diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/cisco/CERENT-454-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/cisco/CERENT-454-MIB')
| -rw-r--r-- | MIBS/cisco/CERENT-454-MIB | 24419 |
1 files changed, 24419 insertions, 0 deletions
diff --git a/MIBS/cisco/CERENT-454-MIB b/MIBS/cisco/CERENT-454-MIB new file mode 100644 index 0000000..9ac0b5f --- /dev/null +++ b/MIBS/cisco/CERENT-454-MIB @@ -0,0 +1,24419 @@ +-- ************************************************************** +-- Cerent-454-MIB module +-- +-- This module contains the objects and events for the +-- Cisco ONS 15454 + +-- Copyright (c) 1998-1999 by Cerent Corporation, Inc. +-- Copyright (c) 2000-2002, 2004-2005 by Cisco Systems, Inc. +-- All rights reserved. +-- +-- ************************************************************** + +CERENT-454-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-TYPE, + OBJECT-IDENTITY, + NOTIFICATION-TYPE, + Integer32, + Unsigned32, + Counter32 + FROM SNMPv2-SMI + TEXTUAL-CONVENTION, + DisplayString, + TruthValue, + TimeStamp + FROM SNMPv2-TC + MODULE-COMPLIANCE, + OBJECT-GROUP, + NOTIFICATION-GROUP + FROM SNMPv2-CONF + cerentProducts, + cerentModules + FROM CERENT-GLOBAL-REGISTRY + CerentNotificationClass, + CerentAlarmSeverity, + CerentAlarmStatus, + CerentAlarmServiceAffecting, + CerentMonitorType, + CerentLocation, + CerentPeriod, + CerentPortNumber + FROM CERENT-TC; + +cerent454MibModule MODULE-IDENTITY + LAST-UPDATED "0410010000Z" -- 2004/Oct/01 + ORGANIZATION "Cisco Systems, Inc." + CONTACT-INFO + " support@Cisco.com + + Postal: Cisco Systems + 1450 N. McDowell Blvd. + Petaluma, CA 94954 + USA + + Tel: +1-877-323-7368" + DESCRIPTION + "This module provides the definitions for + objects for managing Cisco OTBU ONS 15454." + + REVISION "0410010000Z" -- 2004/Oct/01 + DESCRIPTION + "This file can be used with R5.0 release." + + ::= { cerentModules 20 } + +cerent454Mib OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The is the node under which all Cisco ONS 15454 + specific mib object are located." + ::= { cerentProducts 10 } + +cerent454Conformance OBJECT-IDENTITY + STATUS current + DESCRIPTION + "This node is created compliance. Has + objects as required by the RFCs" + ::= { cerent454Mib 10 } + +-- ******************************************************** + +cerentCommonObjects OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The objects here are expected to be + used by all Cisco OTBU Products. + These will be mixed with specific + objects of the product-specific branch." + ::= { cerent454Mib 100 } +-- +cerentCommonEvents OBJECT-IDENTITY + STATUS current + DESCRIPTION + "This branch is similar to cerentCommonObjects, + except that this will have only events" + ::= { cerent454Mib 200 } + +-- ******************************************************** + +cerent454Groups OBJECT-IDENTITY + STATUS current + DESCRIPTION + "" + ::= { cerent454Conformance 10 } + +cerent454Compliance OBJECT-IDENTITY + STATUS current + DESCRIPTION + "" + ::= { cerent454Conformance 20 } + +-- ************************************************************** +-- Cisco ONS 15454 specific textual conventions +-- ************************************************************** + +Cerent454AlarmType ::= TEXTUAL-CONVENTION + -- DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "This TC is used by the NMS to map the alarm type + received by the trap and and display the string + shown in LHS." + SYNTAX INTEGER { + alarmUnknown ( 1 ), + alarmCutoffIsInManualMode ( 10 ), + failureDetectedExternalToTheNE ( 20 ), + externalError ( 30 ), + excessiveSwitching ( 40 ), + sdccTerminationFailure ( 50 ), + incomingFailureCondition ( 60 ), + alarmIndicationSignal ( 70 ), + alarmIndicationSignalLine ( 80 ), + alarmIndicationSignalPath ( 90 ), + alarmIndicationSignalVT ( 100 ), + apsChannelFailure ( 110 ), + channelByteFailureAPS ( 120 ), + channelProtectionSwitchingChannelMatchFailureAPS ( 130 ), + channelAutomaticProtectionSwitchModeMismatchAPS ( 140 ), + farEndProtectionLineFailure ( 150 ), + inconsistentAPSCode ( 160 ), + improperAPSCode ( 170 ), + nodeIdMismatch ( 180 ), + channelDefaultKAPS ( 190 ), + connectionLoss ( 200 ), + + bipolarViolation ( 210 ), + carrierLossOnTheLAN ( 220 ), + concatenationErrorSTS ( 230 ), + excessCollisionsOnTheLAN ( 240 ), + facilityFailure ( 250 ), + farEndAIS ( 260 ), + farEndMultipleDS1LOSDetectedOnDS3 ( 270 ), + farEndDS1EqptFailNonServiceAffecting ( 280 ), + farEndDS1EqptFailServiceAffecting ( 290 ), + farEndSingleDS1LOS ( 300 ), + farEndDS3EqptFailNonServiceAffecting ( 310 ), + farEndDS3EqptFailServiceAffecting ( 320 ), + farEndCommonEquipmentFailureNonServiceAffecting ( 330 ), + farEndIDLE ( 340 ), + farEndLOS ( 350 ), + farEndLOF ( 360 ), + farEndBlockError ( 370 ), + ds3IdleCondition ( 380 ), + lossOfFrame ( 390 ), + lossOfPointer ( 400 ), + + lossOfPointerPath ( 410 ), + lossOfPointerVT ( 420 ), + lossOfSignal ( 430 ), + outOfFrame ( 440 ), + pathSelectorFailure ( 450 ), + remoteAlarmIndication ( 460 ), + remoteFailureIndication ( 470 ), + remoteFailureIndicationLine ( 480 ), + remoteFailureIndicationPath ( 490 ), + remoteFailureIndicationVT ( 500 ), + + signalDegrade ( 510 ), + severelyErroredFrame ( 520 ), + signalFailure ( 530 ), + signalLabelMismatchFailure ( 540 ), + payloadDefectIndication ( 550 ), + + payloadDefectIndicationPath ( 560 ), + payloadLabelMismatchPath ( 570 ), + signalLabelMismatchFailurePayloadLabelMismatchVT ( 580 ), + unequippedPath ( 590 ), + signalLabelMismatchFailureUnequippedVT ( 600 ), + lossOfSynchronization ( 610 ), + outOfSynchronization ( 620 ), + primarySynchronizationReferenceFailure ( 630 ), + secondarySynchronizationReferenceFailure ( 640 ), + thirdSynchronizationReferenceFailure ( 650 ), + fourthSynchronizationReferenceFailure ( 660 ), + fifthSynchronizationReferenceFailure ( 670 ), + sixthSynchronizationReferenceFailure ( 680 ), + + failedToReceiveSynchronizationStatusMessage ( 690 ), + synchronizationStatusMessagesAreDisabledOnThisInterface ( 700 ), + stratum1PrimaryReferenceSourceTraceable ( 710 ), + synchronizedTraceabilityUnknown ( 720 ), + stratum2Traceable ( 730 ), + transitNodeClockTraceable ( 740 ), + + stratum3ETraceable ( 750 ), + stratum3Traceable ( 760 ), + sonetMinimumClockTraceable ( 770 ), + stratum4Traceable ( 780 ), + doNotUseForSynchronization ( 790 ), + reservedForNetworkSynchronizationUse ( 800 ), + + outgoingFailureCondition ( 810 ), + remoteDefectIndicationLine ( 820 ), + remoteDefectIndicationPath ( 830 ), + freeRunningSynchronizationMode ( 840 ), + holdoverSynchronizationMode ( 850 ), + fastStartSynchronizationMode ( 860 ), + internalFault ( 870 ), + internalError ( 880 ), + internalMessageError ( 890 ), + mismatchOfEquipmentAndAttributes ( 900 ), + watchdogTimerTimeout ( 910 ), + softwareFaultOrFailure ( 920 ), + softwareFaultDataIntegrityFault ( 930 ), + programFailure ( 940 ), + + controlEquipmentFailure ( 950 ), + primaryNonVolatileBackupMemoryFailure ( 960 ), + secondaryNonVolatileBackupMemoryFailure ( 970 ), + controlBusFailure ( 980 ), + controlBus1Failure ( 990 ), + controlBus2Failure ( 1000 ), + + tccAToShelfSlot1DROP1CommunicationFailure ( 1010 ), + tccAToShelfSlot2DROP2CommunicationFailure ( 1020 ), + tccAToShelfSlot3DROP3CommunicationFailure ( 1030 ), + tccAToShelfSlot4DROP4CommunicationFailure ( 1040 ), + tccAToShelfSlot5TRUNK1CommunicationFailure ( 1050 ), + tccAToShelfSlot6TRUNK2CommunicationFailure ( 1060 ), + tccAToShelfSlot7TCCACommunicationFailure ( 1070 ), + tccAToShelfSlot8XCONACommunicationFailure ( 1080 ), + tccAToShelfSlot9AICCommunicationFailure ( 1090 ), + tccAToShelfSlot10XCONBCommunicationFailure ( 1100 ), + tccAToShelfSlot11TCCBCommunicationFailure ( 1110 ), + tccAToShelfSlot12TRUNK3CommunicationFailure ( 1120 ), + tccAToShelfSlot13TRUNK4CommunicationFailure ( 1130 ), + tccAToShelfSlot14DROP5CommunicationFailure ( 1140 ), + tccAToShelfSlot15DROP6CommunicationFailure ( 1150 ), + tccAToShelfSlot16DROP7CommunicationFailure ( 1160 ), + tccAToShelfSlot17DROP8CommunicationFailure ( 1170 ), + tccAToDCCAProcessorCommunicationFailure ( 1180 ), + tccBToShelfSlot1DROP1CommunicationFailure ( 1190 ), + tccBToShelfSlot2DROP2CommunicationFailure ( 1200 ), + tccBToShelfSlot3DROP3CommunicationFailure ( 1210 ), + tccBToShelfSlot4DROP4CommunicationFailure ( 1220 ), + tccBToShelfSlot5TRUNK1CommunicationFailure ( 1230 ), + tccBToShelfSlot6TRUNK2CommunicationFailure ( 1240 ), + tccBToShelfSlot7TCCACommunicationFailure ( 1250 ), + tccBToShelfSlot8XCONACommunicationFailure ( 1260 ), + tccBToShelfSlot9AICCommunicationFailure ( 1270 ), + tccBToShelfSlot10XCONBCommunicationFailure ( 1280 ), + tccBToShelfSlot11TCCBCommunicationFailure ( 1290 ), + tccBToShelfSlot12TRUNK3CommunicationFailure ( 1300 ), + tccBToShelfSlot13TRUNK4CommunicationFailure ( 1310 ), + tccBToShelfSlot14DROP5CommunicationFailure ( 1320 ), + tccBToShelfSlot15DROP6CommunicationFailure ( 1330 ), + tccBToShelfSlot16DROP7CommunicationFailure ( 1340 ), + tccBToShelfSlot17DROP8CommunicationFailure ( 1350 ), + tccBToDCCBProcessorCommunicationFailure ( 1360 ), + + controlEquipmentControlCommunicationsEquipmentFailure ( 1370 ), + controlProcessorFailure ( 1380 ), + workingMemoryFailure ( 1390 ), + + interconnectionEquipmentFailure ( 1400 ), + payloadBusFailureToIOSlot1XCONSlot8 ( 1410 ), + payloadBusFailureToIOSlot2XCONSlot8 ( 1420 ), + payloadBusFailureToIOSlot3XCONSlot8 ( 1430 ), + payloadBusFailureToIOSlot4XCONSlot8 ( 1440 ), + payloadBusFailureToIOSlot5XCONSlot8 ( 1450 ), + payloadBusFailureToIOSlot6XCONSlot8 ( 1460 ), + payloadBusFailureToIOSlot12XCONSlot8 ( 1470 ), + payloadBusFailureToIOSlot13XCONSlot8 ( 1480 ), + payloadBusFailureToIOSlot14XCONSlot8 ( 1490 ), + payloadBusFailureToIOSlot15XCONSlot8 ( 1500 ), + payloadBusFailureToIOSlot16XCONSlot8 ( 1510 ), + payloadBusFailureToIOSlot17XCONSlot8 ( 1520 ), + payloadBusFailureToIOSlot1XCONSlot10 ( 1530 ), + payloadBusFailureToIOSlot2XCONSlot10 ( 1540 ), + payloadBusFailureToIOSlot3XCONSlot10 ( 1550 ), + payloadBusFailureToIOSlot4XCONSlot10 ( 1560 ), + payloadBusFailureToIOSlot5XCONSlot10 ( 1570 ), + payloadBusFailureToIOSlot6XCONSlot10 ( 1580 ), + payloadBusFailureToIOSlot12XCONSlot10 ( 1590 ), + payloadBusFailureToIOSlot13XCONSlot10 ( 1600 ), + payloadBusFailureToIOSlot14XCONSlot10 ( 1610 ), + payloadBusFailureToIOSlot15XCONSlot10 ( 1620 ), + payloadBusFailureToIOSlot16XCONSlot10 ( 1630 ), + payloadBusFailureToIOSlot17XCONSlot10 ( 1640 ), + timeSlotInterchangeEquipmentFailure ( 1650 ), + + equipmentFailure ( 1660 ), + highTemperature ( 1670 ), + invalidMACAddress ( 1680 ), + boardFailure ( 1690 ), + diagnosticFailure ( 1700 ), + mediumAccessControlFailure ( 1710 ), + facilityTerminationEquipmentFailure ( 1720 ), + automaticLaserShutoffDueToHighTemperature ( 1730 ), + failureToReleaseFromProtection ( 1740 ), + receiverFailure ( 1750 ), + transmitFailure ( 1760 ), + facilityTerminationEquipmentReceiverMissing ( 1770 ), + facilityTerminationEquipmentTransmitterMissing ( 1780 ), + failureToSwitchToProtection ( 1790 ), + failureToSwitchToProtectionRing ( 1800 ), + + failureToSwitchToProtectionSpan ( 1810 ), + failureToSwitchToProtectionPath ( 1820 ), + fanFailure ( 1830 ), + equipmentUnitPlugIn ( 1840 ), + nePowerFailureAtConnector ( 1850 ), + fuseAlarm ( 1860 ), + synchronizationUnitFailure ( 1870 ), + synchronizationSwitchingEquipmentFailure ( 1880 ), + equipmentUnitUnplugged ( 1890 ), + loopback ( 1900 ), + + ds1LoopbackDueToFEACCommand ( 1910 ), + loopbackCommandSentToFarEndDS1 ( 1920 ), + ds3LoopbackDueToFEACCommand ( 1930 ), + ds3LoopbackCommandSentToFarEnd ( 1940 ), + ds2LoopbackDueToFarEndCommand ( 1950 ), + ds2LoopbackCommandSentToFarEnd ( 1960 ), + facilityLoopback ( 1970 ), + networkLoopback ( 1980 ), + terminalLoopback ( 1990 ), + manuallyCausedAbnormalCondition ( 2000 ), + ethernetBridgeIsNewRootOfSpanningTree ( 2010 ), + ethernetBridgeTopologyChange ( 2020 ), + normalCondition ( 2030 ), + embeddedOperationsChannelFailureLinkDown ( 2040 ), + peerStateMismatch ( 2050 ), + proceduralError ( 2060 ), + improperRemoval ( 2070 ), + duplicateNodeID ( 2080 ), + blsrOutOfSync ( 2090 ), + blsrMultiNodeTableUpdateCompleted ( 2100 ), + protectionUnitNotAvailable ( 2110 ), + performanceMonitorThresholdCrossingAlert ( 2120 ), + protectionSwitch ( 2130 ), + recoveryOrServiceProtectionActionHasBeenInitiated ( 2140 ), + automaticSystemReset ( 2150 ), + automaticUPSRSwitchCausedByAIS ( 2160 ), + automaticUPSRSwitchCausedByLOP ( 2170 ), + automaticUPSRSwitchCausedByUNEQ ( 2180 ), + automaticUPSRSwitchCausedByPDI ( 2190 ), + automaticUPSRSwitchCausedBySFBER ( 2200 ), + automaticUPSRSwitchCausedBySDBER ( 2210 ), + coldRestart ( 2220 ), + forcedSwitchBackToWorking ( 2230 ), + forcedSwitchBackToWorkingRing ( 2240 ), + forcedSwitchBackToWorkingSpan ( 2250 ), + forcedSwitchToProtection ( 2260 ), + + forcedSwitchToProtectionRing ( 2270 ), + forcedSwitchToProtectionSpan ( 2280 ), + workingFacilityOrEquipmentForcedToSwitchToProtectionPath ( 2290 ), + + initializationInitiated ( 2300 ), + lockoutOfProtection ( 2310 ), + lockoutOfProtectionRing ( 2320 ), + lockoutOfProtectionSpan ( 2330 ), + lockoutOfProtectionPath ( 2340 ), + lockoutOfWorking ( 2350 ), + lockoutOfWorkingRing ( 2360 ), + lockoutOfWorkingSpan ( 2370 ), + + manualSystemReset ( 2380 ), + + manualSwitchToInternalClock ( 2390 ), + manualSwitchToPrimaryReference ( 2400 ), + manualSwitchToSecondReference ( 2410 ), + manualSwitchToThirdReference ( 2420 ), + manualSwitchToFourthReference ( 2430 ), + manualSwitchToFifthReference ( 2440 ), + manualSwitchToSixthReference ( 2450 ), + + manualSwitchBackToWorking ( 2460 ), + manualSwitchBackToWorkingRing ( 2470 ), + manualSwitchBackToWorkingSpan ( 2480 ), + manualSwitchToProtection ( 2490 ), + manualSwitchToProtectionRing ( 2500 ), + manualSwitchToProtectionSpan ( 2510 ), + manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath ( 2520 ), + + powerfailRestart ( 2530 ), + ringIsSquelchingTraffic ( 2540 ), + softwareDownloadInProgress ( 2550 ), + + switchToInternalClock ( 2560 ), + switchToPrimaryReference ( 2570 ), + switchToSecondReference ( 2580 ), + switchToThirdReference ( 2590 ), + switchToFourthReference ( 2600 ), + switchToFifthReference ( 2610 ), + switchToSixthReference ( 2620 ), + + systemReboot ( 2630 ), + switchedBackToWorking ( 2640 ), + switchedToProtection ( 2650 ), + warmRestart ( 2660 ), + ringIsInWaitToRestoreState ( 2670 ), + manualSwitchRequest ( 2680 ), + forcedSwitchRequest ( 2690 ), + lockoutSwitchRequest ( 2700 ), + + rmonHistoriesAndAlarmsResetReboot ( 2710 ), + rmonThresholdCrossingAlarm ( 2720 ), + alarmsSuppressedByUserCommand ( 2730 ), + alarmsSuppressedForMaintenance ( 2740 ), + switchingMatrixModuleFailure ( 2750 ), + lanConnectionPolarityReversed ( 2760 ), + autonomousPMReportMessageInhibited ( 2780 ), + ioSlotToXCONCommunicationFailure ( 2790 ), + + -- Intentional gap + + stsPathTraceIdentifierMismatch ( 2800 ), + nePowerFailureAtConnectorA ( 2810 ), + nePowerFailureAtConnectorB ( 2820 ), + freeMemoryOnCardVeryLow ( 2830 ), + freeMemoryOnCardNearZero ( 2840 ), + + exerciseRequestOnRing ( 2850 ), + exerciseRequestOnSpan ( 2860 ), + squelchingPath ( 2870 ), + extraTrafficPreempted ( 2880 ), + + farEndLockoutOfWorkingRing ( 2890 ), + farEndLockoutOfWorkingSpan ( 2900 ), + farEndLockoutOfProtectionRing ( 2910 ), + farEndLockoutOfProtectionAllSpans ( 2920 ), + + farEndWorkingFacilityForcedToSwitchToProtectionRing ( 2930 ), + farEndWorkingFacilityForcedToSwitchToProtectionSpan ( 2940 ), + + farEndManualSwitchOfWorkingFacilityToProtectionRing ( 2950 ), + farEndManualSwitchOfWorkingFacilityToProtectionSpan ( 2960 ), + farEndExercisingRing ( 2970 ), + farEndExercisingSpan ( 2980 ), + farEndBERThresholdPassedForSignalFailureRing ( 2990 ), + farEndBERThresholdPassedForSignalFailureSpan ( 3000 ), + farEndBERThresholdPassedForSignalDegradeRing ( 3010 ), + farEndBERThresholdPassedForSignalDegradeSpan ( 3020 ), + apsChannelFarEndProtectionLineSignalDegrade ( 3030 ), + + ringSwitchIsActiveOnTheEastSide ( 3040 ), + ringSwitchIsActiveOnTheWestSide ( 3050 ), + spanSwitchIsActiveOnTheEastSide ( 3060 ), + spanSwitchIsActiveOnTheWestSide ( 3070 ), + + uniDirectionalFullPassThroughIsActive ( 3080 ), + biDirectionalFullPassThroughIsActive ( 3090 ), + + kBytesPassThroughIsActive ( 3100 ), + ringIsSegmented ( 3110 ), + ringTopologyIsUnderConstruction ( 3120 ), + + lockoutOfProtectionAllSpans ( 3130 ), + farEndOfFiberIsProvisionedWithDifferentRingID ( 3140 ), + bothEndsOfFiberProvisionedAsEastOrBothAsWest ( 3150 ), + securityInvalidLoginUsernameSeeAuditTrail ( 3160 ), + + autonomousMessagesInhibited ( 3170 ), + trafficStormOnLANLANTemporarilyDisabled ( 3180 ), + + reptdbchgMessagesInhibited ( 3190 ), + securityUserIDHasExpired ( 3200 ), + partialFanFailure ( 3210 ), + forcedSwitchRequestOnRing ( 3220 ), + forcedSwitchRequestOnSpan ( 3230 ), + lockoutSwitchRequestOnRing ( 3240 ), + lockoutSwitchRequestOnSpan ( 3250 ), + manualSwitchRequestOnRing ( 3260 ), + manualSwitchRequestOnSpan ( 3270 ), + + communicationFailurePeerToPeerSlotControlBusA ( 3280 ), + communicationFailurePeerToPeerSlotControlBusB ( 3290 ), + controllerAToShelfSlotCommunicationFailure ( 3300 ), + controllerBToShelfSlotCommunicationFailure ( 3310 ), + + interconnectionEquipmentFailureWorkingPayloadBus ( 3320 ), + interconnectionEquipmentFailureProtectPayloadBus ( 3330 ), + inhibitSwitchToProtectRequestOnEquipment ( 3340 ), + inhibitSwitchToWorkingRequestOnEquipment ( 3350 ), + + berThresholdExceededForSignalDegradeLine ( 3360 ), + berThresholdExceededForSignalDegradePath ( 3370 ), + berThresholdExceededForSignalFailureLine ( 3380 ), + berThresholdExceededForSignalFailurePath ( 3390 ), + + exercisingRingSuccessfully ( 3400 ), + exercisingSpanSuccessfully ( 3410 ), + spanIsInWaitToRestoreState ( 3420 ), + + exerciseRequestOnRingFailed ( 3430 ), + exerciseRequestOnSpanFailed ( 3440 ), + farEndLockoutOfProtectionSpan ( 3450 ), + + manufacturingDataMemoryEEPROMFailure ( 3460 ), + replaceableEquipmentOrUnitIsMissing ( 3470 ), + softwareDownloadFailed ( 3480 ), + extraTrafficPCADropped ( 3490 ), + + etherTxOversubscribed ( 3500 ), + etherRxOverSubscribed ( 3510 ), + etherTxExcessFlowCtrl ( 3520 ), + etherRxExcessFlowCtrl ( 3530 ), + transportLayerFailure ( 3540 ), + etherTxUnderrun ( 3550 ), + + synchronizationReferenceFrequencyOutOfBounds ( 3560 ), + ntpOrSntpHostFailure ( 3570 ), + peerCardNotResponding ( 3580 ), + alarmsAndEventsSuppressedForThisObject ( 3590 ), + ds3FrameFormatMismatch ( 3600 ), + + waitToRestore ( 3610 ), + extremeHighVoltBatteryA ( 3620 ), + extremeLowVoltBatteryA ( 3630 ), + extremeHighVoltBatteryB ( 3640 ), + extremeLowVoltBatteryB ( 3650 ), + iosConfigCopyFailed ( 3660 ), + iosConfigCopyInProgress ( 3670 ), + iosConfigCopySuccess ( 3680 ), + + -- 3660 through 3700 reserverd for R3.3.x releases + + signalingUnableToSetupCircuit ( 3710 ), + errorInStartupConfig ( 3712 ), + noStartupConfig ( 3714 ), + needToSaveRunningConfig ( 3716 ), + invalidAlarm ( 3718 ), + rsvpHelloFSMToNeighborDown ( 3720 ), + securityInvalidLoginUsername ( 3722 ), + databaseBackupFailed ( 3724 ), + databaseRestoreFailed ( 3726 ), + lmpHelloFSMToControlChannelDown ( 3730 ), + lmpNeighborDiscoveryHasFailed ( 3740 ), + unauthorizedIncomingSignalingRequest ( 3750 ), + auditLog80PercentFull ( 3760 ), + moduleCommunicationFailure ( 3762 ), + auditLog100PercentFullOldestRecordsWillBeLost ( 3764 ), + standbyDatabaseOutOfSync ( 3766 ), + redundantPowerCapabilityLost ( 3768 ), + forcedSwitchToPrimaryReference ( 3770 ), + forcedSwitchToSecondReference ( 3780 ), + forcedSwitchToThirdReference ( 3790 ), + forcedSwitchToInternalClock ( 3800 ), + industrialHighTemperature ( 3805 ), + + timSectionTraceIdentifierMismatchFailure ( 4000 ), + aisMultiplexSectionAlarmIndicationSignal ( 4010 ), + rdiMultiplexSectionRemoteDefectOrAlarmIndication ( 4020 ), + timHighOrderTraceIdentifierMismatchFailure ( 4030 ), + aisAdministrationUnitAlarmIndicationSignal ( 4040 ), + lopAdministrationUnitLossOfPointer ( 4050 ), + slmfUnequippedHighOrderPathUnequipped ( 4060 ), + slmfPLMHighOrderPathLabelMismatch ( 4070 ), + rdiHighOrderRemoteDefectOrAlarmIndication ( 4080 ), + lopTributaryUnitLossOfPointer ( 4090 ), + aisTributaryUnitAlarmIndicationSignal ( 4100 ), + slmfUnequippedLowOrderPathUnequipped ( 4110 ), + slmfPLMLowOrderPathLabelMismatch ( 4120 ), + timLowOrderTraceIdentifierMismatchFailure ( 4130 ), + rfiLowOrderRemoteFailureOrAlarmIndication ( 4140 ), + g811PrimaryReferenceClockTraceable ( 4150 ), + g812TransitNodeClockTraceable ( 4160 ), + g812LocalNodeClockTraceable ( 4170 ), + g813SynchronousEquipmentTimingSourceTraceable ( 4180 ), + e1LoopbackDueToFEACCommand ( 4190 ), + e1LoopbackCommandSentToFarEnd ( 4200 ), + e3LoopbackDueToFEACCommand ( 4210 ), + farEndMultipleE1LOSDetectedOnE3 ( 4220 ), + farEndE1EqptFailNonServiceAffecting ( 4230 ), + farEndE1EqptFailServiceAffecting ( 4240 ), + farEndSingleE1LOS ( 4250 ), + farEndE3EqptFailServiceAffecting ( 4260 ), + e3LoopbackCommandSentToFarEnd ( 4270 ), + farEndE3EqptFailNonServiceAffecting ( 4280 ), + lowVoltBatteryA ( 4290 ), + highVoltBatteryA ( 4300 ), + lowVoltBatteryB ( 4310 ), + highVoltBatteryB ( 4320 ), + msspRingOutOfSync ( 4330 ), + msspMultiNodeTableUpdateCompleted ( 4340 ), + automaticSNCPSwitchCausedByAIS ( 4350 ), + automaticSNCPSwitchCausedByLOP ( 4360 ), + automaticSNCPSwitchCausedByUNEQ ( 4370 ), + automaticSNCPSwitchCausedByPDI ( 4380 ), + automaticSNCPSwitchCausedBySFBER ( 4390 ), + automaticSNCPSwitchCausedBySDBER ( 4400 ), + stmConcatenationError ( 4410 ), + e3IdleCondition ( 4420 ), + channelMSSPInconsistentAPSCode ( 4430 ), + channelMSSPImproperAPSCodeAPS ( 4440 ), + channelMSSPNodeIdMismatchAPS ( 4450 ), + channelMSSPDefaultKAPS ( 4460 ), + channelMSSPConnectionLossAPS ( 4470 ), + minimumClockTraceableSDH ( 4480 ), + lineIsInWaitToRestoreStateSDH ( 4490 ), + berThresholdExceededForSignalDegradeHighOrder ( 4500 ), + berThresholdExceededForSignalFailureHighOrder ( 4510 ), + berThresholdExceededForSignalDegradeLowOrder ( 4520 ), + berThresholdExceededForSignalFailureLowOrder ( 4530 ), + failureToSwitchToProtectionHighOrderPath ( 4540 ), + failureToSwitchToProtectionLowOrderPath ( 4550 ), + lofAdministrationUnitLossOfMultiFrame ( 4560 ), + sdhSpanIsInWaitToRestoreState ( 4570 ), + a8b10bOutOfSync ( 4755 ), + odukPMAlarmIndicationSignal ( 4760 ), + otukAlarmIndicationSignal ( 4765 ), + otukSMBackwardDefectIndication ( 4770 ), + fecUncorrectedWord ( 4780 ), + gccTerminationFailure ( 4785 ), + otukIncomingAlignmentError ( 4790 ), + odukLockedDefectPM ( 4795 ), + lossOfMultiFrame ( 4800 ), + odukOpenConnectionIndication ( 4805 ), + payloadTypeIdentifierMismatch ( 4810 ), + odukTrailTraceIdentifierMismatch ( 4815 ), + otukTrailTraceIdentifierMismatch ( 4820 ), + equipmentHighLaserBias ( 4825 ), + equipmentHighLaserTemp ( 4830 ), + equipmentHighLaserPeltier ( 4835 ), + facilityHighRxPower ( 4840 ), + equipmentHighTxPower ( 4845 ), + equipmentHighTransceiverVoltage ( 4850 ), + equipmentLowLaserBias ( 4855 ), + equipmentLowLaserTemp ( 4860 ), + equipmentLowLaserPeltier ( 4865 ), + facilityLowRxPower ( 4870 ), + equipmentLowTxPower ( 4875 ), + equipmentLowTransceiverVoltage ( 4880 ), + equipmentRxLocked ( 4885 ), + equipmentSquelched ( 4890 ), + equipmentTxLocked ( 4895 ), + otukSignalFailure ( 4900 ), + odukSignalFailure ( 4905 ), + otukSignalDegrade ( 4910 ), + odukSignalDegrade ( 4915 ), + pluggablePortMissing ( 4920 ), + pluggablePortRateMismatch ( 4925 ), + pluggablePortSecurityCodeMismatch ( 4930 ), + tciNotSelected ( 4935 ), + tci1ClockFailure ( 4940 ), + odukPMBackwardDefectIndication ( 4945 ), + odukTCM1BackwardDefectIndication ( 4950 ), + odukTCM2BackwardDefectIndication ( 4955 ), + equipmentHighRxTemperature ( 4960 ), + equipmentLowRxTemperature ( 4965 ), + tci2ClockFailure ( 4970 ), + equipmentWavelengthMismatch ( 4975 ), + dspCommunicationFailure ( 4980 ), + dspFailure ( 4985 ), + laserApproachingEndOfLife ( 5000 ), + crossconnectLoopback ( 5010 ), + adminLogoutOfUser ( 5020 ), + userLockedOut ( 5030 ), + adminLockoutOfUser ( 5040 ), + adminLockoutClear ( 5050 ), + invalidLoginUsername ( 5060 ), + securityInvalidLoginPassword ( 5070 ), + securityInvalidLoginLockedOut ( 5080 ), + securityInvalidLoginAlreadyLoggedOn ( 5090 ), + loginOfUser ( 5100 ), + automaticLogoutOfIdleUser ( 5110 ), + logoutOfUser ( 5120 ), + enhancedRemoteFailureIndicationPathServer ( 5200 ), + enhancedRemoteFailureIndicationPathConnectivity ( 5210 ), + enhancedRemoteFailureIndicationPathPayload ( 5220 ), + firewallHasBeenDisabled ( 5230 ), + securityIntrusionDetPwd ( 5240 ), + securityIntrusionDetUser ( 5250 ), + connectionEquipmentMismatch ( 5260 ), + disableInactiveUser ( 5270 ), + disableInactiveClear ( 5280 ), + batteryFailure ( 5290 ), + extremeHighVolt ( 5300 ), + extremeLowVolt ( 5310 ), + highVolt ( 5320 ), + lowVolt ( 5330 ), + suspendUser ( 5340 ), + suspendUserClear ( 5350 ), + lineDccTerminationFailure ( 5360 ), + multiplexSectionDccTerminationFailure ( 5370 ), + gigaBitEthernetOutOfSync ( 5380 ), + sequenceMismatch ( 5390 ), + lossOfAlignment ( 5400 ), + outOfUseByAdministrativeCommand ( 5410 ), + outOfUseTransportFailure ( 5420 ), + vcatGroupDown ( 5430 ), + vcatGroupDegraded ( 5440 ), + vcatGroupIncomplete ( 5450 ), + alarmIndicationSignalInTX ( 5460 ), + remoteAlarmIndicationInTX ( 5470 ), + kByteAPSChannelFailure ( 5480 ), + apsInvalidMode ( 5490 ), + ipAddressAlreadyInUseWithinTheSameDccArea ( 5500 ), + nodeNameInUseWithinTheSameDccArea ( 5510 ), + rearPanelEthernetLinkRemoved ( 5520 ), + manualSwitchToProtectResultedInNoTrafficSwitch ( 5530 ), + manualSwitchBackToWorkingResultedInNoTrafficSwitch ( 5540 ), + forcedSwitchToProtectResultedInNoTrafficSwitch ( 5550 ), + forcedSwitchBackToWorkingResultedInNoTrafficSwitch ( 5560 ), + duplicateSerialNumberDetectedOnAPluggableEntity ( 5570 ), + lossOfSignalForOpticalChannel ( 5600 ), + encapsulationMismatchPath ( 5610 ), + encapsulationMismatchVT ( 5620 ), + encapsulationMismatchHighOrderPath ( 5630 ), + encapsulationMismatchLowOrderPath ( 5640 ), + gfpUserPayloadMismatch ( 5650 ), + gfpFibreChannelDistanceExtensionMismatch ( 5660 ), + gfpFibreChannelDistanceExtensionBufferStarvation ( 5670 ), + gfpFibreChannelDistanceExtensionCreditStarvation ( 5680 ), + automaticWdmAnsFinished ( 5690 ), + gfpClientSignalFailDetected ( 5700 ), + gfpLossOfFrameDelineation ( 5710 ), + gfpExtensionHeaderMismatch ( 5730 ), + incomingOverheadSignalAbsent ( 5740 ), + opticalSafetyRemoteInterlockOn ( 5750 ), + automaticPowerControlCorrectionSkipped ( 5770 ), + apcCannotSetValueDueToRangeLimits ( 5780 ), + lcasVcgMemberTxSideInAddState ( 5790 ), + farEndManualSwitchBackToWorkingSpan ( 5800 ), + farEndForcedSwitchBackToWorkingSpan ( 5810 ), + universalTransponderModuleHardwareFailure ( 5820 ), + universalTransponderModuleCommunicationFailure ( 5830 ), + pluginModuleRangeSettingsMismatch ( 5840 ), + lcasVcgMemberTxSideInDnuState ( 5850 ), + lcasControlWordCrcCheckFailure ( 5860 ), + lcasVcgMemberRxSideInFailState ( 5870 ), + signalLossOnDataInterface ( 5880 ), + synchronizationLossOnDataInterface ( 5890 ), + portFAIL ( 5900 ), + unreachablePortTargetPower ( 5910 ), + portAddPowerDegradeLow ( 5920 ), + portAddPowerDegradeHigh ( 5930 ), + portAddPowerFailLow ( 5940 ), + portAddPowerFailHigh ( 5950 ), + automaticPowerControlTerminatedOnManualRequest ( 6000 ), + oduk1AlarmIndicationSignal ( 6010 ), + oduk2AlarmIndicationSignal ( 6020 ), + oduk3AlarmIndicationSignal ( 6030 ), + oduk4AlarmIndicationSignal ( 6040 ), + temperatureReadingMismatchBetweenSCCards ( 6050 ), + voltageReadingMismatchBetweenSCCards ( 6060 ), + alarmsSuppressedonOutOfGroupVcatMember ( 6070 ), + blsrSoftwareVersionMismatch ( 6080 ), + optimized1Plus1ApsPrimaryFacility ( 6090 ), + optimized1Plus1ApsPrimarySectionMismatch ( 6100 ), + optimized1Plus1ApsInvalidPrimarySection ( 6110 ), + compositeClockHighLineVoltage ( 6120 ), + berThresholdExceededForSignalDegradeVt ( 6130 ), + berThresholdExceededForSignalFailureVt ( 6140 ), + spanLengthOutOfRange ( 6150 ), + idleSignalCondition ( 6170 ), + idleSignalConditionInTx ( 6180 ), + vtPathTraceIdentifierMismatch ( 6190 ), + lossOfFrameInTX ( 6200 ), + provisioningMismatch ( 6210 ), + sectionTraceIdentifierMismatch ( 6220 ), + regeneratorSectionTraceIdentifierMismatch ( 6230 ), + switchingMatrixModuleFailureWorking ( 6240 ), + switchingMatrixModuleFailureProtect ( 6250 ), + slotCommunicationDisabled ( 6260 ), + sessionTimeLimitExpired ( 6270 ), + userPasswordChangeRequired ( 6280 ), + isisAdjacencyFailure ( 6290 ), + msspSoftwareVersionMismatch ( 6300 ), + remoteAuthenticationFailSeeAuditLog ( 6310 ), + ringIsSquelchingStsTraffic ( 6330 ), + ringIsSquelchingVtTraffic ( 6340 ), + archiveOfAuditLogFailed ( 6350 ), + rprWrapped ( 6360 ), + shelfCommunicationFailure ( 6370 ), + duplicatedShelfIdentifier ( 6380 ), + softwareMismatch ( 6390 ), + lmpFailure ( 6400 ), + opticalTerminationIncomplete ( 6410 ), + forwardDefectIndication ( 6420 ), + payloadMissingIndication ( 6430 ), + spanMeasurementCannotBePerformed ( 6440 ), + ringIsSquelchingHighOrderTraffic ( 6450 ), + ringIsSquelchingLowOrderTraffic ( 6460 ), + badPacketCountExceedsThreshold ( 6470 ), + linkLayerKeepAliveFailure ( 6480 ), + autonegotiationRemoteFailureIndication ( 6490 ), + trailSignalFail ( 6500 ), + ds1LoopbackCommandSentToFarEnd ( 6510 ), + multiplexSectionSignalDegraded ( 6520 ), + multiplexSectionExcessiveErrors ( 6530 ), + highOrderPathSignalDegraded ( 6540 ), + highOrderPathExcessiveErrors ( 6550 ), + lowOrderPathSignalDegraded ( 6560 ), + lowOrderPathExcessiveErrors ( 6570 ), + regeneratorSectionDccTerminationFailure ( 6580 ), + networkMemoryPoolLow ( 6590 ), + ospfRoutingTableOverflow ( 6600 ), + autoLaserShutdownDisabled ( 6610 ), + rprProtectionIsActive ( 6630 ), + maxRPRStationNumberExceeded ( 6640 ), + rprProtectionConfigurationMismatched ( 6650 ), + reservedBandwidthLinkRateExceededOnRinglet0 ( 6660 ), + reservedBandwidthLinkRateExceededOnRinglet1 ( 6670 ), + rprInterfaceInPassThroughMode ( 6680 ), + rprPeerNodeIsMissing ( 6690 ), + rprRiFailure ( 6700 ), + rprSignalFailure ( 6710 ), + rprSignalDegrade ( 6720 ), + interlinkFailure ( 6730 ), + apcWrongGain ( 6740 ), + rprSpanMismatch ( 6750 ), + efmRemoteFaultIndicationCriticalEvent ( 6760 ), + efmRemoteFaultIndicationDyingGasp ( 6770 ), + efmRemoteFaultIndicationLinkFault ( 6780 ), + efmLinkMonitoringErroredSymbolPeriodEvent ( 6790 ), + efmLinkMonitoringErroredFrameEvent ( 6800 ), + efmLinkMonitoringErroredFramePeriodEvent ( 6810 ), + efmLinkMonitoringErroredFrameSecondsSummary ( 6820 ), + efmRemoteLoopbackRequestFailed ( 6830 ), + fastAutomaticProtectionSwitching ( 6840 ), + fastAutomaticProtectionSwitchingConfigMismatch ( 6850 ), + lcasSinkGroupError ( 6860 ), + lcasVcgMemberRxSideInDnuState ( 6870 ), + fcDistanceExtFuncNotEstablished ( 6880 ), + nonCiscoPPMInserted ( 6890 ), + unqualifiedPPMInserted ( 6900 ), + ftaMismatch ( 6910 ), + cardPortsUnableToProvideProtection ( 6920 ), + lmpSignalDegrade ( 6930 ), + lmpSignalFailure ( 6940 ), + lmpUnallocatedDataLink ( 6950 ), + frontPortLinkLoss ( 6960 ), + bertEnbl ( 6970 ), + bertSyncFail ( 6975 ), + workQueueFull ( 6980 ), + equipmentPowerFailureAtConnectorA ( 7000 ), + equipmentPowerFailureAtConnectorB ( 7005 ), + equipmentPowerFailureAtReturnConnectorA ( 7010 ), + equipmentPowerFailureAtReturnConnectorB ( 7015 ), + bridgeAndRollHasOccurred ( 7055 ), + bridgeAndRollIsPendingAValidSignal ( 7060 ), + clockBusFailureTscA ( 7160 ), + clockBusFailureTscB ( 7165 ), + ospfHelloFail ( 7185 ), + openIOSlots ( 7200 ), + lossOfClockFromMateShelfController ( 7210 ), + virtualLanAlarmIndiacationSignal ( 7225 ), + dcuLossFailure ( 7230 ), + ochncMaintenance ( 7235 ), + ramanLaserShutdown ( 7240 ), + losOfRamanSignal ( 7245 ), + mcastMacTableFull ( 7250 ), + multicastMacAddressAliasing ( 7255 ), + ramanPwrProtOn ( 7260 ), + cppPeerNotResponding ( 7265 ), + voaControlLoopDisableDueToExcessiveCounterPropagationLight ( 7275 ), + wizardIsRunning ( 7280 ), + ramanGainNotReached ( 7285 ), + pprForwardDefectIndication ( 7295 ), + pprBackwardDefectIndication ( 7300 ), + pprCoordinatedMaintenance ( 7305 ), + pprTriggerThresholdBerExceeded ( 7310 ), + localFault ( 7315 ), + remoteFault ( 7320 ), + efmRemoteLoopbackConfigured ( 7325 ), + efmPeerMissing ( 7330 ), + eqptDegrade ( 7335 ), + excessiveBackPropagation ( 7340 ), + remoteMaintenanceEndPointIsDown ( 7345 ), + crossConnectedCFMService ( 7350 ), + cfmLoop ( 7355 ), + cfmConfigurationError ( 7360 ), + outOfChannelGroupBundle ( 7365 ), + repNeighborAdjacencyFailure ( 7370 ), + repLinkFlapping ( 7375 ), + faultInREPSegment ( 7380 ), + primaryREPEdgePortElected ( 7385 ), + secondaryREPEdgePortElected ( 7390 ), + stcnREPGenerated ( 7395 ), + vlbREPActivated ( 7400 ), + vlbREPTriggerSoakingDelayActive ( 7405 ), + wanSyncloss ( 7410 ), + laserShutdownDueToWavelengthDrift ( 7415 ), + manualLaserRestart ( 7420 ), + laserShutdownDueToNonCiscoPPMInserted ( 7425 ), + ethernetOSCTerminationFailure ( 7430 ), + softwareSignatureVerificationFailed ( 7445 ), + protectVolumeSoftwareSignatureVerificationFailed ( 7450 ), + activeVolumeSoftwareSignatureVerificationFailed ( 7455 ), + peerPortClientSignalFailDetected (7460), + channelShutdownDueToWavelengthDrift ( 7465 ), + usbWriteFailure ( 7475 ), + usbSyncInProgress ( 7480 ), + autoSensingUnableToDetectValidPayload (7485), + payloadAutoSensingInProgress (7490), + gfpClientSignalFailDetectedDueToSigloss (7495), + gfpClientSignalFailDetectedDueToSyncloss (7500), + pmdDegrade (7510), + standbyTccNEClockIsInternalClock ( 7515 ), + chromaticDispersionValue ( 7520 ), + packetTransportServiceFailed ( 7525 ), + satellitePanelDiscoveryFailure ( 7530 ), + satellitePanelActiveLinkFailure ( 7535 ), + satellitePanelCommunicationFailure ( 7540 ), + satellitePanelImproperConfiguration ( 7545 ), + satellitePanelFanMismatchOfEquipmentAndAttributes ( 7550 ), + satellitePanelFanFailure ( 7555 ), + satellitePanelPartialFanFailure ( 7560 ), + satellitePanelFANManufacturingDataMemoryEEPROMFailure ( 7565 ), + satellitePanelFANUnitIsMissing ( 7570 ), + satellitePanelIndustrialHighTemperature ( 7575 ), + satellitePanelHighTemperature ( 7580 ), + satellitePanelBatteryFailureA ( 7585 ), + plannedSwitchOver ( 7590 ), + protectionCardConfigurationMismatch ( 7595 ), + routerProcessorSwitchOver ( 7600 ), + runningLowOnResources ( 7605 ), + noMoreResourcesAreAvailable ( 7610 ), + esmcFailure ( 7615 ), + licenseWillExpireWithin24Hours ( 7620 ), + licenseWillExpireAnytimeAfter1DayButBefore14Days ( 7625 ), + licenseIsExpired ( 7630 ), + licenseCountViolation ( 7635 ), + temporaryLicenseIsInUse ( 7640 ), + evaluationLicenseIsInUse ( 7645 ), + licenseIsMissing ( 7650 ), + pseudowireDown ( 7655 ), + workingPseudowireControlPlaneDown ( 7660 ), + protectPseudowireControlPlaneDown ( 7665 ), + workingPseudowireConnectivityCheckDown ( 7670 ), + protectPseudowireConnectivityCheckDown ( 7675 ), + pseudowireTrafficSwitchedToProtection ( 7680 ), + workingPseudowireLocalAcTxPortFault ( 7685 ), + protectPseudowireLocalAcTxPortFault ( 7690 ), + workingPseudowireLocalAcRxPortFault ( 7695 ), + protectPseudowireLocalAcRxPortFault ( 7700 ), + workingPseudowireRemoteAcTxPortFault ( 7705 ), + protectPseudowireRemoteAcTxPortFault ( 7710 ), + workingPseudowireRemoteAcRxPortFault ( 7715 ), + protectPseudowireRemoteAcRxPortFault ( 7720 ), + slaThresholdCrossAlert ( 7725 ), + protectLocalPseudowireNotForwarding ( 7730 ), + workingPseudowireNotForwarding ( 7735 ), + protectPseudowireNotForwarding ( 7740 ), + tpTunnelDown ( 7745 ), + workingLabelSwitchedPathDown ( 7750 ), + protectLabelSwitchedPathDown ( 7755 ), + workingLabelSwitchedPathAlarmIndicationSignal ( 7760 ), + protectLabelSwitchedPathAlarmIndicationSignal ( 7765 ), + workingLabelSwitchedPathRemoteDefectIndication ( 7770 ), + protectLabelSwitchedPathRemoteDefectIndication ( 7775 ), + bidirectionalForwardDetectionDown ( 7780 ), + tpTrafficSwitchedFromWorkingToProtection ( 7785 ), + workingTpLockout ( 7790 ), + protectTpLockout ( 7795 ), + ethernetFlowPointFailed ( 7800 ), + teTunnelDown ( 7805 ), + macSystemLimitReached ( 7810 ), + macBridgeDomainLimitReached ( 7815 ), + autoSensingDisabled ( 7820 ), + smBackwardIncomingAlignmentError ( 7825 ), + resourceAllocationFailed ( 7830 ), + lossOfDFBSignal ( 7835 ), + workingLabelSwitchedPathLinkDownIndication ( 7840 ), + protectLabelSwitchedPathLinkDownIndication ( 7845 ), + workingLabelSwitchedPathLockReport ( 7850 ), + protectLabelSwitchedPathLockReport ( 7855 ), + satellitePanelBatteryFailureB ( 7860 ), + highBitErrorRate (7865), + backPanelFacilityLoopback (7870), + backPanelTerminalLoopback (7875), + trunkPayloadTypeMismatch (7880), + invalidMuxponderConfiguration (7885), + coolingProfileMismatch (7890), + trunkOduAlarmIndicationSignal (7895), + companionCardMissing (7900), + controlPlaneUnverifiedClearedAlarmsPresent (7905), + powerConsumptionLimitHasCrossed (7910), + masterKeyExchangeFailed (7915), + unitHighTemperature (7930), + overTemperatureUnitProtected (7935), + seqMismatchCount (7945), + keyProgramOnAlteraFpgaFailed (7960), + duplicateNodeControllerDetected (7970), + restorationInProg (7975), + ramanPumpsCalibrationProcedureIsRunning (7980), + ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes (7985), + odukTCM1AlarmIndicationSignal ( 13100 ), + odukTCM2AlarmIndicationSignal ( 13105 ), + odukLockedDefectTCM1 ( 13110 ), + odukLockedDefectTCM2 ( 13115 ), + otukLossOfFrame ( 13120 ), + odukOpenConnectionIndicationTCM1 ( 13125 ), + odukOpenConnectionIndicationTCM2 ( 13130 ), + odukTrailTraceIdentifierMismatchTCM1 ( 13135 ), + odukTrailTraceIdentifierMismatchTCM2 ( 13140 ), + odukSignalFailureTCM1 ( 13145 ), + odukSignalFailureTCM2 ( 13150 ), + odukSignalDegradeTCM1 ( 13155 ), + odukSignalDegradeTCM2 ( 13160 ), + lossOfChannel ( 13165 ), + fecMismatch ( 13170 ), + timSectionMonitorTraceIdentifierMismatchFailure ( 13175 ), + automaticLaserShutdown ( 13180 ), + shutterInsertionLossVariationDegradeLow ( 13200 ), + opticalChannelDeactivationFailure ( 13205 ), + shutterInsertionLossVariationDegradeHigh ( 13210 ), + networkTopologyIncomplete ( 13215 ), + pluginModuleCommunicationFailure ( 13220 ), + opticalNetworkTypeMismatch ( 13225 ), + opticalPowerDegradeLow ( 13230 ), + automaticPowerControlFailure ( 13235 ), + opticalPowerDegradeHigh ( 13240 ), + automaticPowerControlDisabled ( 13245 ), + opticalPowerFailureLow ( 13250 ), + ringIdMismatch ( 13255 ), + opticalPowerFailureHigh ( 13260 ), + lossOfContinuity ( 13270 ), + variableOpticalAttenuatorDegradeLow ( 13280 ), + variableOpticalAttenuatorDegradeHigh ( 13290 ), + variableOpticalAttenuatorFailureLow ( 13300 ), + variableOpticalAttenuatorFailureHigh ( 13310 ), + laserBiasDegrade ( 13320 ), + laserBiasFailure ( 13330 ), + laserTemperatureDegrade ( 13340 ), + opticalAmplifierGainDegradeLow ( 13350 ), + opticalAmplifierGainDegradeHigh ( 13360 ), + opticalAmplifierGainFailureLow ( 13370 ), + opticalAmplifierGainFailureHigh ( 13380 ), + opticalChannelConnectionFailure ( 13390 ), + opticalChannelIncomplete ( 13395 ), + opticalChannelActivationFailure ( 13400 ), + laserAutoPowerReduction ( 13410 ), + caseTemperatureDegrade ( 13420 ), + fiberTemperatureDegrade ( 13430 ), + shutterOpen ( 13440 ), + awgTemperatureDegrade ( 13450 ), + awgTemperatureFailure ( 13460 ), + awgOverTemperature ( 13470 ), + opticalAmplifierInitialization ( 13480 ), + awgWarmUp ( 13490 ), + incSigloss ( 13510 ), + incSyncloss ( 13515 ), + incGfpOutOfFrame ( 13520 ), + incGfpSigLoss ( 13525 ), + incGfpSyncLoss ( 13530 ) +} + +-- Cerent454ObjectType ::= TEXTUAL-CONVENTION +-- DISPLAY-HINT "d" +-- STATUS current +-- DESCRIPTION +-- "Very similar to the alarm type TC, except this is +-- used for object type display" +-- SYNTAX INTEGER { +-- objectNone ( 1 ), +-- objectEntity ( 10 ), +-- objectInterface ( 20 ), +-- objectOspf ( 30 ), +-- objectProtectionGroup ( 40 ), +-- objectSdccTerm ( 50 ), +-- objectSync ( 60 ), +-- objectSecurity ( 70 ), +-- objectTopologyElement ( 80 ), +-- objectSystem ( 90 ), +-- objectStsConnection ( 100 ), +-- objectVtConnection ( 110 ), +-- objectSonetPool ( 120 ), +-- objectEtherBridge ( 130 ), +-- objectSpanningTree ( 140 ), +-- objectVlan ( 150 ), +-- objectCircuit ( 160 ) +-- } + +Cerent454EntityClass ::= TEXTUAL-CONVENTION + -- DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "This is the TC used to find out to which cerent454EntityClass + an alarm belongs to." + SYNTAX INTEGER { + unknownEntity ( 1 ), + ne ( 10 ), + backplane ( 30 ), + eqpt ( 50 ), + port ( 60 ), + ocn ( 70 ), + stmn ( 71 ), + aip ( 80 ), + fanTray ( 90 ), + crs ( 100 ), + ds3 ( 110 ), + almExpPanel ( 120 ), + almIfExtnsn ( 130 ), + stsMon ( 140 ), + vcMonHp ( 141 ), + dwdmClient ( 150 ), + stsTerm ( 160 ), + vcTermHp ( 161 ), + dwdmTrunk ( 170 ), + dwdmOptics ( 180 ), + psSts ( 190 ), + rsms ( 200 ), + xcSts ( 210 ), + bits ( 220 ), + dwdmFec ( 230 ), + neSynchRef ( 240 ), + dwdm8b10b ( 250 ), + extSynchRef ( 260 ), + dwdmOtn ( 270 ), + envAlrm ( 280 ), + envCtrl ( 290 ), + neRing ( 360 ), + ds1 ( 390 ), + vtMon ( 410 ), + vcMonLp ( 411 ), + vtTerm ( 420 ), + vcTermLP ( 421 ), + fUdc ( 430 ), + msUdc ( 440 ), + spareSdcc ( 450 ), + ucpCircuit ( 480 ), + ucpIpcc ( 490 ), + ucpNeighbor ( 500 ), + ec1 ( 510 ), + ps ( 520 ), + psVt ( 530 ), + e100t ( 540 ), + e1000t ( 550 ), + etherBridge ( 560 ), + e1 ( 600 ), + e3 ( 630 ), + e4 ( 640 ), + stm1E ( 650 ), + ds3i ( 660 ), + g1000 ( 670 ), + ml100t ( 680 ), + ml1000 ( 690 ), + dwdmSfp ( 700 ), + dwdmScl ( 710 ), + dwdmTcm1 ( 720 ), + dwdmTcm2 ( 730 ), + dwdmOcn ( 740 ), + dwdmSm ( 750 ), + dwdmPm ( 760 ), + dwdmTcm ( 770 ), + pwr ( 780 ), + stsTermVcat ( 790 ), + vtTermVcat ( 800 ), + vcatGroup ( 810 ), + fcmr ( 820 ), + entOptics ( 830 ), + ce100t ( 840 ), + ppm ( 850 ), + twor ( 860 ), + isc ( 870 ), + escon ( 880 ), + bic ( 890 ), + gfp ( 900 ), + gige ( 910 ), + pos ( 920 ), + cap ( 930 ), + dwdmData ( 940 ), + logFac ( 950 ), + ge ( 960 ), + fc ( 970 ), + ec1p1 ( 980 ), + mlFx ( 990 ), + ochTerm ( 1000 ), + shelf ( 1010 ), + ce1000 ( 1020 ), + cemr ( 1030 ), + lmp ( 1040 ), + lmpControlChannel ( 1050 ), + lmpTeLink ( 1060 ), + lmpDataLink ( 1070 ), + rpr ( 1080 ), + ether ( 1090 ), + mlmr ( 1100 ), + otu ( 1110 ), + aots ( 3200 ), + ots ( 3210 ), + oms ( 3220 ), + och ( 3230 ), + osc ( 3240 ), + ochnc ( 3250 ), + ib ( 3260 ), + chgrp ( 3270 ), + hdlc ( 3280 ), + msISC ( 3290 ), + ecu ( 3300 ), + lcdFlash ( 3310 ), + usb ( 3320 ), + fe ( 3330 ), + odu0 ( 3350 ), + odu1 ( 3360 ) + +} + +-- ************************************************************** +cerent454Objects OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The cerent454 specific objects themselves" + ::= { cerent454Mib 20 } + +-- ************************************************************** +-- All Cisco OTBU generic objects definitions +-- These will be available for all Cisco OTBU products. Hence +-- they are defined once under generic category. + +cerent454CommonObjectsGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The group to combine all the Cisco OTBU common + objects" + ::= { cerentCommonObjects 10 } + +cerent454EnableNotification OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable indicates whether the system produces + notifications. A value=FALSE will prevent notifications + from being sent by this system." + DEFVAL { true } + ::= { cerent454CommonObjectsGroup 10 } + +cerent454NodeTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates current local time as reflected by + the Cisco OTBU equipment. The format this scalar is + YYYYMMDDhhmmss{S/D}. E.g., + 20011103133453D means 1:34:53 PM PDT on 03/Nov/2001 + 19990614095436S means 9:54:36 AM PST on 14/Jun/1999. + If the last octet is S then the time is standard time. + Otherwise it is D to indicate it is daylight saving + time, if applicable" + ::= { cerent454CommonObjectsGroup 20 } + +cerent454SentNotifications OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of v1+v2 notifications sent out + by the agent. Resets to zero after + cold/warm start." + ::= { cerent454CommonObjectsGroup 30 } + +cerent454LastChangeTime OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at the time + a conceptual row is created or deleted + in cerent454AlarmTable " + ::= { cerent454CommonObjectsGroup 40 } + +cerent454MultishelfEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This variable indicates whether the system is configured + in multi-shelf mode or single-shelf mode." + DEFVAL { false } + ::= { cerent454CommonObjectsGroup 50 } + +-- ************************************************************** +-- +cerent454GeneralGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "" + ::= { cerent454Objects 20 } + +cerent454SoftwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the version of software that is + used in Cisco ONS 15454. E.g., 2.2.03" + ::= { cerent454GeneralGroup 10 } + +cerent454AlarmGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The group that will represent all the + alarm info in the Cisco ONS 15454 node" + ::= { cerent454Objects 30 } + +cerent454AlarmCount OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of active alarms in Cisco ONS 15454. + This equals the total number of rows in + cerent454AlarmTable at any time." + ::= { cerent454AlarmGroup 10 } + +cerent454AlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Cerent454AlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table has all currently raised conditions + for the network node. A Condition is a fault or + status detected by hardware or software." + ::= { cerent454AlarmGroup 20 } + +cerent454AlarmEntry OBJECT-TYPE + SYNTAX Cerent454AlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for cerent454AlarmTable" + INDEX { cerent454AlarmIndex, cerent454AlarmType } + ::= { cerent454AlarmTable 1 } + +Cerent454AlarmEntry ::= SEQUENCE { + cerent454AlarmIndex Integer32, + cerent454AlarmObjectType Cerent454EntityClass, + cerent454AlarmSlotNumber Integer32, + cerent454AlarmPortNumber CerentPortNumber, + cerent454AlarmLineNumber Integer32, + cerent454AlarmObjectIndex Integer32, + cerent454AlarmType Cerent454AlarmType, + cerent454AlarmState CerentNotificationClass, + cerent454AlarmTimeStamp TimeStamp, + cerent454AlarmObjectName DisplayString, + cerent454AlarmAdditionalInfo DisplayString, + cerent454AlarmSeverity CerentAlarmSeverity, + cerent454AlarmStatus CerentAlarmStatus, + cerent454AlarmServiceAffecting CerentAlarmServiceAffecting + } + +cerent454AlarmIndex OBJECT-TYPE + SYNTAX Integer32 ( 1..2147483647 ) -- all +ve values + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Identifies each entry in alarm table. + May not start with one and there may be some + missing numbers." + ::= { cerent454AlarmEntry 10 } + +cerent454AlarmObjectType OBJECT-TYPE + SYNTAX Cerent454EntityClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This will indicate what is the type + of the entity which raised this alarm. + ( E.g., DS3, etherBridge, VT-TERM, etc ) + The NMS is expected to use this value + to decide which table to poll for + further info about the alarm" + ::= { cerent454AlarmEntry 20 } + +cerent454AlarmSlotNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This will indicate what is the slot + of the object which raised this alarm. + If not relevant to the alarm, will be + zero." + ::= { cerent454AlarmEntry 30 } + +cerent454AlarmPortNumber OBJECT-TYPE + SYNTAX CerentPortNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This will indicate what is the port + of the object which raised this alarm." + ::= { cerent454AlarmEntry 40 } + +cerent454AlarmLineNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This will indicate what is the port + of the object which raised this alarm. + If not relevant to the alarm, will be + zero." + ::= { cerent454AlarmEntry 50 } + +cerent454AlarmObjectIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Every alarm is raised by an object and + this object is an entry in a specific + table. This is the index of the object + in that table E.g., if the alarm is interface + related, this index is the index of the + interface in the interface table." + ::= { cerent454AlarmEntry 60 } + +cerent454AlarmType OBJECT-TYPE + SYNTAX Cerent454AlarmType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates what the exact nature of the + alarm. See the Cerent454AlarmType TC + for mapping details " + ::= {cerent454AlarmEntry 70 } + +cerent454AlarmState OBJECT-TYPE + SYNTAX CerentNotificationClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies alarm severity and service + affecting status ( SA/NSA ). Only + {minor|major|critical}+{NA|NSA} alarms and + standing conditions will be represented here. + + However, this mib object is included in each + trap dispatched and in the trap this object + can contain all the possible values of + CerentNotificationClass type." + ::= { cerent454AlarmEntry 80 } + +cerent454AlarmTimeStamp OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when this entry was + created. This is accurate only upto a second." + ::= { cerent454AlarmEntry 90 } + +cerent454AlarmObjectName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TL1-style user-visible name which uniquely + identifies an object in the system" + ::= { cerent454AlarmEntry 100 } + +cerent454AlarmAdditionalInfo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Additional information for the alarm object. + In the current version of the MIB, this object + contains the following information :- + + a) Provisioned description for alarms of type + 'failureDetectedExternalToTheNE'. + + This object would be a null string if no + additional information is specified." + ::= { cerent454AlarmEntry 110 } + +cerent454AlarmSeverity OBJECT-TYPE + SYNTAX CerentAlarmSeverity + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies severity of the alarm + being sent out." + + ::= { cerent454AlarmEntry 120 } + +cerent454AlarmStatus OBJECT-TYPE + SYNTAX CerentAlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Represents if the alarm is currently raised + or cleared." + + ::= { cerent454AlarmEntry 130 } + +cerent454AlarmServiceAffecting OBJECT-TYPE + SYNTAX CerentAlarmServiceAffecting + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies whether the alarm that is being + sent out is Service Affecting (SA) or Non- + Service Affecting (NSA)." + + ::= { cerent454AlarmEntry 140 } + + +cerent454ReportedAlarmCount OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of alarms currently reported against Cisco + ONS 15454. This equals the number of rows in + cerent454ReportedAlarmTable." + ::= { cerent454AlarmGroup 30 } + + +cerent454ReportedAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Cerent454ReportedAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table has the list of alarms currently + reported for the Cisco ONS node. It does not + include any cleared alarms. The alarms in this + table are in compliance with Telcordia GR-253. + This means that if a network problem causes two + alarms, such a as loss of frame(LOF) and loss of + signal(LOS), only LOS alarm will be in this table + because it supersedes and replaces the LOF." + ::= { cerent454AlarmGroup 40 } + +cerent454ReportedAlarmEntry OBJECT-TYPE + SYNTAX Cerent454ReportedAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for cerent454ReportedAlarmTable" + INDEX { cerent454ReportedAlarmIndex, cerent454ReportedAlarmType } + ::= { cerent454ReportedAlarmTable 1 } + +Cerent454ReportedAlarmEntry ::= SEQUENCE { + cerent454ReportedAlarmIndex Integer32, + cerent454ReportedAlarmObjectType Cerent454EntityClass, + cerent454ReportedAlarmSlotNumber Integer32, + cerent454ReportedAlarmPortNumber CerentPortNumber, + cerent454ReportedAlarmObjectIndex Integer32, + cerent454ReportedAlarmType Cerent454AlarmType, + cerent454ReportedAlarmTimeStamp TimeStamp, + cerent454ReportedAlarmObjectName DisplayString, + cerent454ReportedAlarmAdditionalInfo DisplayString, + cerent454ReportedAlarmSeverity CerentAlarmSeverity, + cerent454ReportedAlarmStatus CerentAlarmStatus, + cerent454ReportedAlarmServiceAffecting CerentAlarmServiceAffecting + } + +cerent454ReportedAlarmIndex OBJECT-TYPE + SYNTAX Integer32 ( 1..2147483647 ) -- all +ve values + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Identifies each entry in ReportedAlarm table. + May not start with one and there may be some + missing numbers." + ::= { cerent454ReportedAlarmEntry 10 } + +cerent454ReportedAlarmObjectType OBJECT-TYPE + SYNTAX Cerent454EntityClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This will indicate the type + of the entity which raised this alarm. + ( E.g., DS3, etherBridge, VT-TERM, etc ) + The NMS is expected to use this value + to decide which table to poll for + further info about the alarm" + ::= { cerent454ReportedAlarmEntry 20 } + +cerent454ReportedAlarmSlotNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This will indicate what is the slot + of the object which raised this alarm. + If not relevant to the alarm, will be + zero." + ::= { cerent454ReportedAlarmEntry 30 } + +cerent454ReportedAlarmPortNumber OBJECT-TYPE + SYNTAX CerentPortNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This will indicate what is the port + of the object which raised this alarm." + ::= { cerent454ReportedAlarmEntry 40 } + +cerent454ReportedAlarmObjectIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Every alarm is raised by an object and + this object is an entry in a specific + table. This is the index of the object + in that table E.g., if the alarm is interface + related, this is the index of the + interface in the interface table." + ::= { cerent454ReportedAlarmEntry 50 } + +cerent454ReportedAlarmType OBJECT-TYPE + SYNTAX Cerent454AlarmType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the exact nature of the + alarm." + ::= {cerent454ReportedAlarmEntry 60 } + +cerent454ReportedAlarmTimeStamp OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when this entry was + created. This is accurate only upto a second." + ::= { cerent454ReportedAlarmEntry 70 } + +cerent454ReportedAlarmObjectName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TL1-style user-visible name which uniquely + identifies an object in the system" + ::= { cerent454ReportedAlarmEntry 80 } + +cerent454ReportedAlarmAdditionalInfo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Additional information for the alarm object. + In the current version of the MIB, this object + contains the following information :- + + a) Provisioned description for alarms of type + 'failureDetectedExternalToTheNE'. + + This object would be a null string if no + additional information is specified." + ::= { cerent454ReportedAlarmEntry 90 } + +cerent454ReportedAlarmSeverity OBJECT-TYPE + SYNTAX CerentAlarmSeverity + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies severity of the alarm." + + ::= { cerent454ReportedAlarmEntry 100 } + +cerent454ReportedAlarmStatus OBJECT-TYPE + SYNTAX CerentAlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Represents if the alarm is currently raised + or cleared." + + ::= { cerent454ReportedAlarmEntry 110 } + +cerent454ReportedAlarmServiceAffecting OBJECT-TYPE + SYNTAX CerentAlarmServiceAffecting + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies whether the alarm that is being + sent out is Service Affecting (SA) or Non- + Service Affecting (NSA)." + + ::= { cerent454ReportedAlarmEntry 120 } + + +-- All Cisco ONS 15454 Threshold definitions. + +cerent454ThresholdGroup OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The group that will represent all the + threshold info in the Cisco ONS 15454 node" + ::= { cerent454Objects 40 } + +cerent454ThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF Cerent454ThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table holds all the defined + Thresholds. + + This table is currently unimplemented." + + ::= { cerent454ThresholdGroup 10 } + +cerent454ThresholdEntry OBJECT-TYPE + SYNTAX Cerent454ThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Row definition for cerent454ThresholdTable" + INDEX { cerent454ThresholdIndex } + ::= { cerent454ThresholdTable 1 } + +Cerent454ThresholdEntry ::= SEQUENCE { + cerent454ThresholdIndex Integer32, + cerent454ThresholdMonitorType CerentMonitorType, + cerent454ThresholdLocation CerentLocation, + cerent454ThresholdPeriod CerentPeriod, + cerent454ThresholdSetValue Integer32, + cerent454ThresholdCurrentValue Integer32, + cerent454ThresholdDetectType INTEGER + } + +cerent454ThresholdIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) -- Same as IfIndex from IF-MIB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Uniquely identifies each entry in Threshold table. + May not start with one and there will be some + missing numbers." + ::= { cerent454ThresholdEntry 10 } + +cerent454ThresholdMonitorType OBJECT-TYPE + SYNTAX CerentMonitorType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the type of metric monitored." + ::= { cerent454ThresholdEntry 20 } + +cerent454ThresholdLocation OBJECT-TYPE + SYNTAX CerentLocation + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates if it near or far end" + ::= { cerent454ThresholdEntry 30 } + +cerent454ThresholdPeriod OBJECT-TYPE + SYNTAX CerentPeriod + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sampling interval period is indicated here" + ::= { cerent454ThresholdEntry 40 } + +cerent454ThresholdSetValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object will be threshold that was + provisioned by the NMS" + ::= { cerent454ThresholdEntry 50 } + +-- TEXTUAL CONVENTION +-- Description +-- The value of the optical parameter that is being monitored. +-- +-- The range of values varies depending on the type of optical +-- parameter being monitored, as identified by a corresponding +-- object with syntax OpticalParameterType. +-- +-- when the optical parameter being monitored is 'power' or +-- 'acpower', the supported range is from -1000 to 1000, in +-- 1/10ths of dBm. +-- Example: Actual power of -40 dbm is represented as -400. +-- Actual power level of +30 dBm is represented as 300. +-- +-- When the optical parameter being monitored is 'laserTemp' or +-- 'apdTemp', the supported range is from -10000 to 30000, in +-- 1/100ths of degrees centigrade. +-- Example: A value of 2355 represents a temperature reading of +-- 23.55 degrees C. +-- +-- When the optical parameter being monitored is 'biasCurrent', +-- the supported range is from 0 to 1000, in 1/10ths of +-- percentage (%). +-- Example: A value of 500 represents a bias current threshold +-- of 50.0 %. +-- +-- When the optical parameter being monitored is 'peltierCurrent', +-- the supported range is from 0 to 10000, in milliamperes. +-- +-- When the optical parameter being monitored is 'xcvrVoltage', +-- the supported range is from 0 to 100000, in 1/10ths of +-- millivolts. + +cerent454ThresholdCurrentValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current value of the counter which + measures the metric. This column will never be + implemented as the value of this object is already + accessible through IETF MIBs." + ::= { cerent454ThresholdEntry 60 } + +-- TEXTUAL CONVENTION +-- Description +-- The value of the optical parameter that is being monitored. +-- +-- The range of values varies depending on the type of optical +-- parameter being monitored, as identified by a corresponding +-- object with syntax OpticalParameterType. +-- +-- when the optical parameter being monitored is 'power' or +-- 'acpower', the supported range is from -1000 to 1000, in +-- 1/10ths of dBm. +-- Example: Actual power of -40 dbm is represented as -400. +-- Actual power level of +30 dBm is represented as 300. +-- +-- When the optical parameter being monitored is 'laserTemp' or +-- 'apdTemp', the supported range is from -10000 to 30000, in +-- 1/100ths of degrees centigrade. +-- Example: A value of 2355 represents a temperature reading of +-- 23.55 degrees C. +-- +-- When the optical parameter being monitored is 'biasCurrent', +-- the supported range is from 0 to 1000, in 1/10ths of +-- percentage (%). +-- Example: A value of 500 represents a bias current threshold +-- of 50.0 %. +-- +-- When the optical parameter being monitored is 'peltierCurrent', +-- the supported range is from 0 to 10000, in milliamperes. +-- +-- When the optical parameter being monitored is 'xcvrVoltage', +-- the supported range is from 0 to 100000, in 1/10ths of +-- millivolts. + + +cerent454ThresholdDetectType OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + none(10), + mon(20), + term(30) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object will be the detect type for the + threshold." + ::= { cerent454ThresholdEntry 70 } + + +-- All Cisco ONS 15454 Notifications definitions. + +cerent454Events OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Place holder for all notifications of Cisco ONS 15454" + ::= { cerent454Mib 30 } + +cerent454V2Events OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The sub-identifier has to be zero, as part + of the interoperability agreement between + SNMPv1 and SNMPv2 worlds." + ::= { cerent454Events 0 } + +-- --------------------------------------------- +-- All the Cisco ONS 15454 notifications definitions +-- --------------------------------------------- + +-- object and event groups + +alarmUnknown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "alarm unknown" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + + ::= { cerent454V2Events 1 } + +alarmCutoffIsInManualMode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "alarm cutoff is in manual mode" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 10 } + +failureDetectedExternalToTheNE + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmAdditionalInfo, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "failure detected External to the NE" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 20 } + +externalError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "external error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 30 } + +excessiveSwitching + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "excessive switching" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 40 } + +sdccTerminationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "SDCC Termination failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 50 } + +incomingFailureCondition + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "incoming failure condition" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 60 } + +alarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "alarm indication signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 70 } + +alarmIndicationSignalLine + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "alarm indication signal LINE" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 80 } + +alarmIndicationSignalPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "alarm indication signal Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 90 } + +alarmIndicationSignalVT + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "alarm indication signal VT" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 100 } + +apsChannelFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "APS Channel Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 110 } + +channelByteFailureAPS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel Byte failure APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 120 } + +channelProtectionSwitchingChannelMatchFailureAPS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel Protection Switching Channel Match failure APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 130 } + +channelAutomaticProtectionSwitchModeMismatchAPS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel Automatic Protection Switch Mode Mismatch APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 140 } + +farEndProtectionLineFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Far End Protection Line Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 150 } + +inconsistentAPSCode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Inconsistent APS code" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 160 } + +improperAPSCode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Improper APS code" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 170 } + +nodeIdMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Node Id Mismatch APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 180 } + +channelDefaultKAPS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel Default K APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 190 } + +connectionLoss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Connection loss APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 200 } + +bipolarViolation + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "bipolar Violation" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 210 } + +carrierLossOnTheLAN + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "carrier Loss on the LAN" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 220 } + +concatenationErrorSTS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "concatenation error STS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 230 } + +excessCollisionsOnTheLAN + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "excess collisions on the LAN" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 240 } + +facilityFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Facility Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 250 } + +farEndAIS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end AIS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 260 } + +farEndMultipleDS1LOSDetectedOnDS3 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end Multiple DS1 LOS detected on DS3" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 270 } + +farEndDS1EqptFailNonServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end DS1 eqpt fail non service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 280 } + +farEndDS1EqptFailServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end DS1 Eqpt fail service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 290 } + +farEndSingleDS1LOS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end Single DS1 LOS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 300 } + +farEndDS3EqptFailNonServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end DS3 Eqpt failure non service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 310 } + +farEndDS3EqptFailServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end DS3 Eqpt failure service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 320 } + +farEndCommonEquipmentFailureNonServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end common Eqpt failure non service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 330 } + +farEndIDLE + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end IDLE" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 340 } + +farEndLOS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end LOS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 350 } + +farEndLOF + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end LOF" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 360 } + +farEndBlockError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far End Block Error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 370 } + +ds3IdleCondition + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "idle Condition DS3" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 380 } + +lossOfFrame + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loss of Frame" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 390 } + +lossOfPointer + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loss of Pointer" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 400 } + +lossOfPointerPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loss of Pointer Path " + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 410 } + +lossOfPointerVT + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loss of Pointer VT" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 420 } + +lossOfSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loss of Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 430 } + +outOfFrame + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "out of Frame" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 440 } + +pathSelectorFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Path Selector Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 450 } + +remoteAlarmIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "remote Alarm Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 460 } + +remoteFailureIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "remote Failure Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 470 } + +remoteFailureIndicationLine + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "remote Failure Indication LINE" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 480 } + +remoteFailureIndicationPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "remote Failure Indication Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 490 } + +remoteFailureIndicationVT + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "remote Failure Indication VT" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 500 } + +signalDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "facility has passed BER Threshold for Signal Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 510 } + +severelyErroredFrame + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "severely Errored Frame" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 520 } + +signalFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "facility has passed BER threshold for Signal Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 530 } + +signalLabelMismatchFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "signal Label Mismatch Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 540 } + +payloadDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Payload Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 550 } + +payloadDefectIndicationPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Payload Defect Indication - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 560 } + +payloadLabelMismatchPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Payload Label Mismatch - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 570 } + +signalLabelMismatchFailurePayloadLabelMismatchVT + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "signal Label Mismatch Failure Payload Label Mismatch VT" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 580 } + +unequippedPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Unequipped - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 590 } + +signalLabelMismatchFailureUnequippedVT + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "signal Label Mismatch Failure Unequipped VT" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 600 } + +lossOfSynchronization + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Loss of Synchronization" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 610 } + +outOfSynchronization + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Out of Synchronization" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 620 } + +primarySynchronizationReferenceFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Primary Synchronization Reference Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 630 } + +secondarySynchronizationReferenceFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Secondary Synchronization Reference Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 640 } + +thirdSynchronizationReferenceFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Third Synchronization Reference Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 650 } + +fourthSynchronizationReferenceFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Fourth Synchronization Reference Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 660 } + +fifthSynchronizationReferenceFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Fifth Synchronization Reference Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 670 } + +sixthSynchronizationReferenceFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Sixth Synchronization Reference Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 680 } + +failedToReceiveSynchronizationStatusMessage + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "failed to receive Synchronization Status Message" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 690 } + +synchronizationStatusMessagesAreDisabledOnThisInterface + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "synchronization Status Messages are disabled on this +interface" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 700 } + +stratum1PrimaryReferenceSourceTraceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Stratum1 Primary Reference Source Traceable" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 710 } + +synchronizedTraceabilityUnknown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "synchronized Traceability Unknown" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 720 } + +stratum2Traceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "stratum 2 Traceable " + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 730 } + +transitNodeClockTraceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "transit Node clock Traceable" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 740 } + +stratum3ETraceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "stratum 3E Traceable" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 750 } + +stratum3Traceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "stratum 3 Traceable" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 760 } + +sonetMinimumClockTraceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "SONET Minimum Clock Traceable" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 770 } + +stratum4Traceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "stratum 4 Traceable" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 780 } + +doNotUseForSynchronization + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "do not Use for Synchronization" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 790 } + +reservedForNetworkSynchronizationUse + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "reserved for Network Synchronization Use" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 800 } + +outgoingFailureCondition + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "outgoing failure condition" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 810 } + +remoteDefectIndicationLine + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "remote Defect Indication LINE" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 820 } + +remoteDefectIndicationPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "remote Defect Indication Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 830 } + +freeRunningSynchronizationMode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "free Running Synchronization mode" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 840 } + +holdoverSynchronizationMode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "holdover synchronization mode" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 850 } + +fastStartSynchronizationMode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "fast Start synchronization mode" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 860 } + +internalFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Internal Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 870 } + +internalError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Internal Error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 880 } + +internalMessageError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "internal Message Error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 890 } + +mismatchOfEquipmentAndAttributes + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "mismatch of Equipment and Attributes" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 900 } + +watchdogTimerTimeout + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "watchdog Timer Timeout" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 910 } + +softwareFaultOrFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "software Fault or failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 920 } + +softwareFaultDataIntegrityFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "software Fault - Data integrity fault : + The newly added provisioning or hardware has + caused the database to grow beyond its limit. + That is, the newly added object(s) in the system + has(have) enough memory to exist onboard but + too large to be saved in the database." + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 930 } + +programFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "program failure " + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 940 } + +controlEquipmentFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "control Equipment failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 950 } + +primaryNonVolatileBackupMemoryFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Primary Non-Volatile Backup Memory Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 960 } + +secondaryNonVolatileBackupMemoryFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Secondary Non-Volatile Backup Memory Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 970 } + +controlBusFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Control Bus Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 980 } + +controlBus1Failure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Control Bus 1 Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 990 } + +controlBus2Failure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Control Bus 2 Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1000 } + +tccAToShelfSlot1DROP1CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 1 (DROP 1) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1010 } + +tccAToShelfSlot2DROP2CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 2 (DROP 2) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1020 } + +tccAToShelfSlot3DROP3CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 3 (DROP 3) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1030 } + +tccAToShelfSlot4DROP4CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 4 (DROP 4) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1040 } + +tccAToShelfSlot5TRUNK1CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 5 (TRUNK 1) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1050 } + +tccAToShelfSlot6TRUNK2CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 6 (TRUNK 2) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1060 } + +tccAToShelfSlot7TCCACommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 7 (TCC A) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1070 } + +tccAToShelfSlot8XCONACommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 8 (XCON A) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1080 } + +tccAToShelfSlot9AICCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 9 (AIC) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1090 } + +tccAToShelfSlot10XCONBCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 10 (XCON B) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1100 } + +tccAToShelfSlot11TCCBCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 11 (TCC B) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1110 } + +tccAToShelfSlot12TRUNK3CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 12 (TRUNK 3) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1120 } + +tccAToShelfSlot13TRUNK4CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 13 (TRUNK 4) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1130 } + +tccAToShelfSlot14DROP5CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 14 (DROP 5) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1140 } + +tccAToShelfSlot15DROP6CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 15 (DROP 6) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1150 } + +tccAToShelfSlot16DROP7CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 16 (DROP 7) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1160 } + +tccAToShelfSlot17DROP8CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC A To Shelf Slot 17 (DROP 8) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1170 } + +tccAToDCCAProcessorCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "communication failure TCC A to DCC A processor" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1180 } + +tccBToShelfSlot1DROP1CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 1 (DROP 1) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1190 } + +tccBToShelfSlot2DROP2CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 2 (DROP 2) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1200 } + +tccBToShelfSlot3DROP3CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 3 (DROP 3) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1210 } + +tccBToShelfSlot4DROP4CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 4 (DROP 4) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1220 } + +tccBToShelfSlot5TRUNK1CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 5 (TRUNK 1) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1230 } + +tccBToShelfSlot6TRUNK2CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 6 (TRUNK 2) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1240 } + +tccBToShelfSlot7TCCACommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 7 (TCC A) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1250 } + +tccBToShelfSlot8XCONACommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 8 (XCON A) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1260 } + +tccBToShelfSlot9AICCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 9 (AIC) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1270 } + +tccBToShelfSlot10XCONBCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 10 (XCON B) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1280 } + +tccBToShelfSlot11TCCBCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 11 (TCC B) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1290 } + +tccBToShelfSlot12TRUNK3CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 12 (TRUNK 3) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1300 } + +tccBToShelfSlot13TRUNK4CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 13 (TRUNK 4) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1310 } + +tccBToShelfSlot14DROP5CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 14 (DROP 5) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1320 } + +tccBToShelfSlot15DROP6CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 15 (DROP 6) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1330 } + +tccBToShelfSlot16DROP7CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 16 (DROP 7) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1340 } + +tccBToShelfSlot17DROP8CommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To Shelf Slot 17 (DROP 8) Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1350 } + +tccBToDCCBProcessorCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TCC B To DCC B Processor Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1360 } + +controlEquipmentControlCommunicationsEquipmentFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "control Equipment Control Communications equipment failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1370 } + +controlProcessorFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Control Processor Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1380 } + +workingMemoryFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Working Memory Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1390 } + +interconnectionEquipmentFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "interconnection Equipment failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1400 } + +payloadBusFailureToIOSlot1XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 1 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1410 } + +payloadBusFailureToIOSlot2XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 2 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1420 } + +payloadBusFailureToIOSlot3XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 3 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1430 } + +payloadBusFailureToIOSlot4XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 4 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1440 } + +payloadBusFailureToIOSlot5XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 5 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1450 } + +payloadBusFailureToIOSlot6XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 6 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1460 } + +payloadBusFailureToIOSlot12XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 12 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1470 } + +payloadBusFailureToIOSlot13XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 13 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1480 } + +payloadBusFailureToIOSlot14XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 14 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1490 } + +payloadBusFailureToIOSlot15XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 15 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1500 } + +payloadBusFailureToIOSlot16XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 16 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1510 } + +payloadBusFailureToIOSlot17XCONSlot8 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 17 (XCON Slot 8)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1520 } + +payloadBusFailureToIOSlot1XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 1 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1530 } + +payloadBusFailureToIOSlot2XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 2 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1540 } + +payloadBusFailureToIOSlot3XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 3 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1550 } + +payloadBusFailureToIOSlot4XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 4 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1560 } + +payloadBusFailureToIOSlot5XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 5 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1570 } + +payloadBusFailureToIOSlot6XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 6 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1580 } + +payloadBusFailureToIOSlot12XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 12 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1590 } + +payloadBusFailureToIOSlot13XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 13 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1600 } + +payloadBusFailureToIOSlot14XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 14 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1610 } + +payloadBusFailureToIOSlot15XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 15 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1620 } + +payloadBusFailureToIOSlot16XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 16 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1630 } + +payloadBusFailureToIOSlot17XCONSlot10 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Payload Bus Failure To IO Slot 17 (XCON Slot 10)" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1640 } + +timeSlotInterchangeEquipmentFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Time Slot Interchange Equipment Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1650 } + +equipmentFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "equipment failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1660 } + +highTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "High Temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1670 } + +invalidMACAddress + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Invalid MAC Address" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1680 } + +boardFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Board Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1690 } + +diagnosticFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "equipment failure Diagnostics Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1700 } + +mediumAccessControlFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Medium Access Control Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1710 } + +facilityTerminationEquipmentFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "facility Termination equipment failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1720 } + +automaticLaserShutoffDueToHighTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Automatic Laser Shutoff Due To High Temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1730 } + +failureToReleaseFromProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "failure To Release from protection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1740 } + +receiverFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Receiver Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1750 } + +transmitFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Transmit Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1760 } + +facilityTerminationEquipmentReceiverMissing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "facility Termination equipment Receiver missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1770 } + +facilityTerminationEquipmentTransmitterMissing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "facility Termination equipment Transmitter missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1780 } + +failureToSwitchToProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "failure To Switch to protection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1790 } + +failureToSwitchToProtectionRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "failure To Switch to protection Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1800 } + +failureToSwitchToProtectionSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "failure To Switch to protection Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1810 } + +failureToSwitchToProtectionPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "failure to Switch to protection Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1820 } + +fanFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Fan Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1830 } + +equipmentUnitPlugIn + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "equipment unit plug in" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1840 } + +nePowerFailureAtConnector + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "NE Power Failure At Connector" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1850 } + +fuseAlarm + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Fuse Alarm" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1860 } + +synchronizationUnitFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "synchronization unit failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1870 } + +synchronizationSwitchingEquipmentFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "synchronization switching Equipment failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1880 } + +equipmentUnitUnplugged + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Equipment Unit Un-plugged" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1890 } + +loopback + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loop back" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1900 } + +ds1LoopbackDueToFEACCommand + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "DS1 Loopback Due To FEAC Command" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1910 } + +loopbackCommandSentToFarEndDS1 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loopback Command sent to Far End DS1" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1920 } + +ds3LoopbackDueToFEACCommand + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loopback due to FEAC command DS3" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1930 } + +ds3LoopbackCommandSentToFarEnd + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "DS3 Loopback Command Sent To Far End" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1940 } + +ds2LoopbackDueToFarEndCommand + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "DS2 Loopback Due To Far End Command" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1950 } + +ds2LoopbackCommandSentToFarEnd + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "DS2 Loopback Command Sent To Far End" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1960 } + +facilityLoopback + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Facility Loopback" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1970 } + +networkLoopback + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Network Loopback" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1980 } + +terminalLoopback + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Terminal Loopback" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 1990 } + +manuallyCausedAbnormalCondition + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "manually caused abnormal condition" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2000 } + +ethernetBridgeIsNewRootOfSpanningTree + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ethernet Bridge Is New Root Of Spanning Tree" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2010 } + +ethernetBridgeTopologyChange + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ethernet Bridge Topology Change" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2020 } + +normalCondition + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "normal condition" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2030 } + +embeddedOperationsChannelFailureLinkDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "embedded Operations Channel failure link down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2040 } + +peerStateMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "peer state mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2050 } + +proceduralError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "procedural Error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2060 } + +improperRemoval + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Improper Removal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2070 } + +duplicateNodeID + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Duplicate Node ID" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2080 } + +blsrOutOfSync + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "BLSR out of sync" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2090 } + +blsrMultiNodeTableUpdateCompleted + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "BLSR Multi-Node Table Update Completed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2100 } + +protectionUnitNotAvailable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "protection unit not available" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2110 } + +performanceMonitorThresholdCrossingAlert + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454ThresholdMonitorType, + cerent454ThresholdLocation, + cerent454ThresholdPeriod, + cerent454ThresholdSetValue, + cerent454ThresholdCurrentValue, + cerent454ThresholdDetectType, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "performance Monitor Threshold Crossing Alert" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2120 } + +protectionSwitch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Protection Switch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2130 } + +recoveryOrServiceProtectionActionHasBeenInitiated + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "recovery or service protection action has been initiated" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2140 } + +automaticSystemReset + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "automatic system Reset" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2150 } + +automaticUPSRSwitchCausedByAIS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "automatic UPSR switch caused by AIS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2160 } + +automaticUPSRSwitchCausedByLOP + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "automatic UPSR switch caused by Lop" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2170 } + +automaticUPSRSwitchCausedByUNEQ + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Automatic UPSR Switch Caused By UNEQ" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2180 } + +automaticUPSRSwitchCausedByPDI + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "automatic UPSR switch caused by PDI" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2190 } + +automaticUPSRSwitchCausedBySFBER + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Automatic UPSR Switch Caused By SFBER" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2200 } + +automaticUPSRSwitchCausedBySDBER + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Automatic UPSR Switch Caused By SDBER" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2210 } + +coldRestart + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "cold Restart" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2220 } + +forcedSwitchBackToWorking + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch Back To Working" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2230 } + +forcedSwitchBackToWorkingRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch Back To Working - Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2240 } + +forcedSwitchBackToWorkingSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch Back To Working - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2250 } + +forcedSwitchToProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch To Protection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2260 } + +forcedSwitchToProtectionRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch To Protection - Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2270 } + +forcedSwitchToProtectionSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch To Protection - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2280 } + +workingFacilityOrEquipmentForcedToSwitchToProtectionPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Working Facility or Equipment Forced To Switch To Protection - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2290 } + +initializationInitiated + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "initialization initiated" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2300 } + +lockoutOfProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "lockout of Protection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2310 } + +lockoutOfProtectionRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "lockout of Protection Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2320 } + +lockoutOfProtectionSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "lockout of Protection Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2330 } + +lockoutOfProtectionPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "lockout of Protection Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2340 } + +lockoutOfWorking + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "lockout of working" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2350 } + +lockoutOfWorkingRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "lockout of working Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2360 } + +lockoutOfWorkingSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "lockout of working Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2370 } + +manualSystemReset + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "manual system Reset" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2380 } + +manualSwitchToInternalClock + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch to Internal Clock" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2390 } + +manualSwitchToPrimaryReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch To Primary Reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2400 } + +manualSwitchToSecondReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch To Second Reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2410 } + +manualSwitchToThirdReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch To Third reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2420 } + +manualSwitchToFourthReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch To Fourth reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2430 } + +manualSwitchToFifthReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch To Fifth reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2440 } + +manualSwitchToSixthReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch To Sixth reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2450 } + +manualSwitchBackToWorking + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Manual Switch Back To Working" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2460 } + +manualSwitchBackToWorkingRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Manual Switch Back To Working - Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2470 } + +manualSwitchBackToWorkingSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Manual Switch Back To Working - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2480 } + +manualSwitchToProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Manual Switch To Protection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2490 } + +manualSwitchToProtectionRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Manual Switch To Protection - Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2500 } + +manualSwitchToProtectionSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Manual Switch To Protection - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2510 } + +manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Manual Switch Of Working Facility or Equipment To Protection - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2520 } + +powerfailRestart + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Powerfail Restart" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2530 } + +ringIsSquelchingTraffic + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ring is squelching traffic" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2540 } + +softwareDownloadInProgress + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "software download in progress" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2550 } + +switchToInternalClock + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switch To Internal clock" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2560 } + +switchToPrimaryReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switch To Primary refernce" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2570 } + +switchToSecondReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Switch To Second Reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2580 } + +switchToThirdReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switch To Third refernce" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2590 } + +switchToFourthReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switch To Fourth refernce" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2600 } + +switchToFifthReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switch To Fifth refernce" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2610 } + +switchToSixthReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switch To Sixth refernce" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2620 } + +systemReboot + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "system reboot" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2630 } + +switchedBackToWorking + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switched Back To Working" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2640 } + +switchedToProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switched To Protection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2650 } + +warmRestart + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "warm Restart" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2660 } + +ringIsInWaitToRestoreState + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ring is in Wait To Restore state" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2670 } + +manualSwitchRequest + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch Request" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2680 } + +forcedSwitchRequest + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Forced Switch Request" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2690 } + +lockoutSwitchRequest + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Lockout Switch Request" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2700 } + +rmonHistoriesAndAlarmsResetReboot + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "RMON Histories And Alarms Reset Reboot" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2710 } + +rmonThresholdCrossingAlarm + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Crossing of Falling/Rising Threshold detected" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2720 } + +alarmsSuppressedByUserCommand + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Alarms Suppressed By User Command" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2730 } + +alarmsSuppressedForMaintenance + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Alarms Suppressed For Maintenance" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2740 } + +switchingMatrixModuleFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switching Matrix Module Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2750 } + +lanConnectionPolarityReversed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Lan Connection Polarity Reversed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2760 } + +autonomousPMReportMessageInhibited + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Autonomous PM Report Message Inhibited" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2780 } + +ioSlotToXCONCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "IO Slot To XCON Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2790 } + +stsPathTraceIdentifierMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "STS Path Trace Identifier Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2800 } + +nePowerFailureAtConnectorA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "NE Power Failure At Connector A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2810 } + +nePowerFailureAtConnectorB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "NE Power Failure At Connector B" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2820 } + +freeMemoryOnCardVeryLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Free memory on the card is very low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2830 } + +freeMemoryOnCardNearZero + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Free memory on the card is near zero" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2840 } + +exerciseRequestOnRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Exercise Request on Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2850 } + +exerciseRequestOnSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Exercise Request on Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2860 } + +squelchingPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Squelching Path" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2870 } + +extraTrafficPreempted + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Extra Traffic Preempted." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2880 } + +farEndLockoutOfWorkingRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End Lockout of working - Ring." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2890 } + +farEndLockoutOfWorkingSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End Lockout of working - Span." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2900 } + +farEndLockoutOfProtectionRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End Lockout of Protection - Ring." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2910 } + +farEndLockoutOfProtectionAllSpans + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End Lockout of Protection - All Spans." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2920 } + +farEndWorkingFacilityForcedToSwitchToProtectionRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Far End Working Facility Forced To Switch To Protection - Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2930 } + + +farEndWorkingFacilityForcedToSwitchToProtectionSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Far End Working Facility Forced To Switch To Protection - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2940 } + +farEndManualSwitchOfWorkingFacilityToProtectionRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Far End Manual Switch Of Working Facility To Protection - Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2950 } + +farEndManualSwitchOfWorkingFacilityToProtectionSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Far End Manual Switch Of Working Facility To Protection - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2960 } + +farEndExercisingRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Far End Exercising Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2970 } + +farEndExercisingSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Far End Exercising Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2980 } + +farEndBERThresholdPassedForSignalFailureRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End BER threshold passed for Signal Failure - Ring." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 2990 } + +farEndBERThresholdPassedForSignalFailureSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End BER threshold passed for Signal Failure - Span." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3000 } + +farEndBERThresholdPassedForSignalDegradeRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End BER threshold passed for Signal Degrade - Ring." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3010 } + +farEndBERThresholdPassedForSignalDegradeSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End BER threshold passed for Signal Degrade - Span." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3020 } + +apsChannelFarEndProtectionLineSignalDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "APS Channel - Far End Protection Line Signal Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3030 } + +ringSwitchIsActiveOnTheEastSide + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ring Switch is active on the East Side." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3040 } + + +ringSwitchIsActiveOnTheWestSide + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ring Switch is active on the West Side." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3050 } + +spanSwitchIsActiveOnTheEastSide + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Span Switch is active on the East Side." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3060 } + +spanSwitchIsActiveOnTheWestSide + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Span Switch is active on the West Side." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3070 } + +uniDirectionalFullPassThroughIsActive + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Uni-directional Full Pass Through is active." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3080 } + + +biDirectionalFullPassThroughIsActive + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Bi-directional Full Pass Through is active." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3090 } + +kBytesPassThroughIsActive + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "K Bytes Pass Through Is Active" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3100 } + +ringIsSegmented + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ring is Segmented." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3110 } + +ringTopologyIsUnderConstruction + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ring Topology is under construction." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3120 } + +lockoutOfProtectionAllSpans + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Lockout of Protection - All Spans." + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3130 } + +farEndOfFiberIsProvisionedWithDifferentRingID + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far end of fiber is provisioned with different ring ID" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3140 } + +bothEndsOfFiberProvisionedAsEastOrBothAsWest + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Both ends of fiber provisioned as East, or both as West" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3150 } + +securityInvalidLoginUsernameSeeAuditTrail + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS deprecated + DESCRIPTION "Security: invalid login (see Audit Trail)" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3160 } + +autonomousMessagesInhibited + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Autonomous messages inhibited" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3170 } + +trafficStormOnLANLANTemporarilyDisabled + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Traffic Storm On LAN. LAN Temporarily Disabled" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3180 } + +reptdbchgMessagesInhibited + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "REPT^DBCHG Messages Inhibited" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3190 } + +securityUserIDHasExpired + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Security: User ID Has Expired" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3200 } + +partialFanFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Partial Fan Failure" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3210 } + +forcedSwitchRequestOnRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch Request On Ring" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3220 } + +forcedSwitchRequestOnSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch Request On Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3230 } + +lockoutSwitchRequestOnRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Lockout switch request on Ring" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3240 } + +lockoutSwitchRequestOnSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Lockout switch request on Span" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3250 } + +manualSwitchRequestOnRing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual switch request on Ring" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3260 } + +manualSwitchRequestOnSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual switch request on Span" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3270 } + +communicationFailurePeerToPeerSlotControlBusA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Peer to Peer Slot communication failure - Control Bus A" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3280 } + +communicationFailurePeerToPeerSlotControlBusB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Peer to Peer Slot communication failure - Control Bus B" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3290 } + +controllerAToShelfSlotCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Controller A to shelf slot communication failure" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3300 } + +controllerBToShelfSlotCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Controller B to shelf slot communication failure" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3310 } + +interconnectionEquipmentFailureWorkingPayloadBus + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Interconnection Equipment Failure - Working Payload Bus" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3320 } + +interconnectionEquipmentFailureProtectPayloadBus + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Interconnection Equipment Failure - Protect Payload Bus" + + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3330 } + +inhibitSwitchToProtectRequestOnEquipment + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Inhibit Switch to Protect Request on equipment" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3340 } + +inhibitSwitchToWorkingRequestOnEquipment + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Inhibit Switch to Working Request on equipment" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3350 } + +berThresholdExceededForSignalDegradeLine + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "BER Threshold exceeded for Signal Degrade - Line" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3360 } + +berThresholdExceededForSignalDegradePath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "BER Threshold exceeded for Signal Degrade - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3370 } + +berThresholdExceededForSignalFailureLine + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "BER Threshold Exceeded For Signal Failure - Line" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3380 } + +berThresholdExceededForSignalFailurePath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "BER Threshold Exceeded For Signal Failure - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3390 } + +exercisingRingSuccessfully +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Exercising Ring Successfully" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3400} + +exercisingSpanSuccessfully +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Exercising Span Successfully" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3410} + +spanIsInWaitToRestoreState +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Span is in Wait To Restore state" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3420 } + +exerciseRequestOnRingFailed +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Exercise Request on Ring Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3430 } + +exerciseRequestOnSpanFailed +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Exercise Request on Span Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3440 } + +farEndLockoutOfProtectionSpan +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Far End Lockout Of Protection - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3450 } + +manufacturingDataMemoryEEPROMFailure +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Manufacturing Data Memory (EEPROM) Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3460 } + +replaceableEquipmentOrUnitIsMissing +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Replaceable Equipment/Unit is Missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3470 } + +softwareDownloadFailed +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Software Download Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3480 } + +extraTrafficPCADropped +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Extra Traffic (PCA) Dropped" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3490 } + +etherTxOversubscribed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ether tx oversubscribed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3500 } + +etherRxOverSubscribed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ether rx over subscribed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3510 } + +etherTxExcessFlowCtrl + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ether tx excess flow ctrl" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3520 } + +etherRxExcessFlowCtrl + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ether rx excess flow ctrl" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3530 } + +transportLayerFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "transport layer failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3540 } + +etherTxUnderrun + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ether tx underrun" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3550 } + +synchronizationReferenceFrequencyOutOfBounds + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Synchronization reference frequency out of bounds." + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3560 } + +ntpOrSntpHostFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "NTP/SNTP Host Failure." + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3570 } + +peerCardNotResponding +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Peer Card Not Responding" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3580 } + +alarmsAndEventsSuppressedForThisObject +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Alarms and events suppressed for this object" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3590 } + +ds3FrameFormatMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "DS3 Frame Format Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3600 } + +waitToRestore + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Wait To Restore" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3610 } + +extremeHighVoltBatteryA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Extreme High Volt Battery A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3620 } + +extremeLowVoltBatteryA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Extreme Low Volt Battery A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3630 } + +extremeHighVoltBatteryB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Extreme High Volt Battery B" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3640 } + +extremeLowVoltBatteryB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Extreme Low Volt Battery B" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3650 } + +iosConfigCopyFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "IOS config copy failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3660 } + +iosConfigCopyInProgress + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "IOS config copy in progress" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3670 } + +iosConfigCopySuccess + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "IOS Config Copy Success" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3680 } + +-- Begin: UCP traps + +signalingUnableToSetupCircuit +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Signaling Unable to setup circuit" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3710 } + +errorInStartupConfig + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Error in Startup Config" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3712 } + +noStartupConfig + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "No Startup Config" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3714 } + +needToSaveRunningConfig + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Need to Save Running Config" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3716 } + +invalidAlarm + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Invalid Alarm" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3718 } + +rsvpHelloFSMToNeighborDown +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "RSVP Hello FSM to Neighbor down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3720 } + +securityInvalidLoginUsername + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Security: Invalid Login - Username - See Audit Log" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3722 } + +databaseBackupFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Database Backup Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3724 } + +databaseRestoreFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Database Restore Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3726 } + +lmpHelloFSMToControlChannelDown +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LMP Hello FSM to Control Channel down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3730 } + +lmpNeighborDiscoveryHasFailed +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LMP Neighbor Discovery has failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3740 } + +unauthorizedIncomingSignalingRequest +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Unauthorized incoming signaling request" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3750 } + +auditLog80PercentFull + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Audit Log 80 Percent Full" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3760 } + +moduleCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Module Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3762 } + +auditLog100PercentFullOldestRecordsWillBeLost + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Audit Log 100 Percent Full - Oldest records will be lost" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3764 } + +standbyDatabaseOutOfSync + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Standby Database Out of Sync" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3766 } + +redundantPowerCapabilityLost + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Redundant Power Capability Lost" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3768 } + +-- End: UCP traps + +forcedSwitchToPrimaryReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Forced Switch To Primary Reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3770 } + +forcedSwitchToSecondReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Forced Switch To Second Reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3780 } + +forcedSwitchToThirdReference + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Forced Switch To Third Reference" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3790 } + +forcedSwitchToInternalClock + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Forced Switch To Internal Clock" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3800 } + +industrialHighTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Industrial High Temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 3805 } + + +-- Begin: SDH Traps + +timSectionTraceIdentifierMismatchFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "TIM Section - Trace Identifier Mismatch Failure." + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4000 } + +aisMultiplexSectionAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "AIS - Multiplex Section - Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4010 } + +rdiMultiplexSectionRemoteDefectOrAlarmIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "RDI - Multiplex Section - Remote Defect/Alarm Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4020 } + +timHighOrderTraceIdentifierMismatchFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TIM High Order - Trace Identifier Mismatch Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4030 } + +aisAdministrationUnitAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "AIS - Administration Unit - Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4040 } + +lopAdministrationUnitLossOfPointer + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LOP - Administration Unit - Loss of Pointer" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4050 } + +slmfUnequippedHighOrderPathUnequipped + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "SLMF - Unequipped High Order - Path Unequipped" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4060 } + +slmfPLMHighOrderPathLabelMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "SLMF - PLM High Order - Path Label Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4070 } + +rdiHighOrderRemoteDefectOrAlarmIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "RDI - High Order - Remote Defect/Alarm Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4080 } + +lopTributaryUnitLossOfPointer + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LOP - Tributary Unit - Loss of Pointer" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4090 } + +aisTributaryUnitAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "AIS - Tributary Unit - Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4100 } + +slmfUnequippedLowOrderPathUnequipped + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "SLMF - Unequipped Low Order - Path Unequipped" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4110 } + +slmfPLMLowOrderPathLabelMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "SLMF - PLM Low Order - Path Label Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4120 } + +timLowOrderTraceIdentifierMismatchFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "TIM Low Order - Trace Identifier Mismatch Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4130 } + +rfiLowOrderRemoteFailureOrAlarmIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "RFI - Low Order - Remote Failure/Alarm Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4140 } + +g811PrimaryReferenceClockTraceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "G811 - Primary Reference Clock traceable." + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4150 } + +g812TransitNodeClockTraceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "G812 - Transit Node Clock traceable." + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4160 } + +g812LocalNodeClockTraceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "G812 - Local Node Clock traceable." + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4170 } + +g813SynchronousEquipmentTimingSourceTraceable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "G813 - Synchronous Equipment Timing Source traceable" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4180 } + +e1LoopbackDueToFEACCommand + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "E1 loopback due to FEAC command" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4190 } + +e1LoopbackCommandSentToFarEnd + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "E1 loopback command sent to Far End" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4200 } + +e3LoopbackDueToFEACCommand + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "E3 loopback due to FEAC command" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4210 } + +farEndMultipleE1LOSDetectedOnE3 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end Multiple E1 LOS detected on E3" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4220 } + +farEndE1EqptFailNonServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end E1 eqpt fail non service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4230 } + +farEndE1EqptFailServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end E1 eqpt fail service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4240 } + +farEndSingleE1LOS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end Single E1 LOS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4250 } + +farEndE3EqptFailServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end E3 eqpt fail service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4260 } + +e3LoopbackCommandSentToFarEnd + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "E3 loopback command sent to far end" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4270 } + +farEndE3EqptFailNonServiceAffecting + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "far end E3 eqpt fail non service affecting" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4280 } + +lowVoltBatteryA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Low Volt - Battery A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4290 } + +highVoltBatteryA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "High Volt - Battery A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4300 } + +lowVoltBatteryB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Low Volt - Battery B" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4310 } + +highVoltBatteryB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "High Volt - Battery B" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4320 } + +msspRingOutOfSync +NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "MS-SP ring out of sync" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4330 } + +msspMultiNodeTableUpdateCompleted + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "MSSP Multi-Node Table Update Completed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4340 } + +automaticSNCPSwitchCausedByAIS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "automatic SNCP switch caused by AIS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4350 } + +automaticSNCPSwitchCausedByLOP + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "automatic SNCP switch caused by Lop" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4360 } + +automaticSNCPSwitchCausedByUNEQ + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Automatic SNCP Switch caused by UNEQ" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4370 } + +automaticSNCPSwitchCausedByPDI + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "automatic SNCP switch caused by PDI" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4380 } + +automaticSNCPSwitchCausedBySFBER + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Automatic SNCP Switch caused by SFBER" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4390 } + +automaticSNCPSwitchCausedBySDBER + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Automatic SNCP Switch caused by SDBER" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4400 } + +stmConcatenationError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "STM Concatenation error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4410 } + +e3IdleCondition + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "E3 Idle Condition" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4420 } + +channelMSSPInconsistentAPSCode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel MSSP inconsistent APS code" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4430 } + + +channelMSSPImproperAPSCodeAPS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel MSSP Improper APS code APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4440 } + +channelMSSPNodeIdMismatchAPS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel MSSP Node Id Mismatch APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4450 } + +channelMSSPDefaultKAPS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel MSSP Default K APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4460 } + +channelMSSPConnectionLossAPS + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "channel MSSP Connection loss APS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4470 } + +minimumClockTraceableSDH + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "SDH Minimum clock Traceable" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4480 } + +lineIsInWaitToRestoreStateSDH + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "SDH line is in Wait To Restore state " + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4490 } + +berThresholdExceededForSignalDegradeHighOrder + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "BER Threshold Exceeded For Signal Degrade - High Order" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4500 } + +berThresholdExceededForSignalFailureHighOrder + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "BER Threshold Exceeded For Signal Failure - High Order" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4510 } + +berThresholdExceededForSignalDegradeLowOrder + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "BER Threshold Exceeded For Signal Degrade - Low Order" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4520 } + +berThresholdExceededForSignalFailureLowOrder + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "BER Threshold Exceeded For Signal Failure - Low Order" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4530 } + +failureToSwitchToProtectionHighOrderPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Failure To Switch To Protection - High Order Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4540 } + +failureToSwitchToProtectionLowOrderPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Failure To Switch To Protection - Low Order Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4550 } + +lofAdministrationUnitLossOfMultiFrame + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LOF - Administration Unit - Loss of Multi Frame" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4560 } + +sdhSpanIsInWaitToRestoreState + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "SDH span is in Wait To Restore state" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4570 } + +-- End: SDH Traps + +a8b10bOutOfSync + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "8B10B Out of Sync" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4755 } + +odukPMAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "ODUk: PM Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4760 } + +otukAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OTUk: Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4765 } + +otukSMBackwardDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OTUk: Backward Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4770 } + +odukBackwardDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk: Backward Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4775 } + +fecUncorrectedWord + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "FEC Uncorrected Word" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4780 } + +gccTerminationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GCC Termination Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4785 } + +otukIncomingAlignmentError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OTUk: Incoming Alignment Error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4790 } + +odukLockedDefectPM + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "ODUk: Locked Defect - PM" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4795 } + +lossOfMultiFrame + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Loss of Multi-Frame" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4800 } + +odukOpenConnectionIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk: Open Connection Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4805 } + +payloadTypeIdentifierMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Payload Type Identifier Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4810 } + +odukTrailTraceIdentifierMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk: Trail Trace Identifier Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4815 } + +otukTrailTraceIdentifierMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OTUk: Trail Trace Identifier Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4820 } + +equipmentHighLaserBias + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment High Laser Bias" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4825 } + +equipmentHighLaserTemp + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment High Laser Temp" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4830 } + +equipmentHighLaserPeltier + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment High Laser Peltier" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4835 } + +facilityHighRxPower + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Facility High Rx power" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4840 } + +equipmentHighTxPower + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment High Tx power" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4845 } + +equipmentHighTransceiverVoltage + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment High Transceiver voltage" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4850 } + +equipmentLowLaserBias + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Low Laser Bias" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4855 } + +equipmentLowLaserTemp + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Low Laser Temp" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4860 } + +equipmentLowLaserPeltier + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Low Laser Peltier " + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4865 } + +facilityLowRxPower + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Facility Low Rx power" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4870 } + +equipmentLowTxPower + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Low Tx power" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4875 } + +equipmentLowTransceiverVoltage + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Low Transceiver voltage" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4880 } + +equipmentRxLocked + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Rx Locked" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4885 } + +equipmentSquelched + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Squelched" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4890 } + +equipmentTxLocked + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Tx Locked" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4895 } + +otukSignalFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OTUK Signal Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4900 } + +odukSignalFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUK Signal Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4905 } + +otukSignalDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OTUK Signal Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4910 } + +odukSignalDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUK Signal Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4915 } + +pluggablePortMissing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Pluggable Port missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4920 } + +pluggablePortRateMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Pluggable Port rate mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4925 } + +pluggablePortSecurityCodeMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Pluggable Port security code mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4930 } + +tciNotSelected + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Tci not selected" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4935 } + +tci1ClockFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Tci 1 Clock Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4940 } + +odukPMBackwardDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk: PM Backward Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4945 } + +odukTCM1BackwardDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk: TCM1 Backward Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4950 } + +odukTCM2BackwardDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk: TCM2 Backward Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4955 } + +equipmentHighRxTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment High Rx temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4960 } + +equipmentLowRxTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Low Rx temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4965 } + +tci2ClockFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Tci 2 Clock Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4970 } + +equipmentWavelengthMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Wavelength Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4975 } + +dspCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "DSP Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4980 } + +dspFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "DSP Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 4985 } + + +laserApproachingEndOfLife + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Laser Approaching End of Life" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5000 } + +crossconnectLoopback + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Cross-connect Loopback" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5010 } + +adminLogoutOfUser + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Admin Logout of User" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5020 } + +userLockedOut + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "User Locked Out" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5030 } + +adminLockoutOfUser + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Admin Lockout of User" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5040 } + +adminLockoutClear + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Admin Lockout Clear" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5050 } + +invalidLoginUsername + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Invalid Login: Username" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5060 } + +securityInvalidLoginPassword + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Security: Invalid Login - Password - See Audit Log" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5070 } + +securityInvalidLoginLockedOut + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Security: Invalid Login - Locked Out - See Audit Log" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5080 } + +securityInvalidLoginAlreadyLoggedOn + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Security: Invalid Login - Already Logged On - See Audit Log" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5090 } + +loginOfUser + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Login of User" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5100 } + +automaticLogoutOfIdleUser + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Automatic Logout of IdleUser" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5110 } + +logoutOfUser + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Logout of User" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5120 } + +enhancedRemoteFailureIndicationPathServer + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Enhanced Remote Failure Indication - Path - Server" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5200 } + + +enhancedRemoteFailureIndicationPathConnectivity + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Enhanced Remote Failure Indication - Path - Connectivity" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5210 } + +enhancedRemoteFailureIndicationPathPayload + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Enhanced Remote Failure Indication - Path - Payload" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5220 } + +firewallHasBeenDisabled + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Firewall Has Been Disabled" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5230 } + +securityIntrusionDetPwd + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Security Intrusion Attempt Detected - See Audit Log" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5240 } + +securityIntrusionDetUser + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Security Intrusion Attempt Detected - See Audit Log" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5250 } +connectionEquipmentMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Connection Equipment Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5260 } + +disableInactiveUser + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Disable Inactive User" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5270 } + +disableInactiveClear + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Disable Inactive Clear" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5280 } + + +batteryFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Battery Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5290 } + +extremeHighVolt + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Extreme High Volt" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5300 } + +extremeLowVolt + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Extreme Low Volt" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5310 } + +highVolt + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "High Volt" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5320 } + +lowVolt + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Low Volt" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5330 } + +suspendUser + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Suspend User" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5340 } + +suspendUserClear + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Suspend User Clear" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5350 } + + +lineDccTerminationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Line DCC Termination Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5360 } + +multiplexSectionDccTerminationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Multiplex Section DCC Termination Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5370 } + +gigaBitEthernetOutOfSync + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "GigaBit Ethernet Out of Sync" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5380 } + +sequenceMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Sequence Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5390 } + +lossOfAlignment + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Loss of Alignment" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5400 } + +outOfUseByAdministrativeCommand + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Out of Use - Administrative Command" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5410 } + +outOfUseTransportFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Out of Use - Transport Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5420 } + +vcatGroupDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "VCAT Group Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5430 } + +vcatGroupDegraded + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "VCAT Group Degraded" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5440 } + +vcatGroupIncomplete + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "VCAT Group Incomplete" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5450 } + +alarmIndicationSignalInTX + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Alarm Indication Signal in TX" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5460 } + +remoteAlarmIndicationInTX + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Remote Alarm Indication in TX" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5470 } + +kByteAPSChannelFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Kbyte Channel Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5480 } + +apsInvalidMode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "APS Invalid Mode" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5490 } + +ipAddressAlreadyInUseWithinTheSameDccArea + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "IP Address A1ready In Use Within The Same DCC Area" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5500 } + +nodeNameInUseWithinTheSameDccArea + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Node name already in use within the same DCC Area" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5510 } + +rearPanelEthernetLinkRemoved + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Rear Panel Ethernet Link Removed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5520 } + +manualSwitchToProtectResultedInNoTrafficSwitch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch To Protect Resulted in No Traffic Switch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5530 } + +manualSwitchBackToWorkingResultedInNoTrafficSwitch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Manual Switch Back To Working Resulted in No Traffic Switch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5540 } + +forcedSwitchToProtectResultedInNoTrafficSwitch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Forced Switch To Protection Resulted in No Traffic Switch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5550 } + +forcedSwitchBackToWorkingResultedInNoTrafficSwitch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Forced Switch Back To Working Resulted in No Traffic Switch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5560 } + +duplicateSerialNumberDetectedOnAPluggableEntity + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Duplicate Serial number detected on a pluggable entity" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5570 } + +lossOfSignalForOpticalChannel + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Incoming Payload Signal Absent" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5600 } + +encapsulationMismatchPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Encapsulation Mismatch Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5610 } + +encapsulationMismatchVT + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Encapsulation Mismatch - VT" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5620 } + +encapsulationMismatchHighOrderPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Encapsulation Mismatch High Order - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5630 } + +encapsulationMismatchLowOrderPath + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Encapsulation Mismatch Low Order - Path" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5640 } + +gfpUserPayloadMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GFP User Payload Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5650 } + +gfpFibreChannelDistanceExtensionMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GFP Fibre Channel Distance Extension Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5660 } + +gfpFibreChannelDistanceExtensionBufferStarvation + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GFP Fibre Channel Distance Extension Buffer Starvation" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5670 } + +gfpFibreChannelDistanceExtensionCreditStarvation + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Fibre Channel Distance Extension Credit Starvation" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5680 } + +automaticWdmAnsFinished + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Automatic WDM ANS Finished" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5690 } + +gfpClientSignalFailDetected + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GFP Client Signal Fail Detected" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5700 } + +gfpLossOfFrameDelineation + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GFP Loss of Frame Delineation" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5710 } + +gfpExtensionHeaderMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GFP Extension Header Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5730 } + +incomingOverheadSignalAbsent + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Incoming Overhead Signal Absent" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5740 } + +opticalSafetyRemoteInterlockOn + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Safety Remote Interlock On" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5750 } + +automaticPowerControlCorrectionSkipped + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Automatic Power Control Correction Skipped" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5770 } + +apcCannotSetValueDueToRangeLimits + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "APC cannot set value due to range limits" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5780 } + +lcasVcgMemberTxSideInAddState + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LCAS VCG Member Tx Side In ADD State" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5790 } + +farEndManualSwitchBackToWorkingSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End Manual Switch Back to Working - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5800 } + +farEndForcedSwitchBackToWorkingSpan + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Far End Forced Switch Back to Working - Span" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5810 } + +universalTransponderModuleHardwareFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Universal Transponder Module Hardware Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5820 } + +universalTransponderModuleCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Universal Transponder Module Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5830 } + +pluginModuleRangeSettingsMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Plug-in Module Range Settings Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5840 } + +lcasVcgMemberTxSideInDnuState + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LCAS VCG Member Tx Side In DNU State" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5850 } + +lcasControlWordCrcCheckFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LCAS Control Word CRC Check Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5860 } + +lcasVcgMemberRxSideInFailState + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "LCAS VCG Member Rx Side In FAIL State" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5870 } + +signalLossOnDataInterface + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Signal Loss on Data Interface" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5880 } + +synchronizationLossOnDataInterface + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Synchronization Loss on Data Interface" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5890 } + +portFAIL + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "PORT FAIL" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5900 } + +unreachablePortTargetPower + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Unreachable port target power" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5910 } + +portAddPowerDegradeLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Port Add Power Degrade Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5920 } + +portAddPowerDegradeHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Port Add Power Degrade High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5930 } + +portAddPowerFailLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Port Add Power Fail Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5940 } + +portAddPowerFailHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Port Add Power Fail High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 5950 } + +automaticPowerControlTerminatedOnManualRequest + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Automatic Power Control Terminated on Manual request" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6000 } + +oduk1AlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk-1: Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6010 } + +oduk2AlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk-2: Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6020 } + +oduk3AlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk-3: Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6030 } + +oduk4AlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk-4: Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6040 } + +temperatureReadingMismatchBetweenSCCards + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Temperature Reading Mismatch Between SC Cards" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6050 } + +voltageReadingMismatchBetweenSCCards + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Voltage Reading Mismatch Between SC Cards" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6060 } + +alarmsSuppressedonOutOfGroupVcatMember + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Alarms Suppressed on Out-Of-Group VCAT Member" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6070 } + +blsrSoftwareVersionMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "BLSR Software Version Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6080 } + +optimized1Plus1ApsPrimaryFacility + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Optimized 1+1 APS Primary Facility" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6090 } + +optimized1Plus1ApsPrimarySectionMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Optimized 1+1 APS Primary Section Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6100 } + +optimized1Plus1ApsInvalidPrimarySection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Optimized 1+1 APS Invalid Primary Section" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6110 } + +compositeClockHighLineVoltage + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Composite Clock High Line Voltage" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6120 } + +berThresholdExceededForSignalDegradeVt + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "BER Threshold Exceeded For Signal Degrade - VT" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6130 } + +berThresholdExceededForSignalFailureVt + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "BER Threshold Exceeded For Signal Failure - VT" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6140 } + +spanLengthOutOfRange + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Span Length Out of Range" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6150 } + +idleSignalCondition + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Idle Signal Condition" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6170 } + +idleSignalConditionInTx + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Idle Signal Condition in TX" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6180 } + +vtPathTraceIdentifierMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "VT Path Trace Identifier Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6190 } + +lossOfFrameInTX + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Loss of Frame in TX" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6200 } + +provisioningMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Provisioning Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6210 } + +sectionTraceIdentifierMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Section Trace Identifier Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6220 } + +regeneratorSectionTraceIdentifierMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Regenerator Section Trace Identifier Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6230 } + +switchingMatrixModuleFailureWorking + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switching Matrix Module Failure - Working" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6240 } + +switchingMatrixModuleFailureProtect + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Switching Matrix Module Failure - Protect" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6250 } + +slotCommunicationDisabled + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Slot Communication Disabled" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6260 } + +sessionTimeLimitExpired + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Session Time Limit Expired" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6270 } + +userPasswordChangeRequired + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "User Password Change Required" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6280 } + +isisAdjacencyFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ISIS Adjacency Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6290 } + +msspSoftwareVersionMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "MSSP Software Version Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6300 } + +remoteAuthenticationFailSeeAuditLog + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Remote Authentication Fail - See Audit Log" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6310 } + +ringIsSquelchingStsTraffic + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ring Is Squelching STS Traffic" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6330 } + +ringIsSquelchingVtTraffic + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ring Is Squelching VT Traffic" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6340 } + +archiveOfAuditLogFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Archival of Audit Log Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6350 } + +rprWrapped + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "RPR Wrapped" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6360 } + +shelfCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Shelf Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6370 } + +duplicatedShelfIdentifier + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Duplicated Shelf Identifier" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6380 } + +softwareMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Software Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6390 } + +lmpFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "LMP Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6400 } + +opticalTerminationIncomplete + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Termination Incomplete" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6410 } + +forwardDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Forward Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6420 } + +payloadMissingIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Payload Missing Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6430 } + +spanMeasurementCannotBePerformed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Span loss not checked" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6440 } + +ringIsSquelchingHighOrderTraffic + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ring Is Squelching High Order Traffic" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6450 } + +ringIsSquelchingLowOrderTraffic + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Ring Is Squelching Low Order Traffic" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6460 } + +badPacketCountExceedsThreshold + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Bad Packet Count Exceeds Threshold" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6470 } + +linkLayerKeepAliveFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Link Layer Keep-Alive Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6480 } + +autonegotiationRemoteFailureIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Auto-Negotiation Remote Failure Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6490 } + +trailSignalFail + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Trail Signal Fail" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6500 } + +ds1LoopbackCommandSentToFarEnd + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "DS1 Loopback Command Sent To Far End" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6510 } + +multiplexSectionSignalDegraded + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Multiplex Section - Signal Degraded" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6520 } + +multiplexSectionExcessiveErrors + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Multiplex Section - Excessive Errors" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6530 } + +highOrderPathSignalDegraded + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "High Order Path - Signal Degraded" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6540 } + +highOrderPathExcessiveErrors + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "High Order Path - Excessive Errors" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6550 } + +lowOrderPathSignalDegraded + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Low Order Path - Signal Degraded" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6560 } + +lowOrderPathExcessiveErrors + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Low Order Path - Excessive Errors" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6570 } + +regeneratorSectionDccTerminationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Regenerator Section - DCC Termination Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6580 } + +networkMemoryPoolLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Network Memory Pool Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6590 } + +ospfRoutingTableOverflow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OSPF Routing Table Overflow" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6600 } + +autoLaserShutdownDisabled + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Auto Laser Shutdown Disabled" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6610 } + +rprProtectionIsActive + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "RPR Protection Is Active" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6630 } + +maxRPRStationNumberExceeded + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Max RPR Station Number Exceeded" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6640 } + +rprProtectionConfigurationMismatched + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "RPR Protection Configuration Mismatched" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6650 } + +reservedBandwidthLinkRateExceededOnRinglet0 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Reserved Bandwidth Link Rate Exceeded On Ringlet0" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6660 } + +reservedBandwidthLinkRateExceededOnRinglet1 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Reserved Bandwidth Link Rate Exceeded On Ringlet1" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6670 } + +rprInterfaceInPassThroughMode + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "RPR Interface In Pass Through Mode" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6680 } + +rprPeerNodeIsMissing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "RPR Peer Node is Missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6690 } + +rprRiFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "RPR RI Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6700 } + +rprSignalFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "RPR Signal Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6710 } + +rprSignalDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "RPR Signal Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6720 } + +interlinkFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ADM Peer Cards Interlink Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6730 } + +apcWrongGain + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "APC Wrong Gain Set Point" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6740 } + +rprSpanMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "RPR Span Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6750 } + +efmRemoteFaultIndicationCriticalEvent + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Remote Fault Inidication- Critical Event" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6760 } + +efmRemoteFaultIndicationDyingGasp + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Remote Fault Inidication- Dying Gasp" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6770 } + +efmRemoteFaultIndicationLinkFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Remote Fault Inidication- Link Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6780 } + +efmLinkMonitoringErroredSymbolPeriodEvent + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Link Monitoring- Errored Symbol Period Event" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6790 } + +efmLinkMonitoringErroredFrameEvent + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Link Monitoring- Errored Frame Event" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6800 } + +efmLinkMonitoringErroredFramePeriodEvent + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Link Monitoring- Errored Frame Period Event" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6810 } + +efmLinkMonitoringErroredFrameSecondsSummary + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Link Monitoring- Errored Frame Seconds Summary" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6820 } + +efmRemoteLoopbackRequestFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Remote Loopback Request Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6830 } + +fastAutomaticProtectionSwitching + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Fast Automatic Protection Switching" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6840 } + +fastAutomaticProtectionSwitchingConfigMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Fast Automatic Protection Switching Config Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6850 } + +lcasSinkGroupError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "LCAS Sink Group Error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6860 } + +lcasVcgMemberRxSideInDnuState + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "LCAS VCG Member Rx Side In DNU State" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6870 } + +fcDistanceExtFuncNotEstablished + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION " Fibre Channel Distance Extension Function Not Established" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6880 } + +nonCiscoPPMInserted + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Non Cisco PPM Inserted" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6890 } + +unqualifiedPPMInserted + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Unqualified PPM Inserted" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6900 } + +ftaMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "FanTray Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6910 } + +cardPortsUnableToProvideProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Card/Ports Unable To Provide Protection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6920 } + +lmpSignalDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "LMP Signal Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6930 } + +lmpSignalFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "LMP Signal Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6940 } + +lmpUnallocatedDataLink + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "LMP Unallocated Data Link" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6950 } + +frontPortLinkLoss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "TCC Front Port Link Loss" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6960 } + +bertEnbl + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "BERT Enabled " + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6970 } + +bertSyncFail + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "BERT Synchronization Status Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6975 } + +workQueueFull + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Work Queue Full" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 6980 } + +equipmentPowerFailureAtConnectorA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment power failure at connector A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7000 } + +equipmentPowerFailureAtConnectorB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment power failure at connector B" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7005 } + +equipmentPowerFailureAtReturnConnectorA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment power failure at return connector A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7010 } + +equipmentPowerFailureAtReturnConnectorB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment power failure at return connector B" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7015 } + +bridgeAndRollHasOccurred + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Bridge and Roll Has Occurred" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7055 } + +bridgeAndRollIsPendingAValidSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Bridge and Roll is Pending a Valid Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7060 } + +clockBusFailureTscA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Clock Bus Failure - Shelf Controller A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7160 } + +clockBusFailureTscB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Clock Bus Failure - Shelf Controller B" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7165 } + +ospfHelloFail + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OSPF Hello Fail" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7185 } + +openIOSlots + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Open IO Slots" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7200 } + +lossOfClockFromMateShelfController + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Loss of Clock from Mate Shelf Controller" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7210 } + +virtualLanAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Virtual Lan AIS" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7225 } + +dcuLossFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "DCU Loss Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7230 } + +ochncMaintenance + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OCHNC Maintenance" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7235 } + +ramanLaserShutdown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Raman Laser Shutdown" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7240 } + +losOfRamanSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Loss Of Raman Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7245 } + +mcastMacTableFull + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Multicast Mac Address Table Full" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7250 } + +multicastMacAddressAliasing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Multicast Mac Address Aliasing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7255 } + +ramanPwrProtOn + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Raman Power Protection On" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7260 } + +cppPeerNotResponding + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "CPP Peer Not Responding" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7265 } + +voaControlLoopDisableDueToExcessiveCounterPropagationLight + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "VOA Control Loop Disable Due To Excessive Counter-Propagation Light" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7275 } + +wizardIsRunning + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Wizard Is Running" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7280 } + +ramanGainNotReached + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Raman Span Not Tuned" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7285 } + + +pprForwardDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "pprForwardDefectIndication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7295 } + +pprBackwardDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "pprBackwardDefectIndication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7300 } + +pprCoordinatedMaintenance + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "pprCoordinatedMaintenance" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7305 } + +pprTriggerThresholdBERExceeded + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "pprTriggerThresholdBERExceeded" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7310 } + +localFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Local Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7315 } + +remoteFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Remote Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7320 } + +efmRemoteLoopbackConfigured + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Port In Remote Loopback" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7325 } + +efmPeerMissing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "EFM Link To Peer Missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7330 } + +eqptDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Equipment Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7335 } + +excessiveBackPropagation + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Excessive Back Propagation" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7340 } + +remoteMaintenanceEndPointIsDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "CFM Remote Maintenance End Point Is Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7345 } + +crossConnectedCFMService + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Cross Connected CFM Service" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7350 } + +cfmLoop + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "CFM Loop" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7355 } + +cfmConfigurationError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "CFM Configuration Error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7360 } + +outOfChannelGroupBundle + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Out Of Channel Group Bundle" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7365 } + +repNeighborAdjacencyFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "REP Neighbor Adjacency Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7370 } + +repLinkFlapping + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "REP Link Flapping" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7375 } + +faultInREPSegment + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Fault In REP Segment" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7380 } + +primaryREPEdgePortElected + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Primary REP Edge Port Elected" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7385 } + +secondaryREPEdgePortElected + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Secondary REP Edge Port Elected" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7390 } + +stcnREPGenerated + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "STCN REP Generated" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7395 } + +vlbREPActivated + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "VLB REP Activated" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7400 } + +vlbREPTriggerSoakingDelayActive + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "VLB REP Trigger Soaking Delay Active" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7405 } + + +wanSyncloss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ethernet Syncloss On WAN Port" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7410 } + +laserShutdownDueToWavelengthDrift + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "laser Shutdown Due To Wavelength Drift" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7415 } + +manualLaserRestart + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "manual Laser Restart" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7420 } + +laserShutdownDueToNonCiscoPPMInserted + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "laserShutdownDueToNonCiscoPPMInserted" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7425 } + +ethernetOSCTerminationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ethernet OSC Termination Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7430 } + +softwareSignatureVerificationFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "software Signature Verification Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7445 } + +protectVolumeSoftwareSignatureVerificationFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Volume Software Signature Verification" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7450 } + +activeVolumeSoftwareSignatureVerificationFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Active Software Signature Verification Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7455 } + +peerPortClientSignalFailDetected + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Peer Port Client Signal Fail Detected" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7460 } + +channelShutdownDueToWavelengthDrift + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Channel Shutdown Due to Wavelength Drift" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7465 } + +usbWriteFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "USB Write Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7475 } + +usbSyncInProgress + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "USB Sync in Progress" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7480 } + +autoSensingUnableToDetectValidPayload + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Auto-Sensing Unable To Detect Valid Payload" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7485 } + +payloadAutoSensingInProgress + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Payload Auto-Sensing In Progress" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7490 } + +gfpClientSignalFailDetectedDueToSigloss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GFP Client Signal Fail Detected Due To Sigloss" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7495 } + +gfpClientSignalFailDetectedDueToSyncloss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "GFP Client Signal Fail Detected Due To Syncloss" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7500 } + +pmdDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "PMD Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7510 } + +standbyTccNEClockIsInternalClock + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Standby Tcc NE Clock Is Internal Clock" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7515 } + +chromaticDispersionValue + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "chromatic Dispersion Value" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7520 } + +packetTransportServiceFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Packet Transport Service Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7525 } + +satellitePanelDiscoveryFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Discovery Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7530 } + +satellitePanelActiveLinkFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Active Link Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7535 } + +satellitePanelCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7540 } + +satellitePanelImproperConfiguration + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Improper Configuration" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7545 } + +satellitePanelFanMismatchOfEquipmentAndAttributes + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Fan Mismatch Of Equipment And Attributes" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7550 } + +satellitePanelFanFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Fan Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7555 } + +satellitePanelPartialFanFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Partial Fan Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7560 } + +satellitePanelFANManufacturingDataMemoryEEPROMFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel FAN Manufacturing Data Memory (EEPROM) Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7565 } + +satellitePanelFANUnitIsMissing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel FAN Unit Is Missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7570 } + +satellitePanelIndustrialHighTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Industrial High Temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7575 } + +satellitePanelHighTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel High Temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7580 } + +satellitePanelBatteryFailureA + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Satellite Panel Battery Failure A" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7585 } + +plannedSwitchOver + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Planned Switch Over" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7590 } + +protectionCardConfigurationMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "protection CardConfiguration Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7595 } + +routerProcessorSwitchOver + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Router Processor Switch Over" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7600 } + +runningLowOnResources + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Running Low On Resources" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7605 } + +noMoreResourcesAreAvailable + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "No More Resources Are Available" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7610 } + +esmcFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ESMC Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7615 } + +licenseWillExpireWithin24Hours + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "License Will Expire Within 24 Hours" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7620 } + +licenseWillExpireAnytimeAfter1DayButBefore14Days + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "license Will Expire Anytime After 1Day But Before 14Days" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7625 } + +licenseIsExpired + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "license Is Expired" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7630 } + +licenseCountViolation + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "license Count Violation" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7635 } + +temporaryLicenseIsInUse + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Temporary License Is In Use" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7640 } + +evaluationLicenseIsInUse + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Evaluation License Is In Use" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7645 } + +licenseIsMissing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "License Is Missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7650 } + +pseudowireDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Pseudowire Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7655 } + +workingPseudowireControlPlaneDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Pseudowire Control Plane Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7660 } + +protectPseudowireControlPlaneDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Pseudowire Control Plane Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7665 } + +workingPseudowireConnectivityCheckDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Pseudowire Connectivity Check Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7670 } + +protectPseudowireConnectivityCheckDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Pseudowire Connectivity Check Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7675 } + +pseudowireTrafficSwitchedToProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Pseudowire Traffic Switched To Pretection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7680 } + +workingPseudowireLocalAcTxPortFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Pseudowire Local AcTx Port Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7685 } + +protectPseudowireLocalAcTxPortFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Pseudowire Local AcTx Port Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7690 } + +workingPseudowireLocalAcRxPortFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Pseudowire Local AcRx Port Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7695 } + +protectPseudowireLocalAcRxPortFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Pseudowire Local AcRx Port Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7700 } + +workingPseudowireRemoteAcTxPortFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Pseudowire Remote AcTx Port Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7705 } + +protectPseudowireRemoteAcTxPortFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Pseudowire Remote AcTx Port Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7710 } + +workingPseudowireRemoteAcRxPortFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "working Pseudowire Remote AcRx Port Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7715 } + +protectPseudowireRemoteAcRxPortFault + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Pseudowire Remote AcRx Port Fault" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7720 } + +slaThresholdCrossAlert + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "SLA Threshold Cross Alert" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7725 } + +protectLocalPseudowireNotForwarding + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Local Pseudowire Not Forwarding" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7730 } + +workingPseudowireNotForwarding + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Remote Pseudowire Not Forwarding" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7735 } + +protectPseudowireNotForwarding + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Remote Pseudowire Not Forwarding" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7740 } + +tpTunnelDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Tp Tunnel Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7745 } + +workingLabelSwitchedPathDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Label Switched Path Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7750 } + +protectLabelSwitchedPathDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Label Switched Path Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7755 } + +workingLabelSwitchedPathAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Label Switched Path Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7760 } + +protectLabelSwitchedPathAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Label Switched Path Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7765 } + +workingLabelSwitchedPathRemoteDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Label Switched Path Remote Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7770 } + +protectLabelSwitchedPathRemoteDefectIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Label Switched Path Remote Defect Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7775 } + +bidirectionalForwardDetectionDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Bidirectional Forward Detection Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7780 } + +tpTrafficSwitchedFromWorkingToProtection + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Tp Traffic Switched From Working To Protection" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7785 } + +workingTpLockout + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "working Tp Lockout" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7790 } + +protectTpLockout + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "protect Tp Lockout" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7795 } + + +ethernetFlowPointFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ethernet Flow Point Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7800 } + +teTunnelDown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "TE Tunnel Down" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7805 } + +macSystemLimitReached + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "MAC System Limit Reached" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7810 } + +macBridgeDomainLimitReached + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "MAC Bridge Domain Limit Reached" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7815 } + +autoSensingDisabled + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Auto Sense Disabled" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7820 } + +smBackwardIncomingAlignmentError + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "SM Backward Incoming Alignment Error" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7825 } + +resourceAllocationFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Resource Allocation Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7830 } + +lossOfDFBSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "loss Of DFB Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7835 } + + +workingLabelSwitchedPathLinkDownIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Label Switched Path Link Down Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7840 } + +protectLabelSwitchedPathLinkDownIndication + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Label Switched Path Link Down Indication" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7845 } + +workingLabelSwitchedPathLockReport + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Working Label Switched Path Lock Report" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7850 } + +protectLabelSwitchedPathLockReport + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Protect Label Switched Path Lock Report" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7855 } + +satellitePanelBatteryFailureB + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "satellite Panel Battery FailureB" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7860 } + +highBitErrorRate + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "High Bit Error Rate" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7865 } + +backPanelFacilityLoopback + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Back Panel Facility Loopback" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7870 } + +backPanelTerminalLoopback + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Back Panel Terminal Loopback" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7875 } + +trunkPayloadTypeMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Payload Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7880 } + +invalidMuxponderConfiguration + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Invalid Muxponder Configuration" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7885 } + +coolingProfileMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Cooling Profile Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7890 } + +trunkOduAlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Trunk ODU: Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7895 } + +companionCardMissing + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Companion Card Missing" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7900 } + +controlPlaneUnverifiedClearedAlarmsPresent + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Control Plane Unverified Cleared Alarms Present" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7905 } + +powerConsumptionLimitHasCrossed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Power Consumption Limit Has Crossed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7910 } + +masterKeyExchangeFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Master Key Exchange Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7915 } + +unitHighTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Unit High Temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7930 } + +overTemperatureUnitProtected + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Over Temperature Unit Protected" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7935 } + +seqMismatchCount + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Sequence Mismatch Count" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7945 } + +keyProgramOnAlteraFpgaFailed + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Key Program On Altera FPGA Failed" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7960 } + +duplicateNodeControllerDetected + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Duplicate Node Controller Detected" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7970 } + +restorationInProg + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Restoration in Progress" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7975 } + +ramanPumpsCalibrationProcedureIsRunning + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Raman Calibration Running" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7980 } + +ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Raman Calibration Pending" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 7985 } + +odukTCM1AlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "ODUk: TCM1 Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13100 } + +odukTCM2AlarmIndicationSignal + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "ODUk: TCM2 Alarm Indication Signal" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13105 } + +odukLockedDefectTCM1 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Locked Defect - TCM1" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13110 } + +odukLockedDefectTCM2 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Locked Defect - TCM2" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13115 } + +otukLossOfFrame + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "OTUk: Loss Of Frame" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13120 } + +odukOpenConnectionIndicationTCM1 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Open Connection Indication TCM1" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13125 } + +odukOpenConnectionIndicationTCM2 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Open Connection Indication TCM2" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13130 } + +odukTrailTraceIdentifierMismatchTCM1 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Trail Trace Identifier Mismatch TCM1" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13135 } + +odukTrailTraceIdentifierMismatchTCM2 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Trail Trace Identifier Mismatch TCM2" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13140 } + +odukSignalFailureTCM1 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Signal Failure - TCM1" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13145 } + +odukSignalFailureTCM2 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Signal Failure - TCM2" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13150 } + +odukSignalDegradeTCM1 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Signal Degrade - TCM1" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13155 } + +odukSignalDegradeTCM2 + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "ODUk Signal Degrade - TCM2" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13160 } + +lossOfChannel + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Loss of Channel" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13165 } + +fecMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "FEC Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13170 } + +timSectionMonitorTraceIdentifierMismatchFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "TIM Section Monitor - Trace Identifier Mismatch Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13175 } + +automaticLaserShutdown + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Automatic Laser Shutdown" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13180 } + +shutterInsertionLossVariationDegradeLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Shutter Insertion Loss Variation Degrade Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13200 } + +opticalChannelDeactivationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Channel de-activation failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13205 } + +shutterInsertionLossVariationDegradeHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Shutter Insertion Loss Variation Degrade High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13210 } + +networkTopologyIncomplete + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Network Topology Incomplete" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13215 } + +pluginModuleCommunicationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Plug-in Module Communication Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13220 } + +opticalNetworkTypeMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Network Type Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13225 } + +opticalPowerDegradeLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Optical Power Degrade Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13230 } + +automaticPowerControlFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Automatic Power Control Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13235 } + +opticalPowerDegradeHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Power Degrade High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13240 } + +automaticPowerControlDisabled + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Automatic Power Control Disabled" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13245 } + +opticalPowerFailureLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Power Failure Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13250 } + +ringIdMismatch + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Ring Id Mismatch" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13255 } + +opticalPowerFailureHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Power Failure High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13260 } + +lossOfContinuity + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Loss Of Continuity" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13270 } + +variableOpticalAttenuatorDegradeLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Variable Optical Attenuator Degrade Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13280 } + +variableOpticalAttenuatorDegradeHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Variable Optical Attenuator Degrade High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13290 } + +variableOpticalAttenuatorFailureLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Variable Optical Attenuator Failure Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13300 } + +variableOpticalAttenuatorFailureHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Variable Optical Attenuator Failure High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13310 } + +laserBiasDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Laser Bias Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13320 } + +laserBiasFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "aser Bias Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13330 } + +laserTemperatureDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Laser Temperature Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13340 } + +opticalAmplifierGainDegradeLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Amplifier Gain Degrade Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13350 } + +opticalAmplifierGainDegradeHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Amplifier Gain Degrade High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13360 } + +opticalAmplifierGainFailureLow + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Amplifier Gain Failure Low" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13370 } + +opticalAmplifierGainFailureHigh + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Amplifier Gain Failure High" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13380 } + +opticalChannelConnectionFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Channel connection failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13390 } + +opticalChannelIncomplete + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Channel Incomplete" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13395 } + +opticalChannelActivationFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Channel activation failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13400 } + +laserAutoPowerReduction + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Laser Auto Power Reduction" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13410 } + +caseTemperatureDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Case Temperature Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13420 } + +fiberTemperatureDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Fiber Temperature Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13430 } + +shutterOpen + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Shutter Open" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13440 } + +awgTemperatureDegrade + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "AWG Temperature Degrade" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13450 } + +awgTemperatureFailure + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "AWG Temperature Failure" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13460 } + +awgOverTemperature + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "AWG Over-Temperature" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13470 } + +opticalAmplifierInitialization + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "Optical Amplifier Initialization" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13480 } + +awgWarmUp + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION "AWG Warm Up" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13490 } + +incSigloss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Incoming Signal Loss on Fibre Channel Interface" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13510 } + +incSyncloss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Incoming Synchronization Loss on Fibre Channel Interface" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13515 } + +incGfpOutOfFrame + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Out Of Frame Detected by GFP Receiver" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13520 } + +incGfpSigLoss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Client Signal Loss Frames Detected by GFP Receiver" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13525 } + +incGfpSyncLoss + NOTIFICATION-TYPE + OBJECTS { + cerent454NodeTime, + cerent454AlarmState, + cerent454AlarmObjectType, + cerent454AlarmObjectIndex, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmObjectName, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting + } + STATUS current + DESCRIPTION + "Client Sychronization Loss Frames Detected by GFP Receiver" + --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s" + --#ARGUMENTS {$2, $3, $4, $5, $6, $8} + --#GENERIC 6 + --#SOURCE_ID "A" + --#TIMEINDEX 0 + ::= { cerent454V2Events 13530 } + +node454Group OBJECT-GROUP + OBJECTS { + cerent454SoftwareVersion } + STATUS current + DESCRIPTION + "The group for node related objects" + ::= { cerent454Groups 10 } + +alarm454Group OBJECT-GROUP + OBJECTS { + cerent454AlarmCount, + cerent454AlarmObjectIndex, + cerent454AlarmObjectType, + cerent454AlarmSlotNumber, + cerent454AlarmPortNumber, + cerent454AlarmLineNumber, + cerent454AlarmType, + cerent454AlarmState, + cerent454AlarmSeverity, + cerent454AlarmStatus, + cerent454AlarmServiceAffecting, + cerent454AlarmTimeStamp, + cerent454AlarmObjectName, + cerent454AlarmAdditionalInfo + } + STATUS current + DESCRIPTION + "The group for node related objects" + ::= { cerent454Groups 20 } + +event454Group NOTIFICATION-GROUP + NOTIFICATIONS { + alarmUnknown, + alarmCutoffIsInManualMode, + failureDetectedExternalToTheNE, + externalError, + excessiveSwitching, + sdccTerminationFailure, + incomingFailureCondition, + alarmIndicationSignal, + alarmIndicationSignalLine, + alarmIndicationSignalPath, + alarmIndicationSignalVT, + apsChannelFailure, + channelByteFailureAPS, + channelProtectionSwitchingChannelMatchFailureAPS, + channelAutomaticProtectionSwitchModeMismatchAPS, + farEndProtectionLineFailure, + inconsistentAPSCode, + improperAPSCode, + nodeIdMismatch, + channelDefaultKAPS, + connectionLoss, + bipolarViolation, + carrierLossOnTheLAN, + concatenationErrorSTS, + excessCollisionsOnTheLAN, + facilityFailure, + farEndAIS, + farEndMultipleDS1LOSDetectedOnDS3, + farEndDS1EqptFailNonServiceAffecting, + farEndDS1EqptFailServiceAffecting, + farEndSingleDS1LOS, + farEndDS3EqptFailNonServiceAffecting, + farEndDS3EqptFailServiceAffecting, + farEndCommonEquipmentFailureNonServiceAffecting, + farEndIDLE, + farEndLOS, + farEndLOF, + farEndBlockError, + ds3IdleCondition, + lossOfFrame, + lossOfPointer, + lossOfPointerPath, + lossOfPointerVT, + lossOfSignal, + outOfFrame, + pathSelectorFailure, + remoteAlarmIndication, + remoteFailureIndication, + remoteFailureIndicationLine, + remoteFailureIndicationPath, + remoteFailureIndicationVT, + signalDegrade, + severelyErroredFrame, + signalFailure, + signalLabelMismatchFailure, + payloadDefectIndication, + payloadDefectIndicationPath, + payloadLabelMismatchPath, + signalLabelMismatchFailurePayloadLabelMismatchVT, + unequippedPath, + signalLabelMismatchFailureUnequippedVT, + lossOfSynchronization, + outOfSynchronization, + primarySynchronizationReferenceFailure, + secondarySynchronizationReferenceFailure, + thirdSynchronizationReferenceFailure, + fourthSynchronizationReferenceFailure, + fifthSynchronizationReferenceFailure, + sixthSynchronizationReferenceFailure, + failedToReceiveSynchronizationStatusMessage, + synchronizationStatusMessagesAreDisabledOnThisInterface, + stratum1PrimaryReferenceSourceTraceable, + synchronizedTraceabilityUnknown, + stratum2Traceable, + transitNodeClockTraceable, + stratum3ETraceable, + stratum3Traceable, + sonetMinimumClockTraceable, + stratum4Traceable, + doNotUseForSynchronization, + reservedForNetworkSynchronizationUse, + outgoingFailureCondition, + remoteDefectIndicationLine, + remoteDefectIndicationPath, + freeRunningSynchronizationMode, + holdoverSynchronizationMode, + fastStartSynchronizationMode, + internalFault, + internalError, + internalMessageError, + mismatchOfEquipmentAndAttributes, + watchdogTimerTimeout, + softwareFaultOrFailure, + softwareFaultDataIntegrityFault, + programFailure, + controlEquipmentFailure, + primaryNonVolatileBackupMemoryFailure, + secondaryNonVolatileBackupMemoryFailure, + controlBusFailure, + controlBus1Failure, + controlBus2Failure, + tccAToShelfSlot1DROP1CommunicationFailure, + tccAToShelfSlot2DROP2CommunicationFailure, + tccAToShelfSlot3DROP3CommunicationFailure, + tccAToShelfSlot4DROP4CommunicationFailure, + tccAToShelfSlot5TRUNK1CommunicationFailure, + tccAToShelfSlot6TRUNK2CommunicationFailure, + tccAToShelfSlot7TCCACommunicationFailure, + tccAToShelfSlot8XCONACommunicationFailure, + tccAToShelfSlot9AICCommunicationFailure, + tccAToShelfSlot10XCONBCommunicationFailure, + tccAToShelfSlot11TCCBCommunicationFailure, + tccAToShelfSlot12TRUNK3CommunicationFailure, + tccAToShelfSlot13TRUNK4CommunicationFailure, + tccAToShelfSlot14DROP5CommunicationFailure, + tccAToShelfSlot15DROP6CommunicationFailure, + tccAToShelfSlot16DROP7CommunicationFailure, + tccAToShelfSlot17DROP8CommunicationFailure, + tccAToDCCAProcessorCommunicationFailure, + tccBToShelfSlot1DROP1CommunicationFailure, + tccBToShelfSlot2DROP2CommunicationFailure, + tccBToShelfSlot3DROP3CommunicationFailure, + tccBToShelfSlot4DROP4CommunicationFailure, + tccBToShelfSlot5TRUNK1CommunicationFailure, + tccBToShelfSlot6TRUNK2CommunicationFailure, + tccBToShelfSlot7TCCACommunicationFailure, + tccBToShelfSlot8XCONACommunicationFailure, + tccBToShelfSlot9AICCommunicationFailure, + tccBToShelfSlot10XCONBCommunicationFailure, + tccBToShelfSlot11TCCBCommunicationFailure, + tccBToShelfSlot12TRUNK3CommunicationFailure, + tccBToShelfSlot13TRUNK4CommunicationFailure, + tccBToShelfSlot14DROP5CommunicationFailure, + tccBToShelfSlot15DROP6CommunicationFailure, + tccBToShelfSlot16DROP7CommunicationFailure, + tccBToShelfSlot17DROP8CommunicationFailure, + tccBToDCCBProcessorCommunicationFailure, + controlEquipmentControlCommunicationsEquipmentFailure, + controlProcessorFailure, + workingMemoryFailure, + interconnectionEquipmentFailure, + payloadBusFailureToIOSlot1XCONSlot8, + payloadBusFailureToIOSlot2XCONSlot8, + payloadBusFailureToIOSlot3XCONSlot8, + payloadBusFailureToIOSlot4XCONSlot8, + payloadBusFailureToIOSlot5XCONSlot8, + payloadBusFailureToIOSlot6XCONSlot8, + payloadBusFailureToIOSlot12XCONSlot8, + payloadBusFailureToIOSlot13XCONSlot8, + payloadBusFailureToIOSlot14XCONSlot8, + payloadBusFailureToIOSlot15XCONSlot8, + payloadBusFailureToIOSlot16XCONSlot8, + payloadBusFailureToIOSlot17XCONSlot8, + payloadBusFailureToIOSlot1XCONSlot10, + payloadBusFailureToIOSlot2XCONSlot10, + payloadBusFailureToIOSlot3XCONSlot10, + payloadBusFailureToIOSlot4XCONSlot10, + payloadBusFailureToIOSlot5XCONSlot10, + payloadBusFailureToIOSlot6XCONSlot10, + payloadBusFailureToIOSlot12XCONSlot10, + payloadBusFailureToIOSlot13XCONSlot10, + payloadBusFailureToIOSlot14XCONSlot10, + payloadBusFailureToIOSlot15XCONSlot10, + payloadBusFailureToIOSlot16XCONSlot10, + payloadBusFailureToIOSlot17XCONSlot10, + timeSlotInterchangeEquipmentFailure, + equipmentFailure, + highTemperature, + invalidMACAddress, + boardFailure, + diagnosticFailure, + mediumAccessControlFailure, + facilityTerminationEquipmentFailure, + automaticLaserShutoffDueToHighTemperature, + failureToReleaseFromProtection, + receiverFailure, + transmitFailure, + facilityTerminationEquipmentReceiverMissing, + facilityTerminationEquipmentTransmitterMissing, + failureToSwitchToProtection, + failureToSwitchToProtectionRing, + failureToSwitchToProtectionSpan, + failureToSwitchToProtectionPath, + fanFailure, + equipmentUnitPlugIn, + nePowerFailureAtConnector, + fuseAlarm, + synchronizationUnitFailure, + synchronizationSwitchingEquipmentFailure, + equipmentUnitUnplugged, + loopback, + ds1LoopbackDueToFEACCommand, + loopbackCommandSentToFarEndDS1, + ds3LoopbackDueToFEACCommand, + ds3LoopbackCommandSentToFarEnd, + ds2LoopbackDueToFarEndCommand, + ds2LoopbackCommandSentToFarEnd, + facilityLoopback, + networkLoopback, + terminalLoopback, + manuallyCausedAbnormalCondition, + ethernetBridgeIsNewRootOfSpanningTree, + ethernetBridgeTopologyChange, + normalCondition, + embeddedOperationsChannelFailureLinkDown, + peerStateMismatch, + proceduralError, + improperRemoval, + duplicateNodeID, + blsrOutOfSync, + blsrMultiNodeTableUpdateCompleted, + protectionUnitNotAvailable, + performanceMonitorThresholdCrossingAlert, + protectionSwitch, + recoveryOrServiceProtectionActionHasBeenInitiated, + automaticSystemReset, + automaticUPSRSwitchCausedByAIS, + automaticUPSRSwitchCausedByLOP, + automaticUPSRSwitchCausedByUNEQ, + automaticUPSRSwitchCausedByPDI, + automaticUPSRSwitchCausedBySFBER, + automaticUPSRSwitchCausedBySDBER, + coldRestart, + forcedSwitchBackToWorking, + forcedSwitchBackToWorkingRing, + forcedSwitchBackToWorkingSpan, + forcedSwitchToProtection, + forcedSwitchToProtectionRing, + forcedSwitchToProtectionSpan, + workingFacilityOrEquipmentForcedToSwitchToProtectionPath, + initializationInitiated, + lockoutOfProtection, + lockoutOfProtectionRing, + lockoutOfProtectionSpan, + lockoutOfProtectionPath, + lockoutOfWorking, + lockoutOfWorkingRing, + lockoutOfWorkingSpan, + manualSystemReset, + manualSwitchToInternalClock, + manualSwitchToPrimaryReference, + manualSwitchToSecondReference, + manualSwitchToThirdReference, + manualSwitchToFourthReference, + manualSwitchToFifthReference, + manualSwitchToSixthReference, + manualSwitchBackToWorking, + manualSwitchBackToWorkingRing, + manualSwitchBackToWorkingSpan, + manualSwitchToProtection, + manualSwitchToProtectionRing, + manualSwitchToProtectionSpan, + manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath, + powerfailRestart, + ringIsSquelchingTraffic, + softwareDownloadInProgress, + switchToInternalClock, + switchToPrimaryReference, + switchToSecondReference, + switchToThirdReference, + switchToFourthReference, + switchToFifthReference, + switchToSixthReference, + systemReboot, + switchedBackToWorking, + switchedToProtection, + warmRestart, + ringIsInWaitToRestoreState, + manualSwitchRequest, + forcedSwitchRequest, + lockoutSwitchRequest, + rmonHistoriesAndAlarmsResetReboot, + rmonThresholdCrossingAlarm, + alarmsSuppressedByUserCommand, + alarmsSuppressedForMaintenance, + switchingMatrixModuleFailure, + lanConnectionPolarityReversed, + autonomousPMReportMessageInhibited, + ioSlotToXCONCommunicationFailure, + stsPathTraceIdentifierMismatch, + nePowerFailureAtConnectorA, + nePowerFailureAtConnectorB, + freeMemoryOnCardVeryLow, + freeMemoryOnCardNearZero, + exerciseRequestOnRing, + exerciseRequestOnSpan, + squelchingPath, + extraTrafficPreempted, + farEndLockoutOfWorkingRing, + farEndLockoutOfWorkingSpan, + farEndLockoutOfProtectionRing, + farEndLockoutOfProtectionAllSpans, + farEndWorkingFacilityForcedToSwitchToProtectionRing, + farEndWorkingFacilityForcedToSwitchToProtectionSpan, + farEndManualSwitchOfWorkingFacilityToProtectionRing, + farEndManualSwitchOfWorkingFacilityToProtectionSpan, + farEndExercisingRing, + farEndExercisingSpan, + farEndBERThresholdPassedForSignalFailureRing, + farEndBERThresholdPassedForSignalFailureSpan, + farEndBERThresholdPassedForSignalDegradeRing, + farEndBERThresholdPassedForSignalDegradeSpan, + apsChannelFarEndProtectionLineSignalDegrade, + ringSwitchIsActiveOnTheEastSide, + ringSwitchIsActiveOnTheWestSide, + spanSwitchIsActiveOnTheEastSide, + spanSwitchIsActiveOnTheWestSide, + uniDirectionalFullPassThroughIsActive, + biDirectionalFullPassThroughIsActive, + kBytesPassThroughIsActive, + ringIsSegmented, + ringTopologyIsUnderConstruction, + lockoutOfProtectionAllSpans, + farEndOfFiberIsProvisionedWithDifferentRingID, + bothEndsOfFiberProvisionedAsEastOrBothAsWest, + autonomousMessagesInhibited, + trafficStormOnLANLANTemporarilyDisabled, + reptdbchgMessagesInhibited, + securityUserIDHasExpired, + partialFanFailure, + forcedSwitchRequestOnRing, + forcedSwitchRequestOnSpan, + lockoutSwitchRequestOnRing, + lockoutSwitchRequestOnSpan, + manualSwitchRequestOnRing, + manualSwitchRequestOnSpan, + communicationFailurePeerToPeerSlotControlBusA, + communicationFailurePeerToPeerSlotControlBusB, + controllerAToShelfSlotCommunicationFailure, + controllerBToShelfSlotCommunicationFailure, + interconnectionEquipmentFailureWorkingPayloadBus, + interconnectionEquipmentFailureProtectPayloadBus, + inhibitSwitchToProtectRequestOnEquipment, + inhibitSwitchToWorkingRequestOnEquipment, + exercisingRingSuccessfully, + exercisingSpanSuccessfully, + spanIsInWaitToRestoreState, + exerciseRequestOnRingFailed, + exerciseRequestOnSpanFailed, + farEndLockoutOfProtectionSpan, + manufacturingDataMemoryEEPROMFailure, + replaceableEquipmentOrUnitIsMissing, + softwareDownloadFailed, + extraTrafficPCADropped, + etherTxOversubscribed, + etherRxOverSubscribed, + etherTxExcessFlowCtrl, + etherRxExcessFlowCtrl, + transportLayerFailure, + etherTxUnderrun, + synchronizationReferenceFrequencyOutOfBounds, + ntpOrSntpHostFailure, + peerCardNotResponding, + alarmsAndEventsSuppressedForThisObject, + ds3FrameFormatMismatch, + timSectionTraceIdentifierMismatchFailure, + aisMultiplexSectionAlarmIndicationSignal, + rdiMultiplexSectionRemoteDefectOrAlarmIndication, + timHighOrderTraceIdentifierMismatchFailure, + aisAdministrationUnitAlarmIndicationSignal, + lopAdministrationUnitLossOfPointer, + slmfUnequippedHighOrderPathUnequipped, + slmfPLMHighOrderPathLabelMismatch, + rdiHighOrderRemoteDefectOrAlarmIndication, + lopTributaryUnitLossOfPointer, + aisTributaryUnitAlarmIndicationSignal, + slmfUnequippedLowOrderPathUnequipped, + slmfPLMLowOrderPathLabelMismatch, + timLowOrderTraceIdentifierMismatchFailure, + rfiLowOrderRemoteFailureOrAlarmIndication, + g811PrimaryReferenceClockTraceable, + g812TransitNodeClockTraceable, + g812LocalNodeClockTraceable, + g813SynchronousEquipmentTimingSourceTraceable, + e1LoopbackDueToFEACCommand, + e1LoopbackCommandSentToFarEnd, + e3LoopbackDueToFEACCommand, + farEndMultipleE1LOSDetectedOnE3, + farEndE1EqptFailNonServiceAffecting, + farEndE1EqptFailServiceAffecting, + farEndSingleE1LOS, + farEndE3EqptFailServiceAffecting, + e3LoopbackCommandSentToFarEnd, + farEndE3EqptFailNonServiceAffecting, + lowVoltBatteryA, + highVoltBatteryA, + lowVoltBatteryB, + highVoltBatteryB, + msspRingOutOfSync, + msspMultiNodeTableUpdateCompleted, + automaticSNCPSwitchCausedByAIS, + automaticSNCPSwitchCausedByLOP, + automaticSNCPSwitchCausedByUNEQ, + automaticSNCPSwitchCausedByPDI, + automaticSNCPSwitchCausedBySFBER, + automaticSNCPSwitchCausedBySDBER, + stmConcatenationError, + e3IdleCondition, + channelMSSPInconsistentAPSCode, + channelMSSPImproperAPSCodeAPS, + channelMSSPNodeIdMismatchAPS, + channelMSSPDefaultKAPS, + channelMSSPConnectionLossAPS, + minimumClockTraceableSDH, + lineIsInWaitToRestoreStateSDH, + berThresholdExceededForSignalDegradeHighOrder, + berThresholdExceededForSignalFailureHighOrder, + berThresholdExceededForSignalDegradeLowOrder, + berThresholdExceededForSignalFailureLowOrder, + failureToSwitchToProtectionHighOrderPath, + failureToSwitchToProtectionLowOrderPath, + a8b10bOutOfSync, + odukPMAlarmIndicationSignal, + otukAlarmIndicationSignal, + otukSMBackwardDefectIndication, + odukBackwardDefectIndication, + fecUncorrectedWord, + gccTerminationFailure, + otukIncomingAlignmentError, + odukLockedDefectPM, + lossOfMultiFrame, + odukOpenConnectionIndication, + payloadTypeIdentifierMismatch, + odukTrailTraceIdentifierMismatch, + otukTrailTraceIdentifierMismatch, + equipmentHighLaserBias, + equipmentHighLaserTemp, + equipmentHighLaserPeltier, + facilityHighRxPower, + equipmentHighTxPower, + equipmentHighTransceiverVoltage, + equipmentLowLaserBias, + equipmentLowLaserTemp, + equipmentLowLaserPeltier, + facilityLowRxPower, + equipmentLowTxPower, + equipmentLowTransceiverVoltage, + equipmentRxLocked, + equipmentSquelched, + equipmentTxLocked, + otukSignalFailure, + odukSignalFailure, + otukSignalDegrade, + odukSignalDegrade, + pluggablePortMissing, + pluggablePortRateMismatch, + pluggablePortSecurityCodeMismatch, + tciNotSelected, + tci1ClockFailure, + odukPMBackwardDefectIndication, + odukTCM1BackwardDefectIndication, + odukTCM2BackwardDefectIndication, + equipmentHighRxTemperature, + equipmentLowRxTemperature, + tci2ClockFailure, + equipmentWavelengthMismatch, + dspCommunicationFailure, + dspFailure, + laserApproachingEndOfLife, + crossconnectLoopback, + adminLogoutOfUser, + userLockedOut, + adminLockoutOfUser, + adminLockoutClear, + invalidLoginUsername, + securityInvalidLoginPassword, + securityInvalidLoginLockedOut, + securityInvalidLoginAlreadyLoggedOn, + loginOfUser, + automaticLogoutOfIdleUser, + logoutOfUser, + firewallHasBeenDisabled, + connectionEquipmentMismatch, + disableInactiveUser, + disableInactiveClear, + batteryFailure, + extremeHighVolt, + extremeLowVolt, + highVolt, + lowVolt, + suspendUser, + suspendUserClear, + lineDccTerminationFailure, + multiplexSectionDccTerminationFailure, + gigaBitEthernetOutOfSync, + sequenceMismatch, + lossOfAlignment, + outOfUseByAdministrativeCommand, + outOfUseTransportFailure, + vcatGroupDown, + vcatGroupDegraded, + vcatGroupIncomplete, + alarmIndicationSignalInTX, + remoteAlarmIndicationInTX, + kByteAPSChannelFailure, + apsInvalidMode, + ipAddressAlreadyInUseWithinTheSameDccArea, + nodeNameInUseWithinTheSameDccArea, + rearPanelEthernetLinkRemoved, + manualSwitchToProtectResultedInNoTrafficSwitch, + manualSwitchBackToWorkingResultedInNoTrafficSwitch, + forcedSwitchToProtectResultedInNoTrafficSwitch, + forcedSwitchBackToWorkingResultedInNoTrafficSwitch, + duplicateSerialNumberDetectedOnAPluggableEntity, + lossOfSignalForOpticalChannel, + encapsulationMismatchPath, + encapsulationMismatchVT, + encapsulationMismatchHighOrderPath, + encapsulationMismatchLowOrderPath, + gfpUserPayloadMismatch, + gfpFibreChannelDistanceExtensionMismatch, + gfpFibreChannelDistanceExtensionBufferStarvation, + gfpFibreChannelDistanceExtensionCreditStarvation, + gfpClientSignalFailDetected, + gfpLossOfFrameDelineation, + gfpExtensionHeaderMismatch, + lcasVcgMemberTxSideInAddState, + lcasVcgMemberTxSideInDnuState, + lcasControlWordCrcCheckFailure, + lcasVcgMemberRxSideInFailState, + signalLossOnDataInterface, + synchronizationLossOnDataInterface, + portFAIL, + unreachablePortTargetPower, + portAddPowerDegradeLow, + portAddPowerDegradeHigh, + portAddPowerFailLow, + portAddPowerFailHigh, + automaticWdmAnsFinished, + incomingOverheadSignalAbsent, + opticalSafetyRemoteInterlockOn, + automaticPowerControlCorrectionSkipped, + apcCannotSetValueDueToRangeLimits, + farEndManualSwitchBackToWorkingSpan, + farEndForcedSwitchBackToWorkingSpan, + universalTransponderModuleHardwareFailure, + universalTransponderModuleCommunicationFailure, + pluginModuleRangeSettingsMismatch, + automaticPowerControlTerminatedOnManualRequest, + oduk1AlarmIndicationSignal, + oduk2AlarmIndicationSignal, + oduk3AlarmIndicationSignal, + oduk4AlarmIndicationSignal, + temperatureReadingMismatchBetweenSCCards, + voltageReadingMismatchBetweenSCCards, + alarmsSuppressedonOutOfGroupVcatMember, + blsrSoftwareVersionMismatch, + optimized1Plus1ApsPrimaryFacility, + optimized1Plus1ApsPrimarySectionMismatch, + optimized1Plus1ApsInvalidPrimarySection, + compositeClockHighLineVoltage, + berThresholdExceededForSignalDegradeVt, + berThresholdExceededForSignalFailureVt, + spanLengthOutOfRange, + idleSignalCondition, + idleSignalConditionInTx, + vtPathTraceIdentifierMismatch, + lossOfFrameInTX, + provisioningMismatch, + sectionTraceIdentifierMismatch, + regeneratorSectionTraceIdentifierMismatch, + switchingMatrixModuleFailureWorking, + switchingMatrixModuleFailureProtect, + slotCommunicationDisabled, + sessionTimeLimitExpired, + userPasswordChangeRequired, + isisAdjacencyFailure, + msspSoftwareVersionMismatch, + remoteAuthenticationFailSeeAuditLog, + ringIsSquelchingStsTraffic, + ringIsSquelchingVtTraffic, + archiveOfAuditLogFailed, + rprWrapped, + shelfCommunicationFailure, + duplicatedShelfIdentifier, + softwareMismatch, + lmpFailure, + opticalTerminationIncomplete, + forwardDefectIndication, + payloadMissingIndication, + spanMeasurementCannotBePerformed, + ringIsSquelchingHighOrderTraffic, + ringIsSquelchingLowOrderTraffic, + badPacketCountExceedsThreshold, + linkLayerKeepAliveFailure, + autonegotiationRemoteFailureIndication, + trailSignalFail, + ds1LoopbackCommandSentToFarEnd, + multiplexSectionSignalDegraded, + multiplexSectionExcessiveErrors, + highOrderPathSignalDegraded, + highOrderPathExcessiveErrors, + lowOrderPathSignalDegraded, + lowOrderPathExcessiveErrors, + regeneratorSectionDccTerminationFailure, + networkMemoryPoolLow, + ospfRoutingTableOverflow, + autoLaserShutdownDisabled, + rprProtectionIsActive, + maxRPRStationNumberExceeded, + rprProtectionConfigurationMismatched, + reservedBandwidthLinkRateExceededOnRinglet0, + reservedBandwidthLinkRateExceededOnRinglet1, + rprInterfaceInPassThroughMode, + rprPeerNodeIsMissing, + rprRiFailure, + rprSignalFailure, + rprSignalDegrade, + interlinkFailure, + apcWrongGain, + rprSpanMismatch, + efmRemoteFaultIndicationCriticalEvent, + efmRemoteFaultIndicationDyingGasp, + efmRemoteFaultIndicationLinkFault, + efmLinkMonitoringErroredSymbolPeriodEvent, + efmLinkMonitoringErroredFrameEvent, + efmLinkMonitoringErroredFramePeriodEvent, + efmLinkMonitoringErroredFrameSecondsSummary, + efmRemoteLoopbackRequestFailed, + fastAutomaticProtectionSwitching, + fastAutomaticProtectionSwitchingConfigMismatch, + lcasSinkGroupError, + lcasVcgMemberRxSideInDnuState, + fcDistanceExtFuncNotEstablished, + nonCiscoPPMInserted, + unqualifiedPPMInserted, + ftaMismatch, + cardPortsUnableToProvideProtection, + lmpSignalDegrade, + lmpSignalFailure, + lmpUnallocatedDataLink, + frontPortLinkLoss, + bertEnbl, + bertSyncFail, + workQueueFull, + equipmentPowerFailureAtConnectorA, + equipmentPowerFailureAtConnectorB, + equipmentPowerFailureAtReturnConnectorA, + equipmentPowerFailureAtReturnConnectorB, + ospfHelloFail, + openIOSlots, + lossOfClockFromMateShelfController, + virtualLanAlarmIndicationSignal, + dcuLossFailure, + ochncMaintenance, + ramanLaserShutdown, + losOfRamanSignal, + mcastMacTableFull, + multicastMacAddressAliasing, + ramanPwrProtOn, + cppPeerNotResponding, + voaControlLoopDisableDueToExcessiveCounterPropagationLight, + wizardIsRunning, + ramanGainNotReached, + localFault, + remoteFault, + efmRemoteLoopbackConfigured, + efmPeerMissing, + eqptDegrade, + excessiveBackPropagation, + remoteMaintenanceEndPointIsDown, + crossConnectedCFMService, + cfmLoop, + cfmConfigurationError, + outOfChannelGroupBundle, + repNeighborAdjacencyFailure, + repLinkFlapping, + faultInREPSegment, + primaryREPEdgePortElected, + secondaryREPEdgePortElected, + stcnREPGenerated, + vlbREPActivated, + vlbREPTriggerSoakingDelayActive, + pprForwardDefectIndication, + pprBackwardDefectIndication, + pprCoordinatedMaintenance, + pprTriggerThresholdBERExceeded, + wanSyncloss, + laserShutdownDueToWavelengthDrift, + manualLaserRestart, + laserShutdownDueToNonCiscoPPMInserted, + ethernetOSCTerminationFailure, + enhancedRemoteFailureIndicationPathServer, + enhancedRemoteFailureIndicationPathConnectivity, + enhancedRemoteFailureIndicationPathPayload, + securityIntrusionDetPwd, + securityIntrusionDetUser, + backPanelFacilityLoopback, + backPanelTerminalLoopback, + trunkPayloadTypeMismatch, + invalidMuxponderConfiguration, + coolingProfileMismatch, + trunkOduAlarmIndicationSignal, + companionCardMissing, + masterKeyExchangeFailed, + powerConsumptionLimitHasCrossed, + controlPlaneUnverifiedClearedAlarmsPresent, + unitHighTemperature, + overTemperatureUnitProtected, + seqMismatchCount, + keyProgramOnAlteraFpgaFailed, + duplicateNodeControllerDetected, + restorationInProg, + ramanPumpsCalibrationProcedureIsRunning, + ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes, + odukTCM1AlarmIndicationSignal, + odukTCM2AlarmIndicationSignal, + odukLockedDefectTCM1, + odukLockedDefectTCM2, + otukLossOfFrame, + odukOpenConnectionIndicationTCM1, + odukOpenConnectionIndicationTCM2, + odukTrailTraceIdentifierMismatchTCM1, + odukTrailTraceIdentifierMismatchTCM2, + odukSignalFailureTCM1, + odukSignalFailureTCM2, + odukSignalDegradeTCM1, + odukSignalDegradeTCM2, + lossOfChannel, + fecMismatch, + timSectionMonitorTraceIdentifierMismatchFailure, + automaticLaserShutdown, + shutterInsertionLossVariationDegradeLow, + opticalChannelDeactivationFailure, + shutterInsertionLossVariationDegradeHigh, + networkTopologyIncomplete, + pluginModuleCommunicationFailure, + opticalNetworkTypeMismatch, + forcedSwitchToPrimaryReference, + forcedSwitchToSecondReference, + forcedSwitchToThirdReference, + forcedSwitchToInternalClock, + industrialHighTemperature, + opticalPowerDegradeLow, + automaticPowerControlFailure, + opticalPowerDegradeHigh, + automaticPowerControlDisabled, + opticalPowerFailureLow, + ringIdMismatch, + opticalPowerFailureHigh, + lossOfContinuity, + variableOpticalAttenuatorDegradeLow, + variableOpticalAttenuatorDegradeHigh, + variableOpticalAttenuatorFailureLow, + variableOpticalAttenuatorFailureHigh, + laserBiasDegrade, + laserBiasFailure, + laserTemperatureDegrade, + opticalAmplifierGainDegradeLow, + opticalAmplifierGainDegradeHigh, + opticalAmplifierGainFailureLow, + opticalAmplifierGainFailureHigh, + opticalChannelConnectionFailure, + opticalChannelIncomplete, + opticalChannelActivationFailure, + laserAutoPowerReduction, + caseTemperatureDegrade, + fiberTemperatureDegrade, + shutterOpen, + awgTemperatureDegrade, + awgTemperatureFailure, + awgOverTemperature, + opticalAmplifierInitialization, + awgWarmUp, + incSigloss, + incSyncloss, + incGfpOutOfFrame, + incGfpSigLoss, + incGfpSyncLoss, + bridgeAndRollHasOccurred, + bridgeAndRollIsPendingAValidSignal, + clockBusFailureTscA, + clockBusFailureTscB, + waitToRestore, + extremeHighVoltBatteryA, + extremeLowVoltBatteryA, + extremeHighVoltBatteryB, + extremeLowVoltBatteryB, + iosConfigCopyFailed, + iosConfigCopyInProgress, + iosConfigCopySuccess, + signalingUnableToSetupCircuit, + errorInStartupConfig, + noStartupConfig, + needToSaveRunningConfig, + invalidAlarm, + rsvpHelloFSMToNeighborDown, + securityInvalidLoginUsername, + databaseBackupFailed, + databaseRestoreFailed, + lmpHelloFSMToControlChannelDown, + lmpNeighborDiscoveryHasFailed, + auditLog80PercentFull, + moduleCommunicationFailure, + auditLog100PercentFullOldestRecordsWillBeLost, + standbyDatabaseOutOfSync, + redundantPowerCapabilityLost, + lofAdministrationUnitLossOfMultiFrame, + sdhSpanIsInWaitToRestoreState, + berThresholdExceededForSignalDegradeLine, + berThresholdExceededForSignalDegradePath, + berThresholdExceededForSignalFailureLine, + berThresholdExceededForSignalFailurePath, + unauthorizedIncomingSignalingRequest + } + STATUS current + DESCRIPTION + "The notifications for Cisco ONS 15454" + ::= { cerent454Groups 30 } + +-- This definition of group will move to a cerentCommon modules +-- eventually. + +cerent454CommonGroup OBJECT-GROUP + OBJECTS { +-- cerentNotificationCategory, + cerent454EnableNotification, + cerent454NodeTime, + cerent454SentNotifications, + cerent454LastChangeTime, + cerent454MultishelfEnabled + } + STATUS current + DESCRIPTION + "The objects for storing all the current alarms" + ::= { cerent454Groups 40 } + +-- This group covers for threshold display and TCA trap + +cerentThresholdGroup OBJECT-GROUP + OBJECTS { + cerent454ThresholdMonitorType, + cerent454ThresholdLocation, + cerent454ThresholdPeriod, + cerent454ThresholdSetValue, + cerent454ThresholdCurrentValue, + cerent454ThresholdDetectType + } + STATUS current + DESCRIPTION + "The objects for storing all the current alarms" + ::= { cerent454Groups 50 } + +event454DeprecatedGroup NOTIFICATION-GROUP + NOTIFICATIONS { + securityInvalidLoginUsernameSeeAuditTrail + } + STATUS deprecated + DESCRIPTION + "The notifications for Cisco ONS 15454 that have been deprecated" + ::= { cerent454Groups 60 } + +reportedAlarm454Group OBJECT-GROUP + OBJECTS { + cerent454ReportedAlarmCount, + cerent454ReportedAlarmObjectType, + cerent454ReportedAlarmSlotNumber, + cerent454ReportedAlarmPortNumber, + cerent454ReportedAlarmObjectIndex, + cerent454ReportedAlarmType, + cerent454ReportedAlarmTimeStamp, + cerent454ReportedAlarmObjectName, + cerent454ReportedAlarmAdditionalInfo, + cerent454ReportedAlarmSeverity, + cerent454ReportedAlarmStatus, + cerent454ReportedAlarmServiceAffecting + } + STATUS current + DESCRIPTION + "The group for reported alarm objects" + ::= { cerent454Groups 80 } + + +-- the compliance specification for agent developers + +cerent454BasicCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The basic implementation requirements for Cisco ONS 15454 MIB" + MODULE + MANDATORY-GROUPS { + node454Group, + event454Group + } + ::= { cerent454Compliance 10 } + +END |