1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
|
VOLIUS-OR-MIB DEFINITIONS ::= BEGIN
IMPORTS
NOTIFICATION-TYPE, OBJECT-TYPE, MODULE-IDENTITY,
enterprises, TimeTicks, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue, MacAddress,
DateAndTime, DisplayString
FROM SNMPv2-TC
InetAddressIPv4
FROM INET-ADDRESS-MIB;
vlsGlobalModule MODULE-IDENTITY
LAST-UPDATED "201105311534Z"
ORGANIZATION
"Volius"
CONTACT-INFO
""
DESCRIPTION
"This MIB describes all SNMP-enabled hardware produced by Volius,
such as Fiber optical receivers, Erbium-doped fiber amplifiers,
Optical switches, CATV optical transmitters."
REVISION "201105311543Z"
DESCRIPTION
"Initial version"
::= { volius 1 }
VlsDb ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This data type represents gain expressed in dB (no fractional part)."
SYNTAX Integer32
VlsEvent ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX INTEGER {
vlsEventBlinking (6),
vlsEventFirmwareUpload (7),
vlsEventStartUp (8),
vlsEventPowerSw1 (27),
vlsEventPowerSw2 (28)
}
VlsInputSwitchMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX INTEGER {
vlsForce1 (1),
vlsForce2 (2),
vlsPrefer1 (3),
vlsPrefer2 (4),
vlsAutoLatching (5)
}
VlsKiloHertz ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Data type representing frequency in units of kHz."
SYNTAX Integer32
VlsMilliVolt ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX Integer32
VlsPowerSwitchMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX INTEGER {
vlsForce1 (1),
vlsForce2 (2),
vlsAuto (3)
}
VlsTenthCelsius ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents temperature values that are normally
expressed in degrees Celsius. Units are in tenths of a degree;
for example, -5.1 degrees will be represented as -51."
SYNTAX Integer32
VlsTenthDb ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents power levels (or power gain)
that are normally expressed in dBm (dB). Units are in tenths
of a dBm (db);for example, -5.1 dB will be represented as -51"
SYNTAX Integer32
VlsTenthVolt ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents voltage levels that are normally
expressed in volts. Units are in tenths of a volt;
for example, 5.1 volts will be represented as 51."
SYNTAX Integer32
VlsTvChannelType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX INTEGER {
vlsTvChannelSkip (1),
vlsTvChannelAnalog (2),
vlsTvChannelDigital (3),
vlsTvChannelNoise (4)
}
volius OBJECT IDENTIFIER ::= { enterprises 34652 }
vlsSystem OBJECT IDENTIFIER ::= { volius 2 }
vlsSystemGeneral OBJECT IDENTIFIER ::= { vlsSystem 10 }
vlsNetworkServices OBJECT IDENTIFIER ::= { vlsSystem 11 }
vlsNetworkAddress OBJECT IDENTIFIER ::= { vlsNetworkServices 5 }
vlsHttp OBJECT IDENTIFIER ::= { vlsNetworkServices 6 }
vlsSnmp OBJECT IDENTIFIER ::= { vlsNetworkServices 7 }
vlsSntp OBJECT IDENTIFIER ::= { vlsNetworkServices 8 }
vlsEventLog OBJECT IDENTIFIER ::= { vlsSystem 13 }
vlsEdfa OBJECT IDENTIFIER ::= { volius 3 }
vlsOpticalSwitch OBJECT IDENTIFIER ::= { volius 4 }
vlsCatvTransmitter OBJECT IDENTIFIER ::= { volius 5 }
vlsOpticalReceiver OBJECT IDENTIFIER ::= { volius 6 }
vlsModelName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device model name"
::= { vlsSystemGeneral 1 }
vlsSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device serial number"
::= { vlsSystemGeneral 2 }
vlsFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Main firmware version (monitoring PCB)"
::= { vlsSystemGeneral 3 }
vlsDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current date and time, only valid when SNTP time syncronization is operational"
::= { vlsSystemGeneral 4 }
vlsTimeZone OBJECT-TYPE
SYNTAX Integer32 (-720..780)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time zone expressed in minutes relative to UTC, used when reporting date and time, including event log"
::= { vlsSystemGeneral 5 }
vlsCaseTemperature OBJECT-TYPE
SYNTAX VlsTenthCelsius
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Case temperature"
::= { vlsSystemGeneral 6 }
vlsSupplyVoltageTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlsSupplyVoltageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { vlsSystemGeneral 7 }
vlsSupplyVoltageEntry OBJECT-TYPE
SYNTAX VlsSupplyVoltageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { vlsSupplyVoltageIndex }
::= { vlsSupplyVoltageTable 1 }
VlsSupplyVoltageEntry ::= SEQUENCE {
vlsSupplyVoltageIndex
Integer32,
vlsSupplyVoltageNominal
VlsMilliVolt,
vlsSupplyVoltageActual
VlsMilliVolt
}
vlsSupplyVoltageIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power supply input number (1..2)"
::= { vlsSupplyVoltageEntry 1 }
vlsSupplyVoltageNominal OBJECT-TYPE
SYNTAX VlsMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nominal value of supply voltage"
::= { vlsSupplyVoltageEntry 2 }
vlsSupplyVoltageActual OBJECT-TYPE
SYNTAX VlsMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actually measured value of supply voltage"
::= { vlsSupplyVoltageEntry 3 }
vlsSupplySelectMode OBJECT-TYPE
SYNTAX VlsPowerSwitchMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mode of operation of power supply selection logic"
::= { vlsSystemGeneral 8 }
vlsSupplySelectedInput OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Currently selected power supply (1..2)"
::= { vlsSystemGeneral 9 }
vlsBootLoaderVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of the boot loader"
::= { vlsSystemGeneral 10 }
vlsRfFwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
""
::= { vlsSystemGeneral 11 }
vlsOperatingMinutes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of minutes in operation"
::= { vlsSystemGeneral 12 }
vlsMonPcbRevision OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
""
::= { vlsSystemGeneral 14 }
vlsRfPcbRevision OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
""
::= { vlsSystemGeneral 15 }
vlsNumOpticalInputs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of optical inputs (1 or 2)"
::= { vlsSystemGeneral 16 }
vlsMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device MAC address"
::= { vlsNetworkAddress 1 }
vlsIpAddress OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address"
::= { vlsNetworkAddress 2 }
vlsNetMask OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Subnet mask"
::= { vlsNetworkAddress 3 }
vlsDefaultGateway OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default gateway"
::= { vlsNetworkAddress 4 }
vlsDhcp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
""
::= { vlsNetworkAddress 5 }
vlsHttpPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
""
::= { vlsHttp 1 }
vlsHttpPasswordEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable web interface password protection"
::= { vlsHttp 2 }
vlsHttpPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
""
::= { vlsHttp 3 }
vlsHttpEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
""
::= { vlsHttp 4 }
vlsSnmpPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
""
::= { vlsSnmp 1 }
vlsTrapDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlsTrapDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { vlsSnmp 2 }
vlsTrapDestEntry OBJECT-TYPE
SYNTAX VlsTrapDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { vlsTrapDestIndex }
::= { vlsTrapDestTable 1 }
VlsTrapDestEntry ::= SEQUENCE {
vlsTrapDestIndex
Integer32,
vlsTrapDestAddr
InetAddressIPv4,
vlsTrapDestPort
Integer32,
vlsTrapDestEnable
TruthValue
}
vlsTrapDestIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMP trap destination index (1..4)"
::= { vlsTrapDestEntry 1 }
vlsTrapDestAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP trap destination IP address"
::= { vlsTrapDestEntry 2 }
vlsTrapDestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
""
::= { vlsTrapDestEntry 3 }
vlsTrapDestEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable sending of SNMP traps to this destination"
::= { vlsTrapDestEntry 4 }
vlsSntpServerAddr OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the SNTP server"
::= { vlsSntp 1 }
vlsSntpServerPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
""
::= { vlsSntp 2 }
vlsSntpEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable time synchronization with an SNTP server"
::= { vlsSntp 3 }
vlsLastEventCode OBJECT-TYPE
SYNTAX VlsEvent
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event code of the latest recorder event"
::= { vlsEventLog 1 }
vlsLastEventIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sequence number of the latest recorded event"
::= { vlsEventLog 2 }
vlsEventLogSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of events currently recorded in the log"
::= { vlsEventLog 3 }
vlsEventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlsEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { vlsEventLog 4 }
vlsEventLogEntry OBJECT-TYPE
SYNTAX VlsEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { vlsEventIndex }
::= { vlsEventLogTable 1 }
VlsEventLogEntry ::= SEQUENCE {
vlsEventIndex
Integer32,
vlsEventCode
VlsEvent,
vlsEventTimeStamp
TimeTicks,
vlsEventDateTime
DateAndTime,
vlsEventMessage
DisplayString
}
vlsEventIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sequence number of the event in the log entry"
::= { vlsEventLogEntry 1 }
vlsEventCode OBJECT-TYPE
SYNTAX VlsEvent
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event code of the event in the log entry"
::= { vlsEventLogEntry 2 }
vlsEventTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Up time when the event in the log entry was recorded"
::= { vlsEventLogEntry 3 }
vlsEventDateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Date and time when the event in the log entry was recorded. Only valid when SNTP time syncronization is operational."
::= { vlsEventLogEntry 4 }
vlsEventMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Message string of the event in the log entry"
::= { vlsEventLogEntry 5 }
vlsEventTrap NOTIFICATION-TYPE
OBJECTS { vlsLastEventCode }
STATUS current
DESCRIPTION
""
::= { vlsEventLog 8 }
vlsReceiverInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlsReceiverInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { vlsOpticalReceiver 1 }
vlsReceiverInputEntry OBJECT-TYPE
SYNTAX VlsReceiverInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { vlsReceiverInputIndex }
::= { vlsReceiverInputTable 1 }
VlsReceiverInputEntry ::= SEQUENCE {
vlsReceiverInputIndex
Integer32,
vlsReceiverInputPower
VlsTenthDb
}
vlsReceiverInputIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical input number (1..2)"
::= { vlsReceiverInputEntry 1 }
vlsReceiverInputPower OBJECT-TYPE
SYNTAX VlsTenthDb
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical power at the input"
::= { vlsReceiverInputEntry 2 }
vlsReceiverSelectedInput OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Currently selected optical input"
::= { vlsOpticalReceiver 2 }
vlsReceiverRfOutputPower OBJECT-TYPE
SYNTAX VlsDb
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { vlsOpticalReceiver 3 }
vlsReceiverSwitchMode OBJECT-TYPE
SYNTAX VlsInputSwitchMode
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mode of operation of optical input selection logic"
::= { vlsOpticalReceiver 4 }
vlsReceiverInputLowThreshold OBJECT-TYPE
SYNTAX VlsTenthDb
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The low threshold of optical input power for optical input selection logic"
::= { vlsOpticalReceiver 5 }
vlsReceiverInputHighThreshold OBJECT-TYPE
SYNTAX VlsTenthDb
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The high threshold of optical input power for optical input selection logic"
::= { vlsOpticalReceiver 6 }
vlsReceiverManualGain OBJECT-TYPE
SYNTAX VlsTenthDb (-150..150)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Gain setting when AGC is off"
::= { vlsOpticalReceiver 7 }
vlsReceiverAgcOffset OBJECT-TYPE
SYNTAX VlsTenthDb (-150..150)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Gain offset when AGC is on"
::= { vlsOpticalReceiver 9 }
vlsReceiverAgcState OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable AGC (automatic gain control)"
::= { vlsOpticalReceiver 10 }
vlsReceiverCurrentGain OBJECT-TYPE
SYNTAX VlsTenthDb (-150..150)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current gain of the optical receiver.
This is adjusted automatically when AGC is on,
or is fixed at vlsRecieverManualGain when AGC is off."
::= { vlsOpticalReceiver 11 }
vlsReceiverEqualizer OBJECT-TYPE
SYNTAX VlsTenthDb (0..150)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output spectrum tilt adjustment"
::= { vlsOpticalReceiver 12 }
vlsReceiverSpectrumTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlsReceiverSpectrumEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { vlsOpticalReceiver 15 }
vlsReceiverSpectrumEntry OBJECT-TYPE
SYNTAX VlsReceiverSpectrumEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { vlsReceiverSpectrumIndex }
::= { vlsReceiverSpectrumTable 1 }
VlsReceiverSpectrumEntry ::= SEQUENCE {
vlsReceiverSpectrumIndex
Integer32,
vlsCenterFrequency
VlsKiloHertz,
vlsChannelType
VlsTvChannelType,
vlsChannelLevel
VlsTenthDb
}
vlsReceiverSpectrumIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { vlsReceiverSpectrumEntry 1 }
vlsCenterFrequency OBJECT-TYPE
SYNTAX VlsKiloHertz
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { vlsReceiverSpectrumEntry 2 }
vlsChannelType OBJECT-TYPE
SYNTAX VlsTvChannelType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { vlsReceiverSpectrumEntry 3 }
vlsChannelLevel OBJECT-TYPE
SYNTAX VlsTenthDb
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { vlsReceiverSpectrumEntry 4 }
END
|