+OCCAM-MLT-MIB DEFINITIONS ::= BEGIN
+ IMPORTS
+ occamGenericMonitorModules
+ FROM OCCAM-REG-MODULE
+ TEXTUAL-CONVENTION
+ FROM SNMPv2-TC
+ MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
+ Integer32, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI;
+
+ occamMltMib MODULE-IDENTITY
+ LAST-UPDATED "200104271051Z"
+ ORGANIZATION "Occam Networks"
+ CONTACT-INFO "email support@occamnetworks.com"
+ DESCRIPTION
+ "This mib module describes objects used
+ to perform Metallic Line Testing on customer
+ access lines and to provide results."
+
+ REVISION "200104271051Z"
+ DESCRIPTION "Reformatted certain text"
+
+ REVISION "200704170000Z"
+ DESCRIPTION "replace kOhm with Ohm in DC resistance
+ UNITS"
+
+ REVISION "200702220000Z"
+ DESCRIPTION "remove DISPLAY-HINT"
+
+ REVISION "200609261000Z"
+ DESCRIPTION "Removed Gr909 from fuse test result names"
+
+ REVISION "200602220135Z"
+ DESCRIPTION "Initial version."
+ ::= { occamGenericMonitorModules 3 }
+
+-- TEXTUAL-CONVENTIONS --
+
+ MltTestType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "A selection value for requesting or forcing
+ a test. A requested test will only run if the
+ port is not in use. A forced test will
+ immediately shut the port and run the test."
+ SYNTAX INTEGER { request ( 1 ) ,
+ force ( 2 ) }
+
+ MltTestStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "An indication of test status:
+ none = no test has been requested.
+ mltbusy = another port is currently being tested.
+ complete = the last requested test has completed.
+ portInUse = the last requested port is in use,
+ the test was not run. Rerunning the test as
+ 'forced' will shut the port and run the test.
+ inProgress = the last requested test is still
+ running. mltError = the mlt program reported an
+ error and aborted the test.Check the mltErrorText
+ object.
+ mltNotResponding = the mlt program didn't return
+ a result."
+ SYNTAX INTEGER {
+ none ( 1 ) ,
+ mltBusy ( 2 ),
+ complete ( 3 ) ,
+ portInUse ( 4 ) ,
+ inProgress ( 5 ),
+ mltError ( 6 ),
+ mltNotResponding ( 7 ) }
+
+ MltTestIdentifier ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "An mlt test selection value."
+ SYNTAX INTEGER {
+ statusSuite ( 1 ) ,
+ mltSuite ( 2 ) ,
+ activeModeVoltages ( 3 ) ,
+ highImpedanceModeVoltages ( 4 ) ,
+ dcResistance ( 5 ) ,
+ capacitance ( 6 ) ,
+ loopDetect ( 7 ) ,
+ loopLength ( 8 ) }
+
+ MltTestHookState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "An mlt test hook state value."
+ SYNTAX INTEGER {
+ onhook ( 1 ) ,
+ offhook ( 2 ),
+ notAvailable ( 3 ) }
+
+ MltTestPassFail ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "An mlt test pass/fail value."
+ SYNTAX INTEGER {
+ pass ( 1 ) ,
+ fail ( 2 ),
+ notAvailable ( 3 ) }
+
+ MltTestRingerResult ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "An mlt ringer test result value."
+ SYNTAX INTEGER {
+ pass ( 1 ) ,
+ fail ( 2 ),
+ notAvailable ( 3 ),
+ low ( 4 ) }
+
+ MltTestYesNo ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "An mlt test pass/fail value."
+ SYNTAX INTEGER {
+ yes ( 1 ) ,
+ no ( 2 ),
+ notAvailable ( 3 ) }
+
+-- The Metallic Loop Test Configuration group
+
+ mltTestConfig OBJECT IDENTIFIER
+ ::= { occamMltMib 1 }
+
+
+-- The Metallic Loop Test Status group
+
+ mltTestStatus OBJECT IDENTIFIER
+ ::= { occamMltMib 2 }
+
+
+-- The Metallic Loop Test Results group
+
+ mltTestResults OBJECT IDENTIFIER
+ ::= { occamMltMib 3 }
+
+-- The Metallic Loop Test Notifications group
+
+ mltTestNotifications OBJECT IDENTIFIER
+ ::= { occamMltMib 4 }
+
+
+-- Objects of the MLT Configuration group
+
+ mltTestIdentifier OBJECT-TYPE
+ SYNTAX MltTestIdentifier
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects the mlt test to be run.
+ Setting this value starts a test.
+
+ This is a required parameter.
+
+ Approximate expected test durations are as
+ follows:
+
+ statusSuite 1 second
+ mltSuite 1 minute
+ activeModeVoltages 3 seconds
+ highImpedanceModeVoltages 9 seconds
+ dcResistance 18 seconds
+ capacitance 18 seconds
+ loopDetect 9 seconds
+ loopLength 9 seconds."
+ ::= { mltTestConfig 1 }
+
+ mltTestType OBJECT-TYPE
+ SYNTAX MltTestType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects if a test is requested (only run if port
+ is not in use) or forced.
+ This is an optional parameter. If not specified,
+ the request option is used."
+ ::= { mltTestConfig 2 }
+
+ mltTestPort OBJECT-TYPE
+ SYNTAX Integer32 ( 1 .. 48 )
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects voice channel on which test will be run.
+ This is a required parameter."
+ ::= { mltTestConfig 3 }
+
+ mltDcResistanceRange OBJECT-TYPE
+ SYNTAX Integer32 ( 0 .. 3 )
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects DC Resistance range value.
+ This is an optional paramater. Default is 0
+ (auto mode)."
+ ::= { mltTestConfig 4 }
+
+ mltLoopLengthMultiplier OBJECT-TYPE
+ SYNTAX Integer32 ( 10 .. 200 )
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects loop length multiplier in nf. This is an
+ optional parameter. If not specified an internal
+ default value of 83nF/mile is used."
+ ::= { mltTestConfig 5 }
+
+ mltLoopDetectThreshold OBJECT-TYPE
+ SYNTAX Integer32 ( 5 .. 200 )
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects the detection threshold in nF.
+ This is an optional parameter. If not supplied,
+ a loop detection threshold of 10nF is used."
+ ::= { mltTestConfig 6 }
+
+
+-- Objects of the MLT Test Status group
+
+ mltLastTestStatus OBJECT-TYPE
+ SYNTAX MltTestStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the status of the last run mlt test.
+ Given that the various mlt tests take several
+ seconds to 1 1/2 minutes to run, it is suggested
+ that status polls be spaced 10-20 seconds apart.
+ Additionally, a monitoring application could
+ wait for the testComplete notification."
+ ::= { mltTestStatus 1 }
+
+ mltErrorText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the textual error in the case of an
+ aborted test."
+ ::= { mltTestStatus 2 }
+
+
+-- Objects of the MLT Test Results group
+
+-- mlt status results table
+ mltStatusResultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MltStatusResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides result of the status test
+ suite."
+ ::= { mltTestResults 1 }
+
+ mltStatusResultsEntry OBJECT-TYPE
+ SYNTAX MltStatusResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry holding information about results
+ of status suite tests.
+
+ Note that a numerical result value of -999 means
+ that there was an error of some sort and the
+ value could not be measured."
+ INDEX { mltTestPort }
+ ::= { mltStatusResultsTable 1 }
+
+ MltStatusResultsEntry ::= SEQUENCE {
+ mltStatusAlarm OCTET STRING,
+ mltStatusHookState MltTestHookState,
+ mltStatusTransversalCurrent Integer32,
+ mltStatusLongitudinalCurrent Integer32,
+ mltStatusTipVoltage Integer32,
+ mltStatusRingVoltage Integer32,
+ mltStatusTipRingVoltage Integer32,
+ mltStatusVdd Integer32
+ }
+
+
+ mltStatusAlarm OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates GNK and/or OTEMP alarms active when
+ status test was run."
+ ::= { mltStatusResultsEntry 1 }
+
+
+ mltStatusHookState OBJECT-TYPE
+ SYNTAX MltTestHookState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates line hook state when status test was
+ run."
+ ::= { mltStatusResultsEntry 2 }
+
+
+ mltStatusTransversalCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 mA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates transversal current when status test
+ was run."
+ ::= { mltStatusResultsEntry 3 }
+
+
+ mltStatusLongitudinalCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 mA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates Longitudinal current when status test
+ was run."
+ ::= { mltStatusResultsEntry 4 }
+
+
+ mltStatusTipVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates tip voltage when status test was run."
+ ::= { mltStatusResultsEntry 5 }
+
+
+ mltStatusRingVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates ring voltage when status test was run."
+ ::= { mltStatusResultsEntry 6 }
+
+ mltStatusTipRingVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates tip-ring voltage when status test was
+ run."
+ ::= { mltStatusResultsEntry 7 }
+
+
+ mltStatusVdd OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates Vdd when status test was run."
+ ::= { mltStatusResultsEntry 8 }
+
+-- mlt test results table
+ mltTestResultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MltTestResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides result of the mlt test suite.
+ Note that a numerical result value of -999 means
+ that there was an error of some sort and the
+ value could not be measured.
+ Also, a resistance value of 9999 means that the
+ result was greater than 1000 kOhms, but the exact
+ value could not be measured."
+ ::= { mltTestResults 2 }
+
+ mltTestResultsEntry OBJECT-TYPE
+ SYNTAX MltTestResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry holding information about results
+ of mlt suite tests."
+ INDEX { mltTestPort }
+ ::= { mltTestResultsTable 1 }
+
+ MltTestResultsEntry ::= SEQUENCE {
+ mltTestAlarm OCTET STRING,
+ mltTestHookState MltTestHookState,
+ mltTestVdd Integer32,
+ mltTestActiveModeVoltagesVdctr Integer32,
+ mltTestActiveModeVoltagesVdctg Integer32,
+ mltTestActiveModeVoltagesVdcrg Integer32,
+ mltTestActiveModeVoltagesVactr Integer32,
+ mltTestActiveModeVoltagesVactg Integer32,
+ mltTestActiveModeVoltagesVacrg Integer32,
+ mltTestHighImpedanceModeVoltagesVdctr Integer32,
+ mltTestHighImpedanceModeVoltagesVdctg Integer32,
+ mltTestHighImpedanceModeVoltagesVdcrg Integer32,
+ mltTestHighImpedanceModeVoltagesVactr Integer32,
+ mltTestHighImpedanceModeVoltagesVactg Integer32,
+ mltTestHighImpedanceModeVoltagesVacrg Integer32,
+ mltTestDcCurrentsItransversal Integer32,
+ mltTestDcCurrentsIlongitudinal Integer32,
+ mltTestDcCurrentsItip Integer32,
+ mltTestDcCurrentsIring Integer32,
+ mltTestCapacitanceCeqtr Integer32,
+ mltTestCapacitanceCeqtg Integer32,
+ mltTestCapacitanceCeqrg Integer32,
+ mltTestResistanceRtr Integer32,
+ mltTestResistanceRtg Integer32,
+ mltTestResistanceRrg Integer32,
+ mltTestGr909HazardousPotentialTestResult MltTestPassFail,
+ mltTestGr909ForeignEmfTestResult MltTestPassFail,
+ mltTestGr909FuseTestTipFuse MltTestPassFail,
+ mltTestGr909FuseTestRingFuse MltTestPassFail,
+ mltTestFuseTestTipFuse MltTestPassFail,
+ mltTestFuseTestRingFuse MltTestPassFail,
+ mltTestGr909ResistiveFaultTestResult MltTestPassFail,
+ mltTestGr909ReceiverOffhookTestResult MltTestPassFail,
+ mltTestGr909ReceiverOffhookTestResistance1 Integer32,
+ mltTestGr909ReceiverOffhookTestResistance2 Integer32,
+ mltTestGr909ReceiverOffhookTestDifference Integer32,
+ mltTestGr909RingerTestResult MltTestRingerResult,
+ mltTestGr909RingerTestRen Integer32,
+ mltTestErrors OCTET STRING
+ }
+
+
+ mltTestAlarm OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "GNK and OTEMP bits set by the DuSLIC will be
+ reported as alarms. GNK is typically cause by
+ ground fault or foreign voltage condition.
+ OTEMP is set when the DuSLIC is experiencing
+ thermal overload. This parameter is
+ non-intrusive."
+ ::= { mltTestResultsEntry 1 }
+
+ mltTestHookState OBJECT-TYPE
+ SYNTAX MltTestHookState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hook state reflects the DuSLIC hook bit
+ (offhook/onhook). This parameter is
+ non-intrusive."
+ ::= { mltTestResultsEntry 2 }
+
+ mltTestVdd OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On HDPOTS, internal Voltage VDD will be
+ reported and compared to statistically derived
+ thresholds.
+ This parameter is intrusive during offhook but
+ will be available during onhook."
+ ::= { mltTestResultsEntry 3 }
+
+ mltTestActiveModeVoltagesVdctr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring
+ in a normal no shutdown state. AC voltages for
+ T-R, T-G and R-G will be reported.
+ Active mode measurements will not be available
+ when alarm is detected. This parameter is
+ intrusive and will be available in shutdown
+ state only."
+ ::= { mltTestResultsEntry 4 }
+
+ mltTestActiveModeVoltagesVdctg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring
+ in a normal no shutdown state. AC voltages for
+ T-R, T-G and R-G will be reported.
+ Active mode measurements will not be available
+ when alarm is detected. This parameter is
+ intrusive and will be available in shutdown
+ state only."
+ ::= { mltTestResultsEntry 5 }
+
+ mltTestActiveModeVoltagesVdcrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring
+ in a normal no shutdown state. AC voltages for
+ T-R, T-G and R-G will be reported.
+ Active mode measurements will not be available
+ when alarm is detected. This parameter is
+ intrusive and will be available in shutdown
+ state only."
+ ::= { mltTestResultsEntry 6 }
+
+ mltTestActiveModeVoltagesVactr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring
+ in a normal no shutdown state. Thus, VT and VR
+ measurements should be 0 volt.
+ AC voltages for T-R, T-G and R-G will be
+ reported. Active mode measurements will not be
+ available when alarm is detected. This parameter
+ is intrusive and will be available in shutdown
+ state only."
+ ::= { mltTestResultsEntry 7 }
+
+ mltTestActiveModeVoltagesVactg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring
+ in a normal no shutdown state. Thus, VT and VR
+ measurements should be 0 volt. AC voltages for T-R, T-G
+ and R-G will be reported. Active mode measurements will
+ not be available when alarm is detected. This parameter
+ is intrusive and will be available in shutdown state
+ only."
+ ::= { mltTestResultsEntry 8 }
+
+ mltTestActiveModeVoltagesVacrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring in a
+ normal no shutdown state. Thus, VT and VR measurements
+ should be 0 volt. AC voltages for T-R, T-G and R-G will
+ be reported. Active mode measurements will not be
+ available when alarm is detected. This parameter is
+ intrusive and will be available in shutdown state only."
+
+ ::= { mltTestResultsEntry 9 }
+
+ mltTestHighImpedanceModeVoltagesVdctr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring DC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. DC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltTestResultsEntry 10 }
+
+ mltTestHighImpedanceModeVoltagesVdctg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring DC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. DC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltTestResultsEntry 11 }
+
+ mltTestHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring DC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. DC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltTestResultsEntry 12 }
+
+ mltTestHighImpedanceModeVoltagesVactr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring AC Voltages (Foreign
+ Voltages): In this mode, the DuSLIC tip and ring are in
+ high impedance. The measured voltages represent foreign
+ voltages. AC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltTestResultsEntry 13 }
+
+ mltTestHighImpedanceModeVoltagesVactg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring AC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. AC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltTestResultsEntry 14 }
+
+ mltTestHighImpedanceModeVoltagesVacrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring AC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. AC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltTestResultsEntry 15 }
+
+ mltTestDcCurrentsItransversal OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 mA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Four DC currents will be reported: IT, IL, It and Ir.
+ In normal condition, currents will be measured in
+ active mode. These measurements will not be available if
+ alarm is present."
+ ::= { mltTestResultsEntry 16 }
+
+ mltTestDcCurrentsIlongitudinal OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 mA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Four DC currents will be reported: IT, IL, It and Ir.
+ In normal condition, currents will be measured in active
+ mode. These measurements will not be available if alarm
+ is present."
+ ::= { mltTestResultsEntry 17 }
+
+ mltTestDcCurrentsItip OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 mA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Four DC currents will be reported: IT, IL, It and Ir.
+ In normal condition, currents will be measured in active
+ mode. These measurements will not be available if alarm
+ is present."
+ ::= { mltTestResultsEntry 18 }
+
+ mltTestDcCurrentsIring OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 mA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Four DC currents will be reported: IT, IL, It and Ir.
+ In normal condition, currents will be measured in active
+ mode. These measurements will not be available if alarm
+ is present."
+ ::= { mltTestResultsEntry 19 }
+
+ mltTestCapacitanceCeqtr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacitance measurements will support only single
+ element (2 terminal) circuit. In the presence of a
+ network of capacitance (figure 3), the individual
+ capacitance will not be resolved. The equivalent
+ capacitances CEQtr, CEQtg and CEQrg will be reported.
+ They represent the following:
+
+ CEQtr = Ctr + Ctg/4 + Crg/4
+ CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
+ CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
+
+ Capacitance measurements will not be available if fuse
+ test fails or alarm is present. This test is intrusive
+ and will be available in shutdown state only."
+ ::= { mltTestResultsEntry 20 }
+
+ mltTestCapacitanceCeqtg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacitance measurements will support only single
+ element (2 terminal)
+ circuit. In the presence of a network of capacitance
+ (figure 3), the
+ individual capacitance will not be resolved. The
+ equivalent capacitances CEQtr, CEQtg and CEQrg will be
+ reported. They represent the following:
+
+ CEQtr = Ctr + Ctg/4 + Crg/4
+ CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
+ CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
+
+ Capacitance measurements will not be available if fuse
+ test fails or alarm is present. This test is intrusive
+ and will be available in shutdown state only."
+ ::= { mltTestResultsEntry 21 }
+
+ mltTestCapacitanceCeqrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacitance measurements will support only single
+ element (2 terminal) circuit. In the presence of a
+ network of capacitance (figure 3), the individual
+ capacitance will not be resolved. The equivalent
+ capacitances CEQtr, CEQtg and CEQrg will be reported.
+ They represent the following:
+
+ CEQtr = Ctr + Ctg/4 + Crg/4
+ CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
+ CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
+
+ Capacitance measurements will not be available if fuse
+ test fails or alarm is present. This test is intrusive
+ and will be available in shutdown state only."
+ ::= { mltTestResultsEntry 22 }
+
+ mltTestResistanceRtr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Ohm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "DC resistance measurements will be based on a 3
+ terminal circuit model. Rtr, Rtg and Rrg will be
+ provided. User will have the option of specifying 3
+ resistance ranges: (1) low, (2) medium, (3) high. If not
+ specified, auto mode will be used. Resistance
+ measurements will not be available if fuse test fails or
+ alarm is present. This parameter is intrusive. This test
+ is intrusive and will be available in shutdown state `
+ only."
+ ::= { mltTestResultsEntry 23 }
+
+ mltTestResistanceRtg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Ohm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "DC resistance measurements will be based on a 3
+ terminal circuit model. Rtr, Rtg and Rrg will be
+ provided. User will have the option of specifying
+ 3 resistance ranges: (1) low, (2) medium, (3) high. If
+ not specified, auto mode will be used. Resistance
+ measurements will not be available if fuse test fails or
+ alarm is present. This parameter is intrusive. This test
+ is intrusive and will be available in shutdown state
+ only."
+ ::= { mltTestResultsEntry 24 }
+
+ mltTestResistanceRrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Ohm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "DC resistance measurements will be based on a 3
+ terminal circuit model. Rtr, Rtg and Rrg will be
+ provided. User will have the option of specifying
+ 3 resistance ranges: (1) low, (2) medium, (3) high. If
+ not specified, auto mode will be used. Resistance
+ measurements will not be available if fuse test fails or
+ alarm is present. This parameter is intrusive. This test
+ is intrusive and will be available in shutdown state
+ only."
+ ::= { mltTestResultsEntry 25 }
+
+ mltTestGr909HazardousPotentialTestResult OBJECT-TYPE
+ SYNTAX MltTestPassFail
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails if the T-G or R-G ac voltage is greater
+ than 50 volts rms or the T-G or R-G dc voltage is
+ greater than 135 volts. This test will report pass/fail.
+ This test is intrusive and will be available in shutdown
+ state only."
+ ::= { mltTestResultsEntry 26 }
+
+ mltTestGr909ForeignEmfTestResult OBJECT-TYPE
+ SYNTAX MltTestPassFail
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails if the T-G or R-G ac voltage is greater
+ than 50 volts rms or the T-G or R-G dc voltage is
+ greater than 135 volts. This test will report pass/fail.
+ This test is intrusive and will be available in shutdown
+ state only."
+ ::= { mltTestResultsEntry 27 }
+
+ mltTestGr909FuseTestTipFuse OBJECT-TYPE
+ SYNTAX MltTestPassFail
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "This test determines if these fuses are blown. This
+ test will return pass/fail for tip and ring. This test
+ will not be performed if alarm is present. This
+ parameter is intrusive. This test is intrusive and will
+ be available in shutdown state only.
+
+ This object is obsolete. Object name was changed."
+ ::= { mltTestResultsEntry 28 }
+
+ mltTestGr909FuseTestRingFuse OBJECT-TYPE
+ SYNTAX MltTestPassFail
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "This test determines if these fuses are blown. This
+ test will return pass/fail for tip and ring. This test
+ will not be performed if alarm is present. This
+ parameter is intrusive. This test is intrusive and will
+ be available in shutdown state only.
+
+ This object is obsolete. Object name was changed."
+ ::= { mltTestResultsEntry 29 }
+
+ mltTestFuseTestTipFuse OBJECT-TYPE
+ SYNTAX MltTestPassFail
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test determines if these fuses are blown. This
+ test will return pass/fail for tip and ring. This test
+ will not be performed if alarm is present. This
+ parameter is intrusive. This test is intrusive and will
+ be available in shutdown state only."
+ ::= { mltTestResultsEntry 38 }
+
+ mltTestFuseTestRingFuse OBJECT-TYPE
+ SYNTAX MltTestPassFail
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test determines if these fuses are blown. This
+ test will return pass/fail for tip and ring. This test
+ will not be performed if alarm is present. This
+ parameter is intrusive. This test is intrusive and will
+ be available in shutdown state only."
+ ::= { mltTestResultsEntry 39 }
+
+ mltTestGr909ResistiveFaultTestResult OBJECT-TYPE
+ SYNTAX MltTestPassFail
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails if the T-R, T-G or R-G dc resistance is
+ less than 150k ohm. This test will not be performed if
+ fuse test fails or alarm is present. This test will
+ return pass/fail. This test is intrusive and will be
+ available in shutdown state only."
+ ::= { mltTestResultsEntry 30 }
+
+ mltTestGr909ReceiverOffhookTestResult OBJECT-TYPE
+ SYNTAX MltTestPassFail
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails if a non-linearity in the T-R dc
+ resistance of greater than 15% when measured at two
+ different voltage levels exists. This test will not be
+ performed if fuse test fails or alarm is present. This
+ test will return the DC resistances at two different
+ operating points and the percent difference between the
+ two DC resistances. This test is intrusive and will be
+ available in shutdown state only. "
+ ::= { mltTestResultsEntry 31 }
+
+ mltTestGr909ReceiverOffhookTestResistance1 OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Ohm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails if a non-linearity in the T-R dc
+ resistance of greater than 15% when measured at two
+ different voltage levels exists. This test will not be
+ performed if fuse test fails or alarm is present. This
+ test will return the DC resistances at two different
+ operating points and the percent difference between the
+ two DC resistances. This test is intrusive and will be
+ available in shutdown state only. "
+ ::= { mltTestResultsEntry 32 }
+
+ mltTestGr909ReceiverOffhookTestResistance2 OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Ohm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails if a non-linearity in the T-R dc
+ resistance of greater than 15% when measured at two
+ different voltage levels exists. This test will not be
+ performed if fuse test fails or alarm is present. This
+ test will return the DC resistances at two different
+ operating points and the percent difference between the
+ two DC resistances. This test is intrusive and will be
+ available in shutdown state only. "
+ ::= { mltTestResultsEntry 33 }
+
+ mltTestGr909ReceiverOffhookTestDifference OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails if a non-linearity in the T-R dc
+ resistance of greater than 15% when measured at two
+ different voltage levels exists. This test will not be
+ performed if fuse test fails or alarm is present. This
+ test will return the DC resistances at two different
+ operating points and the percent difference between the
+ two DC resistances. This test is intrusive and will be
+ available in shutdown state only. "
+ ::= { mltTestResultsEntry 34 }
+
+ mltTestGr909RingerTestResult OBJECT-TYPE
+ SYNTAX MltTestRingerResult
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails when the equivalent ringer count across
+ tip and ring is less than 0.175 REN or greater than 5
+ REN. This test will not run if fuse test fails or alarm
+ is present. This test will report passed/fail and the
+ REN number. This parameter is intrusive and will be
+ available in shutdown state shutdown only."
+ ::= { mltTestResultsEntry 35 }
+
+ mltTestGr909RingerTestRen OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 REN"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This test fails when the equivalent ringer count across
+ tip and ring is less than 0.175 REN or greater than 5
+ REN. This test will not run if fuse test fails or alarm
+ is present. This test will report passed/fail and the
+ REN number. This parameter is intrusive and will be
+ available in shutdown state shutdown only."
+ ::= { mltTestResultsEntry 36 }
+
+ mltTestErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates GNK and/or OTEMP alarms active when test was
+ run."
+ ::= { mltTestResultsEntry 37 }
+
+-- mlt active mode voltages results table
+ mltActiveModeVoltagesResultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MltActiveModeVoltagesResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides results of the mlt active mode
+ voltages test.
+ Note that a numerical result value of -999 means that
+ there was an error of some sort and the value could not
+ be measured."
+ ::= { mltTestResults 3 }
+
+ mltActiveModeVoltagesResultsEntry OBJECT-TYPE
+ SYNTAX MltActiveModeVoltagesResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry holding information about results
+ of mlt active mode voltages test."
+ INDEX { mltTestPort }
+ ::= { mltActiveModeVoltagesResultsTable 1 }
+
+ MltActiveModeVoltagesResultsEntry ::= SEQUENCE {
+ mltActiveModeVoltagesVdctr Integer32,
+ mltActiveModeVoltagesVdctg Integer32,
+ mltActiveModeVoltagesVdcrg Integer32,
+ mltActiveModeVoltagesVactr Integer32,
+ mltActiveModeVoltagesVactg Integer32,
+ mltActiveModeVoltagesVacrg Integer32,
+ mltActiveModeVoltagesErrors OCTET STRING
+ }
+
+ mltActiveModeVoltagesVdctr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring in a
+ normal no shutdown state. AC voltages for T-R, T-G and
+ R-G will be reported.
+ Active mode measurements will not be available when
+ alarm is detected. This parameter is intrusive and will
+ be available in shutdown state only."
+ ::= { mltActiveModeVoltagesResultsEntry 1 }
+
+ mltActiveModeVoltagesVdctg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring in a
+ normal no shutdown state. AC voltages for T-R, T-G and
+ R-G will be reported. Active mode measurements will not
+ be available when alarm is detected. This parameter is
+ intrusive and will be available in shutdown state only."
+ ::= { mltActiveModeVoltagesResultsEntry 2 }
+
+ mltActiveModeVoltagesVdcrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring in a
+ normal no shutdown state. AC voltages for T-R, T-G and
+ R-G will be reported. Active mode measurements will not
+ be available when alarm is detected. This parameter is
+ intrusive and will be available in shutdown state only."
+ ::= { mltActiveModeVoltagesResultsEntry 3 }
+
+ mltActiveModeVoltagesVactr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring in a
+ normal no shutdown state. Thus, VT and VR measurements
+ should be 0 volt. AC voltages for T-R, T-G and R-G will
+ be reported. Active mode measurements will not be
+ available when alarm is detected. This parameter is
+ intrusive and will be available in shutdown state only."
+ ::= { mltActiveModeVoltagesResultsEntry 4 }
+
+ mltActiveModeVoltagesVactg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring in a
+ normal no shutdown state. Thus, VT and VR measurements
+ should be 0 volt. AC voltages for T-R, T-G and R-G will
+ be reported. Active mode measurements will not be
+ available when alarm is detected. This parameter is
+ intrusive and will be available in shutdown state only."
+ ::= { mltActiveModeVoltagesResultsEntry 5 }
+
+ mltActiveModeVoltagesVacrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active Mode Tip/Ring AC Voltages:
+ In active mode, the DuSLIC drives the tip/ring in a
+ normal no shutdown state. Thus, VT and VR measurements
+ should be 0 volt. AC voltages for T-R, T-G and R-G will
+ be reported.
+ Active mode measurements will not be available when
+ alarm is detected. This parameter is intrusive and will
+ be available in shutdown state only."
+
+ ::= { mltActiveModeVoltagesResultsEntry 6 }
+
+ mltActiveModeVoltagesErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates GNK and/or OTEMP alarms active when test was
+ run."
+ ::= { mltActiveModeVoltagesResultsEntry 7 }
+
+-- mlt high impedance mode voltages results table
+ mltHighImpedanceModeVoltagesResultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF
+MltHighImpedanceModeVoltagesResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides result of the mlt test suite.
+ Note that a numerical result value of -999 means that
+ there was an error of some sort and the value could not
+ be measured."
+ ::= { mltTestResults 4 }
+
+ mltHighImpedanceModeVoltagesResultsEntry OBJECT-TYPE
+ SYNTAX MltHighImpedanceModeVoltagesResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry holding information about results
+ of mlt high impedance mode voltages test."
+ INDEX { mltTestPort }
+ ::= { mltHighImpedanceModeVoltagesResultsTable 1 }
+
+ MltHighImpedanceModeVoltagesResultsEntry ::= SEQUENCE {
+ mltHighImpedanceModeVoltagesVdctr Integer32,
+ mltHighImpedanceModeVoltagesVdctg Integer32,
+ mltHighImpedanceModeVoltagesVdcrg Integer32,
+ mltHighImpedanceModeVoltagesVactr Integer32,
+ mltHighImpedanceModeVoltagesVactg Integer32,
+ mltHighImpedanceModeVoltagesVacrg Integer32,
+ mltHighImpedanceModeVoltagesErrors OCTET STRING
+ }
+
+ mltHighImpedanceModeVoltagesVdctr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring DC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. DC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltHighImpedanceModeVoltagesResultsEntry 1 }
+
+ mltHighImpedanceModeVoltagesVdctg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring DC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. DC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltHighImpedanceModeVoltagesResultsEntry 2 }
+
+ mltHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vdc"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring DC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. DC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltHighImpedanceModeVoltagesResultsEntry 3 }
+
+ mltHighImpedanceModeVoltagesVactr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring AC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. AC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltHighImpedanceModeVoltagesResultsEntry 4 }
+
+ mltHighImpedanceModeVoltagesVactg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring AC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. AC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltHighImpedanceModeVoltagesResultsEntry 5 }
+
+ mltHighImpedanceModeVoltagesVacrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Vrms"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "High Impedance Mode Tip/Ring AC Voltages (Foreign
+ Voltages):
+ In this mode, the DuSLIC tip and ring are in high
+ impedance. The measured voltages represent foreign
+ voltages. AC voltages for T-R, T-G and R-G will be
+ reported. This parameter is intrusive and will be
+ available in shutdown state only."
+ ::= { mltHighImpedanceModeVoltagesResultsEntry 6 }
+
+ mltHighImpedanceModeVoltagesErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates GNK and/or OTEMP alarms active when test was
+ run."
+ ::= { mltHighImpedanceModeVoltagesResultsEntry 7 }
+
+-- mlt DC resistance results table
+ mltDcResistanceResultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MltDcResistanceResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides result of the DC resistance test.
+ Note that a numerical result value of -999 means that
+ there was an error of some sort and the value could not
+ be measured. Also, a resistance value of 9999 means
+ that the result was greater than 1000 kOhms, but the
+ exact value could not be measured."
+ ::= { mltTestResults 5 }
+
+ mltDcResistanceResultsEntry OBJECT-TYPE
+ SYNTAX MltDcResistanceResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry holding information about results
+ of mlt DC resistance test."
+ INDEX { mltTestPort }
+ ::= { mltDcResistanceResultsTable 1 }
+
+ MltDcResistanceResultsEntry ::= SEQUENCE {
+ mltDcResistanceRtr Integer32,
+ mltDcResistanceRtg Integer32,
+ mltDcResistanceRrg Integer32,
+ mltDcResistanceErrors OCTET STRING
+ }
+
+
+ mltDcResistanceRtr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Ohm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "DC resistance measurements will be based on a 3
+ terminal circuit model. Rtr, Rtg and Rrg will be
+ provided. User will have the option of specifying
+ 3 resistance ranges: (1) low, (2) medium, (3) high. If
+ not specified, auto mode will be used. Resistance
+ measurements will not be available if fuse test fails or
+ alarm is present. This parameter is intrusive. This test
+ is intrusive and will be available in shutdown state
+ only."
+ ::= { mltDcResistanceResultsEntry 1 }
+
+ mltDcResistanceRtg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Ohm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "DC resistance measurements will be based on a 3
+ terminal circuit model. Rtr, Rtg and Rrg will be
+ provided. User will have the option of specifying
+ 3 resistance ranges: (1) low, (2) medium, (3) high. If
+ not specified, auto mode will be used. Resistance
+ measurements will not be available if fuse test fails or
+ alarm is present. This parameter is intrusive. This test
+ is intrusive and will be available in shutdown state
+ only."
+ ::= { mltDcResistanceResultsEntry 2 }
+
+ mltDcResistanceRrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Ohm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "DC resistance measurements will be based on a 3
+ terminal circuit model. Rtr, Rtg and Rrg will be
+ provided. User will have the option of specifying
+ 3 resistance ranges: (1) low, (2) medium, (3) high. If
+ not specified, auto mode will be used. Resistance
+ measurements will not be available if fuse test fails or
+ alarm is present. This parameter is intrusive. This test
+ is intrusive and will be available in shutdown state
+ only."
+ ::= { mltDcResistanceResultsEntry 3 }
+
+ mltDcResistanceErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates GNK and/or OTEMP alarms active when test was
+ run."
+ ::= { mltDcResistanceResultsEntry 4 }
+
+-- mlt capacitance results table
+ mltCapacitanceResultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MltCapacitanceResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides result of the mlt test suite.
+ Note that a numerical result value of -999 means that
+ there was an error of some sort and the value could not
+ be measured."
+ ::= { mltTestResults 6 }
+
+ mltCapacitanceResultsEntry OBJECT-TYPE
+ SYNTAX MltCapacitanceResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry holding information about results
+ of mlt capacitance test."
+ INDEX { mltTestPort }
+ ::= { mltCapacitanceResultsTable 1 }
+
+ MltCapacitanceResultsEntry ::= SEQUENCE {
+ mltCapacitanceCeqtr Integer32,
+ mltCapacitanceCeqtg Integer32,
+ mltCapacitanceCeqrg Integer32,
+ mltCapacitanceErrors OCTET STRING
+ }
+
+ mltCapacitanceCeqtr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacitance measurements will support only single
+ element (2 terminal) circuit. In the presence of a
+ network of capacitance (figure 3), the individual
+ capacitance will not be resolved. The equivalent
+ capacitances CEQtr, CEQtg and CEQrg will be reported.
+ They represent the following:
+
+ CEQtr = Ctr + Ctg/4 + Crg/4
+ CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
+ CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
+
+ Capacitance measurements will not be available if fuse
+ test fails or alarm is present. This test is intrusive
+ and will be available in shutdown state only."
+ ::= { mltCapacitanceResultsEntry 1 }
+
+ mltCapacitanceCeqtg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacitance measurements will support only single
+ element (2 terminal) circuit. In the presence of a
+ network of capacitance (figure 3), the individual
+ capacitance will not be resolved. The equivalent
+ capacitances CEQtr, CEQtg and CEQrg will be reported.
+ They represent the following:
+
+ CEQtr = Ctr + Ctg/4 + Crg/4
+ CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
+ CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
+
+ Capacitance measurements will not be available if fuse
+ test fails or alarm is present. This test is intrusive
+ and will be available in shutdown state only."
+ ::= { mltCapacitanceResultsEntry 2 }
+
+ mltCapacitanceCeqrg OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Capacitance measurements will support only single
+ element (2 terminal) circuit. In the presence of a
+ network of capacitance (figure 3), the individual
+ capacitance will not be resolved. The equivalent
+ capacitances CEQtr, CEQtg and CEQrg will be reported.
+ They represent the following:
+
+ CEQtr = Ctr + Ctg/4 + Crg/4
+ CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
+ CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
+
+ Capacitance measurements will not be available if fuse
+ test fails or alarm is present. This test is intrusive
+ and will be available in shutdown state only."
+ ::= { mltCapacitanceResultsEntry 3 }
+
+ mltCapacitanceErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates GNK and/or OTEMP alarms active when test was
+ run."
+ ::= { mltCapacitanceResultsEntry 4 }
+
+-- mlt loop detect results table
+ mltLoopDetectResultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MltLoopDetectResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides result of the mlt loop detect test.
+ Note that a numerical result value of -999 means that
+ there was an error of some sort and the value could not
+ be measured."
+ ::= { mltTestResults 7 }
+
+ mltLoopDetectResultsEntry OBJECT-TYPE
+ SYNTAX MltLoopDetectResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry holding information about results
+ of mlt loop detect test."
+ INDEX { mltTestPort }
+ ::= { mltLoopDetectResultsTable 1 }
+
+ MltLoopDetectResultsEntry ::= SEQUENCE {
+ mltLoopDetectLoopCapacitance Integer32,
+ mltLoopDetectDetectionThreshold Integer32,
+ mltLoopDetectLoopDetected MltTestYesNo,
+ mltLoopDetectErrors OCTET STRING
+ }
+
+ mltLoopDetectLoopCapacitance OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Loop detection will be based on tip-ring capacitance
+ measurement. User will be able to specify the detection
+ threshold. If not supplied,loop detection threshold of
+ 10 nF will be used. This test will not be available if
+ fuse test fails or alarm is present. This test is
+ intrusive and will be available in shutdown state only."
+ ::= { mltLoopDetectResultsEntry 1 }
+
+ mltLoopDetectDetectionThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Loop detection will be based on tip-ring capacitance
+ measurement. User will be able to specify the detection
+ threshold. If not supplied, loop detection threshold of
+ 10 nF will be used. This test will not be available if
+ fuse test fails or alarm is present. This test is
+ intrusive and will be available in shutdown state only."
+ ::= { mltLoopDetectResultsEntry 2 }
+
+ mltLoopDetectLoopDetected OBJECT-TYPE
+ SYNTAX MltTestYesNo
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Loop detection will be based on tip-ring capacitance
+ measurement. User will be able to specify the detection
+ threshold. If not supplied, loop detection threshold
+ of 10 nF will be used. This test will not be available
+ if fuse test fails or alarm is present. This test is
+ intrusive and will be available in shutdown state only."
+ ::= { mltLoopDetectResultsEntry 3 }
+
+ mltLoopDetectErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates GNK and/or OTEMP alarms active when test
+ was run."
+ ::= { mltLoopDetectResultsEntry 4 }
+
+-- mlt loop length results table
+ mltLoopLengthResultsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MltLoopLengthResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides result of the mlt loop length test.
+ Note that a numerical result value of -999 means that
+ there was an error of some sort and the value could
+ not be measured."
+ ::= { mltTestResults 8 }
+
+ mltLoopLengthResultsEntry OBJECT-TYPE
+ SYNTAX MltLoopLengthResultsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry holding information about results
+ of mlt loop length test."
+ INDEX { mltTestPort }
+ ::= { mltLoopLengthResultsTable 1 }
+
+ MltLoopLengthResultsEntry ::= SEQUENCE {
+ mltLoopLengthCapacitanceFactor Integer32,
+ mltLoopLengthLoopCapacitance Integer32,
+ mltLoopLengthLoopLength Integer32,
+ mltLoopLengthUncompensatedLoopCapacitance Integer32,
+ mltLoopLengthUncompensatedLoopLength Integer32,
+ mltLoopLengthErrors OCTET STRING
+ }
+
+ mltLoopLengthCapacitanceFactor OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF/mile"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Loop length estimate will be based on tip-ring
+ capacitance measurement. User will be able to
+ specify the loop length multiplier. If not supplied,
+ loop length multiplier of 83 nF/ mile will be used.
+ This test will not be available if fuse test fails
+ or alarm is present. This test is intrusive and will
+ be available in shutdown state only."
+ ::= { mltLoopLengthResultsEntry 1 }
+
+ mltLoopLengthLoopCapacitance OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Loop length estimate will be based on tip-ring
+ capacitance measurement. User will be able to specify
+ the loop length multiplier. If not supplied, loop length
+ multiplier of 83 nF/ mile will be used. This test will
+ not be available if fuse test fails or alarm is present.
+ This test is intrusive and will be available in shutdown
+ state only. "
+ ::= { mltLoopLengthResultsEntry 2 }
+
+ mltLoopLengthLoopLength OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "ft"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Loop length estimate will be based on tip-ring
+ capacitance measurement. User will be able to specify
+ the loop length multiplier. If not supplied, loop length
+ multiplier of 83 nF/ mile will be used. This test will
+ not be available if fuse test fails or alarm is present.
+ This test is intrusive and will be available in shutdown
+ state only. "
+ ::= { mltLoopLengthResultsEntry 3 }
+
+ mltLoopLengthUncompensatedLoopCapacitance OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "nF"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Loop length estimate will be based on tip-ring
+ capacitance measurement. User will be able to specify
+ the loop length multiplier. If not supplied, loop length
+ multiplier of 83 nF/ mile will be used. This test will
+ not be available if fuse test fails or alarm is present.
+ This test is intrusive and will be available in shutdown
+ state only. This value has no DSL correction."
+ ::= { mltLoopLengthResultsEntry 4 }
+
+ mltLoopLengthUncompensatedLoopLength OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "ft"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Loop length estimate will be based on tip-ring
+ capacitance measurement. User will be able to specify
+ the loop length multiplier. If not supplied, loop length
+ multiplier of 83 nF/ mile will be used. This test will
+ not be available if fuse test fails or alarm is present.
+ This test is intrusive and will be available in shutdown
+ state only. This value has no DSL correction."
+ ::= { mltLoopLengthResultsEntry 5 }
+
+
+ mltLoopLengthErrors OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates GNK and/or OTEMP alarms active when test was
+ run."
+ ::= { mltLoopLengthResultsEntry 6 }
+
+-- notifications
+
+ mltTestCompletedNotification NOTIFICATION-TYPE
+ OBJECTS { mltTestIdentifier, mltTestPort,
+ mltLastTestStatus, mltErrorText }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent to the
+ requesting host when the requested mlt
+ test has completed."
+ ::= { mltTestNotifications 1 }
+
+
+
+END
|