+-- Cerent-454-MIB module
+--
+-- This module contains the objects and events for the
+-- Cisco ONS 15454
+
+-- Copyright (c) 1998-1999 by Cerent Corporation, Inc.
+-- Copyright (c) 2000-2002, 2004-2005 by Cisco Systems, Inc.
+-- All rights reserved.
+--
+-- **************************************************************
+
+CERENT-454-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ OBJECT-IDENTITY,
+ NOTIFICATION-TYPE,
+ Integer32,
+ Unsigned32,
+ Counter32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION,
+ DisplayString,
+ TruthValue,
+ TimeStamp
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE,
+ OBJECT-GROUP,
+ NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ cerentProducts,
+ cerentModules
+ FROM CERENT-GLOBAL-REGISTRY
+ CerentNotificationClass,
+ CerentAlarmSeverity,
+ CerentAlarmStatus,
+ CerentAlarmServiceAffecting,
+ CerentMonitorType,
+ CerentLocation,
+ CerentPeriod,
+ CerentPortNumber
+ FROM CERENT-TC;
+
+cerent454MibModule MODULE-IDENTITY
+ LAST-UPDATED "0410010000Z" -- 2004/Oct/01
+ ORGANIZATION "Cisco Systems, Inc."
+ CONTACT-INFO
+ " support@Cisco.com
+
+ Postal: Cisco Systems
+ 1450 N. McDowell Blvd.
+ Petaluma, CA 94954
+ USA
+
+ Tel: +1-877-323-7368"
+ DESCRIPTION
+ "This module provides the definitions for
+ objects for managing Cisco OTBU ONS 15454."
+
+ REVISION "0410010000Z" -- 2004/Oct/01
+ DESCRIPTION
+ "This file can be used with R5.0 release."
+
+ ::= { cerentModules 20 }
+
+cerent454Mib OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The is the node under which all Cisco ONS 15454
+ specific mib object are located."
+ ::= { cerentProducts 10 }
+
+cerent454Conformance OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "This node is created compliance. Has
+ objects as required by the RFCs"
+ ::= { cerent454Mib 10 }
+
+-- ********************************************************
+
+cerentCommonObjects OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The objects here are expected to be
+ used by all Cisco OTBU Products.
+ These will be mixed with specific
+ objects of the product-specific branch."
+ ::= { cerent454Mib 100 }
+--
+cerentCommonEvents OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "This branch is similar to cerentCommonObjects,
+ except that this will have only events"
+ ::= { cerent454Mib 200 }
+
+-- ********************************************************
+
+cerent454Groups OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { cerent454Conformance 10 }
+
+cerent454Compliance OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { cerent454Conformance 20 }
+
+-- **************************************************************
+-- Cisco ONS 15454 specific textual conventions
+-- **************************************************************
+
+Cerent454AlarmType ::= TEXTUAL-CONVENTION
+ -- DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "This TC is used by the NMS to map the alarm type
+ received by the trap and and display the string
+ shown in LHS."
+ SYNTAX INTEGER {
+ alarmUnknown ( 1 ),
+ alarmCutoffIsInManualMode ( 10 ),
+ failureDetectedExternalToTheNE ( 20 ),
+ externalError ( 30 ),
+ excessiveSwitching ( 40 ),
+ sdccTerminationFailure ( 50 ),
+ incomingFailureCondition ( 60 ),
+ alarmIndicationSignal ( 70 ),
+ alarmIndicationSignalLine ( 80 ),
+ alarmIndicationSignalPath ( 90 ),
+ alarmIndicationSignalVT ( 100 ),
+ apsChannelFailure ( 110 ),
+ channelByteFailureAPS ( 120 ),
+ channelProtectionSwitchingChannelMatchFailureAPS ( 130 ),
+ channelAutomaticProtectionSwitchModeMismatchAPS ( 140 ),
+ farEndProtectionLineFailure ( 150 ),
+ inconsistentAPSCode ( 160 ),
+ improperAPSCode ( 170 ),
+ nodeIdMismatch ( 180 ),
+ channelDefaultKAPS ( 190 ),
+ connectionLoss ( 200 ),
+
+ bipolarViolation ( 210 ),
+ carrierLossOnTheLAN ( 220 ),
+ concatenationErrorSTS ( 230 ),
+ excessCollisionsOnTheLAN ( 240 ),
+ facilityFailure ( 250 ),
+ farEndAIS ( 260 ),
+ farEndMultipleDS1LOSDetectedOnDS3 ( 270 ),
+ farEndDS1EqptFailNonServiceAffecting ( 280 ),
+ farEndDS1EqptFailServiceAffecting ( 290 ),
+ farEndSingleDS1LOS ( 300 ),
+ farEndDS3EqptFailNonServiceAffecting ( 310 ),
+ farEndDS3EqptFailServiceAffecting ( 320 ),
+ farEndCommonEquipmentFailureNonServiceAffecting ( 330 ),
+ farEndIDLE ( 340 ),
+ farEndLOS ( 350 ),
+ farEndLOF ( 360 ),
+ farEndBlockError ( 370 ),
+ ds3IdleCondition ( 380 ),
+ lossOfFrame ( 390 ),
+ lossOfPointer ( 400 ),
+
+ lossOfPointerPath ( 410 ),
+ lossOfPointerVT ( 420 ),
+ lossOfSignal ( 430 ),
+ outOfFrame ( 440 ),
+ pathSelectorFailure ( 450 ),
+ remoteAlarmIndication ( 460 ),
+ remoteFailureIndication ( 470 ),
+ remoteFailureIndicationLine ( 480 ),
+ remoteFailureIndicationPath ( 490 ),
+ remoteFailureIndicationVT ( 500 ),
+
+ signalDegrade ( 510 ),
+ severelyErroredFrame ( 520 ),
+ signalFailure ( 530 ),
+ signalLabelMismatchFailure ( 540 ),
+ payloadDefectIndication ( 550 ),
+
+ payloadDefectIndicationPath ( 560 ),
+ payloadLabelMismatchPath ( 570 ),
+ signalLabelMismatchFailurePayloadLabelMismatchVT ( 580 ),
+ unequippedPath ( 590 ),
+ signalLabelMismatchFailureUnequippedVT ( 600 ),
+ lossOfSynchronization ( 610 ),
+ outOfSynchronization ( 620 ),
+ primarySynchronizationReferenceFailure ( 630 ),
+ secondarySynchronizationReferenceFailure ( 640 ),
+ thirdSynchronizationReferenceFailure ( 650 ),
+ fourthSynchronizationReferenceFailure ( 660 ),
+ fifthSynchronizationReferenceFailure ( 670 ),
+ sixthSynchronizationReferenceFailure ( 680 ),
+
+ failedToReceiveSynchronizationStatusMessage ( 690 ),
+ synchronizationStatusMessagesAreDisabledOnThisInterface ( 700 ),
+ stratum1PrimaryReferenceSourceTraceable ( 710 ),
+ synchronizedTraceabilityUnknown ( 720 ),
+ stratum2Traceable ( 730 ),
+ transitNodeClockTraceable ( 740 ),
+
+ stratum3ETraceable ( 750 ),
+ stratum3Traceable ( 760 ),
+ sonetMinimumClockTraceable ( 770 ),
+ stratum4Traceable ( 780 ),
+ doNotUseForSynchronization ( 790 ),
+ reservedForNetworkSynchronizationUse ( 800 ),
+
+ outgoingFailureCondition ( 810 ),
+ remoteDefectIndicationLine ( 820 ),
+ remoteDefectIndicationPath ( 830 ),
+ freeRunningSynchronizationMode ( 840 ),
+ holdoverSynchronizationMode ( 850 ),
+ fastStartSynchronizationMode ( 860 ),
+ internalFault ( 870 ),
+ internalError ( 880 ),
+ internalMessageError ( 890 ),
+ mismatchOfEquipmentAndAttributes ( 900 ),
+ watchdogTimerTimeout ( 910 ),
+ softwareFaultOrFailure ( 920 ),
+ softwareFaultDataIntegrityFault ( 930 ),
+ programFailure ( 940 ),
+
+ controlEquipmentFailure ( 950 ),
+ primaryNonVolatileBackupMemoryFailure ( 960 ),
+ secondaryNonVolatileBackupMemoryFailure ( 970 ),
+ controlBusFailure ( 980 ),
+ controlBus1Failure ( 990 ),
+ controlBus2Failure ( 1000 ),
+
+ tccAToShelfSlot1DROP1CommunicationFailure ( 1010 ),
+ tccAToShelfSlot2DROP2CommunicationFailure ( 1020 ),
+ tccAToShelfSlot3DROP3CommunicationFailure ( 1030 ),
+ tccAToShelfSlot4DROP4CommunicationFailure ( 1040 ),
+ tccAToShelfSlot5TRUNK1CommunicationFailure ( 1050 ),
+ tccAToShelfSlot6TRUNK2CommunicationFailure ( 1060 ),
+ tccAToShelfSlot7TCCACommunicationFailure ( 1070 ),
+ tccAToShelfSlot8XCONACommunicationFailure ( 1080 ),
+ tccAToShelfSlot9AICCommunicationFailure ( 1090 ),
+ tccAToShelfSlot10XCONBCommunicationFailure ( 1100 ),
+ tccAToShelfSlot11TCCBCommunicationFailure ( 1110 ),
+ tccAToShelfSlot12TRUNK3CommunicationFailure ( 1120 ),
+ tccAToShelfSlot13TRUNK4CommunicationFailure ( 1130 ),
+ tccAToShelfSlot14DROP5CommunicationFailure ( 1140 ),
+ tccAToShelfSlot15DROP6CommunicationFailure ( 1150 ),
+ tccAToShelfSlot16DROP7CommunicationFailure ( 1160 ),
+ tccAToShelfSlot17DROP8CommunicationFailure ( 1170 ),
+ tccAToDCCAProcessorCommunicationFailure ( 1180 ),
+ tccBToShelfSlot1DROP1CommunicationFailure ( 1190 ),
+ tccBToShelfSlot2DROP2CommunicationFailure ( 1200 ),
+ tccBToShelfSlot3DROP3CommunicationFailure ( 1210 ),
+ tccBToShelfSlot4DROP4CommunicationFailure ( 1220 ),
+ tccBToShelfSlot5TRUNK1CommunicationFailure ( 1230 ),
+ tccBToShelfSlot6TRUNK2CommunicationFailure ( 1240 ),
+ tccBToShelfSlot7TCCACommunicationFailure ( 1250 ),
+ tccBToShelfSlot8XCONACommunicationFailure ( 1260 ),
+ tccBToShelfSlot9AICCommunicationFailure ( 1270 ),
+ tccBToShelfSlot10XCONBCommunicationFailure ( 1280 ),
+ tccBToShelfSlot11TCCBCommunicationFailure ( 1290 ),
+ tccBToShelfSlot12TRUNK3CommunicationFailure ( 1300 ),
+ tccBToShelfSlot13TRUNK4CommunicationFailure ( 1310 ),
+ tccBToShelfSlot14DROP5CommunicationFailure ( 1320 ),
+ tccBToShelfSlot15DROP6CommunicationFailure ( 1330 ),
+ tccBToShelfSlot16DROP7CommunicationFailure ( 1340 ),
+ tccBToShelfSlot17DROP8CommunicationFailure ( 1350 ),
+ tccBToDCCBProcessorCommunicationFailure ( 1360 ),
+
+ controlEquipmentControlCommunicationsEquipmentFailure ( 1370 ),
+ controlProcessorFailure ( 1380 ),
+ workingMemoryFailure ( 1390 ),
+
+ interconnectionEquipmentFailure ( 1400 ),
+ payloadBusFailureToIOSlot1XCONSlot8 ( 1410 ),
+ payloadBusFailureToIOSlot2XCONSlot8 ( 1420 ),
+ payloadBusFailureToIOSlot3XCONSlot8 ( 1430 ),
+ payloadBusFailureToIOSlot4XCONSlot8 ( 1440 ),
+ payloadBusFailureToIOSlot5XCONSlot8 ( 1450 ),
+ payloadBusFailureToIOSlot6XCONSlot8 ( 1460 ),
+ payloadBusFailureToIOSlot12XCONSlot8 ( 1470 ),
+ payloadBusFailureToIOSlot13XCONSlot8 ( 1480 ),
+ payloadBusFailureToIOSlot14XCONSlot8 ( 1490 ),
+ payloadBusFailureToIOSlot15XCONSlot8 ( 1500 ),
+ payloadBusFailureToIOSlot16XCONSlot8 ( 1510 ),
+ payloadBusFailureToIOSlot17XCONSlot8 ( 1520 ),
+ payloadBusFailureToIOSlot1XCONSlot10 ( 1530 ),
+ payloadBusFailureToIOSlot2XCONSlot10 ( 1540 ),
+ payloadBusFailureToIOSlot3XCONSlot10 ( 1550 ),
+ payloadBusFailureToIOSlot4XCONSlot10 ( 1560 ),
+ payloadBusFailureToIOSlot5XCONSlot10 ( 1570 ),
+ payloadBusFailureToIOSlot6XCONSlot10 ( 1580 ),
+ payloadBusFailureToIOSlot12XCONSlot10 ( 1590 ),
+ payloadBusFailureToIOSlot13XCONSlot10 ( 1600 ),
+ payloadBusFailureToIOSlot14XCONSlot10 ( 1610 ),
+ payloadBusFailureToIOSlot15XCONSlot10 ( 1620 ),
+ payloadBusFailureToIOSlot16XCONSlot10 ( 1630 ),
+ payloadBusFailureToIOSlot17XCONSlot10 ( 1640 ),
+ timeSlotInterchangeEquipmentFailure ( 1650 ),
+
+ equipmentFailure ( 1660 ),
+ highTemperature ( 1670 ),
+ invalidMACAddress ( 1680 ),
+ boardFailure ( 1690 ),
+ diagnosticFailure ( 1700 ),
+ mediumAccessControlFailure ( 1710 ),
+ facilityTerminationEquipmentFailure ( 1720 ),
+ automaticLaserShutoffDueToHighTemperature ( 1730 ),
+ failureToReleaseFromProtection ( 1740 ),
+ receiverFailure ( 1750 ),
+ transmitFailure ( 1760 ),
+ facilityTerminationEquipmentReceiverMissing ( 1770 ),
+ facilityTerminationEquipmentTransmitterMissing ( 1780 ),
+ failureToSwitchToProtection ( 1790 ),
+ failureToSwitchToProtectionRing ( 1800 ),
+
+ failureToSwitchToProtectionSpan ( 1810 ),
+ failureToSwitchToProtectionPath ( 1820 ),
+ fanFailure ( 1830 ),
+ equipmentUnitPlugIn ( 1840 ),
+ nePowerFailureAtConnector ( 1850 ),
+ fuseAlarm ( 1860 ),
+ synchronizationUnitFailure ( 1870 ),
+ synchronizationSwitchingEquipmentFailure ( 1880 ),
+ equipmentUnitUnplugged ( 1890 ),
+ loopback ( 1900 ),
+
+ ds1LoopbackDueToFEACCommand ( 1910 ),
+ loopbackCommandSentToFarEndDS1 ( 1920 ),
+ ds3LoopbackDueToFEACCommand ( 1930 ),
+ ds3LoopbackCommandSentToFarEnd ( 1940 ),
+ ds2LoopbackDueToFarEndCommand ( 1950 ),
+ ds2LoopbackCommandSentToFarEnd ( 1960 ),
+ facilityLoopback ( 1970 ),
+ networkLoopback ( 1980 ),
+ terminalLoopback ( 1990 ),
+ manuallyCausedAbnormalCondition ( 2000 ),
+ ethernetBridgeIsNewRootOfSpanningTree ( 2010 ),
+ ethernetBridgeTopologyChange ( 2020 ),
+ normalCondition ( 2030 ),
+ embeddedOperationsChannelFailureLinkDown ( 2040 ),
+ peerStateMismatch ( 2050 ),
+ proceduralError ( 2060 ),
+ improperRemoval ( 2070 ),
+ duplicateNodeID ( 2080 ),
+ blsrOutOfSync ( 2090 ),
+ blsrMultiNodeTableUpdateCompleted ( 2100 ),
+ protectionUnitNotAvailable ( 2110 ),
+ performanceMonitorThresholdCrossingAlert ( 2120 ),
+ protectionSwitch ( 2130 ),
+ recoveryOrServiceProtectionActionHasBeenInitiated ( 2140 ),
+ automaticSystemReset ( 2150 ),
+ automaticUPSRSwitchCausedByAIS ( 2160 ),
+ automaticUPSRSwitchCausedByLOP ( 2170 ),
+ automaticUPSRSwitchCausedByUNEQ ( 2180 ),
+ automaticUPSRSwitchCausedByPDI ( 2190 ),
+ automaticUPSRSwitchCausedBySFBER ( 2200 ),
+ automaticUPSRSwitchCausedBySDBER ( 2210 ),
+ coldRestart ( 2220 ),
+ forcedSwitchBackToWorking ( 2230 ),
+ forcedSwitchBackToWorkingRing ( 2240 ),
+ forcedSwitchBackToWorkingSpan ( 2250 ),
+ forcedSwitchToProtection ( 2260 ),
+
+ forcedSwitchToProtectionRing ( 2270 ),
+ forcedSwitchToProtectionSpan ( 2280 ),
+ workingFacilityOrEquipmentForcedToSwitchToProtectionPath ( 2290 ),
+
+ initializationInitiated ( 2300 ),
+ lockoutOfProtection ( 2310 ),
+ lockoutOfProtectionRing ( 2320 ),
+ lockoutOfProtectionSpan ( 2330 ),
+ lockoutOfProtectionPath ( 2340 ),
+ lockoutOfWorking ( 2350 ),
+ lockoutOfWorkingRing ( 2360 ),
+ lockoutOfWorkingSpan ( 2370 ),
+
+ manualSystemReset ( 2380 ),
+
+ manualSwitchToInternalClock ( 2390 ),
+ manualSwitchToPrimaryReference ( 2400 ),
+ manualSwitchToSecondReference ( 2410 ),
+ manualSwitchToThirdReference ( 2420 ),
+ manualSwitchToFourthReference ( 2430 ),
+ manualSwitchToFifthReference ( 2440 ),
+ manualSwitchToSixthReference ( 2450 ),
+
+ manualSwitchBackToWorking ( 2460 ),
+ manualSwitchBackToWorkingRing ( 2470 ),
+ manualSwitchBackToWorkingSpan ( 2480 ),
+ manualSwitchToProtection ( 2490 ),
+ manualSwitchToProtectionRing ( 2500 ),
+ manualSwitchToProtectionSpan ( 2510 ),
+ manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath ( 2520 ),
+
+ powerfailRestart ( 2530 ),
+ ringIsSquelchingTraffic ( 2540 ),
+ softwareDownloadInProgress ( 2550 ),
+
+ switchToInternalClock ( 2560 ),
+ switchToPrimaryReference ( 2570 ),
+ switchToSecondReference ( 2580 ),
+ switchToThirdReference ( 2590 ),
+ switchToFourthReference ( 2600 ),
+ switchToFifthReference ( 2610 ),
+ switchToSixthReference ( 2620 ),
+
+ systemReboot ( 2630 ),
+ switchedBackToWorking ( 2640 ),
+ switchedToProtection ( 2650 ),
+ warmRestart ( 2660 ),
+ ringIsInWaitToRestoreState ( 2670 ),
+ manualSwitchRequest ( 2680 ),
+ forcedSwitchRequest ( 2690 ),
+ lockoutSwitchRequest ( 2700 ),
+
+ rmonHistoriesAndAlarmsResetReboot ( 2710 ),
+ rmonThresholdCrossingAlarm ( 2720 ),
+ alarmsSuppressedByUserCommand ( 2730 ),
+ alarmsSuppressedForMaintenance ( 2740 ),
+ switchingMatrixModuleFailure ( 2750 ),
+ lanConnectionPolarityReversed ( 2760 ),
+ autonomousPMReportMessageInhibited ( 2780 ),
+ ioSlotToXCONCommunicationFailure ( 2790 ),
+
+ -- Intentional gap
+
+ stsPathTraceIdentifierMismatch ( 2800 ),
+ nePowerFailureAtConnectorA ( 2810 ),
+ nePowerFailureAtConnectorB ( 2820 ),
+ freeMemoryOnCardVeryLow ( 2830 ),
+ freeMemoryOnCardNearZero ( 2840 ),
+
+ exerciseRequestOnRing ( 2850 ),
+ exerciseRequestOnSpan ( 2860 ),
+ squelchingPath ( 2870 ),
+ extraTrafficPreempted ( 2880 ),
+
+ farEndLockoutOfWorkingRing ( 2890 ),
+ farEndLockoutOfWorkingSpan ( 2900 ),
+ farEndLockoutOfProtectionRing ( 2910 ),
+ farEndLockoutOfProtectionAllSpans ( 2920 ),
+
+ farEndWorkingFacilityForcedToSwitchToProtectionRing ( 2930 ),
+ farEndWorkingFacilityForcedToSwitchToProtectionSpan ( 2940 ),
+
+ farEndManualSwitchOfWorkingFacilityToProtectionRing ( 2950 ),
+ farEndManualSwitchOfWorkingFacilityToProtectionSpan ( 2960 ),
+ farEndExercisingRing ( 2970 ),
+ farEndExercisingSpan ( 2980 ),
+ farEndBERThresholdPassedForSignalFailureRing ( 2990 ),
+ farEndBERThresholdPassedForSignalFailureSpan ( 3000 ),
+ farEndBERThresholdPassedForSignalDegradeRing ( 3010 ),
+ farEndBERThresholdPassedForSignalDegradeSpan ( 3020 ),
+ apsChannelFarEndProtectionLineSignalDegrade ( 3030 ),
+
+ ringSwitchIsActiveOnTheEastSide ( 3040 ),
+ ringSwitchIsActiveOnTheWestSide ( 3050 ),
+ spanSwitchIsActiveOnTheEastSide ( 3060 ),
+ spanSwitchIsActiveOnTheWestSide ( 3070 ),
+
+ uniDirectionalFullPassThroughIsActive ( 3080 ),
+ biDirectionalFullPassThroughIsActive ( 3090 ),
+
+ kBytesPassThroughIsActive ( 3100 ),
+ ringIsSegmented ( 3110 ),
+ ringTopologyIsUnderConstruction ( 3120 ),
+
+ lockoutOfProtectionAllSpans ( 3130 ),
+ farEndOfFiberIsProvisionedWithDifferentRingID ( 3140 ),
+ bothEndsOfFiberProvisionedAsEastOrBothAsWest ( 3150 ),
+ securityInvalidLoginUsernameSeeAuditTrail ( 3160 ),
+
+ autonomousMessagesInhibited ( 3170 ),
+ trafficStormOnLANLANTemporarilyDisabled ( 3180 ),
+
+ reptdbchgMessagesInhibited ( 3190 ),
+ securityUserIDHasExpired ( 3200 ),
+ partialFanFailure ( 3210 ),
+ forcedSwitchRequestOnRing ( 3220 ),
+ forcedSwitchRequestOnSpan ( 3230 ),
+ lockoutSwitchRequestOnRing ( 3240 ),
+ lockoutSwitchRequestOnSpan ( 3250 ),
+ manualSwitchRequestOnRing ( 3260 ),
+ manualSwitchRequestOnSpan ( 3270 ),
+
+ communicationFailurePeerToPeerSlotControlBusA ( 3280 ),
+ communicationFailurePeerToPeerSlotControlBusB ( 3290 ),
+ controllerAToShelfSlotCommunicationFailure ( 3300 ),
+ controllerBToShelfSlotCommunicationFailure ( 3310 ),
+
+ interconnectionEquipmentFailureWorkingPayloadBus ( 3320 ),
+ interconnectionEquipmentFailureProtectPayloadBus ( 3330 ),
+ inhibitSwitchToProtectRequestOnEquipment ( 3340 ),
+ inhibitSwitchToWorkingRequestOnEquipment ( 3350 ),
+
+ berThresholdExceededForSignalDegradeLine ( 3360 ),
+ berThresholdExceededForSignalDegradePath ( 3370 ),
+ berThresholdExceededForSignalFailureLine ( 3380 ),
+ berThresholdExceededForSignalFailurePath ( 3390 ),
+
+ exercisingRingSuccessfully ( 3400 ),
+ exercisingSpanSuccessfully ( 3410 ),
+ spanIsInWaitToRestoreState ( 3420 ),
+
+ exerciseRequestOnRingFailed ( 3430 ),
+ exerciseRequestOnSpanFailed ( 3440 ),
+ farEndLockoutOfProtectionSpan ( 3450 ),
+
+ manufacturingDataMemoryEEPROMFailure ( 3460 ),
+ replaceableEquipmentOrUnitIsMissing ( 3470 ),
+ softwareDownloadFailed ( 3480 ),
+ extraTrafficPCADropped ( 3490 ),
+
+ etherTxOversubscribed ( 3500 ),
+ etherRxOverSubscribed ( 3510 ),
+ etherTxExcessFlowCtrl ( 3520 ),
+ etherRxExcessFlowCtrl ( 3530 ),
+ transportLayerFailure ( 3540 ),
+ etherTxUnderrun ( 3550 ),
+
+ synchronizationReferenceFrequencyOutOfBounds ( 3560 ),
+ ntpOrSntpHostFailure ( 3570 ),
+ peerCardNotResponding ( 3580 ),
+ alarmsAndEventsSuppressedForThisObject ( 3590 ),
+ ds3FrameFormatMismatch ( 3600 ),
+
+ waitToRestore ( 3610 ),
+ extremeHighVoltBatteryA ( 3620 ),
+ extremeLowVoltBatteryA ( 3630 ),
+ extremeHighVoltBatteryB ( 3640 ),
+ extremeLowVoltBatteryB ( 3650 ),
+ iosConfigCopyFailed ( 3660 ),
+ iosConfigCopyInProgress ( 3670 ),
+ iosConfigCopySuccess ( 3680 ),
+
+ -- 3660 through 3700 reserverd for R3.3.x releases
+
+ signalingUnableToSetupCircuit ( 3710 ),
+ errorInStartupConfig ( 3712 ),
+ noStartupConfig ( 3714 ),
+ needToSaveRunningConfig ( 3716 ),
+ invalidAlarm ( 3718 ),
+ rsvpHelloFSMToNeighborDown ( 3720 ),
+ securityInvalidLoginUsername ( 3722 ),
+ databaseBackupFailed ( 3724 ),
+ databaseRestoreFailed ( 3726 ),
+ lmpHelloFSMToControlChannelDown ( 3730 ),
+ lmpNeighborDiscoveryHasFailed ( 3740 ),
+ unauthorizedIncomingSignalingRequest ( 3750 ),
+ auditLog80PercentFull ( 3760 ),
+ moduleCommunicationFailure ( 3762 ),
+ auditLog100PercentFullOldestRecordsWillBeLost ( 3764 ),
+ standbyDatabaseOutOfSync ( 3766 ),
+ redundantPowerCapabilityLost ( 3768 ),
+ forcedSwitchToPrimaryReference ( 3770 ),
+ forcedSwitchToSecondReference ( 3780 ),
+ forcedSwitchToThirdReference ( 3790 ),
+ forcedSwitchToInternalClock ( 3800 ),
+ industrialHighTemperature ( 3805 ),
+
+ timSectionTraceIdentifierMismatchFailure ( 4000 ),
+ aisMultiplexSectionAlarmIndicationSignal ( 4010 ),
+ rdiMultiplexSectionRemoteDefectOrAlarmIndication ( 4020 ),
+ timHighOrderTraceIdentifierMismatchFailure ( 4030 ),
+ aisAdministrationUnitAlarmIndicationSignal ( 4040 ),
+ lopAdministrationUnitLossOfPointer ( 4050 ),
+ slmfUnequippedHighOrderPathUnequipped ( 4060 ),
+ slmfPLMHighOrderPathLabelMismatch ( 4070 ),
+ rdiHighOrderRemoteDefectOrAlarmIndication ( 4080 ),
+ lopTributaryUnitLossOfPointer ( 4090 ),
+ aisTributaryUnitAlarmIndicationSignal ( 4100 ),
+ slmfUnequippedLowOrderPathUnequipped ( 4110 ),
+ slmfPLMLowOrderPathLabelMismatch ( 4120 ),
+ timLowOrderTraceIdentifierMismatchFailure ( 4130 ),
+ rfiLowOrderRemoteFailureOrAlarmIndication ( 4140 ),
+ g811PrimaryReferenceClockTraceable ( 4150 ),
+ g812TransitNodeClockTraceable ( 4160 ),
+ g812LocalNodeClockTraceable ( 4170 ),
+ g813SynchronousEquipmentTimingSourceTraceable ( 4180 ),
+ e1LoopbackDueToFEACCommand ( 4190 ),
+ e1LoopbackCommandSentToFarEnd ( 4200 ),
+ e3LoopbackDueToFEACCommand ( 4210 ),
+ farEndMultipleE1LOSDetectedOnE3 ( 4220 ),
+ farEndE1EqptFailNonServiceAffecting ( 4230 ),
+ farEndE1EqptFailServiceAffecting ( 4240 ),
+ farEndSingleE1LOS ( 4250 ),
+ farEndE3EqptFailServiceAffecting ( 4260 ),
+ e3LoopbackCommandSentToFarEnd ( 4270 ),
+ farEndE3EqptFailNonServiceAffecting ( 4280 ),
+ lowVoltBatteryA ( 4290 ),
+ highVoltBatteryA ( 4300 ),
+ lowVoltBatteryB ( 4310 ),
+ highVoltBatteryB ( 4320 ),
+ msspRingOutOfSync ( 4330 ),
+ msspMultiNodeTableUpdateCompleted ( 4340 ),
+ automaticSNCPSwitchCausedByAIS ( 4350 ),
+ automaticSNCPSwitchCausedByLOP ( 4360 ),
+ automaticSNCPSwitchCausedByUNEQ ( 4370 ),
+ automaticSNCPSwitchCausedByPDI ( 4380 ),
+ automaticSNCPSwitchCausedBySFBER ( 4390 ),
+ automaticSNCPSwitchCausedBySDBER ( 4400 ),
+ stmConcatenationError ( 4410 ),
+ e3IdleCondition ( 4420 ),
+ channelMSSPInconsistentAPSCode ( 4430 ),
+ channelMSSPImproperAPSCodeAPS ( 4440 ),
+ channelMSSPNodeIdMismatchAPS ( 4450 ),
+ channelMSSPDefaultKAPS ( 4460 ),
+ channelMSSPConnectionLossAPS ( 4470 ),
+ minimumClockTraceableSDH ( 4480 ),
+ lineIsInWaitToRestoreStateSDH ( 4490 ),
+ berThresholdExceededForSignalDegradeHighOrder ( 4500 ),
+ berThresholdExceededForSignalFailureHighOrder ( 4510 ),
+ berThresholdExceededForSignalDegradeLowOrder ( 4520 ),
+ berThresholdExceededForSignalFailureLowOrder ( 4530 ),
+ failureToSwitchToProtectionHighOrderPath ( 4540 ),
+ failureToSwitchToProtectionLowOrderPath ( 4550 ),
+ lofAdministrationUnitLossOfMultiFrame ( 4560 ),
+ sdhSpanIsInWaitToRestoreState ( 4570 ),
+ a8b10bOutOfSync ( 4755 ),
+ odukPMAlarmIndicationSignal ( 4760 ),
+ otukAlarmIndicationSignal ( 4765 ),
+ otukSMBackwardDefectIndication ( 4770 ),
+ fecUncorrectedWord ( 4780 ),
+ gccTerminationFailure ( 4785 ),
+ otukIncomingAlignmentError ( 4790 ),
+ odukLockedDefectPM ( 4795 ),
+ lossOfMultiFrame ( 4800 ),
+ odukOpenConnectionIndication ( 4805 ),
+ payloadTypeIdentifierMismatch ( 4810 ),
+ odukTrailTraceIdentifierMismatch ( 4815 ),
+ otukTrailTraceIdentifierMismatch ( 4820 ),
+ equipmentHighLaserBias ( 4825 ),
+ equipmentHighLaserTemp ( 4830 ),
+ equipmentHighLaserPeltier ( 4835 ),
+ facilityHighRxPower ( 4840 ),
+ equipmentHighTxPower ( 4845 ),
+ equipmentHighTransceiverVoltage ( 4850 ),
+ equipmentLowLaserBias ( 4855 ),
+ equipmentLowLaserTemp ( 4860 ),
+ equipmentLowLaserPeltier ( 4865 ),
+ facilityLowRxPower ( 4870 ),
+ equipmentLowTxPower ( 4875 ),
+ equipmentLowTransceiverVoltage ( 4880 ),
+ equipmentRxLocked ( 4885 ),
+ equipmentSquelched ( 4890 ),
+ equipmentTxLocked ( 4895 ),
+ otukSignalFailure ( 4900 ),
+ odukSignalFailure ( 4905 ),
+ otukSignalDegrade ( 4910 ),
+ odukSignalDegrade ( 4915 ),
+ pluggablePortMissing ( 4920 ),
+ pluggablePortRateMismatch ( 4925 ),
+ pluggablePortSecurityCodeMismatch ( 4930 ),
+ tciNotSelected ( 4935 ),
+ tci1ClockFailure ( 4940 ),
+ odukPMBackwardDefectIndication ( 4945 ),
+ odukTCM1BackwardDefectIndication ( 4950 ),
+ odukTCM2BackwardDefectIndication ( 4955 ),
+ equipmentHighRxTemperature ( 4960 ),
+ equipmentLowRxTemperature ( 4965 ),
+ tci2ClockFailure ( 4970 ),
+ equipmentWavelengthMismatch ( 4975 ),
+ dspCommunicationFailure ( 4980 ),
+ dspFailure ( 4985 ),
+ laserApproachingEndOfLife ( 5000 ),
+ crossconnectLoopback ( 5010 ),
+ adminLogoutOfUser ( 5020 ),
+ userLockedOut ( 5030 ),
+ adminLockoutOfUser ( 5040 ),
+ adminLockoutClear ( 5050 ),
+ invalidLoginUsername ( 5060 ),
+ securityInvalidLoginPassword ( 5070 ),
+ securityInvalidLoginLockedOut ( 5080 ),
+ securityInvalidLoginAlreadyLoggedOn ( 5090 ),
+ loginOfUser ( 5100 ),
+ automaticLogoutOfIdleUser ( 5110 ),
+ logoutOfUser ( 5120 ),
+ enhancedRemoteFailureIndicationPathServer ( 5200 ),
+ enhancedRemoteFailureIndicationPathConnectivity ( 5210 ),
+ enhancedRemoteFailureIndicationPathPayload ( 5220 ),
+ firewallHasBeenDisabled ( 5230 ),
+ securityIntrusionDetPwd ( 5240 ),
+ securityIntrusionDetUser ( 5250 ),
+ connectionEquipmentMismatch ( 5260 ),
+ disableInactiveUser ( 5270 ),
+ disableInactiveClear ( 5280 ),
+ batteryFailure ( 5290 ),
+ extremeHighVolt ( 5300 ),
+ extremeLowVolt ( 5310 ),
+ highVolt ( 5320 ),
+ lowVolt ( 5330 ),
+ suspendUser ( 5340 ),
+ suspendUserClear ( 5350 ),
+ lineDccTerminationFailure ( 5360 ),
+ multiplexSectionDccTerminationFailure ( 5370 ),
+ gigaBitEthernetOutOfSync ( 5380 ),
+ sequenceMismatch ( 5390 ),
+ lossOfAlignment ( 5400 ),
+ outOfUseByAdministrativeCommand ( 5410 ),
+ outOfUseTransportFailure ( 5420 ),
+ vcatGroupDown ( 5430 ),
+ vcatGroupDegraded ( 5440 ),
+ vcatGroupIncomplete ( 5450 ),
+ alarmIndicationSignalInTX ( 5460 ),
+ remoteAlarmIndicationInTX ( 5470 ),
+ kByteAPSChannelFailure ( 5480 ),
+ apsInvalidMode ( 5490 ),
+ ipAddressAlreadyInUseWithinTheSameDccArea ( 5500 ),
+ nodeNameInUseWithinTheSameDccArea ( 5510 ),
+ rearPanelEthernetLinkRemoved ( 5520 ),
+ manualSwitchToProtectResultedInNoTrafficSwitch ( 5530 ),
+ manualSwitchBackToWorkingResultedInNoTrafficSwitch ( 5540 ),
+ forcedSwitchToProtectResultedInNoTrafficSwitch ( 5550 ),
+ forcedSwitchBackToWorkingResultedInNoTrafficSwitch ( 5560 ),
+ duplicateSerialNumberDetectedOnAPluggableEntity ( 5570 ),
+ lossOfSignalForOpticalChannel ( 5600 ),
+ encapsulationMismatchPath ( 5610 ),
+ encapsulationMismatchVT ( 5620 ),
+ encapsulationMismatchHighOrderPath ( 5630 ),
+ encapsulationMismatchLowOrderPath ( 5640 ),
+ gfpUserPayloadMismatch ( 5650 ),
+ gfpFibreChannelDistanceExtensionMismatch ( 5660 ),
+ gfpFibreChannelDistanceExtensionBufferStarvation ( 5670 ),
+ gfpFibreChannelDistanceExtensionCreditStarvation ( 5680 ),
+ automaticWdmAnsFinished ( 5690 ),
+ gfpClientSignalFailDetected ( 5700 ),
+ gfpLossOfFrameDelineation ( 5710 ),
+ gfpExtensionHeaderMismatch ( 5730 ),
+ incomingOverheadSignalAbsent ( 5740 ),
+ opticalSafetyRemoteInterlockOn ( 5750 ),
+ automaticPowerControlCorrectionSkipped ( 5770 ),
+ apcCannotSetValueDueToRangeLimits ( 5780 ),
+ lcasVcgMemberTxSideInAddState ( 5790 ),
+ farEndManualSwitchBackToWorkingSpan ( 5800 ),
+ farEndForcedSwitchBackToWorkingSpan ( 5810 ),
+ universalTransponderModuleHardwareFailure ( 5820 ),
+ universalTransponderModuleCommunicationFailure ( 5830 ),
+ pluginModuleRangeSettingsMismatch ( 5840 ),
+ lcasVcgMemberTxSideInDnuState ( 5850 ),
+ lcasControlWordCrcCheckFailure ( 5860 ),
+ lcasVcgMemberRxSideInFailState ( 5870 ),
+ signalLossOnDataInterface ( 5880 ),
+ synchronizationLossOnDataInterface ( 5890 ),
+ portFAIL ( 5900 ),
+ unreachablePortTargetPower ( 5910 ),
+ portAddPowerDegradeLow ( 5920 ),
+ portAddPowerDegradeHigh ( 5930 ),
+ portAddPowerFailLow ( 5940 ),
+ portAddPowerFailHigh ( 5950 ),
+ automaticPowerControlTerminatedOnManualRequest ( 6000 ),
+ oduk1AlarmIndicationSignal ( 6010 ),
+ oduk2AlarmIndicationSignal ( 6020 ),
+ oduk3AlarmIndicationSignal ( 6030 ),
+ oduk4AlarmIndicationSignal ( 6040 ),
+ temperatureReadingMismatchBetweenSCCards ( 6050 ),
+ voltageReadingMismatchBetweenSCCards ( 6060 ),
+ alarmsSuppressedonOutOfGroupVcatMember ( 6070 ),
+ blsrSoftwareVersionMismatch ( 6080 ),
+ optimized1Plus1ApsPrimaryFacility ( 6090 ),
+ optimized1Plus1ApsPrimarySectionMismatch ( 6100 ),
+ optimized1Plus1ApsInvalidPrimarySection ( 6110 ),
+ compositeClockHighLineVoltage ( 6120 ),
+ berThresholdExceededForSignalDegradeVt ( 6130 ),
+ berThresholdExceededForSignalFailureVt ( 6140 ),
+ spanLengthOutOfRange ( 6150 ),
+ idleSignalCondition ( 6170 ),
+ idleSignalConditionInTx ( 6180 ),
+ vtPathTraceIdentifierMismatch ( 6190 ),
+ lossOfFrameInTX ( 6200 ),
+ provisioningMismatch ( 6210 ),
+ sectionTraceIdentifierMismatch ( 6220 ),
+ regeneratorSectionTraceIdentifierMismatch ( 6230 ),
+ switchingMatrixModuleFailureWorking ( 6240 ),
+ switchingMatrixModuleFailureProtect ( 6250 ),
+ slotCommunicationDisabled ( 6260 ),
+ sessionTimeLimitExpired ( 6270 ),
+ userPasswordChangeRequired ( 6280 ),
+ isisAdjacencyFailure ( 6290 ),
+ msspSoftwareVersionMismatch ( 6300 ),
+ remoteAuthenticationFailSeeAuditLog ( 6310 ),
+ ringIsSquelchingStsTraffic ( 6330 ),
+ ringIsSquelchingVtTraffic ( 6340 ),
+ archiveOfAuditLogFailed ( 6350 ),
+ rprWrapped ( 6360 ),
+ shelfCommunicationFailure ( 6370 ),
+ duplicatedShelfIdentifier ( 6380 ),
+ softwareMismatch ( 6390 ),
+ lmpFailure ( 6400 ),
+ opticalTerminationIncomplete ( 6410 ),
+ forwardDefectIndication ( 6420 ),
+ payloadMissingIndication ( 6430 ),
+ spanMeasurementCannotBePerformed ( 6440 ),
+ ringIsSquelchingHighOrderTraffic ( 6450 ),
+ ringIsSquelchingLowOrderTraffic ( 6460 ),
+ badPacketCountExceedsThreshold ( 6470 ),
+ linkLayerKeepAliveFailure ( 6480 ),
+ autonegotiationRemoteFailureIndication ( 6490 ),
+ trailSignalFail ( 6500 ),
+ ds1LoopbackCommandSentToFarEnd ( 6510 ),
+ multiplexSectionSignalDegraded ( 6520 ),
+ multiplexSectionExcessiveErrors ( 6530 ),
+ highOrderPathSignalDegraded ( 6540 ),
+ highOrderPathExcessiveErrors ( 6550 ),
+ lowOrderPathSignalDegraded ( 6560 ),
+ lowOrderPathExcessiveErrors ( 6570 ),
+ regeneratorSectionDccTerminationFailure ( 6580 ),
+ networkMemoryPoolLow ( 6590 ),
+ ospfRoutingTableOverflow ( 6600 ),
+ autoLaserShutdownDisabled ( 6610 ),
+ rprProtectionIsActive ( 6630 ),
+ maxRPRStationNumberExceeded ( 6640 ),
+ rprProtectionConfigurationMismatched ( 6650 ),
+ reservedBandwidthLinkRateExceededOnRinglet0 ( 6660 ),
+ reservedBandwidthLinkRateExceededOnRinglet1 ( 6670 ),
+ rprInterfaceInPassThroughMode ( 6680 ),
+ rprPeerNodeIsMissing ( 6690 ),
+ rprRiFailure ( 6700 ),
+ rprSignalFailure ( 6710 ),
+ rprSignalDegrade ( 6720 ),
+ interlinkFailure ( 6730 ),
+ apcWrongGain ( 6740 ),
+ rprSpanMismatch ( 6750 ),
+ efmRemoteFaultIndicationCriticalEvent ( 6760 ),
+ efmRemoteFaultIndicationDyingGasp ( 6770 ),
+ efmRemoteFaultIndicationLinkFault ( 6780 ),
+ efmLinkMonitoringErroredSymbolPeriodEvent ( 6790 ),
+ efmLinkMonitoringErroredFrameEvent ( 6800 ),
+ efmLinkMonitoringErroredFramePeriodEvent ( 6810 ),
+ efmLinkMonitoringErroredFrameSecondsSummary ( 6820 ),
+ efmRemoteLoopbackRequestFailed ( 6830 ),
+ fastAutomaticProtectionSwitching ( 6840 ),
+ fastAutomaticProtectionSwitchingConfigMismatch ( 6850 ),
+ lcasSinkGroupError ( 6860 ),
+ lcasVcgMemberRxSideInDnuState ( 6870 ),
+ fcDistanceExtFuncNotEstablished ( 6880 ),
+ nonCiscoPPMInserted ( 6890 ),
+ unqualifiedPPMInserted ( 6900 ),
+ ftaMismatch ( 6910 ),
+ cardPortsUnableToProvideProtection ( 6920 ),
+ lmpSignalDegrade ( 6930 ),
+ lmpSignalFailure ( 6940 ),
+ lmpUnallocatedDataLink ( 6950 ),
+ frontPortLinkLoss ( 6960 ),
+ bertEnbl ( 6970 ),
+ bertSyncFail ( 6975 ),
+ workQueueFull ( 6980 ),
+ equipmentPowerFailureAtConnectorA ( 7000 ),
+ equipmentPowerFailureAtConnectorB ( 7005 ),
+ equipmentPowerFailureAtReturnConnectorA ( 7010 ),
+ equipmentPowerFailureAtReturnConnectorB ( 7015 ),
+ bridgeAndRollHasOccurred ( 7055 ),
+ bridgeAndRollIsPendingAValidSignal ( 7060 ),
+ clockBusFailureTscA ( 7160 ),
+ clockBusFailureTscB ( 7165 ),
+ ospfHelloFail ( 7185 ),
+ openIOSlots ( 7200 ),
+ lossOfClockFromMateShelfController ( 7210 ),
+ virtualLanAlarmIndiacationSignal ( 7225 ),
+ dcuLossFailure ( 7230 ),
+ ochncMaintenance ( 7235 ),
+ ramanLaserShutdown ( 7240 ),
+ losOfRamanSignal ( 7245 ),
+ mcastMacTableFull ( 7250 ),
+ multicastMacAddressAliasing ( 7255 ),
+ ramanPwrProtOn ( 7260 ),
+ cppPeerNotResponding ( 7265 ),
+ voaControlLoopDisableDueToExcessiveCounterPropagationLight ( 7275 ),
+ wizardIsRunning ( 7280 ),
+ ramanGainNotReached ( 7285 ),
+ pprForwardDefectIndication ( 7295 ),
+ pprBackwardDefectIndication ( 7300 ),
+ pprCoordinatedMaintenance ( 7305 ),
+ pprTriggerThresholdBerExceeded ( 7310 ),
+ localFault ( 7315 ),
+ remoteFault ( 7320 ),
+ efmRemoteLoopbackConfigured ( 7325 ),
+ efmPeerMissing ( 7330 ),
+ eqptDegrade ( 7335 ),
+ excessiveBackPropagation ( 7340 ),
+ remoteMaintenanceEndPointIsDown ( 7345 ),
+ crossConnectedCFMService ( 7350 ),
+ cfmLoop ( 7355 ),
+ cfmConfigurationError ( 7360 ),
+ outOfChannelGroupBundle ( 7365 ),
+ repNeighborAdjacencyFailure ( 7370 ),
+ repLinkFlapping ( 7375 ),
+ faultInREPSegment ( 7380 ),
+ primaryREPEdgePortElected ( 7385 ),
+ secondaryREPEdgePortElected ( 7390 ),
+ stcnREPGenerated ( 7395 ),
+ vlbREPActivated ( 7400 ),
+ vlbREPTriggerSoakingDelayActive ( 7405 ),
+ wanSyncloss ( 7410 ),
+ laserShutdownDueToWavelengthDrift ( 7415 ),
+ manualLaserRestart ( 7420 ),
+ laserShutdownDueToNonCiscoPPMInserted ( 7425 ),
+ ethernetOSCTerminationFailure ( 7430 ),
+ softwareSignatureVerificationFailed ( 7445 ),
+ protectVolumeSoftwareSignatureVerificationFailed ( 7450 ),
+ activeVolumeSoftwareSignatureVerificationFailed ( 7455 ),
+ peerPortClientSignalFailDetected (7460),
+ channelShutdownDueToWavelengthDrift ( 7465 ),
+ usbWriteFailure ( 7475 ),
+ usbSyncInProgress ( 7480 ),
+ autoSensingUnableToDetectValidPayload (7485),
+ payloadAutoSensingInProgress (7490),
+ gfpClientSignalFailDetectedDueToSigloss (7495),
+ gfpClientSignalFailDetectedDueToSyncloss (7500),
+ pmdDegrade (7510),
+ standbyTccNEClockIsInternalClock ( 7515 ),
+ chromaticDispersionValue ( 7520 ),
+ packetTransportServiceFailed ( 7525 ),
+ satellitePanelDiscoveryFailure ( 7530 ),
+ satellitePanelActiveLinkFailure ( 7535 ),
+ satellitePanelCommunicationFailure ( 7540 ),
+ satellitePanelImproperConfiguration ( 7545 ),
+ satellitePanelFanMismatchOfEquipmentAndAttributes ( 7550 ),
+ satellitePanelFanFailure ( 7555 ),
+ satellitePanelPartialFanFailure ( 7560 ),
+ satellitePanelFANManufacturingDataMemoryEEPROMFailure ( 7565 ),
+ satellitePanelFANUnitIsMissing ( 7570 ),
+ satellitePanelIndustrialHighTemperature ( 7575 ),
+ satellitePanelHighTemperature ( 7580 ),
+ satellitePanelBatteryFailureA ( 7585 ),
+ plannedSwitchOver ( 7590 ),
+ protectionCardConfigurationMismatch ( 7595 ),
+ routerProcessorSwitchOver ( 7600 ),
+ runningLowOnResources ( 7605 ),
+ noMoreResourcesAreAvailable ( 7610 ),
+ esmcFailure ( 7615 ),
+ licenseWillExpireWithin24Hours ( 7620 ),
+ licenseWillExpireAnytimeAfter1DayButBefore14Days ( 7625 ),
+ licenseIsExpired ( 7630 ),
+ licenseCountViolation ( 7635 ),
+ temporaryLicenseIsInUse ( 7640 ),
+ evaluationLicenseIsInUse ( 7645 ),
+ licenseIsMissing ( 7650 ),
+ pseudowireDown ( 7655 ),
+ workingPseudowireControlPlaneDown ( 7660 ),
+ protectPseudowireControlPlaneDown ( 7665 ),
+ workingPseudowireConnectivityCheckDown ( 7670 ),
+ protectPseudowireConnectivityCheckDown ( 7675 ),
+ pseudowireTrafficSwitchedToProtection ( 7680 ),
+ workingPseudowireLocalAcTxPortFault ( 7685 ),
+ protectPseudowireLocalAcTxPortFault ( 7690 ),
+ workingPseudowireLocalAcRxPortFault ( 7695 ),
+ protectPseudowireLocalAcRxPortFault ( 7700 ),
+ workingPseudowireRemoteAcTxPortFault ( 7705 ),
+ protectPseudowireRemoteAcTxPortFault ( 7710 ),
+ workingPseudowireRemoteAcRxPortFault ( 7715 ),
+ protectPseudowireRemoteAcRxPortFault ( 7720 ),
+ slaThresholdCrossAlert ( 7725 ),
+ protectLocalPseudowireNotForwarding ( 7730 ),
+ workingPseudowireNotForwarding ( 7735 ),
+ protectPseudowireNotForwarding ( 7740 ),
+ tpTunnelDown ( 7745 ),
+ workingLabelSwitchedPathDown ( 7750 ),
+ protectLabelSwitchedPathDown ( 7755 ),
+ workingLabelSwitchedPathAlarmIndicationSignal ( 7760 ),
+ protectLabelSwitchedPathAlarmIndicationSignal ( 7765 ),
+ workingLabelSwitchedPathRemoteDefectIndication ( 7770 ),
+ protectLabelSwitchedPathRemoteDefectIndication ( 7775 ),
+ bidirectionalForwardDetectionDown ( 7780 ),
+ tpTrafficSwitchedFromWorkingToProtection ( 7785 ),
+ workingTpLockout ( 7790 ),
+ protectTpLockout ( 7795 ),
+ ethernetFlowPointFailed ( 7800 ),
+ teTunnelDown ( 7805 ),
+ macSystemLimitReached ( 7810 ),
+ macBridgeDomainLimitReached ( 7815 ),
+ autoSensingDisabled ( 7820 ),
+ smBackwardIncomingAlignmentError ( 7825 ),
+ resourceAllocationFailed ( 7830 ),
+ lossOfDFBSignal ( 7835 ),
+ workingLabelSwitchedPathLinkDownIndication ( 7840 ),
+ protectLabelSwitchedPathLinkDownIndication ( 7845 ),
+ workingLabelSwitchedPathLockReport ( 7850 ),
+ protectLabelSwitchedPathLockReport ( 7855 ),
+ satellitePanelBatteryFailureB ( 7860 ),
+ highBitErrorRate (7865),
+ backPanelFacilityLoopback (7870),
+ backPanelTerminalLoopback (7875),
+ trunkPayloadTypeMismatch (7880),
+ invalidMuxponderConfiguration (7885),
+ coolingProfileMismatch (7890),
+ trunkOduAlarmIndicationSignal (7895),
+ companionCardMissing (7900),
+ controlPlaneUnverifiedClearedAlarmsPresent (7905),
+ powerConsumptionLimitHasCrossed (7910),
+ masterKeyExchangeFailed (7915),
+ unitHighTemperature (7930),
+ overTemperatureUnitProtected (7935),
+ seqMismatchCount (7945),
+ keyProgramOnAlteraFpgaFailed (7960),
+ duplicateNodeControllerDetected (7970),
+ restorationInProg (7975),
+ ramanPumpsCalibrationProcedureIsRunning (7980),
+ ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes (7985),
+ odukTCM1AlarmIndicationSignal ( 13100 ),
+ odukTCM2AlarmIndicationSignal ( 13105 ),
+ odukLockedDefectTCM1 ( 13110 ),
+ odukLockedDefectTCM2 ( 13115 ),
+ otukLossOfFrame ( 13120 ),
+ odukOpenConnectionIndicationTCM1 ( 13125 ),
+ odukOpenConnectionIndicationTCM2 ( 13130 ),
+ odukTrailTraceIdentifierMismatchTCM1 ( 13135 ),
+ odukTrailTraceIdentifierMismatchTCM2 ( 13140 ),
+ odukSignalFailureTCM1 ( 13145 ),
+ odukSignalFailureTCM2 ( 13150 ),
+ odukSignalDegradeTCM1 ( 13155 ),
+ odukSignalDegradeTCM2 ( 13160 ),
+ lossOfChannel ( 13165 ),
+ fecMismatch ( 13170 ),
+ timSectionMonitorTraceIdentifierMismatchFailure ( 13175 ),
+ automaticLaserShutdown ( 13180 ),
+ shutterInsertionLossVariationDegradeLow ( 13200 ),
+ opticalChannelDeactivationFailure ( 13205 ),
+ shutterInsertionLossVariationDegradeHigh ( 13210 ),
+ networkTopologyIncomplete ( 13215 ),
+ pluginModuleCommunicationFailure ( 13220 ),
+ opticalNetworkTypeMismatch ( 13225 ),
+ opticalPowerDegradeLow ( 13230 ),
+ automaticPowerControlFailure ( 13235 ),
+ opticalPowerDegradeHigh ( 13240 ),
+ automaticPowerControlDisabled ( 13245 ),
+ opticalPowerFailureLow ( 13250 ),
+ ringIdMismatch ( 13255 ),
+ opticalPowerFailureHigh ( 13260 ),
+ lossOfContinuity ( 13270 ),
+ variableOpticalAttenuatorDegradeLow ( 13280 ),
+ variableOpticalAttenuatorDegradeHigh ( 13290 ),
+ variableOpticalAttenuatorFailureLow ( 13300 ),
+ variableOpticalAttenuatorFailureHigh ( 13310 ),
+ laserBiasDegrade ( 13320 ),
+ laserBiasFailure ( 13330 ),
+ laserTemperatureDegrade ( 13340 ),
+ opticalAmplifierGainDegradeLow ( 13350 ),
+ opticalAmplifierGainDegradeHigh ( 13360 ),
+ opticalAmplifierGainFailureLow ( 13370 ),
+ opticalAmplifierGainFailureHigh ( 13380 ),
+ opticalChannelConnectionFailure ( 13390 ),
+ opticalChannelIncomplete ( 13395 ),
+ opticalChannelActivationFailure ( 13400 ),
+ laserAutoPowerReduction ( 13410 ),
+ caseTemperatureDegrade ( 13420 ),
+ fiberTemperatureDegrade ( 13430 ),
+ shutterOpen ( 13440 ),
+ awgTemperatureDegrade ( 13450 ),
+ awgTemperatureFailure ( 13460 ),
+ awgOverTemperature ( 13470 ),
+ opticalAmplifierInitialization ( 13480 ),
+ awgWarmUp ( 13490 ),
+ incSigloss ( 13510 ),
+ incSyncloss ( 13515 ),
+ incGfpOutOfFrame ( 13520 ),
+ incGfpSigLoss ( 13525 ),
+ incGfpSyncLoss ( 13530 )
+}
+
+-- Cerent454ObjectType ::= TEXTUAL-CONVENTION
+-- DISPLAY-HINT "d"
+-- STATUS current
+-- DESCRIPTION
+-- "Very similar to the alarm type TC, except this is
+-- used for object type display"
+-- SYNTAX INTEGER {
+-- objectNone ( 1 ),
+-- objectEntity ( 10 ),
+-- objectInterface ( 20 ),
+-- objectOspf ( 30 ),
+-- objectProtectionGroup ( 40 ),
+-- objectSdccTerm ( 50 ),
+-- objectSync ( 60 ),
+-- objectSecurity ( 70 ),
+-- objectTopologyElement ( 80 ),
+-- objectSystem ( 90 ),
+-- objectStsConnection ( 100 ),
+-- objectVtConnection ( 110 ),
+-- objectSonetPool ( 120 ),
+-- objectEtherBridge ( 130 ),
+-- objectSpanningTree ( 140 ),
+-- objectVlan ( 150 ),
+-- objectCircuit ( 160 )
+-- }
+
+Cerent454EntityClass ::= TEXTUAL-CONVENTION
+ -- DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "This is the TC used to find out to which cerent454EntityClass
+ an alarm belongs to."
+ SYNTAX INTEGER {
+ unknownEntity ( 1 ),
+ ne ( 10 ),
+ backplane ( 30 ),
+ eqpt ( 50 ),
+ port ( 60 ),
+ ocn ( 70 ),
+ stmn ( 71 ),
+ aip ( 80 ),
+ fanTray ( 90 ),
+ crs ( 100 ),
+ ds3 ( 110 ),
+ almExpPanel ( 120 ),
+ almIfExtnsn ( 130 ),
+ stsMon ( 140 ),
+ vcMonHp ( 141 ),
+ dwdmClient ( 150 ),
+ stsTerm ( 160 ),
+ vcTermHp ( 161 ),
+ dwdmTrunk ( 170 ),
+ dwdmOptics ( 180 ),
+ psSts ( 190 ),
+ rsms ( 200 ),
+ xcSts ( 210 ),
+ bits ( 220 ),
+ dwdmFec ( 230 ),
+ neSynchRef ( 240 ),
+ dwdm8b10b ( 250 ),
+ extSynchRef ( 260 ),
+ dwdmOtn ( 270 ),
+ envAlrm ( 280 ),
+ envCtrl ( 290 ),
+ neRing ( 360 ),
+ ds1 ( 390 ),
+ vtMon ( 410 ),
+ vcMonLp ( 411 ),
+ vtTerm ( 420 ),
+ vcTermLP ( 421 ),
+ fUdc ( 430 ),
+ msUdc ( 440 ),
+ spareSdcc ( 450 ),
+ ucpCircuit ( 480 ),
+ ucpIpcc ( 490 ),
+ ucpNeighbor ( 500 ),
+ ec1 ( 510 ),
+ ps ( 520 ),
+ psVt ( 530 ),
+ e100t ( 540 ),
+ e1000t ( 550 ),
+ etherBridge ( 560 ),
+ e1 ( 600 ),
+ e3 ( 630 ),
+ e4 ( 640 ),
+ stm1E ( 650 ),
+ ds3i ( 660 ),
+ g1000 ( 670 ),
+ ml100t ( 680 ),
+ ml1000 ( 690 ),
+ dwdmSfp ( 700 ),
+ dwdmScl ( 710 ),
+ dwdmTcm1 ( 720 ),
+ dwdmTcm2 ( 730 ),
+ dwdmOcn ( 740 ),
+ dwdmSm ( 750 ),
+ dwdmPm ( 760 ),
+ dwdmTcm ( 770 ),
+ pwr ( 780 ),
+ stsTermVcat ( 790 ),
+ vtTermVcat ( 800 ),
+ vcatGroup ( 810 ),
+ fcmr ( 820 ),
+ entOptics ( 830 ),
+ ce100t ( 840 ),
+ ppm ( 850 ),
+ twor ( 860 ),
+ isc ( 870 ),
+ escon ( 880 ),
+ bic ( 890 ),
+ gfp ( 900 ),
+ gige ( 910 ),
+ pos ( 920 ),
+ cap ( 930 ),
+ dwdmData ( 940 ),
+ logFac ( 950 ),
+ ge ( 960 ),
+ fc ( 970 ),
+ ec1p1 ( 980 ),
+ mlFx ( 990 ),
+ ochTerm ( 1000 ),
+ shelf ( 1010 ),
+ ce1000 ( 1020 ),
+ cemr ( 1030 ),
+ lmp ( 1040 ),
+ lmpControlChannel ( 1050 ),
+ lmpTeLink ( 1060 ),
+ lmpDataLink ( 1070 ),
+ rpr ( 1080 ),
+ ether ( 1090 ),
+ mlmr ( 1100 ),
+ otu ( 1110 ),
+ aots ( 3200 ),
+ ots ( 3210 ),
+ oms ( 3220 ),
+ och ( 3230 ),
+ osc ( 3240 ),
+ ochnc ( 3250 ),
+ ib ( 3260 ),
+ chgrp ( 3270 ),
+ hdlc ( 3280 ),
+ msISC ( 3290 ),
+ ecu ( 3300 ),
+ lcdFlash ( 3310 ),
+ usb ( 3320 ),
+ fe ( 3330 ),
+ odu0 ( 3350 ),
+ odu1 ( 3360 )
+
+}
+
+-- **************************************************************
+cerent454Objects OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The cerent454 specific objects themselves"
+ ::= { cerent454Mib 20 }
+
+-- **************************************************************
+-- All Cisco OTBU generic objects definitions
+-- These will be available for all Cisco OTBU products. Hence
+-- they are defined once under generic category.
+
+cerent454CommonObjectsGroup OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The group to combine all the Cisco OTBU common
+ objects"
+ ::= { cerentCommonObjects 10 }
+
+cerent454EnableNotification OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether the system produces
+ notifications. A value=FALSE will prevent notifications
+ from being sent by this system."
+ DEFVAL { true }
+ ::= { cerent454CommonObjectsGroup 10 }
+
+cerent454NodeTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates current local time as reflected by
+ the Cisco OTBU equipment. The format this scalar is
+ YYYYMMDDhhmmss{S/D}. E.g.,
+ 20011103133453D means 1:34:53 PM PDT on 03/Nov/2001
+ 19990614095436S means 9:54:36 AM PST on 14/Jun/1999.
+ If the last octet is S then the time is standard time.
+ Otherwise it is D to indicate it is daylight saving
+ time, if applicable"
+ ::= { cerent454CommonObjectsGroup 20 }
+
+cerent454SentNotifications OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of v1+v2 notifications sent out
+ by the agent. Resets to zero after
+ cold/warm start."
+ ::= { cerent454CommonObjectsGroup 30 }
+
+cerent454LastChangeTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the time
+ a conceptual row is created or deleted
+ in cerent454AlarmTable "
+ ::= { cerent454CommonObjectsGroup 40 }
+
+cerent454MultishelfEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether the system is configured
+ in multi-shelf mode or single-shelf mode."
+ DEFVAL { false }
+ ::= { cerent454CommonObjectsGroup 50 }
+
+-- **************************************************************
+--
+cerent454GeneralGroup OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { cerent454Objects 20 }
+
+cerent454SoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the version of software that is
+ used in Cisco ONS 15454. E.g., 2.2.03"
+ ::= { cerent454GeneralGroup 10 }
+
+cerent454AlarmGroup OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The group that will represent all the
+ alarm info in the Cisco ONS 15454 node"
+ ::= { cerent454Objects 30 }
+
+cerent454AlarmCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of active alarms in Cisco ONS 15454.
+ This equals the total number of rows in
+ cerent454AlarmTable at any time."
+ ::= { cerent454AlarmGroup 10 }
+
+cerent454AlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cerent454AlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table has all currently raised conditions
+ for the network node. A Condition is a fault or
+ status detected by hardware or software."
+ ::= { cerent454AlarmGroup 20 }
+
+cerent454AlarmEntry OBJECT-TYPE
+ SYNTAX Cerent454AlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for cerent454AlarmTable"
+ INDEX { cerent454AlarmIndex, cerent454AlarmType }
+ ::= { cerent454AlarmTable 1 }
+
+Cerent454AlarmEntry ::= SEQUENCE {
+ cerent454AlarmIndex Integer32,
+ cerent454AlarmObjectType Cerent454EntityClass,
+ cerent454AlarmSlotNumber Integer32,
+ cerent454AlarmPortNumber CerentPortNumber,
+ cerent454AlarmLineNumber Integer32,
+ cerent454AlarmObjectIndex Integer32,
+ cerent454AlarmType Cerent454AlarmType,
+ cerent454AlarmState CerentNotificationClass,
+ cerent454AlarmTimeStamp TimeStamp,
+ cerent454AlarmObjectName DisplayString,
+ cerent454AlarmAdditionalInfo DisplayString,
+ cerent454AlarmSeverity CerentAlarmSeverity,
+ cerent454AlarmStatus CerentAlarmStatus,
+ cerent454AlarmServiceAffecting CerentAlarmServiceAffecting
+ }
+
+cerent454AlarmIndex OBJECT-TYPE
+ SYNTAX Integer32 ( 1..2147483647 ) -- all +ve values
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Identifies each entry in alarm table.
+ May not start with one and there may be some
+ missing numbers."
+ ::= { cerent454AlarmEntry 10 }
+
+cerent454AlarmObjectType OBJECT-TYPE
+ SYNTAX Cerent454EntityClass
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This will indicate what is the type
+ of the entity which raised this alarm.
+ ( E.g., DS3, etherBridge, VT-TERM, etc )
+ The NMS is expected to use this value
+ to decide which table to poll for
+ further info about the alarm"
+ ::= { cerent454AlarmEntry 20 }
+
+cerent454AlarmSlotNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This will indicate what is the slot
+ of the object which raised this alarm.
+ If not relevant to the alarm, will be
+ zero."
+ ::= { cerent454AlarmEntry 30 }
+
+cerent454AlarmPortNumber OBJECT-TYPE
+ SYNTAX CerentPortNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This will indicate what is the port
+ of the object which raised this alarm."
+ ::= { cerent454AlarmEntry 40 }
+
+cerent454AlarmLineNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This will indicate what is the port
+ of the object which raised this alarm.
+ If not relevant to the alarm, will be
+ zero."
+ ::= { cerent454AlarmEntry 50 }
+
+cerent454AlarmObjectIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Every alarm is raised by an object and
+ this object is an entry in a specific
+ table. This is the index of the object
+ in that table E.g., if the alarm is interface
+ related, this index is the index of the
+ interface in the interface table."
+ ::= { cerent454AlarmEntry 60 }
+
+cerent454AlarmType OBJECT-TYPE
+ SYNTAX Cerent454AlarmType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates what the exact nature of the
+ alarm. See the Cerent454AlarmType TC
+ for mapping details "
+ ::= {cerent454AlarmEntry 70 }
+
+cerent454AlarmState OBJECT-TYPE
+ SYNTAX CerentNotificationClass
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies alarm severity and service
+ affecting status ( SA/NSA ). Only
+ {minor|major|critical}+{NA|NSA} alarms and
+ standing conditions will be represented here.
+
+ However, this mib object is included in each
+ trap dispatched and in the trap this object
+ can contain all the possible values of
+ CerentNotificationClass type."
+ ::= { cerent454AlarmEntry 80 }
+
+cerent454AlarmTimeStamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when this entry was
+ created. This is accurate only upto a second."
+ ::= { cerent454AlarmEntry 90 }
+
+cerent454AlarmObjectName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "TL1-style user-visible name which uniquely
+ identifies an object in the system"
+ ::= { cerent454AlarmEntry 100 }
+
+cerent454AlarmAdditionalInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Additional information for the alarm object.
+ In the current version of the MIB, this object
+ contains the following information :-
+
+ a) Provisioned description for alarms of type
+ 'failureDetectedExternalToTheNE'.
+
+ This object would be a null string if no
+ additional information is specified."
+ ::= { cerent454AlarmEntry 110 }
+
+cerent454AlarmSeverity OBJECT-TYPE
+ SYNTAX CerentAlarmSeverity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies severity of the alarm
+ being sent out."
+
+ ::= { cerent454AlarmEntry 120 }
+
+cerent454AlarmStatus OBJECT-TYPE
+ SYNTAX CerentAlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Represents if the alarm is currently raised
+ or cleared."
+
+ ::= { cerent454AlarmEntry 130 }
+
+cerent454AlarmServiceAffecting OBJECT-TYPE
+ SYNTAX CerentAlarmServiceAffecting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the alarm that is being
+ sent out is Service Affecting (SA) or Non-
+ Service Affecting (NSA)."
+
+ ::= { cerent454AlarmEntry 140 }
+
+
+cerent454ReportedAlarmCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of alarms currently reported against Cisco
+ ONS 15454. This equals the number of rows in
+ cerent454ReportedAlarmTable."
+ ::= { cerent454AlarmGroup 30 }
+
+
+cerent454ReportedAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cerent454ReportedAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table has the list of alarms currently
+ reported for the Cisco ONS node. It does not
+ include any cleared alarms. The alarms in this
+ table are in compliance with Telcordia GR-253.
+ This means that if a network problem causes two
+ alarms, such a as loss of frame(LOF) and loss of
+ signal(LOS), only LOS alarm will be in this table
+ because it supersedes and replaces the LOF."
+ ::= { cerent454AlarmGroup 40 }
+
+cerent454ReportedAlarmEntry OBJECT-TYPE
+ SYNTAX Cerent454ReportedAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for cerent454ReportedAlarmTable"
+ INDEX { cerent454ReportedAlarmIndex, cerent454ReportedAlarmType }
+ ::= { cerent454ReportedAlarmTable 1 }
+
+Cerent454ReportedAlarmEntry ::= SEQUENCE {
+ cerent454ReportedAlarmIndex Integer32,
+ cerent454ReportedAlarmObjectType Cerent454EntityClass,
+ cerent454ReportedAlarmSlotNumber Integer32,
+ cerent454ReportedAlarmPortNumber CerentPortNumber,
+ cerent454ReportedAlarmObjectIndex Integer32,
+ cerent454ReportedAlarmType Cerent454AlarmType,
+ cerent454ReportedAlarmTimeStamp TimeStamp,
+ cerent454ReportedAlarmObjectName DisplayString,
+ cerent454ReportedAlarmAdditionalInfo DisplayString,
+ cerent454ReportedAlarmSeverity CerentAlarmSeverity,
+ cerent454ReportedAlarmStatus CerentAlarmStatus,
+ cerent454ReportedAlarmServiceAffecting CerentAlarmServiceAffecting
+ }
+
+cerent454ReportedAlarmIndex OBJECT-TYPE
+ SYNTAX Integer32 ( 1..2147483647 ) -- all +ve values
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Identifies each entry in ReportedAlarm table.
+ May not start with one and there may be some
+ missing numbers."
+ ::= { cerent454ReportedAlarmEntry 10 }
+
+cerent454ReportedAlarmObjectType OBJECT-TYPE
+ SYNTAX Cerent454EntityClass
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This will indicate the type
+ of the entity which raised this alarm.
+ ( E.g., DS3, etherBridge, VT-TERM, etc )
+ The NMS is expected to use this value
+ to decide which table to poll for
+ further info about the alarm"
+ ::= { cerent454ReportedAlarmEntry 20 }
+
+cerent454ReportedAlarmSlotNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This will indicate what is the slot
+ of the object which raised this alarm.
+ If not relevant to the alarm, will be
+ zero."
+ ::= { cerent454ReportedAlarmEntry 30 }
+
+cerent454ReportedAlarmPortNumber OBJECT-TYPE
+ SYNTAX CerentPortNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This will indicate what is the port
+ of the object which raised this alarm."
+ ::= { cerent454ReportedAlarmEntry 40 }
+
+cerent454ReportedAlarmObjectIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Every alarm is raised by an object and
+ this object is an entry in a specific
+ table. This is the index of the object
+ in that table E.g., if the alarm is interface
+ related, this is the index of the
+ interface in the interface table."
+ ::= { cerent454ReportedAlarmEntry 50 }
+
+cerent454ReportedAlarmType OBJECT-TYPE
+ SYNTAX Cerent454AlarmType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the exact nature of the
+ alarm."
+ ::= {cerent454ReportedAlarmEntry 60 }
+
+cerent454ReportedAlarmTimeStamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when this entry was
+ created. This is accurate only upto a second."
+ ::= { cerent454ReportedAlarmEntry 70 }
+
+cerent454ReportedAlarmObjectName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "TL1-style user-visible name which uniquely
+ identifies an object in the system"
+ ::= { cerent454ReportedAlarmEntry 80 }
+
+cerent454ReportedAlarmAdditionalInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Additional information for the alarm object.
+ In the current version of the MIB, this object
+ contains the following information :-
+
+ a) Provisioned description for alarms of type
+ 'failureDetectedExternalToTheNE'.
+
+ This object would be a null string if no
+ additional information is specified."
+ ::= { cerent454ReportedAlarmEntry 90 }
+
+cerent454ReportedAlarmSeverity OBJECT-TYPE
+ SYNTAX CerentAlarmSeverity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies severity of the alarm."
+
+ ::= { cerent454ReportedAlarmEntry 100 }
+
+cerent454ReportedAlarmStatus OBJECT-TYPE
+ SYNTAX CerentAlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Represents if the alarm is currently raised
+ or cleared."
+
+ ::= { cerent454ReportedAlarmEntry 110 }
+
+cerent454ReportedAlarmServiceAffecting OBJECT-TYPE
+ SYNTAX CerentAlarmServiceAffecting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the alarm that is being
+ sent out is Service Affecting (SA) or Non-
+ Service Affecting (NSA)."
+
+ ::= { cerent454ReportedAlarmEntry 120 }
+
+
+-- All Cisco ONS 15454 Threshold definitions.
+
+cerent454ThresholdGroup OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The group that will represent all the
+ threshold info in the Cisco ONS 15454 node"
+ ::= { cerent454Objects 40 }
+
+cerent454ThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cerent454ThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table holds all the defined
+ Thresholds.
+
+ This table is currently unimplemented."
+
+ ::= { cerent454ThresholdGroup 10 }
+
+cerent454ThresholdEntry OBJECT-TYPE
+ SYNTAX Cerent454ThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for cerent454ThresholdTable"
+ INDEX { cerent454ThresholdIndex }
+ ::= { cerent454ThresholdTable 1 }
+
+Cerent454ThresholdEntry ::= SEQUENCE {
+ cerent454ThresholdIndex Integer32,
+ cerent454ThresholdMonitorType CerentMonitorType,
+ cerent454ThresholdLocation CerentLocation,
+ cerent454ThresholdPeriod CerentPeriod,
+ cerent454ThresholdSetValue Integer32,
+ cerent454ThresholdCurrentValue Integer32,
+ cerent454ThresholdDetectType INTEGER
+ }
+
+cerent454ThresholdIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647) -- Same as IfIndex from IF-MIB
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies each entry in Threshold table.
+ May not start with one and there will be some
+ missing numbers."
+ ::= { cerent454ThresholdEntry 10 }
+
+cerent454ThresholdMonitorType OBJECT-TYPE
+ SYNTAX CerentMonitorType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the type of metric monitored."
+ ::= { cerent454ThresholdEntry 20 }
+
+cerent454ThresholdLocation OBJECT-TYPE
+ SYNTAX CerentLocation
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This indicates if it near or far end"
+ ::= { cerent454ThresholdEntry 30 }
+
+cerent454ThresholdPeriod OBJECT-TYPE
+ SYNTAX CerentPeriod
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The sampling interval period is indicated here"
+ ::= { cerent454ThresholdEntry 40 }
+
+cerent454ThresholdSetValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object will be threshold that was
+ provisioned by the NMS"
+ ::= { cerent454ThresholdEntry 50 }
+
+-- TEXTUAL CONVENTION
+-- Description
+-- The value of the optical parameter that is being monitored.
+--
+-- The range of values varies depending on the type of optical
+-- parameter being monitored, as identified by a corresponding
+-- object with syntax OpticalParameterType.
+--
+-- when the optical parameter being monitored is 'power' or
+-- 'acpower', the supported range is from -1000 to 1000, in
+-- 1/10ths of dBm.
+-- Example: Actual power of -40 dbm is represented as -400.
+-- Actual power level of +30 dBm is represented as 300.
+--
+-- When the optical parameter being monitored is 'laserTemp' or
+-- 'apdTemp', the supported range is from -10000 to 30000, in
+-- 1/100ths of degrees centigrade.
+-- Example: A value of 2355 represents a temperature reading of
+-- 23.55 degrees C.
+--
+-- When the optical parameter being monitored is 'biasCurrent',
+-- the supported range is from 0 to 1000, in 1/10ths of
+-- percentage (%).
+-- Example: A value of 500 represents a bias current threshold
+-- of 50.0 %.
+--
+-- When the optical parameter being monitored is 'peltierCurrent',
+-- the supported range is from 0 to 10000, in milliamperes.
+--
+-- When the optical parameter being monitored is 'xcvrVoltage',
+-- the supported range is from 0 to 100000, in 1/10ths of
+-- millivolts.
+
+cerent454ThresholdCurrentValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current value of the counter which
+ measures the metric. This column will never be
+ implemented as the value of this object is already
+ accessible through IETF MIBs."
+ ::= { cerent454ThresholdEntry 60 }
+
+-- TEXTUAL CONVENTION
+-- Description
+-- The value of the optical parameter that is being monitored.
+--
+-- The range of values varies depending on the type of optical
+-- parameter being monitored, as identified by a corresponding
+-- object with syntax OpticalParameterType.
+--
+-- when the optical parameter being monitored is 'power' or
+-- 'acpower', the supported range is from -1000 to 1000, in
+-- 1/10ths of dBm.
+-- Example: Actual power of -40 dbm is represented as -400.
+-- Actual power level of +30 dBm is represented as 300.
+--
+-- When the optical parameter being monitored is 'laserTemp' or
+-- 'apdTemp', the supported range is from -10000 to 30000, in
+-- 1/100ths of degrees centigrade.
+-- Example: A value of 2355 represents a temperature reading of
+-- 23.55 degrees C.
+--
+-- When the optical parameter being monitored is 'biasCurrent',
+-- the supported range is from 0 to 1000, in 1/10ths of
+-- percentage (%).
+-- Example: A value of 500 represents a bias current threshold
+-- of 50.0 %.
+--
+-- When the optical parameter being monitored is 'peltierCurrent',
+-- the supported range is from 0 to 10000, in milliamperes.
+--
+-- When the optical parameter being monitored is 'xcvrVoltage',
+-- the supported range is from 0 to 100000, in 1/10ths of
+-- millivolts.
+
+
+cerent454ThresholdDetectType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ none(10),
+ mon(20),
+ term(30)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object will be the detect type for the
+ threshold."
+ ::= { cerent454ThresholdEntry 70 }
+
+
+-- All Cisco ONS 15454 Notifications definitions.
+
+cerent454Events OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Place holder for all notifications of Cisco ONS 15454"
+ ::= { cerent454Mib 30 }
+
+cerent454V2Events OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The sub-identifier has to be zero, as part
+ of the interoperability agreement between
+ SNMPv1 and SNMPv2 worlds."
+ ::= { cerent454Events 0 }
+
+-- ---------------------------------------------
+-- All the Cisco ONS 15454 notifications definitions
+-- ---------------------------------------------
+
+-- object and event groups
+
+alarmUnknown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "alarm unknown"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+
+ ::= { cerent454V2Events 1 }
+
+alarmCutoffIsInManualMode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "alarm cutoff is in manual mode"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 10 }
+
+failureDetectedExternalToTheNE
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmAdditionalInfo,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "failure detected External to the NE"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 20 }
+
+externalError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "external error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 30 }
+
+excessiveSwitching
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "excessive switching"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 40 }
+
+sdccTerminationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "SDCC Termination failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 50 }
+
+incomingFailureCondition
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "incoming failure condition"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 60 }
+
+alarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "alarm indication signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 70 }
+
+alarmIndicationSignalLine
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "alarm indication signal LINE"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 80 }
+
+alarmIndicationSignalPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "alarm indication signal Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 90 }
+
+alarmIndicationSignalVT
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "alarm indication signal VT"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 100 }
+
+apsChannelFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "APS Channel Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 110 }
+
+channelByteFailureAPS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel Byte failure APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 120 }
+
+channelProtectionSwitchingChannelMatchFailureAPS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel Protection Switching Channel Match failure APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 130 }
+
+channelAutomaticProtectionSwitchModeMismatchAPS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel Automatic Protection Switch Mode Mismatch APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 140 }
+
+farEndProtectionLineFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Far End Protection Line Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 150 }
+
+inconsistentAPSCode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Inconsistent APS code"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 160 }
+
+improperAPSCode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Improper APS code"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 170 }
+
+nodeIdMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Node Id Mismatch APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 180 }
+
+channelDefaultKAPS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel Default K APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 190 }
+
+connectionLoss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Connection loss APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 200 }
+
+bipolarViolation
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "bipolar Violation"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 210 }
+
+carrierLossOnTheLAN
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "carrier Loss on the LAN"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 220 }
+
+concatenationErrorSTS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "concatenation error STS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 230 }
+
+excessCollisionsOnTheLAN
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "excess collisions on the LAN"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 240 }
+
+facilityFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Facility Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 250 }
+
+farEndAIS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end AIS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 260 }
+
+farEndMultipleDS1LOSDetectedOnDS3
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end Multiple DS1 LOS detected on DS3"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 270 }
+
+farEndDS1EqptFailNonServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end DS1 eqpt fail non service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 280 }
+
+farEndDS1EqptFailServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end DS1 Eqpt fail service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 290 }
+
+farEndSingleDS1LOS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end Single DS1 LOS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 300 }
+
+farEndDS3EqptFailNonServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end DS3 Eqpt failure non service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 310 }
+
+farEndDS3EqptFailServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end DS3 Eqpt failure service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 320 }
+
+farEndCommonEquipmentFailureNonServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end common Eqpt failure non service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 330 }
+
+farEndIDLE
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end IDLE"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 340 }
+
+farEndLOS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end LOS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 350 }
+
+farEndLOF
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end LOF"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 360 }
+
+farEndBlockError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far End Block Error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 370 }
+
+ds3IdleCondition
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "idle Condition DS3"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 380 }
+
+lossOfFrame
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loss of Frame"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 390 }
+
+lossOfPointer
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loss of Pointer"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 400 }
+
+lossOfPointerPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loss of Pointer Path "
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 410 }
+
+lossOfPointerVT
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loss of Pointer VT"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 420 }
+
+lossOfSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loss of Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 430 }
+
+outOfFrame
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "out of Frame"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 440 }
+
+pathSelectorFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Path Selector Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 450 }
+
+remoteAlarmIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "remote Alarm Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 460 }
+
+remoteFailureIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "remote Failure Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 470 }
+
+remoteFailureIndicationLine
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "remote Failure Indication LINE"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 480 }
+
+remoteFailureIndicationPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "remote Failure Indication Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 490 }
+
+remoteFailureIndicationVT
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "remote Failure Indication VT"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 500 }
+
+signalDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "facility has passed BER Threshold for Signal Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 510 }
+
+severelyErroredFrame
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "severely Errored Frame"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 520 }
+
+signalFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "facility has passed BER threshold for Signal Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 530 }
+
+signalLabelMismatchFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "signal Label Mismatch Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 540 }
+
+payloadDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Payload Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 550 }
+
+payloadDefectIndicationPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Payload Defect Indication - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 560 }
+
+payloadLabelMismatchPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Payload Label Mismatch - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 570 }
+
+signalLabelMismatchFailurePayloadLabelMismatchVT
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "signal Label Mismatch Failure Payload Label Mismatch VT"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 580 }
+
+unequippedPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Unequipped - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 590 }
+
+signalLabelMismatchFailureUnequippedVT
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "signal Label Mismatch Failure Unequipped VT"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 600 }
+
+lossOfSynchronization
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Loss of Synchronization"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 610 }
+
+outOfSynchronization
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Out of Synchronization"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 620 }
+
+primarySynchronizationReferenceFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Primary Synchronization Reference Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 630 }
+
+secondarySynchronizationReferenceFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Secondary Synchronization Reference Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 640 }
+
+thirdSynchronizationReferenceFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Third Synchronization Reference Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 650 }
+
+fourthSynchronizationReferenceFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Fourth Synchronization Reference Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 660 }
+
+fifthSynchronizationReferenceFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Fifth Synchronization Reference Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 670 }
+
+sixthSynchronizationReferenceFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Sixth Synchronization Reference Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 680 }
+
+failedToReceiveSynchronizationStatusMessage
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "failed to receive Synchronization Status Message"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 690 }
+
+synchronizationStatusMessagesAreDisabledOnThisInterface
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "synchronization Status Messages are disabled on this
+interface"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 700 }
+
+stratum1PrimaryReferenceSourceTraceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Stratum1 Primary Reference Source Traceable"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 710 }
+
+synchronizedTraceabilityUnknown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "synchronized Traceability Unknown"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 720 }
+
+stratum2Traceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "stratum 2 Traceable "
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 730 }
+
+transitNodeClockTraceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "transit Node clock Traceable"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 740 }
+
+stratum3ETraceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "stratum 3E Traceable"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 750 }
+
+stratum3Traceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "stratum 3 Traceable"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 760 }
+
+sonetMinimumClockTraceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "SONET Minimum Clock Traceable"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 770 }
+
+stratum4Traceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "stratum 4 Traceable"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 780 }
+
+doNotUseForSynchronization
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "do not Use for Synchronization"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 790 }
+
+reservedForNetworkSynchronizationUse
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "reserved for Network Synchronization Use"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 800 }
+
+outgoingFailureCondition
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "outgoing failure condition"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 810 }
+
+remoteDefectIndicationLine
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "remote Defect Indication LINE"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 820 }
+
+remoteDefectIndicationPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "remote Defect Indication Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 830 }
+
+freeRunningSynchronizationMode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "free Running Synchronization mode"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 840 }
+
+holdoverSynchronizationMode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "holdover synchronization mode"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 850 }
+
+fastStartSynchronizationMode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "fast Start synchronization mode"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 860 }
+
+internalFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Internal Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 870 }
+
+internalError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Internal Error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 880 }
+
+internalMessageError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "internal Message Error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 890 }
+
+mismatchOfEquipmentAndAttributes
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "mismatch of Equipment and Attributes"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 900 }
+
+watchdogTimerTimeout
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "watchdog Timer Timeout"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 910 }
+
+softwareFaultOrFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "software Fault or failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 920 }
+
+softwareFaultDataIntegrityFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "software Fault - Data integrity fault :
+ The newly added provisioning or hardware has
+ caused the database to grow beyond its limit.
+ That is, the newly added object(s) in the system
+ has(have) enough memory to exist onboard but
+ too large to be saved in the database."
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 930 }
+
+programFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "program failure "
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 940 }
+
+controlEquipmentFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "control Equipment failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 950 }
+
+primaryNonVolatileBackupMemoryFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Primary Non-Volatile Backup Memory Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 960 }
+
+secondaryNonVolatileBackupMemoryFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Secondary Non-Volatile Backup Memory Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 970 }
+
+controlBusFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Control Bus Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 980 }
+
+controlBus1Failure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Control Bus 1 Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 990 }
+
+controlBus2Failure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Control Bus 2 Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1000 }
+
+tccAToShelfSlot1DROP1CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 1 (DROP 1) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1010 }
+
+tccAToShelfSlot2DROP2CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 2 (DROP 2) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1020 }
+
+tccAToShelfSlot3DROP3CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 3 (DROP 3) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1030 }
+
+tccAToShelfSlot4DROP4CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 4 (DROP 4) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1040 }
+
+tccAToShelfSlot5TRUNK1CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 5 (TRUNK 1) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1050 }
+
+tccAToShelfSlot6TRUNK2CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 6 (TRUNK 2) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1060 }
+
+tccAToShelfSlot7TCCACommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 7 (TCC A) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1070 }
+
+tccAToShelfSlot8XCONACommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 8 (XCON A) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1080 }
+
+tccAToShelfSlot9AICCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 9 (AIC) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1090 }
+
+tccAToShelfSlot10XCONBCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 10 (XCON B) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1100 }
+
+tccAToShelfSlot11TCCBCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 11 (TCC B) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1110 }
+
+tccAToShelfSlot12TRUNK3CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 12 (TRUNK 3) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1120 }
+
+tccAToShelfSlot13TRUNK4CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 13 (TRUNK 4) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1130 }
+
+tccAToShelfSlot14DROP5CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 14 (DROP 5) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1140 }
+
+tccAToShelfSlot15DROP6CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 15 (DROP 6) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1150 }
+
+tccAToShelfSlot16DROP7CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 16 (DROP 7) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1160 }
+
+tccAToShelfSlot17DROP8CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC A To Shelf Slot 17 (DROP 8) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1170 }
+
+tccAToDCCAProcessorCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "communication failure TCC A to DCC A processor"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1180 }
+
+tccBToShelfSlot1DROP1CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 1 (DROP 1) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1190 }
+
+tccBToShelfSlot2DROP2CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 2 (DROP 2) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1200 }
+
+tccBToShelfSlot3DROP3CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 3 (DROP 3) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1210 }
+
+tccBToShelfSlot4DROP4CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 4 (DROP 4) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1220 }
+
+tccBToShelfSlot5TRUNK1CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 5 (TRUNK 1) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1230 }
+
+tccBToShelfSlot6TRUNK2CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 6 (TRUNK 2) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1240 }
+
+tccBToShelfSlot7TCCACommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 7 (TCC A) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1250 }
+
+tccBToShelfSlot8XCONACommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 8 (XCON A) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1260 }
+
+tccBToShelfSlot9AICCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 9 (AIC) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1270 }
+
+tccBToShelfSlot10XCONBCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 10 (XCON B) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1280 }
+
+tccBToShelfSlot11TCCBCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 11 (TCC B) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1290 }
+
+tccBToShelfSlot12TRUNK3CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 12 (TRUNK 3) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1300 }
+
+tccBToShelfSlot13TRUNK4CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 13 (TRUNK 4) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1310 }
+
+tccBToShelfSlot14DROP5CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 14 (DROP 5) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1320 }
+
+tccBToShelfSlot15DROP6CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 15 (DROP 6) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1330 }
+
+tccBToShelfSlot16DROP7CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 16 (DROP 7) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1340 }
+
+tccBToShelfSlot17DROP8CommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To Shelf Slot 17 (DROP 8) Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1350 }
+
+tccBToDCCBProcessorCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TCC B To DCC B Processor Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1360 }
+
+controlEquipmentControlCommunicationsEquipmentFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "control Equipment Control Communications equipment failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1370 }
+
+controlProcessorFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Control Processor Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1380 }
+
+workingMemoryFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Working Memory Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1390 }
+
+interconnectionEquipmentFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "interconnection Equipment failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1400 }
+
+payloadBusFailureToIOSlot1XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 1 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1410 }
+
+payloadBusFailureToIOSlot2XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 2 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1420 }
+
+payloadBusFailureToIOSlot3XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 3 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1430 }
+
+payloadBusFailureToIOSlot4XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 4 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1440 }
+
+payloadBusFailureToIOSlot5XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 5 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1450 }
+
+payloadBusFailureToIOSlot6XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 6 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1460 }
+
+payloadBusFailureToIOSlot12XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 12 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1470 }
+
+payloadBusFailureToIOSlot13XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 13 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1480 }
+
+payloadBusFailureToIOSlot14XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 14 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1490 }
+
+payloadBusFailureToIOSlot15XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 15 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1500 }
+
+payloadBusFailureToIOSlot16XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 16 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1510 }
+
+payloadBusFailureToIOSlot17XCONSlot8
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 17 (XCON Slot 8)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1520 }
+
+payloadBusFailureToIOSlot1XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 1 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1530 }
+
+payloadBusFailureToIOSlot2XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 2 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1540 }
+
+payloadBusFailureToIOSlot3XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 3 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1550 }
+
+payloadBusFailureToIOSlot4XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 4 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1560 }
+
+payloadBusFailureToIOSlot5XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 5 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1570 }
+
+payloadBusFailureToIOSlot6XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 6 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1580 }
+
+payloadBusFailureToIOSlot12XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 12 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1590 }
+
+payloadBusFailureToIOSlot13XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 13 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1600 }
+
+payloadBusFailureToIOSlot14XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 14 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1610 }
+
+payloadBusFailureToIOSlot15XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 15 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1620 }
+
+payloadBusFailureToIOSlot16XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 16 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1630 }
+
+payloadBusFailureToIOSlot17XCONSlot10
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Payload Bus Failure To IO Slot 17 (XCON Slot 10)"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1640 }
+
+timeSlotInterchangeEquipmentFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Time Slot Interchange Equipment Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1650 }
+
+equipmentFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "equipment failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1660 }
+
+highTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "High Temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1670 }
+
+invalidMACAddress
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Invalid MAC Address"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1680 }
+
+boardFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Board Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1690 }
+
+diagnosticFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "equipment failure Diagnostics Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1700 }
+
+mediumAccessControlFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Medium Access Control Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1710 }
+
+facilityTerminationEquipmentFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "facility Termination equipment failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1720 }
+
+automaticLaserShutoffDueToHighTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Automatic Laser Shutoff Due To High Temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1730 }
+
+failureToReleaseFromProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "failure To Release from protection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1740 }
+
+receiverFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Receiver Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1750 }
+
+transmitFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Transmit Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1760 }
+
+facilityTerminationEquipmentReceiverMissing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "facility Termination equipment Receiver missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1770 }
+
+facilityTerminationEquipmentTransmitterMissing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "facility Termination equipment Transmitter missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1780 }
+
+failureToSwitchToProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "failure To Switch to protection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1790 }
+
+failureToSwitchToProtectionRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "failure To Switch to protection Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1800 }
+
+failureToSwitchToProtectionSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "failure To Switch to protection Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1810 }
+
+failureToSwitchToProtectionPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "failure to Switch to protection Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1820 }
+
+fanFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Fan Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1830 }
+
+equipmentUnitPlugIn
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "equipment unit plug in"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1840 }
+
+nePowerFailureAtConnector
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "NE Power Failure At Connector"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1850 }
+
+fuseAlarm
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Fuse Alarm"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1860 }
+
+synchronizationUnitFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "synchronization unit failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1870 }
+
+synchronizationSwitchingEquipmentFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "synchronization switching Equipment failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1880 }
+
+equipmentUnitUnplugged
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Equipment Unit Un-plugged"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1890 }
+
+loopback
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loop back"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1900 }
+
+ds1LoopbackDueToFEACCommand
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "DS1 Loopback Due To FEAC Command"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1910 }
+
+loopbackCommandSentToFarEndDS1
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loopback Command sent to Far End DS1"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1920 }
+
+ds3LoopbackDueToFEACCommand
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loopback due to FEAC command DS3"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1930 }
+
+ds3LoopbackCommandSentToFarEnd
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "DS3 Loopback Command Sent To Far End"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1940 }
+
+ds2LoopbackDueToFarEndCommand
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "DS2 Loopback Due To Far End Command"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1950 }
+
+ds2LoopbackCommandSentToFarEnd
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "DS2 Loopback Command Sent To Far End"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1960 }
+
+facilityLoopback
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Facility Loopback"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1970 }
+
+networkLoopback
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Network Loopback"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1980 }
+
+terminalLoopback
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Terminal Loopback"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 1990 }
+
+manuallyCausedAbnormalCondition
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "manually caused abnormal condition"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2000 }
+
+ethernetBridgeIsNewRootOfSpanningTree
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ethernet Bridge Is New Root Of Spanning Tree"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2010 }
+
+ethernetBridgeTopologyChange
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ethernet Bridge Topology Change"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2020 }
+
+normalCondition
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "normal condition"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2030 }
+
+embeddedOperationsChannelFailureLinkDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "embedded Operations Channel failure link down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2040 }
+
+peerStateMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "peer state mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2050 }
+
+proceduralError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "procedural Error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2060 }
+
+improperRemoval
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Improper Removal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2070 }
+
+duplicateNodeID
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Duplicate Node ID"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2080 }
+
+blsrOutOfSync
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "BLSR out of sync"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2090 }
+
+blsrMultiNodeTableUpdateCompleted
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "BLSR Multi-Node Table Update Completed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2100 }
+
+protectionUnitNotAvailable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "protection unit not available"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2110 }
+
+performanceMonitorThresholdCrossingAlert
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454ThresholdMonitorType,
+ cerent454ThresholdLocation,
+ cerent454ThresholdPeriod,
+ cerent454ThresholdSetValue,
+ cerent454ThresholdCurrentValue,
+ cerent454ThresholdDetectType,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "performance Monitor Threshold Crossing Alert"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2120 }
+
+protectionSwitch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Protection Switch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2130 }
+
+recoveryOrServiceProtectionActionHasBeenInitiated
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "recovery or service protection action has been initiated"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2140 }
+
+automaticSystemReset
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "automatic system Reset"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2150 }
+
+automaticUPSRSwitchCausedByAIS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "automatic UPSR switch caused by AIS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2160 }
+
+automaticUPSRSwitchCausedByLOP
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "automatic UPSR switch caused by Lop"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2170 }
+
+automaticUPSRSwitchCausedByUNEQ
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Automatic UPSR Switch Caused By UNEQ"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2180 }
+
+automaticUPSRSwitchCausedByPDI
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "automatic UPSR switch caused by PDI"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2190 }
+
+automaticUPSRSwitchCausedBySFBER
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Automatic UPSR Switch Caused By SFBER"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2200 }
+
+automaticUPSRSwitchCausedBySDBER
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Automatic UPSR Switch Caused By SDBER"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2210 }
+
+coldRestart
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "cold Restart"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2220 }
+
+forcedSwitchBackToWorking
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch Back To Working"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2230 }
+
+forcedSwitchBackToWorkingRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch Back To Working - Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2240 }
+
+forcedSwitchBackToWorkingSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch Back To Working - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2250 }
+
+forcedSwitchToProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch To Protection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2260 }
+
+forcedSwitchToProtectionRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch To Protection - Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2270 }
+
+forcedSwitchToProtectionSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch To Protection - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2280 }
+
+workingFacilityOrEquipmentForcedToSwitchToProtectionPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Working Facility or Equipment Forced To Switch To Protection - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2290 }
+
+initializationInitiated
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "initialization initiated"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2300 }
+
+lockoutOfProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "lockout of Protection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2310 }
+
+lockoutOfProtectionRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "lockout of Protection Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2320 }
+
+lockoutOfProtectionSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "lockout of Protection Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2330 }
+
+lockoutOfProtectionPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "lockout of Protection Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2340 }
+
+lockoutOfWorking
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "lockout of working"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2350 }
+
+lockoutOfWorkingRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "lockout of working Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2360 }
+
+lockoutOfWorkingSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "lockout of working Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2370 }
+
+manualSystemReset
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "manual system Reset"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2380 }
+
+manualSwitchToInternalClock
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch to Internal Clock"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2390 }
+
+manualSwitchToPrimaryReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch To Primary Reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2400 }
+
+manualSwitchToSecondReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch To Second Reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2410 }
+
+manualSwitchToThirdReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch To Third reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2420 }
+
+manualSwitchToFourthReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch To Fourth reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2430 }
+
+manualSwitchToFifthReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch To Fifth reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2440 }
+
+manualSwitchToSixthReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch To Sixth reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2450 }
+
+manualSwitchBackToWorking
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Manual Switch Back To Working"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2460 }
+
+manualSwitchBackToWorkingRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Manual Switch Back To Working - Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2470 }
+
+manualSwitchBackToWorkingSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Manual Switch Back To Working - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2480 }
+
+manualSwitchToProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Manual Switch To Protection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2490 }
+
+manualSwitchToProtectionRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Manual Switch To Protection - Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2500 }
+
+manualSwitchToProtectionSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Manual Switch To Protection - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2510 }
+
+manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Manual Switch Of Working Facility or Equipment To Protection - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2520 }
+
+powerfailRestart
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Powerfail Restart"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2530 }
+
+ringIsSquelchingTraffic
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ring is squelching traffic"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2540 }
+
+softwareDownloadInProgress
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "software download in progress"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2550 }
+
+switchToInternalClock
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switch To Internal clock"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2560 }
+
+switchToPrimaryReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switch To Primary refernce"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2570 }
+
+switchToSecondReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Switch To Second Reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2580 }
+
+switchToThirdReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switch To Third refernce"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2590 }
+
+switchToFourthReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switch To Fourth refernce"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2600 }
+
+switchToFifthReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switch To Fifth refernce"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2610 }
+
+switchToSixthReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switch To Sixth refernce"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2620 }
+
+systemReboot
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "system reboot"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2630 }
+
+switchedBackToWorking
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switched Back To Working"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2640 }
+
+switchedToProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switched To Protection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2650 }
+
+warmRestart
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "warm Restart"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2660 }
+
+ringIsInWaitToRestoreState
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ring is in Wait To Restore state"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2670 }
+
+manualSwitchRequest
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch Request"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2680 }
+
+forcedSwitchRequest
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Forced Switch Request"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2690 }
+
+lockoutSwitchRequest
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Lockout Switch Request"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2700 }
+
+rmonHistoriesAndAlarmsResetReboot
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "RMON Histories And Alarms Reset Reboot"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2710 }
+
+rmonThresholdCrossingAlarm
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Crossing of Falling/Rising Threshold detected"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2720 }
+
+alarmsSuppressedByUserCommand
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Alarms Suppressed By User Command"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2730 }
+
+alarmsSuppressedForMaintenance
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Alarms Suppressed For Maintenance"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2740 }
+
+switchingMatrixModuleFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switching Matrix Module Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2750 }
+
+lanConnectionPolarityReversed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Lan Connection Polarity Reversed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2760 }
+
+autonomousPMReportMessageInhibited
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Autonomous PM Report Message Inhibited"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2780 }
+
+ioSlotToXCONCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "IO Slot To XCON Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2790 }
+
+stsPathTraceIdentifierMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "STS Path Trace Identifier Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2800 }
+
+nePowerFailureAtConnectorA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "NE Power Failure At Connector A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2810 }
+
+nePowerFailureAtConnectorB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "NE Power Failure At Connector B"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2820 }
+
+freeMemoryOnCardVeryLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Free memory on the card is very low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2830 }
+
+freeMemoryOnCardNearZero
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Free memory on the card is near zero"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2840 }
+
+exerciseRequestOnRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Exercise Request on Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2850 }
+
+exerciseRequestOnSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Exercise Request on Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2860 }
+
+squelchingPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Squelching Path"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2870 }
+
+extraTrafficPreempted
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Extra Traffic Preempted."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2880 }
+
+farEndLockoutOfWorkingRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End Lockout of working - Ring."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2890 }
+
+farEndLockoutOfWorkingSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End Lockout of working - Span."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2900 }
+
+farEndLockoutOfProtectionRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End Lockout of Protection - Ring."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2910 }
+
+farEndLockoutOfProtectionAllSpans
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End Lockout of Protection - All Spans."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2920 }
+
+farEndWorkingFacilityForcedToSwitchToProtectionRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Far End Working Facility Forced To Switch To Protection - Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2930 }
+
+
+farEndWorkingFacilityForcedToSwitchToProtectionSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Far End Working Facility Forced To Switch To Protection - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2940 }
+
+farEndManualSwitchOfWorkingFacilityToProtectionRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Far End Manual Switch Of Working Facility To Protection - Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2950 }
+
+farEndManualSwitchOfWorkingFacilityToProtectionSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Far End Manual Switch Of Working Facility To Protection - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2960 }
+
+farEndExercisingRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Far End Exercising Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2970 }
+
+farEndExercisingSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Far End Exercising Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2980 }
+
+farEndBERThresholdPassedForSignalFailureRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End BER threshold passed for Signal Failure - Ring."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 2990 }
+
+farEndBERThresholdPassedForSignalFailureSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End BER threshold passed for Signal Failure - Span."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3000 }
+
+farEndBERThresholdPassedForSignalDegradeRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End BER threshold passed for Signal Degrade - Ring."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3010 }
+
+farEndBERThresholdPassedForSignalDegradeSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End BER threshold passed for Signal Degrade - Span."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3020 }
+
+apsChannelFarEndProtectionLineSignalDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "APS Channel - Far End Protection Line Signal Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3030 }
+
+ringSwitchIsActiveOnTheEastSide
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ring Switch is active on the East Side."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3040 }
+
+
+ringSwitchIsActiveOnTheWestSide
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ring Switch is active on the West Side."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3050 }
+
+spanSwitchIsActiveOnTheEastSide
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Span Switch is active on the East Side."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3060 }
+
+spanSwitchIsActiveOnTheWestSide
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Span Switch is active on the West Side."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3070 }
+
+uniDirectionalFullPassThroughIsActive
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Uni-directional Full Pass Through is active."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3080 }
+
+
+biDirectionalFullPassThroughIsActive
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Bi-directional Full Pass Through is active."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3090 }
+
+kBytesPassThroughIsActive
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "K Bytes Pass Through Is Active"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3100 }
+
+ringIsSegmented
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ring is Segmented."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3110 }
+
+ringTopologyIsUnderConstruction
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ring Topology is under construction."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3120 }
+
+lockoutOfProtectionAllSpans
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Lockout of Protection - All Spans."
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3130 }
+
+farEndOfFiberIsProvisionedWithDifferentRingID
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far end of fiber is provisioned with different ring ID"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3140 }
+
+bothEndsOfFiberProvisionedAsEastOrBothAsWest
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Both ends of fiber provisioned as East, or both as West"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3150 }
+
+securityInvalidLoginUsernameSeeAuditTrail
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS deprecated
+ DESCRIPTION "Security: invalid login (see Audit Trail)"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3160 }
+
+autonomousMessagesInhibited
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Autonomous messages inhibited"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3170 }
+
+trafficStormOnLANLANTemporarilyDisabled
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Traffic Storm On LAN. LAN Temporarily Disabled"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3180 }
+
+reptdbchgMessagesInhibited
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "REPT^DBCHG Messages Inhibited"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3190 }
+
+securityUserIDHasExpired
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Security: User ID Has Expired"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3200 }
+
+partialFanFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Partial Fan Failure"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3210 }
+
+forcedSwitchRequestOnRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch Request On Ring"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3220 }
+
+forcedSwitchRequestOnSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch Request On Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3230 }
+
+lockoutSwitchRequestOnRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Lockout switch request on Ring"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3240 }
+
+lockoutSwitchRequestOnSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Lockout switch request on Span"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3250 }
+
+manualSwitchRequestOnRing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual switch request on Ring"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3260 }
+
+manualSwitchRequestOnSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual switch request on Span"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3270 }
+
+communicationFailurePeerToPeerSlotControlBusA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Peer to Peer Slot communication failure - Control Bus A"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3280 }
+
+communicationFailurePeerToPeerSlotControlBusB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Peer to Peer Slot communication failure - Control Bus B"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3290 }
+
+controllerAToShelfSlotCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Controller A to shelf slot communication failure"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3300 }
+
+controllerBToShelfSlotCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Controller B to shelf slot communication failure"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3310 }
+
+interconnectionEquipmentFailureWorkingPayloadBus
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Interconnection Equipment Failure - Working Payload Bus"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3320 }
+
+interconnectionEquipmentFailureProtectPayloadBus
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Interconnection Equipment Failure - Protect Payload Bus"
+
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3330 }
+
+inhibitSwitchToProtectRequestOnEquipment
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Inhibit Switch to Protect Request on equipment"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3340 }
+
+inhibitSwitchToWorkingRequestOnEquipment
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Inhibit Switch to Working Request on equipment"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3350 }
+
+berThresholdExceededForSignalDegradeLine
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "BER Threshold exceeded for Signal Degrade - Line"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3360 }
+
+berThresholdExceededForSignalDegradePath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "BER Threshold exceeded for Signal Degrade - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3370 }
+
+berThresholdExceededForSignalFailureLine
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "BER Threshold Exceeded For Signal Failure - Line"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3380 }
+
+berThresholdExceededForSignalFailurePath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "BER Threshold Exceeded For Signal Failure - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3390 }
+
+exercisingRingSuccessfully
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Exercising Ring Successfully"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3400}
+
+exercisingSpanSuccessfully
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Exercising Span Successfully"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3410}
+
+spanIsInWaitToRestoreState
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Span is in Wait To Restore state"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3420 }
+
+exerciseRequestOnRingFailed
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Exercise Request on Ring Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3430 }
+
+exerciseRequestOnSpanFailed
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Exercise Request on Span Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3440 }
+
+farEndLockoutOfProtectionSpan
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Far End Lockout Of Protection - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3450 }
+
+manufacturingDataMemoryEEPROMFailure
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Manufacturing Data Memory (EEPROM) Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3460 }
+
+replaceableEquipmentOrUnitIsMissing
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Replaceable Equipment/Unit is Missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3470 }
+
+softwareDownloadFailed
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Software Download Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3480 }
+
+extraTrafficPCADropped
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Extra Traffic (PCA) Dropped"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3490 }
+
+etherTxOversubscribed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ether tx oversubscribed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3500 }
+
+etherRxOverSubscribed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ether rx over subscribed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3510 }
+
+etherTxExcessFlowCtrl
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ether tx excess flow ctrl"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3520 }
+
+etherRxExcessFlowCtrl
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ether rx excess flow ctrl"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3530 }
+
+transportLayerFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "transport layer failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3540 }
+
+etherTxUnderrun
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ether tx underrun"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3550 }
+
+synchronizationReferenceFrequencyOutOfBounds
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Synchronization reference frequency out of bounds."
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3560 }
+
+ntpOrSntpHostFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "NTP/SNTP Host Failure."
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3570 }
+
+peerCardNotResponding
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Peer Card Not Responding"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3580 }
+
+alarmsAndEventsSuppressedForThisObject
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Alarms and events suppressed for this object"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3590 }
+
+ds3FrameFormatMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "DS3 Frame Format Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3600 }
+
+waitToRestore
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Wait To Restore"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3610 }
+
+extremeHighVoltBatteryA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Extreme High Volt Battery A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3620 }
+
+extremeLowVoltBatteryA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Extreme Low Volt Battery A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3630 }
+
+extremeHighVoltBatteryB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Extreme High Volt Battery B"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3640 }
+
+extremeLowVoltBatteryB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Extreme Low Volt Battery B"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3650 }
+
+iosConfigCopyFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "IOS config copy failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3660 }
+
+iosConfigCopyInProgress
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "IOS config copy in progress"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3670 }
+
+iosConfigCopySuccess
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "IOS Config Copy Success"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3680 }
+
+-- Begin: UCP traps
+
+signalingUnableToSetupCircuit
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Signaling Unable to setup circuit"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3710 }
+
+errorInStartupConfig
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Error in Startup Config"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3712 }
+
+noStartupConfig
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "No Startup Config"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3714 }
+
+needToSaveRunningConfig
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Need to Save Running Config"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3716 }
+
+invalidAlarm
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Invalid Alarm"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3718 }
+
+rsvpHelloFSMToNeighborDown
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "RSVP Hello FSM to Neighbor down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3720 }
+
+securityInvalidLoginUsername
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Security: Invalid Login - Username - See Audit Log"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3722 }
+
+databaseBackupFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Database Backup Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3724 }
+
+databaseRestoreFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Database Restore Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3726 }
+
+lmpHelloFSMToControlChannelDown
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LMP Hello FSM to Control Channel down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3730 }
+
+lmpNeighborDiscoveryHasFailed
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LMP Neighbor Discovery has failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3740 }
+
+unauthorizedIncomingSignalingRequest
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Unauthorized incoming signaling request"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3750 }
+
+auditLog80PercentFull
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Audit Log 80 Percent Full"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3760 }
+
+moduleCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Module Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3762 }
+
+auditLog100PercentFullOldestRecordsWillBeLost
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Audit Log 100 Percent Full - Oldest records will be lost"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3764 }
+
+standbyDatabaseOutOfSync
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Standby Database Out of Sync"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3766 }
+
+redundantPowerCapabilityLost
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Redundant Power Capability Lost"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3768 }
+
+-- End: UCP traps
+
+forcedSwitchToPrimaryReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Forced Switch To Primary Reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3770 }
+
+forcedSwitchToSecondReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Forced Switch To Second Reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3780 }
+
+forcedSwitchToThirdReference
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Forced Switch To Third Reference"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3790 }
+
+forcedSwitchToInternalClock
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Forced Switch To Internal Clock"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3800 }
+
+industrialHighTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Industrial High Temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 3805 }
+
+
+-- Begin: SDH Traps
+
+timSectionTraceIdentifierMismatchFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "TIM Section - Trace Identifier Mismatch Failure."
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4000 }
+
+aisMultiplexSectionAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "AIS - Multiplex Section - Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4010 }
+
+rdiMultiplexSectionRemoteDefectOrAlarmIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "RDI - Multiplex Section - Remote Defect/Alarm Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4020 }
+
+timHighOrderTraceIdentifierMismatchFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TIM High Order - Trace Identifier Mismatch Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4030 }
+
+aisAdministrationUnitAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "AIS - Administration Unit - Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4040 }
+
+lopAdministrationUnitLossOfPointer
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LOP - Administration Unit - Loss of Pointer"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4050 }
+
+slmfUnequippedHighOrderPathUnequipped
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "SLMF - Unequipped High Order - Path Unequipped"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4060 }
+
+slmfPLMHighOrderPathLabelMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "SLMF - PLM High Order - Path Label Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4070 }
+
+rdiHighOrderRemoteDefectOrAlarmIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "RDI - High Order - Remote Defect/Alarm Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4080 }
+
+lopTributaryUnitLossOfPointer
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LOP - Tributary Unit - Loss of Pointer"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4090 }
+
+aisTributaryUnitAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "AIS - Tributary Unit - Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4100 }
+
+slmfUnequippedLowOrderPathUnequipped
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "SLMF - Unequipped Low Order - Path Unequipped"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4110 }
+
+slmfPLMLowOrderPathLabelMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "SLMF - PLM Low Order - Path Label Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4120 }
+
+timLowOrderTraceIdentifierMismatchFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "TIM Low Order - Trace Identifier Mismatch Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4130 }
+
+rfiLowOrderRemoteFailureOrAlarmIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "RFI - Low Order - Remote Failure/Alarm Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4140 }
+
+g811PrimaryReferenceClockTraceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "G811 - Primary Reference Clock traceable."
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4150 }
+
+g812TransitNodeClockTraceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "G812 - Transit Node Clock traceable."
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4160 }
+
+g812LocalNodeClockTraceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "G812 - Local Node Clock traceable."
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4170 }
+
+g813SynchronousEquipmentTimingSourceTraceable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "G813 - Synchronous Equipment Timing Source traceable"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4180 }
+
+e1LoopbackDueToFEACCommand
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "E1 loopback due to FEAC command"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4190 }
+
+e1LoopbackCommandSentToFarEnd
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "E1 loopback command sent to Far End"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4200 }
+
+e3LoopbackDueToFEACCommand
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "E3 loopback due to FEAC command"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4210 }
+
+farEndMultipleE1LOSDetectedOnE3
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end Multiple E1 LOS detected on E3"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4220 }
+
+farEndE1EqptFailNonServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end E1 eqpt fail non service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4230 }
+
+farEndE1EqptFailServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end E1 eqpt fail service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4240 }
+
+farEndSingleE1LOS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end Single E1 LOS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4250 }
+
+farEndE3EqptFailServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end E3 eqpt fail service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4260 }
+
+e3LoopbackCommandSentToFarEnd
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "E3 loopback command sent to far end"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4270 }
+
+farEndE3EqptFailNonServiceAffecting
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "far end E3 eqpt fail non service affecting"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4280 }
+
+lowVoltBatteryA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Low Volt - Battery A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4290 }
+
+highVoltBatteryA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "High Volt - Battery A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4300 }
+
+lowVoltBatteryB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Low Volt - Battery B"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4310 }
+
+highVoltBatteryB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "High Volt - Battery B"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4320 }
+
+msspRingOutOfSync
+NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "MS-SP ring out of sync"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4330 }
+
+msspMultiNodeTableUpdateCompleted
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "MSSP Multi-Node Table Update Completed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4340 }
+
+automaticSNCPSwitchCausedByAIS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "automatic SNCP switch caused by AIS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4350 }
+
+automaticSNCPSwitchCausedByLOP
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "automatic SNCP switch caused by Lop"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4360 }
+
+automaticSNCPSwitchCausedByUNEQ
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Automatic SNCP Switch caused by UNEQ"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4370 }
+
+automaticSNCPSwitchCausedByPDI
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "automatic SNCP switch caused by PDI"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4380 }
+
+automaticSNCPSwitchCausedBySFBER
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Automatic SNCP Switch caused by SFBER"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4390 }
+
+automaticSNCPSwitchCausedBySDBER
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Automatic SNCP Switch caused by SDBER"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4400 }
+
+stmConcatenationError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "STM Concatenation error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4410 }
+
+e3IdleCondition
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "E3 Idle Condition"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4420 }
+
+channelMSSPInconsistentAPSCode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel MSSP inconsistent APS code"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4430 }
+
+
+channelMSSPImproperAPSCodeAPS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel MSSP Improper APS code APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4440 }
+
+channelMSSPNodeIdMismatchAPS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel MSSP Node Id Mismatch APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4450 }
+
+channelMSSPDefaultKAPS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel MSSP Default K APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4460 }
+
+channelMSSPConnectionLossAPS
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "channel MSSP Connection loss APS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4470 }
+
+minimumClockTraceableSDH
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "SDH Minimum clock Traceable"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4480 }
+
+lineIsInWaitToRestoreStateSDH
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "SDH line is in Wait To Restore state "
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4490 }
+
+berThresholdExceededForSignalDegradeHighOrder
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "BER Threshold Exceeded For Signal Degrade - High Order"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4500 }
+
+berThresholdExceededForSignalFailureHighOrder
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "BER Threshold Exceeded For Signal Failure - High Order"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4510 }
+
+berThresholdExceededForSignalDegradeLowOrder
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "BER Threshold Exceeded For Signal Degrade - Low Order"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4520 }
+
+berThresholdExceededForSignalFailureLowOrder
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "BER Threshold Exceeded For Signal Failure - Low Order"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4530 }
+
+failureToSwitchToProtectionHighOrderPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Failure To Switch To Protection - High Order Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4540 }
+
+failureToSwitchToProtectionLowOrderPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Failure To Switch To Protection - Low Order Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4550 }
+
+lofAdministrationUnitLossOfMultiFrame
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LOF - Administration Unit - Loss of Multi Frame"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4560 }
+
+sdhSpanIsInWaitToRestoreState
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "SDH span is in Wait To Restore state"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4570 }
+
+-- End: SDH Traps
+
+a8b10bOutOfSync
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "8B10B Out of Sync"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4755 }
+
+odukPMAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "ODUk: PM Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4760 }
+
+otukAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OTUk: Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4765 }
+
+otukSMBackwardDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OTUk: Backward Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4770 }
+
+odukBackwardDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk: Backward Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4775 }
+
+fecUncorrectedWord
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "FEC Uncorrected Word"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4780 }
+
+gccTerminationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GCC Termination Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4785 }
+
+otukIncomingAlignmentError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OTUk: Incoming Alignment Error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4790 }
+
+odukLockedDefectPM
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "ODUk: Locked Defect - PM"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4795 }
+
+lossOfMultiFrame
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Loss of Multi-Frame"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4800 }
+
+odukOpenConnectionIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk: Open Connection Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4805 }
+
+payloadTypeIdentifierMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Payload Type Identifier Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4810 }
+
+odukTrailTraceIdentifierMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk: Trail Trace Identifier Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4815 }
+
+otukTrailTraceIdentifierMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OTUk: Trail Trace Identifier Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4820 }
+
+equipmentHighLaserBias
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment High Laser Bias"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4825 }
+
+equipmentHighLaserTemp
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment High Laser Temp"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4830 }
+
+equipmentHighLaserPeltier
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment High Laser Peltier"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4835 }
+
+facilityHighRxPower
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Facility High Rx power"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4840 }
+
+equipmentHighTxPower
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment High Tx power"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4845 }
+
+equipmentHighTransceiverVoltage
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment High Transceiver voltage"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4850 }
+
+equipmentLowLaserBias
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Low Laser Bias"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4855 }
+
+equipmentLowLaserTemp
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Low Laser Temp"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4860 }
+
+equipmentLowLaserPeltier
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Low Laser Peltier "
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4865 }
+
+facilityLowRxPower
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Facility Low Rx power"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4870 }
+
+equipmentLowTxPower
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Low Tx power"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4875 }
+
+equipmentLowTransceiverVoltage
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Low Transceiver voltage"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4880 }
+
+equipmentRxLocked
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Rx Locked"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4885 }
+
+equipmentSquelched
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Squelched"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4890 }
+
+equipmentTxLocked
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Tx Locked"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4895 }
+
+otukSignalFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OTUK Signal Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4900 }
+
+odukSignalFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUK Signal Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4905 }
+
+otukSignalDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OTUK Signal Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4910 }
+
+odukSignalDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUK Signal Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4915 }
+
+pluggablePortMissing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Pluggable Port missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4920 }
+
+pluggablePortRateMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Pluggable Port rate mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4925 }
+
+pluggablePortSecurityCodeMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Pluggable Port security code mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4930 }
+
+tciNotSelected
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Tci not selected"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4935 }
+
+tci1ClockFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Tci 1 Clock Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4940 }
+
+odukPMBackwardDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk: PM Backward Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4945 }
+
+odukTCM1BackwardDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk: TCM1 Backward Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4950 }
+
+odukTCM2BackwardDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk: TCM2 Backward Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4955 }
+
+equipmentHighRxTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment High Rx temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4960 }
+
+equipmentLowRxTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Low Rx temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4965 }
+
+tci2ClockFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Tci 2 Clock Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4970 }
+
+equipmentWavelengthMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Wavelength Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4975 }
+
+dspCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "DSP Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4980 }
+
+dspFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "DSP Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 4985 }
+
+
+laserApproachingEndOfLife
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Laser Approaching End of Life"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5000 }
+
+crossconnectLoopback
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Cross-connect Loopback"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5010 }
+
+adminLogoutOfUser
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Admin Logout of User"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5020 }
+
+userLockedOut
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "User Locked Out"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5030 }
+
+adminLockoutOfUser
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Admin Lockout of User"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5040 }
+
+adminLockoutClear
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Admin Lockout Clear"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5050 }
+
+invalidLoginUsername
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Invalid Login: Username"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5060 }
+
+securityInvalidLoginPassword
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Security: Invalid Login - Password - See Audit Log"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5070 }
+
+securityInvalidLoginLockedOut
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Security: Invalid Login - Locked Out - See Audit Log"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5080 }
+
+securityInvalidLoginAlreadyLoggedOn
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Security: Invalid Login - Already Logged On - See Audit Log"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5090 }
+
+loginOfUser
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Login of User"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5100 }
+
+automaticLogoutOfIdleUser
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Automatic Logout of IdleUser"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5110 }
+
+logoutOfUser
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Logout of User"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5120 }
+
+enhancedRemoteFailureIndicationPathServer
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Enhanced Remote Failure Indication - Path - Server"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5200 }
+
+
+enhancedRemoteFailureIndicationPathConnectivity
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Enhanced Remote Failure Indication - Path - Connectivity"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5210 }
+
+enhancedRemoteFailureIndicationPathPayload
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Enhanced Remote Failure Indication - Path - Payload"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5220 }
+
+firewallHasBeenDisabled
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Firewall Has Been Disabled"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5230 }
+
+securityIntrusionDetPwd
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Security Intrusion Attempt Detected - See Audit Log"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5240 }
+
+securityIntrusionDetUser
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Security Intrusion Attempt Detected - See Audit Log"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5250 }
+connectionEquipmentMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Connection Equipment Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5260 }
+
+disableInactiveUser
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Disable Inactive User"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5270 }
+
+disableInactiveClear
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Disable Inactive Clear"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5280 }
+
+
+batteryFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Battery Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5290 }
+
+extremeHighVolt
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Extreme High Volt"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5300 }
+
+extremeLowVolt
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Extreme Low Volt"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5310 }
+
+highVolt
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "High Volt"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5320 }
+
+lowVolt
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Low Volt"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5330 }
+
+suspendUser
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Suspend User"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5340 }
+
+suspendUserClear
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Suspend User Clear"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5350 }
+
+
+lineDccTerminationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Line DCC Termination Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5360 }
+
+multiplexSectionDccTerminationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Multiplex Section DCC Termination Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5370 }
+
+gigaBitEthernetOutOfSync
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "GigaBit Ethernet Out of Sync"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5380 }
+
+sequenceMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Sequence Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5390 }
+
+lossOfAlignment
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Loss of Alignment"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5400 }
+
+outOfUseByAdministrativeCommand
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Out of Use - Administrative Command"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5410 }
+
+outOfUseTransportFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Out of Use - Transport Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5420 }
+
+vcatGroupDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "VCAT Group Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5430 }
+
+vcatGroupDegraded
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "VCAT Group Degraded"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5440 }
+
+vcatGroupIncomplete
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "VCAT Group Incomplete"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5450 }
+
+alarmIndicationSignalInTX
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Alarm Indication Signal in TX"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5460 }
+
+remoteAlarmIndicationInTX
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Remote Alarm Indication in TX"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5470 }
+
+kByteAPSChannelFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Kbyte Channel Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5480 }
+
+apsInvalidMode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "APS Invalid Mode"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5490 }
+
+ipAddressAlreadyInUseWithinTheSameDccArea
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "IP Address A1ready In Use Within The Same DCC Area"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5500 }
+
+nodeNameInUseWithinTheSameDccArea
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Node name already in use within the same DCC Area"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5510 }
+
+rearPanelEthernetLinkRemoved
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Rear Panel Ethernet Link Removed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5520 }
+
+manualSwitchToProtectResultedInNoTrafficSwitch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch To Protect Resulted in No Traffic Switch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5530 }
+
+manualSwitchBackToWorkingResultedInNoTrafficSwitch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Manual Switch Back To Working Resulted in No Traffic Switch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5540 }
+
+forcedSwitchToProtectResultedInNoTrafficSwitch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Forced Switch To Protection Resulted in No Traffic Switch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5550 }
+
+forcedSwitchBackToWorkingResultedInNoTrafficSwitch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Forced Switch Back To Working Resulted in No Traffic Switch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5560 }
+
+duplicateSerialNumberDetectedOnAPluggableEntity
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Duplicate Serial number detected on a pluggable entity"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5570 }
+
+lossOfSignalForOpticalChannel
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Incoming Payload Signal Absent"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5600 }
+
+encapsulationMismatchPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Encapsulation Mismatch Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5610 }
+
+encapsulationMismatchVT
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Encapsulation Mismatch - VT"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5620 }
+
+encapsulationMismatchHighOrderPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Encapsulation Mismatch High Order - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5630 }
+
+encapsulationMismatchLowOrderPath
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Encapsulation Mismatch Low Order - Path"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5640 }
+
+gfpUserPayloadMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GFP User Payload Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5650 }
+
+gfpFibreChannelDistanceExtensionMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GFP Fibre Channel Distance Extension Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5660 }
+
+gfpFibreChannelDistanceExtensionBufferStarvation
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GFP Fibre Channel Distance Extension Buffer Starvation"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5670 }
+
+gfpFibreChannelDistanceExtensionCreditStarvation
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Fibre Channel Distance Extension Credit Starvation"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5680 }
+
+automaticWdmAnsFinished
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Automatic WDM ANS Finished"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5690 }
+
+gfpClientSignalFailDetected
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GFP Client Signal Fail Detected"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5700 }
+
+gfpLossOfFrameDelineation
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GFP Loss of Frame Delineation"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5710 }
+
+gfpExtensionHeaderMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GFP Extension Header Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5730 }
+
+incomingOverheadSignalAbsent
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Incoming Overhead Signal Absent"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5740 }
+
+opticalSafetyRemoteInterlockOn
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Safety Remote Interlock On"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5750 }
+
+automaticPowerControlCorrectionSkipped
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Automatic Power Control Correction Skipped"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5770 }
+
+apcCannotSetValueDueToRangeLimits
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "APC cannot set value due to range limits"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5780 }
+
+lcasVcgMemberTxSideInAddState
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LCAS VCG Member Tx Side In ADD State"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5790 }
+
+farEndManualSwitchBackToWorkingSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End Manual Switch Back to Working - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5800 }
+
+farEndForcedSwitchBackToWorkingSpan
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Far End Forced Switch Back to Working - Span"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5810 }
+
+universalTransponderModuleHardwareFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Universal Transponder Module Hardware Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5820 }
+
+universalTransponderModuleCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Universal Transponder Module Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5830 }
+
+pluginModuleRangeSettingsMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Plug-in Module Range Settings Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5840 }
+
+lcasVcgMemberTxSideInDnuState
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LCAS VCG Member Tx Side In DNU State"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5850 }
+
+lcasControlWordCrcCheckFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LCAS Control Word CRC Check Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5860 }
+
+lcasVcgMemberRxSideInFailState
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "LCAS VCG Member Rx Side In FAIL State"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5870 }
+
+signalLossOnDataInterface
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Signal Loss on Data Interface"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5880 }
+
+synchronizationLossOnDataInterface
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Synchronization Loss on Data Interface"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5890 }
+
+portFAIL
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "PORT FAIL"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5900 }
+
+unreachablePortTargetPower
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Unreachable port target power"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5910 }
+
+portAddPowerDegradeLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Port Add Power Degrade Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5920 }
+
+portAddPowerDegradeHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Port Add Power Degrade High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5930 }
+
+portAddPowerFailLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Port Add Power Fail Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5940 }
+
+portAddPowerFailHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Port Add Power Fail High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 5950 }
+
+automaticPowerControlTerminatedOnManualRequest
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Automatic Power Control Terminated on Manual request"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6000 }
+
+oduk1AlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk-1: Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6010 }
+
+oduk2AlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk-2: Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6020 }
+
+oduk3AlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk-3: Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6030 }
+
+oduk4AlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk-4: Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6040 }
+
+temperatureReadingMismatchBetweenSCCards
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Temperature Reading Mismatch Between SC Cards"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6050 }
+
+voltageReadingMismatchBetweenSCCards
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Voltage Reading Mismatch Between SC Cards"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6060 }
+
+alarmsSuppressedonOutOfGroupVcatMember
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Alarms Suppressed on Out-Of-Group VCAT Member"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6070 }
+
+blsrSoftwareVersionMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "BLSR Software Version Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6080 }
+
+optimized1Plus1ApsPrimaryFacility
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Optimized 1+1 APS Primary Facility"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6090 }
+
+optimized1Plus1ApsPrimarySectionMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Optimized 1+1 APS Primary Section Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6100 }
+
+optimized1Plus1ApsInvalidPrimarySection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Optimized 1+1 APS Invalid Primary Section"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6110 }
+
+compositeClockHighLineVoltage
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Composite Clock High Line Voltage"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6120 }
+
+berThresholdExceededForSignalDegradeVt
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "BER Threshold Exceeded For Signal Degrade - VT"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6130 }
+
+berThresholdExceededForSignalFailureVt
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "BER Threshold Exceeded For Signal Failure - VT"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6140 }
+
+spanLengthOutOfRange
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Span Length Out of Range"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6150 }
+
+idleSignalCondition
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Idle Signal Condition"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6170 }
+
+idleSignalConditionInTx
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Idle Signal Condition in TX"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6180 }
+
+vtPathTraceIdentifierMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "VT Path Trace Identifier Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6190 }
+
+lossOfFrameInTX
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Loss of Frame in TX"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6200 }
+
+provisioningMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Provisioning Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6210 }
+
+sectionTraceIdentifierMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Section Trace Identifier Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6220 }
+
+regeneratorSectionTraceIdentifierMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Regenerator Section Trace Identifier Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6230 }
+
+switchingMatrixModuleFailureWorking
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switching Matrix Module Failure - Working"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6240 }
+
+switchingMatrixModuleFailureProtect
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Switching Matrix Module Failure - Protect"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6250 }
+
+slotCommunicationDisabled
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Slot Communication Disabled"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6260 }
+
+sessionTimeLimitExpired
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Session Time Limit Expired"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6270 }
+
+userPasswordChangeRequired
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "User Password Change Required"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6280 }
+
+isisAdjacencyFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ISIS Adjacency Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6290 }
+
+msspSoftwareVersionMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "MSSP Software Version Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6300 }
+
+remoteAuthenticationFailSeeAuditLog
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Remote Authentication Fail - See Audit Log"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6310 }
+
+ringIsSquelchingStsTraffic
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ring Is Squelching STS Traffic"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6330 }
+
+ringIsSquelchingVtTraffic
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ring Is Squelching VT Traffic"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6340 }
+
+archiveOfAuditLogFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Archival of Audit Log Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6350 }
+
+rprWrapped
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "RPR Wrapped"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6360 }
+
+shelfCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Shelf Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6370 }
+
+duplicatedShelfIdentifier
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Duplicated Shelf Identifier"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6380 }
+
+softwareMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Software Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6390 }
+
+lmpFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "LMP Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6400 }
+
+opticalTerminationIncomplete
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Termination Incomplete"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6410 }
+
+forwardDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Forward Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6420 }
+
+payloadMissingIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Payload Missing Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6430 }
+
+spanMeasurementCannotBePerformed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Span loss not checked"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6440 }
+
+ringIsSquelchingHighOrderTraffic
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ring Is Squelching High Order Traffic"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6450 }
+
+ringIsSquelchingLowOrderTraffic
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Ring Is Squelching Low Order Traffic"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6460 }
+
+badPacketCountExceedsThreshold
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Bad Packet Count Exceeds Threshold"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6470 }
+
+linkLayerKeepAliveFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Link Layer Keep-Alive Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6480 }
+
+autonegotiationRemoteFailureIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Auto-Negotiation Remote Failure Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6490 }
+
+trailSignalFail
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Trail Signal Fail"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6500 }
+
+ds1LoopbackCommandSentToFarEnd
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "DS1 Loopback Command Sent To Far End"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6510 }
+
+multiplexSectionSignalDegraded
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Multiplex Section - Signal Degraded"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6520 }
+
+multiplexSectionExcessiveErrors
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Multiplex Section - Excessive Errors"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6530 }
+
+highOrderPathSignalDegraded
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "High Order Path - Signal Degraded"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6540 }
+
+highOrderPathExcessiveErrors
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "High Order Path - Excessive Errors"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6550 }
+
+lowOrderPathSignalDegraded
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Low Order Path - Signal Degraded"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6560 }
+
+lowOrderPathExcessiveErrors
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Low Order Path - Excessive Errors"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6570 }
+
+regeneratorSectionDccTerminationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Regenerator Section - DCC Termination Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6580 }
+
+networkMemoryPoolLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Network Memory Pool Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6590 }
+
+ospfRoutingTableOverflow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OSPF Routing Table Overflow"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6600 }
+
+autoLaserShutdownDisabled
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Auto Laser Shutdown Disabled"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6610 }
+
+rprProtectionIsActive
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "RPR Protection Is Active"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6630 }
+
+maxRPRStationNumberExceeded
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Max RPR Station Number Exceeded"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6640 }
+
+rprProtectionConfigurationMismatched
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "RPR Protection Configuration Mismatched"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6650 }
+
+reservedBandwidthLinkRateExceededOnRinglet0
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Reserved Bandwidth Link Rate Exceeded On Ringlet0"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6660 }
+
+reservedBandwidthLinkRateExceededOnRinglet1
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Reserved Bandwidth Link Rate Exceeded On Ringlet1"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6670 }
+
+rprInterfaceInPassThroughMode
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "RPR Interface In Pass Through Mode"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6680 }
+
+rprPeerNodeIsMissing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "RPR Peer Node is Missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6690 }
+
+rprRiFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "RPR RI Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6700 }
+
+rprSignalFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "RPR Signal Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6710 }
+
+rprSignalDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "RPR Signal Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6720 }
+
+interlinkFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ADM Peer Cards Interlink Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6730 }
+
+apcWrongGain
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "APC Wrong Gain Set Point"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6740 }
+
+rprSpanMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "RPR Span Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6750 }
+
+efmRemoteFaultIndicationCriticalEvent
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Remote Fault Inidication- Critical Event"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6760 }
+
+efmRemoteFaultIndicationDyingGasp
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Remote Fault Inidication- Dying Gasp"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6770 }
+
+efmRemoteFaultIndicationLinkFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Remote Fault Inidication- Link Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6780 }
+
+efmLinkMonitoringErroredSymbolPeriodEvent
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Link Monitoring- Errored Symbol Period Event"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6790 }
+
+efmLinkMonitoringErroredFrameEvent
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Link Monitoring- Errored Frame Event"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6800 }
+
+efmLinkMonitoringErroredFramePeriodEvent
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Link Monitoring- Errored Frame Period Event"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6810 }
+
+efmLinkMonitoringErroredFrameSecondsSummary
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Link Monitoring- Errored Frame Seconds Summary"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6820 }
+
+efmRemoteLoopbackRequestFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Remote Loopback Request Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6830 }
+
+fastAutomaticProtectionSwitching
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Fast Automatic Protection Switching"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6840 }
+
+fastAutomaticProtectionSwitchingConfigMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Fast Automatic Protection Switching Config Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6850 }
+
+lcasSinkGroupError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "LCAS Sink Group Error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6860 }
+
+lcasVcgMemberRxSideInDnuState
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "LCAS VCG Member Rx Side In DNU State"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6870 }
+
+fcDistanceExtFuncNotEstablished
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION " Fibre Channel Distance Extension Function Not Established"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6880 }
+
+nonCiscoPPMInserted
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Non Cisco PPM Inserted"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6890 }
+
+unqualifiedPPMInserted
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Unqualified PPM Inserted"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6900 }
+
+ftaMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "FanTray Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6910 }
+
+cardPortsUnableToProvideProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Card/Ports Unable To Provide Protection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6920 }
+
+lmpSignalDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "LMP Signal Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6930 }
+
+lmpSignalFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "LMP Signal Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6940 }
+
+lmpUnallocatedDataLink
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "LMP Unallocated Data Link"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6950 }
+
+frontPortLinkLoss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "TCC Front Port Link Loss"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6960 }
+
+bertEnbl
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "BERT Enabled "
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6970 }
+
+bertSyncFail
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "BERT Synchronization Status Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6975 }
+
+workQueueFull
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Work Queue Full"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 6980 }
+
+equipmentPowerFailureAtConnectorA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment power failure at connector A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7000 }
+
+equipmentPowerFailureAtConnectorB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment power failure at connector B"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7005 }
+
+equipmentPowerFailureAtReturnConnectorA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment power failure at return connector A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7010 }
+
+equipmentPowerFailureAtReturnConnectorB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment power failure at return connector B"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7015 }
+
+bridgeAndRollHasOccurred
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Bridge and Roll Has Occurred"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7055 }
+
+bridgeAndRollIsPendingAValidSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Bridge and Roll is Pending a Valid Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7060 }
+
+clockBusFailureTscA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Clock Bus Failure - Shelf Controller A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7160 }
+
+clockBusFailureTscB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Clock Bus Failure - Shelf Controller B"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7165 }
+
+ospfHelloFail
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OSPF Hello Fail"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7185 }
+
+openIOSlots
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Open IO Slots"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7200 }
+
+lossOfClockFromMateShelfController
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Loss of Clock from Mate Shelf Controller"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7210 }
+
+virtualLanAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Virtual Lan AIS"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7225 }
+
+dcuLossFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "DCU Loss Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7230 }
+
+ochncMaintenance
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OCHNC Maintenance"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7235 }
+
+ramanLaserShutdown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Raman Laser Shutdown"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7240 }
+
+losOfRamanSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Loss Of Raman Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7245 }
+
+mcastMacTableFull
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Multicast Mac Address Table Full"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7250 }
+
+multicastMacAddressAliasing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Multicast Mac Address Aliasing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7255 }
+
+ramanPwrProtOn
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Raman Power Protection On"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7260 }
+
+cppPeerNotResponding
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "CPP Peer Not Responding"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7265 }
+
+voaControlLoopDisableDueToExcessiveCounterPropagationLight
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "VOA Control Loop Disable Due To Excessive Counter-Propagation Light"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7275 }
+
+wizardIsRunning
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Wizard Is Running"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7280 }
+
+ramanGainNotReached
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Raman Span Not Tuned"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7285 }
+
+
+pprForwardDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "pprForwardDefectIndication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7295 }
+
+pprBackwardDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "pprBackwardDefectIndication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7300 }
+
+pprCoordinatedMaintenance
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "pprCoordinatedMaintenance"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7305 }
+
+pprTriggerThresholdBERExceeded
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "pprTriggerThresholdBERExceeded"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7310 }
+
+localFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Local Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7315 }
+
+remoteFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Remote Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7320 }
+
+efmRemoteLoopbackConfigured
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Port In Remote Loopback"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7325 }
+
+efmPeerMissing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "EFM Link To Peer Missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7330 }
+
+eqptDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Equipment Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7335 }
+
+excessiveBackPropagation
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Excessive Back Propagation"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7340 }
+
+remoteMaintenanceEndPointIsDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "CFM Remote Maintenance End Point Is Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7345 }
+
+crossConnectedCFMService
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Cross Connected CFM Service"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7350 }
+
+cfmLoop
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "CFM Loop"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7355 }
+
+cfmConfigurationError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "CFM Configuration Error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7360 }
+
+outOfChannelGroupBundle
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Out Of Channel Group Bundle"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7365 }
+
+repNeighborAdjacencyFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "REP Neighbor Adjacency Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7370 }
+
+repLinkFlapping
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "REP Link Flapping"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7375 }
+
+faultInREPSegment
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Fault In REP Segment"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7380 }
+
+primaryREPEdgePortElected
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Primary REP Edge Port Elected"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7385 }
+
+secondaryREPEdgePortElected
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Secondary REP Edge Port Elected"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7390 }
+
+stcnREPGenerated
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "STCN REP Generated"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7395 }
+
+vlbREPActivated
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "VLB REP Activated"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7400 }
+
+vlbREPTriggerSoakingDelayActive
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "VLB REP Trigger Soaking Delay Active"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7405 }
+
+
+wanSyncloss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ethernet Syncloss On WAN Port"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7410 }
+
+laserShutdownDueToWavelengthDrift
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "laser Shutdown Due To Wavelength Drift"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7415 }
+
+manualLaserRestart
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "manual Laser Restart"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7420 }
+
+laserShutdownDueToNonCiscoPPMInserted
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "laserShutdownDueToNonCiscoPPMInserted"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7425 }
+
+ethernetOSCTerminationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ethernet OSC Termination Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7430 }
+
+softwareSignatureVerificationFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "software Signature Verification Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7445 }
+
+protectVolumeSoftwareSignatureVerificationFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Volume Software Signature Verification"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7450 }
+
+activeVolumeSoftwareSignatureVerificationFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Active Software Signature Verification Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7455 }
+
+peerPortClientSignalFailDetected
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Peer Port Client Signal Fail Detected"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7460 }
+
+channelShutdownDueToWavelengthDrift
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Channel Shutdown Due to Wavelength Drift"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7465 }
+
+usbWriteFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "USB Write Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7475 }
+
+usbSyncInProgress
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "USB Sync in Progress"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7480 }
+
+autoSensingUnableToDetectValidPayload
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Auto-Sensing Unable To Detect Valid Payload"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7485 }
+
+payloadAutoSensingInProgress
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Payload Auto-Sensing In Progress"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7490 }
+
+gfpClientSignalFailDetectedDueToSigloss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GFP Client Signal Fail Detected Due To Sigloss"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7495 }
+
+gfpClientSignalFailDetectedDueToSyncloss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "GFP Client Signal Fail Detected Due To Syncloss"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7500 }
+
+pmdDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "PMD Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7510 }
+
+standbyTccNEClockIsInternalClock
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Standby Tcc NE Clock Is Internal Clock"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7515 }
+
+chromaticDispersionValue
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "chromatic Dispersion Value"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7520 }
+
+packetTransportServiceFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Packet Transport Service Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7525 }
+
+satellitePanelDiscoveryFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Discovery Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7530 }
+
+satellitePanelActiveLinkFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Active Link Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7535 }
+
+satellitePanelCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7540 }
+
+satellitePanelImproperConfiguration
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Improper Configuration"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7545 }
+
+satellitePanelFanMismatchOfEquipmentAndAttributes
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Fan Mismatch Of Equipment And Attributes"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7550 }
+
+satellitePanelFanFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Fan Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7555 }
+
+satellitePanelPartialFanFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Partial Fan Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7560 }
+
+satellitePanelFANManufacturingDataMemoryEEPROMFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel FAN Manufacturing Data Memory (EEPROM) Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7565 }
+
+satellitePanelFANUnitIsMissing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel FAN Unit Is Missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7570 }
+
+satellitePanelIndustrialHighTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Industrial High Temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7575 }
+
+satellitePanelHighTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel High Temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7580 }
+
+satellitePanelBatteryFailureA
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Satellite Panel Battery Failure A"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7585 }
+
+plannedSwitchOver
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Planned Switch Over"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7590 }
+
+protectionCardConfigurationMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "protection CardConfiguration Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7595 }
+
+routerProcessorSwitchOver
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Router Processor Switch Over"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7600 }
+
+runningLowOnResources
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Running Low On Resources"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7605 }
+
+noMoreResourcesAreAvailable
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "No More Resources Are Available"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7610 }
+
+esmcFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ESMC Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7615 }
+
+licenseWillExpireWithin24Hours
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "License Will Expire Within 24 Hours"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7620 }
+
+licenseWillExpireAnytimeAfter1DayButBefore14Days
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "license Will Expire Anytime After 1Day But Before 14Days"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7625 }
+
+licenseIsExpired
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "license Is Expired"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7630 }
+
+licenseCountViolation
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "license Count Violation"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7635 }
+
+temporaryLicenseIsInUse
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Temporary License Is In Use"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7640 }
+
+evaluationLicenseIsInUse
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Evaluation License Is In Use"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7645 }
+
+licenseIsMissing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "License Is Missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7650 }
+
+pseudowireDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Pseudowire Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7655 }
+
+workingPseudowireControlPlaneDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Pseudowire Control Plane Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7660 }
+
+protectPseudowireControlPlaneDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Pseudowire Control Plane Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7665 }
+
+workingPseudowireConnectivityCheckDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Pseudowire Connectivity Check Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7670 }
+
+protectPseudowireConnectivityCheckDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Pseudowire Connectivity Check Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7675 }
+
+pseudowireTrafficSwitchedToProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Pseudowire Traffic Switched To Pretection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7680 }
+
+workingPseudowireLocalAcTxPortFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Pseudowire Local AcTx Port Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7685 }
+
+protectPseudowireLocalAcTxPortFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Pseudowire Local AcTx Port Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7690 }
+
+workingPseudowireLocalAcRxPortFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Pseudowire Local AcRx Port Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7695 }
+
+protectPseudowireLocalAcRxPortFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Pseudowire Local AcRx Port Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7700 }
+
+workingPseudowireRemoteAcTxPortFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Pseudowire Remote AcTx Port Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7705 }
+
+protectPseudowireRemoteAcTxPortFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Pseudowire Remote AcTx Port Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7710 }
+
+workingPseudowireRemoteAcRxPortFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "working Pseudowire Remote AcRx Port Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7715 }
+
+protectPseudowireRemoteAcRxPortFault
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Pseudowire Remote AcRx Port Fault"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7720 }
+
+slaThresholdCrossAlert
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "SLA Threshold Cross Alert"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7725 }
+
+protectLocalPseudowireNotForwarding
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Local Pseudowire Not Forwarding"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7730 }
+
+workingPseudowireNotForwarding
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Remote Pseudowire Not Forwarding"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7735 }
+
+protectPseudowireNotForwarding
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Remote Pseudowire Not Forwarding"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7740 }
+
+tpTunnelDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Tp Tunnel Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7745 }
+
+workingLabelSwitchedPathDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Label Switched Path Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7750 }
+
+protectLabelSwitchedPathDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Label Switched Path Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7755 }
+
+workingLabelSwitchedPathAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Label Switched Path Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7760 }
+
+protectLabelSwitchedPathAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Label Switched Path Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7765 }
+
+workingLabelSwitchedPathRemoteDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Label Switched Path Remote Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7770 }
+
+protectLabelSwitchedPathRemoteDefectIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Label Switched Path Remote Defect Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7775 }
+
+bidirectionalForwardDetectionDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Bidirectional Forward Detection Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7780 }
+
+tpTrafficSwitchedFromWorkingToProtection
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Tp Traffic Switched From Working To Protection"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7785 }
+
+workingTpLockout
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "working Tp Lockout"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7790 }
+
+protectTpLockout
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "protect Tp Lockout"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7795 }
+
+
+ethernetFlowPointFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ethernet Flow Point Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7800 }
+
+teTunnelDown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "TE Tunnel Down"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7805 }
+
+macSystemLimitReached
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "MAC System Limit Reached"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7810 }
+
+macBridgeDomainLimitReached
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "MAC Bridge Domain Limit Reached"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7815 }
+
+autoSensingDisabled
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Auto Sense Disabled"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7820 }
+
+smBackwardIncomingAlignmentError
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "SM Backward Incoming Alignment Error"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7825 }
+
+resourceAllocationFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Resource Allocation Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7830 }
+
+lossOfDFBSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "loss Of DFB Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7835 }
+
+
+workingLabelSwitchedPathLinkDownIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Label Switched Path Link Down Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7840 }
+
+protectLabelSwitchedPathLinkDownIndication
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Label Switched Path Link Down Indication"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7845 }
+
+workingLabelSwitchedPathLockReport
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Working Label Switched Path Lock Report"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7850 }
+
+protectLabelSwitchedPathLockReport
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Protect Label Switched Path Lock Report"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7855 }
+
+satellitePanelBatteryFailureB
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "satellite Panel Battery FailureB"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7860 }
+
+highBitErrorRate
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "High Bit Error Rate"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7865 }
+
+backPanelFacilityLoopback
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Back Panel Facility Loopback"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7870 }
+
+backPanelTerminalLoopback
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Back Panel Terminal Loopback"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7875 }
+
+trunkPayloadTypeMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Payload Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7880 }
+
+invalidMuxponderConfiguration
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Invalid Muxponder Configuration"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7885 }
+
+coolingProfileMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Cooling Profile Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7890 }
+
+trunkOduAlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Trunk ODU: Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7895 }
+
+companionCardMissing
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Companion Card Missing"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7900 }
+
+controlPlaneUnverifiedClearedAlarmsPresent
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Control Plane Unverified Cleared Alarms Present"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7905 }
+
+powerConsumptionLimitHasCrossed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Power Consumption Limit Has Crossed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7910 }
+
+masterKeyExchangeFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Master Key Exchange Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7915 }
+
+unitHighTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Unit High Temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7930 }
+
+overTemperatureUnitProtected
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Over Temperature Unit Protected"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7935 }
+
+seqMismatchCount
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Sequence Mismatch Count"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7945 }
+
+keyProgramOnAlteraFpgaFailed
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Key Program On Altera FPGA Failed"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7960 }
+
+duplicateNodeControllerDetected
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Duplicate Node Controller Detected"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7970 }
+
+restorationInProg
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Restoration in Progress"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7975 }
+
+ramanPumpsCalibrationProcedureIsRunning
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Raman Calibration Running"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7980 }
+
+ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Raman Calibration Pending"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 7985 }
+
+odukTCM1AlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "ODUk: TCM1 Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13100 }
+
+odukTCM2AlarmIndicationSignal
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "ODUk: TCM2 Alarm Indication Signal"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13105 }
+
+odukLockedDefectTCM1
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Locked Defect - TCM1"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13110 }
+
+odukLockedDefectTCM2
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Locked Defect - TCM2"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13115 }
+
+otukLossOfFrame
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "OTUk: Loss Of Frame"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13120 }
+
+odukOpenConnectionIndicationTCM1
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Open Connection Indication TCM1"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13125 }
+
+odukOpenConnectionIndicationTCM2
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Open Connection Indication TCM2"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13130 }
+
+odukTrailTraceIdentifierMismatchTCM1
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Trail Trace Identifier Mismatch TCM1"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13135 }
+
+odukTrailTraceIdentifierMismatchTCM2
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Trail Trace Identifier Mismatch TCM2"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13140 }
+
+odukSignalFailureTCM1
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Signal Failure - TCM1"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13145 }
+
+odukSignalFailureTCM2
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Signal Failure - TCM2"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13150 }
+
+odukSignalDegradeTCM1
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Signal Degrade - TCM1"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13155 }
+
+odukSignalDegradeTCM2
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "ODUk Signal Degrade - TCM2"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13160 }
+
+lossOfChannel
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Loss of Channel"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13165 }
+
+fecMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "FEC Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13170 }
+
+timSectionMonitorTraceIdentifierMismatchFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "TIM Section Monitor - Trace Identifier Mismatch Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13175 }
+
+automaticLaserShutdown
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Automatic Laser Shutdown"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13180 }
+
+shutterInsertionLossVariationDegradeLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Shutter Insertion Loss Variation Degrade Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13200 }
+
+opticalChannelDeactivationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Channel de-activation failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13205 }
+
+shutterInsertionLossVariationDegradeHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Shutter Insertion Loss Variation Degrade High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13210 }
+
+networkTopologyIncomplete
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Network Topology Incomplete"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13215 }
+
+pluginModuleCommunicationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Plug-in Module Communication Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13220 }
+
+opticalNetworkTypeMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Network Type Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13225 }
+
+opticalPowerDegradeLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Optical Power Degrade Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13230 }
+
+automaticPowerControlFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Automatic Power Control Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13235 }
+
+opticalPowerDegradeHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Power Degrade High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13240 }
+
+automaticPowerControlDisabled
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Automatic Power Control Disabled"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13245 }
+
+opticalPowerFailureLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Power Failure Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13250 }
+
+ringIdMismatch
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Ring Id Mismatch"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13255 }
+
+opticalPowerFailureHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Power Failure High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13260 }
+
+lossOfContinuity
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Loss Of Continuity"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13270 }
+
+variableOpticalAttenuatorDegradeLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Variable Optical Attenuator Degrade Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13280 }
+
+variableOpticalAttenuatorDegradeHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Variable Optical Attenuator Degrade High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13290 }
+
+variableOpticalAttenuatorFailureLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Variable Optical Attenuator Failure Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13300 }
+
+variableOpticalAttenuatorFailureHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Variable Optical Attenuator Failure High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13310 }
+
+laserBiasDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Laser Bias Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13320 }
+
+laserBiasFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "aser Bias Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13330 }
+
+laserTemperatureDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Laser Temperature Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13340 }
+
+opticalAmplifierGainDegradeLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Amplifier Gain Degrade Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13350 }
+
+opticalAmplifierGainDegradeHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Amplifier Gain Degrade High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13360 }
+
+opticalAmplifierGainFailureLow
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Amplifier Gain Failure Low"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13370 }
+
+opticalAmplifierGainFailureHigh
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Amplifier Gain Failure High"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13380 }
+
+opticalChannelConnectionFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Channel connection failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13390 }
+
+opticalChannelIncomplete
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Channel Incomplete"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13395 }
+
+opticalChannelActivationFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Channel activation failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13400 }
+
+laserAutoPowerReduction
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Laser Auto Power Reduction"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13410 }
+
+caseTemperatureDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Case Temperature Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13420 }
+
+fiberTemperatureDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Fiber Temperature Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13430 }
+
+shutterOpen
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Shutter Open"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13440 }
+
+awgTemperatureDegrade
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "AWG Temperature Degrade"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13450 }
+
+awgTemperatureFailure
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "AWG Temperature Failure"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13460 }
+
+awgOverTemperature
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "AWG Over-Temperature"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13470 }
+
+opticalAmplifierInitialization
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "Optical Amplifier Initialization"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13480 }
+
+awgWarmUp
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION "AWG Warm Up"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13490 }
+
+incSigloss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Incoming Signal Loss on Fibre Channel Interface"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13510 }
+
+incSyncloss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Incoming Synchronization Loss on Fibre Channel Interface"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13515 }
+
+incGfpOutOfFrame
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Out Of Frame Detected by GFP Receiver"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13520 }
+
+incGfpSigLoss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Client Signal Loss Frames Detected by GFP Receiver"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13525 }
+
+incGfpSyncLoss
+ NOTIFICATION-TYPE
+ OBJECTS {
+ cerent454NodeTime,
+ cerent454AlarmState,
+ cerent454AlarmObjectType,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmObjectName,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "Client Sychronization Loss Frames Detected by GFP Receiver"
+ --#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
+ --#ARGUMENTS {$2, $3, $4, $5, $6, $8}
+ --#GENERIC 6
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 0
+ ::= { cerent454V2Events 13530 }
+
+node454Group OBJECT-GROUP
+ OBJECTS {
+ cerent454SoftwareVersion }
+ STATUS current
+ DESCRIPTION
+ "The group for node related objects"
+ ::= { cerent454Groups 10 }
+
+alarm454Group OBJECT-GROUP
+ OBJECTS {
+ cerent454AlarmCount,
+ cerent454AlarmObjectIndex,
+ cerent454AlarmObjectType,
+ cerent454AlarmSlotNumber,
+ cerent454AlarmPortNumber,
+ cerent454AlarmLineNumber,
+ cerent454AlarmType,
+ cerent454AlarmState,
+ cerent454AlarmSeverity,
+ cerent454AlarmStatus,
+ cerent454AlarmServiceAffecting,
+ cerent454AlarmTimeStamp,
+ cerent454AlarmObjectName,
+ cerent454AlarmAdditionalInfo
+ }
+ STATUS current
+ DESCRIPTION
+ "The group for node related objects"
+ ::= { cerent454Groups 20 }
+
+event454Group NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ alarmUnknown,
+ alarmCutoffIsInManualMode,
+ failureDetectedExternalToTheNE,
+ externalError,
+ excessiveSwitching,
+ sdccTerminationFailure,
+ incomingFailureCondition,
+ alarmIndicationSignal,
+ alarmIndicationSignalLine,
+ alarmIndicationSignalPath,
+ alarmIndicationSignalVT,
+ apsChannelFailure,
+ channelByteFailureAPS,
+ channelProtectionSwitchingChannelMatchFailureAPS,
+ channelAutomaticProtectionSwitchModeMismatchAPS,
+ farEndProtectionLineFailure,
+ inconsistentAPSCode,
+ improperAPSCode,
+ nodeIdMismatch,
+ channelDefaultKAPS,
+ connectionLoss,
+ bipolarViolation,
+ carrierLossOnTheLAN,
+ concatenationErrorSTS,
+ excessCollisionsOnTheLAN,
+ facilityFailure,
+ farEndAIS,
+ farEndMultipleDS1LOSDetectedOnDS3,
+ farEndDS1EqptFailNonServiceAffecting,
+ farEndDS1EqptFailServiceAffecting,
+ farEndSingleDS1LOS,
+ farEndDS3EqptFailNonServiceAffecting,
+ farEndDS3EqptFailServiceAffecting,
+ farEndCommonEquipmentFailureNonServiceAffecting,
+ farEndIDLE,
+ farEndLOS,
+ farEndLOF,
+ farEndBlockError,
+ ds3IdleCondition,
+ lossOfFrame,
+ lossOfPointer,
+ lossOfPointerPath,
+ lossOfPointerVT,
+ lossOfSignal,
+ outOfFrame,
+ pathSelectorFailure,
+ remoteAlarmIndication,
+ remoteFailureIndication,
+ remoteFailureIndicationLine,
+ remoteFailureIndicationPath,
+ remoteFailureIndicationVT,
+ signalDegrade,
+ severelyErroredFrame,
+ signalFailure,
+ signalLabelMismatchFailure,
+ payloadDefectIndication,
+ payloadDefectIndicationPath,
+ payloadLabelMismatchPath,
+ signalLabelMismatchFailurePayloadLabelMismatchVT,
+ unequippedPath,
+ signalLabelMismatchFailureUnequippedVT,
+ lossOfSynchronization,
+ outOfSynchronization,
+ primarySynchronizationReferenceFailure,
+ secondarySynchronizationReferenceFailure,
+ thirdSynchronizationReferenceFailure,
+ fourthSynchronizationReferenceFailure,
+ fifthSynchronizationReferenceFailure,
+ sixthSynchronizationReferenceFailure,
+ failedToReceiveSynchronizationStatusMessage,
+ synchronizationStatusMessagesAreDisabledOnThisInterface,
+ stratum1PrimaryReferenceSourceTraceable,
+ synchronizedTraceabilityUnknown,
+ stratum2Traceable,
+ transitNodeClockTraceable,
+ stratum3ETraceable,
+ stratum3Traceable,
+ sonetMinimumClockTraceable,
+ stratum4Traceable,
+ doNotUseForSynchronization,
+ reservedForNetworkSynchronizationUse,
+ outgoingFailureCondition,
+ remoteDefectIndicationLine,
+ remoteDefectIndicationPath,
+ freeRunningSynchronizationMode,
+ holdoverSynchronizationMode,
+ fastStartSynchronizationMode,
+ internalFault,
+ internalError,
+ internalMessageError,
+ mismatchOfEquipmentAndAttributes,
+ watchdogTimerTimeout,
+ softwareFaultOrFailure,
+ softwareFaultDataIntegrityFault,
+ programFailure,
+ controlEquipmentFailure,
+ primaryNonVolatileBackupMemoryFailure,
+ secondaryNonVolatileBackupMemoryFailure,
+ controlBusFailure,
+ controlBus1Failure,
+ controlBus2Failure,
+ tccAToShelfSlot1DROP1CommunicationFailure,
+ tccAToShelfSlot2DROP2CommunicationFailure,
+ tccAToShelfSlot3DROP3CommunicationFailure,
+ tccAToShelfSlot4DROP4CommunicationFailure,
+ tccAToShelfSlot5TRUNK1CommunicationFailure,
+ tccAToShelfSlot6TRUNK2CommunicationFailure,
+ tccAToShelfSlot7TCCACommunicationFailure,
+ tccAToShelfSlot8XCONACommunicationFailure,
+ tccAToShelfSlot9AICCommunicationFailure,
+ tccAToShelfSlot10XCONBCommunicationFailure,
+ tccAToShelfSlot11TCCBCommunicationFailure,
+ tccAToShelfSlot12TRUNK3CommunicationFailure,
+ tccAToShelfSlot13TRUNK4CommunicationFailure,
+ tccAToShelfSlot14DROP5CommunicationFailure,
+ tccAToShelfSlot15DROP6CommunicationFailure,
+ tccAToShelfSlot16DROP7CommunicationFailure,
+ tccAToShelfSlot17DROP8CommunicationFailure,
+ tccAToDCCAProcessorCommunicationFailure,
+ tccBToShelfSlot1DROP1CommunicationFailure,
+ tccBToShelfSlot2DROP2CommunicationFailure,
+ tccBToShelfSlot3DROP3CommunicationFailure,
+ tccBToShelfSlot4DROP4CommunicationFailure,
+ tccBToShelfSlot5TRUNK1CommunicationFailure,
+ tccBToShelfSlot6TRUNK2CommunicationFailure,
+ tccBToShelfSlot7TCCACommunicationFailure,
+ tccBToShelfSlot8XCONACommunicationFailure,
+ tccBToShelfSlot9AICCommunicationFailure,
+ tccBToShelfSlot10XCONBCommunicationFailure,
+ tccBToShelfSlot11TCCBCommunicationFailure,
+ tccBToShelfSlot12TRUNK3CommunicationFailure,
+ tccBToShelfSlot13TRUNK4CommunicationFailure,
+ tccBToShelfSlot14DROP5CommunicationFailure,
+ tccBToShelfSlot15DROP6CommunicationFailure,
+ tccBToShelfSlot16DROP7CommunicationFailure,
+ tccBToShelfSlot17DROP8CommunicationFailure,
+ tccBToDCCBProcessorCommunicationFailure,
+ controlEquipmentControlCommunicationsEquipmentFailure,
+ controlProcessorFailure,
+ workingMemoryFailure,
+ interconnectionEquipmentFailure,
+ payloadBusFailureToIOSlot1XCONSlot8,
+ payloadBusFailureToIOSlot2XCONSlot8,
+ payloadBusFailureToIOSlot3XCONSlot8,
+ payloadBusFailureToIOSlot4XCONSlot8,
+ payloadBusFailureToIOSlot5XCONSlot8,
+ payloadBusFailureToIOSlot6XCONSlot8,
+ payloadBusFailureToIOSlot12XCONSlot8,
+ payloadBusFailureToIOSlot13XCONSlot8,
+ payloadBusFailureToIOSlot14XCONSlot8,
+ payloadBusFailureToIOSlot15XCONSlot8,
+ payloadBusFailureToIOSlot16XCONSlot8,
+ payloadBusFailureToIOSlot17XCONSlot8,
+ payloadBusFailureToIOSlot1XCONSlot10,
+ payloadBusFailureToIOSlot2XCONSlot10,
+ payloadBusFailureToIOSlot3XCONSlot10,
+ payloadBusFailureToIOSlot4XCONSlot10,
+ payloadBusFailureToIOSlot5XCONSlot10,
+ payloadBusFailureToIOSlot6XCONSlot10,
+ payloadBusFailureToIOSlot12XCONSlot10,
+ payloadBusFailureToIOSlot13XCONSlot10,
+ payloadBusFailureToIOSlot14XCONSlot10,
+ payloadBusFailureToIOSlot15XCONSlot10,
+ payloadBusFailureToIOSlot16XCONSlot10,
+ payloadBusFailureToIOSlot17XCONSlot10,
+ timeSlotInterchangeEquipmentFailure,
+ equipmentFailure,
+ highTemperature,
+ invalidMACAddress,
+ boardFailure,
+ diagnosticFailure,
+ mediumAccessControlFailure,
+ facilityTerminationEquipmentFailure,
+ automaticLaserShutoffDueToHighTemperature,
+ failureToReleaseFromProtection,
+ receiverFailure,
+ transmitFailure,
+ facilityTerminationEquipmentReceiverMissing,
+ facilityTerminationEquipmentTransmitterMissing,
+ failureToSwitchToProtection,
+ failureToSwitchToProtectionRing,
+ failureToSwitchToProtectionSpan,
+ failureToSwitchToProtectionPath,
+ fanFailure,
+ equipmentUnitPlugIn,
+ nePowerFailureAtConnector,
+ fuseAlarm,
+ synchronizationUnitFailure,
+ synchronizationSwitchingEquipmentFailure,
+ equipmentUnitUnplugged,
+ loopback,
+ ds1LoopbackDueToFEACCommand,
+ loopbackCommandSentToFarEndDS1,
+ ds3LoopbackDueToFEACCommand,
+ ds3LoopbackCommandSentToFarEnd,
+ ds2LoopbackDueToFarEndCommand,
+ ds2LoopbackCommandSentToFarEnd,
+ facilityLoopback,
+ networkLoopback,
+ terminalLoopback,
+ manuallyCausedAbnormalCondition,
+ ethernetBridgeIsNewRootOfSpanningTree,
+ ethernetBridgeTopologyChange,
+ normalCondition,
+ embeddedOperationsChannelFailureLinkDown,
+ peerStateMismatch,
+ proceduralError,
+ improperRemoval,
+ duplicateNodeID,
+ blsrOutOfSync,
+ blsrMultiNodeTableUpdateCompleted,
+ protectionUnitNotAvailable,
+ performanceMonitorThresholdCrossingAlert,
+ protectionSwitch,
+ recoveryOrServiceProtectionActionHasBeenInitiated,
+ automaticSystemReset,
+ automaticUPSRSwitchCausedByAIS,
+ automaticUPSRSwitchCausedByLOP,
+ automaticUPSRSwitchCausedByUNEQ,
+ automaticUPSRSwitchCausedByPDI,
+ automaticUPSRSwitchCausedBySFBER,
+ automaticUPSRSwitchCausedBySDBER,
+ coldRestart,
+ forcedSwitchBackToWorking,
+ forcedSwitchBackToWorkingRing,
+ forcedSwitchBackToWorkingSpan,
+ forcedSwitchToProtection,
+ forcedSwitchToProtectionRing,
+ forcedSwitchToProtectionSpan,
+ workingFacilityOrEquipmentForcedToSwitchToProtectionPath,
+ initializationInitiated,
+ lockoutOfProtection,
+ lockoutOfProtectionRing,
+ lockoutOfProtectionSpan,
+ lockoutOfProtectionPath,
+ lockoutOfWorking,
+ lockoutOfWorkingRing,
+ lockoutOfWorkingSpan,
+ manualSystemReset,
+ manualSwitchToInternalClock,
+ manualSwitchToPrimaryReference,
+ manualSwitchToSecondReference,
+ manualSwitchToThirdReference,
+ manualSwitchToFourthReference,
+ manualSwitchToFifthReference,
+ manualSwitchToSixthReference,
+ manualSwitchBackToWorking,
+ manualSwitchBackToWorkingRing,
+ manualSwitchBackToWorkingSpan,
+ manualSwitchToProtection,
+ manualSwitchToProtectionRing,
+ manualSwitchToProtectionSpan,
+ manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath,
+ powerfailRestart,
+ ringIsSquelchingTraffic,
+ softwareDownloadInProgress,
+ switchToInternalClock,
+ switchToPrimaryReference,
+ switchToSecondReference,
+ switchToThirdReference,
+ switchToFourthReference,
+ switchToFifthReference,
+ switchToSixthReference,
+ systemReboot,
+ switchedBackToWorking,
+ switchedToProtection,
+ warmRestart,
+ ringIsInWaitToRestoreState,
+ manualSwitchRequest,
+ forcedSwitchRequest,
+ lockoutSwitchRequest,
+ rmonHistoriesAndAlarmsResetReboot,
+ rmonThresholdCrossingAlarm,
+ alarmsSuppressedByUserCommand,
+ alarmsSuppressedForMaintenance,
+ switchingMatrixModuleFailure,
+ lanConnectionPolarityReversed,
+ autonomousPMReportMessageInhibited,
+ ioSlotToXCONCommunicationFailure,
+ stsPathTraceIdentifierMismatch,
+ nePowerFailureAtConnectorA,
+ nePowerFailureAtConnectorB,
+ freeMemoryOnCardVeryLow,
+ freeMemoryOnCardNearZero,
+ exerciseRequestOnRing,
+ exerciseRequestOnSpan,
+ squelchingPath,
+ extraTrafficPreempted,
+ farEndLockoutOfWorkingRing,
+ farEndLockoutOfWorkingSpan,
+ farEndLockoutOfProtectionRing,
+ farEndLockoutOfProtectionAllSpans,
+ farEndWorkingFacilityForcedToSwitchToProtectionRing,
+ farEndWorkingFacilityForcedToSwitchToProtectionSpan,
+ farEndManualSwitchOfWorkingFacilityToProtectionRing,
+ farEndManualSwitchOfWorkingFacilityToProtectionSpan,
+ farEndExercisingRing,
+ farEndExercisingSpan,
+ farEndBERThresholdPassedForSignalFailureRing,
+ farEndBERThresholdPassedForSignalFailureSpan,
+ farEndBERThresholdPassedForSignalDegradeRing,
+ farEndBERThresholdPassedForSignalDegradeSpan,
+ apsChannelFarEndProtectionLineSignalDegrade,
+ ringSwitchIsActiveOnTheEastSide,
+ ringSwitchIsActiveOnTheWestSide,
+ spanSwitchIsActiveOnTheEastSide,
+ spanSwitchIsActiveOnTheWestSide,
+ uniDirectionalFullPassThroughIsActive,
+ biDirectionalFullPassThroughIsActive,
+ kBytesPassThroughIsActive,
+ ringIsSegmented,
+ ringTopologyIsUnderConstruction,
+ lockoutOfProtectionAllSpans,
+ farEndOfFiberIsProvisionedWithDifferentRingID,
+ bothEndsOfFiberProvisionedAsEastOrBothAsWest,
+ autonomousMessagesInhibited,
+ trafficStormOnLANLANTemporarilyDisabled,
+ reptdbchgMessagesInhibited,
+ securityUserIDHasExpired,
+ partialFanFailure,
+ forcedSwitchRequestOnRing,
+ forcedSwitchRequestOnSpan,
+ lockoutSwitchRequestOnRing,
+ lockoutSwitchRequestOnSpan,
+ manualSwitchRequestOnRing,
+ manualSwitchRequestOnSpan,
+ communicationFailurePeerToPeerSlotControlBusA,
+ communicationFailurePeerToPeerSlotControlBusB,
+ controllerAToShelfSlotCommunicationFailure,
+ controllerBToShelfSlotCommunicationFailure,
+ interconnectionEquipmentFailureWorkingPayloadBus,
+ interconnectionEquipmentFailureProtectPayloadBus,
+ inhibitSwitchToProtectRequestOnEquipment,
+ inhibitSwitchToWorkingRequestOnEquipment,
+ exercisingRingSuccessfully,
+ exercisingSpanSuccessfully,
+ spanIsInWaitToRestoreState,
+ exerciseRequestOnRingFailed,
+ exerciseRequestOnSpanFailed,
+ farEndLockoutOfProtectionSpan,
+ manufacturingDataMemoryEEPROMFailure,
+ replaceableEquipmentOrUnitIsMissing,
+ softwareDownloadFailed,
+ extraTrafficPCADropped,
+ etherTxOversubscribed,
+ etherRxOverSubscribed,
+ etherTxExcessFlowCtrl,
+ etherRxExcessFlowCtrl,
+ transportLayerFailure,
+ etherTxUnderrun,
+ synchronizationReferenceFrequencyOutOfBounds,
+ ntpOrSntpHostFailure,
+ peerCardNotResponding,
+ alarmsAndEventsSuppressedForThisObject,
+ ds3FrameFormatMismatch,
+ timSectionTraceIdentifierMismatchFailure,
+ aisMultiplexSectionAlarmIndicationSignal,
+ rdiMultiplexSectionRemoteDefectOrAlarmIndication,
+ timHighOrderTraceIdentifierMismatchFailure,
+ aisAdministrationUnitAlarmIndicationSignal,
+ lopAdministrationUnitLossOfPointer,
+ slmfUnequippedHighOrderPathUnequipped,
+ slmfPLMHighOrderPathLabelMismatch,
+ rdiHighOrderRemoteDefectOrAlarmIndication,
+ lopTributaryUnitLossOfPointer,
+ aisTributaryUnitAlarmIndicationSignal,
+ slmfUnequippedLowOrderPathUnequipped,
+ slmfPLMLowOrderPathLabelMismatch,
+ timLowOrderTraceIdentifierMismatchFailure,
+ rfiLowOrderRemoteFailureOrAlarmIndication,
+ g811PrimaryReferenceClockTraceable,
+ g812TransitNodeClockTraceable,
+ g812LocalNodeClockTraceable,
+ g813SynchronousEquipmentTimingSourceTraceable,
+ e1LoopbackDueToFEACCommand,
+ e1LoopbackCommandSentToFarEnd,
+ e3LoopbackDueToFEACCommand,
+ farEndMultipleE1LOSDetectedOnE3,
+ farEndE1EqptFailNonServiceAffecting,
+ farEndE1EqptFailServiceAffecting,
+ farEndSingleE1LOS,
+ farEndE3EqptFailServiceAffecting,
+ e3LoopbackCommandSentToFarEnd,
+ farEndE3EqptFailNonServiceAffecting,
+ lowVoltBatteryA,
+ highVoltBatteryA,
+ lowVoltBatteryB,
+ highVoltBatteryB,
+ msspRingOutOfSync,
+ msspMultiNodeTableUpdateCompleted,
+ automaticSNCPSwitchCausedByAIS,
+ automaticSNCPSwitchCausedByLOP,
+ automaticSNCPSwitchCausedByUNEQ,
+ automaticSNCPSwitchCausedByPDI,
+ automaticSNCPSwitchCausedBySFBER,
+ automaticSNCPSwitchCausedBySDBER,
+ stmConcatenationError,
+ e3IdleCondition,
+ channelMSSPInconsistentAPSCode,
+ channelMSSPImproperAPSCodeAPS,
+ channelMSSPNodeIdMismatchAPS,
+ channelMSSPDefaultKAPS,
+ channelMSSPConnectionLossAPS,
+ minimumClockTraceableSDH,
+ lineIsInWaitToRestoreStateSDH,
+ berThresholdExceededForSignalDegradeHighOrder,
+ berThresholdExceededForSignalFailureHighOrder,
+ berThresholdExceededForSignalDegradeLowOrder,
+ berThresholdExceededForSignalFailureLowOrder,
+ failureToSwitchToProtectionHighOrderPath,
+ failureToSwitchToProtectionLowOrderPath,
+ a8b10bOutOfSync,
+ odukPMAlarmIndicationSignal,
+ otukAlarmIndicationSignal,
+ otukSMBackwardDefectIndication,
+ odukBackwardDefectIndication,
+ fecUncorrectedWord,
+ gccTerminationFailure,
+ otukIncomingAlignmentError,
+ odukLockedDefectPM,
+ lossOfMultiFrame,
+ odukOpenConnectionIndication,
+ payloadTypeIdentifierMismatch,
+ odukTrailTraceIdentifierMismatch,
+ otukTrailTraceIdentifierMismatch,
+ equipmentHighLaserBias,
+ equipmentHighLaserTemp,
+ equipmentHighLaserPeltier,
+ facilityHighRxPower,
+ equipmentHighTxPower,
+ equipmentHighTransceiverVoltage,
+ equipmentLowLaserBias,
+ equipmentLowLaserTemp,
+ equipmentLowLaserPeltier,
+ facilityLowRxPower,
+ equipmentLowTxPower,
+ equipmentLowTransceiverVoltage,
+ equipmentRxLocked,
+ equipmentSquelched,
+ equipmentTxLocked,
+ otukSignalFailure,
+ odukSignalFailure,
+ otukSignalDegrade,
+ odukSignalDegrade,
+ pluggablePortMissing,
+ pluggablePortRateMismatch,
+ pluggablePortSecurityCodeMismatch,
+ tciNotSelected,
+ tci1ClockFailure,
+ odukPMBackwardDefectIndication,
+ odukTCM1BackwardDefectIndication,
+ odukTCM2BackwardDefectIndication,
+ equipmentHighRxTemperature,
+ equipmentLowRxTemperature,
+ tci2ClockFailure,
+ equipmentWavelengthMismatch,
+ dspCommunicationFailure,
+ dspFailure,
+ laserApproachingEndOfLife,
+ crossconnectLoopback,
+ adminLogoutOfUser,
+ userLockedOut,
+ adminLockoutOfUser,
+ adminLockoutClear,
+ invalidLoginUsername,
+ securityInvalidLoginPassword,
+ securityInvalidLoginLockedOut,
+ securityInvalidLoginAlreadyLoggedOn,
+ loginOfUser,
+ automaticLogoutOfIdleUser,
+ logoutOfUser,
+ firewallHasBeenDisabled,
+ connectionEquipmentMismatch,
+ disableInactiveUser,
+ disableInactiveClear,
+ batteryFailure,
+ extremeHighVolt,
+ extremeLowVolt,
+ highVolt,
+ lowVolt,
+ suspendUser,
+ suspendUserClear,
+ lineDccTerminationFailure,
+ multiplexSectionDccTerminationFailure,
+ gigaBitEthernetOutOfSync,
+ sequenceMismatch,
+ lossOfAlignment,
+ outOfUseByAdministrativeCommand,
+ outOfUseTransportFailure,
+ vcatGroupDown,
+ vcatGroupDegraded,
+ vcatGroupIncomplete,
+ alarmIndicationSignalInTX,
+ remoteAlarmIndicationInTX,
+ kByteAPSChannelFailure,
+ apsInvalidMode,
+ ipAddressAlreadyInUseWithinTheSameDccArea,
+ nodeNameInUseWithinTheSameDccArea,
+ rearPanelEthernetLinkRemoved,
+ manualSwitchToProtectResultedInNoTrafficSwitch,
+ manualSwitchBackToWorkingResultedInNoTrafficSwitch,
+ forcedSwitchToProtectResultedInNoTrafficSwitch,
+ forcedSwitchBackToWorkingResultedInNoTrafficSwitch,
+ duplicateSerialNumberDetectedOnAPluggableEntity,
+ lossOfSignalForOpticalChannel,
+ encapsulationMismatchPath,
+ encapsulationMismatchVT,
+ encapsulationMismatchHighOrderPath,
+ encapsulationMismatchLowOrderPath,
+ gfpUserPayloadMismatch,
+ gfpFibreChannelDistanceExtensionMismatch,
+ gfpFibreChannelDistanceExtensionBufferStarvation,
+ gfpFibreChannelDistanceExtensionCreditStarvation,
+ gfpClientSignalFailDetected,
+ gfpLossOfFrameDelineation,
+ gfpExtensionHeaderMismatch,
+ lcasVcgMemberTxSideInAddState,
+ lcasVcgMemberTxSideInDnuState,
+ lcasControlWordCrcCheckFailure,
+ lcasVcgMemberRxSideInFailState,
+ signalLossOnDataInterface,
+ synchronizationLossOnDataInterface,
+ portFAIL,
+ unreachablePortTargetPower,
+ portAddPowerDegradeLow,
+ portAddPowerDegradeHigh,
+ portAddPowerFailLow,
+ portAddPowerFailHigh,
+ automaticWdmAnsFinished,
+ incomingOverheadSignalAbsent,
+ opticalSafetyRemoteInterlockOn,
+ automaticPowerControlCorrectionSkipped,
+ apcCannotSetValueDueToRangeLimits,
+ farEndManualSwitchBackToWorkingSpan,
+ farEndForcedSwitchBackToWorkingSpan,
+ universalTransponderModuleHardwareFailure,
+ universalTransponderModuleCommunicationFailure,
+ pluginModuleRangeSettingsMismatch,
+ automaticPowerControlTerminatedOnManualRequest,
+ oduk1AlarmIndicationSignal,
+ oduk2AlarmIndicationSignal,
+ oduk3AlarmIndicationSignal,
+ oduk4AlarmIndicationSignal,
+ temperatureReadingMismatchBetweenSCCards,
+ voltageReadingMismatchBetweenSCCards,
+ alarmsSuppressedonOutOfGroupVcatMember,
+ blsrSoftwareVersionMismatch,
+ optimized1Plus1ApsPrimaryFacility,
+ optimized1Plus1ApsPrimarySectionMismatch,
+ optimized1Plus1ApsInvalidPrimarySection,
+ compositeClockHighLineVoltage,
+ berThresholdExceededForSignalDegradeVt,
+ berThresholdExceededForSignalFailureVt,
+ spanLengthOutOfRange,
+ idleSignalCondition,
+ idleSignalConditionInTx,
+ vtPathTraceIdentifierMismatch,
+ lossOfFrameInTX,
+ provisioningMismatch,
+ sectionTraceIdentifierMismatch,
+ regeneratorSectionTraceIdentifierMismatch,
+ switchingMatrixModuleFailureWorking,
+ switchingMatrixModuleFailureProtect,
+ slotCommunicationDisabled,
+ sessionTimeLimitExpired,
+ userPasswordChangeRequired,
+ isisAdjacencyFailure,
+ msspSoftwareVersionMismatch,
+ remoteAuthenticationFailSeeAuditLog,
+ ringIsSquelchingStsTraffic,
+ ringIsSquelchingVtTraffic,
+ archiveOfAuditLogFailed,
+ rprWrapped,
+ shelfCommunicationFailure,
+ duplicatedShelfIdentifier,
+ softwareMismatch,
+ lmpFailure,
+ opticalTerminationIncomplete,
+ forwardDefectIndication,
+ payloadMissingIndication,
+ spanMeasurementCannotBePerformed,
+ ringIsSquelchingHighOrderTraffic,
+ ringIsSquelchingLowOrderTraffic,
+ badPacketCountExceedsThreshold,
+ linkLayerKeepAliveFailure,
+ autonegotiationRemoteFailureIndication,
+ trailSignalFail,
+ ds1LoopbackCommandSentToFarEnd,
+ multiplexSectionSignalDegraded,
+ multiplexSectionExcessiveErrors,
+ highOrderPathSignalDegraded,
+ highOrderPathExcessiveErrors,
+ lowOrderPathSignalDegraded,
+ lowOrderPathExcessiveErrors,
+ regeneratorSectionDccTerminationFailure,
+ networkMemoryPoolLow,
+ ospfRoutingTableOverflow,
+ autoLaserShutdownDisabled,
+ rprProtectionIsActive,
+ maxRPRStationNumberExceeded,
+ rprProtectionConfigurationMismatched,
+ reservedBandwidthLinkRateExceededOnRinglet0,
+ reservedBandwidthLinkRateExceededOnRinglet1,
+ rprInterfaceInPassThroughMode,
+ rprPeerNodeIsMissing,
+ rprRiFailure,
+ rprSignalFailure,
+ rprSignalDegrade,
+ interlinkFailure,
+ apcWrongGain,
+ rprSpanMismatch,
+ efmRemoteFaultIndicationCriticalEvent,
+ efmRemoteFaultIndicationDyingGasp,
+ efmRemoteFaultIndicationLinkFault,
+ efmLinkMonitoringErroredSymbolPeriodEvent,
+ efmLinkMonitoringErroredFrameEvent,
+ efmLinkMonitoringErroredFramePeriodEvent,
+ efmLinkMonitoringErroredFrameSecondsSummary,
+ efmRemoteLoopbackRequestFailed,
+ fastAutomaticProtectionSwitching,
+ fastAutomaticProtectionSwitchingConfigMismatch,
+ lcasSinkGroupError,
+ lcasVcgMemberRxSideInDnuState,
+ fcDistanceExtFuncNotEstablished,
+ nonCiscoPPMInserted,
+ unqualifiedPPMInserted,
+ ftaMismatch,
+ cardPortsUnableToProvideProtection,
+ lmpSignalDegrade,
+ lmpSignalFailure,
+ lmpUnallocatedDataLink,
+ frontPortLinkLoss,
+ bertEnbl,
+ bertSyncFail,
+ workQueueFull,
+ equipmentPowerFailureAtConnectorA,
+ equipmentPowerFailureAtConnectorB,
+ equipmentPowerFailureAtReturnConnectorA,
+ equipmentPowerFailureAtReturnConnectorB,
+ ospfHelloFail,
+ openIOSlots,
+ lossOfClockFromMateShelfController,
+ virtualLanAlarmIndicationSignal,
+ dcuLossFailure,
+ ochncMaintenance,
+ ramanLaserShutdown,
+ losOfRamanSignal,
+ mcastMacTableFull,
+ multicastMacAddressAliasing,
+ ramanPwrProtOn,
+ cppPeerNotResponding,
+ voaControlLoopDisableDueToExcessiveCounterPropagationLight,
+ wizardIsRunning,
+ ramanGainNotReached,
+ localFault,
+ remoteFault,
+ efmRemoteLoopbackConfigured,
+ efmPeerMissing,
+ eqptDegrade,
+ excessiveBackPropagation,
+ remoteMaintenanceEndPointIsDown,
+ crossConnectedCFMService,
+ cfmLoop,
+ cfmConfigurationError,
+ outOfChannelGroupBundle,
+ repNeighborAdjacencyFailure,
+ repLinkFlapping,
+ faultInREPSegment,
+ primaryREPEdgePortElected,
+ secondaryREPEdgePortElected,
+ stcnREPGenerated,
+ vlbREPActivated,
+ vlbREPTriggerSoakingDelayActive,
+ pprForwardDefectIndication,
+ pprBackwardDefectIndication,
+ pprCoordinatedMaintenance,
+ pprTriggerThresholdBERExceeded,
+ wanSyncloss,
+ laserShutdownDueToWavelengthDrift,
+ manualLaserRestart,
+ laserShutdownDueToNonCiscoPPMInserted,
+ ethernetOSCTerminationFailure,
+ enhancedRemoteFailureIndicationPathServer,
+ enhancedRemoteFailureIndicationPathConnectivity,
+ enhancedRemoteFailureIndicationPathPayload,
+ securityIntrusionDetPwd,
+ securityIntrusionDetUser,
+ backPanelFacilityLoopback,
+ backPanelTerminalLoopback,
+ trunkPayloadTypeMismatch,
+ invalidMuxponderConfiguration,
+ coolingProfileMismatch,
+ trunkOduAlarmIndicationSignal,
+ companionCardMissing,
+ masterKeyExchangeFailed,
+ powerConsumptionLimitHasCrossed,
+ controlPlaneUnverifiedClearedAlarmsPresent,
+ unitHighTemperature,
+ overTemperatureUnitProtected,
+ seqMismatchCount,
+ keyProgramOnAlteraFpgaFailed,
+ duplicateNodeControllerDetected,
+ restorationInProg,
+ ramanPumpsCalibrationProcedureIsRunning,
+ ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes,
+ odukTCM1AlarmIndicationSignal,
+ odukTCM2AlarmIndicationSignal,
+ odukLockedDefectTCM1,
+ odukLockedDefectTCM2,
+ otukLossOfFrame,
+ odukOpenConnectionIndicationTCM1,
+ odukOpenConnectionIndicationTCM2,
+ odukTrailTraceIdentifierMismatchTCM1,
+ odukTrailTraceIdentifierMismatchTCM2,
+ odukSignalFailureTCM1,
+ odukSignalFailureTCM2,
+ odukSignalDegradeTCM1,
+ odukSignalDegradeTCM2,
+ lossOfChannel,
+ fecMismatch,
+ timSectionMonitorTraceIdentifierMismatchFailure,
+ automaticLaserShutdown,
+ shutterInsertionLossVariationDegradeLow,
+ opticalChannelDeactivationFailure,
+ shutterInsertionLossVariationDegradeHigh,
+ networkTopologyIncomplete,
+ pluginModuleCommunicationFailure,
+ opticalNetworkTypeMismatch,
+ forcedSwitchToPrimaryReference,
+ forcedSwitchToSecondReference,
+ forcedSwitchToThirdReference,
+ forcedSwitchToInternalClock,
+ industrialHighTemperature,
+ opticalPowerDegradeLow,
+ automaticPowerControlFailure,
+ opticalPowerDegradeHigh,
+ automaticPowerControlDisabled,
+ opticalPowerFailureLow,
+ ringIdMismatch,
+ opticalPowerFailureHigh,
+ lossOfContinuity,
+ variableOpticalAttenuatorDegradeLow,
+ variableOpticalAttenuatorDegradeHigh,
+ variableOpticalAttenuatorFailureLow,
+ variableOpticalAttenuatorFailureHigh,
+ laserBiasDegrade,
+ laserBiasFailure,
+ laserTemperatureDegrade,
+ opticalAmplifierGainDegradeLow,
+ opticalAmplifierGainDegradeHigh,
+ opticalAmplifierGainFailureLow,
+ opticalAmplifierGainFailureHigh,
+ opticalChannelConnectionFailure,
+ opticalChannelIncomplete,
+ opticalChannelActivationFailure,
+ laserAutoPowerReduction,
+ caseTemperatureDegrade,
+ fiberTemperatureDegrade,
+ shutterOpen,
+ awgTemperatureDegrade,
+ awgTemperatureFailure,
+ awgOverTemperature,
+ opticalAmplifierInitialization,
+ awgWarmUp,
+ incSigloss,
+ incSyncloss,
+ incGfpOutOfFrame,
+ incGfpSigLoss,
+ incGfpSyncLoss,
+ bridgeAndRollHasOccurred,
+ bridgeAndRollIsPendingAValidSignal,
+ clockBusFailureTscA,
+ clockBusFailureTscB,
+ waitToRestore,
+ extremeHighVoltBatteryA,
+ extremeLowVoltBatteryA,
+ extremeHighVoltBatteryB,
+ extremeLowVoltBatteryB,
+ iosConfigCopyFailed,
+ iosConfigCopyInProgress,
+ iosConfigCopySuccess,
+ signalingUnableToSetupCircuit,
+ errorInStartupConfig,
+ noStartupConfig,
+ needToSaveRunningConfig,
+ invalidAlarm,
+ rsvpHelloFSMToNeighborDown,
+ securityInvalidLoginUsername,
+ databaseBackupFailed,
+ databaseRestoreFailed,
+ lmpHelloFSMToControlChannelDown,
+ lmpNeighborDiscoveryHasFailed,
+ auditLog80PercentFull,
+ moduleCommunicationFailure,
+ auditLog100PercentFullOldestRecordsWillBeLost,
+ standbyDatabaseOutOfSync,
+ redundantPowerCapabilityLost,
+ lofAdministrationUnitLossOfMultiFrame,
+ sdhSpanIsInWaitToRestoreState,
+ berThresholdExceededForSignalDegradeLine,
+ berThresholdExceededForSignalDegradePath,
+ berThresholdExceededForSignalFailureLine,
+ berThresholdExceededForSignalFailurePath,
+ unauthorizedIncomingSignalingRequest
+ }
+ STATUS current
+ DESCRIPTION
+ "The notifications for Cisco ONS 15454"
+ ::= { cerent454Groups 30 }
+
+-- This definition of group will move to a cerentCommon modules
+-- eventually.
+
+cerent454CommonGroup OBJECT-GROUP
+ OBJECTS {
+-- cerentNotificationCategory,
+ cerent454EnableNotification,
+ cerent454NodeTime,
+ cerent454SentNotifications,
+ cerent454LastChangeTime,
+ cerent454MultishelfEnabled
+ }
+ STATUS current
+ DESCRIPTION
+ "The objects for storing all the current alarms"
+ ::= { cerent454Groups 40 }
+
+-- This group covers for threshold display and TCA trap
+
+cerentThresholdGroup OBJECT-GROUP
+ OBJECTS {
+ cerent454ThresholdMonitorType,
+ cerent454ThresholdLocation,
+ cerent454ThresholdPeriod,
+ cerent454ThresholdSetValue,
+ cerent454ThresholdCurrentValue,
+ cerent454ThresholdDetectType
+ }
+ STATUS current
+ DESCRIPTION
+ "The objects for storing all the current alarms"
+ ::= { cerent454Groups 50 }
+
+event454DeprecatedGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ securityInvalidLoginUsernameSeeAuditTrail
+ }
+ STATUS deprecated
+ DESCRIPTION
+ "The notifications for Cisco ONS 15454 that have been deprecated"
+ ::= { cerent454Groups 60 }
+
+reportedAlarm454Group OBJECT-GROUP
+ OBJECTS {
+ cerent454ReportedAlarmCount,
+ cerent454ReportedAlarmObjectType,
+ cerent454ReportedAlarmSlotNumber,
+ cerent454ReportedAlarmPortNumber,
+ cerent454ReportedAlarmObjectIndex,
+ cerent454ReportedAlarmType,
+ cerent454ReportedAlarmTimeStamp,
+ cerent454ReportedAlarmObjectName,
+ cerent454ReportedAlarmAdditionalInfo,
+ cerent454ReportedAlarmSeverity,
+ cerent454ReportedAlarmStatus,
+ cerent454ReportedAlarmServiceAffecting
+ }
+ STATUS current
+ DESCRIPTION
+ "The group for reported alarm objects"
+ ::= { cerent454Groups 80 }
+
+
+-- the compliance specification for agent developers
+
+cerent454BasicCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The basic implementation requirements for Cisco ONS 15454 MIB"
+ MODULE
+ MANDATORY-GROUPS {
+ node454Group,
+ event454Group
+ }
+ ::= { cerent454Compliance 10 }
+