summaryrefslogtreecommitdiff
path: root/MIBS/infinera/LUM-IFPERF-MIB
blob: 38955b49087f46e8c04a95a6717bc6a0d762c437 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
LUM-IFPERF-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter64
        FROM SNMPv2-SMI
    OBJECT-GROUP, MODULE-COMPLIANCE
        FROM SNMPv2-CONF
    TEXTUAL-CONVENTION, DateAndTime, DisplayString
        FROM SNMPv2-TC
    lumModules, lumIfPerfMIB
        FROM LUM-REG
    Unsigned32WithNA, MgmtNameString, AdminStatusWithNA, OperStatusWithNA,
    ResetWithNA, OnOff, FaultStatusWithNA, Signed32WithNA, CommandString, TribPortIdType
        FROM LUM-TC;

lumIfPerfMIBModule MODULE-IDENTITY
    LAST-UPDATED
        "201906280000Z" -- June 28th 2019
    ORGANIZATION
        "Infinera Corporation"
    CONTACT-INFO
        "techsupport@infinera.com"
    DESCRIPTION
        "The MIB module for management of performance objects.

        The tables contained in this MIB are:

        (1) The General group contains some general attributes as time stamps
            and tables sizes.

        (2) The ifPerfAdmin performance group contains information and
            configuration for all Admin performance objects

        (3) The ifPerfFec performance group contains information and
            configuration for all Fec performance objects.

        (4) The ifPerfG826 performance group contains information and
            configuration for all G826 performance objects. Notice table
            is uni-directional meaning one entry for each direction.

        (5) The ifPerfL1 performance group contains information and
            configuration for all L1 performance objects. Notice table
            is uni-directional meaning one entry for each direction.

        (6) The ifPerfL0 performance group contains information and
            configuration for all L0 performance objects.

        (7) The ifPerfL2 performance group contains information and
            configuration for all L2 performance objects.

"
    REVISION
        "201906280000Z" -- June 28th 2019
    DESCRIPTION
        "Changes made for release r33.0:
         - Added oa1x21dBmVgEC board
         - Added oa2x21dBmVgEC board"
    REVISION
         "201903300000Z" -- March 30th 2019
    DESCRIPTION
         "Changes made for release r32.1:
           - Added ifPerfL0OpticalSNR
           - Added ifPerfL0QFactor
           - Added ifPerfFecQMargin
           - Added ifPerfFecPreFecBer
           - Added ifPerfL0OpticalSNR and ifPerfFecQMargin
           - Added ifPerfG826TribPortId."
    REVISION
        "201706150000Z" -- June 15th 2017
    DESCRIPTION
        "Changes made for release r29.0:
         - Changed ORGANIZATION and CONTACT-INFO"
    REVISION
        "201611300000Z" -- November 30th 2016
    DESCRIPTION
        "Changes made for release r28:
        - Added tp100gotnii board."
    REVISION
        "201609300000Z" -- September 30th 2016
    DESCRIPTION
        "Changes made for release r27.1:
        - Added rfuac1 board."
    REVISION
        "201601110000Z" -- Jan 11th 2016
    DESCRIPTION
        "Added default operStatus to notPresent."
    REVISION
        "201512220000Z" -- December 22nd 2015
    DESCRIPTION
        "Changes made for release r27:
        - Added fhau1 board
        - Added fha1u1 board"
    REVISION
        "201511300000Z" -- Nov 30th 2015
    DESCRIPTION
        "Changes made for release r26:
        - Added attribute optical SNR."
    REVISION
        "201505290000Z" -- May 29th 2015
    DESCRIPTION
        "Changes made for release r25:
        - Added attribute FEC corrected bits.
        - Added corresponding FEC RxBitErorrEstimate attribute as display string."
    REVISION
        "201409300000Z" -- September 30th 2014
    DESCRIPTION
        "Changes made for release r23.1:
        - Added mxp100gotn board."
    REVISION
        "201405160000Z" -- May 16th 2014
    DESCRIPTION
        "Changes made for release r23:
        - Added some L2 PM attributes
        - Added some L0 PM attributes"
    REVISION
        "201311150000Z" -- November 15th 2013
    DESCRIPTION
        "Changes made for release r22:
        - Added tp10gotn, tp100gotn board.
        - Added the L2 table
        - Added Current Utilization attribute"
    REVISION
        "201305010000Z" -- May 1st 2013
    DESCRIPTION
        "The initial revision of this module."
    ::= { lumModules 56 }


PerfPeriodWithNA ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "The period time for performance data.

        period15minutes - 15 minutes
        period24hours - 24 hours"

    SYNTAX INTEGER {
        period15minutes (1),
        period24hours (2),
        notApplicable (2147483647) }


G826MonitorLevelWithNA ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "The monitor level."

    SYNTAX INTEGER {
        opu0 (1),
        odu0 (2),
        otu0 (3),
        opu1 (4),
        odu1 (5),
        otu1 (6),
        opu2 (7),
        odu2 (8),
        otu2 (9),
        opu3 (10),
        odu3 (11),
        otu3 (12),
        opu4 (13),
        odu4 (14),
        otu4 (15),
        oduFlex (16),
        rs (17),
        ms (18),
        mac (19),
        pcs (20),
        cpriL1 (21),
        obsaiL1 (22),
        irsoh (23),
        imsoh (24),
        otuj2 (25),
        opuFlex (26),
        otuj1 (27),
        notApplicable (2147483647) }


G826MonitorChannelWithNA ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "The monitor channel."

    SYNTAX INTEGER {
        unused (0),
        sm (1),
        pm (2),
        tcm1 (3),
        tcm2 (4),
        tcm3 (5),
        tcm4 (6),
        tcm5 (7),
        tcm6 (8),
        notAvailable (2147483646),
        notApplicable (2147483647) }


L1MeasurementTypeWithNA ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "The direction type.

        rx - receiver, only ingoing signal
        tx - transmitter, only outgoing signal"

    SYNTAX INTEGER {
        rx (1),
        tx (2),
        notApplicable (2147483647) }

L2MeasurementTypeWithNA ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "The direction type.

        rx - receiver, only ingoing signal
        tx - transmitter, only outgoing signal"

    SYNTAX INTEGER {
        rx (1),
        tx (2),
        notApplicable (2147483647) }


G826MeasurementTypeWithNA ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "The direction type.

        rx - receiver, only ingoing signal
        tx - transmitter, only outgoing signal
        uniDi - unidirectional
        biDi - bidirectional, ingoing and outgoing signal on the same port"

    SYNTAX INTEGER {
        rx (1),
        tx (2),
        uniDi (3),
        biDi (4),
        notApplicable (2147483647) }

BooleanValueWithNA ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "Defines a value that can be true, false or not available

        true -        The condition is true

        false -       The condition is false

        notAvailable (2147483646) is used when attribute is
        not available under current circumstances. This value
        is only used when used for a state.

        notApplicable (2147483647) is used when attribute is
        not used in current configuration."

    SYNTAX INTEGER {
           true (1),
           false (2),
           notAvailable (2147483646),
           notApplicable (2147483647) }


-- ----------------------------------------------------
-- Compliance area, containing groups and compliance
-- specifications.
-- ----------------------------------------------------

lumIfPerfConfs OBJECT IDENTIFIER ::= { lumIfPerfMIB 1 }
lumIfPerfGroups OBJECT IDENTIFIER ::= { lumIfPerfConfs 1 }
lumIfPerfCompl OBJECT IDENTIFIER ::= { lumIfPerfConfs 2 }


-- ----------------------------------------------------
-- Root for objects in the IFPERF MIB
-- ----------------------------------------------------

lumIfPerfMIBObjects OBJECT IDENTIFIER ::= { lumIfPerfMIB 2 }


-- ----------------------------------------------------
-- This MIB contains the following groups:
-- ----------------------------------------------------

ifPerfGeneral OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 1 }
ifPerfAdminList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 2 }
ifPerfFecList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 3 }
ifPerfG826List OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 4 }
ifPerfL1List OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 5 }
ifPerfL0List OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 6 }
ifPerfL2StatList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 7 }
ifPerfL2ErrorList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 8 }
ifPerfDelayList OBJECT IDENTIFIER ::= { lumIfPerfMIBObjects 9 }

-- ----------------------------------------------------
-- General group
-- ----------------------------------------------------


ifPerfGeneralConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the MIB was
        last changed.

"
    ::= { ifPerfGeneral 1 }

ifPerfGeneralStateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the MIB was last changed.

"
    ::= { ifPerfGeneral 2 }

ifPerfGeneralAdminTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Size of ifPerfAdmin performance table.

"
    ::= { ifPerfGeneral 3 }

ifPerfGeneralAdminConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the table was
        last changed.

"
    ::= { ifPerfGeneral 4 }

ifPerfGeneralAdminStateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the table was last changed.

"
    ::= { ifPerfGeneral 5 }

ifPerfGeneralFecTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Size of ifPerfFec performance table.

"
    ::= { ifPerfGeneral 6 }

ifPerfGeneralFecConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the table was
        last changed.

"
    ::= { ifPerfGeneral 7 }

ifPerfGeneralFecStateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the table was last changed.

"
    ::= { ifPerfGeneral 8 }

ifPerfGeneralG826TableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Size of ifPerfG826 performance table.

"
    ::= { ifPerfGeneral 9 }

ifPerfGeneralG826ConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the table was
        last changed.

"
    ::= { ifPerfGeneral 10 }

ifPerfGeneralG826StateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the table was last changed.

"
    ::= { ifPerfGeneral 11 }

ifPerfGeneralL1TableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Size of ifPerfL1 performance table.

"
    ::= { ifPerfGeneral 12 }

ifPerfGeneralL1ConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the table was
        last changed.

"
    ::= { ifPerfGeneral 13 }

ifPerfGeneralL1StateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the table was last changed.

"
    ::= { ifPerfGeneral 14 }

ifPerfGeneralL0TableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Size of ifPerfL0 performance table.

"
    ::= { ifPerfGeneral 15 }

ifPerfGeneralL0ConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the table was
        last changed.

"
    ::= { ifPerfGeneral 16 }

ifPerfGeneralL0StateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the table was last changed.

"
    ::= { ifPerfGeneral 17 }

ifPerfGeneralL2StatTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Size of ifPerfL0 performance table.

"
    ::= { ifPerfGeneral 18 }

ifPerfGeneralL2StatConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the table was
        last changed.

"
    ::= { ifPerfGeneral 19 }

ifPerfGeneralL2StatStateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the table was last changed.

"
    ::= { ifPerfGeneral 20 }

ifPerfGeneralL2ErrorTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Size of ifPerfL0 performance table.

"
    ::= { ifPerfGeneral 21 }

ifPerfGeneralL2ErrorConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the table was
        last changed.

"
    ::= { ifPerfGeneral 22 }

ifPerfGeneralL2ErrorStateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the table was last changed.

"
    ::= { ifPerfGeneral 23 }

ifPerfGeneralDelayTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Size of ifPerfDelay performance table.

"
    ::= { ifPerfGeneral 24 }

ifPerfGeneralDelayConfigLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the configuration of the table was
        last changed.

"
    ::= { ifPerfGeneral 25 }

ifPerfGeneralDelayStateLastChangeTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the state and/or configuration of
        the table was last changed.

"
    ::= { ifPerfGeneral 26 }

-- ----------------------------------------------------
-- IfPerfAdmin admin group
-- ----------------------------------------------------

ifPerfAdminTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfPerfAdminEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The  ifPerfAdmin performance group contains information and
        configuration for all ifPerfAdmin performance objects."

    ::= { ifPerfAdminList 1 }

ifPerfAdminEntry OBJECT-TYPE
    SYNTAX      IfPerfAdminEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the ifPerfAdmin list.

"
    INDEX { ifPerfAdminIndex }
    ::= { ifPerfAdminTable 1 }

IfPerfAdminEntry ::=
    SEQUENCE {
        ifPerfAdminIndex                        Unsigned32,
        ifPerfAdminName                         MgmtNameString,
        ifPerfAdminConnIfBasicIfIndex           Unsigned32WithNA,
        ifPerfAdminAdminStatus                  AdminStatusWithNA,
        ifPerfAdminReportMode                   OnOff,
        ifPerfAdminOperStatus                   OperStatusWithNA,
        ifPerfAdminIsSuspect15m                 BooleanValueWithNA,
        ifPerfAdminIsSuspect24h                 BooleanValueWithNA,
        ifPerfAdminReset15m                     ResetWithNA,
        ifPerfAdminReset24h                     ResetWithNA,
        ifPerfAdminUpId                         Unsigned32  }

ifPerfAdminIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index assigned to each entry.

"
    ::= { ifPerfAdminEntry 1 }


ifPerfAdminName OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The management name of the performance object,
        for example 'lineAdmin:1:2:1-2', where the first number indicates
        subrack, the second slot number and the third/fourth
        are the physical port numbers.

"
    ::= { ifPerfAdminEntry 2 }

ifPerfAdminConnIfBasicIfIndex OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "An index that describes to which index in ifBasicIf table
        this object is related.

"
    ::= { ifPerfAdminEntry 3 }

ifPerfAdminAdminStatus OBJECT-TYPE
    SYNTAX      AdminStatusWithNA
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The administrative state of the ifPerf interface.

        down - The interface is de-activated.

        service - The interface is activated.

        up - The interface will be activated when
        available.

"
    DEFVAL { up }
    ::= { ifPerfAdminEntry 4 }

ifPerfAdminReportMode OBJECT-TYPE
    SYNTAX      OnOff
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The performance reporting mode on the interface.

        off - performance reporting is inactive.

        on - performance reporting is activated.

"
    DEFVAL { on }
    ::= { ifPerfAdminEntry 5 }

ifPerfAdminOperStatus OBJECT-TYPE
    SYNTAX      OperStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The operational state for the interface.

        notPresent - The interface is not available.

        down - The interface is de-activated or there are
        faults preventing its transition to the 'up' state.

        up - The interface is active.

"
    DEFVAL { notPresent }
    ::= { ifPerfAdminEntry 6 }

ifPerfAdminIsSuspect15m OBJECT-TYPE
    SYNTAX      BooleanValueWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates if the performance data is
        unreliable for the 15 minute interval. The 'isSuspect'
        value is set to true if the interface has
        been reconfigured or reset during the maintenance
        operation. For example if
        - a full interval has not passed since last reset
        - the board has been restarted during the interval
        - adminStatus has been set to down
        - the system time has been set in the node during the interval.

"
    ::= { ifPerfAdminEntry 7 }

ifPerfAdminIsSuspect24h OBJECT-TYPE
    SYNTAX      BooleanValueWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This variable indicates if the performance data is
        unreliable for the 24 hour interval. The 'isSuspect'
        value is set to true if the interface has
        been reconfigured or reset during the maintenance
        operation. For example if
        - a full interval has not passed since last reset
        - the board has been restarted during the interval
        - adminStatus has been set to down
        - the system time has been set in the node during the interval.

"
    ::= { ifPerfAdminEntry 8 }

ifPerfAdminReset15m OBJECT-TYPE
    SYNTAX      ResetWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reset all performance counters for the 15 minute interval.
        After a successful reset the default value
        (normal) is restored in this attribute.

"
    DEFVAL { normal }
    ::= { ifPerfAdminEntry 9 }

ifPerfAdminReset24h OBJECT-TYPE
    SYNTAX      ResetWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reset performance counters for the 24 hour interval.
        After a successful reset the default value
        (normal) is restored in this attribute.

        notApplicable (2147483647) is used when attribute is
        not used in current configuration.

"
    DEFVAL { normal }
    ::= { ifPerfAdminEntry 10 }

ifPerfAdminUpId OBJECT-TYPE
    SYNTAX      Unsigned32   (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
    "Identity in the UP for the Perf Admin entry
"
    DEFVAL { 0  }
    ::= { ifPerfAdminEntry 11 }

-- ----------------------------------------------------
-- IfPerfFec fec group
-- ----------------------------------------------------

ifPerfFecTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfPerfFecEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The  ifPerfFec performance group contains information and
         configuration for all ifPerfFec performance objects."

    ::= { ifPerfFecList 1 }

ifPerfFecEntry OBJECT-TYPE
    SYNTAX      IfPerfFecEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the ifPerfFec list.

"
    INDEX { ifPerfFecIndex }
    ::= { ifPerfFecTable 1 }

IfPerfFecEntry ::=
    SEQUENCE {
        ifPerfFecIndex                        Unsigned32,
        ifPerfFecName                         MgmtNameString,
        ifPerfFecConnIfPerfAdminIfIndex       Unsigned32WithNA,
        ifPerfFecCorrectedZeros               Unsigned32WithNA,
        ifPerfFecCorrectedOnes                Unsigned32WithNA,
        ifPerfFecRxBerEstimation              Unsigned32WithNA,
        ifPerfFecRxAvgPreFecBer               Unsigned32WithNA,
        ifPerfFecCorrectedBits                Unsigned32WithNA,
        ifPerfFecRxBitErrorEstimation         DisplayString,
        ifPerfFecOpticalSNR                   Unsigned32WithNA,
        ifPerfFecUpId                         Unsigned32,
        ifPerfFecQMargin                      Unsigned32WithNA,
        ifPerfFecPreFecBer                    DisplayString }

ifPerfFecIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index assigned to each entry.

"
    ::= { ifPerfFecEntry 1 }

ifPerfFecName OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The management name of the performance object,
        for example 'lineFec:1:2:1-2', where the first number indicates
        subrack, the second slot number and the third/fourth
        are the physical port numbers.

"
    ::= { ifPerfFecEntry 2 }

ifPerfFecConnIfPerfAdminIfIndex OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "An index that describes to which index in ifPerfAdminIf table
        this object is related.

"
    ::= { ifPerfFecEntry 3 }

ifPerfFecCorrectedZeros OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "FEC counter. Number of corrected zeros.

"
    ::= { ifPerfFecEntry 4 }

ifPerfFecCorrectedOnes OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "FEC counter. Number of corrected ones.

"
    ::= { ifPerfFecEntry 5 }

ifPerfFecRxBerEstimation OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Rx Bit Error Rate estimation.

"
    ::= { ifPerfFecEntry 6 }

ifPerfFecRxAvgPreFecBer OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Rx Average Pre FEC Bit Error Rate of PM interval.

"
    ::= { ifPerfFecEntry 7 }

ifPerfFecCorrectedBits OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "FEC counter. Number of corrected bits.

"
    ::= { ifPerfFecEntry 8 }

ifPerfFecRxBitErrorEstimation OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Rx Bit Error Rate estimation.

"
    DEFVAL { " " }
    ::= { ifPerfFecEntry 9 }

ifPerfFecOpticalSNR OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Optical signal-to-noise ratio margin (dB/0.1nm) with respect to FEC cliff, based on calculation from rate of corrected bits.

"
    ::= { ifPerfFecEntry 10 }

ifPerfFecUpId OBJECT-TYPE
    SYNTAX      Unsigned32   (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Identity in the UP for the Perf Admin entry

"
    DEFVAL { 0  }
    ::= { ifPerfFecEntry 11 }

ifPerfFecQMargin OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Q factor margin (dB) with respect to the FEC threshold.

"
    ::= { ifPerfFecEntry 12 }

ifPerfFecPreFecBer OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Pre-FEC BER.

"
    DEFVAL { "" }
    ::= { ifPerfFecEntry 13 }

-- ----------------------------------------------------
-- IfPerfG826 g826 group
-- ----------------------------------------------------

ifPerfG826Table OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfPerfG826Entry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ifPerfG826 performance group contains information and
         configuration for all ifPerfG826 performance objects. Notice table
         is uni-directional meaning one entry for each direction."

    ::= { ifPerfG826List 1 }

ifPerfG826Entry OBJECT-TYPE
    SYNTAX      IfPerfG826Entry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the ifPerfG826 list.


"
    INDEX { ifPerfG826Index }
    ::= { ifPerfG826Table 1 }

IfPerfG826Entry ::=
    SEQUENCE {
        ifPerfG826Index                  Unsigned32,
        ifPerfG826Name                   MgmtNameString,
        ifPerfG826ConnIfPerfAdminIfIndex Unsigned32WithNA,
        ifPerfG826Period                 PerfPeriodWithNA,
        ifPerfG826Type                   G826MeasurementTypeWithNA,
        ifPerfG826MonitorLevel           G826MonitorLevelWithNA,
        ifPerfG826MonitorChannel         G826MonitorChannelWithNA,
        ifPerfG826CounterEs              Unsigned32WithNA,
        ifPerfG826CounterSes             Unsigned32WithNA,
        ifPerfG826CounterUas             Unsigned32WithNA,
        ifPerfG826CounterBbe             Counter64,
        ifPerfG826ThresholdEs            Unsigned32WithNA,
        ifPerfG826ThresholdSes           Unsigned32WithNA,
        ifPerfG826ThresholdUas           Unsigned32WithNA,
        ifPerfG826ThresholdBbe           Counter64,
        ifPerfG826FaultStatusEs          FaultStatusWithNA,
        ifPerfG826FaultStatusSes         FaultStatusWithNA,
        ifPerfG826FaultStatusUas         FaultStatusWithNA,
        ifPerfG826FaultStatusBbe         FaultStatusWithNA,
        ifPerfG826UpId                   Unsigned32,
        ifPerfG826TribPortId             TribPortIdType }

ifPerfG826Index OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index assigned to each entry.

"
    ::= { ifPerfG826Entry 1 }

ifPerfG826Name OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The management name of the performance object,
        for example 'lineG826OtsOtu2SmUni15m:1:2:23-24',
        where the textual part indicates the hierarchy and type
        line/client
        G826
        OTS/OTUk/ODUk/OPUk/RS/MS/MAC/PCS etc or any combination thereof
        SM/PM/TCMn monitor channel type, no monitor type is also possible
        Rx/Tx/Uni/Bi direction type
        15m/24h time period, 15 minutes or 24 hours

        For the part after the colon the first number indicates
        subrack, the second slot number and the third/fourth
        are the physical port numbers.

"
    ::= { ifPerfG826Entry 2 }

ifPerfG826ConnIfPerfAdminIfIndex OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "An index that describes to which index in ifPerfAdminIf table
        this object is related.

"
    ::= { ifPerfG826Entry 3 }

ifPerfG826Period OBJECT-TYPE
    SYNTAX      PerfPeriodWithNA
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Period, 15 minute or 24 hour.
        - 15 minute interval measurements per
        measurement point

        - 24 hour interval measurements per
        measurement point

"
    ::= { ifPerfG826Entry 4 }

ifPerfG826Type OBJECT-TYPE
    SYNTAX      G826MeasurementTypeWithNA
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The direction type of signal the interface expects.

        rx - Only ingoing signal.

        tx - Only outgoing signal.

        uniDi - Unidirectional signal.

        biDi - Ingoing and outgoing signal on the same
        port.

"
    ::= { ifPerfG826Entry 5 }

ifPerfG826MonitorLevel OBJECT-TYPE
    SYNTAX      G826MonitorLevelWithNA
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Monitor level, e.g. OPUk, ODUk, OTUk, RS, MS, MAC, PCS.

"
    ::= { ifPerfG826Entry 6 }

ifPerfG826MonitorChannel OBJECT-TYPE
    SYNTAX      G826MonitorChannelWithNA
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Monitor channel, e.g. SM, PM, TCM1-6.

"
    ::= { ifPerfG826Entry 7 }

ifPerfG826CounterEs OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Errored Seconds.
        The counter associated with the number of
        errored seconds in the interval specified by the
        period attribute.

"
    ::= { ifPerfG826Entry 8 }

ifPerfG826CounterSes OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Severely Errored Seconds.
        The counter associated with the number of
        severely errored seconds in the interval specified
        by the period attribute.

"
    ::= { ifPerfG826Entry 9 }

ifPerfG826CounterUas OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Unavailable Seconds.
        The counter associated with the number of
        unavailable seconds in the interval specified
        by the period attribute.

"
    ::= { ifPerfG826Entry 10 }

ifPerfG826CounterBbe OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Background Block Errors.
        The counter associated with the number of
        background block errors in the interval specified
        by the period attribute.

"
    ::= { ifPerfG826Entry 11 }

ifPerfG826ThresholdEs OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Sets the threshold in seconds for the
        errored seconds alarm.

        Range     15m: 0 to 900 seconds
                  24h: 0 to 86400 seconds

"
    DEFVAL { 20 }
    ::= { ifPerfG826Entry 12 }

ifPerfG826ThresholdSes OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Sets the threshold in seconds for the
        severely errored seconds alarm.

        Range     15m: 0 to 900 seconds
                  24h: 0 to 86400 seconds

"
    DEFVAL { 10 }
    ::= { ifPerfG826Entry 13 }

ifPerfG826ThresholdUas OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Sets the threshold in seconds for the
        unavailable seconds alarm.

        Range     15m: 0 to 900 seconds
                  24h: 0 to 86400 seconds

"
    DEFVAL { 30 }
    ::= { ifPerfG826Entry 14 }

ifPerfG826ThresholdBbe OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Sets the threshold for the
        background block errors alarms.

"
    DEFVAL { 100000 }
    ::= { ifPerfG826Entry 15 }

ifPerfG826FaultStatusEs OBJECT-TYPE
    SYNTAX      FaultStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Errored Seconds threshold exceeded.

        alarm: The number of errors during a period
        exceeds the associated threshold.

        ok: The number of errored seconds during a
        period is below the threshold.

"
    ::= { ifPerfG826Entry 16 }

ifPerfG826FaultStatusSes OBJECT-TYPE
    SYNTAX      FaultStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Severely Errored Seconds threshold exceeded.

        alarm: The number of severely errored seconds
        during a period exceeds the associated threshold.

        ok: The number of severely errored seconds during
        a period is below the threshold.

"
    ::= { ifPerfG826Entry 17 }

ifPerfG826FaultStatusUas OBJECT-TYPE
    SYNTAX      FaultStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Unavailable Seconds threshold exceeded.

        alarm: The number of unavailable seconds during
        a period exceeds the associated threshold.

        ok: The number of unavailable seconds during a
        period is below the threshold.

"
    ::= { ifPerfG826Entry 18 }

ifPerfG826FaultStatusBbe OBJECT-TYPE
    SYNTAX      FaultStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Background Block Errors threshold exceeded.

        alarm: The number of background block errors
        during a period exceeds the associated threshold.

        ok: The number of background block errors during
        a period is below the threshold.

"
    ::= { ifPerfG826Entry 19 }

ifPerfG826UpId OBJECT-TYPE
    SYNTAX      Unsigned32   (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Identity in the UP for the Perf Admin entry

"
    DEFVAL { 0  }
    ::= { ifPerfG826Entry 20 }

ifPerfG826TribPortId OBJECT-TYPE
    SYNTAX      TribPortIdType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Tributary port id that describes to which high-order
         tributary port this object belong to.

"
    DEFVAL { 0 }
    ::= { ifPerfG826Entry 21 }

-- ----------------------------------------------------
-- IfPerfL1 l1 group
-- ----------------------------------------------------

ifPerfL1Table OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfPerfL1Entry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The  ifPerfL1 performance group contains information and
         configuration for all ifPerfL1 performance objects. Notice table
         is uni-directional meaning one entry for each direction."

    ::= { ifPerfL1List 1 }

ifPerfL1Entry OBJECT-TYPE
    SYNTAX      IfPerfL1Entry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the ifPerfL1 list.

"
    INDEX { ifPerfL1Index }
    ::= { ifPerfL1Table 1 }

IfPerfL1Entry ::=
    SEQUENCE {
        ifPerfL1Index                  Unsigned32,
        ifPerfL1Name                   MgmtNameString,
        ifPerfL1ConnIfPerfAdminIfIndex Unsigned32WithNA,
        ifPerfL1Period                 PerfPeriodWithNA,
        ifPerfL1Type                   L1MeasurementTypeWithNA,
        ifPerfL1MaxUtilization         Unsigned32WithNA,
        ifPerfL1AverageUtilization     Unsigned32WithNA,
        ifPerfL1CurrentUtilization     Unsigned32WithNA }

ifPerfL1Index OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index assigned to each entry.

"
    ::= { ifPerfL1Entry 1 }

ifPerfL1Name OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The management name of the performance object,
        for example 'clientL1Rx15m:1:2:1-2',
        where the textual part indicates the type
        line/client
        L1
        Rx/Tx/Uni/Bi direction type
        15m/24h time period, 15 minutes or 24 hours

        For the part after the colon the first number indicates
        subrack, the second slot number and the third/fourth
        are the physical port numbers.

"
    ::= { ifPerfL1Entry 2 }

ifPerfL1ConnIfPerfAdminIfIndex OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index that describes to which index in ifPerfAdminIf table
        this object is related.

"
    ::= { ifPerfL1Entry 3 }

ifPerfL1Period OBJECT-TYPE
    SYNTAX      PerfPeriodWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Period, 15 minute or 24 hour.
        - 15 minute interval measurements per
        measurement point

        - 24 hour interval measurements per
        measurement point

"
    ::= { ifPerfL1Entry 4 }

ifPerfL1Type OBJECT-TYPE
    SYNTAX      L1MeasurementTypeWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The direction type of signal the interface expects.

        rx - Only ingoing signal.

        tx - Only outgoing signal.

"
    ::= { ifPerfL1Entry 5 }

ifPerfL1MaxUtilization OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The maximum bandwidth utilization of the received or
         transmitted signal during a particular 15 minute or
         24 hour interval.

"
    ::= { ifPerfL1Entry 6 }

ifPerfL1AverageUtilization OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The average bandwidth utilization of the received or
         transmitted signal during a particular 15 minute or
         24 hour interval.

"
    ::= { ifPerfL1Entry 7 }

ifPerfL1CurrentUtilization OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Current bandwidth utilization of the received or
         transmitted signal during a particular 15 minute or
         24 hour interval.

"
    ::= { ifPerfL1Entry 8 }

-- ----------------------------------------------------
-- IfPerfL0 l0 group
-- ----------------------------------------------------

ifPerfL0Table OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfPerfL0Entry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The  ifPerfL0 performance group contains information and
         configuration for all ifPerfL0 performance objects."

    ::= { ifPerfL0List 1 }

ifPerfL0Entry OBJECT-TYPE
    SYNTAX      IfPerfL0Entry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the ifPerfL0 list.

"
    INDEX { ifPerfL0Index }
    ::= { ifPerfL0Table 1 }

IfPerfL0Entry ::=
    SEQUENCE {
        ifPerfL0Index                           Unsigned32,
        ifPerfL0Name                            MgmtNameString,
        ifPerfL0ConnIfPerfAdminIfIndex          Unsigned32WithNA,
        ifPerfL0RxPower                         Signed32WithNA,
        ifPerfL0TxPower                         Signed32WithNA,
        ifPerfL0InitialRxPower                  Signed32WithNA,
        ifPerfL0ChromaticDispersion             Signed32WithNA,
        ifPerfL0DifferentialGroupDelay          Unsigned32WithNA,
        ifPerfL0InitialDifferentialGroupDelay   Unsigned32WithNA,
        ifPerfL0UpId                            Unsigned32,
        ifPerfL0OpticalSNR                      Unsigned32WithNA,
        ifPerfL0QFactor                         Unsigned32WithNA}

ifPerfL0Index OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index assigned to each entry.

"
    ::= { ifPerfL0Entry 1 }

ifPerfL0Name OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The management name of the performance object,
        for example 'clientL0:1:2:1-2', where the first number indicates
        subrack, the second slot number and the third/fourth
        are the physical port numbers.

"
    ::= { ifPerfL0Entry 2 }

ifPerfL0ConnIfPerfAdminIfIndex OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index that describes to which index in ifPerfAdminIf table
        this object is related.

"
    ::= { ifPerfL0Entry 3 }

ifPerfL0RxPower OBJECT-TYPE
    SYNTAX      Signed32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received power in units of 0.1 dBm.

"
    ::= { ifPerfL0Entry 4 }

ifPerfL0TxPower OBJECT-TYPE
    SYNTAX      Signed32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Transmitted power in units of 0.1 dBm.

"
    ::= { ifPerfL0Entry 5 }

ifPerfL0InitialRxPower OBJECT-TYPE
    SYNTAX      Signed32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Initial received power in units of 0.1 dBm.
         The value is set using the install command.

"
    ::= { ifPerfL0Entry 6}

ifPerfL0ChromaticDispersion OBJECT-TYPE
    SYNTAX      Signed32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Received chromatic dispersion that describe the spreading of a light
         pulse as it travels down a fiber when light pulses launched close together.

"
    ::= { ifPerfL0Entry 7 }

ifPerfL0DifferentialGroupDelay OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The arrival time difference between two polarization states at
         the output of the media (fiber).

"
    ::= { ifPerfL0Entry 8 }

ifPerfL0InitialDifferentialGroupDelay OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The initial received differential group delay in units of picoseconds.
         The value is set using the install command.

"
    ::= { ifPerfL0Entry 9 }

ifPerfL0UpId OBJECT-TYPE
    SYNTAX      Unsigned32   (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
    "Identity in the UP for the Perf Admin entry
"
    DEFVAL { 0  }
    ::= { ifPerfL0Entry 10 }


ifPerfL0OpticalSNR OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OSNR of the received signal (dB/0.1nm) reported by the coherent module receiver.

"
    ::= { ifPerfL0Entry 11 }

ifPerfL0QFactor OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Pre-FEC Q factor (dB).

"
    ::= { ifPerfL0Entry 12 }

-- ----------------------------------------------------
-- IfPerfL2Stat L2 group
-- ----------------------------------------------------

ifPerfL2StatTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfPerfL2StatEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The  ifPerfL2Stat performance group contains information and
         configuration for all ifPerfL2Stat performance objects."

    ::= { ifPerfL2StatList 1 }

ifPerfL2StatEntry OBJECT-TYPE
    SYNTAX      IfPerfL2StatEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the ifPerfL2Stat list.

"
    INDEX { ifPerfL2StatIndex }
    ::= { ifPerfL2StatTable 1 }

IfPerfL2StatEntry ::=
    SEQUENCE {
        ifPerfL2StatIndex                  Unsigned32,
        ifPerfL2StatName                   MgmtNameString,
        ifPerfL2StatConnIfPerfAdminIfIndex Unsigned32WithNA,
        ifPerfL2StatPeriod                 PerfPeriodWithNA,
        ifPerfL2StatType                   L2MeasurementTypeWithNA,

        -- Ethernet traffic data
        ifPerfL2StatCurrentFrames          Counter64,
        ifPerfL2StatCurrentBytes           Counter64,
        ifPerfL2StatCurrentUnicastFrames   Counter64,
        ifPerfL2StatCurrentMulticastFrames Counter64,
        ifPerfL2StatCurrentBroadcastFrames Counter64,
        ifPerfL2StatMaxUtilization         Unsigned32WithNA,
        ifPerfL2StatAverageUtilization     Unsigned32WithNA,
        ifPerfL2StatCurrentUtilization     Unsigned32WithNA }

ifPerfL2StatIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index assigned to each entry.

"
    ::= { ifPerfL2StatEntry 1 }

ifPerfL2StatName OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The management name of the performance object,
        for example 'clientL2:1:2:1-2', where the first number indicates
        subrack, the second slot number and the third/fourth
        are the physical port numbers.

"
    ::= { ifPerfL2StatEntry 2 }

ifPerfL2StatConnIfPerfAdminIfIndex OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index that describes to which index in ifPerfAdminIf table
        this object is related.

"
    ::= { ifPerfL2StatEntry 3 }

ifPerfL2StatPeriod OBJECT-TYPE
    SYNTAX      PerfPeriodWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Period, 15 minute or 24 hour.
        - 15 minute interval measurements per
        measurement point

        - 24 hour interval measurements per
        measurement point

"
    ::= { ifPerfL2StatEntry 4 }

ifPerfL2StatType OBJECT-TYPE
    SYNTAX      L2MeasurementTypeWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The direction type of signal the interface expects.

        rx - Only ingoing signal.

        tx - Only outgoing signal.

"
    ::= { ifPerfL2StatEntry 5 }

ifPerfL2StatCurrentFrames OBJECT-TYPE
     SYNTAX     Counter64
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
        "The amount of Ethernet frames during a particular interval.

"
    ::= { ifPerfL2StatEntry 6 }

ifPerfL2StatCurrentBytes OBJECT-TYPE
     SYNTAX     Counter64
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
        "The amount of bytes during a particular interval.

"
    ::= { ifPerfL2StatEntry 7 }

ifPerfL2StatCurrentUnicastFrames OBJECT-TYPE
     SYNTAX Counter64
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
        "The amount of Ethernet unicast frames during a
        particular interval.

"
    ::= { ifPerfL2StatEntry 8 }

ifPerfL2StatCurrentMulticastFrames OBJECT-TYPE
     SYNTAX Counter64
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
        "The amount of Ethernet multicast frames during a
        particular interval.

"
    ::= { ifPerfL2StatEntry 9 }

ifPerfL2StatCurrentBroadcastFrames OBJECT-TYPE
     SYNTAX Counter64
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
        "The amount of Ethernet broadcast frames during a
        particular interval.

"
    ::= { ifPerfL2StatEntry 10 }

ifPerfL2StatMaxUtilization OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The maximum bandwidth utilization of the received or
         transmitted signal during a particular 15 minute or
         24 hour interval.

"
    ::= { ifPerfL2StatEntry 11 }

ifPerfL2StatAverageUtilization OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The average bandwidth utilization of the received or
         transmitted signal during a particular 15 minute or
         24 hour interval.

"
    ::= { ifPerfL2StatEntry 12 }

ifPerfL2StatCurrentUtilization OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Current bandwidth utilization of the received or
         transmitted signal during a particular 15 minute or
         24 hour interval.

"
    ::= { ifPerfL2StatEntry 13 }

-- ----------------------------------------------------
-- IfPerfL2Error L2 group
-- ----------------------------------------------------

ifPerfL2ErrorTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfPerfL2ErrorEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The  ifPerfL2Error performance group contains information and
         configuration for all ifPerfL2Error performance objects."

    ::= { ifPerfL2ErrorList 1 }

ifPerfL2ErrorEntry OBJECT-TYPE
    SYNTAX      IfPerfL2ErrorEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the ifPerfL2Error list.

"
    INDEX { ifPerfL2ErrorIndex }
    ::= { ifPerfL2ErrorTable 1 }

IfPerfL2ErrorEntry ::=
    SEQUENCE {
        ifPerfL2ErrorIndex                  Unsigned32,
        ifPerfL2ErrorName                   MgmtNameString,
        ifPerfL2ErrorConnIfPerfAdminIfIndex Unsigned32WithNA,
        ifPerfL2ErrorPeriod                 PerfPeriodWithNA,
        ifPerfL2ErrorType                   L2MeasurementTypeWithNA,

        -- Ethernet traffic data
        ifPerfL2ErrorCurrentUndersizedFrames Counter64,
        ifPerfL2ErrorCurrentOversizedFrames Counter64,
        ifPerfL2ErrorCurrentFragments       Counter64,
        ifPerfL2ErrorCurrentFcsErrors       Counter64,

        -- Ethernet traffic thresholds
        ifPerfL2ErrorUndersizedFramesThreshold Counter64,
        ifPerfL2ErrorOversizedFramesThreshold Counter64,
        ifPerfL2ErrorFragmentsThreshold     Counter64,
        ifPerfL2ErrorFcsErrorsThreshold     Counter64,

        -- Ethernet traffic fault statuses
        ifPerfL2ErrorUndersizedFramesFault  FaultStatusWithNA,
        ifPerfL2ErrorOversizedFramesFault   FaultStatusWithNA,
        ifPerfL2ErrorFragmentsFault         FaultStatusWithNA,
        ifPerfL2ErrorFcsErrorsFault         FaultStatusWithNA }

ifPerfL2ErrorIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index assigned to each entry.

"
    ::= { ifPerfL2ErrorEntry 1 }

ifPerfL2ErrorName OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The management name of the performance object,
        for example 'clientL2:1:2:1-2', where the first number indicates
        subrack, the second slot number and the third/fourth
        are the physical port numbers.

"
    ::= { ifPerfL2ErrorEntry 2 }

ifPerfL2ErrorConnIfPerfAdminIfIndex OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index that describes to which index in ifPerfAdminIf table
        this object is related.

"
    ::= { ifPerfL2ErrorEntry 3 }

ifPerfL2ErrorPeriod OBJECT-TYPE
    SYNTAX      PerfPeriodWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Period, 15 minute or 24 hour.
        - 15 minute interval measurements per
        measurement point

        - 24 hour interval measurements per
        measurement point

"
    ::= { ifPerfL2ErrorEntry 4 }

ifPerfL2ErrorType OBJECT-TYPE
    SYNTAX      L2MeasurementTypeWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The direction type of signal the interface expects.

        rx - Only ingoing signal.

        tx - Only outgoing signal.

"
    ::= { ifPerfL2ErrorEntry 5 }

ifPerfL2ErrorCurrentUndersizedFrames OBJECT-TYPE
     SYNTAX Counter64
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
        "The amount of undersized Ethernet frames during a
        particular interval.

"
    ::= { ifPerfL2ErrorEntry 6 }

ifPerfL2ErrorCurrentOversizedFrames OBJECT-TYPE
     SYNTAX Counter64
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
        "The amount of oversized Ethernet frames during a
        particular interval.
        Frames with a length over 9600 bytes are counted
        as oversized frames.

"
    ::= { ifPerfL2ErrorEntry 7 }

ifPerfL2ErrorCurrentFragments OBJECT-TYPE
     SYNTAX Counter64
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
        "The amount of fragmented Ethernet frames during a
        particular interval.

"
    ::= { ifPerfL2ErrorEntry 8 }

ifPerfL2ErrorCurrentFcsErrors OBJECT-TYPE
     SYNTAX Counter64
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
        "The amount of Ethernet frames with FCS or alignment
        errors during a particular interval.

"
    ::= { ifPerfL2ErrorEntry 9 }

ifPerfL2ErrorUndersizedFramesThreshold  OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Sets the threshold for the undersized frames alarm.

"
    DEFVAL { 10 }
    ::= { ifPerfL2ErrorEntry 10 }

ifPerfL2ErrorOversizedFramesThreshold  OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Sets the threshold for the oversized frames alarm.
        A value 0 (zero) will disable the alarm.

"
    DEFVAL { 10 }
    ::= { ifPerfL2ErrorEntry 11 }

ifPerfL2ErrorFragmentsThreshold  OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Sets the threshold for the fragmented frames alarm.

"
    DEFVAL { 10 }
    ::= { ifPerfL2ErrorEntry 12 }

ifPerfL2ErrorFcsErrorsThreshold  OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Sets the threshold for the FCS errors alarm.

"
    DEFVAL { 10 }
    ::= { ifPerfL2ErrorEntry 13 }

ifPerfL2ErrorUndersizedFramesFault  OBJECT-TYPE
    SYNTAX      FaultStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Undersized frames threshold exceeded.

        alarm: The number of undersized frames during a
        period exceeds the associated threshold.

        ok: At the start of a new period the associated
        undersized frames counter is reset to zero.
        At the same time the fault status is cleared.

"

    ::= { ifPerfL2ErrorEntry 14 }

ifPerfL2ErrorOversizedFramesFault OBJECT-TYPE
    SYNTAX      FaultStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Oversized frames threshold exceeded.

        alarm: The number of oversized frames during a
        period exceeds the associated threshold.

        ok: At the start of a new period the associated
        oversized frames counter is reset to zero.
        At the same time the fault status is cleared.

"
    ::= { ifPerfL2ErrorEntry 15 }

ifPerfL2ErrorFragmentsFault  OBJECT-TYPE
    SYNTAX      FaultStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Fragments threshold exceeded.

        alarm: The number of fragmented frames during a
        period exceeds the associated threshold.

        ok: At the start of a new period the associated
        fragmented frames counter is reset to zero.
        At the same time the fault status is cleared.

"
    ::= { ifPerfL2ErrorEntry 16 }

ifPerfL2ErrorFcsErrorsFault  OBJECT-TYPE
    SYNTAX      FaultStatusWithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "FCS errors threshold exceeded.

        alarm: The number of FCS or alignment errors during a
        period exceeds the associated threshold.

        ok: At the start of a new period the associated
        FCS error counter is reset to zero.
        At the same time the fault status is cleared.

"
    ::= { ifPerfL2ErrorEntry 17 }

-- ----------------------------------------------------
-- Delay measurement group
-- ----------------------------------------------------

ifPerfDelayTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfPerfDelayEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Delay group group contains information and
         configuration for the delay measurment of line ports."

    ::= { ifPerfDelayList 1 }

ifPerfDelayEntry OBJECT-TYPE
    SYNTAX      IfPerfDelayEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the ifPerf Delay list.

"
    INDEX { ifPerfDelayIndex }
    ::= { ifPerfDelayTable 1 }

IfPerfDelayEntry ::=
    SEQUENCE {
        ifPerfDelayIndex                   Unsigned32,
        ifPerfDelayUId                     Unsigned32,
        ifPerfDelayName                    MgmtNameString,
        ifPerfDelayTwoWayFiberDelay        Unsigned32WithNA,
        ifPerfDelayConnIfPerfAdminIfIndex  Unsigned32WithNA}

ifPerfDelayIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index assigned to each entry.

"
    ::= { ifPerfDelayEntry 1 }

ifPerfDelayUId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An unique identifier assigned to each entry.

"
    ::= { ifPerfDelayEntry 2 }

ifPerfDelayName OBJECT-TYPE
    SYNTAX      MgmtNameString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The management name of the object,
        for example 'delay:1:2:1-2', where the first number indicates
        subrack, the second slot number and the third/fourth
        are the physical port numbers.

"
    ::= { ifPerfDelayEntry 3 }

ifPerfDelayTwoWayFiberDelay OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The measured delay in ns.

"
    ::= { ifPerfDelayEntry 4 }

ifPerfDelayConnIfPerfAdminIfIndex OBJECT-TYPE
    SYNTAX      Unsigned32WithNA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index that describes to which index in ifPerfAdminIf table
        this object is related.

"
    ::= { ifPerfDelayEntry 5 }

-- ----------------------------------------------------
-- Notifications
-- ----------------------------------------------------


-- ----------------------------------------------------
-- Object and event groups
-- ----------------------------------------------------

ifPerfGeneralGroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfGeneralConfigLastChangeTime,
        ifPerfGeneralStateLastChangeTime,
        ifPerfGeneralAdminTableSize,
        ifPerfGeneralAdminConfigLastChangeTime,
        ifPerfGeneralAdminStateLastChangeTime,
        ifPerfGeneralFecTableSize,
        ifPerfGeneralFecConfigLastChangeTime,
        ifPerfGeneralFecStateLastChangeTime,
        ifPerfGeneralG826TableSize,
        ifPerfGeneralG826ConfigLastChangeTime,
        ifPerfGeneralG826StateLastChangeTime,
        ifPerfGeneralL1TableSize,
        ifPerfGeneralL1ConfigLastChangeTime,
        ifPerfGeneralL1StateLastChangeTime,
        ifPerfGeneralL0TableSize,
        ifPerfGeneralL0ConfigLastChangeTime,
        ifPerfGeneralL0StateLastChangeTime }
    STATUS      deprecated
    DESCRIPTION
        "The general objects."
    ::= { lumIfPerfGroups 1 }

ifPerfAdminGroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfAdminIndex,
        ifPerfAdminName,
        ifPerfAdminConnIfBasicIfIndex,
        ifPerfAdminAdminStatus,
        ifPerfAdminReportMode,
        ifPerfAdminOperStatus,
        ifPerfAdminIsSuspect15m,
        ifPerfAdminIsSuspect24h,
        ifPerfAdminReset15m,
        ifPerfAdminReset24h}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfAdmin objects."
    ::= { lumIfPerfGroups 2 }

ifPerfFecGroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfFecIndex,
        ifPerfFecName,
        ifPerfFecConnIfPerfAdminIfIndex,
        ifPerfFecCorrectedZeros,
        ifPerfFecCorrectedOnes,
        ifPerfFecRxBerEstimation,
        ifPerfFecRxAvgPreFecBer}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfFec objects."
    ::= { lumIfPerfGroups 3 }


ifPerfG826GroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfG826Index,
        ifPerfG826Name,
        ifPerfG826ConnIfPerfAdminIfIndex,
        ifPerfG826Period,
        ifPerfG826Type,
        ifPerfG826MonitorLevel,
        ifPerfG826MonitorChannel,
        ifPerfG826CounterEs,
        ifPerfG826CounterSes,
        ifPerfG826CounterUas,
        ifPerfG826CounterBbe,
        ifPerfG826ThresholdEs,
        ifPerfG826ThresholdSes,
        ifPerfG826ThresholdUas,
        ifPerfG826ThresholdBbe,
        ifPerfG826FaultStatusEs,
        ifPerfG826FaultStatusSes,
        ifPerfG826FaultStatusUas,
        ifPerfG826FaultStatusBbe}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfG826 objects."
    ::= { lumIfPerfGroups 4 }

ifPerfL1GroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfL1Index,
        ifPerfL1Name,
        ifPerfL1ConnIfPerfAdminIfIndex,
        ifPerfL1Period,
        ifPerfL1Type,
        ifPerfL1MaxUtilization,
        ifPerfL1AverageUtilization }
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfL1 objects."
    ::= { lumIfPerfGroups 5 }

ifPerfL0GroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfL0Index,
        ifPerfL0Name,
        ifPerfL0ConnIfPerfAdminIfIndex,
        ifPerfL0RxPower,
        ifPerfL0TxPower,
        ifPerfL0InitialRxPower }
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfL0 objects."
    ::= { lumIfPerfGroups 6 }

ifPerfGeneralGroupV2 OBJECT-GROUP
    OBJECTS {
        ifPerfGeneralConfigLastChangeTime,
        ifPerfGeneralStateLastChangeTime,
        ifPerfGeneralAdminTableSize,
        ifPerfGeneralAdminConfigLastChangeTime,
        ifPerfGeneralAdminStateLastChangeTime,
        ifPerfGeneralFecTableSize,
        ifPerfGeneralFecConfigLastChangeTime,
        ifPerfGeneralFecStateLastChangeTime,
        ifPerfGeneralG826TableSize,
        ifPerfGeneralG826ConfigLastChangeTime,
        ifPerfGeneralG826StateLastChangeTime,
        ifPerfGeneralL1TableSize,
        ifPerfGeneralL1ConfigLastChangeTime,
        ifPerfGeneralL1StateLastChangeTime,
        ifPerfGeneralL0TableSize,
        ifPerfGeneralL0ConfigLastChangeTime,
        ifPerfGeneralL0StateLastChangeTime,
        ifPerfGeneralL2StatTableSize,
        ifPerfGeneralL2StatConfigLastChangeTime,
        ifPerfGeneralL2StatStateLastChangeTime,
        ifPerfGeneralL2ErrorTableSize,
        ifPerfGeneralL2ErrorConfigLastChangeTime,
        ifPerfGeneralL2ErrorStateLastChangeTime }
    STATUS      deprecated
    DESCRIPTION
        "The general objects."
    ::= { lumIfPerfGroups 7 }

ifPerfL2StatGroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfL2StatIndex,
        ifPerfL2StatName,
        ifPerfL2StatConnIfPerfAdminIfIndex,
        ifPerfL2StatPeriod,
        ifPerfL2StatType,
        ifPerfL2StatCurrentFrames,
        ifPerfL2StatCurrentBytes,
        ifPerfL2StatCurrentUnicastFrames,
        ifPerfL2StatCurrentMulticastFrames,
        ifPerfL2StatCurrentBroadcastFrames }
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfL2Stat objects."
    ::= { lumIfPerfGroups 8 }

ifPerfL1GroupV2 OBJECT-GROUP
    OBJECTS {
        ifPerfL1Index,
        ifPerfL1Name,
        ifPerfL1ConnIfPerfAdminIfIndex,
        ifPerfL1Period,
        ifPerfL1Type,
        ifPerfL1MaxUtilization,
        ifPerfL1AverageUtilization,
        ifPerfL1CurrentUtilization }
    STATUS      current
    DESCRIPTION
        "The ifPerfL2 objects."
    ::= { lumIfPerfGroups 9 }

ifPerfL0GroupV2 OBJECT-GROUP
    OBJECTS {
        ifPerfL0Index,
        ifPerfL0Name,
        ifPerfL0ConnIfPerfAdminIfIndex,
        ifPerfL0RxPower,
        ifPerfL0TxPower,
        ifPerfL0InitialRxPower,
        ifPerfL0ChromaticDispersion,
        ifPerfL0DifferentialGroupDelay,
        ifPerfL0InitialDifferentialGroupDelay}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfL0 objects."
    ::= { lumIfPerfGroups 10 }

ifPerfL2ErrorGroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfL2ErrorIndex,
        ifPerfL2ErrorName,
        ifPerfL2ErrorConnIfPerfAdminIfIndex,
        ifPerfL2ErrorPeriod,
        ifPerfL2ErrorType,
        ifPerfL2ErrorCurrentUndersizedFrames,
        ifPerfL2ErrorCurrentOversizedFrames,
        ifPerfL2ErrorCurrentFragments,
        ifPerfL2ErrorCurrentFcsErrors,
        ifPerfL2ErrorUndersizedFramesThreshold,
        ifPerfL2ErrorOversizedFramesThreshold,
        ifPerfL2ErrorFragmentsThreshold,
        ifPerfL2ErrorFcsErrorsThreshold,
        ifPerfL2ErrorUndersizedFramesFault,
        ifPerfL2ErrorOversizedFramesFault,
        ifPerfL2ErrorFragmentsFault,
        ifPerfL2ErrorFcsErrorsFault }
    STATUS      current
    DESCRIPTION
        "The ifPerfL2Error objects."
    ::= { lumIfPerfGroups 11 }

ifPerfFecGroupV2 OBJECT-GROUP
    OBJECTS {
        ifPerfFecIndex,
        ifPerfFecName,
        ifPerfFecConnIfPerfAdminIfIndex,
        ifPerfFecCorrectedZeros,
        ifPerfFecCorrectedOnes,
        ifPerfFecRxBerEstimation,
        ifPerfFecRxAvgPreFecBer,
        ifPerfFecCorrectedBits}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfFec objects."
    ::= { lumIfPerfGroups 12 }

ifPerfFecGroupV3 OBJECT-GROUP
    OBJECTS {
        ifPerfFecIndex,
        ifPerfFecName,
        ifPerfFecConnIfPerfAdminIfIndex,
        ifPerfFecCorrectedZeros,
        ifPerfFecCorrectedOnes,
        ifPerfFecRxBerEstimation,
        ifPerfFecRxAvgPreFecBer,
        ifPerfFecCorrectedBits,
        ifPerfFecRxBitErrorEstimation}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfFec objects."
    ::= { lumIfPerfGroups 13 }

ifPerfAdminGroupV2 OBJECT-GROUP
    OBJECTS {
        ifPerfAdminIndex,
        ifPerfAdminName,
        ifPerfAdminConnIfBasicIfIndex,
        ifPerfAdminAdminStatus,
        ifPerfAdminReportMode,
        ifPerfAdminOperStatus,
        ifPerfAdminIsSuspect15m,
        ifPerfAdminIsSuspect24h,
        ifPerfAdminReset15m,
        ifPerfAdminReset24h,
        ifPerfAdminUpId}
    STATUS      current
    DESCRIPTION
        "The ifPerfAdmin objects. (R26)"
    ::= { lumIfPerfGroups 14 }

ifPerfG826GroupV2 OBJECT-GROUP
    OBJECTS {
        ifPerfG826Index,
        ifPerfG826Name,
        ifPerfG826ConnIfPerfAdminIfIndex,
        ifPerfG826Period,
        ifPerfG826Type,
        ifPerfG826MonitorLevel,
        ifPerfG826MonitorChannel,
        ifPerfG826CounterEs,
        ifPerfG826CounterSes,
        ifPerfG826CounterUas,
        ifPerfG826CounterBbe,
        ifPerfG826ThresholdEs,
        ifPerfG826ThresholdSes,
        ifPerfG826ThresholdUas,
        ifPerfG826ThresholdBbe,
        ifPerfG826FaultStatusEs,
        ifPerfG826FaultStatusSes,
        ifPerfG826FaultStatusUas,
        ifPerfG826FaultStatusBbe,
        ifPerfG826UpId}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfG826 objects."
    ::= { lumIfPerfGroups 15 }

ifPerfL2StatGroupV2 OBJECT-GROUP
    OBJECTS {
        ifPerfL2StatIndex,
        ifPerfL2StatName,
        ifPerfL2StatConnIfPerfAdminIfIndex,
        ifPerfL2StatPeriod,
        ifPerfL2StatType,
        ifPerfL2StatCurrentFrames,
        ifPerfL2StatCurrentBytes,
        ifPerfL2StatCurrentUnicastFrames,
        ifPerfL2StatCurrentMulticastFrames,
        ifPerfL2StatCurrentBroadcastFrames,
        ifPerfL2StatMaxUtilization,
        ifPerfL2StatAverageUtilization,
        ifPerfL2StatCurrentUtilization }
    STATUS      current
    DESCRIPTION
        "The ifPerfL2Stat objects."
    ::= { lumIfPerfGroups 16 }

ifPerfFecGroupV4 OBJECT-GROUP
    OBJECTS {
        ifPerfFecIndex,
        ifPerfFecName,
        ifPerfFecConnIfPerfAdminIfIndex,
        ifPerfFecCorrectedZeros,
        ifPerfFecCorrectedOnes,
        ifPerfFecRxBerEstimation,
        ifPerfFecRxAvgPreFecBer,
        ifPerfFecCorrectedBits,
        ifPerfFecRxBitErrorEstimation,
        ifPerfFecOpticalSNR }
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfFec objects."
    ::= { lumIfPerfGroups 17 }

ifPerfL0GroupV3 OBJECT-GROUP
    OBJECTS {
        ifPerfL0Index,
        ifPerfL0Name,
        ifPerfL0ConnIfPerfAdminIfIndex,
        ifPerfL0RxPower,
        ifPerfL0TxPower,
        ifPerfL0InitialRxPower,
        ifPerfL0ChromaticDispersion,
        ifPerfL0DifferentialGroupDelay,
        ifPerfL0InitialDifferentialGroupDelay,
        ifPerfL0UpId}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfL0 objects."
    ::= { lumIfPerfGroups 18 }

ifPerfFecGroupV5 OBJECT-GROUP
    OBJECTS {
        ifPerfFecIndex,
        ifPerfFecName,
        ifPerfFecConnIfPerfAdminIfIndex,
        ifPerfFecCorrectedZeros,
        ifPerfFecCorrectedOnes,
        ifPerfFecRxBerEstimation,
        ifPerfFecRxAvgPreFecBer,
        ifPerfFecCorrectedBits,
        ifPerfFecRxBitErrorEstimation,
        ifPerfFecOpticalSNR,
        ifPerfFecUpId}
    STATUS      deprecated
    DESCRIPTION
        "The ifPerfFec objects."
    ::= { lumIfPerfGroups 19 }

ifPerfGeneralGroupV3 OBJECT-GROUP
    OBJECTS {
        ifPerfGeneralConfigLastChangeTime,
        ifPerfGeneralStateLastChangeTime,
        ifPerfGeneralAdminTableSize,
        ifPerfGeneralAdminConfigLastChangeTime,
        ifPerfGeneralAdminStateLastChangeTime,
        ifPerfGeneralFecTableSize,
        ifPerfGeneralFecConfigLastChangeTime,
        ifPerfGeneralFecStateLastChangeTime,
        ifPerfGeneralG826TableSize,
        ifPerfGeneralG826ConfigLastChangeTime,
        ifPerfGeneralG826StateLastChangeTime,
        ifPerfGeneralL1TableSize,
        ifPerfGeneralL1ConfigLastChangeTime,
        ifPerfGeneralL1StateLastChangeTime,
        ifPerfGeneralL0TableSize,
        ifPerfGeneralL0ConfigLastChangeTime,
        ifPerfGeneralL0StateLastChangeTime,
        ifPerfGeneralL2StatTableSize,
        ifPerfGeneralL2StatConfigLastChangeTime,
        ifPerfGeneralL2StatStateLastChangeTime,
        ifPerfGeneralL2ErrorTableSize,
        ifPerfGeneralL2ErrorConfigLastChangeTime,
        ifPerfGeneralL2ErrorStateLastChangeTime,
        ifPerfGeneralDelayTableSize,
        ifPerfGeneralDelayConfigLastChangeTime,
        ifPerfGeneralDelayStateLastChangeTime }
    STATUS      current
    DESCRIPTION
        "The general objects."
    ::= { lumIfPerfGroups 20 }

ifPerfDelayGroupV1 OBJECT-GROUP
    OBJECTS {
        ifPerfDelayIndex,
        ifPerfDelayUId,
        ifPerfDelayName,
        ifPerfDelayTwoWayFiberDelay }

    STATUS      deprecated
    DESCRIPTION
        "The Delay objects."
    ::= { lumIfPerfGroups 21 }

ifPerfDelayGroupV2 OBJECT-GROUP
    OBJECTS {
        ifPerfDelayIndex,
        ifPerfDelayUId,
        ifPerfDelayName,
        ifPerfDelayTwoWayFiberDelay,
        ifPerfDelayConnIfPerfAdminIfIndex }

    STATUS      current
    DESCRIPTION
        "The Delay objects."
    ::= { lumIfPerfGroups 22 }

ifPerfFecGroupV6 OBJECT-GROUP
    OBJECTS {
        ifPerfFecIndex,
        ifPerfFecName,
        ifPerfFecConnIfPerfAdminIfIndex,
        ifPerfFecCorrectedZeros,
        ifPerfFecCorrectedOnes,
        ifPerfFecRxBerEstimation,
        ifPerfFecRxAvgPreFecBer,
        ifPerfFecCorrectedBits,
        ifPerfFecRxBitErrorEstimation,
        ifPerfFecOpticalSNR,
        ifPerfFecUpId,
        ifPerfFecQMargin,
        ifPerfFecPreFecBer}
    STATUS      current
    DESCRIPTION
        "The ifPerfFec objects."
    ::= { lumIfPerfGroups 23 }

ifPerfL0GroupV4 OBJECT-GROUP
    OBJECTS {
        ifPerfL0Index,
        ifPerfL0Name,
        ifPerfL0ConnIfPerfAdminIfIndex,
        ifPerfL0RxPower,
        ifPerfL0TxPower,
        ifPerfL0InitialRxPower,
        ifPerfL0ChromaticDispersion,
        ifPerfL0DifferentialGroupDelay,
        ifPerfL0InitialDifferentialGroupDelay,
        ifPerfL0OpticalSNR,
        ifPerfL0UpId,
        ifPerfL0QFactor}
    STATUS      current
    DESCRIPTION
        "The ifPerfL0 objects."
    ::= { lumIfPerfGroups 24 }

    ifPerfG826GroupV3 OBJECT-GROUP
        OBJECTS {
            ifPerfG826Index,
            ifPerfG826Name,
            ifPerfG826ConnIfPerfAdminIfIndex,
            ifPerfG826Period,
            ifPerfG826Type,
            ifPerfG826MonitorLevel,
            ifPerfG826MonitorChannel,
            ifPerfG826CounterEs,
            ifPerfG826CounterSes,
            ifPerfG826CounterUas,
            ifPerfG826CounterBbe,
            ifPerfG826ThresholdEs,
            ifPerfG826ThresholdSes,
            ifPerfG826ThresholdUas,
            ifPerfG826ThresholdBbe,
            ifPerfG826FaultStatusEs,
            ifPerfG826FaultStatusSes,
            ifPerfG826FaultStatusUas,
            ifPerfG826FaultStatusBbe,
            ifPerfG826UpId,
            ifPerfG826TribPortId}
        STATUS      current
        DESCRIPTION
            "The ifPerfG826 objects."
        ::= { lumIfPerfGroups 25 }

-- ----------------------------------------------------
-- Compliance
-- ----------------------------------------------------

lumIfPerfComplV1 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB."
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV1,
            ifPerfAdminGroupV1,
            ifPerfFecGroupV1,
            ifPerfG826GroupV1,
            ifPerfL1GroupV1,
            ifPerfL0GroupV1 }
    ::= { lumIfPerfCompl 1 }

lumIfPerfComplV2 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB."
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV1,
            ifPerfFecGroupV1,
            ifPerfG826GroupV1,
            ifPerfL1GroupV1,
            ifPerfL0GroupV1,
            ifPerfL2StatGroupV1 }
    ::= { lumIfPerfCompl 2 }

lumIfPerfComplV3 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB."
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV1,
            ifPerfFecGroupV1,
            ifPerfG826GroupV1,
            ifPerfL1GroupV2,
            ifPerfL0GroupV1,
            ifPerfL2StatGroupV1 }
    ::= { lumIfPerfCompl 3 }

lumIfPerfComplV4 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB."
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV1,
            ifPerfFecGroupV1,
            ifPerfG826GroupV1,
            ifPerfL1GroupV2,
            ifPerfL0GroupV2,
            ifPerfL2StatGroupV1 }
    ::= { lumIfPerfCompl 4 }

lumIfPerfComplV5 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB."
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV1,
            ifPerfFecGroupV1,
            ifPerfG826GroupV1,
            ifPerfL1GroupV2,
            ifPerfL0GroupV2,
            ifPerfL2StatGroupV1,
            ifPerfL2ErrorGroupV1 }
    ::= { lumIfPerfCompl 5 }

lumIfPerfComplV6 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB."
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV1,
            ifPerfFecGroupV2,
            ifPerfG826GroupV1,
            ifPerfL1GroupV2,
            ifPerfL0GroupV2,
            ifPerfL2StatGroupV1,
            ifPerfL2ErrorGroupV1 }
    ::= { lumIfPerfCompl 6 }

lumIfPerfComplV7 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB."
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV1,
            ifPerfFecGroupV3,
            ifPerfG826GroupV1,
            ifPerfL1GroupV2,
            ifPerfL0GroupV2,
            ifPerfL2StatGroupV1,
            ifPerfL2ErrorGroupV1 }
    ::= { lumIfPerfCompl 7 }

lumIfPerfComplV8 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB. (R26)"
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV2,
            ifPerfFecGroupV4,
            ifPerfG826GroupV2,
            ifPerfL1GroupV2,
            ifPerfL0GroupV2,
            ifPerfL2StatGroupV2,
            ifPerfL2ErrorGroupV1 }
    ::= { lumIfPerfCompl 8 }

lumIfPerfComplV9 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB. (R26)"
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV2,
            ifPerfFecGroupV4,
            ifPerfG826GroupV2,
            ifPerfL1GroupV2,
            ifPerfL0GroupV3,
            ifPerfL2StatGroupV2,
            ifPerfL2ErrorGroupV1 }
    ::= { lumIfPerfCompl 9 }

lumIfPerfComplV10 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB. (R26)"
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV2,
            ifPerfAdminGroupV2,
            ifPerfFecGroupV5,
            ifPerfG826GroupV2,
            ifPerfL1GroupV2,
            ifPerfL0GroupV3,
            ifPerfL2StatGroupV2,
            ifPerfL2ErrorGroupV1 }
    ::= { lumIfPerfCompl 10 }

lumIfPerfComplV11 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB. (R27.1)"
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV3,
            ifPerfAdminGroupV2,
            ifPerfFecGroupV5,
            ifPerfG826GroupV2,
            ifPerfL1GroupV2,
            ifPerfL0GroupV3,
            ifPerfL2StatGroupV2,
            ifPerfL2ErrorGroupV1,
            ifPerfDelayGroupV1 }
    ::= { lumIfPerfCompl 11 }

lumIfPerfComplV12 MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB. (R29)"
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV3,
            ifPerfAdminGroupV2,
            ifPerfFecGroupV5,
            ifPerfG826GroupV2,
            ifPerfL1GroupV2,
            ifPerfL0GroupV3,
            ifPerfL2StatGroupV2,
            ifPerfL2ErrorGroupV1,
            ifPerfDelayGroupV2 }
    ::= { lumIfPerfCompl 12 }


lumIfPerfComplV13 MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "Basic implementation requirements for the ifPerf MIB. (R32.1)"
    MODULE
        MANDATORY-GROUPS {
            ifPerfGeneralGroupV3,
            ifPerfAdminGroupV2,
            ifPerfFecGroupV6,
            ifPerfG826GroupV3,
            ifPerfL1GroupV2,
            ifPerfL0GroupV4,
            ifPerfL2StatGroupV2,
            ifPerfL2ErrorGroupV1,
            ifPerfDelayGroupV2 }
    ::= { lumIfPerfCompl 13 }

END