summaryrefslogtreecommitdiff
path: root/MIBS/volius/VOLIUS-OR-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/volius/VOLIUS-OR-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/volius/VOLIUS-OR-MIB')
-rw-r--r--MIBS/volius/VOLIUS-OR-MIB755
1 files changed, 755 insertions, 0 deletions
diff --git a/MIBS/volius/VOLIUS-OR-MIB b/MIBS/volius/VOLIUS-OR-MIB
new file mode 100644
index 0000000..c17cef3
--- /dev/null
+++ b/MIBS/volius/VOLIUS-OR-MIB
@@ -0,0 +1,755 @@
+
+VOLIUS-OR-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ NOTIFICATION-TYPE, OBJECT-TYPE, MODULE-IDENTITY,
+ enterprises, TimeTicks, Integer32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, TruthValue, MacAddress,
+ DateAndTime, DisplayString
+ FROM SNMPv2-TC
+ InetAddressIPv4
+ FROM INET-ADDRESS-MIB;
+
+vlsGlobalModule MODULE-IDENTITY
+ LAST-UPDATED "201105311534Z"
+ ORGANIZATION
+ "Volius"
+ CONTACT-INFO
+ ""
+ DESCRIPTION
+ "This MIB describes all SNMP-enabled hardware produced by Volius,
+ such as Fiber optical receivers, Erbium-doped fiber amplifiers,
+ Optical switches, CATV optical transmitters."
+
+ REVISION "201105311543Z"
+ DESCRIPTION
+ "Initial version"
+::= { volius 1 }
+
+
+VlsDb ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "This data type represents gain expressed in dB (no fractional part)."
+ SYNTAX Integer32
+
+
+VlsEvent ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ ""
+ SYNTAX INTEGER {
+ vlsEventBlinking (6),
+ vlsEventFirmwareUpload (7),
+ vlsEventStartUp (8),
+ vlsEventPowerSw1 (27),
+ vlsEventPowerSw2 (28)
+ }
+
+
+VlsInputSwitchMode ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ ""
+ SYNTAX INTEGER {
+ vlsForce1 (1),
+ vlsForce2 (2),
+ vlsPrefer1 (3),
+ vlsPrefer2 (4),
+ vlsAutoLatching (5)
+ }
+
+
+VlsKiloHertz ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "Data type representing frequency in units of kHz."
+ SYNTAX Integer32
+
+
+VlsMilliVolt ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ ""
+ SYNTAX Integer32
+
+
+VlsPowerSwitchMode ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ ""
+ SYNTAX INTEGER {
+ vlsForce1 (1),
+ vlsForce2 (2),
+ vlsAuto (3)
+ }
+
+
+VlsTenthCelsius ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-1"
+ STATUS current
+ DESCRIPTION
+ "This data type represents temperature values that are normally
+ expressed in degrees Celsius. Units are in tenths of a degree;
+ for example, -5.1 degrees will be represented as -51."
+ SYNTAX Integer32
+
+
+VlsTenthDb ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-1"
+ STATUS current
+ DESCRIPTION
+ "This data type represents power levels (or power gain)
+ that are normally expressed in dBm (dB). Units are in tenths
+ of a dBm (db);for example, -5.1 dB will be represented as -51"
+ SYNTAX Integer32
+
+
+VlsTenthVolt ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-1"
+ STATUS current
+ DESCRIPTION
+ "This data type represents voltage levels that are normally
+ expressed in volts. Units are in tenths of a volt;
+ for example, 5.1 volts will be represented as 51."
+ SYNTAX Integer32
+
+
+VlsTvChannelType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ ""
+ SYNTAX INTEGER {
+ vlsTvChannelSkip (1),
+ vlsTvChannelAnalog (2),
+ vlsTvChannelDigital (3),
+ vlsTvChannelNoise (4)
+ }
+
+volius OBJECT IDENTIFIER ::= { enterprises 34652 }
+vlsSystem OBJECT IDENTIFIER ::= { volius 2 }
+vlsSystemGeneral OBJECT IDENTIFIER ::= { vlsSystem 10 }
+vlsNetworkServices OBJECT IDENTIFIER ::= { vlsSystem 11 }
+vlsNetworkAddress OBJECT IDENTIFIER ::= { vlsNetworkServices 5 }
+vlsHttp OBJECT IDENTIFIER ::= { vlsNetworkServices 6 }
+vlsSnmp OBJECT IDENTIFIER ::= { vlsNetworkServices 7 }
+vlsSntp OBJECT IDENTIFIER ::= { vlsNetworkServices 8 }
+vlsEventLog OBJECT IDENTIFIER ::= { vlsSystem 13 }
+vlsEdfa OBJECT IDENTIFIER ::= { volius 3 }
+vlsOpticalSwitch OBJECT IDENTIFIER ::= { volius 4 }
+vlsCatvTransmitter OBJECT IDENTIFIER ::= { volius 5 }
+vlsOpticalReceiver OBJECT IDENTIFIER ::= { volius 6 }
+
+vlsModelName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device model name"
+ ::= { vlsSystemGeneral 1 }
+
+vlsSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device serial number"
+ ::= { vlsSystemGeneral 2 }
+
+vlsFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Main firmware version (monitoring PCB)"
+ ::= { vlsSystemGeneral 3 }
+
+vlsDateAndTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current date and time, only valid when SNTP time syncronization is operational"
+ ::= { vlsSystemGeneral 4 }
+
+vlsTimeZone OBJECT-TYPE
+ SYNTAX Integer32 (-720..780)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time zone expressed in minutes relative to UTC, used when reporting date and time, including event log"
+ ::= { vlsSystemGeneral 5 }
+
+vlsCaseTemperature OBJECT-TYPE
+ SYNTAX VlsTenthCelsius
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Case temperature"
+ ::= { vlsSystemGeneral 6 }
+
+vlsSupplyVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VlsSupplyVoltageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsSystemGeneral 7 }
+
+vlsSupplyVoltageEntry OBJECT-TYPE
+ SYNTAX VlsSupplyVoltageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { vlsSupplyVoltageIndex }
+ ::= { vlsSupplyVoltageTable 1 }
+
+VlsSupplyVoltageEntry ::= SEQUENCE {
+ vlsSupplyVoltageIndex
+ Integer32,
+ vlsSupplyVoltageNominal
+ VlsMilliVolt,
+ vlsSupplyVoltageActual
+ VlsMilliVolt
+}
+
+vlsSupplyVoltageIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Power supply input number (1..2)"
+ ::= { vlsSupplyVoltageEntry 1 }
+
+vlsSupplyVoltageNominal OBJECT-TYPE
+ SYNTAX VlsMilliVolt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Nominal value of supply voltage"
+ ::= { vlsSupplyVoltageEntry 2 }
+
+vlsSupplyVoltageActual OBJECT-TYPE
+ SYNTAX VlsMilliVolt
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actually measured value of supply voltage"
+ ::= { vlsSupplyVoltageEntry 3 }
+
+vlsSupplySelectMode OBJECT-TYPE
+ SYNTAX VlsPowerSwitchMode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Mode of operation of power supply selection logic"
+ ::= { vlsSystemGeneral 8 }
+
+vlsSupplySelectedInput OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently selected power supply (1..2)"
+ ::= { vlsSystemGeneral 9 }
+
+vlsBootLoaderVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Version of the boot loader"
+ ::= { vlsSystemGeneral 10 }
+
+vlsRfFwVer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ ::= { vlsSystemGeneral 11 }
+
+vlsOperatingMinutes OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of minutes in operation"
+ ::= { vlsSystemGeneral 12 }
+
+vlsMonPcbRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ ::= { vlsSystemGeneral 14 }
+
+vlsRfPcbRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ ::= { vlsSystemGeneral 15 }
+
+vlsNumOpticalInputs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of optical inputs (1 or 2)"
+ ::= { vlsSystemGeneral 16 }
+
+vlsMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device MAC address"
+ ::= { vlsNetworkAddress 1 }
+
+vlsIpAddress OBJECT-TYPE
+ SYNTAX InetAddressIPv4
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address"
+ ::= { vlsNetworkAddress 2 }
+
+vlsNetMask OBJECT-TYPE
+ SYNTAX InetAddressIPv4
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Subnet mask"
+ ::= { vlsNetworkAddress 3 }
+
+vlsDefaultGateway OBJECT-TYPE
+ SYNTAX InetAddressIPv4
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Default gateway"
+ ::= { vlsNetworkAddress 4 }
+
+vlsDhcp OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ ::= { vlsNetworkAddress 5 }
+
+vlsHttpPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ ::= { vlsHttp 1 }
+
+vlsHttpPasswordEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable web interface password protection"
+ ::= { vlsHttp 2 }
+
+vlsHttpPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ ""
+ ::= { vlsHttp 3 }
+
+vlsHttpEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ ""
+ ::= { vlsHttp 4 }
+
+vlsSnmpPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ ""
+ ::= { vlsSnmp 1 }
+
+vlsTrapDestTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VlsTrapDestEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsSnmp 2 }
+
+vlsTrapDestEntry OBJECT-TYPE
+ SYNTAX VlsTrapDestEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { vlsTrapDestIndex }
+ ::= { vlsTrapDestTable 1 }
+
+VlsTrapDestEntry ::= SEQUENCE {
+ vlsTrapDestIndex
+ Integer32,
+ vlsTrapDestAddr
+ InetAddressIPv4,
+ vlsTrapDestPort
+ Integer32,
+ vlsTrapDestEnable
+ TruthValue
+}
+
+vlsTrapDestIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "SNMP trap destination index (1..4)"
+ ::= { vlsTrapDestEntry 1 }
+
+vlsTrapDestAddr OBJECT-TYPE
+ SYNTAX InetAddressIPv4
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP trap destination IP address"
+ ::= { vlsTrapDestEntry 2 }
+
+vlsTrapDestPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ ""
+ ::= { vlsTrapDestEntry 3 }
+
+vlsTrapDestEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable sending of SNMP traps to this destination"
+ ::= { vlsTrapDestEntry 4 }
+
+vlsSntpServerAddr OBJECT-TYPE
+ SYNTAX InetAddressIPv4
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address of the SNTP server"
+ ::= { vlsSntp 1 }
+
+vlsSntpServerPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ ""
+ ::= { vlsSntp 2 }
+
+vlsSntpEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable time synchronization with an SNTP server"
+ ::= { vlsSntp 3 }
+
+vlsLastEventCode OBJECT-TYPE
+ SYNTAX VlsEvent
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event code of the latest recorder event"
+ ::= { vlsEventLog 1 }
+
+vlsLastEventIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Sequence number of the latest recorded event"
+ ::= { vlsEventLog 2 }
+
+vlsEventLogSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of events currently recorded in the log"
+ ::= { vlsEventLog 3 }
+
+vlsEventLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VlsEventLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsEventLog 4 }
+
+vlsEventLogEntry OBJECT-TYPE
+ SYNTAX VlsEventLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { vlsEventIndex }
+ ::= { vlsEventLogTable 1 }
+
+VlsEventLogEntry ::= SEQUENCE {
+ vlsEventIndex
+ Integer32,
+ vlsEventCode
+ VlsEvent,
+ vlsEventTimeStamp
+ TimeTicks,
+ vlsEventDateTime
+ DateAndTime,
+ vlsEventMessage
+ DisplayString
+}
+
+vlsEventIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Sequence number of the event in the log entry"
+ ::= { vlsEventLogEntry 1 }
+
+vlsEventCode OBJECT-TYPE
+ SYNTAX VlsEvent
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Event code of the event in the log entry"
+ ::= { vlsEventLogEntry 2 }
+
+vlsEventTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Up time when the event in the log entry was recorded"
+ ::= { vlsEventLogEntry 3 }
+
+vlsEventDateTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Date and time when the event in the log entry was recorded. Only valid when SNTP time syncronization is operational."
+ ::= { vlsEventLogEntry 4 }
+
+vlsEventMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Message string of the event in the log entry"
+ ::= { vlsEventLogEntry 5 }
+
+vlsEventTrap NOTIFICATION-TYPE
+ OBJECTS { vlsLastEventCode }
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsEventLog 8 }
+
+vlsReceiverInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VlsReceiverInputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsOpticalReceiver 1 }
+
+vlsReceiverInputEntry OBJECT-TYPE
+ SYNTAX VlsReceiverInputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { vlsReceiverInputIndex }
+ ::= { vlsReceiverInputTable 1 }
+
+VlsReceiverInputEntry ::= SEQUENCE {
+ vlsReceiverInputIndex
+ Integer32,
+ vlsReceiverInputPower
+ VlsTenthDb
+}
+
+vlsReceiverInputIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optical input number (1..2)"
+ ::= { vlsReceiverInputEntry 1 }
+
+vlsReceiverInputPower OBJECT-TYPE
+ SYNTAX VlsTenthDb
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optical power at the input"
+ ::= { vlsReceiverInputEntry 2 }
+
+vlsReceiverSelectedInput OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently selected optical input"
+ ::= { vlsOpticalReceiver 2 }
+
+vlsReceiverRfOutputPower OBJECT-TYPE
+ SYNTAX VlsDb
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsOpticalReceiver 3 }
+
+vlsReceiverSwitchMode OBJECT-TYPE
+ SYNTAX VlsInputSwitchMode
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mode of operation of optical input selection logic"
+ ::= { vlsOpticalReceiver 4 }
+
+vlsReceiverInputLowThreshold OBJECT-TYPE
+ SYNTAX VlsTenthDb
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The low threshold of optical input power for optical input selection logic"
+ ::= { vlsOpticalReceiver 5 }
+
+vlsReceiverInputHighThreshold OBJECT-TYPE
+ SYNTAX VlsTenthDb
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The high threshold of optical input power for optical input selection logic"
+ ::= { vlsOpticalReceiver 6 }
+
+vlsReceiverManualGain OBJECT-TYPE
+ SYNTAX VlsTenthDb (-150..150)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Gain setting when AGC is off"
+ ::= { vlsOpticalReceiver 7 }
+
+vlsReceiverAgcOffset OBJECT-TYPE
+ SYNTAX VlsTenthDb (-150..150)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Gain offset when AGC is on"
+ ::= { vlsOpticalReceiver 9 }
+
+vlsReceiverAgcState OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable AGC (automatic gain control)"
+ ::= { vlsOpticalReceiver 10 }
+
+vlsReceiverCurrentGain OBJECT-TYPE
+ SYNTAX VlsTenthDb (-150..150)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current gain of the optical receiver.
+ This is adjusted automatically when AGC is on,
+ or is fixed at vlsRecieverManualGain when AGC is off."
+ ::= { vlsOpticalReceiver 11 }
+
+vlsReceiverEqualizer OBJECT-TYPE
+ SYNTAX VlsTenthDb (0..150)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output spectrum tilt adjustment"
+ ::= { vlsOpticalReceiver 12 }
+
+vlsReceiverSpectrumTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VlsReceiverSpectrumEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsOpticalReceiver 15 }
+
+vlsReceiverSpectrumEntry OBJECT-TYPE
+ SYNTAX VlsReceiverSpectrumEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { vlsReceiverSpectrumIndex }
+ ::= { vlsReceiverSpectrumTable 1 }
+
+VlsReceiverSpectrumEntry ::= SEQUENCE {
+ vlsReceiverSpectrumIndex
+ Integer32,
+ vlsCenterFrequency
+ VlsKiloHertz,
+ vlsChannelType
+ VlsTvChannelType,
+ vlsChannelLevel
+ VlsTenthDb
+}
+
+vlsReceiverSpectrumIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsReceiverSpectrumEntry 1 }
+
+vlsCenterFrequency OBJECT-TYPE
+ SYNTAX VlsKiloHertz
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsReceiverSpectrumEntry 2 }
+
+vlsChannelType OBJECT-TYPE
+ SYNTAX VlsTvChannelType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsReceiverSpectrumEntry 3 }
+
+vlsChannelLevel OBJECT-TYPE
+ SYNTAX VlsTenthDb
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { vlsReceiverSpectrumEntry 4 }
+END
+