diff --git a/MIBS/powerwalker/EPPC-MIB b/MIBS/powerwalker/EPPC-MIB
new file mode 100644
index 0000000..3b336f9
--- /dev/null
+++ b/MIBS/powerwalker/EPPC-MIB
@@ -0,0 +1,2360 @@
+-- PPC MIB
+-- ====================================================================
+-- Revision History
+-- v0.13 2011-11-10 Gavin Zhao created, Lilinhua modified
+-- *************************NMC v0.0.1.7***********************************
+-- v0.14 2011-11-18 Lilinhua
+-- 1. Modify string "ppcTrap" to "eppcTrap"
+-- 2012-02-09 Lilinhua
+-- 1. Modify upsESystemFaultCode's description "The warning code of UPS" to "The fault code of UPS".
+-- *************************NMC v1.1.0.4************************************
+-- v0.15 2012-07-20 Lilinhua
+-- 1. upsEShutdownWarningPeriodInterval, modify access from read-only to read-write.
+-- 2. upsEShutdownwarningPeriodTime, add unit second.
+-- 2012-07-31 Lilinhua
+-- 1. Modify upsEBatteryTestElapsedTime's format from hh:mm:ss.ss to hh:mm:ss
+-- 2012-08-09 Lilinhua
+-- 1. Modify values of upsEModuleWorkingMode as upsESystemStatus's.
+-- *************************NMC v1.1.0.6************************************
+-- 2012-08-27 Lilinhua
+-- 1. Modify "Moudles" to "Modules", advised by Beth.
+-- 2. Modify module name as phase name "upsEModuleOutputCurrentR", "upsEModuleOutputWattR", "upsEModuleOutputLoadR".
+-- 3. Add Convert module item "upsEModuleTrapState(12)".
+-- 4. Add Convert module item "upsEModuleConfigOutputVA(13)".
+-- 5. Add Convert module item "upsEModuleOutputCurrentS(14)", "upsEModuleOutputCurrentT(15)".
+-- 6. Add Convert module item "upsEModuleOutputWattS(16)", "upsEModuleOutputWattT(17)".
+-- 7. Add Convert module item "upsEModuleOutputLoadS(18)", "upsEModuleOutputLoadT(19)".
+-- 8. Add Convert module item "upsEModuleOutputVAR(20)", "upsEModuleOutputVAS(21)", "upsEModuleOutputVAT(22)".
+-- 9. Modify upsETrapState max length from 255 to 127.
+-- *************************NMC v1.1.0.6************************************
+-- 2012-08-27 Lilinhua
+-- 1. Modify trap description of Overload, OverTemperature.
+-- *************************NMC v1.3.0.0************************************
+-- 2013-06-21 Lilinhua
+-- 1. Add two upsEShutdownEvents: "belowCapacityLimit(11), belowRemainTimeLimit(12)".
+-- 2. Add 4 traps: upsEBelowCapacityLimit, upsENotBelowCapacityLimit, upsEBelowRemainTimeLimit, upsENotBelowRemainTimeLimit.
+-- 3. Add 2 config data: upsESystemConfigBelowCapacityLimit, upsESystemConfigBelowRemainTimeLimit.
+-- 4. Modify upsETrapState's description: "trap 2(battery on)" to "trap 7(battery on)".
+-- *************************NMC v1.4.0.3************************************
+-- 2014-10-15 Lilinhua
+-- 1. Modify descriptions of "upsEEnvironmentTemperatureHighSetPoint, upsEEnvironmentHumidityHighSetPoint,
+-- upsEEnvironmentTemperatureLowSetPoint, upsEEnvironmentHumidityLowSetPoint".
+-- *************************NMC v1.5.0.4************************************
+-- v0.16 2015-01-05 Lilinhua
+-- 1. Modify MIB for add Load segment.
+
+
+EPPC-MIB DEFINITIONS ::= BEGIN
+ IMPORTS
+ TRAP-TYPE
+ FROM RFC-1215
+ DisplayString
+ FROM SNMPv2-TC
+ OBJECT-TYPE
+ FROM RFC-1212
+ enterprises,Counter, IpAddress
+ FROM RFC1155-SMI
+ PositiveInteger,NonNegativeInteger
+ FROM UPS-MIB;
+
+ppc OBJECT IDENTIFIER ::= { enterprises 935 }
+
+device OBJECT IDENTIFIER ::= { ppc 10 }
+upsAgent OBJECT IDENTIFIER ::= { device 1 }
+
+upsE OBJECT IDENTIFIER ::= { upsAgent 1 }
+upsETraps OBJECT IDENTIFIER ::= { upsAgent 2 }
+upsEIdentity OBJECT IDENTIFIER ::= { upsE 1 }
+upsESystemSummary OBJECT IDENTIFIER ::= { upsE 2 }
+upsEBatterySystem OBJECT IDENTIFIER ::= { upsE 3 }
+upsEPowerConverterSystem OBJECT IDENTIFIER ::= { upsE 4 }
+upsELoadSegment OBJECT IDENTIFIER ::= { upsE 5 }
+upsEEnvironment OBJECT IDENTIFIER ::= { upsE 6 }
+upsEBatteryTest OBJECT IDENTIFIER ::= { upsE 7 }
+upsEControl OBJECT IDENTIFIER ::= { upsE 8 }
+upsETrapControl OBJECT IDENTIFIER ::= { upsE 9 }
+
+--========================================================================
+--upsEIdentity
+--========================================================================
+
+ upsEIdentityManufacturer OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The name of the UPS manufacturer."
+ ::= { upsEIdentity 1 }
+
+ upsEIdentityModel OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The UPS Model designation."
+ ::= { upsEIdentity 2 }
+
+ upsEIdentityUPSFirmwareVerison OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The UPS firmware/software version(s)."
+ ::= { upsEIdentity 3 }
+
+ upsEIndentityUPSSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "optional.
+ Most UPS don't supply the value of UPS serial No."
+ ::= { upsEIdentity 4 }
+
+ upsEIdentityDescription OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "A string to identify the UPS. This object should be
+ set by the administrator."
+ ::= { upsEIdentity 5 }
+
+ upsEIdentityAgentSoftwareVerison OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The Network Management Card software/firmware version.
+ This variable may or may not have the same value as
+ upsEIdentGroupUPSSoftwareVersion in some implementations."
+ ::= { upsEIdentity 6 }
+
+ upsEIdentityAttachedDevices OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "A string identifying the devices attached to the output(s)
+ of the UPS. This object should be set by the administrator"
+ ::= { upsEIdentity 7 }
+
+--========================================================================
+--upsESystemSummary
+--========================================================================
+
+ upsESystemStatus OBJECT-TYPE
+ SYNTAX INTEGER { power-on ( 1 ) , stand-by( 2 ) , by-pass ( 3 ) ,
+ line( 4 ) , battery ( 5 ) , battery-test ( 6 ) , fault ( 7 ) ,
+ converter ( 8 ) , eco ( 9 ) , shutdown ( 10 ) , on-booster ( 11 ) , on-reducer ( 12 ) , other( 13 ) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The indication of UPS system status."
+ ::= { upsESystemSummary 1 }
+
+ upsESystemTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The temperature of UPS presented in 0.1 degree."
+ ::= { upsESystemSummary 2 }
+
+ upsESystemWarningCode OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The warning code of UPS. Please refer the warning table
+ of 'Q6' for details."
+ ::= { upsESystemSummary 3 }
+
+ upsESystemFaultCode OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The fault code of UPS.Please refer the fault code
+ of 'Q6' for details."
+ ::= { upsESystemSummary 4 }
+
+ upsESystemConfigInputVoltage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the nominal input voltage presented in 0.1 V. On those
+ systems which support read-write access to this object, if there is an
+ attempt to set this variable to a value that is not supported,
+ the request must be rejected and the agent shall respond with an
+ appropriate error message, i.e., badValue for SNMPv1, or
+ inconsistentValue for SNMPv2."
+ ::= { upsESystemSummary 5 }
+
+ upsESystemConfigInputFrequence OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The nominal input frequency presented in 0.1 Hz. On those systems which support
+ read-write access to this object, if there is an attempt to
+ set this variable to a value that is not supported, the request
+ must be rejected and the agent shall respond with an appropriate
+ error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2."
+ ::= { upsESystemSummary 6 }
+
+ upsESystemConfigOutputVoltage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the nominal output voltage presented in 0.1V. On those systems
+ which support read-write access to this object, if there is an
+ attempt to set this variable to a value that is not supported,
+ the request must be rejected and the agent shall respond with an
+ appropriate error message, i.e., badValue for SNMPv1, or
+ inconsistentValue for SNMPv2"
+ ::= { upsESystemSummary 7 }
+
+ upsESystemConfigOutputFrequency OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The nominal output frequency presented in 0.1Hz. On those systems which support
+ read-write access to this object, if there is an attempt to set
+ this variable to a value that is not supported, the request must
+ be rejected and the agent shall respond with an appropriate error
+ message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2."
+ ::= { upsESystemSummary 8 }
+
+ upsESystemConfigOutputVA OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
+ ::= { upsESystemSummary 9 }
+
+ upsESystemConfigOutputPower OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the nominal true power rating presented in W ."
+ ::= { upsESystemSummary 10 }
+
+ upsESystemConfigOutputLoadHighSetPoint OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The maximum output load allowed before the load is too high for
+ UPS operation "
+ ::= { upsESystemSummary 11 }
+
+ upsESystemConfigOverTemperatureSetPoint OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The maximum temperature allowed before the UPS
+ operation temperature is too high, presented in 0.1 degree."
+ ::= { upsESystemSummary 12 }
+
+ upsESystemInputSourceNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The present external source of input power."
+ ::= { upsESystemSummary 13 }
+
+ upsESystemInputLineBads OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The number of times the Input was out of tolerance in voltage or frequency.
+ Its value should be initialized 0 after agent restarting. "
+ ::= { upsESystemSummary 14 }
+
+ upsESystemInputNumPhases OBJECT-TYPE
+ SYNTAX PositiveInteger ( 1 .. 3 )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The number of input phase utilized is this device, serves as the table index.
+ This value indicate the device initialized feature."
+ ::= { upsESystemSummary 15 }
+
+ upsESystemInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsSystemInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "A list of input table entries. The number of entries is given by the
+ value of upsESystemInputNumPhase."
+ ::= { upsESystemSummary 16 }
+
+ upsESystemInputEntry OBJECT-TYPE
+ SYNTAX UpsSystemInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular input line."
+ INDEX { upsESystemInputPhase }
+ ::= { upsESystemInputTable 1 }
+
+ UpsSystemInputEntry ::= SEQUENCE {
+ upsESystemInputPhase PositiveInteger,
+ upsESystemInputFrequency NonNegativeInteger,
+ upsESystemInputVoltage NonNegativeInteger,
+ upsESystemInputCurrent NonNegativeInteger,
+ upsESystemInputWatts NonNegativeInteger
+ }
+
+
+ upsESystemInputPhase OBJECT-TYPE
+ SYNTAX PositiveInteger( 1 .. 3 )
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The number of the phase. Serves as index for input table"
+ ::= { upsESystemInputEntry 1 }
+
+
+ upsESystemInputFrequency OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured input frquency from the UPS meters in 0.1Hz."
+ ::= { upsESystemInputEntry 2 }
+
+
+ upsESystemInputVoltage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured input voltage from the UPS meters in 0.1 volts"
+ ::= { upsESystemInputEntry 3 }
+
+
+ upsESystemInputCurrent OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured input mandatory from the UPS meters in 0.1 amps."
+ ::= { upsESystemInputEntry 4 }
+
+
+ upsESystemInputWatts OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured input real power in watts."
+ ::= { upsESystemInputEntry 5 }
+
+ upsESystemOutputNumPhase OBJECT-TYPE
+ SYNTAX PositiveInteger ( 1 .. 3 )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The number of metered output phases, serves as the table index.
+ This value indicate the device initialized feature."
+ ::= { upsESystemSummary 17 }
+
+ upsESystemOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsSystemOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "A list of output table entries. The number of entries is given
+ by the value of upsESystemOutputNumPhase."
+ ::= { upsESystemSummary 18 }
+
+ upsESystemOutputEntry OBJECT-TYPE
+ SYNTAX UpsSystemOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular line."
+ INDEX { upsESystemOutputPhase }
+ ::= { upsESystemOutputTable 1 }
+
+ UpsSystemOutputEntry ::= SEQUENCE {
+ upsESystemOutputPhase PositiveInteger,
+ upsESystemOutputFrequency NonNegativeInteger,
+ upsESystemOutputVoltage NonNegativeInteger,
+ upsESystemOutputCurrent NonNegativeInteger,
+ upsESystemOutputWatts NonNegativeInteger,
+ upsESystemOutputVA NonNegativeInteger,
+ upsESystemOutputLoad NonNegativeInteger
+ }
+
+
+ upsESystemOutputPhase OBJECT-TYPE
+ SYNTAX PositiveInteger ( 1 .. 3 )
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The number of the phase. Serves as index for output table"
+ ::= { upsESystemOutputEntry 1 }
+
+
+ upsESystemOutputFrequency OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured output frequency from the UPS meters in 0.1Hz."
+ ::= { upsESystemOutputEntry 2 }
+
+
+ upsESystemOutputVoltage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured output voltage from the UPS meters in 0.1 volts"
+ ::= { upsESystemOutputEntry 3 }
+
+
+ upsESystemOutputCurrent OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured output mandatory from the UPS meters in 0.1 amps."
+ ::= { upsESystemOutputEntry 4 }
+
+
+ upsESystemOutputWatts OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured output real power in watts."
+ ::= { upsESystemOutputEntry 5 }
+
+ upsESystemOutputVA OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured output real complex power in VA."
+ ::= { upsESystemOutputEntry 6 }
+
+
+ upsESystemOutputLoad OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The UPS output load in percent of rated capacity."
+ ::= { upsESystemOutputEntry 7 }
+
+ upsESystemBypassNumPhase OBJECT-TYPE
+ SYNTAX PositiveInteger ( 1 .. 3 )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The number of bypass phases, serves as the table index.
+ This value indicate the device initialized feature"
+ ::= { upsESystemSummary 19 }
+
+ upsESystemBypassTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsSystemBypassEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "A list of bypass table entries. The number of entries is given by the
+ value of upsESystemBypassNumPhase."
+ ::= { upsESystemSummary 20 }
+
+
+ upsESystemBypassEntry OBJECT-TYPE
+ SYNTAX UpsSystemBypassEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular line."
+ INDEX { upsESystemBypassPhase }
+ ::= { upsESystemBypassTable 1 }
+
+ UpsSystemBypassEntry ::= SEQUENCE {
+ upsESystemBypassPhase PositiveInteger,
+ upsESystemBypassFrequency NonNegativeInteger,
+ upsESystemBypassVoltage NonNegativeInteger,
+ upsESystemBypassCurrent NonNegativeInteger,
+ upsESystemBypassWatts NonNegativeInteger
+ }
+
+
+ upsESystemBypassPhase OBJECT-TYPE
+ SYNTAX PositiveInteger ( 1 .. 3 )
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The number of the phase. Serves as index for bypass table"
+ ::= { upsESystemBypassEntry 1 }
+
+
+ upsESystemBypassFrequency OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured bypass frequency from the UPS meters in 0.1 Hz."
+ ::= { upsESystemBypassEntry 2 }
+
+
+ upsESystemBypassVoltage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured bypass voltage from the UPS meters in 0.1 volts"
+ ::= { upsESystemBypassEntry 3 }
+
+
+ upsESystemBypassCurrent OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured bypass mandatory from the UPS meters in 0.1 amps"
+ ::= { upsESystemBypassEntry 4 }
+
+
+ upsESystemBypassWatts OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured input real power in watts."
+ ::= { upsESystemBypassEntry 5 }
+
+
+ upsESystemConfigBelowCapacityLimit OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The UPS batteries capacity(%) limit for shutdown"
+ ::= { upsESystemSummary 21 }
+
+ upsESystemConfigBelowRemainTimeLimit OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The UPS batteries backup time(minute) limit for shutdown"
+ ::= { upsESystemSummary 22 }
+
+--========================================================================
+--upsEBatterySystem
+--========================================================================
+
+ upsEBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER { unknown ( 1 ) , batteryNormal ( 2 ) , batteryLow ( 3 ) ,
+ batteryDepleted ( 4 ) , batteryDischarging ( 5 ) , batteryFailure ( 6 ) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION " The status of UPS battery, a value of batteryLow indicates
+ that the battery-low status bit has been set from device.
+ A value of batteryDepleted indicates that the UPS will be
+ unable to sustain the present load when and if the utility
+ power is lost (including the possibility that the utility
+ power is mandatoryly absent and the UPS is unable to sustain
+ the output)"
+ ::= { upsEBatterySystem 1 }
+
+ upsESecondsOnBattery OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "If the unit is on battery power, the elapsed time
+ since the UPS last switched to battery power, or the
+ time since the network management subsystem was last
+ restarted, whichever is less. 0 shall be returned
+ if the unit is not on battery power"
+ ::= { upsEBatterySystem 2 }
+
+ upsEBatteryEstimatedMinutesRemaining OBJECT-TYPE
+ SYNTAX PositiveInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "An estimate of the time to battery charge depletion
+ under the present load conditions if the utility power
+ is off and remains off, or if it were to be lost and
+ remain off."
+ ::= { upsEBatterySystem 3 }
+
+ upsEBatteryEstimatedChargeRemaining OBJECT-TYPE
+ SYNTAX Integer32 ( 0 .. 100 )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "An estimate of the battery charge remaining expressed
+ as a percent of full charge"
+ ::= { upsEBatterySystem 4 }
+
+ upsEPositiveBatteryVoltage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the present positive battery voltage in 0.1 Volt DC"
+ ::= { upsEBatterySystem 5 }
+
+ upsENegativeBatteryVoltage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the present negative battery voltage in 0.1 Volt DC"
+ ::= { upsEBatterySystem 6 }
+
+ upsEBatteryCellNumber OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "This object indicate the cell number of each set."
+ ::= { upsEBatterySystem 7 }
+
+ upsEBatteryTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The ambient temperature at or near the UPS Battery
+ casing in 0.1 degree."
+ ::= { upsEBatterySystem 8 }
+
+ upsEBatteryLastReplacedDate OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The date when the Batteries in this UPS were last replaced.
+ The format should be DD/MM/YYYY."
+ ::= { upsEBatterySystem 9 }
+
+ upsEBatteryABMStatus OBJECT-TYPE
+ SYNTAX INTEGER { charge ( 1 ) , float ( 2 ) , rest ( 3 ) ,
+ discharge ( 4 ) , disable ( 5 ) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION " The status of ABM."
+ ::= { upsEBatterySystem 10 }
+
+ upsEChargerModulesNum OBJECT-TYPE
+ SYNTAX NonNegativeInteger ( 0 .. 32 )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The number of charger modules inserted to UPS systems. served
+ as the index of the upsEChargerModulesTable.
+ The default value 0 indicate that the UPS system don't have
+ separate charger module."
+ ::= { upsEBatterySystem 11 }
+
+ upsEChargerModulesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsChargerModulesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "A list of charger modules entries. The number of entries is given
+ by the value of upsEchargerModulesNum."
+ ::= { upsEBatterySystem 12 }
+
+ upsEChargerModulesEntry OBJECT-TYPE
+ SYNTAX UpsChargerModulesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular charger module."
+ INDEX { chargerModulesNum }
+ ::= { upsEChargerModulesTable 1 }
+
+ UpsChargerModulesEntry ::= SEQUENCE {
+ chargerModulesNum PositiveInteger,
+ chargerModulesAddress NonNegativeInteger ,
+ positiveChargeVotlage NonNegativeInteger,
+ negativeChargeVoltage NonNegativeInteger,
+ positiveChargeCurrent NonNegativeInteger,
+ negativeChargeCurrent NonNegativeInteger,
+ chargerModulesTemperature INTEGER,
+ chargerModulesMode INTEGER
+ }
+
+
+ chargerModulesNum OBJECT-TYPE
+ SYNTAX PositiveInteger ( 1 .. 32 )
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The number of charger modules. Serves as index for charger module table"
+ ::= { upsEChargerModulesEntry 1 }
+
+
+ chargerModulesAddress OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Charger Modules' address."
+ ::= { upsEChargerModulesEntry 2 }
+
+
+ positiveChargeVotlage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured positive charger voltage from the UPS meters in 0.1 volts"
+ ::= { upsEChargerModulesEntry 3 }
+
+
+ negativeChargeVoltage OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured nepositive charger voltage from the UPS meters in 0.1 volts"
+ ::= { upsEChargerModulesEntry 4 }
+
+
+ positiveChargeCurrent OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured positive charger mandatory from the UPS meters in in 0.1 amps."
+ ::= { upsEChargerModulesEntry 5 }
+
+
+ negativeChargeCurrent OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured nepositive charger mandatory from the UPS meters in 0.1 amps."
+ ::= { upsEChargerModulesEntry 6 }
+
+
+ chargerModulesTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured charger temperature from the UPS meters in 0.1 degree."
+ ::= { upsEChargerModulesEntry 7 }
+
+
+ chargerModulesMode OBJECT-TYPE
+ SYNTAX INTEGER { powerOn ( 1 ) , standyby ( 2 ) , fault ( 3 ) , shutdown ( 4 ) ,
+ running ( 5 ) , suicide ( 6 ) , unknown ( 7 ) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The working mode of charger modules."
+ ::= { upsEChargerModulesEntry 8 }
+
+--========================================================================
+--upsEPowerConverterSystem
+--========================================================================
+
+ upsEUPSModulesNum OBJECT-TYPE
+ SYNTAX NonNegativeInteger ( 0 .. 32 )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The number of UPS modules inserted to UPS systems.
+ served as the index of the upsEModulesTable.
+ the default value 0 indicate that the UPS system do not
+ have separate UPS module."
+ ::= { upsEPowerConverterSystem 1 }
+
+ upsEModulesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsModulesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "A list of UPS modules entries. The number of entries is
+ given by the value of upsEModulesNum."
+ ::= { upsEPowerConverterSystem 2 }
+
+ upsEModulesEntry OBJECT-TYPE
+ SYNTAX UpsModulesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular upsE module."
+ INDEX { upsEModulesNum }
+ ::= { upsEModulesTable 1 }
+
+ UpsModulesEntry ::= SEQUENCE {
+ upsEModulesNum PositiveInteger,
+ upsEModuleAddress INTEGER,
+ upsEModulePositiveBusVolt NonNegativeInteger,
+ upsEModuleNegativeBusVolt NonNegativeInteger,
+ upsEModuleTemperature INTEGER,
+ upsEModuleWorkingMode INTEGER,
+ upsEModuleOutputCurrentR NonNegativeInteger,
+ upsEModuleOutputWattR NonNegativeInteger,
+ upsEModuleOutputLoadR INTEGER,
+ upsEModuleWarningCode DisplayString,
+ upsEModuleFaultCode DisplayString,
+
+ upsEModuleTrapState DisplayString,
+ upsEModuleConfigOutputVA NonNegativeInteger,
+ upsEModuleOutputCurrentS NonNegativeInteger,
+ upsEModuleOutputCurrentT NonNegativeInteger,
+ upsEModuleOutputWattS NonNegativeInteger,
+ upsEModuleOutputWattT NonNegativeInteger,
+ upsEModuleOutputLoadS INTEGER,
+ upsEModuleOutputLoadT INTEGER,
+ upsEModuleOutputVAR NonNegativeInteger,
+ upsEModuleOutputVAS NonNegativeInteger,
+ upsEModuleOutputVAT NonNegativeInteger
+ }
+
+
+ upsEModulesNum OBJECT-TYPE
+ SYNTAX PositiveInteger ( 1 .. 32 )
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The number of UPS modules. Serves as index for UPS module table"
+ ::= { upsEModulesEntry 1 }
+
+
+ upsEModuleAddress OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "the address of UPS modules."
+ ::= { upsEModulesEntry 2 }
+
+
+ upsEModulePositiveBusVolt OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured positive upsE module voltage from the UPS meters in 0.1 volts"
+ ::= { upsEModulesEntry 3 }
+
+
+ upsEModuleNegativeBusVolt OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured nepositive upsE module voltage from the UPS meters in 0.1 volts"
+ ::= { upsEModulesEntry 4 }
+
+
+ upsEModuleTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured upsE module temperature from the UPS meters in 0.1 degree."
+ ::= { upsEModulesEntry 5 }
+
+
+ upsEModuleWorkingMode OBJECT-TYPE
+ SYNTAX INTEGER {power-on ( 1 ) , stand-by( 2 ) , by-pass ( 3 ) ,
+ line( 4 ) , battery ( 5 ) , battery-test ( 6 ) , fault ( 7 ) ,
+ converter ( 8 ) , eco ( 9 ) , shutdown ( 10 ) , on-booster ( 11 ) , on-reducer ( 12 ) , other( 13 ) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The working mode of UPS modules."
+ ::= { upsEModulesEntry 6 }
+
+
+ upsEModuleOutputCurrentR OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
+ ::= { upsEModulesEntry 7 }
+
+
+ upsEModuleOutputWattR OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
+ ::= { upsEModulesEntry 8 }
+
+
+ upsEModuleOutputLoadR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The output load of UPS modules in %."
+ ::= { upsEModulesEntry 9 }
+
+ upsEModuleWarningCode OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The warning code of ups modules.Please refer the warning table of 'QU,XX' for details."
+ ::= { upsEModulesEntry 10 }
+
+ upsEModuleFaultCode OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The fault code of ups modules.Please refer command 'QU,XX' for details."
+ ::= { upsEModulesEntry 11 }
+
+ upsEModuleTrapState OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 127 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "the values indicate the unrestored traps.
+ For example, after AC fail, so the value of upsETrapState should be '1'.
+ And then the AC restore, the value of upsEModuleTrapState
+ should change to empty."
+ ::= { upsEModulesEntry 12 }
+
+
+ upsEModuleConfigOutputVA OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
+ ::= { upsEModulesEntry 13 }
+
+
+ upsEModuleOutputCurrentS OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
+ ::= { upsEModulesEntry 14 }
+
+ upsEModuleOutputCurrentT OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
+ ::= { upsEModulesEntry 15 }
+
+ upsEModuleOutputWattS OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
+ ::= { upsEModulesEntry 16 }
+
+ upsEModuleOutputWattT OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
+ ::= { upsEModulesEntry 17 }
+
+ upsEModuleOutputLoadS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The output load of UPS modules in %."
+ ::= { upsEModulesEntry 18 }
+
+ upsEModuleOutputLoadT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The output load of UPS modules in %."
+ ::= { upsEModulesEntry 19 }
+
+ upsEModuleOutputVAR OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
+ ::= { upsEModulesEntry 20 }
+
+ upsEModuleOutputVAS OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
+ ::= { upsEModulesEntry 21 }
+
+ upsEModuleOutputVAT OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
+ ::= { upsEModulesEntry 22 }
+
+--========================================================================
+--upsELoadSegment
+--========================================================================
+ upsELoadSegment1OffDelay OBJECT-TYPE
+ -- Valid value is from -1 to 32767
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less.
+ Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will
+ abort the countdown. Read this object will get countdown value of the Load Segment."
+ ::= { upsELoadSegment 1 }
+
+ upsELoadSegment1OnDelay OBJECT-TYPE
+ -- Valid value is from -1 to 32767
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Setting this object will start the Load segment output after the indicated number of seconds,
+ including starting the UPS, if necessary. Setting this object to 0 will cause the startup
+ to occur immediately. Setting this object to -1 will abort the countdown."
+ ::= { upsELoadSegment 2 }
+
+ upsELoadSegment1AutoOffTimer OBJECT-TYPE
+ -- Valid value is from -1 to 32767
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The load segment turns automatically off after the delay while the unit operates on battery,
+ but the shutdown is cancelled if the utility return before the delay has expired."
+ ::= { upsELoadSegment 3 }
+
+ upsELoadSegment1AutoOnTimer OBJECT-TYPE
+ -- Valid value is from -1 to 32767
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The load segment is automatically turned on after a selected delay
+ if it has been shutdown due to on battery."
+ ::= { upsELoadSegment 4 }
+
+ upsELoadSegment1State OBJECT-TYPE
+ SYNTAX INTEGER { off(1), on(2), off-pending(3), on-pending(4), not-support(5) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Load segment output state."
+ ::= { upsELoadSegment 5 }
+
+ upsELoadSegment2OffDelay OBJECT-TYPE
+ -- Valid value is from -1 to 32767
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less.
+ Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will
+ abort the countdown. Read this object will get countdown value of the Load Segment."
+ ::= { upsELoadSegment 6 }
+
+ upsELoadSegment2OnDelay OBJECT-TYPE
+ -- Valid value is from -1 to 32767
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Setting this object will start the Load segment output after the indicated number of seconds,
+ including starting the UPS, if necessary. Setting this object to 0 will cause the startup
+ to occur immediately. Setting this object to -1 will abort the countdown."
+ ::= { upsELoadSegment 7 }
+
+ upsELoadSegment2AutoOffTimer OBJECT-TYPE
+ -- Valid value is from -1 to 32767
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The load segment turns automatically off after the delay while the unit operates on battery,
+ but the shutdown is cancelled if the utility return before the delay has expired."
+ ::= { upsELoadSegment 8 }
+
+ upsELoadSegment2AutoOnTimer OBJECT-TYPE
+ -- Valid value is from -1 to 32767
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The load segment is automatically turned on after a selected delay
+ if it has been shutdown due to on battery."
+ ::= { upsELoadSegment 9 }
+
+ upsELoadSegment2State OBJECT-TYPE
+ SYNTAX INTEGER { off(1), on(2), off-pending(3), on-pending(4), not-support(5) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Load segment output state."
+ ::= { upsELoadSegment 10 }
+
+--========================================================================
+--upsEEnvironment
+--========================================================================
+
+ upsEEnvironmentTemperature OBJECT IDENTIFIER ::= { upsEEnvironment 1 }
+
+ upsEEnvironmentCurrentTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measurement of temperature sensor, in 0.1 degree"
+ ::= { upsEEnvironmentTemperature 1 }
+
+ upsEEnvironmentTemperatureHighSetPoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The set point for high temperature warning, in 0.1 degrees.
+ This value must be greater than upsEEnvironmentTemperatureLowSetPoint,
+ and the least significant digit must be zero."
+ ::= { upsEEnvironmentTemperature 2 }
+
+ upsEEnvironmentTemperatureHighStatus OBJECT-TYPE
+ SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "To enable/disable high set point check with sensor temperature."
+ ::= { upsEEnvironmentTemperature 3 }
+
+ upsEEnvironmentTemperatureLowSetPoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The set point for low temperature warning, in 0.1 degrees.
+ This value must be less than upsEEnvironmentTemperatureHighSetPoint,
+ and the least significant digit must be zero."
+ ::= { upsEEnvironmentTemperature 4 }
+
+ upsEEnvironmentTemperatureLowStatus OBJECT-TYPE
+ SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "To enable/disable low set point check with sensor temperature."
+ ::= { upsEEnvironmentTemperature 5 }
+
+ upsEEnvironmentTemperatureOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The offset to calibrate temperature of EMD, in 0.1 degrees"
+ ::= { upsEEnvironmentTemperature 6 }
+
+ upsEEnvironmentHumidity OBJECT IDENTIFIER ::= { upsEEnvironment 2 }
+
+ upsEEnvironmentCurrentHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The measurement of sensor humidity present in %."
+ ::= { upsEEnvironmentHumidity 1 }
+
+ upsEEnvironmentHumidityHighSetPoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The set point for high humidity warning, in %.
+ This value must be greater than upsEEnvironmentHumidityLowSetPoint."
+ ::= { upsEEnvironmentHumidity 2 }
+
+ upsEEnvironmentHumidityHighStatus OBJECT-TYPE
+ SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "To enable/disable high set point check with emd humidity."
+ ::= { upsEEnvironmentHumidity 3 }
+
+ upsEEnvironmentHumidityLowSetPoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The set point for low humidity warning, in %.
+ This value must be less than upsEEnvironmentHumidityHighSetPoint."
+ ::= { upsEEnvironmentHumidity 4 }
+
+ upsEEnvironmentHumidityLowStatus OBJECT-TYPE
+ SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "To enable/disable high set point check with emd humidity."
+ ::= { upsEEnvironmentHumidity 5 }
+
+ upsEEnvironmentHumidityOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The offset to calibrate humidity of EMD, in %."
+ ::= { upsEEnvironmentHumidity 6 }
+
+ upsEEnvironmentContactsNum OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The number of environment contacts, serves as the table index."
+ ::= { upsEEnvironment 3 }
+
+ upsEEnvironmentContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsEEnvironmentContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "A list of contacts table entries. The number of entries is given by the
+ value of upsEEnvironmentContactsNum"
+ ::= { upsEEnvironment 4 }
+
+ upsEEnvironmentContactEntry OBJECT-TYPE
+ SYNTAX UpsEEnvironmentContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular contact"
+ INDEX { upsEEnvironmentContactIndex }
+ ::= { upsEEnvironmentContactTable 1 }
+
+ UpsEEnvironmentContactEntry ::= SEQUENCE {
+ upsEEnvironmentContactIndex PositiveInteger,
+ upsEEnvironmentContactType INTEGER,
+ upsEEnvironmentContactState INTEGER,
+ upsEEnvironmentContactDescription DisplayString
+ }
+
+
+ upsEEnvironmentContactIndex OBJECT-TYPE
+ SYNTAX PositiveInteger
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The number of environment contacts. Serves as index for environment contact table"
+ ::= { upsEEnvironmentContactEntry 1 }
+
+
+ upsEEnvironmentContactType OBJECT-TYPE
+ SYNTAX INTEGER { normallyOpen ( 1 ) , normallyClosed ( 2 ) , notUsed ( 3 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "operation type"
+ ::= { upsEEnvironmentContactEntry 2 }
+
+
+ upsEEnvironmentContactState OBJECT-TYPE
+ SYNTAX INTEGER { open ( 1 ) , closed ( 2 ) , openWithNotice ( 3 ) , closedWithNotice ( 4 ) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The mandatory status."
+ ::= { upsEEnvironmentContactEntry 3 }
+
+
+ upsEEnvironmentContactDescription OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Description of environment contact."
+ ::= { upsEEnvironmentContactEntry 4 }
+
+--========================================================================
+--upsEBatteryTest
+--========================================================================
+
+ upsEBatteryTestStart OBJECT-TYPE
+ SYNTAX INTEGER { none ( 1 ) , batteryTest10Sec ( 2 ) , batteryTestUntilLow ( 3 ) ,
+ batteryTestWithTime ( 4 ) , cancelBatteryTest ( 5 ) , clearBatteryInfo ( 6 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "This object specify the battery test type and initiate battery test.
+ If battTestWithTime selected, the test time is refer to upsEBatteryTestSettingTime."
+ ::= { upsEBatteryTest 1 }
+
+ upsEBatteryTestSettingTime OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The object specify the test time for battery test in seconds."
+ ::= { upsEBatteryTest 2 }
+
+ upsEBatteryTestResult OBJECT-TYPE
+ SYNTAX INTEGER { idle ( 1 ) , processing ( 2 ) , noFailure ( 3 ) ,
+ failureOrWarning ( 4 ) , notPossible ( 5 ) , testCancel ( 6 ) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "This object indicate the test result of battery."
+ ::= { upsEBatteryTest 3 }
+
+ upsEBatteryTestStartTime OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 19 .. 19 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The value of the time the test in progress was initiated,
+ or, if no test is in progress, the time the previous test
+ was initiated. If the value of upsETestBatteryTestResult
+ is noTestsInitiated(6), upsETestStartTime has the value
+ 01/01/1970 00:00:00."
+ ::= { upsEBatteryTest 4 }
+
+ upsEBatteryTestElapsedTime OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 11 .. 11 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The amount of time in format hh:mm:ss, since the test in progress
+ was initiated, or, if no test is in progress, the previous
+ test took to complete. If the value of upsTestResultsSummary
+ is idle(1), upsTestElapsedTime has the value 00:00:00."
+ ::= { upsEBatteryTest 5 }
+
+
+ upsEBatteryTestScheduleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsBatteryTestScheduleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "This table describes the schedule for automatically battery
+ test."
+ ::= { upsEBatteryTest 6 }
+
+ upsEBatteryTestScheduleEntry OBJECT-TYPE
+ SYNTAX UpsBatteryTestScheduleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to schedule test."
+ INDEX { upsEBatteryTestScheduleIndex }
+ ::= { upsEBatteryTestScheduleTable 1 }
+
+ UpsBatteryTestScheduleEntry ::= SEQUENCE {
+ upsEBatteryTestScheduleIndex PositiveInteger,
+ upsEBatteryTestScheduleDay INTEGER,
+ upsEBatteryTestScheduleTime DisplayString,
+ upsEBatteryTestScheduleType INTEGER,
+ upsEBatteryTestScheduleTestWithTime NonNegativeInteger,
+ upsEBatteryTestScheduleSpecialDay DisplayString
+ }
+
+
+ upsEBatteryTestScheduleIndex OBJECT-TYPE
+ SYNTAX PositiveInteger
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The index of battery test scheduled."
+ ::= { upsEBatteryTestScheduleEntry 1 }
+
+
+ upsEBatteryTestScheduleDay OBJECT-TYPE
+ SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednsday ( 3 ) ,
+ thusday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
+ sunday ( 7 ) , specialday ( 8 ) , none ( 9 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The weekday or specaial day on which the UPS should start battery test."
+ ::= { upsEBatteryTestScheduleEntry 2 }
+
+
+ upsEBatteryTestScheduleTime OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 5 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The time that the battery test will be initiated in hh:mm format."
+ ::= { upsEBatteryTestScheduleEntry 3 }
+
+
+ upsEBatteryTestScheduleType OBJECT-TYPE
+ SYNTAX INTEGER { none ( 1 ) , batteryTest10sec ( 2 ) , batteryTestUntilLow ( 3 ) ,
+ batteryTestWithTime ( 4 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The type of battery test."
+ ::= { upsEBatteryTestScheduleEntry 5 }
+
+
+ upsEBatteryTestScheduleTestWithTime OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The battery time of setting time test in seconds."
+ ::= { upsEBatteryTestScheduleEntry 6 }
+
+
+ upsEBatteryTestScheduleSpecialDay OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 10 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The special day that the battery test will be initiated in dd/mm/yyyy format."
+ ::= { upsEBatteryTestScheduleEntry 7 }
+
+--========================================================================
+-- upsEControl
+--========================================================================
+
+ upsEControlOutputOffDelay OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Setting this value to other than zero will cause the UPS
+ output to turn off after the number of seconds. "
+ ::= { upsEControl 1 }
+
+ upsEControlOutputOnDelay OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Setting this value to other than zero will cause the
+ UPS output to turn on after the number of seconds. "
+ ::= { upsEControl 2 }
+
+ upsEControlOutputOnOffControl OBJECT-TYPE
+ SYNTAX INTEGER { upsEOutputOff ( 1 ) , upsEOutputOffCancel ( 2 ) , upsESleep( 3 ) , none ( 4 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "upsEOutputOff ( 1 ) indicates the shutdown sequence,
+ upsEOutputOffCancel ( 2 ) indicates cancel the shutdown sequence,
+ upsESleep( 3 ) indicates shutdown UPS first, then switch on."
+ ::= { upsEControl 3 }
+
+ upsEShutdownEventsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsShutdownEventsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "This table describes the parametes for shutdown process
+ when shutdown event occurs"
+ ::= { upsEControl 4 }
+
+ upsEShutdownEventsEntry OBJECT-TYPE
+ SYNTAX UpsShutdownEventsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular shutdown
+ event line"
+ INDEX { upsEShutdownEvent }
+ ::= { upsEShutdownEventsTable 1 }
+
+ UpsShutdownEventsEntry ::= SEQUENCE {
+ upsEShutdownEvent INTEGER,
+ upsEShutdownEventAction INTEGER,
+ upsEShutdownwarningPeriodTime NonNegativeInteger,
+ upsEShutdownWarningPeriodInterval NonNegativeInteger
+ }
+
+
+ upsEShutdownEvent OBJECT-TYPE
+ SYNTAX INTEGER { acFail ( 1 ) , batteryLow ( 2 ) , upsEOverLoad ( 3 ) ,
+ upsEOverTemperature ( 4 ) , upsEWeeklySchedule ( 5 ) ,
+ upsESpecialSchedule ( 6 ) , environmentTemperatureOverThreshold ( 7 ) ,
+ environmentHumidityOverThreshold ( 8 ) , environmentContact1Alarm ( 9 ) ,
+ environmentContact2Alarm ( 10 ), belowCapacityLimit( 11 ), belowRemainTimeLimit( 12 )}
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The shutdown event identification"
+ ::= { upsEShutdownEventsEntry 1 }
+
+
+ upsEShutdownEventAction OBJECT-TYPE
+ SYNTAX INTEGER { disable ( 1 ) , warning ( 2 ) , shutdownClient ( 3 ) , shutdownUPS ( 4 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Status of the corresponding shutdown Event.
+ When set to disable(), shutdown process will not start when
+ corresponding event occured."
+ ::= { upsEShutdownEventsEntry 2 }
+
+
+ upsEShutdownwarningPeriodTime OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The Delay in seconds after the occurance of the curresponding shutdown
+ event, and warning message should be popped in this period."
+ ::= { upsEShutdownEventsEntry 3 }
+
+
+ upsEShutdownWarningPeriodInterval OBJECT-TYPE
+ SYNTAX NonNegativeInteger
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The frequency of sending warning messages to the connected
+ clients when the curresponding shutdown event occurs.
+ The value is in units of seconds."
+ ::= { upsEShutdownEventsEntry 4 }
+
+ upsEControlWeeklyScheduleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsControlWeeklyScheduleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The table to schedule shutting down the ups by weekly"
+ ::= { upsEControl 5 }
+
+ upsEControlWeeklyScheduleEntry OBJECT-TYPE
+ SYNTAX UpsControlWeeklyScheduleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular line"
+ INDEX { upsEControlWeeklyScheduleIndex }
+ ::= { upsEControlWeeklyScheduleTable 1 }
+
+ UpsControlWeeklyScheduleEntry ::= SEQUENCE {
+ upsEControlWeeklyScheduleIndex PositiveInteger,
+ upsEWeeklyScheduleShutdownDay INTEGER,
+ upsEWeeklyScheduleShutdownTime DisplayString,
+ upsEWeeklyScheduleRestartDay INTEGER,
+ upsEWeeklyScheduleRestartTime DisplayString
+ }
+
+
+ upsEControlWeeklyScheduleIndex OBJECT-TYPE
+ SYNTAX PositiveInteger
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "the index of schedule events."
+ ::= { upsEControlWeeklyScheduleEntry 1 }
+
+
+ upsEWeeklyScheduleShutdownDay OBJECT-TYPE
+ SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednesday ( 3 ) ,
+ thursday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
+ sunday ( 7 ) , none ( 8 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "the weekday on which upsE shoud shutdown"
+ ::= { upsEControlWeeklyScheduleEntry 2 }
+
+
+ upsEWeeklyScheduleShutdownTime OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 5 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The time that the process of shutting down the UPS will be initiated
+ in hh:mm format."
+ ::= { upsEControlWeeklyScheduleEntry 3 }
+
+
+ upsEWeeklyScheduleRestartDay OBJECT-TYPE
+ SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednesday ( 3 ) ,
+ thursday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
+ sunday ( 7 ) , none ( 8 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "the weekday on which the UPS should restart."
+ ::= { upsEControlWeeklyScheduleEntry 4 }
+
+
+ upsEWeeklyScheduleRestartTime OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The time the UPS will restart in hh:mm format."
+ ::= { upsEControlWeeklyScheduleEntry 5 }
+
+ upsEControlSpecialDayScheduleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsControlSpecialDayScheduleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The table to schedule shutting down the ups."
+ ::= { upsEControl 6 }
+
+ upsEControlSpecialDayScheduleEntry OBJECT-TYPE
+ SYNTAX UpsControlSpecialDayScheduleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular line."
+ INDEX { upsEControlSpecialDayScheduleIndex }
+ ::= { upsEControlSpecialDayScheduleTable 1 }
+
+ UpsControlSpecialDayScheduleEntry ::= SEQUENCE {
+ upsEControlSpecialDayScheduleIndex PositiveInteger,
+ upsESpecialDayScheduleShutdownDay DisplayString,
+ upsESpecialDayScheduleShutdownTime DisplayString,
+ upsESpecialDayScheduleRestartDay DisplayString,
+ upsESpecialDayScheduleRestartTime DisplayString
+ }
+
+
+ upsEControlSpecialDayScheduleIndex OBJECT-TYPE
+ SYNTAX PositiveInteger
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The index of special day schedule."
+ ::= { upsEControlSpecialDayScheduleEntry 1 }
+
+
+ upsESpecialDayScheduleShutdownDay OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The special day on which UPS should shutdown with the format
+ of DD/MM/YYYY."
+ ::= { upsEControlSpecialDayScheduleEntry 2 }
+
+
+ upsESpecialDayScheduleShutdownTime OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The time that the process of shutting down the UPS will be initiated
+ in hh:mm format."
+ ::= { upsEControlSpecialDayScheduleEntry 3 }
+
+
+ upsESpecialDayScheduleRestartDay OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The special day on which the UPS should restart with the format
+ of DD/MM/YYYY."
+ ::= { upsEControlSpecialDayScheduleEntry 4 }
+
+
+ upsESpecialDayScheduleRestartTime OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The time the UPS will restart in hh:mm format."
+ ::= { upsEControlSpecialDayScheduleEntry 5 }
+
+ upsESystemMasterOffDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The UPS output will shutdown after the indicated number of seconds, -1 indicate no action."
+ ::= { upsEControl 7 }
+ upsESystemMasterOnDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "The UPS output will start on after the indicated number of seconds, -1 indicate no action."
+ ::= { upsEControl 8 }
+
+--========================================================================
+-- upsETrapControl
+--========================================================================
+
+ upsETrapsReceiversTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsTrapsReceiversEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION " This table list the managers'IP to send traps to."
+ ::= { upsETrapControl 1 }
+
+ upsETrapsReceiversEntry OBJECT-TYPE
+ SYNTAX UpsTrapsReceiversEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "An entry containing information applicable to a particular input line."
+ INDEX { upsETrapsReceiversIndex }
+ ::= { upsETrapsReceiversTable 1 }
+
+ UpsTrapsReceiversEntry ::= SEQUENCE {
+ upsETrapsReceiversIndex PositiveInteger,
+ upsETrapsReceiverAddress DisplayString,
+ upsETrapReceiverCommunityString DisplayString,
+ upsETrapType INTEGER,
+ upsETrapsSeverityLevel INTEGER,
+ upsETrapReceiverDescription DisplayString
+ }
+
+ upsETrapsReceiversIndex OBJECT-TYPE
+ SYNTAX PositiveInteger
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION "The index to a trap receiver entry"
+ ::= { upsETrapsReceiversEntry 1 }
+
+ upsETrapsReceiverAddress OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 45 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The IP address of the manager to send a trap to."
+ ::= { upsETrapsReceiversEntry 2 }
+
+ upsETrapReceiverCommunityString OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The community name to use in the trap when
+ sent to the manager."
+ ::= { upsETrapsReceiversEntry 3 }
+
+ upsETrapType OBJECT-TYPE
+ SYNTAX INTEGER { none ( 1 ) , rfc1628Trap ( 2 ) , eppcTrap ( 3 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The type of trap to be received by the manager."
+ ::= { upsETrapsReceiversEntry 4 }
+
+ upsETrapsSeverityLevel OBJECT-TYPE
+ SYNTAX INTEGER { informational ( 1 ) , warning ( 2 ) , severe ( 3 ) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "The severity level of traps to be received by this manager."
+ ::= { upsETrapsReceiversEntry 5 }
+
+ upsETrapReceiverDescription OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Description of trap receivers"
+ ::= { upsETrapsReceiversEntry 6 }
+
+ upsETrapState OBJECT-TYPE
+ SYNTAX DisplayString ( SIZE ( 0 .. 127 ) )
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "the values indicate the unrestored traps.
+ For example, after AC fail, the agent send
+ the trap 1(AC Fail) and trap 7(battery on) to
+ NMS. so the value of upsETrapState should be '1,7'.
+ And then the AC restore, the value of upsETrapState
+ should change to empty."
+ ::= { upsETrapControl 2 }
+
+-- ===========================================================================
+-- Trap defination
+-- ===========================================================================
+
+upsEPowerFail TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Utility power not available."
+ ::= 1
+
+upsEPowerRestored TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Utility power has restored."
+ ::= 2
+
+upsELowBattery TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "SEVERE: The UPS batteries are low and will soon be exhausted."
+ ::= 3
+
+upsEReturnFromLowBattery TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS has return from a low battery condition."
+ ::= 4
+
+upsEFailed TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "SEVERE: The UPS is not working fine."
+ ::= 5
+
+upsEOk TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS is working fine."
+ ::= 6
+
+upsEOnBattery TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEBatteryEstimatedMinutesRemaining,
+ upsESecondsOnBattery
+ }
+ DESCRIPTION
+ "WARNING: The UPS has switched to battery backup power."
+ ::= 7
+
+upsENotOnBattery TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS is not on battery power."
+ ::= 8
+
+upsETestInProgress TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The testing is going on ups."
+ ::= 9
+
+upsETestOver TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEBatteryTestStart,
+ upsEBatteryTestSettingTime,
+ upsEBatteryTestResult,
+ upsEBatteryTestStartTime
+ }
+ DESCRIPTION
+ "INFORMATION: The testing of UPS is completed."
+ ::= 10
+
+upsEBypassOn TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS has enabled bypass."
+ ::= 11
+
+upsEOnline TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS is not on Bypass and return to normal status."
+ ::= 12
+
+upsECommunicationLost TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "SEVERE: Communication to the UPS has been lost."
+ ::= 13
+
+upsECommunicationEstablished TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Communication with the UPS has been established."
+ ::= 14
+
+upsEGoingShutdown TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: The UPS is going to shutdown output."
+ ::= 15
+
+upsEShutdownCancelled TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS is not going to shutdown output."
+ ::= 16
+
+upsEOutlet1GoingShutdown TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: The UPS is going to shutdown outlet1."
+ ::= 17
+
+upsEOutlet1ShutdownCancelled TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS is not going to shutdown outlet1."
+ ::= 18
+
+upsEOutlet2GoingShutdown TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: The UPS is going to shutdown outlet2."
+ ::= 19
+
+upsEOutlet2ShutdownCancelled TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS is not going to shutdown outlet2."
+ ::= 20
+
+upsESleeping TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEControlOutputOnDelay
+ }
+ DESCRIPTION
+ "INFORMATION: UPS has entered sleep mode and power to load has been cut off."
+ ::= 21
+
+upsEWokeUp TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS woke up from sleep mode and power to load has been restored."
+ ::= 22
+
+upsEOverTemperature TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsESystemTemperature,
+ upsESystemConfigOverTemperatureSetPoint
+ }
+ DESCRIPTION
+ "WARNING: The UPS temperature is over the setting limit."
+ ::= 23
+
+upsENotOverTemperature TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsESystemTemperature,
+ upsESystemConfigOverTemperatureSetPoint
+ }
+ DESCRIPTION
+ "INFORMATION: The UPS temperature is not over the setting limit."
+ ::= 24
+
+upsEOverLoad TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsESystemOutputLoad,
+ upsESystemConfigOutputLoadHighSetPoint
+ }
+ DESCRIPTION
+ "WARNING: The UPS load is over the setting limit."
+ ::= 25
+
+upsENotOverLoad TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsESystemOutputLoad,
+ upsESystemConfigOutputLoadHighSetPoint
+ }
+ DESCRIPTION
+ "INFORMATION: The UPS load is not over the setting limit."
+ ::= 26
+
+upsEModuleInserted TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: UPS module or charger module plug-in."
+ ::= 27
+
+upsEModuleRemoved TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: UPS module or charger module unplugs."
+ ::= 28
+
+sensorTemperatureTooHigh TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentTemperatureHighSetPoint,
+ upsEEnvironmentCurrentTemperature
+ }
+ DESCRIPTION
+ "WARNING: Sensor Temperature over high Set point."
+ ::= 29
+
+sensorTemperatureNotHigh TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentTemperatureHighSetPoint,
+ upsEEnvironmentCurrentTemperature
+ }
+ DESCRIPTION
+ "INFORMATION: Sensor Temperature not over high Set point."
+ ::= 30
+
+sensorTemperatureTooLow TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentTemperatureLowSetPoint,
+ upsEEnvironmentCurrentTemperature
+ }
+ DESCRIPTION
+ "WARNING: Sensor Temperature under low Set point."
+ ::= 31
+
+sensorTemperatureNotLow TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentTemperatureLowSetPoint,
+ upsEEnvironmentCurrentTemperature
+ }
+ DESCRIPTION
+ "INFORMATION: Sensor Temperature not under low Set point."
+ ::= 32
+
+sensorHumidityTooHigh TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentHumidityHighSetPoint,
+ upsEEnvironmentCurrentHumidity
+ }
+ DESCRIPTION
+ "WARNING: Sensor Humidity over high Set point."
+ ::= 33
+
+sensorHumidityNotHigh TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentHumidityHighSetPoint,
+ upsEEnvironmentCurrentHumidity
+ }
+ DESCRIPTION
+ "INFORMATION: Sensor Humidity not over high Set point."
+ ::= 34
+
+sensorHumidityTooLow TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentHumidityLowSetPoint,
+ upsEEnvironmentCurrentHumidity
+ }
+ DESCRIPTION
+ "WARNING: Sensor Humidity under low Set point."
+ ::= 35
+
+sensorHumidityNotLow TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentHumidityLowSetPoint,
+ upsEEnvironmentCurrentHumidity
+ }
+ DESCRIPTION
+ "INFORMATION: Sensor Humidity not under low Set point."
+ ::= 36
+
+contactAlarm1Active TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentContactType,
+ upsEEnvironmentContactDescription
+ }
+ DESCRIPTION
+ "WARNING: Contact Alarm-1 activated."
+ ::= 37
+
+concactAlarm1Normal TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentContactType,
+ upsEEnvironmentContactDescription
+ }
+ DESCRIPTION
+ "INFORMATION: Contact Alarm-1 not active."
+ ::= 38
+
+contactAlarm2Active TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentContactType,
+ upsEEnvironmentContactDescription
+ }
+ DESCRIPTION
+ "WARNING: Contact Alarm-2 activated."
+ ::= 39
+
+contactAlarm2Normal TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEEnvironmentContactType,
+ upsEEnvironmentContactDescription
+ }
+ DESCRIPTION
+ "INFORMATION: Contact Alarm-2 not active."
+ ::= 40
+
+upsEInternalwarning TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Internal warning."
+ ::= 41
+
+upsEReturnFromInternalwarning TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Internal warning."
+ ::= 42
+
+upsEEPOActive TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: EPO Active."
+ ::= 43
+
+upsEReturnFromEPOActive TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from EPO Active."
+ ::= 44
+
+upsEModuleUnlock TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Module Unlock."
+ ::= 45
+
+upsEReturnFromModuleUnlock TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Module Unlock."
+ ::= 46
+
+upsEMain1Neutralloss TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Main 1 Neutral loss."
+ ::= 47
+
+upsEReturnFromMain1Neutralloss TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Main 1 Neutral loss."
+ ::= 48
+
+upsEMain1phaseerror TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Main 1 phase error."
+ ::= 49
+
+upsEReturnFromMain1phaseerror TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Main 1 phase error."
+ ::= 50
+
+upsESitefault TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Site fault."
+ ::= 51
+
+upsEReturnFromSitefault TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Site fault."
+ ::= 52
+
+upsEBypassAbnormal TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Bypass Abnormal."
+ ::= 53
+
+upsEReturnFromBypassAbnormal TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Bypass Abnormal."
+ ::= 54
+
+upsEBypassPhaseError TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Bypass Phase Error."
+ ::= 55
+
+upsEReturnFromBypassPhaseError TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Bypass Phase Error."
+ ::= 56
+
+upsEBatteryOpen TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Battery Open."
+ ::= 57
+
+upsEReturnFromBatteryOpen TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Battery Open."
+ ::= 58
+
+upsEBatteryOverCharge TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Battery Over Charge."
+ ::= 59
+
+upsEReturnFromBatteryOverCharge TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Battery Over Charge."
+ ::= 60
+
+upsEBatteryReverse TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Battery Reverse."
+ ::= 61
+
+upsEReturnFromBatteryReverse TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Battery Reverse."
+ ::= 62
+
+upsEOverloadforewarning TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Overload forewarning."
+ ::= 63
+
+upsEReturnFromOverloadforewarning TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Overload forewarning."
+ ::= 64
+
+upsEOverloadWarning TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Overload Warning."
+ ::= 65
+
+upsEReturnFromOverloadWarning TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Overload Warning."
+ ::= 66
+
+upsEFanLock TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Fan Lock."
+ ::= 67
+
+upsEReturnFromFanLock TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Fan Lock."
+ ::= 68
+
+upsEMaintaincoverisopen TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Maintain cover is open."
+ ::= 69
+
+upsEReturnFromMaintaincoverisopen TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Maintain cover is open."
+ ::= 70
+
+upsEChargerfault TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Charger fault."
+ ::= 71
+
+upsEReturnFromChargerfault TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Charger fault."
+ ::= 72
+
+upsEModulelocationerror TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Module location error."
+ ::= 73
+
+upsEReturnFromModulelocationerror TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Module location error."
+ ::= 74
+
+upsETurnonabnormal TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Turn on abnormal."
+ ::= 75
+
+upsEReturnFromTurnonabnormal TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Turn on abnormal."
+ ::= 76
+
+upsERedundancyloss TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Redundancy loss."
+ ::= 77
+
+upsEReturnFromRedundancyloss TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Redundancy loss."
+ ::= 78
+
+upsEHotSwapActived TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Hot Swap Active."
+ ::= 79
+
+upsEReturnFromHotSwapActived TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Hot Swap Active."
+ ::= 80
+
+upsEBatteryInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Battery Inform."
+ ::= 81
+
+upsEReturnFromBatteryInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Battery Inform."
+ ::= 82
+
+upsEInspectionInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Inspection Inform."
+ ::= 83
+
+upsEReturnFromInspectionInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Inspection Inform."
+ ::= 84
+
+upsEGuaranteeInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Guarantee Inform."
+ ::= 85
+
+upsEReturnFromGuaranteeInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Guarantee Inform."
+ ::= 86
+
+upsETemperatureLow TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Temperature Low."
+ ::= 87
+
+upsEReturnFromTemperatureLow TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Temperature Low."
+ ::= 88
+
+upsETemperatureHigh TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Temperature High."
+ ::= 89
+
+upsEReturnFromTemperatureHigh TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Temperature High."
+ ::= 90
+
+upsEBatteryOverTemperature TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Battery Over Temperature."
+ ::= 91
+
+upsEReturnFromBatteryOverTemperature TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Battery Over Temperature."
+ ::= 92
+
+upsEFanMaintainInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Fan Maintain Inform."
+ ::= 93
+
+upsEReturnFromFanMaintainInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Fan Maintain Inform."
+ ::= 94
+
+upsEBusCapacitanceMaintainInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Bus Capacitance Maintain Inform."
+ ::= 95
+
+upsEReturnFromBusCapacitanceMaintainInform TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from Bus Capacitance Maintain Inform."
+ ::= 96
+
+upsESystemOverCapacity TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: System Over Capacity."
+ ::= 97
+
+upsEReturnFromSystemOverCapacity TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Return from System Over Capacity."
+ ::= 98
+
+-- Trap Id 99-122 is not defined.
+
+upsEBelowCapacityLimit TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEBatteryEstimatedChargeRemaining,
+ upsESystemConfigBelowCapacityLimit
+ }
+ DESCRIPTION
+ "SEVERE: The UPS batteries capacity is lower than setting limit."
+ ::= 123
+
+upsENotBelowCapacityLimit TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS batteries capacity is not lower than setting limit."
+ ::= 124
+
+upsEBelowRemainTimeLimit TRAP-TYPE
+ ENTERPRISE upsETraps
+ VARIABLES {
+ upsEBatteryEstimatedMinutesRemaining,
+ upsESystemConfigBelowRemainTimeLimit
+ }
+ DESCRIPTION
+ "SEVERE: The UPS batteries backup time is below the setting limit."
+ ::= 125
+
+upsENotBelowRemainTimeLimit TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: The UPS batteries backup time is not below the setting limit."
+ ::= 126
+
+upsELoadSegment1Off TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Load segment 1 is off."
+ ::= 127
+upsELoadSegment1On TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Load segment 1 is on."
+ ::= 128
+
+upsELoadSegment2Off TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "WARNING: Load segment 2 is off."
+ ::= 129
+upsELoadSegment2On TRAP-TYPE
+ ENTERPRISE upsETraps
+ DESCRIPTION
+ "INFORMATION: Load segment 2 is on."
+ ::= 130
+
+END
+