diff --git a/MIBS/fs/STP-MIB b/MIBS/fs/STP-MIB new file mode 100644 index 0000000..6a4d1e2 --- /dev/null +++ b/MIBS/fs/STP-MIB @@ -0,0 +1,841 @@ +STP-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, Counter32, TimeTicks, OBJECT-TYPE, Integer32
+ FROM SNMPv2-SMI
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ gbnL2 FROM ADMIN-MASTER-MIB;
+
+
+ stpMib MODULE-IDENTITY
+ LAST-UPDATED "9904230031Z" -- April 23, 1999
+ ORGANIZATION "admin Inc."
+ CONTACT-INFO
+ "admin
+ E-mail: "
+
+ DESCRIPTION "STP module management."
+
+ REVISION "9905130000Z" -- May 13, 1999
+ DESCRIPTION "Initial Version"
+
+ ::= { gbnL2 3 }
+
+ stpMIBObjects OBJECT IDENTIFIER ::= { stpMib 1 }
+ stpDot1dStp OBJECT IDENTIFIER ::= { stpMIBObjects 1 }
+
+
+ -- All representations of MAC addresses in this MIB Module
+ -- use, as a textual convention (i.e. this convention does
+ -- not affect their encoding), the data type:
+
+ -- MacAddress ::= OCTET STRING (SIZE (6)) a 6 octet address
+ -- in the
+ -- "canonical"
+ -- order
+ -- defined by IEEE 802.1a, i.e., as if it were transmitted
+ -- least significant bit first, even though 802.5 (in
+ -- contrast to other n802.x protocols) requires MAC
+ -- addresses to be transmitted most significant bit first.
+ --
+ -- 16-bit addresses, if needed, are represented by setting
+ -- their upper 4 octets to all 0's, i.e., AAFF would be
+ -- represented as 00000000AAFF.
+
+
+ -- Similarly, all representations of Bridge-Id in this MIB
+ -- Module use, as a textual convention (i.e. this
+ -- convention does not affect their encoding), the data
+ -- type:
+
+ BridgeId ::= OCTET STRING (SIZE (8)) -- the
+ -- Bridge-Identifier
+ -- as used in the
+ -- Spanning Tree
+ -- Protocol to uniquely identify a bridge. Its first two
+ -- octets (in network byte order) contain a priority
+ -- value and its last 6 octets contain the MAC address
+ -- used to refer to a bridge in a unique fashion
+ -- (typically, the numerically smallest MAC address
+ -- of all ports on the bridge).
+ -- Several objects in this MIB module represent values of
+ -- timers used by the Spanning Tree Protocol. In this
+ -- MIB, these timers have values in units of hundreths of
+ -- a second (i.e. 1/100 secs).
+ -- These timers, when stored in a Spanning Tree Protocol's
+ -- BPDU, are in units of 1/256 seconds. Note, however,
+ -- that 802.1D-1990 specifies a settable granularity of
+ -- no more than 1 second for these timers. To avoid
+ -- ambiguity, a data type is defined here as a textual
+ -- convention and all representation of these timers
+ -- in this MIB module are defined using this data type. An
+ -- algorithm is also defined for converting between the
+ -- different units, to ensure a timer's value is not
+ -- distorted by multiple conversions.
+ -- The data type is:
+
+ Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds
+
+ -- To convert a Timeout value into a value in units of
+ -- 1/256 seconds, the following algorithm should be used:
+ --
+ -- b = floor( (n * 256) / 100)
+ --
+ -- where:
+ -- floor = quotient [ignore remainder]
+ -- n is the value in 1/100 second units
+ -- b is the value in 1/256 second units
+ --
+ -- To convert the value from 1/256 second units back to
+ -- 1/100 seconds, the following algorithm should be used:
+ --
+ -- n = ceiling( (b * 100) / 256)
+ --
+ -- where:
+ -- ceiling = quotient [if remainder is 0], or
+ -- quotient + 1 [if remainder is non-zero]
+ -- n is the value in 1/100 second units
+ -- b is the value in 1/256 second units
+ --
+ -- Note: it is important that the arithmetic operations are
+ -- done in the order specified (i.e., multiply first, divide
+ -- second).
+
+
+ -- the stpDot1dStp group
+
+ -- Implementation of the dot1dStp group is optional. It is
+ -- implemented by those bridges that support the Spanning Tree
+ -- Protocol.
+
+
+ stpDot1dStpProtocolSpecification OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ decLb100(2),
+ ieee8021d(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An indication of what version of the Spanning
+ Tree Protocol is being run. The value
+ 'decLb100(2)' indicates the DEC LANbridge 100
+ Spanning Tree protocol. IEEE 802.1d
+ implementations will return 'ieee8021d(3)'. If
+ future versions of the IEEE Spanning Tree Protocol
+ are released that are incompatible with the
+ current version a new value will be defined."
+ ::= { stpDot1dStp 1 }
+
+ stpDot1dStpPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..61440)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DURABLE: { 32768:all }
+ The value of the write-able portion of the Bridge
+ ID, i.e., the first two octets of the (8 octet
+ long) Bridge ID. The other (last) 6 octets of the
+ Bridge ID are given by the value of
+ dot1dBaseBridgeAddress.The value has to be a multiple
+ of 4096"
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.7"
+ ::= { stpDot1dStp 2 }
+
+ stpDot1dStpTimeSinceTopologyChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time (in hundredths of a second) since the
+ last time a topology change was detected by the
+ bridge entity."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 6.8.1.1.3"
+ ::= { stpDot1dStp 3 }
+
+ stpDot1dStpTopChanges OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of topology changes detected by
+ this bridge since the management entity was last
+ reset or initialized."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 6.8.1.1.3"
+ ::= { stpDot1dStp 4 }
+
+ stpDot1dStpDesignatedRoot OBJECT-TYPE
+ SYNTAX BridgeId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The bridge identifier of the root of the spanning
+ tree as determined by the Spanning Tree Protocol
+ as executed by this node. This value is used as
+ the Root Identifier parameter in all Configuration
+ Bridge PDUs originated by this node."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.1"
+ ::= { stpDot1dStp 5 }
+
+ stpDot1dStpRootCost OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The cost of the path to the root as seen from
+ this bridge."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.2"
+ ::= { stpDot1dStp 6 }
+
+ stpDot1dStpRootPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port number of the port which offers the
+ lowest cost path from this bridge to the root
+ bridge."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.3"
+ ::= { stpDot1dStp 7 }
+
+ stpDot1dStpMaxAge OBJECT-TYPE
+ SYNTAX Timeout (600..4000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum age of Spanning Tree Protocol
+ information learned from the network on any port
+ before it is discarded, in units of hundredths of
+ a second. This is the actual value that this
+ bridge is currently using."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.4"
+ ::= { stpDot1dStp 8 }
+
+ stpDot1dStpHelloTime OBJECT-TYPE
+ SYNTAX Timeout (100..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The amount of time between the transmission of
+ Configuration bridge PDUs by this node on any port
+ when it is the root of the spanning tree or trying
+ to become so, in units of hundredths of a second.
+ This is the actual value that this bridge is
+ currently using."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.5"
+ ::= { stpDot1dStp 9 }
+
+ stpDot1dStpHoldTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This time value determines the interval length
+ during which no more than two Configuration bridge
+ PDUs shall be transmitted by this node, in units
+ of hundredths of a second."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.14"
+ ::= { stpDot1dStp 10 }
+
+ stpDot1dStpForwardDelay OBJECT-TYPE
+ SYNTAX Timeout (400..3000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This time value, measured in units of hundredths
+ of a second, controls how fast a port changes its
+ spanning state when moving towards the Forwarding
+ state. The value determines how long the port
+ stays in each of the Listening and Learning
+ states, which precede the Forwarding state. This
+ value is also used, when a topology change has
+ been detected and is underway, to age all dynamic
+ entries in the Forwarding Database. [Note that
+ this value is the one that this bridge is
+ currently using, in contrast to
+ stpDot1dStpBridgeForwardDelay which is the value that
+ this bridge and all others would start using
+ if/when this bridge were to become the root.]"
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.6"
+ ::= { stpDot1dStp 11 }
+
+ stpDot1dStpBridgeMaxAge OBJECT-TYPE
+ SYNTAX Timeout (600..4000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DURABLE: { 2000:all }
+ The value that all bridges use for MaxAge when
+ this bridge is acting as the root. Note that
+ 802.1D-1990 specifies that the range for this
+ parameter is related to the value of
+ stpDot1dStpBridgeHelloTime. The granularity of this
+ timer is specified by 802.1D-1990 to be 1 second.
+ An agent may return a badValue error if a set is
+ attempted to a value which is not a whole number
+ of seconds."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.8"
+ ::= { stpDot1dStp 12 }
+
+ stpDot1dStpBridgeHelloTime OBJECT-TYPE
+ SYNTAX Timeout (100..1000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DURABLE: { 200:all }
+ The value that all bridges use for HelloTime when
+ this bridge is acting as the root. The
+ granularity of this timer is specified by 802.1D-
+ 1990 to be 1 second. An agent may return a
+ badValue error if a set is attempted to a value
+ which is not a whole number of seconds."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.9"
+ ::= { stpDot1dStp 13 }
+
+ stpDot1dStpBridgeForwardDelay OBJECT-TYPE
+ SYNTAX Timeout (400..3000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DURABLE: { 1500:all }
+ The value that all bridges use for ForwardDelay
+ when this bridge is acting as the root. Note that
+ 802.1D-1990 specifies that the range for this
+ parameter is related to the value of
+ stpDot1dStpBridgeMaxAge. The granularity of this
+ timer is specified by 802.1D-1990 to be 1 second.
+ An agent may return a badValue error if a set is
+ attempted to a value which is not a whole number
+ of seconds."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.3.10"
+ ::= { stpDot1dStp 14 }
+
+ stpPropStpEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DURABLE: { enabled:all }
+ The enabled/disabled status of STP for the bridge entity."
+ ::= { stpDot1dStp 16 }
+
+ -- The Spanning Tree Port Table
+
+ stpDot1dStpPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StpDot1dStpPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains port-specific information
+ for the Spanning Tree Protocol."
+ ::= { stpDot1dStp 15 }
+
+ stpDot1dStpPortEntry OBJECT-TYPE
+ SYNTAX StpDot1dStpPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of information maintained by every port
+ about the Spanning Tree Protocol state for that
+ port."
+ INDEX { stpDot1dStpPort }
+ ::= { stpDot1dStpPortTable 1 }
+
+ StpDot1dStpPortEntry ::=
+ SEQUENCE {
+ stpDot1dStpPort
+ INTEGER,
+ stpDot1dStpPortPriority
+ INTEGER,
+ stpDot1dStpPortState
+ INTEGER,
+ stpDot1dStpPortEnable
+ INTEGER,
+ stpDot1dStpPortPathCost
+ INTEGER,
+ stpDot1dStpPortDesignatedRoot
+ BridgeId,
+ stpDot1dStpPortDesignatedCost
+ Integer32,
+ stpDot1dStpPortDesignatedBridge
+ BridgeId,
+ stpDot1dStpPortDesignatedPort
+ OCTET STRING,
+ stpDot1dStpPortForwardTransitions
+ Counter32,
+ stpDot1dRemoteLoopDetect
+ INTEGER,
+ stpDot1wRstpPortTxHoldCount
+ INTEGER,
+ stpDot1wRstpPortOperP2p
+ INTEGER,
+ stpDot1wRstpPortOperEdge
+ INTEGER,
+ stpDot1wRstpPortMcheck
+ INTEGER,
+ stpDot1wRstpPortTxTcn
+ INTEGER,
+ stpDot1wRstpPortTxConfig
+ INTEGER,
+ stpDot1wRstpPortTxRstp
+ INTEGER,
+ stpDot1wRstpPortRxTcn
+ INTEGER,
+ stpDot1wRstpPortRxConfig
+ INTEGER,
+ stpDot1wRstpPortRxRstp
+ INTEGER,
+ stpDot1wRstpPortClear
+ INTEGER,
+ stpDot1wRstpPortAdminP2p
+ INTEGER,
+ stpDot1wRstpPortAdminEdge
+ INTEGER
+ }
+
+ stpDot1dStpPort OBJECT-TYPE
+ SYNTAX INTEGER (1..128)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port number of the port for which this entry
+ contains Spanning Tree Protocol management
+ information."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 6.8.2.1.2"
+ ::= { stpDot1dStpPortEntry 1 }
+
+ stpDot1dStpPortPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..240)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DURABLE: { 128:all }
+ The value of the priority field which is
+ contained in the first (in network byte order)
+ octet of the (2 octet long) Port ID. The other
+ octet of the Port ID is given by the value of
+ stpDot1dStpPort.The value has to be a multiple
+ of 16"
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.5.1"
+ ::= { stpDot1dStpPortEntry 2 }
+
+ stpDot1dStpPortState OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ blocking(2),
+ listening(3),
+ learning(4),
+ forwarding(5),
+ broken(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port's current state as defined by
+ application of the Spanning Tree Protocol. This
+ state controls what action a port takes on
+ reception of a frame. If the bridge has detected
+ a port that is malfunctioning it will place that
+ port into the broken(6) state. For ports which
+ are disabled (see stpDot1dStpPortEnable), this object
+ will have a value of disabled(1)."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.5.2"
+ ::= { stpDot1dStpPortEntry 3 }
+
+
+ stpDot1dStpPortEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The enabled/disabled status of the port."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.5.2"
+ ::= { stpDot1dStpPortEntry 4 }
+
+ stpDot1dStpPortPathCost OBJECT-TYPE
+ SYNTAX INTEGER (1..200000000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DURABLE: { 10:all }
+ The contribution of this port to the path cost of
+ paths towards the spanning tree root which include
+ this port. 802.1D-1990 recommends that the
+ default value of this parameter be in inverse
+ proportion to the speed of the attached LAN."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.5.3"
+ ::= { stpDot1dStpPortEntry 5 }
+
+ stpDot1dStpPortDesignatedRoot OBJECT-TYPE
+ SYNTAX BridgeId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unique Bridge Identifier of the Bridge
+ recorded as the Root in the Configuration BPDUs
+ transmitted by the Designated Bridge for the
+ segment to which the port is attached."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.5.4"
+ ::= { stpDot1dStpPortEntry 6 }
+
+ stpDot1dStpPortDesignatedCost OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The path cost of the Designated Port of the
+ segment connected to this port. This value is
+ compared to the Root Path Cost field in received
+ bridge PDUs."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.5.5"
+ ::= { stpDot1dStpPortEntry 7 }
+
+ stpDot1dStpPortDesignatedBridge OBJECT-TYPE
+ SYNTAX BridgeId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Bridge Identifier of the bridge which this
+ port considers to be the Designated Bridge for
+ this port's segment."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.5.6"
+ ::= { stpDot1dStpPortEntry 8 }
+
+ stpDot1dStpPortDesignatedPort OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (2))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Port Identifier of the port on the Designated
+ Bridge for this port's segment."
+ REFERENCE
+ "IEEE 802.1D-1990: Section 4.5.5.7"
+ ::= { stpDot1dStpPortEntry 9 }
+
+ stpDot1dStpPortForwardTransitions OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times this port has transitioned
+ from the Learning state to the Forwarding state."
+ ::= { stpDot1dStpPortEntry 10 }
+
+ stpDot1dRemoteLoopDetect OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The LOOP DETECT status of the port."
+ --端口私有生成树的开启/关闭状态
+ ::= { stpDot1dStpPortEntry 11 }
+
+ stpDot1wRstpPortTxHoldCount OBJECT-TYPE
+ SYNTAX INTEGER(1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum number of BPDUs allowed to be transmitted during per helloTime"
+ --端口在每个helloTime时间内允许发送的最大BPDU数
+ ::= { stpDot1dStpPortEntry 12 }
+
+ stpDot1wRstpPortOperP2p OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operational point-to-point status of the LAN segment attached to this port"
+ --端口实际工作的点对点链接状态
+ ::= { stpDot1dStpPortEntry 13 }
+
+ stpDot1wRstpPortOperEdge OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operational value of the Edge Port parameter"
+ --端口实际工作的边界端口状态
+ ::= { stpDot1dStpPortEntry 14 }
+
+ stpDot1wRstpPortMcheck OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "force port into transmitting rstp packets"
+ --强制端口发送RSTP报文
+ ::= { stpDot1dStpPortEntry 15 }
+
+ stpDot1wRstpPortTxTcn OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output statistics of TCN packets"
+ --端口发送的TCN报文个数
+ ::= { stpDot1dStpPortEntry 16 }
+
+ stpDot1wRstpPortTxConfig OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output statistics of CONFIG packets"
+ --端口发送的CONFIG报文个数
+ ::= { stpDot1dStpPortEntry 17 }
+
+ stpDot1wRstpPortTxRstp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output statistics of RSTP packets"
+ --端口发送的RSTP报文个数
+ ::= { stpDot1dStpPortEntry 18 }
+
+ stpDot1wRstpPortRxTcn OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input statistics of TCN packets"
+ --端口接收的TCN报文个数
+ ::= { stpDot1dStpPortEntry 19 }
+
+ stpDot1wRstpPortRxConfig OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input statistics of CONFIG packets"
+ --端口接收的CONFIG报文个数
+ ::= { stpDot1dStpPortEntry 20 }
+
+ stpDot1wRstpPortRxRstp OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input statistics of RSTP packets"
+ --端口接收的RSTP报文个数
+ ::= { stpDot1dStpPortEntry 21 }
+
+ stpDot1wRstpPortClear OBJECT-TYPE
+ SYNTAX INTEGER{
+ true(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Clear port spanning-tree statistics"
+ --清除端口生成树统计信息
+ ::= { stpDot1dStpPortEntry 22 }
+
+ stpDot1wRstpPortAdminP2p OBJECT-TYPE
+ SYNTAX INTEGER {
+ forceTrue(1),
+ forceFalse(2),
+ auto(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The administrative point-to-point status of the LAN segment attached to this port"
+ --配置的端口的点对点链接状态
+ ::= { stpDot1dStpPortEntry 23 }
+
+ stpDot1wRstpPortAdminEdge OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The administrative value of the Edge Port parameter"
+ --配置的边界端口状态
+ ::= { stpDot1dStpPortEntry 24 }
+
+ spanOnOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "DURABLE: { enable }
+ Enable/Disable Spanning Tree for the bridge.
+ When 'disable(2)', all ports of the device are placed in the
+ forwarding mode, regardless of current Spanning Tree state.
+ When 'enable(1)', the normal STP state transitions take place."
+ ::= { stpDot1dStp 17 }
+
+ stpDot1wRstpForceVersion OBJECT-TYPE
+ SYNTAX INTEGER {
+ ForceStp(0),
+ ForceRstp(2),
+ ForceMstp(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "which protocol mode the bridge chooses to execute ,RSTP or STP compatible"
+ --桥当前的协议模式,RSTP或者STP兼容模式
+ ::= { stpDot1dStp 19 }
+
+ stpDot1dStpTrap OBJECT IDENTIFIER ::= { stpDot1dStp 18 }
+ ----------------------------------------------------------------------------------
+ --STP TRAP MIB--
+ ----------------------------------------------------------------------------------
+
+ stpDot1dStpPortBlocking NOTIFICATION-TYPE
+ OBJECTS { stpDot1dStpPortState }
+ STATUS current
+ DESCRIPTION
+ "Port status is turned from forwarding to blocking."
+ ::= { stpDot1dStpTrap 1 }
+
+ stpDot1dStpPortException NOTIFICATION-TYPE
+ OBJECTS { stpDot1dStpPort }
+ STATUS current
+ DESCRIPTION
+ "Port packet flood to CPU rate is too big, port exception happen."
+ --如果端口冲击CPU的报文速率太大,则发出端口异常的trap
+ ::= { stpDot1dStpTrap 2 }
+
+ stpDot1dStpPortRecover NOTIFICATION-TYPE
+ OBJECTS { stpDot1dStpPort }
+ STATUS current
+ DESCRIPTION
+ "Port recover time pass after port encounter port CAR exception, and Port packet flood to CPU rate is normal, recover port."
+ --端口被端口CAR关闭后,过了端口恢复时间,并且该端口下冲击CPU的速率正常,重新打开端口,并发送端口恢复trap
+ ::= { stpDot1dStpTrap 3 }
+
+ stpDot1dStpPortRmtLoop NOTIFICATION-TYPE
+ OBJECTS { stpDot1dStpPort }
+ STATUS current
+ DESCRIPTION
+ "Port is blocked because of remote loop."
+ --端口因为远端环回而被block
+ ::= { stpDot1dStpTrap 4 }
+
+ stpDot1dStpPortRmtLoopFree NOTIFICATION-TYPE
+ OBJECTS { stpDot1dStpPort }
+ STATUS current
+ DESCRIPTION
+ "Port is released from remote loop."
+ --端口远端环回解除
+ ::= { stpDot1dStpTrap 5 }
+
+ stpDot1dStpNewRoot NOTIFICATION-TYPE
+ OBJECTS { stpDot1dStpDesignatedRoot }
+ STATUS current
+ DESCRIPTION
+ "Root bridge changed for the stp."
+ ::= { stpDot1dStpTrap 6 }
+
+ stpDot1dStpPortForwarding NOTIFICATION-TYPE
+ OBJECTS { stpDot1dStpPortState }
+ STATUS current
+ DESCRIPTION
+ "Port status is turned from blocking to forwarding."
+ ::= { stpDot1dStpTrap 7 }
+-- -----------------------------------------------------------------------------
+-- STP MIB - Conformance information
+-- Not really necessary other than for strict interpretation of SMIv2
+-- (and it doesn't hurt anything)
+-- -----------------------------------------------------------------------------
+stpMIBConformance OBJECT IDENTIFIER ::= { stpMib 2 }
+stpMIBGroups OBJECT IDENTIFIER ::= { stpMIBConformance 1 }
+stpMIBCompliances OBJECT IDENTIFIER ::= { stpMIBConformance 2 }
+
+ stpMIBBaseGroup OBJECT-GROUP
+ OBJECTS {
+ stpDot1dStpProtocolSpecification,
+ stpDot1dStpPriority,
+ stpDot1dStpTimeSinceTopologyChange,
+ stpDot1dStpTopChanges,
+ stpDot1dStpDesignatedRoot,
+ stpDot1dStpRootCost,
+ stpDot1dStpRootPort,
+ stpDot1dStpMaxAge,
+ stpDot1dStpHelloTime,
+ stpDot1dStpHoldTime,
+ stpDot1dStpForwardDelay,
+ stpDot1dStpBridgeMaxAge,
+ stpDot1dStpBridgeHelloTime,
+ stpDot1dStpBridgeForwardDelay,
+ stpPropStpEnable,
+ stpDot1dStpPort,
+ stpDot1dStpPortPriority,
+ stpDot1dStpPortState,
+ stpDot1dStpPortEnable,
+ stpDot1dStpPortPathCost,
+ stpDot1dStpPortDesignatedRoot,
+ stpDot1dStpPortDesignatedCost,
+ stpDot1dStpPortDesignatedBridge,
+ stpDot1dStpPortDesignatedPort,
+ stpDot1dStpPortForwardTransitions
+ }
+ STATUS current
+ DESCRIPTION
+ "STP module groups."
+ ::= { stpMIBGroups 1 }
+
+-- -----------------------------------------------------------------------------
+-- STP MIB - Compliance information
+-- -----------------------------------------------------------------------------
+ stpMIBCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for STP module."
+ MODULE
+ MANDATORY-GROUPS {
+ stpMIBBaseGroup
+ }
+ ::= { stpMIBCompliances 1 }
+
+END
+
+
|