputCurrentVLowCurrent
+ Integer32,
+ pdnOutputFuseInEventState
+ DisplayString,
+ pdnOutputFuseValueStr
+ DisplayString,
+ pdnMainCombinedStatus
+ DisplayString,
+ pdnOutputCombinedStatusBlock1
+ DisplayString,
+ pdnOutputCombinedStatusBlock2
+ DisplayString,
+ pdnDeviceCurrentValue
+ Integer32,
+ pdnDeviceCurrentValueStr
+ DisplayString
+}
+
+pdnTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerDistribNextGen
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of power distribution objects arranged according
+ to next-generation methodology (i.e., using multiple PowerBoss
+ power distributors in addition to the on-board power
+ distributor)."
+ ::= { pdNextGen 1 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1
+
+pdnEntry OBJECT-TYPE
+ SYNTAX PowerDistribNextGen
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of power distribution objects arranged according
+ to next-generation methodology (i.e., using multiple PowerBoss
+ power distributors in addition to the on-board power
+ distributor)."
+ INDEX { pdnIndexPD, pdnIndexOutput }
+ ::= { pdnTable 1 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1
+
+pdnIndexPD OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power distribution objects, specifically the
+ index that refers to which power distributor. A value of 200 means
+ the internal power distributor. A value from 1 to 16 refers to an
+ external power distributor (PowerBoss), and is the same value as esIndexES,
+ which refers to the PowerBoss as an EventSensor in the eventSensorStatus
+ object table. In other words, pdnIndexPD is the same as esIndexES:
+ esIndexES is used to refer to the PowerBoss as an eventsensor (i.e., control
+ outputs), while pdnIndexPD is used to refer to the PowerBoss when used for
+ power distribution monitoring (i.e., to alarm on output
+ current/voltage/fuse status)."
+ ::= { pdnEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.1
+
+pdnIndexOutput OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power distribution objects, specifically the
+ index that refers to which output on the power distributor specified
+ by pdnIndexPD. For objects where the output is irrelevant, this index
+ should be 1."
+ ::= { pdnEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.2
+
+pdnConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs on the power distributor specified by pdnIndexPD.
+ pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.3
+
+pdnMainCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the current (i.e. Amps) event of the power distributor
+ specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
+ Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
+ 'Very High'."
+ ::= { pdnEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.4
+
+pdnMainCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current drawn, in mA, for the power distributor specified by pdnIndexPD.
+ If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss)
+ and refers to the current drawn by that PowerBoss and all equipment powered
+ by that PowerBoss. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 5 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.5
+
+pdnMainCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnMainCurrentValue formatted as a string in units of Amps, with
+ 3 decimal places. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 6 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.6
+
+pdnMainCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mA, for the main current sensor for the power distributor
+ specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 7 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.7
+
+pdnMainCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Very High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 8 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.8
+
+pdnMainCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 9 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.9
+
+pdnMainCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 10 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.10
+
+pdnMainCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Very Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 11 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.11
+
+pdnMainVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the voltage event of the power distributor
+ specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
+ Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
+ 'Very High'."
+ ::= { pdnEntry 12 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.12
+
+pdnMainVoltageValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, at the power distributor specified by pdnIndexPD.
+ If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss)
+ and refers to the voltage at that PowerBoss and all equipment powered by that
+ PowerBoss. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 13 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.13
+
+pdnMainVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnMainVoltageValue formatted as a string in units of Volts, with
+ 3 decimal places. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 14 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.14
+
+pdnMainVoltageDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mV, for the main voltage sensor for the power distributor
+ specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 15 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.15
+
+pdnMainVoltageVHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mA, for the main voltage sensor's Very High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 16 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.16
+
+pdnMainVoltageHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 17 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.17
+
+pdnMainVoltageLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 18 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.18
+
+pdnMainVoltageVLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's Very Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 19 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.19
+
+pdnMainPowerValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power, in Watts, for the power distributor specified by pdIndexPD.
+ pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 20 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.20
+
+pdnMainPowerValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power, in Watts, for the power distributor specified by pdIndexPD,
+ formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 21 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.21
+
+pdnOutputCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the current (i.e. Amps) event of the power distributor
+ output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200
+ and pdnIndexOutput=2, this refers to power output #2 of the internal power
+ distributor. Possible values for this object are: 'Very Low', 'Low', 'Normal',
+ 'High', 'Very High'."
+ ::= { pdnEntry 22 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.22
+
+pdnOutputCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current drawn, in mA, for the power distributor output specified by
+ pdnIndexPD and pdIndexOutput. E.g., if pdIndexPD is 3 then this is an external
+ power distributor (PowerBoss) identified as 'power distributor 3' and refers to
+ the current drawn by a specific power output on that PowerBoss. The specific
+ power output is specified by pdIndexOutput."
+ ::= { pdnEntry 23 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.23
+
+pdnOutputCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnOutputCurrentValue formatted as a string in units of Amps, with
+ 3 decimal places."
+ ::= { pdnEntry 24 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.24
+
+pdnOutputCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mA, for the main current sensor for the power distributor
+ specified by pdIndexPD. The power output is specified by pdnIndexOutput."
+ ::= { pdnEntry 25 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.25
+
+pdnOutputCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Very High
+ event threshold, for the power distributor specified by pdIndexPD. The power
+ output is specified by pdnIndexOutput."
+ ::= { pdnEntry 26 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.26
+
+pdnOutputCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor High event
+ threshold, for the power distributor specified by pdIndexPD. The power output
+ is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 27 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.27
+
+pdnOutputCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Low event
+ threshold, for the power distributor specified by pdIndexPD. The power output
+ is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 28 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.28
+
+pdnOutputCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Very Low
+ event threshold, for the power distributor specified by pdIndexPD. The power
+ output is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 29 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.29
+
+pdnOutputFuseInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the fuse event of the power distributor output specified
+ by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2,
+ this refers to power output #2 of the external power distributor (PowerBoss),
+ identified as 'power distributor 14'. Possible values for this object are:
+ 'Very Low', 'Low', 'Normal', 'High', 'Very High'. This object exists only for
+ power distributors with fuse monitoring support."
+ ::= { pdnEntry 30 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.30
+
+pdnOutputFuseValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the fuse of the power distributor output specified
+ by pdnIndexPD and pdnIndexOutput. Possible values for this object are:
+ 'BLOWN' and 'OK'. This object exists only for power distributors with fuse
+ monitoring support."
+ ::= { pdnEntry 31 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.31
+
+pdnMainCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValue"
+ ::= { pdnEntry 32 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.32
+
+pdnOutputCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
+ ::= { pdnEntry 33 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.33
+
+pdnOutputCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
+ ::= { pdnEntry 34 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.34
+
+pdnDeviceCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current drawn by device in mA. For the internal power distributor device,
+ this is the current drawn by the SiteBoss 571. For an external power
+ distributor device (PowerBoss), this is the current drawn by the
+ PowerBoss. This object exists only for power distributors with device
+ current monitoring support."
+ ::= { pdnEntry 35 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.35
+
+pdnDeviceCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current drawn by device as a string with units (Amps). For the internal
+ power distributor device, this is the current drawn by the SiteBoss 571.
+ For an external power distributor device (PowerBoss), this is the
+ current drawn by the PowerBoss. This object exists only for power
+ distributors with device current monitoring support."
+ ::= { pdnEntry 36 }
+ --1.3.6.1.4.1.3052.10.1.5.4.1.1.36
+
+pdSystemCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total current drawn by all power distributors in system; that is, the
+ sum of all pdnMainCurrentValue objects for all connected power
+ distributors: internal and external."
+ ::= { pdSystem 1 }
+ --1.3.6.1.4.1.3052.10.1.5.5.1
+
+pdSystemPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power used by all power distributors in system; that is, the
+ sum of all pdnMainPowerValue objects for all connected power
+ distributors: internal and external."
+ ::= { pdSystem 2 }
+ --1.3.6.1.4.1.3052.10.1.5.5.2
+
+
+--***************************************************************************************
+--Fuel Sensor 1.6
+--***************************************************************************************
+
+fsStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FSStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor status table"
+ ::= { fuelSensorStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.6.1
+
+fsStatusEntry OBJECT-TYPE
+ SYNTAX FSStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor status table entry"
+ INDEX { fsStatusIndex }
+ ::= { fsStatusTable 1 }
+ --1.3.6.1.4.1.3052.10.1.6.1.1
+
+fsStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for fuel sensors"
+ ::= { fsStatusEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.6.1.1.1
+
+fsStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor name"
+ ::= { fsStatusEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.6.1.1.2
+
+fsStatusDeviceState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor device state"
+ ::= { fsStatusEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.6.1.1.3
+
+fsStatusVolumeValueString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads
+ -999 when the fuel sensor is disconnected"
+ ::= { fsStatusEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.6.1.1.4
+
+fsStatusVolumePercentLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Height of the fluid in the tank expressed as a percentage of the tank
+ height, in hundredths of a percent."
+ ::= { fsStatusEntry 7 }
+ --1.3.6.1.4.1.3052.10.1.6.1.1.7
+
+fsStatusVolumeInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current event status of the fuel sensor."
+ ::= { fsStatusEntry 8 }
+ --1.3.6.1.4.1.3052.10.1.6.1.1.8
+
+fsStatusCombined OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`name"
+ ::= { fsStatusEntry 9 }
+ --1.3.6.1.4.1.3052.10.1.6.1.1.9
+
+--***************************************************************************************
+--Wireless Modem Status Section 1.7
+--***************************************************************************************
+
+wmsStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem status"
+ ::= { wirelessModemStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.7.1
+
+wmsSignal OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Signal strength"
+ ::= { wirelessModemStatus 2 }
+ --1.3.6.1.4.1.3052.10.1.7.2
+
+wmsRSSI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Signal strength (RSSI)"
+ ::= { wirelessModemStatus 3 }
+ --1.3.6.1.4.1.3052.10.1.7.3
+
+wmsBER OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Bit Error Rate"
+ ::= { wirelessModemStatus 4 }
+ --1.3.6.1.4.1.3052.10.1.7.4
+
+wmsUpdated OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem info last update time"
+ ::= { wirelessModemStatus 5 }
+ --1.3.6.1.4.1.3052.10.1.7.5
+
+wmsRegistration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem registration status"
+ ::= { wirelessModemStatus 6 }
+ --1.3.6.1.4.1.3052.10.1.7.6
+
+wmsLAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Location Area Code"
+ ::= { wirelessModemStatus 7 }
+ --1.3.6.1.4.1.3052.10.1.7.7
+
+wmsCellID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Cell ID"
+ ::= { wirelessModemStatus 8 }
+ --1.3.6.1.4.1.3052.10.1.7.8
+
+wmsIMSI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Internation Mobile Subscriber Identity number"
+ ::= { wirelessModemStatus 9 }
+ --1.3.6.1.4.1.3052.10.1.7.9
+
+wmsPhnum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem phone number"
+ ::= { wirelessModemStatus 10 }
+ --1.3.6.1.4.1.3052.10.1.7.10
+
+wmsLocalIP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Local IP address of modem on wireless network"
+ ::= { wirelessModemStatus 11 }
+ --1.3.6.1.4.1.3052.10.1.7.11
+
+wmsMgfID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem manufacturer ID"
+ ::= { wirelessModemStatus 12 }
+ --1.3.6.1.4.1.3052.10.1.7.12
+
+wmsModelID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem model ID"
+ ::= { wirelessModemStatus 13 }
+ --1.3.6.1.4.1.3052.10.1.7.13
+
+wmsIMEI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem International Mobile Equipment Identity number"
+ ::= { wirelessModemStatus 14 }
+ --1.3.6.1.4.1.3052.10.1.7.14
+
+wmsRevID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem revision ID"
+ ::= { wirelessModemStatus 15 }
+ --1.3.6.1.4.1.3052.10.1.7.15
+
+wmsNetName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem network name"
+ ::= { wirelessModemStatus 16 }
+ --1.3.6.1.4.1.3052.10.1.7.16
+
+wmsGPRSStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem (E)GPRS status"
+ ::= { wirelessModemStatus 17 }
+ --1.3.6.1.4.1.3052.10.1.7.17
+
+wmsBand OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem band"
+ ::= { wirelessModemStatus 18 }
+ --1.3.6.1.4.1.3052.10.1.7.18
+
+wmsChannel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem channel"
+ ::= { wirelessModemStatus 19 }
+ --1.3.6.1.4.1.3052.10.1.7.19
+
+wmsCountryCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem country code"
+ ::= { wirelessModemStatus 20 }
+ --1.3.6.1.4.1.3052.10.1.7.20
+
+wmsNetCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem network code"
+ ::= { wirelessModemStatus 21 }
+ --1.3.6.1.4.1.3052.10.1.7.21
+
+wmsPLMNColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem PLMN color"
+ ::= { wirelessModemStatus 22 }
+ --1.3.6.1.4.1.3052.10.1.7.22
+
+wmsBScolor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem BS color"
+ ::= { wirelessModemStatus 23 }
+ --1.3.6.1.4.1.3052.10.1.7.23
+
+wmsMpRACH OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem max power RACH"
+ ::= { wirelessModemStatus 24 }
+ --1.3.6.1.4.1.3052.10.1.7.24
+
+wmsMinRxLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem minimum receive level"
+ ::= { wirelessModemStatus 25 }
+ --1.3.6.1.4.1.3052.10.1.7.25
+
+wmsBaseCoeff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem base coefficient"
+ ::= { wirelessModemStatus 26 }
+ --1.3.6.1.4.1.3052.10.1.7.26
+
+wmsSIMStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "WWireless modem SIM status"
+ ::= { wirelessModemStatus 27 }
+ --1.3.6.1.4.1.3052.10.1.7.27
+
+wmsICCID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem SIM ICCID"
+ ::= { wirelessModemStatus 28 }
+ --1.3.6.1.4.1.3052.10.1.7.28
+
+wmsModemType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem type"
+ ::= { wirelessModemStatus 29 }
+ --1.3.6.1.4.1.3052.10.1.7.29
+
+
+--***************************************************************************************
+--AC Power Monitor Section 1.8
+--***************************************************************************************
+
+acpmStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "AC power monitor status table"
+ ::= { acPowerMonitorStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.8.1
+
+acpmStatusEntry OBJECT-TYPE
+ SYNTAX ACPMStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "AC power monitor status table entry"
+ INDEX { acpmsIndex }
+ ::= { acpmStatusTable 1 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1
+
+acpmsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AC power monitors"
+ ::= { acpmStatusEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.1
+
+acpmsName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name for the AC power monitor device."
+ ::= { acpmStatusEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.2
+
+acpmsAvgVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1). This could be either the average of
+ the phase voltages, or the sum of the phase voltages, depending
+ on device configuration."
+ ::= { acpmStatusEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.3
+
+acpmsAvgVoltageMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum average voltage value since last reset, in volts."
+ ::= { acpmStatusEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.4
+
+acpmsAvgVoltageMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum average voltage value since last reset, in volts."
+ ::= { acpmStatusEntry 5 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.5
+
+acpmsAvgVoltageAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average average voltage value since last reset, in volts. This is
+ the unit's average of its measurements of the average voltage
+ reported by the AC power monitor device."
+ ::= { acpmStatusEntry 6 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.6
+
+acpmsAvgVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor voltage (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 7 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.7
+
+acpmsVoltagePhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 8 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.8
+
+acpmsVoltagePhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 9 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.9
+
+acpmsVoltagePhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 10 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.10
+
+acpmsVoltageL1L2Value OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Line 1 to Line 2 voltage"
+ ::= { acpmStatusEntry 11 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.11
+
+acpmsVoltageL2L3Value OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Line 2 to Line 3 voltage"
+ ::= { acpmStatusEntry 12 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.12
+
+acpmsVoltageL3L1Value OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Line 3 to Line 1 voltage"
+ ::= { acpmStatusEntry 13 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.13
+
+
+acpmsAvgCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001). This could be either the average of
+ the phase currents, or the sum of the phase currents, depending on
+ device configuration."
+ ::= { acpmStatusEntry 14 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.14
+
+acpmsAvgCurrentMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum average current value since last reset, in amps."
+ ::= { acpmStatusEntry 15 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.15
+
+acpmsAvgCurrentMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum average current value since last reset, in amps."
+ ::= { acpmStatusEntry 16 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.16
+
+acpmsAvgCurrentAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average average current value since last reset, in amps. This is
+ the unit's average of its measurements of the average current reported
+ by the AC power monitor device."
+ ::= { acpmStatusEntry 17 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.17
+
+acpmsAvgCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor current (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 18 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.18
+
+acpmsCurrentPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 19 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.19
+
+acpmsCurrentPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 20 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.20
+
+acpmsCurrentPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 21 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.21
+
+acpmsAvgFreqValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency, in hertz. On the YD2010, this is calculated using the
+ formula (register * 0.00106813). On the WattsOn, this is calculated
+ using the formula (register * 0.1)."
+ ::= { acpmStatusEntry 22 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.22
+
+acpmsAvgFreqMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum frequency value since last reset, in hertz."
+ ::= { acpmStatusEntry 23 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.23
+
+acpmsAvgFreqMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum frequency value since last reset, in hertz."
+ ::= { acpmStatusEntry 24 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.24
+
+acpmsAvgFreqAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average frequency value since last reset, in hertz. This is the
+ unit's average of its measurements of the average frequency reported
+ by the AC power monitor device."
+ ::= { acpmStatusEntry 25 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.25
+
+acpmsAvgFreqInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor frequency (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 26 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.26
+
+acpmsTRPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn models,
+ this is calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 27 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.27
+
+acpmsTRPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum total real power value since last reset, in watts."
+ ::= { acpmStatusEntry 28 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.28
+
+acpmsTRPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum total real power value since last reset, in watts."
+ ::= { acpmStatusEntry 29 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.29
+
+acpmsTRPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average total real power value since last reset, in watts. This is
+ the unit's average of its measurements of the average total real power
+ reported by the AC power monitor device."
+ ::= { acpmStatusEntry 30 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.30
+
+acpmsTRPInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor total real power (Low, Normal,
+ High, etc.)."
+ ::= { acpmStatusEntry 31 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.31
+
+acpmsRPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 32 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.32
+
+acpmsRPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 33 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.33
+
+acpmsRPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 34 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.34
+
+acpmsCombined OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`freuencyColorCode`powerEventState`powerColorCode"
+ ::= { acpmStatusEntry 35 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.35
+
+acpmsTPFValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor."
+ ::= { acpmStatusEntry 36 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.36
+
+acpmsTPFMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor minimum value since last reset."
+ ::= { acpmStatusEntry 37 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.37
+
+acpmsTPFMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor maximum value since last reset."
+ ::= { acpmStatusEntry 38 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.38
+
+acpmsTPFAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor average value since last reset."
+ ::= { acpmStatusEntry 39 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.39
+
+acpmsTPFInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor event state."
+ ::= { acpmStatusEntry 40 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.40
+
+acpmsPFPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A power factor."
+ ::= { acpmStatusEntry 41 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.41
+
+acpmsPFPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B power factor."
+ ::= { acpmStatusEntry 42 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.42
+
+acpmsPFPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C power factor."
+ ::= { acpmStatusEntry 43 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.43
+
+acpmsTRcPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power, in VAR."
+ ::= { acpmStatusEntry 44 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.44
+
+acpmsTRcPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power minimum value since last reset, in VAR."
+ ::= { acpmStatusEntry 45 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.45
+
+acpmsTRcPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power maximum value since last reset, in VAR."
+ ::= { acpmStatusEntry 46 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.46
+
+acpmsTRcPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power average value since last reset, in VAR."
+ ::= { acpmStatusEntry 47 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.47
+
+acpmsRcPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A reactive power, in VAR."
+ ::= { acpmStatusEntry 48 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.48
+
+acpmsRcPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B reactive power, in VAR."
+ ::= { acpmStatusEntry 49 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.49
+
+acpmsRcPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C reactive power, in VAR."
+ ::= { acpmStatusEntry 50 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.50
+
+acpmsTAPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power, in VA."
+ ::= { acpmStatusEntry 51 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.51
+
+acpmsTAPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power minimum value since last reset, in VA."
+ ::= { acpmStatusEntry 52 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.52
+
+acpmsTAPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power maximum value since last reset, in VA."
+ ::= { acpmStatusEntry 53 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.53
+
+acpmsTAPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power average value since last reset, in VA."
+ ::= { acpmStatusEntry 54 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.54
+
+acpmsAPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A apparent power, in VA."
+ ::= { acpmStatusEntry 55 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.55
+
+acpmsAPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B apparent power, in VA."
+ ::= { acpmStatusEntry 56 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.56
+
+acpmsAPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C apparent power, in VA."
+ ::= { acpmStatusEntry 57 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.57
+
+acpmsTotalEnergyWh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total energy, in Wh."
+ ::= { acpmStatusEntry 58 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.58
+
+acpmsTotalEnergyVAR OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive energy, in VAR."
+ ::= { acpmStatusEntry 59 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.59
+
+acpmsTotalEnergyVA OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent energy, in VA."
+ ::= { acpmStatusEntry 60 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.60
+
+acmpsAvgVoltageAlarmDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last Average Voltage alarm
+ triggerred in the AC monitor
+ MM/DD/YY HH:MM:SS format.
+
+ The possible events are High, Very High,
+ Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { acpmStatusEntry 61 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.61
+
+acmpsAvgCurrentAlarmDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last Average Current alarm
+ triggerred in the AC monitor
+ MM/DD/YY HH:MM:SS format.
+
+ The possible events are High, Very High,
+ Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { acpmStatusEntry 62 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.62
+
+acmpsFreqAlarmDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last Frequency alarm
+ triggerred in the AC monitor
+ MM/DD/YY HH:MM:SS format.
+
+ The possible events are High, Very High,
+ Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { acpmStatusEntry 63 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.63
+
+acmpsRealPowerAlarmDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last Real Power alarm
+ triggerred in the AC monitor
+ MM/DD/YY HH:MM:SS format.
+
+ The possible events are High, Very High,
+ Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { acpmStatusEntry 64 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.64
+
+acmpsPowerFactorAlarmDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last Power Factor alarm
+ triggerred in the AC monitor
+ MM/DD/YY HH:MM:SS format.
+
+ The possible events are Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { acpmStatusEntry 65 }
+ --1.3.6.1.4.1.3052.10.1.8.1.1.66
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+--***************************************************************************************
+--HVAC Status Section 1.11
+--***************************************************************************************
+--***************************************************************************************
+--Asentria HVAC Status Section 1.11.2
+--***************************************************************************************
+
+evHVACStatusBardSystem1Stage1Cooling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 1 stage 1 cooling status."
+ ::= { evHVACStatusBardSystem1Stage1 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.1.1.1
+
+evHVACStatusBardSystem1Stage2Cooling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 1 stage 2 cooling status."
+ ::= { evHVACStatusBardSystem1Stage2 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.1.2.1
+
+evHVACStatusBardSystem1Blower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 1 blower status."
+ ::= { evHVACStatusBardSystem1 3 }
+ --1.3.6.1.4.1.3052.10.1.11.2.1.3
+
+evHVACStatusBardSystem1Heating OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 1 heating status."
+ ::= { evHVACStatusBardSystem1 4 }
+ --1.3.6.1.4.1.3052.10.1.11.2.1.4
+
+evHVACStatusBardSystem1Economizer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 1 heating status."
+ ::= { evHVACStatusBardSystem1 5 }
+ --1.3.6.1.4.1.3052.10.1.11.2.1.5
+
+evHVACStatusBardSystem2Stage1Cooling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 2 stage 1 cooling status."
+ ::= { evHVACStatusBardSystem2Stage1 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.2.1.1
+
+evHVACStatusBardSystem2Stage2Cooling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 2 stage 2 cooling status."
+ ::= { evHVACStatusBardSystem2Stage2 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.2.2.1
+
+evHVACStatusBardSystem2Blower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 2 blower status."
+ ::= { evHVACStatusBardSystem2 3 }
+ --1.3.6.1.4.1.3052.10.1.11.2.2.3
+
+evHVACStatusBardSystem2Heating OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 2 heating status."
+ ::= { evHVACStatusBardSystem2 4 }
+ --1.3.6.1.4.1.3052.10.1.11.2.2.4
+
+evHVACStatusBardSystem2Economizer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: System 2 heating status."
+ ::= { evHVACStatusBardSystem2 5 }
+ --1.3.6.1.4.1.3052.10.1.11.2.2.5
+
+evHVACStatusBardTempAvg OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Average temperature."
+ ::= { evHVACStatusBard 3 }
+ --1.3.6.1.4.1.3052.10.1.11.2.3
+
+evHVACStatusBardTempLocal OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Local temperature."
+ ::= { evHVACStatusBard 4 }
+ --1.3.6.1.4.1.3052.10.1.11.2.4
+
+evHVACStatusBardTempRemote1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Remote 1 temperature."
+ ::= { evHVACStatusBardTempRemote 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.5.1
+
+evHVACStatusBardTempRemote2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Remote 2 temperature."
+ ::= { evHVACStatusBardTempRemote 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.5.2
+
+evHVACStatusBardDehumidification OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Dehumidification status."
+ ::= { evHVACStatusBard 6 }
+ --1.3.6.1.4.1.3052.10.1.11.2.6
+
+evHVACStatusBardLEDsCooling1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Cooling LED 1."
+ ::= { evHVACStatusBardLEDsCooling 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.1.1
+
+evHVACStatusBardLEDsCooling2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Cooling LED 2."
+ ::= { evHVACStatusBardLEDsCooling 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.1.2
+
+evHVACStatusBardLEDsCooling3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Cooling LED 3."
+ ::= { evHVACStatusBardLEDsCooling 3 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.1.3
+
+evHVACStatusBardLEDsCooling4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Cooling LED 4."
+ ::= { evHVACStatusBardLEDsCooling 4 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.1.4
+
+evHVACStatusBardLEDsHeating1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Heating LED 1."
+ ::= { evHVACStatusBardLEDsHeating 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.2.1
+
+evHVACStatusBardLEDsHeating2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Heating LED 2."
+ ::= { evHVACStatusBardLEDsHeating 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.2.2
+
+evHVACStatusBardLEDsHeating3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Heating LED 3."
+ ::= { evHVACStatusBardLEDsHeating 3 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.2.3
+
+evHVACStatusBardLEDsHeating4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Heating LED 4."
+ ::= { evHVACStatusBardLEDsHeating 4 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.2.4
+
+evHVACStatusBardLEDsDeHumid1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Dehumidification LED 1."
+ ::= { evHVACStatusBardLEDsDeHumid 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.7.3.1
+
+evHVACStatusBardGenerator OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Backup generator status."
+ ::= { evHVACStatusBard 7 }
+ --1.3.6.1.4.1.3052.10.1.11.2.8
+
+evHVACStatusBardAlarmBoardState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC: Alarm board state."
+ ::= { evHVACStatusBard 8 }
+ --1.3.6.1.4.1.3052.10.1.11.2.9
+
+evHVACStatusBardASSystem1PowerLoss OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: System 1 power loss."
+ ::= { evHVACStatusBardASSystem1 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.1.1
+
+evHVACStatusBardASSystem1Lockout OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: System 1 ref. lockout."
+ ::= { evHVACStatusBardASSystem1 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.1.2
+
+evHVACStatusBardASSystem2PowerLoss OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: System 2 power loss."
+ ::= { evHVACStatusBardASSystem2 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.2.1
+
+evHVACStatusBardASSystem2Lockout OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: System 2 ref. lockout."
+ ::= { evHVACStatusBardASSystem2 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.2.2
+
+evHVACStatusBardASFire OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: Fire / smoke."
+ ::= { evHVACStatusBardAlarmStatus 3 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.3
+
+evHVACStatusBardASTempLowAlarm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: Low temperature."
+ ::= { evHVACStatusBardASTemp 1 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.4.1
+
+evHVACStatusBardASTempHighAlarm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: High temperature."
+ ::= { evHVACStatusBardASTemp 2 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.4.2
+
+evHVACStatusBardASTempVHighAlarm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: Very high temperature."
+ ::= { evHVACStatusBardASTemp 3 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.4.3
+
+evHVACStatusBardASFailure OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bard HVAC Alarm Status: Controller failure."
+ ::= { evHVACStatusBardAlarmStatus 5 }
+ --1.3.6.1.4.1.3052.10.1.11.2.10.5
+
+evHVACStatusBardConnState OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Connectivity state: 1 means unit has good connectivity to the
+ Bard HVAC controller, 0 otherwise."
+ ::= { evHVACStatusBard 11 }
+ --1.3.6.1.4.1.3052.10.1.11.2.11
+
+--***************************************************************************************
+--Asentria HVAC Status Section 1.11.3
+--***************************************************************************************
+
+evHVACStatusAsentriaSequenceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HVACStatusAsentriaSequence
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC sequence status table"
+ ::= { evHVACStatusAsentria 1 }
+ --1.3.6.1.4.1.3052.10.1.11.3.1
+
+evHVACStatusAsentriaSequenceEntry OBJECT-TYPE
+ SYNTAX HVACStatusAsentriaSequence
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC sequence status table entry"
+ INDEX { evHVACStatusAsentriaSequenceIndex }
+ ::= { evHVACStatusAsentriaSequenceTable 1 }
+ --1.3.6.1.4.1.3052.10.1.11.3.1.1
+
+evHVACStatusAsentriaSequenceIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Asentria HVAC sequence"
+ ::= { evHVACStatusAsentriaSequenceEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.11.3.1.1.1
+
+evHVACStatusAsentriaSeqVentTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC sequence time spent venting"
+ ::= { evHVACStatusAsentriaSequenceEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.11.3.1.1.2
+
+evHVACStatusAsentriaSeqCoolTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC sequence time spent cooling"
+ ::= { evHVACStatusAsentriaSequenceEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.11.3.1.1.3
+
+evHVACStatusAsentriaSeqHeatTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC sequence time spent heating"
+ ::= { evHVACStatusAsentriaSequenceEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.11.3.1.1.4
+
+evHVACStatusAsentriaSeqIdleTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC sequence time spent idling"
+ ::= { evHVACStatusAsentriaSequenceEntry 5 }
+ --1.3.6.1.4.1.3052.10.1.11.3.1.1.5
+
+evHVACStatusAsentriaUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HVACStatusAsentriaUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit status table"
+ ::= { evHVACStatusAsentria 2 }
+ --1.3.6.1.4.1.3052.10.1.11.3.2
+
+evHVACStatusAsentriaUnitEntry OBJECT-TYPE
+ SYNTAX HVACStatusAsentriaUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit status table entry"
+ INDEX { evHVACStatusAsentriaUnitIndex }
+ ::= { evHVACStatusAsentriaUnitTable 1 }
+ --1.3.6.1.4.1.3052.10.1.11.3.2.1
+
+evHVACStatusAsentriaUnitIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Asentria HVAC unit"
+ ::= { evHVACStatusAsentriaUnitEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.11.3.2.1.1
+
+evHVACStatusAsentriaUnitState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit status"
+ ::= { evHVACStatusAsentriaUnitEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.11.3.2.1.2
+
+evHVACStatusAsentriaUnitVentTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit time spent venting"
+ ::= { evHVACStatusAsentriaUnitEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.11.3.2.1.3
+
+evHVACStatusAsentriaUnitCoolTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit time spent cooling"
+ ::= { evHVACStatusAsentriaUnitEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.11.3.2.1.4
+
+evHVACStatusAsentriaUnitHeatTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit time spent heating"
+ ::= { evHVACStatusAsentriaUnitEntry 5 }
+ --1.3.6.1.4.1.3052.10.1.11.3.2.1.5
+
+evHVACStatusAsentriaUnitIdleTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit time spent idling"
+ ::= { evHVACStatusAsentriaUnitEntry 6 }
+ --1.3.6.1.4.1.3052.10.1.11.3.2.1.6
+
+evHVACStatusAsentriaBackupEvent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC backup event"
+ ::= { evHVACStatusAsentria 3 }
+ --1.3.6.1.4.1.3052.10.1.11.3.3
+
+evHVACStatusAsentriaFireEvent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC smoke/fire event"
+ ::= { evHVACStatusAsentria 4 }
+ --1.3.6.1.4.1.3052.10.1.11.3.4
+
+evHVACStatusAsentriaTempOut OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature outside"
+ ::= { evHVACStatusAsentriaTemp 1 }
+ --1.3.6.1.4.1.3052.10.1.11.3.5.1
+
+evHVACStatusAsentriaTempIn OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature inside"
+ ::= { evHVACStatusAsentriaTemp 2 }
+ --1.3.6.1.4.1.3052.10.1.11.3.5.2
+
+evHVACStatusAsentriaHumidOut OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity outside"
+ ::= { evHVACStatusAsentriaHumid 1 }
+ --1.3.6.1.4.1.3052.10.1.11.3.6.1
+
+evHVACStatusAsentriaHumidIn OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity inside"
+ ::= { evHVACStatusAsentriaHumid 2 }
+ --1.3.6.1.4.1.3052.10.1.11.3.6.2
+
+
+--***************************************************************************************
+--Airsys HVAC Status Section 1.11.4
+--***************************************************************************************
+
+evHVACStatusAirsysAlarmUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HVACStatusAirsysAlarmUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit alarm status table"
+ ::= { evHVACStatusAirsysAlarm 1 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1
+
+evHVACStatusAirsysAlarmUnitEntry OBJECT-TYPE
+ SYNTAX HVACStatusAirsysAlarmUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit alarm status table entry"
+ INDEX { evHVACStatusAirsysAlarmUnitIndex }
+ ::= { evHVACStatusAirsysAlarmUnitTable 1 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1.1
+
+evHVACStatusAirsysAlarmUnitIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Airsys HVAC unit alarms"
+ ::= { evHVACStatusAirsysAlarmUnitEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.1
+
+evHVACStatusAirsysAlarmUnitLowPress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit low pressure event"
+ ::= { evHVACStatusAirsysAlarmUnitEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.2
+
+evHVACStatusAirsysAlarmUnitHighPress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit high pressure event"
+ ::= { evHVACStatusAirsysAlarmUnitEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.3
+
+evHVACStatusAirsysAlarmUnitEvapFan OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit AC power/evaporator fan overload event"
+ ::= { evHVACStatusAirsysAlarmUnitEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.4
+
+evHVACStatusAirsysAlarmUnitDirty OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit dirty filter event"
+ ::= { evHVACStatusAirsysAlarmUnitEntry 5 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.5
+
+evHVACStatusAirsysAlarmUnitDamper OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit damper event"
+ ::= { evHVACStatusAirsysAlarmUnitEntry 6 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.6
+
+evHVACStatusAirsysAlarmUnitSupProbe OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit supply probe broken event"
+ ::= { evHVACStatusAirsysAlarmUnitEntry 7 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.1.1.7
+
+evHVACStatusAirsysAlarmSmokeFire OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC smoke/fire event"
+ ::= { evHVACStatusAirsysAlarm 2 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.2
+
+evHVACStatusAirsysAlarmLowRoomTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC low temperature event"
+ ::= { evHVACStatusAirsysAlarm 3 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.3
+
+evHVACStatusAirsysAlarmHighRoomTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC high temperature event"
+ ::= { evHVACStatusAirsysAlarm 4 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.4
+
+evHVACStatusAirsysAlarmPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC power failure event"
+ ::= { evHVACStatusAirsysAlarm 5 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.5
+
+evHVACStatusAirsysAlarmpLAN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC pLAN event"
+ ::= { evHVACStatusAirsysAlarm 6 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.6
+
+evHVACStatusAirsysAlarmClock OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC clock card event"
+ ::= { evHVACStatusAirsysAlarm 7 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.7
+
+evHVACStatusAirsysAlarmHumidProbe OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC humidity probe broken event"
+ ::= { evHVACStatusAirsysAlarm 8 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.8
+
+evHVACStatusAirsysAlarmOutProbe OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC outdoor probe broken event"
+ ::= { evHVACStatusAirsysAlarm 9 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.9
+
+evHVACStatusAirsysAlarmBothCompress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC both compressors running event"
+ ::= { evHVACStatusAirsysAlarm 10 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.10
+
+evHVACStatusAirsysAlarmGenerator OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC generator running event"
+ ::= { evHVACStatusAirsysAlarm 11 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.11
+
+evHVACStatusAirsysAlarmConnection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC controller connection event"
+ ::= { evHVACStatusAirsysAlarm 12 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.12
+
+evHVACStatusAirsysAlarmInProbe1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC indoor probe broken event"
+ ::= { evHVACStatusAirsysAlarm 13 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.13
+
+evHVACStatusAirsysAlarmInProbe2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC backup indoor probe broken event"
+ ::= { evHVACStatusAirsysAlarm 14 }
+ --1.3.6.1.4.1.3052.10.1.11.4.1.14
+
+evHVACStatusAirsysTempOut OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC outdoor temperature"
+ ::= { evHVACStatusAirsys 2 }
+ --1.3.6.1.4.1.3052.10.1.11.4.2
+
+evHVACStatusAirsysTempIn OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC indoor temperature"
+ ::= { evHVACStatusAirsys 3 }
+ --1.3.6.1.4.1.3052.10.1.11.4.3
+
+evHVACStatusAirsysTempInBackup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC backup indoor temperature"
+ ::= { evHVACStatusAirsys 4 }
+ --1.3.6.1.4.1.3052.10.1.11.4.4
+
+evHVACStatusAirsysHumidIn OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC indoor humidity"
+ ::= { evHVACStatusAirsys 5 }
+ --1.3.6.1.4.1.3052.10.1.11.4.5
+
+evHVACStatusAirsysUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HVACStatusAirsysUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit alarm status table"
+ ::= { evHVACStatusAirsys 6 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6
+
+evHVACStatusAirsysUnitEntry OBJECT-TYPE
+ SYNTAX HVACStatusAirsysUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit alarm status table entry"
+ INDEX { evHVACStatusAirsysUnitIndex }
+ ::= { evHVACStatusAirsysUnitTable 1 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1
+
+evHVACStatusAirsysUnitIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Airsys HVAC unit"
+ ::= { evHVACStatusAirsysUnitEntry 1 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.1
+
+evHVACStatusAirsysUnitTempSupply OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit supply temperature"
+ ::= { evHVACStatusAirsysUnitEntry 2 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.2
+
+evHVACStatusAirsysUnitFanspeed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit fan speed"
+ ::= { evHVACStatusAirsysUnitEntry 3 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.3
+
+evHVACStatusAirsysUnitFreeOpening OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit free cooling vent opening percentage"
+ ::= { evHVACStatusAirsysUnitEntry 4 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.4
+
+evHVACStatusAirsysUnitStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit running status"
+ ::= { evHVACStatusAirsysUnitEntry 5 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.5
+
+evHVACStatusAirsysUnitLocked OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit locked status"
+ ::= { evHVACStatusAirsysUnitEntry 6 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.6
+
+evHVACStatusAirsysUnitCompressor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit state of compressor"
+ ::= { evHVACStatusAirsysUnitEntry 7 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.7
+
+evHVACStatusAirsysUnitHeater OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit state of heater"
+ ::= { evHVACStatusAirsysUnitEntry 8 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.8
+
+evHVACStatusAirsysURuntimeSupplyFan OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit run time of supply fan in hours"
+ ::= { evHVACStatusAirsysUnitEntry 9 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.9
+
+evHVACStatusAirsysURuntimeCompressor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit run time of compressor in hours"
+ ::= { evHVACStatusAirsysUnitEntry 10 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.10
+
+evHVACStatusAirsysURuntimeHeat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit run time of heating in hours"
+ ::= { evHVACStatusAirsysUnitEntry 11 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.11
+
+evHVACStatusAirsysURuntimeFreeCooling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit run time of free cooling in hours"
+ ::= { evHVACStatusAirsysUnitEntry 12 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.12
+
+evHVACStatusAirsysUCountSupplyFan OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit number of times supply fan has started"
+ ::= { evHVACStatusAirsysUnitEntry 13 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.13
+
+evHVACStatusAirsysUCountCompressor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit number of times compressor has started"
+ ::= { evHVACStatusAirsysUnitEntry 14 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.14
+
+evHVACStatusAirsysUCountHeat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit number of times heating has started"
+ ::= { evHVACStatusAirsysUnitEntry 15 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.15
+
+evHVACStatusAirsysUCountFreeCooling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit number of times free cooling has started"
+ ::= { evHVACStatusAirsysUnitEntry 16 }
+ --1.3.6.1.4.1.3052.10.1.11.4.6.1.16
+
+evHVACStatusAirsysDay OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC controller day"
+ ::= { evHVACStatusAirsys 7 }
+ --1.3.6.1.4.1.3052.10.1.11.4.7
+
+evHVACStatusAirsysDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC controller date"
+ ::= { evHVACStatusAirsys 8 }
+ --1.3.6.1.4.1.3052.10.1.11.4.8
+
+evHVACStatusAirsysTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC controller time"
+ ::= { evHVACStatusAirsys 9 }
+ --1.3.6.1.4.1.3052.10.1.11.4.9
+
+evHVACStatusAirsysVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC controller software version"
+ ::= { evHVACStatusAirsys 10 }
+ --1.3.6.1.4.1.3052.10.1.11.4.10
+
+--***************************************************************************************
+--Battery Backup Status Section 1.12
+--***************************************************************************************
+liBattPercentCharge OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Lithium Battery State Charge in Percent (0% to 100%)"
+ ::= { liBattStatus 1 }
+ --1.3.6.1.4.1.3052.10.1.12.1.1
+
+liBattRunning OBJECT-TYPE
+ SYNTAX Integer32 (0..1)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Is the unit running on battery backup: (TRUE/FALSE) or (1/0)"
+ ::= { liBattStatus 2 }
+ --1.3.6.1.4.1.3052.10.1.12.1.2
+
+--***************************************************************************************
+--EventSensor Basics Section 2.1
+--***************************************************************************************
+
+esNumberEventSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of EventSensors recognized by the unit,
+ including the internal EventSensor.
+ Range: 1-17"
+ ::= { eventSensorBasics 1 }
+ --1.3.6.1.4.1.3052.10.2.1.1
+
+esTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESExist
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of what EventSensors are attached to the unit,
+ including the internal EventSensor"
+ ::= { eventSensorBasics 2 }
+ --1.3.6.1.4.1.3052.10.2.1.2
+
+esEntry OBJECT-TYPE
+ SYNTAX ESExist
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for EventSensor table"
+ INDEX { esIndex }
+ ::= { esTable 1 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1
+
+esIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This number refers to an EventSensor; it has the
+ same meaning as the esIndexES object (see above),
+ except that this object is used only within the
+ esTable branch.
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndex=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.1
+
+esName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the EventSensor"
+ ::= { esEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.2
+
+esID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The factory-assigned ID of the EventSensor"
+ ::= { esEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.3
+
+esNumberTempSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of temperature sensors on the EventSensor"
+ ::= { esEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.4
+
+esTempReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how temperature values should
+ be interpreted."
+ ::= { esEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.5
+
+esNumberCCs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of contact closures on the EventSensor."
+ ::= { esEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.6
+
+esCCReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how CC values should be interpreted."
+ ::= { esEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.7
+
+esNumberHumidSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of humidity sensors on the EventSensor."
+ ::= { esEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.8
+
+esHumidReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how humidity sensor values should be
+ interpreted."
+ ::= { esEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.9
+
+esNumberNoiseSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of noise sensors on the EventSensor."
+ ::= { esEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.10
+
+esNoiseReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how noise sensor values should be
+ interpreted."
+ ::= { esEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.11
+
+esNumberAirflowSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of airflow sensors on the EventSensor."
+ ::= { esEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.12
+
+esAirflowReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how airflow sensor values should be
+ interpreted."
+ ::= { esEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.13
+
+esNumberAnalog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of analog inputs on the EventSensor."
+ ::= { esEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.14
+
+esAnalogReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how analog input values should be
+ interpreted."
+ ::= { esEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.15
+
+esNumberOutputs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs (relay or power) on the EventSensor"
+ ::= { esEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.16
+
+esOutputReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how output values should be interpreted."
+ ::= { esEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.17
+
+esTempCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`value`scale`eventState`eventColorCode"
+ ::= { esEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.18
+
+esCCCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8"
+ ::= { esEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.19
+
+esCCCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16"
+ ::= { esEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.20
+
+esCCCombinedStatusBlock3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24"
+ ::= { esEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.21
+
+esCCCombinedStatusBlock4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32"
+ ::= { esEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.22
+
+esCCCombinedStatusBlock5 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40"
+ ::= { esEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.23
+
+esCCCombinedStatusBlock6 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48"
+ ::= { esEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.24
+
+esCCCombinedStatusBlock7 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56"
+ ::= { esEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.25
+
+esCCCombinedStatusBlock8 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64"
+ ::= { esEntry 26 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.26
+
+esHumidCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`value`eventState`eventColorCode"
+ ::= { esEntry 27 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.27
+
+esAnalogCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~..."
+ ::= { esEntry 28 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.28
+
+esAnalogCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name9`value9`units9`eventState9`eventColorCode9~..."
+ ::= { esEntry 29 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.29
+
+esAnalogCombinedStatusBlock3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 30 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.31
+
+esAnalogCombinedStatusBlock4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 31 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.31
+
+esAnalogCombinedStatusBlock5 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 32 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.32
+
+esAnalogCombinedStatusBlock6 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 33 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.33
+
+esOutputCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 34 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.34
+
+esOutputCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz"
+ ::= { esEntry 35 }
+ --1.3.6.1.4.1.3052.10.2.1.2.1.35
+
+esNewSensors OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "String representing the number of new (attached but unconfigured) EventSensors"
+ ::= { eventSensorBasics 3 }
+ --1.3.6.1.4.1.3052.10.2.1.3
+
+
+--***************************************************************************************
+--EventSensor Point Config Section 2.2
+--***************************************************************************************
+
+
+
+esPointConfigTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigTemp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of temperature
+ sensor points. A point is a particular sensor on an
+ EventSensor. The 3 point attributes organizes in this table
+ are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number (always 1 for temp sensors)
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by periods.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ emperature point config table ; namely, which EventSensor,
+ and which sensor (a.k.a. point) (always 1 for temperature
+ sensors).
+ "
+ ::= { eventSensorPointConfig 1 }
+ --1.3.6.1.4.1.3052.10.2.2.1
+
+esPointConfigTempEntry OBJECT-TYPE
+ SYNTAX ESPointConfigTemp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config temperature table"
+ INDEX { espcTempIndexES, espcTempIndexPoint }
+ ::= { esPointConfigTempTable 1 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1
+
+espcTempIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config temperature table; namely, which EventSensor,
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndexES=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esPointConfigTempEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.1
+
+espcTempIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcTempIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of temperature point configuration."
+ ::= { esPointConfigTempEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.2
+
+espcTempEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this temperature sensor"
+ ::= { esPointConfigTempEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.3
+
+espcTempScale OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Scale (C/F) for this temperature sensor"
+ ::= { esPointConfigTempEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.4
+
+espcTempDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this temperature sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.5
+
+espcTempVHighTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.6
+
+espcTempVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event actions for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.7
+
+espcTempVHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event trap number for this
+ temperature sensor"
+ ::= { esPointConfigTempEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.8
+
+espcTempVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event class for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.9
+
+espcTempHighTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.10
+
+espcTempHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.11
+
+espcTempHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.12
+
+espcTempHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.13
+
+espcTempNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.14
+
+espcTempNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.15
+
+espcTempNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.16
+
+espcTempLowTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event threshold for this temperature sensor
+ (in floating-point format)"
+ ::= { esPointConfigTempEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.17
+
+espcTempLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.18
+
+espcTempLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.19
+
+espcTempLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.20
+
+espcTempVLowTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.21
+
+espcTempVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event actions for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.22
+
+espcTempVLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.23
+
+espcTempVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.24
+
+espcTempGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this temperature sensor group"
+ ::= { esPointConfigTempEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.2.1.1.25
+
+esPointConfigCCTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigCC
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of contact closure
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor within the context of this
+ contact closure point config table ; namely, which
+ EventSensor and which sensor.
+ "
+ ::= { eventSensorPointConfig 2 }
+ --1.3.6.1.4.1.3052.10.2.2.2
+
+esPointConfigCCEntry OBJECT-TYPE
+ SYNTAX ESPointConfigCC
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config contact closure table"
+ INDEX { espcCCIndexES, espcCCIndexPoint }
+ ::= { esPointConfigCCTable 1 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1
+
+espcCCIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigCCEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.1
+
+espcCCIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcCCIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigCCEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.2
+
+espcCCEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable for this contact closure"
+ ::= { esPointConfigCCEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.3
+
+espcCCName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this contact closure"
+ ::= { esPointConfigCCEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.4
+
+espcCCEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event state for this contact closure"
+ ::= { esPointConfigCCEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.5
+
+espcCCThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event threshold (seconds) for this contact closure"
+ ::= { esPointConfigCCEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.6
+
+espcCCEventActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event actions for this contact closure"
+ ::= { esPointConfigCCEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.7
+
+espcCCEventTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event trap number for this contact closure"
+ ::= { esPointConfigCCEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.8
+
+espcCCEventClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event class for this contact closure"
+ ::= { esPointConfigCCEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.9
+
+espcCCNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this contact closure"
+ ::= { esPointConfigCCEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.10
+
+espcCCNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this contact closure"
+ ::= { esPointConfigCCEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.11
+
+espcCCNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this contact closure"
+ ::= { esPointConfigCCEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.12
+
+espcCCAlarmAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event alias for this contact closure"
+ ::= { esPointConfigCCEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.13
+
+espcCCNormalAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal alias for this contact closure"
+ ::= { esPointConfigCCEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.14
+
+espcCCNormalThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event threshold (seconds) for this contact closure to return to normal"
+ ::= { esPointConfigCCEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.15
+
+espcCCOverrideGlobalReminder OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Override global reminder interval (evReminderInterval) for this CC."
+ ::= { esPointConfigCCEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.16
+
+espcCCReminderInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Individual reminder interval for this CC, applicable when the global
+ reminder is overriden."
+ ::= { esPointConfigCCEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.17
+
+espcCCGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this contact closure group"
+ ::= { esPointConfigCCEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.2.2.1.18
+
+esPointConfigHumidTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigHumid
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of humidity points.
+ A point is a particular sensor on an EventSensor. The 3
+ point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number (always 1 for humidity sensors)
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor within the context of this
+ humidity point config table ; namely, which EventSensor and
+ which sensor.
+ "
+ ::= { eventSensorPointConfig 3 }
+ --1.3.6.1.4.1.3052.10.2.2.3
+
+esPointConfigHumidEntry OBJECT-TYPE
+ SYNTAX ESPointConfigHumid
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config humidity table"
+ INDEX { espcHumidIndexES, espcHumidIndexPoint }
+ ::= { esPointConfigHumidTable 1 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1
+
+espcHumidIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigHumidEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.1
+
+espcHumidIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcHumidIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigHumidEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.2
+
+espcHumidEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable for this humidity sensor"
+ ::= { esPointConfigHumidEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.3
+
+espcHumidDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this humidity sensor"
+ ::= { esPointConfigHumidEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.4
+
+espcHumidVHighHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.5
+
+espcHumidVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.6
+
+espcHumidVHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.7
+
+espcHumidVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.8
+
+espcHumidHighHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.9
+
+espcHumidHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.10
+
+espcHumidHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.11
+
+espcHumidHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.12
+
+espcHumidNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.13
+
+espcHumidNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.14
+
+espcHumidNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.15
+
+espcHumidLowHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.16
+
+espcHumidLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.17
+
+espcHumidLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.18
+
+espcHumidLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.19
+
+espcHumidVLowHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.20
+
+espcHumidVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.21
+
+espcHumidVLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.22
+
+espcHumidVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.23
+
+espcHumidGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this humidity sensor group"
+ ::= { esPointConfigHumidEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.2.3.1.24
+
+esPointConfigAITable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigAnalogInput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of analog input
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ analog input point config table ; namely, which EventSensor
+ and which sensor.
+ "
+ ::= { eventSensorPointConfig 5 }
+ --1.3.6.1.4.1.3052.10.2.2.5
+
+esPointConfigAIEntry OBJECT-TYPE
+ SYNTAX ESPointConfigAnalogInput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config analog input table"
+ INDEX { espcHumidIndexES, espcHumidIndexPoint }
+ ::= { esPointConfigAITable 1 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1
+
+espcAIIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigAIEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.1
+
+espcAIIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcAIIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigAIEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.2
+
+espcAIEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for this analog input sensor"
+ ::= { esPointConfigAIEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.3
+
+espcAIDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this analog input sensor"
+ ::= { esPointConfigAIEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.5
+
+espcAIVhighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold (decivolts or tenths of
+ milliamps) for this analog input sensor"
+ ::= { esPointConfigAIEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.6
+
+espcAIVhighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.7
+
+espcAIVhighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.8
+
+espcAIVhighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.9
+
+espcAIHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold (decivolts or tenths of milliamps) for
+ this analog input sensor"
+ ::= { esPointConfigAIEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.10
+
+espcAIHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.11
+
+espcAIHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.12
+
+espcAIHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.13
+
+espcAINormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.14
+
+espcAINormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.15
+
+espcAINormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this analog input sensor"
+ ::= { esPointConfigAIEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.16
+
+espcAILowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold (decivolts or tenths of milliamps) for
+ this analog input sensor"
+ ::= { esPointConfigAIEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.17
+
+espcAILowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.18
+
+espcAILowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.19
+
+espcAILowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.20
+
+espcAIVlowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold (decivolts or tenths of milliamps)
+ for this analog input sensor"
+ ::= { esPointConfigAIEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.21
+
+espcAIVlowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.22
+
+espcAIVlowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.23
+
+espcAIVlowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.24
+
+espcAIConvUnitName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Converstion unit name for this analog input sensor"
+ ::= { esPointConfigAIEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.25
+
+espcAIConvHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion high value for this analog input sensor"
+ ::= { esPointConfigAIEntry 26 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.26
+
+espcAIConvHighUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion high unit value for this analog input sensor"
+ ::= { esPointConfigAIEntry 27 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.27
+
+espcAIConvLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion low value for this analog input sensor"
+ ::= { esPointConfigAIEntry 29 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.29
+
+espcAIConvLowUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion unit low unit value for this analog input sensor"
+ ::= { esPointConfigAIEntry 30 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.30
+
+espcAIDisplayFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input display format"
+ ::= { esPointConfigAIEntry 32 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.32
+
+espcAIGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this Analog input group"
+ ::= { esPointConfigAIEntry 33 }
+ --1.3.6.1.4.1.3052.10.2.2.5.1.33
+
+esPointConfigOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigOutput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes configuration items for output
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organized in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ output config table ; namely, which EventSensor
+ and which sensor.
+ "
+ ::= { eventSensorPointConfig 6 }
+ --1.3.6.1.4.1.3052.10.2.2.6
+
+esPointConfigOutputEntry OBJECT-TYPE
+ SYNTAX ESPointConfigOutput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config output table"
+ INDEX { espcOutputIndexES, espcOutputIndexPoint }
+ ::= { esPointConfigOutputTable 1 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1
+
+espcOutputIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigOutputEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.1
+
+espcOutputIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcOutputIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of output point configuration."
+ ::= { esPointConfigOutputEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.2
+
+espcOutputEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables the output event for this output. This has no effect
+ on whether the relay changes state, only on whether a state change
+ triggers an event."
+ ::= { esPointConfigOutputEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.3
+
+espcOutputActiveState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which state is considered the active state: energized/de-energized."
+ ::= { esPointConfigOutputEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.4
+
+espcOutputType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output type: RELAY, POWER, SSR, TTL."
+ ::= { esPointConfigOutputEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.5
+
+espcOutputAliasValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output alias corresponding to its event state."
+ ::= { esPointConfigOutputEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.6
+
+espcOutputAliasColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output color corresponding to its event state."
+ ::= { esPointConfigOutputEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.7
+
+espcOutputActiveAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alias for the output active state."
+ ::= { esPointConfigOutputEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.10
+
+espcOutputActiveColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output color (as rendered in the web UI, in RGB hex format) corresponding
+ to the output active state."
+ ::= { esPointConfigOutputEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.11
+
+espcOutputActiveActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output active event."
+ ::= { esPointConfigOutputEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.12
+
+espcOutputActiveTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (150..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output active event."
+ ::= { esPointConfigOutputEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.13
+
+espcOutputActiveClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the output active event."
+ ::= { esPointConfigOutputEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.14
+
+espcOutputInactiveAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alias for the output inactive state."
+ ::= { esPointConfigOutputEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.20
+
+espcOutputInactiveColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output color (as rendered in the web UI, in RGB hex format) corresponding
+ to the output inactive state."
+ ::= { esPointConfigOutputEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.21
+
+espcOutputInactiveActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output inactive event."
+ ::= { esPointConfigOutputEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.22
+
+espcOutputInactiveTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (150..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output inactive event."
+ ::= { esPointConfigOutputEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.23
+
+espcOutputInactiveClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the output inactive event."
+ ::= { esPointConfigOutputEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.24
+
+espcOutputGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this Ouput Group"
+ ::= { esPointConfigOutputEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.2.6.1.25
+
+--***************************************************************************************
+--Serial Port Section 2.3
+--***************************************************************************************
+
+numberPorts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of RS-232 ports found.
+ Range: 2 or 4"
+ ::= { serialPorts 1 }
+ --1.3.6.1.4.1.3052.10.2.3.1
+
+portConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port config table"
+ ::= { serialPorts 2 }
+ --1.3.6.1.4.1.3052.10.2.3.2
+
+portConfigEntry OBJECT-TYPE
+ SYNTAX PortConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port config entry"
+ INDEX { portConfigIndex }
+ ::= { portConfigTable 1 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1
+
+portConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for ports"
+ ::= { portConfigEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.1
+
+portConfigBaud OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Baud rate, 19200, 9600, etc."
+ ::= { portConfigEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.2
+
+portConfigDataFormat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Value representing word length, parity, and
+ stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2"
+ ::= { portConfigEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.3
+
+portConfigStripPtOutputLfs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Strip passthrough LFs sent to device on this port:
+ 1=yes, 0=no."
+ ::= { portConfigEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.4
+
+portConfigStripPtInputLfs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Strip passthrough LFs received from device on this
+ port: 1=yes, 0=no."
+ ::= { portConfigEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.5
+
+portConfigMaskEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1=Use the character mask on this port. 0=Do
+ not use the mask. When the mask is enabled,
+ the following ASCII characters are ignored
+ on the port:
+ 0, 1, 4-9, 11, 12, 14-31, 128-255.
+ When the mask is disabled, all characters are
+ accepted on the port."
+ ::= { portConfigEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.7
+
+portConfigDAEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1=Enable the Data Alarm Evaluator for data
+ on this port. 0=Do not evaluate data on this
+ port."
+ ::= { portConfigEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.8
+
+portConfigStoreAlarmsDPT OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: store alarms received during passthrough"
+ ::= { portConfigEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.9
+
+portConfigRecordTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout after last unterminated data received upon
+ which data collected so far is stored as a record."
+ ::= { portConfigEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.10
+
+portConfigDataType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How the port interprets incoming data: ASCII/BINARY"
+ ::= { portConfigEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.11
+
+portConfigEtxToCRLF OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF whether the port translates incoming ETX to CRLF"
+ ::= { portConfigEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.12
+
+portConfigMLREnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Whether Multiline Records are collected on this port."
+ ::= { portConfigEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.13
+
+portConfigMLRStartField1Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR start field 1"
+ ::= { portConfigEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.14
+
+portConfigMLRStartField1Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR start field 1"
+ ::= { portConfigEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.15
+
+portConfigMLRStartField2Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR start field 2"
+ ::= { portConfigEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.16
+
+portConfigMLRStartField2Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR start field 2"
+ ::= { portConfigEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.17
+
+portConfigMLRNumLinesBefore OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of lines before the starting line which should
+ be included in the MLR"
+ ::= { portConfigEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.18
+
+portConfigMLREndDetection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How the MLR parser determines what ends an MLR: by FORMULA,
+ number of lines received so far (COUNT), or number of blank
+ lines received so far (BLANKS)"
+ ::= { portConfigEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.19
+
+portConfigMLRLineCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of lines in the MLR (used by the end detection mode)"
+ ::= { portConfigEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.20
+
+portConfigMLREndField1Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR end field 1"
+ ::= { portConfigEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.21
+
+portConfigMLREndField1Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR end field 1"
+ ::= { portConfigEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.22
+
+portConfigMLREndField2Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR end field 2"
+ ::= { portConfigEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.23
+
+portConfigMLREndField2Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR end field 2"
+ ::= { portConfigEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.24
+
+portConfigMLRUseComplexRules OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF MLR parser uses complex rules (field possitions/
+ formulas, etc.)"
+ ::= { portConfigEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.25
+
+portConfigBufferPT OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF records received during passthrough mode are
+ buffered/stored in the database"
+ ::= { portConfigEntry 26 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.26
+
+portConfigId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The text identifer for the port"
+ ::= { portConfigEntry 27 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.27
+
+portConfigMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Mode of the serial port."
+ ::= { portConfigEntry 28 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.28
+
+portConfigHsk OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Handshaking mode of the serial port."
+ ::= { portConfigEntry 29 }
+ --1.3.6.1.4.1.3052.10.2.3.2.1.29
+
+
+--***************************************************************************************
+--Network Section 2.4
+--***************************************************************************************
+
+eth1Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of the Ethernet1 interface: STATIC,DHCP,VLAN"
+ ::= { ethernet1 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.1
+
+eth1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 IP address"
+ ::= { ethernet1 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.2
+
+eth1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 subnet mask"
+ ::= { ethernet1 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.3
+
+eth1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 router"
+ ::= { ethernet1 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.4
+
+-- Ethernet1 VLAN1
+
+eth1VLAN1ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 ID"
+ ::= { eth1VLAN1 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.1
+
+eth1VLAN1Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 priority"
+ ::= { eth1VLAN1 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.2
+
+eth1VLAN1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 IP address"
+ ::= { eth1VLAN1 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.3
+
+eth1VLAN1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 subnet mask"
+ ::= { eth1VLAN1 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.4
+
+eth1VLAN1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 router"
+ ::= { eth1VLAN1 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.1.5
+
+-- Ethernet1 VLAN2
+
+eth1VLAN2ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 ID"
+ ::= { eth1VLAN2 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.1
+
+eth1VLAN2Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 priority"
+ ::= { eth1VLAN2 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.2
+
+eth1VLAN2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 IP address"
+ ::= { eth1VLAN2 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.3
+
+eth1VLAN2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 subnet mask"
+ ::= { eth1VLAN2 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.4
+
+eth1VLAN2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 router"
+ ::= { eth1VLAN2 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.2.5
+
+-- Ethernet1 VLAN3
+
+eth1VLAN3ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 ID"
+ ::= { eth1VLAN3 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.1
+
+eth1VLAN3Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 priority"
+ ::= { eth1VLAN3 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.2
+
+eth1VLAN3Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 IP address"
+ ::= { eth1VLAN3 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.3
+
+eth1VLAN3SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 subnet mask"
+ ::= { eth1VLAN3 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.4
+
+eth1VLAN3Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 router"
+ ::= { eth1VLAN3 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.3.5
+
+-- Ethernet1 VLAN4
+
+eth1VLAN4ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 ID"
+ ::= { eth1VLAN4 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.1
+
+eth1VLAN4Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 priority"
+ ::= { eth1VLAN4 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.2
+
+eth1VLAN4Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 IP address"
+ ::= { eth1VLAN4 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.3
+
+eth1VLAN4SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 subnet mask"
+ ::= { eth1VLAN4 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.4
+
+eth1VLAN4Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 router"
+ ::= { eth1VLAN4 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.4.5
+
+-- Ethernet1 VLAN5
+
+eth1VLAN5ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 ID"
+ ::= { eth1VLAN5 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.1
+
+eth1VLAN5Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 priority"
+ ::= { eth1VLAN5 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.2
+
+eth1VLAN5Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 IP address"
+ ::= { eth1VLAN5 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.3
+
+eth1VLAN5SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 subnet mask"
+ ::= { eth1VLAN5 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.4
+
+eth1VLAN5Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 router"
+ ::= { eth1VLAN5 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.5.5
+
+-- Ethernet1 VLAN6
+
+eth1VLAN6ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 ID"
+ ::= { eth1VLAN6 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.1
+
+eth1VLAN6Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 priority"
+ ::= { eth1VLAN6 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.2
+
+eth1VLAN6Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 IP address"
+ ::= { eth1VLAN6 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.3
+
+eth1VLAN6SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 subnet mask"
+ ::= { eth1VLAN6 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.4
+
+eth1VLAN6Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 router"
+ ::= { eth1VLAN6 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.5.6.5
+
+eth1MAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 MAC"
+ ::= { ethernet1 6 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.6
+
+eth1IPv6Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls IPv6 operation for this Ethernet interface."
+ ::= { eth1IPv6 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.1
+
+eth1IPv6StaticAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "he static IPv6 address to use for this interface when in
+ operating in STATIC mode."
+ ::= { eth1IPv6Static 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.2.1
+
+eth1IPv6StaticRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 router to engage as the default router when this
+ interface operates in STATIC mode."
+ ::= { eth1IPv6Static 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.2.1
+
+eth1IPv6AutoAddress1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.3.1
+
+eth1IPv6AutoAddress2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.3.2
+
+eth1IPv6AutoAddress3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.3.3
+
+eth1IPv6AutoAddress4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.3.4
+
+eth1IPv6LinkLocalAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link local IPv6 address for this interface. This is
+ present when the IPv6 mode is not OFF."
+ ::= { eth1IPv6 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.1.7.4
+
+
+
+eth2Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of the Ethernet2 interface: STATIC,DHCP,VLAN"
+ ::= { ethernet2 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.1
+
+eth2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 IP address"
+ ::= { ethernet2 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.2
+
+eth2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 subnet mask"
+ ::= { ethernet2 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.3
+
+eth2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 router"
+ ::= { ethernet2 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.4
+
+
+-- Ethernet2 VLAN1
+
+eth2VLAN1ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 ID"
+ ::= { eth2VLAN1 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.1
+
+eth2VLAN1Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 priority"
+ ::= { eth2VLAN1 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.2
+
+eth2VLAN1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 IP address"
+ ::= { eth2VLAN1 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.3
+
+eth2VLAN1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 subnet mask"
+ ::= { eth2VLAN1 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.4
+
+eth2VLAN1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 router"
+ ::= { eth2VLAN1 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.1.5
+
+-- Ethernet2 VLAN2
+
+eth2VLAN2ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 ID"
+ ::= { eth2VLAN2 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.1
+
+eth2VLAN2Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 priority"
+ ::= { eth2VLAN2 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.2
+
+eth2VLAN2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 IP address"
+ ::= { eth2VLAN2 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.3
+
+eth2VLAN2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 subnet mask"
+ ::= { eth2VLAN2 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.4
+
+eth2VLAN2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 router"
+ ::= { eth2VLAN2 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.2.5
+
+-- Ethernet2 VLAN3
+
+eth2VLAN3ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 ID"
+ ::= { eth2VLAN3 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.1
+
+eth2VLAN3Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 priority"
+ ::= { eth2VLAN3 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.2
+
+eth2VLAN3Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 IP address"
+ ::= { eth2VLAN3 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.3
+
+eth2VLAN3SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 subnet mask"
+ ::= { eth2VLAN3 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.4
+
+eth2VLAN3Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 router"
+ ::= { eth2VLAN3 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.3.5
+
+-- Ethernet2 VLAN4
+
+eth2VLAN4ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 ID"
+ ::= { eth2VLAN4 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.1
+
+eth2VLAN4Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 priority"
+ ::= { eth2VLAN4 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.2
+
+eth2VLAN4Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 IP address"
+ ::= { eth2VLAN4 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.3
+
+eth2VLAN4SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 subnet mask"
+ ::= { eth2VLAN4 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.4
+
+eth2VLAN4Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 router"
+ ::= { eth2VLAN4 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.4.5
+
+-- Ethernet2 VLAN5
+
+eth2VLAN5ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 ID"
+ ::= { eth2VLAN5 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.1
+
+eth2VLAN5Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 priority"
+ ::= { eth2VLAN5 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.2
+
+eth2VLAN5Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 IP address"
+ ::= { eth2VLAN5 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.3
+
+eth2VLAN5SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 subnet mask"
+ ::= { eth2VLAN5 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.4
+
+eth2VLAN5Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 router"
+ ::= { eth2VLAN5 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.5.5
+
+-- Ethernet2 VLAN6
+
+eth2VLAN6ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 ID"
+ ::= { eth2VLAN6 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.1
+
+eth2VLAN6Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 priority"
+ ::= { eth2VLAN6 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.2
+
+eth2VLAN6Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 IP address"
+ ::= { eth2VLAN6 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.3
+
+eth2VLAN6SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 subnet mask"
+ ::= { eth2VLAN6 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.4
+
+eth2VLAN6Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 router"
+ ::= { eth2VLAN6 5 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.5.6.5
+
+eth2MAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 MAC"
+ ::= { ethernet2 6 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.6
+
+eth2IPv6Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls IPv6 operation for this Ethernet interface."
+ ::= { eth2IPv6 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.1
+
+eth2IPv6StaticAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "he static IPv6 address to use for this interface when in
+ operating in STATIC mode."
+ ::= { eth2IPv6Static 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.2.1
+
+eth2IPv6StaticRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 router to engage as the default router when this
+ interface operates in STATIC mode."
+ ::= { eth2IPv6Static 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.2.1
+
+eth2IPv6AutoAddress1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 1 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.3.1
+
+eth2IPv6AutoAddress2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 2 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.3.2
+
+eth2IPv6AutoAddress3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 3 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.3.3
+
+eth2IPv6AutoAddress4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.3.4
+
+eth2IPv6LinkLocalAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link local IPv6 address for this interface. This is
+ present when the IPv6 mode is not OFF."
+ ::= { eth2IPv6 4 }
+ --1.3.6.1.4.1.3052.10.2.4.1.1.2.7.4
+
+
+
+defaultRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default router/gateway"
+ ::= { network 2 }
+ --1.3.6.1.4.1.3052.10.2.4.2
+
+-- DNS
+
+dnsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DNSConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DNS server address table"
+ ::= { network 3 }
+ --1.3.6.1.4.1.3052.10.2.4.3
+
+dnsEntry OBJECT-TYPE
+ SYNTAX DNSConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DNS server address entry"
+ INDEX { dnsIndex }
+ ::= { dnsTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.3.1
+
+dnsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for DNS server address"
+ ::= { dnsEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.3.1.1
+
+dnsAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNS server address"
+ ::= { dnsEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.3.1.2
+
+hostname OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hostname of the unit"
+ ::= { network 4 }
+ --1.3.6.1.4.1.3052.10.2.4.4
+
+hostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Static host table"
+ ::= { network 5 }
+ --1.3.6.1.4.1.3052.10.2.4.5
+
+hostEntry OBJECT-TYPE
+ SYNTAX HostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Static host entry"
+ INDEX { hostIndex }
+ ::= { hostTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.5.1
+
+hostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for static host"
+ ::= { hostEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.5.1.1
+
+hostDeclaration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Static host declaration string (i.e. 'address hostname')"
+ ::= { hostEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.5.1.2
+
+-- Network Command Processor
+
+ncpDuplex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "For network command processor: 1=Input characters are echoed; 0=no echo."
+ ::= { network 6 }
+ --1.3.6.1.4.1.3052.10.2.4.6
+
+ncpTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Network command processor inactivity timeout"
+ ::= { network 7 }
+ --1.3.6.1.4.1.3052.10.2.4.7
+
+-- SNMP
+
+snmpAgentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for snmp agent"
+ ::= { snmp 1 }
+ --1.3.6.1.4.1.3052.10.2.4.8.1
+
+snmpNotificationCaptureEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit receives and stores SNMP traps/informs"
+ ::= { snmp 5 }
+ --1.3.6.1.4.1.3052.10.2.4.8.5
+
+snmpNotificationCaptureFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "File to which unit stores received SNMP traps/informs"
+ ::= { snmp 6 }
+ --1.3.6.1.4.1.3052.10.2.4.8.6
+
+snmpNtfnAttempts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum of times the unit attempts to send a notification
+ (trap/inform) in 1 cycle"
+ ::= { snmpNotificationTx 1 }
+ --1.3.6.1.4.1.3052.10.2.4.8.7.1
+
+snmpNtfnTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds between retries of sending a notification"
+ ::= { snmpNotificationTx 2 }
+ --1.3.6.1.4.1.3052.10.2.4.8.7.2
+
+snmpNtfnCycles OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of times the unit attempts a group of attempts to send
+ a notification (a cycle)"
+ ::= { snmpNotificationTx 3 }
+ --1.3.6.1.4.1.3052.10.2.4.8.7.3
+
+snmpNtfnSnooze OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes between cycles"
+ ::= { snmpNotificationTx 4 }
+ --1.3.6.1.4.1.3052.10.2.4.8.7.4
+
+-- SNMP proxy
+
+snmpProxyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SNMPProxyTable
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of SNMP proxy entries"
+ ::= { snmpProxy 1 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8.1
+
+snmpProxyEntry OBJECT-TYPE
+ SYNTAX SNMPProxyTable
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for SNMP proxy table"
+ INDEX { snmpProxyIndex }
+ ::= { snmpProxyTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8.1.1
+
+snmpProxyIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for SNMP proxy table"
+ ::= { snmpProxyEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.1
+
+snmpProxyEgressOIDBranch OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The OID branch to trigger the proxy function. This should cover
+ the device to proxy. If blank then this proxy entry is disabled."
+ ::= { snmpProxyEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.2
+
+snmpProxyIP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of the device to proxy."
+ ::= { snmpProxyEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.3
+
+snmpProxyPort OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The UDP port on which the device to proxy listens."
+ ::= { snmpProxyEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.4
+
+snmpProxyIngressOIDBranch OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The OID branch to be remapped to egress OID branch to trigger the
+ proxy function. If blank then the egress OID branch is proxied
+ without remapping."
+ ::= { snmpProxyEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.5
+
+snmpProxyName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of this proxy entry."
+ ::= { snmpProxyEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.4.8.8.1.1.6
+
+-- SNMP Poll
+
+snmpPMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Mode of poll operation: OFF, POLL ONLY (just make the results
+ available to view), or POLL BUFFER (store the results)."
+ ::= { snmpPoll 1 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.1
+
+snmpPBufferFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CRDB file in which data is stored."
+ ::= { snmpPoll 2 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.2
+
+snmpPBufferAllPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Period (in seconds) that, if non-zero, all results are buffered
+ in the CRDB regardless of the threshold."
+ ::= { snmpPoll 3 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.3
+
+snmpPRequestTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SNMPPollRequestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of SNMP Poll requests."
+ ::= { snmpPoll 4 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4
+
+snmpPRequestEntry OBJECT-TYPE
+ SYNTAX SNMPPollRequestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table pf SNMP Poll requests."
+ INDEX { snmpPRequestIndex }
+ ::= { snmpPRequestTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1
+
+snmpPRequestIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of SNMP Poll requests."
+ ::= { snmpPRequestEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.1
+
+snmpPRequestDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A description for this single telemetry request; no functional effect."
+ ::= { snmpPRequestEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.2
+
+snmpPRequestAgent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP Agent IP address or hostname for this single telemetry request."
+ ::= { snmpPRequestEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.3
+
+snmpPRequestReadcom OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP read community for this single telemetry request."
+ ::= { snmpPRequestEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.4
+
+snmpPRequestOID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP object identifier for this single telemetry request."
+ ::= { snmpPRequestEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.5
+
+snmpPRequestPeriod OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How many seconds between periodic SNMP polls of this
+ single telemetry request."
+ ::= { snmpPRequestEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.6
+
+snmpPRequestID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A textual field that is part of the record containing
+ the telemetry result."
+ ::= { snmpPRequestEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.7
+
+snmpPRequestThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls when new data is stored upon a successful
+ telemetry request."
+ ::= { snmpPRequestEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.8
+
+snmpPRequestResultStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of the last attempt for this telemetry request."
+ ::= { snmpPRequestEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.10
+
+snmpPRequestResultValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The telemetry value if the last request was successful."
+ ::= { snmpPRequestEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.11
+
+snmpPRequestResultTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp of the last telemetry request."
+ ::= { snmpPRequestEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.12
+
+snmpPRequestResultType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the telemetry as reported by the agent."
+ ::= { snmpPRequestEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.4.8.9.4.1.13
+
+
+-- FTP
+
+ftpPushEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable FTP push for REGULAR (protocol: FTP) or SECURE (protocol:
+ SFTP) operation, or disable it (OFF)"
+ ::= { ftpPush 1 }
+ --1.3.6.1.4.1.3052.10.2.4.9.1
+
+ftpPushServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP server to which data should be pushed"
+ ::= { ftpPush 2 }
+ --1.3.6.1.4.1.3052.10.2.4.9.2
+
+ftpPushAccount OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP push account"
+ ::= { ftpPush 5 }
+ --1.3.6.1.4.1.3052.10.2.4.9.5
+
+ftpPushDirectory OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP push directory"
+ ::= { ftpPush 6 }
+ --1.3.6.1.4.1.3052.10.2.4.9.6
+
+ftpPushperiod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes between pushes"
+ ::= { ftpPush 7 }
+ --1.3.6.1.4.1.3052.10.2.4.9.7
+
+ftpPushPushFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FTPPushPushFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of files to push"
+ ::= { ftpPush 8 }
+ --1.3.6.1.4.1.3052.10.2.4.9.8
+
+ftpPushPushFileEntry OBJECT-TYPE
+ SYNTAX FTPPushPushFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of files to push"
+ INDEX { ftpPushPushFileIndex }
+ ::= { ftpPushPushFileTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.9.8.1
+
+ftpPushPushFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of files to push"
+ ::= { ftpPushPushFileEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.9.8.1.1
+
+ftpPushPushFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push this local FILEx"
+ ::= { ftpPushPushFileEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.9.8.1.2
+
+ftpPushPushAudit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push the audit log"
+ ::= { ftpPush 9 }
+ --1.3.6.1.4.1.3052.10.2.4.9.9
+
+ftpPushPushAlarms OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push the alarms/events file"
+ ::= { ftpPush 10 }
+ --1.3.6.1.4.1.3052.10.2.4.9.10
+
+ftpPushRemoteFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FTPPushRemoteFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of remote names of files to push"
+ ::= { ftpPush 11 }
+ --1.3.6.1.4.1.3052.10.2.4.9.11
+
+ftpPushRemoteFileEntry OBJECT-TYPE
+ SYNTAX FTPPushRemoteFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of remote names of files to push"
+ INDEX { ftpPushRemoteFileIndex }
+ ::= { ftpPushRemoteFileTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.9.11.1
+
+ftpPushRemoteFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of remote names of files to push"
+ ::= { ftpPushRemoteFileEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.9.11.1
+
+ftpPushRemoteFileName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "remote name of pushed FILEx (name on server)"
+ ::= { ftpPushRemoteFileEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.9.11.2
+
+ftpPushRemoteAlarmName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filename on server for alarms"
+ ::= { ftpPush 12 }
+ --1.3.6.1.4.1.3052.10.2.4.9.12
+
+ftpPushPassive OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF use ftp passive mode"
+ ::= { ftpPush 13 }
+ --1.3.6.1.4.1.3052.10.2.4.9.13
+
+ftpPushIncludeDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include the date in the name of the pushed file"
+ ::= { ftpPush 14 }
+ --1.3.6.1.4.1.3052.10.2.4.9.14
+
+ftpPushIncludeTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include the time in the name of the pushed file"
+ ::= { ftpPush 15 }
+ --1.3.6.1.4.1.3052.10.2.4.9.15
+
+ftpPushIncludeSeq OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include a sequence number in the name of the pushed file"
+ ::= { ftpPush 16 }
+ --1.3.6.1.4.1.3052.10.2.4.9.16
+
+ftpPushPermissions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Unix permissions to apply to pushed files (octal notation)."
+ ::= { ftpPush 17 }
+ --1.3.6.1.4.1.3052.10.2.4.9.17
+
+
+pppDialEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF PPP dialout enabled"
+ ::= { pppDial 1 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.1
+
+pppDialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "phone number to dial"
+ ::= { pppDial 2 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.2
+
+pppDialIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds of inactivity after which the unit disconnects"
+ ::= { pppDial 5 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.5
+
+pppDialRetries OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of dialing retries for PPP"
+ ::= { pppDial 6 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.6
+
+pppDialCDTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds to wait after dialing for CD before
+ giving up"
+ ::= { pppDial 7 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.7
+
+pppDialLoginTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait to negotiate PPP after connecting"
+ ::= { pppDial 8 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.8
+
+pppDialMdmInit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem init string to use when dialing PPP"
+ ::= { pppDial 9 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.9
+
+pppDialSuggestIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address to suggest as the unit's end (local end) of the
+ PPP link"
+ ::= { pppDial 10 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.10
+
+pppDialPlainLogin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF look for login/password prompt before negotiating
+ PPP"
+ ::= { pppDial 11 }
+ --1.3.6.1.4.1.3052.10.2.4.10.1.11
+
+pppHostEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Unit accepts PPP negotiation"
+ ::= { pppHost 1 }
+ --1.3.6.1.4.1.3052.10.2.4.10.2.1
+
+pppHostIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds of inactivity after which PPP-hosted link will
+ terminate"
+ ::= { pppHost 2 }
+ --1.3.6.1.4.1.3052.10.2.4.10.2.2
+
+pppHostLocalIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Local IP address to negotiate"
+ ::= { pppHost 3 }
+ --1.3.6.1.4.1.3052.10.2.4.10.2.3
+
+pppHostRemoteIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote IP address to hand out to PPP peer"
+ ::= { pppHost 4 }
+ --1.3.6.1.4.1.3052.10.2.4.10.2.4
+
+-- Routing
+
+pppRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit routes IP traffic from PPP/Wireless to Ethernet"
+ ::= { routing 1 }
+ --1.3.6.1.4.1.3052.10.2.4.11.1
+
+ethRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit routes IP traffic from Ethernet to PPP/Wireless"
+ ::= { routing 2 }
+ --1.3.6.1.4.1.3052.10.2.4.11.2
+
+ethRoutingNATEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit applies NAT on routed IP frames egressing the
+ unit on its PPP interface"
+ ::= { routing 3 }
+ --1.3.6.1.4.1.3052.10.2.4.11.3
+
+routingInterface OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When Ethernet routing is enabled (routing.1), this is the
+ Ethernet interface to which IP frames received on PPP are
+ routed"
+ ::= { routing 4 }
+ --1.3.6.1.4.1.3052.10.2.4.11.4
+
+eth2WanRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Make ETH2 operate as a WAN port to route outbound traffic
+ arriving on ETH1."
+ ::= { routing 5 }
+ --1.3.6.1.4.1.3052.10.2.4.11.5
+
+-- IP Restrictions
+
+ipRestrictionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IPRestrictionConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of IP restrictions"
+ ::= { ipRestriction 1 }
+ --1.3.6.1.4.1.3052.10.2.4.12.1.1
+
+ipRestrictionEntry OBJECT-TYPE
+ SYNTAX IPRestrictionConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of IP restrictions"
+ INDEX { ipRestrictionIndex }
+ ::= { ipRestrictionTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.12.1.1
+
+ipRestrictionIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of IP restrictions"
+ ::= { ipRestrictionEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.12.1.1.1.1
+
+ipRestrictionEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this IP restriction"
+ ::= { ipRestrictionEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.12.1.1.1.2
+
+ipRestrictionMask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP restriction mask"
+ ::= { ipRestrictionEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.4.12.1.1.1.3
+
+
+-- RTS
+
+
+rtsFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RTSFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of RTS files"
+ ::= { rts 1 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1
+
+rtsFileEntry OBJECT-TYPE
+ SYNTAX RTSFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of RTS files"
+ INDEX { rtsFileIndex }
+ ::= { rtsFileTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1
+
+rtsFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of RTS files"
+ ::= { rtsFileEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.1
+
+rtsFileMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RTS mode (OFF,LISTEN,PUSH) for FILEx"
+ ::= { rtsFileEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.2
+
+rtsFileShowAnswer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Show answer string upon RTS connect for FILEx"
+ ::= { rtsFileEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.3
+
+rtsFileReqXON OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF require XON to start flow for FILEx"
+ ::= { rtsFileEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.4
+
+rtsFileTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Idle connection close timer (0 means no timeout) for FILEx"
+ ::= { rtsFileEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.5
+
+rtsFileEmptyClose OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF close the socket when FILEx is empty"
+ ::= { rtsFileEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.6
+
+rtsFilePushHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Host to which FILEx should be pushed via RTS"
+ ::= { rtsFileEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.7
+
+rtsFilePushPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port to which FILEx should be pushed via RTS"
+ ::= { rtsFileEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.8
+
+rtsFilePushRetryTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Retry timer (seconds) for retrying failed RTS push connect
+ attempts"
+ ::= { rtsFileEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.4.13.1.1.9
+
+-- RTS Alarms
+
+rtsAlarmsMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RTS mode (OFF,LISTEN,PUSH) for alarms file"
+ ::= { rtsAlarms 1 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2.1
+
+rtsAlarmsShowAnswer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Show answer string upon RTS connect for alarms file"
+ ::= { rtsAlarms 2 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2.2
+
+rtsAlarmsReqXON OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF require XON to start flow for alarms file"
+ ::= { rtsAlarms 3 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2.3
+
+rtsAlarmsTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Idle connection close timer (0 means no timeout) for alarms
+ file"
+ ::= { rtsAlarms 4 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2.4
+
+rtsAlarmsEmptyClose OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF close the socket when this file is empty for alarms
+ file"
+ ::= { rtsAlarms 5 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2.5
+
+rtsAlarmsPushHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Host to which alarms file should be pushed via RTS"
+ ::= { rtsAlarms 6 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2.6
+
+rtsAlarmsPushPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port to which alarms file should be pushed via RTS"
+ ::= { rtsAlarms 7 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2.7
+
+rtsAlarmsPushRetryTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Retry timer (seconds) for retrying failed RTS push connect
+ attempts"
+ ::= { rtsAlarms 8 }
+ --1.3.6.1.4.1.3052.10.2.4.13.2.8
+
+-- Traps
+
+trapIncludeDateTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include date and time in stock trap message"
+ ::= { trapInclude 1 }
+ --1.3.6.1.4.1.3052.10.2.4.14.1.1
+
+trapIncludeSiteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include site name in stock trap message"
+ ::= { trapInclude 2 }
+ --1.3.6.1.4.1.3052.10.2.4.14.1.2
+
+trapIncludeSensorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include sensor ID in stock trap message"
+ ::= { trapInclude 3 }
+ --1.3.6.1.4.1.3052.10.2.4.14.1.3
+
+trapIncludeUDName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include user defined name in stock trap message"
+ ::= { trapInclude 4 }
+ --1.3.6.1.4.1.3052.10.2.4.14.1.4
+
+trapIncludeUDState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include user defined state in stock trap message"
+ ::= { trapInclude 5 }
+ --1.3.6.1.4.1.3052.10.2.4.14.1.5
+
+trapIncludeSourceAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include source IP address in stock trap message"
+ ::= { trapInclude 6 }
+ --1.3.6.1.4.1.3052.10.2.4.14.1.6
+
+trapAuthFailEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable trap sent upon SNMP authentication failure"
+ ::= { trap 2 }
+ --1.3.6.1.4.1.3052.10.2.4.14.2
+
+-- Route testing
+
+routeTestEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable route testing"
+ ::= { routeTest 1 }
+ --1.3.6.1.4.1.3052.10.2.4.15.1
+
+
+routeTestPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The period which a route is considered valid"
+ ::= { routeTest 2 }
+ --1.3.6.1.4.1.3052.10.2.4.15.2
+
+routeTestAddressTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RouteTestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of route testing addresses"
+ ::= { routeTest 3 }
+ --1.3.6.1.4.1.3052.10.2.4.15.3
+
+routeTestAddressEntry OBJECT-TYPE
+ SYNTAX RouteTestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of RTS files"
+ INDEX { routeTestAddressIndex }
+ ::= { routeTestAddressTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.15.3.1
+
+routeTestAddressIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of RTS files"
+ ::= { routeTestAddressEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.15.3.1.1
+
+routeTestAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Address to ping to see if the route to it is valid"
+ ::= { routeTestAddressEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.15.3.1.2
+
+
+-- Wireless
+
+
+wirelessMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless mode (OFF,PERMANENT-EDGE)"
+ ::= { wireless 1 }
+ --1.3.6.1.4.1.3052.10.2.4.16.1
+
+wirelessAPN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless access point name"
+ ::= { wireless 2 }
+ --1.3.6.1.4.1.3052.10.2.4.16.2
+
+wirelessIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless idle timeout"
+ ::= { wireless 3 }
+ --1.3.6.1.4.1.3052.10.2.4.16.3
+
+wirelessDRE OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Default route enable for wireless network interface.
+ When this is ON, the wireless link, if up, becomes
+ the default route, overriding the default route setting
+ (defaultRouter object). When OFF, the default route
+ setting controls the default route and the wireless link
+ does not become the default route."
+ ::= { wireless 9 }
+ --1.3.6.1.4.1.3052.10.2.4.16.9
+
+wirelessPPPUsername OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Username for PPP-based wireless modem connections."
+ ::= { wireless 10 }
+ --1.3.6.1.4.1.3052.10.2.4.16.10
+
+wirelessFirewall OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem firewall."
+ ::= { wireless 11 }
+ --1.3.6.1.4.1.3052.10.2.4.16.11
+
+wirelessKeepaliveThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes of no RX activity before sending keep-alive."
+ ::= { wireless 12 }
+ --1.3.6.1.4.1.3052.10.2.4.16.12
+
+wirelessPPPDebug OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem PPP debug."
+ ::= { wireless 13 }
+ --1.3.6.1.4.1.3052.10.2.4.16.13
+
+wirelessConnEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem connectivity check."
+ ::= { wirelessConnectivity 1 }
+ --1.3.6.1.4.1.3052.10.2.4.16.20.1
+
+wirelessConnCheckInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check interval in minutes."
+ ::= { wirelessConnectivity 2 }
+ --1.3.6.1.4.1.3052.10.2.4.16.20.2
+
+wirelessConnFailThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity fail threshold."
+ ::= { wirelessConnectivity 3 }
+ --1.3.6.1.4.1.3052.10.2.4.16.20.3
+
+wirelessConnIP1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check IP address 1."
+ ::= { wirelessConnectivity 10 }
+ --1.3.6.1.4.1.3052.10.2.4.16.20.10
+
+wirelessConnIP2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check IP address 2."
+ ::= { wirelessConnectivity 11 }
+ --1.3.6.1.4.1.3052.10.2.4.16.20.11
+
+
+-- Email
+
+
+emailServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SMTP server to which the unit sends email"
+ ::= { email 1 }
+ --1.3.6.1.4.1.3052.10.2.4.17.1
+
+emailDomain OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Domain to use in recipient address"
+ ::= { email 2 }
+ --1.3.6.1.4.1.3052.10.2.4.17.2
+
+emailAuthEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable SMTP authentication"
+ ::= { email 3 }
+ --1.3.6.1.4.1.3052.10.2.4.17.3
+
+-- Advanced network config
+
+arpFilter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ARP filter code"
+ ::= { netAdvanced 1 }
+ --1.3.6.1.4.1.3052.10.2.4.18.1
+
+
+-- Web interface
+
+webEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for the web interface"
+ ::= { web 1 }
+ --1.3.6.1.4.1.3052.10.2.4.19.1
+
+webPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which web interface listens"
+ ::= { web 2 }
+ --1.3.6.1.4.1.3052.10.2.4.19.2
+
+webTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Web interface session timeout (seconds)"
+ ::= { web 3 }
+ --1.3.6.1.4.1.3052.10.2.4.19.3
+
+
+-- XML Proxy
+
+wxpEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Globally enables/disables the XML Proxy feature. This feature
+ is not available in the STD software build."
+ ::= { webXMLProxy 1 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.1
+
+wxpDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WebXMLProxyDeviceConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of XML Proxy devices."
+ ::= { webXMLProxy 2 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2
+
+wxpDeviceEntry OBJECT-TYPE
+ SYNTAX WebXMLProxyDeviceConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of XML Proxy devices."
+ INDEX { wxpDeviceIndex }
+ ::= { wxpDeviceTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1
+
+wxpDeviceIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of XML Proxy devices."
+ ::= { wxpDeviceEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.1
+
+wxpDeviceEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables/disables this particular XML device configuration."
+ ::= { wxpDeviceEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.2
+
+wxpDeviceIPAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address for device."
+ ::= { wxpDeviceEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.3
+
+wxpDevicePort OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which to connect via HTTP to fetch the XML file."
+ ::= { wxpDeviceEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.4
+
+wxpDeviceRemoteFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Path and name of the XML file on the remote device. E.g.,
+ 'xml/telemetry.xml' if the URL for the XML is
+ 'http://<remote device address>/xml/telemetry.xml'."
+ ::= { wxpDeviceEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.5
+
+wxpDeviceLocalFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of file in which the remote file content will be cached
+ on the unit. E.g., 'alpha-telemetry.xml' if the URL for the
+ unit-cached XML is intended to be
+ 'http://<unit address>/xmlproxy/alpha-telemetry.xml'."
+ ::= { wxpDeviceEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.6
+
+wxpDeviceTimeout OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How long in seconds to wait for the device to serve the
+ remote file before cancelling the fetch operation."
+ ::= { wxpDeviceEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.7
+
+wxpDeviceTimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timestamp of last successful XML file fetch/cache operation.
+ If blank then either the device is not configured or there
+ was a fetch error. If not blank, but not updating, then this
+ indicates that the fetch succeeded at one point but then
+ encountered an error."
+ ::= { wxpDeviceEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.4.19.4.2.1.8
+
+
+-- Ethernet Expansion
+
+ethExpanIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPv4 address of the unit reachable by nodes on the network interface
+ consisting of the Ethernet Expansion Card(s). If this is default
+ (0.0.0.0), then each card will still convey Ethernet traffic
+ (acting as Ethernet switch) among its nodes but those nodes will not
+ be able to communicate with the unit."
+ ::= { ethExpan 1 }
+ --1.3.6.1.4.1.3052.10.2.4.20.1
+
+ethExpanMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IPv4 subnet mask for the Ethernet Expansion network interface."
+ ::= { ethExpan 2 }
+ --1.3.6.1.4.1.3052.10.2.4.20.2
+
+ethExpanCardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EthernetExpansionCardConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of Ethernet Expansion cards"
+ ::= { ethExpan 3 }
+ --1.3.6.1.4.1.3052.10.2.4.20.3
+
+ethExpanCardEntry OBJECT-TYPE
+ SYNTAX EthernetExpansionCardConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of Ethernet Expansion cards"
+ INDEX { ethExpanCardIndex }
+ ::= { ethExpanCardTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.20.3.1
+
+ethExpanCardIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of Ethernet Expansion cards"
+ ::= { ethExpanCardEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.20.3.1.1
+
+ethExpanCardMAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MAC address for each Ethernet Expansion Card that is bridged
+ together to form the Ethernet Expansion network interface."
+ ::= { ethExpanCardEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.20.3.1.2
+
+ethExpanDHCPStartIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Starting IP address for serving DHCP addresses on the Ethernet
+ Expansion network interface. If this is default (0.0.0.0) then
+ the unit will not run DHCP to serve addresses."
+ ::= { ethExpanDHCP 1 }
+ --1.3.6.1.4.1.3052.10.2.4.20.6.1
+
+ethExpanDHCPLeaseTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lease time for Ethernet Expansion DHCP clients in minutes."
+ ::= { ethExpanDHCP 2 }
+ --1.3.6.1.4.1.3052.10.2.4.20.6.2
+
+
+
+-- IPv6
+
+ipv6DefaultRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 default router in use."
+ ::= { ipv6 1 }
+ --1.3.6.1.4.1.3052.10.2.4.21.1
+
+
+
+-- CPE table
+
+cpeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CPEConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CPEs"
+ ::= { cpe 1 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1
+
+cpeEntry OBJECT-TYPE
+ SYNTAX CPEConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CPEs"
+ INDEX { cpeIndex }
+ ::= { cpeTable 1 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1
+
+cpeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CPEs"
+ ::= { cpeEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.1
+
+cpeHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE host (IP address or DNS name)"
+ ::= { cpeEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.2
+
+cpeName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE name, informational only"
+ ::= { cpeEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.3
+
+cpeDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE description, informational only"
+ ::= { cpeEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.4
+
+cpeKeepalive OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds between each successful ping request."
+ ::= { cpeEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.5
+
+cpeThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of unsuccessful pings that triggers the CPE event."
+ ::= { cpeEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.6
+
+cpeEventReminderInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE event reminder interval (minutes)."
+ ::= { cpeEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.7
+
+cpeKeepaliveTicks OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE ping period in 16ths of a second (nonzero overrides keepalive)."
+ ::= { cpeEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.20
+
+cpePingSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of bytes in CPE ping payload"
+ ::= { cpeEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.11
+
+cpeInfoReset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Set any number to reset CPE ping stats."
+ ::= { cpeEntry 30 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.30
+
+cpeInfoNumReq OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of requests transmitted."
+ ::= { cpeEntry 31 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.31
+
+cpeInfoNumGoodResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of non-corrupt responses."
+ ::= { cpeEntry 32 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.32
+
+cpeInfoNumBadResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of corrupt responses."
+ ::= { cpeEntry 33 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.33
+
+cpeInfoNumLostResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of requests with no response."
+ ::= { cpeEntry 34 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.34
+
+cpeInfoPercentLoss OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent loss (missing responses / total requests)."
+ ::= { cpeEntry 35 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.35
+
+cpeInfoPercentBad OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent corrupt (corrupt responses / total requests)."
+ ::= { cpeEntry 36 }
+ --1.3.6.1.4.1.3052.10.2.4.22.1.1.36
+
+
+-- DNP3
+
+dnp3Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNP3 operating mode."
+ ::= { dnp3General 1 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.1
+
+dnp3SelfAddressEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNP3 self-address enabled."
+ ::= { dnp3General 2 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.2
+
+dnp3KeepaliveTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Keepalive timeout in seconds."
+ ::= { dnp3General 3 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.3
+
+dnp3MaxRXFragmentSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum size of a received fragment in bytes."
+ ::= { dnp3General 4 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.4
+
+dnp3MaxTXFragmentSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum size of a transmitted fragment in bytes."
+ ::= { dnp3General 5 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.5
+
+dnp3UnsolResponseEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable unsolicited responses."
+ ::= { dnp3General 6 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.6
+
+dnp3UnsolResponseTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Unsolicited response confirmation timeout in seconds."
+ ::= { dnp3General 7 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.7
+
+dnp3UnsolResponseRetries OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Unsolicited response confirmation timeout retries."
+ ::= { dnp3General 8 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.8
+
+dnp3LogFilter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Numeric code to describe what gets logged (for support/troubleshooting analysis only)."
+ ::= { dnp3General 9 }
+ --1.3.6.1.4.1.3052.10.2.4.23.1.9
+
+dnp3OutstationTCPPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which to listen for connections."
+ ::= { dnp3Outstation 1 }
+ --1.3.6.1.4.1.3052.10.2.4.23.2.1
+
+dnp3OutstationDNP3Address OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNP3 address of the outstation. "
+ ::= { dnp3Outstation 2 }
+ --1.3.6.1.4.1.3052.10.2.4.23.2.2
+
+dnp3OutstationMasterIPAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP (v4 or v6) address (non-resolved) of the intended master. Default blank.
+ If non-blank then the outstation drops connections from TCP clients not at this address."
+ ::= { dnp3Outstation 3 }
+ --1.3.6.1.4.1.3052.10.2.4.23.2.3
+
+dnp3OutstationMasterDNP3Address OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNP3 address of the intended master upon connection. Range 0 - 65520, default 65520.
+ If set to 0 - 65519 then the outstation discards DNP3 data link frames not from this
+ address. 65520 is not a valid DNP3 address; if set to 65520 then it means the
+ outstation accepts frames from any address."
+ ::= { dnp3Outstation 4 }
+ --1.3.6.1.4.1.3052.10.2.4.23.2.4
+
+dnp3OutstationUnsolResponseDNP3Address OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNP3 destination address of unsolicited responses. Range 0 - 65520, default 65520.
+ If set to 65520 then it means the outstation addresses data link frames of
+ unsolicited responses to the source address of the last accepted frame received
+ from the master."
+ ::= { dnp3Outstation 5 }
+ --1.3.6.1.4.1.3052.10.2.4.23.2.5
+
+
+
+dnp3DuplicateFragmentCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of duplicate fragments received."
+ ::= { dnp3Error 1 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.1
+
+dnp3CollidingFragmentCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of colliding fragments received."
+ ::= { dnp3Error 2 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.2
+
+dnp3UnsolResponseCfmFailCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of unsolicited response confirmation failures."
+ ::= { dnp3Error 3 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.3
+
+dnp3SolCfmFailCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of solicited response confirmation failures."
+ ::= { dnp3Error 4 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.4
+
+dnp3ObjParseErrorCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of received data object parse errors."
+ ::= { dnp3Error 5 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.5
+
+dnp3FrameParseErrorCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of received frame parse errors."
+ ::= { dnp3Error 6 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.6
+
+dnp3DiscardedFrameCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of received frames discarded."
+ ::= { dnp3Error 7 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.7
+
+dnp3BadBlockCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of received frame blocks with bad CRC."
+ ::= { dnp3Error 8 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.8
+
+dnp3UnsolResponseRetryCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of retried unsolicited responses."
+ ::= { dnp3Error 9 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.9
+
+dnp3UnsupportedFrameCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of received frames accepted (good CRC and addressed to
+ the outstation) with an unsupported data link function code."
+ ::= { dnp3Error 10 }
+ --1.3.6.1.4.1.3052.10.2.4.23.4.10
+
+
+dnp3OutstationCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of running outstation instances."
+ ::= { dnp3Status 1 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.1
+
+dnp3ConnPeer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of the connected peer (the TCP socket endpoint of the master)."
+ ::= { dnp3Status 2 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.2
+
+dnp3StartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When the outstation instance started."
+ ::= { dnp3Status 3 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.3
+
+dnp3EventAwaitingSolCfmCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of events reported and awaiting solicited confirmation; usually 0."
+ ::= { dnp3Status 4 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.4
+
+dnp3EventAwaitingUnsolCfmCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of events reported and awaiting unsolicited confirmation; usually 0."
+ ::= { dnp3Status 5 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.5
+
+dnp3EventCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of total events buffered (that is, existing, maybe reported, but not confirmed)."
+ ::= { dnp3Status 6 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.6
+
+dnp3EventClass1Count OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Portion of the total events buffered that are class 1 events."
+ ::= { dnp3Status 7 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.7
+
+dnp3EventClass2Count OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Portion of the total events buffered that are class 2 events."
+ ::= { dnp3Status 8 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.8
+
+dnp3EventClass3Count OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Portion of the total events buffered that are class 3 events."
+ ::= { dnp3Status 9 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.9
+
+dnp3RxFragmentTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time of the last fragment received."
+ ::= { dnp3Status 10 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.10
+
+dnp3TxFragmentTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time of the last fragment transmitted."
+ ::= { dnp3Status 11 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.11
+
+dnp3TxCachedResponseCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of cached responses transmitted."
+ ::= { dnp3Status 12 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.12
+
+dnp3TxUnsolResponseCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of unsolicited responses transmitted."
+ ::= { dnp3Status 13 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.13
+
+dnp3TxSolResponseCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of solicited responses transmitted."
+ ::= { dnp3Status 14 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.14
+
+dnp3TxFragmentReqCfmCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of fragments transmitted that required confirmation."
+ ::= { dnp3Status 15 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.15
+
+dnp3RxUnsolResponseCfmCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of unsolicited response confirmations received."
+ ::= { dnp3Status 16 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.16
+
+dnp3RxSolResponseCfmCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of solicited response confirmations received."
+ ::= { dnp3Status 17 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.17
+
+dnp3RxFunctionCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of total application function codes received."
+ ::= { dnp3Status 18 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.18
+
+dnp3RxReadFunctionCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of read application function codes received."
+ ::= { dnp3Status 19 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.19
+
+dnp3RxWriteFunctionCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of write application function codes received."
+ ::= { dnp3Status 20 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.20
+
+dnp3RxDirOpFunctionCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of direct operate application function codes received."
+ ::= { dnp3Status 21 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.21
+
+dnp3RxEnableURCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of enable unsolicited application function codes received."
+ ::= { dnp3Status 22 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.22
+
+dnp3RxDisableURCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of disabled unsolicited application function codes received."
+ ::= { dnp3Status 23 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.23
+
+dnp3RxSolObjectCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of data objects received in solicited requests."
+ ::= { dnp3Status 40 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.40
+
+dnp3TxSolObjectCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of data objects transmitted in solicted responses."
+ ::= { dnp3Status 41 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.41
+
+dnp3RxFrameTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time of the last frame received."
+ ::= { dnp3Status 42 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.42
+
+dnp3TxFrameTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time of the last frame transmitted."
+ ::= { dnp3Status 43 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.43
+
+dnp3TxFrameCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of total frames transmitted."
+ ::= { dnp3Status 44 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.44
+
+dnp3RxAcceptedFrameCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of total frames accepted."
+ ::= { dnp3Status 45 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.45
+
+dnp3RxSupportedFrameCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Count of total frames accepted with a supported data link function code."
+ ::= { dnp3Status 46 }
+ --1.3.6.1.4.1.3052.10.2.4.23.5.46
+
+
+--***************************************************************************************
+--Modem Section 2.5
+--***************************************************************************************
+
+
+
+
+
+modemFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem data format (8N1,7E1,7O1,7N1)"
+ ::= { modem 1 }
+ --1.3.6.1.4.1.3052.10.2.5.1
+
+modemInitString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Init string for modem"
+ ::= { modem 2 }
+ --1.3.6.1.4.1.3052.10.2.5.2
+
+
+modemCallAttempts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Max mumber of times the modem should try to call out until
+ successful connect"
+ ::= { modem 4 }
+ --1.3.6.1.4.1.3052.10.2.5.4
+
+modemCallDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum delay (seconds) between callouts"
+ ::= { modem 5 }
+ --1.3.6.1.4.1.3052.10.2.5.6
+
+
+modemCmdTimout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of minutes after which an idle command session via
+ modem is terminated"
+ ::= { modem 6 }
+ --1.3.6.1.4.1.3052.10.2.5.6
+
+modemGoto OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When a user connects, where that user is routed (command
+ session, passthrough to port 1, passthrough to port 2, etc.)"
+ ::= { modem 7 }
+ --1.3.6.1.4.1.3052.10.2.5.7
+
+
+modemCLIDEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Calling Line Identification security"
+ ::= { modemClid 1 }
+ --1.3.6.1.4.1.3052.10.2.5.8.1
+
+
+modemCLIDNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ModemCLIDNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of authorized callers identified by phone number"
+ ::= { modemClid 2 }
+ --1.3.6.1.4.1.3052.10.2.5.8.2
+
+modemCLIDNumberEntry OBJECT-TYPE
+ SYNTAX ModemCLIDNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CLID numbers"
+ INDEX { modemCLIDNumberIndex }
+ ::= { modemCLIDNumberTable 1 }
+ --1.3.6.1.4.1.3052.10.2.5.8.2.1
+
+modemCLIDNumberIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CLID numbers"
+ ::= { modemCLIDNumberEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.5.8.2.1.1
+
+modemCLIDNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "auhorized CLID number"
+ ::= { modemCLIDNumberEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.5.8.2.1.2
+
+modemTAPInitString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Init string to use for TAP (pager) connections"
+ ::= { modem 9 }
+ --1.3.6.1.4.1.3052.10.2.5.9
+
+modemTAP8N1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: use 8N1 data/parity/stop for TAP connections"
+ ::= { modem 10 }
+ --1.3.6.1.4.1.3052.10.2.5.10
+
+
+--***************************************************************************************
+--Time Section 2.8
+--***************************************************************************************
+
+clock OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text string for date and time;
+ e.g. 'SUN 01/02/98 12:34:27'. When setting
+ this object, only the date and time are
+ required; the unit will ignore a specified
+ day of week because it is calculated from
+ the date and time. When this object is included
+ in a notification as a varbind, it represents
+ the time that the triggering event occurred."
+ ::= { time 1 }
+ --1.3.6.1.4.1.3052.10.2.8.1
+
+--***************************************************************************************
+--Console Section 2.10
+--***************************************************************************************
+
+
+consoleDuplex OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF characters echoed on telnet command session"
+ ::= { console 1 }
+ --1.3.6.1.4.1.3052.10.2.10.1
+
+consoleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes of inactivity after which telnet command session is terminated"
+ ::= { console 2 }
+ --1.3.6.1.4.1.3052.10.2.10.2
+
+consoleConfirm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Prompt to confirm certain actions"
+ ::= { console 7 }
+ --1.3.6.1.4.1.3052.10.2.10.7
+
+--***************************************************************************************
+--Core Security Section 2.11.1
+--***************************************************************************************
+
+scShowPasswordPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF show password prompt upon login"
+ ::= { secCore 1 }
+ --1.3.6.1.4.1.3052.10.2.11.1.1
+
+scConsoleLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via console"
+ ::= { secCore 2 }
+ --1.3.6.1.4.1.3052.10.2.11.1.2
+
+scModemLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via modem"
+ ::= { secCore 3 }
+ --1.3.6.1.4.1.3052.10.2.11.1.3
+
+scTelnetLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via Telnet"
+ ::= { secCore 4 }
+ --1.3.6.1.4.1.3052.10.2.11.1.4
+
+scTelnetPTLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via Telnet to pass-
+ through ports (TCP ports 210x)"
+ ::= { secCore 5 }
+ --1.3.6.1.4.1.3052.10.2.11.1.5
+
+scRTSLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting to RTS (TCP ports 220x)"
+ ::= { secCore 6 }
+ --1.3.6.1.4.1.3052.10.2.11.1.6
+
+scAuthMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Authentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)"
+ ::= { secCore 7 }
+ --1.3.6.1.4.1.3052.10.2.11.1.7
+
+scRightsGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The set of aliases used for the 8 available rights levels"
+ ::= { secCore 8 }
+ --1.3.6.1.4.1.3052.10.2.11.1.8
+
+
+--***************************************************************************************
+--User Security Section 2.11.2
+--***************************************************************************************
+
+
+secUserTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SecUserConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of users"
+ ::= { unitSecurity 2 }
+ --1.3.6.1.4.1.3052.10.2.11.2
+
+secUserEntry OBJECT-TYPE
+ SYNTAX SecUserConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of users"
+ INDEX { secUserIndex }
+ ::= { secUserTable 1 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1
+
+secUserIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of users"
+ ::= { secUserEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.1
+
+secUserEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable user"
+ ::= { secUserEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.2
+
+secUserConnectVia OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Methods by which user is allowed to connect:
+ L=local (console)
+ T=Telnet
+ M=modem
+ F=FTP
+ R=RTS
+ S=SSH
+ "
+ ::= { secUserEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.5
+
+secUserLoginTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The function presented to the user upon login (COMMAND,
+ PASSTHROUGH,MENU)"
+ ::= { secUserEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.6
+
+secUserAccessFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default access file associated with the user"
+ ::= { secUserEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.7
+
+secUserPTEscapeTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The function presented to the user upon escaping pass-
+ through: currently only MENU"
+ ::= { secUserEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.9
+
+secUserPPPType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The kind of PPP access allowed to this user cannot connect
+ via PPP (NONE), can connect but only to the unit (LOCAL), or
+ can connect and route to Ethernet (ROUTING)"
+ ::= { secUserEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.10
+
+secUserRights OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The rights level granted to this user"
+ ::= { secUserEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.11
+
+secUserEventsReadAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to read the events/alarms file"
+ ::= { secUserEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.13
+
+secUserAuditReadAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to read the audit log"
+ ::= { secUserEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.14
+
+secUserEventsWriteAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to delete the events file"
+ ::= { secUserEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.16
+
+secUserAuditWriteAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to write to the audit log"
+ ::= { secUserEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.17
+
+secUserExpiration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Expiration date/time of this user"
+ ::= { secUserEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.18
+
+secUserCallbackNumber1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 1 the unit calls for dialback"
+ ::= { secUserEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.19
+
+secUserCallbackNumber2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 2 the unit calls for dialback"
+ ::= { secUserEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.20
+
+secUserCallbackNumber3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 3 the unit calls for dialback"
+ ::= { secUserEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.21
+
+secUserChallengeTelnetMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Telnet challenge mode: when user logs in via telnet, unit
+ allows access (OFF), presents a challenge (CHALLENGE), or
+ unit sends a one-time-password (SEND PASSWORD) to a
+ destination configured by secUserChallengeTelnetSendTo"
+ ::= { secUserEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.22
+
+secUserChallengeModemMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem challenge mode: when user logs in via modem, unit
+ allows access (OFF), presents a challenge (CHALLENGE), sends
+ a one-time-password (SEND PASSWORD) to a destination
+ configured by secUserChallengeTelnetSendTo, or dials a
+ number (CALLBACK) configured with secUserCallbackNumberx"
+ ::= { secUserEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.23
+
+secUserChallengeConsoleMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console challenge mode: when user logs in via console, unit
+ allows access (OFF), or presents a challenge (CHALLENGE)"
+ ::= { secUserEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.24
+
+secUserChallengeTelnetSendTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Email action used as the destination address for one-time-
+ password when a user logs in with a challenge mode of
+ SEND PASSWORD"
+ ::= { secUserEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.25
+
+secUserChallengeModemSendTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem action used as the destination phone number for one-
+ time-password when a user logs in with a challenge mode of
+ SEND PASSWORD"
+ ::= { secUserEntry 26 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.26
+
+secUserChallengeExpiration OBJECT-TYPE
+ SYNTAX Integer32 (0..180)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time (in minutes) after which a one-time-password is sent
+ that it can be used to log in"
+ ::= { secUserEntry 27 }
+ --1.3.6.1.4.1.3052.10.2.11.2.1.27
+
+
+--***************************************************************************************
+--Factory Security Section 2.11.3
+--***************************************************************************************
+
+sfEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable factory access"
+ ::= { secFactory 1 }
+ --1.3.6.1.4.1.3052.10.2.11.3.1
+
+sfSecret OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Secret used for factory access"
+ ::= { secFactory 2 }
+ --1.3.6.1.4.1.3052.10.2.11.3.2
+
+
+--***************************************************************************************
+--SSH Security Section 2.11.3
+--***************************************************************************************
+
+--***************************************************************************************
+--Event Section 2.12
+--***************************************************************************************
+
+--***************************************************************************************
+--Event Core Section 2.12.1
+--***************************************************************************************
+
+
+evClassNameTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventClassConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of classes"
+ ::= { evCore 1 }
+ --1.3.6.1.4.1.3052.10.2.12.1.1
+
+evClassNameEntry OBJECT-TYPE
+ SYNTAX EventClassConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of classes"
+ INDEX { evClassNameIndex }
+ ::= { evClassNameTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.1.1.1
+
+evClassNameIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of classes"
+ ::= { evClassNameEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.1.1.1.1
+
+evClassName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class name for this slot"
+ ::= { evClassNameEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.1.1.1.2
+
+evReminderInterval OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval (minutes) between EventSensor reminder events"
+ ::= { evCore 2 }
+ --1.3.6.1.4.1.3052.10.2.12.1.2
+
+evLogEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable event log"
+ ::= { evLog 1 }
+ --1.3.6.1.4.1.3052.10.2.12.1.3.1
+
+evLogStoreAlarm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF store data alarms in event log"
+ ::= { evLog 2 }
+ --1.3.6.1.4.1.3052.10.2.12.1.3.2
+
+evLogMaxSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "max size (in KB) of event log"
+ ::= { evLog 3 }
+ --1.3.6.1.4.1.3052.10.2.12.1.3.3
+
+evLogStoreSensor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF store EventSensor events in event log"
+ ::= { evLog 4 }
+ --1.3.6.1.4.1.3052.10.2.12.1.3.4
+
+evLogTimeStampAlarms OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF put timestamps on event log entries"
+ ::= { evLog 5 }
+ --1.3.6.1.4.1.3052.10.2.12.1.3.5
+
+evLogPrependName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF prepend data event name to data alarm records in event
+ log"
+ ::= { evLog 6 }
+ --1.3.6.1.4.1.3052.10.2.12.1.3.6
+
+
+evMgmtReprocess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of sensors that have generated events since reset.
+ Write this to reprocess each sensor's last generated event
+ since reset. The value to write determines what kind of
+ events should be reprocessed:
+ 'all': all sensor events
+ 'cc': cc events
+ 'temperature': temperature events
+ 'humidity': humidity events
+ 'analog': analog input events"
+ ::= { evMgmt 3 }
+ --1.3.6.1.4.1.3052.10.2.12.1.4.3
+
+
+
+--***************************************************************************************
+--Data event section 2.12.2
+--***************************************************************************************
+
+evdExitOnTrue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: Data alarm evaluator stops checking record against
+ alarm equations when it finds an equation that matches"
+ ::= { evdCore 1 }
+ --1.3.6.1.4.1.3052.10.2.12.2.1.1.1
+
+evdFilterAction OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "What happens to a record that matches an equation:
+ REJECT/ACCEPT"
+ ::= { evdCore 2 }
+ --1.3.6.1.4.1.3052.10.2.12.2.1.1.2
+
+evdWildCardChar OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Character (in decimal ASCII code format) used to indicate
+ wildcards in data alarm equation"
+ ::= { evdCore 3 }
+ --1.3.6.1.4.1.3052.10.2.12.2.1.1.3
+
+
+evdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data events"
+ ::= { evData 2 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2
+
+evdEntry OBJECT-TYPE
+ SYNTAX DataEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data events"
+ INDEX { evdIndex }
+ ::= { evdTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1
+
+evdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data events"
+ ::= { evdEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.1
+
+evdEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this data event"
+ ::= { evdEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.2
+
+evdName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this data event"
+ ::= { evdEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.3
+
+evdEquation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Equation for this data event"
+ ::= { evdEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.4
+
+evdThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of equation matches that must happen to trigger this
+ data event"
+ ::= { evdEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.5
+
+evdAutoClear OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF this data alarm is automatically cleared (re-armed)
+ upon reaching the threshold number of matches"
+ ::= { evdEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.6
+
+evdClearInterval OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval at which this alarm is automatically cleared (no
+ bearing with evdAutoClear)"
+ ::= { evdEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.7
+
+evdClearTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tie of day (HH:MM) at which this data alarm is cleared (no
+ bearing with evdAutoClear)"
+ ::= { evdEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.8
+
+evdActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this data event"
+ ::= { evdEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.9
+
+evdClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this data event"
+ ::= { evdEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.10
+
+evdTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this event"
+ ::= { evdEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.11
+
+evdMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ALARM/FILTER: what is happens when this data event
+ triggers: either generate actions (mode=ALARM) )or
+ ACCEPT/REJECT (via evdFilterAction) the record
+ (mode=FILTER)"
+ ::= { evdEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.2.2.1.12
+
+evdFieldTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventFieldConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data event fields"
+ ::= { evData 3 }
+ --1.3.6.1.4.1.3052.10.2.12.2.3
+
+evdFieldEntry OBJECT-TYPE
+ SYNTAX DataEventFieldConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data event fields"
+ INDEX { evdFieldIndex }
+ ::= { evdFieldTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.2.3.1
+
+evdFieldIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data event fields"
+ ::= { evdFieldEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.2.3.1.1
+
+evdFieldStart OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start position (1-based) for this data event field"
+ ::= { evdFieldEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.2.3.1.2
+
+evdFieldLength OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of characters this data event field occupies"
+ ::= { evdFieldEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.2.3.1.3
+
+evdFieldName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start position (1-based) for this data event field"
+ ::= { evdFieldEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.2.3.1.4
+
+evdFieldLine OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Line number (1-based, for multiline records) for this data
+ event field"
+ ::= { evdFieldEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.2.3.1.5
+
+evdFieldType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alpha/Numeric type for this data event field"
+ ::= { evdFieldEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.2.3.1.6
+
+evdMacroTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventMacroConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data event macros"
+ ::= { evData 4 }
+ --1.3.6.1.4.1.3052.10.2.12.2.4
+
+evdMacroEntry OBJECT-TYPE
+ SYNTAX DataEventMacroConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data event macros"
+ INDEX { evdMacroIndex }
+ ::= { evdMacroTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.2.4.1
+
+evdMacroIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data event macros"
+ ::= { evdMacroEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.2.4.1.1
+
+evdMacroName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of this macro for use in data event equations"
+ ::= { evdMacroEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.2.4.1.2
+
+evdMacroEquation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Equation for this data event macro"
+ ::= { evdMacroEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.2.4.1.3
+
+--***************************************************************************************
+--No data event 1 Section 2.12.3
+--***************************************************************************************
+
+evNoData1Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this no data event"
+ ::= { evNoData1 1 }
+ --1.3.6.1.4.1.3052.10.2.12.3.1
+
+evNoData1Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this no data event"
+ ::= { evNoData1 2 }
+ --1.3.6.1.4.1.3052.10.2.12.3.2
+
+evNoData1Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this no data event"
+ ::= { evNoData1 3 }
+ --1.3.6.1.4.1.3052.10.2.12.3.3
+
+evNoData1TrapNum OBJECT-TYPE
+ SYNTAX Integer32 (505..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this no data event"
+ ::= { evNoData1 4 }
+ --1.3.6.1.4.1.3052.10.2.12.3.4
+
+evNoData1Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this no data event"
+ ::= { evNoData1 5 }
+ --1.3.6.1.4.1.3052.10.2.12.3.5
+
+evNoData1Sched1Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 begin time (HH:MM) for this no data event"
+ ::= { evNoData1 6 }
+ --1.3.6.1.4.1.3052.10.2.12.3.6
+
+evNoData1Sched1End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 end time (HH:MM) for this no data event"
+ ::= { evNoData1 7 }
+ --1.3.6.1.4.1.3052.10.2.12.3.7
+
+evNoData1Sched1Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 1 of this no data event"
+ ::= { evNoData1 8 }
+ --1.3.6.1.4.1.3052.10.2.12.3.8
+
+evNoData1Sched2Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 begin time (HH:MM) for this no data event"
+ ::= { evNoData1 9 }
+ --1.3.6.1.4.1.3052.10.2.12.3.9
+
+evNoData1Sched2End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 end time (HH:MM) for this no data event"
+ ::= { evNoData1 10 }
+ --1.3.6.1.4.1.3052.10.2.12.3.10
+
+evNoData1Sched2Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 2 of this no data event"
+ ::= { evNoData1 11 }
+ --1.3.6.1.4.1.3052.10.2.12.3.11
+
+evNoData1PortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NoDataEvent1PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of no data event 1 port enables"
+ ::= { evNoData1 12 }
+ --1.3.6.1.4.1.3052.10.2.12.3.12
+
+evNoData1PortEnableEntry OBJECT-TYPE
+ SYNTAX NoDataEvent1PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of no data event 1 port enables"
+ INDEX { evNoData1PortEnableIndex }
+ ::= { evNoData1PortEnableTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.3.12.1
+
+evNoData1PortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of no data event 1 port enables"
+ ::= { evNoData1PortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.3.12.1.1
+
+evNoData1PortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: no data event 1 observes this port"
+ ::= { evNoData1PortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.3.12.1.2
+
+evNoData1Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ no data event"
+ ::= { evNoData1 13 }
+ --1.3.6.1.4.1.3052.10.2.12.3.13
+
+evNoData1Days OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Days of the week on which this no event is active"
+ ::= { evNoData1 14 }
+ --1.3.6.1.4.1.3052.10.2.12.3.14
+
+--***************************************************************************************
+--No data event 2 Section 2.12.4
+--***************************************************************************************
+
+evNoData2Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this no data event"
+ ::= { evNoData2 1 }
+ --1.3.6.1.4.1.3052.10.2.12.4.1
+
+evNoData2Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this no data event"
+ ::= { evNoData2 2 }
+ --1.3.6.1.4.1.3052.10.2.12.4.2
+
+evNoData2Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this no data event"
+ ::= { evNoData2 3 }
+ --1.3.6.1.4.1.3052.10.2.12.4.3
+
+evNoData2TrapNum OBJECT-TYPE
+ SYNTAX Integer32 (505..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this no data event"
+ ::= { evNoData2 4 }
+ --1.3.6.1.4.1.3052.10.2.12.4.4
+
+evNoData2Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this no data event"
+ ::= { evNoData2 5 }
+ --1.3.6.1.4.1.3052.10.2.12.4.5
+
+evNoData2Sched1Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 begin time (HH:MM) for this no data event"
+ ::= { evNoData2 6 }
+ --1.3.6.1.4.1.3052.10.2.12.4.6
+
+evNoData2Sched1End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 end time (HH:MM) for this no data event"
+ ::= { evNoData2 7 }
+ --1.3.6.1.4.1.3052.10.2.12.4.7
+
+evNoData2Sched1Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 1 of this no data event"
+ ::= { evNoData2 8 }
+ --1.3.6.1.4.1.3052.10.2.12.4.8
+
+evNoData2Sched2Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 begin time (HH:MM) for this no data event"
+ ::= { evNoData2 9 }
+ --1.3.6.1.4.1.3052.10.2.12.4.9
+
+evNoData2Sched2End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 end time (HH:MM) for this no data event"
+ ::= { evNoData2 10 }
+ --1.3.6.1.4.1.3052.10.2.12.4.10
+
+evNoData2Sched2Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 2 of this no data event"
+ ::= { evNoData2 11 }
+ --1.3.6.1.4.1.3052.10.2.12.4.11
+
+evNoData2PortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NoDataEvent2PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of no data event 2 port enables"
+ ::= { evNoData2 12 }
+ --1.3.6.1.4.1.3052.10.2.12.4.12
+
+evNoData2PortEnableEntry OBJECT-TYPE
+ SYNTAX NoDataEvent2PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of no data event 2 port enables"
+ INDEX { evNoData2PortEnableIndex }
+ ::= { evNoData2PortEnableTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.4.12.1
+
+evNoData2PortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of no data event 2 port enables"
+ ::= { evNoData2PortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.4.12.1.1
+
+evNoData2PortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: no data event 2 observes this port"
+ ::= { evNoData2PortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.4.12.1.2
+
+evNoData2Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ no data event"
+ ::= { evNoData2 13 }
+ --1.3.6.1.4.1.3052.10.2.12.4.13
+
+evNoData2Days OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Days of the week on which this no event is active"
+ ::= { evNoData2 14 }
+ --1.3.6.1.4.1.3052.10.2.12.4.14
+
+--***************************************************************************************
+--Scheduled Event 1 Section 2.12.5
+--***************************************************************************************
+
+evSched1Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this scheduled event"
+ ::= { evSched1 1 }
+ --1.3.6.1.4.1.3052.10.2.12.5.1
+
+evSched1Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this scheduled event"
+ ::= { evSched1 2 }
+ --1.3.6.1.4.1.3052.10.2.12.5.2
+
+evSched1Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this scheduled event"
+ ::= { evSched1 3 }
+ --1.3.6.1.4.1.3052.10.2.12.5.3
+
+evSched1TrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this scheduled event"
+ ::= { evSched1 4 }
+ --1.3.6.1.4.1.3052.10.2.12.5.4
+
+evSched1Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this scheduled event"
+ ::= { evSched1 5 }
+ --1.3.6.1.4.1.3052.10.2.12.5.5
+
+evSched1Sunday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Sunday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 6 }
+ --1.3.6.1.4.1.3052.10.2.12.5.6
+
+evSched1Monday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Monday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 7 }
+ --1.3.6.1.4.1.3052.10.2.12.5.7
+
+evSched1Tuesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Tuesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 8 }
+ --1.3.6.1.4.1.3052.10.2.12.5.8
+
+evSched1Wednesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Wednesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 9 }
+ --1.3.6.1.4.1.3052.10.2.12.5.9
+
+evSched1Thursday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Thursday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 10 }
+ --1.3.6.1.4.1.3052.10.2.12.5.10
+
+evSched1Friday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Friday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 11 }
+ --1.3.6.1.4.1.3052.10.2.12.5.11
+
+evSched1Saturday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Saturday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 12 }
+ --1.3.6.1.4.1.3052.10.2.12.5.12
+
+evSched1Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ scheduled event"
+ ::= { evSched1 13 }
+ --1.3.6.1.4.1.3052.10.2.12.5.13
+
+
+--***************************************************************************************
+--Scheduled Event 2 Section 2.12.6
+--***************************************************************************************
+
+evSched2Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this scheduled event"
+ ::= { evSched2 1 }
+ --1.3.6.1.4.1.3052.10.2.12.6.1
+
+evSched2Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this scheduled event"
+ ::= { evSched2 2 }
+ --1.3.6.1.4.1.3052.10.2.12.6.2
+
+evSched2Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this scheduled event"
+ ::= { evSched2 3 }
+ --1.3.6.1.4.1.3052.10.2.12.6.3
+
+evSched2TrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this scheduled event"
+ ::= { evSched2 4 }
+ --1.3.6.1.4.1.3052.10.2.12.6.4
+
+evSched2Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this scheduled event"
+ ::= { evSched2 5 }
+ --1.3.6.1.4.1.3052.10.2.12.6.5
+
+evSched2Sunday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Sunday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 6 }
+ --1.3.6.1.4.1.3052.10.2.12.6.6
+
+evSched2Monday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Monday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 7 }
+ --1.3.6.1.4.1.3052.10.2.12.6.7
+
+evSched2Tuesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Tuesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 8 }
+ --1.3.6.1.4.1.3052.10.2.12.6.8
+
+evSched2Wednesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Wednesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 9 }
+ --1.3.6.1.4.1.3052.10.2.12.6.9
+
+evSched2Thursday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Thursday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 10 }
+ --1.3.6.1.4.1.3052.10.2.12.6.10
+
+evSched2Friday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Friday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 11 }
+ --1.3.6.1.4.1.3052.10.2.12.6.11
+
+evSched2Saturday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Saturday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 12 }
+ --1.3.6.1.4.1.3052.10.2.12.6.12
+
+evSched2Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ scheduled event"
+ ::= { evSched2 13 }
+ --1.3.6.1.4.1.3052.10.2.12.6.13
+
+--***************************************************************************************
+--Serial Handshaking Low Section 2.12.7
+--***************************************************************************************
+
+evShskLowTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SerialHandshakingLowEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of serial handshaking low events"
+ ::= { event 7 }
+ --1.3.6.1.4.1.3052.10.2.12.7
+
+evShskLowEntry OBJECT-TYPE
+ SYNTAX SerialHandshakingLowEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of serial handshaking low events"
+ INDEX { evShskLowIndex }
+ ::= { evShskLowTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.7.1
+
+evShskLowIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of serial handshaking low events"
+ ::= { evShskLowEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.7.1.1
+
+evShskLowEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enable the serial handshaking low event for this port"
+ ::= { evShskLowEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.7.1.2
+
+evShskLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.7.1.3
+
+evShskLowMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.7.1.4
+
+evShskLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.7.1.5
+
+evShskLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.7.1.6
+
+
+--***************************************************************************************
+--Serial Handshaking High Section 2.12.8
+--***************************************************************************************
+
+evShskHighTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SerialHandshakingHighEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of serial handshaking high events"
+ ::= { event 8 }
+ --1.3.6.1.4.1.3052.10.2.12.8
+
+evShskHighEntry OBJECT-TYPE
+ SYNTAX SerialHandshakingHighEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of serial handshaking high events"
+ INDEX { evShskHighIndex }
+ ::= { evShskHighTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.8.1
+
+evShskHighIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of serial handshaking high events"
+ ::= { evShskHighEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.8.1.1
+
+evShskHighEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enable the serial handshaking high event for this
+ port"
+ ::= { evShskHighEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.8.1.2
+
+evShskHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.8.1.3
+
+evShskHighMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.8.1.4
+
+evShskHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.8.1.5
+
+evShskHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the serial handshaking high event for this
+ port"
+ ::= { evShskHighEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.8.1.6
+
+
+
+--***************************************************************************************
+--No Sensor Event Section 2.12.9
+--***************************************************************************************
+
+evNoSensorTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout (seconds) after which an EventSensor becomes
+ unresponsive that this event is triggered"
+ ::= { evNoSensor 1 }
+ --1.3.6.1.4.1.3052.10.2.12.9.1
+
+evNoSensorActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for no sensor event"
+ ::= { evNoSensor 2 }
+ --1.3.6.1.4.1.3052.10.2.12.9.2
+
+evNoSensorTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for no sensor event"
+ ::= { evNoSensor 3 }
+ --1.3.6.1.4.1.3052.10.2.12.9.3
+
+evNoSensorClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for no sensor event"
+ ::= { evNoSensor 4 }
+ --1.3.6.1.4.1.3052.10.2.12.9.4
+
+
+
+--***************************************************************************************
+--Fuel Sensor Config Section 2.12.11
+--***************************************************************************************
+
+
+fuelSensorGeneralTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes general fuel sensor attributes."
+ ::= { fuelSensor 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1
+
+fsGenEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor general config table."
+ INDEX { fsGenIndex }
+ ::= { fuelSensorGeneralTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1
+
+fsGenIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor general config table."
+ ::= { fsGenEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.1
+
+fsGenName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor name."
+ ::= { fsGenEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.2
+
+fsGenSensorType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of fuel sensor in use; NONE disables the fuel sensor."
+ ::= { fsGenEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.3
+
+fsGenDistanceUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance units in use when setting and indicating tank dimensions."
+ ::= { fsGenEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.4
+
+fsGenRawValueTop OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input reading corresponding to the SENSOR FULL point."
+ ::= { fsGenEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.5
+
+fsGenTopOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance, in the specified distance unit, between the SENSOR FULL
+ point and the TANK FULL point. The value is positive if the
+ SENSOR FULL point is above the TANK FULL point, and negative if it is
+ below."
+ ::= { fsGenEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.6
+
+fsGenRawValueBottom OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input reading corresponding to the minimum fluid height
+ measurable by the fuel sensor."
+ ::= { fsGenEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.7
+
+fsGenBottomOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance, in the specified distance unit, between the SENSOR EMPTY
+ point and the TANK EMPTY point. The value is positive if the
+ SENSOR EMPTY point is above the TANK EMPTY point, and negative if it
+ is below."
+ ::= { fsGenEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.8
+
+fsGenInputES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which eventsensor contains the analog input associated with this fuel
+ sensor. Allowed values are 200 (for internal ES), or 1-16."
+ ::= { fsGenEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.9
+
+fsGenInputPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which analog input point, on the specified eventsensor, that is
+ associated with the fuel sensor."
+ ::= { fsGenEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.10
+
+fsGenFilterAveraging OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor filter averaging factor."
+ ::= { fsGenEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.11
+
+fsGenSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting enable."
+ ::= { fsGenEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.12
+
+fsGenSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting threshold (floating point value)."
+ ::= { fsGenEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.13
+
+fsGenSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting limit."
+ ::= { fsGenEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.14
+
+fsGenSysrepPackage OBJECT-TYPE
+ SYNTAX Integer32 (0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting package number."
+ ::= { fsGenEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.15
+
+fsGenGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor ASM profile type."
+ ::= { fsGenEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.16
+
+fsGenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor enable."
+ ::= { fsGenEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.17
+
+fsGenFuelType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of fuel being measured: DIESEL, PROPANE,
+ NATURAL GAS, HYDROGEN, GASOLINE, OTHER."
+ ::= { fsGenEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.12.11.1.1.18
+
+fuelSensorTankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigTank
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes tank-specific fuel sensor attributes."
+ ::= { fuelSensor 2 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2
+
+fsTankEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigTank
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor tank config table."
+ INDEX { fsTankIndex }
+ ::= { fuelSensorTankTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2.1
+
+fsTankIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor tank config table."
+ ::= { fsTankEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2.1.1
+
+fsTankHeight OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Height of the tank, from the TANK EMPTY point to the TANK FULL point,
+ in the specified distance unit (i.e. TANK HEIGHT). This is a
+ floating point value."
+ ::= { fsTankEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2.1.2
+
+fsTankDimA OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tank dimension measurement A for certain tank profiles. For
+ HORIZ OVAL, this is the length of the straight section. This is a
+ floating point value."
+ ::= { fsTankEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2.1.3
+
+fsTankDimB OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tank dimension measurement B for certain tank profiles. For
+ HORIZ OVAL, this is the radius of the curved section. This is a
+ floating point value."
+ ::= { fsTankEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2.1.4
+
+fsTankVolume OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How many volume units the tank contains, when full. This is a
+ floating point value."
+ ::= { fsTankEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2.1.5
+
+fsTankVolumeUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of the unit representing fluid volume in the tank. This is only
+ used for display purposes; it does not affect the volume calculation."
+ ::= { fsTankEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2.1.6
+
+fsTankShape OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The shape of the fuel tank. A value of LINEAR produces a fluid
+ volume reading that is directly proportional to fluid height. The
+ HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to
+ calculate the volume. The CUSTOM setting uses a strapping table that
+ must be configured as well (see fuelSensorCustomTankTable)."
+ ::= { fsTankEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.11.2.1.7
+
+
+fuelSensorCustomTankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigCustomTankStrapping
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes the custom tank strapping table. Each fuel
+ sensor has a table of height/volume pairs in service only when the tank
+ shape (fsTankShape) in CUSTOM. This allows the unit to calculate
+ volumes for nonstandard tank shapes, to the degree that accurate
+ height/volume measurements can be configured. This SNMP table has two
+ indexes: the first for which fuel sensor and the second for which
+ height/volume pair."
+ ::= { fuelSensor 3 }
+ --1.3.6.1.4.1.3052.10.2.12.11.3
+
+fsCustomTankEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigCustomTankStrapping
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor custom tank config table."
+ INDEX { fsCustomTankIndexFS, fsCustomTankIndexDatum }
+ ::= { fuelSensorCustomTankTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.3.1
+
+fsCustomTankIndexFS OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor tank config table. This is the
+ first of two indexes for this SNMP table."
+ ::= { fsCustomTankEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.3.1.1
+
+fsCustomTankIndexDatum OBJECT-TYPE
+ SYNTAX Integer32 (1..32)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which hight/volume pair: there are 32 pairs per fuel sensor. This is
+ the second of two indexes for this SNMP table."
+ ::= { fsCustomTankEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.11.3.1.2
+
+fsCustomTankHeight OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Height of custom tank height/volume pair. This is a floating point
+ value."
+ ::= { fsCustomTankEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.11.3.1.3
+
+fsCustomTankVolume OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volume of custom tank height/volume pair. This is a floating point
+ value."
+ ::= { fsCustomTankEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.11.3.1.4
+
+
+fuelSensorVolumeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigVolume
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes volume-event-specific fuel sensor attributes."
+ ::= { fuelSensor 4 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4
+
+fsVolumeEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigVolume
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor volume event config table."
+ INDEX { fsVolumeIndex }
+ ::= { fuelSensorVolumeTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1
+
+fsVolumeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor volume event config table."
+ ::= { fsVolumeEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.1
+
+fsVolumeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable fuel sensor volume events."
+ ::= { fsVolumeEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.2
+
+fsVolumeDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor deadband (hysteresis). This is a floating point value."
+ ::= { fsVolumeEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.3
+
+fsVolumeVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold value. This is a
+ floating point value."
+ ::= { fsVolumeEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.4
+
+fsVolumeVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold actions."
+ ::= { fsVolumeEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.5
+
+fsVolumeVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold trap number."
+ ::= { fsVolumeEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.6
+
+fsVolumeVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold class (severity)."
+ ::= { fsVolumeEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.7
+
+fsVolumeHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold value. This is a floating
+ point value."
+ ::= { fsVolumeEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.8
+
+fsVolumeHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold actions."
+ ::= { fsVolumeEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.9
+
+fsVolumeHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold trap number."
+ ::= { fsVolumeEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.10
+
+fsVolumeHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold class (severity)."
+ ::= { fsVolumeEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.11
+
+fsVolumeNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal actions."
+ ::= { fsVolumeEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.12
+
+fsVolumeNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal trap number."
+ ::= { fsVolumeEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.13
+
+fsVolumeNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal class (severity)."
+ ::= { fsVolumeEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.14
+
+fsVolumeLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold value. This is a floating
+ point value."
+ ::= { fsVolumeEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.15
+
+fsVolumeLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold actions."
+ ::= { fsVolumeEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.16
+
+fsVolumeLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold trap number."
+ ::= { fsVolumeEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.17
+
+fsVolumeLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold class (severity)."
+ ::= { fsVolumeEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.18
+
+fsVolumeVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold value. This is a
+ floating point value."
+ ::= { fsVolumeEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.19
+
+fsVolumeVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold actions."
+ ::= { fsVolumeEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.20
+
+fsVolumeVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold trap number."
+ ::= { fsVolumeEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.21
+
+fsVolumeVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold class (severity)."
+ ::= { fsVolumeEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.12.11.4.1.22
+
+
+
+fuelSensorDisconnectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes disconnect-event-specific fuel sensor attributes."
+ ::= { fuelSensor 5 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5
+
+fsDiscEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor disconnect event config table."
+ INDEX { fsDiscIndex }
+ ::= { fuelSensorDisconnectTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1
+
+fsDiscIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor disconnect event config table."
+ ::= { fsDiscEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.1
+
+fsDiscEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event enable."
+ ::= { fsDiscEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.2
+
+fsDiscHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High end of input value range when fuel sensor is disconnected. This
+ is in the units of the analog input value."
+ ::= { fsDiscEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.3
+
+fsDiscLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low end of input value range when fuel sensor is disconnected. This
+ is in the units of the analog input value."
+ ::= { fsDiscEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.4
+
+fsDiscActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event actions."
+ ::= { fsDiscEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.5
+
+fsDiscTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (515..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event trap number."
+ ::= { fsDiscEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.6
+
+fsDiscClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event class (severity)."
+ ::= { fsDiscEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.7
+
+fsDiscNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal actions."
+ ::= { fsDiscEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.8
+
+fsDiscNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (515..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal trap number."
+ ::= { fsDiscEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.9
+
+fsDiscNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal class (severity)."
+ ::= { fsDiscEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.11.5.1.10
+
+
+fuelSensorSuddenChangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigSuddenChange
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes sudden-change-event-specific fuel sensor
+ attributes."
+ ::= { fuelSensor 6 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6
+
+fsSuddenChangeEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigSuddenChange
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor sudden change event config table."
+ INDEX { fsSuddenChangeIndex }
+ ::= { fuelSensorSuddenChangeTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6.1
+
+fsSuddenChangeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor sudden change event
+ config table."
+ ::= { fsSuddenChangeEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6.1.1
+
+fsSuddenChangeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume sudden change event enable."
+ ::= { fsSuddenChangeEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6.1.2
+
+fsSuddenChangeTime OBJECT-TYPE
+ SYNTAX Integer32 (5..360)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume sudden change event time (minutes): what duration defines
+ 'sudden'."
+ ::= { fsSuddenChangeEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6.1.3
+
+fsSuddenChangeAmplitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume sudden change event amplitude: what amount (in fuel
+ volume units) over the duration (fsSuddenChangeTime) defines enough
+ change."
+ ::= { fsSuddenChangeEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6.1.4
+
+fsSuddenChangeActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume sudden change event actions."
+ ::= { fsSuddenChangeEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6.1.5
+
+fsSuddenChangeTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (527..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume sudden change event trap number."
+ ::= { fsSuddenChangeEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6.1.6
+
+fsSuddenChangeClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume sudden change event class (severity)."
+ ::= { fsSuddenChangeEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.11.6.1.7
+
+
+fuelSensorSlowChangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigSlowChange
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes slow-change-event-specific fuel sensor attributes."
+ ::= { fuelSensor 7 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7
+
+fsSlowChangeEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigSlowChange
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor slow change event config table."
+ INDEX { fsSlowChangeIndex }
+ ::= { fuelSensorSlowChangeTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7.1
+
+fsSlowChangeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor slow change event
+ config table."
+ ::= { fsSlowChangeEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7.1.1
+
+fsSlowChangeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume slow change event enable."
+ ::= { fsSlowChangeEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7.1.2
+
+fsSlowChangeTime OBJECT-TYPE
+ SYNTAX Integer32 (1..168)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume slow change event time (minutes): what duration defines
+ 'slow'."
+ ::= { fsSlowChangeEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7.1.3
+
+fsSlowChangeAmplitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume slow change event amplitude: what amount (in fuel volume
+ units) over the duration (fsSlowChangeTime) defines enough change."
+ ::= { fsSlowChangeEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7.1.4
+
+fsSlowChangeActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume slow change event actions."
+ ::= { fsSlowChangeEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7.1.5
+
+fsSlowChangeTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (528..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume slow change event trap number."
+ ::= { fsSlowChangeEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7.1.6
+
+fsSlowChangeClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel volume slow change event class (severity)."
+ ::= { fsSlowChangeEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.11.7.1.7
+
+
+--***************************************************************************************
+--AC Power Monitor Config Section 2.12.12
+--***************************************************************************************
+
+acpmGeneralTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes general AC power monitor attributes."
+ ::= { acPowerMonitor 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1
+
+acpmGenEntry OBJECT-TYPE
+ SYNTAX ACPMConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor general config table."
+ INDEX { acpmGenIndex }
+ ::= { acpmGeneralTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1
+
+acpmGenIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor general config table."
+ ::= { acpmGenEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.1
+
+acpmGenDevice OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Model of the AC power monitor device. The unit needs this setting to
+ know which registers to poll for the various data items, among other
+ things."
+ ::= { acpmGenEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.2
+
+acpmGenName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for the AC power monitor device."
+ ::= { acpmGenEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.3
+
+acpmGenAddress OBJECT-TYPE
+ SYNTAX Integer32 (1..247)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modbus address of the AC power monitor device."
+ ::= { acpmGenEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.4
+
+acpmGenPtRatio OBJECT-TYPE
+ SYNTAX Integer32 (1..10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ratio of secondary turns to primary turns on potential transformers
+ (PT)."
+ ::= { acpmGenEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.5
+
+acpmGenCtRatio OBJECT-TYPE
+ SYNTAX Integer32 (1..10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ratio of secondary turns to primary turns on current transformers
+ (CT)."
+ ::= { acpmGenEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.6
+
+acpmGenPowerType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of power being monitored."
+ ::= { acpmGenEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.7
+
+acpmGenSysrepPackage OBJECT-TYPE
+ SYNTAX Integer32 (0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting package number."
+ ::= { acpmGenEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.8
+
+acpmGenGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ASM profile group."
+ ::= { acpmGenEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.9
+
+acpmGenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "AC power monitor enable."
+ ::= { acpmGenEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.12.1.1.10
+
+
+acpmAvgVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigAvgVoltage
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor average voltage attributes."
+ ::= { acPowerMonitor 2 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2
+
+acpmAvgVoltageEntry OBJECT-TYPE
+ SYNTAX ACPMConfigAvgVoltage
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor average voltage config table."
+ INDEX { acpmAvgVoltageIndex }
+ ::= { acpmAvgVoltageTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1
+
+acpmAvgVoltageIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor average voltage config
+ table."
+ ::= { acpmAvgVoltageEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.1
+
+acpmAvgVoltageEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor average voltage events."
+ ::= { acpmAvgVoltageEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.2
+
+acpmAvgVoltageDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for average voltage event. This is a floating
+ point value."
+ ::= { acpmAvgVoltageEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.3
+
+acpmAvgVoltageVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.4
+
+acpmAvgVoltageVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmAvgVoltageEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.5
+
+acpmAvgVoltageVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmAvgVoltageEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.6
+
+acpmAvgVoltageVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmAvgVoltageEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.7
+
+acpmAvgVoltageHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.8
+
+acpmAvgVoltageHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmAvgVoltageEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.9
+
+acpmAvgVoltageHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmAvgVoltageEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.10
+
+acpmAvgVoltageHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmAvgVoltageEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.11
+
+acpmAvgVoltageNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmAvgVoltageEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.12
+
+acpmAvgVoltageNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmAvgVoltageEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.13
+
+acpmAvgVoltageNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmAvgVoltageEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.14
+
+acpmAvgVoltageLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.15
+
+acpmAvgVoltageLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmAvgVoltageEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.16
+
+acpmAvgVoltageLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmAvgVoltageEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.17
+
+acpmAvgVoltageLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmAvgVoltageEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.18
+
+acpmAvgVoltageVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.19
+
+acpmAvgVoltageVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmAvgVoltageEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.20
+
+acpmAvgVoltageVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmAvgVoltageEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.21
+
+acpmAvgVoltageVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmAvgVoltageEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.22
+
+acpmAvgVoltageSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for average voltage telemetry."
+ ::= { acpmAvgVoltageEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.23
+
+acpmAvgVoltageSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for average voltage telemetry. This is a
+ floating point value."
+ ::= { acpmAvgVoltageEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.24
+
+acpmAvgVoltageSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for average voltage telemetry."
+ ::= { acpmAvgVoltageEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.12.12.2.1.25
+
+
+acpmAvgCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigAvgCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor average current attributes."
+ ::= { acPowerMonitor 3 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3
+
+acpmAvgCurrentEntry OBJECT-TYPE
+ SYNTAX ACPMConfigAvgCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor average current config table."
+ INDEX { acpmAvgCurrentIndex }
+ ::= { acpmAvgCurrentTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1
+
+acpmAvgCurrentIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor average current config
+ table."
+ ::= { acpmAvgCurrentEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.1
+
+acpmAvgCurrentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor average current events."
+ ::= { acpmAvgCurrentEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.2
+
+acpmAvgCurrentDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for average current event. This is a floating
+ point value."
+ ::= { acpmAvgCurrentEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.3
+
+acpmAvgCurrentVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.4
+
+acpmAvgCurrentVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmAvgCurrentEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.5
+
+acpmAvgCurrentVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmAvgCurrentEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.6
+
+acpmAvgCurrentVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmAvgCurrentEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.7
+
+acpmAvgCurrentHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.8
+
+acpmAvgCurrentHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmAvgCurrentEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.9
+
+acpmAvgCurrentHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmAvgCurrentEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.10
+
+acpmAvgCurrentHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmAvgCurrentEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.11
+
+acpmAvgCurrentNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmAvgCurrentEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.12
+
+acpmAvgCurrentNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmAvgCurrentEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.13
+
+acpmAvgCurrentNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmAvgCurrentEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.14
+
+acpmAvgCurrentLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.15
+
+acpmAvgCurrentLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmAvgCurrentEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.16
+
+acpmAvgCurrentLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmAvgCurrentEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.17
+
+acpmAvgCurrentLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmAvgCurrentEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.18
+
+acpmAvgCurrentVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.19
+
+acpmAvgCurrentVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmAvgCurrentEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.20
+
+acpmAvgCurrentVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmAvgCurrentEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.21
+
+acpmAvgCurrentVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmAvgCurrentEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.22
+
+acpmAvgCurrentSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for average current telemetry."
+ ::= { acpmAvgCurrentEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.23
+
+acpmAvgCurrentSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for average current telemetry. This is
+ a floating point value."
+ ::= { acpmAvgCurrentEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.24
+
+acpmAvgCurrentSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for average current telemetry."
+ ::= { acpmAvgCurrentEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.12.12.3.1.25
+
+
+acpmFreqTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigFreq
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor frequency attributes."
+ ::= { acPowerMonitor 4 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4
+
+acpmFreqEntry OBJECT-TYPE
+ SYNTAX ACPMConfigFreq
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor frequency config table."
+ INDEX { acpmFreqIndex }
+ ::= { acpmFreqTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1
+
+acpmFreqIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor frequency config table."
+ ::= { acpmFreqEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.1
+
+acpmFreqEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor frequency events."
+ ::= { acpmFreqEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.2
+
+acpmFreqDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for frequency event. This is a floating point
+ value."
+ ::= { acpmFreqEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.3
+
+acpmFreqVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.4
+
+acpmFreqVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmFreqEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.5
+
+acpmFreqVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmFreqEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.6
+
+acpmFreqVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmFreqEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.7
+
+acpmFreqHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.8
+
+acpmFreqHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmFreqEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.9
+
+acpmFreqHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmFreqEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.10
+
+acpmFreqHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmFreqEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.11
+
+acpmFreqNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmFreqEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.12
+
+acpmFreqNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmFreqEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.13
+
+acpmFreqNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmFreqEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.14
+
+acpmFreqLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.15
+
+acpmFreqLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmFreqEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.16
+
+acpmFreqLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmFreqEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.17
+
+acpmFreqLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmFreqEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.18
+
+acpmFreqVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.19
+
+acpmFreqVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmFreqEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.20
+
+acpmFreqVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmFreqEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.21
+
+acpmFreqVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmFreqEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.22
+
+acpmFreqSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for frequency telemetry."
+ ::= { acpmFreqEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.23
+
+acpmFreqSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for frequency telemetry. This is a
+ floating point value."
+ ::= { acpmFreqEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.24
+
+acpmFreqSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for frequency telemetry."
+ ::= { acpmFreqEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.12.12.4.1.25
+
+
+acpmTotalRealPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigTRP
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor total real power attributes."
+ ::= { acPowerMonitor 5 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5
+
+acpmTRPEntry OBJECT-TYPE
+ SYNTAX ACPMConfigTRP
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor total real power config table."
+ INDEX { acpmTRPIndex }
+ ::= { acpmTotalRealPowerTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1
+
+acpmTRPIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor total real power
+ config table."
+ ::= { acpmTRPEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.1
+
+acpmTRPEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor total real power events."
+ ::= { acpmTRPEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.2
+
+acpmTRPDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for total real power event. This is a
+ floating point value."
+ ::= { acpmTRPEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.3
+
+acpmTRPVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.4
+
+acpmTRPVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmTRPEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.5
+
+acpmTRPVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmTRPEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.6
+
+acpmTRPVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmTRPEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.7
+
+acpmTRPHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.8
+
+acpmTRPHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmTRPEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.9
+
+acpmTRPHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmTRPEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.10
+
+acpmTRPHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmTRPEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.11
+
+acpmTRPNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmTRPEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.12
+
+acpmTRPNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmTRPEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.13
+
+acpmTRPNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmTRPEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.14
+
+acpmTRPLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.15
+
+acpmTRPLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmTRPEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.16
+
+acpmTRPLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmTRPEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.17
+
+acpmTRPLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmTRPEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.18
+
+acpmTRPVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.19
+
+acpmTRPVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmTRPEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.20
+
+acpmTRPVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmTRPEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.21
+
+acpmTRPVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmTRPEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.22
+
+acpmTRPSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for total real power telemetry."
+ ::= { acpmTRPEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.23
+
+acpmTRPSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for total real power telemetry. This is a
+ floating point value."
+ ::= { acpmTRPEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.24
+
+acpmTRPSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for total real power telemetry."
+ ::= { acpmTRPEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.12.12.5.1.25
+
+
+acpmDisconnectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor device disconnect event
+ attributes."
+ ::= { acPowerMonitor 6 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6
+
+acpmDisconnectEntry OBJECT-TYPE
+ SYNTAX ACPMConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor device disconnect event config table."
+ INDEX { acpmDisconnectIndex }
+ ::= { acpmDisconnectTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1
+
+acpmDisconnectIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor device disconnect event
+ config table."
+ ::= { acpmDisconnectEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1.1
+
+acpmDisconnectEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor device disconnect event."
+ ::= { acpmDisconnectEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1.2
+
+acpmDisconnectActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for disconnect event."
+ ::= { acpmDisconnectEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1.3
+
+acpmDisconnectTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (524..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for disconnect event."
+ ::= { acpmDisconnectEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1.4
+
+acpmDisconnectClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for disconnect event."
+ ::= { acpmDisconnectEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1.5
+
+acpmDisconnectNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1.6
+
+acpmDisconnectNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (524..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1.7
+
+acpmDisconnectNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.12.6.1.8
+
+acpmTotalPowerFactorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigTotalPowerFactor
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor device total power factor
+ event attributes."
+ ::= { acPowerMonitor 7 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7
+
+acpmTPFEntry OBJECT-TYPE
+ SYNTAX ACPMConfigTotalPowerFactor
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor device total power factor event config
+ table."
+ INDEX { acpmTPFIndex }
+ ::= { acpmTotalPowerFactorTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1
+
+acpmTPFIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor device disconnect
+ event config table."
+ ::= { acpmTPFEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.1
+
+acpmTPFEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor device disconnect event."
+ ::= { acpmTPFEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.2
+
+acpmTPFDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis)."
+ ::= { acpmTPFEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.3
+
+acpmTPFNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal actions."
+ ::= { acpmTPFEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.4
+
+acpmTPFNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal trap number."
+ ::= { acpmTPFEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.5
+
+acpmTPFNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal class."
+ ::= { acpmTPFEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.6
+
+acpmTPFLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold."
+ ::= { acpmTPFEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.7
+
+acpmTPFLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low actions."
+ ::= { acpmTPFEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.8
+
+acpmTPFLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low trap number."
+ ::= { acpmTPFEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.9
+
+acpmTPFLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low class."
+ ::= { acpmTPFEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.10
+
+acpmTPFVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low threshold."
+ ::= { acpmTPFEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.11
+
+acpmTPFVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low actions."
+ ::= { acpmTPFEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.12
+
+acpmTPFVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low trap number."
+ ::= { acpmTPFEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.13
+
+acpmTPFVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low class."
+ ::= { acpmTPFEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.14
+
+acpmTPFSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable."
+ ::= { acpmTPFEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.15
+
+acpmTPFSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold."
+ ::= { acpmTPFEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.16
+
+acpmTPFSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit."
+ ::= { acpmTPFEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.12.7.1.17
+
+
+
+--***************************************************************************************
+--Reset Event Section 2.12.16
+--***************************************************************************************
+
+
+evResetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable reset event. This event is triggered when the unit
+ finishes booting."
+ ::= { evReset 1 }
+ --1.3.6.1.4.1.3052.10.2.12.16.1
+
+evResetDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..3600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds to wait after unit finishes booting before triggering
+ the reset event."
+ ::= { evReset 2 }
+ --1.3.6.1.4.1.3052.10.2.12.16.2
+
+evResetActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for reset event."
+ ::= { evReset 3 }
+ --1.3.6.1.4.1.3052.10.2.12.16.3
+
+evResetMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for reset event."
+ ::= { evReset 4 }
+ --1.3.6.1.4.1.3052.10.2.12.16.4
+
+evResetTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (543..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for reset event."
+ ::= { evReset 5 }
+ --1.3.6.1.4.1.3052.10.2.12.16.5
+
+evResetClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for reset event."
+ ::= { evReset 6 }
+ --1.3.6.1.4.1.3052.10.2.12.16.6
+
+
+--***************************************************************************************
+--Global Event Section 2.12.18
+--***************************************************************************************
+
+evGlobalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Global event actions."
+ ::= { evGlobal 2 }
+ --1.3.6.1.4.1.3052.10.2.12.18.2
+
+evGlobalTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (0..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Global trap number."
+ ::= { evGlobal 3 }
+ --1.3.6.1.4.1.3052.10.2.12.18.3
+
+
+--***************************************************************************************
+--HVAC Configuration Section 2.12.19
+--***************************************************************************************
+--***************************************************************************************
+--BARD HVAC Configuration Section 2.12.19.2
+--***************************************************************************************
+
+evHVACBardIPAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address of the Bard HVAC controller."
+ ::= { evHVACBardLocal 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.1
+
+evHVACBardPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port of the Bard HVAC controller interface."
+ ::= { evHVACBardLocal 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.2
+
+evHVACBardTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait for a response from the Bard HVAC controller."
+ ::= { evHVACBardLocal 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.3
+
+evHVACBardXMLStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "XML status page of the Bard HVAC controller."
+ ::= { evHVACBardLocal 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.4
+
+evHVACBardXMLSettings OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "XML settings page of the Bard HVAC controller."
+ ::= { evHVACBardLocal 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.5
+
+evHVACBardWebSettingsHTML OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Web settings page of the Bard HVAC controller."
+ ::= { evHVACBardLocal 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.6
+
+evHVACBardAlarmEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable the Bard HVAC Alarm event."
+ ::= { evHVACBardAlarm 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.1
+
+evHVACBardAlarmActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the Bard HVAC Alarm event."
+ ::= { evHVACBardAlarm 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.2
+
+evHVACBardAlarmTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the Bard HVAC Alarm event."
+ ::= { evHVACBardAlarm 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.3
+
+evHVACBardAlarmClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the Bard HVAC Alarm event."
+ ::= { evHVACBardAlarm 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.4
+
+evHVACBardAlarmNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the Bard HVAC Alarm Return to Normal event."
+ ::= { evHVACBardAlarm 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.5
+
+evHVACBardAlarmNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the Bard HVAC Alarm Return to Normal event."
+ ::= { evHVACBardAlarm 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.6
+
+evHVACBardAlarmNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the Bard HVAC Alarm Return to Normal event."
+ ::= { evHVACBardAlarm 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.7.7
+
+evHVACBardReset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to any value to reset the Bard HVAC controller. Always reads zero."
+ ::= { evHVACBardLocal 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.8
+
+evHVACBardDefault OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to any value to restore default settings on the Bard HVAC controller. Always reads zero."
+ ::= { evHVACBardLocal 9 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.1.9
+
+evHVACBardTempScale OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Scale used, Celsius or Fahrenheit (C or F)."
+ ::= { evHVACBardSynchronized 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.1
+
+evHVACBardCoolThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Cooling threshold to turn on HVAC cooling elements (economizer/compressor)."
+ ::= { evHVACBardSynchronized 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.2
+
+evHVACBardCoolThresholdState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.3
+
+evHVACBardHeatThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Heating threshold to turn on HVAC heating elements (economizer/compressor)."
+ ::= { evHVACBardSynchronized 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.4
+
+evHVACBardHeatDiff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Heating differential to turn on HVAC heating elements. The heating threshold
+ is calculated by subtracting this number from the current cool threshold."
+ ::= { evHVACBardSynchronized 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.5
+
+evHVACBardHeatDiffState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.6
+
+evHVACBardBlower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Continuous blower operation enable."
+ ::= { evHVACBardSynchronized 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.7
+
+evHVACBardBlowerState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.8
+
+evHVACBardAlternate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alternate lead-lag sequence for the economizer."
+ ::= { evHVACBardSynchronized 9 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.9
+
+evHVACBardAlternateState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 10 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.10
+
+evHVACBardChangeover OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Lead-lag changeover time in days."
+ ::= { evHVACBardSynchronized 11 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.11
+
+evHVACBardChangeoverState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 12 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.12
+
+evHVACBardBlowDiff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable to run blowers if two sensors have a difference of 5 F or greater."
+ ::= { evHVACBardSynchronized 13 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.13
+
+evHVACBardBlowDiffState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 14 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.14
+
+evHVACBardOffDelay OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "3 minute lead/4 minute lag unit off delay enable."
+ ::= { evHVACBardSynchronized 15 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.15
+
+evHVACBardOffDelayState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 16 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.16
+
+evHVACBardRunMin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run the compressor for at least 3 minutes before shutting off enable."
+ ::= { evHVACBardSynchronized 17 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.17
+
+evHVACBardRunMinState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 18 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.18
+
+evHVACBardStage1Diff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Temperature differential between stages 1 and 2."
+ ::= { evHVACBardDiff 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.1
+
+evHVACBardStage1DiffState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardDiff 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.2
+
+evHVACBardStage2Diff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Temperature differential between stages 2 and 3."
+ ::= { evHVACBardDiff 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.3
+
+evHVACBardStage2DiffState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardDiff 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.4
+
+evHVACBardStage3Diff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Temperature differential between stages 3 and 4."
+ ::= { evHVACBardDiff 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.5
+
+evHVACBardStage3DiffState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardDiff 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.19.6
+
+evHVACBardCoolDisableDb OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Cooling disable deadband."
+ ::= { evHVACBardSynchronized 20 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.20
+
+evHVACBardCoolDisableDbState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 21 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.21
+
+evHVACBardCoolEnableDb OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Cooling enable deadband."
+ ::= { evHVACBardSynchronized 22 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.22
+
+evHVACBardCoolEnableDbState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 23 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.23
+
+evHVACBardHeatDb OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Heating deadband."
+ ::= { evHVACBardSynchronized 24 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.24
+
+evHVACBardHeatDbState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 25 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.25
+
+evHVACBardHeatPump OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Heat pump logic enable."
+ ::= { evHVACBardSynchronized 26 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.26
+
+evHVACBardHeatPumpState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 27 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.27
+
+evHVACBardCompressors OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 28 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.28
+
+evHVACBardCompressorsState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 29 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.29
+
+evHVACBardEconomizer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 30 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.30
+
+evHVACBardEconomizerState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 31 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.31
+
+evHVACBardTempLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low alarm for temperature."
+ ::= { evHVACBardTemp 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.1
+
+evHVACBardTempLowValueState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardTemp 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.2
+
+evHVACBardTempHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High alarm for temperature."
+ ::= { evHVACBardTemp 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.3
+
+evHVACBardTempHighValueState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardTemp 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.4
+
+evHVACBardTempVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high alarm for temperature."
+ ::= { evHVACBardTemp 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.5
+
+evHVACBardTempVHighValueState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardTemp 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.32.6
+
+evHVACBardOverride OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The HVAC controller override."
+ ::= { evHVACBardSynchronized 33 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.33
+
+evHVACBardOverrideState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 34 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.34
+
+evHVACBardLock OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable the external controller lock."
+ ::= { evHVACBardSynchronized 35 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.35
+
+evHVACBardLockState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 36 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.36
+
+evHVACBardLeadUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which HVAC unit is currently the lead unit."
+ ::= { evHVACBardSynchronized 37 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.37
+
+evHVACBardLeadUnitState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 38 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.38
+
+evHVACBardComfort OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable comfort mode."
+ ::= { evHVACBardSynchronized 39 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.39
+
+evHVACBardComfortState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronization status of previous object: ERROR (with possible description), PENDING, or OK."
+ ::= { evHVACBardSynchronized 40 }
+ --1.3.6.1.4.1.3052.10.2.12.19.2.2.40
+
+
+--***************************************************************************************
+--Asentria HVAC Configuration Section 2.12.19.3
+--***************************************************************************************
+
+evHVACAsentriaSensorListTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HVACAsentriaSensorList
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature/humidity sensor list table"
+ ::= { evHVACAsentria 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.1
+
+evHVACAsentriaSensorListEntry OBJECT-TYPE
+ SYNTAX HVACAsentriaSensorList
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature/humidity sensor list table entry"
+ INDEX { evHVACAsentriaSensorListIndex }
+ ::= { evHVACAsentriaSensorListTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.1.1
+
+evHVACAsentriaSensorListIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Asentria HVAC temperature/humidity sensor"
+ ::= { evHVACAsentriaSensorListEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.1
+
+evHVACAsentriaSensorListES OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature/humidity sensor EventSensor number"
+ ::= { evHVACAsentriaSensorListEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.2
+
+evHVACAsentriaSensorListPT OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature/humidity sensor point"
+ ::= { evHVACAsentriaSensorListEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.3
+
+evHVACAsentriaSensorListType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature/humidity sensor type"
+ ::= { evHVACAsentriaSensorListEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.4
+
+evHVACAsentriaSensorListLoc OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature/humidity sensor location"
+ ::= { evHVACAsentriaSensorListEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.1.1.5
+
+evHVACAsentriaOverride OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC controller override"
+ ::= { evHVACAsentria 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.2
+
+evHVACAsentriaSchedule OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit primary/lead swap schedule"
+ ::= { evHVACAsentria 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.3
+
+evHVACAsentriaPrimary OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC primary/lead unit to operate"
+ ::= { evHVACAsentria 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.4
+
+evHVACAsentriaMethod OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC controller temperature/humidity calculation
+ method"
+ ::= { evHVACAsentria 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.5
+
+evHVACAsentriaAlarmLagNormEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC enable for normal/idle alarm notification on
+ lag unit"
+ ::= { evHVACAsentriaAlarm 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.1
+
+evHVACAsentriaAlarmLagNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC actions to perform for normal/idle alarm
+ notification on lag unit"
+ ::= { evHVACAsentriaAlarm 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.2
+
+evHVACAsentriaAlarmLagNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC trap number for normal/idle alarm notification
+ on lag unit"
+ ::= { evHVACAsentriaAlarm 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.3
+
+evHVACAsentriaAlarmLagNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC alarm class for normal/idle alarm notification
+ on lag unit"
+ ::= { evHVACAsentriaAlarm 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.4
+
+evHVACAsentriaAlarmLagVentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC enable for venting alarm notification on lag
+ unit"
+ ::= { evHVACAsentriaAlarm 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.5
+
+evHVACAsentriaAlarmLagVentActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC actions to perform for venting alarm
+ notification on lag unit"
+ ::= { evHVACAsentriaAlarm 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.6
+
+evHVACAsentriaAlarmLagVentTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC trap number for venting alarm notification on
+ lag unit"
+ ::= { evHVACAsentriaAlarm 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.7
+
+evHVACAsentriaAlarmLagVentClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC alarm class for venting alarm notification on
+ lag unit"
+ ::= { evHVACAsentriaAlarm 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.8
+
+evHVACAsentriaAlarmLagCoolEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC enable for cooling alarm notification on lag
+ unit"
+ ::= { evHVACAsentriaAlarm 9 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.9
+
+evHVACAsentriaAlarmLagCoolActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC actions to perform for cooling alarm
+ notification on lag unit"
+ ::= { evHVACAsentriaAlarm 10 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.10
+
+evHVACAsentriaAlarmLagCoolTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC trap number for cooling alarm notification on
+ lag unit"
+ ::= { evHVACAsentriaAlarm 11 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.11
+
+evHVACAsentriaAlarmLagCoolClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC alarm class for cooling alarm notification on
+ lag unit"
+ ::= { evHVACAsentriaAlarm 12 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.12
+
+evHVACAsentriaAlarmLagHeatEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC enable for heating alarm notification on lag
+ unit"
+ ::= { evHVACAsentriaAlarm 13 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.13
+
+evHVACAsentriaAlarmLagHeatActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC actions to perform for heating alarm
+ notification on lag unit"
+ ::= { evHVACAsentriaAlarm 14 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.14
+
+evHVACAsentriaAlarmLagHeatTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC trap number for heating alarm notification on
+ lag unit"
+ ::= { evHVACAsentriaAlarm 15 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.15
+
+evHVACAsentriaAlarmLagHeatClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC alarm class for heating alarm notification on
+ lag unit"
+ ::= { evHVACAsentriaAlarm 16 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.6.16
+
+evHVACAsentriaFireES OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC fire/smoke alarm EventSensor number"
+ ::= { evHVACAsentriaFire 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7.1
+
+evHVACAsentriaFirePT OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC fire/smoke alarm point number"
+ ::= { evHVACAsentriaFire 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7.2
+
+evHVACAsentriaFireActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC actions to perform for fire/smoke alarm
+ notification"
+ ::= { evHVACAsentriaFire 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7.3
+
+evHVACAsentriaFireTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC trap number for fire/smoke alarm notification"
+ ::= { evHVACAsentriaFire 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7.4
+
+evHVACAsentriaFireClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC alarm class for fire/smoke alarm notification"
+ ::= { evHVACAsentriaFire 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7.5
+
+evHVACAsentriaFireNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC return to normal actions to perform for
+ fire/smoke alarm notification"
+ ::= { evHVACAsentriaFire 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7.6
+
+evHVACAsentriaFireNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC return to normal trap number for fire/smoke
+ alarm notification"
+ ::= { evHVACAsentriaFire 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7.7
+
+evHVACAsentriaFireNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC return to normal class for fire/smoke alarm
+ notification"
+ ::= { evHVACAsentriaFire 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.7.8
+
+evHVACAsentriaUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HVACAsentriaUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit table"
+ ::= { evHVACAsentria 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8
+
+evHVACAsentriaUnitEntry OBJECT-TYPE
+ SYNTAX HVACAsentriaUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit table entry"
+ INDEX { evHVACAsentriaUnitIndex }
+ ::= { evHVACAsentriaUnitTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1
+
+evHVACAsentriaUnitIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Asentria HVAC unit"
+ ::= { evHVACAsentriaUnitEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.1
+
+evHVACAsentriaUnitEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC unit enable"
+ ::= { evHVACAsentriaUnitEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.2
+
+evHVACAsentriaUnitFanRelayES OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EventSensor number of relay to control the fan on Asentria
+ HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.3
+
+evHVACAsentriaUnitFanRelayPT OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Point number of relay to control the fan on Asentria HVAC
+ controller"
+ ::= { evHVACAsentriaUnitEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.4
+
+evHVACAsentriaUnitVentRelayES OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EventSensor number of relay to control the vent on Asentria
+ HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.5
+
+evHVACAsentriaUnitVentRelayPT OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Point number of relay to control the vent on Asentria HVAC
+ controller"
+ ::= { evHVACAsentriaUnitEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.6
+
+evHVACAsentriaUnitTimereset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Resets the time counter for Asentria HVAC unit"
+ ::= { evHVACAsentriaUnitEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.7
+
+evHVACAsentriaSeqTimereset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Resets the time counter for Asentria HVAC sequence number"
+ ::= { evHVACAsentriaUnitEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.8
+
+evHVACAsentriaUnitStage1CoolES OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EventSensor number of relay to control compressor stage 1 on
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.20
+
+evHVACAsentriaUnitStage1CoolPT OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Point number of relay to control compressor stage 1 on
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.21
+
+evHVACAsentriaUnitStage1HeatES OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EventSensor number of relay to control heater stage 1 on
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.22
+
+evHVACAsentriaUnitStage1HeatPT OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Point number of relay to control heater stage 1 on
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.23
+
+evHVACAsentriaUnitStage2CoolES OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EventSensor number of relay to control compressor stage 2 on
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 30 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.30
+
+evHVACAsentriaUnitStage2CoolPT OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Point number of relay to control compressor stage 2 on
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 31 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.31
+
+evHVACAsentriaUnitStage2HeatES OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EventSensor number of relay to control heater stage 2 on
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 32 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.32
+
+evHVACAsentriaUnitStage2HeatPT OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Point number of relay to control heater stage 2 on
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaUnitEntry 33 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.8.1.33
+
+evHVACAsentriaTempScale OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC controller temperature scale"
+ ::= { evHVACAsentriaTemp 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.1
+
+evHVACAsentriaTempCoolThresh OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Temperature above this threshold before cooling via Asentria
+ HVAC controller"
+ ::= { evHVACAsentriaTemp 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.2
+
+evHVACAsentriaTempHeatThresh OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Temperature below this threshold before heating via Asentria
+ HVAC controller"
+ ::= { evHVACAsentriaTemp 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.3
+
+evHVACAsentriaTempEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm enable"
+ ::= { evHVACAsentriaTemp 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.4
+
+evHVACAsentriaTempEventDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event deadband"
+ ::= { evHVACAsentriaTemp 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.5
+
+evHVACAsentriaTempVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event very low value"
+ ::= { evHVACAsentriaTemp 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.6
+
+evHVACAsentriaTempVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event very low actions"
+ ::= { evHVACAsentriaTemp 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.7
+
+evHVACAsentriaTempVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event very low trap number"
+ ::= { evHVACAsentriaTemp 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.8
+
+evHVACAsentriaTempVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event very low class"
+ ::= { evHVACAsentriaTemp 9 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.9
+
+evHVACAsentriaTempLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event low value"
+ ::= { evHVACAsentriaTemp 10 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.10
+
+evHVACAsentriaTempLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event low actions"
+ ::= { evHVACAsentriaTemp 11 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.11
+
+evHVACAsentriaTempLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event low trap number"
+ ::= { evHVACAsentriaTemp 12 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.12
+
+evHVACAsentriaTempLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event low class"
+ ::= { evHVACAsentriaTemp 13 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.13
+
+evHVACAsentriaTempNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event return to normal
+ actions"
+ ::= { evHVACAsentriaTemp 14 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.14
+
+evHVACAsentriaTempNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event return to normal trap
+ number"
+ ::= { evHVACAsentriaTemp 15 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.15
+
+evHVACAsentriaTempNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event return to normal class"
+ ::= { evHVACAsentriaTemp 16 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.16
+
+evHVACAsentriaTempHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event high value"
+ ::= { evHVACAsentriaTemp 17 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.17
+
+evHVACAsentriaTempHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event high actions"
+ ::= { evHVACAsentriaTemp 18 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.18
+
+evHVACAsentriaTempHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event high trap number"
+ ::= { evHVACAsentriaTemp 19 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.19
+
+evHVACAsentriaTempHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event high class"
+ ::= { evHVACAsentriaTemp 20 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.20
+
+evHVACAsentriaTempVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event very high value"
+ ::= { evHVACAsentriaTemp 21 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.21
+
+evHVACAsentriaTempVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event very high actions"
+ ::= { evHVACAsentriaTemp 22 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.22
+
+evHVACAsentriaTempVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event very high trap number"
+ ::= { evHVACAsentriaTemp 23 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.23
+
+evHVACAsentriaTempVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature alarm event very high class"
+ ::= { evHVACAsentriaTemp 24 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.24
+
+evHVACAsentriaTempDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature deadband before stopping current
+ state"
+ ::= { evHVACAsentriaTemp 25 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.25
+
+evHVACAsentriaTempDifference OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC temperature step before changing states"
+ ::= { evHVACAsentriaTemp 26 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.26
+
+evHVACAsentriaHumidInThresh OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Humidity above this threshold before cooling via Asentria
+ HVAC controller"
+ ::= { evHVACAsentriaHumid 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.2
+
+evHVACAsentriaHumidOutThresh OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Humidity above this threshold before not allowing venting via
+ Asentria HVAC controller"
+ ::= { evHVACAsentriaHumid 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.3
+
+evHVACAsentriaHumidEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm enable"
+ ::= { evHVACAsentriaHumid 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.4
+
+evHVACAsentriaHumidEventDeadband OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event deadband"
+ ::= { evHVACAsentriaHumid 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.5
+
+evHVACAsentriaHumidVLowValue OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event very low value"
+ ::= { evHVACAsentriaHumid 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.6
+
+evHVACAsentriaHumidVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event very low actions"
+ ::= { evHVACAsentriaHumid 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.7
+
+evHVACAsentriaHumidVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event very low trap number"
+ ::= { evHVACAsentriaHumid 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.8
+
+evHVACAsentriaHumidVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event very low class"
+ ::= { evHVACAsentriaHumid 9 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.9
+
+evHVACAsentriaHumidLowValue OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event low value"
+ ::= { evHVACAsentriaHumid 10 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.10
+
+evHVACAsentriaHumidLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event low actions"
+ ::= { evHVACAsentriaHumid 11 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.11
+
+evHVACAsentriaHumidLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event low trap number"
+ ::= { evHVACAsentriaHumid 12 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.12
+
+evHVACAsentriaHumidLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event low class"
+ ::= { evHVACAsentriaHumid 13 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.13
+
+evHVACAsentriaHumidNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event return to normal
+ actions"
+ ::= { evHVACAsentriaHumid 14 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.14
+
+evHVACAsentriaHumidNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event return to normal trap
+ number"
+ ::= { evHVACAsentriaHumid 15 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.15
+
+evHVACAsentriaHumidNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event return to normal class"
+ ::= { evHVACAsentriaHumid 16 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.16
+
+evHVACAsentriaHumidHighValue OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event high value"
+ ::= { evHVACAsentriaHumid 17 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.17
+
+evHVACAsentriaHumidHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event high actions"
+ ::= { evHVACAsentriaHumid 18 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.18
+
+evHVACAsentriaHumidHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event high trap number"
+ ::= { evHVACAsentriaHumid 19 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.19
+
+evHVACAsentriaHumidHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event high class"
+ ::= { evHVACAsentriaHumid 20 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.20
+
+evHVACAsentriaHumidVHighValue OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event very high value"
+ ::= { evHVACAsentriaHumid 21 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.21
+
+evHVACAsentriaHumidVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event very high actions"
+ ::= { evHVACAsentriaHumid 22 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.22
+
+evHVACAsentriaHumidVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (545..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event very high trap number"
+ ::= { evHVACAsentriaHumid 23 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.23
+
+evHVACAsentriaHumidVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity alarm event very high class"
+ ::= { evHVACAsentriaHumid 24 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.24
+
+evHVACAsentriaHumidDeadband OBJECT-TYPE
+ SYNTAX Integer32 (1..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity deadband before stopping current
+ state"
+ ::= { evHVACAsentriaHumid 25 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.25
+
+evHVACAsentriaHumidDifference OBJECT-TYPE
+ SYNTAX Integer32 (1..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Asentria HVAC humidity step before changing states"
+ ::= { evHVACAsentriaHumid 26 }
+ --1.3.6.1.4.1.3052.10.2.12.19.3.9.26
+
+
+--***************************************************************************************
+--Airsys HVAC Configuration Section 2.12.19.4
+--***************************************************************************************
+
+evHVACAirsysGeneratorLogic OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC generator logic"
+ ::= { evHVACAirsysGeneral 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.1.1
+
+evHVACAirsysFreeMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC free mode"
+ ::= { evHVACAirsysGeneral 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.1.2
+
+evHVACAirsysRemoteEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC remote control enable"
+ ::= { evHVACAirsysGeneral 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.1.3
+
+evHVACAirsysHVACRotation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC rotate unit lead/lag"
+ ::= { evHVACAirsysGeneral 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.1.4
+
+evHVACAirsysRotationRuntime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC rotation runtime period"
+ ::= { evHVACAirsysGeneral 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.1.5
+
+evHVACAirsysUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HVACAirsysUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit table"
+ ::= { evHVACAirsysAlarm 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1
+
+evHVACAirsysUnitEntry OBJECT-TYPE
+ SYNTAX HVACAirsysUnit
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit table entry"
+ INDEX { evHVACAirsysUnitIndex }
+ ::= { evHVACAirsysUnitTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1
+
+evHVACAirsysUnitIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Airsys HVAC unit"
+ ::= { evHVACAirsysUnitEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.1
+
+evHVACAirsysULowPEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit low pressure alarm enable"
+ ::= { evHVACAirsysUnitEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.2
+
+evHVACAirsysULowPActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for low pressure alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.3
+
+evHVACAirsysULowPTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for low pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.4
+
+evHVACAirsysULowPClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for low pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.5
+
+evHVACAirsysULowPNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ low pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.6
+
+evHVACAirsysULowPNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for low pressure
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.7
+
+evHVACAirsysULowPNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for low pressure alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.8
+
+evHVACAirsysUHighPEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit high pressure alarm enable"
+ ::= { evHVACAirsysUnitEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.9
+
+evHVACAirsysUHighPActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for high pressure alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.10
+
+evHVACAirsysUHighPTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for high pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.11
+
+evHVACAirsysUHighPClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for high pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.12
+
+evHVACAirsysUHighPNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ high pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.13
+
+evHVACAirsysUHighPNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for high pressure
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.14
+
+evHVACAirsysUHighPNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for high pressure alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.15
+
+evHVACAirsysUEvapFanEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit evaporator fan alarm enable"
+ ::= { evHVACAirsysUnitEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.16
+
+evHVACAirsysUEvapFanActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for evaporator fan alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.17
+
+evHVACAirsysUEvapFanTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for evaporator fan alarm notification"
+ ::= { evHVACAirsysUnitEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.18
+
+evHVACAirsysUEvapFanClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for evaporator fan alarm notification"
+ ::= { evHVACAirsysUnitEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.19
+
+evHVACAirsysUEvapFanNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ evaporator fan alarm notification"
+ ::= { evHVACAirsysUnitEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.20
+
+evHVACAirsysUEvapFanNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for evaporator fan
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.21
+
+evHVACAirsysUEvapFanNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for evaporator fan alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.22
+
+evHVACAirsysUDirtyEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit dirty filter alarm enable"
+ ::= { evHVACAirsysUnitEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.23
+
+evHVACAirsysUDirtyActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for dirty filter alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.24
+
+evHVACAirsysUDirtyTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for dirty filter alarm notification"
+ ::= { evHVACAirsysUnitEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.25
+
+evHVACAirsysUDirtyClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for dirty filter alarm notification"
+ ::= { evHVACAirsysUnitEntry 26 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.26
+
+evHVACAirsysUDirtyNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ dirty filter alarm notification"
+ ::= { evHVACAirsysUnitEntry 27 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.27
+
+evHVACAirsysUDirtyNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for dirty filter
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 28 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.28
+
+evHVACAirsysUDirtyNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for dirty filter alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 29 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.29
+
+evHVACAirsysUInProbeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit indoor probe broken alarm enable"
+ ::= { evHVACAirsysUnitEntry 30 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.30
+
+evHVACAirsysUInProbeActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for indoor probe broken
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 31 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.31
+
+evHVACAirsysUInProbeTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for indoor probe broken alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 32 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.32
+
+evHVACAirsysUInProbeClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for indoor probe broken alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 33 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.33
+
+evHVACAirsysUInProbeNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ indoor probe broken alarm notification"
+ ::= { evHVACAirsysUnitEntry 34 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.34
+
+evHVACAirsysUInProbeNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for indoor probe
+ broken alarm notification"
+ ::= { evHVACAirsysUnitEntry 35 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.35
+
+evHVACAirsysUInProbeNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for indoor probe broken
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 36 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.36
+
+evHVACAirsysUDamperEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit high pressure alarm enable"
+ ::= { evHVACAirsysUnitEntry 37 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.37
+
+evHVACAirsysUDamperActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for high pressure alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 38 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.38
+
+evHVACAirsysUDamperTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for high pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 39 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.39
+
+evHVACAirsysUDamperClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for high pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 40 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.40
+
+evHVACAirsysUDamperNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ high pressure alarm notification"
+ ::= { evHVACAirsysUnitEntry 41 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.41
+
+evHVACAirsysUDamperNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for high pressure
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 42 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.42
+
+evHVACAirsysUDamperNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for high pressure alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 43 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.43
+
+evHVACAirsysUSupProbeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit supply probe broken alarm enable"
+ ::= { evHVACAirsysUnitEntry 44 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.44
+
+evHVACAirsysUSupProbeActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for supply probe broken
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 45 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.45
+
+evHVACAirsysUSupProbeTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for supply probe broken alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 46 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.46
+
+evHVACAirsysUSupProbeClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for supply probe broken alarm
+ notification"
+ ::= { evHVACAirsysUnitEntry 47 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.47
+
+evHVACAirsysUSupProbeNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ supply probe broken alarm notification"
+ ::= { evHVACAirsysUnitEntry 48 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.48
+
+evHVACAirsysUSupProbeNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for supply probe
+ broken alarm notification"
+ ::= { evHVACAirsysUnitEntry 49 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.49
+
+evHVACAirsysUSupProbeNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for supply probe broken
+ alarm notification"
+ ::= { evHVACAirsysUnitEntry 50 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.1.1.50
+
+evHVACAirsysSmokeFireEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit smoke/fire alarm enable"
+ ::= { evHVACAirsysAlarm 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.2
+
+evHVACAirsysSmokeFireActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for smoke/fire alarm
+ notification"
+ ::= { evHVACAirsysAlarm 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.3
+
+evHVACAirsysSmokeFireTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for smoke/fire alarm notification"
+ ::= { evHVACAirsysAlarm 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.4
+
+evHVACAirsysSmokeFireClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for smoke/fire alarm notification"
+ ::= { evHVACAirsysAlarm 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.5
+
+evHVACAirsysSmokeFireNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ smoke/fire alarm notification"
+ ::= { evHVACAirsysAlarm 6 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.6
+
+evHVACAirsysSmokeFireNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for smoke/fire
+ alarm notification"
+ ::= { evHVACAirsysAlarm 7 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.7
+
+evHVACAirsysSmokeFireNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for smoke/fire alarm
+ notification"
+ ::= { evHVACAirsysAlarm 8 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.8
+
+evHVACAirsysLowRoomTempEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit low room temperature alarm enable"
+ ::= { evHVACAirsysAlarm 9 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.9
+
+evHVACAirsysLowRoomTempActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for low room temperature
+ alarm notification"
+ ::= { evHVACAirsysAlarm 10 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.10
+
+evHVACAirsysLowRoomTempTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for low room temperature alarm
+ notification"
+ ::= { evHVACAirsysAlarm 11 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.11
+
+evHVACAirsysLowRoomTempClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for low room temperature alarm
+ notification"
+ ::= { evHVACAirsysAlarm 12 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.12
+
+evHVACAirsysLowRoomTempNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for low
+ room temperature alarm notification"
+ ::= { evHVACAirsysAlarm 13 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.13
+
+evHVACAirsysLowRoomTempNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for low room
+ temperature alarm notification"
+ ::= { evHVACAirsysAlarm 14 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.14
+
+evHVACAirsysLowRoomTempNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for low room temperature
+ alarm notification"
+ ::= { evHVACAirsysAlarm 15 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.15
+
+evHVACAirsysHighRoomTempEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit high room temperature alarm enable"
+ ::= { evHVACAirsysAlarm 16 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.16
+
+evHVACAirsysHighRoomTempActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for high room temperature
+ alarm notification"
+ ::= { evHVACAirsysAlarm 17 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.17
+
+evHVACAirsysHighRoomTempTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for high room temperature alarm
+ notification"
+ ::= { evHVACAirsysAlarm 18 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.18
+
+evHVACAirsysHighRoomTempClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for high room temperature alarm
+ notification"
+ ::= { evHVACAirsysAlarm 19 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.19
+
+evHVACAirsysHighRoomTempNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for high
+ room temperature alarm notification"
+ ::= { evHVACAirsysAlarm 20 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.20
+
+evHVACAirsysHighRoomTempNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for high room
+ temperature alarm notification"
+ ::= { evHVACAirsysAlarm 21 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.21
+
+evHVACAirsysHighRoomTempNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for high room
+ temperature alarm notification"
+ ::= { evHVACAirsysAlarm 22 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.22
+
+evHVACAirsysPowerEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit power failure alarm enable"
+ ::= { evHVACAirsysAlarm 23 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.23
+
+evHVACAirsysPowerActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for power failure alarm
+ notification"
+ ::= { evHVACAirsysAlarm 24 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.24
+
+evHVACAirsysPowerTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for power failure alarm
+ notification"
+ ::= { evHVACAirsysAlarm 25 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.25
+
+evHVACAirsysPowerClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for power failure alarm
+ notification"
+ ::= { evHVACAirsysAlarm 26 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.26
+
+evHVACAirsysPowerNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for power
+ failure alarm notification"
+ ::= { evHVACAirsysAlarm 27 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.27
+
+evHVACAirsysPowerNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for power failure
+ alarm notification"
+ ::= { evHVACAirsysAlarm 28 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.28
+
+evHVACAirsysPowerNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for power failure alarm
+ notification"
+ ::= { evHVACAirsysAlarm 29 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.29
+
+evHVACAirsyspLANEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit pLAN alarm enable"
+ ::= { evHVACAirsysAlarm 30 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.30
+
+evHVACAirsyspLANActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for pLAN
+ alarm notification"
+ ::= { evHVACAirsysAlarm 31 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.31
+
+evHVACAirsyspLANTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for pLAN alarm notification"
+ ::= { evHVACAirsysAlarm 32 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.32
+
+evHVACAirsyspLANClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for pLAN alarm notification"
+ ::= { evHVACAirsysAlarm 33 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.33
+
+evHVACAirsyspLANNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for pLAN
+ alarm notification"
+ ::= { evHVACAirsysAlarm 34 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.34
+
+evHVACAirsyspLANNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for pLAN alarm
+ notification"
+ ::= { evHVACAirsysAlarm 35 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.35
+
+evHVACAirsyspLANNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for pLAN alarm
+ notification"
+ ::= { evHVACAirsysAlarm 36 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.36
+
+evHVACAirsysClockEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit clock alarm enable"
+ ::= { evHVACAirsysAlarm 37 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.37
+
+evHVACAirsysClockActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for clock alarm notification"
+ ::= { evHVACAirsysAlarm 38 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.38
+
+evHVACAirsysClockTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for clock alarm notification"
+ ::= { evHVACAirsysAlarm 39 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.39
+
+evHVACAirsysClockClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for clock alarm notification"
+ ::= { evHVACAirsysAlarm 40 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.40
+
+evHVACAirsysClockNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for clock
+ alarm notification"
+ ::= { evHVACAirsysAlarm 41 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.41
+
+evHVACAirsysClockNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for clock alarm
+ notification"
+ ::= { evHVACAirsysAlarm 42 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.42
+
+evHVACAirsysClockNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for clock alarm
+ notification"
+ ::= { evHVACAirsysAlarm 43 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.43
+
+evHVACAirsysHumidProbeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit humidity probe broken alarm enable"
+ ::= { evHVACAirsysAlarm 44 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.44
+
+evHVACAirsysHumidProbeActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for humidity probe broken
+ alarm notification"
+ ::= { evHVACAirsysAlarm 45 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.45
+
+evHVACAirsysHumidProbeTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for humidity probe broken alarm
+ notification"
+ ::= { evHVACAirsysAlarm 46 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.46
+
+evHVACAirsysHumidProbeClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for humidity probe broken alarm
+ notification"
+ ::= { evHVACAirsysAlarm 47 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.47
+
+evHVACAirsysHumidProbeNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ humidity probe broken alarm notification"
+ ::= { evHVACAirsysAlarm 48 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.48
+
+evHVACAirsysHumidProbeNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for humidity probe
+ broken alarm notification"
+ ::= { evHVACAirsysAlarm 49 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.49
+
+evHVACAirsysHumidProbeNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for humidity probe broken
+ alarm notification"
+ ::= { evHVACAirsysAlarm 50 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.50
+
+evHVACAirsysOutProbeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit outdoor probe broken alarm enable"
+ ::= { evHVACAirsysAlarm 51 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.51
+
+evHVACAirsysOutProbeActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for outdoor probe broken
+ alarm notification"
+ ::= { evHVACAirsysAlarm 52 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.52
+
+evHVACAirsysOutProbeTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for outdoor probe broken alarm
+ notification"
+ ::= { evHVACAirsysAlarm 53 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.53
+
+evHVACAirsysOutProbeClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for outdoor probe broken alarm
+ notification"
+ ::= { evHVACAirsysAlarm 54 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.54
+
+evHVACAirsysOutProbeNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ outdoor probe broken alarm notification"
+ ::= { evHVACAirsysAlarm 55 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.55
+
+evHVACAirsysOutProbeNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for outdoor probe
+ broken alarm notification"
+ ::= { evHVACAirsysAlarm 56 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.56
+
+evHVACAirsysOutProbeNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for outdoor probe broken
+ alarm notification"
+ ::= { evHVACAirsysAlarm 57 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.57
+
+evHVACAirsysBothCompressEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit both compressors on alarm enable"
+ ::= { evHVACAirsysAlarm 58 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.58
+
+evHVACAirsysBothCompressActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for both compressors on
+ alarm notification"
+ ::= { evHVACAirsysAlarm 59 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.59
+
+evHVACAirsysBothCompressTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for both compressors on alarm
+ notification"
+ ::= { evHVACAirsysAlarm 60 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.60
+
+evHVACAirsysBothCompressClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for both compressors on alarm
+ notification"
+ ::= { evHVACAirsysAlarm 61 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.61
+
+evHVACAirsysBothCompressNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ both compressors on alarm notification"
+ ::= { evHVACAirsysAlarm 62 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.62
+
+evHVACAirsysBothCompressNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for both
+ compressors on alarm notification"
+ ::= { evHVACAirsysAlarm 63 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.63
+
+evHVACAirsysBothCompressNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for both compressors on
+ alarm notification"
+ ::= { evHVACAirsysAlarm 64 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.64
+
+evHVACAirsysGeneratorEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit generator running alarm enable"
+ ::= { evHVACAirsysAlarm 65 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.65
+
+evHVACAirsysGeneratorActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for generator running
+ alarm notification"
+ ::= { evHVACAirsysAlarm 66 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.66
+
+evHVACAirsysGeneratorTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for generator running alarm
+ notification"
+ ::= { evHVACAirsysAlarm 67 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.67
+
+evHVACAirsysGeneratorClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for generator running alarm
+ notification"
+ ::= { evHVACAirsysAlarm 68 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.68
+
+evHVACAirsysGeneratorNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ generator running alarm notification"
+ ::= { evHVACAirsysAlarm 69 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.69
+
+evHVACAirsysGeneratorNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for generator
+ running alarm notification"
+ ::= { evHVACAirsysAlarm 70 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.70
+
+evHVACAirsysGeneratorNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for generator running
+ alarm notification"
+ ::= { evHVACAirsysAlarm 71 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.71
+
+evHVACAirsysConnectionEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC unit lost connection alarm enable"
+ ::= { evHVACAirsysAlarm 72 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.72
+
+evHVACAirsysConnectionActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC actions to perform for lost connection
+ alarm notification"
+ ::= { evHVACAirsysAlarm 73 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.73
+
+evHVACAirsysConnectionTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC trap number for lost connection alarm
+ notification"
+ ::= { evHVACAirsysAlarm 74 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.74
+
+evHVACAirsysConnectionClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC alarm class for lost connection alarm
+ notification"
+ ::= { evHVACAirsysAlarm 75 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.75
+
+evHVACAirsysConnectionNormActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal actions to perform for
+ lost connection alarm notification"
+ ::= { evHVACAirsysAlarm 76 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.76
+
+evHVACAirsysConnectionNormTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (548..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal trap number for lost
+ connection alarm notification"
+ ::= { evHVACAirsysAlarm 77 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.77
+
+evHVACAirsysConnectionNormClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for lost connection
+ alarm notification"
+ ::= { evHVACAirsysAlarm 78 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.2.78
+
+evHVACAirsysTempBaseThresh OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC temperature base threshold"
+ ::= { evHVACAirsysTemp 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.3.1
+
+evHVACAirsysTempCoolDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC temperature cool deadband"
+ ::= { evHVACAirsysTemp 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.3.2
+
+evHVACAirsysTempHeatDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC temperature heat deadband"
+ ::= { evHVACAirsysTemp 3 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.3.3
+
+evHVACAirsysTempHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC high temperature alarm value"
+ ::= { evHVACAirsysTemp 4 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.3.4
+
+evHVACAirsysTempLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC low temperature alarm value"
+ ::= { evHVACAirsysTemp 5 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.3.5
+
+evHVACAirsysHumidMaxFree OBJECT-TYPE
+ SYNTAX Integer32 (0..99)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for lost connection
+ alarm notification"
+ ::= { evHVACAirsysHumid 1 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.4.1
+
+evHVACAirsysHumidDeadband OBJECT-TYPE
+ SYNTAX Integer32 (0..99)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Airsys HVAC return to normal class for lost connection
+ alarm notification"
+ ::= { evHVACAirsysHumid 2 }
+ --1.3.6.1.4.1.3052.10.2.12.19.4.4.2
+
+
+--***************************************************************************************
+--EVPS Section 2.12.20
+--***************************************************************************************
+
+evpsEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EVPS (Emerson Vortex Power System) enable."
+ ::= { evEvps 1 }
+ --1.3.6.1.4.1.3052.10.2.12.20.1
+
+evpsIPAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EVPS IP address."
+ ::= { evEvps 2 }
+ --1.3.6.1.4.1.3052.10.2.12.20.2
+
+evpsPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EVPS IP web port."
+ ::= { evEvps 3 }
+ --1.3.6.1.4.1.3052.10.2.12.20.3
+
+evpsTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EVPS IP timeout."
+ ::= { evEvps 4 }
+ --1.3.6.1.4.1.3052.10.2.12.20.4
+
+
+--***************************************************************************************
+--Access Control Device Management Section 2.12.21
+--***************************************************************************************
+
+acActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the access control event."
+ ::= { accessControl 2 }
+ --1.3.6.1.4.1.3052.10.2.12.21.2
+
+acTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the access control event."
+ ::= { accessControl 3 }
+ --1.3.6.1.4.1.3052.10.2.12.21.3
+
+acClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the access control event."
+ ::= { accessControl 4 }
+ --1.3.6.1.4.1.3052.10.2.12.21.4
+
+accessControlDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AccessControlDevice
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of access control devices for Access Control Device Management."
+ ::= { accessControl 10 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10
+
+accessControlDeviceEntry OBJECT-TYPE
+ SYNTAX AccessControlDevice
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of access control devices for Access Control Device Management."
+ INDEX { acdIndex }
+ ::= { accessControlDeviceTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1
+
+acdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of access control devices for Access Control Device Management."
+ ::= { accessControlDeviceEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.1
+
+acdEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable management for this access control device."
+ ::= { accessControlDeviceEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.2
+
+acdName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the access control device for informational purpose only."
+ ::= { accessControlDeviceEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.3
+
+acdReader OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The kind of access control device."
+ ::= { accessControlDeviceEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.4
+
+acdWiegandES OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Index of the Wiegand interface hardware instance allocated as the access control device."
+ ::= { accessControlDeviceEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.5
+
+acdWiegandPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which wiegand on the wiegand EventSensor to use for as the access control device."
+ ::= { accessControlDeviceEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.6
+
+acdRelayType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of relay which activates the door strike."
+ ::= { accessControlDeviceEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.7
+
+acdRelayES OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which relay EventSensor is connected to the door strike."
+ ::= { accessControlDeviceEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.8
+
+acdRelayPoint OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which relay on the relay EventSensor is connected to the door strike."
+ ::= { accessControlDeviceEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.9
+
+acdOpenTime OBJECT-TYPE
+ SYNTAX Integer32 (1..25)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { accessControlDeviceEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.10
+
+acdUserGroup OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User group to which this access control device applies."
+ ::= { accessControlDeviceEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.11
+
+accessControlUserTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AccessControlUser
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of access control users for Access Control Device Management."
+ ::= { accessControl 11 }
+ --1.3.6.1.4.1.3052.10.2.12.21.11
+
+accessControlUserEntry OBJECT-TYPE
+ SYNTAX AccessControlUser
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of access control users for Access Control Device Management."
+ INDEX { acuIndexUserGroup, acuIndexUser }
+ ::= { accessControlUserTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.21.11.1
+
+acuIndexUserGroup OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of access control devices for Access Control Device Management
+ which corresponds to the user group containing the user."
+ ::= { accessControlUserEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.1
+
+acuIndexUser OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of access control devices for Access Control Device Management
+ which corresponds to the user within the user group."
+ ::= { accessControlUserEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.2
+
+acuEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable this access control user."
+ ::= { accessControlUserEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.3
+
+acuName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this access control user."
+ ::= { accessControlUserEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.4
+
+acuSn OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Serial number of the card associated with the user."
+ ::= { accessControlUserEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.5
+
+acuSunBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Sundays when this user should be granted access."
+ ::= { accessControlUserEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.6
+
+acuSunEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Sundays when this user should be forbidden access."
+ ::= { accessControlUserEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.7
+
+acuMonBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Mondays when this user should be granted access."
+ ::= { accessControlUserEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.8
+
+acuMonEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Mondays when this user should be forbidden access."
+ ::= { accessControlUserEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.9
+
+acuTueBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Tuesdays when this user should be granted access."
+ ::= { accessControlUserEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.10
+
+acuTueEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Tuesdays when this user should be forbidden access."
+ ::= { accessControlUserEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.11
+
+acuWedBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Wednesdays when this user should be granted access."
+ ::= { accessControlUserEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.12
+
+acuWedEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Wednesdays when this user should be forbidden access."
+ ::= { accessControlUserEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.13
+
+acuThuBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Thursdays when this user should be granted access."
+ ::= { accessControlUserEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.14
+
+acuThuEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Thursdays when this user should be forbidden access."
+ ::= { accessControlUserEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.15
+
+acuFriBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Fridays when this user should be granted access."
+ ::= { accessControlUserEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.16
+
+acuFriEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Fridays when this user should be forbidden access."
+ ::= { accessControlUserEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.17
+
+acuSatBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Saturdays when this user should be granted access."
+ ::= { accessControlUserEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.18
+
+acuSatEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) on Saturdays when this user should be forbidden access."
+ ::= { accessControlUserEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.12.21.10.1.19
+
+
+
+--***************************************************************************************
+--Telemetry Section 2.12.22
+--***************************************************************************************
+
+telemetryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TelemetryPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { telemetry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1
+
+telemetryEntry OBJECT-TYPE
+ SYNTAX TelemetryPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of telemetry points"
+ INDEX { telemetryPointIndex }
+ ::= { telemetryTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1.1
+
+telemetryPointIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of telemetry points."
+ ::= { telemetryEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1.1.1
+
+telemetryPointName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of telemetry point for information purpose only."
+ ::= { telemetryEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1.1.2
+
+telemetryPointKey OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key for telemetry point that specifies the telemetry data source."
+ ::= { telemetryEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1.1.3
+
+telemetryPointType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNP3 type for telemetry point"
+ ::= { telemetryEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1.1.4
+
+telemetryPointClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNP3 class for telemetry point"
+ ::= { telemetryEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1.1.5
+
+telemetryPointDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for telemetry point"
+ ::= { telemetryEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1.1.6
+
+telemetryPointShortcode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Shortcode for telemetry point"
+ ::= { telemetryEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.12.22.1.1.7
+
+--***************************************************************************************
+--Site Security Section 2.12.23
+--***************************************************************************************
+
+siteSecIntrusionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SiteSecIntrusion
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of for Site Security"
+ ::= { siteSecurity 1 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1
+
+siteSecEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Security zone 1 to 10 is ON or OFF stating that a zone is configured properly"
+ ::= { siteSecIntrusionTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.1
+
+siteSecDisarmed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON or OFF if ON the zone will not detect intrusion because it is disarmed, OFF arms the zone to detect intrusion"
+ ::= { siteSecIntrusionTable 2 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.2
+
+
+siteSecName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name given to the zone"
+ ::= { siteSecIntrusionTable 3 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.3
+
+
+siteSecState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ALARM/DISARMED/DISABLED/INTRUDER/REARMING one of five states the zone is in"
+ ::= { siteSecIntrusionTable 4 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.4
+
+
+siteSecSensorES OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Event Sensors related to a particular zone"
+ ::= { siteSecIntrusionTable 5 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.5
+
+
+siteSecSensorPoint OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The point in conjunction with event-sensor and zone"
+ ::= { siteSecIntrusionTable 6 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.6
+
+
+siteSecIntrusionThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait for a disarm event"
+ ::= { siteSecIntrusionTable 7 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.7
+
+
+siteSecReader OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Comma separated string of readers that disarms a zone"
+ ::= { siteSecIntrusionTable 8 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.8
+
+
+siteSecReaderThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of seconds a user has to disable a detected intrusion via the reader configured for the zone"
+ ::= { siteSecIntrusionTable 9 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.9
+
+
+siteSecButtonEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Button to disable an alarm is PRESENT/NOT PRESENT"
+ ::= { siteSecIntrusionTable 10 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.10
+
+
+siteSecButtonES OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Configured event-sensor for the Site-Security button"
+ ::= { siteSecIntrusionTable 11 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.11
+
+
+siteSecButtonPoint OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Configured pont for the Site-Security button"
+ ::= { siteSecIntrusionTable 12 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.12
+
+
+siteSecButtonType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Button type configured : MOMENTARY/TOGGLE"
+ ::= { siteSecIntrusionTable 13 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.13
+
+
+siteSecButtonThresholdArm OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to hold button to arm a zone"
+ ::= { siteSecIntrusionTable 14 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.14
+
+
+siteSecButtonThresholdDisarm OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to hold button to disarm a zone"
+ ::= { siteSecIntrusionTable 15 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.15
+
+
+siteSecSirenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable realy output for siren"
+ ::= { siteSecIntrusionTable 16 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.16
+
+
+siteSecSirenES OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event-sensor relay location of siren for the zone"
+ ::= { siteSecIntrusionTable 17 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.17
+
+
+siteSecSirenPoint OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event-sensor point location of siren for the zone"
+ ::= { siteSecIntrusionTable 18 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.18
+
+
+siteSecRearmDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A delay in seconds after a rearm event before the site is actually rearmed"
+ ::= { siteSecIntrusionTable 19 }
+ --1.3.6.1.4.1.3052.10.2.12.23.1.19
+
+siteSecMotionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SiteSecMotion
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of for Site Security motion sensors"
+ ::= { siteSecurity 2 }
+ --1.3.6.1.4.1.3052.10.2.12.23.2
+
+siteSecMotionES OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event-sensor for motion detection device"
+ ::= { siteSecMotionTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.23.2.1
+
+ siteSecMotionPoint OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Point for event-sensor motion detection device"
+ ::= { siteSecMotionTable 2 }
+ --1.3.6.1.4.1.3052.10.2.12.23.2.2
+
+siteSecMotionEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable or disable motion alarm"
+ ::= { siteSecMotionTable 3 }
+ --1.3.6.1.4.1.3052.10.2.12.23.2.3
+
+siteSecMotionName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of the motion sensor"
+ ::= { siteSecMotionTable 4 }
+ --1.3.6.1.4.1.3052.10.2.12.23.2.4
+
+siteSecMotionThresholdRearm OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A threshold to wait for no motion before rearming"
+ ::= { siteSecMotionTable 5 }
+ --1.3.6.1.4.1.3052.10.2.12.23.2.5
+
+siteSecDoorAjarTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SiteSecDoorAjar
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of for Site Security Door Ajar sensors"
+ ::= { siteSecurity 3 }
+ --1.3.6.1.4.1.3052.10.2.12.23.3
+
+siteSecDoorAjarEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable or disable door ajar sensor"
+ ::= { siteSecDoorAjarTable 1 }
+ --1.3.6.1.4.1.3052.10.2.12.23.3.1
+
+siteSecDoorAjarName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for the door ajar sensor"
+ ::= { siteSecDoorAjarTable 2 }
+ --1.3.6.1.4.1.3052.10.2.12.23.3.2
+
+siteSecDoorAjarES OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event-sensor for door ajar detection device"
+
+ ::= { siteSecDoorAjarTable 3 }
+ --1.3.6.1.4.1.3052.10.2.12.23.3.3
+
+siteSecDoorAjarPoint OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Point for event-sensor door ajar detection device"
+
+ ::= { siteSecDoorAjarTable 4 }
+ --1.3.6.1.4.1.3052.10.2.12.23.3.4
+
+siteSecDoorAjarThresholdNormal OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Threshold to wait in seconds before tripping the door ajar alarm "
+ ::= { siteSecDoorAjarTable 5 }
+ --1.3.6.1.4.1.3052.10.2.12.23.3.5
+
+siteSecDoorAjarThresholdExtraTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Extra seconds added to the door ajar threshold for disabled person before door ajar alarm is set"
+ ::= { siteSecDoorAjarTable 6 }
+ --1.3.6.1.4.1.3052.10.2.12.23.3.6
+
+
+
+--***************************************************************************************
+--Action Section 2.14
+--***************************************************************************************
+
+
+
+actionCallNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionCallNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of phone numbers to dial for modem actions"
+ ::= { action 1 }
+ --1.3.6.1.4.1.3052.10.2.14.1
+
+actionCallNumberEntry OBJECT-TYPE
+ SYNTAX ActionCallNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of phone numbers to dial for modem actions"
+ INDEX { actionCallNumberIndex }
+ ::= { actionCallNumberTable 1 }
+ --1.3.6.1.4.1.3052.10.2.14.1.1
+
+actionCallNumberIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of phone numbers to dial for modem actions"
+ ::= { actionCallNumberEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.14.1.1.1
+
+actionCallNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number to dial for this action slot"
+ ::= { actionCallNumberEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.14.1.1.2
+
+actionPagerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionPagerConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of pager configurations"
+ ::= { action 2 }
+ --1.3.6.1.4.1.3052.10.2.14.2
+
+actionPagerEntry OBJECT-TYPE
+ SYNTAX ActionPagerConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of pager configurations"
+ INDEX { actionPagerIndex }
+ ::= { actionPagerTable 1 }
+ --1.3.6.1.4.1.3052.10.2.14.2.1
+
+actionPagerIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "index for table of pager configurations"
+ ::= { actionPagerEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.14.2.1.1
+
+actionPagerType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "type of this pager configuration"
+ ::= { actionPagerEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.14.2.1.2
+
+actionPagerNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "phone number to dial for this pager configuration"
+ ::= { actionPagerEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.14.2.1.3
+
+actionPagerID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID to use for this pager configuration"
+ ::= { actionPagerEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.14.2.1.4
+
+actionPagerMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "message to use for this pager configuration"
+ ::= { actionPagerEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.14.2.1.5
+
+actionPagerPostCalloutDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait after dialing before sending ID"
+ ::= { actionPagerEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.14.2.1.6
+
+actionPagerPostIDDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait after sending ID to send message"
+ ::= { actionPagerEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.14.2.1.7
+
+actionSchedEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable action schedule"
+ ::= { actionSched 1 }
+ --1.3.6.1.4.1.3052.10.2.14.3.1
+
+actionSchedBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "action schedule begin time (HH:MM)"
+ ::= { actionSched 2 }
+ --1.3.6.1.4.1.3052.10.2.14.3.2
+
+actionSchedEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "action schedule end time (HH:MM)"
+ ::= { actionSched 3 }
+ --1.3.6.1.4.1.3052.10.2.14.3.3
+
+actionSchedWeekdaysOnly OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF whether the action schedule applies to weekdays only
+ (ON) or all days (OFF)"
+ ::= { actionSched 4 }
+ --1.3.6.1.4.1.3052.10.2.14.3.4
+
+actionAsentriaRequireAck OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Asentria action requires an ack from the receiver"
+ ::= { actionAsentria 1 }
+ --1.3.6.1.4.1.3052.10.2.14.4.1
+
+actionAsentriaVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "version 1.0 or 1.1"
+ ::= { actionAsentria 2 }
+ --1.3.6.1.4.1.3052.10.2.14.4.2
+
+actionAsentriaTCPPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port used for TCP-based Asentria alarms"
+ ::= { actionAsentria 3 }
+ --1.3.6.1.4.1.3052.10.2.14.4.3
+
+actionHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of network hosts to use for network-based actions"
+ ::= { action 6 }
+ --1.3.6.1.4.1.3052.10.2.14.6
+
+actionHostEntry OBJECT-TYPE
+ SYNTAX ActionHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of network hosts to use for network-based
+ actions"
+ INDEX { actionHostIndex }
+ ::= { actionHostTable 1 }
+ --1.3.6.1.4.1.3052.10.2.14.6.1
+
+actionHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of network hosts to use for network-based
+ actions"
+ ::= { actionHostEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.14.6.1.1
+
+actionHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Hostname/IP address used as destination for network-based
+ action (e.g., trap)"
+ ::= { actionHostEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.14.6.1.2
+
+actionEmailTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionEmailConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of email addresses to use for email actions"
+ ::= { action 7 }
+ --1.3.6.1.4.1.3052.10.2.14.7
+
+actionEmailEntry OBJECT-TYPE
+ SYNTAX ActionEmailConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of email addresses to use for email actions"
+ INDEX { actionEmailIndex }
+ ::= { actionEmailTable 1 }
+ --1.3.6.1.4.1.3052.10.2.14.7.1
+
+actionEmailIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of email addresses to use for email actions"
+ ::= { actionEmailEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.14.7.1.1
+
+actionEmail OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "email address"
+ ::= { actionEmailEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.14.7.1.2
+
+actionParseError OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When a user attempts to configure an invalid action setting/
+ object, this object says why it was invalid."
+ ::= { action 8 }
+ --1.3.6.1.4.1.3052.10.2.14.8
+
+--***************************************************************************************
+--System Section 2.16
+--***************************************************************************************
+
+
+sysTimeAutoDST OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF automatically adjust for Daylight Savings Time"
+ ::= { sysTime 1 }
+ --1.3.6.1.4.1.3052.10.2.16.1.1
+
+sysTimeGMTOffset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Absolute value of offset (hours) from GMT of the timezone"
+ ::= { sysTime 2 }
+ --1.3.6.1.4.1.3052.10.2.16.1.2
+
+sysTimeGMTDirection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Direction (AHEAD/BEHIND) of timezone relative to GMT"
+ ::= { sysTime 3 }
+ --1.3.6.1.4.1.3052.10.2.16.1.3
+
+
+sysTimeNetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Network time mode"
+ ::= { sysTimeNet 1 }
+ --1.3.6.1.4.1.3052.10.2.16.1.4.1
+
+sysTimeNetHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NetworkTimeHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of hosts to use for network time services"
+ ::= { sysTimeNet 2 }
+ --1.3.6.1.4.1.3052.10.2.16.1.4.2
+
+sysTimeNetHostEntry OBJECT-TYPE
+ SYNTAX NetworkTimeHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of hosts to use for network time services"
+ INDEX { sysTimeNetHostIndex }
+ ::= { sysTimeNetHostTable 1 }
+ --1.3.6.1.4.1.3052.10.2.16.1.4.2.1
+
+sysTimeNetHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of hosts to use for network time services"
+ ::= { sysTimeNetHostEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.16.1.4.2.1.1
+
+sysTimeNetHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "host to use for network time services"
+ ::= { sysTimeNetHostEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.16.1.4.2.1.2
+
+sysPTTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout (minutes) of inactivity after which a pass-through
+ session is terminated (0 means it never terminates)"
+ ::= { sysPT 1 }
+ --1.3.6.1.4.1.3052.10.2.16.2.1
+
+sysPTEndPause OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "number of 16ths of a second between escape characters
+ received on pass-through origin IO handle that are reuired
+ for the escape characters to register as pass-through escape
+ characters in the pass-through escape sequence. Set to 0 to
+ make the escape character register as part of the pass-
+ through escape sequence without requiring a pause."
+ ::= { sysPT 2 }
+ --1.3.6.1.4.1.3052.10.2.16.2.2
+
+sysPTJoinable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable joinable pass-through sessions."
+ ::= { sysPT 3 }
+ --1.3.6.1.4.1.3052.10.2.16.2.3
+
+sysMTU OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum transfer unit for ethernet interfaces"
+ ::= { sys 3 }
+ --1.3.6.1.4.1.3052.10.2.16.3
+
+sysAnswerString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String displayed upon login"
+ ::= { sys 4 }
+ --1.3.6.1.4.1.3052.10.2.16.4
+
+sysEventFileID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID string for events file"
+ ::= { sys 6 }
+ --1.3.6.1.4.1.3052.10.2.16.6
+
+sysEscapeCharacter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Decimal ASCII code of the system escape character"
+ ::= { sys 7 }
+ --1.3.6.1.4.1.3052.10.2.16.7
+
+sysTimeStampTimeFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Format of time stamp: HH:MM,HH:MM:SS,BLANK"
+ ::= { sysTimeStamp 1 }
+ --1.3.6.1.4.1.3052.10.2.16.8.1
+
+sysTimeStampDateFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Format of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK"
+ ::= { sysTimeStamp 2 }
+ --1.3.6.1.4.1.3052.10.2.16.8.2
+
+sysTimeStampSpaceAfter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Inlude a space after timestamp"
+ ::= { sysTimeStamp 3 }
+ --1.3.6.1.4.1.3052.10.2.16.8.3
+
+sysLogMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Syslog mode: disabled, emit UDP (REMOTE), save in a
+ rotating file set (FILE), or emit on a listening socket
+ (SERVER)"
+ ::= { sysLog 1 }
+ --1.3.6.1.4.1.3052.10.2.16.9.1
+
+sysLoghost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Syslog host: destination machine when syslog mode is REMOTE"
+ ::= { sysLog 2 }
+ --1.3.6.1.4.1.3052.10.2.16.9.2
+
+sysLogFilter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String describing what functions place data in the syslog"
+ ::= { sysLog 3 }
+ --1.3.6.1.4.1.3052.10.2.16.9.3
+
+sysLogFileSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Size (in KB) of syslog files (when syslog mode is SERVER or
+ FILE)"
+ ::= { sysLog 4 }
+ --1.3.6.1.4.1.3052.10.2.16.9.4
+
+sysLogFileCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of files in syslog file set (when syslog mode is
+ SERVER or FILE)"
+ ::= { sysLog 5 }
+ --1.3.6.1.4.1.3052.10.2.16.9.5
+
+sysLogListenPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which the unit listens for a connection on
+ which syslog data is dumped (when syslog mode is SERVER)"
+ ::= { sysLog 6 }
+ --1.3.6.1.4.1.3052.10.2.16.9.6
+
+sysCRDBCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacity of Call Record Database (in KB)"
+ ::= { sysCRDB 1 }
+ --1.3.6.1.4.1.3052.10.2.16.10.1
+
+sysCRDBPercentFull OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of the CRDB used"
+ ::= { sysCRDB 2 }
+ --1.3.6.1.4.1.3052.10.2.16.10.2
+
+
+sysCRDBFileIDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CRDBFileIDConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CRDB file IDs"
+ ::= { sysCRDB 3 }
+ --1.3.6.1.4.1.3052.10.2.16.10.3
+
+sysCRDBFileIDEntry OBJECT-TYPE
+ SYNTAX CRDBFileIDConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CRDB file IDs"
+ INDEX { sysCRDBFileIDIndex }
+ ::= { sysCRDBFileIDTable 1 }
+ --1.3.6.1.4.1.3052.10.2.16.10.3.1
+
+sysCRDBFileIDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CRDB file IDs"
+ ::= { sysCRDBFileIDEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.16.10.3.1.1
+
+sysCRDBFileID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID of CRDB file for this port-associated file x"
+ ::= { sysCRDBFileIDEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.16.10.3.1.2
+
+sysCRDBFileEnforceMinTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CRDBFileEnforceMinConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CRDB file minimum size enforcement settings"
+ ::= { sysCRDB 4 }
+ --1.3.6.1.4.1.3052.10.2.16.10.4
+
+sysCRDBFileEnforceMinEntry OBJECT-TYPE
+ SYNTAX CRDBFileEnforceMinConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CRDB file minimum size enforcement
+ settings"
+ INDEX { sysCRDBFileEnforceMinIndex }
+ ::= { sysCRDBFileEnforceMinTable 1 }
+ --1.3.6.1.4.1.3052.10.2.16.10.4.1
+
+sysCRDBFileEnforceMinIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..24)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CRDB file minimum size enforcement
+ settings"
+ ::= { sysCRDBFileEnforceMinEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.16.10.4.1.1
+
+sysCRDBFileEnforceMin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enforce minimum size for this CRDB file x"
+ ::= { sysCRDBFileEnforceMinEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.16.10.4.1.2
+
+sysCharMask OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Character mask used for ignoring certain characters on
+ serial ports when assembling data records (when port mode is
+ ASCII)"
+ ::= { sys 11 }
+ --1.3.6.1.4.1.3052.10.2.16.11
+
+sysPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Prompt to use in a commnand session"
+ ::= { sys 12 }
+ --1.3.6.1.4.1.3052.10.2.16.12
+
+sysBootStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "String describing the boot status of the unit (Booted OK/
+ still booting"
+ ::= { sys 13 }
+ --1.3.6.1.4.1.3052.10.2.16.13
+
+--***************************************************************************************
+--Sys Location Section 2.16.14
+--***************************************************************************************
+
+sysLocLatitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Latitude portion of geographic coordinates as string"
+ ::= { sysLoc 1 }
+ --1.3.6.1.4.1.3052.10.2.16.14.1
+
+sysLocLongitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Longitude portion of geographic coordinates as string"
+ ::= { sysLoc 2 }
+ --1.3.6.1.4.1.3052.10.2.16.14.2
+
+sysLocXOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "X-offset portion of geographic coordinates as string"
+ ::= { sysLoc 3 }
+ --1.3.6.1.4.1.3052.10.2.16.14.3
+
+sysLocYOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Y offset portion of geographic coordinates as string"
+ ::= { sysLoc 4 }
+ --1.3.6.1.4.1.3052.10.2.16.14.4
+
+sysLocAngle OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Angle portion of geographic coordinates as string"
+ ::= { sysLoc 5 }
+ --1.3.6.1.4.1.3052.10.2.16.14.5
+
+sysLocAltitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Altitude as string"
+ ::= { sysLoc 6 }
+ --1.3.6.1.4.1.3052.10.2.16.14.6
+
+--***************************************************************************************
+--Sys Asset Managment 2.16.15
+--***************************************************************************************
+sysAMManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device manufacturer"
+ ::= { sysAssetMgmt 1 }
+ --1.3.6.1.4.1.3052.10.2.16.15.1
+
+sysAMProduct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device product description (i.e., model or model number)"
+ ::= { sysAssetMgmt 2 }
+ --1.3.6.1.4.1.3052.10.2.16.15.2
+
+sysAMSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manufacturer serial number for device"
+ ::= { sysAssetMgmt 3 }
+ --1.3.6.1.4.1.3052.10.2.16.15.3
+
+sysAMHardwareOptions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hardware options currently installed on device"
+ ::= { sysAssetMgmt 4 }
+ --1.3.6.1.4.1.3052.10.2.16.15.4
+
+sysAMSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently-running software version on device"
+ ::= { sysAssetMgmt 5 }
+ --1.3.6.1.4.1.3052.10.2.16.15.5
+
+sysAMSiteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Site Name of device (user definable, also known as the
+ siteName object under the productIds branch."
+ ::= { sysAssetMgmt 6 }
+ --1.3.6.1.4.1.3052.10.2.16.15.6
+
+
+--***************************************************************************************
+--Sys File Transfer Section 2.16.17
+--***************************************************************************************
+
+sysFileTransferStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start/cancel file transfer, or check transfer status. To start, set this object
+ to 'start'. To cancel, set this object to 'cancel'. To check status, get the
+ object"
+ ::= { sysFileTransfer 1 }
+ --1.3.6.1.4.1.3052.10.2.16.17.1
+
+sysFileTransferURL OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "URL (describing protocol, host, directory, and file) on which file transfer
+ function operates."
+ ::= { sysFileTransfer 2 }
+ --1.3.6.1.4.1.3052.10.2.16.17.2
+
+sysFileTransferUsername OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Username for user account at the resource specified by sysFileTransferURL."
+ ::= { sysFileTransfer 3 }
+ --1.3.6.1.4.1.3052.10.2.16.17.3
+
+sysFileTransferPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Password for user account at the resource specified by sysFileTransferURL."
+ ::= { sysFileTransfer 4 }
+ --1.3.6.1.4.1.3052.10.2.16.17.4
+
+--***************************************************************************************
+--Sys Update Section 2.16.18
+--***************************************************************************************
+
+sysUpdateStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Check time/result of last update attempt."
+ ::= { sysUpdate 1 }
+ --1.3.6.1.4.1.3052.10.2.16.18.1
+
+
+--***************************************************************************************
+--Audit Log Section 2.17
+--***************************************************************************************
+
+auditLogEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable audit log"
+ ::= { auditLog 1 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStoreResets OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when the unit resets"
+ ::= { auditLog 2 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStoreCommands OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores commands entered in a command
+ session"
+ ::= { auditLog 3 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStoreOutputs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores output (relay output and power output)
+ activity"
+ ::= { auditLog 4 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStoreAlarmActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores action delivery activity"
+ ::= { auditLog 5 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStorePwdFailures OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when user was denied login"
+ ::= { auditLog 6 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStoreLogins OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when a user was allowed login"
+ ::= { auditLog 7 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStoreSHSK OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores serial handshaking status
+ (regardless of serial handshaking event)"
+ ::= { auditLog 8 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStorePassthrough OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores pass-through activity"
+ ::= { auditLog 9 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStoreInactivity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when sessions expire due to
+ inactivity"
+ ::= { auditLog 10 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogStorePolling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores CRDB polling activity"
+ ::= { auditLog 11 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+auditLogMaxSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum size (in KB) of audit log"
+ ::= { auditLog 12 }
+ --1.3.6.1.4.1.3052.10.2.17.1
+
+--***************************************************************************************
+--Scripting Section 2.17
+--***************************************************************************************
+
+scrGlobalEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable scripting"
+ ::= { scripting 1 }
+ --1.3.6.1.4.1.3052.10.2.18.1
+
+scrDTRCtrlPortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingDTRCtrlPortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of DTR control port enables"
+ ::= { scripting 2 }
+ --1.3.6.1.4.1.3052.10.2.18.2
+
+scrDTRCtrlPortEnableEntry OBJECT-TYPE
+ SYNTAX ScriptingDTRCtrlPortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of DTR control port enables"
+ INDEX { scrDTRCtrlPortEnableIndex }
+ ::= { scrDTRCtrlPortEnableTable 1 }
+ --1.3.6.1.4.1.3052.10.2.18.2.1
+
+scrDTRCtrlPortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of DTR control port enables"
+ ::= { scrDTRCtrlPortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.18.2.1.1
+
+scrDTRCtrlPortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable DTR control of scripting for this port"
+ ::= { scrDTRCtrlPortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.18.2.1.2
+
+
+scrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of scripts"
+ ::= { scripting 3 }
+ --1.3.6.1.4.1.3052.10.2.18.3
+
+scrEntry OBJECT-TYPE
+ SYNTAX ScriptingConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of scripts"
+ INDEX { scrIndex }
+ ::= { scrTable 1 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1
+
+scrIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of scripts"
+ ::= { scrEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.1
+
+scrEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this script"
+ ::= { scrEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.2
+
+scrName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of this script"
+ ::= { scrEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.3
+
+scrFilename OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filename for this script"
+ ::= { scrEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.4
+
+scrRunAlways OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script always runs"
+ ::= { scrEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.5
+
+scrRunAtStartup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script runs at startup"
+ ::= { scrEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.6
+
+scrRunScheduled OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script runs at a certain time of day"
+ ::= { scrEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.7
+
+scrScheduleTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) this script is scheduled to run"
+ ::= { scrEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.8
+
+scrArguments OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Arguments for this script"
+ ::= { scrEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.9
+
+scrRepeatInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How often this script runs (minutes)"
+ ::= { scrEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.18.3.1.10
+
+scrVolatileStringTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of volatile string settings for use in
+ scripts."
+ ::= { scripting 4 }
+ --1.3.6.1.4.1.3052.10.2.18.4
+
+scrVolatileStringEntry OBJECT-TYPE
+ SYNTAX ScriptingVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of volatile script string
+ settings"
+ INDEX { scrVolatileStringIndex }
+ ::= { scrVolatileStringTable 1 }
+ --1.3.6.1.4.1.3052.10.2.18.4.1
+
+scrVolatileStringIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of volatile script string
+ settings"
+ ::= { scrVolatileStringEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.18.4.1.1
+
+scrVolatileString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volatile string for use in scripts. Use this
+ object to cache frequently-changing string values
+ or string values that do not need to persist
+ through reset. This object corresponds to the
+ scripting.vstring[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object."
+ ::= { scrVolatileStringEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.18.4.1.2
+
+scrVolatileIntTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of volatile integer settings for use in
+ scripts."
+ ::= { scripting 5 }
+ --1.3.6.1.4.1.3052.10.2.18.5
+
+scrVolatileIntEntry OBJECT-TYPE
+ SYNTAX ScriptingVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of volatile script integer
+ settings"
+ INDEX { scrVolatileIntIndex }
+ ::= { scrVolatileIntTable 1 }
+ --1.3.6.1.4.1.3052.10.2.18.5.1
+
+scrVolatileIntIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of volatile script integer
+ settings"
+ ::= { scrVolatileIntEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.18.5.1.1
+
+scrVolatileInt OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volatile integer for use in scripts. Use this
+ object to cache frequently-changing integer values
+ or integer values that do not need to persist
+ through reset. This object corresponds to the
+ scripting.vint[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object."
+ ::= { scrVolatileIntEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.18.5.1.2
+
+scrNonVolatileStringTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingNonVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of non-volatile string settings for use in
+ scripts."
+ ::= { scripting 6 }
+ --1.3.6.1.4.1.3052.10.2.18.6
+
+scrNonVolatileStringEntry OBJECT-TYPE
+ SYNTAX ScriptingNonVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of non-volatile script string
+ settings"
+ INDEX { scrNonVolatileStringIndex }
+ ::= { scrNonVolatileStringTable 1 }
+ --1.3.6.1.4.1.3052.10.2.18.6.1
+
+scrNonVolatileStringIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of non-volatile script string
+ settings"
+ ::= { scrNonVolatileStringEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.18.6.1.1
+
+scrNonVolatileString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Non-volatile string for use in scripts. Use this
+ object to store values that need to persist
+ through reset. This object corresponds to the
+ scripting.nvstring[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object. Note: to store frequently-
+ changing integers, use the scrVolatileString object,
+ otherwise your scripts may cause unnecessary wear of
+ the non-volatile storage medium on the unit."
+ ::= { scrNonVolatileStringEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.18.6.1.2
+
+scrNonVolatileIntTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingNonVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of non-volatile integer settings for use in
+ scripts."
+ ::= { scripting 7 }
+ --1.3.6.1.4.1.3052.10.2.18.7
+
+scrNonVolatileIntEntry OBJECT-TYPE
+ SYNTAX ScriptingNonVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of non-volatile script integer
+ settings"
+ INDEX { scrNonVolatileIntIndex }
+ ::= { scrNonVolatileIntTable 1 }
+ --1.3.6.1.4.1.3052.10.2.18.7.1
+
+scrNonVolatileIntIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of non-volatile script integer
+ settings"
+ ::= { scrNonVolatileIntEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.18.7.1.1
+
+scrNonVolatileInt OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Non-volatile integer for use in scripts. Use this
+ object to store integer values that need to persist
+ through reset. This object corresponds to the
+ scripting.nvint[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object. Note: to store frequently-
+ changing integers, use the scrVolatileInt object,
+ otherwise your scripts may cause unnecessary wear of
+ the non-volatile storage medium on the unit."
+ ::= { scrNonVolatileIntEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.18.7.1.2
+
+
+--***************************************************************************************
+--Generator Section 2.19
+--***************************************************************************************
+
+genSetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable genset functionality; that is, a generator is in use."
+ ::= { genSet 1 }
+ --1.3.6.1.4.1.3052.10.2.19.1.1
+
+genSetRelayEs OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which EventSensor has the relay which starts the generator,
+ for genset relay configuration 1 only. This object maps to the
+ same setting as genSetRelayTableEs.1."
+ ::= { genSetRelay 1 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.1
+
+genSetRelayPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..13)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which relay starts the generator, for genset relay configuration
+ 1 only. This object maps to the same setting as genSetRelayTablePoint.1."
+ ::= { genSetRelay 2 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.2
+
+genSetRelayRunningstate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which relay state corresponds with the generator starting/running.
+ This object maps to the same setting as genSetRelayTableRunningstate.1."
+ ::= { genSetRelay 3 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.3
+
+genSetRelayTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF GenSetRelaySequence
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of relays for genset ignition."
+ ::= { genSetRelay 5 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.5
+
+genSetRelayTableEntry OBJECT-TYPE
+ SYNTAX GenSetRelaySequence
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of relays for genset ignition."
+ INDEX { genSetRelayTableIndex }
+ ::= { genSetRelayTable 1 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.5.1
+
+genSetRelayTableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of relays for genset ignition."
+ ::= { genSetRelayTableEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.1
+
+genSetRelayTableEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable this relay for starting the generator."
+ ::= { genSetRelayTableEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.2
+
+genSetRelayTableEs OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which EventSensor has the relay which starts the generator, for this
+ genset relay configuration specified by the table index."
+ ::= { genSetRelayTableEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.3
+
+genSetRelayTablePoint OBJECT-TYPE
+ SYNTAX Integer32 (1..13)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which relay point on the EventSensor used for starting the generator,
+ for this genset relay configuration specified by the table index."
+ ::= { genSetRelayTableEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.4
+
+genSetRelayTableRunningstate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which relay state corresponds with the generator starting/running,
+ for this genset relay configuration specified by the table index."
+ ::= { genSetRelayTableEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.19.1.2.5.1.5
+
+genSetCCEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable generator running detection functionality; that is, the
+ associated CC is valid for determining if generator is running."
+ ::= { genSetCC 1 }
+ --1.3.6.1.4.1.3052.10.2.19.1.3.1
+
+genSetCCEs OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which CC EventSensor has the CC which is connected to the genertor
+ running detection monitor."
+ ::= { genSetCC 2 }
+ --1.3.6.1.4.1.3052.10.2.19.1.3.2
+
+genSetCCPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which CC is connected to the genertor running detection monitor."
+ ::= { genSetCC 3 }
+ --1.3.6.1.4.1.3052.10.2.19.1.3.3
+
+genSetCCRunningState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which CC physical state corresponds with the generator running."
+ ::= { genSetCC 4 }
+ --1.3.6.1.4.1.3052.10.2.19.1.3.4
+
+genSetCCDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How long (in seconds) to wait for the generator to indicate
+ itself as running after engaging the generator-starting mechanism."
+ ::= { genSetCC 5 }
+ --1.3.6.1.4.1.3052.10.2.19.1.3.5
+
+
+genRunMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Generator Exercising function main operating mode; set to INHIBIT
+ to inhibit exercising the generator."
+ ::= { genRun 1 }
+ --1.3.6.1.4.1.3052.10.2.19.2.1
+
+genRunSched OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule number(s) which govern(s) when Generator Exercising function
+ runs."
+ ::= { genRun 2 }
+ --1.3.6.1.4.1.3052.10.2.19.2.2
+
+genRunDuration OBJECT-TYPE
+ SYNTAX Integer32 (600..3600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds that generator should run, started when the
+ generator needs to start by SCHEDULE or by being forced to start."
+ ::= { genRun 3 }
+ --1.3.6.1.4.1.3052.10.2.19.2.3
+
+genRunForce OBJECT-TYPE
+ SYNTAX Integer32 (0..1)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Write 1 to this to force the generator exercising to start. Always
+ reads as 0."
+ ::= { genRun 4 }
+ --1.3.6.1.4.1.3052.10.2.19.2.4
+
+genRunReqasm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Require ASM connectivity before starting the generator from a schedule."
+ ::= { genRun 5 }
+ --1.3.6.1.4.1.3052.10.2.19.2.5
+
+genRunStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of Generator Exercising function."
+ ::= { genRun 6 }
+ --1.3.6.1.4.1.3052.10.2.19.2.6
+
+
+genRunNonstartEventEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable generator non-start event."
+ ::= { genRunNonstartEvent 1 }
+ --1.3.6.1.4.1.3052.10.2.19.2.7.1
+
+genRunNonstartEventActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for generator non-start event."
+ ::= { genRunNonstartEvent 2 }
+ --1.3.6.1.4.1.3052.10.2.19.2.7.2
+
+genRunNonstartEventTrap OBJECT-TYPE
+ SYNTAX Integer32 (536..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for generator non-start event."
+ ::= { genRunNonstartEvent 3 }
+ --1.3.6.1.4.1.3052.10.2.19.2.7.3
+
+genRunNonstartEventClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for generator non-start event."
+ ::= { genRunNonstartEvent 4 }
+ --1.3.6.1.4.1.3052.10.2.19.2.7.4
+
+
+--***************************************************************************************
+--Calendar Section 2.20
+--***************************************************************************************
+
+schedTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScheduleConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of schedules"
+ ::= { calendar 1 }
+ --1.3.6.1.4.1.3052.10.2.20.1
+
+schedEntry OBJECT-TYPE
+ SYNTAX ScheduleConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of schedules."
+ INDEX { schedIndex }
+ ::= { schedTable 1 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1
+
+schedIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of schedules."
+ ::= { schedEntry 1 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.1
+
+schedEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable this schedule."
+ ::= { schedEntry 2 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.2
+
+schedStart OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is of the form 'mm/dd/yy hh:mm:ss'. This controls on which
+ date/time the schedule starts."
+ ::= { schedEntry 3 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.3
+
+schedRepeatMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls in which way the schedule should repeat."
+ ::= { schedEntry 4 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.4
+
+schedRepeatFreq OBJECT-TYPE
+ SYNTAX Integer32 (1..400)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls how often the schedule should repeat: every nth day, week,
+ month, or year."
+ ::= { schedEntry 5 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.5
+
+schedRepeatEndMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls how the repeating schedule should end."
+ ::= { schedEntry 6 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.6
+
+schedRepeatEndAfter OBJECT-TYPE
+ SYNTAX Integer32 (1..1000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of times this schedule should be repeated; relevant when the
+ repeat end mode is AFTER."
+ ::= { schedEntry 7 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.7
+
+schedRepeatEndOn OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Date/time (in the form 'mm/yy/dd hh:mm:ss' or blank string) after
+ which repeating should end, relevant when repeat end mode is ON DATE."
+ ::= { schedEntry 8 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.8
+
+schedRepeatWeeklySun OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule on Sunday(s); relevant when repeat mode is weekly."
+ ::= { schedEntry 9 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.9
+
+schedRepeatWeeklyMon OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule on Monday(s); relevant when repeat mode is weekly."
+ ::= { schedEntry 10 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.10
+
+schedRepeatWeeklyTue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule on Tuesday(s); relevant when repeat mode is weekly."
+ ::= { schedEntry 11 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.11
+
+schedRepeatWeeklyWed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule on Wednesday(s); relevant when repeat mode is weekly."
+ ::= { schedEntry 12 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.12
+
+schedRepeatWeeklyThu OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule on Thursday(s); relevant when repeat mode is weekly."
+ ::= { schedEntry 13 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.13
+
+schedRepeatWeeklyFri OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule on Friday(s); relevant when repeat mode is weekly."
+ ::= { schedEntry 14 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.14
+
+schedRepeatWeeklySat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule on Saturday(s); relevant when repeat mode is weekly."
+ ::= { schedEntry 15 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.15
+
+schedRepeatMonthlyMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EACH means the schedule runs on specific dates of the month. ON THE
+ means the schedule runs on calculated dates of the month according to
+ which day that month starts."
+ ::= { schedEntry 16 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.16
+
+schedRepeatMonthlyDates OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Comma-separated list of dates of a month on which this schedule should
+ run, relevant when repeat monthly mode is EACH."
+ ::= { schedEntry 17 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.17
+
+schedRepeatMonthlyOnThe OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls on which day of the month this schedule should run, relevant
+ when repeat monthly mode is ON THE."
+ ::= { schedEntry 18 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.18
+
+schedRepeatMonthlyOnDay OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls the day of week on which this schedule is run, relevant when
+ repeat monthly mode is ON THE"
+ ::= { schedEntry 19 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.19
+
+schedRepeatYearlyJan OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in January, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 20 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.20
+
+schedRepeatYearlyFeb OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in February, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 21 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.21
+
+schedRepeatYearlyMar OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in March, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 22 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.22
+
+schedRepeatYearlyApr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in April, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 23 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.23
+
+schedRepeatYearlyMay OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in May, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 24 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.24
+
+schedRepeatYearlyJun OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in June, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 25 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.25
+
+schedRepeatYearlyJul OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in July, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 26 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.26
+
+schedRepeatYearlyAug OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in August, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 27 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.27
+
+schedRepeatYearlySep OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in September, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 28 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.28
+
+schedRepeatYearlyOct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in October, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 29 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.29
+
+schedRepeatYearlyNov OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in November, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 30 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.30
+
+schedRepeatYearlyDec OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Run this schedule in December, relevant when repeat mode is YEARLY."
+ ::= { schedEntry 31 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.31
+
+schedRepeatYearlyOnThe OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls on which day of the month this schedule should run, relevant
+ when repeat mode is YEARLY."
+ ::= { schedEntry 32 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.32
+
+schedRepeatYearlyOnDay OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls the day of week on which this schedule is run, relevant when
+ repeat mode is YEARLY."
+ ::= { schedEntry 33 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.33
+
+schedNextTrigger OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When this schedule will next trigger."
+ ::= { schedEntry 34 }
+ --1.3.6.1.4.1.3052.10.2.20.1.1.34
+
+
+--***************************************************************************************
+--Product IDs Section 3
+--***************************************************************************************
+
+siteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Site Name string; Max 40 characters."
+ ::= { productIds 1 }
+ --1.3.6.1.4.1.3052.10.3.1
+
+thisProduct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is a factory configured string for the
+ product name."
+ ::= { productIds 2 }
+ --1.3.6.1.4.1.3052.10.3.2
+
+stockTrapString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The message defined for the event that triggers a trap."
+ ::= { productIds 3 }
+ --1.3.6.1.4.1.3052.10.3.3
+
+trapEventTypeNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the type of
+ event that happened. Definitions:
+ 4 Scheduled
+ 7 Serial Handshaking Low
+ 8 Serial Handshaking High
+ 10 Contact Closure Active
+ 11 Contact Closure Inactive
+ 12 Temperature High
+ 13 Temperature Very High
+ 14 Temperature Low
+ 15 Temperature Very Low
+ 16 Temperature Return to Normal
+ 17 Humidity High
+ 18 Humidity Very High
+ 19 Humidity Low
+ 20 Humidity Very Low
+ 21 Humidity Return to Normal
+ 26 Analog High
+ 27 Analog Very High
+ 28 Analog Low
+ 29 Analog Very Low
+ 30 Analog Normal
+ 40 EventSensor Unresponsive
+ 41 Custom
+ 42 CPE Down
+ 44 CPE Normal
+ 49 Fuel Sensor Disconnect
+ 50 Fuel Sensor Disconnect Return to Normal
+ 56 Fuel Sensor
+ 57 AC Power Monitor Average Voltage Very Low
+ 58 AC Power Monitor Average Voltage Low
+ 59 AC Power Monitor Average Voltage Return to Normal
+ 60 AC Power Monitor Average Voltage High
+ 61 AC Power Monitor Average Voltage Very High
+ 62 AC Power Monitor Average Current Very Low
+ 63 AC Power Monitor Average Current Low
+ 64 AC Power Monitor Average Current Return to Normal
+ 65 AC Power Monitor Average Current High
+ 66 AC Power Monitor Average Current Very High
+ 67 AC Power Monitor Frequency Very Low
+ 68 AC Power Monitor Frequency Low
+ 69 AC Power Monitor Frequency Return to Normal
+ 70 AC Power Monitor Frequency High
+ 71 AC Power Monitor Frequency Very High
+ 72 AC Power Monitor Total Real Power Very Low
+ 73 AC Power Monitor Total Real Power Low
+ 74 AC Power Monitor Total Real Power Return to Normal
+ 75 AC Power Monitor Total Real Power High
+ 76 AC Power Monitor Total Real Power Very High
+ 77 AC Power Monitor Disconnect
+ 78 AC Power Monitor Disconnect Return to Normal
+ 81 Fuel Sensor Volume Sudden Change
+ 82 Fuel Sensor Volume Slow Change
+ 83 CPE Down Reminder
+ 84 AC Power Monitor Total Power Factor Very Low
+ 85 AC Power Monitor Total Power Factor Low
+ 86 AC Power Monitor Total Power Factor Return to Normal
+ 100 Contact Closure Active Reminder
+ 101 Temperature High Reminder
+ 102 Temperature High Very Reminder
+ 103 Temperature Low Reminder
+ 104 Temperature Very Low Reminder
+ 105 Humidity High Reminder
+ 106 Humidity Very High Reminder
+ 107 Humidity Low Reminder
+ 108 Humidity Very Low Reminder
+ 109 Analog High Reminder
+ 110 Analog Very High Reminder
+ 111 Analog Low Reminder
+ 112 Analog Very Low Reminder
+ 130 Relay Output Active
+ 131 Relay Output Inactive
+ 132 Power Output On
+ 133 Power Output Off
+ 161 Camera
+ 164 Reset
+ 166 Fuel Sensor Levels Auto Adjust
+
+ "
+ ::= { productIds 4 }
+ --1.3.6.1.4.1.3052.10.3.4
+
+trapEventTypeName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the string
+ corresponding to the event type."
+ ::= { productIds 5 }
+ --1.3.6.1.4.1.3052.10.3.5
+
+trapIncludedValue OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the generic
+ included value."
+ ::= { productIds 6 }
+ --1.3.6.1.4.1.3052.10.3.6
+
+trapIncludedString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the generic
+ included string."
+ ::= { productIds 7 }
+ --1.3.6.1.4.1.3052.10.3.7
+
+trapTypeString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The cause of the trap, added for DL880 compatibility."
+ ::= { productIds 8 }
+ --1.3.6.1.4.1.3052.10.3.8
+
+trapEventClassNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the configurable
+ class number associated with the triggering event."
+ ::= { productIds 9 }
+ --1.3.6.1.4.1.3052.10.3.9
+
+trapEventClassName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the configurable
+ class name associated with the class number."
+ ::= { productIds 10 }
+ --1.3.6.1.4.1.3052.10.3.10
+
+
+--***************************************************************************************
+--Key Interface Section 4
+--***************************************************************************************
+
+keyInterface OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object represents a setting key interface. When
+ setting this object, the value to set is the 'sk' command
+ you would enter on the command line (without the 'sk'). To
+ get the result of the operation, read this object after you
+ write it.
+
+ For example, to configure EventSensor 1 contact closure 34
+ event actions to be an SNMP InformRequest to host foo, set
+ this object to:
+ 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP
+ response is the result of the operation: if setting that key
+ to that value was a success then the SNMP response will be a
+ success and the response value will be what you had set. If
+ you subsequently read this object then you will see a
+ message 'OK: ...'.
+
+ If setting that key to that value failed then the SNMP
+ response will be a failure (a badValue response). If you
+ subsequently read this object then the value returned is the
+ reason that setting that key to that value failed.
+
+ For another example, to read user 3's pass-through access
+ for port 7, set this object to:
+ 'sec.user[3].port[7].ptaccess'. The SNMP response is the
+ result of the operation: if reading that key is a success
+ then the SNMP response will be a success and the response
+ value will be what you had SET (i.e., the opertion of
+ reading a key, which is just the key itself with no '='
+ operator, and this is not the key value you want to read).
+ If you subsequently read this object then the value
+ returned is the value of the key you want to read.
+
+ If reading that key failed (e.g., if the key is invalid)
+ then the SNMP response to your SNMP set operation (the
+ value you set being the invalid key to read) will be a
+ failure (a badValue response). If you subsequently read
+ this object then the value returned is the reason that
+ reading that key failed (i.e., 'invalid key')."
+ ::= { s550 4 }
+ --1.3.6.1.4.1.3052.10.4
+
+
+--***************************************************************************************
+--TABLE DEFINITIONS
+--***************************************************************************************
+
+ESPointConfigTemp ::=
+ SEQUENCE {
+ espcTempIndexES
+ Integer32,
+ espcTempIndexPoint
+ Integer32,
+ espcTempEnable
+ DisplayString,
+ espcTempScale
+ DisplayString,
+ espcTempDeadband
+ DisplayString,
+ espcTempVHighTemp
+ DisplayString,
+ espcTempVHighActions
+ DisplayString,
+ espcTempVHighTrapnum
+ Integer32,
+ espcTempVHighClass
+ DisplayString,
+ espcTempHighTemp
+ DisplayString,
+ espcTempHighActions
+ DisplayString,
+ espcTempHighTrapnum
+ Integer32,
+ espcTempHighClass
+ DisplayString,
+ espcTempNormalActions
+ DisplayString,
+ espcTempNormalTrapnum
+ Integer32,
+ espcTempNormalClass
+ DisplayString,
+ espcTempLowTemp
+ DisplayString,
+ espcTempLowActions
+ DisplayString,
+ espcTempLowTrapnum
+ Integer32,
+ espcTempLowClass
+ DisplayString,
+ espcTempVLowTemp
+ DisplayString,
+ espcTempVLowActions
+ DisplayString,
+ espcTempVLowTrapnum
+ Integer32,
+ espcTempVLowClass
+ DisplayString,
+ espcTempGroup
+ DisplayString
+}
+
+
+ESPointConfigCC ::=
+ SEQUENCE {
+ espcCCIndexES
+ Integer32,
+ espcCCIndexPoint
+ Integer32,
+ espcCCEnable
+ DisplayString,
+ espcCCName
+ DisplayString,
+ espcCCEventState
+ DisplayString,
+ espcCCThreshold
+ Integer32,
+ espcCCEventActions
+ DisplayString,
+ espcCCEventTrapnum
+ Integer32,
+ espcCCEventClass
+ DisplayString,
+ espcCCNormalActions
+ DisplayString,
+ espcCCNormalTrapnum
+ Integer32,
+ espcCCNormalClass
+ DisplayString,
+ espcCCAlarmAlias
+ DisplayString,
+ espcCCNormalAlias
+ DisplayString,
+ espcCCNormalThreshold
+ Integer32,
+ espcCCOverrideGlobalReminder
+ DisplayString,
+ espcCCReminderInterval
+ Integer32,
+ espcCCGroup
+ DisplayString
+}
+
+ESPointConfigHumid ::=
+ SEQUENCE {
+ espcHumidIndexES
+ Integer32,
+ espcHumidIndexPoint
+ Integer32,
+ espcHumidEnable
+ DisplayString,
+ espcHumidDeadband
+ Integer32,
+ espcHumidVHighHumid
+ Integer32,
+ espcHumidVHighActions
+ DisplayString,
+ espcHumidVHighTrapnum
+ Integer32,
+ espcHumidVHighClass
+ DisplayString,
+ espcHumidHighHumid
+ Integer32,
+ espcHumidHighActions
+ DisplayString,
+ espcHumidHighTrapnum
+ Integer32,
+ espcHumidHighClass
+ DisplayString,
+ espcHumidNormalActions
+ DisplayString,
+ espcHumidNormalTrapnum
+ Integer32,
+ espcHumidNormalClass
+ DisplayString,
+ espcHumidLowHumid
+ Integer32,
+ espcHumidLowActions
+ DisplayString,
+ espcHumidLowTrapnum
+ Integer32,
+ espcHumidLowClass
+ DisplayString,
+ espcHumidVLowHumid
+ Integer32,
+ espcHumidVLowActions
+ DisplayString,
+ espcHumidVLowTrapnum
+ Integer32,
+ espcHumidVLowClass
+ DisplayString,
+ espcHumidGroup
+ DisplayString
+}
+
+ESPointConfigAnalogInput ::=
+ SEQUENCE {
+ espcAIIndexES
+ Integer32,
+ espcAIIndexPoint
+ Integer32,
+ espcAIEnable
+ DisplayString,
+ espcAIDeadband
+ DisplayString,
+ espcAIVhighValue
+ DisplayString,
+ espcAIVhighActions
+ DisplayString,
+ espcAIVhighTrapnum
+ Integer32,
+ espcAIVhighClass
+ DisplayString,
+ espcAIHighValue
+ DisplayString,
+ espcAIHighActions
+ DisplayString,
+ espcAIHighTrapnum
+ Integer32,
+ espcAIHighClass
+ DisplayString,
+ espcAINormalActions
+ DisplayString,
+ espcAINormalTrapnum
+ Integer32,
+ espcAINormalClass
+ DisplayString,
+ espcAILowValue
+ DisplayString,
+ espcAILowActions
+ DisplayString,
+ espcAILowTrapnum
+ Integer32,
+ espcAILowClass
+ DisplayString,
+ espcAIVlowValue
+ DisplayString,
+ espcAIVlowActions
+ DisplayString,
+ espcAIVlowTrapnum
+ Integer32,
+ espcAIVlowClass
+ DisplayString,
+ espcAIConvUnitName
+ DisplayString,
+ espcAIConvHighValue
+ DisplayString,
+ espcAIConvHighUnit
+ DisplayString,
+ espcAIConvLowValue
+ DisplayString,
+ espcAIConvLowUnit
+ DisplayString,
+ espcAIDisplayFormat
+ DisplayString,
+ espcAIGroup
+ DisplayString
+}
+
+
+ActionCallNumberConfig ::=
+ SEQUENCE {
+ actionCallNumberIndex
+ Integer32,
+ actionCallNumber
+ DisplayString
+
+}
+
+ActionPagerConfig ::=
+ SEQUENCE {
+ actionPagerIndex
+ Integer32,
+ actionPagerType
+ DisplayString,
+ actionPagerNumber
+ DisplayString,
+ actionPagerID
+ DisplayString,
+ actionPagerMessage
+ DisplayString,
+ actionPagerPostCalloutDelay
+ Integer32,
+ actionPagerPostIDDelay
+ Integer32
+}
+
+ESPointConfigOutput ::=
+ SEQUENCE {
+ espcOutputIndexES
+ Integer32,
+ espcOutputIndexPoint
+ Integer32,
+ espcOutputEnable
+ DisplayString,
+ espcOutputActiveState
+ DisplayString,
+ espcOutputType
+ DisplayString,
+ espcOutputAliasValue
+ DisplayString,
+ espcOutputAliasColor
+ DisplayString,
+ espcOutputActiveAlias
+ DisplayString,
+ espcOutputActiveColor
+ DisplayString,
+ espcOutputActiveActions
+ DisplayString,
+ espcOutputActiveTrapnum
+ Integer32,
+ espcOutputActiveClass
+ DisplayString,
+ espcOutputInactiveAlias
+ DisplayString,
+ espcOutputInactiveColor
+ DisplayString,
+ espcOutputInactiveActions
+ DisplayString,
+ espcOutputInactiveTrapnum
+ Integer32,
+ espcOutputInactiveClass
+ DisplayString,
+ espcOutputGroup
+ DisplayString
+}
+
+EventClassConfig ::=
+ SEQUENCE {
+ evClassNameIndex
+ Integer32,
+ evClassName
+ DisplayString
+}
+
+RTSFileConfig ::=
+ SEQUENCE {
+ rtsFileIndex
+ Integer32,
+ rtsFileMode
+ DisplayString,
+ rtsFileShowAnswer
+ DisplayString,
+ rtsFileReqXON
+ DisplayString,
+ rtsFileTimeout
+ Integer32,
+ rtsFileEmptyClose
+ DisplayString,
+ rtsFilePushHost
+ DisplayString,
+ rtsFilePushPort
+ Integer32,
+ rtsFilePushRetryTimer
+ Integer32
+}
+
+
+ModemCLIDLogConfig ::=
+ SEQUENCE {
+ modemCLIDLogIndex
+ Integer32,
+ modemCLIDLogNumber
+ DisplayString
+}
+
+CPEConfig ::=
+ SEQUENCE {
+ cpeIndex
+ Integer32,
+ cpeHost
+ DisplayString,
+ cpeName
+ DisplayString,
+ cpeDescription
+ DisplayString,
+ cpeKeepalive
+ Integer32,
+ cpeThreshold
+ Integer32,
+ cpeEventReminderInterval
+ Integer32,
+ cpeKeepaliveTicks
+ Integer32,
+ cpePingSize
+ Integer32,
+ cpeInfoReset
+ Integer32,
+ cpeInfoNumReq
+ Integer32,
+ cpeInfoNumGoodResp
+ Integer32,
+ cpeInfoNumBadResp
+ Integer32,
+ cpeInfoNumLostResp
+ Integer32,
+ cpeInfoPercentLoss
+ DisplayString,
+ cpeInfoPercentBad
+ DisplayString
+}
+
+ScriptingConfig ::=
+ SEQUENCE {
+ scrIndex
+ Integer32,
+ scrEnable
+ DisplayString,
+ scrName
+ DisplayString,
+ scrFilename
+ DisplayString,
+ scrRunAlways
+ DisplayString,
+ scrRunAtStartup
+ DisplayString,
+ scrRunScheduled
+ DisplayString,
+ scrScheduleTime
+ DisplayString,
+ scrArguments
+ DisplayString,
+ scrRepeatInterval
+ Integer32
+}
+
+ScriptingDTRCtrlPortEnableConfig ::=
+ SEQUENCE {
+ scrDTRCtrlPortEnableIndex
+ Integer32,
+ scrDTRCtrlPortEnable
+ DisplayString
+
+}
+
+ScriptingVolatileString ::=
+ SEQUENCE {
+ scrVolatileStringIndex
+ Integer32,
+ scrVolatileString
+ DisplayString
+}
+
+ScriptingVolatileInt ::=
+ SEQUENCE {
+ scrVolatileIntIndex
+ Integer32,
+ scrVolatileInt
+ Integer32
+}
+
+ScriptingNonVolatileString ::=
+ SEQUENCE {
+ scrNonVolatileStringIndex
+ Integer32,
+ scrNonVolatileString
+ DisplayString
+}
+
+ScriptingNonVolatileInt ::=
+ SEQUENCE {
+ scrNonVolatileIntIndex
+ Integer32,
+ scrNonVolatileInt
+ Integer32
+}
+
+GenSetRelaySequence ::=
+ SEQUENCE {
+ genSetRelayTableIndex
+ Integer32,
+ genSetRelayTableEnable
+ DisplayString,
+ genSetRelayTableEs
+ Integer32,
+ genSetRelayTablePoint
+ Integer32,
+ genSetRelayTableRunningstate
+ DisplayString
+}
+
+CRDBFileEnforceMinConfig ::=
+ SEQUENCE {
+ sysCRDBFileEnforceMinIndex
+ Integer32,
+ sysCRDBFileEnforceMin
+ DisplayString
+}
+
+CRDBFileIDConfig ::=
+ SEQUENCE {
+ sysCRDBFileIDIndex
+ Integer32,
+ sysCRDBFileID
+ DisplayString
+}
+
+NetworkTimeHostConfig ::=
+ SEQUENCE {
+ sysTimeNetHostIndex
+ Integer32,
+ sysTimeNetHost
+ DisplayString
+}
+
+ActionHostConfig ::=
+ SEQUENCE {
+ actionHostIndex
+ Integer32,
+ actionHost
+ DisplayString
+}
+
+ActionEmailConfig ::=
+ SEQUENCE {
+ actionEmailIndex
+ Integer32,
+ actionEmail
+ DisplayString
+}
+
+FileEnforceMinimumConfig ::=
+ SEQUENCE {
+ sysCRDBFileEnforceMinIndex
+ Integer32,
+ sysCRDBFileEnforceMin
+ DisplayString
+}
+
+SerialHandshakingLowEventConfig ::=
+ SEQUENCE {
+ evShskLowIndex
+ Integer32,
+ evShskLowEnable
+ DisplayString,
+ evShskLowActions
+ DisplayString,
+ evShskLowMessage
+ DisplayString,
+ evShskLowClass
+ DisplayString,
+ evShskLowTrapNum
+ Integer32
+}
+
+SerialHandshakingHighEventConfig ::=
+ SEQUENCE {
+ evShskHighIndex
+ Integer32,
+ evShskHighEnable
+ DisplayString,
+ evShskHighActions
+ DisplayString,
+ evShskHighMessage
+ DisplayString,
+ evShskHighClass
+ DisplayString,
+ evShskHighTrapNum
+ Integer32
+}
+
+NoDataEvent1PortEnableConfig ::=
+ SEQUENCE {
+ evNoData1PortEnableIndex
+ Integer32,
+ evNoData1PortEnable
+ DisplayString
+}
+
+NoDataEvent2PortEnableConfig ::=
+ SEQUENCE {
+ evNoData2PortEnableIndex
+ Integer32,
+ evNoData2PortEnable
+ DisplayString
+}
+
+DataEventMacroConfig ::=
+ SEQUENCE {
+ evdMacroIndex
+ Integer32,
+ evdMacroName
+ DisplayString,
+ evdMacroEquation
+ DisplayString
+}
+
+DataEventFieldConfig ::=
+ SEQUENCE {
+ evdFieldIndex
+ Integer32,
+ evdFieldStart
+ Integer32,
+ evdFieldLength
+ Integer32,
+ evdFieldName
+ DisplayString,
+ evdFieldLine
+ Integer32,
+ evdFieldType
+ DisplayString
+}
+
+DataEventConfig ::=
+ SEQUENCE {
+ evdIndex
+ Integer32,
+ evdEnable
+ DisplayString,
+ evdName
+ DisplayString,
+ evdEquation
+ DisplayString,
+ evdThreshold
+ Integer32,
+ evdAutoClear
+ DisplayString,
+ evdClearInterval
+ DisplayString,
+ evdClearTime
+ DisplayString,
+ evdActions
+ DisplayString,
+ evdClass
+ DisplayString,
+ evdTrapNum
+ Integer32,
+ evdMode
+ DisplayString
+}
+
+SecUserConfig ::=
+ SEQUENCE {
+ secUserIndex
+ Integer32,
+ secUserEnable
+ DisplayString,
+ secUserConnectVia
+ DisplayString,
+ secUserLoginTo
+ DisplayString,
+ secUserAccessFile
+ DisplayString,
+ secUserPTEscapeTo
+ DisplayString,
+ secUserPPPType
+ DisplayString,
+ secUserRights
+ DisplayString,
+ secUserEventsReadAccess
+ DisplayString,
+ secUserAuditReadAccess
+ DisplayString,
+ secUserEventsWriteAccess
+ DisplayString,
+ secUserAuditWriteAccess
+ DisplayString,
+ secUserExpiration
+ DisplayString,
+ secUserCallbackNumber1
+ DisplayString,
+ secUserCallbackNumber2
+ DisplayString,
+ secUserCallbackNumber3
+ DisplayString,
+ secUserChallengeTelnetMode
+ DisplayString,
+ secUserChallengeModemMode
+ DisplayString,
+ secUserChallengeConsoleMode
+ DisplayString,
+ secUserChallengeTelnetSendTo
+ DisplayString,
+ secUserChallengeModemSendTo
+ DisplayString,
+ secUserChallengeExpiration
+ Integer32
+}
+
+
+
+
+ModemCLIDNumberConfig ::=
+ SEQUENCE {
+ modemCLIDNumberIndex
+ Integer32,
+ modemCLIDNumber
+ DisplayString
+}
+
+
+RouteTestConfig ::=
+ SEQUENCE {
+ routeTestAddressIndex
+ Integer32,
+ routeTestAddress
+ DisplayString
+}
+
+IPRestrictionConfig ::=
+ SEQUENCE {
+ ipRestrictionIndex
+ Integer32,
+ ipRestrictionEnable
+ DisplayString,
+ ipRestrictionMask
+ DisplayString
+}
+
+DNSConfig ::=
+ SEQUENCE {
+ dnsIndex
+ Integer32,
+ dnsAddress
+ IpAddress
+}
+
+HostConfig ::=
+ SEQUENCE {
+ hostIndex
+ Integer32,
+ hostDeclaration
+ DisplayString
+}
+
+SNMPProxyTable ::=
+ SEQUENCE {
+ snmpProxyIndex
+ Integer32,
+ snmpProxyEgressOIDBranch
+ DisplayString,
+ snmpProxyIP
+ DisplayString,
+ snmpProxyPort
+ Integer32,
+ snmpProxyIngressOIDBranch
+ DisplayString,
+ snmpProxyName
+ DisplayString
+}
+
+SNMPPollRequestConfig ::=
+ SEQUENCE {
+ snmpPRequestIndex
+ Integer32,
+ snmpPRequestDescription
+ DisplayString,
+ snmpPRequestAgent
+ DisplayString,
+ snmpPRequestReadcom
+ DisplayString,
+ snmpPRequestOID
+ DisplayString,
+ snmpPRequestPeriod
+ Integer32,
+ snmpPRequestID
+ DisplayString,
+ snmpPRequestThreshold
+ DisplayString,
+ snmpPRequestResultStatus
+ DisplayString,
+ snmpPRequestResultValue
+ DisplayString,
+ snmpPRequestResultTime
+ DisplayString,
+ snmpPRequestResultType
+ DisplayString
+}
+
+FTPPushPushFileConfig ::=
+ SEQUENCE {
+ ftpPushPushFileIndex
+ Integer32,
+ ftpPushPushFile
+ DisplayString
+}
+
+FTPPushRemoteFileConfig ::=
+ SEQUENCE {
+ ftpPushRemoteFileIndex
+ Integer32,
+ ftpPushRemoteFileName
+ DisplayString
+}
+
+PortConfig ::=
+ SEQUENCE {
+ portConfigIndex
+ Integer32,
+ portConfigBaud
+ Integer32,
+ portConfigDataFormat
+ Integer32,
+ portConfigStripPtOutputLfs
+ Integer32,
+ portConfigStripPtInputLfs
+ Integer32,
+ portConfigMaskEnable
+ Integer32,
+ portConfigDAEnable
+ Integer32,
+ portConfigStoreAlarmsDPT
+ DisplayString,
+ portConfigRecordTimeout
+ Integer32,
+ portConfigDataType
+ DisplayString,
+ portConfigEtxToCRLF
+ DisplayString,
+ portConfigMLREnable
+ DisplayString,
+ portConfigMLRStartField1Pos
+ Integer32,
+ portConfigMLRStartField1Text
+ DisplayString,
+ portConfigMLRStartField2Pos
+ Integer32,
+ portConfigMLRStartField2Text
+ DisplayString,
+ portConfigMLRNumLinesBefore
+ Integer32,
+ portConfigMLREndDetection
+ DisplayString,
+ portConfigMLRLineCount
+ Integer32,
+ portConfigMLREndField1Pos
+ Integer32,
+ portConfigMLREndField1Text
+ DisplayString,
+ portConfigMLREndField2Pos
+ Integer32,
+ portConfigMLREndField2Text
+ DisplayString,
+ portConfigMLRUseComplexRules
+ DisplayString,
+ portConfigBufferPT
+ DisplayString,
+ portConfigId
+ DisplayString,
+ portConfigMode
+ DisplayString,
+ portConfigHsk
+ DisplayString
+
+}
+
+ESPoint ::=
+ SEQUENCE {
+ esIndexES
+ Integer32,
+ esIndexPC
+ Integer32,
+ esIndexPoint
+ Integer32,
+ esPointName
+ DisplayString,
+ esPointInEventState
+ Integer32,
+ esPointValueInt
+ Integer32,
+ esPointValueStr
+ DisplayString,
+ esPointTimeLastChange
+ DisplayString,
+ esPointTimetickLastChange
+ TimeTicks,
+ esPointAliasValueStr
+ DisplayString,
+ esPointClassValueStr
+ DisplayString
+}
+
+ESExist ::=
+ SEQUENCE {
+ esIndex
+ Integer32,
+ esName
+ DisplayString,
+ esID
+ DisplayString,
+ esNumberTempSensors
+ Integer32,
+ esTempReportingMode
+ DisplayString,
+ esNumberCCs
+ Integer32,
+ esCCReportingMode
+ DisplayString,
+ esNumberHumidSensors
+ Integer32,
+ esHumidReportingMode
+ DisplayString,
+ esNumberNoiseSensors
+ Integer32,
+ esNoiseReportingMode
+ DisplayString,
+ esNumberAirflowSensors
+ Integer32,
+ esAirflowReportingMode
+ DisplayString,
+ esNumberAnalog
+ Integer32,
+ esAnalogReportingMode
+ DisplayString,
+ esNumberOutputs
+ Integer32,
+ esOutputReportingMode
+ DisplayString,
+ esTempCombinedStatus
+ DisplayString,
+ esCCCombinedStatusBlock1
+ DisplayString,
+ esCCCombinedStatusBlock2
+ DisplayString,
+ esCCCombinedStatusBlock3
+ DisplayString,
+ esCCCombinedStatusBlock4
+ DisplayString,
+ esCCCombinedStatusBlock5
+ DisplayString,
+ esCCCombinedStatusBlock6
+ DisplayString,
+ esCCCombinedStatusBlock7
+ DisplayString,
+ esCCCombinedStatusBlock8
+ DisplayString,
+ esHumidCombinedStatus
+ DisplayString,
+ esAnalogCombinedStatusBlock1
+ DisplayString,
+ esAnalogCombinedStatusBlock2
+ DisplayString,
+ esAnalogCombinedStatusBlock3
+ DisplayString,
+ esAnalogCombinedStatusBlock4
+ DisplayString,
+ esAnalogCombinedStatusBlock5
+ DisplayString,
+ esAnalogCombinedStatusBlock6
+ DisplayString,
+ esOutputCombinedStatusBlock1
+ DisplayString,
+ esOutputCombinedStatusBlock2
+ DisplayString
+}
+
+DEStatus ::=
+ SEQUENCE {
+ deStatusIndex
+ Integer32,
+ deStatusName
+ DisplayString,
+ deStatusCounter
+ Integer32,
+ deStatusThreshold
+ Integer32
+}
+
+FSStatus ::=
+ SEQUENCE {
+ fsStatusIndex
+ Integer32,
+ fsStatusName
+ DisplayString,
+ fsStatusDeviceState
+ DisplayString,
+ fsStatusVolumeValueString
+ DisplayString,
+ fsStatusVolumePercentLevel
+ DisplayString,
+ fsStatusVolumeInEventState
+ DisplayString,
+ fsStatusCombined
+ DisplayString
+}
+
+ACPMStatus ::=
+ SEQUENCE {
+ acpmsIndex
+ Integer32,
+ acpmsName
+ DisplayString,
+ acpmsAvgVoltageValueStr
+ DisplayString,
+ acpmsAvgVoltageMinStr
+ DisplayString,
+ acpmsAvgVoltageMaxStr
+ DisplayString,
+ acpmsAvgVoltageAvgStr
+ DisplayString,
+ acpmsAvgVoltageInEventState
+ DisplayString,
+ acpmsVoltagePhaseAValueStr
+ DisplayString,
+ acpmsVoltagePhaseBValueStr
+ DisplayString,
+ acpmsVoltagePhaseCValueStr
+ DisplayString,
+ acpmsAvgCurrentValueStr
+ DisplayString,
+ acpmsAvgCurrentMinStr
+ DisplayString,
+ acpmsAvgCurrentMaxStr
+ DisplayString,
+ acpmsAvgCurrentAvgStr
+ DisplayString,
+ acpmsAvgCurrentInEventState
+ DisplayString,
+ acpmsCurrentPhaseAValueStr
+ DisplayString,
+ acpmsCurrentPhaseBValueStr
+ DisplayString,
+ acpmsCurrentPhaseCValueStr
+ DisplayString,
+ acpmsVoltageL1L2Value
+ DisplayString,
+ acpmsVoltageL2L3Value
+ DisplayString,
+ acpmsVoltageL3L1Value
+ DisplayString,
+ acpmsAvgFreqValueStr
+ DisplayString,
+ acpmsAvgFreqMinStr
+ DisplayString,
+ acpmsAvgFreqMaxStr
+ DisplayString,
+ acpmsAvgFreqAvgStr
+ DisplayString,
+ acpmsAvgFreqInEventState
+ DisplayString,
+ acpmsTRPValueStr
+ DisplayString,
+ acpmsTRPMinStr
+ DisplayString,
+ acpmsTRPMaxStr
+ DisplayString,
+ acpmsTRPAvgStr
+ DisplayString,
+ acpmsTRPInEventState
+ DisplayString,
+ acpmsRPPhaseAValueStr
+ DisplayString,
+ acpmsRPPhaseBValueStr
+ DisplayString,
+ acpmsRPPhaseCValueStr
+ DisplayString,
+ acpmsCombined
+ DisplayString,
+ acpmsTPFValueStr
+ DisplayString,
+ acpmsTPFMinStr
+ DisplayString,
+ acpmsTPFMaxStr
+ DisplayString,
+ acpmsTPFAvgStr
+ DisplayString,
+ acpmsTPFInEventState
+ DisplayString,
+ acpmsPFPhaseAValueStr
+ DisplayString,
+ acpmsPFPhaseBValueStr
+ DisplayString,
+ acpmsPFPhaseCValueStr
+ DisplayString,
+ acpmsTRcPValueStr
+ DisplayString,
+ acpmsTRcPMinStr
+ DisplayString,
+ acpmsTRcPMaxStr
+ DisplayString,
+ acpmsTRcPAvgStr
+ DisplayString,
+ acpmsRcPPhaseAValueStr
+ DisplayString,
+ acpmsRcPPhaseBValueStr
+ DisplayString,
+ acpmsRcPPhaseCValueStr
+ DisplayString,
+ acpmsTAPValueStr
+ DisplayString,
+ acpmsTAPMinStr
+ DisplayString,
+ acpmsTAPMaxStr
+ DisplayString,
+ acpmsTAPAvgStr
+ DisplayString,
+ acpmsAPPhaseAValueStr
+ DisplayString,
+ acpmsAPPhaseBValueStr
+ DisplayString,
+ acpmsAPPhaseCValueStr
+ DisplayString,
+ acpmsTotalEnergyWh
+ Integer32,
+ acpmsTotalEnergyVAR
+ Integer32,
+ acpmsTotalEnergyVA
+ Integer32,
+ acmpsAvgVoltageAlarmDatetime
+ DisplayString,
+ acmpsAvgCurrentAlarmDatetime
+ DisplayString,
+ acmpsFreqAlarmDatetime
+ DisplayString,
+ acmpsRealPowerAlarmDatetime
+ DisplayString,
+ acmpsPowerFactorAlarmDatetime
+ DisplayString
+}
+
+HVACStatusAsentriaSequence ::=
+ SEQUENCE {
+ evHVACStatusAsentriaSequenceIndex
+ Integer32,
+ evHVACStatusAsentriaSeqVentTime
+ DisplayString,
+ evHVACStatusAsentriaSeqCoolTime
+ DisplayString,
+ evHVACStatusAsentriaSeqHeatTime
+ DisplayString,
+ evHVACStatusAsentriaSeqIdleTime
+ DisplayString
+}
+
+HVACStatusAsentriaUnit ::=
+ SEQUENCE {
+ evHVACStatusAsentriaUnitIndex
+ Integer32,
+ evHVACStatusAsentriaUnitState
+ DisplayString,
+ evHVACStatusAsentriaUnitVentTime
+ DisplayString,
+ evHVACStatusAsentriaUnitCoolTime
+ DisplayString,
+ evHVACStatusAsentriaUnitHeatTime
+ DisplayString,
+ evHVACStatusAsentriaUnitIdleTime
+ DisplayString
+}
+
+HVACStatusAirsysAlarmUnit ::=
+ SEQUENCE {
+ evHVACStatusAirsysAlarmUnitIndex
+ Integer32,
+ evHVACStatusAirsysAlarmUnitLowPress
+ DisplayString,
+ evHVACStatusAirsysAlarmUnitHighPress
+ DisplayString,
+ evHVACStatusAirsysAlarmUnitEvapFan
+ DisplayString,
+ evHVACStatusAirsysAlarmUnitDirty
+ DisplayString,
+ evHVACStatusAirsysAlarmUnitDamper
+ DisplayString,
+ evHVACStatusAirsysAlarmUnitSupProbe
+ DisplayString
+}
+
+HVACStatusAirsysUnit ::=
+ SEQUENCE {
+ evHVACStatusAirsysUnitIndex
+ Integer32,
+ evHVACStatusAirsysUnitTempSupply
+ DisplayString,
+ evHVACStatusAirsysUnitFanspeed
+ DisplayString,
+ evHVACStatusAirsysUnitFreeOpening
+ DisplayString,
+ evHVACStatusAirsysUnitStatus
+ DisplayString,
+ evHVACStatusAirsysUnitLocked
+ DisplayString,
+ evHVACStatusAirsysUnitCompressor
+ DisplayString,
+ evHVACStatusAirsysUnitHeater
+ DisplayString,
+ evHVACStatusAirsysURuntimeSupplyFan
+ DisplayString,
+ evHVACStatusAirsysURuntimeCompressor
+ DisplayString,
+ evHVACStatusAirsysURuntimeHeat
+ DisplayString,
+ evHVACStatusAirsysURuntimeFreeCooling
+ DisplayString,
+ evHVACStatusAirsysUCountSupplyFan
+ DisplayString,
+ evHVACStatusAirsysUCountCompressor
+ DisplayString,
+ evHVACStatusAirsysUCountHeat
+ DisplayString,
+ evHVACStatusAirsysUCountFreeCooling
+ DisplayString
+}
+
+HVACAsentriaSensorList ::=
+ SEQUENCE {
+ evHVACAsentriaSensorListIndex
+ Integer32,
+ evHVACAsentriaSensorListES
+ DisplayString,
+ evHVACAsentriaSensorListPT
+ Integer32,
+ evHVACAsentriaSensorListType
+ DisplayString,
+ evHVACAsentriaSensorListLoc
+ DisplayString
+}
+
+HVACAsentriaUnit ::=
+ SEQUENCE {
+ evHVACAsentriaUnitIndex
+ Integer32,
+ evHVACAsentriaUnitEnable
+ DisplayString,
+ evHVACAsentriaUnitFanRelayES
+ DisplayString,
+ evHVACAsentriaUnitFanRelayPT
+ Integer32,
+ evHVACAsentriaUnitVentRelayES
+ DisplayString,
+ evHVACAsentriaUnitVentRelayPT
+ Integer32,
+ evHVACAsentriaUnitTimereset
+ Integer32,
+ evHVACAsentriaSeqTimereset
+ Integer32,
+ evHVACAsentriaUnitStage1CoolES
+ DisplayString,
+ evHVACAsentriaUnitStage1CoolPT
+ Integer32,
+ evHVACAsentriaUnitStage1HeatES
+ DisplayString,
+ evHVACAsentriaUnitStage1HeatPT
+ Integer32,
+ evHVACAsentriaUnitStage2CoolES
+ DisplayString,
+ evHVACAsentriaUnitStage2CoolPT
+ Integer32,
+ evHVACAsentriaUnitStage2HeatES
+ DisplayString,
+ evHVACAsentriaUnitStage2HeatPT
+ Integer32
+}
+
+HVACAirsysUnit::=
+ SEQUENCE {
+ evHVACAirsysUnitIndex
+ Integer32,
+ evHVACAirsysULowPEnable
+ DisplayString,
+ evHVACAirsysULowPActions
+ DisplayString,
+ evHVACAirsysULowPTrapnum
+ Integer32,
+ evHVACAirsysULowPClass
+ DisplayString,
+ evHVACAirsysULowPNormActions
+ DisplayString,
+ evHVACAirsysULowPNormTrapNum
+ Integer32,
+ evHVACAirsysULowPNormClass
+ DisplayString,
+ evHVACAirsysUHighPEnable
+ DisplayString,
+ evHVACAirsysUHighPActions
+ DisplayString,
+ evHVACAirsysUHighPTrapnum
+ Integer32,
+ evHVACAirsysUHighPClass
+ DisplayString,
+ evHVACAirsysUHighPNormActions
+ DisplayString,
+ evHVACAirsysUHighPNormTrapNum
+ Integer32,
+ evHVACAirsysUHighPNormClass
+ DisplayString,
+ evHVACAirsysUEvapFanEnable
+ DisplayString,
+ evHVACAirsysUEvapFanActions
+ DisplayString,
+ evHVACAirsysUEvapFanTrapnum
+ Integer32,
+ evHVACAirsysUEvapFanClass
+ DisplayString,
+ evHVACAirsysUEvapFanNormActions
+ DisplayString,
+ evHVACAirsysUEvapFanNormTrapNum
+ Integer32,
+ evHVACAirsysUEvapFanNormClass
+ DisplayString,
+ evHVACAirsysUDirtyEnable
+ DisplayString,
+ evHVACAirsysUDirtyActions
+ DisplayString,
+ evHVACAirsysUDirtyTrapnum
+ Integer32,
+ evHVACAirsysUDirtyClass
+ DisplayString,
+ evHVACAirsysUDirtyNormActions
+ DisplayString,
+ evHVACAirsysUDirtyNormTrapNum
+ Integer32,
+ evHVACAirsysUDirtyNormClass
+ DisplayString,
+ evHVACAirsysUInProbeEnable
+ DisplayString,
+ evHVACAirsysUInProbeActions
+ DisplayString,
+ evHVACAirsysUInProbeTrapnum
+ Integer32,
+ evHVACAirsysUInProbeClass
+ DisplayString,
+ evHVACAirsysUInProbeNormActions
+ DisplayString,
+ evHVACAirsysUInProbeNormTrapNum
+ Integer32,
+ evHVACAirsysUInProbeNormClass
+ DisplayString,
+ evHVACAirsysUDamperEnable
+ DisplayString,
+ evHVACAirsysUDamperActions
+ DisplayString,
+ evHVACAirsysUDamperTrapnum
+ Integer32,
+ evHVACAirsysUDamperClass
+ DisplayString,
+ evHVACAirsysUDamperNormActions
+ DisplayString,
+ evHVACAirsysUDamperNormTrapNum
+ Integer32,
+ evHVACAirsysUDamperNormClass
+ DisplayString,
+ evHVACAirsysUSupProbeEnable
+ DisplayString,
+ evHVACAirsysUSupProbeActions
+ DisplayString,
+ evHVACAirsysUSupProbeTrapnum
+ Integer32,
+ evHVACAirsysUSupProbeClass
+ DisplayString,
+ evHVACAirsysUSupProbeNormActions
+ DisplayString,
+ evHVACAirsysUSupProbeNormTrapNum
+ Integer32,
+ evHVACAirsysUSupProbeNormClass
+ DisplayString
+}
+
+ScheduleConfig ::=
+ SEQUENCE {
+ schedIndex
+ Integer32,
+ schedEnable
+ DisplayString,
+ schedStart
+ DisplayString,
+ schedRepeatMode
+ DisplayString,
+ schedRepeatFreq
+ Integer32,
+ schedRepeatEndMode
+ DisplayString,
+ schedRepeatEndAfter
+ Integer32,
+ schedRepeatEndOn
+ DisplayString,
+ schedRepeatWeeklySun
+ DisplayString,
+ schedRepeatWeeklyMon
+ DisplayString,
+ schedRepeatWeeklyTue
+ DisplayString,
+ schedRepeatWeeklyWed
+ DisplayString,
+ schedRepeatWeeklyThu
+ DisplayString,
+ schedRepeatWeeklyFri
+ DisplayString,
+ schedRepeatWeeklySat
+ DisplayString,
+ schedRepeatMonthlyMode
+ DisplayString,
+ schedRepeatMonthlyDates
+ DisplayString,
+ schedRepeatMonthlyOnThe
+ DisplayString,
+ schedRepeatMonthlyOnDay
+ DisplayString,
+ schedRepeatYearlyJan
+ DisplayString,
+ schedRepeatYearlyFeb
+ DisplayString,
+ schedRepeatYearlyMar
+ DisplayString,
+ schedRepeatYearlyApr
+ DisplayString,
+ schedRepeatYearlyMay
+ DisplayString,
+ schedRepeatYearlyJun
+ DisplayString,
+ schedRepeatYearlyJul
+ DisplayString,
+ schedRepeatYearlyAug
+ DisplayString,
+ schedRepeatYearlySep
+ DisplayString,
+ schedRepeatYearlyOct
+ DisplayString,
+ schedRepeatYearlyNov
+ DisplayString,
+ schedRepeatYearlyDec
+ DisplayString,
+ schedRepeatYearlyOnThe
+ DisplayString,
+ schedRepeatYearlyOnDay
+ DisplayString,
+ schedNextTrigger
+ DisplayString
+}
+
+FuelSensorConfigGeneral ::=
+ SEQUENCE {
+ fsGenIndex
+ Integer32,
+ fsGenName
+ DisplayString,
+ fsGenSensorType
+ DisplayString,
+ fsGenDistanceUnit
+ DisplayString,
+ fsGenRawValueTop
+ DisplayString,
+ fsGenTopOffset
+ DisplayString,
+ fsGenRawValueBottom
+ DisplayString,
+ fsGenBottomOffset
+ DisplayString,
+ fsGenInputES
+ Integer32,
+ fsGenInputPoint
+ Integer32,
+ fsGenFilterAveraging
+ Integer32,
+ fsGenSysrepEnable
+ DisplayString,
+ fsGenSysrepThreshold
+ DisplayString,
+ fsGenSysrepLimit
+ Integer32,
+ fsGenSysrepPackage
+ Integer32,
+ fsGenGroup
+ DisplayString,
+ fsGenEnable
+ DisplayString,
+ fsGenFuelType
+ DisplayString
+}
+
+FuelSensorConfigTank ::=
+ SEQUENCE {
+ fsTankIndex
+ Integer32,
+ fsTankHeight
+ DisplayString,
+ fsTankDimA
+ DisplayString,
+ fsTankDimB
+ DisplayString,
+ fsTankVolume
+ DisplayString,
+ fsTankVolumeUnit
+ DisplayString,
+ fsTankShape
+ DisplayString
+}
+
+FuelSensorConfigCustomTankStrapping ::=
+ SEQUENCE {
+ fsCustomTankIndexFS
+ Integer32,
+ fsCustomTankIndexDatum
+ Integer32,
+ fsCustomTankHeight
+ DisplayString,
+ fsCustomTankVolume
+ DisplayString
+}
+
+FuelSensorConfigVolume ::=
+ SEQUENCE {
+ fsVolumeIndex
+ Integer32,
+ fsVolumeEnable
+ DisplayString,
+ fsVolumeDeadband
+ DisplayString,
+ fsVolumeVHighValue
+ DisplayString,
+ fsVolumeVHighActions
+ DisplayString,
+ fsVolumeVHighTrapNum
+ Integer32,
+ fsVolumeVHighClass
+ DisplayString,
+ fsVolumeHighValue
+ DisplayString,
+ fsVolumeHighActions
+ DisplayString,
+ fsVolumeHighTrapNum
+ Integer32,
+ fsVolumeHighClass
+ DisplayString,
+ fsVolumeNormalActions
+ DisplayString,
+ fsVolumeNormalTrapNum
+ Integer32,
+ fsVolumeNormalClass
+ DisplayString,
+ fsVolumeLowValue
+ DisplayString,
+ fsVolumeLowActions
+ DisplayString,
+ fsVolumeLowTrapNum
+ Integer32,
+ fsVolumeLowClass
+ DisplayString,
+ fsVolumeVLowValue
+ DisplayString,
+ fsVolumeVLowActions
+ DisplayString,
+ fsVolumeVLowTrapNum
+ Integer32,
+ fsVolumeVLowClass
+ DisplayString
+}
+
+FuelSensorConfigDisconnect ::=
+ SEQUENCE {
+ fsDiscIndex
+ Integer32,
+ fsDiscEnable
+ DisplayString,
+ fsDiscHighValue
+ DisplayString,
+ fsDiscLowValue
+ DisplayString,
+ fsDiscActions
+ DisplayString,
+ fsDiscTrapNum
+ Integer32,
+ fsDiscClass
+ DisplayString,
+ fsDiscNormalActions
+ DisplayString,
+ fsDiscNormalTrapNum
+ Integer32,
+ fsDiscNormalClass
+ DisplayString
+}
+
+FuelSensorConfigSuddenChange ::=
+ SEQUENCE {
+ fsSuddenChangeIndex
+ Integer32,
+ fsSuddenChangeEnable
+ DisplayString,
+ fsSuddenChangeTime
+ Integer32,
+ fsSuddenChangeAmplitude
+ DisplayString,
+ fsSuddenChangeActions
+ DisplayString,
+ fsSuddenChangeTrapNum
+ Integer32,
+ fsSuddenChangeClass
+ DisplayString
+}
+
+FuelSensorConfigSlowChange ::=
+ SEQUENCE {
+ fsSlowChangeIndex
+ Integer32,
+ fsSlowChangeEnable
+ DisplayString,
+ fsSlowChangeTime
+ Integer32,
+ fsSlowChangeAmplitude
+ DisplayString,
+ fsSlowChangeActions
+ DisplayString,
+ fsSlowChangeTrapNum
+ Integer32,
+ fsSlowChangeClass
+ DisplayString
+}
+
+ACPMConfigGeneral ::=
+ SEQUENCE {
+ acpmGenIndex
+ Integer32,
+ acpmGenDevice
+ DisplayString,
+ acpmGenName
+ DisplayString,
+ acpmGenAddress
+ Integer32,
+ acpmGenPtRatio
+ Integer32,
+ acpmGenCtRatio
+ Integer32,
+ acpmGenPowerType
+ DisplayString,
+ acpmGenSysrepPackage
+ Integer32,
+ acpmGenGroup
+ DisplayString,
+ acpmGenEnable
+ DisplayString
+}
+
+ACPMConfigAvgVoltage ::=
+ SEQUENCE {
+ acpmAvgVoltageIndex
+ Integer32,
+ acpmAvgVoltageEnable
+ DisplayString,
+ acpmAvgVoltageDeadband
+ DisplayString,
+ acpmAvgVoltageVHighValue
+ DisplayString,
+ acpmAvgVoltageVHighActions
+ DisplayString,
+ acpmAvgVoltageVHighTrapNum
+ Integer32,
+ acpmAvgVoltageVHighClass
+ DisplayString,
+ acpmAvgVoltageHighValue
+ DisplayString,
+ acpmAvgVoltageHighActions
+ DisplayString,
+ acpmAvgVoltageHighTrapNum
+ Integer32,
+ acpmAvgVoltageHighClass
+ DisplayString,
+ acpmAvgVoltageNormalActions
+ DisplayString,
+ acpmAvgVoltageNormalTrapNum
+ Integer32,
+ acpmAvgVoltageNormalClass
+ DisplayString,
+ acpmAvgVoltageLowValue
+ DisplayString,
+ acpmAvgVoltageLowActions
+ DisplayString,
+ acpmAvgVoltageLowTrapNum
+ Integer32,
+ acpmAvgVoltageLowClass
+ DisplayString,
+ acpmAvgVoltageVLowValue
+ DisplayString,
+ acpmAvgVoltageVLowActions
+ DisplayString,
+ acpmAvgVoltageVLowTrapNum
+ Integer32,
+ acpmAvgVoltageVLowClass
+ DisplayString,
+ acpmAvgVoltageSysrepEnable
+ DisplayString,
+ acpmAvgVoltageSysrepThreshold
+ DisplayString,
+ acpmAvgVoltageSysrepLimit
+ Integer32
+}
+
+ACPMConfigAvgCurrent ::=
+ SEQUENCE {
+ acpmAvgCurrentIndex
+ Integer32,
+ acpmAvgCurrentEnable
+ DisplayString,
+ acpmAvgCurrentDeadband
+ DisplayString,
+ acpmAvgCurrentVHighValue
+ DisplayString,
+ acpmAvgCurrentVHighActions
+ DisplayString,
+ acpmAvgCurrentVHighTrapNum
+ Integer32,
+ acpmAvgCurrentVHighClass
+ DisplayString,
+ acpmAvgCurrentHighValue
+ DisplayString,
+ acpmAvgCurrentHighActions
+ DisplayString,
+ acpmAvgCurrentHighTrapNum
+ Integer32,
+ acpmAvgCurrentHighClass
+ DisplayString,
+ acpmAvgCurrentNormalActions
+ DisplayString,
+ acpmAvgCurrentNormalTrapNum
+ Integer32,
+ acpmAvgCurrentNormalClass
+ DisplayString,
+ acpmAvgCurrentLowValue
+ DisplayString,
+ acpmAvgCurrentLowActions
+ DisplayString,
+ acpmAvgCurrentLowTrapNum
+ Integer32,
+ acpmAvgCurrentLowClass
+ DisplayString,
+ acpmAvgCurrentVLowValue
+ DisplayString,
+ acpmAvgCurrentVLowActions
+ DisplayString,
+ acpmAvgCurrentVLowTrapNum
+ Integer32,
+ acpmAvgCurrentVLowClass
+ DisplayString,
+ acpmAvgCurrentSysrepEnable
+ DisplayString,
+ acpmAvgCurrentSysrepThreshold
+ DisplayString,
+ acpmAvgCurrentSysrepLimit
+ Integer32
+}
+
+ACPMConfigFreq ::=
+ SEQUENCE {
+ acpmFreqIndex
+ Integer32,
+ acpmFreqEnable
+ DisplayString,
+ acpmFreqDeadband
+ DisplayString,
+ acpmFreqVHighValue
+ DisplayString,
+ acpmFreqVHighActions
+ DisplayString,
+ acpmFreqVHighTrapNum
+ Integer32,
+ acpmFreqVHighClass
+ DisplayString,
+ acpmFreqHighValue
+ DisplayString,
+ acpmFreqHighActions
+ DisplayString,
+ acpmFreqHighTrapNum
+ Integer32,
+ acpmFreqHighClass
+ DisplayString,
+ acpmFreqNormalActions
+ DisplayString,
+ acpmFreqNormalTrapNum
+ Integer32,
+ acpmFreqNormalClass
+ DisplayString,
+ acpmFreqLowValue
+ DisplayString,
+ acpmFreqLowActions
+ DisplayString,
+ acpmFreqLowTrapNum
+ Integer32,
+ acpmFreqLowClass
+ DisplayString,
+ acpmFreqVLowValue
+ DisplayString,
+ acpmFreqVLowActions
+ DisplayString,
+ acpmFreqVLowTrapNum
+ Integer32,
+ acpmFreqVLowClass
+ DisplayString,
+ acpmFreqSysrepEnable
+ DisplayString,
+ acpmFreqSysrepThreshold
+ DisplayString,
+ acpmFreqSysrepLimit
+ Integer32
+}
+
+ACPMConfigTRP ::=
+ SEQUENCE {
+ acpmTRPIndex
+ Integer32,
+ acpmTRPEnable
+ DisplayString,
+ acpmTRPDeadband
+ DisplayString,
+ acpmTRPVHighValue
+ DisplayString,
+ acpmTRPVHighActions
+ DisplayString,
+ acpmTRPVHighTrapNum
+ Integer32,
+ acpmTRPVHighClass
+ DisplayString,
+ acpmTRPHighValue
+ DisplayString,
+ acpmTRPHighActions
+ DisplayString,
+ acpmTRPHighTrapNum
+ Integer32,
+ acpmTRPHighClass
+ DisplayString,
+ acpmTRPNormalActions
+ DisplayString,
+ acpmTRPNormalTrapNum
+ Integer32,
+ acpmTRPNormalClass
+ DisplayString,
+ acpmTRPLowValue
+ DisplayString,
+ acpmTRPLowActions
+ DisplayString,
+ acpmTRPLowTrapNum
+ Integer32,
+ acpmTRPLowClass
+ DisplayString,
+ acpmTRPVLowValue
+ DisplayString,
+ acpmTRPVLowActions
+ DisplayString,
+ acpmTRPVLowTrapNum
+ Integer32,
+ acpmTRPVLowClass
+ DisplayString,
+ acpmTRPSysrepEnable
+ DisplayString,
+ acpmTRPSysrepThreshold
+ DisplayString,
+ acpmTRPSysrepLimit
+ Integer32
+}
+
+ACPMConfigDisconnect ::=
+ SEQUENCE {
+ acpmDisconnectIndex
+ Integer32,
+ acpmDisconnectEnable
+ DisplayString,
+ acpmDisconnectActions
+ DisplayString,
+ acpmDisconnectTrapNum
+ Integer32,
+ acpmDisconnectClass
+ DisplayString,
+ acpmDisconnectNormalActions
+ DisplayString,
+ acpmDisconnectNormalTrapNum
+ Integer32,
+ acpmDisconnectNormalClass
+ DisplayString
+}
+
+ACPMConfigTotalPowerFactor ::=
+ SEQUENCE {
+ acpmTPFIndex
+ Integer32,
+ acpmTPFEnable
+ DisplayString,
+ acpmTPFDeadband
+ DisplayString,
+ acpmTPFNormalActions
+ DisplayString,
+ acpmTPFNormalTrapNum
+ Integer32,
+ acpmTPFNormalClass
+ DisplayString,
+ acpmTPFLowValue
+ DisplayString,
+ acpmTPFLowActions
+ DisplayString,
+ acpmTPFLowTrapNum
+ Integer32,
+ acpmTPFLowClass
+ DisplayString,
+ acpmTPFVLowValue
+ DisplayString,
+ acpmTPFVLowActions
+ DisplayString,
+ acpmTPFVLowTrapNum
+ Integer32,
+ acpmTPFVLowClass
+ DisplayString,
+ acpmTPFSysrepEnable
+ DisplayString,
+ acpmTPFSysrepThreshold
+ DisplayString,
+ acpmTPFSysrepLimit
+ Integer32
+}
+
+WebXMLProxyDeviceConfig ::=
+ SEQUENCE {
+ wxpDeviceIndex
+ Integer32,
+ wxpDeviceEnable
+ DisplayString,
+ wxpDeviceIPAddress
+ IpAddress,
+ wxpDevicePort
+ Integer32,
+ wxpDeviceRemoteFile
+ DisplayString,
+ wxpDeviceLocalFile
+ DisplayString,
+ wxpDeviceTimeout
+ Integer32,
+ wxpDeviceTimestamp
+ DisplayString
+}
+
+EthernetExpansionCardConfig ::=
+ SEQUENCE {
+ ethExpanCardIndex
+ Integer32,
+ ethExpanCardMAC
+ DisplayString
+}
+
+
+AccessControlDevice ::=
+ SEQUENCE {
+ acdIndex
+ Integer32,
+ acdEnable
+ DisplayString,
+ acdName
+ DisplayString,
+ acdReader
+ DisplayString,
+ acdWiegandES
+ Integer32,
+ acdWiegandPoint
+ Integer32,
+ acdRelayType
+ DisplayString,
+ acdRelayES
+ Integer32,
+ acdRelayPoint
+ Integer32,
+ acdOpenTime
+ Integer32,
+ acdUserGroup
+ Integer32
+}
+
+AccessControlUser ::=
+ SEQUENCE {
+ acuIndexUserGroup
+ Integer32,
+ acuIndexUser
+ Integer32,
+ acuEnable
+ DisplayString,
+ acuName
+ DisplayString,
+ acuSn
+ DisplayString,
+ acuSunBegin
+ DisplayString,
+ acuSunEnd
+ DisplayString,
+ acuMonBegin
+ DisplayString,
+ acuMonEnd
+ DisplayString,
+ acuTueBegin
+ DisplayString,
+ acuTueEnd
+ DisplayString,
+ acuWedBegin
+ DisplayString,
+ acuWedEnd
+ DisplayString,
+ acuThuBegin
+ DisplayString,
+ acuThuEnd
+ DisplayString,
+ acuFriBegin
+ DisplayString,
+ acuFriEnd
+ DisplayString,
+ acuSatBegin
+ DisplayString,
+ acuSatEnd
+ DisplayString
+}
+
+TelemetryPoint ::=
+ SEQUENCE {
+ telemetryPointIndex
+ Integer32,
+ telemetryPointName
+ DisplayString,
+ telemetryPointKey
+ DisplayString,
+ telemetryPointType
+ DisplayString,
+ telemetryPointClass
+ DisplayString,
+ telemetryPointDeadband
+ DisplayString,
+ telemetryPointShortcode
+ DisplayString
+}
+
+
+SiteSecIntrusion ::=
+ SEQUENCE {
+ siteSecEnable
+ DisplayString,
+ siteSecDisarmed
+ DisplayString,
+ siteSecName
+ DisplayString,
+ siteSecState
+ DisplayString,
+ siteSecSensorES
+ Integer32,
+ siteSecSensorPoint
+ Integer32,
+ siteSecIntrusionThreshold
+ Integer32,
+ siteSecReader
+ DisplayString,
+ siteSecReaderThreshold
+ Integer32,
+ siteSecButtonEnable
+ DisplayString,
+ siteSecButtonES
+ Integer32,
+ siteSecButtonPoint
+ Integer32,
+ siteSecButtonType
+ DisplayString,
+ siteSecButtonThresholdArm
+ Integer32,
+ siteSecButtonThresholdDisarm
+ Integer32,
+ siteSecSirenEnable
+ DisplayString,
+ siteSecSirenES
+ Integer32,
+ siteSecSirenPoint
+ Integer32,
+ siteSecRearmDelay
+ Integer32
+}
+
+SiteSecMotion ::=
+ SEQUENCE {
+
+ siteSecMotionES
+ Integer32,
+ siteSecMotionPoint
+ Integer32,
+ siteSecMotionEnable
+ DisplayString,
+ siteSecMotionName
+ DisplayString,
+ siteSecMotionThresholdRearm
+ Integer32
+}
+
+SiteSecDoorAjar ::=
+ SEQUENCE {
+ siteSecDoorAjarEnable
+ DisplayString,
+ siteSecDoorAjarName
+ DisplayString,
+ siteSecDoorAjarES
+ Integer32,
+ siteSecDoorAjarPoint
+ Integer32,
+ siteSecDoorAjarThresholdNormal
+ Integer32,
+ siteSecDoorAjarThresholdExtraTime
+ Integer32
+}
+
+
+
+
+--***************************************************************************************
+--TRAP DEFINITIONS
+--***************************************************************************************
+
+s550StockSensorUnresponsiveTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock unresponsive trap is issued when a sensor is unresponsive."
+ ::= { s550notifications 50 }
+
+s550notificationsStockContactClosureTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock contact closure trap is issued when a contact closure
+ event happens."
+ ::= { s550notifications 110 }
+
+s550notificationsStockTempTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock temperature trap is issued when a temperature event
+ happens."
+ ::= { s550notifications 120 }
+
+s550notificationsStockHumidityTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock humidity trap is issued when a humidity event
+ happens."
+ ::= { s550notifications 130 }
+
+s550notificationsStockAnalogTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when an analog sensor event
+ happens."
+ ::= { s550notifications 140 }
+
+s550notificationsStockOutputTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock output trap is issued when an output event
+ happens. That is, depending on the configuration,
+ when an output changes state for any reason, this
+ trap will be sent."
+ ::= { s550notifications 150 }
+
+s550StockPDCurrentTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ current event happens."
+ ::= { s550notifications 180 }
+
+s550StockPDVoltageTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ voltage event happens."
+ ::= { s550notifications 190 }
+
+s550StockPDFuseTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ fuse event happens."
+ ::= { s550notifications 210 }
+
+s550notificationsStockDbasePfullTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock database percent full trap is issued
+ when the database size surpasses the threshold."
+ ::= { s550notifications 501 }
+
+s550notificationsStockDataAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock data alarm trap is issued when a
+ data alarm happens."
+ ::= { s550notifications 503 }
+
+s550notificationsStockNoDataAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock no-data alarm trap is issued when
+ the unit has received no data for a configured
+ interval within a configured schedule."
+ ::= { s550notifications 505 }
+
+s550notificationsStockSchedTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock scheduled alarm trap is issued
+ when the current time reaches the scheduled
+ alarm time."
+ ::= { s550notifications 506 }
+
+s550notificationsStockImmediateTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock immediate alarm trap is issued
+ when the user enters the DOTRAP command."
+ ::= { s550notifications 507 }
+
+s550StockBattRunningTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, liBattPercentCharge, liBattRunning }
+ STATUS current
+ DESCRIPTION
+ "The stock trap issued when the battery power state change.
+ Gives the unit name, percentage charge of the battery and
+ if unit is running on battery backup (0 is False and 1 is True)"
+ ::= { s550notifications 508 }
+
+s550notificationsStockCTSTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock CTS trap is issued when an RS-232 CTS event
+ happens."
+ ::= { s550notifications 510 }
+
+s550notificationsCPEDownTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock CPE Down trap is issued when a CPE Down event
+ happens."
+ ::= { s550notifications 511 }
+
+s550notificationsFuelSensorDisconnectTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Disconnect trap is issued when a Fuel
+ Sensor Disconnect or Connect (Return to Normal) event happens."
+ ::= { s550notifications 515 }
+
+s550notificationsFuelSensorVolumeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume trap is issued when a Fuel
+ Sensor Volume event happens"
+ ::= { s550notifications 519 }
+
+s550notificationsACPowerMonitorAvgVoltageTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor average voltage trap is issued when an
+ AC power monitor average voltage event happens."
+ ::= { s550notifications 520 }
+
+s550notificationsACPowerMonitorAvgCurrentTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor average current trap is issued when an
+ AC power monitor average current event happens."
+ ::= { s550notifications 521 }
+
+s550notificationsACPowerMonitorFrequencyTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor frequency trap is issued when an
+ AC power monitor frequency event happens."
+ ::= { s550notifications 522 }
+
+s550notificationsACPowerMonitorTRPTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor TRP (total real power) trap is issued
+ when an AC power monitor TRP event happens."
+ ::= { s550notifications 523 }
+
+s550notificationsACPowerMonitorDisconnectTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor disconnect trap is issued
+ when an AC power monitor disconnect event happens."
+ ::= { s550notifications 524 }
+
+s550notificationsStockScriptTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock script trap is issued when a script triggers
+ an event via a_lib.PostEvent() called with no trap
+ number (or this trap number) specified."
+ ::= { s550notifications 526 }
+
+s550notificationsFuelSensorVolumeSuddenChangeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume Sudden Change trap is issued
+ when a Fuel Sensor Volume Sudden Change event happens"
+ ::= { s550notifications 527 }
+
+s550notificationsFuelSensorVolumeSlowChangeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume Slow Change trap is issued
+ when a Fuel Sensor Volume Slow Change event happens"
+ ::= { s550notifications 528 }
+
+s550notificationsCameraTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock camera trap is issued when a camera event happens."
+ ::= { s550notifications 539 }
+
+s550notificationsGeneratorNonStartTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Generator Non-start trap is issued
+ when the unit commands the generator to start as
+ part of the generator exercising feature, and the
+ generator fails to register as started after 30
+ seconds (as detected by CC generator running
+ detection)."
+ ::= { s550notifications 536 }
+
+s550notificationsACTotalPowerFactorTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor total power factor trap is issued
+ when an AC power monitor total power factor event happens."
+ ::= { s550notifications 540 }
+
+s550notificationsResetTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock reset trap is issued when a reset event happens."
+ ::= { s550notifications 543 }
+
+s550notificationHVACAsentriaControlTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock HVAC Asentria Control trap is issued when an issue with
+ temperature, humidity, fire detection and other HVAC related
+ event happens."
+ ::= { s550notifications 545 }
+
+s550notificationAccessControlTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock access control trap is issued when an access control
+ device management event happens."
+ ::= { s550notifications 547 }
+
+s550notificationHVACAirsysControlTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock HVAC Airsys Control trap is issued when an issue
+ related to alarm conditions for the Airsys HVAC system
+ event happens."
+ ::= { s550notifications 548 }
+
+s550notificationsUserTrap1000 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1000."
+ ::= { s550notifications 1000 }
+
+s550notificationsUserTrap1001 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1001."
+ ::= { s550notifications 1001 }
+
+s550notificationsUserTrap1002 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1002."
+ ::= { s550notifications 1002 }
+
+s550notificationsUserTrap1003 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1003."
+ ::= { s550notifications 1003 }
+
+s550notificationsUserTrap1004 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1004."
+ ::= { s550notifications 1004 }
+
+s550notificationsUserTrap1005 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1005."
+ ::= { s550notifications 1005 }
+
+s550notificationsUserTrap1006 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1006."
+ ::= { s550notifications 1006 }
+
+s550notificationsUserTrap1007 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1007."
+ ::= { s550notifications 1007 }
+
+s550notificationsUserTrap1008 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1008."
+ ::= { s550notifications 1008 }
+
+s550notificationsUserTrap1009 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1009."
+ ::= { s550notifications 1009 }
+
+s550notificationsUserTrap1010 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1010."
+ ::= { s550notifications 1010 }
+
+s550notificationsUserTrap1011 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1011."
+ ::= { s550notifications 1011 }
+
+s550notificationsUserTrap1012 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1012."
+ ::= { s550notifications 1012 }
+
+s550notificationsUserTrap1013 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1013."
+ ::= { s550notifications 1013 }
+
+s550notificationsUserTrap1014 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1014."
+ ::= { s550notifications 1014 }
+
+s550notificationsUserTrap1015 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1015."
+ ::= { s550notifications 1015 }
+
+s550notificationsUserTrap1016 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1016."
+ ::= { s550notifications 1016 }
+
+s550notificationsUserTrap1017 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1017."
+ ::= { s550notifications 1017 }
+
+s550notificationsUserTrap1018 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1018."
+ ::= { s550notifications 1018 }
+
+s550notificationsUserTrap1019 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1019."
+ ::= { s550notifications 1019 }
+
+s550notificationsUserTrap1020 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1020."
+ ::= { s550notifications 1020 }
+
+s550notificationsUserTrap1021 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1021."
+ ::= { s550notifications 1021 }
+
+s550notificationsUserTrap1022 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1022."
+ ::= { s550notifications 1022 }
+
+s550notificationsUserTrap1023 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1023."
+ ::= { s550notifications 1023 }
+
+s550notificationsUserTrap1024 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1024."
+ ::= { s550notifications 1024 }
+
+s550notificationsUserTrap1025 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1025."
+ ::= { s550notifications 1025 }
+
+s550notificationsUserTrap1026 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1026."
+ ::= { s550notifications 1026 }
+
+s550notificationsUserTrap1027 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1027."
+ ::= { s550notifications 1027 }
+
+s550notificationsUserTrap1028 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1028."
+ ::= { s550notifications 1028 }
+
+s550notificationsUserTrap1029 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1029."
+ ::= { s550notifications 1029 }
+
+s550notificationsUserTrap1030 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1030."
+ ::= { s550notifications 1030 }
+
+s550notificationsUserTrap1031 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1031."
+ ::= { s550notifications 1031 }
+
+s550notificationsUserTrap1032 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1032."
+ ::= { s550notifications 1032 }
+
+s550notificationsUserTrap1033 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1033."
+ ::= { s550notifications 1033 }
+
+s550notificationsUserTrap1034 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1034."
+ ::= { s550notifications 1034 }
+
+s550notificationsUserTrap1035 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1035."
+ ::= { s550notifications 1035 }
+
+s550notificationsUserTrap1036 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1036."
+ ::= { s550notifications 1036 }
+
+s550notificationsUserTrap1037 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1037."
+ ::= { s550notifications 1037 }
+
+s550notificationsUserTrap1038 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1038."
+ ::= { s550notifications 1038 }
+
+s550notificationsUserTrap1039 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1039."
+ ::= { s550notifications 1039 }
+
+s550notificationsUserTrap1040 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1040."
+ ::= { s550notifications 1040 }
+
+s550notificationsUserTrap1041 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1041."
+ ::= { s550notifications 1041 }
+
+s550notificationsUserTrap1042 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1042."
+ ::= { s550notifications 1042 }
+
+s550notificationsUserTrap1043 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1043."
+ ::= { s550notifications 1043 }
+
+s550notificationsUserTrap1044 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1044."
+ ::= { s550notifications 1044 }
+
+s550notificationsUserTrap1045 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1045."
+ ::= { s550notifications 1045 }
+
+s550notificationsUserTrap1046 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1046."
+ ::= { s550notifications 1046 }
+
+s550notificationsUserTrap1047 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1047."
+ ::= { s550notifications 1047 }
+
+s550notificationsUserTrap1048 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1048."
+ ::= { s550notifications 1048 }
+
+s550notificationsUserTrap1049 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1049."
+ ::= { s550notifications 1049 }
+
+s550notificationsUserTrap1050 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1050."
+ ::= { s550notifications 1050 }
+
+s550notificationsUserTrap1051 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1051."
+ ::= { s550notifications 1051 }
+
+s550notificationsUserTrap1052 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1052."
+ ::= { s550notifications 1052 }
+
+s550notificationsUserTrap1053 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1053."
+ ::= { s550notifications 1053 }
+
+s550notificationsUserTrap1054 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1054."
+ ::= { s550notifications 1054 }
+
+s550notificationsUserTrap1055 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1055."
+ ::= { s550notifications 1055 }
+
+s550notificationsUserTrap1056 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1056."
+ ::= { s550notifications 1056 }
+
+s550notificationsUserTrap1057 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1057."
+ ::= { s550notifications 1057 }
+
+s550notificationsUserTrap1058 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1058."
+ ::= { s550notifications 1058 }
+
+s550notificationsUserTrap1059 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1059."
+ ::= { s550notifications 1059 }
+
+s550notificationsUserTrap1060 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1060."
+ ::= { s550notifications 1060 }
+
+s550notificationsUserTrap1061 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1061."
+ ::= { s550notifications 1061 }
+
+s550notificationsUserTrap1062 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1062."
+ ::= { s550notifications 1062 }
+
+s550notificationsUserTrap1063 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1063."
+ ::= { s550notifications 1063 }
+
+s550notificationsUserTrap1064 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1064."
+ ::= { s550notifications 1064 }
+
+s550notificationsUserTrap1065 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1065."
+ ::= { s550notifications 1065 }
+
+s550notificationsUserTrap1066 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1066."
+ ::= { s550notifications 1066 }
+
+s550notificationsUserTrap1067 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1067."
+ ::= { s550notifications 1067 }
+
+s550notificationsUserTrap1068 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1068."
+ ::= { s550notifications 1068 }
+
+s550notificationsUserTrap1069 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1069."
+ ::= { s550notifications 1069 }
+
+s550notificationsUserTrap1070 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1070."
+ ::= { s550notifications 1070 }
+
+s550notificationsUserTrap1071 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1071."
+ ::= { s550notifications 1071 }
+
+s550notificationsUserTrap1072 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1072."
+ ::= { s550notifications 1072 }
+
+s550notificationsUserTrap1073 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1073."
+ ::= { s550notifications 1073 }
+
+s550notificationsUserTrap1074 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1074."
+ ::= { s550notifications 1074 }
+
+s550notificationsUserTrap1075 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1075."
+ ::= { s550notifications 1075 }
+
+s550notificationsUserTrap1076 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1076."
+ ::= { s550notifications 1076 }
+
+s550notificationsUserTrap1077 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1077."
+ ::= { s550notifications 1077 }
+
+s550notificationsUserTrap1078 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1078."
+ ::= { s550notifications 1078 }
+
+s550notificationsUserTrap1079 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1079."
+ ::= { s550notifications 1079 }
+
+s550notificationsUserTrap1080 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1080."
+ ::= { s550notifications 1080 }
+
+s550notificationsUserTrap1081 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1081."
+ ::= { s550notifications 1081 }
+
+s550notificationsUserTrap1082 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1082."
+ ::= { s550notifications 1082 }
+
+s550notificationsUserTrap1083 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1083."
+ ::= { s550notifications 1083 }
+
+s550notificationsUserTrap1084 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1084."
+ ::= { s550notifications 1084 }
+
+s550notificationsUserTrap1085 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1085."
+ ::= { s550notifications 1085 }
+
+s550notificationsUserTrap1086 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1086."
+ ::= { s550notifications 1086 }
+
+s550notificationsUserTrap1087 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1087."
+ ::= { s550notifications 1087 }
+
+s550notificationsUserTrap1088 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1088."
+ ::= { s550notifications 1088 }
+
+s550notificationsUserTrap1089 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1089."
+ ::= { s550notifications 1089 }
+
+s550notificationsUserTrap1090 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1090."
+ ::= { s550notifications 1090 }
+
+s550notificationsUserTrap1091 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1091."
+ ::= { s550notifications 1091 }
+
+s550notificationsUserTrap1092 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1092."
+ ::= { s550notifications 1092 }
+
+s550notificationsUserTrap1093 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1093."
+ ::= { s550notifications 1093 }
+
+s550notificationsUserTrap1094 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1094."
+ ::= { s550notifications 1094 }
+
+s550notificationsUserTrap1095 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1095."
+ ::= { s550notifications 1095 }
+
+s550notificationsUserTrap1096 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1096."
+ ::= { s550notifications 1096 }
+
+s550notificationsUserTrap1097 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1097."
+ ::= { s550notifications 1097 }
+
+s550notificationsUserTrap1098 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1098."
+ ::= { s550notifications 1098 }
+
+s550notificationsUserTrap1099 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1099."
+ ::= { s550notifications 1099 }
+
+s550notificationsUserTrap1100 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1100."
+ ::= { s550notifications 1100 }
+
+s550notificationsUserTrap1101 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1101."
+ ::= { s550notifications 1101 }
+
+s550notificationsUserTrap1102 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1102."
+ ::= { s550notifications 1102 }
+
+s550notificationsUserTrap1103 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1103."
+ ::= { s550notifications 1103 }
+
+s550notificationsUserTrap1104 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1104."
+ ::= { s550notifications 1104 }
+
+s550notificationsUserTrap1105 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1105."
+ ::= { s550notifications 1105 }
+
+s550notificationsUserTrap1106 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1106."
+ ::= { s550notifications 1106 }
+
+s550notificationsUserTrap1107 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1107."
+ ::= { s550notifications 1107 }
+
+s550notificationsUserTrap1108 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1108."
+ ::= { s550notifications 1108 }
+
+s550notificationsUserTrap1109 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1109."
+ ::= { s550notifications 1109 }
+
+s550notificationsUserTrap1110 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1110."
+ ::= { s550notifications 1110 }
+
+s550notificationsUserTrap1111 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1111."
+ ::= { s550notifications 1111 }
+
+s550notificationsUserTrap1112 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1112."
+ ::= { s550notifications 1112 }
+
+s550notificationsUserTrap1113 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1113."
+ ::= { s550notifications 1113 }
+
+s550notificationsUserTrap1114 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1114."
+ ::= { s550notifications 1114 }
+
+s550notificationsUserTrap1115 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1115."
+ ::= { s550notifications 1115 }
+
+s550notificationsUserTrap1116 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1116."
+ ::= { s550notifications 1116 }
+
+s550notificationsUserTrap1117 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1117."
+ ::= { s550notifications 1117 }
+
+s550notificationsUserTrap1118 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1118."
+ ::= { s550notifications 1118 }
+
+s550notificationsUserTrap1119 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1119."
+ ::= { s550notifications 1119 }
+
+s550notificationsUserTrap1120 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1120."
+ ::= { s550notifications 1120 }
+
+s550notificationsUserTrap1121 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1121."
+ ::= { s550notifications 1121 }
+
+s550notificationsUserTrap1122 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1122."
+ ::= { s550notifications 1122 }
+
+s550notificationsUserTrap1123 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1123."
+ ::= { s550notifications 1123 }
+
+s550notificationsUserTrap1124 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1124."
+ ::= { s550notifications 1124 }
+
+s550notificationsUserTrap1125 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1125."
+ ::= { s550notifications 1125 }
+
+s550notificationsUserTrap1126 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1126."
+ ::= { s550notifications 1126 }
+
+s550notificationsUserTrap1127 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1127."
+ ::= { s550notifications 1127 }
+
+s550notificationsUserTrap1128 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1128."
+ ::= { s550notifications 1128 }
+
+s550notificationsUserTrap1129 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1129."
+ ::= { s550notifications 1129 }
+
+s550notificationsUserTrap1130 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1130."
+ ::= { s550notifications 1130 }
+
+s550notificationsUserTrap1131 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1131."
+ ::= { s550notifications 1131 }
+
+s550notificationsUserTrap1132 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1132."
+ ::= { s550notifications 1132 }
+
+s550notificationsUserTrap1133 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1133."
+ ::= { s550notifications 1133 }
+
+s550notificationsUserTrap1134 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1134."
+ ::= { s550notifications 1134 }
+
+s550notificationsUserTrap1135 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1135."
+ ::= { s550notifications 1135 }
+
+s550notificationsUserTrap1136 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1136."
+ ::= { s550notifications 1136 }
+
+s550notificationsUserTrap1137 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1137."
+ ::= { s550notifications 1137 }
+
+s550notificationsUserTrap1138 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1138."
+ ::= { s550notifications 1138 }
+
+s550notificationsUserTrap1139 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1139."
+ ::= { s550notifications 1139 }
+
+s550notificationsUserTrap1140 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1140."
+ ::= { s550notifications 1140 }
+
+s550notificationsUserTrap1141 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1141."
+ ::= { s550notifications 1141 }
+
+s550notificationsUserTrap1142 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1142."
+ ::= { s550notifications 1142 }
+
+s550notificationsUserTrap1143 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1143."
+ ::= { s550notifications 1143 }
+
+s550notificationsUserTrap1144 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1144."
+ ::= { s550notifications 1144 }
+
+s550notificationsUserTrap1145 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1145."
+ ::= { s550notifications 1145 }
+
+s550notificationsUserTrap1146 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1146."
+ ::= { s550notifications 1146 }
+
+s550notificationsUserTrap1147 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1147."
+ ::= { s550notifications 1147 }
+
+s550notificationsUserTrap1148 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1148."
+ ::= { s550notifications 1148 }
+
+s550notificationsUserTrap1149 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1149."
+ ::= { s550notifications 1149 }
+
+s550notificationsUserTrap1150 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1150."
+ ::= { s550notifications 1150 }
+
+s550notificationsUserTrap1151 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1151."
+ ::= { s550notifications 1151 }
+
+s550notificationsUserTrap1152 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1152."
+ ::= { s550notifications 1152 }
+
+s550notificationsUserTrap1153 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1153."
+ ::= { s550notifications 1153 }
+
+s550notificationsUserTrap1154 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1154."
+ ::= { s550notifications 1154 }
+
+s550notificationsUserTrap1155 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1155."
+ ::= { s550notifications 1155 }
+
+s550notificationsUserTrap1156 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1156."
+ ::= { s550notifications 1156 }
+
+s550notificationsUserTrap1157 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1157."
+ ::= { s550notifications 1157 }
+
+s550notificationsUserTrap1158 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1158."
+ ::= { s550notifications 1158 }
+
+s550notificationsUserTrap1159 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1159."
+ ::= { s550notifications 1159 }
+
+s550notificationsUserTrap1160 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1160."
+ ::= { s550notifications 1160 }
+
+s550notificationsUserTrap1161 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1161."
+ ::= { s550notifications 1161 }
+
+s550notificationsUserTrap1162 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1162."
+ ::= { s550notifications 1162 }
+
+s550notificationsUserTrap1163 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1163."
+ ::= { s550notifications 1163 }
+
+s550notificationsUserTrap1164 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1164."
+ ::= { s550notifications 1164 }
+
+s550notificationsUserTrap1165 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1165."
+ ::= { s550notifications 1165 }
+
+s550notificationsUserTrap1166 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1166."
+ ::= { s550notifications 1166 }
+
+s550notificationsUserTrap1167 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1167."
+ ::= { s550notifications 1167 }
+
+s550notificationsUserTrap1168 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1168."
+ ::= { s550notifications 1168 }
+
+s550notificationsUserTrap1169 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1169."
+ ::= { s550notifications 1169 }
+
+s550notificationsUserTrap1170 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1170."
+ ::= { s550notifications 1170 }
+
+s550notificationsUserTrap1171 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1171."
+ ::= { s550notifications 1171 }
+
+s550notificationsUserTrap1172 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1172."
+ ::= { s550notifications 1172 }
+
+s550notificationsUserTrap1173 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1173."
+ ::= { s550notifications 1173 }
+
+s550notificationsUserTrap1174 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1174."
+ ::= { s550notifications 1174 }
+
+s550notificationsUserTrap1175 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1175."
+ ::= { s550notifications 1175 }
+
+s550notificationsUserTrap1176 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1176."
+ ::= { s550notifications 1176 }
+
+s550notificationsUserTrap1177 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1177."
+ ::= { s550notifications 1177 }
+
+s550notificationsUserTrap1178 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1178."
+ ::= { s550notifications 1178 }
+
+s550notificationsUserTrap1179 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1179."
+ ::= { s550notifications 1179 }
+
+s550notificationsUserTrap1180 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1180."
+ ::= { s550notifications 1180 }
+
+s550notificationsUserTrap1181 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1181."
+ ::= { s550notifications 1181 }
+
+s550notificationsUserTrap1182 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1182."
+ ::= { s550notifications 1182 }
+
+s550notificationsUserTrap1183 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1183."
+ ::= { s550notifications 1183 }
+
+s550notificationsUserTrap1184 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1184."
+ ::= { s550notifications 1184 }
+
+s550notificationsUserTrap1185 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1185."
+ ::= { s550notifications 1185 }
+
+s550notificationsUserTrap1186 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1186."
+ ::= { s550notifications 1186 }
+
+s550notificationsUserTrap1187 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1187."
+ ::= { s550notifications 1187 }
+
+s550notificationsUserTrap1188 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1188."
+ ::= { s550notifications 1188 }
+
+s550notificationsUserTrap1189 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1189."
+ ::= { s550notifications 1189 }
+
+s550notificationsUserTrap1190 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1190."
+ ::= { s550notifications 1190 }
+
+s550notificationsUserTrap1191 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1191."
+ ::= { s550notifications 1191 }
+
+s550notificationsUserTrap1192 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1192."
+ ::= { s550notifications 1192 }
+
+s550notificationsUserTrap1193 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1193."
+ ::= { s550notifications 1193 }
+
+s550notificationsUserTrap1194 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1194."
+ ::= { s550notifications 1194 }
+
+s550notificationsUserTrap1195 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1195."
+ ::= { s550notifications 1195 }
+
+s550notificationsUserTrap1196 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1196."
+ ::= { s550notifications 1196 }
+
+s550notificationsUserTrap1197 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1197."
+ ::= { s550notifications 1197 }
+
+s550notificationsUserTrap1198 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1198."
+ ::= { s550notifications 1198 }
+
+s550notificationsUserTrap1199 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1199."
+ ::= { s550notifications 1199 }
+
+END
diff --git a/MIBS/asentria/SITEBOSS-571-STD-MIB b/MIBS/asentria/SITEBOSS-571-STD-MIB
new file mode 100644
index 0000000..5f091cf
--- /dev/null
+++ b/MIBS/asentria/SITEBOSS-571-STD-MIB
@@ -0,0 +1,18303 @@
+-- SiteBoss 571 MIB
+
+-- v 1.44 December 30 2014
+
+-- Copyright (c) 2014 by Asentria Corporation. All rights reserved.
+
+
+SITEBOSS-571-STD-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ DisplayString
+ FROM SNMPv2-TC
+ IpAddress, TimeTicks, Integer32,
+ MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
+ FROM SNMPv2-SMI
+ asentria
+ FROM ASENTRIA-ROOT-MIB;
+
+--***************************************************************************************
+--MODULE IDENTITY
+--***************************************************************************************
+
+ s571 MODULE-IDENTITY
+ LAST-UPDATED "201412300144Z"
+ ORGANIZATION "Asentria Corporation"
+ CONTACT-INFO
+ "Phone: 206-344-8800
+ Fax: 206-344-2116
+ Email: support@asentria.com"
+ DESCRIPTION
+ "MIB module for managing Asentria SiteBoss 571"
+
+ REVISION "201412300144Z"
+ DESCRIPTION
+ "-v1.44
+ -Removed wirelessPIN and scSecret objects (OMX-1064).
+ -Applicable since unit version 2.10.610."
+
+ REVISION "201412110143Z"
+ DESCRIPTION
+ "-v1.43
+ -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
+ -Added missing ipv6DefaultRouter object (OMX-1175).
+ -Applicable since unit version 2.10.580."
+
+ REVISION "201410160142Z"
+ DESCRIPTION
+ "-v1.42
+ -Added espcAIDisplayFormat object (OMX-1112).
+ -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201410030141Z"
+ DESCRIPTION
+ "-v1.41
+ -Changed analog input objects from Integer32 to DisplayString.
+ -Applicable since unit version 2.10.460."
+
+ REVISION "201408140140Z"
+ DESCRIPTION
+ "-v1.40
+ -Fixed description for wirelessConnIP objects (OMX-1061).
+ -Applicable since unit version 2.10.390."
+
+ REVISION "201407030139Z"
+ DESCRIPTION
+ "-v1.39
+ -Fixed wirelessIdleTimeout (OMX-1037).
+ -Fixed CPE status objects (OMX-1036).
+ -Applicable since unit version 2.10.390."
+
+ REVISION "201406240138Z"
+ DESCRIPTION
+ "-v1.38
+ -Fixed CPE status objects.
+ -Applicable since unit version 2.10.340."
+
+ REVISION "201405290137Z"
+ DESCRIPTION
+ "-v1.37
+ -Added various missing objects (OMX-751).
+ -Added CPE objects (OMX-162).
+ -Applicable since unit version 2.10.320."
+
+ REVISION "201404110136Z"
+ DESCRIPTION
+ "-v1.36
+ -Clarified relay and power output function and documentation (OMX-926).
+ -Applicable since unit version 2.10.300."
+
+ REVISION "201401170135Z"
+ DESCRIPTION
+ "-v1.35
+ -Added IPv6 objects (OMX-705).
+ -Added power distribution objects (powerDistributionStatus branch) (OMX-708).
+ -Fixed ipRestrictionMask wrong type (OMX-743).
+ -Added ftpPushPermissions (OMX-737).
+ -Added snmpProxy objects (OMX-747).
+ -Applicable since unit version 2.10.150."
+
+ REVISION "201312040134Z"
+ DESCRIPTION
+ "-v1.34
+ -Added fsGenEnable (OMX-661).
+ -Applicable since unit version 2.10.110."
+
+ REVISION "201309040133Z"
+ DESCRIPTION
+ "-v1.33
+ -Added pdSystemCurrent and pdSystemPower objects (OMX-527).
+ -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528).
+ -Applicable since unit version 2.09.626."
+
+ REVISION "201308010132Z"
+ DESCRIPTION
+ "-v1.32
+ -Added missing trapEventTypeNumber available values in description (OMX-437).
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201307170131Z"
+ DESCRIPTION
+ "-v1.31
+ -Corrected snmpPBufferAllPeriod object.
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201307020130Z"
+ DESCRIPTION
+ "-v1.30
+ -Added snmpPoll objects (OMX-394).
+ -Applicable since unit version 2.09.560."
+
+ REVISION "201306280129Z"
+ DESCRIPTION
+ "-v1.29
+ -Removed Ethernet Expansion card objects.
+ -Applicable since unit version 2.09.540."
+
+ REVISION "201306130128Z"
+ DESCRIPTION
+ "-v1.28
+ -Added sysFileTransfer and sysUpdate objects. (OMX-42)
+ -Applicable since unit version 2.09.520."
+
+ REVISION "201306120127Z"
+ DESCRIPTION
+ "-v1.27
+ -Renamed EX10 to Ethernet Expansion (OMX-364)
+ -Applicable since unit version 2.09.510."
+
+ REVISION "201305280126Z"
+ DESCRIPTION
+ "-v1.26
+ -Fixed incorrect SYNTAX for sysCharMask (OMX-328).
+ -Applicable since unit version 2.09.380."
+
+ REVISION "201305100125Z"
+ DESCRIPTION
+ "-v1.25
+ -Fixed incorrect SYNTAX statements for various objects (OMX-314).
+ -Applicable since unit version 2.09.380."
+
+ REVISION "201303150124Z"
+ DESCRIPTION
+ "-v1.24
+ -Renamed sysLocation branch to sysLoc (OMX-198).
+ -Applicable since unit version 2.09.240."
+
+ REVISION "201302060123Z"
+ DESCRIPTION
+ "-v1.23
+ -Added ex10 branch.
+ -Renamed telnet* objects.
+ -Applicable since unit version 2.09.240."
+
+ REVISION "201301140122Z"
+ DESCRIPTION
+ "-v1.22
+ -Added evReset branch and associated notification (OMX-83).
+ -Applicable since unit version 2.09.220."
+
+ REVISION "201211260121Z"
+ DESCRIPTION
+ "-v1.21
+ -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
+
+ REVISION "201208220120Z"
+ DESCRIPTION
+ "-v1.20
+ -Added additional AC power monitor items."
+
+ REVISION "201207090119Z"
+ DESCRIPTION
+ "-v1.19
+ -Removed wirelessBand object.
+ -Removed secSSH objects."
+
+ REVISION "201206120118Z"
+ DESCRIPTION
+ "-v1.18
+ -Removed user credentials objects.
+ -Added combined power distributor status objects."
+
+ REVISION "201204090117Z"
+ DESCRIPTION
+ "-v1.17
+ -Added eth2WanRoutingEnable object."
+
+ REVISION "201204050116Z"
+ DESCRIPTION
+ "-v1.16
+ -Added combined eventsensor status objects."
+
+ REVISION "201203060115Z"
+ DESCRIPTION
+ "-v1.15
+ -Added objects and trap definitions for fuel sensor and AC power monitor."
+
+ REVISION "201112050900Z"
+ DESCRIPTION
+ "-v1.14
+ -Added s571StockScriptTrap notification definition."
+
+ REVISION "201110240900Z"
+ DESCRIPTION
+ "-v1.13
+ -Added s571StockLoadSheddingTrap notification definition."
+
+ REVISION "201108080900Z"
+ DESCRIPTION
+ "-v1.12
+ -Added s571StockOutputTrap notification definition."
+
+ REVISION "201108010900Z"
+ DESCRIPTION
+ "-v1.11
+ -Added evMgmtReprocess object."
+
+ REVISION "201107200900Z"
+ DESCRIPTION
+ "-v1.10
+ -Added aisgStatus branch."
+
+ REVISION "201107080900Z"
+ DESCRIPTION
+ "-v1.09
+ -Added wirelessModemStatus branch."
+
+ REVISION "201101050900Z"
+ DESCRIPTION
+ "-v1.08
+ -Added espcCCNormalThreshold object."
+
+ REVISION "201012010900Z"
+ DESCRIPTION
+ "-v1.07
+ -Added support for PowerBoss external power distributors. This is in the
+ pdNextGen object branch which also supports the internal power distributor
+ of the SiteBoss 571. The old SNMP support for the internal power
+ distributor is kept in the older sub-branches of the powerDistributionStatus
+ branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object
+ branch is that there are 31 items for power monitoring and alarming, and
+ these items are organized in a double-indexed SNMP table object: the first
+ index is for the power distributor (and has the same numbering scheme as an
+ EventSensor -- like esIndexES, but is called pdnIndexPD), and the second
+ index is the power output to which the item applies (or just '1' if the item
+ is not specific to a particular power output). E.g., to read the main
+ current of the internal power distributor, you can use the old object
+ (pdMainCurrentValue.0) or you can use the new object
+ (pdnMainCurrentValue.200.1). To read the fuse event state of power output
+ number 8 on the power distributor (PowerBoss) at index 2, read
+ pdnOutputFuseInEventState.2.8."
+
+ REVISION "201011030900Z"
+ DESCRIPTION
+ "-v1.06
+ -Changed deadband, threshold, and current values for temperature
+ sensors from integer to floating-point type. This means the
+ SNMP object type for the temperature settings (deadbands and
+ thresholds) changed from Integer32 to DisplayString.
+ -Fixed bug where SNMP integer range defined in the MIB for
+ trapIncludedValue was 16-bit instead of 32-bit."
+
+ REVISION "201008240900Z"
+ DESCRIPTION
+ "-v1.05
+ -Fixed bug where some stock traps had too few varbinds declared.
+ -Removed useless trap definitions."
+
+ REVISION "201003170900Z"
+ DESCRIPTION
+ "-v1.04
+ -Removed useless object consoleInlineHsk.
+ -Added asset management object branch.
+ -Added altitude location object.
+ -Removed all obsolete switch references, made everything consistent
+ on outputs (relay outputs or power outputs).
+ -Added threshold objects for power distribution sensors.
+ -Added pdOutputCurrentValue object.
+ -Fixed description for pdOutputCurrentInEventState."
+
+ REVISION "201001190900Z"
+ DESCRIPTION
+ "-v1.03
+ -Increased range for esPointValueInt"
+
+ REVISION "200910080900Z"
+ DESCRIPTION
+ "-v1.02
+ -Incremental pre-release changes"
+
+ REVISION "200910050900Z"
+ DESCRIPTION
+ "-v1.01
+ -Incremental pre-release changes"
+
+ REVISION "200909170900Z"
+ DESCRIPTION
+ "-v1.00
+ -Initial version."
+
+ ::= { asentria 14 }
+ --1.3.6.1.4.1.3052.14
+
+
+
+--***************************************************************************************
+--Concise MIB View: Top Level Branches
+--***************************************************************************************
+
+-- status .1
+-- eventSensorStatus .1.1
+-- esPointTable .1.1.1
+-- dataEventStatus .1.2
+-- deStatusTable .1.2.1
+-- modemStatus .1.3
+-- modemCLIDLogTable .1.4
+-- powerDistributionStatus .1.5
+-- fuelSensorStatus .1.6
+-- fsStatusTable .1.6.1
+-- wirelessModemStatus .1.7
+-- acPowerMonitorStatus .1.8
+-- acpmStatusTable .1.8.1
+-- aisgStatus .1.9
+-- config .2
+-- eventSensorBasics .2.1
+-- esNumberEventSensors .2.1.1
+-- esTable .2.1.2
+-- esNewSensors .2.1.3
+-- eventSensorPointConfig .2.2
+-- esPointConfigTempTable .2.2.1
+-- esPointConfigCCTable .2.2.2
+-- esPointConfigHumidTable .2.2.3
+-- esPointConfigAITable .2.2.5
+-- esPointConfigOutputTable .2.2.6
+-- serialPorts .2.3
+-- numberPorts .2.3.1
+-- portConfigTable .2.3.2
+-- network .2.4
+-- interface .2.4.1
+-- defaultRouter .2.4.2
+-- dnsTable .2.4.3
+-- hostname .2.4.4
+-- hostTable .2.4.5
+-- ncpDuplex .2.4.6
+-- ncpTimeout .2.4.7
+-- snmp .2.4.8
+-- ftpPush .2.4.9
+-- ppp .2.4.10
+-- routing .2.4.11
+-- netSecurity .2.4.12
+-- rts .2.4.13
+-- trap .2.4.14
+-- routeTest .2.4.15
+-- gprs .2.4.16
+-- email .2.4.17
+-- netAdvanced .2.4.18
+-- web .2.4.19
+-- ipv6 .2.4.21
+-- cpe .2.4.22
+-- modem .2.5
+-- time .2.8
+-- clock .2.8.1
+-- console .2.10
+-- unitSecurity .2.11
+-- secCore .2.11.1
+-- secUserTable .2.11.2
+-- secFactory .2.11.3
+-- secVPN .2.11.5
+-- event .2.12
+-- evCore .2.12.1
+-- evData .2.12.2
+-- evNoData1 .2.12.3
+-- evNoData2 .2.12.4
+-- evSched1 .2.12.5
+-- evSched2 .2.12.6
+-- evShskLowTable .2.12.7
+-- evShskHighTable .2.12.8
+-- evNoSensor .2.12.9
+-- fuelSensor .2.12.11
+-- fuelSensorGeneralTable .2.12.11.1
+-- fuelSensorTankTable .2.12.11.2
+-- fuelSensorCustomTankTable .2.12.11.3
+-- fuelSensorVolumeTable .2.12.11.4
+-- fuelSensorDisconnectTable .2.12.11.5
+-- acPowerMonitor .2.12.12
+-- evReset .2.12.16
+-- action .2.14
+-- actionCallNumberTable .2.14.1
+-- actionPagerTable .2.14.2
+-- actionSched .2.14.3
+-- actionAsentria .2.14.4
+-- actionHostTable .2.14.6
+-- actionEmailTable .2.14.7
+-- actionParseError .2.14.8
+-- sys .2.16
+-- sysTime .2.16.1
+-- sysPT .2.16.2
+-- sysMTU .2.16.3
+-- sysAnswerString .2.16.4
+-- sysEventFileID .2.16.6
+-- sysEscapeCharacter .2.16.7
+-- sysTimeStamp .2.16.8
+-- sysLog .2.16.9
+-- sysCRDB .2.16.10
+-- sysCharMask .2.16.11
+-- sysPrompt .2.16.12
+-- sysBootStatus .2.16.13
+-- sysLoc .2.16.14
+-- sysAssetMgmt .2.16.15
+-- sysFileTransfer .2.16.17
+-- sysUpdate .2.16.18
+-- auditLog .2.17
+-- scripting .2.18
+-- scrGlobalEnable .2.18.1
+-- scrDTRCtrlPortEnableTable .2.18.2
+-- scrTable .2.18.3
+-- scrVolatileStringTable .2.18.4
+-- scrVolatileIntTable .2.18.5
+-- scrNonVolatileStringTable .2.18.6
+-- scrNonVolatileIntTable .2.18.7
+-- productIds .3
+-- siteName 3.1
+-- thisProduct .3.2
+-- stockTrapString .3.3
+-- trapEventTypeNumber .3.4
+-- trapEventTypeName .3.5
+-- trapIncludedValue .3.6
+-- trapIncludedString .3.7
+-- trapTypeString .3.8
+-- trapEventClassNumber .3.9
+-- trapEventClassName .3.10
+-- keyInterface .4.0
+
+--***************************************************************************************
+--Complete MIB View: All Objects
+--***************************************************************************************
+
+-- status .1
+-- eventSensorStatus .1.1
+-- esPointTable .1.1.1
+-- esPointEntry .1.1.1.1
+-- esIndexES .1.1.1.1.1
+-- esIndexPC .1.1.1.1.2
+-- esIndexPoint .1.1.1.1.3
+-- esPointName .1.1.1.1.4
+-- esPointInEventState .1.1.1.1.5
+-- esPointValueInt .1.1.1.1.6
+-- esPointValueStr .1.1.1.1.7
+-- esPointTimeLastChange .1.1.1.1.8
+-- esPointTimetickLastChange .1.1.1.1.9
+-- dataEventStatus .1.2
+-- deStatusTable .1.2.1
+-- deStatusEntry .1.2.1.1
+-- deStatusIndex .1.2.1.1.1
+-- deStatusName .1.2.1.1.2
+-- deStatusCounter .1.2.1.1.3
+-- deStatusThreshold .1.2.1.1.4
+-- modemStatus .1.3
+-- modemCLIDLogTable .1.4
+-- modemCLIDLogEntry .1.4.1
+-- modemCLIDLogIndex .1.4.1.1
+-- modemCLIDLogNumber .1.4.1.2
+-- powerDistributionStatus .1.5
+-- pdConfig .1.5.1
+-- pdMain .1.5.2
+-- pdMainCurrent .1.5.2.1
+-- pdMainCurrentInEventState .1.5.2.1.2
+-- pdMainCurrentValue .1.5.2.1.3
+-- pdMainCurrentValueStr .1.5.2.1.4
+-- pdMainCurrentDeadband .1.5.2.1.10
+-- pdMainCurrentVHighCurrent .1.5.2.1.11
+-- pdMainCurrentHighCurrent .1.5.2.1.12
+-- pdMainCurrentLowCurrent .1.5.2.1.13
+-- pdMainCurrentVLowCurrent .1.5.2.1.14
+-- pdMainVoltage .1.5.2.2
+-- pdMainVoltageInEventState .1.5.2.2.2
+-- pdMainVoltageValue .1.5.2.2.3
+-- pdMainVoltageValueStr .1.5.2.2.4
+-- pdMainVoltageDeadband .1.5.2.2.10
+-- pdMainVoltageVHighVoltage .1.5.2.2.11
+-- pdMainVoltageHighVoltage .1.5.2.2.12
+-- pdMainVoltageLowVoltage .1.5.2.2.13
+-- pdMainVoltageVLowVoltage .1.5.2.2.14
+-- pdMainPower .1.5.2.3
+-- pdMainPowerValue .1.5.2.3.3
+-- pdMainPowerValueStr .1.5.2.3.4
+-- pdOutput .1.5.3
+-- pdOutputCurrentTable .1.5.3.1
+-- pdOutputCurrentEntry .1.5.3.1.1
+-- pdOutputCurrentIndex .1.5.3.1.1.1
+-- pdOutputCurrentInEventState .1.5.3.1.1.2
+-- pdOutputCurrentValue .1.5.3.1.1.3
+-- pdOutputCurrentValueStr .1.5.3.1.1.4
+-- pdOutputCurrentDeadband .1.5.3.1.1.10
+-- pdOutputCurrentVHighCurrent .1.5.3.1.1.11
+-- pdOutputCurrentHighCurrent .1.5.3.1.1.12
+-- pdOutputCurrentLowCurrent .1.5.3.1.1.13
+-- pdOutputCurrentVLowCurrent .1.5.3.1.1.14
+-- pdOutputFuseTable .1.5.3.4
+-- pdOutputFuseEntry .1.5.3.4.1
+-- pdOutputFuseIndex .1.5.3.4.1.1
+-- pdOutputFuseInEventState .1.5.3.4.1.2
+-- pdOutputFuseValueStr .1.5.3.4.1.4
+-- pdNextGen .1.5.4
+-- pdnTable .1.5.4.1
+-- pdnEntry .1.5.4.1.1
+-- pdnIndexPD .1.5.4.1.1.1
+-- pdnIndexOutput .1.5.4.1.1.2
+-- pdnConfig .1.5.4.1.1.3
+-- pdnMainCurrentInEventState .1.5.4.1.1.4
+-- pdnMainCurrentValue .1.5.4.1.1.5
+-- pdnMainCurrentValueStr .1.5.4.1.1.6
+-- pdnMainCurrentDeadband .1.5.4.1.1.7
+-- pdnMainCurrentVHighCurrent .1.5.4.1.1.8
+-- pdnMainCurrentHighCurrent .1.5.4.1.1.9
+-- pdnMainCurrentLowCurrent .1.5.4.1.1.10
+-- pdnMainCurrentVLowCurrent .1.5.4.1.1.11
+-- pdnMainVoltageInEventState .1.5.4.1.1.12
+-- pdnMainVoltageValue .1.5.4.1.1.13
+-- pdnMainVoltageValueStr .1.5.4.1.1.14
+-- pdnMainVoltageDeadband .1.5.4.1.1.15
+-- pdnMainVoltageVHighVoltage .1.5.4.1.1.16
+-- pdnMainVoltageHighVoltage .1.5.4.1.1.17
+-- pdnMainVoltageLowVoltage .1.5.4.1.1.18
+-- pdnMainVoltageVLowVoltage .1.5.4.1.1.19
+-- pdnMainPowerValue .1.5.4.1.1.20
+-- pdnMainPowerValueStr .1.5.4.1.1.21
+-- pdnOutputCurrentInEventState .1.5.4.1.1.22
+-- pdnOutputCurrentValue .1.5.4.1.1.23
+-- pdnOutputCurrentValueStr .1.5.4.1.1.24
+-- pdnOutputCurrentDeadband .1.5.4.1.1.25
+-- pdnOutputCurrentVHighCurrent .1.5.4.1.1.26
+-- pdnOutputCurrentHighCurrent .1.5.4.1.1.27
+-- pdnOutputCurrentLowCurrent .1.5.4.1.1.28
+-- pdnOutputCurrentVLowCurrent .1.5.4.1.1.29
+-- pdnOutputFuseInEventState .1.5.4.1.1.30
+-- pdnOutputFuseValueStr .1.5.4.1.1.31
+-- pdnMainCombinedStatus .1.5.4.1.1.32
+-- pdnOutputCombinedStatusBlock1 .1.5.4.1.1.33
+-- pdnOutputCombinedStatusBlock2 .1.5.4.1.1.34
+-- pdnDeviceCurrentValue .1.5.4.1.1.35
+-- pdnDeviceCurrentValueStr .1.5.4.1.1.36
+-- pdSystem .1.5.5
+-- pdSystemCurrent .1.5.5.1
+-- pdSystemPower .1.5.5.2
+-- fuelSensorStatus .1.6
+-- fsStatusTable .1.6.1
+-- fsStatusEntry .1.6.1.1
+-- fsStatusIndex .1.6.1.1.1
+-- fsStatusName .1.6.1.1.2
+-- fsStatusDeviceState .1.6.1.1.3
+-- fsStatusVolumeValueString .1.6.1.1.4
+-- fsStatusVolumePercentLevel .1.6.1.1.7
+-- fsStatusVolumeInEventState .1.6.1.1.8
+-- fsStatusCombined .1.6.1.1.9
+-- wirelessModemStatus .1.7
+-- wmsStatus .1.7.1
+-- wmsSignal .1.7.2
+-- wmsRSSI .1.7.3
+-- wmsBER .1.7.4
+-- wmsUpdated .1.7.5
+-- wmsRegistration .1.7.6
+-- wmsLAC .1.7.7
+-- wmsCellID .1.7.8
+-- wmsIMSI .1.7.9
+-- wmsPhnum .1.7.10
+-- wmsLocalIP .1.7.11
+-- wmsMgfID .1.7.12
+-- wmsModelID .1.7.13
+-- wmsIMEI .1.7.14
+-- wmsRevID .1.7.15
+-- wmsNetName .1.7.16
+-- wmsGPRSStatus .1.7.17
+-- wmsBand .1.7.18
+-- wmsChannel .1.7.19
+-- wmsCountryCode .1.7.20
+-- wmsNetCode .1.7.21
+-- wmsPLMNColor .1.7.22
+-- wmsBScolor .1.7.23
+-- wmsMpRACH .1.7.24
+-- wmsMinRxLevel .1.7.25
+-- wmsBaseCoeff .1.7.26
+-- wmsSIMStatus .1.7.27
+-- wmsICCID .1.7.28
+-- wmsModemType .1.7.29
+-- acPowerMonitorStatus .1.8
+-- acpmStatusTable .1.8.1
+-- acpmStatusEntry .1.8.1.1
+-- acpmsIndex .1.8.1.1.1
+-- acpmsName .1.8.1.1.2
+-- acpmsAvgVoltageValueStr .1.8.1.1.3
+-- acpmsAvgVoltageMinStr .1.8.1.1.4
+-- acpmsAvgVoltageMaxStr .1.8.1.1.5
+-- acpmsAvgVoltageAvgStr .1.8.1.1.6
+-- acpmsAvgVoltageInEventState .1.8.1.1.7
+-- acpmsVoltagePhaseAValueStr .1.8.1.1.8
+-- acpmsVoltagePhaseBValueStr .1.8.1.1.9
+-- acpmsVoltagePhaseCValueStr .1.8.1.1.10
+-- acpmsAvgCurrentValueStr .1.8.1.1.11
+-- acpmsAvgCurrentMinStr .1.8.1.1.12
+-- acpmsAvgCurrentMaxStr .1.8.1.1.13
+-- acpmsAvgCurrentAvgStr .1.8.1.1.14
+-- acpmsAvgCurrentInEventState .1.8.1.1.15
+-- acpmsCurrentPhaseAValueStr .1.8.1.1.16
+-- acpmsCurrentPhaseBValueStr .1.8.1.1.17
+-- acpmsCurrentPhaseCValueStr .1.8.1.1.18
+-- acpmsFreqValueStr .1.8.1.1.19
+-- acpmsFreqMinStr .1.8.1.1.20
+-- acpmsFreqMaxStr .1.8.1.1.21
+-- acpmsFreqAvgStr .1.8.1.1.22
+-- acpmsFreqInEventState .1.8.1.1.23
+-- acpmsTRPValueStr .1.8.1.1.24
+-- acpmsTRPMinStr .1.8.1.1.25
+-- acpmsTRPMaxStr .1.8.1.1.26
+-- acpmsTRPAvgStr .1.8.1.1.27
+-- acpmsTRPInEventState .1.8.1.1.28
+-- acpmsRPPhaseAValueStr .1.8.1.1.29
+-- acpmsRPPhaseBValueStr .1.8.1.1.30
+-- acpmsRPPhaseCValueStr .1.8.1.1.31
+-- acpmsCombined .1.8.1.1.32
+-- acpmsTPFValueStr .1.8.1.1.33
+-- acpmsTPFMinStr .1.8.1.1.34
+-- acpmsTPFMaxStr .1.8.1.1.35
+-- acpmsTPFAvgStr .1.8.1.1.36
+-- acpmsTPFInEventState .1.8.1.1.37
+-- acpmsPFPhaseAValueStr .1.8.1.1.38
+-- acpmsPFPhaseBValueStr .1.8.1.1.39
+-- acpmsPFPhaseCValueStr .1.8.1.1.40
+-- acpmsTRcPValueStr .1.8.1.1.41
+-- acpmsTRcPMinStr .1.8.1.1.42
+-- acpmsTRcPMaxStr .1.8.1.1.43
+-- acpmsTRcPAvgStr .1.8.1.1.44
+-- acpmsRcPPhaseAValueStr .1.8.1.1.45
+-- acpmsRcPPhaseBValueStr .1.8.1.1.46
+-- acpmsRcPPhaseCValueStr .1.8.1.1.47
+-- acpmsTAPValueStr .1.8.1.1.48
+-- acpmsTAPMinStr .1.8.1.1.49
+-- acpmsTAPMaxStr .1.8.1.1.50
+-- acpmsTAPAvgStr .1.8.1.1.51
+-- acpmsAPPhaseAValueStr .1.8.1.1.52
+-- acpmsAPPhaseBValueStr .1.8.1.1.53
+-- acpmsAPPhaseCValueStr .1.8.1.1.54
+-- acpmsTotalEnergyWh .1.8.1.1.55
+-- acpmsTotalEnergyVAR .1.8.1.1.56
+-- acpmsTotalEnergyVA .1.8.1.1.57
+-- aisgStatus .1.9
+-- aisgsPower .1.9.1
+-- aisgsBaseStationID .1.9.2
+-- aisgsALDTable .1.9.3
+-- aisgsALDEntry .1.9.3.1
+-- aisgsALDIndex .1.9.3.1.1
+-- aisgsALDSectorID .1.9.3.1.2
+-- aisgsALDType .1.9.3.1.3
+-- aisgsALDDescription .1.9.3.1.4
+-- aisgsALDStatus .1.9.3.1.5
+-- aisgsALDID .1.9.3.1.6
+-- aisgsALDTilt .1.9.3.1.7
+-- aisgsALDHwVersion .1.9.3.1.8
+-- aisgsALDSwVersion .1.9.3.1.9
+-- aisgsALDModel .1.9.3.1.10
+-- aisgsALDAntennaModel .1.9.3.1.11
+-- aisgsALDMinTilt .1.9.3.1.12
+-- aisgsALDMaxTilt .1.9.3.1.13
+-- aisgsALDAISGVersion .1.9.3.1.14
+-- aisgsFileTable .1.9.4
+-- aisgsFileEntry .1.9.4.1
+-- aisgsFileIndex .1.9.4.1.1
+-- aisgsFileName .1.9.4.1.2
+-- aisgsFileType .1.9.4.1.3
+-- aisgsFileVersion .1.9.4.1.4
+-- aisgsAutoTable .1.9.5
+-- aisgsAutoEntry .1.9.5.1
+-- aisgsAutoIndex .1.9.5.1.1
+-- aisgsAutoVendor .1.9.5.1.2
+-- aisgsAutoALDModel .1.9.5.1.3
+-- aisgsAutoSoftware .1.9.5.1.4
+-- aisgsAutoConfig .1.9.5.1.5
+-- aisgsAutoTilt .1.9.5.1.6
+-- aisgsAAATable .1.9.6
+-- aisgsAAAEntry .1.9.6.1
+-- aisgsAAAIndex .1.9.6.1.1
+-- aisgsAAAALDID .1.9.6.1.2
+-- aisgsAAAAntennaSN .1.9.6.1.3
+-- aisgsAAASectorID .1.9.6.1.4
+
+-- config .2
+-- eventSensorBasics .2.1
+-- esNumberEventSensors .2.1.1
+-- esTable .2.1.2
+-- esEntry .2.1.2.1
+-- esIndex .2.1.2.1.1
+-- esName .2.1.2.1.2
+-- esID .2.1.2.1.3
+-- esNumberTempSensors .2.1.2.1.4
+-- esTempReportingMode .2.1.2.1.5
+-- esNumberCCs .2.1.2.1.6
+-- esCCReportingMode .2.1.2.1.7
+-- esNumberHumidSensors .2.1.2.1.8
+-- esHumidReportingMode .2.1.2.1.9
+-- esNumberNoiseSensors .2.1.2.1.10
+-- esNoiseReportingMode .2.1.2.1.11
+-- esNumberAirflowSensors .2.1.2.1.12
+-- esAirflowReportingMode .2.1.2.1.13
+-- esNumberAnalog .2.1.2.1.14
+-- esAnalogReportingMode .2.1.2.1.15
+-- esNumberOutputs .2.1.2.1.16
+-- esOutputReportingMode .2.1.2.1.17
+-- esTempCombinedStatus .2.1.2.1.18
+-- esCCCombinedStatusBlock1 .2.1.2.1.19
+-- esCCCombinedStatusBlock2 .2.1.2.1.20
+-- esCCCombinedStatusBlock3 .2.1.2.1.21
+-- esCCCombinedStatusBlock4 .2.1.2.1.22
+-- esCCCombinedStatusBlock5 .2.1.2.1.23
+-- esCCCombinedStatusBlock6 .2.1.2.1.24
+-- esCCCombinedStatusBlock7 .2.1.2.1.25
+-- esCCCombinedStatusBlock8 .2.1.2.1.26
+-- esHumidCombinedStatus .2.1.2.1.27
+-- esAnalogCombinedStatusBlock1 .2.1.2.1.28
+-- esAnalogCombinedStatusBlock2 .2.1.2.1.29
+-- esAnalogCombinedStatusBlock3 .2.1.2.1.30
+-- esAnalogCombinedStatusBlock4 .2.1.2.1.31
+-- esAnalogCombinedStatusBlock5 .2.1.2.1.32
+-- esAnalogCombinedStatusBlock6 .2.1.2.1.33
+-- esOutputCombinedStatusBlock1 .2.1.2.1.34
+-- esOutputCombinedStatusBlock2 .2.1.2.1.35
+-- esNewSensors .2.1.3
+-- eventSensorPointConfig .2.2
+-- esPointConfigTempTable .2.2.1
+-- esPointConfigTempEntry .2.2.1.1
+-- espcTempIndexES .2.2.1.1.1
+-- espcTempIndexPoint .2.2.1.1.2
+-- espcTempEnable .2.2.1.1.3
+-- espcTempScale .2.2.1.1.4
+-- espcTempDeadband .2.2.1.1.5
+-- espcTempVHighTemp .2.2.1.1.6
+-- espcTempVHighActions .2.2.1.1.7
+-- espcTempVHighTrapnum .2.2.1.1.8
+-- espcTempVHighClass .2.2.1.1.9
+-- espcTempHighTemp .2.2.1.1.10
+-- espcTempHighActions .2.2.1.1.11
+-- espcTempHighTrapnum .2.2.1.1.12
+-- espcTempHighClass .2.2.1.1.13
+-- espcTempNormalActions .2.2.1.1.14
+-- espcTempNormalTrapnum .2.2.1.1.15
+-- espcTempNormalClass .2.2.1.1.16
+-- espcTempLowTemp .2.2.1.1.17
+-- espcTempLowActions .2.2.1.1.18
+-- espcTempLowTrapnum .2.2.1.1.19
+-- espcTempLowClass .2.2.1.1.20
+-- espcTempVLowTemp .2.2.1.1.21
+-- espcTempVLowActions .2.2.1.1.22
+-- espcTempVLowTrapnum .2.2.1.1.23
+-- espcTempVLowClass .2.2.1.1.24
+-- esPointConfigCCTable .2.2.2
+-- esPointConfigCCEntry .2.2.2.1
+-- espcCCIndexES .2.2.2.1.1
+-- espcCCIndexPoint .2.2.2.1.2
+-- espcCCEnable .2.2.2.1.3
+-- espcCCName .2.2.2.1.4
+-- espcCCEventState .2.2.2.1.5
+-- espcCCThreshold .2.2.2.1.6
+-- espcCCEventActions .2.2.2.1.7
+-- espcCCEventTrapnum .2.2.2.1.8
+-- espcCCEventClass .2.2.2.1.9
+-- espcCCNormalActions .2.2.2.1.10
+-- espcCCNormalTrapnum .2.2.2.1.11
+-- espcCCNormalClass .2.2.2.1.12
+-- espcCCAlarmAlias .2.2.2.1.13
+-- espcCCNormalAlias .2.2.2.1.14
+-- espcCCNormalThreshold .2.2.2.1.15
+-- espcCCOverrideGlobalReminder .2.2.2.1.16
+-- espcCCReminderInterval .2.2.2.1.17
+-- esPointConfigHumidTable .2.2.3
+-- esPointConfigHumidEntry .2.2.3.1
+-- espcHumidIndexES .2.2.3.1.1
+-- espcHumidIndexPoint .2.2.3.1.2
+-- espcHumidEnable .2.2.3.1.3
+-- espcHumidDeadband .2.2.3.1.4
+-- espcHumidVHighHumid .2.2.3.1.5
+-- espcHumidVHighActions .2.2.3.1.6
+-- espcHumidVHighTrapnum .2.2.3.1.7
+-- espcHumidVHighClass .2.2.3.1.8
+-- espcHumidHighHumid .2.2.3.1.9
+-- espcHumidHighActions .2.2.3.1.10
+-- espcHumidHighTrapnum .2.2.3.1.11
+-- espcHumidHighClass .2.2.3.1.12
+-- espcHumidNormalActions .2.2.3.1.13
+-- espcHumidNormalTrapnum .2.2.3.1.14
+-- espcHumidNormalClass .2.2.3.1.15
+-- espcHumidLowHumid .2.2.3.1.16
+-- espcHumidLowActions .2.2.3.1.17
+-- espcHumidLowTrapnum .2.2.3.1.18
+-- espcHumidLowClass .2.2.3.1.19
+-- espcHumidVLowHumid .2.2.3.1.20
+-- espcHumidVLowActions .2.2.3.1.21
+-- espcHumidVLowTrapnum .2.2.3.1.22
+-- espcHumidVLowClass .2.2.3.1.23
+-- esPointConfigAITable .2.2.5
+-- esPointConfigAIEntry .2.2.5.1
+-- espcAIIndexES .2.2.5.1.1
+-- espcAIIndexPoint .2.2.5.1.2
+-- espcAIEnable .2.2.5.1.3
+-- espcAIDeadband .2.2.5.1.5
+-- espcAIVhighValue .2.2.5.1.6
+-- espcAIVhighActions .2.2.5.1.7
+-- espcAIVhighTrapnum .2.2.5.1.8
+-- espcAIVhighClass .2.2.5.1.9
+-- espcAIHighValue .2.2.5.1.10
+-- espcAIHighActions .2.2.5.1.11
+-- espcAIHighTrapnum .2.2.5.1.12
+-- espcAIHighClass .2.2.5.1.13
+-- espcAINormalActions .2.2.5.1.14
+-- espcAINormalTrapnum .2.2.5.1.15
+-- espcAINormalClass .2.2.5.1.16
+-- espcAILowValue .2.2.5.1.17
+-- espcAILowActions .2.2.5.1.18
+-- espcAILowTrapnum .2.2.5.1.19
+-- espcAILowClass .2.2.5.1.20
+-- espcAIVlowValue .2.2.5.1.21
+-- espcAIVlowActions .2.2.5.1.22
+-- espcAIVlowTrapnum .2.2.5.1.23
+-- espcAIVlowClass .2.2.5.1.24
+-- espcAIConvUnitName .2.2.5.1.25
+-- espcAIConvHighValue .2.2.5.1.26
+-- espcAIConvHighUnit .2.2.5.1.27
+-- espcAIConvLowValue .2.2.5.1.29
+-- espcAIConvLowUnit .2.2.5.1.30
+-- espcAIDisplayFormat .2.2.5.1.32
+-- esPointConfigOutputTable .2.2.6
+-- esPointConfigOutputEntry .2.2.6.1
+-- espcOutputIndexES .2.2.6.1.1
+-- espcOutputIndexPoint .2.2.6.1.2
+-- espcOutputEnable .2.2.6.1.3
+-- espcOutputActiveState .2.2.6.1.4
+-- espcOutputType .2.2.6.1.5
+-- espcOutputAliasValue .2.2.6.1.6
+-- espcOutputAliasColor .2.2.6.1.7
+-- espcOutputActiveAlias .2.2.6.1.10
+-- espcOutputActiveColor .2.2.6.1.11
+-- espcOutputActiveActions .2.2.6.1.12
+-- espcOutputActiveTrapnum .2.2.6.1.13
+-- espcOutputActiveClass .2.2.6.1.14
+-- espcOutputInactiveAlias .2.2.6.1.20
+-- espcOutputInactiveColor .2.2.6.1.21
+-- espcOutputInactiveActions .2.2.6.1.22
+-- espcOutputInactiveTrapnum .2.2.6.1.23
+-- espcOutputInactiveClass .2.2.6.1.24
+-- serialPorts .2.3
+-- numberPorts .2.3.1
+-- portConfigTable .2.3.2
+-- portConfigEntry .2.3.2.1
+-- portConfigIndex .2.3.2.1.1
+-- portConfigBaud .2.3.2.1.2
+-- portConfigDataFormat .2.3.2.1.3
+-- portConfigStripPtOutputLfs .2.3.2.1.4
+-- portConfigStripPtInputLfs .2.3.2.1.5
+-- portConfigMaskEnable .2.3.2.1.7
+-- portConfigDAEnable .2.3.2.1.8
+-- portConfigStoreAlarmsDPT .2.3.2.1.9
+-- portConfigRecordTimeout .2.3.2.1.10
+-- portConfigDataType .2.3.2.1.11
+-- portConfigEtxToCRLF .2.3.2.1.12
+-- portConfigMLREnable .2.3.2.1.13
+-- portConfigMLRStartField1Pos .2.3.2.1.14
+-- portConfigMLRStartField1Text .2.3.2.1.15
+-- portConfigMLRStartField2Pos .2.3.2.1.16
+-- portConfigMLRStartField2Text .2.3.2.1.17
+-- portConfigMLRNumLinesBefore .2.3.2.1.18
+-- portConfigMLREndDetection .2.3.2.1.19
+-- portConfigMLRLineCount .2.3.2.1.20
+-- portConfigMLREndField1Pos .2.3.2.1.21
+-- portConfigMLREndField1Text .2.3.2.1.22
+-- portConfigMLREndField2Pos .2.3.2.1.23
+-- portConfigMLREndField2Text .2.3.2.1.24
+-- portConfigMLRUseComplexRules .2.3.2.1.25
+-- portConfigBufferPT .2.3.2.1.26
+-- portConfigId .2.3.2.1.27
+-- portConfigMode .2.3.2.1.28
+-- portConfigHsk .2.3.2.1.29
+-- network .2.4
+-- interface .2.4.1
+-- ethernet .2.4.1.1
+-- ethernet1 .2.4.1.1.1
+-- eth1Mode .2.4.1.1.1.1
+-- eth1Address .2.4.1.1.1.2
+-- eth1SubnetMask .2.4.1.1.1.3
+-- eth1Router .2.4.1.1.1.4
+-- eth1VLAN .2.4.1.1.1.5
+-- eth1VLAN1 .2.4.1.1.1.5.1
+-- eth1VLAN1ID .2.4.1.1.1.5.1.1
+-- eth1VLAN1Priority .2.4.1.1.1.5.1.2
+-- eth1VLAN1Address .2.4.1.1.1.5.1.3
+-- eth1VLAN1SubnetMask .2.4.1.1.1.5.1.4
+-- eth1VLAN1Router .2.4.1.1.1.5.1.5
+-- eth1VLAN2 .2.4.1.1.1.5.2
+-- eth1VLAN2ID .2.4.1.1.1.5.2.1
+-- eth1VLAN2Priority .2.4.1.1.1.5.2.2
+-- eth1VLAN2Address .2.4.1.1.1.5.2.3
+-- eth1VLAN2SubnetMask .2.4.1.1.1.5.2.4
+-- eth1VLAN2Router .2.4.1.1.1.5.2.5
+-- eth1VLAN3 .2.4.1.1.1.5.3
+-- eth1VLAN3ID .2.4.1.1.1.5.3.1
+-- eth1VLAN3Priority .2.4.1.1.1.5.3.2
+-- eth1VLAN3Address .2.4.1.1.1.5.3.3
+-- eth1VLAN3SubnetMask .2.4.1.1.1.5.3.4
+-- eth1VLAN3Router .2.4.1.1.1.5.3.5
+-- eth1VLAN4 .2.4.1.1.1.5.4
+-- eth1VLAN4ID .2.4.1.1.1.5.4.1
+-- eth1VLAN4Priority .2.4.1.1.1.5.4.2
+-- eth1VLAN4Address .2.4.1.1.1.5.4.3
+-- eth1VLAN4SubnetMask .2.4.1.1.1.5.4.4
+-- eth1VLAN4Router .2.4.1.1.1.5.4.5
+-- eth1VLAN5 .2.4.1.1.1.5.5
+-- eth1VLAN5ID .2.4.1.1.1.5.5.1
+-- eth1VLAN5Priority .2.4.1.1.1.5.5.2
+-- eth1VLAN5Address .2.4.1.1.1.5.5.3
+-- eth1VLAN5SubnetMask .2.4.1.1.1.5.5.4
+-- eth1VLAN5Router .2.4.1.1.1.5.5.5
+-- eth1VLAN6 .2.4.1.1.1.5.6
+-- eth1VLAN6ID .2.4.1.1.1.5.6.1
+-- eth1VLAN6Priority .2.4.1.1.1.5.6.2
+-- eth1VLAN6Address .2.4.1.1.1.5.6.3
+-- eth1VLAN6SubnetMask .2.4.1.1.1.5.6.4
+-- eth1VLAN6Router .2.4.1.1.1.5.6.5
+-- eth1MAC .2.4.1.1.1.6
+-- eth1IPv6 .2.4.1.1.1.7
+-- eth1IPv6Mode .2.4.1.1.1.7.1
+-- eth1IPv6Static .2.4.1.1.1.7.2
+-- eth1IPv6StaticAddress .2.4.1.1.1.7.2.1
+-- eth1IPv6StaticRouter .2.4.1.1.1.7.2.2
+-- eth1IPv6Auto .2.4.1.1.1.7.3
+-- eth1IPv6AutoAddress1 .2.4.1.1.1.7.3.1
+-- eth1IPv6AutoAddress2 .2.4.1.1.1.7.3.2
+-- eth1IPv6AutoAddress3 .2.4.1.1.1.7.3.3
+-- eth1IPv6AutoAddress4 .2.4.1.1.1.7.3.4
+-- eth1IPv6LinkLocalAddress .2.4.1.1.1.7.4
+-- ethernet2 .2.4.1.1.2
+-- eth2Mode .2.4.1.1.2.1
+-- eth2Address .2.4.1.1.2.2
+-- eth2SubnetMask .2.4.1.1.2.3
+-- eth2Router .2.4.1.1.2.4
+-- eth2VLAN .2.4.1.1.2.5
+-- eth2VLAN1 .2.4.1.1.2.5.1
+-- eth2VLAN1ID .2.4.1.1.2.5.1.1
+-- eth2VLAN1Priority .2.4.1.1.2.5.1.2
+-- eth2VLAN1Address .2.4.1.1.2.5.1.3
+-- eth2VLAN1SubnetMask .2.4.1.1.2.5.1.4
+-- eth2VLAN1Router .2.4.1.1.2.5.1.5
+-- eth2VLAN2 .2.4.1.1.2.5.2
+-- eth2VLAN2ID .2.4.1.1.2.5.2.1
+-- eth2VLAN2Priority .2.4.1.1.2.5.2.2
+-- eth2VLAN2Address .2.4.1.1.2.5.2.3
+-- eth2VLAN2SubnetMask .2.4.1.1.2.5.2.4
+-- eth2VLAN2Router .2.4.1.1.2.5.2.5
+-- eth2VLAN3 .2.4.1.1.2.5.3
+-- eth2VLAN3ID .2.4.1.1.2.5.3.1
+-- eth2VLAN3Priority .2.4.1.1.2.5.3.2
+-- eth2VLAN3Address .2.4.1.1.2.5.3.3
+-- eth2VLAN3SubnetMask .2.4.1.1.2.5.3.4
+-- eth2VLAN3Router .2.4.1.1.2.5.3.5
+-- eth2VLAN4 .2.4.1.1.2.5.4
+-- eth2VLAN4ID .2.4.1.1.2.5.4.1
+-- eth2VLAN4Priority .2.4.1.1.2.5.4.2
+-- eth2VLAN4Address .2.4.1.1.2.5.4.3
+-- eth2VLAN4SubnetMask .2.4.1.1.2.5.4.4
+-- eth2VLAN4Router .2.4.1.1.2.5.4.5
+-- eth2VLAN5 .2.4.1.1.2.5.5
+-- eth2VLAN5ID .2.4.1.1.2.5.5.1
+-- eth2VLAN5Priority .2.4.1.1.2.5.5.2
+-- eth2VLAN5Address .2.4.1.1.2.5.5.3
+-- eth2VLAN5SubnetMask .2.4.1.1.2.5.5.4
+-- eth2VLAN5Router .2.4.1.1.2.5.5.5
+-- eth2VLAN6 .2.4.1.1.2.5.6
+-- eth2VLAN6ID .2.4.1.1.2.5.6.1
+-- eth2VLAN6Priority .2.4.1.1.2.5.6.2
+-- eth2VLAN6Address .2.4.1.1.2.5.6.3
+-- eth2VLAN6SubnetMask .2.4.1.1.2.5.6.4
+-- eth2VLAN6Router .2.4.1.1.2.5.6.5
+-- eth2MAC .2.4.1.1.2.6
+-- eth2IPv6 .2.4.1.1.2.7
+-- eth2IPv6Mode .2.4.1.1.2.7.1
+-- eth2IPv6Static .2.4.1.1.2.7.2
+-- eth2IPv6StaticAddress .2.4.1.1.2.7.2.1
+-- eth2IPv6StaticRouter .2.4.1.1.2.7.2.2
+-- eth2IPv6Auto .2.4.1.1.2.7.3
+-- eth2IPv6AutoAddress1 .2.4.1.1.2.7.3.1
+-- eth2IPv6AutoAddress2 .2.4.1.1.2.7.3.2
+-- eth2IPv6AutoAddress3 .2.4.1.1.2.7.3.3
+-- eth2IPv6AutoAddress4 .2.4.1.1.2.7.3.4
+-- eth2IPv6LinkLocalAddress .2.4.1.1.2.7.4
+-- defaultRouter .2.4.2
+-- dnsTable .2.4.3
+-- dnsEntry .2.4.3.1
+-- dnsIndex .2.4.3.1.1
+-- dnsAddress .2.4.3.1.2
+-- hostname .2.4.4
+-- hostTable .2.4.5
+-- hostEntry .2.4.5.1
+-- hostIndex .2.4.5.1.1
+-- hostDeclaration .2.4.5.1.2
+-- ncpDuplex .2.4.6
+-- ncpTimeout .2.4.7
+-- snmp .2.4.8
+-- snmpAgentEnable .2.4.8.1
+-- snmpNotificationCaptureEnable .2.4.8.5
+-- snmpNotificationCaptureFile .2.4.8.6
+-- snmpNotificationTx .2.4.8.7
+-- snmpNtfnAttempts .2.4.8.7.1
+-- snmpNtfnTimeout .2.4.8.7.2
+-- snmpNtfnCycles .2.4.8.7.3
+-- snmpNtfnSnooze .2.4.8.7.4
+-- snmpPoll .2.4.8.9
+-- snmpPMode .2.4.8.9.1
+-- snmpPBufferFile .2.4.8.9.2
+-- snmpPBufferAllPeriod .2.4.8.9.3
+-- snmpPRequestTable .2.4.8.9.4
+-- snmpPRequestEntry .2.4.8.9.4.1
+-- snmpPRequestIndex .2.4.8.9.4.1.1
+-- snmpPRequestDescription .2.4.8.9.4.1.2
+-- snmpPRequestAgent .2.4.8.9.4.1.3
+-- snmpPRequestReadcom .2.4.8.9.4.1.4
+-- snmpPRequestOID .2.4.8.9.4.1.5
+-- snmpPRequestPeriod .2.4.8.9.4.1.6
+-- snmpPRequestID .2.4.8.9.4.1.7
+-- snmpPRequestThreshold .2.4.8.9.4.1.8
+-- snmpPRequestResultStatus .2.4.8.9.4.1.10
+-- snmpPRequestResultValue .2.4.8.9.4.1.11
+-- snmpPRequestResultTime .2.4.8.9.4.1.12
+-- snmpPRequestResultType .2.4.8.9.4.1.13
+-- ftpPush .2.4.9
+-- ftpPushEnable .2.4.9.1
+-- ftpPushServer .2.4.9.2
+-- ftpPushAccount .2.4.9.5
+-- ftpPushDirectory .2.4.9.6
+-- ftpPushperiod .2.4.9.7
+-- ftpPushPushFileTable .2.4.9.8
+-- ftpPushPushFileEntry .2.4.9.8.1
+-- ftpPushPushFileIndex .2.4.9.8.1.1
+-- ftpPushPushFile .2.4.9.8.1.2
+-- ftpPushPushAudit .2.4.9.9
+-- ftpPushPushAlarms .2.4.9.10
+-- ftpPushRemoteFileTable .2.4.9.11
+-- ftpPushRemoteFileEntry .2.4.9.11.1
+-- ftpPushRemoteFileIndex .2.4.9.11.1.1
+-- ftpPushRemoteFileName .2.4.9.11.1.2
+-- ftpPushRemoteAlarmName .2.4.9.12
+-- ftpPushPassive .2.4.9.13
+-- ftpPushIncludeDate .2.4.9.14
+-- ftpPushIncludeTime .2.4.9.15
+-- ftpPushIncludeSeq .2.4.9.16
+-- ftpPushPermissions .2.4.9.17
+-- ppp .2.4.10
+-- pppDial .2.4.10.1
+-- pppDialEnable .2.4.10.1.1
+-- pppDialNumber .2.4.10.1.2
+-- pppDialIdleTimeout .2.4.10.1.5
+-- pppDialRetries .2.4.10.1.6
+-- pppDialCDTimeout .2.4.10.1.7
+-- pppDialLoginTimeout .2.4.10.1.8
+-- pppDialMdmInit .2.4.10.1.9
+-- pppDialSuggestIP .2.4.10.1.10
+-- pppDialPlainLogin .2.4.10.1.11
+-- pppHost .2.4.10.2
+-- pppHostEnable .2.4.10.2.1
+-- pppHostIdleTimeout .2.4.10.2.2
+-- pppHostLocalIP .2.4.10.2.3
+-- pppHostRemoteIP .2.4.10.2.4
+-- routing .2.4.11
+-- pppRoutingEnable .2.4.11.1
+-- ethRoutingEnable .2.4.11.2
+-- ethRoutingNATEnable .2.4.11.3
+-- routingInterface .2.4.11.4
+-- eth2WanRoutingEnable .2.4.11.5
+-- netSecurity .2.4.12
+-- ipRestriction .2.4.12.1
+-- ipRestrictionTable .2.4.12.1.1
+-- ipRestrictionEntry .2.4.12.1.1.1
+-- ipRestrictionIndex .2.4.12.1.1.1.1
+-- ipRestrictionEnable .2.4.12.1.1.1.2
+-- ipRestrictionMask .2.4.12.1.1.1.3
+-- rts .2.4.13
+-- rtsFileTable .2.4.13.1
+-- rtsFileEntry .2.4.13.1.1
+-- rtsFileIndex .2.4.13.1.1.1
+-- rtsFileMode .2.4.13.1.1.2
+-- rtsFileShowAnswer .2.4.13.1.1.3
+-- rtsFileReqXON .2.4.13.1.1.4
+-- rtsFileTimeout .2.4.13.1.1.5
+-- rtsFileEmptyClose .2.4.13.1.1.6
+-- rtsFilePushHost .2.4.13.1.1.7
+-- rtsFilePushPort .2.4.13.1.1.8
+-- rtsFilePushRetryTimer .2.4.13.1.1.9
+-- rtsAlarms .2.4.13.2
+-- rtsAlarmsMode .2.4.13.2.1
+-- rtsAlarmsShowAnswer .2.4.13.2.2
+-- rtsAlarmsReqXON .2.4.13.2.3
+-- rtsAlarmsTimeout .2.4.13.2.4
+-- rtsAlarmsEmptyClose .2.4.13.2.5
+-- rtsAlarmsPushHost .2.4.13.2.6
+-- rtsAlarmsPushPort .2.4.13.2.7
+-- rtsAlarmsPushRetryTimer .2.4.13.2.8
+-- trap .2.4.14
+-- trapInclude .2.4.14.1
+-- trapIncludeDateTime .2.4.14.1.1
+-- trapIncludeSiteName .2.4.14.1.2
+-- trapIncludeSensorID .2.4.14.1.3
+-- trapIncludeUDName .2.4.14.1.4
+-- trapIncludeUDState .2.4.14.1.5
+-- trapIncludeSourceAddress .2.4.14.1.6
+-- trapAuthFailEnable .2.4.14.2
+-- routeTest .2.4.15
+-- routeTestEnable .2.4.15.1
+-- routeTestPeriod .2.4.15.2
+-- routeTestAddressTable .2.4.15.3
+-- routeTestAddressEntry .2.4.15.3.1
+-- routeTestAddressIndex .2.4.15.3.1.1
+-- routeTestAddress .2.4.15.3.1.2
+-- wireless .2.4.16
+-- wirelessMode .2.4.16.1
+-- wirelessAPN .2.4.16.2
+-- wirelessIdleTimeout .2.4.16.3
+-- wirelessDRE .2.4.16.9
+-- wirelessPPPUsername .2.4.16.10
+-- wirelessFirewall .2.4.16.11
+-- wirelessKeepaliveThreshold .2.4.16.12
+-- wirelessPPPDebug .2.4.16.13
+-- wirelessConnectivity .2.4.16.20
+-- wirelessConnEnable .2.4.16.20.1
+-- wirelessConnCheckInterval .2.4.16.20.2
+-- wirelessConnFailThreshold .2.4.16.20.3
+-- wirelessConnIP1 .2.4.16.20.10
+-- wirelessConnIP2 .2.4.16.20.11
+-- email .2.4.17
+-- emailServer .2.4.17.1
+-- emailDomain .2.4.17.2
+-- emailAuthEnable .2.4.17.3
+-- netAdvanced .2.4.18
+-- arpFilter .2.4.18.1
+-- web .2.4.19
+-- webEnable .2.4.19.1
+-- webPort .2.4.19.1
+-- webTimeout .2.4.19.1
+-- ipv6 .2.4.21
+-- ipv6DefaultRouter .2.4.21.1
+-- cpe .2.4.22
+-- cpeTable .2.4.22.1
+-- cpeEntry .2.4.22.1.1
+-- cpeIndex .2.4.22.1.1.1
+-- cpeHost .2.4.22.1.1.2
+-- cpeName .2.4.22.1.1.3
+-- cpeDescription .2.4.22.1.1.4
+-- cpeKeepalive .2.4.22.1.1.5
+-- cpeThreshold .2.4.22.1.1.6
+-- cpeEventReminderInterval .2.4.22.1.1.7
+-- cpeKeepaliveTicks .2.4.22.1.1.20
+-- cpePingSize .2.4.22.1.1.21
+-- cpeInfoReset .2.4.22.1.1.30
+-- cpeInfoNumReq .2.4.22.1.1.31
+-- cpeInfoNumGoodResp .2.4.22.1.1.32
+-- cpeInfoNumBadResp .2.4.22.1.1.33
+-- cpeInfoNumLostResp .2.4.22.1.1.34
+-- cpeInfoPercentLoss .2.4.22.1.1.35
+-- cpeInfoPercentBad .2.4.22.1.1.36
+-- modem .2.5
+-- modemFormat .2.5.1
+-- modemInitString .2.5.2
+-- modemCallAttempts .2.5.4
+-- modemCallDelay .2.5.5
+-- modemCmdTimout .2.5.6
+-- modemGoto .2.5.7
+-- modemClid .2.5.8
+-- modemCLIDEnable .2.5.8.1
+-- modemCLIDNumberTable .2.5.8.2
+-- modemCLIDNumberEntry .2.5.8.2.1
+-- modemCLIDNumberIndex .2.5.8.2.1.1
+-- modemCLIDNumber .2.5.8.2.1.2
+-- modemTAPInitString .2.5.9
+-- modemTAP8N1 .2.5.10
+-- time .2.8
+-- clock .2.8.1
+-- console .2.10
+-- consoleDuplex .2.10.1
+-- consoleTimeout .2.10.2
+-- consoleBaud .2.10.4
+-- consoleFormat .2.10.5
+-- consoleHsk .2.10.6
+-- consoleConfirm .2.10.7
+-- unitSecurity .2.11
+-- secCore .2.11.1
+-- scShowPasswordPrompt .2.11.1.1
+-- scConsoleLoginRequired .2.11.1.2
+-- scModemLoginRequired .2.11.1.3
+-- scTelnetLoginRequired .2.11.1.4
+-- scTelnetPTLoginRequired .2.11.1.5
+-- scRTSLoginRequired .2.11.1.6
+-- scAuthMode .2.11.1.7
+-- scRightsGroup .2.11.1.8
+-- secUserTable .2.11.2
+-- secUserEntry .2.11.2.1
+-- secUserIndex .2.11.2.1.1
+-- secUserEnable .2.11.2.1.2
+-- secUserConnectVia .2.11.2.1.5
+-- secUserLoginTo .2.11.2.1.6
+-- secUserAccessFile .2.11.2.1.7
+-- secUserPTEscapeTo .2.11.2.1.9
+-- secUserPPPType .2.11.2.1.10
+-- secUserRights .2.11.2.1.11
+-- secUserEventsReadAccess .2.11.2.1.13
+-- secUserAuditReadAccess .2.11.2.1.14
+-- secUserEventsWriteAccess .2.11.2.1.16
+-- secUserAuditWriteAccess .2.11.2.1.17
+-- secUserExpiration .2.11.2.1.18
+-- secUserCallbackNumber1 .2.11.2.1.19
+-- secUserCallbackNumber2 .2.11.2.1.20
+-- secUserCallbackNumber3 .2.11.2.1.21
+-- secUserChallengeTelnetMode .2.11.2.1.22
+-- secUserChallengeModemMode .2.11.2.1.23
+-- secUserChallengeConsoleMode .2.11.2.1.24
+-- secUserChallengeTelnetSendTo .2.11.2.1.25
+-- secUserChallengeModemSendTo .2.11.2.1.26
+-- secUserChallengeExpiration .2.11.2.1.27
+-- secFactory .2.11.3
+-- sfEnable .2.11.3.1
+-- sfSecret .2.11.3.2
+-- secSSH .2.11.4
+-- secVPN .2.11.5
+-- event .2.12
+-- evCore .2.12.1
+-- evClassNameTable .2.12.1.1
+-- evClassNameEntry .2.12.1.1.1
+-- evClassNameIndex .2.12.1.1.1.1
+-- evClassName .2.12.1.1.1.2
+-- evReminderInterval .2.12.1.2
+-- evLog .2.12.1.3
+-- evLogEnable .2.12.1.3.1
+-- evLogStoreAlarm .2.12.1.3.2
+-- evLogMaxSize .2.12.1.3.3
+-- evLogStoreSensor .2.12.1.3.4
+-- evLogTimeStampAlarms .2.12.1.3.5
+-- evLogPrependName .2.12.1.3.6
+-- evMgmt .2.12.1.4
+-- evMgmtReprocess .2.12.1.4.3
+-- evData .2.12.2
+-- evdCore .2.12.2.1
+-- evdExitOnTrue .2.12.2.1.1
+-- evdFilterAction .2.12.2.1.2
+-- evdWildCardChar .2.12.2.1.3
+-- evdTable .2.12.2.2
+-- evdEntry .2.12.2.2.1
+-- evdIndex .2.12.2.2.1.1
+-- evdEnable .2.12.2.2.1.2
+-- evdName .2.12.2.2.1.3
+-- evdEquation .2.12.2.2.1.4
+-- evdThreshold .2.12.2.2.1.5
+-- evdAutoclear .2.12.2.2.1.6
+-- evdClearInterval .2.12.2.2.1.7
+-- evdClearTime .2.12.2.2.1.8
+-- evdActions .2.12.2.2.1.9
+-- evdClass .2.12.2.2.1.10
+-- evdTrapNum .2.12.2.2.1.11
+-- evdMode .2.12.2.2.1.12
+-- evdFieldTable .2.12.2.3
+-- evdFieldEntry .2.12.2.3.1
+-- evdFieldIndex .2.12.2.3.1.1
+-- evdFieldStart .2.12.2.3.1.2
+-- evdFieldLength .2.12.2.3.1.3
+-- evdFieldName .2.12.2.3.1.4
+-- evdFieldLine .2.12.2.3.1.5
+-- evdFieldType .2.12.2.3.1.6
+-- evdMacroTable .2.12.2.4
+-- evdMacroEntry .2.12.2.4.1
+-- evdMacroIndex .2.12.2.4.1.1
+-- evdMacroName .2.12.2.4.1.2
+-- evdMacroEquation .2.12.2.4.1.3
+-- evNoData1 .2.12.3
+-- evNoData1Enable .2.12.3.1
+-- evNoData1Actions .2.12.3.2
+-- evNoData1Message .2.12.3.3
+-- evNoData1TrapNum .2.12.3.4
+-- evNoData1Class .2.12.3.5
+-- evNoData1Sched1Begin .2.12.3.6
+-- evNoData1Sched1End .2.12.3.7
+-- evNoData1Sched1Duration .2.12.3.8
+-- evNoData1Sched2Begin .2.12.3.9
+-- evNoData1Sched2End .2.12.3.10
+-- evNoData1Sched2Duration .2.12.3.11
+-- evNoData1PortEnableTable .2.12.3.12
+-- evNoData1PortEnableEntry .2.12.3.12.1
+-- evNoData1PortEnableIndex .2.12.3.12.1.1
+-- evNoData1PortEnable .2.12.3.12.1.2
+-- evNoData1Exclusions .2.12.3.13
+-- evNoData1Days .2.12.3.14
+-- evNoData2 .2.12.4
+-- evNoData2Enable .2.12.4.1
+-- evNoData2Actions .2.12.4.2
+-- evNoData2Message .2.12.4.3
+-- evNoData2TrapNum .2.12.4.4
+-- evNoData2Class .2.12.4.5
+-- evNoData2Sched1Begin .2.12.4.6
+-- evNoData2Sched1End .2.12.4.7
+-- evNoData2Sched1Duration .2.12.4.8
+-- evNoData2Sched2Begin .2.12.4.9
+-- evNoData2Sched2End .2.12.4.10
+-- evNoData2Sched2Duration .2.12.4.11
+-- evNoData2PortEnableTable .2.12.4.12
+-- evNoData2PortEnableEntry .2.12.4.12.1
+-- evNoData2PortEnableIndex .2.12.4.12.1.1
+-- evNoData2PortEnable .2.12.4.12.1.2
+-- evNoData2Exclusions .2.12.4.13
+-- evNoData2Days .2.12.4.14
+-- evSched1 .2.12.5
+-- evSched1Enable .2.12.5.1
+-- evSched1Actions .2.12.5.2
+-- evSched1Message .2.12.5.3
+-- evSched1TrapNum .2.12.5.4
+-- evSched1Class .2.12.5.5
+-- evSched1Sunday .2.12.5.6
+-- evSched1Monday .2.12.5.7
+-- evSched1Tuesday .2.12.5.8
+-- evSched1Wednesday .2.12.5.9
+-- evSched1Thursday .2.12.5.10
+-- evSched1Friday .2.12.5.11
+-- evSched1Saturday .2.12.5.12
+-- evSched1Exclusions .2.12.5.13
+-- evSched2 .2.12.6
+-- evSched2Enable .2.12.6.1
+-- evSched2Actions .2.12.6.2
+-- evSched2Message .2.12.6.3
+-- evSched2TrapNum .2.12.6.4
+-- evSched2Class .2.12.6.5
+-- evSched2Sunday .2.12.6.6
+-- evSched2Monday .2.12.6.7
+-- evSched2Tuesday .2.12.6.8
+-- evSched2Wednesday .2.12.6.9
+-- evSched2Thursday .2.12.6.10
+-- evSched2Friday .2.12.6.11
+-- evSched2Saturday .2.12.6.12
+-- evSched2Exclusions .2.12.6.13
+-- evShskLowTable .2.12.7
+-- evShskLowEntry .2.12.7.1
+-- evShskLowIndex .2.12.7.1.1
+-- evShskLowEnable .2.12.7.1.2
+-- evShskLowActions .2.12.7.1.3
+-- evShskLowMessage .2.12.7.1.4
+-- evShskLowClass .2.12.7.1.5
+-- evShskLowTrapNum .2.12.7.1.6
+-- evShskHighTable .2.12.8
+-- evShskHighEntry .2.12.8.1
+-- evShskHighIndex .2.12.8.1.1
+-- evShskHighEnable .2.12.8.1.2
+-- evShskHighActions .2.12.8.1.3
+-- evShskHighMessage .2.12.8.1.4
+-- evShskHighClass .2.12.8.1.5
+-- evShskHighTrapNum .2.12.8.1.6
+-- evNoSensor .2.12.9
+-- evNoSensorTimeout .2.12.9.1
+-- evNoSensorActions .2.12.9.2
+-- evNoSensorTrapNum .2.12.9.3
+-- evNoSensorClass .2.12.9.4
+-- fuelSensor .2.12.11
+-- fuelSensorGeneralTable .2.12.11.1
+-- fsGenEntry .2.12.11.1.1
+-- fsGenIndex .2.12.11.1.1.1
+-- fsGenName .2.12.11.1.1.2
+-- fsGenSensorType .2.12.11.1.1.3
+-- fsGenDistanceUnit .2.12.11.1.1.4
+-- fsGenRawValueTop .2.12.11.1.1.5
+-- fsGenTopOffset .2.12.11.1.1.6
+-- fsGenRawValueBottom .2.12.11.1.1.7
+-- fsGenBottomOffset .2.12.11.1.1.8
+-- fsGenInputES .2.12.11.1.1.9
+-- fsGenInputPoint .2.12.11.1.1.10
+-- fsGenFilterAveraging .2.12.11.1.1.11
+-- fsGenSysrepEnable .2.12.11.1.1.12
+-- fsGenSysrepThreshold .2.12.11.1.1.13
+-- fsGenSysrepLimit .2.12.11.1.1.14
+-- fsGenSysrepPackage .2.12.11.1.1.15
+-- fsGenSysrepType .2.12.11.1.1.16
+-- fsGenEnable .2.12.11.1.1.17
+-- fuelSensorTankTable .2.12.11.2
+-- fsTankEntry .2.12.11.2.1
+-- fsTankIndex .2.12.11.2.1.1
+-- fsTankHeight .2.12.11.2.1.2
+-- fsTankDimA .2.12.11.2.1.3
+-- fsTankDimB .2.12.11.2.1.4
+-- fsTankVolume .2.12.11.2.1.5
+-- fsTankVolumeUnit .2.12.11.2.1.6
+-- fsTankShape .2.12.11.2.1.7
+-- fuelSensorCustomTankTable .2.12.11.3
+-- fsCustomTankEntry .2.12.11.3.1
+-- fsCustomTankIndexFS .2.12.11.3.1.1
+-- fsCustomTankIndexDatum .2.12.11.3.1.2
+-- fsCustomTankHeight .2.12.11.3.1.3
+-- fsCustomTankVolume .2.12.11.3.1.4
+-- fuelSensorVolumeTable .2.12.11.4
+-- fsVolumeEntry .2.12.11.4.1
+-- fsVolumeIndex .2.12.11.4.1.1
+-- fsVolumeEnable .2.12.11.4.1.2
+-- fsVolumeDeadband .2.12.11.4.1.3
+-- fsVolumeVHighValue .2.12.11.4.1.4
+-- fsVolumeVHighActions .2.12.11.4.1.5
+-- fsVolumeVHighTrapNum .2.12.11.4.1.6
+-- fsVolumeVHighClass .2.12.11.4.1.7
+-- fsVolumeHighValue .2.12.11.4.1.8
+-- fsVolumeHighActions .2.12.11.4.1.9
+-- fsVolumeHighTrapNum .2.12.11.4.1.10
+-- fsVolumeHighClass .2.12.11.4.1.11
+-- fsVolumeNormalActions .2.12.11.4.1.12
+-- fsVolumeNormalTrapNum .2.12.11.4.1.13
+-- fsVolumeNormalClass .2.12.11.4.1.14
+-- fsVolumeLowValue .2.12.11.4.1.15
+-- fsVolumeLowActions .2.12.11.4.1.16
+-- fsVolumeLowTrapNum .2.12.11.4.1.17
+-- fsVolumeLowClass .2.12.11.4.1.18
+-- fsVolumeVLowValue .2.12.11.4.1.19
+-- fsVolumeVLowActions .2.12.11.4.1.20
+-- fsVolumeVLowTrapNum .2.12.11.4.1.21
+-- fsVolumeVLowClass .2.12.11.4.1.22
+-- fuelSensorDisconnectTable .2.12.11.5
+-- fsDiscEntry .2.12.11.5.1
+-- fsDiscIndex .2.12.11.5.1.1
+-- fsDiscEnable .2.12.11.5.1.2
+-- fsDiscHighValue .2.12.11.5.1.3
+-- fsDiscLowValue .2.12.11.5.1.4
+-- fsDiscActions .2.12.11.5.1.5
+-- fsDiscTrapNum .2.12.11.5.1.6
+-- fsDiscClass .2.12.11.5.1.7
+-- fsDiscNormalActions .2.12.11.5.1.8
+-- fsDiscNormalTrapNum .2.12.11.5.1.9
+-- fsDiscNormalClass .2.12.11.5.1.10
+-- acPowerMonitor .2.12.12
+-- acpmGeneralTable .2.12.12.1
+-- acpmGenEntry .2.12.12.1.1
+-- acpmGenIndex .2.12.12.1.1.1
+-- acpmGenDevice .2.12.12.1.1.2
+-- acpmGenName .2.12.12.1.1.3
+-- acpmGenAddress .2.12.12.1.1.4
+-- acpmGenPtRatio .2.12.12.1.1.5
+-- acpmGenCtRatio .2.12.12.1.1.6
+-- acpmGenPowerType .2.12.12.1.1.7
+-- acpmGenSysrepPackage .2.12.12.1.1.8
+-- acpmGenSysrepType .2.12.12.1.1.9
+-- acpmGenEnable .2.12.12.1.1.10
+-- acpmAvgVoltageTable .2.12.12.2
+-- acpmAvgVoltageEntry .2.12.12.2.1
+-- acpmAvgVoltageIndex .2.12.12.2.1.1
+-- acpmAvgVoltageEnable .2.12.12.2.1.2
+-- acpmAvgVoltageDeadband .2.12.12.2.1.3
+-- acpmAvgVoltageVHighValue .2.12.12.2.1.4
+-- acpmAvgVoltageVHighActions .2.12.12.2.1.5
+-- acpmAvgVoltageVHighTrapNum .2.12.12.2.1.6
+-- acpmAvgVoltageVHighClass .2.12.12.2.1.7
+-- acpmAvgVoltageHighValue .2.12.12.2.1.8
+-- acpmAvgVoltageHighActions .2.12.12.2.1.9
+-- acpmAvgVoltageHighTrapNum .2.12.12.2.1.10
+-- acpmAvgVoltageHighClass .2.12.12.2.1.11
+-- acpmAvgVoltageNormalActions .2.12.12.2.1.12
+-- acpmAvgVoltageNormalTrapNum .2.12.12.2.1.13
+-- acpmAvgVoltageNormalClass .2.12.12.2.1.14
+-- acpmAvgVoltageLowValue .2.12.12.2.1.15
+-- acpmAvgVoltageLowActions .2.12.12.2.1.16
+-- acpmAvgVoltageLowTrapNum .2.12.12.2.1.17
+-- acpmAvgVoltageLowClass .2.12.12.2.1.18
+-- acpmAvgVoltageVLowValue .2.12.12.2.1.19
+-- acpmAvgVoltageVLowActions .2.12.12.2.1.20
+-- acpmAvgVoltageVLowTrapNum .2.12.12.2.1.21
+-- acpmAvgVoltageVLowClass .2.12.12.2.1.22
+-- acpmAvgVoltageSysrepEnable .2.12.12.2.1.23
+-- acpmAvgVoltageSysrepThreshold .2.12.12.2.1.24
+-- acpmAvgVoltageSysrepLimit .2.12.12.2.1.25
+-- acpmAvgCurrentTable .2.12.12.3
+-- acpmAvgCurrentEntry .2.12.12.3.1
+-- acpmAvgCurrentIndex .2.12.12.3.1.1
+-- acpmAvgCurrentEnable .2.12.12.3.1.2
+-- acpmAvgCurrentDeadband .2.12.12.3.1.3
+-- acpmAvgCurrentVHighValue .2.12.12.3.1.4
+-- acpmAvgCurrentVHighActions .2.12.12.3.1.5
+-- acpmAvgCurrentVHighTrapNum .2.12.12.3.1.6
+-- acpmAvgCurrentVHighClass .2.12.12.3.1.7
+-- acpmAvgCurrentHighValue .2.12.12.3.1.8
+-- acpmAvgCurrentHighActions .2.12.12.3.1.9
+-- acpmAvgCurrentHighTrapNum .2.12.12.3.1.10
+-- acpmAvgCurrentHighClass .2.12.12.3.1.11
+-- acpmAvgCurrentNormalActions .2.12.12.3.1.12
+-- acpmAvgCurrentNormalTrapNum .2.12.12.3.1.13
+-- acpmAvgCurrentNormalClass .2.12.12.3.1.14
+-- acpmAvgCurrentLowValue .2.12.12.3.1.15
+-- acpmAvgCurrentLowActions .2.12.12.3.1.16
+-- acpmAvgCurrentLowTrapNum .2.12.12.3.1.17
+-- acpmAvgCurrentLowClass .2.12.12.3.1.18
+-- acpmAvgCurrentVLowValue .2.12.12.3.1.19
+-- acpmAvgCurrentVLowActions .2.12.12.3.1.20
+-- acpmAvgCurrentVLowTrapNum .2.12.12.3.1.21
+-- acpmAvgCurrentVLowClass .2.12.12.3.1.22
+-- acpmAvgCurrentSysrepEnable .2.12.12.3.1.23
+-- acpmAvgCurrentSysrepThreshold .2.12.12.3.1.24
+-- acpmAvgCurrentSysrepLimit .2.12.12.3.1.25
+-- acpmFreqTable .2.12.12.4
+-- acpmFreqEntry .2.12.12.4.1
+-- acpmFreqIndex .2.12.12.4.1.1
+-- acpmFreqEnable .2.12.12.4.1.2
+-- acpmFreqDeadband .2.12.12.4.1.3
+-- acpmFreqVHighValue .2.12.12.4.1.4
+-- acpmFreqVHighActions .2.12.12.4.1.5
+-- acpmFreqVHighTrapNum .2.12.12.4.1.6
+-- acpmFreqVHighClass .2.12.12.4.1.7
+-- acpmFreqHighValue .2.12.12.4.1.8
+-- acpmFreqHighActions .2.12.12.4.1.9
+-- acpmFreqHighTrapNum .2.12.12.4.1.10
+-- acpmFreqHighClass .2.12.12.4.1.11
+-- acpmFreqNormalActions .2.12.12.4.1.12
+-- acpmFreqNormalTrapNum .2.12.12.4.1.13
+-- acpmFreqNormalClass .2.12.12.4.1.14
+-- acpmFreqLowValue .2.12.12.4.1.15
+-- acpmFreqLowActions .2.12.12.4.1.16
+-- acpmFreqLowTrapNum .2.12.12.4.1.17
+-- acpmFreqLowClass .2.12.12.4.1.18
+-- acpmFreqVLowValue .2.12.12.4.1.19
+-- acpmFreqVLowActions .2.12.12.4.1.20
+-- acpmFreqVLowTrapNum .2.12.12.4.1.21
+-- acpmFreqVLowClass .2.12.12.4.1.22
+-- acpmFreqSysrepEnable .2.12.12.4.1.23
+-- acpmFreqSysrepThreshold .2.12.12.4.1.24
+-- acpmFreqSysrepLimit .2.12.12.4.1.25
+-- acpmTotalRealPowerTable .2.12.12.5
+-- acpmTRPEntry .2.12.12.5.1
+-- acpmTRPIndex .2.12.12.5.1.1
+-- acpmTRPEnable .2.12.12.5.1.2
+-- acpmTRPDeadband .2.12.12.5.1.3
+-- acpmTRPVHighValue .2.12.12.5.1.4
+-- acpmTRPVHighActions .2.12.12.5.1.5
+-- acpmTRPVHighTrapNum .2.12.12.5.1.6
+-- acpmTRPVHighClass .2.12.12.5.1.7
+-- acpmTRPHighValue .2.12.12.5.1.8
+-- acpmTRPHighActions .2.12.12.5.1.9
+-- acpmTRPHighTrapNum .2.12.12.5.1.10
+-- acpmTRPHighClass .2.12.12.5.1.11
+-- acpmTRPNormalActions .2.12.12.5.1.12
+-- acpmTRPNormalTrapNum .2.12.12.5.1.13
+-- acpmTRPNormalClass .2.12.12.5.1.14
+-- acpmTRPLowValue .2.12.12.5.1.15
+-- acpmTRPLowActions .2.12.12.5.1.16
+-- acpmTRPLowTrapNum .2.12.12.5.1.17
+-- acpmTRPLowClass .2.12.12.5.1.18
+-- acpmTRPVLowValue .2.12.12.5.1.19
+-- acpmTRPVLowActions .2.12.12.5.1.20
+-- acpmTRPVLowTrapNum .2.12.12.5.1.21
+-- acpmTRPVLowClass .2.12.12.5.1.22
+-- acpmTRPSysrepEnable .2.12.12.5.1.23
+-- acpmTRPSysrepThreshold .2.12.12.5.1.24
+-- acpmTRPSysrepLimit .2.12.12.5.1.25
+-- acpmDisconnectTable .2.12.12.6
+-- acpmDisconnectEntry .2.12.12.6.1
+-- acpmDisconnectIndex .2.12.12.6.1.1
+-- acpmDisconnectEnable .2.12.12.6.1.2
+-- acpmDisconnectActions .2.12.12.6.1.3
+-- acpmDisconnectTrapNum .2.12.12.6.1.4
+-- acpmDisconnectClass .2.12.12.6.1.5
+-- acpmDisconnectNormalActions .2.12.12.6.1.6
+-- acpmDisconnectNormalTrapNum .2.12.12.6.1.7
+-- acpmDisconnectNormalClass .2.12.12.6.1.8
+-- acpmTotalPowerFactorTable .2.12.12.7
+-- acpmTPFEntry .2.12.12.7.1
+-- acpmTPFIndex .2.12.12.7.1.1
+-- acpmTPFEnable .2.12.12.7.1.2
+-- acpmTPFDeadband .2.12.12.7.1.3
+-- acpmTPFNormalActions .2.12.12.7.1.4
+-- acpmTPFNormalTrapNum .2.12.12.7.1.5
+-- acpmTPFNormalClass .2.12.12.7.1.6
+-- acpmTPFLowValue .2.12.12.7.1.7
+-- acpmTPFLowActions .2.12.12.7.1.8
+-- acpmTPFLowTrapNum .2.12.12.7.1.9
+-- acpmTPFLowClass .2.12.12.7.1.10
+-- acpmTPFVLowValue .2.12.12.7.1.11
+-- acpmTPFVLowActions .2.12.12.7.1.12
+-- acpmTPFVLowTrapNum .2.12.12.7.1.13
+-- acpmTPFVLowClass .2.12.12.7.1.14
+-- acpmTPFSysrepEnable .2.12.12.7.1.15
+-- acpmTPFSysrepThreshold .2.12.12.7.1.16
+-- acpmTPFSysrepLimit .2.12.12.7.1.17
+-- evReset .2.12.16
+-- evResetEnable .2.12.16.1
+-- evResetDelay .2.12.16.2
+-- evResetActions .2.12.16.3
+-- evResetMessage .2.12.16.4
+-- evResetTrapnum .2.12.16.5
+-- evResetClass .2.12.16.6
+-- action .2.14
+-- actionCallNumberTable .2.14.1
+-- actionCallNumberEntry .2.14.1.1
+-- actionCallNumberIndex .2.14.1.1.1
+-- actionCallNumber .2.14.1.1.2
+-- actionPagerTable .2.14.2
+-- actionPagerEntry .2.14.2.1
+-- actionPagerIndex .2.14.2.1.1
+-- actionPagerType .2.14.2.1.2
+-- actionPagerNumber .2.14.2.1.3
+-- actionPagerID .2.14.2.1.4
+-- actionPagerMessage .2.14.2.1.5
+-- actionPagerPostCalloutDelay .2.14.2.1.6
+-- actionPagerPostIDDelay .2.14.2.1.7
+-- actionSched .2.14.3
+-- actionSchedEnable .2.14.3.1
+-- actionSchedBegin .2.14.3.2
+-- actionSchedEnd .2.14.3.3
+-- actionSchedWeekdaysOnly .2.14.3.4
+-- actionAsentria .2.14.4
+-- actionAsentriaRequireAck .2.14.4.1
+-- actionAsentriaVersion .2.14.4.2
+-- actionAsentriaTCPPort .2.14.4.3
+-- actionHostTable .2.14.6
+-- actionHostEntry .2.14.6.1
+-- actionHostIndex .2.14.6.1.1
+-- actionHost .2.14.6.1.2
+-- actionEmailTable .2.14.7
+-- actionEmailEntry .2.14.7.1
+-- actionEmailIndex .2.14.7.1.1
+-- actionEmail .2.14.7.1.2
+-- actionParseError .2.14.8
+-- sys .2.16
+-- sysTime .2.16.1
+-- sysTimeAutoDST .2.16.1.1
+-- sysTimeGMTOffset .2.16.1.2
+-- sysTimeGMTDirection .2.16.1.3
+-- sysTimeNet .2.16.1.4
+-- sysTimeNetEnable .2.16.1.4.1
+-- sysTimeNetHostTable .2.16.1.4.2
+-- sysTimeNetHostEntry .2.16.1.4.2.1
+-- sysTimeNetHostIndex .2.16.1.4.2.1.1
+-- sysTimeNetHost .2.16.1.4.2.1.2
+-- sysPT .2.16.2
+-- sysPTTimeout .2.16.2.1
+-- sysPTEndPause .2.16.2.2
+-- sysPTJoinable .2.16.2.3
+-- sysMTU .2.16.3
+-- sysAnswerString .2.16.4
+-- sysEventFileID .2.16.6
+-- sysEscapeCharacter .2.16.7
+-- sysTimeStamp .2.16.8
+-- sysTimeStampTimeFormat .2.16.8.1
+-- sysTimeStampDateFormat .2.16.8.2
+-- sysTimeStampSpaceAfter .2.16.8.3
+-- sysLog .2.16.9
+-- sysLogMode .2.16.9.1
+-- sysLoghost .2.16.9.2
+-- sysLogFilter .2.16.9.3
+-- sysLogFileSize .2.16.9.4
+-- sysLogFileCount .2.16.9.5
+-- sysLogListenPort .2.16.9.6
+-- sysCRDB .2.16.10
+-- sysCRDBCapacity .2.16.10.1
+-- sysCRDBPercentFull .2.16.10.2
+-- sysCRDBFileIDTable .2.16.10.3
+-- sysCRDBFileIDEntry .2.16.10.3.1
+-- sysCRDBFileIDIndex .2.16.10.3.1.1
+-- sysCRDBFileID .2.16.10.3.1.2
+-- sysCRDBFileEnforceMinTable .2.16.10.4
+-- sysCRDBFileEnforceMinEntry .2.16.10.4.1
+-- sysCRDBFileEnforceMinIndex .2.16.10.4.1.1
+-- sysCRDBFileEnforceMin .2.16.10.4.1.2
+-- sysCharMask .2.16.11
+-- sysPrompt .2.16.12
+-- sysBootStatus .2.16.13
+-- sysLoc .2.16.14
+-- sysLocLatitude .2.16.14.1
+-- sysLocLongitude .2.16.14.2
+-- sysLocXOffset .2.16.14.3
+-- sysLocYOffset .2.16.14.4
+-- sysLocAngle .2.16.14.5
+-- sysLocAltitude .2.16.14.6
+-- sysAssetMgmt .2.16.15
+-- sysAMManufacturer .2.16.15.1
+-- sysAMProduct .2.16.15.2
+-- sysAMSerialNumber .2.16.15.3
+-- sysAMHardwareOptions .2.16.15.4
+-- sysAMSoftwareVersion .2.16.15.5
+-- sysAMSiteName .2.16.15.6
+-- sysFileTransfer .2.16.17
+-- sysFileTransferStatus .2.16.17.1
+-- sysFileTransferURL .2.16.17.2
+-- sysFileTransferUsername .2.16.17.3
+-- sysFileTransferPassword .2.16.17.4
+-- sysUpdate .2.16.18
+-- sysUpdateStatus .2.16.18.1
+-- auditLog .2.17
+-- auditLogEnable .2.17.1
+-- auditLogStoreResets .2.17.2
+-- auditLogStoreCommands .2.17.3
+-- auditLogStoreOutputs .2.17.4
+-- auditLogStoreAlarmActions .2.17.5
+-- auditLogStorePwdFailures .2.17.6
+-- auditLogStoreLogins .2.17.7
+-- auditLogStoreSHSK .2.17.8
+-- auditLogStorePassthrough .2.17.9
+-- auditLogStoreInactivity .2.17.10
+-- auditLogStorePolling .2.17.11
+-- auditLogMaxSize .2.17.12
+-- scripting .2.18
+-- scrGlobalEnable .2.18.1
+-- scrDTRCtrlPortEnableTable .2.18.2
+-- scrDTRCtrlPortEnableEnabletry .2.18.2.1
+-- scrDTRCtrlPortEnableIndex .2.18.2.1.1
+-- scrDTRCtrlPortEnable .2.18.2.1.2
+-- scrTable .2.18.3
+-- scrEntry .2.18.3.1
+-- scrIndex .2.18.3.1.1
+-- scrEnable .2.18.3.1.2
+-- scrName .2.18.3.1.3
+-- scrFilename .2.18.3.1.4
+-- scrRunAlways .2.18.3.1.5
+-- scrRunAtStartup .2.18.3.1.6
+-- scrRunScheduled .2.18.3.1.7
+-- scrScheduleTime .2.18.3.1.8
+-- scrArguments .2.18.3.1.9
+-- scrRepeatInterval .2.18.3.1.10
+-- scrVolatileStringTable .2.18.4
+-- scrVolatileStringEntry .2.18.4.1
+-- scrVolatileStringIndex .2.18.4.1.1
+-- scrVolatileString .2.18.4.1.2
+-- scrVolatileIntTable .2.18.5
+-- scrVolatileIntEntry .2.18.5.1
+-- scrVolatileIntIndex .2.18.5.1.1
+-- scrVolatileInt .2.18.5.1.2
+-- scrNonVolatileStringTable .2.18.6
+-- scrNonVolatileStringEntry .2.18.6.1
+-- scrNonVolatileStringIndex .2.18.6.1.1
+-- scrNonVolatileString .2.18.6.1.2
+-- scrNonVolatileIntTable .2.18.7
+-- scrNonVolatileIntEntry .2.18.7.1
+-- scrNonVolatileIntIndex .2.18.7.1.1
+-- scrNonVolatileInt .2.18.7.1.2
+
+-- productIds .3
+-- siteName 3.1
+-- thisProduct .3.2
+-- stockTrapString .3.3
+-- trapEventTypeNumber .3.4
+-- trapEventTypeName .3.5
+-- trapIncludedValue .3.6
+-- trapIncludedString .3.7
+-- trapTypeString .3.8
+-- trapEventClassNumber .3.9
+-- trapEventClassName .3.10
+
+-- keyInterface .4.0
+
+
+--***************************************************************************************
+--TOP-LEVEL OBJECT IDENTIFIERS
+--***************************************************************************************
+
+
+
+ status OBJECT IDENTIFIER ::= { s571 1 }
+ --1.3.6.1.4.1.3052.14.1
+
+ eventSensorStatus OBJECT IDENTIFIER ::= { status 1 }
+ --1.3.6.1.4.1.3052.14.1.1
+
+ dataEventStatus OBJECT IDENTIFIER ::= { status 2 }
+ --1.3.6.1.4.1.3052.14.1.2
+
+ powerDistributionStatus OBJECT IDENTIFIER ::= { status 5 }
+ --1.3.6.1.4.1.3052.14.1.5
+
+ pdMain OBJECT IDENTIFIER ::= { powerDistributionStatus 2 }
+ --1.3.6.1.4.1.3052.14.1.5.2
+
+ pdMainCurrent OBJECT IDENTIFIER ::= { pdMain 1 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1
+
+ pdMainVoltage OBJECT IDENTIFIER ::= { pdMain 2 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2
+
+ pdMainPower OBJECT IDENTIFIER ::= { pdMain 3 }
+ --1.3.6.1.4.1.3052.14.1.5.2.3
+
+ pdOutput OBJECT IDENTIFIER ::= { powerDistributionStatus 3 }
+ --1.3.6.1.4.1.3052.14.1.5.3
+
+ pdOutputCurrent OBJECT IDENTIFIER ::= { pdOutput 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1
+
+ pdOutputFuse OBJECT IDENTIFIER ::= { pdOutput 4 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4
+
+ pdNextGen OBJECT IDENTIFIER ::= { powerDistributionStatus 4 }
+ --1.3.6.1.4.1.3052.14.1.5.4
+
+ pdSystem OBJECT IDENTIFIER ::= { powerDistributionStatus 5 }
+ --1.3.6.1.4.1.3052.14.1.5.5
+
+ fuelSensorStatus OBJECT IDENTIFIER ::= { status 6 }
+ --1.3.6.1.4.1.3052.14.1.6
+
+ wirelessModemStatus OBJECT IDENTIFIER ::= { status 7 }
+ --1.3.6.1.4.1.3052.14.1.7
+
+ acPowerMonitorStatus OBJECT IDENTIFIER ::= { status 8 }
+ --1.3.6.1.4.1.3052.14.1.8
+
+ aisgStatus OBJECT IDENTIFIER ::= { status 9 }
+ --1.3.6.1.4.1.3052.14.1.9
+
+
+ config OBJECT IDENTIFIER ::= { s571 2 }
+ --1.3.6.1.4.1.3052.14.2
+
+ eventSensorBasics OBJECT IDENTIFIER ::= { config 1 }
+ --1.3.6.1.4.1.3052.14.2.1
+
+ eventSensorPointConfig OBJECT IDENTIFIER ::= { config 2 }
+ --1.3.6.1.4.1.3052.14.2.2
+
+ serialPorts OBJECT IDENTIFIER ::= { config 3 }
+ --1.3.6.1.4.1.3052.14.2.3
+
+ network OBJECT IDENTIFIER ::= { config 4 }
+ --1.3.6.1.4.1.3052.14.2.4
+
+ interface OBJECT IDENTIFIER ::= { network 1 }
+ --1.3.6.1.4.1.3052.14.2.4
+
+ ethernet OBJECT IDENTIFIER ::= { interface 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1
+
+ ethernet1 OBJECT IDENTIFIER ::= { ethernet 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1
+
+ eth1VLAN OBJECT IDENTIFIER ::= { ethernet1 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5
+
+ eth1VLAN1 OBJECT IDENTIFIER ::= { eth1VLAN 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.1
+
+ eth1VLAN2 OBJECT IDENTIFIER ::= { eth1VLAN 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.2
+
+ eth1VLAN3 OBJECT IDENTIFIER ::= { eth1VLAN 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.3
+
+ eth1VLAN4 OBJECT IDENTIFIER ::= { eth1VLAN 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.4
+
+ eth1VLAN5 OBJECT IDENTIFIER ::= { eth1VLAN 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.5
+
+ eth1VLAN6 OBJECT IDENTIFIER ::= { eth1VLAN 6 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.5.6
+
+ eth1IPv6 OBJECT IDENTIFIER ::= { ethernet1 7 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.7
+
+ eth1IPv6Static OBJECT IDENTIFIER ::= { eth1IPv6 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.7.2
+
+ eth1IPv6Auto OBJECT IDENTIFIER ::= { eth1IPv6 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.7.3
+
+ ethernet2 OBJECT IDENTIFIER ::= { ethernet 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2
+
+ eth2VLAN OBJECT IDENTIFIER ::= { ethernet2 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5
+
+ eth2VLAN1 OBJECT IDENTIFIER ::= { eth2VLAN 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.1
+
+ eth2VLAN2 OBJECT IDENTIFIER ::= { eth2VLAN 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.2
+
+ eth2VLAN3 OBJECT IDENTIFIER ::= { eth2VLAN 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.3
+
+ eth2VLAN4 OBJECT IDENTIFIER ::= { eth2VLAN 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.4
+
+ eth2VLAN5 OBJECT IDENTIFIER ::= { eth2VLAN 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.5
+
+ eth2VLAN6 OBJECT IDENTIFIER ::= { eth2VLAN 6 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.5.6
+
+ eth2IPv6 OBJECT IDENTIFIER ::= { ethernet2 7 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.7
+
+ eth2IPv6Static OBJECT IDENTIFIER ::= { eth2IPv6 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.7.2
+
+ eth2IPv6Auto OBJECT IDENTIFIER ::= { eth2IPv6 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.2.7.3
+
+ snmp OBJECT IDENTIFIER ::= { network 8 }
+ --1.3.6.1.4.1.3052.14.2.4.8
+
+ snmpNotificationTx OBJECT IDENTIFIER ::= { snmp 7 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7
+
+ snmpPoll OBJECT IDENTIFIER ::= { snmp 9 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9
+
+ ftpPush OBJECT IDENTIFIER ::= { network 9 }
+ --1.3.6.1.4.1.3052.14.2.4.9
+
+ ppp OBJECT IDENTIFIER ::= { network 10 }
+ --1.3.6.1.4.1.3052.14.2.4.10
+
+ pppDial OBJECT IDENTIFIER ::= { ppp 1 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1
+
+ pppHost OBJECT IDENTIFIER ::= { ppp 2 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2
+
+ routing OBJECT IDENTIFIER ::= { network 11 }
+ --1.3.6.1.4.1.3052.14.2.4.11
+
+ netSecurity OBJECT IDENTIFIER ::= { network 12 }
+ --1.3.6.1.4.1.3052.14.2.4.12
+
+ ipRestriction OBJECT IDENTIFIER ::= { netSecurity 1 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1
+
+ rts OBJECT IDENTIFIER ::= { network 13 }
+ --1.3.6.1.4.1.3052.14.2.4.13
+
+ rtsAlarms OBJECT IDENTIFIER ::= { rts 2 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2
+
+ trap OBJECT IDENTIFIER ::= { network 14 }
+ --1.3.6.1.4.1.3052.14.2.4.14
+
+ trapInclude OBJECT IDENTIFIER ::= { trap 1}
+ --1.3.6.1.4.1.3052.14.2.4.14.1
+
+ routeTest OBJECT IDENTIFIER ::= { network 15 }
+ --1.3.6.1.4.1.3052.14.2.4.15
+
+ wireless OBJECT IDENTIFIER ::= { network 16 }
+ --1.3.6.1.4.1.3052.14.2.4.16
+
+ wirelessConnectivity OBJECT IDENTIFIER ::= { wireless 20 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20
+
+ email OBJECT IDENTIFIER ::= { network 17 }
+ --1.3.6.1.4.1.3052.14.2.4.17
+
+ netAdvanced OBJECT IDENTIFIER ::= { network 18 }
+ --1.3.6.1.4.1.3052.14.2.4.18
+
+ web OBJECT IDENTIFIER ::= { network 19 }
+ --1.3.6.1.4.1.3052.14.2.4.19
+
+ ipv6 OBJECT IDENTIFIER ::= { network 21 }
+ --1.3.6.1.4.1.3052.14.2.4.21
+
+ cpe OBJECT IDENTIFIER ::= { network 22 }
+ --1.3.6.1.4.1.3052.14.2.4.22
+
+ modem OBJECT IDENTIFIER ::= { config 5 }
+ --1.3.6.1.4.1.3052.14.2.5
+
+ modemClid OBJECT IDENTIFIER ::= { modem 8 }
+ --1.3.6.1.4.1.3052.14.2.5.7
+
+ time OBJECT IDENTIFIER ::= { config 8 }
+ --1.3.6.1.4.1.3052.14.2.8
+
+ console OBJECT IDENTIFIER ::= { config 10 }
+ --1.3.6.1.4.1.3052.14.2.10
+
+ unitSecurity OBJECT IDENTIFIER ::= { config 11 }
+ --1.3.6.1.4.1.3052.14.2.11
+
+ secCore OBJECT IDENTIFIER ::= { unitSecurity 1 }
+ --1.3.6.1.4.1.3052.14.2.11.1
+
+ secFactory OBJECT IDENTIFIER ::= { unitSecurity 3 }
+ --1.3.6.1.4.1.3052.14.2.11.3
+
+ secSSH OBJECT IDENTIFIER ::= { unitSecurity 4 }
+ --1.3.6.1.4.1.3052.14.2.11.4
+
+ secVPN OBJECT IDENTIFIER ::= { unitSecurity 5 }
+ --1.3.6.1.4.1.3052.14.2.11.5
+
+ event OBJECT IDENTIFIER ::= { config 12 }
+ --1.3.6.1.4.1.3052.14.2.12
+
+ evCore OBJECT IDENTIFIER ::= { event 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evLog OBJECT IDENTIFIER ::= { evCore 3 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3
+
+ evMgmt OBJECT IDENTIFIER ::= { evCore 4 }
+ --1.3.6.1.4.1.3052.14.2.12.1.4
+
+ evData OBJECT IDENTIFIER ::= { event 2 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evdCore OBJECT IDENTIFIER ::= { evData 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.1
+
+ evNoData1 OBJECT IDENTIFIER ::= { event 3 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evNoData2 OBJECT IDENTIFIER ::= { event 4 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evSched1 OBJECT IDENTIFIER ::= { event 5 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evSched2 OBJECT IDENTIFIER ::= { event 6 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ evNoSensor OBJECT IDENTIFIER ::= { event 9 }
+ --1.3.6.1.4.1.3052.14.2.12.1
+
+ fuelSensor OBJECT IDENTIFIER ::= { event 11 }
+ --1.3.6.1.4.1.3052.14.2.12.11
+
+ acPowerMonitor OBJECT IDENTIFIER ::= { event 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12
+
+ evReset OBJECT IDENTIFIER ::= { event 16 }
+ --1.3.6.1.4.1.3052.14.2.12.16
+
+ action OBJECT IDENTIFIER ::= { config 14 }
+ --1.3.6.1.4.1.3052.14.2.14
+
+ actionSched OBJECT IDENTIFIER ::= { action 3 }
+ --1.3.6.1.4.1.3052.14.2.14.3
+
+ actionAsentria OBJECT IDENTIFIER ::= { action 4 }
+ --1.3.6.1.4.1.3052.14.2.14.4
+
+ sys OBJECT IDENTIFIER ::= { config 16 }
+ --1.3.6.1.4.1.3052.14.2.16
+
+ sysTime OBJECT IDENTIFIER ::= { sys 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1
+
+ sysTimeNet OBJECT IDENTIFIER ::= { sysTime 4 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4
+
+ sysPT OBJECT IDENTIFIER ::= { sys 2 }
+ --1.3.6.1.4.1.3052.14.2.16.2
+
+ sysTimeStamp OBJECT IDENTIFIER ::= { sys 8 }
+ --1.3.6.1.4.1.3052.14.2.16.8
+
+ sysLog OBJECT IDENTIFIER ::= { sys 9 }
+ --1.3.6.1.4.1.3052.14.2.16.9
+
+ sysCRDB OBJECT IDENTIFIER ::= { sys 10 }
+ --1.3.6.1.4.1.3052.14.2.16.10
+
+ sysLoc OBJECT IDENTIFIER ::= { sys 14 }
+ --1.3.6.1.4.1.3052.14.2.16.14
+
+ sysAssetMgmt OBJECT IDENTIFIER ::= { sys 15 }
+ --1.3.6.1.4.1.3052.14.2.16.15
+
+ sysFileTransfer OBJECT IDENTIFIER ::= { sys 17 }
+ --1.3.6.1.4.1.3052.14.2.16.17
+
+ sysUpdate OBJECT IDENTIFIER ::= { sys 18 }
+ --1.3.6.1.4.1.3052.14.2.16.18
+
+ auditLog OBJECT IDENTIFIER ::= { config 17 }
+ --1.3.6.1.4.1.3052.14.2.17
+
+ scripting OBJECT IDENTIFIER ::= { config 18 }
+ --1.3.6.1.4.1.3052.14.2.18
+
+ productIds OBJECT IDENTIFIER ::= { s571 3 }
+ --1.3.6.1.4.1.3052.14.3
+
+--***************************************************************************************
+--OBJECT DEFINITIONS
+--***************************************************************************************
+
+--***************************************************************************************
+--EventSensor Status Section 1.1
+--***************************************************************************************
+
+esPointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "
+ This table organizes 4 basic attributes of points. A point
+ is a particular sensor on an EventSensor (e.g., temperature,
+ humidity, contact closure 2, output 5, etc.). The 4 point
+ attributes are its name, whether it's in its event state,
+ the point's value as a number and its value as a string.
+
+ Points are referenced by a point index. The point index
+ is a string of 3 numbers separated by periods.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor; namely, which EventSensor,
+ point class, and which-sensor-of-that-class (a.k.a. point).
+ "
+ ::= { eventSensorStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.1.1
+
+esPointEntry OBJECT-TYPE
+ SYNTAX ESPoint
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point table"
+ INDEX { esIndexES, esIndexPC, esIndexPoint }
+ ::= { esPointTable 1 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1
+
+esIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point index is a string of 3 numbers separated
+ by periods. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor; namely, which EventSensor, point class,
+ and which-sensor-of-that-class (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndexES=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esPointEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.1
+
+esIndexPC OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to point class.
+
+ The point index is a string of 3 numbers separated by periods.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor; namely, which EventSensor,
+ point class, and which-sensor-of-that-class (a.k.a. point).
+
+ The values for this object are:
+ 1=temperature sensor
+ 2=contact closure
+ 3=humidity sensor
+ 4=noise sensor
+ 5=analog input
+ 6=output (relay output or power output)
+ "
+ ::= { esPointEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.2
+
+esIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with esIndexPC (Point Class or type)
+ and esIndexES (which EventSensor) uniquely defines each
+ point (sensor or output) attached to a unit. For
+ example, if esIndexES is 3, esIndexPC is 1 and
+ esIndexPoint is 4 then this is the Fourth Temperature
+ Sensor on EventSensor number 3."
+ ::= { esPointEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.3
+
+esPointName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the point on an EventSensor. For example,
+ 'AC temp' (in the case of the temperature sensor on an
+ EventSensor).
+
+ There can be multiple points of the same point class on an
+ EventSensor (e.g., 8 contact closures) and multiple sensor
+ classes on an EventSensor (e.g., temperature, contact closure,
+ humidity).
+
+ If the point referenced by a given point index is solitary
+ (e.g., temperature sensor, because there can be only one on
+ an EventSensor), then this object reads as '<EventSensor
+ name>'. Setting this object for solitary point indices sets
+ the EventSensor name only.
+
+ On the other hand, if a given point is among other points of
+ the same point class on an EventSensor, then this object reads
+ as '<Sensor name>'. Setting this object for these NON-
+ solitary point indices sets the sensor name only - not the
+ EventSensor name."
+ ::= { esPointEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.4
+
+esPointInEventState OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A number referring to the event state of a point
+ on an EventSensor. This number can have different
+ meanings depending on the point class.
+
+ If the point class is temperature, humidity, or
+ analog input, then the values of this object are:
+ 1=very low
+ 2=low
+ 3=normal
+ 4=high
+ 5=very high
+
+ For contact closures the values of this object are:
+ 1=point in event state
+ 2=point in normal state
+
+ For outputs the values of this object is the numeric
+ code for the logical state of the output: 1 or 2. The
+ logical state of the output is either active/inactive for
+ relay outputs or on/off for power outputs. The logical
+ state of the output has different nomenclature depending
+ on the type of the output (relay output or power output):
+
+ 1=active (for relay output) or on (for power output)
+ 2=inactive (for relay output) or off (for power output)
+
+ This is not necessarily representative of physical state
+ of the output. Physical state is energized/de-energized,
+ for both relay and power outputs. For relay outputs,
+ the active logical state corresponds to either the energized
+ physical state or the de-energized physical state depending
+ on how the relay output is configured. For power outputs,
+ the on logical state always corresponds to the energized
+ physical state.
+
+ For any point class and any point, if the event
+ state is undefined, then the value of this object
+ is 0.
+
+ For any point class except output, this object is read-only.
+ For outputs, setting this object to 1 puts the output into
+ its active logical state.
+
+ Setting this object to 2 puts the output into its inactive
+ logical state.
+
+ Setting this object to any value greater than 2 puts the
+ output into its active logical state for that many seconds
+ (up to 3600), after which time it puts the output into its
+ inactive logical state.
+ "
+ ::= { esPointEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.5
+
+esPointValueInt OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A read-only number referring to the value of a
+ point on an EventSensor.
+
+ If the point class is temperature, then this object
+ is the temperature in its configured scale (default
+ is Fahrenheit).
+
+ If the point class is contact closure, then
+ this object is either 0 (open) or 1 (closed).
+
+ If the point class is humidity, then this object
+ is the percent relative humidity.
+
+ If the point class is analog input, then this
+ object is the signed input value in tenths of the
+ configured units.
+
+ If the point class is an output, then this object is
+ the numeric code for the physical state of the output.
+ 0=de-energized
+ 1=energized
+
+ This object cannot be used to control the output, i.e,
+ change its logical or physical state (instead use
+ the esPointInEventState object).
+ "
+ ::= { esPointEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.6
+
+esPointValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string referring to the value of a point on an
+ EventSensor.
+
+ For contact closures this object is either 'Open'
+ or 'Closed'.
+
+ For outputs this object is a concatenation of the
+ logical state and physical state, separated by '/'.
+
+ For a relay output this object can be one of the
+ following 4 possible values:
+
+ Active/Energized
+ Inactive/Energized
+ Active/De-energized
+ Inactve/De-energized
+
+ For a power output this object can be one of the
+ following 2 possible values:
+
+ On/Energized
+ Off/De-energized
+
+ For temperature and humidity point classes, this
+ object is the string representation of the
+ esPointValueInt object. For temperature, 'C' or
+ 'F' is including in the string to indicate scale.
+
+ For analog inputs, this object is the string
+ representation of the plus/minus input in the
+ configured units appended with the unit name.
+ "
+ ::= { esPointEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.7
+
+esPointTimeLastChange OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last time an event was
+ triggerred for a point on an EventSensor in
+ MM/DD/YY HH:MM:SS format.
+
+ For contact closures, the possible events are
+ Active and Inactive. For temperature, humidity,
+ and analog inputs, the possible events are Normal,
+ High, Very High, Low, and Very Low.
+
+ For outputs, this object is a null string."
+ ::= { esPointEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.8
+
+esPointTimetickLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time of the last time an event was
+ triggerred for a point on an EventSensor in
+ 100ths of seconds since reset.
+
+ For contact closures, the possible events are
+ Active and Inactive. For temperature, humidity,
+ and analog inputs, the possible events are Normal,
+ High, Very High, Low, and Very Low.
+
+ For outputs, this object is 0."
+ ::= { esPointEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.1.1.1.9
+
+--***************************************************************************************
+--Data Event Status Section 1.2
+--***************************************************************************************
+
+deStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DEStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Data Event Status Table"
+ ::= { dataEventStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.2.1
+
+deStatusEntry OBJECT-TYPE
+ SYNTAX DEStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "EventSensor status entry"
+ INDEX { deStatusIndex }
+ ::= { deStatusTable 1 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1
+
+deStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for Data Events"
+ ::= { deStatusEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1.1
+
+deStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Data Event name"
+ ::= { deStatusEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1.2
+
+deStatusCounter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times a data record has matched this
+ event's equation.
+ Range: 1-999999999"
+ ::= { deStatusEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1.3
+
+deStatusThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times the equation is matched before
+ an event is triggered.
+ Range: 1-999999999"
+ ::= { deStatusEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.2.1.1.4
+
+modemStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status of modem (idle, dialing, connected, etc.)"
+ ::= { status 3 }
+ --1.3.6.1.4.1.3052.14.1.3
+
+modemCLIDLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ModemCLIDLogConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of numbers of recent dialing parties"
+ ::= { status 4 }
+ --1.3.6.1.4.1.3052.14.1.4
+
+modemCLIDLogEntry OBJECT-TYPE
+ SYNTAX ModemCLIDLogConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CLID log entries"
+ INDEX { modemCLIDLogIndex }
+ ::= { modemCLIDLogTable 1 }
+ --1.3.6.1.4.1.3052.14.1.4.1
+
+modemCLIDLogIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CLID log entries"
+ ::= { modemCLIDLogEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.4.1.1
+
+modemCLIDLogNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "recently logged number of dialing party"
+ ::= { modemCLIDLogEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.4.1.2
+
+--***************************************************************************************
+--Power Distribution Status Section 1.5
+--***************************************************************************************
+
+pdConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution output configuration"
+ ::= { powerDistributionStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.5.1
+
+pdMainCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current event state"
+ ::= { pdMainCurrent 2 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.2
+
+pdMainCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current value in mA"
+ ::= { pdMainCurrent 3 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.3
+
+pdMainCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current value formatted as a string"
+ ::= { pdMainCurrent 4 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.4
+
+pdMainCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor deadband in mA"
+ ::= { pdMainCurrent 10 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.10
+
+pdMainCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor very high threshold in mA"
+ ::= { pdMainCurrent 11 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.11
+
+pdMainCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor high threshold in mA"
+ ::= { pdMainCurrent 12 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.12
+
+pdMainCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor low threshold in mA"
+ ::= { pdMainCurrent 13 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.13
+
+pdMainCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main current sensor very low threshold in mA"
+ ::= { pdMainCurrent 14 }
+ --1.3.6.1.4.1.3052.14.1.5.2.1.14
+
+pdMainVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage event state"
+ ::= { pdMainVoltage 2 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.2
+
+pdMainVoltageValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage value in mV"
+ ::= { pdMainVoltage 3 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.3
+
+pdMainVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage value formatted as a string"
+ ::= { pdMainVoltage 4 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.4
+
+pdMainVoltageDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor deadband in mV"
+ ::= { pdMainVoltage 10 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.10
+
+pdMainVoltageVHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor very high threshold in mV"
+ ::= { pdMainVoltage 11 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.11
+
+pdMainVoltageHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor high threshold in mV"
+ ::= { pdMainVoltage 12 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.12
+
+pdMainVoltageLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor low threshold in mV"
+ ::= { pdMainVoltage 13 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.13
+
+pdMainVoltageVLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main voltage sensor very low threshold in mV"
+ ::= { pdMainVoltage 14 }
+ --1.3.6.1.4.1.3052.14.1.5.2.2.14
+
+pdMainPowerValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main power value in Watts"
+ ::= { pdMainPower 3 }
+ --1.3.6.1.4.1.3052.14.1.5.2.3.3
+
+pdMainPowerValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power Distribution main power value formatted as a string"
+ ::= { pdMainPower 4 }
+ --1.3.6.1.4.1.3052.14.1.5.2.3.4
+
+pdOutputCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerDistribOutputCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of power output current values"
+ ::= { pdOutput 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1
+
+pdOutputCurrentEntry OBJECT-TYPE
+ SYNTAX PowerDistribOutputCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of output current values"
+ INDEX { pdOutputCurrentIndex }
+ ::= { pdOutputCurrentTable 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1
+
+pdOutputCurrentIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..13)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power output current values"
+ ::= { pdOutputCurrentEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.1
+
+pdOutputCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of this power distribution output
+ current (Very Low, Low, Normal, High, Very High)"
+ ::= { pdOutputCurrentEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.2
+
+pdOutputCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output current value in mA"
+ ::= { pdOutputCurrentEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.3
+
+pdOutputCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output current value formatted as a fixed-point string
+ in Amps."
+ ::= { pdOutputCurrentEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.4
+
+pdOutputCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this power output current sensor"
+ ::= { pdOutputCurrentEntry 10 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.10
+
+pdOutputCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high threshold for this power output current sensor"
+ ::= { pdOutputCurrentEntry 11 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.11
+
+pdOutputCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High threshold for this power output current sensor"
+ ::= { pdOutputCurrentEntry 12 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.12
+
+pdOutputCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low threshold for this power output current sensor"
+ ::= { pdOutputCurrentEntry 13 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.13
+
+pdOutputCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold for this power output current sensor"
+ ::= { pdOutputCurrentEntry 14 }
+ --1.3.6.1.4.1.3052.14.1.5.3.1.1.14
+
+pdOutputFuseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerDistribOutputFuse
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of output fuse values"
+ ::= { pdOutput 4 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4
+
+pdOutputFuseEntry OBJECT-TYPE
+ SYNTAX PowerDistribOutputFuse
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of output fuse values"
+ INDEX { pdOutputFuseIndex }
+ ::= { pdOutputFuseTable 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4.1
+
+pdOutputFuseIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..13)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of output fuse values"
+ ::= { pdOutputFuseEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4.1.1
+
+pdOutputFuseInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A number referring to the event state of a power
+ distribution output fuse.
+
+ 14=fuse blown
+ 15=fuse ok"
+ ::= { pdOutputFuseEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4.1.2
+
+pdOutputFuseValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output fuse value formatted as a string. E.g.,
+ 'BLOWN' or 'OK'"
+ ::= { pdOutputFuseEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.5.3.4.1.4
+
+pdnTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PowerDistribNextGen
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of power distribution objects arranged according
+ to next-generation methodology (i.e., using multiple PowerBoss
+ power distributors in addition to the on-board power
+ distributor)."
+ ::= { pdNextGen 1 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1
+
+pdnEntry OBJECT-TYPE
+ SYNTAX PowerDistribNextGen
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of power distribution objects arranged according
+ to next-generation methodology (i.e., using multiple PowerBoss
+ power distributors in addition to the on-board power
+ distributor)."
+ INDEX { pdnIndexPD, pdnIndexOutput }
+ ::= { pdnTable 1 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1
+
+pdnIndexPD OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power distribution objects, specifically the
+ index that refers to which power distributor. A value of 200 means
+ the internal power distributor. A value from 1 to 16 refers to a
+ PowerBoss external power distributor, and is the same value as esIndexES,
+ which refers to the PowerBoss as an EventSensor in the eventSensorStatus
+ object table. In other words, pdnIndexPD is the same as esIndexES:
+ esIndexES is used to refer to the PowerBoss as an eventsensor (i.e., control
+ outputs), while pdnIndexPD is used to refer to the PowerBoss when used for
+ power distribution monitoring (i.e., to alarm on output
+ current/voltage/fuse status)."
+ ::= { pdnEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.1
+
+pdnIndexOutput OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of power distribution objects, specifically the
+ index that refers to which output on the power distributor specified
+ by pdnIndexPD. For objects where the output is irrelevant, this index
+ should be 1."
+ ::= { pdnEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.2
+
+pdnConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs on the power distributor specified by pdnIndexPD.
+ pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.3
+
+pdnMainCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the current (i.e. Amps) event of the power distributor
+ specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
+ Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
+ 'Very High'."
+ ::= { pdnEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.4
+
+pdnMainCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current drawn, in mA, for the power distributor specified by pdnIndexPD.
+ If pdnIndexPD is 200 then this is the internal power distributor and refers to
+ the current drawn by the S571 (which is comprised of the internal power
+ distributor and ancillary internal equipment) and all equipment powered by the
+ S571's internal power outputs. If pdnIndexPD is 1-16 then this is an external
+ power distributor (PowerBoss) and refers to the current drawn by that PowerBoss and all
+ equipment powered by that PowerBoss. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.5
+
+pdnMainCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnMainCurrentValue formatted as a string in units of Amps, with
+ 3 decimal places. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.6
+
+pdnMainCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mA, for the main current sensor for the power distributor
+ specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.7
+
+pdnMainCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Very High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.8
+
+pdnMainCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.9
+
+pdnMainCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 10 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.10
+
+pdnMainCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for the main current sensor's Very Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 11 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.11
+
+pdnMainVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the voltage event of the power distributor
+ specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
+ Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
+ 'Very High'."
+ ::= { pdnEntry 12 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.12
+
+pdnMainVoltageValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, at the power distributor specified by pdnIndexPD.
+ If pdnIndexPD is 200 then this is the internal power distributor and refers to
+ the voltage at the S571 (which is comprised of the internal power
+ distributor and ancillary internal equipment) and all equipment powered by the
+ S571's internal power outputs. If pdnIndexPD is 1-16 then this is an external
+ power distributor (PowerBoss) and refers to the voltage at that PowerBoss and all
+ equipment powered by that PowerBoss. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 13 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.13
+
+pdnMainVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnMainVoltageValue formatted as a string in units of Volts, with
+ 3 decimal places. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 14 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.14
+
+pdnMainVoltageDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mV, for the main voltage sensor for the power distributor
+ specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 15 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.15
+
+pdnMainVoltageVHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mA, for the main voltage sensor's Very High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 16 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.16
+
+pdnMainVoltageHighVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's High event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 17 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.17
+
+pdnMainVoltageLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 18 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.18
+
+pdnMainVoltageVLowVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage, in mV, for the main voltage sensor's Very Low event threshold,
+ for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 19 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.19
+
+pdnMainPowerValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power, in Watts, for the power distributor specified by pdIndexPD.
+ pdnIndexOutput should be 1 for this object."
+ ::= { pdnEntry 20 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.20
+
+pdnMainPowerValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power, in Watts, for the power distributor specified by pdIndexPD,
+ formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1
+ for this object."
+ ::= { pdnEntry 21 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.21
+
+pdnOutputCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the current (i.e. Amps) event of the power distributor
+ output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200
+ and pdnIndexOutput=2, this refers to power output #2 of the internal power
+ distributor. Possible values for this object are: 'Very Low', 'Low', 'Normal',
+ 'High', 'Very High'."
+ ::= { pdnEntry 22 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.22
+
+pdnOutputCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current drawn, in mA, for the power distributor output specified by
+ pdnIndexPD and pdIndexOutput. If pdnIndexPD is 200 then this is the internal
+ power distributor and refers to the current drawn by a specific power output
+ on the S571. If pdIndexPD is 3 then this is an external power distributor (PowerBoss)
+ identified as 'power distributor 3' and refers to the current drawn by a
+ specific power output on that PowerBoss. The specific power output is specified by
+ pdIndexOutput."
+ ::= { pdnEntry 23 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.23
+
+pdnOutputCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Essentially pdnOutputCurrentValue formatted as a string in units of Amps, with
+ 3 decimal places."
+ ::= { pdnEntry 24 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.24
+
+pdnOutputCurrentDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The deadband, in mA, for the main current sensor for the power distributor
+ specified by pdIndexPD. The power output is specified by pdnIndexOutput."
+ ::= { pdnEntry 25 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.25
+
+pdnOutputCurrentVHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Very High
+ event threshold, for the power distributor specified by pdIndexPD. The power
+ output is specified by pdnIndexOutput."
+ ::= { pdnEntry 26 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.26
+
+pdnOutputCurrentHighCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor High event
+ threshold, for the power distributor specified by pdIndexPD. The power output
+ is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 27 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.27
+
+pdnOutputCurrentLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Low event
+ threshold, for the power distributor specified by pdIndexPD. The power output
+ is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 28 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.28
+
+pdnOutputCurrentVLowCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current, in mA, for a specific power output's current sensor Very Low
+ event threshold, for the power distributor specified by pdIndexPD. The power
+ output is specified by pdnIndexOutput for this object."
+ ::= { pdnEntry 29 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.29
+
+pdnOutputFuseInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event state of the fuse event of the power distributor output specified
+ by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2,
+ this refers to power output #2 of the PowerBoss external power distributor,
+ identified as 'power distributor 14'. Possible values for this object are:
+ 'Very Low', 'Low', 'Normal', 'High', 'Very High'. This object exists only for
+ power distributors with fuse monitoring support."
+ ::= { pdnEntry 30 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.30
+
+pdnOutputFuseValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the fuse of the power distributor output specified
+ by pdnIndexPD and pdnIndexOutput. Possible values for this object are:
+ 'BLOWN' and 'OK'. This object exists only for power distributors with
+ fuse monitoring support."
+ ::= { pdnEntry 31 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.31
+
+pdnMainCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValue"
+ ::= { pdnEntry 32 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.32
+
+pdnOutputCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
+ ::= { pdnEntry 33 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.33
+
+pdnOutputCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
+ ::= { pdnEntry 34 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.34
+
+pdnDeviceCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current drawn by device in mA. For the internal power distributor device,
+ this is the current drawn by the SiteBoss 571. For an external power
+ distributor device (PowerBoss), this is the current drawn by the
+ PowerBoss. This object exists only for power distributors with device
+ current monitoring support."
+ ::= { pdnEntry 35 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.35
+
+pdnDeviceCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current drawn by device as a string with units (Amps). For the internal
+ power distributor device, this is the current drawn by the SiteBoss 571.
+ For an external power distributor device (PowerBoss), this is the
+ current drawn by the PowerBoss. This object exists only for power
+ distributors with device current monitoring support."
+ ::= { pdnEntry 36 }
+ --1.3.6.1.4.1.3052.14.1.5.4.1.1.36
+
+pdSystemCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total current drawn by all power distributors in system; that is, the
+ sum of all pdnMainCurrentValue objects for all connected power
+ distributors: internal and external."
+ ::= { pdSystem 1 }
+ --1.3.6.1.4.1.3052.14.1.5.5.1
+
+pdSystemPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power used by all power distributors in system; that is, the
+ sum of all pdnMainPowerValue objects for all connected power
+ distributors: internal and external."
+ ::= { pdSystem 2 }
+ --1.3.6.1.4.1.3052.14.1.5.5.2
+
+
+--***************************************************************************************
+--Fuel Sensor 1.5
+--***************************************************************************************
+
+fsStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FSStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor status table"
+ ::= { fuelSensorStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.6.1
+
+fsStatusEntry OBJECT-TYPE
+ SYNTAX FSStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor status table entry"
+ INDEX { fsStatusIndex }
+ ::= { fsStatusTable 1 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1
+
+fsStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for fuel sensors"
+ ::= { fsStatusEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.1
+
+fsStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor name"
+ ::= { fsStatusEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.2
+
+fsStatusDeviceState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor device state"
+ ::= { fsStatusEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.3
+
+fsStatusVolumeValueString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads
+ -999 when the fuel sensor is disconnected"
+ ::= { fsStatusEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.4
+
+fsStatusVolumePercentLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Height of the fluid in the tank expressed as a percentage of the tank
+ height, in hundredths of a percent."
+ ::= { fsStatusEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.7
+
+fsStatusVolumeInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current event status of the fuel sensor."
+ ::= { fsStatusEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.8
+
+fsStatusCombined OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`name"
+ ::= { fsStatusEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.6.1.1.9
+
+
+--***************************************************************************************
+--Wireless Modem Status Section 1.7
+--***************************************************************************************
+
+wmsStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem status"
+ ::= { wirelessModemStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.7.1
+
+wmsSignal OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Signal strength"
+ ::= { wirelessModemStatus 2 }
+ --1.3.6.1.4.1.3052.14.1.7.2
+
+wmsRSSI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Signal strength (RSSI)"
+ ::= { wirelessModemStatus 3 }
+ --1.3.6.1.4.1.3052.14.1.7.3
+
+wmsBER OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Bit Error Rate"
+ ::= { wirelessModemStatus 4 }
+ --1.3.6.1.4.1.3052.14.1.7.4
+
+wmsUpdated OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem info last update time"
+ ::= { wirelessModemStatus 5 }
+ --1.3.6.1.4.1.3052.14.1.7.5
+
+wmsRegistration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem registration status"
+ ::= { wirelessModemStatus 6 }
+ --1.3.6.1.4.1.3052.14.1.7.6
+
+wmsLAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Location Area Code"
+ ::= { wirelessModemStatus 7 }
+ --1.3.6.1.4.1.3052.14.1.7.7
+
+wmsCellID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Cell ID"
+ ::= { wirelessModemStatus 8 }
+ --1.3.6.1.4.1.3052.14.1.7.8
+
+wmsIMSI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem Internation Mobile Subscriber Identity number"
+ ::= { wirelessModemStatus 9 }
+ --1.3.6.1.4.1.3052.14.1.7.9
+
+wmsPhnum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem phone number"
+ ::= { wirelessModemStatus 10 }
+ --1.3.6.1.4.1.3052.14.1.7.10
+
+wmsLocalIP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Local IP address of modem on wireless network"
+ ::= { wirelessModemStatus 11 }
+ --1.3.6.1.4.1.3052.14.1.7.11
+
+wmsMgfID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem manufacturer ID"
+ ::= { wirelessModemStatus 12 }
+ --1.3.6.1.4.1.3052.14.1.7.12
+
+wmsModelID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem model ID"
+ ::= { wirelessModemStatus 13 }
+ --1.3.6.1.4.1.3052.14.1.7.13
+
+wmsIMEI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem International Mobile Equipment Identity number"
+ ::= { wirelessModemStatus 14 }
+ --1.3.6.1.4.1.3052.14.1.7.14
+
+wmsRevID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem revision ID"
+ ::= { wirelessModemStatus 15 }
+ --1.3.6.1.4.1.3052.14.1.7.15
+
+wmsNetName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem network name"
+ ::= { wirelessModemStatus 16 }
+ --1.3.6.1.4.1.3052.14.1.7.16
+
+wmsGPRSStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem (E)GPRS status"
+ ::= { wirelessModemStatus 17 }
+ --1.3.6.1.4.1.3052.14.1.7.17
+
+wmsBand OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem band"
+ ::= { wirelessModemStatus 18 }
+ --1.3.6.1.4.1.3052.14.1.7.18
+
+wmsChannel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem channel"
+ ::= { wirelessModemStatus 19 }
+ --1.3.6.1.4.1.3052.14.1.7.19
+
+wmsCountryCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem country code"
+ ::= { wirelessModemStatus 20 }
+ --1.3.6.1.4.1.3052.14.1.7.20
+
+wmsNetCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem network code"
+ ::= { wirelessModemStatus 21 }
+ --1.3.6.1.4.1.3052.14.1.7.21
+
+wmsPLMNColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem PLMN color"
+ ::= { wirelessModemStatus 22 }
+ --1.3.6.1.4.1.3052.14.1.7.22
+
+wmsBScolor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem BS color"
+ ::= { wirelessModemStatus 23 }
+ --1.3.6.1.4.1.3052.14.1.7.23
+
+wmsMpRACH OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem max power RACH"
+ ::= { wirelessModemStatus 24 }
+ --1.3.6.1.4.1.3052.14.1.7.24
+
+wmsMinRxLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem minimum receive level"
+ ::= { wirelessModemStatus 25 }
+ --1.3.6.1.4.1.3052.14.1.7.25
+
+wmsBaseCoeff OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem base coefficient"
+ ::= { wirelessModemStatus 26 }
+ --1.3.6.1.4.1.3052.14.1.7.26
+
+wmsSIMStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "WWireless modem SIM status"
+ ::= { wirelessModemStatus 27 }
+ --1.3.6.1.4.1.3052.14.1.7.27
+
+wmsICCID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem SIM ICCID"
+ ::= { wirelessModemStatus 28 }
+ --1.3.6.1.4.1.3052.14.1.7.28
+
+wmsModemType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wireless modem type"
+ ::= { wirelessModemStatus 29 }
+ --1.3.6.1.4.1.3052.14.1.7.29
+
+
+--***************************************************************************************
+--AC Power Monitor Section 1.8
+--***************************************************************************************
+
+acpmStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "AC power monitor status table"
+ ::= { acPowerMonitorStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.8.1
+
+acpmStatusEntry OBJECT-TYPE
+ SYNTAX ACPMStatus
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "AC power monitor status table entry"
+ INDEX { acpmsIndex }
+ ::= { acpmStatusTable 1 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1
+
+acpmsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AC power monitors"
+ ::= { acpmStatusEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.1
+
+acpmsName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name for the AC power monitor device."
+ ::= { acpmStatusEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.2
+
+acpmsAvgVoltageValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1). This could be either the average of
+ the phase voltages, or the sum of the phase voltages, depending
+ on device configuration."
+ ::= { acpmStatusEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.3
+
+acpmsAvgVoltageMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum average voltage value since last reset, in volts."
+ ::= { acpmStatusEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.4
+
+acpmsAvgVoltageMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum average voltage value since last reset, in volts."
+ ::= { acpmStatusEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.5
+
+acpmsAvgVoltageAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average average voltage value since last reset, in volts. This is
+ the unit's average of its measurements of the average voltage
+ reported by the AC power monitor device."
+ ::= { acpmStatusEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.6
+
+acpmsAvgVoltageInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor voltage (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.7
+
+acpmsVoltagePhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.8
+
+acpmsVoltagePhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.9
+
+acpmsVoltagePhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C voltage, in volts. This is calculated using the formula
+ (register * PT ratio * 0.1)."
+ ::= { acpmStatusEntry 10 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.10
+
+acpmsAvgCurrentValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001). This could be either the average of
+ the phase currents, or the sum of the phase currents, depending on
+ device configuration."
+ ::= { acpmStatusEntry 11 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.11
+
+acpmsAvgCurrentMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum average current value since last reset, in amps."
+ ::= { acpmStatusEntry 12 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.12
+
+acpmsAvgCurrentMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum average current value since last reset, in amps."
+ ::= { acpmStatusEntry 13 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.13
+
+acpmsAvgCurrentAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average average current value since last reset, in amps. This is
+ the unit's average of its measurements of the average current reported
+ by the AC power monitor device."
+ ::= { acpmStatusEntry 14 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.14
+
+acpmsAvgCurrentInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor current (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 15 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.15
+
+acpmsCurrentPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 16 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.16
+
+acpmsCurrentPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 17 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.17
+
+acpmsCurrentPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C current, in amps. This is calculated using the formula
+ (register * CT ratio * 0.001)."
+ ::= { acpmStatusEntry 18 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.18
+
+acpmsAvgFreqValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Frequency, in hertz. On the YD2010, this is calculated using the
+ formula (register * 0.00106813). On the WattsOn, this is calculated
+ using the formula (register * 0.1)."
+ ::= { acpmStatusEntry 19 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.19
+
+acpmsAvgFreqMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum frequency value since last reset, in hertz."
+ ::= { acpmStatusEntry 20 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.20
+
+acpmsAvgFreqMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum frequency value since last reset, in hertz."
+ ::= { acpmStatusEntry 21 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.21
+
+acpmsAvgFreqAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average frequency value since last reset, in hertz. This is the
+ unit's average of its measurements of the average frequency reported
+ by the AC power monitor device."
+ ::= { acpmStatusEntry 22 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.22
+
+acpmsAvgFreqInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor frequency (Low, Normal, High, etc.)."
+ ::= { acpmStatusEntry 23 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.23
+
+acpmsTRPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn models,
+ this is calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 24 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.24
+
+acpmsTRPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum total real power value since last reset, in watts."
+ ::= { acpmStatusEntry 25 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.25
+
+acpmsTRPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum total real power value since last reset, in watts."
+ ::= { acpmStatusEntry 26 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.26
+
+acpmsTRPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average total real power value since last reset, in watts. This is
+ the unit's average of its measurements of the average total real power
+ reported by the AC power monitor device."
+ ::= { acpmStatusEntry 27 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.27
+
+acpmsTRPInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event state of this AC power monitor total real power (Low, Normal,
+ High, etc.)."
+ ::= { acpmStatusEntry 28 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.28
+
+acpmsRPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 29 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.29
+
+acpmsRPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 30 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.30
+
+acpmsRPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C real power, in watts. On the YD2010, this is calculated using
+ the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
+ the voltage range taken from register 0x30A. On the WattsOn, this is
+ calculated using the formula (register * PT * CT)."
+ ::= { acpmStatusEntry 31 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.31
+
+acpmsCombined OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`freuencyColorCode`powerEventState`powerColorCode"
+ ::= { acpmStatusEntry 32 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.32
+
+acpmsTPFValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor."
+ ::= { acpmStatusEntry 33 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.33
+
+acpmsTPFMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor minimum value since last reset."
+ ::= { acpmStatusEntry 34 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.34
+
+acpmsTPFMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor maximum value since last reset."
+ ::= { acpmStatusEntry 35 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.35
+
+acpmsTPFAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor average value since last reset."
+ ::= { acpmStatusEntry 36 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.36
+
+acpmsTPFInEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total power factor event state."
+ ::= { acpmStatusEntry 37 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.37
+
+acpmsPFPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A power factor."
+ ::= { acpmStatusEntry 38 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.38
+
+acpmsPFPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B power factor."
+ ::= { acpmStatusEntry 39 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.39
+
+acpmsPFPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C power factor."
+ ::= { acpmStatusEntry 40 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.40
+
+acpmsTRcPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power, in VAR."
+ ::= { acpmStatusEntry 41 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.41
+
+acpmsTRcPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power minimum value since last reset, in VAR."
+ ::= { acpmStatusEntry 42 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.42
+
+acpmsTRcPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power maximum value since last reset, in VAR."
+ ::= { acpmStatusEntry 43 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.43
+
+acpmsTRcPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive power average value since last reset, in VAR."
+ ::= { acpmStatusEntry 44 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.44
+
+acpmsRcPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A reactive power, in VAR."
+ ::= { acpmStatusEntry 45 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.45
+
+acpmsRcPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B reactive power, in VAR."
+ ::= { acpmStatusEntry 46 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.46
+
+acpmsRcPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C reactive power, in VAR."
+ ::= { acpmStatusEntry 47 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.47
+
+acpmsTAPValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power, in VA."
+ ::= { acpmStatusEntry 48 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.48
+
+acpmsTAPMinStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power minimum value since last reset, in VA."
+ ::= { acpmStatusEntry 49 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.49
+
+acpmsTAPMaxStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power maximum value since last reset, in VA."
+ ::= { acpmStatusEntry 50 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.50
+
+acpmsTAPAvgStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent power average value since last reset, in VA."
+ ::= { acpmStatusEntry 51 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.51
+
+acpmsAPPhaseAValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase A apparent power, in VA."
+ ::= { acpmStatusEntry 52 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.52
+
+acpmsAPPhaseBValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase B apparent power, in VA."
+ ::= { acpmStatusEntry 53 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.53
+
+acpmsAPPhaseCValueStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Phase C apparent power, in VA."
+ ::= { acpmStatusEntry 54 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.54
+
+acpmsTotalEnergyWh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total energy, in Wh."
+ ::= { acpmStatusEntry 55 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.55
+
+acpmsTotalEnergyVAR OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total reactive energy, in VAR."
+ ::= { acpmStatusEntry 56 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.56
+
+acpmsTotalEnergyVA OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total apparent energy, in VA."
+ ::= { acpmStatusEntry 57 }
+ --1.3.6.1.4.1.3052.14.1.8.1.1.57
+
+
+
+--***************************************************************************************
+--AISG Status Section 1.9
+--***************************************************************************************
+
+aisgsPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "AISG power state"
+ ::= { aisgStatus 1 }
+ --1.3.6.1.4.1.3052.14.1.9.1
+
+aisgsBaseStationID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "AISG base station ID"
+ ::= { aisgStatus 2 }
+ --1.3.6.1.4.1.3052.14.1.9.2
+
+aisgsALDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AISGALD
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of what AISG ALDs (Antenna Line Devices) are attached to the unit."
+ ::= { aisgStatus 3 }
+ --1.3.6.1.4.1.3052.14.1.9.3
+
+aisgsALDEntry OBJECT-TYPE
+ SYNTAX AISGALD
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for AISG ALD table"
+ INDEX { aisgsALDIndex }
+ ::= { aisgsALDTable 1 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1
+
+aisgsALDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..18)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This number refers to an ALD; it is the ALD # as shown
+ in the web UI and CLI."
+ ::= { aisgsALDEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.1
+
+aisgsALDSectorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The sector ID of this ALD."
+ ::= { aisgsALDEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.2
+
+aisgsALDType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of ALD (SR or MR)."
+ ::= { aisgsALDEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.3
+
+aisgsALDDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "User-defined description for this ALD."
+ ::= { aisgsALDEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.4
+
+aisgsALDStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of this ALD (i.e., OFF, OK, UNRSP, ALARM)."
+ ::= { aisgsALDEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.5
+
+aisgsALDID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID/serial number of this ALD."
+ ::= { aisgsALDEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.6
+
+aisgsALDTilt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current tilt value of this ALD."
+ ::= { aisgsALDEntry 7 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.7
+
+aisgsALDHwVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The hardware version of this ALD."
+ ::= { aisgsALDEntry 8 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.8
+
+aisgsALDSwVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The software version of this ALD."
+ ::= { aisgsALDEntry 9 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.9
+
+aisgsALDModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model number of this ALD."
+ ::= { aisgsALDEntry 10 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.10
+
+aisgsALDAntennaModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model number of the antenna associated with this ALD.
+ Note that not all ALDs have this."
+ ::= { aisgsALDEntry 11 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.11
+
+aisgsALDMinTilt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum tilt value of this ALD, as determined by the ALD's
+ loaded configuration file. A nonsensical value here indicates
+ that the ALD is not configured."
+ ::= { aisgsALDEntry 12 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.12
+
+aisgsALDMaxTilt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum tilt value of this ALD, as determined by the ALD's
+ loaded configuration file. A nonsensical value here indicates
+ that the ALD is not configured."
+ ::= { aisgsALDEntry 13 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.13
+
+aisgsALDAISGVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The AISG version of this ALD. E.g., 1.1, 2.0."
+ ::= { aisgsALDEntry 14 }
+ --1.3.6.1.4.1.3052.14.1.9.3.1.14
+
+aisgsFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AISGFile
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of what AISG files are currently loaded on the unit."
+ ::= { aisgStatus 4 }
+ --1.3.6.1.4.1.3052.14.1.9.4
+
+aisgsFileEntry OBJECT-TYPE
+ SYNTAX AISGFile
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for AISG File table"
+ INDEX { aisgsFileIndex }
+ ::= { aisgsFileTable 1 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1
+
+aisgsFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AISG File table. This defines the local store (local to
+ the unit) of files residing on the unit that are available to be
+ loaded onto ALDs."
+ ::= { aisgsFileEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1.1
+
+aisgsFileName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name of AISG file (specified by user)."
+ ::= { aisgsFileEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1.2
+
+aisgsFileType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of AISG file (e.g., SOFTWARE or CONFIG)"
+ ::= { aisgsFileEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1.3
+
+aisgsFileVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Version of AISG file as reported by the ALD running this software.
+ This is for SOFTWARE files, so that the unit can know when (during
+ auto config) it does not need to load software onto an ALD (i.e.,
+ if the ALD already has this software version loaded)."
+ ::= { aisgsFileEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.9.4.1.4
+
+aisgsAutoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AISGAuto
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of AISG automatic configuration slots on the unit. These
+ slots describe what the unit should do automatically (load software,
+ load config, calibrate, tilt) upon finding the ALD during a scan, on
+ the specific basis of any ALD matching the vendor and ALD model defined
+ in a row of this table."
+ ::= { aisgStatus 5 }
+ --1.3.6.1.4.1.3052.14.1.9.5
+
+aisgsAutoEntry OBJECT-TYPE
+ SYNTAX AISGAuto
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for AISG Auto table"
+ INDEX { aisgsAutoIndex }
+ ::= { aisgsAutoTable 1 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1
+
+aisgsAutoIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AISG Auto table."
+ ::= { aisgsAutoEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.1
+
+aisgsAutoVendor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The two-letter vendor code for this automatic configuration table row."
+ ::= { aisgsAutoEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.2
+
+aisgsAutoALDModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ALD model number this automatic configuration table row."
+ ::= { aisgsAutoEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.3
+
+aisgsAutoSoftware OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The software file name of this automatic configuration table row."
+ ::= { aisgsAutoEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.4
+
+aisgsAutoConfig OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The configuration file name of this automatic configuration table row."
+ ::= { aisgsAutoEntry 5 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.5
+
+aisgsAutoTilt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The tilt value for this automatic configuration table row. Any ALD not
+ already auto-configured by the unit will be tilted to this value, if its
+ vendor and model number match the vendor and ALD model number of this
+ table row."
+ ::= { aisgsAutoEntry 6 }
+ --1.3.6.1.4.1.3052.14.1.9.5.1.6
+
+
+aisgsAAATable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AISGAAA
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of AISG antenna-ALD associations slots on the unit. These
+ slots describe what antenna serial number and what sector ID the unit
+ should assign to an ALD that is undergoing automatic configuration."
+ ::= { aisgStatus 6 }
+ --1.3.6.1.4.1.3052.14.1.9.6
+
+aisgsAAAEntry OBJECT-TYPE
+ SYNTAX AISGAAA
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for AISG AAA table"
+ INDEX { aisgsAAAIndex }
+ ::= { aisgsAAATable 1 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1
+
+aisgsAAAIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for AISG AAA table."
+ ::= { aisgsAAAEntry 1 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1.1
+
+aisgsAAAALDID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID/serial number of the ALD for this AAA table row."
+ ::= { aisgsAAAEntry 2 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1.2
+
+aisgsAAAAntennaSN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-specified antenna serial number for this AAA table row.
+ An ALD that the unit finds with this ID/serial number will be
+ assigned this antenna serial number. This happens only during
+ auto-configuration of the ALD, which happens only once for an ALD."
+ ::= { aisgsAAAEntry 3 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1.3
+
+aisgsAAASectorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-specified sector ID for this AAA table row.
+ An ALD that the unit finds with this ID/serial number will be
+ assigned this sector ID. This happens only during auto-configuration
+ of the ALD, which happens only once for an ALD."
+ ::= { aisgsAAAEntry 4 }
+ --1.3.6.1.4.1.3052.14.1.9.6.1.4
+
+
+--***************************************************************************************
+--EventSensor Basics Section 2.1
+--***************************************************************************************
+
+esNumberEventSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of EventSensors recognized by the unit,
+ including the internal EventSensor.
+ Range: 1-17"
+ ::= { eventSensorBasics 1 }
+ --1.3.6.1.4.1.3052.14.2.1.1
+
+esTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESExist
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of what EventSensors are attached to the unit,
+ including the internal EventSensor"
+ ::= { eventSensorBasics 2 }
+ --1.3.6.1.4.1.3052.14.2.1.2
+
+esEntry OBJECT-TYPE
+ SYNTAX ESExist
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for EventSensor table"
+ INDEX { esIndex }
+ ::= { esTable 1 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1
+
+esIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This number refers to an EventSensor; it has the
+ same meaning as the esIndexES object (see above),
+ except that this object is used only within the
+ esTable branch.
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndex=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.1
+
+esName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the EventSensor"
+ ::= { esEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.2
+
+esID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The factory-assigned ID of the EventSensor"
+ ::= { esEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.3
+
+esNumberTempSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of temperature sensors on the EventSensor"
+ ::= { esEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.4
+
+esTempReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how temperature values should
+ be interpreted."
+ ::= { esEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.5
+
+esNumberCCs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of contact closures on the EventSensor."
+ ::= { esEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.6
+
+esCCReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how CC values should be interpreted."
+ ::= { esEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.7
+
+esNumberHumidSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of humidity sensors on the EventSensor."
+ ::= { esEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.8
+
+esHumidReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how humidity sensor values should be
+ interpreted."
+ ::= { esEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.9
+
+esNumberNoiseSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of noise sensors on the EventSensor."
+ ::= { esEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.10
+
+esNoiseReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how noise sensor values should be
+ interpreted."
+ ::= { esEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.11
+
+esNumberAirflowSensors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of airflow sensors on the EventSensor."
+ ::= { esEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.12
+
+esAirflowReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how airflow sensor values should be
+ interpreted."
+ ::= { esEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.13
+
+esNumberAnalog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of analog inputs on the EventSensor."
+ ::= { esEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.14
+
+esAnalogReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how analog input values should be
+ interpreted."
+ ::= { esEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.15
+
+esNumberOutputs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs (relay or power) on the EventSensor"
+ ::= { esEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.16
+
+esOutputReportingMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of how output values should be interpreted."
+ ::= { esEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.17
+
+esTempCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`value`scale`eventState`eventColorCode"
+ ::= { esEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.18
+
+esCCCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8"
+ ::= { esEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.19
+
+esCCCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16"
+ ::= { esEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.20
+
+esCCCombinedStatusBlock3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24"
+ ::= { esEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.21
+
+esCCCombinedStatusBlock4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32"
+ ::= { esEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.22
+
+esCCCombinedStatusBlock5 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40"
+ ::= { esEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.23
+
+esCCCombinedStatusBlock6 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48"
+ ::= { esEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.24
+
+esCCCombinedStatusBlock7 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56"
+ ::= { esEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.25
+
+esCCCombinedStatusBlock8 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64"
+ ::= { esEntry 26 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.26
+
+esHumidCombinedStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ name`value`eventState`eventColorCode"
+ ::= { esEntry 27 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.27
+
+esAnalogCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~..."
+ ::= { esEntry 28 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.28
+
+esAnalogCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~name9`value9`units9`eventState9`eventColorCode9~..."
+ ::= { esEntry 29 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.29
+
+esAnalogCombinedStatusBlock3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 30 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.31
+
+esAnalogCombinedStatusBlock4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 31 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.31
+
+esAnalogCombinedStatusBlock5 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 32 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.32
+
+esAnalogCombinedStatusBlock6 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 33 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.33
+
+esOutputCombinedStatusBlock1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
+ ::= { esEntry 34 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.34
+
+esOutputCombinedStatusBlock2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Combined status string intended to be parsed by NMS:
+ numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz"
+ ::= { esEntry 35 }
+ --1.3.6.1.4.1.3052.14.2.1.2.1.35
+
+
+esNewSensors OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "String representing the number of new (attached but unconfigured) EventSensors"
+ ::= { eventSensorBasics 3 }
+ --1.3.6.1.4.1.3052.14.2.1.3
+
+
+--***************************************************************************************
+--EventSensor Point Config Section 2.2
+--***************************************************************************************
+
+
+
+esPointConfigTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigTemp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of temperature
+ sensor points. A point is a particular sensor on an
+ EventSensor. The 3 point attributes organizes in this table
+ are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number (always 1 for temp sensors)
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by periods.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ emperature point config table ; namely, which EventSensor,
+ and which sensor (a.k.a. point) (always 1 for temperature
+ sensors).
+ "
+ ::= { eventSensorPointConfig 1 }
+ --1.3.6.1.4.1.3052.14.2.2.1
+
+esPointConfigTempEntry OBJECT-TYPE
+ SYNTAX ESPointConfigTemp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config temperature table"
+ INDEX { espcTempIndexES, espcTempIndexPoint }
+ ::= { esPointConfigTempTable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1
+
+espcTempIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config temperature table; namely, which EventSensor,
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+
+ The number corresponding to an EventSensor is
+ determined by the user at the initial configuration
+ time. If there is an internal sensor in the unit,
+ it will always be the first item in the Sensor
+ Events setup menu.
+
+ For example, if a new EventSensor is configured as
+ the 2nd entry AFTER the internal EventSensor (if
+ one exists) in the Sensor Events Setup Menu, then
+ that EventSensor will be known from then on as
+ EventSensor 2. All point indeces with esIndexES=2
+ will now refer to that particular EventSensor.
+ "
+ ::= { esPointConfigTempEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.1
+
+espcTempIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcTempIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of temperature point configuration."
+ ::= { esPointConfigTempEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.2
+
+espcTempEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this temperature sensor"
+ ::= { esPointConfigTempEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.3
+
+espcTempScale OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Scale (C/F) for this temperature sensor"
+ ::= { esPointConfigTempEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.4
+
+espcTempDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this temperature sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.5
+
+espcTempVHighTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.6
+
+espcTempVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event actions for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.7
+
+espcTempVHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event trap number for this
+ temperature sensor"
+ ::= { esPointConfigTempEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.8
+
+espcTempVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high temperature event class for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.9
+
+espcTempHighTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.10
+
+espcTempHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.11
+
+espcTempHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.12
+
+espcTempHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.13
+
+espcTempNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.14
+
+espcTempNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.15
+
+espcTempNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.16
+
+espcTempLowTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event threshold for this temperature sensor
+ (in floating-point format)"
+ ::= { esPointConfigTempEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.17
+
+espcTempLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event actions for this temperature sensor"
+ ::= { esPointConfigTempEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.18
+
+espcTempLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.19
+
+espcTempLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.20
+
+espcTempVLowTemp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event threshold for this temperature
+ sensor (in floating-point format)"
+ ::= { esPointConfigTempEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.21
+
+espcTempVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event actions for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.22
+
+espcTempVLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event trap number for this temperature
+ sensor"
+ ::= { esPointConfigTempEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.23
+
+espcTempVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low temperature event class for this temperature sensor"
+ ::= { esPointConfigTempEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.2.1.1.24
+
+
+
+
+
+esPointConfigCCTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigCC
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of contact closure
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor within the context of this
+ contact closure point config table ; namely, which
+ EventSensor and which sensor.
+ "
+ ::= { eventSensorPointConfig 2 }
+ --1.3.6.1.4.1.3052.14.2.2.2
+
+esPointConfigCCEntry OBJECT-TYPE
+ SYNTAX ESPointConfigCC
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config contact closure table"
+ INDEX { espcCCIndexES, espcCCIndexPoint }
+ ::= { esPointConfigCCTable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1
+
+espcCCIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigCCEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.1
+
+espcCCIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcCCIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigCCEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.2
+
+espcCCEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable for this contact closure"
+ ::= { esPointConfigCCEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.3
+
+espcCCName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this contact closure"
+ ::= { esPointConfigCCEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.4
+
+espcCCEventState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event state for this contact closure"
+ ::= { esPointConfigCCEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.5
+
+espcCCThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event threshold (seconds) for this contact closure"
+ ::= { esPointConfigCCEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.6
+
+espcCCEventActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event actions for this contact closure"
+ ::= { esPointConfigCCEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.7
+
+espcCCEventTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event trap number for this contact closure"
+ ::= { esPointConfigCCEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.8
+
+espcCCEventClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event class for this contact closure"
+ ::= { esPointConfigCCEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.9
+
+espcCCNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this contact closure"
+ ::= { esPointConfigCCEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.10
+
+espcCCNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this contact closure"
+ ::= { esPointConfigCCEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.11
+
+espcCCNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this contact closure"
+ ::= { esPointConfigCCEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.12
+
+espcCCAlarmAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event alias for this contact closure"
+ ::= { esPointConfigCCEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.13
+
+espcCCNormalAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal alias for this contact closure"
+ ::= { esPointConfigCCEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.14
+
+espcCCNormalThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Event threshold (seconds) for this contact closure to return to normal"
+ ::= { esPointConfigCCEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.15
+
+espcCCOverrideGlobalReminder OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Override global reminder interval (evReminderInterval) for this CC."
+ ::= { esPointConfigCCEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.16
+
+espcCCReminderInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Individual reminder interval for this CC, applicable when the global
+ reminder is overriden."
+ ::= { esPointConfigCCEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.2.2.1.17
+
+
+esPointConfigHumidTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigHumid
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of humidity points.
+ A point is a particular sensor on an EventSensor. The 3
+ point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number (always 1 for humidity sensors)
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a piece
+ of data off an event sensor within the context of this
+ humidity point config table ; namely, which EventSensor and
+ which sensor.
+ "
+ ::= { eventSensorPointConfig 3 }
+ --1.3.6.1.4.1.3052.14.2.2.3
+
+esPointConfigHumidEntry OBJECT-TYPE
+ SYNTAX ESPointConfigHumid
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config humidity table"
+ INDEX { espcHumidIndexES, espcHumidIndexPoint }
+ ::= { esPointConfigHumidTable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1
+
+espcHumidIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigHumidEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.1
+
+espcHumidIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcHumidIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigHumidEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.2
+
+espcHumidEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable for this humidity sensor"
+ ::= { esPointConfigHumidEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.3
+
+espcHumidDeadband OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this humidity sensor"
+ ::= { esPointConfigHumidEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.4
+
+espcHumidVHighHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.5
+
+espcHumidVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.6
+
+espcHumidVHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.7
+
+espcHumidVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.8
+
+espcHumidHighHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.9
+
+espcHumidHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.10
+
+espcHumidHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.11
+
+espcHumidHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.12
+
+espcHumidNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.13
+
+espcHumidNormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.14
+
+espcHumidNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.15
+
+espcHumidLowHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.16
+
+espcHumidLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.17
+
+espcHumidLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.18
+
+espcHumidLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.19
+
+espcHumidVLowHumid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold for this humidity sensor"
+ ::= { esPointConfigHumidEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.20
+
+espcHumidVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this humidity sensor"
+ ::= { esPointConfigHumidEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.21
+
+espcHumidVLowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number for this humidity sensor"
+ ::= { esPointConfigHumidEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.22
+
+espcHumidVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class for this humidity sensor"
+ ::= { esPointConfigHumidEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.2.3.1.23
+
+
+esPointConfigAITable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigAnalogInput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes 3 basic attributes of analog input
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organizes in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ analog input point config table ; namely, which EventSensor
+ and which sensor.
+ "
+ ::= { eventSensorPointConfig 5 }
+ --1.3.6.1.4.1.3052.14.2.2.5
+
+esPointConfigAIEntry OBJECT-TYPE
+ SYNTAX ESPointConfigAnalogInput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config analog input table"
+ INDEX { espcHumidIndexES, espcHumidIndexPoint }
+ ::= { esPointConfigAITable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1
+
+espcAIIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigAIEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.1
+
+espcAIIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcAIIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of contact closure point configuration."
+ ::= { esPointConfigAIEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.2
+
+espcAIEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for this analog input sensor"
+ ::= { esPointConfigAIEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.3
+
+espcAIDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband for this analog input sensor"
+ ::= { esPointConfigAIEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.5
+
+espcAIVhighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold (decivolts or tenths of
+ milliamps) for this analog input sensor"
+ ::= { esPointConfigAIEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.6
+
+espcAIVhighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.7
+
+espcAIVhighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.8
+
+espcAIVhighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.9
+
+espcAIHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold (decivolts or tenths of milliamps) for
+ this analog input sensor"
+ ::= { esPointConfigAIEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.10
+
+espcAIHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.11
+
+espcAIHighTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.12
+
+espcAIHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.13
+
+espcAINormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.14
+
+espcAINormalTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.15
+
+espcAINormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return-to-normal class for this analog input sensor"
+ ::= { esPointConfigAIEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.16
+
+espcAILowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold (decivolts or tenths of milliamps) for
+ this analog input sensor"
+ ::= { esPointConfigAIEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.17
+
+espcAILowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.18
+
+espcAILowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number for this analog input sensor"
+ ::= { esPointConfigAIEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.19
+
+espcAILowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.20
+
+espcAIVlowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold (decivolts or tenths of milliamps)
+ for this analog input sensor"
+ ::= { esPointConfigAIEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.21
+
+espcAIVlowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.22
+
+espcAIVlowTrapnum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions for this analog input sensor"
+ ::= { esPointConfigAIEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.23
+
+espcAIVlowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class for this analog input sensor"
+ ::= { esPointConfigAIEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.24
+
+espcAIConvUnitName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Converstion unit name for this analog input sensor"
+ ::= { esPointConfigAIEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.25
+
+espcAIConvHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion high value for this analog input sensor"
+ ::= { esPointConfigAIEntry 26 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.26
+
+espcAIConvHighUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion high unit value for this analog input sensor"
+ ::= { esPointConfigAIEntry 27 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.27
+
+espcAIConvLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion low value for this analog input sensor"
+ ::= { esPointConfigAIEntry 29 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.29
+
+espcAIConvLowUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Conversion unit low unit value for this analog input sensor"
+ ::= { esPointConfigAIEntry 30 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.30
+
+espcAIDisplayFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input display format"
+ ::= { esPointConfigAIEntry 32 }
+ --1.3.6.1.4.1.3052.14.2.2.5.1.32
+
+esPointConfigOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESPointConfigOutput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes configuration items for output
+ points. A point is a particular sensor on an EventSensor.
+ The 3 point attributes organized in this table are:
+ 1. the configuration item (e.g., enable, name, etc.)
+ 2. the eventsensor on which this point resides
+ 3. the point number
+
+ Points are referenced by a point config index. The point
+ config index is a string of 2 numbers separated by a period.
+ It contains all the information necessary for getting a
+ piece of data off an event sensor within the context of this
+ output config table ; namely, which EventSensor
+ and which sensor.
+ "
+ ::= { eventSensorPointConfig 6 }
+ --1.3.6.1.4.1.3052.14.2.2.6
+
+esPointConfigOutputEntry OBJECT-TYPE
+ SYNTAX ESPointConfigOutput
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for EventSensor point config output table"
+ INDEX { espcOutputIndexES, espcOutputIndexPoint }
+ ::= { esPointConfigOutputTable 1 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1
+
+espcOutputIndexES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that refers to an
+ EventSensor.
+
+ The point config index is a string of 2 numbers separated
+ by a period. It contains all the information
+ necessary for getting a piece of data off an event
+ sensor within the the context of the eventsensor point
+ config contact closure table; namely, which EventSensor
+ and which sensor (a.k.a. point).
+
+ This object's allowable values are 1 through 16,
+ and 200. 200 always refers to the EventSensor
+ inside the unit. 1 through 16 refer to additional
+ attached EventSensors.
+ "
+ ::= { esPointConfigOutputEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.1
+
+espcOutputIndexPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part of the point index that delineates which
+ sensor on the EventSensor.
+
+ So this combined with espcOutputIndexES (which EventSensor)
+ uniquely defines each point attached to a unit within the
+ context of output point configuration."
+ ::= { esPointConfigOutputEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.2
+
+espcOutputEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enables the output event for this output. This has no effect
+ on whether the relay changes state, only on whether a state change
+ triggers an event."
+ ::= { esPointConfigOutputEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.3
+
+espcOutputActiveState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which state is considered the active state: energized/de-energized."
+ ::= { esPointConfigOutputEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.4
+
+espcOutputType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output type: RELAY, POWER, SSR, TTL."
+ ::= { esPointConfigOutputEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.5
+
+espcOutputAliasValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output alias corresponding to its event state."
+ ::= { esPointConfigOutputEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.6
+
+espcOutputAliasColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output color corresponding to its event state."
+ ::= { esPointConfigOutputEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.7
+
+espcOutputActiveAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alias for the output active state."
+ ::= { esPointConfigOutputEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.10
+
+espcOutputActiveColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output color (as rendered in the web UI, in RGB hex format) corresponding
+ to the output active state."
+ ::= { esPointConfigOutputEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.11
+
+espcOutputActiveActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output active event."
+ ::= { esPointConfigOutputEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.12
+
+espcOutputActiveTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (150..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output active event."
+ ::= { esPointConfigOutputEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.13
+
+espcOutputActiveClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the output active event."
+ ::= { esPointConfigOutputEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.14
+
+espcOutputInactiveAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alias for the output inactive state."
+ ::= { esPointConfigOutputEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.20
+
+espcOutputInactiveColor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output color (as rendered in the web UI, in RGB hex format) corresponding
+ to the output inactive state."
+ ::= { esPointConfigOutputEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.21
+
+espcOutputInactiveActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output inactive event."
+ ::= { esPointConfigOutputEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.22
+
+espcOutputInactiveTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (150..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the output inactive event."
+ ::= { esPointConfigOutputEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.23
+
+espcOutputInactiveClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for the output inactive event."
+ ::= { esPointConfigOutputEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.2.6.1.24
+
+
+--***************************************************************************************
+--Serial Port Section 2.3
+--***************************************************************************************
+
+numberPorts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of RS-232 ports found.
+ Range: 2 or 4"
+ ::= { serialPorts 1 }
+ --1.3.6.1.4.1.3052.14.2.3.1
+
+portConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port config table"
+ ::= { serialPorts 2 }
+ --1.3.6.1.4.1.3052.14.2.3.2
+
+portConfigEntry OBJECT-TYPE
+ SYNTAX PortConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port config entry"
+ INDEX { portConfigIndex }
+ ::= { portConfigTable 1 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1
+
+portConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for ports"
+ ::= { portConfigEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.1
+
+portConfigBaud OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Baud rate, 19200, 9600, etc."
+ ::= { portConfigEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.2
+
+portConfigDataFormat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Value representing word length, parity, and
+ stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2"
+ ::= { portConfigEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.3
+
+portConfigStripPtOutputLfs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Strip passthrough LFs sent to device on this port:
+ 1=yes, 0=no."
+ ::= { portConfigEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.4
+
+portConfigStripPtInputLfs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Strip passthrough LFs received from device on this
+ port: 1=yes, 0=no."
+ ::= { portConfigEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.5
+
+portConfigMaskEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1=Use the character mask on this port. 0=Do
+ not use the mask. When the mask is enabled,
+ the following ASCII characters are ignored
+ on the port:
+ 0, 1, 4-9, 11, 12, 14-31, 128-255.
+ When the mask is disabled, all characters are
+ accepted on the port."
+ ::= { portConfigEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.7
+
+portConfigDAEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1=Enable the Data Alarm Evaluator for data
+ on this port. 0=Do not evaluate data on this
+ port."
+ ::= { portConfigEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.8
+
+portConfigStoreAlarmsDPT OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: store alarms received during passthrough"
+ ::= { portConfigEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.9
+
+portConfigRecordTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout after last unterminated data received upon
+ which data collected so far is stored as a record."
+ ::= { portConfigEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.10
+
+portConfigDataType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How the port interprets incoming data: ASCII/BINARY"
+ ::= { portConfigEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.11
+
+portConfigEtxToCRLF OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF whether the port translates incoming ETX to CRLF"
+ ::= { portConfigEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.12
+
+portConfigMLREnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Whether Multiline Records are collected on this port."
+ ::= { portConfigEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.13
+
+portConfigMLRStartField1Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR start field 1"
+ ::= { portConfigEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.14
+
+portConfigMLRStartField1Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR start field 1"
+ ::= { portConfigEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.15
+
+portConfigMLRStartField2Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR start field 2"
+ ::= { portConfigEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.16
+
+portConfigMLRStartField2Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR start field 2"
+ ::= { portConfigEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.17
+
+portConfigMLRNumLinesBefore OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of lines before the starting line which should
+ be included in the MLR"
+ ::= { portConfigEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.18
+
+portConfigMLREndDetection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How the MLR parser determines what ends an MLR: by FORMULA,
+ number of lines received so far (COUNT), or number of blank
+ lines received so far (BLANKS)"
+ ::= { portConfigEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.19
+
+portConfigMLRLineCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of lines in the MLR (used by the end detection mode)"
+ ::= { portConfigEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.20
+
+portConfigMLREndField1Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR end field 1"
+ ::= { portConfigEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.21
+
+portConfigMLREndField1Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR end field 1"
+ ::= { portConfigEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.22
+
+portConfigMLREndField2Pos OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Position of MLR end field 2"
+ ::= { portConfigEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.23
+
+portConfigMLREndField2Text OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text to match MLR end field 2"
+ ::= { portConfigEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.24
+
+portConfigMLRUseComplexRules OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF MLR parser uses complex rules (field possitions/
+ formulas, etc.)"
+ ::= { portConfigEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.25
+
+portConfigBufferPT OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF records received during passthrough mode are
+ buffered/stored in the database"
+ ::= { portConfigEntry 26 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.26
+
+portConfigId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The text identifer for the port"
+ ::= { portConfigEntry 27 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.27
+
+portConfigMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Mode of the serial port."
+ ::= { portConfigEntry 28 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.28
+
+portConfigHsk OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Handshaking mode of the serial port."
+ ::= { portConfigEntry 29 }
+ --1.3.6.1.4.1.3052.14.2.3.2.1.29
+
+--***************************************************************************************
+--Network Section 2.4
+--***************************************************************************************
+
+eth1Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of the Ethernet1 interface: STATIC,DHCP,VLAN"
+ ::= { ethernet1 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.1
+
+eth1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 IP address"
+ ::= { ethernet1 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.2
+
+eth1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 subnet mask"
+ ::= { ethernet1 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.3
+
+eth1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 router"
+ ::= { ethernet1 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.4
+
+-- Ethernet1 VLAN1
+
+eth1VLAN1ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 ID"
+ ::= { eth1VLAN1 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.1
+
+eth1VLAN1Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 priority"
+ ::= { eth1VLAN1 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.2
+
+eth1VLAN1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 IP address"
+ ::= { eth1VLAN1 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.3
+
+eth1VLAN1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 subnet mask"
+ ::= { eth1VLAN1 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.4
+
+eth1VLAN1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN1 router"
+ ::= { eth1VLAN1 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.1.5
+
+-- Ethernet1 VLAN2
+
+eth1VLAN2ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 ID"
+ ::= { eth1VLAN2 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.1
+
+eth1VLAN2Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 priority"
+ ::= { eth1VLAN2 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.2
+
+eth1VLAN2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 IP address"
+ ::= { eth1VLAN2 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.3
+
+eth1VLAN2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 subnet mask"
+ ::= { eth1VLAN2 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.4
+
+eth1VLAN2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN2 router"
+ ::= { eth1VLAN2 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.2.5
+
+-- Ethernet1 VLAN3
+
+eth1VLAN3ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 ID"
+ ::= { eth1VLAN3 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.1
+
+eth1VLAN3Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 priority"
+ ::= { eth1VLAN3 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.2
+
+eth1VLAN3Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 IP address"
+ ::= { eth1VLAN3 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.3
+
+eth1VLAN3SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 subnet mask"
+ ::= { eth1VLAN3 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.4
+
+eth1VLAN3Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN3 router"
+ ::= { eth1VLAN3 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.3.5
+
+-- Ethernet1 VLAN4
+
+eth1VLAN4ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 ID"
+ ::= { eth1VLAN4 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.1
+
+eth1VLAN4Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 priority"
+ ::= { eth1VLAN4 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.2
+
+eth1VLAN4Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 IP address"
+ ::= { eth1VLAN4 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.3
+
+eth1VLAN4SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 subnet mask"
+ ::= { eth1VLAN4 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.4
+
+eth1VLAN4Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN4 router"
+ ::= { eth1VLAN4 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.4.5
+
+-- Ethernet1 VLAN5
+
+eth1VLAN5ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 ID"
+ ::= { eth1VLAN5 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.1
+
+eth1VLAN5Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 priority"
+ ::= { eth1VLAN5 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.2
+
+eth1VLAN5Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 IP address"
+ ::= { eth1VLAN5 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.3
+
+eth1VLAN5SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 subnet mask"
+ ::= { eth1VLAN5 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.4
+
+eth1VLAN5Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN5 router"
+ ::= { eth1VLAN5 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.5.5
+
+-- Ethernet1 VLAN6
+
+eth1VLAN6ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 ID"
+ ::= { eth1VLAN6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.1
+
+eth1VLAN6Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 priority"
+ ::= { eth1VLAN6 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.2
+
+eth1VLAN6Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 IP address"
+ ::= { eth1VLAN6 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.3
+
+eth1VLAN6SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 subnet mask"
+ ::= { eth1VLAN6 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.4
+
+eth1VLAN6Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 VLAN6 router"
+ ::= { eth1VLAN6 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.5.6.5
+
+eth1MAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet1 MAC"
+ ::= { ethernet1 6 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.6
+
+eth1IPv6Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls IPv6 operation for this Ethernet interface."
+ ::= { eth1IPv6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.1
+
+eth1IPv6StaticAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "he static IPv6 address to use for this interface when in
+ operating in STATIC mode."
+ ::= { eth1IPv6Static 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.2.1
+
+eth1IPv6StaticRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 router to engage as the default router when this
+ interface operates in STATIC mode."
+ ::= { eth1IPv6Static 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.2.1
+
+eth1IPv6AutoAddress1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.3.1
+
+eth1IPv6AutoAddress2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.3.2
+
+eth1IPv6AutoAddress3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.3.3
+
+eth1IPv6AutoAddress4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth1IPv6Auto 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.3.4
+
+eth1IPv6LinkLocalAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link local IPv6 address for this interface. This is
+ present when the IPv6 mode is not OFF."
+ ::= { eth1IPv6 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.1.7.4
+
+
+eth2Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of the Ethernet2 interface: STATIC,DHCP,VLAN"
+ ::= { ethernet2 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.1
+
+eth2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 IP address"
+ ::= { ethernet2 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.2
+
+eth2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 subnet mask"
+ ::= { ethernet2 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.3
+
+eth2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 router"
+ ::= { ethernet2 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.4
+
+
+-- Ethernet2 VLAN1
+
+eth2VLAN1ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 ID"
+ ::= { eth2VLAN1 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.1
+
+eth2VLAN1Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 priority"
+ ::= { eth2VLAN1 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.2
+
+eth2VLAN1Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 IP address"
+ ::= { eth2VLAN1 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.3
+
+eth2VLAN1SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 subnet mask"
+ ::= { eth2VLAN1 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.4
+
+eth2VLAN1Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN1 router"
+ ::= { eth2VLAN1 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.1.5
+
+-- Ethernet2 VLAN2
+
+eth2VLAN2ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 ID"
+ ::= { eth2VLAN2 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.1
+
+eth2VLAN2Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 priority"
+ ::= { eth2VLAN2 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.2
+
+eth2VLAN2Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 IP address"
+ ::= { eth2VLAN2 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.3
+
+eth2VLAN2SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 subnet mask"
+ ::= { eth2VLAN2 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.4
+
+eth2VLAN2Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN2 router"
+ ::= { eth2VLAN2 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.2.5
+
+-- Ethernet2 VLAN3
+
+eth2VLAN3ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 ID"
+ ::= { eth2VLAN3 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.1
+
+eth2VLAN3Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 priority"
+ ::= { eth2VLAN3 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.2
+
+eth2VLAN3Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 IP address"
+ ::= { eth2VLAN3 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.3
+
+eth2VLAN3SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 subnet mask"
+ ::= { eth2VLAN3 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.4
+
+eth2VLAN3Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN3 router"
+ ::= { eth2VLAN3 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.3.5
+
+-- Ethernet2 VLAN4
+
+eth2VLAN4ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 ID"
+ ::= { eth2VLAN4 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.1
+
+eth2VLAN4Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 priority"
+ ::= { eth2VLAN4 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.2
+
+eth2VLAN4Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 IP address"
+ ::= { eth2VLAN4 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.3
+
+eth2VLAN4SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 subnet mask"
+ ::= { eth2VLAN4 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.4
+
+eth2VLAN4Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN4 router"
+ ::= { eth2VLAN4 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.4.5
+
+-- Ethernet2 VLAN5
+
+eth2VLAN5ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 ID"
+ ::= { eth2VLAN5 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.1
+
+eth2VLAN5Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 priority"
+ ::= { eth2VLAN5 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.2
+
+eth2VLAN5Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 IP address"
+ ::= { eth2VLAN5 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.3
+
+eth2VLAN5SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 subnet mask"
+ ::= { eth2VLAN5 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.4
+
+eth2VLAN5Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN5 router"
+ ::= { eth2VLAN5 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.5.5
+
+-- Ethernet2 VLAN6
+
+eth2VLAN6ID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 ID"
+ ::= { eth2VLAN6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.1
+
+eth2VLAN6Priority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 priority"
+ ::= { eth2VLAN6 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.2
+
+eth2VLAN6Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 IP address"
+ ::= { eth2VLAN6 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.3
+
+eth2VLAN6SubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 subnet mask"
+ ::= { eth2VLAN6 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.4
+
+eth2VLAN6Router OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 VLAN6 router"
+ ::= { eth2VLAN6 5 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.5.6.5
+
+eth2MAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet2 MAC"
+ ::= { ethernet2 6 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.6
+
+eth2IPv6Mode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls IPv6 operation for this Ethernet interface."
+ ::= { eth2IPv6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.1
+
+eth2IPv6StaticAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "he static IPv6 address to use for this interface when in
+ operating in STATIC mode."
+ ::= { eth2IPv6Static 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.2.1
+
+eth2IPv6StaticRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 router to engage as the default router when this
+ interface operates in STATIC mode."
+ ::= { eth2IPv6Static 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.2.1
+
+eth2IPv6AutoAddress1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 1 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.3.1
+
+eth2IPv6AutoAddress2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 2 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.3.2
+
+eth2IPv6AutoAddress3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 3 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.3.3
+
+eth2IPv6AutoAddress4 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One of the automatically-acquired IPv6 addresses."
+ ::= { eth2IPv6Auto 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.3.4
+
+eth2IPv6LinkLocalAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link local IPv6 address for this interface. This is
+ present when the IPv6 mode is not OFF."
+ ::= { eth2IPv6 4 }
+ --1.3.6.1.4.1.3052.14.2.4.1.1.2.7.4
+
+
+defaultRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default router/gateway"
+ ::= { network 2 }
+ --1.3.6.1.4.1.3052.14.2.4.2
+
+-- DNS
+
+dnsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DNSConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DNS server address table"
+ ::= { network 3 }
+ --1.3.6.1.4.1.3052.14.2.4.3
+
+dnsEntry OBJECT-TYPE
+ SYNTAX DNSConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DNS server address entry"
+ INDEX { dnsIndex }
+ ::= { dnsTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.3.1
+
+dnsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for DNS server address"
+ ::= { dnsEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.3.1.1
+
+dnsAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DNS server address"
+ ::= { dnsEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.3.1.2
+
+hostname OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hostname of the unit"
+ ::= { network 4 }
+ --1.3.6.1.4.1.3052.14.2.4.4
+
+hostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Static host table"
+ ::= { network 5 }
+ --1.3.6.1.4.1.3052.14.2.4.5
+
+hostEntry OBJECT-TYPE
+ SYNTAX HostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Static host entry"
+ INDEX { hostIndex }
+ ::= { hostTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.5.1
+
+hostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for static host"
+ ::= { hostEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.5.1.1
+
+hostDeclaration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Static host declaration string (i.e. 'address hostname')"
+ ::= { hostEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.5.1.2
+
+-- Network Command Processor
+
+ncpDuplex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "For network command processor: 1=Input characters are echoed; 0=no echo."
+ ::= { network 6 }
+ --1.3.6.1.4.1.3052.14.2.4.6
+
+ncpTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Network command processor inactivity timeout"
+ ::= { network 7 }
+ --1.3.6.1.4.1.3052.14.2.4.7
+
+-- SNMP
+
+snmpAgentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for snmp agent"
+ ::= { snmp 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.1
+
+snmpNotificationCaptureEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit receives and stores SNMP traps/informs"
+ ::= { snmp 5 }
+ --1.3.6.1.4.1.3052.14.2.4.8.5
+
+snmpNotificationCaptureFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "File to which unit stores received SNMP traps/informs"
+ ::= { snmp 6 }
+ --1.3.6.1.4.1.3052.14.2.4.8.6
+
+snmpNtfnAttempts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum of times the unit attempts to send a notification
+ (trap/inform) in 1 cycle"
+ ::= { snmpNotificationTx 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7.1
+
+snmpNtfnTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds between retries of sending a notification"
+ ::= { snmpNotificationTx 2 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7.2
+
+snmpNtfnCycles OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of times the unit attempts a group of attempts to send
+ a notification (a cycle)"
+ ::= { snmpNotificationTx 3 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7.3
+
+snmpNtfnSnooze OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes between cycles"
+ ::= { snmpNotificationTx 4 }
+ --1.3.6.1.4.1.3052.14.2.4.8.7.4
+
+
+-- SNMP Poll
+
+snmpPMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Mode of poll operation: OFF, POLL ONLY (just make the results
+ available to view), or POLL BUFFER (store the results)."
+ ::= { snmpPoll 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.1
+
+snmpPBufferFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CRDB file in which data is stored."
+ ::= { snmpPoll 2 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.2
+
+snmpPBufferAllPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Period (in seconds) that, if non-zero, all results are buffered
+ in the CRDB regardless of the threshold."
+ ::= { snmpPoll 3 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.3
+
+snmpPRequestTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SNMPPollRequestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of SNMP Poll requests."
+ ::= { snmpPoll 4 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4
+
+snmpPRequestEntry OBJECT-TYPE
+ SYNTAX SNMPPollRequestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table pf SNMP Poll requests."
+ INDEX { snmpPRequestIndex }
+ ::= { snmpPRequestTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1
+
+snmpPRequestIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of SNMP Poll requests."
+ ::= { snmpPRequestEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.1
+
+snmpPRequestDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A description for this single telemetry request; no functional effect."
+ ::= { snmpPRequestEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.2
+
+snmpPRequestAgent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP Agent IP address or hostname for this single telemetry request."
+ ::= { snmpPRequestEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.3
+
+snmpPRequestReadcom OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP read community for this single telemetry request."
+ ::= { snmpPRequestEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.4
+
+snmpPRequestOID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP object identifier for this single telemetry request."
+ ::= { snmpPRequestEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.5
+
+snmpPRequestPeriod OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How many seconds between periodic SNMP polls of this
+ single telemetry request."
+ ::= { snmpPRequestEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.6
+
+snmpPRequestID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A textual field that is part of the record containing
+ the telemetry result."
+ ::= { snmpPRequestEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.7
+
+snmpPRequestThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls when new data is stored upon a successful
+ telemetry request."
+ ::= { snmpPRequestEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.8
+
+snmpPRequestResultStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of the last attempt for this telemetry request."
+ ::= { snmpPRequestEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.10
+
+snmpPRequestResultValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The telemetry value if the last request was successful."
+ ::= { snmpPRequestEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.11
+
+snmpPRequestResultTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp of the last telemetry request."
+ ::= { snmpPRequestEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.12
+
+snmpPRequestResultType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the telemetry as reported by the agent."
+ ::= { snmpPRequestEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.4.8.9.4.1.13
+
+
+-- FTP
+
+ftpPushEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable FTP push for REGULAR (protocol: FTP) or SECURE (protocol:
+ SFTP) operation, or disable it (OFF)"
+ ::= { ftpPush 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.1
+
+ftpPushServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP server to which data should be pushed"
+ ::= { ftpPush 2 }
+ --1.3.6.1.4.1.3052.14.2.4.9.2
+
+ftpPushAccount OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP push account"
+ ::= { ftpPush 5 }
+ --1.3.6.1.4.1.3052.14.2.4.9.5
+
+ftpPushDirectory OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "FTP push directory"
+ ::= { ftpPush 6 }
+ --1.3.6.1.4.1.3052.14.2.4.9.6
+
+ftpPushperiod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes between pushes"
+ ::= { ftpPush 7 }
+ --1.3.6.1.4.1.3052.14.2.4.9.7
+
+ftpPushPushFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FTPPushPushFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of files to push"
+ ::= { ftpPush 8 }
+ --1.3.6.1.4.1.3052.14.2.4.9.8
+
+ftpPushPushFileEntry OBJECT-TYPE
+ SYNTAX FTPPushPushFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of files to push"
+ INDEX { ftpPushPushFileIndex }
+ ::= { ftpPushPushFileTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.8.1
+
+ftpPushPushFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of files to push"
+ ::= { ftpPushPushFileEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.8.1.1
+
+ftpPushPushFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push this local FILEx"
+ ::= { ftpPushPushFileEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.9.8.1.2
+
+ftpPushPushAudit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push the audit log"
+ ::= { ftpPush 9 }
+ --1.3.6.1.4.1.3052.14.2.4.9.9
+
+ftpPushPushAlarms OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF push the alarms/events file"
+ ::= { ftpPush 10 }
+ --1.3.6.1.4.1.3052.14.2.4.9.10
+
+ftpPushRemoteFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FTPPushRemoteFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of remote names of files to push"
+ ::= { ftpPush 11 }
+ --1.3.6.1.4.1.3052.14.2.4.9.11
+
+ftpPushRemoteFileEntry OBJECT-TYPE
+ SYNTAX FTPPushRemoteFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of remote names of files to push"
+ INDEX { ftpPushRemoteFileIndex }
+ ::= { ftpPushRemoteFileTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.11.1
+
+ftpPushRemoteFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of remote names of files to push"
+ ::= { ftpPushRemoteFileEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.9.11.1
+
+ftpPushRemoteFileName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "remote name of pushed FILEx (name on server)"
+ ::= { ftpPushRemoteFileEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.9.11.2
+
+ftpPushRemoteAlarmName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filename on server for alarms"
+ ::= { ftpPush 12 }
+ --1.3.6.1.4.1.3052.14.2.4.9.12
+
+ftpPushPassive OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF use ftp passive mode"
+ ::= { ftpPush 13 }
+ --1.3.6.1.4.1.3052.14.2.4.9.13
+
+ftpPushIncludeDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include the date in the name of the pushed file"
+ ::= { ftpPush 14 }
+ --1.3.6.1.4.1.3052.14.2.4.9.14
+
+ftpPushIncludeTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include the time in the name of the pushed file"
+ ::= { ftpPush 15 }
+ --1.3.6.1.4.1.3052.14.2.4.9.15
+
+ftpPushIncludeSeq OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include a sequence number in the name of the pushed file"
+ ::= { ftpPush 16 }
+ --1.3.6.1.4.1.3052.14.2.4.9.16
+
+ftpPushPermissions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Unix permissions to apply to pushed files (octal notation)."
+ ::= { ftpPush 17 }
+ --1.3.6.1.4.1.3052.14.2.4.9.17
+
+
+pppDialEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF PPP dialout enabled"
+ ::= { pppDial 1 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.1
+
+pppDialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "phone number to dial"
+ ::= { pppDial 2 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.2
+
+pppDialIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds of inactivity after which the unit disconnects"
+ ::= { pppDial 5 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.5
+
+pppDialRetries OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of dialing retries for PPP"
+ ::= { pppDial 6 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.6
+
+pppDialCDTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds to wait after dialing for CD before
+ giving up"
+ ::= { pppDial 7 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.7
+
+pppDialLoginTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait to negotiate PPP after connecting"
+ ::= { pppDial 8 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.8
+
+pppDialMdmInit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem init string to use when dialing PPP"
+ ::= { pppDial 9 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.9
+
+pppDialSuggestIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address to suggest as the unit's end (local end) of the
+ PPP link"
+ ::= { pppDial 10 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.10
+
+pppDialPlainLogin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF look for login/password prompt before negotiating
+ PPP"
+ ::= { pppDial 11 }
+ --1.3.6.1.4.1.3052.14.2.4.10.1.11
+
+pppHostEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Unit accepts PPP negotiation"
+ ::= { pppHost 1 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2.1
+
+pppHostIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds of inactivity after which PPP-hosted link will
+ terminate"
+ ::= { pppHost 2 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2.2
+
+pppHostLocalIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Local IP address to negotiate"
+ ::= { pppHost 3 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2.3
+
+pppHostRemoteIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote IP address to hand out to PPP peer"
+ ::= { pppHost 4 }
+ --1.3.6.1.4.1.3052.14.2.4.10.2.4
+
+-- Routing
+
+pppRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit routes IP traffic from PPP/Wireless to Ethernet"
+ ::= { routing 1 }
+ --1.3.6.1.4.1.3052.14.2.4.11.1
+
+ethRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit routes IP traffic from Ethernet to PPP/Wireless"
+ ::= { routing 2 }
+ --1.3.6.1.4.1.3052.14.2.4.11.2
+
+ethRoutingNATEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF unit applies NAT on routed IP frames egressing the
+ unit on its PPP interface"
+ ::= { routing 3 }
+ --1.3.6.1.4.1.3052.14.2.4.11.3
+
+routingInterface OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When Ethernet routing is enabled (routing.1), this is the
+ Ethernet interface to which IP frames received on PPP are
+ routed"
+ ::= { routing 4 }
+ --1.3.6.1.4.1.3052.14.2.4.11.4
+
+eth2WanRoutingEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Make ETH2 operate as a WAN port to route outbound traffic
+ arriving on ETH1."
+ ::= { routing 5 }
+ --1.3.6.1.4.1.3052.14.2.4.11.5
+
+-- IP Restrictions
+
+ipRestrictionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IPRestrictionConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of IP restrictions"
+ ::= { ipRestriction 1 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1
+
+ipRestrictionEntry OBJECT-TYPE
+ SYNTAX IPRestrictionConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of IP restrictions"
+ INDEX { ipRestrictionIndex }
+ ::= { ipRestrictionTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1
+
+ipRestrictionIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of IP restrictions"
+ ::= { ipRestrictionEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1.1.1
+
+ipRestrictionEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this IP restriction"
+ ::= { ipRestrictionEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1.1.2
+
+ipRestrictionMask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP restriction mask"
+ ::= { ipRestrictionEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.4.12.1.1.1.3
+
+
+-- RTS
+
+
+rtsFileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RTSFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of RTS files"
+ ::= { rts 1 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1
+
+rtsFileEntry OBJECT-TYPE
+ SYNTAX RTSFileConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of RTS files"
+ INDEX { rtsFileIndex }
+ ::= { rtsFileTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1
+
+rtsFileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of RTS files"
+ ::= { rtsFileEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.1
+
+rtsFileMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RTS mode (OFF,LISTEN,PUSH) for FILEx"
+ ::= { rtsFileEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.2
+
+rtsFileShowAnswer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Show answer string upon RTS connect for FILEx"
+ ::= { rtsFileEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.3
+
+rtsFileReqXON OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF require XON to start flow for FILEx"
+ ::= { rtsFileEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.4
+
+rtsFileTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Idle connection close timer (0 means no timeout) for FILEx"
+ ::= { rtsFileEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.5
+
+rtsFileEmptyClose OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF close the socket when FILEx is empty"
+ ::= { rtsFileEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.6
+
+rtsFilePushHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Host to which FILEx should be pushed via RTS"
+ ::= { rtsFileEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.7
+
+rtsFilePushPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port to which FILEx should be pushed via RTS"
+ ::= { rtsFileEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.8
+
+rtsFilePushRetryTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Retry timer (seconds) for retrying failed RTS push connect
+ attempts"
+ ::= { rtsFileEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.4.13.1.1.9
+
+-- RTS Alarms
+
+rtsAlarmsMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RTS mode (OFF,LISTEN,PUSH) for alarms file"
+ ::= { rtsAlarms 1 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.1
+
+rtsAlarmsShowAnswer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Show answer string upon RTS connect for alarms file"
+ ::= { rtsAlarms 2 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.2
+
+rtsAlarmsReqXON OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF require XON to start flow for alarms file"
+ ::= { rtsAlarms 3 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.3
+
+rtsAlarmsTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Idle connection close timer (0 means no timeout) for alarms
+ file"
+ ::= { rtsAlarms 4 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.4
+
+rtsAlarmsEmptyClose OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF close the socket when this file is empty for alarms
+ file"
+ ::= { rtsAlarms 5 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.5
+
+rtsAlarmsPushHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Host to which alarms file should be pushed via RTS"
+ ::= { rtsAlarms 6 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.6
+
+rtsAlarmsPushPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port to which alarms file should be pushed via RTS"
+ ::= { rtsAlarms 7 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.7
+
+rtsAlarmsPushRetryTimer OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Retry timer (seconds) for retrying failed RTS push connect
+ attempts"
+ ::= { rtsAlarms 8 }
+ --1.3.6.1.4.1.3052.14.2.4.13.2.8
+
+-- Traps
+
+trapIncludeDateTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include date and time in stock trap message"
+ ::= { trapInclude 1 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.1
+
+trapIncludeSiteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include site name in stock trap message"
+ ::= { trapInclude 2 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.2
+
+trapIncludeSensorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include sensor ID in stock trap message"
+ ::= { trapInclude 3 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.3
+
+trapIncludeUDName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include user defined name in stock trap message"
+ ::= { trapInclude 4 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.4
+
+trapIncludeUDState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include user defined state in stock trap message"
+ ::= { trapInclude 5 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.5
+
+trapIncludeSourceAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF include source IP address in stock trap message"
+ ::= { trapInclude 6 }
+ --1.3.6.1.4.1.3052.14.2.4.14.1.6
+
+trapAuthFailEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable trap sent upon SNMP authentication failure"
+ ::= { trap 2 }
+ --1.3.6.1.4.1.3052.14.2.4.14.2
+
+-- Route testing
+
+routeTestEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable route testing"
+ ::= { routeTest 1 }
+ --1.3.6.1.4.1.3052.14.2.4.15.1
+
+
+routeTestPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The period which a route is considered valid"
+ ::= { routeTest 2 }
+ --1.3.6.1.4.1.3052.14.2.4.15.2
+
+routeTestAddressTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RouteTestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of route testing addresses"
+ ::= { routeTest 3 }
+ --1.3.6.1.4.1.3052.14.2.4.15.3
+
+routeTestAddressEntry OBJECT-TYPE
+ SYNTAX RouteTestConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of RTS files"
+ INDEX { routeTestAddressIndex }
+ ::= { routeTestAddressTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.15.3.1
+
+routeTestAddressIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of RTS files"
+ ::= { routeTestAddressEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.15.3.1.1
+
+routeTestAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Address to ping to see if the route to it is valid"
+ ::= { routeTestAddressEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.15.3.1.2
+
+
+-- Wireless
+
+
+wirelessMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless mode (OFF,PERMANENT-EDGE)"
+ ::= { wireless 1 }
+ --1.3.6.1.4.1.3052.14.2.4.16.1
+
+wirelessAPN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless access point name"
+ ::= { wireless 2 }
+ --1.3.6.1.4.1.3052.14.2.4.16.2
+
+wirelessIdleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless idle timeout"
+ ::= { wireless 3 }
+ --1.3.6.1.4.1.3052.14.2.4.16.3
+
+wirelessDRE OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Default route enable for wireless network interface.
+ When this is ON, the wireless link, if up, becomes
+ the default route, overriding the default route setting
+ (defaultRouter object). When OFF, the default route
+ setting controls the default route and the wireless link
+ does not become the default route."
+ ::= { wireless 9 }
+ --1.3.6.1.4.1.3052.14.2.4.16.9
+
+wirelessPPPUsername OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Username for PPP-based wireless modem connections."
+ ::= { wireless 10 }
+ --1.3.6.1.4.1.3052.14.2.4.16.10
+
+wirelessFirewall OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem firewall."
+ ::= { wireless 11 }
+ --1.3.6.1.4.1.3052.14.2.4.16.11
+
+wirelessKeepaliveThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes of no RX activity before sending keep-alive."
+ ::= { wireless 12 }
+ --1.3.6.1.4.1.3052.14.2.4.16.12
+
+wirelessPPPDebug OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem PPP debug."
+ ::= { wireless 13 }
+ --1.3.6.1.4.1.3052.14.2.4.16.13
+
+wirelessConnEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable wireless modem connectivity check."
+ ::= { wirelessConnectivity 1 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.1
+
+wirelessConnCheckInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check interval in minutes."
+ ::= { wirelessConnectivity 2 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.2
+
+wirelessConnFailThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity fail threshold."
+ ::= { wirelessConnectivity 3 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.3
+
+wirelessConnIP1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check IP address 1."
+ ::= { wirelessConnectivity 10 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.10
+
+wirelessConnIP2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Wireless connectivity check IP address 2."
+ ::= { wirelessConnectivity 11 }
+ --1.3.6.1.4.1.3052.14.2.4.16.20.11
+
+
+-- Email
+
+
+emailServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SMTP server to which the unit sends email"
+ ::= { email 1 }
+ --1.3.6.1.4.1.3052.14.2.4.17.1
+
+emailDomain OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Domain to use in recipient address"
+ ::= { email 2 }
+ --1.3.6.1.4.1.3052.14.2.4.17.2
+
+emailAuthEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable SMTP authentication"
+ ::= { email 3 }
+ --1.3.6.1.4.1.3052.14.2.4.17.3
+
+-- Advanced network config
+
+arpFilter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ARP filter code"
+ ::= { netAdvanced 1 }
+ --1.3.6.1.4.1.3052.14.2.4.18.1
+
+
+-- Web interface
+
+webEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF for the web interface"
+ ::= { web 1 }
+ --1.3.6.1.4.1.3052.14.2.4.19.1
+
+webPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which web interface listens"
+ ::= { web 2 }
+ --1.3.6.1.4.1.3052.14.2.4.19.2
+
+webTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Web interface session timeout (seconds)"
+ ::= { web 3 }
+ --1.3.6.1.4.1.3052.14.2.4.19.3
+
+
+
+-- IPv6
+
+ipv6DefaultRouter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv6 default router in use."
+ ::= { ipv6 1 }
+ --1.3.6.1.4.1.3052.14.2.4.21.1
+
+
+
+-- CPE table
+
+cpeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CPEConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CPEs"
+ ::= { cpe 1 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1
+
+cpeEntry OBJECT-TYPE
+ SYNTAX CPEConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CPEs"
+ INDEX { cpeIndex }
+ ::= { cpeTable 1 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1
+
+cpeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CPEs"
+ ::= { cpeEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.1
+
+cpeHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE host (IP address or DNS name)"
+ ::= { cpeEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.2
+
+cpeName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE name, informational only"
+ ::= { cpeEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.3
+
+cpeDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE description, informational only"
+ ::= { cpeEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.4
+
+cpeKeepalive OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds between each successful ping request."
+ ::= { cpeEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.5
+
+cpeThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of unsuccessful pings that triggers the CPE event."
+ ::= { cpeEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.6
+
+cpeEventReminderInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE event reminder interval (minutes)."
+ ::= { cpeEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.7
+
+cpeKeepaliveTicks OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "CPE ping period in 16ths of a second (nonzero overrides keepalive)."
+ ::= { cpeEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.20
+
+cpePingSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of bytes in CPE ping payload"
+ ::= { cpeEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.11
+
+cpeInfoReset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Set any number to reset CPE ping stats."
+ ::= { cpeEntry 30 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.30
+
+cpeInfoNumReq OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of requests transmitted."
+ ::= { cpeEntry 31 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.31
+
+cpeInfoNumGoodResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of non-corrupt responses."
+ ::= { cpeEntry 32 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.32
+
+cpeInfoNumBadResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of corrupt responses."
+ ::= { cpeEntry 33 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.33
+
+cpeInfoNumLostResp OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of requests with no response."
+ ::= { cpeEntry 34 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.34
+
+cpeInfoPercentLoss OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent loss (missing responses / total requests)."
+ ::= { cpeEntry 35 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.35
+
+cpeInfoPercentBad OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent corrupt (corrupt responses / total requests)."
+ ::= { cpeEntry 36 }
+ --1.3.6.1.4.1.3052.14.2.4.22.1.1.36
+
+--***************************************************************************************
+--Modem Section 2.5
+--***************************************************************************************
+
+
+
+
+
+modemFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem data format (8N1,7E1,7O1,7N1)"
+ ::= { modem 1 }
+ --1.3.6.1.4.1.3052.14.2.5.1
+
+modemInitString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Init string for modem"
+ ::= { modem 2 }
+ --1.3.6.1.4.1.3052.14.2.5.2
+
+
+modemCallAttempts OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Max mumber of times the modem should try to call out until
+ successful connect"
+ ::= { modem 4 }
+ --1.3.6.1.4.1.3052.14.2.5.4
+
+modemCallDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum delay (seconds) between callouts"
+ ::= { modem 5 }
+ --1.3.6.1.4.1.3052.14.2.5.6
+
+
+modemCmdTimout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of minutes after which an idle command session via
+ modem is terminated"
+ ::= { modem 6 }
+ --1.3.6.1.4.1.3052.14.2.5.6
+
+modemGoto OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When a user connects, where that user is routed (command
+ session, passthrough to port 1, passthrough to port 2, etc.)"
+ ::= { modem 7 }
+ --1.3.6.1.4.1.3052.14.2.5.7
+
+
+modemCLIDEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Calling Line Identification security"
+ ::= { modemClid 1 }
+ --1.3.6.1.4.1.3052.14.2.5.8.1
+
+
+modemCLIDNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ModemCLIDNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of authorized callers identified by phone number"
+ ::= { modemClid 2 }
+ --1.3.6.1.4.1.3052.14.2.5.8.2
+
+modemCLIDNumberEntry OBJECT-TYPE
+ SYNTAX ModemCLIDNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CLID numbers"
+ INDEX { modemCLIDNumberIndex }
+ ::= { modemCLIDNumberTable 1 }
+ --1.3.6.1.4.1.3052.14.2.5.8.2.1
+
+modemCLIDNumberIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CLID numbers"
+ ::= { modemCLIDNumberEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.5.8.2.1.1
+
+modemCLIDNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "auhorized CLID number"
+ ::= { modemCLIDNumberEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.5.8.2.1.2
+
+modemTAPInitString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Init string to use for TAP (pager) connections"
+ ::= { modem 9 }
+ --1.3.6.1.4.1.3052.14.2.5.9
+
+modemTAP8N1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: use 8N1 data/parity/stop for TAP connections"
+ ::= { modem 10 }
+ --1.3.6.1.4.1.3052.14.2.5.10
+
+
+--***************************************************************************************
+--Time Section 2.8
+--***************************************************************************************
+
+clock OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Text string for date and time;
+ e.g. 'SUN 01/02/98 12:34:27'. When setting
+ this object, only the date and time are
+ required; the unit will ignore a specified
+ day of week because it is calculated from
+ the date and time. When this object is included
+ in a notification as a varbind, it represents
+ the time that the triggering event occurred."
+ ::= { time 1 }
+ --1.3.6.1.4.1.3052.14.2.8.1
+
+--***************************************************************************************
+--Console Section 2.10
+--***************************************************************************************
+
+
+consoleDuplex OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF characters echoed on telnet command session"
+ ::= { console 1 }
+ --1.3.6.1.4.1.3052.14.2.10.1
+
+consoleTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minutes of inactivity after which telnet command session is terminated"
+ ::= { console 2 }
+ --1.3.6.1.4.1.3052.14.2.10.2
+
+consoleBaud OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console baud rate"
+ ::= { console 4 }
+ --1.3.6.1.4.1.3052.14.2.10.4
+
+consoleFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console data format (8N1,7E1,7O1,7N1,8O2)"
+ ::= { console 5 }
+ --1.3.6.1.4.1.3052.14.2.10.5
+
+consoleHsk OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console handshaking mode"
+ ::= { console 6 }
+ --1.3.6.1.4.1.3052.14.2.10.6
+
+consoleConfirm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Prompt to confirm certain actions"
+ ::= { console 7 }
+ --1.3.6.1.4.1.3052.14.2.10.7
+
+--***************************************************************************************
+--Core Security Section 2.11.1
+--***************************************************************************************
+
+scShowPasswordPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF show password prompt upon login"
+ ::= { secCore 1 }
+ --1.3.6.1.4.1.3052.14.2.11.1.1
+
+scConsoleLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via console"
+ ::= { secCore 2 }
+ --1.3.6.1.4.1.3052.14.2.11.1.2
+
+scModemLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via modem"
+ ::= { secCore 3 }
+ --1.3.6.1.4.1.3052.14.2.11.1.3
+
+scTelnetLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via Telnet"
+ ::= { secCore 4 }
+ --1.3.6.1.4.1.3052.14.2.11.1.4
+
+scTelnetPTLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting via Telnet to pass-
+ through ports (TCP ports 210x)"
+ ::= { secCore 5 }
+ --1.3.6.1.4.1.3052.14.2.11.1.5
+
+scRTSLoginRequired OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF login required upon connecting to RTS (TCP ports 220x)"
+ ::= { secCore 6 }
+ --1.3.6.1.4.1.3052.14.2.11.1.6
+
+scAuthMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Authentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)"
+ ::= { secCore 7 }
+ --1.3.6.1.4.1.3052.14.2.11.1.7
+
+scRightsGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The set of aliases used for the 8 available rights levels"
+ ::= { secCore 8 }
+ --1.3.6.1.4.1.3052.14.2.11.1.8
+
+
+--***************************************************************************************
+--User Security Section 2.11.2
+--***************************************************************************************
+
+
+secUserTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SecUserConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of users"
+ ::= { unitSecurity 2 }
+ --1.3.6.1.4.1.3052.14.2.11.2
+
+secUserEntry OBJECT-TYPE
+ SYNTAX SecUserConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of users"
+ INDEX { secUserIndex }
+ ::= { secUserTable 1 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1
+
+secUserIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of users"
+ ::= { secUserEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.1
+
+secUserEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable user"
+ ::= { secUserEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.2
+
+secUserConnectVia OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Methods by which user is allowed to connect:
+ L=local (console)
+ T=Telnet
+ M=modem
+ F=FTP
+ R=RTS
+ S=SSH
+ "
+ ::= { secUserEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.5
+
+secUserLoginTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The function presented to the user upon login (COMMAND,
+ PASSTHROUGH,MENU)"
+ ::= { secUserEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.6
+
+secUserAccessFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The default access file associated with the user"
+ ::= { secUserEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.7
+
+secUserPTEscapeTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The function presented to the user upon escaping pass-
+ through: currently only MENU"
+ ::= { secUserEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.9
+
+secUserPPPType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The kind of PPP access allowed to this user cannot connect
+ via PPP (NONE), can connect but only to the unit (LOCAL), or
+ can connect and route to Ethernet (ROUTING)"
+ ::= { secUserEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.10
+
+secUserRights OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The rights level granted to this user"
+ ::= { secUserEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.11
+
+secUserEventsReadAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to read the events/alarms file"
+ ::= { secUserEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.13
+
+secUserAuditReadAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to read the audit log"
+ ::= { secUserEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.14
+
+secUserEventsWriteAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to delete the events file"
+ ::= { secUserEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.16
+
+secUserAuditWriteAccess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DENY/ALLOW user to write to the audit log"
+ ::= { secUserEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.17
+
+secUserExpiration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Expiration date/time of this user"
+ ::= { secUserEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.18
+
+secUserCallbackNumber1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 1 the unit calls for dialback"
+ ::= { secUserEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.19
+
+secUserCallbackNumber2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 2 the unit calls for dialback"
+ ::= { secUserEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.20
+
+secUserCallbackNumber3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number slot 3 the unit calls for dialback"
+ ::= { secUserEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.21
+
+secUserChallengeTelnetMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Telnet challenge mode: when user logs in via telnet, unit
+ allows access (OFF), presents a challenge (CHALLENGE), or
+ unit sends a one-time-password (SEND PASSWORD) to a
+ destination configured by secUserChallengeTelnetSendTo"
+ ::= { secUserEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.22
+
+secUserChallengeModemMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem challenge mode: when user logs in via modem, unit
+ allows access (OFF), presents a challenge (CHALLENGE), sends
+ a one-time-password (SEND PASSWORD) to a destination
+ configured by secUserChallengeTelnetSendTo, or dials a
+ number (CALLBACK) configured with secUserCallbackNumberx"
+ ::= { secUserEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.23
+
+secUserChallengeConsoleMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Console challenge mode: when user logs in via console, unit
+ allows access (OFF), or presents a challenge (CHALLENGE)"
+ ::= { secUserEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.24
+
+secUserChallengeTelnetSendTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Email action used as the destination address for one-time-
+ password when a user logs in with a challenge mode of
+ SEND PASSWORD"
+ ::= { secUserEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.25
+
+secUserChallengeModemSendTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modem action used as the destination phone number for one-
+ time-password when a user logs in with a challenge mode of
+ SEND PASSWORD"
+ ::= { secUserEntry 26 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.26
+
+secUserChallengeExpiration OBJECT-TYPE
+ SYNTAX Integer32 (0..180)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time (in minutes) after which a one-time-password is sent
+ that it can be used to log in"
+ ::= { secUserEntry 27 }
+ --1.3.6.1.4.1.3052.14.2.11.2.1.27
+
+
+--***************************************************************************************
+--Factory Security Section 2.11.3
+--***************************************************************************************
+
+sfEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable factory access"
+ ::= { secFactory 1 }
+ --1.3.6.1.4.1.3052.14.2.11.3.1
+
+sfSecret OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Secret used for factory access"
+ ::= { secFactory 2 }
+ --1.3.6.1.4.1.3052.14.2.11.3.2
+
+
+--***************************************************************************************
+--SSH Security Section 2.11.3
+--***************************************************************************************
+
+--***************************************************************************************
+--Event Section 2.12
+--***************************************************************************************
+
+--***************************************************************************************
+--Event Core Section 2.12.1
+--***************************************************************************************
+
+
+evClassNameTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventClassConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of classes"
+ ::= { evCore 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1.1
+
+evClassNameEntry OBJECT-TYPE
+ SYNTAX EventClassConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of classes"
+ INDEX { evClassNameIndex }
+ ::= { evClassNameTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1.1.1
+
+evClassNameIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..12)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of classes"
+ ::= { evClassNameEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1.1.1.1
+
+evClassName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class name for this slot"
+ ::= { evClassNameEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.1.1.1.2
+
+evReminderInterval OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval (minutes) between EventSensor reminder events"
+ ::= { evCore 2 }
+ --1.3.6.1.4.1.3052.14.2.12.1.2
+
+evLogEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable event log"
+ ::= { evLog 1 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.1
+
+evLogStoreAlarm OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF store data alarms in event log"
+ ::= { evLog 2 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.2
+
+evLogMaxSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "max size (in KB) of event log"
+ ::= { evLog 3 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.3
+
+evLogStoreSensor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF store EventSensor events in event log"
+ ::= { evLog 4 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.4
+
+evLogTimeStampAlarms OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF put timestamps on event log entries"
+ ::= { evLog 5 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.5
+
+evLogPrependName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF prepend data event name to data alarm records in event
+ log"
+ ::= { evLog 6 }
+ --1.3.6.1.4.1.3052.14.2.12.1.3.6
+
+
+evMgmtReprocess OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of sensors that have generated events since reset.
+ Write this to reprocess each sensor's last generated event
+ since reset. The value to write determines what kind of
+ events should be reprocessed:
+ 'all': all sensor events
+ 'cc': cc events
+ 'temperature': temperature events
+ 'humidity': humidity events
+ 'analog': analog input events"
+ ::= { evMgmt 3 }
+ --1.3.6.1.4.1.3052.14.2.12.1.4.3
+
+
+
+
+
+
+--***************************************************************************************
+--Data event section 2.12.2
+--***************************************************************************************
+
+evdExitOnTrue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: Data alarm evaluator stops checking record against
+ alarm equations when it finds an equation that matches"
+ ::= { evdCore 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.1.1.1
+
+evdFilterAction OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "What happens to a record that matches an equation:
+ REJECT/ACCEPT"
+ ::= { evdCore 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.1.1.2
+
+evdWildCardChar OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Character (in decimal ASCII code format) used to indicate
+ wildcards in data alarm equation"
+ ::= { evdCore 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.1.1.3
+
+
+evdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data events"
+ ::= { evData 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2
+
+evdEntry OBJECT-TYPE
+ SYNTAX DataEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data events"
+ INDEX { evdIndex }
+ ::= { evdTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1
+
+evdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data events"
+ ::= { evdEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.1
+
+evdEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this data event"
+ ::= { evdEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.2
+
+evdName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for this data event"
+ ::= { evdEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.3
+
+evdEquation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Equation for this data event"
+ ::= { evdEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.4
+
+evdThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of equation matches that must happen to trigger this
+ data event"
+ ::= { evdEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.5
+
+evdAutoClear OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF this data alarm is automatically cleared (re-armed)
+ upon reaching the threshold number of matches"
+ ::= { evdEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.6
+
+evdClearInterval OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval at which this alarm is automatically cleared (no
+ bearing with evdAutoClear)"
+ ::= { evdEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.7
+
+evdClearTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tie of day (HH:MM) at which this data alarm is cleared (no
+ bearing with evdAutoClear)"
+ ::= { evdEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.8
+
+evdActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this data event"
+ ::= { evdEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.9
+
+evdClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this data event"
+ ::= { evdEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.10
+
+evdTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this event"
+ ::= { evdEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.11
+
+evdMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ALARM/FILTER: what is happens when this data event
+ triggers: either generate actions (mode=ALARM) )or
+ ACCEPT/REJECT (via evdFilterAction) the record
+ (mode=FILTER)"
+ ::= { evdEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.2.2.1.12
+
+evdFieldTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventFieldConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data event fields"
+ ::= { evData 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3
+
+evdFieldEntry OBJECT-TYPE
+ SYNTAX DataEventFieldConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data event fields"
+ INDEX { evdFieldIndex }
+ ::= { evdFieldTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1
+
+evdFieldIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data event fields"
+ ::= { evdFieldEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.1
+
+evdFieldStart OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start position (1-based) for this data event field"
+ ::= { evdFieldEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.2
+
+evdFieldLength OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of characters this data event field occupies"
+ ::= { evdFieldEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.3
+
+evdFieldName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start position (1-based) for this data event field"
+ ::= { evdFieldEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.4
+
+evdFieldLine OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Line number (1-based, for multiline records) for this data
+ event field"
+ ::= { evdFieldEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.5
+
+evdFieldType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Alpha/Numeric type for this data event field"
+ ::= { evdFieldEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.2.3.1.6
+
+evdMacroTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DataEventMacroConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of data event macros"
+ ::= { evData 4 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4
+
+evdMacroEntry OBJECT-TYPE
+ SYNTAX DataEventMacroConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of data event macros"
+ INDEX { evdMacroIndex }
+ ::= { evdMacroTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4.1
+
+evdMacroIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of data event macros"
+ ::= { evdMacroEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4.1.1
+
+evdMacroName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of this macro for use in data event equations"
+ ::= { evdMacroEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4.1.2
+
+evdMacroEquation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Equation for this data event macro"
+ ::= { evdMacroEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.2.4.1.3
+
+--***************************************************************************************
+--No data event 1 Section 2.12.3
+--***************************************************************************************
+
+evNoData1Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this no data event"
+ ::= { evNoData1 1 }
+ --1.3.6.1.4.1.3052.14.2.12.3.1
+
+evNoData1Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this no data event"
+ ::= { evNoData1 2 }
+ --1.3.6.1.4.1.3052.14.2.12.3.2
+
+evNoData1Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this no data event"
+ ::= { evNoData1 3 }
+ --1.3.6.1.4.1.3052.14.2.12.3.3
+
+evNoData1TrapNum OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this no data event"
+ ::= { evNoData1 4 }
+ --1.3.6.1.4.1.3052.14.2.12.3.4
+
+evNoData1Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this no data event"
+ ::= { evNoData1 5 }
+ --1.3.6.1.4.1.3052.14.2.12.3.5
+
+evNoData1Sched1Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 begin time (HH:MM) for this no data event"
+ ::= { evNoData1 6 }
+ --1.3.6.1.4.1.3052.14.2.12.3.6
+
+evNoData1Sched1End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 end time (HH:MM) for this no data event"
+ ::= { evNoData1 7 }
+ --1.3.6.1.4.1.3052.14.2.12.3.7
+
+evNoData1Sched1Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 1 of this no data event"
+ ::= { evNoData1 8 }
+ --1.3.6.1.4.1.3052.14.2.12.3.8
+
+evNoData1Sched2Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 begin time (HH:MM) for this no data event"
+ ::= { evNoData1 9 }
+ --1.3.6.1.4.1.3052.14.2.12.3.9
+
+evNoData1Sched2End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 end time (HH:MM) for this no data event"
+ ::= { evNoData1 10 }
+ --1.3.6.1.4.1.3052.14.2.12.3.10
+
+evNoData1Sched2Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 2 of this no data event"
+ ::= { evNoData1 11 }
+ --1.3.6.1.4.1.3052.14.2.12.3.11
+
+evNoData1PortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NoDataEvent1PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of no data event 1 port enables"
+ ::= { evNoData1 12 }
+ --1.3.6.1.4.1.3052.14.2.12.3.12
+
+evNoData1PortEnableEntry OBJECT-TYPE
+ SYNTAX NoDataEvent1PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of no data event 1 port enables"
+ INDEX { evNoData1PortEnableIndex }
+ ::= { evNoData1PortEnableTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.3.12.1
+
+evNoData1PortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of no data event 1 port enables"
+ ::= { evNoData1PortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.3.12.1.1
+
+evNoData1PortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: no data event 1 observes this port"
+ ::= { evNoData1PortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.3.12.1.2
+
+evNoData1Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ no data event"
+ ::= { evNoData1 13 }
+ --1.3.6.1.4.1.3052.14.2.12.3.13
+
+evNoData1Days OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Days of the week on which this no event is active"
+ ::= { evNoData1 14 }
+ --1.3.6.1.4.1.3052.14.2.12.3.14
+
+--***************************************************************************************
+--No data event 2 Section 2.12.4
+--***************************************************************************************
+
+evNoData2Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this no data event"
+ ::= { evNoData2 1 }
+ --1.3.6.1.4.1.3052.14.2.12.4.1
+
+evNoData2Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this no data event"
+ ::= { evNoData2 2 }
+ --1.3.6.1.4.1.3052.14.2.12.4.2
+
+evNoData2Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this no data event"
+ ::= { evNoData2 3 }
+ --1.3.6.1.4.1.3052.14.2.12.4.3
+
+evNoData2TrapNum OBJECT-TYPE
+ SYNTAX Integer32 (505..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this no data event"
+ ::= { evNoData2 4 }
+ --1.3.6.1.4.1.3052.14.2.12.4.4
+
+evNoData2Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this no data event"
+ ::= { evNoData2 5 }
+ --1.3.6.1.4.1.3052.14.2.12.4.5
+
+evNoData2Sched1Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 begin time (HH:MM) for this no data event"
+ ::= { evNoData2 6 }
+ --1.3.6.1.4.1.3052.14.2.12.4.6
+
+evNoData2Sched1End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 1 end time (HH:MM) for this no data event"
+ ::= { evNoData2 7 }
+ --1.3.6.1.4.1.3052.14.2.12.4.7
+
+evNoData2Sched1Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 1 of this no data event"
+ ::= { evNoData2 8 }
+ --1.3.6.1.4.1.3052.14.2.12.4.8
+
+evNoData2Sched2Begin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 begin time (HH:MM) for this no data event"
+ ::= { evNoData2 9 }
+ --1.3.6.1.4.1.3052.14.2.12.4.9
+
+evNoData2Sched2End OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Schedule 2 end time (HH:MM) for this no data event"
+ ::= { evNoData2 10 }
+ --1.3.6.1.4.1.3052.14.2.12.4.10
+
+evNoData2Sched2Duration OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Duration (minutes) for schedule 2 of this no data event"
+ ::= { evNoData2 11 }
+ --1.3.6.1.4.1.3052.14.2.12.4.11
+
+evNoData2PortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NoDataEvent2PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of no data event 2 port enables"
+ ::= { evNoData2 12 }
+ --1.3.6.1.4.1.3052.14.2.12.4.12
+
+evNoData2PortEnableEntry OBJECT-TYPE
+ SYNTAX NoDataEvent2PortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of no data event 2 port enables"
+ INDEX { evNoData2PortEnableIndex }
+ ::= { evNoData2PortEnableTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.4.12.1
+
+evNoData2PortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of no data event 2 port enables"
+ ::= { evNoData2PortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.4.12.1.1
+
+evNoData2PortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: no data event 2 observes this port"
+ ::= { evNoData2PortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.4.12.1.2
+
+evNoData2Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ no data event"
+ ::= { evNoData2 13 }
+ --1.3.6.1.4.1.3052.14.2.12.4.13
+
+evNoData2Days OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Days of the week on which this no event is active"
+ ::= { evNoData2 14 }
+ --1.3.6.1.4.1.3052.14.2.12.4.14
+
+--***************************************************************************************
+--Scheduled Event 1 Section 2.12.5
+--***************************************************************************************
+
+evSched1Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this scheduled event"
+ ::= { evSched1 1 }
+ --1.3.6.1.4.1.3052.14.2.12.5.1
+
+evSched1Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this scheduled event"
+ ::= { evSched1 2 }
+ --1.3.6.1.4.1.3052.14.2.12.5.2
+
+evSched1Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this scheduled event"
+ ::= { evSched1 3 }
+ --1.3.6.1.4.1.3052.14.2.12.5.3
+
+evSched1TrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this scheduled event"
+ ::= { evSched1 4 }
+ --1.3.6.1.4.1.3052.14.2.12.5.4
+
+evSched1Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this scheduled event"
+ ::= { evSched1 5 }
+ --1.3.6.1.4.1.3052.14.2.12.5.5
+
+evSched1Sunday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Sunday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 6 }
+ --1.3.6.1.4.1.3052.14.2.12.5.6
+
+evSched1Monday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Monday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 7 }
+ --1.3.6.1.4.1.3052.14.2.12.5.7
+
+evSched1Tuesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Tuesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 8 }
+ --1.3.6.1.4.1.3052.14.2.12.5.8
+
+evSched1Wednesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Wednesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 9 }
+ --1.3.6.1.4.1.3052.14.2.12.5.9
+
+evSched1Thursday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Thursday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 10 }
+ --1.3.6.1.4.1.3052.14.2.12.5.10
+
+evSched1Friday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Friday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 11 }
+ --1.3.6.1.4.1.3052.14.2.12.5.11
+
+evSched1Saturday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Saturday (HH:MM) when this scheduled event triggers"
+ ::= { evSched1 12 }
+ --1.3.6.1.4.1.3052.14.2.12.5.12
+
+evSched1Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ scheduled event"
+ ::= { evSched1 13 }
+ --1.3.6.1.4.1.3052.14.2.12.5.13
+
+
+--***************************************************************************************
+--Scheduled Event 2 Section 2.12.6
+--***************************************************************************************
+
+evSched2Enable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this scheduled event"
+ ::= { evSched2 1 }
+ --1.3.6.1.4.1.3052.14.2.12.6.1
+
+evSched2Actions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for this scheduled event"
+ ::= { evSched2 2 }
+ --1.3.6.1.4.1.3052.14.2.12.6.2
+
+evSched2Message OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for this scheduled event"
+ ::= { evSched2 3 }
+ --1.3.6.1.4.1.3052.14.2.12.6.3
+
+evSched2TrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for this scheduled event"
+ ::= { evSched2 4 }
+ --1.3.6.1.4.1.3052.14.2.12.6.4
+
+evSched2Class OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for this scheduled event"
+ ::= { evSched2 5 }
+ --1.3.6.1.4.1.3052.14.2.12.6.5
+
+evSched2Sunday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Sunday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 6 }
+ --1.3.6.1.4.1.3052.14.2.12.6.6
+
+evSched2Monday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Monday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 7 }
+ --1.3.6.1.4.1.3052.14.2.12.6.7
+
+evSched2Tuesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Tuesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 8 }
+ --1.3.6.1.4.1.3052.14.2.12.6.8
+
+evSched2Wednesday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Wednesday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 9 }
+ --1.3.6.1.4.1.3052.14.2.12.6.9
+
+evSched2Thursday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Thursday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 10 }
+ --1.3.6.1.4.1.3052.14.2.12.6.10
+
+evSched2Friday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Friday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 11 }
+ --1.3.6.1.4.1.3052.14.2.12.6.11
+
+evSched2Saturday OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time on Saturday (HH:MM) when this scheduled event triggers"
+ ::= { evSched2 12 }
+ --1.3.6.1.4.1.3052.14.2.12.6.12
+
+evSched2Exclusions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Exclusions (space-separated MM/DD-formatted dates) for this
+ scheduled event"
+ ::= { evSched2 13 }
+ --1.3.6.1.4.1.3052.14.2.12.6.13
+
+--***************************************************************************************
+--Serial Handshaking Low Section 2.12.7
+--***************************************************************************************
+
+evShskLowTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SerialHandshakingLowEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of serial handshaking low events"
+ ::= { event 7 }
+ --1.3.6.1.4.1.3052.14.2.12.7
+
+evShskLowEntry OBJECT-TYPE
+ SYNTAX SerialHandshakingLowEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of serial handshaking low events"
+ INDEX { evShskLowIndex }
+ ::= { evShskLowTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1
+
+evShskLowIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of serial handshaking low events"
+ ::= { evShskLowEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.1
+
+evShskLowEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enable the serial handshaking low event for this port"
+ ::= { evShskLowEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.2
+
+evShskLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.3
+
+evShskLowMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.4
+
+evShskLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.5
+
+evShskLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the serial handshaking low event for this port"
+ ::= { evShskLowEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.7.1.6
+
+
+--***************************************************************************************
+--Serial Handshaking High Section 2.12.8
+--***************************************************************************************
+
+evShskHighTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SerialHandshakingHighEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of serial handshaking high events"
+ ::= { event 8 }
+ --1.3.6.1.4.1.3052.14.2.12.8
+
+evShskHighEntry OBJECT-TYPE
+ SYNTAX SerialHandshakingHighEventConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of serial handshaking high events"
+ INDEX { evShskHighIndex }
+ ::= { evShskHighTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1
+
+evShskHighIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of serial handshaking high events"
+ ::= { evShskHighEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.1
+
+evShskHighEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enable the serial handshaking high event for this
+ port"
+ ::= { evShskHighEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.2
+
+evShskHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.3
+
+evShskHighMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.4
+
+evShskHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for the serial handshaking high event for this port"
+ ::= { evShskHighEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.5
+
+evShskHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for the serial handshaking high event for this
+ port"
+ ::= { evShskHighEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.8.1.6
+
+
+
+--***************************************************************************************
+--No Sensor Event Section 2.12.9
+--***************************************************************************************
+
+evNoSensorTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout (seconds) after which an EventSensor becomes
+ unresponsive that this event is triggered"
+ ::= { evNoSensor 1 }
+ --1.3.6.1.4.1.3052.14.2.12.9.1
+
+evNoSensorActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for no sensor event"
+ ::= { evNoSensor 2 }
+ --1.3.6.1.4.1.3052.14.2.12.9.2
+
+evNoSensorTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for no sensor event"
+ ::= { evNoSensor 3 }
+ --1.3.6.1.4.1.3052.14.2.12.9.3
+
+evNoSensorClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for no sensor event"
+ ::= { evNoSensor 4 }
+ --1.3.6.1.4.1.3052.14.2.12.9.4
+
+
+
+--***************************************************************************************
+--Fuel Sensor Config Section 2.12.11
+--***************************************************************************************
+
+
+fuelSensorGeneralTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes general fuel sensor attributes."
+ ::= { fuelSensor 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1
+
+fsGenEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor general config table."
+ INDEX { fsGenIndex }
+ ::= { fuelSensorGeneralTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1
+
+fsGenIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor general config table."
+ ::= { fsGenEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.1
+
+fsGenName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor name."
+ ::= { fsGenEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.2
+
+fsGenSensorType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of fuel sensor in use; NONE disables the fuel sensor."
+ ::= { fsGenEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.3
+
+fsGenDistanceUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance units in use when setting and indicating tank dimensions."
+ ::= { fsGenEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.4
+
+fsGenRawValueTop OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input reading corresponding to the SENSOR FULL point."
+ ::= { fsGenEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.5
+
+fsGenTopOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance, in the specified distance unit, between the SENSOR FULL
+ point and the TANK FULL point. The value is positive if the
+ SENSOR FULL point is above the TANK FULL point, and negative if it is
+ below."
+ ::= { fsGenEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.6
+
+fsGenRawValueBottom OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Analog input reading corresponding to the minimum fluid height
+ measurable by the fuel sensor."
+ ::= { fsGenEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.7
+
+fsGenBottomOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Distance, in the specified distance unit, between the SENSOR EMPTY
+ point and the TANK EMPTY point. The value is positive if the
+ SENSOR EMPTY point is above the TANK EMPTY point, and negative if it
+ is below."
+ ::= { fsGenEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.8
+
+fsGenInputES OBJECT-TYPE
+ SYNTAX Integer32 (1..200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which eventsensor contains the analog input associated with this fuel
+ sensor. Allowed values are 200 (for internal ES), or 1-16."
+ ::= { fsGenEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.9
+
+fsGenInputPoint OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which analog input point, on the specified eventsensor, that is
+ associated with the fuel sensor."
+ ::= { fsGenEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.10
+
+fsGenFilterAveraging OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor filter averaging factor."
+ ::= { fsGenEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.11
+
+fsGenSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting enable."
+ ::= { fsGenEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.12
+
+fsGenSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting threshold (floating point value)."
+ ::= { fsGenEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.13
+
+fsGenSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting limit."
+ ::= { fsGenEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.14
+
+fsGenSysrepPackage OBJECT-TYPE
+ SYNTAX Integer32 (0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor System Reporting package number."
+ ::= { fsGenEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.15
+
+fsGenSysrepType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor ASM profile type."
+ ::= { fsGenEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.16
+
+fsGenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor enable."
+ ::= { fsGenEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.11.1.1.17
+
+
+fuelSensorTankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigTank
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes tank-specific fuel sensor attributes."
+ ::= { fuelSensor 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2
+
+fsTankEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigTank
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor tank config table."
+ INDEX { fsTankIndex }
+ ::= { fuelSensorTankTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1
+
+fsTankIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor tank config table."
+ ::= { fsTankEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.1
+
+fsTankHeight OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Height of the tank, from the TANK EMPTY point to the TANK FULL point,
+ in the specified distance unit (i.e. TANK HEIGHT). This is a
+ floating point value."
+ ::= { fsTankEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.2
+
+fsTankDimA OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tank dimension measurement A for certain tank profiles. For
+ HORIZ OVAL, this is the length of the straight section. This is a
+ floating point value."
+ ::= { fsTankEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.3
+
+fsTankDimB OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tank dimension measurement B for certain tank profiles. For
+ HORIZ OVAL, this is the radius of the curved section. This is a
+ floating point value."
+ ::= { fsTankEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.4
+
+fsTankVolume OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How many volume units the tank contains, when full. This is a
+ floating point value."
+ ::= { fsTankEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.5
+
+fsTankVolumeUnit OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of the unit representing fluid volume in the tank. This is only
+ used for display purposes; it does not affect the volume calculation."
+ ::= { fsTankEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.6
+
+fsTankShape OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The shape of the fuel tank. A value of LINEAR produces a fluid
+ volume reading that is directly proportional to fluid height. The
+ HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to
+ calculate the volume. The CUSTOM setting uses a strapping table that
+ must be configured as well (see fuelSensorCustomTankTable)."
+ ::= { fsTankEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.11.2.1.7
+
+
+fuelSensorCustomTankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigCustomTankStrapping
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes the custom tank strapping table. Each fuel
+ sensor has a table of height/volume pairs in service only when the tank
+ shape (fsTankShape) in CUSTOM. This allows the unit to calculate
+ volumes for nonstandard tank shapes, to the degree that accurate
+ height/volume measurements can be configured. This SNMP table has two
+ indexes: the first for which fuel sensor and the second for which
+ height/volume pair."
+ ::= { fuelSensor 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3
+
+fsCustomTankEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigCustomTankStrapping
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor custom tank config table."
+ INDEX { fsCustomTankIndexFS, fsCustomTankIndexDatum }
+ ::= { fuelSensorCustomTankTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1
+
+fsCustomTankIndexFS OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor tank config table. This is the
+ first of two indexes for this SNMP table."
+ ::= { fsCustomTankEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1.1
+
+fsCustomTankIndexDatum OBJECT-TYPE
+ SYNTAX Integer32 (1..32)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which hight/volume pair: there are 32 pairs per fuel sensor. This is
+ the second of two indexes for this SNMP table."
+ ::= { fsCustomTankEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1.2
+
+fsCustomTankHeight OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Height of custom tank height/volume pair. This is a floating point
+ value."
+ ::= { fsCustomTankEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1.3
+
+fsCustomTankVolume OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volume of custom tank height/volume pair. This is a floating point
+ value."
+ ::= { fsCustomTankEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.3.1.4
+
+
+fuelSensorVolumeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigVolume
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes volume-event-specific fuel sensor attributes."
+ ::= { fuelSensor 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4
+
+fsVolumeEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigVolume
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor volume event config table."
+ INDEX { fsVolumeIndex }
+ ::= { fuelSensorVolumeTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1
+
+fsVolumeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor volume event config table."
+ ::= { fsVolumeEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.1
+
+fsVolumeEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable fuel sensor volume events."
+ ::= { fsVolumeEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.2
+
+fsVolumeDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor deadband (hysteresis). This is a floating point value."
+ ::= { fsVolumeEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.3
+
+fsVolumeVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold value. This is a
+ floating point value."
+ ::= { fsVolumeEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.4
+
+fsVolumeVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold actions."
+ ::= { fsVolumeEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.5
+
+fsVolumeVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold trap number."
+ ::= { fsVolumeEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.6
+
+fsVolumeVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very high event threshold class (severity)."
+ ::= { fsVolumeEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.7
+
+fsVolumeHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold value. This is a floating
+ point value."
+ ::= { fsVolumeEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.8
+
+fsVolumeHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold actions."
+ ::= { fsVolumeEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.9
+
+fsVolumeHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold trap number."
+ ::= { fsVolumeEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.10
+
+fsVolumeHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume high event threshold class (severity)."
+ ::= { fsVolumeEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.11
+
+fsVolumeNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal actions."
+ ::= { fsVolumeEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.12
+
+fsVolumeNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal trap number."
+ ::= { fsVolumeEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.13
+
+fsVolumeNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume return to normal class (severity)."
+ ::= { fsVolumeEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.14
+
+fsVolumeLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold value. This is a floating
+ point value."
+ ::= { fsVolumeEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.15
+
+fsVolumeLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold actions."
+ ::= { fsVolumeEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.16
+
+fsVolumeLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold trap number."
+ ::= { fsVolumeEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.17
+
+fsVolumeLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume low event threshold class (severity)."
+ ::= { fsVolumeEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.18
+
+fsVolumeVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold value. This is a
+ floating point value."
+ ::= { fsVolumeEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.19
+
+fsVolumeVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold actions."
+ ::= { fsVolumeEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.20
+
+fsVolumeVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (519..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold trap number."
+ ::= { fsVolumeEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.21
+
+fsVolumeVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor volume very low event threshold class (severity)."
+ ::= { fsVolumeEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.11.4.1.22
+
+
+
+fuelSensorDisconnectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FuelSensorConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes disconnect-event-specific fuel sensor attributes."
+ ::= { fuelSensor 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5
+
+fsDiscEntry OBJECT-TYPE
+ SYNTAX FuelSensorConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for fuel sensor disconnect event config table."
+ INDEX { fsDiscIndex }
+ ::= { fuelSensorDisconnectTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1
+
+fsDiscIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which fuel sensor in the fuel sensor disconnect event config table."
+ ::= { fsDiscEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.1
+
+fsDiscEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event enable."
+ ::= { fsDiscEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.2
+
+fsDiscHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High end of input value range when fuel sensor is disconnected. This
+ is in the units of the analog input value."
+ ::= { fsDiscEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.3
+
+fsDiscLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low end of input value range when fuel sensor is disconnected. This
+ is in the units of the analog input value."
+ ::= { fsDiscEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.4
+
+fsDiscActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event actions."
+ ::= { fsDiscEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.5
+
+fsDiscTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (515..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event trap number."
+ ::= { fsDiscEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.6
+
+fsDiscClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect event class (severity)."
+ ::= { fsDiscEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.7
+
+fsDiscNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal actions."
+ ::= { fsDiscEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.8
+
+fsDiscNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (515..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal trap number."
+ ::= { fsDiscEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.9
+
+fsDiscNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Fuel sensor disconnect return to normal class (severity)."
+ ::= { fsDiscEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.11.5.1.10
+
+
+--***************************************************************************************
+--AC Power Monitor Config Section 2.12.12
+--***************************************************************************************
+
+acpmGeneralTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes general AC power monitor attributes."
+ ::= { acPowerMonitor 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1
+
+acpmGenEntry OBJECT-TYPE
+ SYNTAX ACPMConfigGeneral
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor general config table."
+ INDEX { acpmGenIndex }
+ ::= { acpmGeneralTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1
+
+acpmGenIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor general config table."
+ ::= { acpmGenEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.1
+
+acpmGenDevice OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Model of the AC power monitor device. The unit needs this setting to
+ know which registers to poll for the various data items, among other
+ things."
+ ::= { acpmGenEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.2
+
+acpmGenName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name for the AC power monitor device."
+ ::= { acpmGenEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.3
+
+acpmGenAddress OBJECT-TYPE
+ SYNTAX Integer32 (1..247)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Modbus address of the AC power monitor device."
+ ::= { acpmGenEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.4
+
+acpmGenPtRatio OBJECT-TYPE
+ SYNTAX Integer32 (1..10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ratio of secondary turns to primary turns on potential transformers
+ (PT)."
+ ::= { acpmGenEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.5
+
+acpmGenCtRatio OBJECT-TYPE
+ SYNTAX Integer32 (1..10000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Ratio of secondary turns to primary turns on current transformers
+ (CT)."
+ ::= { acpmGenEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.6
+
+acpmGenPowerType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of power being monitored."
+ ::= { acpmGenEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.7
+
+acpmGenSysrepPackage OBJECT-TYPE
+ SYNTAX Integer32 (0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting package number."
+ ::= { acpmGenEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.8
+
+acpmGenSysrepType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ASM profile type."
+ ::= { acpmGenEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.9
+
+acpmGenEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "AC power monitor enable."
+ ::= { acpmGenEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.1.1.10
+
+
+acpmAvgVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigAvgVoltage
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor average voltage attributes."
+ ::= { acPowerMonitor 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2
+
+acpmAvgVoltageEntry OBJECT-TYPE
+ SYNTAX ACPMConfigAvgVoltage
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor average voltage config table."
+ INDEX { acpmAvgVoltageIndex }
+ ::= { acpmAvgVoltageTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1
+
+acpmAvgVoltageIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor average voltage config
+ table."
+ ::= { acpmAvgVoltageEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.1
+
+acpmAvgVoltageEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor average voltage events."
+ ::= { acpmAvgVoltageEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.2
+
+acpmAvgVoltageDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for average voltage event. This is a floating
+ point value."
+ ::= { acpmAvgVoltageEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.3
+
+acpmAvgVoltageVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.4
+
+acpmAvgVoltageVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmAvgVoltageEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.5
+
+acpmAvgVoltageVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmAvgVoltageEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.6
+
+acpmAvgVoltageVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmAvgVoltageEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.7
+
+acpmAvgVoltageHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.8
+
+acpmAvgVoltageHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmAvgVoltageEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.9
+
+acpmAvgVoltageHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmAvgVoltageEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.10
+
+acpmAvgVoltageHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmAvgVoltageEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.11
+
+acpmAvgVoltageNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmAvgVoltageEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.12
+
+acpmAvgVoltageNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmAvgVoltageEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.13
+
+acpmAvgVoltageNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmAvgVoltageEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.14
+
+acpmAvgVoltageLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.15
+
+acpmAvgVoltageLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmAvgVoltageEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.16
+
+acpmAvgVoltageLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmAvgVoltageEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.17
+
+acpmAvgVoltageLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmAvgVoltageEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.18
+
+acpmAvgVoltageVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmAvgVoltageEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.19
+
+acpmAvgVoltageVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmAvgVoltageEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.20
+
+acpmAvgVoltageVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (520..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmAvgVoltageEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.21
+
+acpmAvgVoltageVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmAvgVoltageEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.22
+
+acpmAvgVoltageSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for average voltage telemetry."
+ ::= { acpmAvgVoltageEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.23
+
+acpmAvgVoltageSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for average voltage telemetry. This is
+ a floating point value."
+ ::= { acpmAvgVoltageEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.24
+
+acpmAvgVoltageSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for average voltage telemetry."
+ ::= { acpmAvgVoltageEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.12.12.2.1.25
+
+
+acpmAvgCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigAvgCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor average current attributes."
+ ::= { acPowerMonitor 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3
+
+acpmAvgCurrentEntry OBJECT-TYPE
+ SYNTAX ACPMConfigAvgCurrent
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor average current config table."
+ INDEX { acpmAvgCurrentIndex }
+ ::= { acpmAvgCurrentTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1
+
+acpmAvgCurrentIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor average current
+ config table."
+ ::= { acpmAvgCurrentEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.1
+
+acpmAvgCurrentEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor average current events."
+ ::= { acpmAvgCurrentEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.2
+
+acpmAvgCurrentDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for average current event. This is a floating
+ point value."
+ ::= { acpmAvgCurrentEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.3
+
+acpmAvgCurrentVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.4
+
+acpmAvgCurrentVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmAvgCurrentEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.5
+
+acpmAvgCurrentVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmAvgCurrentEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.6
+
+acpmAvgCurrentVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmAvgCurrentEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.7
+
+acpmAvgCurrentHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.8
+
+acpmAvgCurrentHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmAvgCurrentEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.9
+
+acpmAvgCurrentHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmAvgCurrentEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.10
+
+acpmAvgCurrentHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmAvgCurrentEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.11
+
+acpmAvgCurrentNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmAvgCurrentEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.12
+
+acpmAvgCurrentNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmAvgCurrentEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.13
+
+acpmAvgCurrentNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmAvgCurrentEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.14
+
+acpmAvgCurrentLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.15
+
+acpmAvgCurrentLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmAvgCurrentEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.16
+
+acpmAvgCurrentLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmAvgCurrentEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.17
+
+acpmAvgCurrentLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmAvgCurrentEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.18
+
+acpmAvgCurrentVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmAvgCurrentEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.19
+
+acpmAvgCurrentVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmAvgCurrentEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.20
+
+acpmAvgCurrentVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (521..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmAvgCurrentEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.21
+
+acpmAvgCurrentVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmAvgCurrentEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.22
+
+acpmAvgCurrentSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for average current telemetry."
+ ::= { acpmAvgCurrentEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.23
+
+acpmAvgCurrentSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for average current telemetry. This is a
+ floating point value."
+ ::= { acpmAvgCurrentEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.24
+
+acpmAvgCurrentSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for average current telemetry."
+ ::= { acpmAvgCurrentEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.12.12.3.1.25
+
+
+acpmFreqTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigFreq
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor frequency attributes."
+ ::= { acPowerMonitor 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4
+
+acpmFreqEntry OBJECT-TYPE
+ SYNTAX ACPMConfigFreq
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor frequency config table."
+ INDEX { acpmFreqIndex }
+ ::= { acpmFreqTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1
+
+acpmFreqIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor frequency config
+ table."
+ ::= { acpmFreqEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.1
+
+acpmFreqEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor frequency events."
+ ::= { acpmFreqEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.2
+
+acpmFreqDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for frequency event. This is a floating
+ point value."
+ ::= { acpmFreqEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.3
+
+acpmFreqVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.4
+
+acpmFreqVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmFreqEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.5
+
+acpmFreqVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmFreqEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.6
+
+acpmFreqVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmFreqEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.7
+
+acpmFreqHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.8
+
+acpmFreqHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmFreqEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.9
+
+acpmFreqHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmFreqEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.10
+
+acpmFreqHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmFreqEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.11
+
+acpmFreqNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmFreqEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.12
+
+acpmFreqNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmFreqEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.13
+
+acpmFreqNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmFreqEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.14
+
+acpmFreqLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.15
+
+acpmFreqLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmFreqEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.16
+
+acpmFreqLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmFreqEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.17
+
+acpmFreqLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmFreqEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.18
+
+acpmFreqVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmFreqEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.19
+
+acpmFreqVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmFreqEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.20
+
+acpmFreqVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (522..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmFreqEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.21
+
+acpmFreqVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmFreqEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.22
+
+acpmFreqSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for frequency telemetry."
+ ::= { acpmFreqEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.23
+
+acpmFreqSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for frequency telemetry. This is a
+ floating point value."
+ ::= { acpmFreqEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.24
+
+acpmFreqSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for frequency telemetry."
+ ::= { acpmFreqEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.12.12.4.1.25
+
+
+acpmTotalRealPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigTRP
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor total real power attributes."
+ ::= { acPowerMonitor 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5
+
+acpmTRPEntry OBJECT-TYPE
+ SYNTAX ACPMConfigTRP
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor total real power config table."
+ INDEX { acpmTRPIndex }
+ ::= { acpmTotalRealPowerTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1
+
+acpmTRPIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor total real power
+ config table."
+ ::= { acpmTRPEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.1
+
+acpmTRPEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor total real power events."
+ ::= { acpmTRPEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.2
+
+acpmTRPDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis) for total real power event. This is a floating
+ point value."
+ ::= { acpmTRPEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.3
+
+acpmTRPVHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.4
+
+acpmTRPVHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event actions."
+ ::= { acpmTRPEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.5
+
+acpmTRPVHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event trap number."
+ ::= { acpmTRPEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.6
+
+acpmTRPVHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very high event class."
+ ::= { acpmTRPEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.7
+
+acpmTRPHighValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.8
+
+acpmTRPHighActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event actions."
+ ::= { acpmTRPEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.9
+
+acpmTRPHighTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event trap number."
+ ::= { acpmTRPEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.10
+
+acpmTRPHighClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High event class."
+ ::= { acpmTRPEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.11
+
+acpmTRPNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal actions."
+ ::= { acpmTRPEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.12
+
+acpmTRPNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal trap number."
+ ::= { acpmTRPEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.13
+
+acpmTRPNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Return to normal class."
+ ::= { acpmTRPEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.14
+
+acpmTRPLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.15
+
+acpmTRPLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event actions."
+ ::= { acpmTRPEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.16
+
+acpmTRPLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event trap number."
+ ::= { acpmTRPEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.17
+
+acpmTRPLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low event class."
+ ::= { acpmTRPEntry 18 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.18
+
+acpmTRPVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event threshold. This is a floating point value."
+ ::= { acpmTRPEntry 19 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.19
+
+acpmTRPVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event actions."
+ ::= { acpmTRPEntry 20 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.20
+
+acpmTRPVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (523..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event trap number."
+ ::= { acpmTRPEntry 21 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.21
+
+acpmTRPVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very low event class."
+ ::= { acpmTRPEntry 22 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.22
+
+acpmTRPSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable for total real power telemetry."
+ ::= { acpmTRPEntry 23 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.23
+
+acpmTRPSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold for total real power telemetry. This is a
+ floating point value."
+ ::= { acpmTRPEntry 24 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.24
+
+acpmTRPSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit for total real power telemetry."
+ ::= { acpmTRPEntry 25 }
+ --1.3.6.1.4.1.3052.14.2.12.12.5.1.25
+
+
+acpmDisconnectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor device disconnect event
+ attributes."
+ ::= { acPowerMonitor 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6
+
+acpmDisconnectEntry OBJECT-TYPE
+ SYNTAX ACPMConfigDisconnect
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor device disconnect event config table."
+ INDEX { acpmDisconnectIndex }
+ ::= { acpmDisconnectTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1
+
+acpmDisconnectIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor device disconnect
+ event config table."
+ ::= { acpmDisconnectEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.1
+
+acpmDisconnectEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor device disconnect event."
+ ::= { acpmDisconnectEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.2
+
+acpmDisconnectActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for disconnect event."
+ ::= { acpmDisconnectEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.3
+
+acpmDisconnectTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (524..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for disconnect event."
+ ::= { acpmDisconnectEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.4
+
+acpmDisconnectClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for disconnect event."
+ ::= { acpmDisconnectEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.5
+
+acpmDisconnectNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.6
+
+acpmDisconnectNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32 (524..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.7
+
+acpmDisconnectNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class for disconnect return to normal event."
+ ::= { acpmDisconnectEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.6.1.8
+
+acpmTotalPowerFactorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ACPMConfigTotalPowerFactor
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table organizes AC power monitor device total power factor
+ event attributes."
+ ::= { acPowerMonitor 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7
+
+acpmTPFEntry OBJECT-TYPE
+ SYNTAX ACPMConfigTotalPowerFactor
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for AC power monitor device total power factor event config
+ table."
+ INDEX { acpmTPFIndex }
+ ::= { acpmTotalPowerFactorTable 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1
+
+acpmTPFIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which AC power monitor in the AC power monitor device disconnect
+ event config table."
+ ::= { acpmTPFEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.1
+
+acpmTPFEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable AC power monitor device disconnect event."
+ ::= { acpmTPFEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.2
+
+acpmTPFDeadband OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Deadband (hysteresis)."
+ ::= { acpmTPFEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.3
+
+acpmTPFNormalActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal actions."
+ ::= { acpmTPFEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.4
+
+acpmTPFNormalTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal trap number."
+ ::= { acpmTPFEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.5
+
+acpmTPFNormalClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Normal class."
+ ::= { acpmTPFEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.6
+
+acpmTPFLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold."
+ ::= { acpmTPFEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.7
+
+acpmTPFLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low actions."
+ ::= { acpmTPFEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.8
+
+acpmTPFLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low trap number."
+ ::= { acpmTPFEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.9
+
+acpmTPFLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low class."
+ ::= { acpmTPFEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.10
+
+acpmTPFVLowValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low threshold."
+ ::= { acpmTPFEntry 11 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.11
+
+acpmTPFVLowActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low actions."
+ ::= { acpmTPFEntry 12 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.12
+
+acpmTPFVLowTrapNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low trap number."
+ ::= { acpmTPFEntry 13 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.13
+
+acpmTPFVLowClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Very Low class."
+ ::= { acpmTPFEntry 14 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.14
+
+acpmTPFSysrepEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting enable."
+ ::= { acpmTPFEntry 15 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.15
+
+acpmTPFSysrepThreshold OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting threshold."
+ ::= { acpmTPFEntry 16 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.16
+
+acpmTPFSysrepLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "System reporting limit."
+ ::= { acpmTPFEntry 17 }
+ --1.3.6.1.4.1.3052.14.2.12.12.7.1.17
+
+
+
+--***************************************************************************************
+--Reset Event Section 2.12.16
+--***************************************************************************************
+
+
+evResetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable reset event. This event is triggered when the unit
+ finishes booting."
+ ::= { evReset 1 }
+ --1.3.6.1.4.1.3052.14.2.12.16.1
+
+evResetDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..3600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of seconds to wait after unit finishes booting before triggering
+ the reset event."
+ ::= { evReset 2 }
+ --1.3.6.1.4.1.3052.14.2.12.16.2
+
+evResetActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Actions for reset event."
+ ::= { evReset 3 }
+ --1.3.6.1.4.1.3052.14.2.12.16.3
+
+evResetMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message for reset event."
+ ::= { evReset 4 }
+ --1.3.6.1.4.1.3052.14.2.12.16.4
+
+evResetTrapnum OBJECT-TYPE
+ SYNTAX Integer32 (543..1199)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Trap number for reset event."
+ ::= { evReset 5 }
+ --1.3.6.1.4.1.3052.14.2.12.16.5
+
+evResetClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Class (severity) for reset event."
+ ::= { evReset 6 }
+ --1.3.6.1.4.1.3052.14.2.12.16.6
+
+
+--***************************************************************************************
+--Action Section 2.14
+--***************************************************************************************
+
+
+
+actionCallNumberTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionCallNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of phone numbers to dial for modem actions"
+ ::= { action 1 }
+ --1.3.6.1.4.1.3052.14.2.14.1
+
+actionCallNumberEntry OBJECT-TYPE
+ SYNTAX ActionCallNumberConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of phone numbers to dial for modem actions"
+ INDEX { actionCallNumberIndex }
+ ::= { actionCallNumberTable 1 }
+ --1.3.6.1.4.1.3052.14.2.14.1.1
+
+actionCallNumberIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of phone numbers to dial for modem actions"
+ ::= { actionCallNumberEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.14.1.1.1
+
+actionCallNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number to dial for this action slot"
+ ::= { actionCallNumberEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.14.1.1.2
+
+actionPagerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionPagerConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of pager configurations"
+ ::= { action 2 }
+ --1.3.6.1.4.1.3052.14.2.14.2
+
+actionPagerEntry OBJECT-TYPE
+ SYNTAX ActionPagerConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of pager configurations"
+ INDEX { actionPagerIndex }
+ ::= { actionPagerTable 1 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1
+
+actionPagerIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "index for table of pager configurations"
+ ::= { actionPagerEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.1
+
+actionPagerType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "type of this pager configuration"
+ ::= { actionPagerEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.2
+
+actionPagerNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "phone number to dial for this pager configuration"
+ ::= { actionPagerEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.3
+
+actionPagerID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID to use for this pager configuration"
+ ::= { actionPagerEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.4
+
+actionPagerMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "message to use for this pager configuration"
+ ::= { actionPagerEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.5
+
+actionPagerPostCalloutDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait after dialing before sending ID"
+ ::= { actionPagerEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.6
+
+actionPagerPostIDDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Seconds to wait after sending ID to send message"
+ ::= { actionPagerEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.14.2.1.7
+
+actionSchedEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable action schedule"
+ ::= { actionSched 1 }
+ --1.3.6.1.4.1.3052.14.2.14.3.1
+
+actionSchedBegin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "action schedule begin time (HH:MM)"
+ ::= { actionSched 2 }
+ --1.3.6.1.4.1.3052.14.2.14.3.2
+
+actionSchedEnd OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "action schedule end time (HH:MM)"
+ ::= { actionSched 3 }
+ --1.3.6.1.4.1.3052.14.2.14.3.3
+
+actionSchedWeekdaysOnly OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF whether the action schedule applies to weekdays only
+ (ON) or all days (OFF)"
+ ::= { actionSched 4 }
+ --1.3.6.1.4.1.3052.14.2.14.3.4
+
+actionAsentriaRequireAck OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Asentria action requires an ack from the receiver"
+ ::= { actionAsentria 1 }
+ --1.3.6.1.4.1.3052.14.2.14.4.1
+
+actionAsentriaVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "version 1.0 or 1.1"
+ ::= { actionAsentria 2 }
+ --1.3.6.1.4.1.3052.14.2.14.4.2
+
+actionAsentriaTCPPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port used for TCP-based Asentria alarms"
+ ::= { actionAsentria 3 }
+ --1.3.6.1.4.1.3052.14.2.14.4.3
+
+actionHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of network hosts to use for network-based actions"
+ ::= { action 6 }
+ --1.3.6.1.4.1.3052.14.2.14.6
+
+actionHostEntry OBJECT-TYPE
+ SYNTAX ActionHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of network hosts to use for network-based
+ actions"
+ INDEX { actionHostIndex }
+ ::= { actionHostTable 1 }
+ --1.3.6.1.4.1.3052.14.2.14.6.1
+
+actionHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of network hosts to use for network-based
+ actions"
+ ::= { actionHostEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.14.6.1.1
+
+actionHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Hostname/IP address used as destination for network-based
+ action (e.g., trap)"
+ ::= { actionHostEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.14.6.1.2
+
+actionEmailTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ActionEmailConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of email addresses to use for email actions"
+ ::= { action 7 }
+ --1.3.6.1.4.1.3052.14.2.14.7
+
+actionEmailEntry OBJECT-TYPE
+ SYNTAX ActionEmailConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of email addresses to use for email actions"
+ INDEX { actionEmailIndex }
+ ::= { actionEmailTable 1 }
+ --1.3.6.1.4.1.3052.14.2.14.7.1
+
+actionEmailIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of email addresses to use for email actions"
+ ::= { actionEmailEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.14.7.1.1
+
+actionEmail OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "email address"
+ ::= { actionEmailEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.14.7.1.2
+
+actionParseError OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When a user attempts to configure an invalid action setting/
+ object, this object says why it was invalid."
+ ::= { action 8 }
+ --1.3.6.1.4.1.3052.14.2.14.8
+
+--***************************************************************************************
+--System Section 2.16
+--***************************************************************************************
+
+
+sysTimeAutoDST OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF automatically adjust for Daylight Savings Time"
+ ::= { sysTime 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1.1
+
+sysTimeGMTOffset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Absolute value of offset (hours) from GMT of the timezone"
+ ::= { sysTime 2 }
+ --1.3.6.1.4.1.3052.14.2.16.1.2
+
+sysTimeGMTDirection OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Direction (AHEAD/BEHIND) of timezone relative to GMT"
+ ::= { sysTime 3 }
+ --1.3.6.1.4.1.3052.14.2.16.1.3
+
+
+sysTimeNetEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Network time mode"
+ ::= { sysTimeNet 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.1
+
+sysTimeNetHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NetworkTimeHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of hosts to use for network time services"
+ ::= { sysTimeNet 2 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.2
+
+sysTimeNetHostEntry OBJECT-TYPE
+ SYNTAX NetworkTimeHostConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of hosts to use for network time services"
+ INDEX { sysTimeNetHostIndex }
+ ::= { sysTimeNetHostTable 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.2.1
+
+sysTimeNetHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..6)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of hosts to use for network time services"
+ ::= { sysTimeNetHostEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.2.1.1
+
+sysTimeNetHost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "host to use for network time services"
+ ::= { sysTimeNetHostEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.16.1.4.2.1.2
+
+sysPTTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timeout (minutes) of inactivity after which a pass-through
+ session is terminated (0 means it never terminates)"
+ ::= { sysPT 1 }
+ --1.3.6.1.4.1.3052.14.2.16.2.1
+
+sysPTEndPause OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "number of 16ths of a second between escape characters
+ received on pass-through origin IO handle that are reuired
+ for the escape characters to register as pass-through escape
+ characters in the pass-through escape sequence. Set to 0 to
+ make the escape character register as part of the pass-
+ through escape sequence without requiring a pause."
+ ::= { sysPT 2 }
+ --1.3.6.1.4.1.3052.14.2.16.2.2
+
+sysPTJoinable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable joinable pass-through sessions."
+ ::= { sysPT 3 }
+ --1.3.6.1.4.1.3052.14.2.16.2.3
+
+sysMTU OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum transfer unit for ethernet interfaces"
+ ::= { sys 3 }
+ --1.3.6.1.4.1.3052.14.2.16.3
+
+sysAnswerString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String displayed upon login"
+ ::= { sys 4 }
+ --1.3.6.1.4.1.3052.14.2.16.4
+
+sysEventFileID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID string for events file"
+ ::= { sys 6 }
+ --1.3.6.1.4.1.3052.14.2.16.6
+
+sysEscapeCharacter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Decimal ASCII code of the system escape character"
+ ::= { sys 7 }
+ --1.3.6.1.4.1.3052.14.2.16.7
+
+sysTimeStampTimeFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Format of time stamp: HH:MM,HH:MM:SS,BLANK"
+ ::= { sysTimeStamp 1 }
+ --1.3.6.1.4.1.3052.14.2.16.8.1
+
+sysTimeStampDateFormat OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Format of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK"
+ ::= { sysTimeStamp 2 }
+ --1.3.6.1.4.1.3052.14.2.16.8.2
+
+sysTimeStampSpaceAfter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF Inlude a space after timestamp"
+ ::= { sysTimeStamp 3 }
+ --1.3.6.1.4.1.3052.14.2.16.8.3
+
+sysLogMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Syslog mode: disabled, emit UDP (REMOTE), save in a
+ rotating file set (FILE), or emit on a listening socket
+ (SERVER)"
+ ::= { sysLog 1 }
+ --1.3.6.1.4.1.3052.14.2.16.9.1
+
+sysLoghost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Syslog host: destination machine when syslog mode is REMOTE"
+ ::= { sysLog 2 }
+ --1.3.6.1.4.1.3052.14.2.16.9.2
+
+sysLogFilter OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String describing what functions place data in the syslog"
+ ::= { sysLog 3 }
+ --1.3.6.1.4.1.3052.14.2.16.9.3
+
+sysLogFileSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Size (in KB) of syslog files (when syslog mode is SERVER or
+ FILE)"
+ ::= { sysLog 4 }
+ --1.3.6.1.4.1.3052.14.2.16.9.4
+
+sysLogFileCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Number of files in syslog file set (when syslog mode is
+ SERVER or FILE)"
+ ::= { sysLog 5 }
+ --1.3.6.1.4.1.3052.14.2.16.9.5
+
+sysLogListenPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port on which the unit listens for a connection on
+ which syslog data is dumped (when syslog mode is SERVER)"
+ ::= { sysLog 6 }
+ --1.3.6.1.4.1.3052.14.2.16.9.6
+
+sysCRDBCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacity of Call Record Database (in KB)"
+ ::= { sysCRDB 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.1
+
+sysCRDBPercentFull OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of the CRDB used"
+ ::= { sysCRDB 2 }
+ --1.3.6.1.4.1.3052.14.2.16.10.2
+
+
+sysCRDBFileIDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CRDBFileIDConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CRDB file IDs"
+ ::= { sysCRDB 3 }
+ --1.3.6.1.4.1.3052.14.2.16.10.3
+
+sysCRDBFileIDEntry OBJECT-TYPE
+ SYNTAX CRDBFileIDConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CRDB file IDs"
+ INDEX { sysCRDBFileIDIndex }
+ ::= { sysCRDBFileIDTable 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.3.1
+
+sysCRDBFileIDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CRDB file IDs"
+ ::= { sysCRDBFileIDEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.3.1.1
+
+sysCRDBFileID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID of CRDB file for this port-associated file x"
+ ::= { sysCRDBFileIDEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.16.10.3.1.2
+
+sysCRDBFileEnforceMinTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CRDBFileEnforceMinConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of CRDB file minimum size enforcement settings"
+ ::= { sysCRDB 4 }
+ --1.3.6.1.4.1.3052.14.2.16.10.4
+
+sysCRDBFileEnforceMinEntry OBJECT-TYPE
+ SYNTAX CRDBFileEnforceMinConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of CRDB file minimum size enforcement
+ settings"
+ INDEX { sysCRDBFileEnforceMinIndex }
+ ::= { sysCRDBFileEnforceMinTable 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.4.1
+
+sysCRDBFileEnforceMinIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..24)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of CRDB file minimum size enforcement
+ settings"
+ ::= { sysCRDBFileEnforceMinEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.16.10.4.1.1
+
+sysCRDBFileEnforceMin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: enforce minimum size for this CRDB file x"
+ ::= { sysCRDBFileEnforceMinEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.16.10.4.1.2
+
+sysCharMask OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Character mask used for ignoring certain characters on
+ serial ports when assembling data records (when port mode is
+ ASCII)"
+ ::= { sys 11 }
+ --1.3.6.1.4.1.3052.14.2.16.11
+
+sysPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Prompt to use in a commnand session"
+ ::= { sys 12 }
+ --1.3.6.1.4.1.3052.14.2.16.12
+
+sysBootStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "String describing the boot status of the unit (Booted OK/
+ still booting"
+ ::= { sys 13 }
+ --1.3.6.1.4.1.3052.14.2.16.13
+
+sysLocLatitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Latitude portion of geographic coordinates as string"
+ ::= { sysLoc 1 }
+ --1.3.6.1.4.1.3052.14.2.16.14.1
+
+sysLocLongitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Longitude portion of geographic coordinates as string"
+ ::= { sysLoc 2 }
+ --1.3.6.1.4.1.3052.14.2.16.14.2
+
+sysLocXOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "X-offset portion of geographic coordinates as string"
+ ::= { sysLoc 3 }
+ --1.3.6.1.4.1.3052.14.2.16.14.3
+
+sysLocYOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Y offset portion of geographic coordinates as string"
+ ::= { sysLoc 4 }
+ --1.3.6.1.4.1.3052.14.2.16.14.4
+
+sysLocAngle OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Angle portion of geographic coordinates as string"
+ ::= { sysLoc 5 }
+ --1.3.6.1.4.1.3052.14.2.16.14.5
+
+sysLocAltitude OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Altitude portion of geographic coordinates as string"
+ ::= { sysLoc 6 }
+ --1.3.6.1.4.1.3052.14.2.16.14.6
+
+sysAMManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device manufacturer"
+ ::= { sysAssetMgmt 1 }
+ --1.3.6.1.4.1.3052.14.2.16.15.1
+
+sysAMProduct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device product description (i.e., model or model number)"
+ ::= { sysAssetMgmt 2 }
+ --1.3.6.1.4.1.3052.14.2.16.15.2
+
+sysAMSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manufacturer serial number for device"
+ ::= { sysAssetMgmt 3 }
+ --1.3.6.1.4.1.3052.14.2.16.15.3
+
+sysAMHardwareOptions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hardware options currently installed on device"
+ ::= { sysAssetMgmt 4 }
+ --1.3.6.1.4.1.3052.14.2.16.15.4
+
+sysAMSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently-running software version on device"
+ ::= { sysAssetMgmt 5 }
+ --1.3.6.1.4.1.3052.14.2.16.15.5
+
+sysAMSiteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Site Name of device (user definable, also known as the
+ siteName object under the productIds branch."
+ ::= { sysAssetMgmt 6 }
+ --1.3.6.1.4.1.3052.14.2.16.15.6
+
+
+--***************************************************************************************
+--Sys File Transfer Section 2.16.17
+--***************************************************************************************
+
+sysFileTransferStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Start/cancel file transfer, or check transfer status. To start, set this object
+ to 'start'. To cancel, set this object to 'cancel'. To check status, get the
+ object"
+ ::= { sysFileTransfer 1 }
+ --1.3.6.1.4.1.3052.14.2.16.17.1
+
+sysFileTransferURL OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "URL (describing protocol, host, directory, and file) on which file transfer
+ function operates."
+ ::= { sysFileTransfer 2 }
+ --1.3.6.1.4.1.3052.14.2.16.17.2
+
+sysFileTransferUsername OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Username for user account at the resource specified by sysFileTransferURL."
+ ::= { sysFileTransfer 3 }
+ --1.3.6.1.4.1.3052.14.2.16.17.3
+
+sysFileTransferPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Password for user account at the resource specified by sysFileTransferURL."
+ ::= { sysFileTransfer 4 }
+ --1.3.6.1.4.1.3052.14.2.16.17.4
+
+--***************************************************************************************
+--Sys Update Section 2.16.18
+--***************************************************************************************
+
+sysUpdateStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Check time/result of last update attempt."
+ ::= { sysUpdate 1 }
+ --1.3.6.1.4.1.3052.14.2.16.18.1
+
+
+--***************************************************************************************
+--Audit Log Section 2.17
+--***************************************************************************************
+
+auditLogEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable audit log"
+ ::= { auditLog 1 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreResets OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when the unit resets"
+ ::= { auditLog 2 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreCommands OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores commands entered in a command
+ session"
+ ::= { auditLog 3 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreOutputs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores output (relay output and power output)
+ activity"
+ ::= { auditLog 4 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreAlarmActions OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores action delivery activity"
+ ::= { auditLog 5 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStorePwdFailures OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when user was denied login"
+ ::= { auditLog 6 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreLogins OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when a user was allowed login"
+ ::= { auditLog 7 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreSHSK OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores serial handshaking status
+ (regardless of serial handshaking event)"
+ ::= { auditLog 8 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStorePassthrough OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores pass-through activity"
+ ::= { auditLog 9 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStoreInactivity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores when sessions expire due to
+ inactivity"
+ ::= { auditLog 10 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogStorePolling OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF audit log stores CRDB polling activity"
+ ::= { auditLog 11 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+auditLogMaxSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum size (in KB) of audit log"
+ ::= { auditLog 12 }
+ --1.3.6.1.4.1.3052.14.2.17.1
+
+--***************************************************************************************
+--Scripting Section 2.17
+--***************************************************************************************
+
+scrGlobalEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable scripting"
+ ::= { scripting 1 }
+ --1.3.6.1.4.1.3052.14.2.18.1
+
+scrDTRCtrlPortEnableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingDTRCtrlPortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of DTR control port enables"
+ ::= { scripting 2 }
+ --1.3.6.1.4.1.3052.14.2.18.2
+
+scrDTRCtrlPortEnableEntry OBJECT-TYPE
+ SYNTAX ScriptingDTRCtrlPortEnableConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of DTR control port enables"
+ INDEX { scrDTRCtrlPortEnableIndex }
+ ::= { scrDTRCtrlPortEnableTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.2.1
+
+scrDTRCtrlPortEnableIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of DTR control port enables"
+ ::= { scrDTRCtrlPortEnableEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.2.1.1
+
+scrDTRCtrlPortEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable DTR control of scripting for this port"
+ ::= { scrDTRCtrlPortEnableEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.2.1.2
+
+
+scrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of scripts"
+ ::= { scripting 3 }
+ --1.3.6.1.4.1.3052.14.2.18.3
+
+scrEntry OBJECT-TYPE
+ SYNTAX ScriptingConfig
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of scripts"
+ INDEX { scrIndex }
+ ::= { scrTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1
+
+scrIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of scripts"
+ ::= { scrEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.1
+
+scrEnable OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF enable this script"
+ ::= { scrEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.2
+
+scrName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Name of this script"
+ ::= { scrEntry 3 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.3
+
+scrFilename OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Filename for this script"
+ ::= { scrEntry 4 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.4
+
+scrRunAlways OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script always runs"
+ ::= { scrEntry 5 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.5
+
+scrRunAtStartup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script runs at startup"
+ ::= { scrEntry 6 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.6
+
+scrRunScheduled OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ON/OFF: this script runs at a certain time of day"
+ ::= { scrEntry 7 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.7
+
+scrScheduleTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time of day (HH:MM) this script is scheduled to run"
+ ::= { scrEntry 8 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.8
+
+scrArguments OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Arguments for this script"
+ ::= { scrEntry 9 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.9
+
+scrRepeatInterval OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "How often this script runs (minutes)"
+ ::= { scrEntry 10 }
+ --1.3.6.1.4.1.3052.14.2.18.3.1.10
+
+scrVolatileStringTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of volatile string settings for use in
+ scripts."
+ ::= { scripting 4 }
+ --1.3.6.1.4.1.3052.14.2.18.4
+
+scrVolatileStringEntry OBJECT-TYPE
+ SYNTAX ScriptingVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of volatile script string
+ settings"
+ INDEX { scrVolatileStringIndex }
+ ::= { scrVolatileStringTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.4.1
+
+scrVolatileStringIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of volatile script string
+ settings"
+ ::= { scrVolatileStringEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.4.1.1
+
+scrVolatileString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volatile string for use in scripts. Use this
+ object to cache frequently-changing string values
+ or string values that do not need to persist
+ through reset. This object corresponds to the
+ scripting.vstring[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object."
+ ::= { scrVolatileStringEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.4.1.2
+
+scrVolatileIntTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of volatile integer settings for use in
+ scripts."
+ ::= { scripting 5 }
+ --1.3.6.1.4.1.3052.14.2.18.5
+
+scrVolatileIntEntry OBJECT-TYPE
+ SYNTAX ScriptingVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of volatile script integer
+ settings"
+ INDEX { scrVolatileIntIndex }
+ ::= { scrVolatileIntTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.5.1
+
+scrVolatileIntIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of volatile script integer
+ settings"
+ ::= { scrVolatileIntEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.5.1.1
+
+scrVolatileInt OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Volatile integer for use in scripts. Use this
+ object to cache frequently-changing integer values
+ or integer values that do not need to persist
+ through reset. This object corresponds to the
+ scripting.vint[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object."
+ ::= { scrVolatileIntEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.5.1.2
+
+scrNonVolatileStringTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingNonVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of non-volatile string settings for use in
+ scripts."
+ ::= { scripting 6 }
+ --1.3.6.1.4.1.3052.14.2.18.6
+
+scrNonVolatileStringEntry OBJECT-TYPE
+ SYNTAX ScriptingNonVolatileString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of non-volatile script string
+ settings"
+ INDEX { scrNonVolatileStringIndex }
+ ::= { scrNonVolatileStringTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.6.1
+
+scrNonVolatileStringIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of non-volatile script string
+ settings"
+ ::= { scrNonVolatileStringEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.6.1.1
+
+scrNonVolatileString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Non-volatile string for use in scripts. Use this
+ object to store values that need to persist
+ through reset. This object corresponds to the
+ scripting.nvstring[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object. Note: to store frequently-
+ changing integers, use the scrVolatileString object,
+ otherwise your scripts may cause unnecessary wear of
+ the non-volatile storage medium on the unit."
+ ::= { scrNonVolatileStringEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.6.1.2
+
+scrNonVolatileIntTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ScriptingNonVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of non-volatile integer settings for use in
+ scripts."
+ ::= { scripting 7 }
+ --1.3.6.1.4.1.3052.14.2.18.7
+
+scrNonVolatileIntEntry OBJECT-TYPE
+ SYNTAX ScriptingNonVolatileInt
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for table of non-volatile script integer
+ settings"
+ INDEX { scrNonVolatileIntIndex }
+ ::= { scrNonVolatileIntTable 1 }
+ --1.3.6.1.4.1.3052.14.2.18.7.1
+
+scrNonVolatileIntIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..50)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for table of non-volatile script integer
+ settings"
+ ::= { scrNonVolatileIntEntry 1 }
+ --1.3.6.1.4.1.3052.14.2.18.7.1.1
+
+scrNonVolatileInt OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Non-volatile integer for use in scripts. Use this
+ object to store integer values that need to persist
+ through reset. This object corresponds to the
+ scripting.nvint[] setting key branch; use those
+ keys in scripts and you can view or change their
+ values with this object. Note: to store frequently-
+ changing integers, use the scrVolatileInt object,
+ otherwise your scripts may cause unnecessary wear of
+ the non-volatile storage medium on the unit."
+ ::= { scrNonVolatileIntEntry 2 }
+ --1.3.6.1.4.1.3052.14.2.18.7.1.2
+
+--***************************************************************************************
+--Product IDs Section 3
+--***************************************************************************************
+
+siteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Site Name string; Max 40 characters."
+ ::= { productIds 1 }
+ --1.3.6.1.4.1.3052.14.3.1
+
+thisProduct OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is a factory configured string for the
+ product name."
+ ::= { productIds 2 }
+ --1.3.6.1.4.1.3052.14.3.2
+
+stockTrapString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The message defined for the event that triggers a trap."
+ ::= { productIds 3 }
+ --1.3.6.1.4.1.3052.14.3.3
+
+trapEventTypeNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the type of
+ event that happened. Definitions:
+ 4 Scheduled
+ 7 Serial Handshaking Low
+ 8 Serial Handshaking High
+ 10 Contact Closure Active
+ 11 Contact Closure Inactive
+ 12 Temperature High
+ 13 Temperature Very High
+ 14 Temperature Low
+ 15 Temperature Very Low
+ 16 Temperature Return to Normal
+ 17 Humidity High
+ 18 Humidity Very High
+ 19 Humidity Low
+ 20 Humidity Very Low
+ 21 Humidity Return to Normal
+ 26 Analog High
+ 27 Analog Very High
+ 28 Analog Low
+ 29 Analog Very Low
+ 30 Analog Normal
+ 40 EventSensor Unresponsive
+ 41 Custom
+ 42 CPE Down
+ 44 CPE Normal
+ 47 Power Distribution
+ 49 Fuel Sensor Disconnect
+ 50 Fuel Sensor Disconnect Return to Normal
+ 52 AISG Device Alarm
+ 53 AISG Device Alarm Return to Normal
+ 54 AISG Device Unresponsive
+ 55 AISG Device Unresponsive Return to Normal
+ 56 Fuel Sensor
+ 57 AC Power Monitor Average Voltage Very Low
+ 58 AC Power Monitor Average Voltage Low
+ 59 AC Power Monitor Average Voltage Return to Normal
+ 60 AC Power Monitor Average Voltage High
+ 61 AC Power Monitor Average Voltage Very High
+ 62 AC Power Monitor Average Current Very Low
+ 63 AC Power Monitor Average Current Low
+ 64 AC Power Monitor Average Current Return to Normal
+ 65 AC Power Monitor Average Current High
+ 66 AC Power Monitor Average Current Very High
+ 67 AC Power Monitor Frequency Very Low
+ 68 AC Power Monitor Frequency Low
+ 69 AC Power Monitor Frequency Return to Normal
+ 70 AC Power Monitor Frequency High
+ 71 AC Power Monitor Frequency Very High
+ 72 AC Power Monitor Total Real Power Very Low
+ 73 AC Power Monitor Total Real Power Low
+ 74 AC Power Monitor Total Real Power Return to Normal
+ 75 AC Power Monitor Total Real Power High
+ 76 AC Power Monitor Total Real Power Very High
+ 77 AC Power Monitor Disconnect
+ 78 AC Power Monitor Disconnect Return to Normal
+ 79 Load Shedding Started
+ 80 Load Shedding Ended
+ 81 Fuel Sensor Volume Sudden Change
+ 82 Fuel Sensor Volume Slow Change
+ 83 CPE Down Reminder
+ 84 AC Power Monitor Total Power Factor Very Low
+ 85 AC Power Monitor Total Power Factor Low
+ 86 AC Power Monitor Total Power Factor Return to Normal
+ 100 Contact Closure Active Reminder
+ 101 Temperature High Reminder
+ 102 Temperature High Very Reminder
+ 103 Temperature Low Reminder
+ 104 Temperature Very Low Reminder
+ 105 Humidity High Reminder
+ 106 Humidity Very High Reminder
+ 107 Humidity Low Reminder
+ 108 Humidity Very Low Reminder
+ 109 Analog High Reminder
+ 110 Analog Very High Reminder
+ 111 Analog Low Reminder
+ 112 Analog Very Low Reminder
+ 130 Relay Output Active
+ 131 Relay Output Inactive
+ 132 Power Output On
+ 133 Power Output Off
+ 164 Reset
+ 166 Fuel Sensor Levels Auto Adjust
+ "
+ ::= { productIds 4 }
+ --1.3.6.1.4.1.3052.14.3.4
+
+trapEventTypeName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the string
+ corresponding to the event type."
+ ::= { productIds 5 }
+ --1.3.6.1.4.1.3052.14.3.5
+
+trapIncludedValue OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the generic
+ included value."
+ ::= { productIds 6 }
+ --1.3.6.1.4.1.3052.14.3.6
+
+trapIncludedString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the generic
+ included string."
+ ::= { productIds 7 }
+ --1.3.6.1.4.1.3052.14.3.7
+
+trapTypeString OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The cause of the trap, added for DL880 compatibility."
+ ::= { productIds 8 }
+ --1.3.6.1.4.1.3052.14.3.8
+
+trapEventClassNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the configurable
+ class number associated with the triggering event."
+ ::= { productIds 9 }
+ --1.3.6.1.4.1.3052.14.3.9
+
+trapEventClassName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined trap variable for the configurable
+ class name associated with the class number."
+ ::= { productIds 10 }
+ --1.3.6.1.4.1.3052.14.3.10
+
+
+--***************************************************************************************
+--Product IDs Section 3
+--***************************************************************************************
+
+keyInterface OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object represents a setting key interface. When
+ setting this object, the value to set is the 'sk' command
+ you would enter on the command line (without the 'sk'). To
+ get the result of the operation, read this object after you
+ write it.
+
+ For example, to configure EventSensor 1 contact closure 34
+ event actions to be an SNMP InformRequest to host foo, set
+ this object to:
+ 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP
+ response is the result of the operation: if setting that key
+ to that value was a success then the SNMP response will be a
+ success and the response value will be what you had set. If
+ you subsequently read this object then you will see a
+ message 'OK: ...'.
+
+ If setting that key to that value failed then the SNMP
+ response will be a failure (a badValue response). If you
+ subsequently read this object then the value returned is the
+ reason that setting that key to that value failed.
+
+ For another example, to read user 3's pass-through access
+ for port 7, set this object to:
+ 'sec.user[3].port[7].ptaccess'. The SNMP response is the
+ result of the operation: if reading that key is a success
+ then the SNMP response will be a success and the response
+ value will be what you had SET (i.e., the opertion of
+ reading a key, which is just the key itself with no '='
+ operator, and this is not the key value you want to read).
+ If you subsequently read this object then the value
+ returned is the value of the key you want to read.
+
+ If reading that key failed (e.g., if the key is invalid)
+ then the SNMP response to your SNMP set operation (the
+ value you set being the invalid key to read) will be a
+ failure (a badValue response). If you subsequently read
+ this object then the value returned is the reason that
+ reading that key failed (i.e., 'invalid key')."
+ ::= { s571 4 }
+ --1.3.6.1.4.1.3052.14.4
+
+
+--***************************************************************************************
+--TABLE DEFINITIONS
+--***************************************************************************************
+
+ESPointConfigTemp ::=
+ SEQUENCE {
+ espcTempIndexES
+ Integer32,
+ espcTempIndexPoint
+ Integer32,
+ espcTempEnable
+ DisplayString,
+ espcTempScale
+ DisplayString,
+ espcTempDeadband
+ DisplayString,
+ espcTempVHighTemp
+ DisplayString,
+ espcTempVHighActions
+ DisplayString,
+ espcTempVHighTrapnum
+ Integer32,
+ espcTempVHighClass
+ DisplayString,
+ espcTempHighTemp
+ DisplayString,
+ espcTempHighActions
+ DisplayString,
+ espcTempHighTrapnum
+ Integer32,
+ espcTempHighClass
+ DisplayString,
+ espcTempNormalActions
+ DisplayString,
+ espcTempNormalTrapnum
+ Integer32,
+ espcTempNormalClass
+ DisplayString,
+ espcTempLowTemp
+ DisplayString,
+ espcTempLowActions
+ DisplayString,
+ espcTempLowTrapnum
+ Integer32,
+ espcTempLowClass
+ DisplayString,
+ espcTempVLowTemp
+ DisplayString,
+ espcTempVLowActions
+ DisplayString,
+ espcTempVLowTrapnum
+ Integer32,
+ espcTempVLowClass
+ DisplayString
+}
+
+
+ESPointConfigCC ::=
+ SEQUENCE {
+ espcCCIndexES
+ Integer32,
+ espcCCIndexPoint
+ Integer32,
+ espcCCEnable
+ DisplayString,
+ espcCCName
+ DisplayString,
+ espcCCEventState
+ DisplayString,
+ espcCCThreshold
+ Integer32,
+ espcCCEventActions
+ DisplayString,
+ espcCCEventTrapnum
+ Integer32,
+ espcCCEventClass
+ DisplayString,
+ espcCCNormalActions
+ DisplayString,
+ espcCCNormalTrapnum
+ Integer32,
+ espcCCNormalClass
+ DisplayString,
+ espcCCAlarmAlias
+ DisplayString,
+ espcCCNormalAlias
+ DisplayString,
+ espcCCNormalThreshold
+ Integer32,
+ espcCCOverrideGlobalReminder
+ DisplayString,
+ espcCCReminderInterval
+ Integer32
+}
+
+ESPointConfigHumid ::=
+ SEQUENCE {
+ espcHumidIndexES
+ Integer32,
+ espcHumidIndexPoint
+ Integer32,
+ espcHumidEnable
+ DisplayString,
+ espcHumidDeadband
+ Integer32,
+ espcHumidVHighHumid
+ Integer32,
+ espcHumidVHighActions
+ DisplayString,
+ espcHumidVHighTrapnum
+ Integer32,
+ espcHumidVHighClass
+ DisplayString,
+ espcHumidHighHumid
+ Integer32,
+ espcHumidHighActions
+ DisplayString,
+ espcHumidHighTrapnum
+ Integer32,
+ espcHumidHighClass
+ DisplayString,
+ espcHumidNormalActions
+ DisplayString,
+ espcHumidNormalTrapnum
+ Integer32,
+ espcHumidNormalClass
+ DisplayString,
+ espcHumidLowHumid
+ Integer32,
+ espcHumidLowActions
+ DisplayString,
+ espcHumidLowTrapnum
+ Integer32,
+ espcHumidLowClass
+ DisplayString,
+ espcHumidVLowHumid
+ Integer32,
+ espcHumidVLowActions
+ DisplayString,
+ espcHumidVLowTrapnum
+ Integer32,
+ espcHumidVLowClass
+ DisplayString
+}
+
+ESPointConfigAnalogInput ::=
+ SEQUENCE {
+ espcAIIndexES
+ Integer32,
+ espcAIIndexPoint
+ Integer32,
+ espcAIEnable
+ DisplayString,
+ espcAIDeadband
+ DisplayString,
+ espcAIVhighValue
+ DisplayString,
+ espcAIVhighActions
+ DisplayString,
+ espcAIVhighTrapnum
+ Integer32,
+ espcAIVhighClass
+ DisplayString,
+ espcAIHighValue
+ DisplayString,
+ espcAIHighActions
+ DisplayString,
+ espcAIHighTrapnum
+ Integer32,
+ espcAIHighClass
+ DisplayString,
+ espcAINormalActions
+ DisplayString,
+ espcAINormalTrapnum
+ Integer32,
+ espcAINormalClass
+ DisplayString,
+ espcAILowValue
+ DisplayString,
+ espcAILowActions
+ DisplayString,
+ espcAILowTrapnum
+ Integer32,
+ espcAILowClass
+ DisplayString,
+ espcAIVlowValue
+ DisplayString,
+ espcAIVlowActions
+ DisplayString,
+ espcAIVlowTrapnum
+ Integer32,
+ espcAIVlowClass
+ DisplayString,
+ espcAIConvUnitName
+ DisplayString,
+ espcAIConvHighValue
+ DisplayString,
+ espcAIConvHighUnit
+ DisplayString,
+ espcAIConvLowValue
+ DisplayString,
+ espcAIConvLowUnit
+ DisplayString,
+ espcAIDisplayFormat
+ DisplayString
+}
+
+
+ActionCallNumberConfig ::=
+ SEQUENCE {
+ actionCallNumberIndex
+ Integer32,
+ actionCallNumber
+ DisplayString
+
+}
+
+ActionPagerConfig ::=
+ SEQUENCE {
+ actionPagerIndex
+ Integer32,
+ actionPagerType
+ DisplayString,
+ actionPagerNumber
+ DisplayString,
+ actionPagerID
+ DisplayString,
+ actionPagerMessage
+ DisplayString,
+ actionPagerPostCalloutDelay
+ Integer32,
+ actionPagerPostIDDelay
+ Integer32
+}
+
+ESPointConfigOutput ::=
+ SEQUENCE {
+ espcOutputIndexES
+ Integer32,
+ espcOutputIndexPoint
+ Integer32,
+ espcOutputEnable
+ DisplayString,
+ espcOutputActiveState
+ DisplayString,
+ espcOutputType
+ DisplayString,
+ espcOutputAliasValue
+ DisplayString,
+ espcOutputAliasColor
+ DisplayString,
+ espcOutputActiveAlias
+ DisplayString,
+ espcOutputActiveColor
+ DisplayString,
+ espcOutputActiveActions
+ DisplayString,
+ espcOutputActiveTrapnum
+ Integer32,
+ espcOutputActiveClass
+ DisplayString,
+ espcOutputInactiveAlias
+ DisplayString,
+ espcOutputInactiveColor
+ DisplayString,
+ espcOutputInactiveActions
+ DisplayString,
+ espcOutputInactiveTrapnum
+ Integer32,
+ espcOutputInactiveClass
+ DisplayString
+}
+
+EventClassConfig ::=
+ SEQUENCE {
+ evClassNameIndex
+ Integer32,
+ evClassName
+ DisplayString
+}
+
+RTSFileConfig ::=
+ SEQUENCE {
+ rtsFileIndex
+ Integer32,
+ rtsFileMode
+ DisplayString,
+ rtsFileShowAnswer
+ DisplayString,
+ rtsFileReqXON
+ DisplayString,
+ rtsFileTimeout
+ Integer32,
+ rtsFileEmptyClose
+ DisplayString,
+ rtsFilePushHost
+ DisplayString,
+ rtsFilePushPort
+ Integer32,
+ rtsFilePushRetryTimer
+ Integer32
+}
+
+
+ModemCLIDLogConfig ::=
+ SEQUENCE {
+ modemCLIDLogIndex
+ Integer32,
+ modemCLIDLogNumber
+ DisplayString
+}
+
+
+PowerDistribOutputCurrent ::=
+ SEQUENCE {
+ pdOutputCurrentIndex
+ Integer32,
+ pdOutputCurrentInEventState
+ DisplayString,
+ pdOutputCurrentValue
+ Integer32,
+ pdOutputCurrentValueStr
+ DisplayString,
+ pdOutputCurrentDeadband
+ Integer32,
+ pdOutputCurrentVHighCurrent
+ Integer32,
+ pdOutputCurrentHighCurrent
+ Integer32,
+ pdOutputCurrentLowCurrent
+ Integer32,
+ pdOutputCurrentVLowCurrent
+ Integer32
+}
+
+PowerDistribOutputFuse ::=
+ SEQUENCE {
+ pdOutputFuseIndex
+ Integer32,
+ pdOutputFuseInEventState
+ DisplayString,
+ pdOutputFuseValueStr
+ DisplayString
+}
+
+PowerDistribNextGen ::=
+ SEQUENCE {
+ pdnIndexPD
+ Integer32,
+ pdnIndexOutput
+ Integer32,
+ pdnConfig
+ DisplayString,
+ pdnMainCurrentInEventState
+ DisplayString,
+ pdnMainCurrentValue
+ Integer32,
+ pdnMainCurrentValueStr
+ DisplayString,
+ pdnMainCurrentDeadband
+ Integer32,
+ pdnMainCurrentVHighCurrent
+ Integer32,
+ pdnMainCurrentHighCurrent
+ Integer32,
+ pdnMainCurrentLowCurrent
+ Integer32,
+ pdnMainCurrentVLowCurrent
+ Integer32,
+ pdnMainVoltageInEventState
+ DisplayString,
+ pdnMainVoltageValue
+ Integer32,
+ pdnMainVoltageValueStr
+ DisplayString,
+ pdnMainVoltageDeadband
+ Integer32,
+ pdnMainVoltageVHighVoltage
+ Integer32,
+ pdnMainVoltageHighVoltage
+ Integer32,
+ pdnMainVoltageLowVoltage
+ Integer32,
+ pdnMainVoltageVLowVoltage
+ Integer32,
+ pdnMainPowerValue
+ Integer32,
+ pdnMainPowerValueStr
+ DisplayString,
+ pdnOutputCurrentInEventState
+ DisplayString,
+ pdnOutputCurrentValue
+ Integer32,
+ pdnOutputCurrentValueStr
+ DisplayString,
+ pdnOutputCurrentDeadband
+ Integer32,
+ pdnOutputCurrentVHighCurrent
+ Integer32,
+ pdnOutputCurrentHighCurrent
+ Integer32,
+ pdnOutputCurrentLowCurrent
+ Integer32,
+ pdnOutputCurrentVLowCurrent
+ Integer32,
+ pdnOutputFuseInEventState
+ DisplayString,
+ pdnOutputFuseValueStr
+ DisplayString,
+ pdnMainCombinedStatus
+ DisplayString,
+ pdnOutputCombinedStatusBlock1
+ DisplayString,
+ pdnOutputCombinedStatusBlock2
+ DisplayString,
+ pdnDeviceCurrentValue
+ Integer32,
+ pdnDeviceCurrentValueStr
+ DisplayString
+}
+
+CPEConfig ::=
+ SEQUENCE {
+ cpeIndex
+ Integer32,
+ cpeHost
+ DisplayString,
+ cpeName
+ DisplayString,
+ cpeDescription
+ DisplayString,
+ cpeKeepalive
+ Integer32,
+ cpeThreshold
+ Integer32,
+ cpeEventReminderInterval
+ Integer32,
+ cpeKeepaliveTicks
+ Integer32,
+ cpePingSize
+ Integer32,
+ cpeInfoReset
+ Integer32,
+ cpeInfoNumReq
+ Integer32,
+ cpeInfoNumGoodResp
+ Integer32,
+ cpeInfoNumBadResp
+ Integer32,
+ cpeInfoNumLostResp
+ Integer32,
+ cpeInfoPercentLoss
+ DisplayString,
+ cpeInfoPercentBad
+ DisplayString
+}
+
+ScriptingConfig ::=
+ SEQUENCE {
+ scrIndex
+ Integer32,
+ scrEnable
+ DisplayString,
+ scrName
+ DisplayString,
+ scrFilename
+ DisplayString,
+ scrRunAlways
+ DisplayString,
+ scrRunAtStartup
+ DisplayString,
+ scrRunScheduled
+ DisplayString,
+ scrScheduleTime
+ DisplayString,
+ scrArguments
+ DisplayString,
+ scrRepeatInterval
+ Integer32
+}
+
+ScriptingDTRCtrlPortEnableConfig ::=
+ SEQUENCE {
+ scrDTRCtrlPortEnableIndex
+ Integer32,
+ scrDTRCtrlPortEnable
+ DisplayString
+
+}
+
+ScriptingVolatileString ::=
+ SEQUENCE {
+ scrVolatileStringIndex
+ Integer32,
+ scrVolatileString
+ DisplayString
+}
+
+ScriptingVolatileInt ::=
+ SEQUENCE {
+ scrVolatileIntIndex
+ Integer32,
+ scrVolatileInt
+ Integer32
+}
+
+ScriptingNonVolatileString ::=
+ SEQUENCE {
+ scrNonVolatileStringIndex
+ Integer32,
+ scrNonVolatileString
+ DisplayString
+}
+
+ScriptingNonVolatileInt ::=
+ SEQUENCE {
+ scrNonVolatileIntIndex
+ Integer32,
+ scrNonVolatileInt
+ Integer32
+}
+
+CRDBFileEnforceMinConfig ::=
+ SEQUENCE {
+ sysCRDBFileEnforceMinIndex
+ Integer32,
+ sysCRDBFileEnforceMin
+ DisplayString
+}
+
+CRDBFileIDConfig ::=
+ SEQUENCE {
+ sysCRDBFileIDIndex
+ Integer32,
+ sysCRDBFileID
+ DisplayString
+}
+
+NetworkTimeHostConfig ::=
+ SEQUENCE {
+ sysTimeNetHostIndex
+ Integer32,
+ sysTimeNetHost
+ DisplayString
+}
+
+ActionHostConfig ::=
+ SEQUENCE {
+ actionHostIndex
+ Integer32,
+ actionHost
+ DisplayString
+}
+
+ActionEmailConfig ::=
+ SEQUENCE {
+ actionEmailIndex
+ Integer32,
+ actionEmail
+ DisplayString
+}
+
+FileEnforceMinimumConfig ::=
+ SEQUENCE {
+ sysCRDBFileEnforceMinIndex
+ Integer32,
+ sysCRDBFileEnforceMin
+ DisplayString
+}
+
+SerialHandshakingLowEventConfig ::=
+ SEQUENCE {
+ evShskLowIndex
+ Integer32,
+ evShskLowEnable
+ DisplayString,
+ evShskLowActions
+ DisplayString,
+ evShskLowMessage
+ DisplayString,
+ evShskLowClass
+ DisplayString,
+ evShskLowTrapNum
+ Integer32
+}
+
+SerialHandshakingHighEventConfig ::=
+ SEQUENCE {
+ evShskHighIndex
+ Integer32,
+ evShskHighEnable
+ DisplayString,
+ evShskHighActions
+ DisplayString,
+ evShskHighMessage
+ DisplayString,
+ evShskHighClass
+ DisplayString,
+ evShskHighTrapNum
+ Integer32
+}
+
+NoDataEvent1PortEnableConfig ::=
+ SEQUENCE {
+ evNoData1PortEnableIndex
+ Integer32,
+ evNoData1PortEnable
+ DisplayString
+}
+
+NoDataEvent2PortEnableConfig ::=
+ SEQUENCE {
+ evNoData2PortEnableIndex
+ Integer32,
+ evNoData2PortEnable
+ DisplayString
+}
+
+DataEventMacroConfig ::=
+ SEQUENCE {
+ evdMacroIndex
+ Integer32,
+ evdMacroName
+ DisplayString,
+ evdMacroEquation
+ DisplayString
+}
+
+DataEventFieldConfig ::=
+ SEQUENCE {
+ evdFieldIndex
+ Integer32,
+ evdFieldStart
+ Integer32,
+ evdFieldLength
+ Integer32,
+ evdFieldName
+ DisplayString,
+ evdFieldLine
+ Integer32,
+ evdFieldType
+ DisplayString
+}
+
+DataEventConfig ::=
+ SEQUENCE {
+ evdIndex
+ Integer32,
+ evdEnable
+ DisplayString,
+ evdName
+ DisplayString,
+ evdEquation
+ DisplayString,
+ evdThreshold
+ Integer32,
+ evdAutoClear
+ DisplayString,
+ evdClearInterval
+ DisplayString,
+ evdClearTime
+ DisplayString,
+ evdActions
+ DisplayString,
+ evdClass
+ DisplayString,
+ evdTrapNum
+ Integer32,
+ evdMode
+ DisplayString
+}
+
+SecUserConfig ::=
+ SEQUENCE {
+ secUserIndex
+ Integer32,
+ secUserEnable
+ DisplayString,
+ secUserConnectVia
+ DisplayString,
+ secUserLoginTo
+ DisplayString,
+ secUserAccessFile
+ DisplayString,
+ secUserPTEscapeTo
+ DisplayString,
+ secUserPPPType
+ DisplayString,
+ secUserRights
+ DisplayString,
+ secUserEventsReadAccess
+ DisplayString,
+ secUserAuditReadAccess
+ DisplayString,
+ secUserEventsWriteAccess
+ DisplayString,
+ secUserAuditWriteAccess
+ DisplayString,
+ secUserExpiration
+ DisplayString,
+ secUserCallbackNumber1
+ DisplayString,
+ secUserCallbackNumber2
+ DisplayString,
+ secUserCallbackNumber3
+ DisplayString,
+ secUserChallengeTelnetMode
+ DisplayString,
+ secUserChallengeModemMode
+ DisplayString,
+ secUserChallengeConsoleMode
+ DisplayString,
+ secUserChallengeTelnetSendTo
+ DisplayString,
+ secUserChallengeModemSendTo
+ DisplayString,
+ secUserChallengeExpiration
+ Integer32
+}
+
+
+
+
+ModemCLIDNumberConfig ::=
+ SEQUENCE {
+ modemCLIDNumberIndex
+ Integer32,
+ modemCLIDNumber
+ DisplayString
+}
+
+
+RouteTestConfig ::=
+ SEQUENCE {
+ routeTestAddressIndex
+ Integer32,
+ routeTestAddress
+ DisplayString
+}
+
+IPRestrictionConfig ::=
+ SEQUENCE {
+ ipRestrictionIndex
+ Integer32,
+ ipRestrictionEnable
+ DisplayString,
+ ipRestrictionMask
+ DisplayString
+}
+
+DNSConfig ::=
+ SEQUENCE {
+ dnsIndex
+ Integer32,
+ dnsAddress
+ IpAddress
+}
+
+HostConfig ::=
+ SEQUENCE {
+ hostIndex
+ Integer32,
+ hostDeclaration
+ DisplayString
+}
+
+SNMPPollRequestConfig ::=
+ SEQUENCE {
+ snmpPRequestIndex
+ Integer32,
+ snmpPRequestDescription
+ DisplayString,
+ snmpPRequestAgent
+ DisplayString,
+ snmpPRequestReadcom
+ DisplayString,
+ snmpPRequestOID
+ DisplayString,
+ snmpPRequestPeriod
+ Integer32,
+ snmpPRequestID
+ DisplayString,
+ snmpPRequestThreshold
+ DisplayString,
+ snmpPRequestResultStatus
+ DisplayString,
+ snmpPRequestResultValue
+ DisplayString,
+ snmpPRequestResultTime
+ DisplayString,
+ snmpPRequestResultType
+ DisplayString
+}
+
+FTPPushPushFileConfig ::=
+ SEQUENCE {
+ ftpPushPushFileIndex
+ Integer32,
+ ftpPushPushFile
+ DisplayString
+}
+
+FTPPushRemoteFileConfig ::=
+ SEQUENCE {
+ ftpPushRemoteFileIndex
+ Integer32,
+ ftpPushRemoteFileName
+ DisplayString
+}
+
+PortConfig ::=
+ SEQUENCE {
+ portConfigIndex
+ Integer32,
+ portConfigBaud
+ Integer32,
+ portConfigDataFormat
+ Integer32,
+ portConfigStripPtOutputLfs
+ Integer32,
+ portConfigStripPtInputLfs
+ Integer32,
+ portConfigMaskEnable
+ Integer32,
+ portConfigDAEnable
+ Integer32,
+ portConfigStoreAlarmsDPT
+ DisplayString,
+ portConfigRecordTimeout
+ Integer32,
+ portConfigDataType
+ DisplayString,
+ portConfigEtxToCRLF
+ DisplayString,
+ portConfigMLREnable
+ DisplayString,
+ portConfigMLRStartField1Pos
+ Integer32,
+ portConfigMLRStartField1Text
+ DisplayString,
+ portConfigMLRStartField2Pos
+ Integer32,
+ portConfigMLRStartField2Text
+ DisplayString,
+ portConfigMLRNumLinesBefore
+ Integer32,
+ portConfigMLREndDetection
+ DisplayString,
+ portConfigMLRLineCount
+ Integer32,
+ portConfigMLREndField1Pos
+ Integer32,
+ portConfigMLREndField1Text
+ DisplayString,
+ portConfigMLREndField2Pos
+ Integer32,
+ portConfigMLREndField2Text
+ DisplayString,
+ portConfigMLRUseComplexRules
+ DisplayString,
+ portConfigBufferPT
+ DisplayString,
+ portConfigId
+ DisplayString,
+ portConfigMode
+ DisplayString,
+ portConfigHsk
+ DisplayString
+
+}
+
+ESPoint ::=
+ SEQUENCE {
+ esIndexES
+ Integer32,
+ esIndexPC
+ Integer32,
+ esIndexPoint
+ Integer32,
+ esPointName
+ DisplayString,
+ esPointInEventState
+ Integer32,
+ esPointValueInt
+ Integer32,
+ esPointValueStr
+ DisplayString,
+ esPointTimeLastChange
+ DisplayString,
+ esPointTimetickLastChange
+ TimeTicks
+}
+
+ESExist ::=
+ SEQUENCE {
+ esIndex
+ Integer32,
+ esName
+ DisplayString,
+ esID
+ DisplayString,
+ esNumberTempSensors
+ Integer32,
+ esTempReportingMode
+ DisplayString,
+ esNumberCCs
+ Integer32,
+ esCCReportingMode
+ DisplayString,
+ esNumberHumidSensors
+ Integer32,
+ esHumidReportingMode
+ DisplayString,
+ esNumberNoiseSensors
+ Integer32,
+ esNoiseReportingMode
+ DisplayString,
+ esNumberAirflowSensors
+ Integer32,
+ esAirflowReportingMode
+ DisplayString,
+ esNumberAnalog
+ Integer32,
+ esAnalogReportingMode
+ DisplayString,
+ esNumberOutputs
+ Integer32,
+ esOutputReportingMode
+ DisplayString,
+ esTempCombinedStatus
+ DisplayString,
+ esCCCombinedStatusBlock1
+ DisplayString,
+ esCCCombinedStatusBlock2
+ DisplayString,
+ esCCCombinedStatusBlock3
+ DisplayString,
+ esCCCombinedStatusBlock4
+ DisplayString,
+ esCCCombinedStatusBlock5
+ DisplayString,
+ esCCCombinedStatusBlock6
+ DisplayString,
+ esCCCombinedStatusBlock7
+ DisplayString,
+ esCCCombinedStatusBlock8
+ DisplayString,
+ esHumidCombinedStatus
+ DisplayString,
+ esAnalogCombinedStatusBlock1
+ DisplayString,
+ esAnalogCombinedStatusBlock2
+ DisplayString,
+ esAnalogCombinedStatusBlock3
+ DisplayString,
+ esAnalogCombinedStatusBlock4
+ DisplayString,
+ esAnalogCombinedStatusBlock5
+ DisplayString,
+ esAnalogCombinedStatusBlock6
+ DisplayString,
+ esOutputCombinedStatusBlock1
+ DisplayString,
+ esOutputCombinedStatusBlock2
+ DisplayString
+}
+
+DEStatus ::=
+ SEQUENCE {
+ deStatusIndex
+ Integer32,
+ deStatusName
+ DisplayString,
+ deStatusCounter
+ Integer32,
+ deStatusThreshold
+ Integer32
+}
+
+AISGALD ::=
+ SEQUENCE {
+ aisgsALDIndex
+ Integer32,
+ aisgsALDSectorID
+ DisplayString,
+ aisgsALDType
+ DisplayString,
+ aisgsALDDescription
+ DisplayString,
+ aisgsALDStatus
+ DisplayString,
+ aisgsALDID
+ DisplayString,
+ aisgsALDTilt
+ DisplayString,
+ aisgsALDHwVersion
+ DisplayString,
+ aisgsALDSwVersion
+ DisplayString,
+ aisgsALDModel
+ DisplayString,
+ aisgsALDAntennaModel
+ DisplayString,
+ aisgsALDMinTilt
+ DisplayString,
+ aisgsALDMaxTilt
+ DisplayString,
+ aisgsALDAISGVersion
+ DisplayString
+}
+
+AISGFile ::=
+ SEQUENCE {
+ aisgsFileIndex
+ Integer32,
+ aisgsFileName
+ DisplayString,
+ aisgsFileType
+ DisplayString,
+ aisgsFileVersion
+ DisplayString
+}
+
+AISGAuto ::=
+ SEQUENCE {
+ aisgsAutoIndex
+ Integer32,
+ aisgsAutoVendor
+ DisplayString,
+ aisgsAutoALDModel
+ DisplayString,
+ aisgsAutoSoftware
+ DisplayString,
+ aisgsAutoConfig
+ DisplayString,
+ aisgsAutoTilt
+ DisplayString
+}
+
+AISGAAA ::=
+ SEQUENCE {
+ aisgsAAAIndex
+ Integer32,
+ aisgsAAAALDID
+ DisplayString,
+ aisgsAAAAntennaSN
+ DisplayString,
+ aisgsAAASectorID
+ DisplayString
+}
+
+FSStatus ::=
+ SEQUENCE {
+ fsStatusIndex
+ Integer32,
+ fsStatusName
+ DisplayString,
+ fsStatusDeviceState
+ DisplayString,
+ fsStatusVolumeValueString
+ DisplayString,
+ fsStatusVolumePercentLevel
+ DisplayString,
+ fsStatusVolumeInEventState
+ DisplayString,
+ fsStatusCombined
+ DisplayString
+}
+
+ACPMStatus ::=
+ SEQUENCE {
+ acpmsIndex
+ Integer32,
+ acpmsName
+ DisplayString,
+ acpmsAvgVoltageValueStr
+ DisplayString,
+ acpmsAvgVoltageMinStr
+ DisplayString,
+ acpmsAvgVoltageMaxStr
+ DisplayString,
+ acpmsAvgVoltageAvgStr
+ DisplayString,
+ acpmsAvgVoltageInEventState
+ DisplayString,
+ acpmsVoltagePhaseAValueStr
+ DisplayString,
+ acpmsVoltagePhaseBValueStr
+ DisplayString,
+ acpmsVoltagePhaseCValueStr
+ DisplayString,
+ acpmsAvgCurrentValueStr
+ DisplayString,
+ acpmsAvgCurrentMinStr
+ DisplayString,
+ acpmsAvgCurrentMaxStr
+ DisplayString,
+ acpmsAvgCurrentAvgStr
+ DisplayString,
+ acpmsAvgCurrentInEventState
+ DisplayString,
+ acpmsCurrentPhaseAValueStr
+ DisplayString,
+ acpmsCurrentPhaseBValueStr
+ DisplayString,
+ acpmsCurrentPhaseCValueStr
+ DisplayString,
+ acpmsAvgFreqValueStr
+ DisplayString,
+ acpmsAvgFreqMinStr
+ DisplayString,
+ acpmsAvgFreqMaxStr
+ DisplayString,
+ acpmsAvgFreqAvgStr
+ DisplayString,
+ acpmsAvgFreqInEventState
+ DisplayString,
+ acpmsTRPValueStr
+ DisplayString,
+ acpmsTRPMinStr
+ DisplayString,
+ acpmsTRPMaxStr
+ DisplayString,
+ acpmsTRPAvgStr
+ DisplayString,
+ acpmsTRPInEventState
+ DisplayString,
+ acpmsRPPhaseAValueStr
+ DisplayString,
+ acpmsRPPhaseBValueStr
+ DisplayString,
+ acpmsRPPhaseCValueStr
+ DisplayString,
+ acpmsCombined
+ DisplayString,
+ acpmsTPFValueStr
+ DisplayString,
+ acpmsTPFMinStr
+ DisplayString,
+ acpmsTPFMaxStr
+ DisplayString,
+ acpmsTPFAvgStr
+ DisplayString,
+ acpmsTPFInEventState
+ DisplayString,
+ acpmsPFPhaseAValueStr
+ DisplayString,
+ acpmsPFPhaseBValueStr
+ DisplayString,
+ acpmsPFPhaseCValueStr
+ DisplayString,
+ acpmsTRcPValueStr
+ DisplayString,
+ acpmsTRcPMinStr
+ DisplayString,
+ acpmsTRcPMaxStr
+ DisplayString,
+ acpmsTRcPAvgStr
+ DisplayString,
+ acpmsRcPPhaseAValueStr
+ DisplayString,
+ acpmsRcPPhaseBValueStr
+ DisplayString,
+ acpmsRcPPhaseCValueStr
+ DisplayString,
+ acpmsTAPValueStr
+ DisplayString,
+ acpmsTAPMinStr
+ DisplayString,
+ acpmsTAPMaxStr
+ DisplayString,
+ acpmsTAPAvgStr
+ DisplayString,
+ acpmsAPPhaseAValueStr
+ DisplayString,
+ acpmsAPPhaseBValueStr
+ DisplayString,
+ acpmsAPPhaseCValueStr
+ DisplayString,
+ acpmsTotalEnergyWh
+ Integer32,
+ acpmsTotalEnergyVAR
+ Integer32,
+ acpmsTotalEnergyVA
+ Integer32
+}
+
+FuelSensorConfigGeneral ::=
+ SEQUENCE {
+ fsGenIndex
+ Integer32,
+ fsGenName
+ DisplayString,
+ fsGenSensorType
+ DisplayString,
+ fsGenDistanceUnit
+ DisplayString,
+ fsGenRawValueTop
+ DisplayString,
+ fsGenTopOffset
+ DisplayString,
+ fsGenRawValueBottom
+ DisplayString,
+ fsGenBottomOffset
+ DisplayString,
+ fsGenInputES
+ Integer32,
+ fsGenInputPoint
+ Integer32,
+ fsGenFilterAveraging
+ Integer32,
+ fsGenSysrepEnable
+ DisplayString,
+ fsGenSysrepThreshold
+ DisplayString,
+ fsGenSysrepLimit
+ Integer32,
+ fsGenSysrepPackage
+ Integer32,
+ fsGenSysrepType
+ DisplayString,
+ fsGenEnable
+ DisplayString
+}
+
+FuelSensorConfigTank ::=
+ SEQUENCE {
+ fsTankIndex
+ Integer32,
+ fsTankHeight
+ DisplayString,
+ fsTankDimA
+ DisplayString,
+ fsTankDimB
+ DisplayString,
+ fsTankVolume
+ DisplayString,
+ fsTankVolumeUnit
+ DisplayString,
+ fsTankShape
+ DisplayString
+}
+
+FuelSensorConfigCustomTankStrapping ::=
+ SEQUENCE {
+ fsCustomTankIndexFS
+ Integer32,
+ fsCustomTankIndexDatum
+ Integer32,
+ fsCustomTankHeight
+ DisplayString,
+ fsCustomTankVolume
+ DisplayString
+}
+
+FuelSensorConfigVolume ::=
+ SEQUENCE {
+ fsVolumeIndex
+ Integer32,
+ fsVolumeEnable
+ DisplayString,
+ fsVolumeDeadband
+ DisplayString,
+ fsVolumeVHighValue
+ DisplayString,
+ fsVolumeVHighActions
+ DisplayString,
+ fsVolumeVHighTrapNum
+ Integer32,
+ fsVolumeVHighClass
+ DisplayString,
+ fsVolumeHighValue
+ DisplayString,
+ fsVolumeHighActions
+ DisplayString,
+ fsVolumeHighTrapNum
+ Integer32,
+ fsVolumeHighClass
+ DisplayString,
+ fsVolumeNormalActions
+ DisplayString,
+ fsVolumeNormalTrapNum
+ Integer32,
+ fsVolumeNormalClass
+ DisplayString,
+ fsVolumeLowValue
+ DisplayString,
+ fsVolumeLowActions
+ DisplayString,
+ fsVolumeLowTrapNum
+ Integer32,
+ fsVolumeLowClass
+ DisplayString,
+ fsVolumeVLowValue
+ DisplayString,
+ fsVolumeVLowActions
+ DisplayString,
+ fsVolumeVLowTrapNum
+ Integer32,
+ fsVolumeVLowClass
+ DisplayString
+}
+
+FuelSensorConfigDisconnect ::=
+ SEQUENCE {
+ fsDiscIndex
+ Integer32,
+ fsDiscEnable
+ DisplayString,
+ fsDiscHighValue
+ DisplayString,
+ fsDiscLowValue
+ DisplayString,
+ fsDiscActions
+ DisplayString,
+ fsDiscTrapNum
+ Integer32,
+ fsDiscClass
+ DisplayString,
+ fsDiscNormalActions
+ DisplayString,
+ fsDiscNormalTrapNum
+ Integer32,
+ fsDiscNormalClass
+ DisplayString
+}
+
+ACPMConfigGeneral ::=
+ SEQUENCE {
+ acpmGenIndex
+ Integer32,
+ acpmGenDevice
+ DisplayString,
+ acpmGenName
+ DisplayString,
+ acpmGenAddress
+ Integer32,
+ acpmGenPtRatio
+ Integer32,
+ acpmGenCtRatio
+ Integer32,
+ acpmGenPowerType
+ DisplayString,
+ acpmGenSysrepPackage
+ Integer32,
+ acpmGenSysrepType
+ DisplayString,
+ acpmGenEnable
+ DisplayString
+}
+
+ACPMConfigAvgVoltage ::=
+ SEQUENCE {
+ acpmAvgVoltageIndex
+ Integer32,
+ acpmAvgVoltageEnable
+ DisplayString,
+ acpmAvgVoltageDeadband
+ DisplayString,
+ acpmAvgVoltageVHighValue
+ DisplayString,
+ acpmAvgVoltageVHighActions
+ DisplayString,
+ acpmAvgVoltageVHighTrapNum
+ Integer32,
+ acpmAvgVoltageVHighClass
+ DisplayString,
+ acpmAvgVoltageHighValue
+ DisplayString,
+ acpmAvgVoltageHighActions
+ DisplayString,
+ acpmAvgVoltageHighTrapNum
+ Integer32,
+ acpmAvgVoltageHighClass
+ DisplayString,
+ acpmAvgVoltageNormalActions
+ DisplayString,
+ acpmAvgVoltageNormalTrapNum
+ Integer32,
+ acpmAvgVoltageNormalClass
+ DisplayString,
+ acpmAvgVoltageLowValue
+ DisplayString,
+ acpmAvgVoltageLowActions
+ DisplayString,
+ acpmAvgVoltageLowTrapNum
+ Integer32,
+ acpmAvgVoltageLowClass
+ DisplayString,
+ acpmAvgVoltageVLowValue
+ DisplayString,
+ acpmAvgVoltageVLowActions
+ DisplayString,
+ acpmAvgVoltageVLowTrapNum
+ Integer32,
+ acpmAvgVoltageVLowClass
+ DisplayString,
+ acpmAvgVoltageSysrepEnable
+ DisplayString,
+ acpmAvgVoltageSysrepThreshold
+ DisplayString,
+ acpmAvgVoltageSysrepLimit
+ Integer32
+}
+
+ACPMConfigAvgCurrent ::=
+ SEQUENCE {
+ acpmAvgCurrentIndex
+ Integer32,
+ acpmAvgCurrentEnable
+ DisplayString,
+ acpmAvgCurrentDeadband
+ DisplayString,
+ acpmAvgCurrentVHighValue
+ DisplayString,
+ acpmAvgCurrentVHighActions
+ DisplayString,
+ acpmAvgCurrentVHighTrapNum
+ Integer32,
+ acpmAvgCurrentVHighClass
+ DisplayString,
+ acpmAvgCurrentHighValue
+ DisplayString,
+ acpmAvgCurrentHighActions
+ DisplayString,
+ acpmAvgCurrentHighTrapNum
+ Integer32,
+ acpmAvgCurrentHighClass
+ DisplayString,
+ acpmAvgCurrentNormalActions
+ DisplayString,
+ acpmAvgCurrentNormalTrapNum
+ Integer32,
+ acpmAvgCurrentNormalClass
+ DisplayString,
+ acpmAvgCurrentLowValue
+ DisplayString,
+ acpmAvgCurrentLowActions
+ DisplayString,
+ acpmAvgCurrentLowTrapNum
+ Integer32,
+ acpmAvgCurrentLowClass
+ DisplayString,
+ acpmAvgCurrentVLowValue
+ DisplayString,
+ acpmAvgCurrentVLowActions
+ DisplayString,
+ acpmAvgCurrentVLowTrapNum
+ Integer32,
+ acpmAvgCurrentVLowClass
+ DisplayString,
+ acpmAvgCurrentSysrepEnable
+ DisplayString,
+ acpmAvgCurrentSysrepThreshold
+ DisplayString,
+ acpmAvgCurrentSysrepLimit
+ Integer32
+}
+
+ACPMConfigFreq ::=
+ SEQUENCE {
+ acpmFreqIndex
+ Integer32,
+ acpmFreqEnable
+ DisplayString,
+ acpmFreqDeadband
+ DisplayString,
+ acpmFreqVHighValue
+ DisplayString,
+ acpmFreqVHighActions
+ DisplayString,
+ acpmFreqVHighTrapNum
+ Integer32,
+ acpmFreqVHighClass
+ DisplayString,
+ acpmFreqHighValue
+ DisplayString,
+ acpmFreqHighActions
+ DisplayString,
+ acpmFreqHighTrapNum
+ Integer32,
+ acpmFreqHighClass
+ DisplayString,
+ acpmFreqNormalActions
+ DisplayString,
+ acpmFreqNormalTrapNum
+ Integer32,
+ acpmFreqNormalClass
+ DisplayString,
+ acpmFreqLowValue
+ DisplayString,
+ acpmFreqLowActions
+ DisplayString,
+ acpmFreqLowTrapNum
+ Integer32,
+ acpmFreqLowClass
+ DisplayString,
+ acpmFreqVLowValue
+ DisplayString,
+ acpmFreqVLowActions
+ DisplayString,
+ acpmFreqVLowTrapNum
+ Integer32,
+ acpmFreqVLowClass
+ DisplayString,
+ acpmFreqSysrepEnable
+ DisplayString,
+ acpmFreqSysrepThreshold
+ DisplayString,
+ acpmFreqSysrepLimit
+ Integer32
+}
+
+ACPMConfigTRP ::=
+ SEQUENCE {
+ acpmTRPIndex
+ Integer32,
+ acpmTRPEnable
+ DisplayString,
+ acpmTRPDeadband
+ DisplayString,
+ acpmTRPVHighValue
+ DisplayString,
+ acpmTRPVHighActions
+ DisplayString,
+ acpmTRPVHighTrapNum
+ Integer32,
+ acpmTRPVHighClass
+ DisplayString,
+ acpmTRPHighValue
+ DisplayString,
+ acpmTRPHighActions
+ DisplayString,
+ acpmTRPHighTrapNum
+ Integer32,
+ acpmTRPHighClass
+ DisplayString,
+ acpmTRPNormalActions
+ DisplayString,
+ acpmTRPNormalTrapNum
+ Integer32,
+ acpmTRPNormalClass
+ DisplayString,
+ acpmTRPLowValue
+ DisplayString,
+ acpmTRPLowActions
+ DisplayString,
+ acpmTRPLowTrapNum
+ Integer32,
+ acpmTRPLowClass
+ DisplayString,
+ acpmTRPVLowValue
+ DisplayString,
+ acpmTRPVLowActions
+ DisplayString,
+ acpmTRPVLowTrapNum
+ Integer32,
+ acpmTRPVLowClass
+ DisplayString,
+ acpmTRPSysrepEnable
+ DisplayString,
+ acpmTRPSysrepThreshold
+ DisplayString,
+ acpmTRPSysrepLimit
+ Integer32
+}
+
+ACPMConfigDisconnect ::=
+ SEQUENCE {
+ acpmDisconnectIndex
+ Integer32,
+ acpmDisconnectEnable
+ DisplayString,
+ acpmDisconnectActions
+ DisplayString,
+ acpmDisconnectTrapNum
+ Integer32,
+ acpmDisconnectClass
+ DisplayString,
+ acpmDisconnectNormalActions
+ DisplayString,
+ acpmDisconnectNormalTrapNum
+ Integer32,
+ acpmDisconnectNormalClass
+ DisplayString
+}
+
+ACPMConfigTotalPowerFactor ::=
+ SEQUENCE {
+ acpmTPFIndex
+ Integer32,
+ acpmTPFEnable
+ DisplayString,
+ acpmTPFDeadband
+ DisplayString,
+ acpmTPFNormalActions
+ DisplayString,
+ acpmTPFNormalTrapNum
+ Integer32,
+ acpmTPFNormalClass
+ DisplayString,
+ acpmTPFLowValue
+ DisplayString,
+ acpmTPFLowActions
+ DisplayString,
+ acpmTPFLowTrapNum
+ Integer32,
+ acpmTPFLowClass
+ DisplayString,
+ acpmTPFVLowValue
+ DisplayString,
+ acpmTPFVLowActions
+ DisplayString,
+ acpmTPFVLowTrapNum
+ Integer32,
+ acpmTPFVLowClass
+ DisplayString,
+ acpmTPFSysrepEnable
+ DisplayString,
+ acpmTPFSysrepThreshold
+ DisplayString,
+ acpmTPFSysrepLimit
+ Integer32
+}
+
+
+--***************************************************************************************
+--TRAP DEFINITIONS
+--***************************************************************************************
+
+s571StockContactClosureTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock contact closure trap is issued when a contact closure
+ event happens."
+ ::= { s571 110 }
+
+s571StockTempTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock temperature trap is issued when a temperature event
+ happens."
+ ::= { s571 120 }
+
+s571StockHumidityTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock humidity trap is issued when a humidity event
+ happens."
+ ::= { s571 130 }
+
+s571StockAnalogTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when an analog sensor event
+ happens."
+ ::= { s571 140 }
+
+s571StockOutputTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock output trap is issued when an output event
+ happens. That is, depending on the configuration,
+ when an output changes state for any reason, this
+ trap will be sent."
+ ::= { s571 150 }
+
+s571StockPDCurrentTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ current event happens."
+ ::= { s571 180 }
+
+s571StockPDVoltageTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ voltage event happens."
+ ::= { s571 190 }
+
+s571StockPDFuseTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock analog trap is issued when a power distribution
+ fuse event happens."
+ ::= { s571 210 }
+
+s571StockDataAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock data alarm trap is issued when a
+ data alarm happens."
+ ::= { s571 503 }
+
+s571StockNoDataAlarmTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock no-data alarm trap is issued when
+ the unit has received no data for a configured
+ interval within a configured schedule."
+ ::= { s571 505 }
+
+s571StockSchedTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock scheduled alarm trap is issued
+ when the current time reaches the scheduled
+ alarm time."
+ ::= { s571 506 }
+
+s571StockImmediateTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "The stock immediate alarm trap is issued
+ when the user enters the DOTRAP command."
+ ::= { s571 507 }
+
+s571StockCTSTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock CTS trap is issued when an RS-232 CTS event
+ happens."
+ ::= { s571 510 }
+
+s571CPEDownTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock CPE Down trap is issued when a CPE Down event
+ happens."
+ ::= { s571 511 }
+
+s571FuelSensorDisconnectTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Disconnect trap is issued when a Fuel
+ Sensor Disconnect or Connect (Return to Normal) event happens."
+ ::= { s571 515 }
+
+s571FuelSensorVolumeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume trap is issued when a Fuel
+ Sensor Volume event happens"
+ ::= { s571 519 }
+
+s571ACPowerMonitorAvgVoltageTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor average voltage trap is issued when an
+ AC power monitor average voltage event happens."
+ ::= { s571 520 }
+
+s571ACPowerMonitorAvgCurrentTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor average current trap is issued when an
+ AC power monitor average current event happens."
+ ::= { s571 521 }
+
+s571ACPowerMonitorFrequencyTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor frequency trap is issued when an
+ AC power monitor frequency event happens."
+ ::= { s571 522 }
+
+s571ACPowerMonitorTRPTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor TRP (total real power) trap is issued
+ when an AC power monitor TRP event happens."
+ ::= { s571 523 }
+
+s571ACPowerMonitorDisconnectTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor disconnect trap is issued
+ when an AC power monitor disconnect event happens."
+ ::= { s571 524 }
+
+s571StockLoadSheddingTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Load Shedding trap is issued when a Load Shedding event
+ happens."
+ ::= { s571 525 }
+
+s571StockScriptTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock script trap is issued when a script triggers
+ an event via a_lib.PostEvent() called with no trap
+ number (or this trap number) specified."
+ ::= { s571 526 }
+
+s571FuelSensorVolumeSuddenChangeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume Sudden Change trap is issued
+ when a Fuel Sensor Volume Sudden Change event happens"
+ ::= { s571 527 }
+
+s571FuelSensorVolumeSlowChangeTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock Fuel Sensor Volume Slow Change trap is issued
+ when a Fuel Sensor Volume Slow Change event happens"
+ ::= { s571 528 }
+
+s571ACTotalPowerFactorTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock AC power monitor total power factor trap is issued
+ when an AC power monitor total power factor event happens."
+ ::= { s571 540 }
+
+s571ResetTrap NOTIFICATION-TYPE
+ OBJECTS { siteName, stockTrapString, trapTypeString }
+ STATUS current
+ DESCRIPTION
+ "A stock reset trap is issued when a reset event happens."
+ ::= { s571 543 }
+
+s571UserTrap1000 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1000."
+ ::= { s571 1000 }
+
+s571UserTrap1001 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1001."
+ ::= { s571 1001 }
+
+s571UserTrap1002 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1002."
+ ::= { s571 1002 }
+
+s571UserTrap1003 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1003."
+ ::= { s571 1003 }
+
+s571UserTrap1004 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1004."
+ ::= { s571 1004 }
+
+s571UserTrap1005 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1005."
+ ::= { s571 1005 }
+
+s571UserTrap1006 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1006."
+ ::= { s571 1006 }
+
+s571UserTrap1007 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1007."
+ ::= { s571 1007 }
+
+s571UserTrap1008 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1008."
+ ::= { s571 1008 }
+
+s571UserTrap1009 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1009."
+ ::= { s571 1009 }
+
+s571UserTrap1010 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1010."
+ ::= { s571 1010 }
+
+s571UserTrap1011 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1011."
+ ::= { s571 1011 }
+
+s571UserTrap1012 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1012."
+ ::= { s571 1012 }
+
+s571UserTrap1013 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1013."
+ ::= { s571 1013 }
+
+s571UserTrap1014 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1014."
+ ::= { s571 1014 }
+
+s571UserTrap1015 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1015."
+ ::= { s571 1015 }
+
+s571UserTrap1016 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1016."
+ ::= { s571 1016 }
+
+s571UserTrap1017 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1017."
+ ::= { s571 1017 }
+
+s571UserTrap1018 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1018."
+ ::= { s571 1018 }
+
+s571UserTrap1019 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1019."
+ ::= { s571 1019 }
+
+s571UserTrap1020 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1020."
+ ::= { s571 1020 }
+
+s571UserTrap1021 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1021."
+ ::= { s571 1021 }
+
+s571UserTrap1022 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1022."
+ ::= { s571 1022 }
+
+s571UserTrap1023 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1023."
+ ::= { s571 1023 }
+
+s571UserTrap1024 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1024."
+ ::= { s571 1024 }
+
+s571UserTrap1025 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1025."
+ ::= { s571 1025 }
+
+s571UserTrap1026 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1026."
+ ::= { s571 1026 }
+
+s571UserTrap1027 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1027."
+ ::= { s571 1027 }
+
+s571UserTrap1028 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1028."
+ ::= { s571 1028 }
+
+s571UserTrap1029 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1029."
+ ::= { s571 1029 }
+
+s571UserTrap1030 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1030."
+ ::= { s571 1030 }
+
+s571UserTrap1031 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1031."
+ ::= { s571 1031 }
+
+s571UserTrap1032 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1032."
+ ::= { s571 1032 }
+
+s571UserTrap1033 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1033."
+ ::= { s571 1033 }
+
+s571UserTrap1034 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1034."
+ ::= { s571 1034 }
+
+s571UserTrap1035 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1035."
+ ::= { s571 1035 }
+
+s571UserTrap1036 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1036."
+ ::= { s571 1036 }
+
+s571UserTrap1037 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1037."
+ ::= { s571 1037 }
+
+s571UserTrap1038 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1038."
+ ::= { s571 1038 }
+
+s571UserTrap1039 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1039."
+ ::= { s571 1039 }
+
+s571UserTrap1040 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1040."
+ ::= { s571 1040 }
+
+s571UserTrap1041 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1041."
+ ::= { s571 1041 }
+
+s571UserTrap1042 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1042."
+ ::= { s571 1042 }
+
+s571UserTrap1043 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1043."
+ ::= { s571 1043 }
+
+s571UserTrap1044 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1044."
+ ::= { s571 1044 }
+
+s571UserTrap1045 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1045."
+ ::= { s571 1045 }
+
+s571UserTrap1046 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1046."
+ ::= { s571 1046 }
+
+s571UserTrap1047 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1047."
+ ::= { s571 1047 }
+
+s571UserTrap1048 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1048."
+ ::= { s571 1048 }
+
+s571UserTrap1049 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1049."
+ ::= { s571 1049 }
+
+s571UserTrap1050 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1050."
+ ::= { s571 1050 }
+
+s571UserTrap1051 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1051."
+ ::= { s571 1051 }
+
+s571UserTrap1052 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1052."
+ ::= { s571 1052 }
+
+s571UserTrap1053 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1053."
+ ::= { s571 1053 }
+
+s571UserTrap1054 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1054."
+ ::= { s571 1054 }
+
+s571UserTrap1055 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1055."
+ ::= { s571 1055 }
+
+s571UserTrap1056 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1056."
+ ::= { s571 1056 }
+
+s571UserTrap1057 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1057."
+ ::= { s571 1057 }
+
+s571UserTrap1058 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1058."
+ ::= { s571 1058 }
+
+s571UserTrap1059 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1059."
+ ::= { s571 1059 }
+
+s571UserTrap1060 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1060."
+ ::= { s571 1060 }
+
+s571UserTrap1061 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1061."
+ ::= { s571 1061 }
+
+s571UserTrap1062 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1062."
+ ::= { s571 1062 }
+
+s571UserTrap1063 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1063."
+ ::= { s571 1063 }
+
+s571UserTrap1064 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1064."
+ ::= { s571 1064 }
+
+s571UserTrap1065 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1065."
+ ::= { s571 1065 }
+
+s571UserTrap1066 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1066."
+ ::= { s571 1066 }
+
+s571UserTrap1067 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1067."
+ ::= { s571 1067 }
+
+s571UserTrap1068 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1068."
+ ::= { s571 1068 }
+
+s571UserTrap1069 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1069."
+ ::= { s571 1069 }
+
+s571UserTrap1070 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1070."
+ ::= { s571 1070 }
+
+s571UserTrap1071 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1071."
+ ::= { s571 1071 }
+
+s571UserTrap1072 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1072."
+ ::= { s571 1072 }
+
+s571UserTrap1073 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1073."
+ ::= { s571 1073 }
+
+s571UserTrap1074 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1074."
+ ::= { s571 1074 }
+
+s571UserTrap1075 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1075."
+ ::= { s571 1075 }
+
+s571UserTrap1076 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1076."
+ ::= { s571 1076 }
+
+s571UserTrap1077 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1077."
+ ::= { s571 1077 }
+
+s571UserTrap1078 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1078."
+ ::= { s571 1078 }
+
+s571UserTrap1079 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1079."
+ ::= { s571 1079 }
+
+s571UserTrap1080 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1080."
+ ::= { s571 1080 }
+
+s571UserTrap1081 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1081."
+ ::= { s571 1081 }
+
+s571UserTrap1082 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1082."
+ ::= { s571 1082 }
+
+s571UserTrap1083 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1083."
+ ::= { s571 1083 }
+
+s571UserTrap1084 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1084."
+ ::= { s571 1084 }
+
+s571UserTrap1085 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1085."
+ ::= { s571 1085 }
+
+s571UserTrap1086 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1086."
+ ::= { s571 1086 }
+
+s571UserTrap1087 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1087."
+ ::= { s571 1087 }
+
+s571UserTrap1088 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1088."
+ ::= { s571 1088 }
+
+s571UserTrap1089 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1089."
+ ::= { s571 1089 }
+
+s571UserTrap1090 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1090."
+ ::= { s571 1090 }
+
+s571UserTrap1091 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1091."
+ ::= { s571 1091 }
+
+s571UserTrap1092 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1092."
+ ::= { s571 1092 }
+
+s571UserTrap1093 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1093."
+ ::= { s571 1093 }
+
+s571UserTrap1094 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1094."
+ ::= { s571 1094 }
+
+s571UserTrap1095 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1095."
+ ::= { s571 1095 }
+
+s571UserTrap1096 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1096."
+ ::= { s571 1096 }
+
+s571UserTrap1097 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1097."
+ ::= { s571 1097 }
+
+s571UserTrap1098 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1098."
+ ::= { s571 1098 }
+
+s571UserTrap1099 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1099."
+ ::= { s571 1099 }
+
+s571UserTrap1100 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1100."
+ ::= { s571 1100 }
+
+s571UserTrap1101 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1101."
+ ::= { s571 1101 }
+
+s571UserTrap1102 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1102."
+ ::= { s571 1102 }
+
+s571UserTrap1103 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1103."
+ ::= { s571 1103 }
+
+s571UserTrap1104 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1104."
+ ::= { s571 1104 }
+
+s571UserTrap1105 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1105."
+ ::= { s571 1105 }
+
+s571UserTrap1106 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1106."
+ ::= { s571 1106 }
+
+s571UserTrap1107 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1107."
+ ::= { s571 1107 }
+
+s571UserTrap1108 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1108."
+ ::= { s571 1108 }
+
+s571UserTrap1109 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1109."
+ ::= { s571 1109 }
+
+s571UserTrap1110 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1110."
+ ::= { s571 1110 }
+
+s571UserTrap1111 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1111."
+ ::= { s571 1111 }
+
+s571UserTrap1112 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1112."
+ ::= { s571 1112 }
+
+s571UserTrap1113 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1113."
+ ::= { s571 1113 }
+
+s571UserTrap1114 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1114."
+ ::= { s571 1114 }
+
+s571UserTrap1115 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1115."
+ ::= { s571 1115 }
+
+s571UserTrap1116 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1116."
+ ::= { s571 1116 }
+
+s571UserTrap1117 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1117."
+ ::= { s571 1117 }
+
+s571UserTrap1118 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1118."
+ ::= { s571 1118 }
+
+s571UserTrap1119 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1119."
+ ::= { s571 1119 }
+
+s571UserTrap1120 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1120."
+ ::= { s571 1120 }
+
+s571UserTrap1121 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1121."
+ ::= { s571 1121 }
+
+s571UserTrap1122 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1122."
+ ::= { s571 1122 }
+
+s571UserTrap1123 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1123."
+ ::= { s571 1123 }
+
+s571UserTrap1124 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1124."
+ ::= { s571 1124 }
+
+s571UserTrap1125 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1125."
+ ::= { s571 1125 }
+
+s571UserTrap1126 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1126."
+ ::= { s571 1126 }
+
+s571UserTrap1127 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1127."
+ ::= { s571 1127 }
+
+s571UserTrap1128 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1128."
+ ::= { s571 1128 }
+
+s571UserTrap1129 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1129."
+ ::= { s571 1129 }
+
+s571UserTrap1130 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1130."
+ ::= { s571 1130 }
+
+s571UserTrap1131 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1131."
+ ::= { s571 1131 }
+
+s571UserTrap1132 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1132."
+ ::= { s571 1132 }
+
+s571UserTrap1133 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1133."
+ ::= { s571 1133 }
+
+s571UserTrap1134 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1134."
+ ::= { s571 1134 }
+
+s571UserTrap1135 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1135."
+ ::= { s571 1135 }
+
+s571UserTrap1136 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1136."
+ ::= { s571 1136 }
+
+s571UserTrap1137 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1137."
+ ::= { s571 1137 }
+
+s571UserTrap1138 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1138."
+ ::= { s571 1138 }
+
+s571UserTrap1139 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1139."
+ ::= { s571 1139 }
+
+s571UserTrap1140 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1140."
+ ::= { s571 1140 }
+
+s571UserTrap1141 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1141."
+ ::= { s571 1141 }
+
+s571UserTrap1142 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1142."
+ ::= { s571 1142 }
+
+s571UserTrap1143 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1143."
+ ::= { s571 1143 }
+
+s571UserTrap1144 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1144."
+ ::= { s571 1144 }
+
+s571UserTrap1145 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1145."
+ ::= { s571 1145 }
+
+s571UserTrap1146 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1146."
+ ::= { s571 1146 }
+
+s571UserTrap1147 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1147."
+ ::= { s571 1147 }
+
+s571UserTrap1148 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1148."
+ ::= { s571 1148 }
+
+s571UserTrap1149 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1149."
+ ::= { s571 1149 }
+
+s571UserTrap1150 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1150."
+ ::= { s571 1150 }
+
+s571UserTrap1151 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1151."
+ ::= { s571 1151 }
+
+s571UserTrap1152 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1152."
+ ::= { s571 1152 }
+
+s571UserTrap1153 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1153."
+ ::= { s571 1153 }
+
+s571UserTrap1154 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1154."
+ ::= { s571 1154 }
+
+s571UserTrap1155 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1155."
+ ::= { s571 1155 }
+
+s571UserTrap1156 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1156."
+ ::= { s571 1156 }
+
+s571UserTrap1157 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1157."
+ ::= { s571 1157 }
+
+s571UserTrap1158 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1158."
+ ::= { s571 1158 }
+
+s571UserTrap1159 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1159."
+ ::= { s571 1159 }
+
+s571UserTrap1160 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1160."
+ ::= { s571 1160 }
+
+s571UserTrap1161 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1161."
+ ::= { s571 1161 }
+
+s571UserTrap1162 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1162."
+ ::= { s571 1162 }
+
+s571UserTrap1163 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1163."
+ ::= { s571 1163 }
+
+s571UserTrap1164 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1164."
+ ::= { s571 1164 }
+
+s571UserTrap1165 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1165."
+ ::= { s571 1165 }
+
+s571UserTrap1166 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1166."
+ ::= { s571 1166 }
+
+s571UserTrap1167 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1167."
+ ::= { s571 1167 }
+
+s571UserTrap1168 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1168."
+ ::= { s571 1168 }
+
+s571UserTrap1169 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1169."
+ ::= { s571 1169 }
+
+s571UserTrap1170 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1170."
+ ::= { s571 1170 }
+
+s571UserTrap1171 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1171."
+ ::= { s571 1171 }
+
+s571UserTrap1172 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1172."
+ ::= { s571 1172 }
+
+s571UserTrap1173 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1173."
+ ::= { s571 1173 }
+
+s571UserTrap1174 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1174."
+ ::= { s571 1174 }
+
+s571UserTrap1175 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1175."
+ ::= { s571 1175 }
+
+s571UserTrap1176 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1176."
+ ::= { s571 1176 }
+
+s571UserTrap1177 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1177."
+ ::= { s571 1177 }
+
+s571UserTrap1178 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1178."
+ ::= { s571 1178 }
+
+s571UserTrap1179 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1179."
+ ::= { s571 1179 }
+
+s571UserTrap1180 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1180."
+ ::= { s571 1180 }
+
+s571UserTrap1181 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1181."
+ ::= { s571 1181 }
+
+s571UserTrap1182 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1182."
+ ::= { s571 1182 }
+
+s571UserTrap1183 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1183."
+ ::= { s571 1183 }
+
+s571UserTrap1184 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1184."
+ ::= { s571 1184 }
+
+s571UserTrap1185 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1185."
+ ::= { s571 1185 }
+
+s571UserTrap1186 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1186."
+ ::= { s571 1186 }
+
+s571UserTrap1187 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1187."
+ ::= { s571 1187 }
+
+s571UserTrap1188 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1188."
+ ::= { s571 1188 }
+
+s571UserTrap1189 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1189."
+ ::= { s571 1189 }
+
+s571UserTrap1190 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1190."
+ ::= { s571 1190 }
+
+s571UserTrap1191 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1191."
+ ::= { s571 1191 }
+
+s571UserTrap1192 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1192."
+ ::= { s571 1192 }
+
+s571UserTrap1193 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1193."
+ ::= { s571 1193 }
+
+s571UserTrap1194 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1194."
+ ::= { s571 1194 }
+
+s571UserTrap1195 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1195."
+ ::= { s571 1195 }
+
+s571UserTrap1196 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1196."
+ ::= { s571 1196 }
+
+s571UserTrap1197 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1197."
+ ::= { s571 1197 }
+
+s571UserTrap1198 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1198."
+ ::= { s571 1198 }
+
+s571UserTrap1199 NOTIFICATION-TYPE
+ OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
+ trapEventTypeName, esIndexPoint, esPointName, esID,
+ clock, trapIncludedValue, trapIncludedString,
+ trapEventClassNumber, trapEventClassName }
+ STATUS current
+ DESCRIPTION
+ "This user-defined trap is issued when an event happens that causes a
+ trap with specific trap type 1199."
+ ::= { s571 1199 }
+
+END