diff options
Diffstat (limited to 'MIBS/enterasys/CTRON-UPS-MIB')
| -rw-r--r-- | MIBS/enterasys/CTRON-UPS-MIB | 208 |
1 files changed, 208 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTRON-UPS-MIB b/MIBS/enterasys/CTRON-UPS-MIB new file mode 100644 index 0000000..52b38c6 --- /dev/null +++ b/MIBS/enterasys/CTRON-UPS-MIB @@ -0,0 +1,208 @@ +CTRON-UPS-MIB DEFINITIONS ::= BEGIN + + -- ctron-ups-mib.txt + -- Revision: 1.03.00 + -- Part Number: 2170564 + -- Date: May 1, 1996 + + -- Cabletron Systems, Inc. + -- 35 Industrial Way, P.O. Box 5005 + -- Rochester, NH 03867-0505 + -- (603) 332-9400 + -- support@ctron.com + + -- This module provides authoritative definitions for Cabletron's + -- enterprise-specific UPS MIB. + -- + -- This module will be extended, as required. + -- + + -- Cabletron Systems reserves the right to make changes in + -- specification and other information contained in this document + -- without prior notice. The reader should consult Cabletron Systems + -- to determine whether any such changes have been made. + -- + -- In no event shall Cabletron Systems be liable for any incidental, + -- indirect, special, or consequential damages whatsoever (including + -- but not limited to lost profits) arising out of or related to this + -- document or the information contained in it, even if Cabletron + -- Systems has been advised of, known, or should have known, the + -- possibility of such damages. + -- + -- Cabletron grants vendors, end-users, and other interested parties + -- a non-exclusive license to use this Specification in connection + -- with the management of Cabletron products. + + -- Copyright October 95 Cabletron Systems + + -- This MIB is implemented whenever a uninterruptable power + -- supply is implemented. + + IMPORTS + ctUPowerSupply FROM CTRON-MIB-NAMES + OBJECT-TYPE FROM RFC-1212; + + ctUPS OBJECT IDENTIFIER ::= { ctUPowerSupply 1 } + + + -- The ups group + + -- Implementation of this group is mandatory for devices that + -- incorporate uninterruptible power supplies. + + + ctUpsID OBJECT-TYPE + SYNTAX INTEGER { + other(1), -- none of the following + aPCModel370(257), + aPCModel400(258), + aPCModel600(259), + aPCModel900(260), + aPCModel1250(261), + aPCModel2000(262), + matrix3000(263), + matrix5000(264), + su700(265), + su1400(266), + su2000XL(267), + aPCGeneric(268) -- Generic APC for use when APC is not + -- otherwise defined. + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Denotes a type code which refers to the + manufacturers and model of the UPS." + ::= { ctUPS 1 } + + ctUpsUpTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS deprecated + DESCRIPTION + "Denotes the operating time, in hours, since the UPS + was last powered on." + ::= { ctUPS 2 } + + ctUpsDisable OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS deprecated + DESCRIPTION + "Allows the UPS to be disabled. A set turns of the + UPS for those systems, so equipped. A get/get-next + always returns 0." + ::= { ctUPS 3 } + + ctUpsDisconnect OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Allows the UPS backup power system to conserve its + battery. A set turns off the power system. A + get/get-next always returns a 0." + ::= { ctUPS 4 } + + ctUpsTest OBJECT-TYPE + SYNTAX INTEGER { + unitOK(1), + unitFailed(2), + badBattery(3), + noRecentTest(4), -- no test performed in the last five + -- minutes + underTest(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Denotes the status performed on the UPS. A write + initiates the test. A read indicates status of + test." + ::= { ctUPS 5 } + + ctUpsBatteryCapacity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Denotes the percentage of battery capacity left, + 100% being a fully-charged battery." + ::= { ctUPS 6 } + + ctUpsACLineVoltsIn OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Denotes the input AC utility line voltage." + ::= { ctUPS 7 } + + ctUpsBatteryVoltsOut OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Denotes the battery voltage." + ::= { ctUPS 8 } + + -- Enterprise specific trap definitions + +-- aPCLineFail OBJECT-TYPE +-- ENTERPRISE cabletron +-- DESCRIPTION +-- "This trap is generated in the event of an AC +-- utility line failure." +-- ::= 0x1101 +-- +-- aPCLineFailRecovery OBJECT-TYPE +-- ENTERPRISE cabletron +-- DESCRIPTION +-- "This trap is generated when the UPS switches back +-- to line, and only if the aPCLineFail trap was issued +-- first." +-- ::= 0x1102 +-- +-- aPCLowBattery OBJECT-TYPE +-- ENTERPRISE cabletron +-- DESCRIPTION +-- "This trap is generated in the event that the UPS' +-- battery is found to be low." +-- ::= 0x1103 +-- +-- aPCLowBatteryRecovery OBJECT-TYPE +-- ENTERPRISE cabletron +-- DESCRIPTION +-- "This trap is generated when the UPS' battery has +-- charged above the low-battery point, and only if the +-- aPCLowBattery trap was issued first." +-- ::= 0x1104 +-- +-- aPCAbnormalCondition OBJECT-TYPE +-- ENTERPRISE cabletron +-- DESCRIPTION +-- "This trap is generated in the event that the UPS +-- has entered an abnormal condition, such as an +-- overload or trip on low battery. This trap is also +-- sent, when the UPS is first turned on." +-- ::= 0x1105 +-- +-- aPCAbnormalConditionRecovery OBJECT-TYPE +-- ENTERPRISE cabletron +-- DESCRIPTION +-- "This trap is generated when the UPS has recovered +-- from an abnormal condition, and only if the +-- aPCAb-normalCondition trap was issued first." +-- ::= 0x1106 +-- +-- aPCShuttingDown OBJECT-TYPE +-- ENTERPRISE cabletron +-- DESCRIPTION +-- "This trap is generated in the event that the UPS +-- has been ordered to shut itself, or the load, off +-- over the serial line." +-- ::= 0x1107 +-- +-- + +END |