summaryrefslogtreecommitdiff
path: root/MIBS/telco-systems/binox/PRVT-STATISTICS-HISTORY-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/telco-systems/binox/PRVT-STATISTICS-HISTORY-MIB')
-rw-r--r--MIBS/telco-systems/binox/PRVT-STATISTICS-HISTORY-MIB341
1 files changed, 341 insertions, 0 deletions
diff --git a/MIBS/telco-systems/binox/PRVT-STATISTICS-HISTORY-MIB b/MIBS/telco-systems/binox/PRVT-STATISTICS-HISTORY-MIB
new file mode 100644
index 0000000..22fa5fc
--- /dev/null
+++ b/MIBS/telco-systems/binox/PRVT-STATISTICS-HISTORY-MIB
@@ -0,0 +1,341 @@
+-- *********************************************************************
+-- **
+-- ** BATM Advanced Communications.
+-- **
+-- *********************************************************************
+-- ** Filename: PRVT-STATISTICS-HISTORY-MIB.mib
+-- ** Project: T-Metro Switches.
+-- ** Purpose: Private MIB
+-- *********************************************************************
+-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
+-- WARNING:
+--
+-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
+--
+-- This file is the property of BATM Advanced Communications and contains
+-- proprietary and confidential information. This file is made
+-- available to authorized BATM customers on the express
+-- condition that neither it, nor any of the information contained
+-- therein, shall be disclosed to third parties or be used for any
+-- purpose other than to replace, modify or upgrade firmware and/or
+-- software components of BATM manufactured equipment within the
+-- authorized customer's network, and that such transfer be
+-- completed in accordance with the instructions provided by
+-- BATM. Any other use is strictly prohibited.
+--
+-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
+-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
+-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
+-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
+-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
+--
+-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
+-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
+-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
+-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
+-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
+--
+-- ----------------------------------------------------------------------------
+
+PRVT-STATISTICS-HISTORY-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ switch
+ FROM PRVT-SWITCH-MIB
+ MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
+ FROM SNMPv2-SMI
+ RowStatus, TruthValue
+ FROM SNMPv2-TC;
+
+prvtStatHistMIB MODULE-IDENTITY
+ LAST-UPDATED "201202200000Z"
+ ORGANIZATION
+ "BATM Advanced Communication"
+ CONTACT-INFO
+ "BATM/Telco Systems Support team
+ Email:
+ For North America: techsupport@telco.com
+ For North Europe: support@batm.de, info@batm.de
+ For the rest of the world: techsupport@telco.com"
+ DESCRIPTION
+ "This MIB provides functionallity similar to RMON2-MIB.
+ Instead with OIDs mib is working with XPath 1.0 strings -
+ http://www.w3.org/TR/xpath.
+ Profile tables will be initialized with currently available
+ statistics."
+ REVISION "201202200000Z"
+ DESCRIPTION
+ "Initial version"
+ ::= { switch 180 }
+
+
+prvtStatHistObjects OBJECT IDENTIFIER
+ ::= { prvtStatHistMIB 1 }
+
+prvtStatHistShutdown OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable the statistics history on the device"
+ ::= { prvtStatHistObjects 1 }
+
+prvtStatHistGetInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (10..3600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval in seconds at which history statistics
+ will be gathered. Changes of this value will take
+ effect after current interval is over."
+ ::= { prvtStatHistObjects 2 }
+
+prvtStatHistType OBJECT-TYPE
+ SYNTAX INTEGER { absolute(1), delta(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The method of sampling the selected variable.
+ Changes will take effect after current interval is over."
+ ::= { prvtStatHistObjects 3 }
+
+prvtStatHistProfileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtStatHistProfileEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Create profiles with XPath 1.0 pattern."
+ ::= { prvtStatHistObjects 4 }
+
+prvtStatHistProfileEntry OBJECT-TYPE
+ SYNTAX PrvtStatHistProfileEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in prvtStatHistProfileTable."
+ INDEX { prvtStatHistProfileName }
+ ::= { prvtStatHistProfileTable 1 }
+
+PrvtStatHistProfileEntry ::= SEQUENCE {
+ prvtStatHistProfileName OCTET STRING,
+ prvtStatHistProfileRowStatus RowStatus,
+ prvtStatHistProfileXPathTemplate OCTET STRING
+}
+
+prvtStatHistProfileName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1..128))
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Profile identifier - string with length [ 1 .. 128 ]"
+ ::= { prvtStatHistProfileEntry 1 }
+
+prvtStatHistProfileRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Create rows in prvtStatHistProfileTable."
+ ::= { prvtStatHistProfileEntry 2 }
+
+prvtStatHistProfileXPathTemplate OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1..255))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "XPath 1.0 template - contains data model path, with '{%s}' as
+ key place holder - if we have multiply keys more '%s' must
+ be added. Changes of this value will take effect
+ after current interval is over."
+ ::= { prvtStatHistProfileEntry 3 }
+
+prvtStatHistControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtStatHistControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Control table binds profile to a keys."
+ ::= { prvtStatHistObjects 5 }
+
+prvtStatHistControlEntry OBJECT-TYPE
+ SYNTAX PrvtStatHistControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in prvtStatHistControlTable."
+ INDEX { prvtStatHistControlId }
+ ::= { prvtStatHistControlTable 1 }
+
+PrvtStatHistControlEntry ::= SEQUENCE {
+ prvtStatHistControlId Unsigned32,
+ prvtStatHistControlRowStatus RowStatus,
+ prvtStatHistControlProfileName OCTET STRING,
+ prvtStatHistControlXPathKey OCTET STRING,
+ prvtStatHistControlValue OCTET STRING,
+ prvtStatHistControlFirstDataId OCTET STRING,
+ prvtStatHistControlLastDataId OCTET STRING
+}
+
+prvtStatHistControlId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..200)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Control table identifier. Number [ 1 .. 200 ] "
+ ::= { prvtStatHistControlEntry 1 }
+
+prvtStatHistControlRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Create entry in prvtStatHistControlTable.
+ Changes of this value will take effect after
+ current interval is over."
+ ::= { prvtStatHistControlEntry 2 }
+
+prvtStatHistControlProfileName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1..128))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Profile name from prvtStatHistProfileTable.
+ Changes of this value will take effect after
+ current interval is over."
+ ::= { prvtStatHistControlEntry 3 }
+
+prvtStatHistControlXPathKey OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1..255))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "XPath key is applied to profile XPath-template.
+ Changes of this value will take effect after
+ current interval is over."
+ ::= { prvtStatHistControlEntry 4 }
+
+prvtStatHistControlValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current value of the prvtStatHistControlProfileName +
+ prvtStatHistControlXPathKey or empty if get operation was unsucceful.
+ To debug the problem, enable logs."
+ ::= { prvtStatHistControlEntry 5 }
+
+prvtStatHistControlFirstDataId OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "prvtStatHistDataTable has maximum 120 elements.
+ This restriction is due to hardware limitation.
+ prvtStatHistControlFirstDataId will define first valid index
+ in prvtStatHistDataTable table thus making constantly increasing
+ prvtStatHistDataId more predicatable for management systems.
+ Value should be treated as unsigned 64 bits integer"
+ ::= { prvtStatHistControlEntry 6 }
+
+prvtStatHistControlLastDataId OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "prvtStatHistDataTable has maximum 120 elements.
+ This restriction is due to hardware limitation.
+ prvtStatHistControlLastDataId will define last valid index
+ in prvtStatHistDataTable table thus making constantly increasing
+ prvtStatHistDataId more predicatable for management systems.
+ Value should be treated as unsigned 64 bits integer"
+ ::= { prvtStatHistControlEntry 7 }
+
+prvtStatHistDataTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtStatHistDataEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A historical sample of user-defined variables. This sample
+ is associated with the prvtStatHistControlEntry that set up the
+ parameters for a regular collection of these samples.
+ The prvtStatHistControlId value in the index identifies the
+ prvtStatHistControlEntry on whose behalf this entry was created."
+ ::= { prvtStatHistObjects 6 }
+
+prvtStatHistDataEntry OBJECT-TYPE
+ SYNTAX PrvtStatHistDataEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry in prvtStatHistDataTable"
+ INDEX { prvtStatHistControlId, prvtStatHistDataId }
+ ::= { prvtStatHistDataTable 1 }
+
+PrvtStatHistDataEntry ::= SEQUENCE {
+ prvtStatHistDataId OCTET STRING,
+ prvtStatHistDataIntervalStart OCTET STRING,
+ prvtStatHistDataIntervalEnd OCTET STRING,
+ prvtStatHistDataProfile OCTET STRING,
+ prvtStatHistDataKey OCTET STRING,
+ prvtStatHistDataValue OCTET STRING,
+ prvtStatHistDataStatus INTEGER
+}
+
+prvtStatHistDataId OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index of prvtStatHistDataTable - 64 unsigned integer,
+ constantly increasing."
+ ::= { prvtStatHistDataEntry 1 }
+
+prvtStatHistDataIntervalStart OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Show when current interval has started."
+ ::= { prvtStatHistDataEntry 2 }
+
+prvtStatHistDataIntervalEnd OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Show when current interval has ended"
+ ::= { prvtStatHistDataEntry 3 }
+
+prvtStatHistDataProfile OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Profile being used"
+ ::= { prvtStatHistDataEntry 4 }
+
+prvtStatHistDataKey OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Key being used"
+ ::= { prvtStatHistDataEntry 5 }
+
+prvtStatHistDataValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Result value, 64 unsinged int"
+ ::= { prvtStatHistDataEntry 6 }
+
+prvtStatHistDataStatus OBJECT-TYPE
+ SYNTAX INTEGER { notAvailable(1), positive(2), negative(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of the operation."
+ ::= { prvtStatHistDataEntry 7 }
+
+END -- end of module PRVT-STATISTICS-HISTORY-MIB.