diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/siae/SIAE-RADIO-SYSTEM-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/siae/SIAE-RADIO-SYSTEM-MIB')
| -rw-r--r-- | MIBS/siae/SIAE-RADIO-SYSTEM-MIB | 4692 |
1 files changed, 4692 insertions, 0 deletions
diff --git a/MIBS/siae/SIAE-RADIO-SYSTEM-MIB b/MIBS/siae/SIAE-RADIO-SYSTEM-MIB new file mode 100644 index 0000000..543785e --- /dev/null +++ b/MIBS/siae/SIAE-RADIO-SYSTEM-MIB @@ -0,0 +1,4692 @@ +-- ---------------------------------------------------------------------------- +-- +-- SIAE MICROELETTRONICA s.p.a. +-- +-- Via Michelangelo Buonarroti, 21 +-- 20093 - Cologno Monzese +-- Milano +-- ITALY +-- +-- ---------------------------------------------------------------------------- +-- ---------------------------------------------------------------------------- + +SIAE-RADIO-SYSTEM-MIB + DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, + NOTIFICATION-TYPE, + Integer32, Counter32 + FROM SNMPv2-SMI + InterfaceIndexOrZero + FROM IF-MIB + TEXTUAL-CONVENTION, + DisplayString, RowStatus, StorageType + FROM SNMPv2-TC + siaeMib + FROM SIAE-TREE-MIB + AlarmStatus, AlarmSeverityCode, alarmTrap + FROM SIAE-ALARM-MIB + equipIpSnmpAgentAddress + FROM SIAE-EQUIP-MIB; + + radioSystem MODULE-IDENTITY + LAST-UPDATED "201607140000Z" + ORGANIZATION "SIAE MICROELETTRONICA spa" + CONTACT-INFO + "SIAE MICROELETTONICA s.p.a. + Via Michelangelo Buonarroti, 21 + 20093 - Cologno Monzese + Milano - ITALY + Phone : +39-02-27325-1 + E-mail: help@siaemic.com + " + DESCRIPTION + "Radio System MIB. + " + REVISION "201607140000Z" + DESCRIPTION + "MIB version 01.00.05 + - added radioXpd in radioStatusTable + - deprecated linkXpd in linkStatusTable + " + REVISION "201602290000Z" + DESCRIPTION + "MIB version 01.00.04 + - Added linkXpd to linkStatusTable + - changed MAX-ACCESS clause of linkChRadioSettingsIdx from + read-only to read-create + - Fixed DESCRIPTION of linkSettingsTable + " + REVISION "201509150000Z" + DESCRIPTION + "Fixed DESCRIPTION of radioTxChannelSpacing + " + REVISION "201506180000Z" + DESCRIPTION + "MIB version 01.00.03 + - Added linkConfigurationInProgress and + linkConfigurationInProgressTrapNotification + - Added radio radioRxBerThresholdTable + - Added fadeMarginMeasure + - Deprecated linkFadeMarginMeasure + - Added table radioLoopCapabilityTable + - Added table sspTable + - Added table stm1BulkSettingsTable + - Added table linkE1vsSTM1CapacityTable + - Deprecated linkAcmMaxTDMCapacity + - Deprecated linkTfcTable, linkProTable and linkProMaintTable. + - Added linkTfcV2Table, linkProV2Table and linkProMaintV2Table + in order to replace deprecated tables. + - Added channelSpacingSelection + " + REVISION "201503230000Z" + DESCRIPTION + "Removed alarmTrapNumber from TRAPs and IMPORTS. + " + REVISION "201411050000Z" + DESCRIPTION + "MIB version 01.00.02 + Changes for support of modulation 4096QAM: + - DESCRIPTION of linkBandwidthAndModulation + - ModulationMap TEXTUAL-CONVENTION + - BitsPerSymbol TEXTUAL-CONVENTION + Changes for support of channel spacing 60MHz and 80MHz: + - DESCRIPTION of linkBandwidthAndModulation + - ChannelSpacing TEXTUAL-CONVENTION + " + REVISION "201409160000Z" + DESCRIPTION + "MIB version 01.00.01 + - Added combinedRadioCapabilitiesTable, combinedRadioFrequencyTable, + combinedRadioDuplexFrequencyTable and combinedRadioPowerScalingTable + - Declared deprecated linkCapabilitiesTable, linkFrequencyTable, + linkDuplexFrequencyTable, linkAcmPowerScaling, + linkAcmAtpcRxPowerScaling and linkAcmPowerRange. + - Added linkNotMatchingRadiosAlarm and + linkNotMatchingRadiosAlarmSeverityCode + " + REVISION "201404010000Z" + DESCRIPTION + "Initial version 01.00.00. + " + ::= { siaeMib 80 } + +---------------------------------------------------------------------------------- +-- Textual Conventions +---------------------------------------------------------------------------------- + + ChannelSpacing ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This TC describes a data type which identifies a RF channel spacing. + " + SYNTAX INTEGER { + -- ETSI + bw3M5Hz (0), + bw7Mhz (1), + bw14MHz (2), + bw28MHz (3), + bw40MHz (5), + bw56MHz (4), + bw112MHz (6), + bw250Mhz (7), + bw500Mhz (8), + bw750Mhz (9), + bw1000Mhz (10), + -- FCC + bw10Mhz (11), + bw20Mhz (12), + bw30Mhz (13), + bw50Mhz (14), + bw60Mhz (15), + bw80Mhz (16) + } + + + ModulationMap ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This data type is used as the syntax of the radioBranchModulationMap + and radioBranchRefModulationMap objects. + " + SYNTAX BITS { + modBPSK (0), + mod4QAM (1), + mod8PSK (2), + mod16QAM (3), + mod32QAM (4), + mod64QAM (5), + mod128QAM (6), + mod256QAM (7), + mod512QAM (8), + mod1024QAM (9), + mod2048QAM (10), + mod4096QAM (11) + } + + + ConfigMismatchReason ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This data type is used to specify the cause of Config Mismatch Alarm, + that is the mismatch between the radio link capability and the current + local and remote configuration. + - securityMismatch(0) + Copyright violation + - frequencyFailMismatch(1) + Configured frequency is out of Filter-Bandwidth + - frequencyAlertMismatch(2) + Configured frequency across Filter-Bandwidth + - ptxMismatch(3) + Tx power configured incongruent with RF Tx power limits + - channelSpacingAndModulationMismatch(4) + Bandwidth and/or modulation configured is invalid + (RF doesn't support it) + - remoteConfigurationMismatch(5) + Incongruence between the couple of Terminal Radio Unit (TRU) + in the link: + - Frequency Incongruent (Freq) + - Reference Bandwidth and Modulation incongruent + - Acm-Tx map in congruent with remote Acm-Rx map + - acmMismatch(6) + Obsolete (no longer used) + - profileSetMismatch(7) + The selected profile set is not supported by the TRU + " + SYNTAX BITS { + securityMismatch(0), + frequencyFailMismatch(1), + frequencyAlertMismatch(2), + ptxMismatch(3), + channelSpacingAndModulationMismatch(4), + remoteConfigurationMismatch(5), + acmMismatch(6), + profileSetMismatch(7) + } + + RadioCapability ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This data type is used as the syntax of the radioBranchKeyFeatures + objects. + " + SYNTAX BITS { + reserved (0), + trafficSquelch (1), + baseBandLoop (2), + maxPower (3), + carrierOnly (4), + iQLoop (5), + rfLoopGivenMod (6), -- only at a given modulation + rfLoopAnyMod (7) -- at any modulation + } + + BitsPerSymbol ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "his TC describes a data type which identifies a RF channel spacing. + " + SYNTAX INTEGER { + bpsBPSK (1), + bps4QAM (2), + bps8PSK (3), + bps16QAM (4), + bps32QAM (5), + bps64QAM (6), + bps128QAM (7), + bps256QAM (8), + bps512QAM (9), + bps1024QAM (10), + bps2048QAM (11), + bps4096QAM (12) + } + + Stm1IndexOrZero ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "This textual convention permits the + additional value of zero to an stm1Index in stm1Table. + The value zero is object-specific and must therefore be + defined as part of the description of any object which + uses this syntax. Examples of the usage of zero might + include situations where stm-1 was unknown, or when none + or all stm-1s need to be referenced." + SYNTAX Integer32 (0..2147483647) + +---------------------------------------------------------------------------------- +-- radioSystem GROUP +---------------------------------------------------------------------------------- +-- +-- This group contains all the objects that are specific of the radio system +-- +---------------------------------------------------------------------------------- + +------ Beginning -------------------------------------------------------------- + + radioSystemMibVersion OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Numerical version of this module. + The string version of this MIB have the following format: + XX.YY.ZZ + so, for example, the value 1 should be interpreted as 00.00.01 + and the value 10001 should be interpreted as 01.00.01." + ::= {radioSystem 1} + +------- Begin of radioTable +-- + radioTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of radio interface entries. This table is useful + to show the manager all the available radio interfaces + on the equipment. Moreover it is a reference for + Performance Monitoring (PWR and G828). + " + ::= {radioSystem 2} + + radioEntry OBJECT-TYPE + SYNTAX RadioEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing management information applicable to a + particular radio interface. + " + INDEX {radioIndex} + ::= {radioTable 1} + + RadioEntry ::= + SEQUENCE { + radioIndex Integer32, + radioLabel DisplayString, + radioType INTEGER, + radioIfIndex InterfaceIndexOrZero, + radioStorageType StorageType + } + + radioIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique value, greater than zero, for each radio + interface. It is recommended that values are assigned + contiguously starting from 1. + " + ::= {radioEntry 1} + + radioLabel OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual string containing information about the radio + interface. This string should include the name of the + manufacturer, the product name and the version of the + interface hardware/software. + " + ::= {radioEntry 2} + + radioType OBJECT-TYPE + SYNTAX INTEGER { + other(1), + analogRadio(2), -- analogic radio -- + digitalRadio(3), -- digital radio -- + xpicRadio(4) -- xpic radio -- + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of interface. + " + ::= {radioEntry 3} + + radioIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object defines a greater than zero value + to identify an interface in ifTable or a zero + value if ifTable is not supported. + " + ::= {radioEntry 4} + + radioStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The storage type of this conceptual row. Conceptual + rows having the value 'permanent' need not allow + write-access to any columnar objects in the row. + " + ::= {radioEntry 5} + +-- +------- End of radioTable + +------- Begin of xpicTable +-- + xpicTable OBJECT-TYPE + SYNTAX SEQUENCE OF XpicEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of xpic radio interface entries. If a manager + wants to make an xpic link, it should only add a + particular xpic radio interface to an xpic link. + " + ::= {radioSystem 3} + + xpicEntry OBJECT-TYPE + SYNTAX XpicEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing management information applicable to a + particular xpic radio interface. + " + INDEX {xpicIndex} + ::= {xpicTable 1} + + XpicEntry ::= + SEQUENCE { + xpicIndex Integer32, + xpicRadioIdx Integer32, + xpicRowstatus RowStatus + } + + xpicIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique value, greater than zero, for each xpic radio + interface. It is recommended that values are assigned + contiguously starting from 1. + " + ::= {xpicEntry 1} + + xpicRadioIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Index of xpic radio interface, corresponding + to an available xpic radio interface in radioTable. + " + ::= {xpicEntry 2} + + xpicRowstatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this conceptual row in xpicTable. + " + ::= {xpicEntry 3} + +-- +------- End of xpicTable + +------- Begin of xpicChTable +-- + xpicChTable OBJECT-TYPE + SYNTAX SEQUENCE OF XpicChEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of xpic channel entries. This table maps + each xpic radio in respective xpic radio interface. + " + ::= {radioSystem 4} + + xpicChEntry OBJECT-TYPE + SYNTAX XpicChEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing management information applicable to a + particular xpic channel. It defines radio interface and + polarization for a given xpic channel. + " + INDEX {xpicIndex, + xpicChPolIndex} + ::= {xpicChTable 1} + + XpicChEntry ::= + SEQUENCE { + xpicChPolIndex Integer32, + xpicChRadioIdx Integer32, + xpicChRowstatus RowStatus + } + + xpicChPolIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the xpic radio polarization. + " + ::= {xpicChEntry 1} + + xpicChRadioIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Xpic radio interface, corresponding to a radio interface + in radioTable, used to make up the given xpic radio interface. + " + ::= {xpicChEntry 2} + + xpicChRowstatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this conceptual row in xpicChTable. + " + ::= {xpicChEntry 3} + +-- +------- End of xpicChTable + + linkAvailableIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows an index which is available for creation of a new link + in the system. It shows the smallest available index. + Any attempt to create a link with a different index results + in a failure. + " + ::= {radioSystem 5} + +------- Begin of linkTable +-- + linkTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of link entries. + " + ::= {radioSystem 6} + + linkEntry OBJECT-TYPE + SYNTAX LinkEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing management information applicable to a + particular link. + " + INDEX {linkIndex} + ::= {linkTable 1} + + LinkEntry ::= + SEQUENCE { + linkIndex Integer32, + linkType INTEGER, + linkLabel DisplayString, + linkIfIndex InterfaceIndexOrZero, + linkRowstatus RowStatus + } + + linkIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique value, greater than zero, for each link. + Manager must use the first available index, + suggested by linkAvailableIndex. + " + ::= {linkEntry 1} + + linkType OBJECT-TYPE + SYNTAX INTEGER { + radio1p0(1), -- 1+0 + radio1p1HS(2), -- 1+1 Hot Standby + radio1p1FD(3), -- 1+1 Frequency Diversity + radio2p0Xpic(4), -- 2+0 XPIC + radio2p2XpicHS(5), -- 2+2 XPIC Hot Standby + radio2p2XpicFD(6), -- 2+2 XPIC Frequency Diversity + radioNp1(7) -- N+1 + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object identifies link type. Supported link types are: + single link, 1+1 Hot Standby, 1+1 Frequency Diversity, 2+0 XPIC, + 2+2 XPIC Hot Standby, 2+2 XPIC Frequency Diversity and N+1. + " + DEFVAL {radio1p0} + ::= {linkEntry 2} + + linkLabel OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A textual string containing information about the link. + This string should give more details about link specific + parameters. + " + DEFVAL {""} + ::= {linkEntry 3} + + linkIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object defines a greater than zero value + to identify a link in ifTable or a zero + value if ifTable is not supported. + " + DEFVAL {0} + ::= {linkEntry 4} + + linkRowstatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this row of linkTable. This object is used to manage the + creation and deletion of conceptual rows in linkTable. + To create a row in this table, a manager should set rowstatus to + createAndWait(5) and choose a link type. Respective entries in + linkSettingsTable, linkStatusTable and tdmSettingsTable will be + created by agent.In case of protection links proper entries in + linkProtectionTable will be also created. + Until instances of all corresponding columns are appropriately + configured, the value of the corresponding instance of rowstatus + is notReady(3). + When there is sufficient information to (attempt to) make the + conceptual row available for use by the managed device, + then the rowstatus column turns into notInService(2); manager + must set rowstatus to active(1) to make the conceptual row + active. + The contents of linkSettingsTable and radioSettingsTable can be + changed only if this object is notInService(2). + " + ::= {linkEntry 5} + +-- +------- End of linkTable + +------- Begin of linkChTable +-- + linkChTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkChEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of link channel entries. + " + ::= {radioSystem 7} + + linkChEntry OBJECT-TYPE + SYNTAX LinkChEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing management information applicable to a + particular link channel. + " + INDEX {linkIndex, + linkChIndex} + ::= {linkChTable 1} + + LinkChEntry ::= + SEQUENCE { + linkChIndex Integer32, + linkChRadioIdx Integer32, + linkChRadioSettingsIdx Integer32, + linkChRowstatus RowStatus + } + + linkChIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link Channel Index. + " + ::= {linkChEntry 1} + + linkChRadioIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Radio channel index that corresponds to an + available radio interface in radioTable. + " + ::= {linkChEntry 2} + + linkChRadioSettingsIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Radio Settings Index. This object is a foreign + key for a corresponding radioSettingsTable entry, + which is automatically created by agent. + " + DEFVAL {0} + ::= {linkChEntry 3} + + linkChRowstatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this row of linkChTable. This object is used + to manage the creation and deletion of conceptual rows in + linkChTable. + To create a row in this table, a manager should set rowstatus to + createAndWait(5). Until instances of all corresponding columns + are appropriately configured, the value of the corresponding + instance of rowstatus is notReady(3). + When there is sufficient information to (attempt to) make the + conceptual row available for use by the managed device, + then the rowstatus column turns into notInService(2); manager + must set rowstatus to active(1) to make the conceptual row + active. + The content of radioSettingsTable can be changed only if this + object is notInService(2). + " + ::= {linkChEntry 4} +-- +------- End of linkChTable + +------- Begin of linkSettingsTable +-- + linkSettingsTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkSettingsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with link settings entries. This table contains all + parameters of a radio frequency link. The content of this + table can be changed by a manager if linkRowStatus is + notInService(2)." + ::= {radioSystem 8} + + linkSettingsEntry OBJECT-TYPE + SYNTAX LinkSettingsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Radio link entry" + INDEX {linkIndex} + ::= {linkSettingsTable 1} + + LinkSettingsEntry ::= + SEQUENCE { + linkBandwidthAndModulation Integer32, + linkAcmEngineEnable INTEGER, + linkTxUpperProfile INTEGER, + linkTxLowerProfile INTEGER, + linkId INTEGER, + linkTxPwrThresh INTEGER, + linkRxPwrThresh INTEGER, + linkSynchSetupProtocolEnable INTEGER, + linkProfilesSetSelection INTEGER, + linkXpicControlProcedure INTEGER + } + + linkBandwidthAndModulation OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Link Modulation and Bandwidth (channel spacing). + The value of this object value is computed by: + 65536*modulation+bandwidth + where bandwidth selection is: + 0 = 3.5Mhz + 1 = 7MHz + 2 = 14MHz + 3 = 28MHz + 4 = 56MHz + 5 = 10MHz + 6 = 20MHz + 7 = 30MHz + 8 = 40MHz + 9 = 50MHz + 10 = 112Mhz + 11 = 250Mhz + 12 = 500Mhz + 13 = 750Mhz + 14 = 1Ghz + 15 = 60MHz + 16 = 80MHz + and modulation is in bit-per-symbol: + 1 = BPSK + 2 = 4QAM + 3 = 8PSK + 4 = 16QAM + 5 = 32QAM + 6 = 64QAM + 7 = 128QAM + 8 = 256QAM + 9 = 512QAM + 10 = 1024QAM + 11 = 2048QAM. + 12 = 4096QAM. + + Examples: + 250Mhz-4QAM (131083), + 500Mhz-4QAM (131084), + 250Mhz-16QAM (262155), + 500Mhz-64QAM (393228). + + Note: 0 bit-per-symbol is not possible, + so value 0 is used for + BandwidthAndModulation unassigned." + ::= {linkSettingsEntry 1} + + linkAcmEngineEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to enable/disable the ACM engine" + DEFVAL { disable } + ::= {linkSettingsEntry 2} + + linkTxUpperProfile OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The object (and linkTxLowerProfile object) is used to + restrict the TX profile range when ACM is enabled." + ::= {linkSettingsEntry 3} + + linkTxLowerProfile OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The object (and linkTxUpperProfile object) is used to + restrict the TX profile range when ACM is enabled." + ::= {linkSettingsEntry 4} + + linkId OBJECT-TYPE + SYNTAX INTEGER (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Link Identification (value 0..255)" + DEFVAL {0} + ::= {linkSettingsEntry 5} + + linkTxPwrThresh OBJECT-TYPE + SYNTAX INTEGER (3..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Threshold (value +3 , +15 dB) relative to nominal value of the TX power + below wich the related alarm is set." + DEFVAL {3} + ::= {linkSettingsEntry 6} + + linkRxPwrThresh OBJECT-TYPE + SYNTAX INTEGER (-99..-40) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Threshold (value -40 , -99 dBm) for RX power below wich the related + alarm is set." + DEFVAL {-70} + ::= {linkSettingsEntry 7} + + linkSynchSetupProtocolEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Synchronization Setup Protocol (SSP) control" + DEFVAL {disable} + ::= {linkSettingsEntry 8} + + linkProfilesSetSelection OBJECT-TYPE + SYNTAX INTEGER { + highThroughput (1), + highGain (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Selection of the working profile set between high gain + (max robustness) profile set and high throughput (max + capacity) profile set. The set of profiles high gain + features a greater robustness against to the set of + profiles high throughput. + For radio systems that do not have more sets of profiles, + this object becomes read only and its reading shows the + only one set of profiles supported. + " + DEFVAL {highThroughput} + ::= {linkSettingsEntry 9} + + linkXpicControlProcedure OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Set by manager to enable\disable XPIC alarm control procedure. + Only for XPIC configurations." + DEFVAL { enable } + ::= {linkSettingsEntry 10} + +-- +------- End of linkSettingsTable + +------- Begin of radioSettingsTable +-- + radioSettingsTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioSettingsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with radio settings entries. This table contains all + parameters of a radio terminal. The content of this table + can be changed only linkRowStatus is notInService(2)" + ::= {radioSystem 9} + + radioSettingsEntry OBJECT-TYPE + SYNTAX RadioSettingsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Radio terminal entry" + INDEX {radioSettingsIndex} + ::= {radioSettingsTable 1} + + RadioSettingsEntry ::= + SEQUENCE { + radioSettingsIndex Integer32, + radioSettingsRowStatus RowStatus, + radioSettingsLabel DisplayString, + radioTxFrequency INTEGER, + radioDuplexFrequency INTEGER, + radioTxAttenuation INTEGER, + radioAtpcManual INTEGER, + radioAtpcPwrHigh Integer32, + radioAtpcPwrLow Integer32, + radioAtpcRange Integer32, + radioFreqTableSelection ChannelSpacing + } + + radioSettingsIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Radio settings index. + " + ::= {radioSettingsEntry 1} + + radioSettingsRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this row. + " + ::= {radioSettingsEntry 2} + + radioSettingsLabel OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual string containing information about the radio + interface. + " + ::= {radioSettingsEntry 3} + + radioTxFrequency OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Transmitted frequency in KHz. Null value means invalid frequency." + DEFVAL {0} + ::= {radioSettingsEntry 4} + + radioDuplexFrequency OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Value of duplex frequency in KHz. -2 means not set." + DEFVAL {-2} + ::= {radioSettingsEntry 5} + + radioTxAttenuation OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Transmitter attenuation relative to nominal power (dBm)." + ::= {radioSettingsEntry 6} + + radioAtpcManual OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Enables/disables Atpc Manual operation." + DEFVAL {disable} + ::= {radioSettingsEntry 7} + + radioAtpcPwrHigh OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ATPC Control - Local Rx Power High (dBm range -30 to -80) -." + DEFVAL {-40} + ::= {radioSettingsEntry 8} + + radioAtpcPwrLow OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ATPC Control - Local Rx Power Low (dBm range -30 to -80) -." + DEFVAL {-60} + ::= {radioSettingsEntry 9} + + radioAtpcRange OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the range of the ATPC regulation (expressed in dB) with respect + to the current value of maximum Tx output, that is intended as the upper + limit of the range. A null value means no limit: the lower limit + of the range is equal to minimum Ptx." + DEFVAL {0} + ::= {radioSettingsEntry 10} + + radioFreqTableSelection OBJECT-TYPE + SYNTAX ChannelSpacing + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "RadioFrequencyTable key (channel spacing & modulation) selection." + ::= {radioSettingsEntry 11} + +-- +------- End of radioSettingsTable + +------- Begin of tdmSettingsTable +-- + tdmSettingsTable OBJECT-TYPE + SYNTAX SEQUENCE OF TdmSettingsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with tdm settings entries. + " + ::= {radioSystem 10} + + tdmSettingsEntry OBJECT-TYPE + SYNTAX TdmSettingsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing tdm parameters for a particular link. + " + INDEX {linkIndex, + tdmPolIndex} + ::= {tdmSettingsTable 1} + + TdmSettingsEntry ::= + SEQUENCE { + tdmPolIndex Integer32, + tdmE1Channel Integer32, + tdmE1Framer INTEGER + } + + tdmPolIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Polarization index. + " + ::= {tdmSettingsEntry 1} + + tdmE1Channel OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of E1 channels. This object is used to define the capacity + of E1 tributaries assigned to a given radio link. The capacity is + changed in steps of E1 (2Mbit/s). + " + DEFVAL {0} + ::= {tdmSettingsEntry 2} + + tdmE1Framer OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to attach the framer to a given E1. + " + DEFVAL {disable} + ::= {tdmSettingsEntry 3} + +-- +------- End of tdmSettingsTable + +------- Begin of radioCapabilitiesTable +-- + radioCapabilitiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioCapabilitiesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with RadioCapabilities entries: there is an entry for each + radioTable rows." + ::= {radioSystem 11} + + radioCapabilitiesEntry OBJECT-TYPE + SYNTAX RadioCapabilitiesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "RadioCapabilities entry." + INDEX {radioIndex} + ::= {radioCapabilitiesTable 1} + + RadioCapabilitiesEntry ::= + SEQUENCE { + radioCapabilitiesCapability RadioCapability, + radioCapabilitiesTxMinFrequency Integer32, + radioCapabilitiesTxMaxFrequency Integer32, + radioCapabilitiesStepFrequency Integer32, + radioCapabilitiesMinPtxNominalValue Integer32, + radioCapabilitiesMaxPtxNominalValue Integer32, + radioCapabilitiesExtendedMinPwr Integer32 + } + + radioCapabilitiesCapability OBJECT-TYPE + SYNTAX RadioCapability + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bit map to describe the radio features." + ::= {radioCapabilitiesEntry 1} + + radioCapabilitiesTxMinFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum of available channel frequency in KHz." + ::= {radioCapabilitiesEntry 2} + + radioCapabilitiesTxMaxFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum of available channel frequency in KHz." + ::= {radioCapabilitiesEntry 3} + + radioCapabilitiesStepFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum frequency step in KHz." + ::= {radioCapabilitiesEntry 4} + + radioCapabilitiesMinPtxNominalValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum nominal Ptx in dBm." + ::= {radioCapabilitiesEntry 5} + + radioCapabilitiesMaxPtxNominalValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum nominal Ptx in dBm." + ::= {radioCapabilitiesEntry 6} + + radioCapabilitiesExtendedMinPwr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum extended Ptx power for fade margin." + ::= {radioCapabilitiesEntry 7} +-- +------- End of radioCapabilitiesTable + +------- Begin of radioStatusTable +-- + radioStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with RadioStatus records: one record for 1+0 configuration and + two record for 1+1 configuration." + ::= {radioSystem 12} + + radioStatusEntry OBJECT-TYPE + SYNTAX RadioStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "RadioStatus record." + INDEX {radioIndex} + ::= {radioStatusTable 1} + + RadioStatusEntry ::= + SEQUENCE { + radioCurrentDuplexFrequency Integer32, + radioTxChannelSpacing Integer32, + radioPrx Integer32, + radioPtx Integer32, + radioNormalizedMse Integer32, + radioRxActiveStatus INTEGER, + radioTxActiveStatus INTEGER, + radioCableOpenAlarm AlarmStatus, + radioCableShortAlarm AlarmStatus, + radioInvalidFrequencyAlarm AlarmStatus, + radioBaseBandRxAlarm AlarmStatus, + radioModulatorFailAlarm AlarmStatus, + radioDemodulatorFailAlarm AlarmStatus, + radioRxPowerLowAlarm AlarmStatus, + radioTxPowerLowAlarm AlarmStatus, + radioRemDemodulatorFailAlarm AlarmStatus, + radioVcoFailAlarm AlarmStatus, + radioRxIFAgcAlarm AlarmStatus, + radioTxIFAgcAlarm AlarmStatus, + radioIduOduCommunicationAlarm AlarmStatus, + radioOduIduCommunicationAlarm AlarmStatus, + radioLocalOduAlarmSynthesis AlarmStatus, + radioRemoteOduAlarmSynthesis AlarmStatus, + radioConfigMismatchAlarm AlarmStatus, + radioConfigAlarmReason ConfigMismatchReason, + radioRxQualityLowAlarm AlarmStatus, + radioRxQualityWarningAlarm AlarmStatus, + radioXpd Integer32 + } + + radioCurrentDuplexFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Spacing between transmitted and received frequency in KHz." + ::= {radioStatusEntry 1} + + radioTxChannelSpacing OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Half of transmitted signal channel spacing in KHz." + ::= {radioStatusEntry 2} + + radioPrx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Received power level (dBm)." + ::= {radioStatusEntry 3} + + radioPtx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Transmitted power level (dBm)." + ::= {radioStatusEntry 4} + + radioNormalizedMse OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Normalized MSE (Mean Squared Error) is an indicator of the Signal + to Noise (S/N) ratio. It's in 0.1 dB steps" + ::= {radioStatusEntry 5} + + radioRxActiveStatus OBJECT-TYPE + SYNTAX INTEGER { + cleared (1), + active (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Receiver Active status with associated Severity + In 1+1 Hot Standby radio system, only one RX is active. + RXs are active in other configurations of the radio system. + " + ::= {radioStatusEntry 6} + + radioTxActiveStatus OBJECT-TYPE + SYNTAX INTEGER { + cleared (1), + active (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Transmitter Active status with associated Severity. + In 1+1 Hot Standby radio system, only one TX is active. + TXs are active in other configurations of the radio system. + " + ::= {radioStatusEntry 7} + + radioCableOpenAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Cable connnecting ODU is open: alarm status with associated + severity. + " + ::= {radioStatusEntry 8} + + radioCableShortAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Cable connnecting ODU is in short-circuit: alarm status + with associated severity. + " + ::= {radioStatusEntry 9} + + radioInvalidFrequencyAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Invalid frequency alarm with associated severity." + ::= {radioStatusEntry 10} + + radioBaseBandRxAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Base Band Rx alarm status with associated severity." + ::= {radioStatusEntry 11} + + radioModulatorFailAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator Fail Alarm status with associated severity." + ::= {radioStatusEntry 12} + + radioDemodulatorFailAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Demodulator Fail Alarm status with associated severity." + ::= {radioStatusEntry 13} + + radioRxPowerLowAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Receiver power low alarm status with associated severity." + ::= {radioStatusEntry 14} + + radioTxPowerLowAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Transmitter power low alarm status with associated severity." + ::= {radioStatusEntry 15} + + radioRemDemodulatorFailAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote Demodulator Fail Alarm status with associated severity." + ::= {radioStatusEntry 16} + + radioVcoFailAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "RT VCO fail alarm status with associated severity." + ::= {radioStatusEntry 17} + + radioRxIFAgcAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "RT Rx IF AGC fail alarm status with associated severity." + ::= {radioStatusEntry 18} + + radioTxIFAgcAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "RT Tx IF AGC fail alarm status with associated severity." + ::= {radioStatusEntry 19} + + radioIduOduCommunicationAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Communication from IDU towards ODU is down" + ::= {radioStatusEntry 20} + + radioOduIduCommunicationAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Communication from ODU towards IDU is down" + ::= {radioStatusEntry 21} + + radioLocalOduAlarmSynthesis OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Local ODU alarm synthesis with associated severity." + ::= {radioStatusEntry 22} + + radioRemoteOduAlarmSynthesis OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Local ODU alarm synthesis alarm status with associated severity." + ::= {radioStatusEntry 23} + + radioConfigMismatchAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Config Mismatch alarm status with associated severity and related map." + ::= {radioStatusEntry 24} + + radioConfigAlarmReason OBJECT-TYPE + SYNTAX ConfigMismatchReason + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bit map to describe the Config Mismatch Alarm" +-- DEFVAL { { } } + ::= {radioStatusEntry 25} + + radioRxQualityLowAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High BER Alarm status with associated severity." + ::= {radioStatusEntry 26} + + radioRxQualityWarningAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The RX signal is close to cause errors on payload." + ::= {radioStatusEntry 27} + + radioXpd OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Cross-Polarization Discrimination, in tenths of dB, is the + difference between the received signal power of the + co-polarized main beam, and it componemt received on the + cross-polarized signal. + This object shows an extimated value of the XPD performed by + the cross-polarization interference canceller (XPIC). + This means that the measure is reliable if: + - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5), + or radio2p2XpicFD(6)) + - Alarm radioDemodulatorFailAlarm is cleared. + - XPD is not too high, since without cross-polar interference + the canceller is not able to works well. Basically, in this + condition, the extimated XPD is greater than the real one. + " + ::= {radioStatusEntry 28} +-- +------- End of radioStatusTable + +-- +-- MAINTENANCE TABLE +-- + +------- Begin of radioMaintTable +-- + radioMaintTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioMaintEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with Command for maintenance of radio branch. + Objects in this table is not persistent. An Instance of this + table is created on creation of radioBranchEntry" + ::= {radioSystem 13} + + radioMaintEntry OBJECT-TYPE + SYNTAX RadioMaintEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Radio branch Maintenance record." + INDEX {radioIndex} + ::= {radioMaintTable 1} + + RadioMaintEntry ::= + SEQUENCE { + radioTxStatus INTEGER, + radioCarrierOnly INTEGER, + radioLoop INTEGER, + radioRFLoopTestResult INTEGER, + radioRFLoopTestPercTime INTEGER, + radioRtPsuOff INTEGER, + radioLom INTEGER, + radioXpic INTEGER + } + + radioTxStatus OBJECT-TYPE + SYNTAX INTEGER { + transmitterOff (1), + transmitterOn (2), + permanentOff (3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Transmitter status control. + The value transmitterOff(1) is related to a manual operation. + The value permanentOff(3) is persistent across restart. + " + DEFVAL {transmitterOn} + ::= {radioMaintEntry 1} + + radioCarrierOnly OBJECT-TYPE + SYNTAX INTEGER { + carrierOnlyOff (1), + carrierOnlyOn (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Carrier only transmission control." + DEFVAL {carrierOnlyOff} + ::= {radioMaintEntry 2} + + radioLoop OBJECT-TYPE + SYNTAX INTEGER { + loopOff (1), + rfLoop (2), + iqLoop (3), + baseBandLoop (4), + rfLoopAtFixedMod (6), + baseBandLoopEthSquelch (7), + rfLoopAtFixedModEthSquelch(8), + iqloopEthSquelch (9) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/disables the Radio Branch loops." + DEFVAL {loopOff} + ::= {radioMaintEntry 3} + + radioRFLoopTestResult OBJECT-TYPE + SYNTAX INTEGER { + testNone (0), + testRunning (1), + testNotPossible (2), + testPassed (3), + testFail (4), + testInterrupted (5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Radio branch RT loop test result." + DEFVAL {testNone} + ::= {radioMaintEntry 4} + + radioRFLoopTestPercTime OBJECT-TYPE + SYNTAX INTEGER (0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Radio branch RT loop test time percentage" + ::= {radioMaintEntry 5} + + radioRtPsuOff OBJECT-TYPE + SYNTAX INTEGER { + rtPsuOff (1), + rtPsuOn (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "It switches on/off the Rt power supply" + DEFVAL {rtPsuOn} + ::= {radioMaintEntry 6} + + radioLom OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "It is used to enable the IP packet forwarding towards Radio." + DEFVAL {disable} + ::= {radioMaintEntry 7} + + radioXpic OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable of the cross polarization interference cancellation of this + radio. The value disable is tied to a manual operation + (ManOpRecord). This object is applicable only if thiis radio + belongs to a 2+0 XPIC or 2+2 XPIC link." + ::= {radioMaintEntry 8} + +-- +------- End of radioMaintTable + +------- Begin of radioFrequencyTable +-- + radioFrequencyTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioFreqEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Availables channels for selected channel spacing and modulation + (see leaf radioFreqTableSelection)." + ::= {radioSystem 14} + + radioFreqTabEntry OBJECT-TYPE + SYNTAX RadioFreqEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "RadioFreqTab record." + INDEX {radioIndex, radioFreqChannelId} + ::= {radioFrequencyTable 1} + + RadioFreqEntry ::= + SEQUENCE { + radioFreqChannelId Integer32, + radioFreqChannelNum Integer32, + radioFreqValue Integer32 + } + + radioFreqChannelId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index of the table" + ::= {radioFreqTabEntry 1} + + radioFreqChannelNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Available channel number." + ::= {radioFreqTabEntry 2} + + radioFreqValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency related to radioFreqChannelNum." + ::= {radioFreqTabEntry 3} +-- +------- End of radioFrequencyTable + +------- Begin of radioDuplexFrequencyTable +-- + radioDuplexFrequencyTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioDuplexFreqEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with available duplex frequencies. Duplex frequency is + the absolute value of difference between RX and TX frequency." + ::= {radioSystem 15} + + radioDuplexFreqEntry OBJECT-TYPE + SYNTAX RadioDuplexFreqEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Duplex Frequency entry. There is an entry for each available + duplex frequency." + INDEX {radioIndex, radioDuplexFreqId} + ::= {radioDuplexFrequencyTable 1} + + RadioDuplexFreqEntry ::= + SEQUENCE { + radioDuplexFreqId Integer32, + radioDuplexFreqValue Integer32 + } + + radioDuplexFreqId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index of the table." + ::= {radioDuplexFreqEntry 1} + + radioDuplexFreqValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Duplex frequency in KHz." + ::= {radioDuplexFreqEntry 2} +-- +------- End of radioDuplexFrequencyTable + +------- Begin of radioModulationTable +-- + radioModulationTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioModulationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "List of modulations related to channel spacing." + ::= {radioSystem 16} + + radioModulationEntry OBJECT-TYPE + SYNTAX RadioModulationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "radioModulation record." + INDEX {radioIndex, radioChannelSpacing} + ::= {radioModulationTable 1} + + RadioModulationEntry ::= + SEQUENCE { + radioChannelSpacing ChannelSpacing, + radioModulationMap ModulationMap, + radioRefModulationMap ModulationMap + } + + radioChannelSpacing OBJECT-TYPE + SYNTAX ChannelSpacing + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the channel spacing." + ::= {radioModulationEntry 1} + + radioModulationMap OBJECT-TYPE + SYNTAX ModulationMap + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of modulations in the radioChanSpacing" + ::= {radioModulationEntry 2} + + radioRefModulationMap OBJECT-TYPE + SYNTAX ModulationMap + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of modulations that can be selected as reference + in the radioChanSpacingId" + ::= {radioModulationEntry 3} +-- +------- End of radioModulationTable + +------- Begin of linkStatusTable +-- + linkStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with LinkStatusEntry." + ::= {radioSystem 17} + + linkStatusEntry OBJECT-TYPE + SYNTAX LinkStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Link status entry" + INDEX {linkIndex, + linkPolIndex } + ::= {linkStatusTable 1} + + LinkStatusEntry ::= + SEQUENCE{ + linkPolIndex INTEGER, + linkAcmRxProfile Integer32, + linkAcmTxProfile Integer32, + linkAcmRxProfileLabel DisplayString, + linkAcmTxProfileLabel DisplayString, + linkAcmRxModulation BitsPerSymbol, + linkAcmTxModulation BitsPerSymbol, + linkAcmRxCode INTEGER, + linkAcmTxCode INTEGER, + linkTxETHCapacity Integer32, + linkRxETHCapacity Integer32, + linkTxTDMCapacity Integer32, + linkRxTDMCapacity Integer32, + linkRescueModulation BitsPerSymbol, + linkReducedCapacityAlarm AlarmStatus, + linkLinkTelemetryFailAlarm AlarmStatus, + linkIdMismatchAlarm AlarmStatus, + linkRadioEocAlarm AlarmStatus, + linkSetupMismatchAlarm AlarmStatus, + linkRescueSetupAlarm AlarmStatus, + linkXpicProcedureBlockAlarm AlarmStatus, + linkXpicRemTxOffAlarm AlarmStatus, + linkRemoteIduAlarmSynthesis AlarmStatus, + linkNotMatchingRadiosAlarm AlarmStatus, + linkConfigurationInProgress INTEGER, + linkXpd Integer32 + } + + linkPolIndex OBJECT-TYPE + SYNTAX INTEGER (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the radio polarization. In XPIC radio link + identifies one of the polarizations." + ::= {linkStatusEntry 1} + + linkAcmRxProfile OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports the ACM profile number in use in the radio Rx. + It is the linkAcmProfileId of linkAcmTable. + Label is linkAcmProfileLabel from linkAcmTable" + ::= {linkStatusEntry 2} + + linkAcmTxProfile OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports the ACM profile number in use in the radio Tx. + It is the linkAcmProfileId of linkAcmTable. + Label is linkAcmProfileLabel from linkAcmTable" + ::= {linkStatusEntry 3} + + linkAcmRxProfileLabel OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ASCII string used to describe current acm rx profile" + ::= {linkStatusEntry 4} + + linkAcmTxProfileLabel OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ASCII string used to describe current acm tx profile" + ::= {linkStatusEntry 5} + + linkAcmRxModulation OBJECT-TYPE + SYNTAX BitsPerSymbol + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the type of modulation of the Rx profile in use." + ::= {linkStatusEntry 6} + + linkAcmTxModulation OBJECT-TYPE + SYNTAX BitsPerSymbol + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the type of modulation of the Tx profile in use." + ::= {linkStatusEntry 7} + + linkAcmRxCode OBJECT-TYPE + SYNTAX INTEGER { + unknown (0), + normal (1), + strong (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the type of codificator of the Rx profile in use." + ::= {linkStatusEntry 8} + + linkAcmTxCode OBJECT-TYPE + SYNTAX INTEGER { + unknown (0), + normal (1), + strong (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the type of codificator of the Tx profile in use." + ::= {linkStatusEntry 9} + + linkTxETHCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports (in Kbits/sec) the transmitted payload + capacity used by the Ethernet" + DEFVAL { 0 } + ::= {linkStatusEntry 10} + + linkRxETHCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports (in Kbits/sec) the received payload capacity + used by the Ethernet" + DEFVAL { 0 } + ::= {linkStatusEntry 11} + + linkTxTDMCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports the capacity in kbit/sec reserved to TDM + tributaries in tx ACM profile." + DEFVAL { 0 } + ::= {linkStatusEntry 12} + + linkRxTDMCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports the capacity in kbit/sec reserved to TDM + tributaries in rx ACM profile." + DEFVAL { 0 } + ::= {linkStatusEntry 13} + + linkRescueModulation OBJECT-TYPE + SYNTAX BitsPerSymbol + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the modulation used when the remote terminal is + unreachable, ie traffic on radio link is down." + DEFVAL { bps4QAM } + ::= {linkStatusEntry 14} + + linkReducedCapacityAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The equipment works in reduced capacity" + ::= {linkStatusEntry 15} + + linkLinkTelemetryFailAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fail of link telemetry communication channel with associated + Severity" + ::= {linkStatusEntry 16} + + linkIdMismatchAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link Identification Alarm with associated Severity" + ::= {linkStatusEntry 17} + + linkRadioEocAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fail of Radio Eoc link communication channel with associated + Severity" + ::= {linkStatusEntry 18} + + linkSetupMismatchAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The local setup doesn't match the setup of remote terminal" + ::= {linkStatusEntry 19} + + linkRescueSetupAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The equipment is using the setup relative to the rescue modulation" + ::= {linkStatusEntry 20} + + linkXpicProcedureBlockAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Only for XPIC equipment configurations. + Equipment Controller XPIC procedure Alarm control with associated + Severity" + ::= {linkStatusEntry 21} + + linkXpicRemTxOffAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Only for XPIC equipment configurations. + Remote TX OFF command with associated Severity" + ::= {linkStatusEntry 22} + + linkRemoteIduAlarmSynthesis OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synthesis of the remote IDU alarms" + ::= {linkStatusEntry 23} + + linkNotMatchingRadiosAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Radios of the link does not have matched parameters." + ::= {linkStatusEntry 24} + + linkConfigurationInProgress OBJECT-TYPE + SYNTAX INTEGER { + cleared (1), + active (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The link is being configured and the table linkSettingsTable is + not available for modifying parameters. + " + ::= {linkStatusEntry 25} + + linkXpd OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Cross-Polarization Discrimination, in tenths of dB, is the + difference between the received signal power of the + co-polarized main beam, and it componemt received on the + cross-polarized signal. + This object shows an extimated value of the XPD performed by + the cross-polarization interference canceller (XPIC). + This means that the measure is reliable if: + - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5), + or radio2p2XpicFD(6)) + - Alarm radioDemodulatorFailAlarm is cleared. + - XPD is not too high, since without cross-polar interference + the canceller is not able to works well. Basically, in this + condition, the extimated XPD is greater than the real one. + " + ::= {linkStatusEntry 26} + +-- +------- End of linkStatusTable + +------- Begin of linkTfcTable +-- + linkTfcTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkTfcEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "Transmitter Fail Check feature. In 1+1 HS configuration, the + radio terminal that doesn't receive signals on both receivers, + requests the remote transmitter switch. + + This table was deprecated and replaced by linkTfcV2Table. + It is a view of the rows of the linkTfcV2Table with the same + linkIndex and linkPolIndex equal to 1, in order to ensure + compatibility with old SNMP managers. + " + ::= {radioSystem 18} + + linkTfcEntry OBJECT-TYPE + SYNTAX LinkTfcEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "Radio link TFC entry." + INDEX {linkIndex} + ::= {linkTfcTable 1} + + LinkTfcEntry ::= + SEQUENCE { + linkTfcAction INTEGER, + linkTfcControl INTEGER, + linkTfcWatchWindow INTEGER, + linkTfcAlarmThreshold INTEGER, + linkTfcAlarm AlarmStatus, + linkTfcRowStatus RowStatus + } + + linkTfcAction OBJECT-TYPE + SYNTAX INTEGER { + notActive (0), + reset (1) + } + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "reset: to clear the forced switch generated by Trasmission Fail + Check algorithm (only if 1+1 configuration and ISO system)." + ::= {linkTfcEntry 1} + + linkTfcControl OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "It enables the Tx switch from remote equipment (only if 1+1 + configuration and ISO system)." + DEFVAL {disable} + ::= {linkTfcEntry 2} + + linkTfcWatchWindow OBJECT-TYPE + SYNTAX INTEGER (1..300) + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "Watch Window (in seconds) related to Trasmission Fail Check + algorithm (only if 1+1 configuration and ISO system)." + DEFVAL { 60 } + ::= {linkTfcEntry 3} + + linkTfcAlarmThreshold OBJECT-TYPE + SYNTAX INTEGER (1..60) + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "Alarm Threshold (number of seconds with both remote RX in fail) + related to Trasmission Fail Check algorithm (only if 1+1 + configuration and ISO system)." + DEFVAL { 10 } + ::= {linkTfcEntry 4} + + linkTfcAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Transmission switch alarm generated by Trasmission Fail Check + algorithm (only if 1+1 configuration and ISO system)." + ::= {linkTfcEntry 5} + + linkTfcRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "Status of this conceptual row in linkTfcTable." + ::= {linkTfcEntry 6} + +-- +------- End of linkTfcTable + +------- Begin of linkMaintTable +-- + linkMaintTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkMaintEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with commands for maintenance of radio link. + Objects in this table is not persistent. An Instance of this + table is created on creation of linkStatusEntry" + ::= {radioSystem 19} + + linkMaintEntry OBJECT-TYPE + SYNTAX LinkMaintEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Radio link maintenance entry." + INDEX {linkIndex, + linkPolIndex} + ::= {linkMaintTable 1} + + LinkMaintEntry ::= + SEQUENCE { + linkBerStart INTEGER, + linkBaseBandLom INTEGER, + linkFadeMarginMeasure INTEGER, + linkXpicControlProcedureReset INTEGER + } + + linkBerStart OBJECT-TYPE + SYNTAX INTEGER { + restart (1), + stop (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Stop, Start (resetting errors and counters) the pattern. + This item is linked to a manual operation (ManOpRecord) instance." + DEFVAL {stop} + ::= {linkMaintEntry 1} + + linkBaseBandLom OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "It is used to enable the IP packet forwarding towards modems. + This item is linked to a manual operation (ManOpRecord) instance." + DEFVAL {disable} + ::= {linkMaintEntry 2} + + linkFadeMarginMeasure OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Set by manager to start/stop fade margin measure. + This item is linked to a manual operation (ManOpRecord) instance. + This object is deprecated and replaced by fadeMarginMeasure. + " + DEFVAL { disable } + ::= {linkMaintEntry 3} + + linkXpicControlProcedureReset OBJECT-TYPE + SYNTAX INTEGER { + notActive (0), + reset (1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set by manager to reset the XPIC control procedure after a + blocking action." + DEFVAL {notActive} + ::= {linkMaintEntry 4} + +-- +------- End of linkMaintTable + +------- Begin of linkBerTable +-- + linkBerTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkBerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with Command to estimate BER of radio equipment. + Every objects in this table is not persistent. An Instance of this + table is created on creation of linkStatusEntry" + ::= {radioSystem 20} + + linkBerEntry OBJECT-TYPE + SYNTAX LinkBerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Radio equipment BER estimate record." + INDEX {linkIndex, + linkPolIndex} + ::= {linkBerTable 1} + + LinkBerEntry ::= + SEQUENCE { + linkBerErrorCounterH Counter32, + linkBerErrorCounterL Counter32, + linkBerDataCounterH Counter32, + linkBerDataCounterL Counter32, + linkBerSyncLossAlarm AlarmStatus, + linkBerSyncLossAlarmCounter Integer32, + linkBerElapsedTime Integer32 + } + + linkBerErrorCounterH OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High 32 bit part of the 64 bit error counter. Bit 32-63." + ::= {linkBerEntry 1} + + linkBerErrorCounterL OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low 32 bit part of the 64 bit error counter. Bit 0-31." + ::= {linkBerEntry 2} + + linkBerDataCounterH OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High 32 bit part of the 64 bit data counter. Bit 32-63." + ::= {linkBerEntry 3} + + linkBerDataCounterL OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low 32 bit part of the 64 bit data counter. Bit 0-31." + ::= {linkBerEntry 4} + + linkBerSyncLossAlarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BER sync loss alarm." + ::= {linkBerEntry 5} + + linkBerSyncLossAlarmCounter OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BER sync loss events counter." + ::= {linkBerEntry 6} + + linkBerElapsedTime OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BER measure elapsed time." + ::= {linkBerEntry 7} + +-- +------- End of linkBerTable + +------- Begin of linkAcmTable +-- + linkAcmTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkAcmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with link records." + ::= {radioSystem 21} + + linkAcmEntry OBJECT-TYPE + SYNTAX LinkAcmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ACM entries." + INDEX {linkIndex, linkPolIndex, linkAcmProfileId} + ::= {linkAcmTable 1} + + LinkAcmEntry ::= + SEQUENCE { + linkAcmProfileId Integer32, + linkAcmProfileModulation BitsPerSymbol, + linkAcmProfileCode INTEGER, + linkAcmProfileCapacity Integer32, + linkAcmProfileLabel DisplayString, + linkAcmMaxTDMCapacity Integer32, + linkAcmPowerScaling Integer32, + linkAcmProfileEnable INTEGER, + linkAcmDownshiftThreshold Integer32, + linkAcmUpshiftThreshold Integer32, + linkAcmActiveProfile INTEGER, + linkAcmTDMCapacity Integer32, + linkAcmETHCapacity Integer32, + linkAcmAtpcRxPowerScaling Integer32, + linkAcmPowerRange Integer32 + } + + linkAcmProfileId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the profile number for the radio selected + by the object linkAcmId." + ::= {linkAcmEntry 1} + + linkAcmProfileModulation OBJECT-TYPE + SYNTAX BitsPerSymbol + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the modulation of the profile." + ::= {linkAcmEntry 2} + + linkAcmProfileCode OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + strong (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the type of codificator of the profile." + ::= {linkAcmEntry 3} + + linkAcmProfileCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to contain total capacity of profile + (in kbits/sec)." + ::= {linkAcmEntry 4} + + linkAcmProfileLabel OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ASCII string used to assign a name to profile." + ::= {linkAcmEntry 5} + + linkAcmProfileEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object is used to contain if the use of this profile is + enabled or disabled" + DEFVAL {enable} + ::= {linkAcmEntry 6} + + linkAcmMaxTDMCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "This object reports the maximum capacity that can + be assigned to the TDM traffic. + The capacity is specified in number of E1 (2Mbit/s). + + This object has been superseded by linkE1vsSTM1CapacityTable. + " + DEFVAL {0} + ::= {linkAcmEntry 7} + + linkAcmPowerScaling OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "This object contains the difference (in eighth of dB) between the + TX power at this profile modulation and the TX power at the + reference modulation. The power scaling value is achieved from the + table linkPtxProfileTable. + This object is deprecated: see combinedRadioPowerScalingTable." + ::= {linkAcmEntry 8} + + linkAcmDownshiftThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object is used to contain the downshift threshold in dB/10." + ::= {linkAcmEntry 9} + + linkAcmUpshiftThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object is used to contain the upshift threshold in dB/10." + ::= {linkAcmEntry 10} + + linkAcmActiveProfile OBJECT-TYPE + SYNTAX INTEGER { + cleared (1), + activeRx (2), + activeTx (3), + activeBoth (4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to contain the active status of this profile. + The value of the object is related to linkAcmRxProfile + and linkAcmTxProfile of the LinkStatusEntry." + DEFVAL {cleared} + ::= {linkAcmEntry 11} + + linkAcmTDMCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports current TDM capacity (in kbits/sec) + of the profile." + ::= {linkAcmEntry 12} + + linkAcmETHCapacity OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports current ETH capacity (in Kbits/sec) of + the profile." + ::= {linkAcmEntry 13} + + linkAcmAtpcRxPowerScaling OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "This object contains the difference (in eighth of dB) between the + ATPC RX level thresholds at this profile modulation and the ATPC + RX level thresholds at the upper modulation. + This object is deprecated: see combinedRadioPowerScalingTable." + ::= {linkAcmEntry 14} + + linkAcmPowerRange OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "This object contains (in dB) the current value of ATPC range. + This object is deprecated: see combinedRadioPowerScalingTable." + ::= {linkAcmEntry 15} + +-- +------- End of linkAcmTable + +------- Begin of linkProTable +-- + linkProTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkProEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "A list of protection link entries. + + This table was deprecated and replaced by linkProV2Table. + It is a view of the rows of the linkProV2Table with the same + linkIndex and linkPolIndex equal to 1, in order to ensure + compatibility with old SNMP managers + " + ::= {radioSystem 22} + + linkProEntry OBJECT-TYPE + SYNTAX LinkProEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An entry containing management information applicable to a + protected link. + " + INDEX {linkIndex} + ::= {linkProTable 1} + + LinkProEntry ::= + SEQUENCE { + linkProProtectionTxChIdx Integer32, + linkProProtectionRxChIdx Integer32, + linkProTxWtrTime INTEGER, + linkProRxWtrTime INTEGER, + linkProTxSwitchedChIdx Integer32, + linkProRxSwitchedChIdx Integer32, + linkProTxRevertive INTEGER, + linkProRxRevertive INTEGER, + linkProExtraTraffic INTEGER, + linkProRowStatus RowStatus + } + + linkProProtectionTxChIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "This object identifies the tx protection channel + of a protected link. This object is not applicable + in case of not-revertive protection. For N+1 links + a value different from zero must be set. + " + DEFVAL {0} + ::= {linkProEntry 1} + + linkProProtectionRxChIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "This object identifies the rx protection channel + of a protected link. This object is not applicable + in case of not-revertive protection. For N+1 links + a value different from zero must be set. + " + DEFVAL {0} + ::= {linkProEntry 2} + + linkProTxWtrTime OBJECT-TYPE + SYNTAX INTEGER (0..12) + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "It defines the Wait Time (in minutes) to Restore in transmission + when revertive protection is enabled. Zero value means no switch. + If switch is not supported or protection is not revertive, + a value different from zero cannot be set. + " + DEFVAL {0} + ::= {linkProEntry 3} + + linkProRxWtrTime OBJECT-TYPE + SYNTAX INTEGER (0..12) + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "It defines the Wait Time (in minutes) to Restore in reception when + revertive protection is enabled. Zero value means no switch. + If switch is not supported or protection is not revertive, + a value different from zero cannot be set. + " + DEFVAL {0} + ::= {linkProEntry 4} + + linkProTxSwitchedChIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "This object reports the index of tx channel switched to protection. + This object is applicable only for N+1 protection schema. + " + DEFVAL {0} + ::= {linkProEntry 5} + + linkProRxSwitchedChIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "This object reports the index of rx channel switched to protection. + This object is applicable only for N+1 protection schema. + " + DEFVAL {0} + ::= {linkProEntry 6} + + linkProTxRevertive OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "It defines if tx protection is revertive or not revertive. + In case of N+1 protection, protection is always revertive. + " + DEFVAL {disable} + ::= {linkProEntry 7} + + linkProRxRevertive OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "It defines if rx protection is revertive or not revertive. + In case of N+1 protection, protection is always revertive. + " + DEFVAL {disable} + ::= {linkProEntry 8} + + linkProExtraTraffic OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "This object enables or disables the transfer of extra traffic + on the protection channel in a N+1 link. This object must be + set to disabled in case of architectures different for N+1. + " + DEFVAL {disable} + ::= {linkProEntry 9} + + linkProRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "Status of this conceptual row in linkProTable. + " + ::= {linkProEntry 10} + +-- +------- End of linkProTable + +------- Begin of linkProMaintTable +-- + linkProMaintTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkProMaintEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "A list of maintenance commands for protected links. + A row in this table is added on creation of a row + in linkProTable. + + This table was deprecated and replaced by linkProMaintV2Table. + It is a view of the rows of the linkProMaintV2Table with the same + linkIndex and linkPolIndex equal to 1, in order to ensure + compatibility with old SNMP managers + " + ::= {radioSystem 23} + + linkProMaintEntry OBJECT-TYPE + SYNTAX LinkProMaintEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An entry containing maintenance commands applicable to a + protected link. + " + INDEX {linkIndex} + ::= {linkProMaintTable 1} + + LinkProMaintEntry ::= + SEQUENCE { + linkProMaintTxLockout INTEGER, + linkProMaintRxLockout INTEGER, + linkProMaintTxForced Integer32, + linkProMaintRxForced Integer32, + linkProMaintTxWtrReset INTEGER, + linkProMaintRxWtrReset INTEGER + } + + linkProMaintTxLockout OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Command to enable/disable tx lockout. This object + is applicable only in case of N+1 protections. + " + DEFVAL {disable} + ::= {linkProMaintEntry 1} + + linkProMaintRxLockout OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Command to enable/disable rx lockout. This object + is applicable only in case of N+1 protections. + " + DEFVAL {disable} + ::= {linkProMaintEntry 2} + + linkProMaintTxForced OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Command to force switch to a given + transmission channel. Zero value means no + switch. + " + DEFVAL {0} + ::= {linkProMaintEntry 3} + + linkProMaintRxForced OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Command to force switch to a given + receiving channel. Zero value means no + switch. + " + DEFVAL {0} + ::= {linkProMaintEntry 4} + + linkProMaintTxWtrReset OBJECT-TYPE + SYNTAX INTEGER { + notActive (1), + on (2) + } + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Clear wait time to restore making the revertive + path immediately available. + " + DEFVAL {notActive} + ::= {linkProMaintEntry 5} + + linkProMaintRxWtrReset OBJECT-TYPE + SYNTAX INTEGER { + notActive (1), + on (2) + } + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Clear wait time to restore making the revertive + path immediately available. + " + DEFVAL {notActive} + ::= {linkProMaintEntry 6} + + +-- +------- End of linkProMaintTable + +------- Begin of linkCapabilitiesTable +-- + linkCapabilitiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkCapabilitiesEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "Table with RadioCapabilities entries: there is an entry for each + linkTable row. + In 1+1 HS and XPIC radio links, this table contains only values + supported by both radios. + In 1+1 FD radio link, managers have to know the capabilities + of each channel. As such, this table is declared deprecated and + replaced by combinedRadioCapabilitiesTable." + ::= {radioSystem 24} + + linkCapabilitiesEntry OBJECT-TYPE + SYNTAX LinkCapabilitiesEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "LinkCapabilities entry." + INDEX {linkIndex} + ::= {linkCapabilitiesTable 1} + + LinkCapabilitiesEntry ::= + SEQUENCE { + linkCapabilitiesCapability RadioCapability, + linkCapabilitiesTxMinFrequency Integer32, + linkCapabilitiesTxMaxFrequency Integer32, + linkCapabilitiesStepFrequency Integer32, + linkCapabilitiesMinPtxNominalValue Integer32, + linkCapabilitiesMaxPtxNominalValue Integer32, + linkCapabilitiesExtendedMinPwr Integer32 + } + + linkCapabilitiesCapability OBJECT-TYPE + SYNTAX RadioCapability + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Bit map to describe the radio features." + ::= {linkCapabilitiesEntry 1} + + linkCapabilitiesTxMinFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Minimum of available channel frequency in KHz." + ::= {linkCapabilitiesEntry 2} + + linkCapabilitiesTxMaxFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Maximum of available channel frequency in KHz." + ::= {linkCapabilitiesEntry 3} + + linkCapabilitiesStepFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Minimum frequency step in KHz." + ::= {linkCapabilitiesEntry 4} + + linkCapabilitiesMinPtxNominalValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Minimum nominal Ptx in dBm." + ::= {linkCapabilitiesEntry 5} + + linkCapabilitiesMaxPtxNominalValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Maximum nominal Ptx in dBm." + ::= {linkCapabilitiesEntry 6} + + linkCapabilitiesExtendedMinPwr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Minimum extended Ptx power for fade margin." + ::= {linkCapabilitiesEntry 7} +-- +------- End of linkCapabilitiesTable + +------- Begin of linkFrequencyTable +-- + linkFrequencyTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkFreqEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "Availables channels for selected channel spacing and modulation + In 1+1 HS and XPIC radio links, this table contains only values + supported by both radios. + In 1+1 FD radio link, managers have to know the allowable + frequencies of each channel. As such, this table is declared + deprecated and replaced by combinedRadioFrequencyTable." + ::= {radioSystem 25} + + linkFreqTabEntry OBJECT-TYPE + SYNTAX LinkFreqEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "LinkFreqTab record." + INDEX {linkIndex, linkFreqChannelId} + ::= {linkFrequencyTable 1} + + LinkFreqEntry ::= + SEQUENCE { + linkFreqChannelId Integer32, + linkFreqChannelNum Integer32, + linkFreqValue Integer32 + } + + linkFreqChannelId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Index of the table" + ::= {linkFreqTabEntry 1} + + linkFreqChannelNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Available channel number." + ::= {linkFreqTabEntry 2} + + linkFreqValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Frequency related to linkFreqChannelNum." + ::= {linkFreqTabEntry 3} +-- +------- End of linkFrequencyTable + +------- Begin of linkDuplexFrequencyTable +-- + linkDuplexFrequencyTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkDuplexFreqEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "Table with available duplex frequencies. Duplex frequency is + the absolute value of difference between RX and TX frequency. + In 1+1 HS and XPIC radio links, this table contains only values + supported by both radios. + In 1+1 FD radio link, managers have to know the allowable + duplex frequencies of each channel. As such, this table is declared + deprecated and replaced by combinedRadioDuplexFrequencyTable." + ::= {radioSystem 26} + + linkDuplexFreqEntry OBJECT-TYPE + SYNTAX LinkDuplexFreqEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "Duplex Frequency entry. For each available duplex frequency" + INDEX {linkIndex, linkDuplexFreqId} + ::= {linkDuplexFrequencyTable 1} + + LinkDuplexFreqEntry ::= + SEQUENCE { + linkDuplexFreqId Integer32, + linkDuplexFreqValue Integer32 + } + + linkDuplexFreqId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Index of the table." + ::= {linkDuplexFreqEntry 1} + + linkDuplexFreqValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Duplex frequency in KHz." + ::= {linkDuplexFreqEntry 2} +-- +------- End of linkDuplexFrequencyTable + +------- Begin of linkModulationTable +-- + linkModulationTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkModulationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "List of modulation related to channel spacing. + In 1+1 HS and XPIC radio links, this table contains only values + supported by both radios. + " + ::= {radioSystem 27} + + linkModulationEntry OBJECT-TYPE + SYNTAX LinkModulationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "linkModulation record." + INDEX {linkIndex, linkChannelSpacing} + ::= {linkModulationTable 1} + + LinkModulationEntry ::= + SEQUENCE { + linkChannelSpacing ChannelSpacing, + linkModulationMap ModulationMap, + linkRefModulationMap ModulationMap + } + + linkChannelSpacing OBJECT-TYPE + SYNTAX ChannelSpacing + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the channel spacing." + ::= {linkModulationEntry 1} + + linkModulationMap OBJECT-TYPE + SYNTAX ModulationMap + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of modulation in the linkChanSpacing" + ::= {linkModulationEntry 2} + + linkRefModulationMap OBJECT-TYPE + SYNTAX ModulationMap + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of modulations that can be selected as reference + in the linkChanSpacingId" + ::= {linkModulationEntry 3} +-- +------- End of linkModulationTable + +------- Begin of linkChCapabilitiesTable +-- + combinedRadioCapabilitiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF CombinedRadioCapabilitiesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with RadioCapabilities entries: there is an entry for each + radioSettingTable row. + In 1+1 HS and XPIC radio links, this table contains only values + supported by both radios belonging to the link. + In 1+1 FD radio link, managers have to know the allowable + duplex frequencies of each channel. As such, this table is declared + deprecated and replaced by combinedRadioCapabilitiesTable." + ::= {radioSystem 28} + + combinedRadioCapabilitiesEntry OBJECT-TYPE + SYNTAX CombinedRadioCapabilitiesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "combinedRadioCapabilities entry." + INDEX {radioSettingsIndex} + ::= {combinedRadioCapabilitiesTable 1} + + CombinedRadioCapabilitiesEntry ::= + SEQUENCE { + combinedRadioCapabilitiesCapability RadioCapability, + combinedRadioCapabilitiesTxMinFrequency Integer32, + combinedRadioCapabilitiesTxMaxFrequency Integer32, + combinedRadioCapabilitiesStepFrequency Integer32, + combinedRadioCapabilitiesMinPtxNominalValue Integer32, + combinedRadioCapabilitiesMaxPtxNominalValue Integer32, + combinedRadioCapabilitiesExtendedMinPwr Integer32 + } + + combinedRadioCapabilitiesCapability OBJECT-TYPE + SYNTAX RadioCapability + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bit map to describe the radio features." + ::= {combinedRadioCapabilitiesEntry 1} + + combinedRadioCapabilitiesTxMinFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum of available channel frequency in KHz." + ::= {combinedRadioCapabilitiesEntry 2} + + combinedRadioCapabilitiesTxMaxFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum of available channel frequency in KHz." + ::= {combinedRadioCapabilitiesEntry 3} + + combinedRadioCapabilitiesStepFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum frequency step in KHz." + ::= {combinedRadioCapabilitiesEntry 4} + + combinedRadioCapabilitiesMinPtxNominalValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum nominal Ptx in dBm." + ::= {combinedRadioCapabilitiesEntry 5} + + combinedRadioCapabilitiesMaxPtxNominalValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum nominal Ptx in dBm." + ::= {combinedRadioCapabilitiesEntry 6} + + combinedRadioCapabilitiesExtendedMinPwr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum extended Ptx power for fade margin." + ::= {combinedRadioCapabilitiesEntry 7} +-- +------- End of combinedRadioCapabilitiesTable + +------- Begin of combinedRadioFrequencyTable +-- + combinedRadioFrequencyTable OBJECT-TYPE + SYNTAX SEQUENCE OF CombinedRadioFreqEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Availables channels for selected channel spacing and modulation + In 1+1 HS and XPIC radio links, this table contains only values + supported by both radios." + ::= {radioSystem 29} + + combinedRadioFreqTabEntry OBJECT-TYPE + SYNTAX CombinedRadioFreqEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "combinedRadioFreqTab record." + INDEX {radioSettingsIndex, combinedRadioFreqChannelId} + ::= {combinedRadioFrequencyTable 1} + + CombinedRadioFreqEntry ::= + SEQUENCE { + combinedRadioFreqChannelId Integer32, + combinedRadioFreqChannelNum Integer32, + combinedRadioFreqValue Integer32 + } + + combinedRadioFreqChannelId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index of the table" + ::= {combinedRadioFreqTabEntry 1} + + combinedRadioFreqChannelNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Available channel number." + ::= {combinedRadioFreqTabEntry 2} + + combinedRadioFreqValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency related to combinedRadioFreqChannelNum." + ::= {combinedRadioFreqTabEntry 3} +-- +------- End of combinedRadioFrequencyTable + +------- Begin of combinedRadioDuplexFrequencyTable +-- + combinedRadioDuplexFrequencyTable OBJECT-TYPE + SYNTAX SEQUENCE OF CombinedRadioDuplexFreqEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with available duplex frequencies. Duplex frequency is + the absolute value of difference between RX and TX frequency. + In 1+1 HS and XPIC radio links, this table contains only values + supported by both radios." + ::= {radioSystem 30} + + combinedRadioDuplexFreqEntry OBJECT-TYPE + SYNTAX CombinedRadioDuplexFreqEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Duplex Frequency entry. There is an entry for each available + duplex frequency." + INDEX {radioSettingsIndex, combinedRadioDuplexFreqId} + ::= {combinedRadioDuplexFrequencyTable 1} + + CombinedRadioDuplexFreqEntry ::= + SEQUENCE { + combinedRadioDuplexFreqId Integer32, + combinedRadioDuplexFreqValue Integer32 + } + + combinedRadioDuplexFreqId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index of the table." + ::= {combinedRadioDuplexFreqEntry 1} + + combinedRadioDuplexFreqValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Duplex frequency in KHz." + ::= {combinedRadioDuplexFreqEntry 2} +-- +------- End of combinedRadioDuplexFrequencyTable + +------- Begin of combinedRadioPowerScalingTable +-- + combinedRadioPowerScalingTable OBJECT-TYPE + SYNTAX SEQUENCE OF CombinedRadioPowerScalingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "List of modulation related to channel spacing. + In 1+1 HS and XPIC radio links, this table contains only values + supported by both radios." + ::= {radioSystem 31} + + combinedRadioPowerScalingEntry OBJECT-TYPE + SYNTAX CombinedRadioPowerScalingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "radioPowerScaling record." + INDEX {radioSettingsIndex, linkAcmProfileId} + ::= {combinedRadioPowerScalingTable 1} + + CombinedRadioPowerScalingEntry ::= + SEQUENCE { + combinedRadioPowerScaling Integer32, + combinedRadioAtpcRxPowerScaling Integer32, + combinedRadioPowerRange Integer32 + } + + combinedRadioPowerScaling OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the difference (in eighth of dB) between the + TX power at this profile modulation and the TX power at the + reference modulation. The power scaling value is achieved from the + table linkPtxProfileTable." + ::= {combinedRadioPowerScalingEntry 1} + + combinedRadioAtpcRxPowerScaling OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the difference (in eighth of dB) between the + ATPC RX level thresholds at this profile modulation and the ATPC + RX level thresholds at the upper modulation." + ::= {combinedRadioPowerScalingEntry 2} + + combinedRadioPowerRange OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains (in dB) the current value of ATPC range." + ::= {combinedRadioPowerScalingEntry 3} +-- +------- End of radioPowerScalingTable + +------- Begin of stm1BulkSettingsTable +-- + stm1BulkMappingTable OBJECT-TYPE + SYNTAX SEQUENCE OF Stm1BulkMappingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with entries containing stm-1 bulk transport parameters + for a particular link. + For each link are present as many rows as the STM-1 that the link + can carry in bulk mode. + " + ::= {radioSystem 32} + + stm1BulkMappingEntry OBJECT-TYPE + SYNTAX Stm1BulkMappingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An row in stm1BulkSettingsTable. + " + INDEX {linkIndex, stm1BulkPolIndex, stm1BulkChanIndex} + ::= {stm1BulkMappingTable 1} + + Stm1BulkMappingEntry ::= + SEQUENCE { + stm1BulkPolIndex Integer32, + stm1BulkChanIndex Integer32, + stm1BulkChannel Stm1IndexOrZero + } + + stm1BulkPolIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Polarization index. + " + ::= {stm1BulkMappingEntry 1} + + stm1BulkChanIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "STM-1 channel index. + The range of this object is from 1 to N, where N is the number + of STM-1 that a link can carry in bulk mode. + " + ::= {stm1BulkMappingEntry 2} + + stm1BulkChannel OBJECT-TYPE + SYNTAX Stm1IndexOrZero + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Index of the stm-1 in stm1Table. + The SNMP agent will accept only index of a STM-1 present in + stm1Table with stm1Structure set to opaque(4). + " + DEFVAL {0} + ::= {stm1BulkMappingEntry 3} + +-- +------- End of stm1BulkSettingsTable + +------- Begin of linkE1vsSTM1CapacityTable +-- + + linkE1vsSTM1CapacityTable OBJECT-TYPE + SYNTAX SEQUENCE OF LinkE1vsSTM1CapacityEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table with entries containing the E1 cpacity according to the + tributaries STM-1 configured to be carried in bulk mode. + " + ::= {radioSystem 33} + + linkE1vsSTM1CapacityEntry OBJECT-TYPE + SYNTAX LinkE1vsSTM1CapacityEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An row in linkE1vsSTM1CapacityTable. + " + INDEX {linkIndex, linkAcmProfileId, linkE1vsSTM1CapacityStm1} + ::= {linkE1vsSTM1CapacityTable 1} + + LinkE1vsSTM1CapacityEntry ::= + SEQUENCE { + linkE1vsSTM1CapacityStm1 Integer32, + linkE1vsSTM1CapacityE1 Integer32 + } + + linkE1vsSTM1CapacityStm1 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Number of tributaries STM-1 configured to be transported in + bulk mode. + " + ::= {linkE1vsSTM1CapacityEntry 1 } + + linkE1vsSTM1CapacityE1 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of E1 that can be carried by this profile according to the + the tributaries STM-1 carried in bulk mode. + " + ::= {linkE1vsSTM1CapacityEntry 2} + +-- +------- End of linkE1vsSTM1CapacityTable + +------- Begin of linkTfcV2Table +-- + linkTfcV2Table OBJECT-TYPE + SYNTAX SEQUENCE OF LinkTfcV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Transmitter Fail Check feature. In 1+1 HS configuration, the + radio terminal that doesn't receive signals on both receivers, + requests the remote transmitter switch." + ::= {radioSystem 34} + + linkTfcV2Entry OBJECT-TYPE + SYNTAX LinkTfcV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Radio link TFC entry." + INDEX {linkIndex, linkPolIndex} + ::= {linkTfcV2Table 1} + + LinkTfcV2Entry ::= + SEQUENCE { + linkTfcV2Action INTEGER, + linkTfcV2Control INTEGER, + linkTfcV2WatchWindow INTEGER, + linkTfcV2AlarmThreshold INTEGER, + linkTfcV2Alarm AlarmStatus, + linkTfcV2RowStatus RowStatus + } + + linkTfcV2Action OBJECT-TYPE + SYNTAX INTEGER { + notActive (0), + reset (1) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "reset: to clear the forced switch generated by Trasmission Fail + Check algorithm (only if 1+1 configuration and ISO system)." + ::= {linkTfcV2Entry 1} + + linkTfcV2Control OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "It enables the Tx switch from remote equipment (only if 1+1 + configuration and ISO system)." + DEFVAL {disable} + ::= {linkTfcV2Entry 2} + + linkTfcV2WatchWindow OBJECT-TYPE + SYNTAX INTEGER (1..300) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Watch Window (in seconds) related to Trasmission Fail Check + algorithm (only if 1+1 configuration and ISO system)." + DEFVAL { 60 } + ::= {linkTfcV2Entry 3} + + linkTfcV2AlarmThreshold OBJECT-TYPE + SYNTAX INTEGER (1..60) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Alarm Threshold (number of seconds with both remote RX in fail) + related to Trasmission Fail Check algorithm (only if 1+1 + configuration and ISO system)." + DEFVAL { 10 } + ::= {linkTfcV2Entry 4} + + linkTfcV2Alarm OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Transmission switch alarm generated by Trasmission Fail Check + algorithm (only if 1+1 configuration and ISO system)." + ::= {linkTfcV2Entry 5} + + linkTfcV2RowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this conceptual row in linkTfcV2Table." + ::= {linkTfcV2Entry 6} + +-- +------- End of linkTfcV2Table + +------- Begin of linkProV2Table +-- + linkProV2Table OBJECT-TYPE + SYNTAX SEQUENCE OF LinkProV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of protection link entries. + " + ::= {radioSystem 35} + + linkProV2Entry OBJECT-TYPE + SYNTAX LinkProV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing management information applicable to a + protected link. + " + INDEX {linkIndex, linkPolIndex} + ::= {linkProV2Table 1} + + LinkProV2Entry ::= + SEQUENCE { + linkProV2ProtectionTxChIdx Integer32, + linkProV2ProtectionRxChIdx Integer32, + linkProV2TxWtrTime INTEGER, + linkProV2RxWtrTime INTEGER, + linkProV2TxSwitchedChIdx Integer32, + linkProV2RxSwitchedChIdx Integer32, + linkProV2TxRevertive INTEGER, + linkProV2RxRevertive INTEGER, + linkProV2ExtraTraffic INTEGER, + linkProV2RowStatus RowStatus + } + + linkProV2ProtectionTxChIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object identifies the tx protection channel + of a protected link. This object is not applicable + in case of not-revertive protection. For N+1 links + a value different from zero must be set. + " + DEFVAL {0} + ::= {linkProV2Entry 1} + + linkProV2ProtectionRxChIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object identifies the rx protection channel + of a protected link. This object is not applicable + in case of not-revertive protection. For N+1 links + a value different from zero must be set. + " + DEFVAL {0} + ::= {linkProV2Entry 2} + + linkProV2TxWtrTime OBJECT-TYPE + SYNTAX INTEGER (0..12) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "It defines the Wait Time (in minutes) to Restore in transmission + when revertive protection is enabled. Zero value means no switch. + If switch is not supported or protection is not revertive, + a value different from zero cannot be set. + " + DEFVAL {0} + ::= {linkProV2Entry 3} + + linkProV2RxWtrTime OBJECT-TYPE + SYNTAX INTEGER (0..12) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "It defines the Wait Time (in minutes) to Restore in reception when + revertive protection is enabled. Zero value means no switch. + If switch is not supported or protection is not revertive, + a value different from zero cannot be set. + " + DEFVAL {0} + ::= {linkProV2Entry 4} + + linkProV2TxSwitchedChIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports the index of tx channel switched to protection. + This object is applicable only for N+1 protection schema. + " + DEFVAL {0} + ::= {linkProV2Entry 5} + + linkProV2RxSwitchedChIdx OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports the index of rx channel switched to protection. + This object is applicable only for N+1 protection schema. + " + DEFVAL {0} + ::= {linkProV2Entry 6} + + linkProV2TxRevertive OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "It defines if tx protection is revertive or not revertive. + In case of N+1 protection, protection is always revertive. + " + DEFVAL {disable} + ::= {linkProV2Entry 7} + + linkProV2RxRevertive OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "It defines if rx protection is revertive or not revertive. + In case of N+1 protection, protection is always revertive. + " + DEFVAL {disable} + ::= {linkProV2Entry 8} + + linkProV2ExtraTraffic OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object enables or disables the transfer of extra traffic + on the protection channel in a N+1 link. This object must be + set to disabled in case of architectures different for N+1. + " + DEFVAL {disable} + ::= {linkProV2Entry 9} + + linkProV2RowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Status of this conceptual row in linkProV2Table. + " + ::= {linkProV2Entry 10} + +-- +------- End of linkProV2Table + +------- Begin of linkProMaintV2Table +-- + linkProMaintV2Table OBJECT-TYPE + SYNTAX SEQUENCE OF LinkProMaintV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of maintenance commands for protected links. + A row in this table is added on creation of a row + in linkProV2Table. + " + ::= {radioSystem 36} + + linkProMaintV2Entry OBJECT-TYPE + SYNTAX LinkProMaintV2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing maintenance commands applicable to a + protected link. + " + INDEX {linkIndex, linkPolIndex} + ::= {linkProMaintV2Table 1} + + LinkProMaintV2Entry ::= + SEQUENCE { + linkProMaintV2TxLockout INTEGER, + linkProMaintV2RxLockout INTEGER, + linkProMaintV2TxForced Integer32, + linkProMaintV2RxForced Integer32, + linkProMaintV2TxWtrReset INTEGER, + linkProMaintV2RxWtrReset INTEGER + } + + linkProMaintV2TxLockout OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Command to enable/disable tx lockout. This object + is applicable only in case of N+1 protections. + " + DEFVAL {disable} + ::= {linkProMaintV2Entry 1} + + linkProMaintV2RxLockout OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Command to enable/disable rx lockout. This object + is applicable only in case of N+1 protections. + " + DEFVAL {disable} + ::= {linkProMaintV2Entry 2} + + linkProMaintV2TxForced OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Command to force switch to a given + transmission channel. Zero value means no + switch. + " + DEFVAL {0} + ::= {linkProMaintV2Entry 3} + + linkProMaintV2RxForced OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Command to force switch to a given + receiving channel. Zero value means no + switch. + " + DEFVAL {0} + ::= {linkProMaintV2Entry 4} + + linkProMaintV2TxWtrReset OBJECT-TYPE + SYNTAX INTEGER { + notActive (1), + on (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear wait time to restore making the revertive + path immediately available. + " + DEFVAL {notActive} + ::= {linkProMaintV2Entry 5} + + linkProMaintV2RxWtrReset OBJECT-TYPE + SYNTAX INTEGER { + notActive (1), + on (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear wait time to restore making the revertive + path immediately available. + " + DEFVAL {notActive} + ::= {linkProMaintV2Entry 6} + +-- +------- End of linkProMaintV2Table + +------- Begin of sspTable +-- + sspTable OBJECT-TYPE + SYNTAX SEQUENCE OF SspEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of operative and administrative set of parameters. + This table holds three row for every link (and its polarizations) + configured in the NE: + 1) administative parameters of local NE + 2) operative parameters of local NE + 3) administative parameters of remote NE + " + ::= {radioSystem 37} + + sspEntry OBJECT-TYPE + SYNTAX SspEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing SSP relevant parameters. + " + INDEX {linkIndex, linkPolIndex, sspParameterType} + ::= {sspTable 1} + + SspEntry ::= + SEQUENCE { + sspParameterType INTEGER, + sspLinkBandwidth INTEGER, + sspLinkModulation INTEGER, + sspLinkAcmEngineEnable INTEGER, + sspLinkTxUpperProfile INTEGER, + sspLinkTxLowerProfile INTEGER, + sspLinkSynchSetupProtocolEnable INTEGER, + sspLinkProfilesSetSelection INTEGER, + sspTdmE1Channel Integer32, + sspTdmStm1Channel Integer32 + } + + sspParameterType OBJECT-TYPE + SYNTAX INTEGER { + localAdminStatus (1), + localOperStatus (2), + remoteAdminStatus (3) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object identifies what parameters are for. + " + ::= {sspEntry 1} + + sspLinkBandwidth OBJECT-TYPE + SYNTAX INTEGER { + sspBw3p5Mhz (0), + sspBw7MHz (1), + sspBw14MHz (2), + sspBw28MHz (3), + sspBw56MHz (4), + sspBw10MHz (5), + sspBw20MHz (6), + sspBw30MHz (7), + sspBw40MHz (8), + sspBw50MHz (9), + sspBw112Mhz (10), + sspBw250Mhz (11), + sspBw500Mhz (12), + sspBw750Mhz (13), + sspBw1Ghz (14), + sspBw60MHz (15), + sspBw80MHz (16) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link Bandwidth (channel spacing). + " + ::= {sspEntry 2} + + sspLinkModulation OBJECT-TYPE + SYNTAX INTEGER{ + sspModBPSK (1), + sspMod4QAM (2), + sspMod8PSK (3), + sspMod16QAM (4), + sspMod32QAM (5), + sspMod64QAM (6), + sspMod128QAM (7), + sspMod256QAM (8), + sspMod512QAM (9), + sspMod1024QAM (10), + sspMod2048QAM (11), + sspMod4096QAM (12) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link reference modulation. + " + ::= {sspEntry 3} + + sspLinkAcmEngineEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to enable/disable the ACM engine. + " + DEFVAL { disable } + ::= {sspEntry 4} + + sspLinkTxUpperProfile OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object (and linkTxLowerProfile object) is used to + restrict the TX profile range when ACM is enabled. + " + ::= {sspEntry 5} + + sspLinkTxLowerProfile OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object (and linkTxUpperProfile object) is used to + restrict the TX profile range when ACM is enabled. + " + ::= {sspEntry 6} + + sspLinkSynchSetupProtocolEnable OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronization Setup Protocol (SSP) control. + " + ::= {sspEntry 7} + + sspLinkProfilesSetSelection OBJECT-TYPE + SYNTAX INTEGER { + highThroughput (1), + highGain (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Selection of the working profile set between high gain + (max robustness) profile set and high throughput (max + capacity) profile set. The set of profiles high gain + features a greater robustness against to the set of + profiles high throughput. + For radio systems that do not have more sets of profiles, + this object becomes read only and its reading shows the + only one set of profiles supported. + " + ::= {sspEntry 8} + + sspTdmE1Channel OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of E1 channels. This object is used to define the capacity + of E1 tributaries assigned to a given radio link. The capacity is + changed in steps of E1 (2Mbit/s). + " + ::= {sspEntry 9} + + sspTdmStm1Channel OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of STM-1 channels transported in bulk mode. + " + ::= {sspEntry 10} + +-- +------- End of sspTable + +------- Begin of radioLoopCapabilityTable +-- + radioLoopCapabilityTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioLoopCapabilityEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table shows which group a radio loop belongs to. + Radios with the same group number (identifier) close loop + simultaneously. + " + ::= {radioSystem 38} + + radioLoopCapabilityEntry OBJECT-TYPE + SYNTAX RadioLoopCapabilityEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing a group identifier for each radio loop type. + " + INDEX {radioIndex} + ::= {radioLoopCapabilityTable 1} + + RadioLoopCapabilityEntry ::= + SEQUENCE { + radioLoopRfGroup Integer32, + radioLoopIqGroup Integer32, + radioLoopBaseBandGroup Integer32 + } + + radioLoopRfGroup OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The group to which the radio RF loop belong to. + " + ::= {radioLoopCapabilityEntry 1} + + + radioLoopIqGroup OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The group to which the radio IQ loop belong to. + " + ::= {radioLoopCapabilityEntry 2} + + radioLoopBaseBandGroup OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The group to which the radio base loop belong to. + " + ::= {radioLoopCapabilityEntry 3} + +-- +------- End of radioLoopCapabilityTable + +------- Begin of radioRxThresholdTable +-- + radioRxBerThresholdTable OBJECT-TYPE + SYNTAX SEQUENCE OF RadioRxBerThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table shows the nominal and measured values of RX power + at a bit error rate (BER) equal to 10e-6. + " + ::= {radioSystem 39} + + radioRxBerThresholdEntry OBJECT-TYPE + SYNTAX RadioRxBerThresholdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing the RX power thresholds. + " + INDEX {radioIndex} + ::= {radioRxBerThresholdTable 1} + + RadioRxBerThresholdEntry ::= + SEQUENCE { + radioRxBerThresholdStatus INTEGER, + radioNominalRxBerThreshold Integer32, + radioMeasuredRxBerThreshold Integer32 + } + + radioRxBerThresholdStatus OBJECT-TYPE + SYNTAX INTEGER { + nonValid (1), + valid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object shows whether the following objects are significant. + " + ::= {radioRxBerThresholdEntry 1} + + radioNominalRxBerThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The nominal value of RX power @ BER equal to 10e-6 + " + ::= {radioRxBerThresholdEntry 2} + + radioMeasuredRxBerThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured value of RX power @ BER equal to 10e-6. + " + ::= {radioRxBerThresholdEntry 3} + +-- +------- End of radioRxThresholdTable + + + radioRemDemodulatorFailAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioRemDemodulatorFailAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 50} + + radioRxActiveStatusTrapNotification OBJECT-TYPE + SYNTAX INTEGER { + trapDisable (1), + trapEnable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disables (statusTrapEnable or statusTrapDisable) the trap + generation on status change event for radioRxActivestatus" + DEFVAL{ trapEnable } + ::= {radioSystem 51} + + radioTxActiveStatusTrapNotification OBJECT-TYPE + SYNTAX INTEGER { + trapDisable (1), + trapEnable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the radioTxActivestatus and + enable/disable the trap generation on status change event." + DEFVAL{ trapEnable } + ::= {radioSystem 52} + + radioCableOpenAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioCableOpen + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 53} + + radioCableShortAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioCableShort + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 54} + + radioInvalidFrequencyAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioInvalidFrequencyAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 55} + + radioBaseBandRxAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioBaseBandRxAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 56} + + radioModulatorFailAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioModulatorFailAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 57} + + radioDemodulatorFailAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioDemodulatorFailAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 58} + + radioRxPowerLowAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioRxPowerLowAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 59} + + radioTxPowerLowAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioTxPowerLowAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 60} + + radioVcoFailAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioVcoFailAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 61} + + radioRxIFAgcAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioRxIFAgcAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 62} + + radioTxIFAgcAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioTxIFAgcAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 63} + + radioIduOduCommunicationAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the radioIduOduCommunicationAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 64} + + radioOduIduCommunicationAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the radioOduIduCommunicationAlarm + and enable/disable the trap generation on status change event." + DEFVAL {warningTrapEnable} + ::= {radioSystem 65} + + radioLocalOduAlarmSynthesisSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the radioLocalOduAlarmSynthesis + and enable/disable the trap generation on status change event." + DEFVAL {statusTrapDisable} + ::= {radioSystem 66} + + radioRemoteOduAlarmSynthesisSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the radioRemoteOduAlarmSynthesis + and enable/disable the trap generation on status change event." + DEFVAL {statusTrapDisable} + ::= {radioSystem 67} + + radioConfigMismatchAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the severity associated to the radioConfigMismatchAlarm + and enables/disables the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 68} + + radioPrxHysteresisValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the delta value associated to the radioPrx before + having a new trap generation (radioPtxChange TRAP). + The zero value is not allowed." + DEFVAL {3} + ::= {radioSystem 69} + + radioPtxHysteresisValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the delta value associated to the radioPtx before + having a new trap generation (radioPtxChange TRAP). + The zero value is not allowed." + DEFVAL {3} + ::= {radioSystem 70} + + radioPrxHysteresisValueTrapNotification OBJECT-TYPE + SYNTAX INTEGER { + trapDisable (1), + trapEnable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/disables the Rx change trap generation on status change + event." + DEFVAL {trapEnable} + ::= {radioSystem 71} + + radioPtxHysteresisValueTrapNotification OBJECT-TYPE + SYNTAX INTEGER { + trapDisable (1), + trapEnable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/disables the Tx change trap generation on status change + event." + DEFVAL {trapEnable} + ::= {radioSystem 72} + + radioRxQualityLowAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the radioRxQualityLowAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 73} + + radioRxQualityWarningAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the radioRxQualityWarningAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 74} + + linkReducedCapacityAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkReducedCapacityAlarm + and enable/disable the trap generation on status change event." + DEFVAL {warningTrapEnable} + ::= {radioSystem 75} + + linkLinkTelemetryFailAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkLinkTelemetryFailAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 76} + + linkIdMismatchAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkIdMismatchAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 77} + + linkRadioEocAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkRadioEocAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 78} + + linkSetupMismatchAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkSetupMismatchAlarm + and enable/disable the trap generation on status change event." + DEFVAL {warningTrapEnable} + ::= {radioSystem 79} + + linkRescueSetupAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkRescueSetupAlarm + and enable/disable the trap generation on status change event." + DEFVAL {criticalTrapEnable} + ::= {radioSystem 80} + + linkXpicProcedureBlockAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkXpicProcedureBlockAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 81} + + linkXpicRemTxOffAlarmAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkXpicRemTxOffAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 82} + + linkLocalIduAlarmSynthesis OBJECT-TYPE + SYNTAX AlarmStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synthesis of the local IDU alarms" + ::= {radioSystem 83} + + linkLocalIduAlarmSynthesisSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkLocalIduAlarmSynthesis + and enable/disable the trap generation on status change event." + DEFVAL{ statusTrapDisable } + ::= {radioSystem 84} + + linkRemoteIduAlarmSynthesisSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkLocalIduAlarmSynthesis + and enable/disable the trap generation on status change event." + DEFVAL{ statusTrapDisable } + ::= {radioSystem 85} + + linkTfcAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkTfcV2Alarm (linkTfcAlarm) + and enable/disable the trap generation on status change event." + DEFVAL { minorTrapEnable } + ::= {radioSystem 86} + + linkBerSyncLossAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkBerSyncLossAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 87} + + linkNotMatchingRadiosAlarmSeverityCode OBJECT-TYPE + SYNTAX AlarmSeverityCode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define the severity associated to the linkNotMatchingRadiosAlarm + and enable/disable the trap generation on status change event." + DEFVAL {majorTrapEnable} + ::= {radioSystem 88} + + channelSpacingSelection OBJECT-TYPE + SYNTAX BITS { + etsi (0), + fcc (1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "his object selects which channel spacings the radio link has to + support: + - etsi: Compliant with European Telecommunication Standards + Institute + - fcc: Compliant with Federal Communications Commission + " + DEFVAL { { etsi, fcc } } + ::= {radioSystem 89} + + fadeMarginMeasure OBJECT-TYPE + SYNTAX INTEGER { + disable (1), + enable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set by manager to start/stop fade margin measure. + This item is linked to a manual operation (ManOpRecord) instance." + DEFVAL { disable } + ::= {radioSystem 90} + + linkConfigurationInProgressTrapNotification OBJECT-TYPE + SYNTAX INTEGER { + trapDisable (1), + trapEnable (2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disables (statusTrapEnable or statusTrapDisable) the trap + generation on status change event for linkConfigurationInProgress" + DEFVAL{ trapEnable } + ::= {radioSystem 91} + +----------------------- +-- This MIB module generates the following TRAPs: +----------------------- + radioPrxChange NOTIFICATION-TYPE + OBJECTS {equipIpSnmpAgentAddress, radioIndex, radioSettingsLabel, radioPrx} + STATUS current + DESCRIPTION + "This event is generated when radioPrx is changed, in + modulus, more than radioPtxHysteresisValue from last TRAP. + The data passed with the event are: + 1) equipIpSnmpAgentAddress - agent IP address + 2) radioIndex - branch index + 3) radioName - user assinged name + 4) radioPrx - PRX value" + ::= { alarmTrap 8001 } + + radioPtxChange NOTIFICATION-TYPE + OBJECTS {equipIpSnmpAgentAddress, radioIndex, radioSettingsLabel, radioPtx} + STATUS current + DESCRIPTION + "This event is generated when radioPtx is changed, in + modulus, more than radioPtxHysteresisValue from last TRAP. + The data passed with the event are: + 1) equipIpSnmpAgentAddress - agent IP address + 2) radioIndex - branch index + 3) radioName - user assigned name + 4) radioPtx - PTX value" + ::= { alarmTrap 8002 } + +------ End group ----------------------------------------------------------------- + +---------------------------------- End ------------------------------------- + + +END + |