summaryrefslogtreecommitdiff
path: root/MIBS/ray/RAY-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/ray/RAY-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/ray/RAY-MIB')
-rw-r--r--MIBS/ray/RAY-MIB1148
1 files changed, 1148 insertions, 0 deletions
diff --git a/MIBS/ray/RAY-MIB b/MIBS/ray/RAY-MIB
new file mode 100644
index 0000000..e52feea
--- /dev/null
+++ b/MIBS/ray/RAY-MIB
@@ -0,0 +1,1148 @@
+RAY-MIB DEFINITIONS ::= BEGIN
+ IMPORTS
+ enterprises, IpAddress, Gauge
+ FROM RFC1155-SMI
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
+ Unsigned32, TimeTicks, Counter32, Gauge32, Integer32, Counter64
+ FROM SNMPv2-SMI
+ DateAndTime, TEXTUAL-CONVENTION
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ mib-2 FROM SNMPv2-SMI
+ snmpTraps
+ FROM SNMPv2-MIB;
+
+ray MODULE-IDENTITY
+ LAST-UPDATED "201610040000Z"
+ ORGANIZATION "Racom s.r.o"
+ CONTACT-INFO
+ "Racom s.r.o
+ Mirova 1283
+ 592 31 Nove Mesto na Morave
+ Czech Republic
+ Tel: +420 565 659 511
+ Fax: +420 565 659 512
+ E-mail: racom@racom.eu"
+ DESCRIPTION "The MIB module defines management objects for RAy product series. Revision 201610040000Z."
+ REVISION "201610040000Z"
+ DESCRIPTION "Latest version of this MIB module"
+ ::= { racom 1 }
+
+DisplayString ::= OCTET STRING
+
+PhysAddress ::= OCTET STRING
+
+ServiceState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION "System service or device state."
+ SYNTAX INTEGER {
+ na (0), -- service/device state not available
+ up (1), -- service is running or device is up
+ down (2) -- service is not running or device is down
+ }
+
+AlarmState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION "Alarm status."
+ SYNTAX INTEGER {
+ na (0), -- alarm state not available
+ up (1), -- alarm up
+ down (2), -- alarm down
+ ack (3) -- alarm up and acknowledged
+ }
+
+OptionSetting ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION "Setting of some options."
+ SYNTAX INTEGER {
+ na (0),
+ on (1),
+ off (2)
+ }
+
+ModulationList ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION "Radio channel modulations numerical list"
+ SYNTAX INTEGER {
+ na (0),
+ qpsk (1),
+ qam16 (2),
+ qam32 (3),
+ qam64 (4),
+ qam128 (5),
+ qam256 (6)
+ }
+
+
+racom OBJECT IDENTIFIER ::= { enterprises 33555 }
+
+station OBJECT IDENTIFIER ::= {ray 1}
+interface OBJECT IDENTIFIER ::= {ray 2}
+statistic OBJECT IDENTIFIER ::= {ray 3}
+rayTraps OBJECT IDENTIFIER ::= {ray 10}
+ray2Traps OBJECT IDENTIFIER ::= {ray 11}
+
+-- station MIB
+
+product OBJECT IDENTIFIER ::= {station 1}
+info OBJECT IDENTIFIER ::= {station 2}
+status OBJECT IDENTIFIER ::= {station 3}
+chassis OBJECT IDENTIFIER ::= {station 4}
+system OBJECT IDENTIFIER ::= {station 5}
+access OBJECT IDENTIFIER ::= {station 6}
+authorization OBJECT IDENTIFIER ::= {station 7}
+alarm OBJECT IDENTIFIER ::= {station 8}
+
+-- product MIB
+
+productName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Product name."
+ ::= { product 1 }
+
+serialNumber OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Product serial number."
+ ::= { product 2 }
+
+unitType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..4))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Station type (L or H) and number of the Ethernet ports (1 or 2)."
+ ::= { product 3 }
+
+-- info MIB
+
+deviceName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Station name."
+ ::= { info 1 }
+
+swVer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Firmware version."
+ ::= { info 2 }
+
+swVerRadio OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio firmware version."
+ ::= { info 3 }
+
+-- status mib
+systemStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ ok (1),
+ warning (2),
+ alarm (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Unit status."
+ ::= { status 1 }
+
+lineStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ ok (1),
+ analyzer (2),
+ connecting (3),
+ searching (4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio link status. Supported by RAy10 only."
+ ::= { status 2 }
+
+peerNumber OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Peer station serial number."
+ ::= { status 3 }
+
+rfPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ ok (1),
+ fail (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "RF Power amplifier OK/Failure."
+ ::= { status 4 }
+
+searchModeDisabled OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Search mode disabled on/off. Supported by RAy10 only."
+ ::= { status 5 }
+
+ethPeer OBJECT-TYPE
+ SYNTAX ServiceState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Peer station user Ethernet link status. Not supported by RAy2."
+ ::= { status 6 }
+
+securePeerMode OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Secure peer mode. Not supported by RAy10."
+ ::= { status 7 }
+
+lineStatusII OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ setup (1),
+ single (2),
+ connecting (3),
+ authorizing (4),
+ ok (5),
+ analyzer (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio link status. Not supported by RAy10."
+ ::= { status 8 }
+
+eth1Link OBJECT-TYPE
+ SYNTAX ServiceState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet 1 link status. Supported by RAy2 only."
+ ::= { status 9 }
+
+eth2Link OBJECT-TYPE
+ SYNTAX ServiceState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet 2 link status. Supported by RAy2 only."
+ ::= { status 10 }
+
+
+-- chassis mib
+temperatureModem OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem temperature in hundredths of Celsius (C)."
+ ::= { chassis 1 }
+
+temperatureRadio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio temperature in hundredths of Celsius (C)."
+ ::= { chassis 2}
+
+voltageUnit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Power supply voltage in tenths of Volts (V)."
+ ::= { chassis 3 }
+
+voltageSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ aux (1),
+ poe (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Source of supply voltage. Supported by RAy2 only."
+ ::= { chassis 4 }
+
+
+-- system mib
+useCpu OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System use CPU in %."
+ ::= { system 1 }
+
+useMemory OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System use memory in %."
+ ::= { system 2 }
+
+useLogStorage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Use storage for log in %."
+ ::= { system 3 }
+
+-- access mib
+sshd OBJECT-TYPE
+ SYNTAX INTEGER {
+ on (1),
+ onlykey (2),
+ off (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Management interface: SSH."
+ ::= { access 1 }
+
+telnetd OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Management interface: Telnet."
+ ::= { access 2 }
+
+httpd OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Management interface: HTTP."
+ ::= { access 3 }
+
+ip OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Management interface: IP address."
+ ::= { access 4 }
+
+mac OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Management interface: MAC address."
+ ::= { access 5 }
+
+managementVlan OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Management interface: VLAN on/off."
+ ::= { access 6 }
+
+managementVlanId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Management interface: VLAN ID."
+ ::= { access 7 }
+
+wifiHAP OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Management interface: WiFi Host Access Point."
+ ::= { access 8 }
+
+
+-- authorization mib
+keyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF KeyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "List of product key entries. Supported by RAy10 only."
+ ::= { authorization 1 }
+
+keyEntry OBJECT-TYPE
+ SYNTAX KeyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Product key entry. Supported by RAy10 only."
+ INDEX { keyName }
+ ::= { keyTable 1 }
+
+KeyEntry ::=
+ SEQUENCE {
+ keyName DisplayString
+ }
+
+keyName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(1..64))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Product key name. Supported by RAy10 only."
+ ::= { keyEntry 1 }
+
+-- alarm mib
+alarmTemperature OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Temperature alarm state. Supported by RAy2 only."
+ ::= { alarm 1 }
+
+alarmVoltageLow OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Low voltage alarm state. Supported by RAy2 only."
+ ::= { alarm 2 }
+
+alarmVoltageHigh OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "High voltage alarm state. Supported by RAy2 only."
+ ::= { alarm 3 }
+
+alarmRss OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "RSS alarm state. Supported by RAy2 only."
+ ::= { alarm 4 }
+
+alarmSnr OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SNR alarm state. Supported by RAy2 only."
+ ::= { alarm 5 }
+
+alarmBer OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "BER alarm state. Supported by RAy2 only."
+ ::= { alarm 6 }
+
+alarmPeerDisconnected OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Peer disconnect alarm state. Supported by RAy2 only."
+ ::= { alarm 7 }
+
+alarmEth1Down OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet 1 Link Down alarm state. Supported by RAy2 only."
+ ::= { alarm 8 }
+
+alarmEth2Down OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet 2 Link Down alarm state. Supported by RAy2 only."
+ ::= { alarm 9 }
+
+alarmRfPowerFail OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "RF Power Fail alarm state. Supported by RAy2 only."
+ ::= { alarm 10 }
+
+alarmNetBitrate OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Air Speed below Limit alarm state. Supported by RAy2 only."
+ ::= { alarm 11 }
+
+alarmWifiOn OBJECT-TYPE
+ SYNTAX AlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "WiFi Host Access Oint on. Supported by RAy2 only."
+ ::= { alarm 12 }
+
+
+-- interface mib
+ifRadio OBJECT IDENTIFIER ::= {interface 1}
+ifEth OBJECT IDENTIFIER ::= {interface 2}
+
+-- radio mib
+rxChannel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Receiver channel ID."
+ ::= { ifRadio 1 }
+
+txChannel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Transceiver channel ID."
+ ::= { ifRadio 2 }
+
+rxFreq OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Receiver frequency in kHz."
+ ::= { ifRadio 3 }
+
+txFreq OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Transceiver frequency in kHz."
+ ::= { ifRadio 4 }
+
+rxModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Rx modulation text ID."
+ ::= { ifRadio 5 }
+
+txModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Tx modulation text ID."
+ ::= { ifRadio 6 }
+
+rxModulationIndex OBJECT-TYPE
+ SYNTAX ModulationList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Rx modulation index."
+ ::= { ifRadio 7 }
+
+txModulationIndex OBJECT-TYPE
+ SYNTAX ModulationList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Tx modulation index."
+ ::= { ifRadio 8 }
+
+bandwidth OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ bw-28MHz (1),
+ bw-14MHz (2),
+ bw-7MHz (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio channel bandwidth. Supported by RAy10 only."
+ ::= { ifRadio 9 }
+
+coding OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ low (1),
+ hi (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Channel coding level. Supported by RAy10 only."
+ ::= { ifRadio 10 }
+
+matching OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Channel matching."
+ ::= { ifRadio 11 }
+
+rfPowerConfigured OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Configured RF Power in dBm."
+ ::= { ifRadio 12 }
+
+netBitrate OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current net bitrate in kbps."
+ ::= { ifRadio 13 }
+
+maxNetBitrate OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Maximum net bitrate in Mbps."
+ ::= { ifRadio 14 }
+
+bandwidthKHz OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio channel bandwidth in kHz. Not supported by RAy10."
+ ::= { ifRadio 15 }
+
+channelArrangement OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ accp (1),
+ acap (2),
+ ccdp (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Channel arrangement. Not supported by RAy10."
+ ::= { ifRadio 16 }
+
+rfPowerCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current RF Power in dBm. Not supported by RAy10."
+ ::= { ifRadio 17 }
+
+-- ifEth mib
+
+ifEthTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfEthEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "List of Ethernet interfaces."
+ ::= { ifEth 1 }
+
+ifEthEntry OBJECT-TYPE
+ SYNTAX IfEthEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Ethernet interface entry."
+ INDEX { speed }
+ ::= { ifEthTable 1 }
+
+IfEthEntry ::=
+ SEQUENCE {
+ speed Integer32,
+ duplex INTEGER,
+ mdix INTEGER,
+ autonego OptionSetting,
+ pause OptionSetting,
+ asymPause OptionSetting
+ }
+
+speed OBJECT-TYPE
+ SYNTAX Integer32(1..1000000000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet speed."
+ ::= { ifEthEntry 1 }
+duplex OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ full (1),
+ half (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet duplex."
+ ::= { ifEthEntry 2 }
+
+mdix OBJECT-TYPE
+ SYNTAX INTEGER {
+ na (0),
+ mdi (1),
+ mdi-x (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet MDI-X / MDI."
+ ::= { ifEthEntry 3 }
+
+autonego OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet autonego."
+ ::= { ifEthEntry 4 }
+
+pause OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet pause."
+ ::= { ifEthEntry 5 }
+
+asymPause OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet asymmetric pause."
+ ::= { ifEthEntry 6 }
+
+prioritized OBJECT-TYPE
+ SYNTAX OptionSetting
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet prioritized VLAN support. Supported by RAy10 only."
+ ::= { ifEth 2 }
+
+vlanId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet prioritized VLAN ID. Supported by RAy10 only."
+ ::= { ifEth 3 }
+
+serviceVlanId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ethernet service VLAN ID between local and remote station. Not supported by RAy2."
+ ::= { ifEth 4 }
+
+
+-- statistic mib
+modemR OBJECT IDENTIFIER ::= {statistic 1}
+radio OBJECT IDENTIFIER ::= {statistic 2}
+ethernet OBJECT IDENTIFIER ::= {statistic 3}
+
+ -- statistic radiomodem ethernet mib
+rxPauseFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of received Control frames with a valid PAUSE op-code. Supported by RAy10 only."
+ ::= { modemR 1 }
+
+rxControlFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of received Control frames. Supported by RAy10 only."
+ ::= { modemR 2 }
+
+rxBroadcast OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of received packets with a broadcast destination address. Supported by RAy10 only."
+ ::= { modemR 3 }
+
+rxMulticast OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of received packets with a multicast destination address. Supported by RAy10 only."
+ ::= { modemR 4 }
+
+rxDones OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of successfully received packets. Supported by RAy10 only."
+ ::= { modemR 5 }
+
+rxOutOfRangeErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of received frames larger than 1518 bytes (the frame Type/Length field is indicating a value larger than 1518 bytes). Supported by RAy10 only."
+ ::= { modemR 6 }
+
+rxCrcErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of received frames with the CRC which does not match the internally generated CRC. Supported by RAy10 only."
+ ::= { modemR 7 }
+
+rxCodeErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of received packets with one or more erroneous nibbles. Supported by RAy10 only."
+ ::= { modemR 8 }
+
+rxFalseCarrierErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Rx false carrier errors. Supported by RAy10 only."
+ ::= { modemR 9 }
+
+rxDroppedPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of dropped packets. Supported by RAy10 only."
+ ::= { modemR 10 }
+
+rxHCBytes OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of received bytes. Supported by RAy10 only."
+ ::= { modemR 11 }
+
+txPauseFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of transmitted Control frames with a valid PAUSE op-code. Supported by RAy10 only."
+ ::= { modemR 12 }
+
+txControlFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of transmitted Control frames. Supported by RAy10 only."
+ ::= { modemR 13 }
+
+txBroadcast OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of transmitted packets with a broadcast destination address. Supported by RAy10 only."
+ ::= { modemR 14 }
+
+txMulticast OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of transmitted packets with a multicast destination address. Supported by RAy10 only."
+ ::= { modemR 15 }
+
+txDones OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of successfully transmitted packets. Supported by RAy10 only."
+ ::= { modemR 16 }
+
+txLengthCheckErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of transmitted packets with the frame Length field (not a Type field) value that does not match the actual data byte length. Supported by RAy10 only."
+ ::= { modemR 17 }
+
+txCrcErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of transmitted frames with the CRC which does not match the internally generated CRC. Supported by RAy10 only."
+ ::= { modemR 18 }
+
+txCollisions OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Tx collisions. Supported by RAy10 only."
+ ::= { modemR 19 }
+
+txHCBytes OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of transmitted bytes. Supported by RAy10 only."
+ ::= { modemR 20 }
+
+-- statistic radio mib
+
+rss OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Receiving RSS indicator in decimal dBm (-39 -> -3,9)."
+ ::= { radio 1 }
+
+snr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Receiving SNR indicator in decimal dB (39 -> 3,9)."
+ ::= { radio 2 }
+
+fecBlockCounter OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Total block counter for BER calculation. Block size is 2048 bits. Supported by RAy10 only."
+ ::= { radio 3 }
+
+fecUncorrectBlockCounter OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Incorrect block counter for BER calculation. Block size is 2048 bits. Supported by RAy10 only."
+ ::= { radio 4 }
+
+timeAllConnect OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Overall link uptime."
+ ::= { radio 5 }
+
+timeAllDisconnect OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Overall link downtime."
+ ::= { radio 6 }
+
+timeMaxDisconnect OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The longest drop (disconnecting)."
+ ::= { radio 7 }
+
+numDisconnect OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Number of drops (disconnecting)."
+ ::= { radio 8 }
+
+reliability OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Reliability in thousandths of %."
+ ::= { radio 9 }
+
+linkUptime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current radio link uptime. Not supported by RAy10."
+ ::= { radio 10 }
+
+ber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Bit Error Rate (BER) multiplied by 10^9. Not supported by RAy10."
+ ::= { radio 11 }
+
+-- statistic Ethernet mib
+
+ethInThroughput OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Input Ethernet 1 data port throughput in kbps. Not supported by RAy10."
+ ::= { ethernet 1 }
+
+ethOutThroughput OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Output Ethernet 1 data port throughput in kbps. Not supported by RAy10."
+ ::= { ethernet 2 }
+
+eth2InThroughput OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Input Ethernet 2 data port throughput in kbps. Supported by RAy2 only."
+ ::= { ethernet 3 }
+
+eth2OutThroughput OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Output Ethernet 2 data port throughput in kbps. Supported by RAy2 only."
+ ::= { ethernet 4 }
+
+
+-- definition traps
+
+airDisconnect NOTIFICATION-TYPE
+ OBJECTS { lineStatus }
+ STATUS current
+ DESCRIPTION
+ "Air line disconnected. Not supported by RAy2."
+ ::= { rayTraps 1 }
+
+airConnect NOTIFICATION-TYPE
+ OBJECTS { lineStatus }
+ STATUS current
+ DESCRIPTION
+ "Air line connected after being disconnected. Not supported by RAy2."
+ ::= { rayTraps 2 }
+
+airWdog NOTIFICATION-TYPE
+ OBJECTS { lineStatus }
+ STATUS current
+ DESCRIPTION
+ "Air watch dog. Supported by RAy10 only."
+ ::= { rayTraps 3 }
+
+tempAlarm NOTIFICATION-TYPE
+ OBJECTS { temperatureModem }
+ STATUS current
+ DESCRIPTION
+ "Temperature exceeded the threshold. Not supported by RAy2."
+ ::= { rayTraps 4 }
+
+powerAlarm NOTIFICATION-TYPE
+ OBJECTS { voltageUnit }
+ STATUS current
+ DESCRIPTION
+ "Power voltage is out of the thresholds. Not supported by RAy2."
+ ::= { rayTraps 5 }
+
+memoryAlarm NOTIFICATION-TYPE
+ OBJECTS { useMemory }
+ STATUS current
+ DESCRIPTION
+ "Memory use exceeded the threshold. Supported by RAy10 only."
+ ::= { rayTraps 6 }
+
+rssAlarm NOTIFICATION-TYPE
+ OBJECTS { rss }
+ STATUS current
+ DESCRIPTION
+ "RSS exceeded the threshold. Not supported by RAy2."
+ ::= { rayTraps 7 }
+
+snrAlarm NOTIFICATION-TYPE
+ OBJECTS { snr }
+ STATUS current
+ DESCRIPTION
+ "SNR exceeded the threshold. Not supported by RAy2."
+ ::= { rayTraps 8 }
+
+berAlarm NOTIFICATION-TYPE
+ OBJECTS { fecUncorrectBlockCounter, fecBlockCounter }
+ STATUS current
+ DESCRIPTION
+ "BER exceeded the threshold. Not supported by RAy2."
+ ::= { rayTraps 9 }
+
+rfPowerFail NOTIFICATION-TYPE
+ OBJECTS { rfPowerStatus }
+ STATUS current
+ DESCRIPTION
+ "RF Power amplifier failure. Not supported."
+ ::= { rayTraps 10 }
+
+peerEthLinkDown NOTIFICATION-TYPE
+ OBJECTS { ethPeer }
+ STATUS current
+ DESCRIPTION
+ "Peer station Ethernet link Up/Down. Not supported by RAy2."
+ ::= { rayTraps 11 }
+
+
+-- RAy2 trap definitions
+
+tr2TemperatureAlarm NOTIFICATION-TYPE
+ OBJECTS { temperatureModem,
+ alarmTemperature }
+ STATUS current
+ DESCRIPTION
+ "Temperature exceeded the threshold. Supported by RAy2 only."
+ ::= { ray2Traps 1 }
+
+tr2VoltageLowAlarm NOTIFICATION-TYPE
+ OBJECTS { voltageUnit,
+ alarmVoltageLow }
+ STATUS current
+ DESCRIPTION
+ "Supply voltage below minimal threshold. Supported by RAy2 only."
+ ::= { ray2Traps 2 }
+
+tr2VoltageHighAlarm NOTIFICATION-TYPE
+ OBJECTS { voltageUnit,
+ alarmVoltageHigh }
+ STATUS current
+ DESCRIPTION
+ "Supply voltage above maximal threshold. Supported by RAy2 only."
+ ::= { ray2Traps 3 }
+
+tr2RssAlarm NOTIFICATION-TYPE
+ OBJECTS { rss,
+ alarmRss }
+ STATUS current
+ DESCRIPTION
+ "RSS exceeded the threshold. Supported by RAy2 only."
+ ::= { ray2Traps 4 }
+
+tr2SnrAlarm NOTIFICATION-TYPE
+ OBJECTS { snr,
+ alarmSnr }
+ STATUS current
+ DESCRIPTION
+ "SNR exceeded the threshold. Supported by RAy2 only."
+ ::= { ray2Traps 5 }
+
+tr2BerAlarm NOTIFICATION-TYPE
+ OBJECTS { ber,
+ alarmBer }
+ STATUS current
+ DESCRIPTION
+ "BER exceeded the threshold. Supported by RAy2 only."
+ ::= { ray2Traps 6 }
+
+tr2AirDisconnect NOTIFICATION-TYPE
+ OBJECTS { lineStatusII,
+ alarmPeerDisconnected }
+ STATUS current
+ DESCRIPTION
+ "Air line disconnected. Supported by RAy2 only."
+ ::= { ray2Traps 7 }
+
+tr2AirConnect NOTIFICATION-TYPE
+ OBJECTS { lineStatusII,
+ alarmPeerDisconnected }
+ STATUS current
+ DESCRIPTION
+ "Air line connected after being disconnected. Supported by RAy2 (up to fw 2.1.7.0) only."
+ ::= { ray2Traps 8 }
+
+tr2Eth1LinkDown NOTIFICATION-TYPE
+ OBJECTS { eth1Link,
+ alarmEth1Down }
+ STATUS current
+ DESCRIPTION
+ "Local station Ethernet 1 link Up/Down. Supported by RAy2 only."
+ ::= { ray2Traps 9 }
+
+tr2Eth21LinkDown NOTIFICATION-TYPE
+ OBJECTS { eth2Link,
+ alarmEth2Down }
+ STATUS current
+ DESCRIPTION
+ "Local station Ethernet 2 link Up/Down. Supported by RAy2 only."
+ ::= { ray2Traps 10 }
+
+tr2RfPowerFail NOTIFICATION-TYPE
+ OBJECTS { rfPowerStatus,
+ alarmRfPowerFail }
+ STATUS current
+ DESCRIPTION
+ "RF Power amplifier failure. Supported by RAy2 only."
+ ::= { ray2Traps 11 }
+
+tr2NetBitrate NOTIFICATION-TYPE
+ OBJECTS { netBitrate,
+ alarmNetBitrate }
+ STATUS current
+ DESCRIPTION
+ "Air speed below threshold. Supported by RAy2 only."
+ ::= { ray2Traps 12 }
+
+tr2WifiOn NOTIFICATION-TYPE
+ OBJECTS { wifiHAP,
+ alarmWifiOn }
+ STATUS current
+ DESCRIPTION
+ "WiFi Host Access Point is on. Supported by RAy2 only."
+ ::= { ray2Traps 13 }
+
+END