summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CTRON-UPS-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/enterasys/CTRON-UPS-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/enterasys/CTRON-UPS-MIB')
-rw-r--r--MIBS/enterasys/CTRON-UPS-MIB208
1 files changed, 208 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTRON-UPS-MIB b/MIBS/enterasys/CTRON-UPS-MIB
new file mode 100644
index 0000000..52b38c6
--- /dev/null
+++ b/MIBS/enterasys/CTRON-UPS-MIB
@@ -0,0 +1,208 @@
+CTRON-UPS-MIB DEFINITIONS ::= BEGIN
+
+ -- ctron-ups-mib.txt
+ -- Revision: 1.03.00
+ -- Part Number: 2170564
+ -- Date: May 1, 1996
+
+ -- Cabletron Systems, Inc.
+ -- 35 Industrial Way, P.O. Box 5005
+ -- Rochester, NH 03867-0505
+ -- (603) 332-9400
+ -- support@ctron.com
+
+ -- This module provides authoritative definitions for Cabletron's
+ -- enterprise-specific UPS MIB.
+ --
+ -- This module will be extended, as required.
+ --
+
+ -- Cabletron Systems reserves the right to make changes in
+ -- specification and other information contained in this document
+ -- without prior notice. The reader should consult Cabletron Systems
+ -- to determine whether any such changes have been made.
+ --
+ -- In no event shall Cabletron Systems be liable for any incidental,
+ -- indirect, special, or consequential damages whatsoever (including
+ -- but not limited to lost profits) arising out of or related to this
+ -- document or the information contained in it, even if Cabletron
+ -- Systems has been advised of, known, or should have known, the
+ -- possibility of such damages.
+ --
+ -- Cabletron grants vendors, end-users, and other interested parties
+ -- a non-exclusive license to use this Specification in connection
+ -- with the management of Cabletron products.
+
+ -- Copyright October 95 Cabletron Systems
+
+ -- This MIB is implemented whenever a uninterruptable power
+ -- supply is implemented.
+
+ IMPORTS
+ ctUPowerSupply FROM CTRON-MIB-NAMES
+ OBJECT-TYPE FROM RFC-1212;
+
+ ctUPS OBJECT IDENTIFIER ::= { ctUPowerSupply 1 }
+
+
+ -- The ups group
+
+ -- Implementation of this group is mandatory for devices that
+ -- incorporate uninterruptible power supplies.
+
+
+ ctUpsID OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ aPCModel370(257),
+ aPCModel400(258),
+ aPCModel600(259),
+ aPCModel900(260),
+ aPCModel1250(261),
+ aPCModel2000(262),
+ matrix3000(263),
+ matrix5000(264),
+ su700(265),
+ su1400(266),
+ su2000XL(267),
+ aPCGeneric(268) -- Generic APC for use when APC is not
+ -- otherwise defined.
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Denotes a type code which refers to the
+ manufacturers and model of the UPS."
+ ::= { ctUPS 1 }
+
+ ctUpsUpTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Denotes the operating time, in hours, since the UPS
+ was last powered on."
+ ::= { ctUPS 2 }
+
+ ctUpsDisable OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "Allows the UPS to be disabled. A set turns of the
+ UPS for those systems, so equipped. A get/get-next
+ always returns 0."
+ ::= { ctUPS 3 }
+
+ ctUpsDisconnect OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Allows the UPS backup power system to conserve its
+ battery. A set turns off the power system. A
+ get/get-next always returns a 0."
+ ::= { ctUPS 4 }
+
+ ctUpsTest OBJECT-TYPE
+ SYNTAX INTEGER {
+ unitOK(1),
+ unitFailed(2),
+ badBattery(3),
+ noRecentTest(4), -- no test performed in the last five
+ -- minutes
+ underTest(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Denotes the status performed on the UPS. A write
+ initiates the test. A read indicates status of
+ test."
+ ::= { ctUPS 5 }
+
+ ctUpsBatteryCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Denotes the percentage of battery capacity left,
+ 100% being a fully-charged battery."
+ ::= { ctUPS 6 }
+
+ ctUpsACLineVoltsIn OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Denotes the input AC utility line voltage."
+ ::= { ctUPS 7 }
+
+ ctUpsBatteryVoltsOut OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Denotes the battery voltage."
+ ::= { ctUPS 8 }
+
+ -- Enterprise specific trap definitions
+
+-- aPCLineFail OBJECT-TYPE
+-- ENTERPRISE cabletron
+-- DESCRIPTION
+-- "This trap is generated in the event of an AC
+-- utility line failure."
+-- ::= 0x1101
+--
+-- aPCLineFailRecovery OBJECT-TYPE
+-- ENTERPRISE cabletron
+-- DESCRIPTION
+-- "This trap is generated when the UPS switches back
+-- to line, and only if the aPCLineFail trap was issued
+-- first."
+-- ::= 0x1102
+--
+-- aPCLowBattery OBJECT-TYPE
+-- ENTERPRISE cabletron
+-- DESCRIPTION
+-- "This trap is generated in the event that the UPS'
+-- battery is found to be low."
+-- ::= 0x1103
+--
+-- aPCLowBatteryRecovery OBJECT-TYPE
+-- ENTERPRISE cabletron
+-- DESCRIPTION
+-- "This trap is generated when the UPS' battery has
+-- charged above the low-battery point, and only if the
+-- aPCLowBattery trap was issued first."
+-- ::= 0x1104
+--
+-- aPCAbnormalCondition OBJECT-TYPE
+-- ENTERPRISE cabletron
+-- DESCRIPTION
+-- "This trap is generated in the event that the UPS
+-- has entered an abnormal condition, such as an
+-- overload or trip on low battery. This trap is also
+-- sent, when the UPS is first turned on."
+-- ::= 0x1105
+--
+-- aPCAbnormalConditionRecovery OBJECT-TYPE
+-- ENTERPRISE cabletron
+-- DESCRIPTION
+-- "This trap is generated when the UPS has recovered
+-- from an abnormal condition, and only if the
+-- aPCAb-normalCondition trap was issued first."
+-- ::= 0x1106
+--
+-- aPCShuttingDown OBJECT-TYPE
+-- ENTERPRISE cabletron
+-- DESCRIPTION
+-- "This trap is generated in the event that the UPS
+-- has been ordered to shut itself, or the load, off
+-- over the serial line."
+-- ::= 0x1107
+--
+--
+
+END