diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/infinera/LUM-IFPERF-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/infinera/LUM-IFPERF-MIB')
| -rw-r--r-- | MIBS/infinera/LUM-IFPERF-MIB | 2874 |
1 files changed, 2874 insertions, 0 deletions
diff --git a/MIBS/infinera/LUM-IFPERF-MIB b/MIBS/infinera/LUM-IFPERF-MIB new file mode 100644 index 0000000..38955b4 --- /dev/null +++ b/MIBS/infinera/LUM-IFPERF-MIB @@ -0,0 +1,2874 @@ +LUM-IFPERF-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter64 + FROM SNMPv2-SMI + OBJECT-GROUP, MODULE-COMPLIANCE + FROM SNMPv2-CONF + TEXTUAL-CONVENTION, DateAndTime, DisplayString + FROM SNMPv2-TC + lumModules, lumIfPerfMIB + FROM LUM-REG + Unsigned32WithNA, MgmtNameString, AdminStatusWithNA, OperStatusWithNA, + ResetWithNA, OnOff, FaultStatusWithNA, Signed32WithNA, CommandString, TribPortIdType + FROM LUM-TC; + +lumIfPerfMIBModule MODULE-IDENTITY + LAST-UPDATED + "201906280000Z" -- June 28th 2019 + ORGANIZATION + "Infinera Corporation" + CONTACT-INFO + "techsupport@infinera.com" + DESCRIPTION + "The MIB module for management of performance objects. + + The tables contained in this MIB are: + + (1) The General group contains some general attributes as time stamps + and tables sizes. + + (2) The ifPerfAdmin performance group contains information and + configuration for all Admin performance objects + + (3) The ifPerfFec performance group contains information and + configuration for all Fec performance objects. + + (4) The ifPerfG826 performance group contains information and + configuration for all G826 performance objects. Notice table + is uni-directional meaning one entry for each direction. + + (5) The ifPerfL1 performance group contains information and + configuration for all L1 performance objects. Notice table + is uni-directional meaning one entry for each direction. + + (6) The ifPerfL0 performance group contains information and + configuration for all L0 performance objects. + + (7) The ifPerfL2 performance group contains information and + configuration for all L2 performance objects. + +" + REVISION + "201906280000Z" -- June 28th 2019 + DESCRIPTION + "Changes made for release r33.0: + - Added oa1x21dBmVgEC board + - Added oa2x21dBmVgEC board" + REVISION + "201903300000Z" -- March 30th 2019 + DESCRIPTION + "Changes made for release r32.1: + - Added ifPerfL0OpticalSNR + - Added ifPerfL0QFactor + - Added ifPerfFecQMargin + - Added ifPerfFecPreFecBer + - Added ifPerfL0OpticalSNR and ifPerfFecQMargin + - Added ifPerfG826TribPortId." + REVISION + "201706150000Z" -- June 15th 2017 + DESCRIPTION + "Changes made for release r29.0: + - Changed ORGANIZATION and CONTACT-INFO" + REVISION + "201611300000Z" -- November 30th 2016 + DESCRIPTION + "Changes made for release r28: + - Added tp100gotnii board." + REVISION + "201609300000Z" -- September 30th 2016 + DESCRIPTION + "Changes made for release r27.1: + - Added rfuac1 board." + REVISION + "201601110000Z" -- Jan 11th 2016 + DESCRIPTION + "Added default operStatus to notPresent." + REVISION + "201512220000Z" -- December 22nd 2015 + DESCRIPTION + "Changes made for release r27: + - Added fhau1 board + - Added fha1u1 board" + REVISION + "201511300000Z" -- Nov 30th 2015 + DESCRIPTION + "Changes made for release r26: + - Added attribute optical SNR." + REVISION + "201505290000Z" -- May 29th 2015 + DESCRIPTION + "Changes made for release r25: + - Added attribute FEC corrected bits. + - Added corresponding FEC RxBitErorrEstimate attribute as display string." + REVISION + "201409300000Z" -- September 30th 2014 + DESCRIPTION + "Changes made for release r23.1: + - Added mxp100gotn board." + REVISION + "201405160000Z" -- May 16th 2014 + DESCRIPTION + "Changes made for release r23: + - Added some L2 PM attributes + - Added some L0 PM attributes" + REVISION + "201311150000Z" -- November 15th 2013 + DESCRIPTION + "Changes made for release r22: + - Added tp10gotn, tp100gotn board. + - Added the L2 table + - Added Current Utilization attribute" + REVISION + "201305010000Z" -- May 1st 2013 + DESCRIPTION + "The initial revision of this module." + ::= { lumModules 56 } + + +PerfPeriodWithNA ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The period time for performance data. + + period15minutes - 15 minutes + period24hours - 24 hours" + + SYNTAX INTEGER { + period15minutes (1), + period24hours (2), + notApplicable (2147483647) } + + +G826MonitorLevelWithNA ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The monitor level." + + SYNTAX INTEGER { + opu0 (1), + odu0 (2), + otu0 (3), + opu1 (4), + odu1 (5), + otu1 (6), + opu2 (7), + odu2 (8), + otu2 (9), + opu3 (10), + odu3 (11), + otu3 (12), + opu4 (13), + odu4 (14), + otu4 (15), + oduFlex (16), + rs (17), + ms (18), + mac (19), + pcs (20), + cpriL1 (21), + obsaiL1 (22), + irsoh (23), + imsoh (24), + otuj2 (25), + opuFlex (26), + otuj1 (27), + notApplicable (2147483647) } + + +G826MonitorChannelWithNA ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The monitor channel." + + SYNTAX INTEGER { + unused (0), + sm (1), + pm (2), + tcm1 (3), + tcm2 (4), + tcm3 (5), + tcm4 (6), + tcm5 (7), + tcm6 (8), + notAvailable (2147483646), + notApplicable (2147483647) } + + +L1MeasurementTypeWithNA ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The direction type. + + rx - receiver, only ingoing signal + tx - transmitter, only outgoing signal" + + SYNTAX INTEGER { + rx (1), + tx (2), + notApplicable (2147483647) } + +L2MeasurementTypeWithNA ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The direction type. + + rx - receiver, only ingoing signal + tx - transmitter, only outgoing signal" + + SYNTAX INTEGER { + rx (1), + tx (2), + notApplicable (2147483647) } + + +G826MeasurementTypeWithNA ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The direction type. + + rx - receiver, only ingoing signal + tx - transmitter, only outgoing signal + uniDi - unidirectional + biDi - bidirectional, ingoing and outgoing signal on the same port" + + SYNTAX INTEGER { + rx (1), + tx (2), + uniDi (3), + biDi (4), + notApplicable (2147483647) } + +BooleanValueWithNA ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Defines a value that can be true, false or not available + + true - The condition is true + + false - The condition is false + + notAvailable (2147483646) is used when attribute is + not available under current circumstances. This value + is only used when used for a state. + + notApplicable (2147483647) is used when attribute is + not used in current configuration." + + SYNTAX INTEGER { + true (1), + false (2), + notAvailable (2147483646), + notApplicable (2147483647) } + + +-- ---------------------------------------------------- +-- Compliance area, containing groups and compliance +-- specifications. +-- ---------------------------------------------------- + +lumIfPerfConfs OBJECT IDENTIFIER ::= { lumIfPerfMIB 1 } +lumIfPerfGroups OBJECT IDENTIFIER ::= { lumIfPerfConfs 1 } +lumIfPerfCompl OBJECT IDENTIFIER ::= { lumIfPerfConfs 2 } + + +-- ---------------------------------------------------- +-- Root for objects in the IFPERF MIB +-- ---------------------------------------------------- + +lumIfPerfMIBObjects OBJECT IDENTIFIER ::= { lumIfPerfMIB 2 } + + +-- ---------------------------------------------------- +-- This MIB contains the following groups: +-- ---------------------------------------------------- + +ifPerfGeneral OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 1 } +ifPerfAdminList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 2 } +ifPerfFecList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 3 } +ifPerfG826List OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 4 } +ifPerfL1List OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 5 } +ifPerfL0List OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 6 } +ifPerfL2StatList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 7 } +ifPerfL2ErrorList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 8 } +ifPerfDelayList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 9 } + +-- ---------------------------------------------------- +-- General group +-- ---------------------------------------------------- + + +ifPerfGeneralConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the MIB was + last changed. + +" + ::= { ifPerfGeneral 1 } + +ifPerfGeneralStateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the MIB was last changed. + +" + ::= { ifPerfGeneral 2 } + +ifPerfGeneralAdminTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of ifPerfAdmin performance table. + +" + ::= { ifPerfGeneral 3 } + +ifPerfGeneralAdminConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the table was + last changed. + +" + ::= { ifPerfGeneral 4 } + +ifPerfGeneralAdminStateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the table was last changed. + +" + ::= { ifPerfGeneral 5 } + +ifPerfGeneralFecTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of ifPerfFec performance table. + +" + ::= { ifPerfGeneral 6 } + +ifPerfGeneralFecConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the table was + last changed. + +" + ::= { ifPerfGeneral 7 } + +ifPerfGeneralFecStateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the table was last changed. + +" + ::= { ifPerfGeneral 8 } + +ifPerfGeneralG826TableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of ifPerfG826 performance table. + +" + ::= { ifPerfGeneral 9 } + +ifPerfGeneralG826ConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the table was + last changed. + +" + ::= { ifPerfGeneral 10 } + +ifPerfGeneralG826StateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the table was last changed. + +" + ::= { ifPerfGeneral 11 } + +ifPerfGeneralL1TableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of ifPerfL1 performance table. + +" + ::= { ifPerfGeneral 12 } + +ifPerfGeneralL1ConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the table was + last changed. + +" + ::= { ifPerfGeneral 13 } + +ifPerfGeneralL1StateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the table was last changed. + +" + ::= { ifPerfGeneral 14 } + +ifPerfGeneralL0TableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of ifPerfL0 performance table. + +" + ::= { ifPerfGeneral 15 } + +ifPerfGeneralL0ConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the table was + last changed. + +" + ::= { ifPerfGeneral 16 } + +ifPerfGeneralL0StateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the table was last changed. + +" + ::= { ifPerfGeneral 17 } + +ifPerfGeneralL2StatTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of ifPerfL0 performance table. + +" + ::= { ifPerfGeneral 18 } + +ifPerfGeneralL2StatConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the table was + last changed. + +" + ::= { ifPerfGeneral 19 } + +ifPerfGeneralL2StatStateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the table was last changed. + +" + ::= { ifPerfGeneral 20 } + +ifPerfGeneralL2ErrorTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of ifPerfL0 performance table. + +" + ::= { ifPerfGeneral 21 } + +ifPerfGeneralL2ErrorConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the table was + last changed. + +" + ::= { ifPerfGeneral 22 } + +ifPerfGeneralL2ErrorStateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the table was last changed. + +" + ::= { ifPerfGeneral 23 } + +ifPerfGeneralDelayTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of ifPerfDelay performance table. + +" + ::= { ifPerfGeneral 24 } + +ifPerfGeneralDelayConfigLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the table was + last changed. + +" + ::= { ifPerfGeneral 25 } + +ifPerfGeneralDelayStateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state and/or configuration of + the table was last changed. + +" + ::= { ifPerfGeneral 26 } + +-- ---------------------------------------------------- +-- IfPerfAdmin admin group +-- ---------------------------------------------------- + +ifPerfAdminTable OBJECT-TYPE + SYNTAX SEQUENCE OF IfPerfAdminEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifPerfAdmin performance group contains information and + configuration for all ifPerfAdmin performance objects." + + ::= { ifPerfAdminList 1 } + +ifPerfAdminEntry OBJECT-TYPE + SYNTAX IfPerfAdminEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the ifPerfAdmin list. + +" + INDEX { ifPerfAdminIndex } + ::= { ifPerfAdminTable 1 } + +IfPerfAdminEntry ::= + SEQUENCE { + ifPerfAdminIndex Unsigned32, + ifPerfAdminName MgmtNameString, + ifPerfAdminConnIfBasicIfIndex Unsigned32WithNA, + ifPerfAdminAdminStatus AdminStatusWithNA, + ifPerfAdminReportMode OnOff, + ifPerfAdminOperStatus OperStatusWithNA, + ifPerfAdminIsSuspect15m BooleanValueWithNA, + ifPerfAdminIsSuspect24h BooleanValueWithNA, + ifPerfAdminReset15m ResetWithNA, + ifPerfAdminReset24h ResetWithNA, + ifPerfAdminUpId Unsigned32 } + +ifPerfAdminIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index assigned to each entry. + +" + ::= { ifPerfAdminEntry 1 } + + +ifPerfAdminName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The management name of the performance object, + for example 'lineAdmin:1:2:1-2', where the first number indicates + subrack, the second slot number and the third/fourth + are the physical port numbers. + +" + ::= { ifPerfAdminEntry 2 } + +ifPerfAdminConnIfBasicIfIndex OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "An index that describes to which index in ifBasicIf table + this object is related. + +" + ::= { ifPerfAdminEntry 3 } + +ifPerfAdminAdminStatus OBJECT-TYPE + SYNTAX AdminStatusWithNA + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The administrative state of the ifPerf interface. + + down - The interface is de-activated. + + service - The interface is activated. + + up - The interface will be activated when + available. + +" + DEFVAL { up } + ::= { ifPerfAdminEntry 4 } + +ifPerfAdminReportMode OBJECT-TYPE + SYNTAX OnOff + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The performance reporting mode on the interface. + + off - performance reporting is inactive. + + on - performance reporting is activated. + +" + DEFVAL { on } + ::= { ifPerfAdminEntry 5 } + +ifPerfAdminOperStatus OBJECT-TYPE + SYNTAX OperStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational state for the interface. + + notPresent - The interface is not available. + + down - The interface is de-activated or there are + faults preventing its transition to the 'up' state. + + up - The interface is active. + +" + DEFVAL { notPresent } + ::= { ifPerfAdminEntry 6 } + +ifPerfAdminIsSuspect15m OBJECT-TYPE + SYNTAX BooleanValueWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This variable indicates if the performance data is + unreliable for the 15 minute interval. The 'isSuspect' + value is set to true if the interface has + been reconfigured or reset during the maintenance + operation. For example if + - a full interval has not passed since last reset + - the board has been restarted during the interval + - adminStatus has been set to down + - the system time has been set in the node during the interval. + +" + ::= { ifPerfAdminEntry 7 } + +ifPerfAdminIsSuspect24h OBJECT-TYPE + SYNTAX BooleanValueWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This variable indicates if the performance data is + unreliable for the 24 hour interval. The 'isSuspect' + value is set to true if the interface has + been reconfigured or reset during the maintenance + operation. For example if + - a full interval has not passed since last reset + - the board has been restarted during the interval + - adminStatus has been set to down + - the system time has been set in the node during the interval. + +" + ::= { ifPerfAdminEntry 8 } + +ifPerfAdminReset15m OBJECT-TYPE + SYNTAX ResetWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Reset all performance counters for the 15 minute interval. + After a successful reset the default value + (normal) is restored in this attribute. + +" + DEFVAL { normal } + ::= { ifPerfAdminEntry 9 } + +ifPerfAdminReset24h OBJECT-TYPE + SYNTAX ResetWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Reset performance counters for the 24 hour interval. + After a successful reset the default value + (normal) is restored in this attribute. + + notApplicable (2147483647) is used when attribute is + not used in current configuration. + +" + DEFVAL { normal } + ::= { ifPerfAdminEntry 10 } + +ifPerfAdminUpId OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identity in the UP for the Perf Admin entry +" + DEFVAL { 0 } + ::= { ifPerfAdminEntry 11 } + +-- ---------------------------------------------------- +-- IfPerfFec fec group +-- ---------------------------------------------------- + +ifPerfFecTable OBJECT-TYPE + SYNTAX SEQUENCE OF IfPerfFecEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifPerfFec performance group contains information and + configuration for all ifPerfFec performance objects." + + ::= { ifPerfFecList 1 } + +ifPerfFecEntry OBJECT-TYPE + SYNTAX IfPerfFecEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the ifPerfFec list. + +" + INDEX { ifPerfFecIndex } + ::= { ifPerfFecTable 1 } + +IfPerfFecEntry ::= + SEQUENCE { + ifPerfFecIndex Unsigned32, + ifPerfFecName MgmtNameString, + ifPerfFecConnIfPerfAdminIfIndex Unsigned32WithNA, + ifPerfFecCorrectedZeros Unsigned32WithNA, + ifPerfFecCorrectedOnes Unsigned32WithNA, + ifPerfFecRxBerEstimation Unsigned32WithNA, + ifPerfFecRxAvgPreFecBer Unsigned32WithNA, + ifPerfFecCorrectedBits Unsigned32WithNA, + ifPerfFecRxBitErrorEstimation DisplayString, + ifPerfFecOpticalSNR Unsigned32WithNA, + ifPerfFecUpId Unsigned32, + ifPerfFecQMargin Unsigned32WithNA, + ifPerfFecPreFecBer DisplayString } + +ifPerfFecIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index assigned to each entry. + +" + ::= { ifPerfFecEntry 1 } + +ifPerfFecName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The management name of the performance object, + for example 'lineFec:1:2:1-2', where the first number indicates + subrack, the second slot number and the third/fourth + are the physical port numbers. + +" + ::= { ifPerfFecEntry 2 } + +ifPerfFecConnIfPerfAdminIfIndex OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "An index that describes to which index in ifPerfAdminIf table + this object is related. + +" + ::= { ifPerfFecEntry 3 } + +ifPerfFecCorrectedZeros OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "FEC counter. Number of corrected zeros. + +" + ::= { ifPerfFecEntry 4 } + +ifPerfFecCorrectedOnes OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "FEC counter. Number of corrected ones. + +" + ::= { ifPerfFecEntry 5 } + +ifPerfFecRxBerEstimation OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rx Bit Error Rate estimation. + +" + ::= { ifPerfFecEntry 6 } + +ifPerfFecRxAvgPreFecBer OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rx Average Pre FEC Bit Error Rate of PM interval. + +" + ::= { ifPerfFecEntry 7 } + +ifPerfFecCorrectedBits OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "FEC counter. Number of corrected bits. + +" + ::= { ifPerfFecEntry 8 } + +ifPerfFecRxBitErrorEstimation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rx Bit Error Rate estimation. + +" + DEFVAL { " " } + ::= { ifPerfFecEntry 9 } + +ifPerfFecOpticalSNR OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Optical signal-to-noise ratio margin (dB/0.1nm) with respect to FEC cliff, based on calculation from rate of corrected bits. + +" + ::= { ifPerfFecEntry 10 } + +ifPerfFecUpId OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identity in the UP for the Perf Admin entry + +" + DEFVAL { 0 } + ::= { ifPerfFecEntry 11 } + +ifPerfFecQMargin OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Q factor margin (dB) with respect to the FEC threshold. + +" + ::= { ifPerfFecEntry 12 } + +ifPerfFecPreFecBer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Pre-FEC BER. + +" + DEFVAL { "" } + ::= { ifPerfFecEntry 13 } + +-- ---------------------------------------------------- +-- IfPerfG826 g826 group +-- ---------------------------------------------------- + +ifPerfG826Table OBJECT-TYPE + SYNTAX SEQUENCE OF IfPerfG826Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifPerfG826 performance group contains information and + configuration for all ifPerfG826 performance objects. Notice table + is uni-directional meaning one entry for each direction." + + ::= { ifPerfG826List 1 } + +ifPerfG826Entry OBJECT-TYPE + SYNTAX IfPerfG826Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the ifPerfG826 list. + + +" + INDEX { ifPerfG826Index } + ::= { ifPerfG826Table 1 } + +IfPerfG826Entry ::= + SEQUENCE { + ifPerfG826Index Unsigned32, + ifPerfG826Name MgmtNameString, + ifPerfG826ConnIfPerfAdminIfIndex Unsigned32WithNA, + ifPerfG826Period PerfPeriodWithNA, + ifPerfG826Type G826MeasurementTypeWithNA, + ifPerfG826MonitorLevel G826MonitorLevelWithNA, + ifPerfG826MonitorChannel G826MonitorChannelWithNA, + ifPerfG826CounterEs Unsigned32WithNA, + ifPerfG826CounterSes Unsigned32WithNA, + ifPerfG826CounterUas Unsigned32WithNA, + ifPerfG826CounterBbe Counter64, + ifPerfG826ThresholdEs Unsigned32WithNA, + ifPerfG826ThresholdSes Unsigned32WithNA, + ifPerfG826ThresholdUas Unsigned32WithNA, + ifPerfG826ThresholdBbe Counter64, + ifPerfG826FaultStatusEs FaultStatusWithNA, + ifPerfG826FaultStatusSes FaultStatusWithNA, + ifPerfG826FaultStatusUas FaultStatusWithNA, + ifPerfG826FaultStatusBbe FaultStatusWithNA, + ifPerfG826UpId Unsigned32, + ifPerfG826TribPortId TribPortIdType } + +ifPerfG826Index OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index assigned to each entry. + +" + ::= { ifPerfG826Entry 1 } + +ifPerfG826Name OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The management name of the performance object, + for example 'lineG826OtsOtu2SmUni15m:1:2:23-24', + where the textual part indicates the hierarchy and type + line/client + G826 + OTS/OTUk/ODUk/OPUk/RS/MS/MAC/PCS etc or any combination thereof + SM/PM/TCMn monitor channel type, no monitor type is also possible + Rx/Tx/Uni/Bi direction type + 15m/24h time period, 15 minutes or 24 hours + + For the part after the colon the first number indicates + subrack, the second slot number and the third/fourth + are the physical port numbers. + +" + ::= { ifPerfG826Entry 2 } + +ifPerfG826ConnIfPerfAdminIfIndex OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "An index that describes to which index in ifPerfAdminIf table + this object is related. + +" + ::= { ifPerfG826Entry 3 } + +ifPerfG826Period OBJECT-TYPE + SYNTAX PerfPeriodWithNA + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Period, 15 minute or 24 hour. + - 15 minute interval measurements per + measurement point + + - 24 hour interval measurements per + measurement point + +" + ::= { ifPerfG826Entry 4 } + +ifPerfG826Type OBJECT-TYPE + SYNTAX G826MeasurementTypeWithNA + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The direction type of signal the interface expects. + + rx - Only ingoing signal. + + tx - Only outgoing signal. + + uniDi - Unidirectional signal. + + biDi - Ingoing and outgoing signal on the same + port. + +" + ::= { ifPerfG826Entry 5 } + +ifPerfG826MonitorLevel OBJECT-TYPE + SYNTAX G826MonitorLevelWithNA + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Monitor level, e.g. OPUk, ODUk, OTUk, RS, MS, MAC, PCS. + +" + ::= { ifPerfG826Entry 6 } + +ifPerfG826MonitorChannel OBJECT-TYPE + SYNTAX G826MonitorChannelWithNA + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Monitor channel, e.g. SM, PM, TCM1-6. + +" + ::= { ifPerfG826Entry 7 } + +ifPerfG826CounterEs OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Errored Seconds. + The counter associated with the number of + errored seconds in the interval specified by the + period attribute. + +" + ::= { ifPerfG826Entry 8 } + +ifPerfG826CounterSes OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Severely Errored Seconds. + The counter associated with the number of + severely errored seconds in the interval specified + by the period attribute. + +" + ::= { ifPerfG826Entry 9 } + +ifPerfG826CounterUas OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unavailable Seconds. + The counter associated with the number of + unavailable seconds in the interval specified + by the period attribute. + +" + ::= { ifPerfG826Entry 10 } + +ifPerfG826CounterBbe OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background Block Errors. + The counter associated with the number of + background block errors in the interval specified + by the period attribute. + +" + ::= { ifPerfG826Entry 11 } + +ifPerfG826ThresholdEs OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the threshold in seconds for the + errored seconds alarm. + + Range 15m: 0 to 900 seconds + 24h: 0 to 86400 seconds + +" + DEFVAL { 20 } + ::= { ifPerfG826Entry 12 } + +ifPerfG826ThresholdSes OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the threshold in seconds for the + severely errored seconds alarm. + + Range 15m: 0 to 900 seconds + 24h: 0 to 86400 seconds + +" + DEFVAL { 10 } + ::= { ifPerfG826Entry 13 } + +ifPerfG826ThresholdUas OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the threshold in seconds for the + unavailable seconds alarm. + + Range 15m: 0 to 900 seconds + 24h: 0 to 86400 seconds + +" + DEFVAL { 30 } + ::= { ifPerfG826Entry 14 } + +ifPerfG826ThresholdBbe OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the threshold for the + background block errors alarms. + +" + DEFVAL { 100000 } + ::= { ifPerfG826Entry 15 } + +ifPerfG826FaultStatusEs OBJECT-TYPE + SYNTAX FaultStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Errored Seconds threshold exceeded. + + alarm: The number of errors during a period + exceeds the associated threshold. + + ok: The number of errored seconds during a + period is below the threshold. + +" + ::= { ifPerfG826Entry 16 } + +ifPerfG826FaultStatusSes OBJECT-TYPE + SYNTAX FaultStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Severely Errored Seconds threshold exceeded. + + alarm: The number of severely errored seconds + during a period exceeds the associated threshold. + + ok: The number of severely errored seconds during + a period is below the threshold. + +" + ::= { ifPerfG826Entry 17 } + +ifPerfG826FaultStatusUas OBJECT-TYPE + SYNTAX FaultStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unavailable Seconds threshold exceeded. + + alarm: The number of unavailable seconds during + a period exceeds the associated threshold. + + ok: The number of unavailable seconds during a + period is below the threshold. + +" + ::= { ifPerfG826Entry 18 } + +ifPerfG826FaultStatusBbe OBJECT-TYPE + SYNTAX FaultStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Background Block Errors threshold exceeded. + + alarm: The number of background block errors + during a period exceeds the associated threshold. + + ok: The number of background block errors during + a period is below the threshold. + +" + ::= { ifPerfG826Entry 19 } + +ifPerfG826UpId OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identity in the UP for the Perf Admin entry + +" + DEFVAL { 0 } + ::= { ifPerfG826Entry 20 } + +ifPerfG826TribPortId OBJECT-TYPE + SYNTAX TribPortIdType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Tributary port id that describes to which high-order + tributary port this object belong to. + +" + DEFVAL { 0 } + ::= { ifPerfG826Entry 21 } + +-- ---------------------------------------------------- +-- IfPerfL1 l1 group +-- ---------------------------------------------------- + +ifPerfL1Table OBJECT-TYPE + SYNTAX SEQUENCE OF IfPerfL1Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifPerfL1 performance group contains information and + configuration for all ifPerfL1 performance objects. Notice table + is uni-directional meaning one entry for each direction." + + ::= { ifPerfL1List 1 } + +ifPerfL1Entry OBJECT-TYPE + SYNTAX IfPerfL1Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the ifPerfL1 list. + +" + INDEX { ifPerfL1Index } + ::= { ifPerfL1Table 1 } + +IfPerfL1Entry ::= + SEQUENCE { + ifPerfL1Index Unsigned32, + ifPerfL1Name MgmtNameString, + ifPerfL1ConnIfPerfAdminIfIndex Unsigned32WithNA, + ifPerfL1Period PerfPeriodWithNA, + ifPerfL1Type L1MeasurementTypeWithNA, + ifPerfL1MaxUtilization Unsigned32WithNA, + ifPerfL1AverageUtilization Unsigned32WithNA, + ifPerfL1CurrentUtilization Unsigned32WithNA } + +ifPerfL1Index OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index assigned to each entry. + +" + ::= { ifPerfL1Entry 1 } + +ifPerfL1Name OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The management name of the performance object, + for example 'clientL1Rx15m:1:2:1-2', + where the textual part indicates the type + line/client + L1 + Rx/Tx/Uni/Bi direction type + 15m/24h time period, 15 minutes or 24 hours + + For the part after the colon the first number indicates + subrack, the second slot number and the third/fourth + are the physical port numbers. + +" + ::= { ifPerfL1Entry 2 } + +ifPerfL1ConnIfPerfAdminIfIndex OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that describes to which index in ifPerfAdminIf table + this object is related. + +" + ::= { ifPerfL1Entry 3 } + +ifPerfL1Period OBJECT-TYPE + SYNTAX PerfPeriodWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Period, 15 minute or 24 hour. + - 15 minute interval measurements per + measurement point + + - 24 hour interval measurements per + measurement point + +" + ::= { ifPerfL1Entry 4 } + +ifPerfL1Type OBJECT-TYPE + SYNTAX L1MeasurementTypeWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The direction type of signal the interface expects. + + rx - Only ingoing signal. + + tx - Only outgoing signal. + +" + ::= { ifPerfL1Entry 5 } + +ifPerfL1MaxUtilization OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum bandwidth utilization of the received or + transmitted signal during a particular 15 minute or + 24 hour interval. + +" + ::= { ifPerfL1Entry 6 } + +ifPerfL1AverageUtilization OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bandwidth utilization of the received or + transmitted signal during a particular 15 minute or + 24 hour interval. + +" + ::= { ifPerfL1Entry 7 } + +ifPerfL1CurrentUtilization OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Current bandwidth utilization of the received or + transmitted signal during a particular 15 minute or + 24 hour interval. + +" + ::= { ifPerfL1Entry 8 } + +-- ---------------------------------------------------- +-- IfPerfL0 l0 group +-- ---------------------------------------------------- + +ifPerfL0Table OBJECT-TYPE + SYNTAX SEQUENCE OF IfPerfL0Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifPerfL0 performance group contains information and + configuration for all ifPerfL0 performance objects." + + ::= { ifPerfL0List 1 } + +ifPerfL0Entry OBJECT-TYPE + SYNTAX IfPerfL0Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the ifPerfL0 list. + +" + INDEX { ifPerfL0Index } + ::= { ifPerfL0Table 1 } + +IfPerfL0Entry ::= + SEQUENCE { + ifPerfL0Index Unsigned32, + ifPerfL0Name MgmtNameString, + ifPerfL0ConnIfPerfAdminIfIndex Unsigned32WithNA, + ifPerfL0RxPower Signed32WithNA, + ifPerfL0TxPower Signed32WithNA, + ifPerfL0InitialRxPower Signed32WithNA, + ifPerfL0ChromaticDispersion Signed32WithNA, + ifPerfL0DifferentialGroupDelay Unsigned32WithNA, + ifPerfL0InitialDifferentialGroupDelay Unsigned32WithNA, + ifPerfL0UpId Unsigned32, + ifPerfL0OpticalSNR Unsigned32WithNA, + ifPerfL0QFactor Unsigned32WithNA} + +ifPerfL0Index OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index assigned to each entry. + +" + ::= { ifPerfL0Entry 1 } + +ifPerfL0Name OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The management name of the performance object, + for example 'clientL0:1:2:1-2', where the first number indicates + subrack, the second slot number and the third/fourth + are the physical port numbers. + +" + ::= { ifPerfL0Entry 2 } + +ifPerfL0ConnIfPerfAdminIfIndex OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that describes to which index in ifPerfAdminIf table + this object is related. + +" + ::= { ifPerfL0Entry 3 } + +ifPerfL0RxPower OBJECT-TYPE + SYNTAX Signed32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Received power in units of 0.1 dBm. + +" + ::= { ifPerfL0Entry 4 } + +ifPerfL0TxPower OBJECT-TYPE + SYNTAX Signed32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Transmitted power in units of 0.1 dBm. + +" + ::= { ifPerfL0Entry 5 } + +ifPerfL0InitialRxPower OBJECT-TYPE + SYNTAX Signed32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Initial received power in units of 0.1 dBm. + The value is set using the install command. + +" + ::= { ifPerfL0Entry 6} + +ifPerfL0ChromaticDispersion OBJECT-TYPE + SYNTAX Signed32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Received chromatic dispersion that describe the spreading of a light + pulse as it travels down a fiber when light pulses launched close together. + +" + ::= { ifPerfL0Entry 7 } + +ifPerfL0DifferentialGroupDelay OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The arrival time difference between two polarization states at + the output of the media (fiber). + +" + ::= { ifPerfL0Entry 8 } + +ifPerfL0InitialDifferentialGroupDelay OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The initial received differential group delay in units of picoseconds. + The value is set using the install command. + +" + ::= { ifPerfL0Entry 9 } + +ifPerfL0UpId OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identity in the UP for the Perf Admin entry +" + DEFVAL { 0 } + ::= { ifPerfL0Entry 10 } + + +ifPerfL0OpticalSNR OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "OSNR of the received signal (dB/0.1nm) reported by the coherent module receiver. + +" + ::= { ifPerfL0Entry 11 } + +ifPerfL0QFactor OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Pre-FEC Q factor (dB). + +" + ::= { ifPerfL0Entry 12 } + +-- ---------------------------------------------------- +-- IfPerfL2Stat L2 group +-- ---------------------------------------------------- + +ifPerfL2StatTable OBJECT-TYPE + SYNTAX SEQUENCE OF IfPerfL2StatEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifPerfL2Stat performance group contains information and + configuration for all ifPerfL2Stat performance objects." + + ::= { ifPerfL2StatList 1 } + +ifPerfL2StatEntry OBJECT-TYPE + SYNTAX IfPerfL2StatEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the ifPerfL2Stat list. + +" + INDEX { ifPerfL2StatIndex } + ::= { ifPerfL2StatTable 1 } + +IfPerfL2StatEntry ::= + SEQUENCE { + ifPerfL2StatIndex Unsigned32, + ifPerfL2StatName MgmtNameString, + ifPerfL2StatConnIfPerfAdminIfIndex Unsigned32WithNA, + ifPerfL2StatPeriod PerfPeriodWithNA, + ifPerfL2StatType L2MeasurementTypeWithNA, + + -- Ethernet traffic data + ifPerfL2StatCurrentFrames Counter64, + ifPerfL2StatCurrentBytes Counter64, + ifPerfL2StatCurrentUnicastFrames Counter64, + ifPerfL2StatCurrentMulticastFrames Counter64, + ifPerfL2StatCurrentBroadcastFrames Counter64, + ifPerfL2StatMaxUtilization Unsigned32WithNA, + ifPerfL2StatAverageUtilization Unsigned32WithNA, + ifPerfL2StatCurrentUtilization Unsigned32WithNA } + +ifPerfL2StatIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index assigned to each entry. + +" + ::= { ifPerfL2StatEntry 1 } + +ifPerfL2StatName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The management name of the performance object, + for example 'clientL2:1:2:1-2', where the first number indicates + subrack, the second slot number and the third/fourth + are the physical port numbers. + +" + ::= { ifPerfL2StatEntry 2 } + +ifPerfL2StatConnIfPerfAdminIfIndex OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that describes to which index in ifPerfAdminIf table + this object is related. + +" + ::= { ifPerfL2StatEntry 3 } + +ifPerfL2StatPeriod OBJECT-TYPE + SYNTAX PerfPeriodWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Period, 15 minute or 24 hour. + - 15 minute interval measurements per + measurement point + + - 24 hour interval measurements per + measurement point + +" + ::= { ifPerfL2StatEntry 4 } + +ifPerfL2StatType OBJECT-TYPE + SYNTAX L2MeasurementTypeWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The direction type of signal the interface expects. + + rx - Only ingoing signal. + + tx - Only outgoing signal. + +" + ::= { ifPerfL2StatEntry 5 } + +ifPerfL2StatCurrentFrames OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of Ethernet frames during a particular interval. + +" + ::= { ifPerfL2StatEntry 6 } + +ifPerfL2StatCurrentBytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of bytes during a particular interval. + +" + ::= { ifPerfL2StatEntry 7 } + +ifPerfL2StatCurrentUnicastFrames OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of Ethernet unicast frames during a + particular interval. + +" + ::= { ifPerfL2StatEntry 8 } + +ifPerfL2StatCurrentMulticastFrames OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of Ethernet multicast frames during a + particular interval. + +" + ::= { ifPerfL2StatEntry 9 } + +ifPerfL2StatCurrentBroadcastFrames OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of Ethernet broadcast frames during a + particular interval. + +" + ::= { ifPerfL2StatEntry 10 } + +ifPerfL2StatMaxUtilization OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum bandwidth utilization of the received or + transmitted signal during a particular 15 minute or + 24 hour interval. + +" + ::= { ifPerfL2StatEntry 11 } + +ifPerfL2StatAverageUtilization OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average bandwidth utilization of the received or + transmitted signal during a particular 15 minute or + 24 hour interval. + +" + ::= { ifPerfL2StatEntry 12 } + +ifPerfL2StatCurrentUtilization OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Current bandwidth utilization of the received or + transmitted signal during a particular 15 minute or + 24 hour interval. + +" + ::= { ifPerfL2StatEntry 13 } + +-- ---------------------------------------------------- +-- IfPerfL2Error L2 group +-- ---------------------------------------------------- + +ifPerfL2ErrorTable OBJECT-TYPE + SYNTAX SEQUENCE OF IfPerfL2ErrorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifPerfL2Error performance group contains information and + configuration for all ifPerfL2Error performance objects." + + ::= { ifPerfL2ErrorList 1 } + +ifPerfL2ErrorEntry OBJECT-TYPE + SYNTAX IfPerfL2ErrorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the ifPerfL2Error list. + +" + INDEX { ifPerfL2ErrorIndex } + ::= { ifPerfL2ErrorTable 1 } + +IfPerfL2ErrorEntry ::= + SEQUENCE { + ifPerfL2ErrorIndex Unsigned32, + ifPerfL2ErrorName MgmtNameString, + ifPerfL2ErrorConnIfPerfAdminIfIndex Unsigned32WithNA, + ifPerfL2ErrorPeriod PerfPeriodWithNA, + ifPerfL2ErrorType L2MeasurementTypeWithNA, + + -- Ethernet traffic data + ifPerfL2ErrorCurrentUndersizedFrames Counter64, + ifPerfL2ErrorCurrentOversizedFrames Counter64, + ifPerfL2ErrorCurrentFragments Counter64, + ifPerfL2ErrorCurrentFcsErrors Counter64, + + -- Ethernet traffic thresholds + ifPerfL2ErrorUndersizedFramesThreshold Counter64, + ifPerfL2ErrorOversizedFramesThreshold Counter64, + ifPerfL2ErrorFragmentsThreshold Counter64, + ifPerfL2ErrorFcsErrorsThreshold Counter64, + + -- Ethernet traffic fault statuses + ifPerfL2ErrorUndersizedFramesFault FaultStatusWithNA, + ifPerfL2ErrorOversizedFramesFault FaultStatusWithNA, + ifPerfL2ErrorFragmentsFault FaultStatusWithNA, + ifPerfL2ErrorFcsErrorsFault FaultStatusWithNA } + +ifPerfL2ErrorIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index assigned to each entry. + +" + ::= { ifPerfL2ErrorEntry 1 } + +ifPerfL2ErrorName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The management name of the performance object, + for example 'clientL2:1:2:1-2', where the first number indicates + subrack, the second slot number and the third/fourth + are the physical port numbers. + +" + ::= { ifPerfL2ErrorEntry 2 } + +ifPerfL2ErrorConnIfPerfAdminIfIndex OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that describes to which index in ifPerfAdminIf table + this object is related. + +" + ::= { ifPerfL2ErrorEntry 3 } + +ifPerfL2ErrorPeriod OBJECT-TYPE + SYNTAX PerfPeriodWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Period, 15 minute or 24 hour. + - 15 minute interval measurements per + measurement point + + - 24 hour interval measurements per + measurement point + +" + ::= { ifPerfL2ErrorEntry 4 } + +ifPerfL2ErrorType OBJECT-TYPE + SYNTAX L2MeasurementTypeWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The direction type of signal the interface expects. + + rx - Only ingoing signal. + + tx - Only outgoing signal. + +" + ::= { ifPerfL2ErrorEntry 5 } + +ifPerfL2ErrorCurrentUndersizedFrames OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of undersized Ethernet frames during a + particular interval. + +" + ::= { ifPerfL2ErrorEntry 6 } + +ifPerfL2ErrorCurrentOversizedFrames OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of oversized Ethernet frames during a + particular interval. + Frames with a length over 9600 bytes are counted + as oversized frames. + +" + ::= { ifPerfL2ErrorEntry 7 } + +ifPerfL2ErrorCurrentFragments OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of fragmented Ethernet frames during a + particular interval. + +" + ::= { ifPerfL2ErrorEntry 8 } + +ifPerfL2ErrorCurrentFcsErrors OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of Ethernet frames with FCS or alignment + errors during a particular interval. + +" + ::= { ifPerfL2ErrorEntry 9 } + +ifPerfL2ErrorUndersizedFramesThreshold OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the threshold for the undersized frames alarm. + +" + DEFVAL { 10 } + ::= { ifPerfL2ErrorEntry 10 } + +ifPerfL2ErrorOversizedFramesThreshold OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the threshold for the oversized frames alarm. + A value 0 (zero) will disable the alarm. + +" + DEFVAL { 10 } + ::= { ifPerfL2ErrorEntry 11 } + +ifPerfL2ErrorFragmentsThreshold OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the threshold for the fragmented frames alarm. + +" + DEFVAL { 10 } + ::= { ifPerfL2ErrorEntry 12 } + +ifPerfL2ErrorFcsErrorsThreshold OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the threshold for the FCS errors alarm. + +" + DEFVAL { 10 } + ::= { ifPerfL2ErrorEntry 13 } + +ifPerfL2ErrorUndersizedFramesFault OBJECT-TYPE + SYNTAX FaultStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Undersized frames threshold exceeded. + + alarm: The number of undersized frames during a + period exceeds the associated threshold. + + ok: At the start of a new period the associated + undersized frames counter is reset to zero. + At the same time the fault status is cleared. + +" + + ::= { ifPerfL2ErrorEntry 14 } + +ifPerfL2ErrorOversizedFramesFault OBJECT-TYPE + SYNTAX FaultStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Oversized frames threshold exceeded. + + alarm: The number of oversized frames during a + period exceeds the associated threshold. + + ok: At the start of a new period the associated + oversized frames counter is reset to zero. + At the same time the fault status is cleared. + +" + ::= { ifPerfL2ErrorEntry 15 } + +ifPerfL2ErrorFragmentsFault OBJECT-TYPE + SYNTAX FaultStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fragments threshold exceeded. + + alarm: The number of fragmented frames during a + period exceeds the associated threshold. + + ok: At the start of a new period the associated + fragmented frames counter is reset to zero. + At the same time the fault status is cleared. + +" + ::= { ifPerfL2ErrorEntry 16 } + +ifPerfL2ErrorFcsErrorsFault OBJECT-TYPE + SYNTAX FaultStatusWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "FCS errors threshold exceeded. + + alarm: The number of FCS or alignment errors during a + period exceeds the associated threshold. + + ok: At the start of a new period the associated + FCS error counter is reset to zero. + At the same time the fault status is cleared. + +" + ::= { ifPerfL2ErrorEntry 17 } + +-- ---------------------------------------------------- +-- Delay measurement group +-- ---------------------------------------------------- + +ifPerfDelayTable OBJECT-TYPE + SYNTAX SEQUENCE OF IfPerfDelayEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The Delay group group contains information and + configuration for the delay measurment of line ports." + + ::= { ifPerfDelayList 1 } + +ifPerfDelayEntry OBJECT-TYPE + SYNTAX IfPerfDelayEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the ifPerf Delay list. + +" + INDEX { ifPerfDelayIndex } + ::= { ifPerfDelayTable 1 } + +IfPerfDelayEntry ::= + SEQUENCE { + ifPerfDelayIndex Unsigned32, + ifPerfDelayUId Unsigned32, + ifPerfDelayName MgmtNameString, + ifPerfDelayTwoWayFiberDelay Unsigned32WithNA, + ifPerfDelayConnIfPerfAdminIfIndex Unsigned32WithNA} + +ifPerfDelayIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index assigned to each entry. + +" + ::= { ifPerfDelayEntry 1 } + +ifPerfDelayUId OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An unique identifier assigned to each entry. + +" + ::= { ifPerfDelayEntry 2 } + +ifPerfDelayName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The management name of the object, + for example 'delay:1:2:1-2', where the first number indicates + subrack, the second slot number and the third/fourth + are the physical port numbers. + +" + ::= { ifPerfDelayEntry 3 } + +ifPerfDelayTwoWayFiberDelay OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured delay in ns. + +" + ::= { ifPerfDelayEntry 4 } + +ifPerfDelayConnIfPerfAdminIfIndex OBJECT-TYPE + SYNTAX Unsigned32WithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An index that describes to which index in ifPerfAdminIf table + this object is related. + +" + ::= { ifPerfDelayEntry 5 } + +-- ---------------------------------------------------- +-- Notifications +-- ---------------------------------------------------- + + +-- ---------------------------------------------------- +-- Object and event groups +-- ---------------------------------------------------- + +ifPerfGeneralGroupV1 OBJECT-GROUP + OBJECTS { + ifPerfGeneralConfigLastChangeTime, + ifPerfGeneralStateLastChangeTime, + ifPerfGeneralAdminTableSize, + ifPerfGeneralAdminConfigLastChangeTime, + ifPerfGeneralAdminStateLastChangeTime, + ifPerfGeneralFecTableSize, + ifPerfGeneralFecConfigLastChangeTime, + ifPerfGeneralFecStateLastChangeTime, + ifPerfGeneralG826TableSize, + ifPerfGeneralG826ConfigLastChangeTime, + ifPerfGeneralG826StateLastChangeTime, + ifPerfGeneralL1TableSize, + ifPerfGeneralL1ConfigLastChangeTime, + ifPerfGeneralL1StateLastChangeTime, + ifPerfGeneralL0TableSize, + ifPerfGeneralL0ConfigLastChangeTime, + ifPerfGeneralL0StateLastChangeTime } + STATUS deprecated + DESCRIPTION + "The general objects." + ::= { lumIfPerfGroups 1 } + +ifPerfAdminGroupV1 OBJECT-GROUP + OBJECTS { + ifPerfAdminIndex, + ifPerfAdminName, + ifPerfAdminConnIfBasicIfIndex, + ifPerfAdminAdminStatus, + ifPerfAdminReportMode, + ifPerfAdminOperStatus, + ifPerfAdminIsSuspect15m, + ifPerfAdminIsSuspect24h, + ifPerfAdminReset15m, + ifPerfAdminReset24h} + STATUS deprecated + DESCRIPTION + "The ifPerfAdmin objects." + ::= { lumIfPerfGroups 2 } + +ifPerfFecGroupV1 OBJECT-GROUP + OBJECTS { + ifPerfFecIndex, + ifPerfFecName, + ifPerfFecConnIfPerfAdminIfIndex, + ifPerfFecCorrectedZeros, + ifPerfFecCorrectedOnes, + ifPerfFecRxBerEstimation, + ifPerfFecRxAvgPreFecBer} + STATUS deprecated + DESCRIPTION + "The ifPerfFec objects." + ::= { lumIfPerfGroups 3 } + + +ifPerfG826GroupV1 OBJECT-GROUP + OBJECTS { + ifPerfG826Index, + ifPerfG826Name, + ifPerfG826ConnIfPerfAdminIfIndex, + ifPerfG826Period, + ifPerfG826Type, + ifPerfG826MonitorLevel, + ifPerfG826MonitorChannel, + ifPerfG826CounterEs, + ifPerfG826CounterSes, + ifPerfG826CounterUas, + ifPerfG826CounterBbe, + ifPerfG826ThresholdEs, + ifPerfG826ThresholdSes, + ifPerfG826ThresholdUas, + ifPerfG826ThresholdBbe, + ifPerfG826FaultStatusEs, + ifPerfG826FaultStatusSes, + ifPerfG826FaultStatusUas, + ifPerfG826FaultStatusBbe} + STATUS deprecated + DESCRIPTION + "The ifPerfG826 objects." + ::= { lumIfPerfGroups 4 } + +ifPerfL1GroupV1 OBJECT-GROUP + OBJECTS { + ifPerfL1Index, + ifPerfL1Name, + ifPerfL1ConnIfPerfAdminIfIndex, + ifPerfL1Period, + ifPerfL1Type, + ifPerfL1MaxUtilization, + ifPerfL1AverageUtilization } + STATUS deprecated + DESCRIPTION + "The ifPerfL1 objects." + ::= { lumIfPerfGroups 5 } + +ifPerfL0GroupV1 OBJECT-GROUP + OBJECTS { + ifPerfL0Index, + ifPerfL0Name, + ifPerfL0ConnIfPerfAdminIfIndex, + ifPerfL0RxPower, + ifPerfL0TxPower, + ifPerfL0InitialRxPower } + STATUS deprecated + DESCRIPTION + "The ifPerfL0 objects." + ::= { lumIfPerfGroups 6 } + +ifPerfGeneralGroupV2 OBJECT-GROUP + OBJECTS { + ifPerfGeneralConfigLastChangeTime, + ifPerfGeneralStateLastChangeTime, + ifPerfGeneralAdminTableSize, + ifPerfGeneralAdminConfigLastChangeTime, + ifPerfGeneralAdminStateLastChangeTime, + ifPerfGeneralFecTableSize, + ifPerfGeneralFecConfigLastChangeTime, + ifPerfGeneralFecStateLastChangeTime, + ifPerfGeneralG826TableSize, + ifPerfGeneralG826ConfigLastChangeTime, + ifPerfGeneralG826StateLastChangeTime, + ifPerfGeneralL1TableSize, + ifPerfGeneralL1ConfigLastChangeTime, + ifPerfGeneralL1StateLastChangeTime, + ifPerfGeneralL0TableSize, + ifPerfGeneralL0ConfigLastChangeTime, + ifPerfGeneralL0StateLastChangeTime, + ifPerfGeneralL2StatTableSize, + ifPerfGeneralL2StatConfigLastChangeTime, + ifPerfGeneralL2StatStateLastChangeTime, + ifPerfGeneralL2ErrorTableSize, + ifPerfGeneralL2ErrorConfigLastChangeTime, + ifPerfGeneralL2ErrorStateLastChangeTime } + STATUS deprecated + DESCRIPTION + "The general objects." + ::= { lumIfPerfGroups 7 } + +ifPerfL2StatGroupV1 OBJECT-GROUP + OBJECTS { + ifPerfL2StatIndex, + ifPerfL2StatName, + ifPerfL2StatConnIfPerfAdminIfIndex, + ifPerfL2StatPeriod, + ifPerfL2StatType, + ifPerfL2StatCurrentFrames, + ifPerfL2StatCurrentBytes, + ifPerfL2StatCurrentUnicastFrames, + ifPerfL2StatCurrentMulticastFrames, + ifPerfL2StatCurrentBroadcastFrames } + STATUS deprecated + DESCRIPTION + "The ifPerfL2Stat objects." + ::= { lumIfPerfGroups 8 } + +ifPerfL1GroupV2 OBJECT-GROUP + OBJECTS { + ifPerfL1Index, + ifPerfL1Name, + ifPerfL1ConnIfPerfAdminIfIndex, + ifPerfL1Period, + ifPerfL1Type, + ifPerfL1MaxUtilization, + ifPerfL1AverageUtilization, + ifPerfL1CurrentUtilization } + STATUS current + DESCRIPTION + "The ifPerfL2 objects." + ::= { lumIfPerfGroups 9 } + +ifPerfL0GroupV2 OBJECT-GROUP + OBJECTS { + ifPerfL0Index, + ifPerfL0Name, + ifPerfL0ConnIfPerfAdminIfIndex, + ifPerfL0RxPower, + ifPerfL0TxPower, + ifPerfL0InitialRxPower, + ifPerfL0ChromaticDispersion, + ifPerfL0DifferentialGroupDelay, + ifPerfL0InitialDifferentialGroupDelay} + STATUS deprecated + DESCRIPTION + "The ifPerfL0 objects." + ::= { lumIfPerfGroups 10 } + +ifPerfL2ErrorGroupV1 OBJECT-GROUP + OBJECTS { + ifPerfL2ErrorIndex, + ifPerfL2ErrorName, + ifPerfL2ErrorConnIfPerfAdminIfIndex, + ifPerfL2ErrorPeriod, + ifPerfL2ErrorType, + ifPerfL2ErrorCurrentUndersizedFrames, + ifPerfL2ErrorCurrentOversizedFrames, + ifPerfL2ErrorCurrentFragments, + ifPerfL2ErrorCurrentFcsErrors, + ifPerfL2ErrorUndersizedFramesThreshold, + ifPerfL2ErrorOversizedFramesThreshold, + ifPerfL2ErrorFragmentsThreshold, + ifPerfL2ErrorFcsErrorsThreshold, + ifPerfL2ErrorUndersizedFramesFault, + ifPerfL2ErrorOversizedFramesFault, + ifPerfL2ErrorFragmentsFault, + ifPerfL2ErrorFcsErrorsFault } + STATUS current + DESCRIPTION + "The ifPerfL2Error objects." + ::= { lumIfPerfGroups 11 } + +ifPerfFecGroupV2 OBJECT-GROUP + OBJECTS { + ifPerfFecIndex, + ifPerfFecName, + ifPerfFecConnIfPerfAdminIfIndex, + ifPerfFecCorrectedZeros, + ifPerfFecCorrectedOnes, + ifPerfFecRxBerEstimation, + ifPerfFecRxAvgPreFecBer, + ifPerfFecCorrectedBits} + STATUS deprecated + DESCRIPTION + "The ifPerfFec objects." + ::= { lumIfPerfGroups 12 } + +ifPerfFecGroupV3 OBJECT-GROUP + OBJECTS { + ifPerfFecIndex, + ifPerfFecName, + ifPerfFecConnIfPerfAdminIfIndex, + ifPerfFecCorrectedZeros, + ifPerfFecCorrectedOnes, + ifPerfFecRxBerEstimation, + ifPerfFecRxAvgPreFecBer, + ifPerfFecCorrectedBits, + ifPerfFecRxBitErrorEstimation} + STATUS deprecated + DESCRIPTION + "The ifPerfFec objects." + ::= { lumIfPerfGroups 13 } + +ifPerfAdminGroupV2 OBJECT-GROUP + OBJECTS { + ifPerfAdminIndex, + ifPerfAdminName, + ifPerfAdminConnIfBasicIfIndex, + ifPerfAdminAdminStatus, + ifPerfAdminReportMode, + ifPerfAdminOperStatus, + ifPerfAdminIsSuspect15m, + ifPerfAdminIsSuspect24h, + ifPerfAdminReset15m, + ifPerfAdminReset24h, + ifPerfAdminUpId} + STATUS current + DESCRIPTION + "The ifPerfAdmin objects. (R26)" + ::= { lumIfPerfGroups 14 } + +ifPerfG826GroupV2 OBJECT-GROUP + OBJECTS { + ifPerfG826Index, + ifPerfG826Name, + ifPerfG826ConnIfPerfAdminIfIndex, + ifPerfG826Period, + ifPerfG826Type, + ifPerfG826MonitorLevel, + ifPerfG826MonitorChannel, + ifPerfG826CounterEs, + ifPerfG826CounterSes, + ifPerfG826CounterUas, + ifPerfG826CounterBbe, + ifPerfG826ThresholdEs, + ifPerfG826ThresholdSes, + ifPerfG826ThresholdUas, + ifPerfG826ThresholdBbe, + ifPerfG826FaultStatusEs, + ifPerfG826FaultStatusSes, + ifPerfG826FaultStatusUas, + ifPerfG826FaultStatusBbe, + ifPerfG826UpId} + STATUS deprecated + DESCRIPTION + "The ifPerfG826 objects." + ::= { lumIfPerfGroups 15 } + +ifPerfL2StatGroupV2 OBJECT-GROUP + OBJECTS { + ifPerfL2StatIndex, + ifPerfL2StatName, + ifPerfL2StatConnIfPerfAdminIfIndex, + ifPerfL2StatPeriod, + ifPerfL2StatType, + ifPerfL2StatCurrentFrames, + ifPerfL2StatCurrentBytes, + ifPerfL2StatCurrentUnicastFrames, + ifPerfL2StatCurrentMulticastFrames, + ifPerfL2StatCurrentBroadcastFrames, + ifPerfL2StatMaxUtilization, + ifPerfL2StatAverageUtilization, + ifPerfL2StatCurrentUtilization } + STATUS current + DESCRIPTION + "The ifPerfL2Stat objects." + ::= { lumIfPerfGroups 16 } + +ifPerfFecGroupV4 OBJECT-GROUP + OBJECTS { + ifPerfFecIndex, + ifPerfFecName, + ifPerfFecConnIfPerfAdminIfIndex, + ifPerfFecCorrectedZeros, + ifPerfFecCorrectedOnes, + ifPerfFecRxBerEstimation, + ifPerfFecRxAvgPreFecBer, + ifPerfFecCorrectedBits, + ifPerfFecRxBitErrorEstimation, + ifPerfFecOpticalSNR } + STATUS deprecated + DESCRIPTION + "The ifPerfFec objects." + ::= { lumIfPerfGroups 17 } + +ifPerfL0GroupV3 OBJECT-GROUP + OBJECTS { + ifPerfL0Index, + ifPerfL0Name, + ifPerfL0ConnIfPerfAdminIfIndex, + ifPerfL0RxPower, + ifPerfL0TxPower, + ifPerfL0InitialRxPower, + ifPerfL0ChromaticDispersion, + ifPerfL0DifferentialGroupDelay, + ifPerfL0InitialDifferentialGroupDelay, + ifPerfL0UpId} + STATUS deprecated + DESCRIPTION + "The ifPerfL0 objects." + ::= { lumIfPerfGroups 18 } + +ifPerfFecGroupV5 OBJECT-GROUP + OBJECTS { + ifPerfFecIndex, + ifPerfFecName, + ifPerfFecConnIfPerfAdminIfIndex, + ifPerfFecCorrectedZeros, + ifPerfFecCorrectedOnes, + ifPerfFecRxBerEstimation, + ifPerfFecRxAvgPreFecBer, + ifPerfFecCorrectedBits, + ifPerfFecRxBitErrorEstimation, + ifPerfFecOpticalSNR, + ifPerfFecUpId} + STATUS deprecated + DESCRIPTION + "The ifPerfFec objects." + ::= { lumIfPerfGroups 19 } + +ifPerfGeneralGroupV3 OBJECT-GROUP + OBJECTS { + ifPerfGeneralConfigLastChangeTime, + ifPerfGeneralStateLastChangeTime, + ifPerfGeneralAdminTableSize, + ifPerfGeneralAdminConfigLastChangeTime, + ifPerfGeneralAdminStateLastChangeTime, + ifPerfGeneralFecTableSize, + ifPerfGeneralFecConfigLastChangeTime, + ifPerfGeneralFecStateLastChangeTime, + ifPerfGeneralG826TableSize, + ifPerfGeneralG826ConfigLastChangeTime, + ifPerfGeneralG826StateLastChangeTime, + ifPerfGeneralL1TableSize, + ifPerfGeneralL1ConfigLastChangeTime, + ifPerfGeneralL1StateLastChangeTime, + ifPerfGeneralL0TableSize, + ifPerfGeneralL0ConfigLastChangeTime, + ifPerfGeneralL0StateLastChangeTime, + ifPerfGeneralL2StatTableSize, + ifPerfGeneralL2StatConfigLastChangeTime, + ifPerfGeneralL2StatStateLastChangeTime, + ifPerfGeneralL2ErrorTableSize, + ifPerfGeneralL2ErrorConfigLastChangeTime, + ifPerfGeneralL2ErrorStateLastChangeTime, + ifPerfGeneralDelayTableSize, + ifPerfGeneralDelayConfigLastChangeTime, + ifPerfGeneralDelayStateLastChangeTime } + STATUS current + DESCRIPTION + "The general objects." + ::= { lumIfPerfGroups 20 } + +ifPerfDelayGroupV1 OBJECT-GROUP + OBJECTS { + ifPerfDelayIndex, + ifPerfDelayUId, + ifPerfDelayName, + ifPerfDelayTwoWayFiberDelay } + + STATUS deprecated + DESCRIPTION + "The Delay objects." + ::= { lumIfPerfGroups 21 } + +ifPerfDelayGroupV2 OBJECT-GROUP + OBJECTS { + ifPerfDelayIndex, + ifPerfDelayUId, + ifPerfDelayName, + ifPerfDelayTwoWayFiberDelay, + ifPerfDelayConnIfPerfAdminIfIndex } + + STATUS current + DESCRIPTION + "The Delay objects." + ::= { lumIfPerfGroups 22 } + +ifPerfFecGroupV6 OBJECT-GROUP + OBJECTS { + ifPerfFecIndex, + ifPerfFecName, + ifPerfFecConnIfPerfAdminIfIndex, + ifPerfFecCorrectedZeros, + ifPerfFecCorrectedOnes, + ifPerfFecRxBerEstimation, + ifPerfFecRxAvgPreFecBer, + ifPerfFecCorrectedBits, + ifPerfFecRxBitErrorEstimation, + ifPerfFecOpticalSNR, + ifPerfFecUpId, + ifPerfFecQMargin, + ifPerfFecPreFecBer} + STATUS current + DESCRIPTION + "The ifPerfFec objects." + ::= { lumIfPerfGroups 23 } + +ifPerfL0GroupV4 OBJECT-GROUP + OBJECTS { + ifPerfL0Index, + ifPerfL0Name, + ifPerfL0ConnIfPerfAdminIfIndex, + ifPerfL0RxPower, + ifPerfL0TxPower, + ifPerfL0InitialRxPower, + ifPerfL0ChromaticDispersion, + ifPerfL0DifferentialGroupDelay, + ifPerfL0InitialDifferentialGroupDelay, + ifPerfL0OpticalSNR, + ifPerfL0UpId, + ifPerfL0QFactor} + STATUS current + DESCRIPTION + "The ifPerfL0 objects." + ::= { lumIfPerfGroups 24 } + + ifPerfG826GroupV3 OBJECT-GROUP + OBJECTS { + ifPerfG826Index, + ifPerfG826Name, + ifPerfG826ConnIfPerfAdminIfIndex, + ifPerfG826Period, + ifPerfG826Type, + ifPerfG826MonitorLevel, + ifPerfG826MonitorChannel, + ifPerfG826CounterEs, + ifPerfG826CounterSes, + ifPerfG826CounterUas, + ifPerfG826CounterBbe, + ifPerfG826ThresholdEs, + ifPerfG826ThresholdSes, + ifPerfG826ThresholdUas, + ifPerfG826ThresholdBbe, + ifPerfG826FaultStatusEs, + ifPerfG826FaultStatusSes, + ifPerfG826FaultStatusUas, + ifPerfG826FaultStatusBbe, + ifPerfG826UpId, + ifPerfG826TribPortId} + STATUS current + DESCRIPTION + "The ifPerfG826 objects." + ::= { lumIfPerfGroups 25 } + +-- ---------------------------------------------------- +-- Compliance +-- ---------------------------------------------------- + +lumIfPerfComplV1 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB." + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV1, + ifPerfAdminGroupV1, + ifPerfFecGroupV1, + ifPerfG826GroupV1, + ifPerfL1GroupV1, + ifPerfL0GroupV1 } + ::= { lumIfPerfCompl 1 } + +lumIfPerfComplV2 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB." + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV1, + ifPerfFecGroupV1, + ifPerfG826GroupV1, + ifPerfL1GroupV1, + ifPerfL0GroupV1, + ifPerfL2StatGroupV1 } + ::= { lumIfPerfCompl 2 } + +lumIfPerfComplV3 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB." + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV1, + ifPerfFecGroupV1, + ifPerfG826GroupV1, + ifPerfL1GroupV2, + ifPerfL0GroupV1, + ifPerfL2StatGroupV1 } + ::= { lumIfPerfCompl 3 } + +lumIfPerfComplV4 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB." + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV1, + ifPerfFecGroupV1, + ifPerfG826GroupV1, + ifPerfL1GroupV2, + ifPerfL0GroupV2, + ifPerfL2StatGroupV1 } + ::= { lumIfPerfCompl 4 } + +lumIfPerfComplV5 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB." + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV1, + ifPerfFecGroupV1, + ifPerfG826GroupV1, + ifPerfL1GroupV2, + ifPerfL0GroupV2, + ifPerfL2StatGroupV1, + ifPerfL2ErrorGroupV1 } + ::= { lumIfPerfCompl 5 } + +lumIfPerfComplV6 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB." + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV1, + ifPerfFecGroupV2, + ifPerfG826GroupV1, + ifPerfL1GroupV2, + ifPerfL0GroupV2, + ifPerfL2StatGroupV1, + ifPerfL2ErrorGroupV1 } + ::= { lumIfPerfCompl 6 } + +lumIfPerfComplV7 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB." + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV1, + ifPerfFecGroupV3, + ifPerfG826GroupV1, + ifPerfL1GroupV2, + ifPerfL0GroupV2, + ifPerfL2StatGroupV1, + ifPerfL2ErrorGroupV1 } + ::= { lumIfPerfCompl 7 } + +lumIfPerfComplV8 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB. (R26)" + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV2, + ifPerfFecGroupV4, + ifPerfG826GroupV2, + ifPerfL1GroupV2, + ifPerfL0GroupV2, + ifPerfL2StatGroupV2, + ifPerfL2ErrorGroupV1 } + ::= { lumIfPerfCompl 8 } + +lumIfPerfComplV9 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB. (R26)" + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV2, + ifPerfFecGroupV4, + ifPerfG826GroupV2, + ifPerfL1GroupV2, + ifPerfL0GroupV3, + ifPerfL2StatGroupV2, + ifPerfL2ErrorGroupV1 } + ::= { lumIfPerfCompl 9 } + +lumIfPerfComplV10 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB. (R26)" + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV2, + ifPerfAdminGroupV2, + ifPerfFecGroupV5, + ifPerfG826GroupV2, + ifPerfL1GroupV2, + ifPerfL0GroupV3, + ifPerfL2StatGroupV2, + ifPerfL2ErrorGroupV1 } + ::= { lumIfPerfCompl 10 } + +lumIfPerfComplV11 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB. (R27.1)" + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV3, + ifPerfAdminGroupV2, + ifPerfFecGroupV5, + ifPerfG826GroupV2, + ifPerfL1GroupV2, + ifPerfL0GroupV3, + ifPerfL2StatGroupV2, + ifPerfL2ErrorGroupV1, + ifPerfDelayGroupV1 } + ::= { lumIfPerfCompl 11 } + +lumIfPerfComplV12 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB. (R29)" + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV3, + ifPerfAdminGroupV2, + ifPerfFecGroupV5, + ifPerfG826GroupV2, + ifPerfL1GroupV2, + ifPerfL0GroupV3, + ifPerfL2StatGroupV2, + ifPerfL2ErrorGroupV1, + ifPerfDelayGroupV2 } + ::= { lumIfPerfCompl 12 } + + +lumIfPerfComplV13 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Basic implementation requirements for the ifPerf MIB. (R32.1)" + MODULE + MANDATORY-GROUPS { + ifPerfGeneralGroupV3, + ifPerfAdminGroupV2, + ifPerfFecGroupV6, + ifPerfG826GroupV3, + ifPerfL1GroupV2, + ifPerfL0GroupV4, + ifPerfL2StatGroupV2, + ifPerfL2ErrorGroupV1, + ifPerfDelayGroupV2 } + ::= { lumIfPerfCompl 13 } + +END + |