1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
|
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-STATISTICS-HISTORY-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-STATISTICS-HISTORY-MIB DEFINITIONS ::= BEGIN
IMPORTS
switch
FROM PRVT-SWITCH-MIB
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
RowStatus, TruthValue
FROM SNMPv2-TC;
prvtStatHistMIB MODULE-IDENTITY
LAST-UPDATED "201202200000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"This MIB provides functionallity similar to RMON2-MIB.
Instead with OIDs mib is working with XPath 1.0 strings -
http://www.w3.org/TR/xpath.
Profile tables will be initialized with currently available
statistics."
REVISION "201202200000Z"
DESCRIPTION
"Initial version"
::= { switch 180 }
prvtStatHistObjects OBJECT IDENTIFIER
::= { prvtStatHistMIB 1 }
prvtStatHistShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the statistics history on the device"
::= { prvtStatHistObjects 1 }
prvtStatHistGetInterval OBJECT-TYPE
SYNTAX Unsigned32 (10..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interval in seconds at which history statistics
will be gathered. Changes of this value will take
effect after current interval is over."
::= { prvtStatHistObjects 2 }
prvtStatHistType OBJECT-TYPE
SYNTAX INTEGER { absolute(1), delta(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The method of sampling the selected variable.
Changes will take effect after current interval is over."
::= { prvtStatHistObjects 3 }
prvtStatHistProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtStatHistProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Create profiles with XPath 1.0 pattern."
::= { prvtStatHistObjects 4 }
prvtStatHistProfileEntry OBJECT-TYPE
SYNTAX PrvtStatHistProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in prvtStatHistProfileTable."
INDEX { prvtStatHistProfileName }
::= { prvtStatHistProfileTable 1 }
PrvtStatHistProfileEntry ::= SEQUENCE {
prvtStatHistProfileName OCTET STRING,
prvtStatHistProfileRowStatus RowStatus,
prvtStatHistProfileXPathTemplate OCTET STRING
}
prvtStatHistProfileName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Profile identifier - string with length [ 1 .. 128 ]"
::= { prvtStatHistProfileEntry 1 }
prvtStatHistProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Create rows in prvtStatHistProfileTable."
::= { prvtStatHistProfileEntry 2 }
prvtStatHistProfileXPathTemplate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"XPath 1.0 template - contains data model path, with '{%s}' as
key place holder - if we have multiply keys more '%s' must
be added. Changes of this value will take effect
after current interval is over."
::= { prvtStatHistProfileEntry 3 }
prvtStatHistControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtStatHistControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Control table binds profile to a keys."
::= { prvtStatHistObjects 5 }
prvtStatHistControlEntry OBJECT-TYPE
SYNTAX PrvtStatHistControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in prvtStatHistControlTable."
INDEX { prvtStatHistControlId }
::= { prvtStatHistControlTable 1 }
PrvtStatHistControlEntry ::= SEQUENCE {
prvtStatHistControlId Unsigned32,
prvtStatHistControlRowStatus RowStatus,
prvtStatHistControlProfileName OCTET STRING,
prvtStatHistControlXPathKey OCTET STRING,
prvtStatHistControlValue OCTET STRING,
prvtStatHistControlFirstDataId OCTET STRING,
prvtStatHistControlLastDataId OCTET STRING
}
prvtStatHistControlId OBJECT-TYPE
SYNTAX Unsigned32 (1..200)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Control table identifier. Number [ 1 .. 200 ] "
::= { prvtStatHistControlEntry 1 }
prvtStatHistControlRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Create entry in prvtStatHistControlTable.
Changes of this value will take effect after
current interval is over."
::= { prvtStatHistControlEntry 2 }
prvtStatHistControlProfileName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Profile name from prvtStatHistProfileTable.
Changes of this value will take effect after
current interval is over."
::= { prvtStatHistControlEntry 3 }
prvtStatHistControlXPathKey OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"XPath key is applied to profile XPath-template.
Changes of this value will take effect after
current interval is over."
::= { prvtStatHistControlEntry 4 }
prvtStatHistControlValue OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current value of the prvtStatHistControlProfileName +
prvtStatHistControlXPathKey or empty if get operation was unsucceful.
To debug the problem, enable logs."
::= { prvtStatHistControlEntry 5 }
prvtStatHistControlFirstDataId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"prvtStatHistDataTable has maximum 120 elements.
This restriction is due to hardware limitation.
prvtStatHistControlFirstDataId will define first valid index
in prvtStatHistDataTable table thus making constantly increasing
prvtStatHistDataId more predicatable for management systems.
Value should be treated as unsigned 64 bits integer"
::= { prvtStatHistControlEntry 6 }
prvtStatHistControlLastDataId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"prvtStatHistDataTable has maximum 120 elements.
This restriction is due to hardware limitation.
prvtStatHistControlLastDataId will define last valid index
in prvtStatHistDataTable table thus making constantly increasing
prvtStatHistDataId more predicatable for management systems.
Value should be treated as unsigned 64 bits integer"
::= { prvtStatHistControlEntry 7 }
prvtStatHistDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtStatHistDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A historical sample of user-defined variables. This sample
is associated with the prvtStatHistControlEntry that set up the
parameters for a regular collection of these samples.
The prvtStatHistControlId value in the index identifies the
prvtStatHistControlEntry on whose behalf this entry was created."
::= { prvtStatHistObjects 6 }
prvtStatHistDataEntry OBJECT-TYPE
SYNTAX PrvtStatHistDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in prvtStatHistDataTable"
INDEX { prvtStatHistControlId, prvtStatHistDataId }
::= { prvtStatHistDataTable 1 }
PrvtStatHistDataEntry ::= SEQUENCE {
prvtStatHistDataId OCTET STRING,
prvtStatHistDataIntervalStart OCTET STRING,
prvtStatHistDataIntervalEnd OCTET STRING,
prvtStatHistDataProfile OCTET STRING,
prvtStatHistDataKey OCTET STRING,
prvtStatHistDataValue OCTET STRING,
prvtStatHistDataStatus INTEGER
}
prvtStatHistDataId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of prvtStatHistDataTable - 64 unsigned integer,
constantly increasing."
::= { prvtStatHistDataEntry 1 }
prvtStatHistDataIntervalStart OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show when current interval has started."
::= { prvtStatHistDataEntry 2 }
prvtStatHistDataIntervalEnd OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show when current interval has ended"
::= { prvtStatHistDataEntry 3 }
prvtStatHistDataProfile OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Profile being used"
::= { prvtStatHistDataEntry 4 }
prvtStatHistDataKey OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Key being used"
::= { prvtStatHistDataEntry 5 }
prvtStatHistDataValue OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result value, 64 unsinged int"
::= { prvtStatHistDataEntry 6 }
prvtStatHistDataStatus OBJECT-TYPE
SYNTAX INTEGER { notAvailable(1), positive(2), negative(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the operation."
::= { prvtStatHistDataEntry 7 }
END -- end of module PRVT-STATISTICS-HISTORY-MIB.
|